Instruction Manual


Add to my manuals
13 Pages

advertisement

Instruction Manual | Manualzz
=
a | = =
y, Thank you for patronizing our products.
ARCTICA
COMMERCIAL SERIES TITANIUM CHILLER
Installation, Operating and Maintenance Manual
y
>| DA- 500 Series ZA
DA - 700 Series &
DA - 1000 Series Ma
DA - 1500 Series *
DA - 2000 Series I
DA - 3000 Series - 2 He
=k,
\
a E, —
| ® ===
|
www.jbjlighting.com
Distributed by : TRANSWORLD AQUATIC ENTERPRISES, INC.
TEL:(310) 672-0480 FAX:(310) 672-7261
DE Contents Homepage : www. Tre com
+ Thank you for patr oniz zing our products. D
* Please read this operating manual before using the cooler.
ARCTICA- — It will enable you to use it more safely and ensure it's long life.
JBJ Cooler Features
— Proud of high cooling performance
—| Designed exclusively for salt water tank
— Uses a special titanium heat-exchanger
not detrimental to live fish
—t Designed for convenient use
—t- Corrosion-resistant
—+ Accurate control of water temperature
with remote—control operation of the temperature
controller
—+— Protects from heat-exchanger crack by freezing
with internal sensor
—+— Convenient installation
«> =
\
Ready to Use
Safety Precautions ......... Pp ~ BP
Part Names EB 8 EE 8 BW 6P
Installation of Thermostat Controller ......... GP
How to Use
Checkup before use escocesa TP
Optimal temperature/humidity for cooler operation
Cooler Operation
Thermostat controller operating method .......... Par
Power on/off
Adjusting the preset temperature
Auto Operation
Indication of Abnormality
Indication Lamp
Installation Before Use
Cooler Installation .0......« OP ~ 10Р
Cooling Water Pipes Installation
Cooler Setting
Fixing thermostat sensor
Installing pipes
Connecting ground circuits
Thickness of power line and capabilities of circuit breaker
Connecting to the power source
Installing thermostat sensor
Ground Installation
Checkup Before Requesting Service vease JOP ~ {IP
Please be sure to confirm the following instructions before requesting service,
Saving Energy ....... 12P
When installing
When Using
Others
Specifications
1 |1
TEED > Safely Precautions — спинлНиНиНиНиЫ
* User safety and protection of property
Please read all instructions for proper use.
É This manual describes the operation, installation and operating cautions of the cooler,
« Read this manual and have it handy so as to refer to it whenever you have a question.
* Do not operate beyond the instructions of the manual. It may cause a problem,
and in such an event the user may take responsibility for the problem,
* For the best performance of the cooler please ensure you fully comprehend
the instructions of the manual before using the cooler.
( Indication
„К
Prohibition
Failing to follow the instructions
may cause death or severe injury.
A CAUTION
Failing to follow the instructions
| may cause injury or property damage.
Disassembly prohibited
Be sure to follow this.
Remove plug from outlet,
Оо
Ground to prevent electrocution,
J
Read "Safety Precautions” before use,
The instructions about danger, warning and caution described here are for the right use of the cooler
and protecting human lives and property. Please be sure to follow the instructions.
N
A
Do not set the cooler on the aquarium or in a damp place.
«lt may cause fire, electric leakage or other problems.
Do not put fingers or other items in the cooler jet.
ein particular, take care to ensure that children do not put their fingers in it.
Do not pull out the line or touch the outlet with wet hands.
«lt may cause electric shock or fire.
Do not disassemble or move the cooler while driving.
eilt may cause electric shock or other problems.
Do not connect an electric heater to the cooler or take it apart, -
repair or modify it without specific instructions.
® |! may cause trouble, electric shock or fire.
Contact the service center when a repair is needed,
Before cleaning the aquarium or renewing water, make sure
you shut off the no—fuse breaker and circuit breaker for safety.
sit may cause electric leakage, electric shock or other problems.
Do not connect the ground wire to a gas pipe,
water pipe or telephone wire.
elt may cause electric shock.
Be sure to ground when installing the cooler.
* Otherwise, there is a danger of electric shock,
Use a single power source with
an exclusive wiring system for the cooler,
* Otherwise, there is a danger of electric shock or fire.
uN ||
© E 6 SY 2 O02 VU
Ready to Use > Safety Precautions
Be sure to ventilate the cooler
when installing it in the aquarium.
e [f poor ventilation does not allow warm air to escape,
it may cause fire or trouble, including lowering the cooling performance,
Install a thermostat on the floor of the aquarium
when installing the cooler in the aquarium,
e |f water falls down on the floor of aquarium, it may cause fire,
electric leakage or other problems,
Install a no-fuse breaker and circuit breaker for the cooler.
* Otherwise, there is a danger of electric shock or fire.
ein the case a circuit breaker is in common use,
if the power source is cul off because of the cooler,
the stoppage of devices for the cooler may Kill the fish,
Circuit breaker
«it may cause fire, electric shock or loss of human lives or property,
Do not connect to the power source together with other devices. ı 3
Do not put the cooler in a place with near
of inflammable gas leak, direct sunlight or hot air.
e Gas leakage around the cooler may cause explosion or fire,
Do not put the thermostat controller in a damp place,
on or around the aquarium.
¢ [t may show an abnormal sense of temperature or cause problems,
Do not bend the electric wire by force
or do not put heavy items on it.
«it may cause electric shock or fire.
oy
Do not use a damaged power cord or plug, or loose outlet. op
e |! may cause electric shock or fire.
a
Do not use a cracked cord. a
«it may cause electric shock, electric leakage or fire. mme
Do not install the cooler in an unstable place.
e |f the cooler falls down, a loss of human lives or property may arise,
Do not spray insecticide or inflammable materials on the cooler.—
LS
a
Г
EN o i
ES
r 2
s Not only It is detrimental to your health,
but also it may cause fire or other problems.
In case the water temperature sensor is an external type,
make sure you put it in the water of the aquarium.
sa Otherwise, malfunction or other problems may arise.
Do not use the cooler in an area
where input voltage is lower than 200V?
«The cooler may not work and problems may arise.
QO © © VV | © до о
Be careful that you do not get the cooler,
thermostat controller connecting cords, or sensor cords wet.
«it may cause electric leakage, fire or trouble.
=)
iis Ali
3
Ready to Use gp Safety Precautions
A WARNING
® In case of using plural coolers, be careful
not to connect the thermostat to the wrong cooler.
* The cooler may not work.
Do not place one cooler upon another cooler,
* № may cause noise, electric shock, fire or other problems.
Check the operation of the circulating pump from time to time, =
Do not operate the cooler without water flow or X
when the circulating pump is out of order, a
® |! may lower the cooling performance and cause problems.
Use seamless cord when connecting to the power source. o)
e Otherwise, it may cause a short circuit or a broken wire, а
which may result in fire, electric leakage or other problems.
Only use a fuse with a properly rated capacity.
¢ Especially, do not use wire or copper wire in place of the fuse,
There is a risk of other problems including fire,
Shut off the breaker when connecting temperature sensor line,
ensure wire colors correspond, and attach
the water-proof tape to prevent water infiltration.
* Otherwise, it may show an abnormal sense of temperature or S$
cause other problems.
In the case a strange noise, burning smell or smoke arises,
immediately turn off the cooler, shut off the power source,
and then refer to the service center. ==
* There is a danger of electric shock or fire, Sa
ето
For installing the cooler, make sure you refer to
an exclusive JBJ cooler distributor or
an exclusive JBJ cooler agent for installation.
There is a danger oi water leakage, electric shock, fire or other problems.
*In particular, you must refer to the distributor at which you purchased the cooler or
a service center when installing it at a factory area or
any other special places such as a salty seaside area.
Make sure you ventilate the cooler from the front and rear.
Leave a space of 8inch in the rear, and 4ft in both sides, )
and do not put other items within 5ft of the front side. >
«it may lower the cooling performance and cause problems.
Do not install the cooler in a place
where there is a fear of submergence. dito
elt may cause electric shock, electric leakage, fire or any other problems. =
*
ab Be careful that you do not get the cooler wet when cleaning it
or renewing the water.
“А
* Make sure you unplug the cooler when cleaning it.
a
Td
—
4 CAUTION
CS Do not forget to use JBJ products for и
the thermostat controller. We take no responsibility EZ
for problems due to the use of other products.
® Do not use the thermostat controller for other purposes
than controlling the water temperature within the aquarium. (jos ) E
* Do not use it for precision devices, food, animals or plants.
It may lower the cooling performance or cause problems.
|||
ES > Safety Precautions — aa
A CAUTION
© 9 9 OO 9 9 99 © © ОО
Avoid water penetrating into the cooler.
alt may cause electric shock or fire,
Do not spray water on the cooler directly or
clean it with benzene, alcohol or other thinners.
e |t may cause electric shock or fire.
Do not install the cooler without grommet.
s Problems including noise due to vi bration may arise.
Be careful that men, animals or plants are not
directly exposed to the air from the cooler.
e|t Is detrimental to human body,
and may have a bad impact on animals or plants.
Do not turn off the cooler by an auxiliary switch,
«it may cause problems including electric shock.
Make sure you turn off the cooler by pressing the "POWER" button.
Do not climb up to the cooler or do not put heavy items on it.
e |t may cause problems including electric shock,
and the falling of such an item may cause injury,
To clean or repair the cooler, first shut off the power source
and wait until the fan stops rotating.
* Otherwise, it may cause electric shock or injury.
Contact the distributor at which you purchased the cooler or
a service center, when a repair is needed.
« Disassembly or repair without specific instructions
may cause electric shock or fire.
Be careful of the heat exchanger in the cooler
when cleaning it since its surface is sharp.
e Put on thick cotton gloves to protect from finger cuts.
or hot air, or in a damp place.
Do not install the cooler in a place with fear of direct sunlight#2f À
eit may lower the cooling performance and cause problems, и
Do not install the cooler on sloping ground,
«lt may cause vibration, noise or other problems.
Clean the condenser every month.
e Neglecting to clean it may lower the cooling performance
and cause problems.
Do not move the cooler on it's side,
drop it or impact it against anything.
«lit may cause problems including safety problem.
In linking water pipes, use standard piping materials,
and avoid water penetration into the cooler 0
when fitting the connector.
In installing the cooler, choose a place without obstacles
and with good ventilation, and where the noise arising
out of operating the cooler has little impact
on the neighborhood.
es Otherwise, problems may arise,
and the noise may give inconvenience the neighbors .
5 1
Ready to Use 3 Part Names
“ A CAUTION
Do not install the cooler by suspending it on an external wall, outside veranda or
any other unstable place.
If the cooler falls down, a loss of human lives or property may arise.
DA- 500B,L. DA-1000B,L
DA-2000B,L,C,CL
DA-1500B,L
Internal Type DA- SOON, DA=1000N Sas
DA-3000B,L,C,CL
[Thermostat Controller
| Thermostat Controller = | Thermostat Controller
rá Sensor Line| $ ЗЕД Sensor Line] Ep Sensor Line]
¡Power Plug for Main Unit
[Power Plug for Main Unit] [Power Plug for Main Unit
[ Only for Circuit Breaker | : A
Г
| у
|
Main Unit
Thermostat Controller Installation Thermostat Controller
[Digital Temperature Indicator| [Indication Lamp | | Adjustment Button |
MS Éd
Fa
>
ELECTACA TRACE = SOIT, PAIN
ARCTICA”
Automatic Conprader [0)-823F
Correct fit will be indicated by a “tick” sound,
Insert the thermostat downward by pressing it. | |
\
\ ce
Fasten the back board to the wall with screws. | [Cooler Power Cord]
sensor Wire
Controller Power Cord |
How To Use Cooler | Cooler Operation
Optimal temperature/moisture for cooler operation
If you operate the cooler in excess of the optimal range of temperature and humidity,
it may stop to operate due to the detection by the protection device.
In particular, do not operate the cooler when the outdoor temperature is below 50°F.
It may cause problems.
* Controlled temperature and ambient temperature around the cooler: 70°F — 104°F
+ Controlled temperature and ambient humidity around the cooler: Relative Humidity below 80%
(High moisture may cause electric shock or fire due to poor insulation.)
