Ideal users guide


Add to my manuals
4 Pages

advertisement

Ideal users guide | Manualzz
back
users guide
isar
Your Ideal users guide
HE24,HE30,HE35
For installation guide see reverse of book
When replacing any part on this appliance use only spare parts that you can be
assured conform to the safety and performance specification that we require. Do not
use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers.
back
isar HE24, HE30, HE35
(Natural Gas Only)
Destination Countries: GB, IE
Introduction
The isar is a wall mounted, room sealed, condensing
combination boiler, featuring full sequence automatic spark
ignition and fan assisted combustion.
Due to the high efficiency of the boiler, condensate is produced
from the flue gases and this is drained to a suitable disposal
point through the plastic waste pipe at the lower rear of the
boiler. A condensate 'plume' will also be visible at the flue
terminal.
The isar is a combination boiler providing both central heating
and instantaneous domestic hot water.
Safety
Current Gas Safety (Installation & Use)
Regulations or rules in force.
In your own interest, and that of safety, it is the law that this boiler
must be installed by a CORGI registered installer, in accordance
with the above regulations.
In IE, the installtion must be carried out by a Competent Person
and installed in accordance with the current edition of I.S. 813
“Domestic Gas Installations”, the current Building Regulations
and reference should be made to the current ETCI rules for
electrical installation.
It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.
HE24
HE30
HE35
G.C. Appliance No. 47-348-31
G.C. Appliance No. 47-348-30
G.C. Appliance No. 47-348-29
In cases of repeated or continuous shutdown a CORGI
registered installer or in IE a competent person should be called
to investigate and rectify the condition causing this and carry out
an operational test. Only the manufacturers original parts should
be used for replacement.
Minimum Clearances
Clearances of 165mm (6 1/2") above, 100mm (4") below, 5mm
(1/4") at the sides and 450mm (17 3/4") at the front of the boiler
casing must be allowed for servicing.
The minimum front and bottom clearance allowed when built
into a cupboard is 5mm.
To light the boiler. Refer to Frame 1
If a programmer is fitted refer to separate instructions for the
programmer before continuing.
1. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER
IS OFF.
2. Set the mains ON/OFF switch (A) to OFF and the DHW
thermostat knob (J) and CH thermostat knob (F) to
maximum.
3. Ensure that all DHW taps are turned off.
4. Switch ON the electricity supply to the boiler and check that
all external controls, e.g. programmer, room thermostat etc.,
are ON.
5. Set the mains ON/OFF switch to ON.
Electricity Supply
This appliance must be earthed.
Supply: 230 V ~ 50 Hz. The fusing should be 3A.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double-pole switch,
having a 3mm (1/8") contact separation in both poles, serving
only the boiler and system controls. Alternatively, a 3-pin
UNSWITCHED socket may be used. The means of isolation
must be accessible to the user after installation.
Important Notes
z This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.
z If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
z If it is known or suspected that a fault exists on the boiler
then it MUST NOT BE USED until the fault has been
corrected by a CORGI registered installer or in IE a
competent person.
z Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.
z This appliance is not intended for use by persons (including
chilcren) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instructions concerning
use of the appliance by a person responsible for their safety.
The boiler will commence the ignition sequence, first supplying
heat to preheat the domestic hot water and then to the central
heating, if required.
Note. In normal operation the control unit display (C) will show
codes:
0
Standby - no demand for heat.
CH being supplied.
DHW being supplied.
DHW preheat.
During ignition, the LED (E) will flash.
During normal running the LED (E) will remain illuminated.
Note. If the boiler fails to light after 3 attempts the fault code
will be displayed.
Press the reset button (D) for 2 seconds then release. The
boiler will repeat the ignition sequence. If the boiler still fails to
light consult a CORGI registered installer or in IE a competent
person.
Operation
Winter conditions - i.e. CH and DHW required.
The boiler will fire and supply heat to the radiators but will give
priority to DHW on demand.
The DHW preheat will operate as described under 'Summer
conditions' during periods when there is no call for CH.
z Children should be supervised to ensure that they do not
play with the appliance.
All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded
in the Benchmark Commissioning Checklist. You can check your installer by calling CORGI direct on 01256 372300.
Ideal Stelrad Group is a member of the Benchmark initiative and fully supports the aims of
the programme. Benchmark has been introduced to improve the standards of installation and
commissioning of central heating systems in the UK and to encourage the regular servicing of
all central heating systems to ensure safety and efficiency.
THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE
2
isar - User’s
back
Summer conditions - i.e. DHW only required.
Set the CH external controls to OFF, or turn the CH thermostat
knob (F) to minimum.
The boiler will fire periodically for a few seconds to maintain the
DHW calorifier in a preheated condition. The average time
period between firing is 90 minutes. This may vary considerably
due to the surrounding ambient temperature of the boiler. The
boiler will fire whenever there is a demand for DHW.
Note. The pump will operate briefly as a self-check once every
24 hours, regardless of system demand.
Control of water temperature
Domestic Hot Water
The DHW temperature is limited by the boiler controls to 65oC
maximum at low draw-off rate, adjustable via the DHW
thermostat knob (J).
Due to system variations and seasonal temperature fluctuations
DHW flow rates/temperature rise will vary, requiring adjustment
at the draw off tap : the lower the rate the higher the temperature,
and vice versa.
Central Heating
The boiler controls the central heating radiator temperature to a
maximum of 82oC, adjustable via the CH thermostat knob (F).
Approx. flow temperatures for the boiler thermostat settings are:
Knob Setting
Flow Temperature
o
o
C
F
Minimum
30
86
Maximum
82
180
To shut down the boiler
1. For short periods
Set the mains ON/OFF switch (A) to OFF
2. For longer periods
Set the mains ON/OFF switch (A) to OFF, and switch the
electricity supply to OFF. For longer periods the entire system
should be drained.
fitted) ONLY. The mains supply should be left switched ON, with
the boiler thermostat left in the normal running position.
Boiler overheat thermostat
This thermostat will shut down the boiler in the event of
overheating. Should this occur a fault code
will be displayed.
Press the reset button (D) and the boiler will relight.
If the fault recurs, turn off the boiler and consult a CORGI
registered installer or in IE a competent person.
Flame failure
Should this occur a fault code
will be displayed.
Press the rest button (D) and the boiler will relight.
If the fault recurs, turns off the boiler and consult a CORGI
registered installer or in IE a competent person.
Loss of system water pressure
The gauge (H) indicates the central heating system pressure. If
the pressure is seen to fall below the original installation
pressure of 1-2 bar over a period of time then a water leak may
be indicated. In this event conduct the re-pressurising procedure
(see Trouble Shooting - Problem 4). If unable to do so or if the
pressure continues to drop a CORGI registered installer or in IE
a competent person should be consulted.
DO NOT FIRE THE BOILER IF THE PRESSURE HAS
REDUCED TO ZERO FROM THE ORIGINAL SETTING.
Condensate Drain
The condensate drain (G) must not be modified or blocked.
Blockage of the condensate drain, caused by debris or freezing,
can cause automatic shutdown of the boiler.
If freezing is suspected and the pipe run is accessible an
attempt may be made to free the obstruction by pouring hot
water over the exposed pipe and clearing any blockage from the
end of the pipe. If this fails to remedy the problem the
assistance of a CORGI registered installer or in IE a competent
person should be sought.
Escape of gas
Should a gas leak or fault be suspected contact your local gas
supplier without delay.
Do NOT search for gas leaks with a naked flame.
To relight the boiler
Repeat the procedure detailed in 'To light the boiler'.
Cleaning
For normal cleaning simply dust with a dry cloth.
Frost protection
If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls (if fitted) at a
reduced temperature setting. For longer periods, the entire
system should be drained.
If the system includes a frost thermostat then, during cold
weather, the boiler should be turned OFF at the time switch (if
1
To remove stubborn marks and stains, wipe with a damp cloth
and finish off with a dry cloth.
DO NOT use abrasive cleaning materials.
Maintenance
The appliance should be serviced at least once a year by a
CORGI registered installer or in IE a competent person.
BOILER CONTROLS
Legend
A.
C.
D.
E.
Boiler ON/OFF switch.
Display.
Reset button.
LED.
F.
G.
H.
J.
CH thermostat knob.
Condensate drain.
Pressure gauge.
DHW thermostat knob.
CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning
of this appliance care should be taken when handling edges of sheet steel components.
isar - User’s
3
back
POINTS FOR THE BOILER USER
Note. In line with our current warranty policy we would ask that you check through the following guide to identify any
problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than
with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained
by the engineer.
TROUBLESHOOTING - TYPICAL NON PRODUCT FAULTS
Problem
1 Boiler is not working for
central heating or hot water.
Solution
•
Check there is power to the boiler – switch (A) in the ON position and ‘0 ’ displayed on the
controls.
•
If ‘0 ’ not displayed then not a boiler fault – contact your installer/service company.
2 Boiler is not working for
•
central heating or hot water
•
but attempts to fire by going
through 3 ignition attempts.
Display shows ‘L : F ’ (flashing). •
Press reset button (D) for 2 seconds to repeat ignition sequence.
3 Boiler is not working for
central heating or hot water
and the display shows ‘L:A ’
(flashing).
•
Press reset button (D) for 2 seconds, the boiler should then re-light. If fault recurs this
indicates an overheat condition. The boiler should be turned off and your installer contacted.
•
Check if ALL radiators have thermostatic radiator valves fitted. If they have contact your
installer.
4 Boiler is not working for
central heating or hot water
and the display shows ‘H:A ’
(flashing).
•
Check pressure gauge on boiler shows a minimum of 1 bar. If not re-pressurise via the filling
loop to 1 bar (if unsure contact your installer), turn off the tap on the filling loop and turn the on/
off switch (A) off and then back on again to reset the boiler. If unable to do so or if the pressure
continues to drop after filling then contact your installer.
•
Check if ALL radiators have thermostatic radiator valves fitted. If they have contact your
installer.
•
Check external programmer is set to an ‘ON’ period.
•
If already set to an ‘ON’ period then check the programmer by setting to continuous if boiler
then fires – Contact your installer to rectify the programmer.
•
Check room thermostat by turning fully up, If ‘0’ is not displayed on the user controls then
contact your installer.
6 Boiler comes on for
domestic hot water without a
tap being opened - the
display shows ‘D’.
•
Check for dripping / dribbling taps or showers – turn fully off.
•
Check for leaks from the domestic hot water pipework and if found contact your installer.
7 Boiler fires occasionally for
approx. 2 minutes - the
display shows ‘t’.
•
This is a normal function of the boiler to periodically pre heat the plate heat exchanger to
optimise delivery time for domestic hot water to taps or showers.
5 Boiler will not fire for central
heating.
Check gas supply (try another appliance – cooker/fire etc.) – If no gas supply then not a boiler
fault – contact gas supplier.
Check condensate pipe is not blocked or frozen. If blocked clear blockage – if not possible to
check contact your installer.
The nature of all combination boilers is to heat up water directly from the incoming mains water supply directly through the boiler
to supply domestic hot water at the stated flow rates, (as shown in the boiler installation instructions), to achieve a 35oC
temperature rise. As the ambient temperature of the cold main varies during the summer and winter months it is likely in the
colder winter months that the flow rate will need to be reduced at the outlet taps to achieve the same temperatures achieved in the
warmer summer months. This is not a fault with the appliance but is relevant to the varying temperature of the incoming cold
mains water supply.
Ideal Consumer Helpline
Tel: 01482 498660
www.idealboilers.com
Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance
of its products. The right is therefore reserved to vary specification without notice.
Ideal Boilers, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel.
01482 492251 Fax. 01482 448858. Registration No. London 322 137.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement