BFT PHOBOS BT A40 Installation Manual
BFT PHOBOS BT A40: the electromechanical piston actuator for swing gates with leaves up to 4 meters long and weighing up to 250 kg. The articulated arm simplifies and speeds up installation even on already existing gates. The BFT PHOBOS BT A40 has an adjustable opening angle up to 120 degrees and adjustable mechanical stops for opening and closing.
Advertisement
Advertisement
AUTOMAZIONI A PISTONE PER CANCELLI A BATTENTE
PISTON AUTOMATIONS FOR SWING GATES
AUTOMATIONS A PISTON POUR PORTAILS BATTANTS
ELEKTROMECHANISCHER DREHTORANTRIEB
AUTOMATIZACIONES A PISTON PARA PORTONES CON BATIENTE
AUTOMATISERINGSSYSTEMEN MET ZUIGER VOOR VLEUGELPOORTEN
Attenzione!
Leggere attentamente le “Avvertenze” all’interno! Caution! Read “Warnings” inside carefully! Attention!
Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur! Achtung!
Bitte lesen Sie aufmerksam die „Hinweise“ im Inneren! ¡Atención¡ Leer atentamente las “Advertencias” en el interior! Let op! Lees de “Waarschuwingen”tigre aan de binnenkant zorgvuldig!
INSTALLAZIONE VELOCE-QUICK INSTALLATION-INSTALLATION RAPIDE
SCHNELLINSTALLATION-INSTALACIÓN RÁPIDA - SNELLE INSTALLATIE
PREDISPOSIZIONE TUBI, TUBE ARRANGEMENT, PRÉDISPOSITION DES TUYAUX,
VORBEREITUNG DER LEITUNGEN, DISPOSICIÓN DE TUBOS,
VOORBEREIDING LEIDINGEN.
A
2
2x0,75 mm
2
2
3x1,5 mm
5x0,75 mm
3x1 mm
2
3x1 mm
2
RG58
2x1,5 mm
2
2x0,75 mm
2x1,5 mm
2
2
R
Q
2
2
3x1,5 mm
5x0,75 mm
3x1,5 mm
2
SCHEMA D’INSTALLAZIONE. INSTALLATION DIAGRAM. SCHÉMA D’INSTALLATION.
INSTALLATIONSSCHEMA. ESQUEMA DE INSTALACIÓN. INSTALLATIESCHEMA.
D
S
F
B
2S
P a
C=710 mm (PHOBOS BT
A25)
C=820 mm (PHOBOS BT
A40)
1
S
(mm)
20
30
40
50
PHOBOS BT A25 PHOBOS BT A40
125 kg (~ 1250 N) b (mm)
250 kg (~ 2500 N)
125 kg (~ 1250 N)
250 kg (~ 2500 N) b (mm)
100 ÷ 120
100 ÷ 130
100 ÷ 140
100 ÷ 150
130 ÷ 210
140 ÷ 210
150 ÷ 210
160 ÷ 210
130 ÷ 160
130 ÷ 170
130 ÷ 180
130 ÷ 190
170 ÷ 260
180 ÷ 260
190 ÷ 260
200 ÷ 260 kg
2
PHOBOS BT A25 b a 100 110 120 130 140 150 160 170
100 114 116 108 102 97
110
120
130
140
150
112 108 103 98
111 105 99 95
107 105 100 95 92
105 100 95 92
105 100 95 92
160 101 95 92 89
170 101 93 91 89
180 92 90 88
190 90 87
200 87
95
3
PHOBOS BT A40 b a 100 110 120 130 140 150 160 170 180 190 200 210 220 230
130 100 104 107 110 113 116 119 121 124 123 114 109 104 101
140 100 103 106 109 112 115 118 120 122 116 110 107 102 98
150 99 102 105 108 111 114 117 119 120 112 106 102 98 95
160 98 101 105 107 110 113 115 116 114 109 103 99 96
170 97 100 104 107 109 112 114 113 109 105 100 96 93
180 97 100 103 106 108 111 113 109 105 100 97 93
190 97 100 102 105 107 109 112 106 101 96 93
200 97 99 101 104 106 106 106 100 97 93
210 96 98 101 103 106 104 103 97 92
220 96 98 101 103 105 101 97 93
230 96 98 101 103 105 97 93
240 95 97 99 99 96 92
250 95 97 97 95 91
260 95 97 95 91
2 PHOBOS BT A25 - PHOBOS BT A40
ANCORAGGI DEGLI ATTACCHI AL PILASTRO. FASTENING OF FITTINGS TO PILLAR. ANCRAGES DES RACCORDEMENTS SUR LE PILIER. VERANKE-
RUNGEN DER ANSCCHLÜSSE AM PFEILER. ANCLAJES DE LAS FIJACIONES AL PILAR. VERANKERING VAN DE BEVESTIGINGEN AAN DE PIJLER.
* * *
C
* Non in dotazione! Not provided! Pas fournis! Nicht mitgeliefert! No incluidos en el kit! Niet meegeleverd!
CAVO DI ALIMENTAZIONE. POWER CABLE. C ÂBLE D’ALIMENTATION. NETZKABEL. CABLE DE ALIMENTACIÓN. VOEDINGSKABEL.
1 2
D
40 mm
3 x 1,5 mm
Ø=7.1÷9.6
2
MOT -
MOT +
FC
FISSAGGIO MOTORE SU ANCORAGGIO A PILASTRO.
ATTACHING MOTOR TO FASTENING ON PILLAR.
FIXATION DU MOTEUR SUR L’ANCRAGGE SUR LE PILIER.
BEFESTIGUNG DES MOTORS AUF VERANKERUNG AM PFEILER.
FIJACIÓN MOTOR EN ANCLAJE AL PILAR.
BEVESTIGING MOTOR OP VERANKERING MET PIJLER.
1
E MASSIMA INCLINAZIONE. MAXIMUM TILT.
INCLINAISON MAXIMUM. MAX. NEIGUNG.
INCLINACIÓN MÁXIMA. MAXIMUM HELLING.
2
F
+ 30 mm
- 30 mm
V1
V1
9,5
3,5
PHOBOS BT A25 - PHOBOS BT A40 - 3
CORRETTA INSTALLAZIONE. CORRECT INSTALLATION. INSTALLATION CORRECTE. RICHTIGE INSTALLATION. INSTALACIÓN CORRECTA. CORRECTE INSTALLATIE.
CHIUDI
CLOSE
FERME
ÖFFNEN
CERRAR
SLUITEN
PHOBOS BT A25
1
PHOBOS BT A40
G
100 mm
135mm
APRI
OPEN
OUVRE
SCHLIESSEN
ABRIR
OPENEN
ANCORAGGI DEGLI ATTACCHI ALL’ANTA. FASTENING OF FITTINGS TO LEAF. ANCRAGES DES RACCORDEMENTS SUR LE VANTAIL. VERANKERUN-
GEN DER ANSCHLÜSSE AM FLÜGEL. ANCLAJES DE LAS FIJACIONES A LA HOJA. VERANKERING VAN DE BEVESTIGINGEN AAN DE VLEUGEL.
H
J
* Non in dotazione! Not provided! Pas fournis!
Nicht mitgeliefert! No incluidos en el kit!
Niet meegeleverd!
I
FISSAGGIO OPERATORE SULL’ANTA,
OPERATOR ATTACHMENT ON DOOR,
FIXATION DE L’ACTIONNEUR SUR LE VANTAIL,
BEFESTIGUNG DES TRIEBS AM FLÜGEL,
FIJACIÓN OPERADOR EN LA HOJA,
BEVESTIGING BEDIENING OP DE VLEUGEL.
1
REGOLAZIONE FINECORSA DI CHIUSURA, CLOSING LIMIT DEVICE ADJUSTMENT, RÉGLAGE DES FINS
DE COURSE DE FERMETURE, VERANKERUNG DER ANSCHLÜSSE AM FLÜGEL, REGULACIÓN DEL FIN DE
CARRERA DE CIERRE, AFSTELLING AANSLAG SLUITING.
1 2
3
FC2 (CLOSE)
B CHIUDI
CLOSE
FERME
ÖFFNEN
CERRAR
SLUITEN
~5 mm
A
J
A
2 3
REGOLAZIONE FINECORSA DI APERTURA, OPENING LIMIT DEVICE
ADJUSTMENT, RÉGLAGE DE LA FIN DE COURSE D’OUVERTURE , EIN-
STELLUNG DES ÖFFNUNGS-ENDSCHALTERS, REGULACIÓN DEL FIN DE
CARRERA DE APERTURA, AFSTELLING EINDAANSLAG OPENING.
K
APRI
OPEN
OUVRE
SCHLIESSEN
ABRIR
OPENEN
~5 mm
FC1 (OPEN)
4 PHOBOS BT A25 - PHOBOS BT A40
80 a
L
850 PHOBOS BT A25
960 PHOBOS BT A40
Cu MAX 290 mm PHOBOS BT A25
Cu MAX 400 mm Phobos BT A40
110
M
72,5 mm PHOBOS BT A25
108 mm PHOBOS BT A40
N
O
1
Sinistra/Left/Gauche
Links/Izquierda
Esquerda
P
1
Destra/Right/Droite
Rechts/Derecha
Direita
1
PHOBOS BT A25 - PHOBOS BT A40 - 5
INSTALLER WARNINGS
WARNING! Important safety instructions. Carefully read and comply with all the warnings and instructions that come with the product as incorrect installation can cause injury to people and animals and damage to property.
The warnings and instructions give important information regarding safety, installation, use and maintenance. Keep hold of instructions so that you can attach them to the technical fi le and keep them handy for future reference.
GENERAL SAFETY
This product has been designed and built solely for the purpose indicated herein.
Uses other than those indicated herein might cause damage to the product and create a hazard.
- The units making up the machine and its installation must meet the requirements of the following European Directives, where applicable: 2004/108/EC, 2006/95/
EC, 2006/42/EC, 89/106/EC, 99/05/EC and later amendments. For all countries outside the EEC, it is advisable to comply with the standards mentioned, in addition to any national standards in force, to achieve a good level of safety.
- The Manufacturer of this product (hereinafter referred to as the “Firm”) disclaims all responsibility resulting from improper use or any use other than that for which the product has been designed, as indicated herein, as well as for failure to apply Good Practice in the construction of entry systems (doors, gates, etc.) and for deformation that could occur during use.
- Installation must be carried out by quali fi ed personnel (professional installer, according to EN 12635), in compliance with Good Practice and current code.
- Before installing the product, make all structural changes required to produce safety gaps and to provide protection from or isolate all crushing, shearing and dragging hazard areas and danger zones in general in accordance with the provisions of standards EN 12604 and 12453 or any local installation standards.
Check that the existing structure meets the necessary strength and stability requirements.
- Before commencing installation, check the product for damage.
- The Firm is not responsible for failure to apply Good Practice in the construction and maintenance of the doors, gates, etc. to be motorized, or for deformation that might occur during use.
- Make sure the stated temperature range is compatible with the site in which the automated system is due to be installed.
- Do not install this product in an explosive atmosphere: the presence of fl ammable fumes or gas constitutes a serious safety hazard.
- Disconnect the electricity supply before performing any work on the system.
Also disconnect bu ff er batteries, if any are connected.
- Before connecting the power supply, make sure the product’s ratings match the mains ratings and that a suitable residual current circuit breaker and overcurrent protection device have been installed upline from the electrical system. Have the automated system’s mains power supply fi tted with a switch or omnipolar thermal-magnetic circuit breaker with a contact separation that provide full disconnection under overvoltage category III conditions.
- Make sure that upline from the mains power supply there is a residual current circuit breaker that trips at no more than 0.03A as well as any other equipment required by code.
- Make sure the earth system has been installed correctly: earth all the metal parts belonging to the entry system (doors, gates, etc.) and all parts of the system featuring an earth terminal.
- Installation must be carried out using safety devices and controls that meet standards EN 12978 and EN 12453.
- Impact forces can be reduced by using deformable edges.
- In the event impact forces exceed the values laid down by the relevant standards, apply electro-sensitive or pressure-sensitive devices.
- Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of impact, crushing, dragging and shearing hazards. Bear in mind the standards and directives in force, Good Practice criteria, intended use, the installation environment, the operating logic of the system and forces generated by the automated system.
- Apply all signs required by current code to identify hazardous areas (residual risks). All installations must be visibly identi fi ed in compliance with the provisions
- of standard EN 13241-1.
Once installation is complete, apply a nameplate featuring the door/gate’s data.
- This product cannot be installed on leaves incorporating doors (unless the motor can be activated only when the door is closed).
- If the automated system is installed at a height of less than 2.5 m or is accessible, the electrical and mechanical parts must be suitably protected.
- Install any fi xed controls in a position where they will not cause a hazard, away from moving parts. More speci fi cally, hold-to-run controls must be positioned within direct sight of the part being controlled and, unless they are key operated, must be installed at a height of at least 1.5 m and in a place where they cannot be reached by the public.
- Apply at least one warning light ( fl ashing light) in a visible position, and also attach a Warning sign to the structure.
- Attach a label near the operating device, in a permanent fashion, with information on how to operate the automated system’s manual release.
- Make sure that, during operation, mechanical risks are avoided or relevant protective measures taken and, more speci fi cally, that nothing can be banged, crushed, caught or cut between the part being operated and surrounding parts.
- Once installation is complete, make sure the motor automation settings are correct and that the safety and release systems are working properly.
- Only use original spare parts for any maintenance or repair work. The Firm disclaims all responsibility for the correct operation and safety of the automated system if parts from other manufacturers are used.
- Do not make any modi fi cations to the automated system’s components unless explicitly authorized by the Firm.
- Instruct the system’s user on what residual risks may be encountered, on the control systems that have been applied and on how to open the system manually in an emergency. give the user guide to the end user.
- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accordance with the provisions of the laws in force. Keep nylon bags and polystyrene out of reach of children.
WIRING
WARNING! For connection to the mains power supply, use: a multicore cable with a cross-sectional area of at least 5x1.5mm
2 or 4x1.5mm
2 when dealing with threephase power supplies or 3x1.5mm
2 for single-phase supplies (by way of example, type H05 VV-F cable can be used with a cross-sectional area of 4x1.5mm
2 ). To connect auxiliary equipment, use wires with a cross-sectional area of at least 0.5 mm 2 .
- Only use pushbuttons with a capacity of 10A-250V or more.
- Wires must be secured with additional fastening near the terminals (for example, using cable clamps) in order to keep live parts well separated from safety extra low voltage parts.
- During installation, the power cable must be stripped to allow the earth wire to be connected to the relevant terminal, while leaving the live wires as short as possible. The earth wire must be the last to be pulled taut in the event the cable’s fastening device comes loose.
WARNING!
safety extra low voltage wires must be kept physically separate from low voltage wires.
Only quali fi ed personnel (professional installer) should be allowed to access live parts.
CHECKING THE AUTOMATED SYSTEM AND MAINTENANCE
Before the automated system is fi nally put into operation, and during maintenance work, perform the following checks meticulously:
- Make sure all components are fastened securely.
- Check starting and stopping operations in the case of manual control.
- Check the logic for normal or personalized operation.
- For sliding gates only: check that the rack and pinion mesh correctly with 2 mm of play along the full length of the rack; keep the track the gate slides on clean and free of debris at all times.
- For sliding gates and doors only: make sure the gate’s running track is straight and horizontal and that the wheels are strong enough to take the weight of the gate.
- For cantilever sliding gates only: make sure there is no dipping or swinging during operation.
- For swing gates only: make sure the leaves’ axis of rotation is perfectly vertical.
-For barriers only: before opening the door, the spring must be decompressed
(vertical boom).
- Check that all safety devices (photocells, safety edges, etc.) are working properly and that the anti-crush safety device is set correctly, making sure that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
- Impact forces can be reduced by using deformable edges.
- Make sure that the emergency operation works, where this feature is provided.
- Check opening and closing operations with the control devices applied.
- Check that electrical connections and cabling are intact, making extra sure that insulating sheaths and cable glands are undamaged.
- While performing maintenance, clean the photocells’ optics.
- When the automated system is out of service for any length of time, activate the emergency release (see “EMERGENCY OPERATION” section) so that the operated part is made idle, thus allowing the gate to be opened and closed manually.
- If the power cord is damaged, it must be replaced by the manufacturer or their technical assistance department or other such quali fi ed person to avoid any risk .
