Ideal icos HE30 User manual


Add to my manuals
4 Pages

advertisement

Ideal icos HE30 User manual | Manualzz

back

users guide

icos

Your Ideal users guide

See reverse for icos installation & servicing instructions

HE30, HE36

When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers.

202414-6.pmd

57 19/02/2008, 13:08

back icos HE30, HE36

(Natural Gas Only)

Destination Countries: GB, IE

HE30

HE36

G.C. Appliance No. 41-399-10

G.C. Appliance No. 41-399-16

Introduction

The icos is a wall mounted, room sealed, super efficient condensing boiler featuring full sequence automatic spark ignition and fan assisted combustion.

Due to the very high efficiency, condensate is produced from the flue gases and this is drained to a suitable disposal point through the plastic waste pipe at the right lower rear of the boiler. A condensate 'plume' will also often be visible at the flue terminal.

S a f e t y

Current Gas Safety (Installation & Use)

Regulations or rules in force.

In your own interest, and that of safety, it is the law that this boiler must be installed by a CORGI registered installer.

In IE the installation must be carried out by a competent person and installed in accordance with the current edition of

I.S. 813 “domestic Gas Installations”, the current Building

Regulations and reference should be made to the current

ETCI rules for electrical installation.

It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler.

• This appliance is not intended for use by persons

(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

• Children should be supervised to ensure that they do not play with the appliance.

In cases of repeated or continuous shutdown a CORGI registered installer or in IE a competent person should be called to investigate and rectify the condition causing this and carry out an operational test after each intervention on the device. Only the manufacturers original parts should be used for replacement.

Minimum Clearances

Clearances of 165mm (6 1/2") above, 150mm (6") below,

15mm (5/8") at the sides and 450mm (17 3/4") at the front of the boiler casing must be allowed for servicing.

The minimum front and bottom clearance allowed when built into a cupboard is 5mm.

Electricity Supply

The appliance must be earthed.

Supply 230 V - 50 Hz. The fusing should be 3A.

This appliance is intended to be connected to the supply via a double-pole switch, having a 3mm contact separation in both poles, serving only the boiler and system controls. Alternatively, a 3-pin UNSWITCHED socket may be used.

To light the boiler

(Refer to Frame 1)

1. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER

IS OFF.

2. Set the mains on/off switch (A) to off and the CH thermostat knob (C) to maximum.

3. Switch on the electricity supply to the boiler and check that all external controls, e.g. programmer, room thermostat, etc are on.

4. Set the mains on/off switch to ON.

The boiler will commence the ignition sequence, supplying heat to the system when required.

Important Notes

• This appliance must not be operated without the casing correctly fitted and forming an adequate seal.

• If the boiler is installed in a compartment then the compartment

MUST NOT be used for storage purposes.

• If the boiler is installed with a loft air grille and roof flue, the loft must not be used as a living space and care must be taken to ensure that the loft air grille is not blocked.

• If the appliance is fitted with a twin flue system using a loft air grille and both the boiler and grille are installed within a cupboard or compartment, then permanent air vents are required and care must be taken to ensure that the air vents are not blocked.

• Under NO circumstances should any of the sealed components on this appliance be used incorrectly or tampered with.

• If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a CORGI registered installer or in IE a competent person.

Operation

In normal operation the control unit display (F) will show the codes:

O - Standby (no demand for heat)

C - CH or DHW being supplied

P - Boiler frost protection (boiler will fire when temperature is less than 3 o C)

During ignition the LED (E) will flash.

During normal running the LED will remain illuminated.

Note. If the boiler fails to light after 3 attempts the fault code 'L' 'F' will be displayed.

Press and hold the reset button for 2 seconds then release.

The boiler will repeat the ignition sequence. If the boiler fails to light consult a CORGI registered installer or in IE a competent person.

2

All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded in the Benchmark Commissioning Checklist. You can check your installer by calling CORGI direct on 01256 372300.

Ideal Stelrad Group is a member of the Benchmark initiative and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.

THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE

icos -

Users

202414-6.pmd

58 19/02/2008, 13:08

back

Control of water temperature

The boiler controls the central heating radiator temperature to a maximum of 82 0 C, adjustable via the CH thermostat knob (C).