111}
TENERTE > Cooler Operation — aa
Checkup before use
Be sure to check the following items before using the cooler:
1. Check if there is any obstacles around the cooler.
» Clear it away if any, It may lower the cooling efficiency due to poor ventilation, and cause problems.
2. Check if the no-fuse breaker or circuit breaker is switched on or not.
* |f the no—fuse breaker or circuit breaker is switched off,
the cooler will not work by simply pressing the "START/STOP" button.
= Our product does not include no-fuse breaker and circuit breaker. You need to purchase them separately.
>) They are devices to prevent electric leakage due to overcurrent, Separately install them around the cooler
or thermostat controller, and shut them off when cleaning the cooler or not operating it for a long-term,
3. Check the circulating pump and piping for water leakage and cooling water flow.
* A weak flow of cooling water may lower the cooling performance.
* Be careful not to switch or incorrectly fit the cooling water inlet (coming out of circulating motor)
and the outlet(going out to aquarium).
4. Check the temperature sensor.
+ In case the sensor is an external type, make sure you put it in the water of the aquarium.
Be careful that the sensor does not come out of the water when taking out fish or cleaning the aquarium,
Cooler Operating Methods
1. Switch on the earth leakage circuit breaker and no—-fuse breaker.
2, Press the thermostat "POWER" button. (operation of thermostat)
3. Check the desired water temperature of the aquarium by pressing the "UP" button.
4. If you want to change the preset temperature,
adjust it according to the instructions on page 8,
5. If the water temperature of the aquarium is higher than the preset temperature,
the indication lamp will illuminate after flashing for 3 minutes.
Then the cooler will start to work, Afterward, the cooler will automatically control
the water temperature of the aquarium within =1F of the preset temperature.
. Press the "POWER" button one time to turn the cooler off.
, Switch off the earth leakage circuit breaker and no-fuse breaker
when not using the cooler for a long-term.
~ ©)
Thermostat Controller Operating Method
» Use our thermostat controller as it is purposefully made for this use.
* A large-capacity power relay (15A/250V) is embedded.
* There is an error of £1°F by IC temperature sensor.
* Since the water temperature at the time of product release is preset with 57°F, you may instantly use
the thermostat controller without adjusting it if you want around 57°F water temperature.
Power OvOff
CO) Press the "POWER" button one time.
* When the present water temperature is displayed on the Display Window,
the thermostat auto control operation will start.
O) Press the "POWER" button once again.
* The Display Window will be deactivated and the thermostat will be
in "wait" status.
POWER
POWER
A FMALITIAR
Á CAUTION
In this status, the thermostat is not completely "turned-olf",
but just is in a suspended state, In case the operation is suspended for a long time,
or the power source is shut off, switch off the safety circuit breaker,
i Ш
j
TENERTE > Cooler Operation — aa
Thermostat Controller Operating Method
Auto Operation = >
The thermostat maintains and controls the preset temperature,
automatically oscillating "on" and "off" to maintain the preset temperature.
» Deviation of Turn—on and Turn—off
« The thermostat will "turn—on" 1°F higher than the preset temperature,
« The thermostat will "turn-off" 1°F lower than the preset temperature,
You have to wait for three (3) minutes at the "turned-on" temperature,
It will normally start to work after three (3) minutes.
" The three-minutes' waiting time is to protect the compressor motor, 60°F TERE Cycle
which is an important part of the cooler, against the pressure change —
of refrigerants from the cooler, However, the deviation of "turn-on" and Set Temperature 59F [= == jo — a
“turn—off" and the wailing time are not changed. 58°F
Turned-off
Adjusting the Preset Temperature \
» Example
To change temperature from 59°F to 64°F.
UP | w LN YF» BL LER a
ZZ. | > > a a a |
Ea > o || y > - A ЕЩЕ má == IE (@) > MA 1,1
PTAS E
Keep pressing the up | The decimal point Adjust the value by The value renewed will be
button for about 3 blinks. Depress when | pressing button sequentially. | memorized into unit after
seconds. The displayed | the number blinks. 10 seconds.
value changed.
ha, A
P Indication of Abnormality -
Turned-off The cooler is not in operation.
. The cooler is preparing for operation.
Flashin
с © COOL 9 (It will flash for three minutes.)
Turned-on The cooler is in operation,
P Indication Lamp
When the displayed temperature
Er { Abnormal signal is over 122°F. When there is — Check if the wire got damp or
of sensor a broken wire or problem on wiring. there is a problem on wiring.
: — Check if the sensor wire is broken
_ I Abnormal signal When there is a broken wire or or bent intensely,
I". | of sensor problem on wiring,
When there is a problem — Unplug the power cord, and then
E = Abnormal signal of on power compensation. plug it again after ten seconds.
I internal thermostat When there is a problem on setting
and operating memory.
Installation Before Use
Cooling Water Pipes Installation
A CAUTION
awilching the waler cooling inlel and the oullel may change
the cooling performance and cause malfunclion,
Cireulatinog Pump
Cooler Installation
Cooler Setting
A CAUTION
In Installing the Internal cooler type, be sure to use
ventilating windows{louver) for air vents on the Iron! side
and backside. Foor ventilation may cause problems.
Fa E
— 1 Air vent e =— Air vent
… Aquarium Machine room ______..
A CAUTION
Leave a space of 8 in the rear, and some space in both sides
Do not put other Items within Sft from the front side,
Filtering Tank fl
Г]
Circulating Pump
Circulating Pump
Remove
other tema = ä
{ i
within rom CIN A x
the front side,
Eas Hat E Hot в
asi Coole / ol air lu
Hot air a — 1 N ==
(O) Ea
(X)
Connecting to the power source and installing thermostat sensor
x
A CAUTION External Sensor Type
# With this sensor type, abnormal motor function or
A 07:10] E Internal Sensor Type
* The sensor Is buill-in to the cooler.
water circulation can cause the chiller breakage.
" Fix the sensor not so as to come out ol the water when taking out fish
or cleaning the aquarium,
Marmortar controlar
Circuimting Pump
Installing pipes
Switching the walter cooling inlet and
the outlet may lower lemperaturg sensing.
lhermostal controller
buill=in sensor
i ï
Cooler
I
i
+
Filtering Tank
Circuinting Pump
* In linking water pipes, Joint
use standard piping materials,
and avoid water penetration
into the cooler when fitting
the connector.
O Water-proof Rubber
Cap |
PVC Pipe y
»
PVC Pipe
Water-proo! Rubber
Ground Installation
A CAUTION Be sure to ground to prevent electric shock. E
e Strip the covered wire and drive In the copper pipe around the aquarium,
and then ground It. If there ls any ironware around the bottom of the aquarium,
ground to it. However, don't ground to a tap.
Cooler
Cooler
ground wira
Filtering tank [PAR
Circulating pump
Ground terminal
FIT
TT r
Thickness of power line and capabilities of circuit breaker
A CAUTION Follow the instructions below to prevent fire and secure safety.
es Lise thicker wires as the distance between the cooler and the main breaker ls farther.
s Use seamless cord when connecting it to the power source,
Capabilities of
Capabilities of
Wire size (AWG) p Wire size (AWG) | Capabilities of | Capabilities ol
MODEL Up te SON | Over s0f Circuit Breaker [No uno Esmalte MODEL Un to son |. over Sof Creu oras Nozflse rana
DA - 700 Series| 14 12 I <0 DA -1000N 14 12 10 20
DA -1000 Series 14 12 10 20 es
DA -2000 3PH 208-230V 14 12 10 20
DA -1500 Series! 14 12 15 25 460V 16 14 6 20
= i 14 12 2 2 =
DA -2000 Series 0 3 DA -3000 3PH 208-230V 14 12 15 25
DA -3000 Series 12 10 30 50 460V 14 12 10 20
Installation Before Use Cooler Installation Te
Connecting Cooler and Thermostat to the Power Source
* DA-500, DA-700, DA-1000, DA-1500 - @ DA-2000C, DA-3000C Circuit breaker
DA-500N, DA-700N, DA-1000N (Internal Type) : 208-230V 3PH Only for Cooler ¡and no-fuse |
Only for Cooler Main :
Thermostat Earih Leackage Thermostat]
No-Fuse Breaker Circult Breaker
Cireulating
Pum
Broakar
208-230V 3PH
e DA-2000, DA-3000 Only for Cooler : æDA-2000C, DA-3000C 208-230V 1PH
sage (Ores or
ermosig : Earth Lea
No-Fuse Breaker Circuit Breaker
Only tor Cooler
E y : Earth Leackage
[1 No-Fuse Breaker Circull Braker.
Breaker
Main
Breaker
460V 3PH
he EE
Ace
\ ь
= E, e
or Of
How to Use Cooler
Please be sure to confirm the following instructions before requesting service.
« Symptom : The light on the thermostat is not lit.
What to Check Remedy
Check1 Are no—fuse breaker and circuit breaker shut off? * Switch on the no—fuse breaker and circuit breaker,
658802) — Is the power cord plugged into the outlet? ~~ Check the connection of the power cord. <<<
68803 Is the thermostat controller turned on? Try to press the thermostat "POWER" button. |
* Symptom : The light on the thermostat is lit, but the cooler does not work.
What to Check Remedy
, ® || the set temperature is higher than that in the aquarium,
Check! Is the temperature setting correct? thé coolér will nôt ran.
; 49 « Confirm the sel lemperalure,
a El nano sica e and re-set the temperature lower than that of aquarium,
ema Is the cooler plug connected to the power port * Connect the cooler and
in the bottom of the cooler? power porl of the thermostat to each other properly,
« Symptom : The cooler is working, but does not cool properly.
What to Check Remedy
« Check the water piping to ensure water flow
| ?
Ces Is the circulating pump connected properly? Nesta cooler ieZUR RIBA
t ; ? s Since insufficient flow of water into the cooler may lower
GE Is the cooling water flowing enough the cooling performance, ensure as much water flow as possible,
Checkd Is the cooler ventilating properly? s Ensure the hot air escapes from the cooler effectively.
« Symptom : The cooler is working, but its performance is weak.
What to Check Remedy
mie Is not the amount of water in the aquarium * Lower the water level oi the aquarium a little bit. In a hot summer, Y
—......100 great compared to the capacity of the cooler? ese evan ote ts
Check? Is the heat loss of the aquarium too great? « Protect the aquarium from direct sunlight or hot air,
Checkd Is the amount of circulating water too small? * Ensure the water flows well by replacing the circulating pump.
y t an optimal temperature,
Is the desired temperature too low compared * Se
Check 4 to the capacity of the aquarium and cooler performance? * |f you desire lower temperature, lower the water level, otherwise,
use a higher capacity cooler, ре
« Symptom : The vibration and noise of the cooler is too great.
What to Check Remedy
CC Is the floor where the cooler is fixed sloping or uneven? * Move the cooler to an even floor. )
1 DET 1
How to Use Cooler Checkup Before Requesting Service o
Turn on the thermostat controller, Mi y light Check the power cord. Check the "POWER'| .| Replace the thermostat
, on the thermosial * Also check the outlet by attemptin | with a new one
b the ‘POWER’ butt q
y pressing Ie: 70 button, | is not lit lo connect other appliance to the outlet, | (PUTton for ON/OFF. if the light is not lit.
“Check if the cooling lamp | (Is the cooling lamp lit?
'(green color) is turned on, * Check the temperature setting. >
! | Even though the set temperature | Replace the thermostat
is lit, #« The cooler starts to work after is lowered than with a new one.
the lamp flashes the
present water temperature,
for three(3) minutes, | the lamp is not lit,
In case the light
on the thermostat
Replace the thermostat
LUE cooling lamp Ch K if th with a new one if it has
the lamp flashes the cooler doesn't work yet in the thermostat has
for three minutes. ‘11 208-230V+10%, e hilo оя 230V+10%
output, there is a problem
on the cooler,
Ihe cooler is working, M The air from the front of the cooler is hot,
but ils performance
ELSE | This is because of the surrounding
the temperature circumstances rather than problems on the cooler,
is not going down ]
effectively,
. — Remove other items or change the position of the cooler,
Is the cooler effectively g p
ventilated? | e |s the amount of water in the aquarium great compared YES
* Hot air should escape and to the capacity of the cooler? : —
fresh air should come in. e |s there much heat loss due to direct sunlight
or hot air in the aquarium?
The air from the front of the cooler
is warm.
Check both the cooler and
the surrounding environment,
| 3 Pe the circulation of the > Check the
Is the cooler effectively ventilated?
circulating pump
cooling water imsufficient? and pipes.
The air from the front of the cooler
is lukewarm. = x
If the air is lukewarm in a hot summer, The a JP по!
there may be a problem on the cooler, -
Т . |*Lessen the amount of water
. YES, The cooler performance | or upgrade the capacity
Is the water effectively circulated | Is not normal. of the cooler by one level.
by the cooler? E. =
| NO Check the circulating pump
> and pipes. Request A/S.
Do you feel electricity when you touch the aquarium? (Electric leakage)
E =
r> Do you feel electricity only when the cooler is working?
‘Remove the thermostat plug from the outlet.
You should not only switch it off, but also remove the plug.
No more electricityp— Electric leakage of the cooler > Ground
= and ground.
still electricity —> No problems on the cooler — — — >, Replace related appliance
> Do you feel electricity only when the cooler is working? Unplug all appliances related
to the aquarium,
Remove the plug from the outlet, | such as the circulating pump,
E EM Ios | EUA
No more electricity-—> Problems on the cooler — Ground | E > aquarium fluorescent lamp,
a = electric heater, ozonizer, etc.
14 ‘1 1
DI Saving Energy В
> Aquarium
When installing the aquarium, avoid sunlight or heating appliances,
» Draw the curtain when sunlight comes in.
» Do not pul the aguarium around heating appliances,
«The temperature of the aquarium does not go down, but the consumption of electricity becomes increasing,
and the cooler gets overloaded.
> Cooler
When installing the cooler, choose a place with good ventilation and without direct sunlight,
When sunlight comes in, hang a cover over il.
+ Do not put the cooler in a place exposed lo heal from the kitchen, etc, It will lower the cooling performance,
= Circulating Pump
Using a circulating pump with large capacity will enable as much water as possible to circulate in the cooler,
which will result in increasing the cooling performance and decreasing electric consumption,
When Using
« Set the aquarium temperature properly,
* Since too low set temperature increases electric consumption, set an optimal temperature depending on fish,
« Good filtering device will enable purifying the aquarium water and recycling it,
* Too much dust on the condenser will lower the cooling performance, Clean it every month,
Ш Specifications
DA-2000B, C l DA- 500B, DA-1000B internal Type DA- 500N, DA-1000N
D/A. DA-15008,
Model DA-5008 | DA-7008 | DA-1000B|DA-1500BDA-2000B|DA-30008| DA-500N | DA-700N | DA-1000N |DA-2000C | DA-3000C
Power AC 208-230V 1PH 60Hz AC 208-230V/460V 3PH 60Hz
Cooling
PAY 6,000 9,000 12,000 18,000 24,000 34,000 6,000 9.000 12,000 24 000 34,000
u/hr
Compressor
(НР) 0.5 34 1 1.5 2 3 0.5 34 1 2 3
Fan un 16 66 66 100 | 66xX2EA [100X2EA| 16 66 66 66x2EA | 100x2EA
Retrigerants R— 22
Controller Thermostat Controller
conectan 1x1 14° x 147 17x 17 1447 x 14"
Weigh
(LBS) 55 77 79 | 84 126 137 44 58 80 132 143
Size a is и = 5 5 я A A a an я ; а i a
(WXDXH) 21 xX14 x15 26 x15 x19 28 X15 xX 36 15" X17 X13 18 x18 x18 2B" X 18" xX 38
The specification is subject to change for enhancement of quality and performance without prior notice.
1] The internal type cooler is specially designed and
manufactured to be installed in the aquarium according to requests from customers,
2] Free service will not be provided for such an occasion
where a distributor not authorized by Daeil installed the cooler or provided service,
3) The expenses for additional works such as wiring extension or
auxiliary switch setting will be for the account of customers.
Ш 12 Ш

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement