Honeywell SCT 3000 Configuration Toolkit Installation and Start-Up Guide
إعلان
إعلان
Doc No.: 34-ST-10-08D
Release Date: 3/00
S M A R T L I N E
CONFIGURATION TOOLKIT
SCT 3000
Installation and Start-Up Guide
SCT 3000 Smartline Configuration Toolkit
Notices and Trademarks
Copyright 2000 by Honeywell Inc.
March 8, 2000
While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers.
In no event is Honeywell liable to anyone for any indirect, special or consequential damages. The information and specifications in this document are subject to change without notice.
Honeywell, and TotalPlant are U.S. registered trademarks.
Other brand or product names are trademarks of their respective owners.
ii
Honeywell Inc.
Industrial Automation and Control
Automation College
2820 West Kelton Lane
Phoenix, AZ 85053-3028
1-800 852-3211
SCT 3000 Installation and Start-Up Guide Release 4
03/00
SCT 3000 Smartline Configuration Toolkit
About This Document
Revision Notes
The following list provides notes concerning all revisions of this document.
Doc ID
34-ST-10-08
Rel ID
D
C
Date
03/00
12/98
Notes
Serial interface capability and STT150 support.
Release 200. Flow Compensation Wizard.
References
The following list identifies all documents that may be sources of reference for material discussed in this publication.
Doc ID
34-SM-25-02
Document Title
SMV 3000 Smart Multivariable Transmitter
User’s Manual
ST 3000 Smart Transmitter Release 300
User’s Manual
STT 3000 Version 350 User’s Manual
STT 3000 Series STT250 Operator Manual
STT 3000 Series STT150 Operator Manual
MagneW 3000 Electromagnetic Flowmeter
User’s Manual
MagneW 3000 PLUS Electromagnetic
Flowmeter
34-ST-25-14
34-ST-25-12
EN1I-6190
EN1I-6248
36-KI-25-01
36-KI-25-02
Release 4
03/00
SCT 3000 Installation and Start-Up Guide iii
SCT 3000 Smartline Configuration Toolkit
Contacts
World Wide Web
The following lists Honeywell’s World Wide Web sites that will be of interest to our industrial automation and control customers.
Honeywell Organization
Corporate
Industrial Automation and Control
International
WWW Address (URL)
http://www.honeywell.com
http://www.iac.honeywell.com
http://www.honeywell.com/Business/global.asp
Telephone
Contact us by telephone at the numbers listed below.
United States and Canada
Asia Pacific
Europe
Latin America
Organization
Honeywell Inc.
Industrial Automation and Control
Honeywell Asia Pacific Inc.
Hong Kong
Honeywell PACE
Brussels, Belgium
Honeywell Inc.
Sunrise, Florida U.S.A.
Phone Number
1-800-343-0228
1-800-525-7439
(852) 8298298
[32-2] 728-2111
(305) 364-2355
Sales
Service iv
SCT 3000 Installation and Start-Up Guide Release 4
03/00
SCT 3000 Smartline Configuration Toolkit
Symbol definitions
The following table lists those symbols used in this document to denote certain conditions.
Symbol Definition
This CAUTION symbol on the equipment refers the user to the
Product Manual for additional information. This symbol appears next to required information in the manual.
This WARNING symbol on the equipment refers the user to the
Product Manual for additional information. This symbol appears next to required information in the manual.
WARNING: risk of electrical shock. This symbol warns the user of a potential shock hazard where HAZARDOUS LIVE voltages greater than 30 Vrms, 42.4 Vpeak, or 60 VDC may be accessible.
ATTENTION, Electrostatic Discharge (ESD) hazards. Observe precautions for handling electrostatic sensitive devices
Release 4
03/00
SCT 3000 Installation and Start-Up Guide v
SCT 3000 Smartline Configuration Toolkit
Contents
1— Introduction.................................................................................................. 1
Smartline Configuration Toolkit.............................................................................. 1
Field Devices Supported ....................................................................................... 2
SCT 3000 Features .............................................................................................. 4
2— System Requirements ............................................................................... 7
Before You Begin ................................................................................................. 7
Computer Requirements ....................................................................................... 7
Software Compatibility .......................................................................................... 9
SCT Hardware.................................................................................................... 10
3— Software Installation................................................................................ 13
SCT 3000 Installation.......................................................................................... 13
SCT 3000 Software Application and Setup........................................................... 13
CD ROM Installation........................................................................................... 14
3.5” Diskette Installation ...................................................................................... 15
4— Hardware Installation............................................................................... 17
SCT Hardware.................................................................................................... 17
Smartline Option Module..................................................................................... 17
Serial Hardware Interface (for use with STT 150 only)........................................... 20
5— Start up and Working Online .................................................................. 22
SCT 3000 Application ......................................................................................... 22
Getting Online Quickly ........................................................................................ 22
SCT 3000 Features ............................................................................................ 28
6— Working Offline ......................................................................................... 31
Using the SCT 3000 Offline ................................................................................. 31
7— Online Help................................................................................................ 35
Online Help Features .......................................................................................... 35 vi
SCT 3000 Installation and Start-Up Guide Release 4
03/00
SCT 3000 Smartline Configuration Toolkit
8— Troubleshooting ........................................................................................ 37
Overview............................................................................................................ 37
Troubleshooting SCT Application and PC Card Installation.................................... 38
Troubleshooting SCT 3000 Operation.................................................................. 39
SCT Error Codes ................................................................................................ 42
Status Bar Messages .......................................................................................... 45
Honeywell’s Technical Assistance Center............................................................. 46
Appendix A ....................................................................................................... 47
PC Card Manual Installation and Setup................................................................ 47
Appendix B ....................................................................................................... 54
SCT 3000 Compatibility ...................................................................................... 54
Glossary............................................................................................................ 57
Index.................................................................................................................. 58
Release 4
03/00
SCT 3000 Installation and Start-Up Guide vii
SCT 3000 Smartline Configuration Toolkit
Tables
Table 1 SCT 3000 Computer Specifications - Minimum Requirements .............................................7
Table 2 Smartline Option Module Hardware Specifications ...............................................................10
Table 3 Serial Hardware Interface Specifications..................................................................................11
Table 4 SCT 3000 Application Installation from CD ROM.................................................................14
Table 5 SCT 3000 Application Installation using 3.5” Diskettes .......................................................15
Table 6 Smartline Option Module Hardware Assembly and Installation ..........................................18
Table 7 Serial Hardware Interface Assembly and Installation.............................................................21
Table 8 SCT 3000 Hardware Connections to a Field Device...............................................................23
Table 9 Starting the SCT 3000 Application ............................................................................................25
Table 10 Help Menu Selections ................................................................................................................36
Table 11 SCT 3000 Installation Troubleshooting Table.......................................................................38
Table 12 SCT 3000 Operation Troubleshooting Table .........................................................................39
Table 13 SCT Error Codes and Descriptions .........................................................................................42
Table 14 Status Bar Communication Messages .....................................................................................45
Table 15 PC Card Installation for Computers Operating with
Windows 95 or Windows NT 4.0.............................................................................................48
Table 16 PC Card Installation for Computers Operating with Windows 98 .....................................51
Figures
Figure 1 SCT 3000 Smartline Configuration Toolkit Overview...........................................................2
Figure 2 Smartline Option Module Components ...................................................................................17
Figure 3 Smartline Option Module Assembly ........................................................................................20
Figure 4 Serial Hardware Interface Installation......................................................................................21
Figure 5 Smartline Option Module Connections to Field Device .......................................................23
Figure 6 SCT 3000 Connections to a STT150........................................................................................24
Figure 7 SCT 3000 Banner Window........................................................................................................26
Figure 8 SCT 3000 Application Window................................................................................................28
Figure 9 Online Operation Setup ..............................................................................................................29
viii
SCT 3000 Installation and Start-Up Guide Release 4
03/00
SCT 3000 Smartline Configuration Toolkit
34-ST-16-42
Issue 6
Page 1 of 1
Model Selection Guide SCT 3000 Smartline
Configuration Toolkit
Instructions
Select the desired key number. The arrow to the right marks the selection available.
Make one selection from each table, I, II and III, using the column below the proper arrow.
If no options are desired, specify 00.
A dot ( ) denotes unrestricted availability. A letter denotes restricted availability.
Key Number
_ _ _ _ _ _
I II (Optional)
_ _ _ - _ _ , _ _ _ _ + XXXX
KEY NUMBER
Description
Smartline Configuration Toolkit
TABLE I
None
Cable Length
Installation Guide & Software
6 Ft. - Standard
20 Ft.
None
Inst. Guide & 3.5" Disks - Standard
Inst. Guide & CD ROM
None
Selection
SCT101
0 _ _
_0 _
_1 _
_X _
_ _1
_ _ 2
_ _X
Availability
TABLE II - Options
None
RS-232 Hardware for STT150 Configuration
00
ST
TABLE III
Factory Identification
XXXX
Note: Software upgrades can be ordered through Honeywell Worldwide Software Control.
Please e-mail Sue Shea.
Example: SCT101-002-00 + XXXX
Release 4
03/00
SCT 3000 Installation and Start-Up Guide ix
1— Introduction - Smartline Configuration Toolkit
1— Introduction
Smartline Configuration Toolkit
Honeywell’s Smartline
Configuration Toolkit, SCT 3000 provides a cost-effective
and efficient means to configure, calibrate, diagnose and monitor Honeywell’s Smart field devices. The SCT 3000 is an engineering and maintenance software application designed for ease-of-use and increased productivity. The SCT 3000 runs on a
Windows™-based personal computer specifically to support Honeywell’s Analog and
Digitally Enhanced (DE) protocols in nonhostile, general-purpose field environments.
Toolkit Contents
The Smartline Configuration Toolkit consists of the following items:
1. SCT 3000 software media
Application CD ROM labeled “SCT 3000 Smartline Configuration Toolkit”
-orApplication diskettes labeled “SCT 3000 setup disks”
2. Hardware options -
−
If you ordered the Smartline Option Module, you should have:
(1) PC Card (credit card-size PCMCIA card)
(1) Line Interface Module (LIM) with captive cable
(2) adapter cables (1 with alligator clips; 1 with easy hooks)
−
If you ordered the serial hardware interface, you should have:
(1) Serial hardware interface module
(1) Interface Cable with connectors on both ends
3. Paper documentation
(1) SCT 3000 Start-up & Installation Manual (34-ST-10-08)
Release 4
03/00
Note: An individual order may differ from this list as allowed by the Model Selection
Guide. For example, you may have ordered the SCT 3000 application on CD rather than on diskettes, or you may have opted to omit the SCT 3000 Start-up &
SCT 3000 Installation and Start-Up Guide
1
1— Introduction - Field Devices Supported
Installation Manual from your order. Please check the purchase order against the items shipped in the box. Figure 1 illustrates the components that make up the SCT 3000.
SCT Software Program running on Windows 95, Windows 98 or
Windows NT Operating System
250
Ω
Power
Supply
Smartline Option Modu le
Commerically-available
Laptop or Desktop PC
Smartline Field
Device
PROCESS
RS-232 Serial
Hardware Interface
(For use with STT1 50 only)
Figure 1 SCT 3000 Smartline Configuration Toolkit Overview
2
Field Devices Supported
The SCT 3000 operates and communicates with the following Honeywell Smartline field devices:
•
ST 3000 Smart Pressure Transmitter *
•
ST 3000 Smart Pressure Transmitter with integral meter
•
STT 3000 Smart Temperature Transmitter, (includes Series STT150, STT250 and
STT350 tranmsitters)
•
SMV 3000 Smart Multivariable Transmitter
•
MagneW 3000 & MagneW Plus
* Note that the SCT 3000 will not communicate with older ST 3000 transmitters that are analog only and contain software version 2.2 or earlier, or version 6.1 or earlier.
SCT 3000 Installation and Start-Up Guide Release 4
03/00
1— Introduction - SCT 3000 Features
The SCT 3000 Online User Manual provides useful configuration and diagnostic information for the supported field devices. More detailed information for configuring and operating these field devices is found in separate user manual and operating guide documents that support each field device. See References on Page iii in the front of this document for a list of these documents.
SCT 3000 Features
The Smartline Configuration Toolkit has all of the following features:
•
Windows-based software application allows easy access to all Smartline configuration and calibration device parameters.
−
SCT 3000 runs on computers with Windows 95, Windows 98, or Windows NT operating systems.
−
Employs familiar Windows tools that include an online user manual and context sensitive help.
−
Device database parameters are arranged and presented in logically grouped “tab card” displays.
•
Online and Offline Mode operation
−
Offline mode allows you to configure and save database files for various devices without being connected to the device.
−
In the online mode you can download the saved databases to the devices and perform online functions such as:
Selection of the Communications Mode (Honeywell DE or analog)
Configuration and device diagnosis
Calibration
Display of device parameters
Device check out
•
Built-in Database Templates
−
Default database templates are provided for each type of field device to simplify and reduce implementation time and effort.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
3
1— Introduction - SCT 3000 Features
•
Database Verification
−
Database parameters are checked for “reasonable” values automatically to help avoid mistakes.
−
A database compare function detects differences between the device database and the SCT database providing assurance of proper installation.
•
PV Monitoring
−
Graphical representations of device inputs and outputs are shown in a window so you can monitor the operating status of Smartline field devices.
−
Window shows you values of input PVs, output PVs and SVs of the connected device in real time.
•
Flow Wizard
−
A built-in wizard that provides considerable time savings and ease of use for you when configuring the flow process variable in a Smart Multivariable Transmitter
(SMV 3000). By providing responses to configuration questions and choices in a step-by-step progression, you can configure the flow variable (PV4). Upon completion, a configuration solution is generated by the wizard that can be saved as a database file and downloaded to the field device.
Windows operating system references
Use of the SCT 3000 is based on the Windows 95, Windows 98 and Windows NT 4.0
operating systems. So, before you begin to use the SCT 3000 it is important to know how to perform basic operations with your computer and with Windows. The information and procedures presented in this manual assume you are already familiar with Windows. If necessary, you may find it useful to review the following reference manuals from Microsoft before proceeding:
•
Getting Started with Microsoft Windows - a guide to setting up Windows on your system and a brief introduction to Windows.
•
Microsoft Windows User’s Guide - provides a comprehensive description of Windows; includes explanations and procedures for first-time users, in addition to topics for advanced users.
•
Microsoft Windows Tutorial - provides online instructions for using a mouse and for performing some basic tasks in Windows.
4
SCT 3000 Installation and Start-Up Guide Release 4
03/00
2— System Requirements - Before You Begin
2— System Requirements
Before You Begin
Before you install the SCT on your computer and start using it, there are a number of system requirements for the computer you will be using that will ensure trouble-free installation and operation with the SCT 3000 application.
Computer Requirements
The SCT 3000 software application runs on a variety of commercially-available portable or desktop computer platforms that may also be shared with other applications. Table
1lists the system capabilities needed to install and operate the SCT 3000 application.
Table 1 SCT 3000 Computer Specifications - Minimum Requirements
PC Specification
CPU
Display
Operating System
Computer:
Laptop or Desktop PC
Pentium 90 MHz or better
SVGA (Monochrome or Color)
Windows 95, Windows 98 or Windows NT 4.0
(Note: Windows 95b or greater is recommended.)
Mouse or trackball-compatible device
Pointing Device
Power Source
Laptop PC
Desktop PC
RAM
Application Size
Floppy Disk Drive
Laptop PC
Desktop PC
Battery powered (see Note 1)
AC powered (see Note 1)
16 MB (32MB recommended). See Note 2.
12 MB (application) + 5 kB per database file
See Note 3
(1) 3.5-inch, 1.44MB drive
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
5
2— System Requirements - Computer Requirements
PC Specification Computer:
Laptop or Desktop PC
CD ROM Drive
Laptop PC
Desktop PC
Ports
PCMCIA Slot
Card & Socket Services
(only if needed)
Optional
4x or higher
Parallel: Printer (see Note 4)
Serial: For STT150 support (See Note 3)
(1) Type II PCMCIA slot (see Notes 5 and 6)
PhoenixCARD Manager Plus V3.1/3.2
(Phoenix Technologies, Ltd.)
SystemSoft Card WizardPro 3.1
NOTES:
1.
Computer power source (and laptop PC’s battery charger and/or AC adapter) must be suitable for worldwide use: 50-60 Hz and 100-220 VAC operation; also, battery should provide enough capacity to power the PC
Card without derating life by more than 10%.
2.
Minimum RAM capacity is 4 MB, but ROM-based portable PCs may be able to run with only 2 MB.
3.
These functions require laptop PCs to have a floppy disk drive, serial port or other mechanism for file transfers:
- installation of SCT 3000 software and updates
- configuration database import and export
4.
SCT 3000 software supports any Windows 95 (or greater)-compatible printer.
5.
The interface hardware requires a PCMCIA Type II slot; it may be necessary for the desktop computer to have a PCMCIA adapter installed to accommodate the interface hardware.
Compatible PCMCIA adapters include Greystone Peripherals Card Dock GS315.
6.
To use the SCT 3000 on a desktop computer without a PCMCIA slot, you must install a PCMCIA host adapter. See your Honeywell sales representative for more information.
6
SCT 3000 Installation and Start-Up Guide Release 4
03/00
2— System Requirements - Software Compatibility
Computer models for use with SCT 3000
The following computers, which are commercially-available portable or desktop PCs, have been performance-qualified by Honeywell for use with the Smartline Configuration
Toolkit:
•
COMPAQ Armada 1592
•
COMPAQ Elite 5300
•
Dell 466M desktop PC
•
Dell Dimension XPS P90 desktop PC
•
Dell Latitude CP
•
Dell Latitude XP laptop PC
•
Dell Latitude XPi laptop PC
•
Dell Optiplex XMT P90
•
Dell 433/T
•
Dell 450/ME
•
Dell Optiplex GXa
•
Dell Optiplex GXi
•
Gateway GS180
•
IBM ThinkPad 600
•
IBM ThinkPad 760XL
•
NEC Versa 2730MT
•
Panasonic Toughbook CF71
•
Toshiba Tecra 550CD
The SCT 3000 operates on any computer platform listed above that meets the application’s minimum specification requirements as listed in Table 1. The individual PC vendor furnishes detailed information of the user-supplied computer platform.
Software Compatibility
The SCT 3000 may coexist with the following application programs on a computer.
•
Microsoft Word 6.0, Access 1.0, Excel 5.0, Office and Qsystem.
The import/export capabilities of SCT database files allow for only “tab” delimited text files.
Refer to Appendix B in this document for further information on software compatibility.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
7
8
2— System Requirements - SCT Hardware
SCT Hardware
Communication between a computer running the SCT 3000 application and the field device is accomplished through one of two hardware interfaces:
1. The Smartline Option Module is used to talk to all Honeywell field devices supported by the SCT 3000, (except the STT 150). See Table 2 for specifications.
2. A Serial Hardware Interface is used only when communicating to the STT 150 smart temperature transmitter. See Table 3 for specifications.
Each of these hardware interfaces is described in Section 4, Hardware Installation.
Environmental specifications for SCT hardware
The SCT is designed to operate in a non-hostile, general purpose field environment. It is important to operate the SCT in an environment that is within the ranges for temperature, humidity, shock and vibration that are specified in Table 2 and Table 3.
WARNING
The SCT 3000 is not certified for use in hazardous locations .
Table 2 Smartline Option Module Hardware Specifications
Specification
Communication Protocol
Description
Compatible with Honeywell Smart Field
Network (SFN).
Temperature Range
Operating
Storage
Operating Humidity Range (RH)
Shock Range (LIM)
Operating
Storage Range
0
°
C to +40
°
C (32
°
F to +104
°
F), ambient
-4
°
C to +55
°
C (25
°
F to +131
°
F), ambient
10-90%, noncondensing
5 G, maximum
15 G, maximum
Table continued on next page
⇒
SCT 3000 Installation and Start-Up Guide Release 4
03/00
2— System Requirements - SCT Hardware
Specification
Vibration Range (LIM)
Operating
Description
Storage Range
0.2 G, maximum
(0-2 kHz, 0.75 mmP-P, maximum displacement)
0.5 G, maximum
(0-2 kHz, 0.75 mmP-P, maximum displacement)
0.5 lbs., maximum
Weight (PC Card, LIM + cables)
Approval Bodies
NORTH AMERICA
EUROPE
EMC Standards:
FCC Class A
European EMC Standards:
EEC Directive 89/336 (EMC)
CE Mark
Release 4
03/00
Table 3 Serial Hardware Interface Specifications
Specification
Communication Protocol
Computer interface
Baudrate
Field device inteface
Description
Compatible with RS232 Protocol
Compatible with 5Vdc level or 3Vdc level
19200 bps, maximum
9600 bps, typical
Temperature Range
Operating
Storage
Operating Humidity Range (RH)
Electrical Isolation
Cable length
Computer interface (RS232)
Field device interface
0
°
C to +50
°
C (32
°
F to +122
°
F), ambient
-40
°
C to +85
°
C (-40
°
F to +185
°
F), ambient
10-90%, noncondensing
250 Vac
10 meters, maximum
3 meters, maximum
Weight (Interface module + cable)
0.5 lbs., maximum
Approval Bodies
Mark CE
SCT 3000 Installation and Start-Up Guide
9
3— Software Installation - SCT 3000 Installation
3— Software Installation
SCT 3000 Installation
Installation of the SCT 3000 is broken down into two separate procedures:
1. Software installation
2. Hardware assembly and installation, (described in Section 4).
Note: Install the software first, before the hardware.
SCT 3000 Software Application and Setup
The SCT 3000 software application and Installation Utility are available on a CD ROM or 3.5” diskettes. Depending upon which media you choose for installation (CD or diskettes), follow the appropriate procedure in this section.
Running the installation utility
The SCT 3000 software application is installed on your computer using the installation utility. The utility creates all necessary directories, files, application groups and/or items to run SCT application. The utility also updates the registry and checks for adequate system resources, such as disk space and Windows version number.
The installation utility provides a step-by-step procedure for installing the SCT 3000 application on your computer. You must follow the procedure and the appropriate prompts in the utility to properly install the application. You cannot simply copy the files from the CD or diskettes to your hard drive.
It is recommended that you close any other applications you have running in Windows as these can greatly increase the time for installing your SCT 3000 application.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
11
3— Software Installation - CD ROM Installation
CD ROM Installation
The SCT 3000 CD is designed to automatically start the installation utility when you insert it in your computer's CD drive. On-screen prompts should guide you through the install program. Follow the procedure in Table 4 to run the installation utility and setup.
Table 4 SCT 3000 Application Installation from CD ROM
Step
1
Action
Insert the SCT 3000 CD into the CD-ROM drive.
2
3
If the SCT 3000 Installation Utility does not start after several seconds:
•
On the desktop of the computer, click on “My Computer”
•
Click on the CD drive icon.
The SCT 3000 Installation Utility will start.
The Installation Utility will lead you through installation of the SCT 3000 application software. On-screen prompts allow you to choose options on where you want the SCT application installed.
4
Follow the on-screen instructions and answer the prompts to install the application software.
5
6
7
Wait for the Setup Complete dialog box to appear.
Remove the CD from the CD-ROM drive.
Click “Finish” to exit.
You must restart the computer before you can run the SCT 3000 application.
Go to Section 4 – Hardware Installation to assemble and install the SCT 3000 hardware.
12
SCT 3000 Installation and Start-Up Guide Release 4
03/00
3— Software Installation - 3.5” Diskette Installation
3.5” Diskette Installation
The procedure in Table 5 provides the steps to run the installation utility using 3.5” diskettes. Once the utility starts, on-screen prompts should guide you completely through the setup and SCT 3000 application installation. Note that you must follow the on-screen instructions and answer the prompts to complete the SCT 3000 installation.
You cannot simply copy the files from the setup disks to your hard drive.
Step
1
2
Table 5 SCT 3000 Application Installation using 3.5” Diskettes
Action
Make a backup copy of the original SCT 3000 setup disks and store them in a safe place.
Insert the SCT 3000 Setup Disk 1 into the floppy disk drive of the computer.
3
Click the “Start” button.
Select:
”Settings”,
”Control Panel”,
”Add/Remove Programs”
From the Install/Uninstall tab card, select “Install. . .” and follow directions
Click ”Next >” and then “Finish”.
4
5
6
7
Wait for the Honeywell SCT 3000 Installation Utility screen to appear.
Click ”Next >” if you wish to continue and install the SCT 3000 application.
The Installation Utility will lead you through installation of the SCT 3000 application software. On-screen prompts allow you to choose options on where you want the SCT application installed.
Follow the on-screen instructions and answer the prompts to install the application software.
Wait for the Setup Complete dialog box to appear.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
13
3— Software Installation - 3.5” Diskette Installation
Step
8
Action
Remove the setup diskette from the floppy drive.
Click “Finish” to exit.
You must restart the computer before you can run the SCT 3000 application.
9
Go to Section 4 – Hardware Installation to assemble and install the SCT 3000 hardware.
14
SCT 3000 Installation and Start-Up Guide Release 4
03/00
4— Hardware Installation - SCT Hardware
4— Hardware Installation
SCT Hardware
As part of the SCT 3000 installation, you must assemble the hardware interface components and then connect them to the computer that you will use with the SCT software application. There are two hardware interfaces available for use with the SCT:
1. Smartline Option Module described below
2. Serial hardware interface (for use with STT 150 only) which is described later in this section.
Note: Install the software first, before the hardware.
Smartline Option Module
Smartline Option Module is used to connect and communicate with all Smartline field devices supported by the SCT 3000, except for the STT 150 transmitter. The components are illustrated in Figure 2 and described below.
PC Card
(PCMCIA card)
Adapter Cable
Line Interface
Module
Alligator Clips or
Easy Hooks connect to terminals of Smart field device
Captive Cable
Figure 2 Smartline Option Module Components
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
15
4— Hardware Installation - Smartline Option Module
The PC Card is a Type II PCMCIA-compliant interface card that provides the physical and electrical interface between the computer and the Line Interface Module
(LIM).
The Line Interface Module (LIM) connects between PC Card and
DE-based 4-20 mA loop (the module is powered solely from computer).
A captive cable connects the PC Card and the LIM.
The adapter cable is used to connect the LIM to the field device. The SCT is shipped with two adapter cables. One cable is equipped with easy hooks and the other has alligator clips at the field device end of the cable.
Smartline Option Module hardware assembly and installation
Perform the procedure in Table 6 to assemble and install the SCT 3000 Smartline Option
Module hardware for the first time. See Figure 3 for reference during this procedure.
16
Table 6 Smartline Option Module Hardware Assembly and Installation
Step
1
Action
Ensure that the power to the computer (PC) is off.
2
Insert the keyed 22-position connector on the end of the LIM’s (Line Interface
Module’s) captive cable into the 22-position receptacle on the exposed end of the PC Card (PCMCIA card) (see Figure 3). If you have trouble inserting the connector, try flipping it over and reinserting or verify that the retractable positive latch is retracted. Fasten the connector securely with the retractable positive latch.
3
4
5
Securely fasten the stereo phone jack end of one of the adapter cables into the connector on the opposite end of the LIM.
Carefully insert the PC card into the PCMCIA slot of the computer. Insert the card completely until it mates with the internal connector. See Note below.
Go to Section 5 – Start up and Working Online for information on connecting the hardware interface to a field device and starting the SCT 3000 application.
Note:
If your computer does not have a PCMCIA slot, you can install a PCMCIA host adapter so that you can use the Smartline Option Module for online operation. See your Honeywell sales representative for more information.
SCT 3000 Installation and Start-Up Guide Release 4
03/00
4— Hardware Installation - Serial Hardware Interface (for use with STT 150 only)
To Computer
PCMCIA Slot
Step 2
PC Card
Step 3
Line Interface
Module
Figure 3 Smartline Option Module Assembly
CAUTION
To prevent component damage or loss of data during operation from electrostatic discharge, always note the following precautionary measures:
•
Always connect or disconnect the PC Card and LIM from the computer as a single assembly.
•
Never insert or remove the PC Card and LIM assembly from the computer while the SCT 3000 application is running.
•
Separate the PC Card and LIM only for storage or transportation.
Serial Hardware Interface (for use with STT 150 only)
A serial hardware interface is available to use with the SCT 3000 when communicating with the STT 150 Smart Temperature Transmitter. The interface consists of the following components:
•
Serial Interface Module which is an RS-232 standard hardware interface (9-pin
D-type connector) that provides the physical and electrical interface between the computer and the field device. See Figure 4.
•
An Interface cable connects the serial interface module to the field device. The cable features a 4-pin connector for the interface module connection and a 3-pin connector at the field device end.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
17
4— Hardware Installation - Serial Hardware Interface (for use with STT 150 only)
To Serial port on computer
Serial Hardware
Interface Module
4-pin connector
Interface Cable
To STT 150
Transmitter
Figure 4 Serial Hardware Interface Installation
Follow the steps in Table 7 to assemble and install the serial interface hardware.
Table 7 Serial Hardware Interface Assembly and Installation
Step
1
Action
Ensure that the power to the computer (PC) is off.
2
Insert the 9-pin D-type connector of the serial interface module into an available serial port connector on the computer and secure using the two captive mounting screws. See Figure 4.
Notes:
•
Connect the interface module to an available serial port (COM 1 or 2) on the computer for SCT 3000 use.
•
The COM port also must be set in the SCT 3000 application. See Set
COM Port topic in the index of the Online User Manual for more information.
3
4
Insert the interface cable end (4-pin) into the 4-pin connector on the serial interface module.
Go to Section 5 – Start up and Working Online for information on connecting the hardware inteface to a field device and starting the SCT 3000 application.
18
SCT 3000 Installation and Start-Up Guide Release 4
03/00
5— Start up and Working Online - SCT 3000 Application
5— Start up and Working Online
SCT 3000 Application
The SCT 3000 application is an easy-to-use graphical user interface that is similar in functionality to any other Windows-based application. Start up procedures consist of connecting the SCT hardware to a field device and establishing online communications with the devce. Also this section describes the SCT 3000 application window, its various components, and how to access the menus and commands to gain more insight into the
SCT features.
Getting Online Quickly
The following procedures tell you how to:
•
Connect the SCT 3000 hardware to a field device.
•
Make an online connection to commnicate with a field device.
•
Perfrom online tasks, such as view device parameters, check device status and perform online configuration or device calibration.
Connecting to a field device
WARNING
The SCT 3000 is not certified for use in hazardous locations .
ATTENTION
The SCT 3000 can be connected to only one Smart field device at a time.
Perform the procedure in Table 8 to connect the assembled SCT 3000 hardware between the computer and the Smartline field device.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
19
5— Start up and Working Online - Getting Online Quickly
Step
1
Table 8 SCT 3000 Hardware Connections to a Field Device
Action
The SCT hardware must be assembled and installed according to the procedures in Section 4.
•
If you are using the Smartline Option Module, follow the procedures in
Table 6 to assemble the hardware. Then go to Step 2.
•
If you are using the Serial hardware interface, follow the procedure in
Table 7 to assemble the hardware. Then go to Step 3.
2
If you are using the Smartline Option Module, Connect the easy hooks or alligator clips on the end of the adapter cable to the respective terminals on the Smart field device or field terminals as follows (See Figure 5.):
-- connect the red lead to the positive terminal.
-- connect the black lead to the negative terminal.
20
Laptop PC
Smart Field Device
Terminal Block
M E T E R
L S I GNA L
250
Ω
Field
Terminals
Black
Red
24Vdc
Adapter Cable
Figure 5 Smartline Option Module Connections to Field Device
The Smartline Option Module must be connected to a powered loop with at least 250 ohms of resistance.
SCT 3000 Installation and Start-Up Guide Release 4
03/00
5— Start up and Working Online - Getting Online Quickly
ATTENTION
Do not disconnect or insert the PC Card (or serial interface module) to the computer while running the SCT3000 application.
Step
3
Action
If you are using the Serial hardware interface, plug the interface cable end
(3-pin) into the connector on the STT150 transmitter. See Figure 6.
Interface cable connected to serial interface module
Laptop PC
1
+
To RS232 serial port
24Vdc
Sensor
Inputs
3
STT150
Transmitter
_
250
Ω
Interf ace cable connector
Figure 6 SCT 3000 Connections to a STT150
The Serial Hardware interface must be connected to a powered loop with at least 250 ohms of resistance.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
21
5— Start up and Working Online - Getting Online Quickly
Starting the SCT 3000 application
The steps in Table 9 tell you how to start the SCT 3000 application and establish online communications with the connected field device.
Table 9 Starting the SCT 3000 Application
Step
1
Action
Power up the computer and allow the PC to start up.
2
In Windows 95, 98 or NT:
Click the “Start” button.
Select:
”Programs”,
”Smartline Configuration Toolkit”,
”SCT 3000” to start the SCT 3000 application. See figure.
22
Note:
•
Alternately, you can click the SCT 3000 icon from the computer desktop to start the SCT 3000 application.
•
The SCT 3000 main application window also offers the following file:
SCT 3000 Help File – make this selection to access the SCT 3000 help system; refer to Online Help Features in Section 7 for a complete description of the online help system.
SCT 3000 Installation and Start-Up Guide Release 4
03/00
5— Start up and Working Online - Getting Online Quickly
Step
3
Action
When the SCT 3000 Banner Window appears (see Figure 7), type in your designated user name in the name entry field. Note that you must enter a user name that is at least three (3) alphanumeric characters long. Any spaces before or after the user name string will be dropped off when the
Banner Screen appears.
Click the “Cancel” button at any time to exit out of the SCT 3000 banner window and application.
Click the “Help” button at any time to access the SCT 3000 Help system.
4
Click “OK” to access the SCT 3000 application. The SCT 3000 application window (see Figure 8) immediately appears on the screen.
Release 4
03/00
Figure 7 SCT 3000 Banner Window
SCT 3000 Installation and Start-Up Guide
23
5— Start up and Working Online - Getting Online Quickly
Step
5
Action
Check the status bar at the bottom right of the application window. CARD
OK or SERIALOK should appear to indicate that the SCT 3000 detects the
SCT hardware and a connected field device. This is the online status of the
SCT 3000.
If not, a loose hardware connection or possible communications problem may exist. See Section 8, Troubleshooting and Appendix A.
6
7
8
In the Device menu:
Select “Upload” (or click on the Upload toolbar button) to upload the current database configuration from the connected device and make the online connection.
•
A Communications Status dialog box displays during the uploading process.
When upload is complete, the online view of the connected field device appears on the screen. The window shows a number of tabs which contain various parameters that make up the device’s configuration database.
Access the Status tab by clicking on its tab. The Status tab is used to verify the status of the connected field device.
•
Separate boxes for Gross Status and Detailed Status messages are presented in the Status tab. Refer to the SCT 3000 online User Manual for explanations of each status condition.
Click on the various tabs in the application window to view configuration parameters and device status.
Note:
See Section 6 – Working Offline for procedures to create new database files.
TIP
Once you have started the SCT 3000 application, you can access the online help topics and context-sensitive help that describe all features in the application window. See Online Help Features in Section 7. Also there is the online user manual that provides extensive information on how perform all offline and online tasks.
24
SCT 3000 Installation and Start-Up Guide Release 4
03/00
5— Start up and Working Online - SCT 3000 Features
SCT 3000 Features
SCT application window
The SCT 3000 application window (see Figure 8) is the main window that appears when starting up the SCT 3000 application. This window allows access to all available SCT
3000 menus and commands.
Release 4
03/00
Figure 8 SCT 3000 Application Window
The functional elements in the SCT 3000 application window that are unique to the application are briefly explained here.
•
Control icon displays the SCT icon at the left corner of the application window.
•
Menu bar contains headings so you can access individual groups of drop-down menus
and commands that are selectively available in the application.
•
Toolbar appears across the top of the application window below the menu bar, when
selected for display. The toolbar features a number of icons that provide quick mouse access to many commands used in the SCT 3000. To display (or hide) the toolbar, use the Toolbar command in the View menu.
SCT 3000 Installation and Start-Up Guide
25
5— Start up and Working Online - SCT 3000 Features
•
Status bar appears at the bottom of the SCT 3000 application window, when selected
for display. The status bar tells you to press F1 key to access the online help and also displays the status of the online connection to the field device. To display (or hide) the status bar, use the Status Bar command in the View menu. See Section 8 for more information on status bar messages.
•
Standard application window features - We assume you are already familiar with
the concepts of the title bar, maximize, minimize and close buttons and scroll bars. If not, refer to the appropriate Windows manual for descriptions of each element.
Toolbar icons
The toolbar in the SCT application window contains a row of icons (shown below) that select commands frequently used when operating with the SCT. By moving the cursor over the icon, the name of the command is displayed. You can also use the contextsensitive feature to display the help topic about each icon.
Online vs. Offline
Working online with the SCT 3000 entails communicating with a field device that is connected to the computer via one of the hardware interfaces, as shown in Figure 9.
Power
Supply
250
Ω
Adapter
Cable
Laptop or
Desktop PC
26
Smartline Option Module
Smartline Field
Device
Figure 9 Online Operation Setup
SCT 3000 Installation and Start-Up Guide
PROCESS
Release 4
03/00
5— Start up and Working Online - SCT 3000 Features
Working online
Working online allows you to:
•
Download a database file to the connected field device during installation or commissioning of your process application.
•
Upload database from the connected field device to verify device configuration and make changes, if necessary.
•
Monitor device output and status with the data and status being periodically refreshed.
The PV Monitor display window graphically shows you values of input PVs, output
PVs and SVs of the connected device in real time. View device status messages for detection, diagnosis and troubleshooting of possible fault conditions.
•
Perform field calibration on the connected device.
•
Change communications mode of the field device (analog mode or DE)
Working offline
Working offline means that you are using the SCT 3000 application without being connected to a field device. Working offline allows you to:
•
Perfrom database management of database files. This entails creating or changing device configuration database files, saving the files to disk for downloading at a later time.
•
Compare one database file with another. See Section 6 for more details.
•
Print database files. See Section 6 for more details.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
27
6— Working Offline - Using the SCT 3000 Offline
6— Working Offline
Using the SCT 3000 Offline
Working offline with the SCT 3000 means that you are using the SCT application without being connected to a field device. You can work at a location away from the field network. Working offline allows you to manage Smartline field device database files.
Database file management
You can create, copy, transfer and change configuration database files for supported field devices.
To create a new database file:
Step
1
2
3
4
5
Action
In the File menu,
Select New, (or click on the “New” icon on the toolbar).
The Add New Template dialog appears.
Click on one of the three tabs to display a list of available templates for supported field devices.
−
Honeywell Templates lists preconfigured templates for various models of Honeywell field devices. Use the Device Filter box to select templates for a particular device type.
−
User Templates shows a list of previously saved database file templates.
−
A Generic Template can be used to view and modify a device’s extended parameter data.
Select a template name and click OK.
The configuration tabs for the device type appear on the screen.
Now you can enter and change the parameters on the tabs for a specific device in a process application.
Click the “Save” icon on the toolbar and enter a unique filename for the device database file.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
29
6— Working Offline - Using the SCT 3000 Offline
To open an exisitng database file:
Step
1
In the File menu,
Action
Select Open (or click on the “Open” icon on the toolbar).
The Open dialog will appear to show the existing database files (.sct) in the
Templates folder.
2
Double click on a file name to open it.
3
The configuration tabs for the device type appear on the screen.
Now you can enter and change the parameters on the tabs for a specific device.
4
Click the “Save” icon on the toolbar to save changes to the database file.
Parameter checking
When entering configuration parameters in a database file, the SCT 3000 automatically verifies and validates each selected parameter relationship with other parameters associated with the given field device. If entry of one parameter results in other parameters becoming invalid, the SCT automatically disallows entry of the invalid parameter. This ensures that the configuration can be downloaded to the field device without any resulting errors.
Printing a database document
The SCT 3000 actively maintains a printable document that provides summary information for the configuration (and Wizard) database associated with each Smart field device. Each document lists the individual parameters and associated values for each device’s configuration database.
To print a database file:
Step
1
2
Action
The database file must open and the configuration window must be active.
3
Click on the “Print” icon on the toolbar. The Print dialog appears.
If neccessary, select printer, page numbers and number of copies.
Click “OK”
30
SCT 3000 Installation and Start-Up Guide Release 4
03/00
Database Compare function
A Database Compare function in the SCT 3000 allows you to compare either two configuration windows for differences or the active configuration window and a designated configuration file.
To compare the database files of two configuration windows for differences:
Step
1
In the Device menu,
Action
Select Compare To… > Window….
The Compare: Select Window dialog will appear to show the other configuration windows open.
2
Double click on a filename to compare it to the active configuration window database.
3
A Compare Results window shows the differences between the two database files.
To compare the database file of the current configuration window to another database file:
Step
1
2
3
Action
In the Device menu,
Select Compare To… > File….
The Open dialog will appear to show the existing database files (.sct) in the
Templates folder.
Double click on a filename to open the database file and compare it to the active configuration window database.
A Compare Results window shows the differences between the two database files.
Compare Results
The Compare Reuslts window shows a list of all parameters that are contained in both the current window and the designated window or database file but which contain different configuration values. Note that when an attempt to compare database files for two dissimilar devices, (for example an ST 3000 and an SMV 3000), the Compare Results will list only the Transmitter Type in the results window.
Release 4
03/00
6— Working Offline - Using the SCT 3000 Offline
SCT 3000 Installation and Start-Up Guide
31
7— Online Help - Online Help Features
7— Online Help
Online Help Features
Online help features allow easy access to information for using the SCT 3000 application. Three types of help are built-in to the SCT.
1. Online Help Topics –SCT 3000 Help topics can be accessed through a Table of
Contents or by using the Index and Find function. These functions enable you to locate information about specific topics while in any SCT window.
2. Context-sensitive Help – A help topic can be displayed on a particular item you select simply by requesting help and selecting the item.
3. Online User Manual – An online document that provides extensive information on how to configure, calibrate, diagnose and monitor the field devices supported by the
SCT 3000.
Accessing help
Help topics can be accessed a number of ways.
•
From the Help pull down menu, which is accessible from the SCT 3000 menu bar, choose a help category (see Table 10).
•
Press F1 while focused on a particular window, entry or selection field, menu item or dialog box option.
•
Choose the Help command button that is available in many dialog boxes and configuration forms.
•
Click on the context-sensitive help button on the toolbar and then click on any particular item.
Context-sensitive help icon is located on toolbar.
TIP
The Help topics and online user manual provide extensive information about
SCT application features and all available online and offline tasks for field device operation.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
33
7— Online Help - Online Help Features
Table 10 lists the Help menu selections available to you along with a description of the help feature.
Table 10 Help Menu Selections
Help Menu
Selection
Tip of the Day ...
Help Feature
Displays help tips about using the SCT 3000 Smartline
Configuration Toolkit.
Help Topics
User Manual
Opens a window so you can access the SCT 3000 Help topics by using Help’s Table of Contents or by selecting an Index or
Find search function.
Contents
Opens a window that displays the “Contents for SCT 3000
Application Help” page which lists each top-level help topic in the general help application.
STT150 Operator
Manual
Opens a copy of the STT150 Temperature transmitter operator manual. This selection is available only if you are connected to a STT150 transmitter.
Opens the SCT 3000 online user manual, which lists the various sections of information available within the manual.
Using Help
Opens a window so you can access topics about using
Windows help. These topics explain the basics on the Windows help structure and how to access help information.
Note that SCT help topics operate similarly to the information contained in the Windows help.
34
SCT 3000 Installation and Start-Up Guide Release 4
03/00
8— Troubleshooting - Overview
8— Troubleshooting
Overview
If trouble arises, it may happen during installation of the SCT 3000 application or during normal operation. Due to differences in computer systems, problems are not always predictable. However this section seeks to provide some suggestions on possible remedies to problems that may occur during installation or operation of the SCT 3000 application.
First this section provides troubleshooting suggestions to help clear up problems. Next, is a listing of all the error codes and communication status messages that are generated by the SCT 3000 application. Last, information and phone contacts to reach Honeywell
Technical Assistance are provided if the information in this manual or in the SCT application does not address or remedy a problem.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
35
8— Troubleshooting - Troubleshooting SCT Application and PC Card Installation
Troubleshooting SCT Application and PC Card Installation
Please note the following considerations when encountering problems with the SCT 3000 application or PC card installaton:
•
You can install the SCT 3000 application software on a computer that does not have
PCMCIA card slots or serial ports. The SCT 3000 will run correctly on these computers but you may only be able to operate in the offline mode.
•
If your computer does not have a spare PCMCIA slot, you can install a PCMCIA host adapter so that you can use the Smartline Option Module for online operation. See your Honeywell sales representative for more information.
•
When using the Smartline Option Module as the hardware interface, make sure that the SCT PC Card is inserted into the computer’s PCMCIA card slot.
If you are encountering problems while running the SCT 3000 installation utility or if you are using the procedures in Appendix A to install and setup the PC card, use the troubleshooting Table 11 to find the symptom and refer to the action to correct the trouble.
Table 11 SCT 3000 Installation Troubleshooting Table
Symptom
The “Add New Hardware” dialog box appears when the
PC card is inserted in the computer’s PCMCIA slot for the first time
Probable Cause
The computer does not recognize the PC card.
Corrective Action
Remove the PC card from the computer slot and then install the SCT 3000 software.
Unable to complete setup procedure for SCT 3000 application installation.
Insufficient disk free space on computer.
For computers with Windows
NT operating systems:
Unable to run setup and installation utility for SCT
3000 application.
You do not have write
(Admin) privileges in the directories specified for the installation.
Check to make sure that there is enough free disk space on the computer’s fixed disk to allow installation of the SCT
3000 application and its associated files.
The system requirements for application size are listed in
Table 1.
See your system administrator.
36
SCT 3000 Installation and Start-Up Guide Release 4
03/00
8— Troubleshooting - Troubleshooting SCT 3000 Operation
Troubleshooting SCT 3000 Operation
To avoid problems that may occur during initial start-up of the SCT 3000 application, install the SCT 3000 software before installing any SCT hardware.
The troubleshooting Table 12 describes conditions that may occur when running the SCT
3000 application. Probable causes and things to do in order to correct the condition are also given.
Table 12 SCT 3000 Operation Troubleshooting Table
Symptom
Unable to establish online connection with field device.
Probable Cause
Loose hardware connection between computer and field device.
Corrective Action
Check all hardware connections.
Status bar message:
NO CARD or BAD CARD –
COM UNKNOWN
If you are using the Smartline
Option Module: a) Hardware components are not properly assembled.
a) See Section 4, Table 6 for assembly procedure.
b) Hardware is not properly connected between the computer and the Smart field device.
c) PC card is not the current version (2.0 or greater) for use with the SCT
3000 release.
d) PC card not recognized by computer. PC card disabled. (Windows
95/98 only).
e) The Smartline Option
Module is not properly installed.
b) See Section 5, Table 8 for connection procedure.
c) Check PC card version. In the Help menu, select: About
PC Card… Obtain PC card that is version 2.0 or greater.
d) Verify the PC card’s disable setting in the computer’s control panel. Select: Control Panel
à
System
à Device Manager à
Other Devices
à SCT Option
Module. Click on General tab.
Verify that “Disable” or” Disable in this hardware profile” is NOT checked.
e) See Appendix A, Table 15 or
Table 16 for PC card manual installation procedure.
Table continued on next page
⇒
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
37
8— Troubleshooting - Troubleshooting SCT 3000 Operation
Symptom
Unable to establish online connection with field device.
Status bar message:
NO CARD or BAD CARD –
COM UNKNOWN
Communication errors when trying to connect online to a field device.
Probable Cause
If running Windows NT operating system:
PC card installed while computer is powered on.
Corrective Action
Turn off power to computer before inserting PC card onto
PCMCIA slot.
If you are using the serial hardware interface:
a) Hardware components are not properly connected.
b) Serial port not selected.
OR c) Serial port being used by another application or device. (Other software applications running on the computer may use the serial port, thus making it
“unavailable” for SCT
3000 communications.) a) See Section 4, Table 7 and Section 5, Table 8 for hardware connection procedures.
b) and c)
Make sure that the serial port on the computer is available for use with the SCT 3000 serial hardware interface.
In the SCT 3000 View menu, select Options… Click the
General tab. Select a Serial port name that corresponds to the serial port on the computer.
(If the computer port names are different, then type the computer’s Serial port name into the edit box on the
General tab.) Click OK.
a) Check all hardware connections.
a) Loose hardware connection between computer and field device.
b) You are trying to communicate with a field device that is not supported by the current version of the SCT 3000.
b) None.
Refer to the Readme.txt file supplied with the SCT 3000 application for the latest list of
Honeywell-supported Smart field devices.
Table continued on next page
⇒
38
SCT 3000 Installation and Start-Up Guide Release 4
03/00
8— Troubleshooting - Troubleshooting SCT 3000 Operation
Symptom
Unable to see Input or Output
Calibration tabs when in online mode.
Probable Cause
Calibration not enabled in
Options… dialog box.
Note: Calibraton tabs are not visible when operating in the offline mode. The computer that is running the SCT 3000 application must be connected to a field device to perform calibration. SCT 3000 software is designed to detect an online connection before it displays the Input Calibration and Output Calibration tabs.
FlowAlg, Flow Setup, and
Equation tabs are not visible in the SMV 3000 configuration window.
Expert Configuration not enabled in Options… dialog box
Corrective Action
In the View menu, Select
Options…
Click the General tab. Check the Enable Calibration in the
Customize Options box.
PV Monitor window values not being updated.
Unable to display PV Monitor window or use Flow
Compensation Wizard.
Status Scan not enabled in
Options… dialog box
An application extension file
(*.DLL file) is missing or needs to be updated.
Windows 95a does not include this DLL file.
In the View menu, Select
Options… Click the General tab. Check the Enable Expert
Configuration in the
Customize Options box.
In the View menu, Select
Options…
Click the General tab. Check the Enable Status Scan in the
Status Scan box.
The DLL file is available only with Microsoft Internet
Explorer 4.01 SP1 or in
Windows 95b, Windows 98 or
Windows NT 4.0.
See ATTENTION below.
Release 4
03/00
ATTENTION (For computers with Windows 95a operating systems)
If your computer is running Windows 95a, an application extension file
(*.DLL) is needed so that the SCT 3000 PV Monitor window and flow compensation wizard function properly. Windows 95a does not include this
DLL file, but it is available with Internet Explorer 4.01 SP1. (The DLL file is included with Windows 95b, Windows 98 and Windows NT 4.0.)
To check if you have Windows 95a from the Windows desktop:
Click My Computer
à Control Panel à System, then select the General tab.
If you are running Windows 95a and cannot download or do not have
Microsoft Internet Explorer 4.01, it is recommended that you upgrade to
Windows 95B (OSR2), Windows 98 or Windows NT 4.0.
SCT 3000 Installation and Start-Up Guide
39
8— Troubleshooting - SCT Error Codes
SCT Error Codes
Error code numbers identify a particular error that is displayed in an SCT dialog box, in reference to an invalid action. A text message describes the error or invalid action along with the error code for that particular error type. For example entering a value in a box that is not within the range of acceptable values will display the dialog box:
40
Table 13 lists the possible error codes that may appear with a message displayed in an
SCT dialog box. The error code is used as a key to the table listing that may further define error and suggest a possible action to correct the problem.
Table 13 SCT Error Codes and Descriptions
Error
Number
100
Error Description
101
102
103
104
105
106
General
The transaction failed due to a request that was not valid for the current device configuration.
Invalid Parameter The selected database item (parameter) could not be accessed because it is not valid for the current configuration.
Operation Pending
The transaction failed because another transaction is currently pending.
Out of Range
Invalid Value
No Response
Invalid Response
The entered value is not within the valid range.
The entered value is not a valid floating point number. The acceptable floating point format is
+MANTISSAe+EXPONENT.·
For example> 6, -1.2, 34.5e-4, 6e8.
The attached Smart device did not respond. Make sure that the physical connection is secure.
The attached Smart device did not respond properly since the response was not recognizable.
The message was probably corrupted by external influences.
SCT 3000 Installation and Start-Up Guide Release 4
03/00
Release 4
03/00
8— Troubleshooting - SCT Error Codes
Error
Number
107
108
109
110
111
112
113
114
115
116
Error Description
Illegal operation
Local Mode
Transmitter Busy
Write Protected
Unable to Format
Message
The requested transaction is not supported by the attached Smart device. Make sure that the device version is compatible with the current release of the SCT 3000. See the ReadMe.txt file supplied with the SCT 3000.
The attached Smart device could not process the request because it has been placed in local mode.
No more transactions can be processed until local mode is disabled.
The transaction failed because the attached
Smart device is too heavily loaded and is unable to process communication requests.
The value could not be written because the attached Smart device is write protected. The hardware jumper within the device must be repositioned in order to permit write operations.
The STT250 contains a write protection feature that uses a password key in the transmitter configuration.
Some or all of the information required to format the desired communications message is not available. Make sure that all database items on the configuration tab cards have valid values.
Data Inaccessible The requested data is inaccessible or not available.
Card Not Available
The DE PC card is not present or not functional
Make sure that the card is completely inserted in the PCMCIA slot and that the appropriate drivers have been installed.
Communications
Channel Not
Available
The communications channel is temporarily unavailable.
No Message
Pending
Communications
Type Unknown
A message response is expected but none is available.
The transaction failed because the type of communications (analog or DE) could not be determined
SCT 3000 Installation and Start-Up Guide
41
8— Troubleshooting - SCT Error Codes
Error
Number
117
Error
Communications
Timeout
118
119
120
121
Parameter Not
Ready
Parameter
Unknown
Download Failed
Serial Port is not available
Description
The transaction failed due to an internal timeout.
The error is usually indicative of a condition that will require restarting the host computer.
Data from the requested database item has not yet been uploaded from the attached Smart device.
The database item is valid based upon the current configuration, but its value is unknown (as indicated by a series of question marks -- ?????).
The download operation failed due to a problem with the current configuration or a communications error.
The serial port is not available or is not functional.
Loose hardware connection. Make sure that the physical connection is secure.
42
SCT 3000 Installation and Start-Up Guide Release 4
03/00
8— Troubleshooting - Status Bar Messages
Status Bar Messages
The status bar at the bottom of the SCT 3000 application window contains four boxes on the right side of the bar. The last two boxes contain status of the communications link between the computer and the field device.
Box A Box B
Table 14 describes the messages that are displayed in the boxes.
Table 14 Status Bar Communication Messages
Status Description
Box A – Indicates the status of hardware interface.
CARD OK PC card and SOM hardware detected and is communicating.
SERIALOK
NO CARD
Serial Interface hardware detected and is communicating.
No PC card or serial interface detected.
NO LIM *
BAD CARD
No Line Interface Module detected.
Hardware interface fault.
Box B – Indicates the selected communications mode.
ANALOG Device is communicating in the analog mode.
DE4BYTE
DE6BYTE
Device is communicating digitally (DE mode) in either a 4 byte or 6 byte format.
COM UNKNOWN Indicates that the current view is not online.
* Smartline Option Module only
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
43
8— Troubleshooting - Honeywell’s Technical Assistance Center
Honeywell’s Technical Assistance Center
Technical support options
Honeywell offers various technical support options to help you get the most from the
SCT 3000 application.
ATTENTION
Before contacting Honeywell’s Technical Assistance Center (TAC), first try to resolve any apparent problems by referring to this section, this manual, or the online help system or user manual (if available).
By telephone
You can reach Honeywell’s Technical Assistance Center for technical support by phone during normal business hours.
Honeywell Technical Assistance Center Phone:
1-800-423-9883
You may also seek additional help by contacting the Honeywell distributor who supplied your SCT 3000.
By e-mail
You can also e-mail your technical questions or comments about this product to:
Honeywell Technical Assistance Center e-mail: [email protected]
44
SCT 3000 Installation and Start-Up Guide Release 4
03/00
Appendix A - PC Card Manual Installation and Setup
Appendix A
PC Card Manual Installation and Setup
This appendix contains procedures to manually install and setup the PC card in the computer.
Normally, once the SCT 3000 software and PC card are installed in the computer, the computer is restarted. When the computer is connected to a field device and the SCT
3000 application is started, an online connection is automatically established, (status bar message CARD OK). If an online connection cannot be made, you may need to manually install the PC card and setup the PCMCIA socket (PC card slot) of the computer.
Also see Section 8 – Troubleshooting for additional information.
Use one of these procedures in this appendix only if you are using the Smartline Option
Module as the hardware interface, and:
•
You cannot make an online connection between the computer and the field device upon start up of the SCT 3000 application.
•
The status bar message in the application window displays NO CARD. (The computer does not recognize the PC card.)
Depending on which operating system your computer is using, (Windows 95, Windows
NT or Windows 98), you should use the procedure in either Table 15 or Table 16 to manually install and setup the PC card in your computer.
PC Card installation with Windows 95 and Windows NT
Follow the steps in Table 15 to install and set up the PC Card on a computer that is running Windows 95 or Windows NT operating system.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
45
Appendix A - PC Card Manual Installation and Setup
46
Table 15 PC Card Installation for Computers Operating with Windows 95 or
Windows NT 4.0
Step
1
Action
It is recommended that you close any other applications you have running in
Windows 95 or NT 4.0 as these can increase the time for installing your PC card.
2
Insert the SCT PC card into the PCMCIA socket on the computer. Refer to the figure. (The figure shows a possible location for a PCMCIA card socket on a laptop computer.)
Laptop or
Desktop PC
PCMCIA
Socket
3
4
For Windows 95a or lower
When you insert the SCT card, the opening dialog box will be “New
Hardware Found”.
ATTENTION
If you do not see this dialog box, go to step 8.
PC Card
For Windows 95b (or NT 4.0)
When you insert the SCT card, the opening dialog box will be “New
Hardware Found”.
ATTENTION
If you do not see this dialog box, go to step 8.
Choose “Select from a list of alternate drivers”.
Click “OK”.
Go to step 5.
The “Update Device Driver Wizard” dialog box will appear.
Click “Next >”.
The program will search for drivers for the SCT PC Card. Not finding any, the “Windows was unable to
locate a driver for this device…” dialog box will appear.
Click “Finish”.
Go to step 8.
SCT 3000 Installation and Start-Up Guide Release 4
03/00
Appendix A - PC Card Manual Installation and Setup
Step
5
6
Action
For Windows 95a or lower
The “Select Hardware Type” dialog box will open. Select “Other Devices”
(NOT “Other Detected Devices”) then click “OK”.
For Windows 95b (or NT 4.0)
Still in the “Update Device Driver
Wizard”, select “Other devices”
(NOT Other detected devices) from the list below.
Click “Next >”.
— OR you may see —
Still in the “Update Device Driver
Wizard”, select “Original driver,
(Recommended)”.
Click “Next >”.
For Windows 95a or lower
The “Select Device” dialog box will open. “Unsupported Device” will appear in the field.
Click “OK”.
[if the “SCT Option Module
Properties” dialog box appears, click
“OK”]
Then click “Close” at the “System
Properties” dialog box.
For Windows 95b (or NT 4.0)
Still in the “Update Device Driver
Wizard”, the “Unsupported Device” will appear in the field.
Click “Finish”.
After two beeps (only on some systems), click “Close”, then “Close” again at the “System Properties” dialog box.
7
Restart the computer so that the changes will take effect.
After the computer has been restarted, this procedure is completed.
Go to Section 5 – Start Up and Working Online.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
47
Appendix A - PC Card Manual Installation and Setup
If you DO NOT see the “New Hardware Found” dialog box (in Step 3) proceed as follows:
Step
8
Press the “Start” button.
Action
9
Select: “Settings”,
“Control Panel”,
Double click on “System”.
The “System Properties” dialog box will open.
10
11
12
13
14
Select the “Device Manager” tab card.
Click “Refresh”.
“Other Devices” will appear in the list of devices.
Select “Other Devices” (NOT “Other Detected Devices”).
Select “Honeywell - SCT Option Module” that will appear under “Other
Devices”.
Click “Properties”.
The “Honeywell - SCT Option Module Properties” dialog box will appear.
Windows 95a or lower
Select the “DRIVERS” tab, then click the “CHANGE DRIVER” button.
Windows 95b (or NT 4.0)
Select the “Driver” tab, then click the
“Update Driver. . .” button.
The “Update Device Driver Wizard” dialog box appears.
Select “No, Select Driver from List” then click “Next >”.
Perform steps 5 through 7 to complete the installation procedure.
48
SCT 3000 Installation and Start-Up Guide Release 4
03/00
Appendix A - PC Card Manual Installation and Setup
PC Card installation with Windows 98
Follow the steps in Table 16 to install and set up the PC Card on a computer that is running Windows 98 operating system.
Table 16 PC Card Installation for Computers Operating with Windows 98
Step
1
Action
It is recommended that you close any other applications you have running in
Windows 98 as these can increase the time for installing your PC card.
2
Insert the SCT PC card into the PCMCIA socket on the computer. Refer to the figure. (The figure shows a possible location for a PCMCIA card socket on a laptop computer.)
Laptop or
Desktop PC
PCMCIA
Socket
Release 4
03/00
3
PC Card
When you insert the SCT card, the opening dialog box will be “New
Hardware Found – Windows has detected new hardware and is locating the software for it.”
The “Add New Hardware Wizard” dialog box appears.
ATTENTION
If you do not see “New Hardware Found” or the “Add New Hardware Wizard” dialog boxes, go to Step 12.
4
5
Click “Next >”
Select “Display list of all the drivers . . . you want.”
Click “Next >”.
SCT 3000 Installation and Start-Up Guide
49
Appendix A - PC Card Manual Installation and Setup
Step
6
Action
Scroll down the list in the window and select “Other Devices” (NOT “Other
Detected Devices”)
Click “Next >”.
7
Still in the “Add New Hardware Wizard”, the window displays a list of manufacturers and models.
Click “Next >”.
8
9
10
11
ATTENTION
A warning appears telling you that you are installing a driver that is not written for the SCT PC Card. In Windows 98, the SCT 3000 application directly interfaces to the PC Card, so it does not need a dedicated driver. The driver installed by Windows 98 is a generic driver that allows the SCT application to interface to the PC Card.
Click “Yes” to close the warning box.
Still in the “Add New Hardware Wizard”, the window displays “Window driver file search for the device: Unsupported Device.”
Click “Next >”.
The screen will say, “Windows has finished installing the driver for an unsupported device.
Click “Finish”.
Restart the computer so that the changes will take effect.
After the computer has been restarted, this procedure is completed.
Go to Section 5 – Start Up and Working Online.
50
SCT 3000 Installation and Start-Up Guide Release 4
03/00
Appendix A - PC Card Manual Installation and Setup
If you DO NOT see “New Hardware Found” or the “Add New Hardware Wizard” dialog boxes (as in Step 3), proceed as follows:
Step
12
Press the “Start” button.
Action
13
Select: Settings,
Control Panel,
Double click on “System”.
The “System Properties” dialog box will open.
14
15
16
17
18
Select the “Device Manager” tab card, and then click the “Refresh” button.
“Other Devices” will appear in the list of devices.
Select “Other Devices” (NOT “Other Detected Devices”).
Select “SCT Option Module” that will appear under “Other Devices”.
Click the “Properties” button.
The “SCT Option Module Properties” dialog box will appear.
Select the “Driver” tab, then click the “Update Driver. . .” button.
The “Update Device Driver Wizard” dialog box will appear.
Select “No, Select Driver from List”.
Click “Next >”.
Perform steps 5 through 11 to complete the installation procedure.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
51
Appendix B - SCT 3000 Compatibility
Appendix B
SCT 3000 Compatibility
Some computers running particular Windows operating systems and/or containing particular hardware and software combinations may present interference to the SCT 3000 installation and operation. The known conditions are noted below along with possible solutions. See also Section 8 – Troubleshooting for additional information.
PC Hardware or
Software Application
Softex PC Card
Executive Software that may be pre-installed on some laptop comupters running Windows NT 4.0.
The DACOM Gold Card
PCMCIA Modem installed on a laptop computer and the Softex PC Card
Executive Software
Software is uninstalled.
Computers running
Windows NT 4.0.
Computers running
Windows 95a (or greater).
Condition
Software application does not recognize the SCT 3000
PC Card driver installed by the SCT 3000 setup program.
The DACOM Gold Card
PCMCIA Modem no longer functions and causes additional problems when trying to use Outlook or the modem.
Windows NT 4.0 does not support “hot swapping” of
PCMCIA cards and requires that the PCMCIA card be inserted before powering up the computer.
PCMCIA card support problems when converting the English version of
Windows 95 over to other languages.
Solution
Uninstall the Softex PC Card
Executive Software.
See Softex PC Card Executive
Software below.
Substitute a US Robotics 56K
PCMCIA Modem.
Note: The DACOM Gold Card
PCMCIA Modem is difficult to configure and requires the
Softex PC Card Executive
Software to help the user configure the modem.
Cardware® 6.0 for Windows
NT 4.0 is available from Award
Software/Phoenix Technologies if you require the computer to support “hot swapping” of
PCMCIA cards.
Upgrade your computer to either Windows NT 4.0 or
Windows 98.
Note: If upgrading to Windows
NT 4.0, you must re-install the
SCT 3000 application to add the SCT 3000 PC Card Driver.
52
SCT 3000 Installation and Start-Up Guide Release 4
03/00
Appendix B - SCT 3000 Compatibility
Softex PC Card Executive Software
The Softex PC Card Executive Software, when installed, allows Windows NT 4.0 to support "hot-swapping" of PCMCIA cards. Normally Windows NT 4.0 does not support
"hot-swapping" of PCMCIA cards and requires that the PCMCIA card be inserted before powering up the computer.
To de-install Softex PC Card Executive Software
Using the Control Panel and uninstall the SCT 3000 Software:
1. Use the NT Explorer to find and select the directory
"c:\Program Files\Softex\PCCard32
2. After selecting the directory, select the menu "edit-copy"
3. Select the directory "c:\Program Files\Softex",
4. Select the menu "edit-paste" and paste the contents into a new directory called
"c:\Program Files\Softex\Copy of PCCard32"
5. Select "c:\Program Files\Softex\PCCard32"
6. Select and double click "uninstl.exe" this will uninstall the program and delete the files from "c:\Program Files\Softex\PCCard32" directory.
7. The original setup program files that were in now in the directory you created in step
(4).
8. Allow the laptop or PC to re-boot (if you are not asked if you want to reboot the laptop then manually re-boot the PC).
9. Re-install the SCT 3000 software.
ATTENTION
Note that the SCT 3000 application is not compatible with Norton File Assist.
The SCT 3000 Setup program is coded to detect the presence of Norton File
Assist on the computer and, if present, adds a line to the program to ensure that Norton File Assist does not run with the SCT 3000 application.
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
53
Glossary
Glossary
Term Meaning
Release 4
03/00
Analog (R100/R200)
Protocol
DE (Digitally
Enhanced) Protocol
Download
GUI
Line Interface
Module (LIM)
PC
PC Card
PCMCIA
Smart Field Network
(SFN)
Tag ID
Upload
The Honeywell-proprietary analog communications protocol for Smartline field instruments as defined by the Smart
Field Network (SFN) Specification.
Honeywell-proprietary digital communications protocol for
Smartline field instruments as defined by the Smart Field
Network (SFN) Specification.
Refers to the action of transferring an SCT 3000 configuration database file from the host computer to a connected Smart field device.
Graphical User Interface is a term for the graphical images displayed on the computer screens that are generated to simplify the interpretation and selection of data or actions by the computer user.
A hardware assembly that contains the Physical Layer interface to the communications network. It connects between the PC Card and the communications network.
Personal Computer
Refers to the physical card itself, as defined by the
Personal Computer Memory Card International Association
(PCMCIA).
The Personal Computer Memory Card International
Association standard for credit card-size electronic modules for personal computers. Three standard thicknesses are presently specified, identified as Type I, II and III. PCMCIA cards are an increasingly popular packaging format for modems, network interface cards, solid-state memory, hard drives, etc.
Refers to the Honeywell Smart Field Network (SFN) protocol that defines communication mechanisms for
Honeywell analog and digital field devices.
Refers to an ASCII field used to uniquely identify a field device at a specific customer location
Refers to the action of transferring the field device’s data to an SCT 3000 configuration database window.
SCT 3000 Installation and Start-Up Guide 54
Index
Index
A
Adapter cable, 16
Application window, 25
C
Captive cable, 16
CD ROM drive, 6
CD ROM Installation, 12
Computer specifications, 5
Connecting to a field device, 19
D
Database compare function, 31
Database file
Exisitng, 30
New, 29
Database file management, 29
Diskette Installation, 13
Display specification, 5
F
Field devices supported, 2
Floppy disk drive, 5
Flow Wizard, 4
G
Glossary, 53
H
Hardware installation, 15
Hardware specifications
Serial hardware interface, 9
Smartline Option Module, 8 hazardous locations, 8, 19
Help
Accessing, 33
Help menu, 34
Release 4
03/00
SCT 3000 Installation and Start-Up Guide
I
Installation utility, 11
Interface cable. See also Serial hardware interface
L
Line Interface Module (LIM), 16
M
Maximize and minimize buttons, 25
Menu bar, 25
O
Offline mode, 3
Online help features, 33
Online mode, 3
Operating systems, 3, 5
P
Parameter checking, 30
PC card, 16
PC card installation
Windows 95, 45
Windows 98, 49
Windows NT 4.0, 45
PCMCIA Slot, 6
Pointing device, 5
Ports (I/O for printer and serial hardware interface), 6
Power source, 5
Printing a database document, 30
PV Monitoring, 4
R
RAM requirements, 5
55
Index
S
SCT 3000
Compatible computers, 7
Connections to a field device, 19
Error codes, 40
Hardware, 8
Installation utility, 11
PC specifications, 5
Software compatibility, 7, 52
Toolkit contents, 1
SCT 3000 application installation
3.5” Diskettes, 13
CD ROM, 12
SCT 3000 application program, 19
SCT 3000 banner window, 23
SCT 3000 Setup screen, 13
SCT 3000 software features, 3, 25
Serial hardware interface, 8
Assembly and installation, 17
Connection to a STT150, 21
Description, 17
Smartline Configuration Toolkit, SCT 3000
Description, 1
Smartline Option Module, 8, 15
Connecting to a field device, 20
Description, 15
Hardware assembly, 16
Software installation, 11
Technical Assistance Center, 44
Starting the SCT 3000 application, 22
Status bar, 26, 43
Status bar messages, 43
T
Technical support options, 44
Toolbar, 25, 26
Troubleshooting, 35
Error codes, 40
Troubleshooting tables, 36, 37
W
Working offline, 27, 29
Working online, 19, 27
56
SCT 3000 Installation and Start-Up Guide Release 4
03/00
Fax Transmittal Fax No.:
(602) 313-4842
Reader Comments
To: Automation College
From: Name
Title:
Company:
Address:
City:
Telephone:
State:
Fax:
SCT 3000 , Installation and Start-Up Guide, Release 4, 03/00
Comments:
Date:
Zip:
You may also call 800-822-7673 (available in the 48 contiguous states except Arizona; in Arizona call 602-313-5558), email us at [email protected], or write to:
Honeywell Inc.
Industrial Automation and Control
Automation College
2820 West Kelton Lane
Phoenix, AZ 85053-3028
Knowledge Building Tools
Industrial Automation and Control
Honeywell Inc.
1100 Virginia Drive
Fort Washington, PA 19034
تنزيل