- If “D” type devices are installed (as de fi ned by EN12453), connect in unveri fi ed mode, foresee mandatory maintenance at least every six months
- The maintenance described above must be repeated at least once yearly or at shorter intervals where site or installation conditions make this necessary.
WARNING!
Remember that the drive is designed to make the gate/door easier to use and will not solve problems as a result of defective or poorly performed installation or lack of maintenance
SCRAPPING
Materials must be disposed of in accordance with the regulations in force. Do not throw away your discarded equipment or used batteries with household waste. You are responsible for taking all your waste electrical and electronic equipment to a suitable recycling centre.
DISMANTLING
If the automated system is being dismantled in order to be reassembled at another site, you are required to:
- Cut o ff the power and disconnect the whole electrical system.
- Remove the actuator from the base it is mounted on.
- Remove all the installation’s components.
- See to the replacement of any components that cannot be removed or happen to be damaged.
THE DECLARATION OF CONFORMITY CAN BE VIEWED ON THIS WEBSITE:
WWW.BFT.IT IN THE PRODUCT SECTION.
Anything that is not explicitly provided for in the installation manual is not allowed. The operator’s proper operation can only be guaranteed if the information given is complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein.
While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those changes deemed opportune to improve the product from a technical, design or commercial point of view, and will not be required to update this publication accordingly.
8 PHOBOS BT A25 - PHOBOS BT A40
AVVERTENZE PER L’INSTALLATORE D811766_12
3) TECHNICAL SPECIFICATIONS
Power supply 24V
Max. Absorbed power
Absorbed current
40 W
1,5 A
Push and pull force
Stem speed
Impact reaction
Limit devices
2500 N (~250 kg)
15 mm/s approx.
Torque limiter aboard control board
Magnetic, incorporated and adjustable
Manual manoeuvre
Environmental conditions
Type of use
Maximum leaf length without electric lock
Maximum leaf length with electric lock
Max. leaf weight
Personalized release key
- 20°C a +55°C semi-intensive
2 m PHOBOS BT A25
3 m PHOBOS BT A40
2,5 m PHOBOS BT A25
4 m PHOBOS BT A40
4000 N (~400 kg) PHOBOS BT A25
Protection level
Controller weight
Dimensions
Lubrication
5000 N (~500 kg) PHOBOS BT A40
IP X4
50N (~5kg) PHOBOS BT A25
77N (~7,7kg) PHOBOS BT A40
See Fig. L permanent grease
MAXIMUM LENGTH/DOOR WEIGHT
WEIGHT [kg]
INSTALLATION MANUAL
2) GENERAL INFORMATION
Electromechanical operator designed to automate residential-type gates.
The gearmotor keeps the gate locked on closing and on opening, without needing an electric lock for leaves up to 3 m long.
The operator is provided with an electronic torque limiter. It must be controlled by an electronic control panel provided with torque setting.
The end-of-stroke operation is controlled by two magnetic limit devices.
The operator is provided with an obstacle detection system complying with
EN12453 and EN 12445 standards.
The following optional accessories are available on request:
- Bu ff er battery kit mod. BT BAT
Allows operation of the automation even when there is no mains power supply for a short period of time.
6) PILLAR FASTENINGS INSTALLATION DISTANCES Fig. B Rif. 2-3
6.1) How to read the installation distance tables
Select “a” and “b” according to the angle in degrees α ° that the gate has to open.
The optimum “a” and “b” values for 92° opening at constant speed are highlighted.
If there is too large a di ff erence between “a” and “b”, the leaf will not travel smoothly and the pushing or pulling force will fl uctuate during its stroke.
To respect the opening speed and ensure the controller operates correctly, it is best to keep the di ff erence between “a” and “b” as low as possible.
The table has been worked out for a 40 mm (PHOBOS BT A40), 20 mm (PHO-
BOS BT A25) thick medium-size gate. Always check that there is no possible collision between the gate and the operator.
7) FASTENING OF FITTINGS TO PILLAR Fig. C
8) POWER CABLE Fig. D
The board power supply cable must be of the H 05 RN-F type or equivalent.
The equivalent cable must guarantee:
- permanent outside use
- maximum temperature on the cable surface of +50° C
- minimum temperature of -25° C
If the motor vibrates but does not rotate, the problem may be:
- Incorrect wiring (see wiring diagram)
- If the leaf moves in the wrong direction, swap over the motor’s start connections in the control unit.
The fi rst command following a mains power outage should be open STOP
LEAVES.
9) ATTACHING MOTOR TO FASTENING ON PILLAR Fig. E
10) MAXIMUM TILT Fig. F
11) CORRECT INSTALLATION Fig. G
Correct installation entails maintaining a rod stroke margin of approx. 5-10 mm to avoid possible trouble with operation.
IMPORTANT: THE FRONT BRACKET MUST BE FITTED WITH THE SLOTS
FACING UP ( FIG.G RIF.1
) .
12) FASTENING OF FITTINGS TO LEAF Fig. H
IMPORTANT: the front bracket must be fi tted with the slots facing up (Fig. G
Ref. 1). Line up the front and rear brackets as shown in Fig. H Ref. J.
13) OPERATOR ATTACHMENT ON DOOR Fig. I
14) CLOSING LIMIT DEVICE ADJUSTMENT Fig. J
ATTENTION! To avoid braking the limit switch cable, tighten screw A keeping the wire B well tightened (as shown in Fig. J Rif. 3).
15) OPENING LIMIT DEVICE ADJUSTMENT (Fig. K)
16) DIMENSIONS Fig. L
17) TIPS FOR SPECIAL INSTALLATIONS Fig. M, N, O.
With the leaf fully open, create a recess to accommodate the operator.
Fig. M gives the minimum dimensions of the recess for the various PHOBOS
BT A25 - PHOBOS BT A40 models.
If distance “b” is greater than the values given in the installation tables:
- create a recess in the pillar Fig. N
- move the leaf so that it is fl ush with the pillar Fig. O .
18) LEAF STOPS AT GROUND LEVEL
For the actuator to work properly, it is advisable to use stops “Fig. P Rif. 1” to stop the leaves both when they are open and closed, as illustrated in Fig. P .
The leaf stops must prevent the actuator rod from reaching the end of its travel.
19) MANUAL OPENING ( See USER GUIDE -FIG.Y-).
20) ELECTRIC LOCK
WARNING: In the case of leaves longer than 3m, it is indispensable to install a solenoid latch.
For electric lock connection, the optional board is required (refer to the appropriate instruction).
Phobos BT A40 Phobos BT A25
4) TUBE ARRANGEMENT Fig. A
Install the electrical system referring to the standards in force for electrical systems CEI 64-8, IEC 364, harmonization document HD 384 and other national standards.
5) INSTALLATION DIAGRAM Fig. B
P rear bracket fastening to pillar
F front fork fastening leaf a-b distances for determining bracket “P” fastening point
C value of fastening centre-to-centre distance
D gate length
X distance from gate axis to corner of pillar
S half door thickness
Z value always greater than 45 mm (b - X) kg max. weight of leaf
α ° leaf opening angle
PHOBOS BT A25 - PHOBOS BT A40 - 9
MANUALE D’USO: MANOVRA DI EMERGENZA / USER GUIDE:EMERGENCY OPERATION-
MANUEL D’UTILISATION: DE LA MANŒUVRE D’URGENCE / BEDIENUNGSHANDBUCH: NOTFALLMANÖVER-
MANUAL DE USO: MANIOBRA DE EMERGENCIA / GEBRUIKERSHANDLEIDING: NOODMANOEUVRE
FIG. Y
Senza Elettroserratura, Without electric lock, Sans serrure électrique, Ohne Elektroschloß, Sin electrocerradura, Zonder elektrische sluiting.
1
max.18
0°
2
ON ON
OFF
3
Con Elettroserratura, With electric lock, Avec serrure électrique, Mit Elektroschloß, Con electrocerradura, Met elektrische sluiting.
1 2
max.18
0°
3
ON ON
OFF
4
18 PHOBOS BT A25 - PHOBOS BT A40
and damage to property. Keep the instructions for future reference and hand them on to any new users.
This product is meant to be used only for the purpose for which it was explicitly installed.
Any other use constitutes improper use and, consequently, is hazardous. The manufacturer cannot be held liable for any damage as a result of improper, incorrect or unreasonable use.
GENERAL SAFETY
Thank you for choosing this product. The Firm is con fi dent that its performance will meet your operating needs.
This product meets recognized technical standards and complies with safety provisions when installed correctly by quali fi ed, expert personnel (professional installer).
If installed and used correctly, the automated system will meet operating safety standards. Nonetheless, it is advisable to observe certain rules of behaviour so that accidental problems can be avoided:
- Keep adults, children and property out of range of the automated system, especially while it is moving.
- Do not allow children to play or stand within range of the automated system.
- This automated system is not meant for use by children or by people with impaired mental, physical or sensory capacities, or people who do not have suitable knowledge, unless a person who is responsible for their safety provides them with necessary supervision or instructions on how to use the device.
- Children must be supervised to ensure they do not play with the device. Do not allow children to play with the fi xed controls. Keep remote controls out of reach of children.
- Do not work near hinges or moving mechanical parts.
- Do not hinder the leaf’s movement and do not attempt to open the door manually unless the actuator has been released with the relevant release knob.
- Keep out of range of the motorized door or gate while they are moving.
- Keep remote controls or other control devices out of reach of children in order to avoid the automated system being operated inadvertently.
- The manual release’s activation could result in uncontrolled door movements if there are mechanical faults or loss of balance.
- When using roller shutter openers: keep an eye on the roller shutter while it is moving and keep people away until it has closed completely. Exercise care when activating the release, if such a device is fi tted, as an open shutter could drop quickly in the event of wear or breakage.
- The breakage or wear of any mechanical parts of the door (operated part), such as cables, springs, supports, hinges, guides…, may generate a hazard.
Have the system checked by quali fi ed, expert personnel (professional installer) at regular intervals according to the instructions issued by the installer or manufacturer of the door.
- When cleaning the outside, always cut o ff mains power.
system; do not attempt to repair or perform any other work to rectify the fault yourself and instead call in quali
(professional installer).
Materials must be disposed of in accordance with the regulations in force. Do not throw away your discarded equipment or used batteries with household waste. You are responsible for taking all your waste electrical and electronic equipment to a suitable recycling centre.
fi ed, expert personnel (professional installer) to perform the necessary repairs or maintenance. To allow access, activate the emergency release (where fi tted).
- If any part of the automated system requires direct work of any kind that is not contemplated herein, employ the services of quali fi ed, expert personnel
- At least once a year, have the automated system, and especially all safety devices, checked by quali fi ed, expert personnel (professional installer) to make sure that it is undamaged and working properly.
- A record must be made of any installation, maintenance and repair work and the relevant documentation kept and made available to the user on request.
- Failure to comply with the above may result in hazardous situations.
SCRAPPING user guide is not allowed. The operator’s proper operation can only be guaranteed if the instrucshall not be answerable for damage caused by herein.
features, the Firm reserves the right, at any time, improve the product from a technical, design or
AVERTISSEMENTS POUR L’UTILISATEUR (F)
ATTENTION : pour votre sécurité, après l’activation sition complètement ouvert ou complètement fermé, véri
éventuels. fi ez cette position du vantail avant l’automatisation. tes. Veuillez lire et suivre attentivement tous les avec le produit sachant qu’un usage incorrect aux animaux ou aux biens. Veuillez conserver et pour les transmettre aux propriétaires futurs
Cet appareil ne peut être destiné qu’à l’usage autre usage sera considéré comme impropre et
- Keep the photocells’ optics and illuminating indicator devices clean. Check that no branches or shrubs interfere with the safety devices.
- Do not use the automated system if it is in need of repair. In the event the automated system breaks down or malfunctions, cut o ff mains power to the
20 PHOBOS BT A25 - PHOBOS BT A40 cas considéré comme responsable des préjudices dus à un usage impropre, erroné ou déraisonné.
SECURITE GÉNÉRALE
Nous vous remercions d’avoir choisi ce produit qui, nous n’en doutons pas, saura vous garantir les performances attendues.
Ce produit, correctement installé par du personnel
AVVERTENZE PER L’UTILIZZATORE_05
Download
Advertisement