Design LED 60 Strip User Manual


Add to my manuals
36 Pages

advertisement

Design LED 60 Strip User Manual | Manualzz

Rev. 01/29/07

Design LED 60 Strip

Elation Professional™

4295 Charter Street

Los Angeles, Ca 90058 www.elationlighting.com

DESIGN LED 60 Strip™

©Elation Professional, Los Angeles Ca. 1 www.ElationLighting.com

TABLE OF CONTENS

DESIGN LED 60 Strip™

CONTENTS

b. Unpacking………………………………………………………..…………..… 3

6. Mounting and Installation………………………………………………………….……. 11 c. 3-Pin to 5-Pin Conversion………………………………………………………. 17 a. DMX Mode Selection……………………………………………………………. 19 d. DMX Dipswitch Reference Chart……………………………………………… 29

10. Cleaning and Maintenance……………………………………………………………… 30

11. Warranty…………………………………………………………………………………... 31

12. Photometric Data………………………………………………………………………… 33

15. Technical Specifications…………………………………………...………….………… 36

©Elation Professional, Los Angeles Ca. 2 www.ElationLighting.com

DESIGN LED 60 Strip™

1. GENERAL INFORMATION

INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today! The Design LED 60 Strip,™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.

UNPACKING: Thank you for purchasing the Design LED 60 Strip™ by Elation Professional®.

Every Design LED 60 Strip™ has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for damage and be sure all accessories necessary to operate the fixture have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this unit to your dealer without first contacting customer support at the number listed below.

Inside the box you should find: the fixture, a DMX XLR cable, an IEC power cable, an IEC

“jumper” power cable, a safety cable, and this manual. Please contact customer support at the number listed below if any of the above items are missing.

CUSTOMER SUPPORT: Elation Professional

®

provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service related issue please contact Elation Professional

®

.

Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacific Standard Time.

E-mail: [email protected]

Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to

©Elation Professional, Los Angeles Ca. 3 www.ElationLighting.com

DESIGN LED 60 Strip™ rain or moisture.

Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself. Doing so will void your manufactures warranty.

Please do not discard the shipping carton in the trash. Please recycle whenever possible.

WARRANTY REGISTRATION: The Design LED 60 Strip™ carries a two year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper and included in the shipping container.

If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without a R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain a R.A. number by contacting customer support at (323) 582-3322.

©Elation Professional, Los Angeles Ca. 4 www.ElationLighting.com

DESIGN LED 60 Strip™

2. SAFETY INSTRUCTIONS

To guarantee proper and consistent operation, it is important to follow the guidelines in this manual. Elation Professional will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.

1. Always be sure that the fan and the air inlets remain clean and are never blocked.

Allow about 6” (15cm) between this fixture and other devices or a wall to allow for proper cooling.

2. Never touch the fixture during normal operation.

3. Never look directly into the lamp beam. You risk injury to your retina, which may induce blindness.

4. For safe operation, follow the Installation guide described in chapter two of this manual. Operating the Design LED 60 Strip™ without suited safety aids such as safety cables or clamps can increase the risk of damage and/or personal injury.

5. Installation should only be performed by qualified and certified personal.

6. When mounting this fixture, use only the original rigging points included with this fixture. Any structural modification will void the original manufactures warranty and may increase the risk of damage and/or personal injury.

7. To reduce the risk of fire or shock, do not expose this fixture to rain or moisture.

8. Do not attempt to operate this fixture if the power cord has become damaged or frayed.

9. Never open this fixture while in use.

10. This device falls under protection-class I. Therefore it is essential that the device be grounded properly.

11. All electrical connections must performed by qualified personal.

12. Be sure the available voltage matches the voltage requirements of the unit. Be sure the power cord is never crimped or damaged. If the power cord is damaged,

©Elation Professional, Los Angeles Ca. 5 www.ElationLighting.com

DESIGN LED 60 Strip™ replace it immediately with a new one of similar power rating.

13. Always disconnect from main power before performing any type of service or any cleaning procedure.

14. Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord.

15. Please be aware that damages caused by modifications to the device are

not subject to warranty.

Important Notice: Damages resulting from the disregard of safety and general user instructions found in this user manual are not subject to any warranty claims.

Never touch the device during operation!

The housing may heat up

Never look directl y into the light source, as sensitive persons may suffer an epileptic shock.

©Elation Professional, Los Angeles Ca. 6 www.ElationLighting.com

3. FEATURES

• Low power consumption

• Minimal heat emission

• Maintenance free operation

• Equipped with 60 one-watt LEDs: (20 red, 20 green, 20 blue)

• High power LEDs manufactured by Lumileds, USA

• Step-less RGB color changing

• USITT DMX-512 complaint

• Preprogrammed colored macros

• Strobe-effect with a maximum flash rate of 18fps

• 8 built-in programs accessed via DMX-controller or manually

• Sound-controlled via built-in microphone

• Individual control over each LED

• Three DMX Modes:

60 DMX-channel

15 DMX-channel

6 DMX-channel

• Flicker-free operation for television and film

• Compact design: fits in 12” box truss

• Brilliant light output

DESIGN LED 60 Strip™

©Elation Professional, Los Angeles Ca. 7 www.ElationLighting.com

DESIGN LED 60 Strip™

4. GENERAL GUIDELINES

This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, and other types of architectural installations. Do not attempt operation or installation without a proper knowledge on how to do so.

This fixture was designed for indoor use only; use of this fixture outside will void the manufacture’s warranty.

Consistent operational breaks will ensure that the fixture will function properly for many years to come.

Do not shake the fixture around. Avoid brute force when installing or operating the fixture.

While choosing an installation location, please be sure that the fixture will not be exposed to extreme heat, moisture, or dust. The minimum distance between the fixture and a wall or flat surface should be at least .5 meter (about 1.5ft).

Always install the fixture with an appropriately rated safety cable. When installing the fixture in a suspended environment always be sure to use mounting hardware no less than M10 x 25 mm, also be sure the hardware is only inserted in the yoke’s mounting holes.

Do not attempt to operate this fixture until you have familiarized yourself with all of its functions.

Do not permit operation by persons not qualified for operating this type of theatrical fixture.

Most damages are the result of improper operation.

Please use the original packaging to transport the fixture in for service.

For your own safety, please read this user manual carefully before installing the device.

©Elation Professional, Los Angeles Ca. 8 www.ElationLighting.com

5. FIXTURE OVERVIEW

DESIGN LED 60 Strip™

1. Bracket Locking Knob – This knob is used to secure the bracket in place after angle adjustments have been made. output.

3. LED Assembly – RGB LED assembly 3x1watt LEDs

4. DMX Input Jack – This jack accepts an incoming DMX signal via a male, 3-pin XLR jack.

5. DMX Output Jack – This jack is used to send an incoming DMX signal to the next fixture in the DMX chain via a female, 3-pin XLR jack.

6. Power Output Jack – Use this jack to jump power to another Design LED 60 Strip.™

7. Power Input/Fuse Holder Assembly – This assembly holds the safety fuse as well as provides a female IEC connector for a power cord. Always replace the fuse with an

©Elation Professional, Los Angeles Ca. 9 www.ElationLighting.com

DESIGN LED 60 Strip™ exact match unless otherwise specified by an authorized Elation Service Technician.

Using a fuse other than that specified could seriously damage the unit and will void your manufactures warranty.

8. On/Off Power Switch – Controls main power to the unit. master–slave settings, and other special functions. See the dipswitch chart on page

16 for more information on the dipswitch functions.

10. Hanging Bracket – The unit uses a unique sectional bracket that allows the unit to be hung, mounted, or stood straight up.

11. Eye-Bolt – Use this bold as a safety-cable rigging point. Always secure any installation with a properly rated safety-cable.

©Elation Professional, Los Angeles Ca. 10 www.ElationLighting.com

DESIGN LED 60 Strip™

6. MOUNTING AND INSTALLATION

Yoke Assembly – Single Unit Operation (DLED 12 Brick shown for illustration

purposesonly). The device can be placed directly on the stage floor or rigged in any orientation on a truss without altering its operation characteristics. When connecting the hanging yoke to the fixture, refer to the illustration below.

Cautions:

For added protection mount the fixtures in areas outside walking paths, seating areas, and away from areas were the fixture might be reached by unauthorized personal.

Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight.

Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.

To avoid injury, never stand directly below the device when mounting, removing, or servicing the fixture.

Mounting points

Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217 for proper installation in Europe To ensure proper installation, only

qualified staff should attempt installation.

©Elation Professional, Los Angeles Ca. 11 www.ElationLighting.com

DESIGN LED 60 Strip™

Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.

Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet.

Mounting

The Design LED 60 Strip™ is fully operational in three different mounting positions, hanging upside-down from a ceiling, side mounted, or set on a flat level surface. Be sure this fixture is kept at least 0.5m away from any flammable materials (decoration etc.). When clamp mounting; always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure. See the image below.

©Elation Professional, Los Angeles Ca. 12 www.ElationLighting.com

DESIGN LED 60 Strip™

Clamp Mounting

CAUTION!

Be sure all electrical connections are performed by a qualified

electrician before attempting any operation.

The Design LED 60 Strip™ provides a unique mounting bracket assembly that allows the unit to stand on flat surface, hang on truss via a clamp, or be used in cluster allow multiple units to rigged together (see the illustration below). Regardless of the mounting option you choose please refer to the safety guidelines in this manual to avoid damage to the unit and/or injury to persons.

When mounting this fixture to truss be sure to secure an appropriately rated clamp to the hanging yoke using a M10 screw fitted through the center hole of the hanging yoke. As an added safety measure be sure to attach at least one properly rated safety cable to the fixture.

©Elation Professional, Los Angeles Ca. 13 www.ElationLighting.com

See illustration below.

DESIGN LED 60 Strip™

Securing the Design LED 60 Strip™

Always secure your fixture with a safety cable when suspend-ing the unit from truss or other means. The fixture provides a built-in rigging point for a safety cable as illustrated above. Be sure to only use the designated rigging point for a safety cable. Never secure a safety cable to the hanging bracket.

©Elation Professional, Los Angeles Ca. 14 www.ElationLighting.com

DESIGN LED 60 Strip™

7. UNDERSTANDING DMX

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation):

Your fixture and your DMX controller require a standard 3-pin XLR connector for data input and data output (see figure below). Be sure to only use properly rated DMX cables for DMX operation and not standrd audio cables. If you are constructing your own cables be sure to use two conductor shielded digital cable rated at a 120 ohms (this cable can be purchased at almost all professional sound and lighting stores). Your cables should be made with a male and female 3-pin XLR connector on either end of the cable.

Please note: This is not the same as audio microphone cable. Audio cable has a

different resistance rating

Be sure to follow the above figure when making your own cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.

DMX-512 control connection

Connect the provided DMX XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-pin XLR input of the moving head (Please refer to the diagram below.). You can chain multiple moving heads together through serial linking. The cable needed should be two conductor, shielded cable with XLR input and output connectors.

©Elation Professional, Los Angeles Ca. 15 www.ElationLighting.com

DESIGN LED 60 Strip™

Always be sure daisy chain your in and out data connections, never split or “Y” your DMX connections unless you are using an approved DMX splitter such as the Elation Opto Branch

4™ or DMX Branch/4™.

DMX-512 connection with DMX terminator

When longer runs of cable are used, you may need to use a terminator on the last fixture to avoid erratic behavior. A terminator is a 120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line. Using a cable terminator (Elation part number Z-DMX/T) will decrease the possibilities of erratic behavior.

5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart on the next page details a proper cable conversion.

©Elation Professional, Los Angeles Ca. 16 www.ElationLighting.com

DESIGN LED 60 Strip™

Understanding Fixture DMX addressing;

All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting DMX address is achieved by combining various dipswitches located on the rear of the fixture.

You can set the same starting address for all fixtures, or a group of fixtures, or set different address for each individual fixture. Be advised that setting all you fixtures to the same DMX address will subsequently control all fixtures in the same fashion, in other words, changing the settings of one channel will affect all the fixtures simultaneously.

If you set each fixture to a different DMX address, each unit will start to “listen” to the channel number you have set, based on the quantity of control channels (DMX channels) of each fixture. That means changing the settings of one channel will only affect the selected fixture.

In the case of the Design LED 60 Strip™, which is a 15 channel fixture (default), you

©Elation Professional, Los Angeles Ca. 17 www.ElationLighting.com

DESIGN LED 60 Strip™ should set the starting DMX address of the first unit to 1, the second unit to 16 (15 + 1),

the third unit to 31 (15 + 16), and so on. The chart on page 24 details the proper starting

DMX address dipswitch setting combination.

NOTE: The Design LED 60 Strip contains a total of 12 dipswitches. Only use dipswitches 1~9 to set the DMX address. Dipswitches 10~12 are used for special functions that will be explained on the next page.

8. OPERATING MODES

This fixture can run in three different DMX modes. The chart below describes how to access the different DMX modes. The chart below also defines the how the channel will function in the different DMX modes.

DMX

Operation mode

DIP

#12

DIP

#11

LED control Mode LEDs control channels

Preset programs channel

Strobe channel

Master dimming/ program speed

15CH

12CH

6CH

OFF OFF Each Led can be run individually

OFF ON Each Led can be run individually

ON OFF R, G, B run by group

1~12 13 14 15

1~12

1~3 4 5 6

Dipswitches 11 & 12: DMX Mode Selection, See the chart above; 15, 12, or 6 channel modes.

Dipswitch 10: Sound-active operation when used as a single stand-alone unit or

“master” unit.

Manual Settings: The chart bellows details the dipswitch setting for various manual settings.

Refer to the chart on page 20 for specific static color settings and internal program access.

Operating

Mode:

Dip

# 11

Dip

#10

Dip

#9

Dip

#8

Dip

#7

Dip

#6

Dip

#5

Dip

#4

Dip

#3

Dip

#2

Dip

#1

©Elation Professional, Los Angeles Ca. 18 www.ElationLighting.com

DESIGN LED 60 Strip™

No function OFF OFF N/A N/A N/A N/A N/A N/A N/A N/A N/A

Sound control-Stand

Alone

Static R, G, B

(Refer to

Table 3)

Preset

Program 1

OFF ON N/A N/A N/A N/A N/A N/A N/A N/A N/A

ON OFF N/A N/A

Speed

Blue Red Red

ON OFF OFF OFF OFF OFF ON

Preset

Program 2

Preset

Program 3

Preset

Program 4

Preset

Program 5

Preset

Program 6

Preset

Program 7

Preset

Program 8

ON OFF ON OFF OFF OFF OFF ON OFF

ON OFF ON OFF OFF OFF ON OFF OFF

ON OFF ON OFF OFF ON OFF OFF

ON OFF ON OFF ON OFF OFF OFF

ON OFF ON ON OFF OFF OFF OFF OFF

ON OFF ON OFF OFF OFF OFF ON ON

ON OFF ON OFF OFF OFF ON OFF ON

Manual static color settings are achieved when dipswitch 7 is in the “off” position.

RED:

Dipswitch 1 & 2 off, the red value is 0

Dipswitch 1 is on and dipswitch 2 is off, the red value is 60

Dipswitch 1 is off and dipswitch 2 is on, the red value is 125

Dipswitch 1 is on and dipswitch 2 is on, the red value is 255

GREEN:

Dipswitch 3 & 4 off, the green value is 0

Dipswitch 3 is on and dipswitch 4 is off, the green value is 60

Dipswitch 3 is off and dipswitch 4 is on, the green value is 125

Dipswitch 3 is on and dipswitch 4 is on, the green value is 255

©Elation Professional, Los Angeles Ca. 19 www.ElationLighting.com

DESIGN LED 60 Strip™

BLUE:

Dipswitch 5 & 6 is off, the blue value is 0

Dipswitch 5 is on and dipswitch 6 is off, the blue value is 60

Dipswitch 5 is off and dipswitch 6 is on, the blue value is 125

Dipswitch 5 is on and dipswitch 6 is on, the blue value is 255

When dipswitch 7 is on you can run the internal program

Dipswitches 1 & 7 on accesses internal program 1

Dipswitches 2 & 7 on accesses internal program 2

Dipswitches 3 & 7 on accesses internal program 3

Dipswitches 4 & 7 on accesses internal program 4

Dipswitches 5 & 7 on accesses internal program 5

Dipswitch 6 & 7 on accesses internal program 6

Dipswitch 1,2 & 7 on accesses internal program 7

Dipswitch 1,3 & 7 on accesses internal program 8

The chart below details the different speed settings available for the internal programs when the fixture is running in manual mode.

Dipswitch # 10 is OFF, Dipswitch #11 is ON, and Dipswitch #7 is ON, the fixture will run the internal programs;

The program speed can be adjusted by following the chart below for Dipswitch #8 and

Dipswitch #9

Slow (1.1s between scenes)

Medium (0.6s between scenes)

Fast (0.2s between scenes)

Very fast (0.1s between scenes)

DMX Operation Notes:

OFF

ON

OFF

ON

OFF

OFF

ON

ON

The fixture will function in DMX mode whenever the unit is receiving a DMX signal. Please note that this will override all manual settings regardless of dipswitch positions.

©Elation Professional, Los Angeles Ca. 20 www.ElationLighting.com

DESIGN LED 60 Strip™

This unit will keep and retain the last DMX command in the event of DMX signal failure. To reset the fixture you must turn the power off.

©Elation Professional, Los Angeles Ca. 21 www.ElationLighting.com

DESIGN LED 60 Strip™

9. DMX CHANNEL TRAITS

6 Channel Mode: This chart details a simple layout of the DMX channel assignment in

6-channel mode. The chart traits will vary slightly for 12 channel and 15-channel operation, as those modes use more RGB channels for more precise control.

CHANNEL 1:Red

CHANNEL 2:Green

CHANNEL 3:Blue

CHANNEL 4: Internal programs:

CHANNEL 5:Strobe

CHANNEL 6: Dimming (0%-100%)

©Elation Professional, Los Angeles Ca. 22 www.ElationLighting.com

DMX channel’s functions and their values (6 Channel Mode):

Channel 1 - Red:

0-255 Red (0-Black, 255-100% Red)

Channel 2 - Green:

0-255 Green (0-Black, 255- 100% Green)

Channel 3 - Blue:

221-255 Blue (0-Black, 255- 100% Blue)

Channel 4 - Internal programs:

11-40 Internal program 1

41-70 Internal program 2

71-100 Internal program 3

101-130 Internal program 4

131-160 Internal program 5

161-190 Internal program 6

191-220 Internal program 7

221-255 Internal program 8

Channel 5 - Strobe:

1~95 Strobe effect slow to fast

128-159 Pulse effect in sequences

192-223 Random strobe effect slow to fast

DESIGN LED 60 Strip™

©Elation Professional, Los Angeles Ca. 23 www.ElationLighting.com

DESIGN LED 60 Strip™

Channel 6 - General dimming / Program Speed Control

This channel has two functions depending on the operating mode. When running the built-in

programs this channel will control the program speed.

0-255 Speed (min to max) ~ When running built-in programs on channel 4

12 Channel Mode: This chart details a simple layout of the DMX channel assignment in

12-channel mode. In this mode all channels are used to control the various RGB LEDs.

DMX channel’s functions and their values (12 Channel Mode):

Channel 1 - Red:

0-255 Red (0-Black, 255-100% Red)

Channel 2 - Green:

0-255 Green (0-Black, 255- 100% Green)

©Elation Professional, Los Angeles Ca. 24 www.ElationLighting.com

Channel 3 - Blue:

221-255 Blue (0-Black, 255- 100% Blue)

Channel 4 - Red:

0-255 Red (0-Black, 255-100% Red)

Channel 5 - Green:

0-255 Green (0-Black, 255- 100% Green)

Channel 6 - Blue:

221-255 Blue (0-Black, 255- 100% Blue)

Channel 7 - Red:

0-255 Red (0-Black, 255-100% Red)

Channel 8 - Green:

0-255 Green (0-Black, 255- 100% Green)

Channel 9 - Blue:

221-255 Blue (0-Black, 255- 100% Blue)

Channel 10 - Red:

0-255 Red (0-Black, 255-100% Red)

Channel 11 - Green:

0-255 Green (0-Black, 255- 100% Green)

Channel 12 - Blue:

221-255 Blue (0-Black, 255- 100% Blue)

©Elation Professional, Los Angeles Ca. 25

DESIGN LED 60 Strip™ www.ElationLighting.com

DESIGN LED 60 Strip™

15 Channel Mode: This chart details a simple layout of the DMX channel assignment in

15-channel mode. In this mode channels 1~12 are used to control the various RGB LEDs and channels 13~15 will control special features.

DMX channel’s functions and their values (15 Channel Mode):

Channel 1 - Red:

0-255 Red (0-Black, 255-100% Red)

Channel 2 - Green:

0-255 Green (0-Black, 255- 100% Green)

Channel 3 - Blue:

221-255 Blue (0-Black, 255- 100% Blue)

Channel 4 - Red:

0-255 Red (0-Black, 255-100% Red)

©Elation Professional, Los Angeles Ca. 26 www.ElationLighting.com

Channel 5 - Green:

0-255 Green (0-Black, 255- 100% Green)

Channel 6 - Blue:

221-255 Blue (0-Black, 255- 100% Blue)

Channel 7 - Red:

0-255 Red (0-Black, 255-100% Red)

Channel 8 - Green:

0-255 Green (0-Black, 255- 100% Green)

Channel 9 - Blue:

221-255 Blue (0-Black, 255- 100% Blue)

Channel 10 - Red:

0-255 Red (0-Black, 255-100% Red)

Channel 11 - Green:

0-255 Green (0-Black, 255- 100% Green)

Channel 12 - Blue:

221-255 Blue (0-Black, 255- 100% Blue)

Channel 13 - Internal programs:

11-40 Internal program 1

41-70 Internal program 2

71-100 Internal program 3

©Elation Professional, Los Angeles Ca. 27

DESIGN LED 60 Strip™ www.ElationLighting.com

DESIGN LED 60 Strip™

101-130 Internal program 4

131-160 Internal program 5

161-190 Internal program 6

191-220 Internal program 7

221-255 Internal program 8

Channel 14 - Strobe:

1~95 Strobe effect slow to fast

128-159 Pulse effect in sequences

192-223 Random strobe effect slow to fast

Channel 15 - General dimming / Program Speed Control

This channel has two functions depending on the operating mode. When running the built-in

programs this channel will control the program speed.

0-255 Speed (min to max) ~ When running built-in programs on channel 4

©Elation Professional, Los Angeles Ca. 28 www.ElationLighting.com

DESIGN LED 60 Strip™

©Elation Professional, Los Angeles Ca. 29 www.ElationLighting.com

DESIGN LED 60 Strip™

10. CLEANING AND MAINTENANCE

The consider the following point during normal service and inspection:

1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall.

2. Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable.

Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.

Disconnect from mains before starting maintenance operation.

We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or solvents.

There are no user serviceable parts inside this, please refer all other service issues to an authorized Elation service technician.

Should you need any spare parts, please order genuine parts from your local dealer.

©Elation Professional, Los Angeles Ca. 30 www.ElationLighting.com

DESIGN LED 60 Strip™

11. 2-YEAR LIMITED WARRANTY

A. Elation Professional

® hereby warrants, to the original purchaser, Elation Professional

® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.

B. For warranty service, send the product only to the Elation Professional

® factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional

® will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional

® shall have no liability what so ever for loss of or damage to any such accessories, nor for the safe return thereof.

C. This warranty is void if the serial number has been altered or removed; if the product is modified in any manner which Elation Professional

® concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the

Elation Professional

® factory unless prior written authorization was issued to purchaser by

Elation Professional

®

; if the product is damaged because not properly maintained as set forth in the instruction manual.

D. This is not a service contract, and this warranty does not include maintenance, cleaning or periodic check-up. During the period specified above, Elation Professional

® will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation

Professional

® under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional

®.

All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that

©Elation Professional, Los Angeles Ca. 31 www.ElationLighting.com

DESIGN LED 60 Strip™ effect.

E. Elation Professional

® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured.

F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional

® in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty period set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said period has expired. The consumer’s and or Dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional® be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product.

G. This warranty is the only written warranty applicable to Elation Professional

®

Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

©Elation Professional, Los Angeles Ca. 32 www.ElationLighting.com

12. PHOTOMETRIC DATA

DESIGN LED 60 Strip™

©Elation Professional, Los Angeles Ca. 33 www.ElationLighting.com

DESIGN LED 60 Strip™

13. TECHNICAL SPECIFICATIONS

AC50Hz~60Hz consumption: 30W

12

Packing dimensions: 47x26.5x19cm (56x48x42cm ~ 4pc system)

Weight: 2.1Kgs / 4.62 Lbs (9.2Kgs ~ 4pc system)

Drive:

Color Mixing:

Beam Angle:

Standard DMX-512, 3 pole XLR; [+] = Pin 3 [-] = Pin 2

[Ground] = Pin 1.

RGB Color Additive Mixing

44˚

Dimmer:

Strobe:

Lamp Life:

Continuous Dimming 0~100%

Electronic Strobe 0~18 Fps

100,000 Hours Rated Life

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

©Elation Professional, Los Angeles Ca. 34 www.ElationLighting.com

DESIGN LED 60 Strip™

Elation Professional

4295 Charter Street

Los Angeles, CA. 90058

323-582-3322 / 323-582-3108 fax

www.ElationLighting.com /[email protected]

©Elation Professional, Los Angeles Ca. 35 www.ElationLighting.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement