Summeraire Superventor Series SHRV40SD, SHRV125SD, SHRV185SD, SHRV240SD, Proventor Series SHRV120ED, SHRV180ED Heat Recovery Ventilator User manual

Superventor Series SHRV40SD, Superventor Series SHRV125SD, Superventor Series SHRV185SD, Superventor Series SHRV240SD, Proventor Series SHRV120ED, Proventor Series SHRV180ED. The device removes undesirable pollutants continuously as well as excess humidity during the heating season. The advantage offered by your HRV is that it transfers the energy from your exhausted (inside conditioned air) to temper the incoming fresh air stream.

PDF
Document
Summeraire Heat Recovery Ventilator User Manual | Manualzz

Advertisement

Advertisement

/

Advertisement

Key features

  • Continuous ventilation

  • Adjustable dehumidistat

  • Automatic defrost

  • Remote control options

  • Energy efficient

  • Reduces indoor humidity

  • Improves air quality

Frequently asked questions

Turn the HRV ON, fan speed will cycle to LOW. Continuous low speed ventilation is recommended for fresh air for building occupants. Set adjustable dehumidistat (lower left side of HRV) to off. If home feels too humid or if you have water condensation on windows Dial built-in dehumidistat (lower left side of HRV) slowly in CLOCKWISE direction until HRV fan speed changes to HIGH (green light flashes at high) and allow HRV to run in this position for 24 hours. If symptom continues, repeat previous step until humidity level is acceptable. Also, if there is a humidifier installed, check to make sure it is working and its humidistat is set properly (see humidifier manufacturer’s instructions.)

Continuous ventilation is recommended when house is being heated or cooled: For summertime operation of HRV, turn dehumidistat setting counter clockwise to off (80%), set run speed to LOW. Changing the stale indoor air with fresh outdoor air is just as important in the cooling season as it is in the heating season!

Every Six Months: Disconnect the power supply. Unlatch the door latches at top of door panel (you will have to remove latch screws first on the Proventor models only) and gently lower the door to a level position while securely holding the door panel in place (apply pressure to the RT.) (Caution - Door can slip off hinges.) Once open, hold the access door securely and slide it to the left. This will disengage the lower hinges allowing the door to be removed. Remove the filters as shown and wash in warm, soapy water, rinse, let dry and replace. Clean the HRV Core by sliding it out evenly along the channel tracks, then wash in warm soapy water, rinse, let dry and replace. To replace properly, slide the core back into the tracks with the label attached to the core indicating the top upright position of the Core, in the most top upright location. We suggest that you wear gloves when handling the Core as some edges may be sharp. Clean and inspect the condensate trays and drain hose. Observe the tray outlets and the drain hose to ensure they are clear of debris. If debris is present flush out the drain system with warm soapy water or have the hose replaced. Clean the condensate trays by wiping with a damp cloth.

Nothing works: Unit not plugged in. Lack of power. Front access door safety switch flange improperly inserted into control cover slot. Defective component. HRV front panel On/Off switch illuminates but fan is not running: Mode of operation selected set to “Auto Off”. Defective component. HRV status panel flashing HIGH continuously: HRV internal dehumidistat set too low. External dehumidistat set too low. Remote push button activated. Defective dehumidistat or push button. HRV is operating but little or no air flow is present.: Air stream blockage. Dirty air filters or heat exchanger Core. Heat exchange core frozen solid. Defective component. Poor air quality, excess moisture windows: HRV turned off. HRV running on too low a speed. If HRV is connected to furnace ductwork (both exhaust and supply.) Temporary conditions causing effect. Excessive humidity conditions within home. Indoor air temperature too low. Indoor air considered too dry: HRV set at too high a ventilation speed. Check dehumidistat settings. Adjust higher. Set to intermittent mode of operation. Temporarily use a humidifier. Add a 7/24 timer to lower ventilation rate. Excessive frost build up on ducts connected to HRV: Supply air too cold. Extreme outdoor air temperatures. Imbalance in air flow streams. Defective defrost system. Defective Vapor Barrier. Open HRV access door and defrost Core. Contact your installer. Have unit inspected for- defective sensors, check system balancing.