GDC LPU-1000 User Manual
広告
広告
USER MANUAL FOR
LPU-1000 LED PLAYER UNIT ™
[THIS DOCUMENT IS PROPRIETARY AND CONFIDENTIAL. NO PART OF THIS DOCUMENT MAY BE DISCLOSED IN ANY
MANNER TO A THIRD PARTY WITHOUT THE PRIOR WRITTEN CONSENT OF GDC TECHNOLOGY]
SMS version 10.0
Aug 01, 2018
TABLE OF CONTENTS
TABLE OF CONTENTS
User Manual for LPU-1000 LED Player Unit - 2 - 01 Aug 2018
TABLE OF CONTENTS
User Manual for LPU-1000 LED Player Unit - 3 - 01 Aug 2018
TABLE OF CONTENTS
User Manual for LPU-1000 LED Player Unit - 4 - 01 Aug 2018
TABLE OF CONTENTS
User Manual for LPU-1000 LED Player Unit
- 5 - 01 Aug 2018
TABLE OF CONTENTS
User Manual for LPU-1000 LED Player Unit - 6 - 01 Aug 2018
Thank you for purchasing a GDC LPU-1000 LED Player Unit from GDC Technology
Limited.
To ensure proper operation and to maximize value of LPU-1000, please review this User Manual. It will guide you through all the features and benefits.
COPYRIGHT NOTICE
Copyright © 2018 by GDC Technology Limited
All rights reserved. No part of this manual may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language, in a form or by any means, electronic, mechanical, photocopying, recording, magnetic, optical, manual or otherwise, or disclosed to third parties without prior written permission of GDC Technology Limited.
MANUAL DISCLAIMER
This manual is made with SMS version 10.0 and there might be slight differences depending on the software version the IMB is running. The contents, features and specifications stated in this manual are subject to change without notice due to continuous product development and improvements. In no other event shall GDC Technology Limited be liable for any loss of profit or any other commercial damages, including but not limited to special, consequential, or other damages.
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
User Manual for LPU-1000 LED Player Unit - 7 - 01 Aug 2018
CONTACTS AND OFFICES
CONTACTS AND OFFICES
Website: www.gdc-tech.com Email: [email protected]
24/7 Engineering Support Hotline:
North America
Europe
+1 877 743 2872 (Toll Free)
+34 928 912 295
North Asia
South East Asia
Hong Kong
(Headquarters)
+852 3520 0920
+65 6100 4328
China (Beijing)
Latin America
China
India
Australia/
New Zealand
China (Shenzhen)
+52 55 8851 1198
+86 400 886 0966
(Toll Free)
+91 022 4044 0500
+61 407 040 744
Spain(Barcelona)
Unit 1-7, 20th Floor,
Kodak House II,
39 Healthy Street East,
North Point, Hong Kong
Tel: +852 2507 9555
Peru (Lima)
Rm. 609-618, Office
Building,20# Xinde
Street, Xicheng
District, Beijing, P.R.
China 100088
Tel: +86 10 6205 7040
Room A701, 7/F,
Languang Technology Building,
No.7 Xinxi Road, North Zone,
HighTech Park, Nanshan District,
Shenzhen, China
Tel: +86 755 8608 6000
C/ Esteve Terradas, nº
27, esc. D, Despacho 1
08023 Barcelona, Spain
Tel: +34 93 159 51 75
USA (Los Angeles) Brazil
(São Paulo)
Singapore
Calle Manuel Miota 170,
Miraflores Lima 18, Peru
Tel: +51 1 340 5146
1016 West Magnolia
Boulevard, Burbank,
CA 91506, USA
Tel: +1 818 972 4370 /
+1 877 743 2872
(Toll Free)
Av. Antônio Carlos
Comitre, 540, 3º andar,
Conjunto 31, Campolim,
Sorocaba / São Paulo,
CEP 18047-620, Brasil
Tel: +55 15 33269301
10 Ubi Crescent,
Ubi Tech Park,
Lobby B, #06-25
Singapore 408564
Tel: +65 6222 1082
User Manual for LPU-1000 LED Player Unit - 8 - 01 Aug 2018
CONTACTS AND OFFICES
Indonesia (Jakarta) Japan (Tokyo)
Total Building Lantai 4 Suite 0401,
Jl. Letjen S. Parman Kav. 106A,
Kel Tomang, Kec. Grogol
Petamburan,
Jakarta Barat 11440, Indonesia
Tel: +62 21 2920 4691
United Arab Emirates
(Dubai)
Business Centre,
Dubai World Central,
PO Box 390667,
Dubai UAE
3F, Kyobashi-Chuo Bldg,
1-14-7 Kyobashi Chuo-ku,
Tokyo 104-0031, Japan
Tel: +81 3 5524 2607
India (Mumbai)
Office No. B-207/208,
Everest Chamber,
Andheri Kurla Road,
Marol, Andheri (East),
Mumbai-400 059, India
Tel: +91 22 4044 0500
CONTACTS AND OFFICES
Mexico
(Mexico City)
S. de R.L. de C.V.,
Av. Del penon 411 esq. Ote 168,
Col. Moctezuma 2 ª Sección,
Venustiano Carranza, Distrito Federal,
C.P. 01210 Mexico
Tel: +52 55 8526 6220
User Manual for LPU-1000 LED Player Unit - 9 - 01 Aug 2018
1. INTRODUCTION
1 INTRODUCTION
1.1 About This Manual
This user manual provides instructions on how to use and manage the GDC LPU-1000 LED Player Unit
(LPU-1000). The user interface of the media block in LPU-1000 consists of a few key components
described in the diagram below in Figure 1.
The manual has sections on each of these components describing how it can be used to operate the media block.
User Manual for LPU-1000 LED Player Unit
Figure 1: Media Block UI components
- 10 - 01 Aug 2018
1. INTRODUCTION
1.2 Safety Instructions
1.2.1 General Safety Instructions
• The LPU-1000 is intended for installation in a restricted access location.
• The operation environment required should be 0ºC - 40ºC (32ºF - 104ºF).
• For PLUGGABLE EQUIPMENT, the socket outlet should be installed near the equipment and should be easily accessible.
• Before operating your LPU-1000, please read this manual thoroughly, and retain it for future reference.
• Installation and preliminary adjustments should be performed by qualified GDC Technology personnel.
All warnings on the LPU-1000 in the documentation manual should be adhered to.
• All instructions for operating and maintaining LPU-1000 must be followed closely.
1.2.2 Electrical Safety
Safety Warning
• Do not expose the LPU-1000 to rain or moisture, to prevent fire or electrical shock hazard.
• Use a dry cloth when cleaning LPU-1000.
• Do not block any ventilation openings.
• Do not install near any heat sources (e.g. radiators, stove or other apparatus that produce heat).
• Consult Tech Support for servicing or maintaining LPU-1000.
• You are cautioned that any change or modification not expressly approved in this manual or approved in writing by an authorized representative of GDC Technology could void your warranty and/or authority to operate LPU-1000.
User Manual for LPU-1000 LED Player Unit - 11 - 01 Aug 2018
2. SMS
2 SMS
2.1 About the SMS Interface
The SMS interface is used for playback control, creating and editing playlists, scheduling. It also provides access to advanced configuration options.
2.2 Accessing the SMS Interface
Figure 2: SMS interface
1 Enter the user password to access the SMS
interface as seen in Figure 2.
- 12 - User Manual for LPU-1000 LED Player Unit 01 Aug 2018
2. SMS
2.3 Understanding the SMS Interface
2.3.1 SMS Interface
2
1
5
6
7
10
11
1
2
[ ►]
[ || ]
3
4 [ ]
User Manual for LPU-1000 LED Player Unit
[ ■]
3 8
12
4
Figure 3: SMS Interface
Play button. The [►] button starts playback when pressed and is disabled when the system is in Pause mode.
Pause button. The [ || ] button is enabled when the system is in playing or pause mode. To resume from pause simply hit the Pause button again.
Stop button. The [■] button is enabled when the system is in playing mode and stops playback when pressed.
Playlist button. Press to open the Playlist Management to create a playlist. For more information about the Playlist Management , please refer to
Section 2.3.2. Playlist Management further below.
- 13 -
13
01 Aug 2018
9
8
4
2. SMS
5
6
[Slider Bar]
[ |◄]
[ ]
[ ]
[ ►|]
It will start advancing when [►] is pressed to start a playback. One clip will take one complete cycle from the left to the right. The Slider Bar always returns to the starting point (extreme left) after a clip is finished. When
[■] is pressed, the Slider Bar will stop and return to its starting point.
When playback is paused, the Slider Bar can be moved t o t h e left (for rewinding) or to the right (for forwarding).
Move to the first frame of the clip.
Rewind (move back) by the number of frames of the playback.
Forward (move forward) by the number of frames of the playback.
Move to the last frame of the clip.
7
8
[Status Display]
[ i ]
Reports the status of the system. The display shows the number of clips in the active playlist, the name of the active playlist, and the name of the clip currently being played.
INFORMATION button. If [ i ] is pressed when the system is in stopped mode, the system will show the serial number and the software version of the IMB.
A text box will appear beside the Timecode Display (replacing the navigating buttons [| ◄] [
] [
] [►|] ) and the text box will show the serial number and software version of the IMB.
Serial
Number
9
Software
Version
SCREEN LOCK button - The SCREEN LOCK function will prevent any
[ ] unintentional screen touches or mouse clicks that could disturb playback.
The screen will be locked when [ ] button is pressed. No access to the
SMS Interface (or associated interfaces) is allowed when the screen is locked. The User level password or higher is needed to unlock the screen.
If the screen is locked while the system is playing, the name, duration and the remaining time of the clip will be shown on the screen while the clip is playing.
10 [Control Panel] CONTROL PANEL button – For returning to the control panel screen of the user interface.
11
[Scheduler]
SCHEDULER button – For scheduling the time and date of the playlists to be shown. The playlist can also be looped for a period of time. For more information about Scheduler , please refer to Section 2.3.3. Scheduler.
12
13
[Configuration]
[Shutdown]
CONFIGURATION button – For changing the general options on the system
(e.g. enable startup/ shutdown password, change access level passwords, perform software upgrade, etc.). For more information, please refer to
Section 2.3.4. Configuration .
SHUTDOWN button. For shutting down the IMB or restarting the application. For more information, please refer to
Section 2.8 Shutdown/Restart Application
- 14 - User Manual for LPU-1000 LED Player Unit 01 Aug 2018
2. SMS
2.3.2 Playlist Management
7
10
1
13
4
15 8
16
17 18
1 [IMB Content]
2
3
[Playlist Content]
[Clip
Information]
4
5 [
[ + ]
]
Figure 4: Playlist Management
14 19
The IMB content is listed here. Content is shown in alphabetical order grouped by [ Trailer, Feature, etc .]. Available automation cues are listed under cues . HDMI content can also be added to the playlist.
The contents of the playlist being currently edited are shown here.
Displays information about the selected item in the Content. This includes the Name , total Duration , Sound (Audio) format, Content format, if
Encryption is present, if a Composition Playlist exists, if it has Subtitles and if a current KDM is on the IMB.
Adds content to the Playlist by pressing [ + ] after an item from the Content is selected.
Removes the selected item from the Playlist content.
User Manual for LPU-1000 LED Player Unit - 15 -
5
01 Aug 2018
2
3
9
11
12
6
3
2. SMS
6
7
8
9
[Loop]
10 [CPL Properties]
11
[ ]
12
[ ]
[3D Sync]
[Clear]
[Edit Cue]
When [Loop] is selected, the contents in the Playlist will run continuously in a loop when [►] is pressed.
Synchronizes clips for 3D showing.
Removes all clips on the playlist.