Approx CH flow temperatures for the boiler thermostat settings are:

Knob Setting Flow Temperature o

C o

F

Minimum

Maximum

30

82

86

180

To shut down the boiler

1. For short periods

Set the mains on/off switch (A) to OFF.

2. For longer periods

Set the mains on/off switch (A) to OFF. Switch the electricity supply to OFF. For longer periods the entire system should be drained, including the domestic hot water supply.

To relight the boiler

Repeat the procedure detailed in 'To light the boiler'.

Boiler Overheat Thermostat

This thermostat will shut down the boiler in the event of overheating. Should this occur a fault code 'L' 'A' will be displayed. Press the reset button (D) and the boiler will relight.

If the fault recurs turn off the boiler and consult a CORGI registered installer or in IE a competent person.

Flame failure

Should this occur a fault code L-F will be displayed. Press the reset button and the boiler will relight. If the fault recurs, turn off the boiler and consult a CORGI registered installer or in IE a competent person.

Condensate Drain

The condensate drain must not be modified or blocked.

Blockage of the condensate drain, caused by debris or freezing, can cause automatic shutdown of the boiler.

If freezing is suspected and the pipe run is accessible an attempt may be made to free the obstruction by pouring hot water over the exposed pipe and clearing any blockage from the end of the pipe.

If this fails to remedy the problem the assistance of a CORGI registered installer or in IE a competent person should be sought.

Escape of gas

Should a gas leak or fault be suspected contact your local gas supplier without delay.

Do NOT search for gas leaks with a naked flame.

Frost Protection

If no frost protection is provided and frost is likely during a short absence from home leave the heating controls (if fitted) at a reduced temperature setting.

For longer periods the entire system should be drained.

If the system includes a frost thermostat then, during cold weather, the boiler should be turned OFF at the time switch (if fitted) ONLY. The mains supply should be left switched ON, with the boiler thermostat left in the normal running position.

Cleaning

For normal cleaning simply dust with a dry cloth.

To remove stubborn marks and stains use a damp cloth and mild detergent.

DO NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a CORGI registered installer or in IE a competent person.

1 BOILER CONTROLS

D

E

F

B

C

Legend

A Boiler on/off switch

Thermostat knob

Reset button

LED

Display

Condensate drain

E C D

F A B

CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning of this appliance care should be taken when handling edges of sheet steel components.

icos -

Users

3

202414-6.pmd

59 19/02/2008, 13:08

back

POINTS FOR THE BOILER USER

Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer.

TROUBLESHOOTING - TYPICAL NON PRODUCT FAULTS

Problem

Boiler is not working for central heating or hot water.

Boiler is not working for central heating or hot water but attempts to fire by going through 3 ignition attempts.

Boiler is not working for central heating or hot water and the display shows ‘L:A

(flashing).

Boiler is not working for central heating or hot water and the display shows ‘H:A

(flashing).

Solution

• Check there is power to the boiler – switch (A) in the ON position and ‘0 ’ displayed on the controls.

• If ‘0 ’ not displayed then not a boiler fault – contact your installer/service company.

• Check external programmer is set to an ‘ON’ period and the relevant function selected i.e.

central heating or domestic hot water. Test by overriding the programmer by setting to

‘continuous.

• Check room thermostat for central heating or the cylinder thermostat for domestic hot water, are set at the required temperature. To test operation of either thermostat turn fully up. If no response contact your installer.

• Press reset button (D) for 2 seconds to repeat ignition sequence.

• Check gas supply (try another appliance – cooker/fire etc.) – If no gas supply then not a boiler fault – contact gas supplier.

• Check condensate pipe is not blocked or frozen. If blocked, clear blockage – if not possible to check contact your installer.

• Press reset button (D) for 2 seconds, the boiler should then re-light. If fault recurs this indicates an overheat condition. The boiler should be turned off and your installer contacted.

• Check if ALL radiators have thermostatic radiator valves fitted. If they have contact your installer.

• Check if ALL radiators have thermostatic radiator valves fitted. If they have contact your installer.

202414-6.pmd

Ideal Consumer Helpline

Tel: 01482 498660 www.idealboilers.com

Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice.

Ideal Boilers, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel.

01482 492251 Fax. 01482 448858. Registration No. London 322 137.

60 19/02/2008, 13:08