easy comp PM50 Instructions Manual
Add to My manuals12 Pages
Easy Comp PM50 is a portable compressed air source adequate to drive the high volume nebulizers. It has a maximum rated sustained pressure of 60 psi and a flow output of 15 lpm minimum at 50 psig. Easy Comp PM50 is equipped with a grounded 9/16 - 18 Male Threaded Fitting outlet and can be used with a variety of nebulizers and other medical devices that require compressed air. It also features a regulator knob for adjusting the pressure, a pressure gauge, and a built-in filter to remove impurities from the air.
advertisement
▼
Scroll to page 2
of
12
USER MANUAL Model: PM50 SA VE TH ESE I NS TRU CTIO NS C AU TIO N Federal (USA) law restricts this device to sale by or on the order of a physician. Your local distributor: 300 Held Drive Tel: (+001) 610-262-6090 866 -624 -3952 www.thinkMDI.net Northampton, PA 18067 USA Fax: (+001) 610-262-6080 www.precisionmedical.com Contents Receiving/inspection...................................................... 2 intended use..................................................................... 2 READ ALL INSTRUCTIONS BEFORE USING....................... 2 Explanation of Abbreviations ................................... 2 SAFETY Information - Warnings and Cautions...... 2 SPECIFICATIONS.................................................................. 4 COMPONENT IDENTIFICATION........................................... 5 GROUNDING INSTRUCTIONS.............................................. 6 OPERATING INSTRUCTIONS................................................ 6 Cleaning/maintenance.................................................. 7 returns............................................................................... 8 Disposal Instructions.................................................. 8 Replacement Parts......................................................... 8 limited warranty........................................................... 10 Receiving/inspection Remove the Precision Medical Easy Comp Compressor from packaging and inspect for damage. If there is any damage, DO NOT USE and contact your Equipment Provider. intended use The basic function is to supply a portable compressed air source adequate to drive the high volume nebulizers. READ ALL INSTRUCTIONS BEFORE USING This manual instructs a Professional to install and operate the Easy Comp Compressor. This is provided for your safety and to prevent damage to the Compressor. If you do not understand this manual, DO NOT USE the Compressor and contact your Equipment Provider. Explanation of Abbreviations psi lpm Pounds Per Square Inch Liters Per Minute SAFETY Information - Warnings and Cautions DANGER WARNING CAUTION CAUTION Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage. CONSULT ACCOMPANYING DOCUMENTS Type B Equipment DANGER To reduce the risk of electrocution: • Always unplug Easy Comp Compressor immediately after using. • DO NOT use while bathing. • DO NOT place or store Compressor where it can fall or be pulled into a tub or sink. • DO NOT place or drop into water or other liquid. • DO NOT reach for a Compressor that has fallen into water. Unplug immediately. • DO NOT attempt to repair Compressor. Any attempt could result in electrical shock. • DO NOT use near any type of flame or flammable/explosive substances. • DO NOT allow Compressor to exceed operating or storage temperature specifications. • Caution must be exercised when using this Compressor where oxygen is being administered. WARNING To reduce risk of burns, electrocution, fire, or injury to persons: • The Easy Comp Compressor should never be left unattended when running. • Close supervision is necessary when the Compressor is used by, on, or near children or invalids. • Use this Compressor only for its “Intended Use” as described in this manual. • DO NOT use attachments not recommended by Precision Medical, Inc. • DO NOT use Compressor with any equipment that requires “dry” air, including ventilators, gas blenders, or flow generators. • DO NOT use if Compressor has a damaged cord or plug. • DO NOT use if Compressor has been dropped or damaged. • DO NOTcover air vents. Restriction of air flow will cause unit to overheat, causing the thermal reset to shut down the Compressor. • DO NOT drop or insert any object into any opening or hole. • Connect this Compressor to a properly grounded outlet only. See Grounding Instructions. • Keep the cord away from heated surfaces. CAUTION If for any reason any label becomes illegilble or lost, contact Precision Medical, Inc. CAUTION • Inspect the Easy Comp Compressor for visual damage, DO NOT USE if damaged. • Ground reliability can only be achieved when the power cord is connected to an equivalent receptacle marked “Hospital Grade”. SPECIFICATIONS Flow Output at 50 psig: 15 lpm minimum Maximum Rated Sustained Pressure: 60 psi 50% Duty Cycle: Dimensions: Length:10.25 in (26.0 cm) Width: 5.25 in (12.3 cm) Height: 9.5 in (24.1 cm) Weight: 10.8 lbs (4.9 kg) Shipping Weight: 12.5 lbs (5.7 kg) Electrical: 120 VAC, 60 Hz, 5 Amps Operating Temperature Range: 50°F to 104°F (10°C to 40°C) Storage Temperature Range: -4°F to 120°F (-20°C to 49°C) Outlet: Grounded 9/16 - 18 Male Threaded Fitting Safety Systems: High Temperature Motor Shutdown Thermal Protector:Class B, Thermal Limit Automatic Reset This Easy Comp Compressor is not suitable for use in the presence of a flammable anesthetic mixture with air, with oxygen, or with nitrous oxide. Specifications are subject to change without prior notice. COMPONENT IDENTIFICATION CAUTION Missing or illegible labels must be replaced, contact Precision Medical, Inc.. Pressure Gauge air outlet fitting regulator knob suction feet filter endcap air filter assembly power cord keeper on / off switch power cord GROUNDING INSTRUCTIONS The product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electrical current. This product is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. DANGER Improper use of the grounding plug can result in a risk of electrical shock. WARNING Ground reliability can only be achieved when the power cord is connected to an equivalent receptacle marked “Hospital Grade”. OPERATING INSTRUCTIONS WARNING Read this User Manual before installing or operating the Easy Comp Compressor. CAUTION Inspect the Easy Comp Compressor for visual damage, DO NOT USE if damaged. 1. Place Easy Comp Compressor near a properly grounded electrical receptacle on a table, floor or other horizontal , smooth, hard surface. Allow a minimum of 4 in. (10 cm) clearance on all sides to ensure adequate air flow for cooling of product. 2. Press down on product until Suction Feet are secure. 3. Be sure the On/Off Switch is in the “OFF” position. 4. Plug the Compressor into a properly grounded receptacle. 5. Attach appropriate device to the Outlet Fitting, securely, without overtightening. 6. Press the On/Off Switch to the “ON” position. 7. Adjust pressure. To INCREASE pressure - Turn Knob CLOCKWISE To DECREASE pressure - Turn Knob COUNTERCLOCKWISE 8. Begin procedure. 9. When procedure is complete, press the On/Off Switch to the “OFF” position. Cleaning/maintenance WARNING • Turn the Easy Comp Compressor off and disconnect from any external power source before cleaning. • DO NOT attempt to repair. There are no user serviceable parts inside. To clean the filter (weekly): 1. Unplug Compressor. 2. Pry off filter end cap to check air filter for dust buildup. 3.If dust buildup occurs, remove air filter and wash in warm, soapy water and rinse. 4. Absorb excess water from filter with a dry towel. 5. Return filter and end cap. Cleaning for Exterior Components: Use a clean cloth or sponge dampened with soap and water. Wipe dry with a clean cloth or paper towel. CAUTION • Excessive dust buildup on filter will reduce performance of Compressor. If this occurs, clean or replace with a new filter. • The air filter does not filter out saline. Treatments using nebulized saline will draw the saline mist back into the Compressor. Saline cause rapid deterioration of the compressor seals and will void the warranty. returns Returned products require a Returned Goods Authorization (RGA) number, contact Precision Medical, Inc. All returns must be packaged in sealed containers to prevent damage. Precision Medical, Inc. will not be responsible for goods damaged in transit. Refer to Precision Medical, Inc. Return Policy available on the Internet, www.precisionmedical.com. Disposal Instructions Dispose of Bio-waste products as prescribed by your Healthcare Professional or Healthcare Facility Protocol. WARNING If Compressor is used for treatment of infectious disease, consult your Physician or Healthcare Professional for recommended procedures for proper disposal. Please Recycle Replacement Parts Description Filter Assembly Filter (Case -10 ea.) Part Number 1834 1841-10 Troubleshooting If the PM50 Easy Comp Compressor fails to function, consult the Troubleshooting Guide. If the problem cannot be corrected, consult your Equipment Provider. Problem A.Compressor will not operate Probable Cause 1.On/Off switch in “OFF” position 2.Power cord not connected properly 3.Compressor overheated B. Unable to adjust pressure 1. Defective regulator C.Overheating 1.Poor Ventilation 1.Move Compressor to a cooler, better ventilated area 1.Tighten 1.Loose connection at connection outlet fitting 2.Improper 2. Readjust regulator regulator adjustment D.Low pressure Remedy 1.Push On/Off switch to “ON” position 2.Check power cord 3.Shut Compressor off, wait 15 minutes, be sure vents are clear 1.Contact Equipment Provider limited warranty and limitation of liability Precision Medical, Inc. warrants that the PM50 Easy Comp Compressor (the Product) will be free of defects in workmanship and/or material for the following period: One (1) year from shipment Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable repair or replacement at its own expense. ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES. The representatives of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the terms of that contract. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED. Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits, lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical, Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or change product materials, designs, or specifications without notice. Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty. 10 Precision Medical, Inc. 300 Held Drive Northampton, PA 18067 USA Toll Free Tel: 800-272-7285 Toll Free Fax: 800-353-1240 Tel:(+001) 610-262-6090 Fax:(+001) 610-262-6080 www.precisionmedical.com ISO 13485 Certified 1971 Rev7 (E) 05/22/07 Printed in USA
advertisement
Related manuals
advertisement