Click the Edit Cue button to bring up the cue editing interface, used to add, remove or edit existing automation cues for the selected clip in the playlist
(See
Section 2.4.1.3 Editing Cues )
Shows the properties of selected CPL
Moves the highlighted clip in the Playlist ahead in chronological order.
Make sure an item is selected from the Playlist before pressing [ ] . When
[ ] is pressed, the selected item will move before the previous clip.
Moves the highlighted clip in the Playlist down in chronological order.
Make sure an item is selected from the Playlist before pressing [ ] .
When [ ] is pressed, the selected item will move after the next clip.
13
14
15
16
17
18
[Shows]
[Load Show To Play]
[Save Show]
[New Show]
[Delete Show]
[Copy Show]
This displays a list of all the playlists saved. Selecting a playlist here displays the contents of the playlist for editing. A playlist that is currently playing may not be edited.
NOTE: Selecting a playlist here does not load it for playback. The “ Load
Show to Play ” button has to be pressed to load the playlist into the player for playback.
Loads the selected playlist into the player for playback.
Saves the playlist currently being edited.
Creates a new blank show playlist. A name must be specified for the playlist.
Make sure an item is selected in the Shows drop-down menu. When
[Delete Show] is pressed, the system will delete the selected playlist and remove it from the Shows drop-down menu.
The delete action is irreversible. The system will prompt you to confirm the delete action before it proceeds to delete the playlist.
Duplicates currently selected playlist. When [Copy Show] is pressed, a text entry keypad will appear for you to enter the new name of the duplicate playlist.
User Manual for LPU-1000 LED Player Unit - 16 - 01 Aug 2018
2. SMS
19 [Close]
Cancel
Enter
Type in the desired name and press [Enter] to complete the action. To cancel the action and return to the previous screen, press [Cancel] .
Exits the Playlist Management and returns to the SMS Interface.
User Manual for LPU-1000 LED Player Unit - 17 - 01 Aug 2018
2. SMS
2.3.3 Scheduler
1
3
5
1
2
3
4
5
[Select Date]
[Timeline]
[Selected Schedule
Information]
[Delete Schedule]
[Previous], [Next]
[Add to Schedule]
Figure 5: Scheduler
Specifies the date and time of the schedule.
2
Displays shows scheduled on a 24-hour timeline for the date selected in
(1) .
Displays information such as name, time and duration of the selected show schedule.
Deletes the currently selected show schedule.
Navigate show schedules by going forward and backward one at a time.
(a) Select the playlist to be scheduled. The contents of the selected playlist will be displayed in the “Selected Playlist” window.
(b) Select the time for the scheduled show.
(c) To loop the show until a certain time, check
‘
Loop until
’ and select the time.
(d) If the schedule is to be repeated every day or week, check ‘ Set recurrence rules ’.
(e) Press the ‘ Add ’ button. A dialog will pop up for specifying the recurrence rules if it was checked.
4
3
User Manual for LPU-1000 LED Player Unit - 18 - 01 Aug 2018
2. SMS
1
2
3
2.3.4 Configuration
2.3.4.1 General
6
7
12
15
16
9
8
17
Figure 6: Configuration - General
19
4
5
18
10
11
13
14
20
User Manual for LPU-1000 LED Player Unit - 19 - 01 Aug 2018
2. SMS
1
2
3
4
5
[Use startup / shutdown password]
[Playlist Management
password protected]
[Automatically fix invalid show playlist]
[Reset TimeCode at end of clip]
[Skip checking assets during ingest]
There are 3 levels of users on the system - User , Technician, and
Maintenance . If this option is checked, the system will start up with a password dialog and the user will have to authenticate themselves as one of the above 3 users to start using or shut down the system.
If this option is checked, the User level will be denied the ability to edit or create any playlists. Only Maintenance and Technician level users will be able to create and edit playlists.
If this option is checked, the invalid show playlists will be fixed automatically.
If the ‘ Reset TimeCode at end of clip ’ option is selected, the timecode will reset to zero [0:0:0:0] whenever a playback ends or stops. The
TimeCode Display will reset to zero [0:0:0:0] while the Duration and
Remaining time will reset to 00 hr. 00 min. 00 sec. The Slider Bar will return to its starting point at the extreme left.
If the ‘ Reset TimeCode at end of clip ’ option is not selected, the system will retain the timecode at the point in which playback ends or stops. The Slider Bar will remain at where the playback ends or stops.
With this option checked the Digital Cinema Package assets will not be checked for their integrity, this option will reduce ingestion time but decrease the reliability of the ingestion.
[Subtitle Overlay]
6
8
9
7
[Subtitle Delay]
[Font Size]
[ASI Packet]
10
11
12
[Date Format]
[Language]
[Change User Password]
For changing the size of the font on the screen.
For more information, please refer to
Section 2.7.1 Subtitle Overlay
This option provides the ability to delay the on-screen subtitles, the delay is set in number of frames.
This option is provided to select the size of the packets (204 or 188 bytes) on the incoming ASI signal.
For changing the displayed format of the date.
For changing the user interface language.
For changing t h e User Password. When [Change User Password] is pressed, 3 prompts will appear. The first prompt is for the user to enter the old password, the second prompt is for the user to enter the new password, and the third prompt is for the system to verify the new password.
User Manual for LPU-1000 LED Player Unit - 20 - 01 Aug 2018
2. SMS
13
14
15
16
17
[Change Technician Password]
For changing the Technician Password. When [Change Technician
Password] is pressed, 3 prompts will appear. The first prompt is for the user to enter the old password, the second prompt is for the user to enter the new password and the third prompt is for the system to verify the new password.
[Change Maintenance Password]
For changing the Maintenance Password. When [Change Maintenance
Password] is pressed, 3 prompts will appear. The first prompt is for the user to enter the old password, the second prompt is for the user to enter the new password and the third prompt is for the system to verify the new password.
[SNMP Setup]
[Automation]
For accessing the SNMP Configuration Interface.
Please refer to
Section 2.3.5 SNMP Configuration.
This will bring up the automation configuration user interface used to integrate the IMB with external devices.
Please refer to
[IMB]
After connecting to the IMB the window will display the IMB version information as well as check the Marriage and Service Door status on the cinema LED screen. For IMB Marriage, please refer to the LPU-1000
Installation Manual (see Section 8.2)
18
19
20
[Use 24-hour time display format]
When this option is selected, time on the SMS interface will be displayed in
24-hour format. If this option is not selected, time on the SMS interface will be displayed in 12-hour format.
[Alternative Inputs]
[MoviePlaz Setup]
This will bring up the Alternative Inputs configuration interface. This interface can be used to configure video output formats for HDMI and SDI formats.
To setup the MoviePlaz configuration .
User Manual for LPU-1000 LED Player Unit - 21 - 01 Aug 2018
2. SMS
2.3.4.2 CineCanvas
1
2
Figure 7: Configuration - CineCanvas
1 [XYZ output for MPEG]
Check this to display XYZ video output for MPEG playback.
2 [Resolution] Allows playback of mixed 2K and 4K content at a constant resolution.
Video output will be scaled up or scaled down to the selected resolution.
Note: This feature will only affect video and will not automatically scale
PNG subtitles to the target resolution.
User Manual for LPU-1000 LED Player Unit - 22 - 01 Aug 2018
2. SMS
2.3.4.3 Assistance
1
1
2
[USB Disk]
[Server Information]
3 [Warn before warranty
/lock expired]
Figure 8: Configuration - Assistance
Press to perform software upgrades from USB Disk.
Displays serial number, OS version, software version, video capabilities of the IMB and warranty expiry date.
To set the number of days to show a warning before warranty/lock expired.
User Manual for LPU-1000 LED Player Unit - 23 -
2
4
3
4
01 Aug 2018
2. SMS
2.3.4.4 Audio Option
1
2
3
5
1 [Audio Offset]
2
3
[Audio Output]
[Audio Output
Sampling Rate]
4 [MDA Decoding]
5 [Audio Channel
Mapping]
User Manual for LPU-1000 LED Player Unit
Figure 9: Configuration - Audio
Specify the audio delay to make the video and audio in sync. ‘+x’ will move the audio x frames forward such that the audio comes earlier than before. ‘-x’ will delay the audio by x frames such that the audio comes later than before.
LTC output is always enabled on LPU-1000.
Change audio output sampling rate. Output audio sampling rate can be fixed at
48kHz or 96kHz for all content, or it can match the content’s audio sampling rate
(option ‘None’). If the output sampling rate is set to a fixed value (48kHz or
96kHz), content audio is re-sampled if it does not match the output sampling rate.
Please refer to
for the setting of MDA Decoding configuration.
Please refer to
for the setting of Audio Channel Mapping.
- 24 - 01 Aug 2018
4
4
2. SMS
2.3.4.4.1 Audio Channel Mapping
1
3
1
2
3
User Manual for LPU-1000 LED Player Unit
Figure 10: Using DCP channel order
Audio output based on the number of audio channels in the audio track of the DCP can be configured in this tab.
The preset for the number of audio channels in the audio track can be changed here.
Use the 'Preset' button to configure audio presets.
- 25 -
2
01 Aug 2018
2. SMS
1
2
3
1
Figure 11: Use DCP channel labels
Audio output based on SMPTE audio channel configuration labels can be configured in this tab,
2 Check the 'Use SMPTE audio labels' checkbox to route audio output based on SMPTE audio channel configuration labels.
3
Audio output for individual SMPTE audio channel labels can be changed here.
User Manual for LPU-1000 LED Player Unit - 26 - 01 Aug 2018
2. SMS
3
1
2
3
Figure 12: Alternative Inputs
Audio output for alternative (HDMI, SDI) inputs can be configured in this tab.
The audio output preset for each alternative input can be changed here.
Use the 'Preset' button to configure audio presets.
User Manual for LPU-1000 LED Player Unit - 27 -
1
2
01 Aug 2018
2. SMS
2
Figure 13: Upmix
1
Audio channel upmix can be enabled or disabled in this tab.
2 Check the 'Enable Upmix' checkbox to enable audio upmix.
Please refer to
for more details on audio upmix.
User Manual for LPU-1000 LED Player Unit - 28 -
1
01 Aug 2018
2. SMS
1
2
4
1
2
3
4
5
Figure 14: Audio Preset
Audio channel output presets can be configured in this tab.
Select a preset to view or change preset settings
Add a new preset or delete the current preset.
Audio configuration for an audio preset can be changed here.
Click 'Save' to save current audio configuration to the selected preset. Click 'Quit' to return to Audio
Channel Mapping configuration.
User Manual for LPU-1000 LED Player Unit - 29 -
5
01 Aug 2018
3
2. SMS
2.3.4.5 Caption
1
2
Figure 15: Configuration - Caption
1
[Rear Window Caption
Device]
Enable and configures a Rear Window display for closed captions.
Note: A USB-to-Serial converter is required for Rear Window display.
2 [Enable Device]
[Maximum waiting time]
Enable communication with a closed caption device that supports
SMPTE 430-10 (USL CCE-100, etc.).
Specifies the maximum time to wait for the closed caption device to report it is ready, before starting playback.
User Manual for LPU-1000 LED Player Unit - 30 - 01 Aug 2018
2. SMS
2.3.4.6 IMB Network
1
2
3
4
5
1
2
3
4
5
6
User Manual for LPU-1000 LED Player Unit
Figure 16: Configuration - IMB Network
[Subnet Mask]
[IMB Ethernet 2]
[SOM IP Address]
[SOM Gateway]
[Enable IMB Ethernet 1]
[Enable IMB Ethernet 3]
- 31 -
Specify the subnet for all IP addresses.
Specify the IP address of the IMB. This is the IP address of the Security Manager.
This is the main IP address of the LPU-1000. The SMS interface can be reached at this IP address using VNC.
Specify the network gateway for the LPU-1000.
Specify an IP address and Subnet Mask for IMB
Ethernet 1 of the LPU-1000. This network access can be used for Dolby Atmos connections.
