GHM GREISINGER G 1910-02 Quick Reference Manual

Add to My manuals
24 Pages

advertisement

GHM GREISINGER G 1910-02 Quick Reference Manual | Manualzz

EN

Quick reference guide

G 1910 series

Compact CO2 monitor with alarm

Table of contents

Table of contents

1

1.1

1.2

1.3

2

2.1

2.2

2.3

2.4

3

3.1

3.2

3.3

3.4

4

About this documentation ...................................................... 4

Purpose of the document ................................................................ 4

Legal notices .................................................................................. 4

Further information ......................................................................... 4

Safety ....................................................................................... 5

Explanation of safety symbols ........................................................ 5

Foreseeable misuse ....................................................................... 5

Safety instructions .......................................................................... 8

Intended use ................................................................................... 8

The product at a glance .......................................................... 9

The G 1910 series .......................................................................... 9

Display elements ............................................................................ 9

Operating elements ........................................................................ 9

Connections ................................................................................. 10

Measurement Basics ............................................................. 10

5

5.1

Operation and maintenance ................................................. 11

Operating and maintenance notices.............................................. 11

5.2 Battery .......................................................................................... 11

5.2.1 Charge status display ................................................................... 11

5.2.2 Charging the batteries .................................................................. 11

5.2.3 Rechargeable battery replacement ............................................... 11

5.3 CO

2

calibration ............................................................................. 12

6

6.1

6.2

Operation ............................................................................... 15

Opening the configuration menu ................................................... 15

Call-up of the expanded settings menu ......................................... 17

7

8

Error and system messages ................................................. 18

Technical data ....................................................................... 20

2 / 24 B-H90.0.0X.DK2-2.1

9

9.1

Table of contents

Service ................................................................................... 24

Manufacturer ................................................................................ 24

B-H90.0.0X.DK2-2.1 3 / 24

1 | About this documentation G 1910 series

1

_

1.1

About this documentation

Purpose of the document

This document is intended as a quick reference option.

It does not replace the operating manual.

For this reason, read the operating manual before operating the product for the first time.

1.2 Legal notices

This document is entrusted to the recipient for personal use only. Any impermissible transfer, duplication, translation into other languages or excerpts from this operating manual are prohibited.

The manufacturer assumes no liability for print errors.

_

1.3 Further information

Software version of the product:

V1.6 or later

_

_

Link to the complete operating manual: http://www.greisinger.de

For the exact product name, refer to the type plate on the rear side of the product.

4 / 24 B-H90.0.0X.DK2-2.1

G 1910 series Safety | 2

2 Safety

_

2.1 Explanation of safety symbols

DANGER

This symbol warns of imminent danger, which can result in death, severe bodily injury,

_ or severe property damage in case of non-observance.

CAUTION

This symbol warns of potential dangers or harmful situations, which can cause damage

_ to the device or to the environment in case of non-observance.

NOTE

This symbol indicates processes, which can have a direct influence on operation or can trigger an unforeseen reaction in case of non-observance.

_

2.2 Foreseeable misuse

The fault-free function and operational safety of the product can only be guaranteed if applicable safety precautions and the device-specific safety instructions for this document are observed.

If these notices are disregarded, personal injury or death, as well as property damage can occur.

B-H90.0.0X.DK2-2.1 5 / 24

2 | Safety G 1910 series

_

DANGER

Incorrect area of application!

_

In order to prevent erratic behaviour of the product, personal injury and property damage, the product must be used exclusively as described in the chapter Description in the operating manual.

– The product is not suitable for use in explosion-prone areas!

– The product must not be used for diagnostic or other medical purposes on patients!

– The product is not intended to come into direct contact with food!

– For measurements requiring devices that are subject to authorisation or special approvals, this product is not a substitute for such products and can only be used as an aid in preparatory or comparison measurements!

DANGER

Danger due to elevated CO

2

concentration

The product is not suitable for use as personal protective equipment with elevated CO

2 levels. However, it can indicate an elevated CO

2

value. The measured value appears in the display as a % or ppm value.

6 / 24 B-H90.0.0X.DK2-2.1

G 1910 series Safety | 2

G 1910-

02

G 1910-

20

CO

2

concentration

%

20 ppm

Effect

Death within a few seconds

10

4.0

3.0

Loss of consciousness, death, dizziness, vomiting, headaches, reduced blood flow to brain

IDLH - immediate danger to life and health

Normal exhalation concentration, elevated breathing and pulse rate

2,0 20,000

Possible shortness of breath 1.0 10,000

0.5 5000

0.1 .. 0.2 1000 ..

2000

0.04 400

TWA – Maximum for working conditions

Recommended maximum value in public areas

Fresh air

Product is not permitted for the area

Expanded measuring range. The product can be used conditionally

Area of application of the product with specified accuracy

The values are guideline values. Depending on the health condition and duration of exposure, problems can also occur below the indicated concentrations under certain circumstances.

B-H90.0.0X.DK2-2.1 7 / 24

2 | Safety G 1910 series

_

2.3 Safety instructions

NOTE

This product does not belong in children's hands!

_

2.4 Intended use

The product is designed exclusively for measurements in ambient air and environments with slightly elevated CO

2

concentrations in areas that are not harmful to the health. It is designed to be carried on the body for mobile use. The user can be warned optically and acoustically of elevated CO

2

concentrations based on variable alarm limits. Example applications for this are:

Use as a monitor for recording of the mean value weighted over 8 hours (TWA) or 15 minutes (STEL).

Monitoring of air quality.

8 / 24 B-H90.0.0X.DK2-2.1

3

3.1

G 1910 series

The product at a glance

The G 1910 series

Measurement Basics | 4

_

Sensor openings Micro USB socket

LCD Display

Front view

_

3.2

_

Display

Display elements

Charge status display Evaluation of the charge status

_

Unit display

Display of units or type of mode, min/max/hold

_

Main display

Measurement of the current CO

2

value

_

Auxiliary display

Display of the mean value

_

_

3.3

Bar graph Visualisation of the CO

2

value

Operating elements

On / Off button

Press briefly Switch on the product

Long press

B-H90.0.0X.DK2-2.1

Activate / deactivate lighting

Switch off the product

Reject changes in a menu

9 / 24

4 | Measurement Basics

Up / Down button

Press briefly

G 1910 series

Display of the min/max value

Long press

Change value of the selected parameter

Reset the min/max value of the current measurement

Rotate display, overhead display

_

Both simultaneously

Function key

Press briefly Freeze measurement (Hold)

3.4

Return to measurement display

Call up next parameter

Long press, 2s

Connections

Start menu configuration,

(ONF

appears in the display

Micro USB socket Charging the batteries

4 Measurement Basics

For additional information, refer to the operating manual!

10 / 24 B-H90.0.0X.DK2-2.1

G 1910 series Operation and maintenance | 5

5 Operation and maintenance

_

5.1 Operating and maintenance notices

CAUTION

Damage to the sensor

_

A sensitive optical sensor is installed in the product. The sensor parameters can change due to impact or falling. This can result in incorrect measurements.

– Protect the product from impact and falling!

– The measurements must be checked after the product falls or is jarred. If the values deviate, a basic sensor adjustment must be carried out!

NOTE

The product must be handled with care and used in accordance with the technical

_ data. Do not throw or strike.

NOTE

If the product is stored at a temperature above 50 °C, or is not used for an extended period of time, the batteries must be removed or recharged regularly. This prevents leaks from the rechargeable batteries and increases the life of the rechargeable batteries.

5.2 Battery

_

5.2.1 Charge status display

For additional information, refer to the operating manual!

_

5.2.2 Charging the batteries

For additional information, refer to the operating manual!

_

5.2.3 Rechargeable battery replacement

B-H90.0.0X.DK2-2.1 11 / 24

5 | Operation and maintenance G 1910 series

Only use new, high-quality and suitable

NiMH rechargeable batteries!

NiMH rechargeable batteries

For additional information, refer to the operating manual!

_

5.3 CO

2

calibration

For additional information refer to the operating manual!

In order to improve the accuracy, the carbon dioxide sensor can be calibrated. In order to conduct a CO

2

calibration, proceed as follows.

NOTE

Calibration can be carried out in clean ambient air or with test gases (optionally available gas extraction device recommended). 1-point calibration at any arbitrary point and

12 / 24 B-H90.0.0X.DK2-2.1

G 1910 series Operation and maintenance | 5

2-point calibration at 0 ppm and an arbitrary point are both possible. Refer to the operating manual for the 2-point calibration!

For automatic calibration, open the Calibration menu.

The product is switched on.

Clean ambient air or test gas for gradient correction

Gas extraction device, if applicable

1. Press the Function key for 4 seconds to start the calibration.

[ONF

appears in the display first, then

[AL

.

2. 1-point or 2-point calibration is started. This depends on what was adjusted in the

Expanded settings menu.

3.

[.SL

appears in the display for 1-point calibration.

4. The product determines a stable value first. If the measured value is outside of the value range integrated in the product, the display flashes briefly and an acoustic signal is issued every 10 s.

5. If the display flashes briefly, an acoustic signal sounds and the bar display blinks, a stable correct value has been achieved.

B-H90.0.0X.DK2-2.1 13 / 24

5 | Operation and maintenance G 1910 series

6. You can change the value of the gradient compensation with the up key and down key

. Otherwise, confirm the preadjusted value with the function key

. The 1-point calibration is finished.

NOTE

Current test gases normally have accuracies of ± 2 %. This tolerance must be taken into consideration with the measurement uncertainty. The specifications on the analysis certificate must always be observed.

NOTE

For information about the available calibration settings, refer to Configuring parameters of the configuration menu.

After the calibration is finished

[AL DONE

is displayed.

Then, the current measurement is shown in the display again.

If the calibration is not completed successfully an error message is displayed.

[AL ERR.

appears in the display. See

Error and system messages [  18]

. Confirm the error mes-

sage pressing the Function key . The product restarts. The values of the last correctly performed calibration are restored.

14 / 24 B-H90.0.0X.DK2-2.1

G 1910 series

6 Operation

6.1 Opening the configuration menu

_

1. Press the

Function key

for 2 seconds to open the

Configuration

menu.

2.

(ONF

appears in the display. Release the

Function key

.

Parameter Values Meaning

_

Input

INP

% CO

2

measurement in %

Operation | 6

PPm CO

2

measurement in ppm

_

Alarms

AL.

OFF

ON

No active alarm

BEEP

L,TE

Alarm alerting via text display, acoustic signal and flashing of the backlighting

Alarm alerting via text display and acoustic signal

Alarm alerting via text display and flashing of the backlighting

B-H90.0.0X.DK2-2.1 15 / 24

6 | Operation G 1910 series

_

AL.1

0

.

000

..

AL

.

2

0

..

AL2

_

AL.2

G 1910-02

G 1910-02

G 1910-20

AL.1

..

1

.

000

in % Max. alarm limit, the main alarm is triggered when the value is exceeded

AL.1

..

10000

in ppm

AL.1

..

19999

in ppm

Max. alarm limit, the main alarm is triggered when the value is exceeded

Max. alarm limit, the main alarm is triggered when the value is exceeded

AL.1

..

3

.

200

in % Max. alarm limit in %; the main alarm is triggered when the value is exceeded

G 1910-20

_

Mean value

LCD.2

Depending on the setting of the parameter value

INP

Min. alarm limit in % or ppm; a pre-alarm is triggered when the value is exceeded

When the pre-alarm is triggered, it can be muted for

5 minutes. To do this, press any key. The display shows

(LR AL.1

.

Depending on the setting of the parameter value

INP

8 H

STEL

OFF

Time weighted over 8 hours, mean value TWA

Time weighted over 15 minutes, mean value STEL

Mean value determination deactivated

16 / 24 B-H90.0.0X.DK2-2.1

G 1910 series Operation | 6

Shut-off time

POFF

OFF No automatic shut-off

0

:

15 0

:

30 1

:

00 4

:

00

12

:

00

Automatic shut-off after a selected time in hours and minutes, during which no buttons have been pressed

_

Backlight

L,TE

OFF Backlight deactivated

0

:

15 0

:

30 1

:

00 4

:

00

Automatic shut-off of the backlight after a selected time in minutes and seconds, during which no buttons have been pressed

_

Factory settings

ON

IN,T

No automatic shut off of the backlight

NO Use current configuration

YES

Reset product to factory settings.

IN,T DONE

appears in the display

6.2 Call-up of the expanded settings menu

For information refer to the operating manual!

B-H90.0.0X.DK2-2.1 17 / 24

7 | Error and system messages G 1910 series

7

Display

----

----

Error and system messages

Meaning Possible causes Remedy

No signal from the sensor

Measurement far outside of the measuring range

Sensor not ready Wait the start-up time of the sensor

CO

2

concentration too high Place the product in clean outdoor air

Defective sensor adjustment Perform sensor adjustment

Sensor defect Send in for repair

The display value could not be determined

Sensor not ready

Sensor defect

Wait the start-up time of the sensor

Send in for repair

No display, unclear characters or no response when buttons are pressed

Rechargeable battery depleted

System error

Rechargeable battery depleted

Error in the product

Charge battery

Replace rechargeable battery

Product is defective Product is defective Send in for repair

BAT LO Rechargeable battery depleted

Rechargeable battery discharged

Rechargeable battery defect

Charge battery

Replace rechargeable battery

(AL ERR.1

Incorrectly measured CO

2

concentration for adjustment

Expose sensor to a test gas with 0 ppm CO

2

Zero point adjustment defective

(AL ERR.2

(AL ERR.3

18 / 24

Defective gradient compensation

Incorrectly measured CO

2

concentration for adjustment

Expose sensor to a test gas with known CO

2

concentration

Enter correct value Incorrect CO

2

concentration

B-H90.0.0X.DK2-2.1

G 1910 series Error and system messages | 7

(AL ERR.5

ERR.1

ERR.2

ERR.7

ERR.T

STAB

SYS ERR

Time for stability recognition exceeded

Stability recognition lasts longer than 10 minutes

Provide a consistent flow with a constant CO

2

concentration

Measuring range exceeded

Measurement too high

Stay within allowable measurement range

Defective sensor adjustment

Perform sensor adjustment

Send in for repair

Sensor defect

Measuring range is undercut

Defective sensor adjustment

Perform sensor adjustment

Send in for repair

Sensor defect

Sensor error

Temperature error Permissible temperature range during charging exceeded or undercut

Charging of battery only at 0

.. 40 °C

Bring product to room temperature and restart charging process

System error

Defective sensor adjustment

Perform sensor adjustment

Send in for repair

Sensor defect

No measurement change within 2 minutes

Error in the product

Sensor defect

Switch product on/off

Replace rechargeable batteries

Send in for repair

Product in extremely Place the product in clean constant environment outdoor air

Perform sensor adjustment

Sensor defect

Send in for repair

B-H90.0.0X.DK2-2.1 19 / 24

8 | Technical data G 1910 series

_

_

8

G 1910-02

Technical data

Measuring range (specified accuracy)

0 .. 2000 ppm

Measuring range (not specified)

0.000 .. 0.200 %

0.000 .. 1.000 %

Accuracy

Measuring cycle

Display

Additional functions

Adjustment

Housing

± 70 ppm ± 3 % measurement

2 seconds

3-line segment LCD, additional symbols, illuminated (adjustable white, permanent illumination)

Min/Max/Hold

TWA calculation / STEL

2-stage alarm (optical and acoustic)

1-point, 2-point and basic sensor adjustment

Break-proof ABS housing

Protection rating IP30

Dimensions

L*W*H [mm] and weight

108 * 54 * 28 mm without measuring cell or kink protection

180 g, incl. battery and measuring cell

Operating conditions 0 to 50 °C; 0 to 85 % r.h. (non-condensing)

Storage temperature -20 to 70 °C

20 / 24 B-H90.0.0X.DK2-2.1

G 1910 series Technical data | 8

_

_

Current supply

2*AA-NiMH batteries (included in delivery)

Current requirement/

Rechargeable battery life approx. 50 mA, approx. 60 mA with lighting

Life approx. 24 hours with NiMH batteries (without backlight) charging time of about 8 hours

Battery indicator 4-stage charge status indicator,

Charge indicator for low charge level: "BAT LO"

Plug connector

Auto-power-OFF function

Micro USB socket (not a data connection)

The device switches off automatically if this is activated

Directives and standards The devices conform to the following Directives of the Council for the harmonisation of legal regulations of the Member States:

2014/30/EU EMC Directive

2011/65/EU RoHS

Applied harmonised standards:

EN 61326-1:2013 Emission limits: Class B

Immunity according to Table 2

Additional errors: < 1 % FS

EN 50581:2012

The device is intended for mobile use and/or stationary operation in the scope of the specified operating conditions without further limitations.

B-H90.0.0X.DK2-2.1 21 / 24

8 | Technical data G 1910 series

G 1910-20

Measuring range (specified accuracy)

0 .. 19999 ppm

Measuring range (not specified)

0.000 .. 2.000 %

0.000 .. 3.200 %

Accuracy

Measuring cycle

Display

Additional functions

Adjustment

Housing

± 0.02 % ± 3 % measurement

2 seconds

3-line segment LCD, additional symbols, illuminated (adjustable white, permanent illumination)

Min/Max/Hold

TWA calculation / STEL

2-stage alarm (optical and acoustic)

1-point, 2-point and basic sensor adjustment

Break-proof ABS housing

Protection rating IP30

Dimensions

L*W*H [mm] and weight

108 * 54 * 28 mm without measuring cell or kink protection

180 g, incl. battery and measuring cell

Operating conditions 0 to 50 °C; 0 to 85 % r.h. (non-condensing)

Storage temperature -20 to 70 °C

22 / 24 B-H90.0.0X.DK2-2.1

G 1910 series Technical data | 8

Current supply

2*AA-NiMH batteries (included in delivery)

Current requirement/

Rechargeable battery life approx. 50 mA, approx. 60 mA with lighting

Life approx. 24 hours with NiMH batteries (without backlight) charging time of about 8 hours

Battery indicator 4-stage charge status indicator,

Charge indicator for low charge level: "BAT LO"

Plug connector

Auto-power-OFF function

Micro USB socket (not a data connection)

The device switches off automatically if this is activated

Directives and standards The devices conform to the following Directives of the Council for the harmonisation of legal regulations of the Member States:

2014/30/EU EMC Directive

2011/65/EU RoHS

Applied harmonised standards:

EN 61326-1:2013 Emission limits: Class B

Immunity according to Table 2

Additional errors: < 1 % FS

EN 50581:2012

The device is intended for mobile use and/or stationary operation in the scope of the specified operating conditions without further limitations.

B-H90.0.0X.DK2-2.1 23 / 24

9 | Service G 1910 series

9

9.1

Service

Manufacturer

If you have any questions, please do not hesitate to contact us:

Contact

GHM Messtechnik GmbH

GHM GROUP - Greisinger

Hans-Sachs-Str. 26

93128 Regenstauf | GERMANY

Email: [email protected]

| www.greisinger.de

WEEE reg. no. DE 93889386

24 / 24 B-H90.0.0X.DK2-2.1