Specify an IP address and Subnet Mask for IMB
Ethernet 3 of the LPU-1000. This network access can be used to connect to a Content management network.
7
6
01 Aug 2018
2. SMS
7
User Manual for LPU-1000 LED Player Unit
[Validate IPs]
- 32 -
Click to check all IP addresses entered above for correctness. A dialog will be displayed showing the source and target IP addresses, and any errors found in the new network configuration as shown below:
01 Aug 2018
2. SMS
2.3.4.7 IMB Storage
1
2
3
Figure 17: Configuration - IMB Storage
1
2
3
User Manual for LPU-1000 LED Player Unit
Specify a Network-Attached Storage System (NAS) which has an NFS share available to this
LPU-1000 system for the use as data storage
.
Configure the LPU-1000 to use an attached single external eSATA hard disk as data storage. The external eSATA hard disk must be attached to the eSATA Port 1 on the LPU-1000.
Configure the LPU-1000 to work with the Enterprise Storage. The Enterprise Storage must be attached to the eSATA Port 1 on the LPU-1000.
- 33 - 01 Aug 2018
2. SMS
2.3.5 SNMP Configuration
2.3.5.1 Introduction
The SNMP feature is an option on the LPU-1000 that enables the use of SNMP to monitor the IMB. The SNMP interface contains many useful SNMP traps and is easy to configure.
2.3.5.2 Accessing the SNMP Configuration Interface
Press Configuration to switch the display from the SMS interface to the Configuration panel as seen in
1
1
Figure 18: SNMP Setup
On the Configuration , select SNMP Setup
. A new window appears as seen in Figure 19.
User Manual for LPU-1000 LED Player Unit - 34 - 01 Aug 2018
2. SMS
1
Figure 19: SNMP Configuration
1 On the SNMP Configuration , there are several tabs along the bottom of the screen. The
General option (shown in the above figure), System Info option, System Setting option,
Encrypt option, Storage option, Video Card option, PCI option and Sensors option.
User Manual for LPU-1000 LED Player Unit - 35 - 01 Aug 2018
2. SMS
2.3.5.3 Understanding the SNMP Configuration Interface
2.3.5.3.1 General
2
3
1
4
5
0
6
Figure 20: SNMP Configuration - General
1
2
3
[SNMP Manager IP]
[Trap Sending Interval]
[System UpTime Threshold]
Indicates the IP address of the SNMP Manager where traps are to be sent by typing in the IP Address, press the + or button to insert multiple SNMP addresses.
Indicates the time interval in seconds after which a trap should be resent to the SNMP Manager. The trap will continue to be resent only as long as the error condition exists.
Indicates the threshold time in days.
NOTE: When Trap is On, a trap will be sent if the System UpTime exceeds the threshold value.
4
[SNMP Agent Start]
User Manual for LPU-1000 LED Player Unit
Check SNMP Agent Start to activate the Trap.
Un-check the SNMP Agent Start to deactivate the Trap.
NOTE: When Trap is On, a trap is sent if the SNMP Agent is started.
- 36 - 01 Aug 2018
2. SMS
5
6
[SNMP Agent Stop]
[Enable SNMP Service]
Check SNMP Agent Stop to activate the Trap.
Un-check the SNMP Agent Stop to deactivate the Trap.
NOTE: When Trap is On, a trap is sent if the SNMP Agent is stopped.
Enable or disable SNMP monitoring and reporting using this checkbox.
2.3.5.3.2 System Information
Figure 21: SNMP Configuration
– System Information
1
2
3
[Auditorium Number]
[System Name]
[System Location]
The auditorium where the LPU-1000 is installed. This value will be displayed when SNMP information is queried.
The name of the Server. This value will be displayed when
SNMP information is queried.
This will be automatically set to the server model if the
Automatically set System Name to Server model option is checked.
The location where the LPU-1000 is installed. This value will be displayed when SNMP information is queried.
User Manual for LPU-1000 LED Player Unit - 37 -
3
4
5
1
2
01 Aug 2018
2. SMS
4 [System Description]
5 [Contact Details]
A brief description of the server. This value will be displayed when SNMP information is queried.
Contact details to be displayed when SNMP information is queried.
2.3.5.3.3 System Setting
2
1
1
[Ingestion Start]
[Ingestion Complete]
[Ingestion Fail]
[Dropped Frame]
[KDM Invalid]
User Manual for LPU-1000 LED Player Unit
Figure 22: SNMP Configuration - System Setting
When this option is checked, an SNMP trap will be generated when a DCP ingest starts.
When this option is checked, an SNMP trap will be generated when a DCP ingest is completed.
When this option is checked, an SNMP trap will be generated when a DCP ingest fails.
When this option is checked, an SNMP trap will be generated when the playback has dropped frames
When this option is checked, an SNMP trap will be generated when we try to play a playlist containing CPL without a valid
KDM
- 38 - 01 Aug 2018
2. SMS
2 [Dropped Frame Threshold]
Set a threshold limit based on the number of frames dropped in the specified time period (in seconds)
2.3.5.3.4 Encrypt
1
Figure 23: SNMP Configuration - Encrypt
1 [Enable Authentication]
Allows user to enable SNMP Authentication by providing
Username . The default Password can be changed using the
Change button. This option is unchecked by default.
Note: The new password should be at least 8 characters long.
User Manual for LPU-1000 LED Player Unit - 39 - 01 Aug 2018
2. SMS
4
5
6
1
2
1
2.3.5.3.5 Storage
3
Figure 24: SNMP Configuration - Storage
[Storage]
On the SNMP Configuration , select Storage . A new window opens as
above.
2
3
4
[HDD Missing and SMART Error]
Check the corresponding storage devices to activate the Trap.
NOTE: When Trap is On, a trap will be sent to the SNMP Manager if the system cannot detect the specified device.
[HDD Temperature Threshold]
[RAID Device missing and degraded status]
Set the desired threshold temperature for respective storage device by using the [▲] and [▼] buttons. Activate the Trap by checking the checkbox opposite the corresponding storage device.
NOTE: When t he Trap is On, a trap will be sent to the SNMP
Manager when the threshold temperature is reached.
Activate the Trap by checking the checkbox opposite RAID Device .
NOTE: When t he Trap is On, a trap will be sent if the
RAID Device is missing or degraded.
5
[Mount Data Storage]
User Manual for LPU-1000 LED Player Unit
Activate the Trap by checking the checkbox opposite Mount Data
Storage .
NOTE: When t he Trap is On, a trap will be sent if the data storage is not mounted on the system.
- 40 - 01 Aug 2018
2. SMS
6 [Mount Capacity Threshold (for data in %)]
Set the threshold mount capacity of the mount data storage by typing in the field or using the on-screen keyboard the Trap by checking the checkbox.
. Activate
NOTE: When t he Trap is On, a trap will be sent to the SNMP
Manager if the mount capacity exceeds the threshold value.
2.3.5.3.6 Video Card
2
1
Figure 25: SNMP Configuration - Video Card
1
2
1
1
2
On the SNMP Configuration , select Video Card . A new window opens as seen in
above.
Activate the Trap by checking the checkbox opposite Video Card Driver JPEG2000 .
NOTE: When t he Trap is On, a trap is sent to the SNMP Manager when the video card driver is not loaded.
User Manual for LPU-1000 LED Player Unit - 41 - 01 Aug 2018
2. SMS
2
2.3.5.3.7 PCI
Figure 26: SNMP Configuration - PCI
1
1
2
On the SNMP Configuration , select PCI
. A new window opens as seen in Figure 26
above.
Activate the Trap by checking the checkbox opposite the corresponding PCI Device .
NOTE: When t he Trap is On, a trap is sent when the corresponding PCI device is missing.
User Manual for LPU-1000 LED Player Unit - 42 - 01 Aug 2018
2. SMS
2
2.3.5.3.8 Sensors
1
Figure 27: SNMP Configuration - Sensors
1
2
On the SNMP Configuration , select Sensors . A new window opens as seen in
above.
Set the threshold temperature required for the system sensors by typing in the field or using an on-screen keyboard . Activate the Trap by checking the checkbox opposite System
Temperature Threshold .
NOTE: When t he Trap is On, a trap is sent if the system temperature exceeds the maximum threshold temperature.
User Manual for LPU-1000 LED Player Unit - 43 - 01 Aug 2018
2. SMS
2
2.3.5.3.9 Ethernet
Figure 28: SNMP Configuration - Ethernet
1
1
2
On the SNMP Configuration , select Ethernet . A new window opens as seen in
above.
Enables sending an SNMP trap if the system detects that either eth0 or eth1 network interface is down.
User Manual for LPU-1000 LED Player Unit - 44 - 01 Aug 2018
2. SMS
2.3.5.3.10 Restart/Save/Cancel
1
2
Figure 29: Pop-up window for restarting SNMP service
1
2
(a)
User Manual for LPU-1000 LED Player Unit
After the settings are complete, press OK to confirm. A small window pops out asking if you want to save the current SNMP configuration: a) Select OK to save the configuration. b) Select Cancel to cancel the configuration
(a)
(b)
.
Press Cancel if you want to cancel the operation. A small window pops out to confirm if you want to quit without saving:
c)
Select Yes if you want to confirm.
d)
Select No if you want to cancel the operation
- 45 -
(b)
01 Aug 2018
2. SMS
2.3.6 Automation
Please refer to
to understand how transit from Configuration to Automation.
Figure 30: GDC Automation workflow
User Manual for LPU-1000 LED Player Unit - 46 - 01 Aug 2018
2. SMS
2.3.6.1 Devices
Automation Device Setup
It should be noted that automation will only be executed within a playlist as long as that playlist is playing.
If playback stops or the Stop button is pushed automation will not run.
2 4
1
4
Figure 31: Automation - Devices
1 On the Automation , press Devices . In the Devices , the System is the default device name.
The System device is the IMB from which all received commands will be forwarded to the sub-systems in the IMB. (continued on next page)
6
User Manual for LPU-1000 LED Player Unit - 47 - 01 Aug 2018
2. SMS
2 To add a new device, press Add . A new window appears as seen in. Type in the name you want to assign to a particular device.
Provide a name for the device (for example: “ LED ”) & select the
Type as ‘ NETWORK SOCKET’
3
3
4
After adding the device name, assign the type of device you want to use. Select from a dropdown list as seen below.
You can edit or delete the device name on the dropdown list in the Devices
(please refer Figure 31 ). The device configuration window opens when you press
Edit to edit the existing device name. The device name is deleted immediately after pressing Delete .
5
User Manual for LPU-1000 LED Player Unit
Figure 32: Editing the automation device settings
- 48 - 01 Aug 2018
2. SMS
5
Select the ‘ LED’ Device created in (2) from the Device Name drop-down list.
Under the Network and Control Cues Settings: a) The parameters such as IP address & Port of the selected device will already have default values. b) The status of the device can be Enabled or Disabled . Select from the dropdown list as seen below: c) The Linefeed Type can be selected from the dropdown list as seen below: d) Use the Edit Control Cues option to Add or Remove the control cues:
6 To search f o r a d e vic e, click the Search Devices on Network button. This will scan the network for available devices. Once discovered, select the device and press Add .
User Manual for LPU-1000 LED Player Unit - 49 - 01 Aug 2018
2. SMS
1
2
2.3.6.2 Inputs
2
2
Figure 33: Inputs
1 Press the Inputs
tab. A new window opens as seen in Figure 33 . On the
Inputs , press
Add to enter the selected device.
NOTE: Only devices capable of sending a signal to the IMB can be added under Inputs.
(a) Select a Trigger event from the dropdown
(b) Select an event Label from the dropdown list. See the Actions .
2 Press Delete if you want to delete the selected input.
User Manual for LPU-1000 LED Player Unit - 50 - 01 Aug 2018
2. SMS
2
2.3.6.3 Actions
1
3
4
1 Select Actions on the Automation . On the Actions , press Add , located at the top portion of the screen. An on-screen keyboard opens. Type in your desired label name and press Enter .
5
6
User Manual for LPU-1000 LED Player Unit - 51 - 01 Aug 2018
2. SMS
2 Press Add, located at the lower portion the screen, to append an action to the selected Event
Label. Then select a device from the dropdown list as seen below. New devices can be added to the list from the Devices.
Figure 34: Actions a ) If the selected device is System , the Output Type prompt is
Primitive. The Pins To Use option is disabled.
Then select the desired operation under the Value option.
(b) If the device type LED , the Event Action can be selected from the dropdown list:
User Manual for LPU-1000 LED Player Unit - 52 - 01 Aug 2018
2. SMS
3 To edit an existing label ’s name, select the label from the dropdown list and then press Edit . An on-screen keyboard opens. Edit the existing label name and press Enter . To use an existing label to copy to another label, select the label to be copied from the dropdown list and then press
Copy . Then enter a new label name for the newly copied label .
To delete an existing label, select the label name from the dropdown list and then press Delete .
4
5
6
Press Save after completing the settings to return to the Playlist Management .
By pressing the Execute button you can test if an automation command is working correctly.
This button will trigger the event selected.
Automation for events can be scheduled. To access the automation schedule, select the
[Schedule] button. This will bring you to a setup screen.
To add an Automation Schedule, select the [Add] button. Select the repeat interval, options are either daily or a single occurrence.
User Manual for LPU-1000 LED Player Unit - 53 - 01 Aug 2018
2. SMS
2.3.6.4 Options
3
Figure 35: Options
1
2
[Startup Label]
[Error Label]
3 [Interrupt timer delays when player is unpaused]
4 [Quick Mode Label]
Select a specific automation cue which will be executed when the server fully boots up
Select a specific automation cue which will be executed whenever a playback error occurs.
When this option is selected and the user clicks Unpause button on the player, the next action in the automation cue will be executed immediately without waiting for the Timer delay to complete.
Enables selection of a specific automation cue which can be triggered quickly using the Execute button under Quick Mode
Label → Trigger tab.
1
2
4
User Manual for LPU-1000 LED Player Unit - 54 - 01 Aug 2018
2. SMS
2.3.6.5 Import/Export
Figure 36: Import/Export
1
2
[Import/Export Device]
[Import/Export Configuration]
Import opens a pop-up window which allows the user to select a configuration file for the selected automation device.
Export automatically saves the configuration file for the selected automation device to your web browser’s default download location.
Import allows user to select configuration file containing all automation cues from an alternate server
Export automatically saves the configuration file containing all automation cues to your web browser’s default download location.
1
2
User Manual for LPU-1000 LED Player Unit - 55 - 01 Aug 2018
2. SMS
2.4 Show Playlist
2.4.1 Create a Show Playlist
2.4.1.1 Access to Playlist Management
Figure 37: Creating a show playlist
1 On the SMS interface, press [ ] to open a Playlist Management
for creating playlists as seen in Figure 38
below.
1
User Manual for LPU-1000 LED Player Unit - 56 - 01 Aug 2018
2. SMS
1
2.4.1.2 Creating a Playlist
2
1
4
Figure 38: Playlist Management
1
2
3
4
Under the Playlist Management screen, all compositions stored are listed in the Content column on the left. The content is shown in alphabetical order grouped by type [Trailer,
Feature, etc.]. Available automation cues are listed under ‘ cues ’.
Select the composition to add to the playlist and press [ + ] . Repeat the same step to add other compositions (e.g. trailers or advertisements) to the playlist.
Compositions in the playlist are shown in the Playlist column on the right. Use [ ] (move up) and
[ ] (move down) to change the order of compositions in the playlist. The order of the compositions in the playlist may also be changed by dragging their icons in the timeline display.
You can remove compositions from the Playlist column by selecting the clip that you want to remove and pressing [ - ] .
3
1
User Manual for LPU-1000 LED Player Unit - 57 - 01 Aug 2018
2. SMS
2.4.1.3 Editing Cues
Figure 39: Playlist Management - Editing Cues
1 To edit a cue of a composition on the playlist, select the desired composition from the Playlist
Management and press Edit Cue . A new window displaying the Edit Cue opens as seen in
1
1
User Manual for LPU-1000 LED Player Unit - 58 - 01 Aug 2018
2. SMS
2
6
5
7
4
3
Figure 40: Cue Editor
4
8
4
User Manual for LPU-1000 LED Player Unit - 59 - 01 Aug 2018
2. SMS
2
To specify a time code for the activation of the cue, press and a time code entry window will o pen . Use the [▲] and [▼] buttons enter the desired time code. Press OK to confirm your selection.
To specify a frame for the activation of the cue, press the Time button once and it will toggle to display the Frame button as shown below:
Press and a frame number entry window will open. Key in the desired frame number and press Enter .
User Manual for LPU-1000 LED Player Unit - 60 - 01 Aug 2018
2. SMS
3 Press Marker to view any markers present in the composition.
If the composition does not contain any markers, a small window pops up to indicate that there are no markers present.
4 To add an automation cue label, select the desired automation cue label from the dropdown list as seen below:
5 To add a start cue, tick the Start Cue option and select the desired automation cue label from the dropdown list as seen below:
To specify the blank time, press desired blank time and press Enter .
and a blank time entry window will open. Key in the
User Manual for LPU-1000 LED Player Unit - 61 - 01 Aug 2018
2. SMS
6
7
8
NOTE: A start cue is activated immediately before the composition plays. The blank time indicates the time interval between the end of the start cue and the start of the composition ’s playback.
Press Add Cue to add the cue to the composition.
The cue
’s details will then be displayed in the cue window as seen below
NOTE: You can select a cue from the cue window at any time to edit its properties.
To delete a cue from the composition, select the cue from the cue window and press Delete
Cue .
To save the changes and exit, press OK .
To exit without saving any changes, press Cancel .
User Manual for LPU-1000 LED Player Unit - 62 - 01 Aug 2018
2. SMS
2.4.1.4 Saving the Playlist
1
1
2
Figure 41: Saving the playlist
Press Save Show to save the playlist. This ensures any changes to playlist will not be lost.
Note : The Save Show button will remain greyed out until any changes are made to the selected playlist.
Press Load Show to Play and return to the SMS Interface .
2
2
User Manual for LPU-1000 LED Player Unit - 63 - 01 Aug 2018
2. SMS
2.5 Show Schedule
2.5.1 Schedule a Show
1
Figure 42: SMS Interface [Scheduler]
1 On the SMS Interface, press Scheduler
. A new window opens as seen in Figure 43
.
User Manual for LPU-1000 LED Player Unit - 64 - 01 Aug 2018
2. SMS
2
2
Figure 43: Scheduler
Go to the bottom section named Add to Schedule . At Date / Time , indicate the date and time to schedule the show.
(a) The date format is DD/MM/YYYY and the time format is HH:MM: SS.
To select the day, click on DD and adjust to the required day using [▲] and [▼] . Repeat the same for MM, YYYY, HH, MM and SS
(b) At Shows , select the playlist for the show. Press to view all the playlists already saved in the IMB. Select the required playlist.
(c) The Selected Playlist column on the right displays the clips in each playlist.
User Manual for LPU-1000 LED Player Unit - 65 - 01 Aug 2018
2. SMS
(d) If you want the playlist to loop for a period of time, check Loop Until and indicate the date and time to end the loop. e) Press Add after the schedule date/time is fixed and playlist is selected.
(f) If the new show schedule does not conflict with other schedules already saved to the IMB, the schedule will be added to the existing list of schedules in the IMB.
User Manual for LPU-1000 LED Player Unit - 66 - 01 Aug 2018
2. SMS
3
4
3
Figure 44: Viewing schedule information
Check the Enable Scheduler checkbox to enable scheduled playback
User Manual for LPU-1000 LED Player Unit
(a) At Select Date , indicate the date of the schedule. You should see a line on the time-bar at the slot where the show is scheduled.
(b) Click on the line. Information about the show such as name, time and duration will be displayed in the Selected Schedule Information column beneath the time-bar.
- 67 - 01 Aug 2018
2. SMS
4
(c) To navigate to the previously scheduled show just before the selected show, press [Prev] .
(d) To navigate to the succeeding show scheduled after the selected show, press
[Next] . (e) To delete a show schedule from the time-bar, just click on the relevant color bar and press [Del. Schedule] .
To replicate the same show schedule on other days, check Set recurrence rules and press Add .
5
6
Figure 45: Replicating show schedule
5
A new window opens as seen in Figure 45
6
Press Apply recurrence rules to schedule the recurrence dates. If no option is selected, press
User Manual for LPU-1000 LED Player Unit - 68 - 01 Aug 2018
2. SMS
2.6 Synchronizing Shows
PLEASE NOTE
: This section has been intentionally deleted as this option is not applicable to the LPU-1000.
2.7 Subtitle Setting
There are several points to be noted when setting up the GDC IMB with cinema LED screen. SMS version 10.0 supports cinema LED screen. If any fields are left blank, the default values are assumed. Login and password fields only need to be entered if the user has changed these parameters on the cinema LED screen.
2.7.1 Subtitle Overlay
2.7.1.1 Subtitle Overlay Setup
1
2
Subtitle Overlay is supported for 2D JPEG2000 content.
To setup Subtitle Overlay go to SMS -> Configuration -> Maintenance Access -> General.
Under Settings there is a box titled Subtitle Overlay. You can also enter a Subtitle Delay in number of frames, entering a negative number will advance the subtitles by that number of frames.
User Manual for LPU-1000 LED Player Unit - 69 - 01 Aug 2018
2. SMS
2.7.1.2 Subtitle Language Selection
1
Figure 46: SMS Interface [Control Panel]
1 Press the Control Panel Button to navigate to the Control Panel.
User Manual for LPU-1000 LED Player Unit - 70 - 01 Aug 2018
2. SMS
2
Figure 47: Manage Content
2
From the Control Panel select Manage Content .
User Manual for LPU-1000 LED Player Unit - 71 - 01 Aug 2018
2. SMS
3
4
5
3
Figure 48: Editing the subtitle language
Select the Subtitle tab to change the subtitle language.
When subtitle overlay is selected, the language for clips with subtitles can be configured in the
Content Manager
Setting the correct language for subtitles will ensure that subtitles will be rendered properly for each clip.
Press Edit and enter the maintenance password to change the language for the displayed clips.
5
4
User Manual for LPU-1000 LED Player Unit - 72 - 01 Aug 2018
2. SMS
6
Figure 49: Subtitle language options
6 As shown in
Figure 49 , the following languages can be set for each clip:
• Simplified Chinese
• Traditional Chinese
• Korean
• Japanese
• English
• Spanish
• Italian
• Russian
• French
The language setting can also be left as Default to automatically use the original language setting of the clip content.
User Manual for LPU-1000 LED Player Unit - 73 - 01 Aug 2018
2. SMS
7
Figure 50: Returning to Control Panel
Click the Control Panel button to return to the Control Panel.
User Manual for LPU-1000 LED Player Unit - 74 -
7
01 Aug 2018
2. SMS
2.8 Shutdown/Restart Application
2.8.1 Shutdown or Restart
Figure 51: Shutting down the system
1 On the SMS interface, when the Shutdown button is pressed, the system will prompt the user to select shutdown or restart application. Restarting the application will not reboot the IMB. It will only restart the software without affecting the hardware.
Allow some time for the IMB to restart the application or shutdown properly.
1
2
User Manual for LPU-1000 LED Player Unit
If the Use startup/shutdown password option on the Configuration/General is enabled, the system will prompt for a password before it shuts down.
Please enter the Technician or Maintenance Access password.
- 75 - 01 Aug 2018
3. CONTROL PANEL
3 CONTROL PANEL
3.1 About Control Panel
The
Control Panel
UI provides access to all the other interfaces used to configure and operate the LPU-
1000. To get to the
Control Panel
, press
Control Panel
button on the
SMS
interface
Figure 52: Accessing the Control Panel
- 76 - User Manual for LPU-1000 LED Player Unit 01 Aug 2018
3. CONTROL PANEL
3.2 Introduction to the Control Panel interface
1
User Manual for LPU-1000 LED Player Unit
Figure 53: Introduction to the Control Panel interface
1 Switch ON the IMB and allow it to boot up t o t h e l o g i n w i n d o w to the SMS interface.
When the SMS interface is shown, press the Control Panel button and a new window for the
Control Panel opens as shown in
Control Panel includes the Automation button ,
Admin panel button, Manage Content button, SMS button, Restart button, Shut Down button and a Refresh status button. System information including the serial number, OS version, SMS version, network and storage information can also be seen on the Control Panel UI.
NOTE: The Refresh status button is used to manually refresh the status of the hard disks in the external storage device. This button should not be pressed during playback to prevent disruption of playback.
The SMS software continues to run in the background when using the Control Panel. This allows access to other IMB functions when playback is in progress. It is recommended that these functions be used very sparingly to avoid unnecessary system load that can potentially affect playback performance.
- 77 - 01 Aug 2018
3. CONTROL PANEL
3.3 Manual Automation Execution
Figure 54: Accessing Automation
1 Automation labels and LED Screen commands can now be executed from an interface on the Control Panel. Press Automation on the Control Panel to start the manual automation
interface as shown in Figure 55.
User Manual for LPU-1000 LED Player Unit - 78 -
1
01 Aug 2018
3. CONTROL PANEL
2
Figure 55: Executing Automation
Select an automation label to view the actions associated with the label.
Press Execute to execute the automation label.
2
User Manual for LPU-1000 LED Player Unit - 79 - 01 Aug 2018
3. CONTROL PANEL
3.4 Restarting the Control Panel
1
Figure 56: Selecting Restart on the Control Panel
1
Press Restart to restart the Control Panel. The Control Panel will restart and display the SMS
interface as seen in Figure 57.
User Manual for LPU-1000 LED Player Unit - 80 - 01 Aug 2018
3. CONTROL PANEL
User Manual for LPU-1000 LED Player Unit
Figure 57: SMS interface
- 81 - 01 Aug 2018
3. CONTROL PANEL
3.5 Shutting Down the System
Figure 58: Shutting down the system
1
2
Select Shutdown on the Control Panel.
A small window appears as seen in
Shutdown to continue shutdown of IMB or
Cancel to cancel shutdown of IMB. All current playback will be stopped upon shutdown of the system.
WARNING: If current playback is still running in the background, it will be terminated once the
IMB is shutdown. Please use with CAUTION .
2
1
User Manual for LPU-1000 LED Player Unit - 82 - 01 Aug 2018
4. CONTENT MANAGER
4 CONTENT MANAGER
4.1 About the Content Manager
4.1.1 Introduction
The LPU-1000 Content Manager allows the user to manage the contents of the IMB in the following ways:
1
2
3
4
Download content from a disk or source on the network.
Download keys [KDM
’s] required for playing back content from disk or source on the network.
Delete content that exists in the IMB data storage.
Check that the content that is already on the IMB is fine and the files are complete and proper.
4.1.2 Accessing the Content Manager
2
Figure 59: Accessing the Content Manager
User Manual for LPU-1000 LED Player Unit - 83 - 01 Aug 2018
4. CONTENT MANAGER
1 Press Control Panel on the SMS Interface.
2 Press Manage Content to go to the Content Manager .
NOTE: The Content Manager can run in the background and does NOT need to be exited.
4.2 Content Management
4.2.1 Ingesting Content
7 9
1
8
6
2
Figure 60: Ingesting a package or CPL from a source located in a specific directory in the network
User Manual for LPU-1000 LED Player Unit - 84 - 01 Aug 2018
5
3
4
4. CONTENT MANAGER
1
2
3
4
5
6
7
8
9
Select the source of data you want to ingest content from and click Open .
Please refer to
Section 4.5 Source Management configure the source of data.
Browse the source and select the directory where the package is located. The list of packages in the directory will be displayed in the top right section of the screen.
Click View CPL to display the list of CPLs available in the packages. You can use this button to toggle between the package list and CPL list displayed in the top right section of the screen.
Click under the Transfer? column to select the package or CPL you wish to download. A green check
✓
indicates a selected package or CPL. You can select multiple packages or CPLs.
Information about the selected package or CPL, including the file size, is shown in the section below the package or CPL list.
Press Import to queue downloading of the package or CPL. (To bypass ingestion for direct playback you can press Live Play instead. Refer to Live Play below for more info.)
When done selecting the package(s), click the Close button.
IMPORTANT: Always press Close after you are done starting the download of content. You can monitor the progress of ingest by pressing the Status
button. Please refer to Section 4.2.4
for more information about Status .
Live Play can be used instead of Import in order to bypass content ingestion and play directly back from network source. This is not supported through USB but can be used for direct playback through network source (provided the network source has sufficient bandwidth to stream the content).
IMPORTANT: You should always use Import whenever possible.
When you press the Live Source button you can view all clips currently mounted and available through the Live Play feature. You can detach Live Play sources through this interface as well.
You should always detach live play sources whenever you are done using them via Live Play .
User Manual for LPU-1000 LED Player Unit - 85 - 01 Aug 2018
4. CONTENT MANAGER
4.2.2 Ingesting Content from USB Disk
1
Figure 61: Opening a USB disk connected to the IMB
1 Select USB drive from dropdown list and click Open . (Continued on next page)
User Manual for LPU-1000 LED Player Unit - 86 - 01 Aug 2018
4. CONTENT MANAGER
2
3
2
3
Figure 62: Selecting the USB storage device and its partition
Select a storage device and its partition from the dropdown lists.
Press OK to confirm the selection.
3
User Manual for LPU-1000 LED Player Unit - 87 - 01 Aug 2018
4. CONTENT MANAGER
4.2.3 Ingesting KDMs
6
1
2
5
5
Figure 63: Ingesting KDM from a directory in the selected source
1
2
3
4
5
6
Select the directory in the selected source where the KDM is located.
Shows the KDMs present in the selected directory that are valid for this IMB.
Click under the Transfer column to select the KDM you wish to download. A green check
✓ indicates the selected KDM.
Shows the details of the selected KDM, including target, CPL, and date of validity.
Press Import to start the import of the KDM. The green check will change to Queued .
When done selecting the KDM, press Close to close the Package Browser.
4
5
3
User Manual for LPU-1000 LED Player Unit - 88 - 01 Aug 2018
4. CONTENT MANAGER
4.2.4 Monitor Ingest Progress
1
2
1
Figure 64: Monitoring the progress of download of the packages
1
2
Select the Status option.
Shows the download status of the packages or CPLs. In this example, downloading of some packages or CPLs is incomplete.
2
1
User Manual for LPU-1000 LED Player Unit - 89 - 01 Aug 2018
4. CONTENT MANAGER
4.2.5 Cancelling Ingest
1
2
3
1
2
3
4
Figure 65: Content Manager - Status
Press Pause to temporarily stop the download of the package(s) or CPL(s). The Pause button will change to Start and will indicate that the download is being paused.
Use the Move Up and Move Down buttons to move the highlight bar up and down to select the desired package or CPL when multiple packages or CPLs are being downloaded. You can only move the highlighted bar to select the package or CPL when in Pause mode.
To cancel the download, select the desired package or CPL and press Remove .
If you wish to resume download, press Start button to resume the download.
- 90 - User Manual for LPU-1000 LED Player Unit 01 Aug 2018
4. CONTENT MANAGER
4.2.6 Deleting Content
1
2
Figure 66: Deleting a downloaded package or CPL
4
1
2
3
To delete a package or CPL, go to Content and click under the Select column opposite the package or CPL you want to delete. A green check
✓
indicates the selection.
Click View CPL to toggle between the package and CPL lists displayed in the content interface.
You can select all by clicking the Select All button and deselect by clicking the Deselect All button.
4 Press Delete to delete the selected package or CPL. A small window pops up to confirm the deletion of the package. Press OK to confirm.
3
User Manual for LPU-1000 LED Player Unit - 91 - 01 Aug 2018
4. CONTENT MANAGER
4.2.7 Checking Content Integrity
1
2
2
3
2
Figure 67: Verifying the integrity of the files in the package(s) or CPL(s)
1 Click View CPL to toggle between the package and CPL lists displayed in the content interface. Click
2 under the Select column opposite the package or CPL you want to verify. A green check indicates the selection.
Select if you want to verify Now or on a Schedule .
User Manual for LPU-1000 LED Player Unit - 92 - 01 Aug 2018
4. CONTENT MANAGER
3 Press Verify to check if all the required files are present in the selected package(s) or CPL(s).
(a) If Now is selected, the package will be verified immediately as seen below.
(b) If Schedule is selected, you need to assign a name and schedule the time and date when to verify the package(s) or CPL(s) in a new window as seen below.
(c) You can select the frequency of verification.
User Manual for LPU-1000 LED Player Unit - 93 - 01 Aug 2018
4. CONTENT MANAGER
4
4
Figure 68: Checking for stray files in package(s) or CPL(s)
4 You can check if there are stray files in the selected package(s) or CPL(s) by pressing Check
Stray . A small window pops out to confirm if there are no stray files.
User Manual for LPU-1000 LED Player Unit - 94 - 01 Aug 2018
4. CONTENT MANAGER
5
Figure 69: Package [Quick Verify]
5
6
Select Quick Verify to quickly check the integrity of the files in case it is modified or corrupted by calculating hash for each file in the selected package(s) or CPL(s).
You will see OK under the Status column after verifying that no problems are detected. If errors
are found, the description of the error will be shown instead as seen in Figure 69
above.
NOTE: If there is an error in the selected package, it will indicate Failed under the Status column.
6
User Manual for LPU-1000 LED Player Unit - 95 - 01 Aug 2018
4. CONTENT MANAGER
7
8
9
Figure 70: Content Manager [Schedule]
7
8
9
You can view the list of package(s)/CPL(s) that you have scheduled for verification by selecting the Schedule option.
Select the desired package or CPL and press
Select the desired package or CPL and press
User Manual for LPU-1000 LED Player Unit
View
- 96 - to see its schedule details.
Remove to delete it from the schedule list.
01 Aug 2018
4. CONTENT MANAGER
4.3 KDM Management
4.3.1 Manage KDM 1
2
3
5 6
Figure 71: KDM Manager
4
5
6
1
2
3
Select the KDM tab in the Content Manager
Show the KDM
’s present in the selected directory that are valid for this IMB.
Show the details of the selected KDM, including target, CPL, UUID and date of validity.
Display date of issue for KDM.
Verify the integrity of the KDM.
Delete removes KDM from the IMB.
User Manual for LPU-1000 LED Player Unit - 97 -
4
01 Aug 2018
4. CONTENT MANAGER
4.4 License Management
4.4.1 Manage Licenses 1
2
4
3
Figure 72: License Manager
1
2
3
4
Select the License tab in the Content Manager.
Shows the licenses that are valid for this system.
Shows the details of the selected license, including licensed feature and validity period.
Verify the integrity of the selected license.
User Manual for LPU-1000 LED Player Unit - 98 - 01 Aug 2018
4. CONTENT MANAGER
4.4.2 Ingesting Licenses
1
2
6
5
Figure 73: Ingesting license from a directory in the selected source
1
2
3
4
5
6
User Manual for LPU-1000 LED Player Unit
Select the directory in the selected source where the license is located.
Shows the licenses present in the selected directory that are valid for this IMB.
Click under the Transfer column to select the license you wish to download. A green check
✓ indicates the selected license.
Shows the details of the selected license, including feature and date of validity.
Press Import to start the import of the license. The green check will change to Queued.
When done selecting the license, press Close to close the Package Browser.
- 99 -
3
4
01 Aug 2018
4. CONTENT MANAGER
4.4.3 Monitor Ingest Progress
1
2
1
2
Figure 74: Monitor the progress of download of the packages
Select the Status option.
Shows the download status of the packages or CPLs. In this example, downloading of some LDMs is complete.
User Manual for LPU-1000 LED Player Unit - 100 - 01 Aug 2018
4. CONTENT MANAGER
4.5 Source Management
4.5.1 Adding a Data Source 1
2
Figure 75: Content Manager [Source]
1
2
You can add a new source or edit an existing source by selecting the Source option.
To add a new source, enable the source name entry and source information entry by pressing
Add . The Add button will then change to the Save button as seen in Figure 76 on the next page.
User Manual for LPU-1000 LED Player Unit - 101 - 01 Aug 2018
4
4. CONTENT MANAGER
3
5
Figure 76: Content Manager
– Setting the data source parameters
3 Type in the new data source name on the Source Name entry.
NOTE: You can type on each entry using an external keyboard or by using the on-screen keyboard .
The on-screen keyboard is normally used when an external keyboard is not present.
User Manual for LPU-1000 LED Player Unit - 102 - 01 Aug 2018
4. CONTENT MANAGER
4 Set the parameters of the source. Select the type of source from a dropdown list.
User Manual for LPU-1000 LED Player Unit
5
Type in the server name (source IP), source directory (source path), username and password of the selected source.
NOTE:
1. For sources such as FTP and CIFS , the Source IP, S ource P ath, Username and Password are enabled. The username and password are optional provided that the data source is not protected by username and password. For example, some window shares can be accessed without username and password, while other window shares need a username and password.
2. For source such as NFS , only the Source IP and Source Path are enabled.
The username and password entries are disabled.
3. For sources such as IEEE 1394 , USB 2.0
, Local directory , all entries are disabled since they are not necessary.
Press Save to save all settings.
- 103 - 01 Aug 2018
4. CONTENT MANAGER
4.5.2 Deleting a Data Source
1
2
Figure 77: Deleting a previously saved data source
1
2
Select the data source you want to delete from the dropdown list.
Press Delete to delete the selected data source.
User Manual for LPU-1000 LED Player Unit - 104 - 01 Aug 2018
4. CONTENT MANAGER
4.5.3 Editing a Data Source
1
2
Figure 78: Editing a new data source
1
2
To edit an existing source, select the data source you want to edit from the dropdown list.
Press Edit to edit the selected data source. Add and Edit buttons will change to Save and
Cancel .
User Manual for LPU-1000 LED Player Unit - 105 - 01 Aug 2018
3
4. CONTENT MANAGER
4
3
Figure 79: Editing the parameters of the selected data source
You can edit/change the source name, parameter settings, username, or password by
.
4 typing on each entry using an external keyboard or an on-screen keyboard
Press Save after making all the changes.
User Manual for LPU-1000 LED Player Unit - 106 - 01 Aug 2018
5. ADMIN PANEL
5 ADMIN PANEL
5.1 General Introduction
Set Up and Configuration
The Admin panel is an easy-to-use and convenient software tool for the maintenance and configuration of GDC
IMB. This Admin panel provides all the necessary tools for setting up and managing the IMB. A comprehensive array of easy to access menu pages are provided to simplify configuration and maintenance via a combination of simple buttons and an on-screen keyboard.
Secured Access
Clearly indicated button pages allow IMB network setup, maintenance and configuration, and access to software information. All actions can be performed by touching the drawn control on the screen of the IMB. Access to the Admin panel of the GDC IMB is available via the maintenance option and by entering a required password available from authorized GDC personnel only.
5.2 User Interface (UI)
5.2.1 Introduction
The Admin Panel UI provides access to the menu buttons and on-screen keyboard that are used for setting up and configuring the IMB. Diagnostic maintenance and/or monitoring of the status and performance of the IMB, other information including hardware of the IMB and configuration of the time zone and selection of the touchscreen type of the IMB can also be accessed through the Admin Panel UI
User Manual for LPU-1000 LED Player Unit - 107 - 01 Aug 2018
5. ADMIN PANEL
5.2.2 Access to Admin Panel
5.2.2.1 Access via Control Panel
Figure 80: LPU-1000 Control Panel
1 Press Control Panel on the SMS interface.
2 Click on the Admin panel button to go to the startup window for Admin Panel
2
User Manual for LPU-1000 LED Player Unit - 108 - 01 Aug 2018
5. ADMIN PANEL
5.2.2.2 Login to Admin Panel
2
3
4
Figure 81: Entering the password for Admin Panel SMS interface
1
2
User Manual for LPU-1000 LED Player Unit
Click on Focus . Clicking on Focus once before you start typing enables what you type in the onscreen keyboard to go into a specific window. Without focusing on the particular window, text will not appear even if you type something. Click Focus again only when necessary.
Click on the password entry on the screen and type in the required password using the on-screen keyboard and then press Login to access the Admin Panel SMS interface.
NOTE: The password is available from GDC authorized personnel only.
- 109 - 01 Aug 2018
1
5. ADMIN PANEL
3
Select Quit if you wish to go back to Control Panel . A small window pops out to confirm the selection.
Press Yes to confirm.
4
Select Shut Down if you wish to shut down the IMB. A small window pops up to confirm the selection.
Press Yes to confirm.
1
3
1
4
1
5.2.2.3 Admin Panel Interface
2
5
6
User Manual for LPU-1000 LED Player Unit
Figure 82: Admin Panel
- 110 -
8
01 Aug 2018
5. ADMIN PANEL
1
2
3
4
5
6
7
8
Storage System Management For creating a new RAID array and monitoring the RAID array status. Also shows hard disk information, hard disk usage, storage performance and increase rebuild speed.
Diagnostics/Maintenance
System Info
For changing time zone and extracting logs and configuration backups from the IMB.
Shows OS version, licensing, hardware and hotfix information.
Touchscreen
User Manager
For selecting touchscreen type and calibrating the touchscreen.
For adding/editing/deleting username, and for changing current user password.
DCI Compliance
For accessing the RTC clock to make time adjustments as well as extracting the Security Manager logs from the IMB.
Quit/Shutdown
On-screen keyboard
For switching to LPU-1000 SMS interface, for shutting down the IMB and restart all services.
For keying in text when not using an external keyboard.
User Manual for LPU-1000 LED Player Unit - 111 - 01 Aug 2018
5. ADMIN PANEL
5.3 Configuration & Maintenance
5.3.1 Storage System Management
1
Figure 83: Storage System Management
1 Select Storage System Management . A small window for Storage System Management pops up.
User Manual for LPU-1000 LED Player Unit - 112 - 01 Aug 2018
5. ADMIN PANEL
1
1
5.3.1.1 Create new RAID array
Figure 84: Storage System Management [Create new RAID array]
Select Create new RAID array
. A new window appears as seen in Figure 85.
2
User Manual for LPU-1000 LED Player Unit
Figure 85: Confirming to destroy data on the drive
- 113 -
3
01 Aug 2018
5. ADMIN PANEL
4
2
3
Select Yes or No to confirm or cancel the selection by clicking the right [ ➔ ] or left [ ] arrow keys on the on-screen keyboard and then click Return .
If less than three (3) hard disks are inserted to the PSD, a small dialog box will pop up:
Click Return on the on-screen keyboard to exit and return to Storage System Management.
Figure 86: RAID creation progress
4 The RAID creation progress is shown on the screen.
5 After the RAID is created, the following dialog box is shown.
Use SMS ➔ Configuration ➔ IMB Storage to mount the RAID.
User Manual for LPU-1000 LED Player Unit - 114 - 01 Aug 2018
5. ADMIN PANEL
5.3.1.2 Monitor RAID Status
1
1
Figure 87: Storage System Management [Monitor RAID status]
Select Monitor RAID Status . When the RAID is rebuilding, it displays the rebuilding progress as normal function to the previous RAID setup. A new window appears as seen in
2
2
Figure 88: Status of active RAID in the IMB
Press <CTRL + c> to quit and return to the Storage System Management.
User Manual for LPU-1000 LED Player Unit - 115 - 01 Aug 2018
5. ADMIN PANEL
5.3.1.3 Hard Disk Information
1
Figure 89: Storage System Management [Hard Disk Information]
1 Select Hard Disk Information
. A new window appears as seen in Figure 90.
2
Figure 90: Selecting the hard disk to be viewed
2 Select the disk you want to view the information from and press Select .
3
A new window will show the information for the selected disk as seen in Figure 91 .
Press Save output to USB to save a screenshot of the information to a USB disk.
Click Back to return to Storage System Management.
User Manual for LPU-1000 LED Player Unit - 116 - 01 Aug 2018
3
5. ADMIN PANEL
Figure 91: List of information for selected hard disk
User Manual for LPU-1000 LED Player Unit - 117 - 01 Aug 2018
2
5. ADMIN PANEL
5.3.1.4 Hard Disk Usage
Figure 92: Storage System Management [Hard Disk Usage]
1
2
Select Hard Disk Usage from Storage System Management .
A new window showing hard disk usage appears as seen in Figure 93 . Click
Back to return to the Storage System Management .
1
Figure 93: Size of the hard disk, and the used and available spaces in the hard disk
User Manual for LPU-1000 LED Player Unit - 118 - 01 Aug 2018
2
5. ADMIN PANEL
5.3.1.5 Storage Performance
Figure 94: Storage System Management [Storage performance]
1
2
Select Storage performance . A new window showing a list of hard disks appears as shown in
Select the hard disk you want to view and press Select to execute the process.
1
Figure 95: Storage performance [Select a Hard Disk]
User Manual for LPU-1000 LED Player Unit - 119 - 01 Aug 2018
5. ADMIN PANEL
Figure 96: Shows information on storage performance of the selected hard disk
3
A new window showing information on hard disk performance appears as seen in Figure 96 .
Press Save output to USB to save this information to a USB disk or Press Back to return to
Storage System Management .
User Manual for LPU-1000 LED Player Unit - 120 -
3
01 Aug 2018
5. ADMIN PANEL
5.3.1.6 Increase Rebuild Speed
1
Figure 97: Storage System Management [Increase Rebuild Speed]
1 If the RAID array is being rebuilt during playback, the rebuild speed will slow down significantly. To resume highest rebuild speed after playback is finished, go to Admin Panel ➔ Login ➔ Click
Storage System Management ➔ Click Increase Rebuild Speed button (please refer to
This will immediately set RAID array to rebuild at highest speed.
User Manual for LPU-1000 LED Player Unit - 121 - 01 Aug 2018
5. ADMIN PANEL
5.3.2 Diagnostics/Maintenance
5.3.2.1 Access to Diagnostics/Maintenance
Figure 98: Diagnostics/Maintenance
1 On the Main menu, select Diagnostics/Maintenance . A small window for Diagnostics/
Maintenance appears.
1
User Manual for LPU-1000 LED Player Unit - 122 - 01 Aug 2018
5. ADMIN PANEL
5.3.2.2 Extract Logs & Configuration
1
1
Figure 99: Diagnostics/Maintenance [Extract logs & configuration]
Select Extract logs . Select the set of logs required on this dialog box. A pop-up window will be shown indicating that the log extraction is in progress.
2 Once extract log files finished, a new window showing backup done is appeared. The USB can be removed.
User Manual for LPU-1000 LED Player Unit - 123 - 01 Aug 2018
5. ADMIN PANEL
5.3.2.3 Backup Configuration
1
Figure 100: Diagnostics/Maintenance [Backup configuration]
1
The Backup Configuration saves the IMB configuration to a backup file on a USB disk or thumb drive. Attach a USB thumb drive to the IMB and select Backup Configuration to save the current
IMB configuration.
2
Figure 101: Saving IMB configuration
User Manual for LPU-1000 LED Player Unit - 124 - 01 Aug 2018
5. ADMIN PANEL
2
The backup file is saved in an encrypted format as seen in Figure 101 . The following
configuration files are included in the backup file:
• Automation configuration
• SNMP configuration
• SMS configuration
• Content manager source configuration
• Network Time Protocol (NTP) configuration
• System user interface passwords
• Show Playlists
5.3.2.4 Restore Configuration
2
User Manual for LPU-1000 LED Player Unit
Figure 102: Diagnostics/Maintenance [Restore configuration]
Figure 103: Select file to restore
- 125 -
1
01 Aug 2018
5. ADMIN PANEL
1
2
Restore Configuration will restore the IMB configuration from a backup file on a USB disk or thumb drive.
When Restore Configuration is pressed, a list of backup files present on the USB disk is displayed.
Select the backup file to restore and then press Select .
3
Figure 104: Confirm restore
3
4
Information on the backup file will be displayed. Press Restore to confirm and restore configuration from the backup file.
When the configuration is restored from the backup file, a confirmation message will appear.
Press OK . IMB will then be rebooted.
- 126 - User Manual for LPU-1000 LED Player Unit 01 Aug 2018
5. ADMIN PANEL
5.3.2.5 Configure Timezone
1
Figure 105: Diagnostics/Maintenance [Configure Timezone]
1
2
Select Configure Timezone
. A new window will appear as seen in Figure 106.
Move the highlight bar to your geographical area by clicking the up [ ] or down [ ] arrow keys on the on-screen keyboard and then click the space key. Then click the right [ ➔ ] arrow key to select the OK button.
User Manual for LPU-1000 LED Player Unit
2
Figure 106: Selecting the timezone of specific region
- 127 - 01 Aug 2018
5. ADMIN PANEL
3
Figure 107: Selecting the timezone of specific country
3 Move the highlight bar to your timezone by clicking the up [ ] or down [ ] arrow keys on the onscreen keyboard and then click the space key. Then click the right [ ➔ ] arrow key to select the
OK button and click Return .
User Manual for LPU-1000 LED Player Unit - 128 - 01 Aug 2018
5. ADMIN PANEL
5.3.2.6 Check Network Access
1
1
2
Figure 108: Network [Check network access]
Select Check network access on the Network .
A new window appears to enter Network or IP address. Enter the Network or IP address, and then select Test connectivity .
2
3
Figure 109: Entering the IP address of the IMB
A new window will appear as seen in Figure 110 showing a list of information after testing the
connectivity.
User Manual for LPU-1000 LED Player Unit - 129 - 01 Aug 2018
5. ADMIN PANEL
3
4
Figure 110: Information shown after testing the connectivity of the IMB to the network
4
5
Press Save output to USB to save a screen capture of the information to a USB disk.
Press Back .
5
User Manual for LPU-1000 LED Player Unit - 130 - 01 Aug 2018
5. ADMIN PANEL
5.3.2.7 Network Time
Figure 111: Network [Network Time]
1 Select Network Time on the Network.
2
A new window appears for NTP service configuration as shown in Figure 112.
Select Enable NTP service . Type in the specified time server ’s IP address and press OK to start using the NTP server.
1
User Manual for LPU-1000 LED Player Unit
Figure 112: Entering the IP address of the time server
- 131 - 01 Aug 2018
5. ADMIN PANEL
5.3.2.8 Software Upgrade
1
Figure 113: Diagnostics/Maintenance [Software Upgrade]
1 From the Software Upgrade button in the Admin Panel you can run any GDC issued upgrade files,
once you press the button you will be prompted for the upgrade password as seen in Figure 114 .
2
2
Figure 114: Diagnostics/Maintenance [Software Upgrade]
Enter the password of the upgrade file and press Enter.
User Manual for LPU-1000 LED Player Unit - 132 - 01 Aug 2018
5. ADMIN PANEL
3
3
Figure 115: Diagnostics/Maintenance [Software Upgrade]
Select the upgrade file from the dropdown list and press OK .
User Manual for LPU-1000 LED Player Unit - 133 - 01 Aug 2018
5. ADMIN PANEL
5.3.2.9 Check IP Conflict
1
Figure 116: Diagnostics/Maintenance [Check IP Conflict]
1 Select Check IP Conflict on the Network.
A new window will appear as shown in Figure 117.
2
Figure 117: Network interface Selection
2 Select a network interface for checking IP conflict.
User Manual for LPU-1000 LED Player Unit - 134 - 01 Aug 2018
5. ADMIN PANEL
3
3
Figure 118: IP Conflict result
Select Save output to USB to save a screenshot of the information to a USB disk.
Click Back to exit.
User Manual for LPU-1000 LED Player Unit - 135 - 01 Aug 2018
5. ADMIN PANEL
1
5.3.3 System Information
5.3.3.1 Access to System Info
Figure 119: System Info
1 On the Main menu, select System Info . A small window for System info appears.
User Manual for LPU-1000 LED Player Unit - 136 - 01 Aug 2018
5. ADMIN PANEL
5.3.3.2 Software/OS Version
2
1
2
1
Figure 120: System Info [Software/OS version]
Select Software/OS version on System Info.
The OS and Software versions of the IMB are shown in a new window as seen in
Press Back to return to System Info.
Figure 121: Shows current software and OS versions of the IMB
User Manual for LPU-1000 LED Player Unit - 137 - 01 Aug 2018
5. ADMIN PANEL
2
1
5.3.3.3 Hardware Information
Figure 122: System Info [Hardware information]
1
2
Select Hardware information on the System Info.
A new window showing the list of hardware information including the Motherboard, Video card
and JPEG2000 card used in the IMB as seen in Figure 123 . Press
Back to exit and return to
System Info.
Figure 123: List of hardware information including the Motherboard, Video card and JPEG2000 card used in the IMB
User Manual for LPU-1000 LED Player Unit - 138 - 01 Aug 2018
5. ADMIN PANEL
5.3.3.4 Licensing Information
Figure 124: System Info [Licensing information]
1
1
2
Select Licensing information on System Info.
A new window shows the serial number and license capabilities of available options in the
server as seen in Figure 124 . Press
Back to return to System Info.
2
Figure 125: The serial number and license capabilities of available options in the server
User Manual for LPU-1000 LED Player Unit - 139 - 01 Aug 2018
5. ADMIN PANEL
5.3.3.5 Hotfix Information
Figure 126: System Info [Hotfix information]
1
1
2
Select Hotfix information . It allows the user to check on the patches and upgrades installed on the IMB.
A new window showing hotfix information appears as seen in Figure 127 . Press
Back to return to the System Info.
2
User Manual for LPU-1000 LED Player Unit
Figure 127: Patches and upgrades installed in the IMB
- 140 - 01 Aug 2018
5. ADMIN PANEL
5.3.3.6 Module Information
1
Figure 128: System info [Module information]
1 The Module information button provides the user with detailed version information used in troubleshooting.
2
A new window showing module version information appears as seen in Figure 129.
Back to return to the
System Info .
User Manual for LPU-1000 LED Player Unit
Figure 129: Module Version Information
- 141 - 01 Aug 2018
5. ADMIN PANEL
5.3.4 Touchscreen
5.3.4.1 Access to Touchscreen
1
Figure 130: Touchscreen
1 On the Main menu, select Touchscreen.
Touchscreen appears showing two types of touchscreens.
User Manual for LPU-1000 LED Player Unit - 142 - 01 Aug 2018
5. ADMIN PANEL
5.3.4.2 Select Touchscreen Type
1
2
Figure 131: Touchscreen [Switch Touchscreen Type]
1
2
Select Switch Touchscreen Type . A small dialog box pops up warning that the cursor may stop working if a change is made to the touchscreen type.
Select Yes to confirm the change in touchscreen type.
A small menu for selecting the touchscreen type appears:
(a) (b)
(a) If TK USB is selected, the screen will switch to TK screen in USB connection with the system.
Press OK to confirm.
(b) If NONE is selected, touchscreen functionality will be disabled. Press OK to confirm.
User Manual for LPU-1000 LED Player Unit - 143 - 01 Aug 2018
5. ADMIN PANEL
(c) A small window indicating no change in touchscreen type will appear if the selected screen type is already activated.
5.3.4.3 Calibrate Touchscreen
1
2
1
2
Figure 132: Touchscreen [Calibrate Touchscreen]
Select Calibrate Touchscreen .
If Calibrate Touchscreen is selected when in TK USB screen , the screen will appear as seen in
3
2
Figure 133: Calibrating the touchscreen by 4-pt calibration method
3 Touch the blinking symbol until it stops. Continue touching the blinking symbols on each of the four (4) corners of the screen to complete the calibration of the touchscreen.
User Manual for LPU-1000 LED Player Unit - 144 -
2
2
01 Aug 2018
5. ADMIN PANEL
5.4 User Manager
5.4.1 Access to User Manager
1
Figure 134: User Manager
On the Main menu, select User Manager . A small window for User Manager appears.
5.4.2 Add/Edit user
1
1
Figure 135: User manager [Add/Edit user]
On the Main menu, select Add/Edit user . A new window for username and password
entries will appear as shown in Figure 136.
User Manual for LPU-1000 LED Player Unit - 145 -
1
01 Aug 2018
5. ADMIN PANEL
Figure 136: Username and Password entries
2
3
Type in your desired Username and Password using the on-screen keyboard to create a new username & password and press OK .
A small window will appear after creating your username and password.
Press OK to confirm and exit.
2
User Manual for LPU-1000 LED Player Unit - 146 - 01 Aug 2018
5. ADMIN PANEL
4 To edit the password, enter your current username and type in your new password.
A small window pops up asking if you want to change the password. Press Yes to confirm.
A new window appears to confirm the password has changed. Press OK to exit and
return to User Manager .
5.4.3 Delete User
1
1 Select Delete user
. A new window appears showing a list of usernames as seen in Figure 137 .
User Manual for LPU-1000 LED Player Unit - 147 - 01 Aug 2018
5. ADMIN PANEL
2
Figure 137: Selecting the username to be deleted
2 Select the username you want to delete and press Select . A small window pops up to confirm if you want to continue to delete the user.
Select Yes to confirm. A small window appears confirming the user has been deleted.
Press OK to exit and return to User Manager.
User Manual for LPU-1000 LED Player Unit - 148 - 01 Aug 2018
5. ADMIN PANEL
5.4.4 Change Current User Password
Figure 138: User manager [Change current user password]
1
1 Select Change current user password . A new window for password entry appears as seen in
Figure 139: Password entry to change password
1 Type in your new password and press OK . A small window appears confirming the change in password.
Press OK to exit and return to User Manager.
2
User Manual for LPU-1000 LED Player Unit - 149 - 01 Aug 2018
5. ADMIN PANEL
5.5 DCI Compliance
5.5.1 Access to DCI Compliance
1
1
Figure 140: DCI compliance
Press the DCI compliance button to access the RTC time offset or extract the SM (Security Manager) logs.
User Manual for LPU-1000 LED Player Unit - 150 - 01 Aug 2018
5. ADMIN PANEL
5.5.2 Offset RTC Time
1
2
Figure 141: RTC Offset
1 The allowed offset range is set to plus or minus 360 seconds
2
The Offset can be set + or – within the allowed offset range seen in field 1. The time is set in MM: SS
(Minutes: Seconds)
User Manual for LPU-1000 LED Player Unit - 151 - 01 Aug 2018
5. ADMIN PANEL
5.5.3 Get SM Log
1
1
Figure 142: Set time for SM log
Choose the date and time range for SM log extraction. It is possible to alter the name of the output file with the Key Pad button. Once a USB drive has been inserted press the Get Log button.
User Manual for LPU-1000 LED Player Unit - 152 - 01 Aug 2018
5. ADMIN PANEL
5.6 Quit/Shutdown
Figure 143: Quit/Shutdown
1 On Main menu, select Quit/ Shutdown . A small window shows the Quit/Shutdown.
(a)
(c)
(a) Select Quit to switch to the Control Panel.
(b)
(d)
(b) Select Shut Down to turn off the IMB.
(c) Select Logout to logout the current user and return to the Admin Panel startup window.
1
User Manual for LPU-1000 LED Player Unit - 153 - 01 Aug 2018
7. APPENDIX
(d) Select Restart all services to restart all automation, communications, playback, and content management services on the IMB. Playback will be stopped while services are restarted.
Select Yes to restart services or No to cancel.
A confirmation message will be displayed after all services are restarted.
Press OK to exit.
User Manual for LPU-1000 LED Player Unit - 154 - 01 Aug 2018
6. OPERATION NOTES
6 OPERATION NOTES
6.1 Power On Sequence
Always follow the sequences below to power ON the system.
1. First, power on the external storage.
2. Power on the LPU-1000 LED Player Unit.
Important Note : Always power on any external storage before powering on the LPU-1000 LED Player Unit. The external storage must be powered on first to be correctly identified by the LPU-1000.
6.2 Power Off Sequence
Always follow the sequences below to power OFF the system.
1. Power off the media block by using the SMS -> Shutdown button.
2. Power off the LPU-1000 after the media block is off.
3. Power off any external storage attached to the LPU-1000.
User Manual for LPU-1000 LED Player Unit - 155 - 01 Aug 2018
7. APPENDIX
7 Appendix
This section describes optional features on the LPU-1000 that require licenses from GDC.
7.1 Network Streaming
The LPU-1000 is capable of playing live network streams. This section provides information on configuring the
LPU-1000 for live network streaming.
7.1.1 System Configuration
Use the ‘Streaming’ tab on the SMS configuration interface to set network streaming parameters.
1
3
2
Figure 144: Streaming Tab
- 156 - User Manual for LPU-1000 LED Player Unit 01 Aug 2018
7. APPENDIX
1
2
This configuration option allows video and audio to be buffered for a fixed amount of time before playback. (Recommended value: 5 seconds). Increasing this value is only needed on unstable connections.
This configuration option allows audio to be delayed, for cases where source audio and video are out of sync. Both positive and negative audio and video playback. (Recommended value: 0 frames).
3
Setting the ‘PTS sync’ option will force playback to use the Presentation TimeStamp (PTS) header in the IP Stream to synchronize audio and video playback. (Recommended: unchecked)
Note : Using this option will use a new mechanism to sync audio and video playback. ‘Unchecked’ is the same method as used in prior software versions and is recommended. Check this option only if default unchecked method fails to achieve proper audio and video sync
7.1.2 Network Streaming Configuration
1
2
User Manual for LPU-1000 LED Player Unit
Figure 145: Streaming Tab
- 157 - 01 Aug 2018
7. APPENDIX
1
2
[UDP Multicast]
[Multicast Group address]
[Multicast port]
[Video PID]
[Audio PID]
[Subtitle PID]
[Video Type]
[3D Demux]
[Audio Type]
[AC3 output on channels]
[PTS Sync]
This section will configure the network stream parameters.
IP Address of streaming source
Port of the streaming source related to the IP address
Video, Audio and Subtitle PID are usually provided by the broadcaster. If the video or audio
PID is set to ‘0’, the LPU-1000 will automatically search and play back the last video or audio stream found in the network system.
Check Force PID box to ensure the LPU-1000 to use the provided PIDs. Note: having the values set to
‘0’ will cause errors in receiving the network stream when the Force PID box is checked.
Choose between MPEG2 and H.264 (MPEG4) or Auto-Detect.
Select whether to apply 3D demux to incoming video stream. None (2d): 2D video output;
Side-by-side (3D): 3D video output with side-by-side 3D demux
Audio Type can be automatically detected, or you may choose either AC3 or MPEG2, depending on the exact audio format delivered by streaming content
AC3 audio output from LPU-1000 will pass-through as a digitally compressed audio system to an external audio processor. Select a pair of LPU-1000 audio output channels to send this pass-through compressed audio system
Setting the “PTS sync” configuration option will force playback to use the Presentation
TimeStamp (PTS) header in the IP stream to synchronize audio and video playback.
(Recommended: unchecked)
Note: Selecting this option will use a new mechanism to sync audio and video playback.
Check this option only if the default, unchecked option fails to achieve proper audio and video sync.
User Manual for LPU-1000 LED Player Unit - 158 - 01 Aug 2018
7.APPENDIX
7.2 MDA Decoding
This section provides information on configuring the LPU-1000 for MDA internal decoding.
7.2.1 Requirement
The following items are required for MDA internal decoding on LPU-1000
•
LPU-1000 LED Player Unit
•
MDA Playback (Internal Decoder) LDM for the server's serial number
•
MDA configuration file for the cinema the server is to be installed in
7.2.2 Server configuration for MDA playback
7.2.2.1 Setting up the server for MDA playback
1. Use the Content Manager to ingest the 'MDA Playback (Internal Decoder)' LDM to the server.
2. Change the setting for SMS -> Configuration -> Audio -> MDA decoding to 'Internal'.
USER MANUAL FOR LPU-1000 LED PLAYER UNIT
Figure 146: MDA Decoding Setup
- 159 - 26 Feb 2018
7. APPENDIX
7.2.2.2 Setting up the MDA configuration file
Note: A valid MDA configuration file must be set before playback with MDA internal decoding.
Take note of the server IP address, and load the MDA configuration webpage on a PC connected to the server.
For example, if the server IP address is '192.168.0.139', load the webpage
http://192.168.0.139/cgibin/mdaConfig
.
The MDA configuration web page will be shown as follows:
Figure 147: MDA Configuration Manager
Use the ' Upload MDA configuration ' section to upload MDA configuration files from the PC to the LPU-
1000 LED Player Unit.
Note: MDA configuration files must be named in the format 'mda-<XXX>.cfg'.
The ' Select MDA configuration ' section can be used to select the active MDA configuration from uploaded configuration files. In the example below, the sample 'mda-51.cfg' configuration has been set to be used for playback.
User Manual for LPU-1000 LED Player Unit - 160 - 01 Aug 2018
7. APPENDIX
USER MANUAL FOR LPU-1000 LED PLAYER UNIT
Figure 148: MDA Configuration Manager
- 161 - 5 Mar 2018
7. APPENDIX
7.2.3 Audio channel routing requirements
In order to allow for audio playback of content with 5.1 channel audio, 7.1 channel audio and MDA audio without speaker re-configuration, audio channel routing configuration needs to be done.
After selecting Internal for MDA decoding, it is possible to select either Route HI/VI-N, Route D-Box or No
Routing.
Route HI/VI-N
Route D-Box
Route channels 7/8 to 15/16
Route channels 13/14 to 15/16
User Manual for LPU-1000 LED Player Unit
Figure 149: MDA Decoding
- 162 - 01 Aug 2018
7. APPENDIX
7.3 Audio Upmix
This section provides information on configuring the LPU-1000 for audio upmix.
7.3.1 Requirement
•
License for MDA playback (internal rendering)
7.3.2 Setup
7.3.2.1 Enable audio upmix
1. Audio upmix is enabled in SMS -> Configuration -> Audio tab -> Audio Channel Mapping -> Upmix.
2. Check the 'Enable Upmix' checkbox to enable audio upmix.
3. Enter a valid IP address for the Sound Processor IP field.
Figure 150: Upmixing
NOTE : All other audio channel routing options are disabled when Audio Upmix is enabled
User Manual for LPU-1000 LED Player Unit - 163 - 01 Aug 2018
7. APPENDIX
7.3.2.2 Set CPL audio track properties
1. This feature allows the user to define audio track properties for each CPL in an SPL.
2. This can be done from SMS Playlist Management -> CPL Properties -> Audio tab.
Figure 151: CPL audio track properties setting
Audio track properties can be changed for each CPL if they are not detected correctly.
For example, if a CPL is known to contain 7.1 surround audio, change the 'Audio Channel Configuration' setting to '7.1 surround'.
USER MANUAL FOR LPU-1000 LED PLAYER UNIT - 164 - 5 Mar 2018
7. APPENDIX
Figure 152: CPL audio track properties setting
The audio channel configurations available for each CPL are as follows:
Audio channel configuration
Unspecified
2.0 stereo
5.1 surround
7.1 surround
Audio upmix applied
No audio upmix applied
No audio upmix applied
Upmixed from 5.1 surround to 13.1
Upmixed from 7.1 surround to 13.1
USER MANUAL FOR LPU-1000 LED PLAYER UNIT - 165 - 5 Mar 2018
GDC Technology Offices
Hong Kong (Headquarters)
Unit 1-7, 20th Floor,
Kodak House II,
39 Healthy Street East,
North Point,Hong Kong.
Tel: +852 2507 9555
China (Beijing)
Rm. 609-618, Office Building,
20# Xinde Street,
Xicheng District,
Beijing, P.R. China 100088
Tel: +86 10 6205 7040
China (Shenzhen)
Room A701, 7/F,
Languang Technology Building,
No.7 Xinxi Road,
North Zone,
High-Tech Park,
Nanshan District,
Shenzhen, China
Tel: +86 755 8608 6000
Spain (Barcelona)
C/ Esteve Terradas, nº 27, esc. D, Despacho 1,
08023 Barcelona, Spain
Tel: +34 93 159 51 75
Peru (Lima)
Calle Manuel Miota 170
Miraflores Lima 18, Perú
Tel: +51 1 340 5146
USA (Los Angeles)
1016 West Magnolia Boulevard
Burbank, CA 91506, USA
Tel: +1 818 972 4370 /
+1 877 743 2872 (Toll Free)
Email: [email protected]
Website: www.gdc-tech.com
ISO 9001 QMS
Cert. No. CN09/32221
GDC Technology manufacturing facility is ISO 9001:2008 certified.
Copyright © 2018 GDC Technology Limited. All rights reserved.
All trademarks listed in this manual are properties of their respective owners.
Specifications are subject to change without notice due to ongoing product development and improvement.
UM-0732-1802-V1E
Brazil (São Paulo)
Av. Antônio Carlos Comitre, 540,
3º andar, Conjunto 31, Campolim,
Sorocaba / São Paulo, CEP 18047-620, Brasil
Tel: +55 15 33269301
Singapore
10 Ubi Crescent, Ubi Tech Park
Lobby B, #06-25, Singapore 408564
Tel: +65 6222 1082
Indonesia (Jakarta)
Total Building Lantai 4 Suite 0401,
Jl. Letjen S. Parman Kav. 106A,
Kel. Tomang, Kec. Grogol Petamburan,
Jakarta Barat 11440, Indonesia
Tel: +65 21 2920 3607
Japan (Tokyo)
3F, Kyobashi-Chuo Bldg,
1-14-7 Kyobashi Chuo-ku,
Tokyo 104-0031, Japan
Tel: +81 3 5524 3607
India (Mumbai)
Office No. B-207/208, Everest Chamber,
Andheri Kurla Road, Marol, Andheri (East),
Mumbai-400 059, India
Tel: +91 22 4044 0500
Mexico (Mexico City)
Av. Del peñon 411 esq. Ote 168
Col. Moctezuma 2ª Sección,
Venustiano Carranza, Distrito Federal,
C.P. 01210 Mexico
Tel: +52 55 8526 6220
United Arab Emirates (Dubai)
Business Centre,
Dubai World Central,
PO Box 390667,
Dubai UAE
ダウンロード
広告