Captron CHT1 Series, CHT1-5 Original Operating Instructions


Add to my manuals
19 Pages

advertisement

Captron CHT1 Series, CHT1-5 Original Operating Instructions | Manualzz

This manual has been written for technicians/installers and operators and should be kept for future reference. Read these operating instructions carefully and make sure that you have fully understood the contents before installing or working with the CHT1.

TIP

Metric and imperial measurements are used in drawings.

Imperial measurements are marked with [ ].

Safety

General safety

All work on electrical systems or operating equipment may only be carried out by a specially qualified electrician according to the applicable electrotechnical regulations.

The safety of the system in which the SENSORswitch is integrated is the responsibility of the operator.

Notes and symbols used

Warning notes in relation to personal injury / material damage are formulated according to the "SAFE” principle. This means they contain information on the type and source of the hazard, potential consequences as well as how to avoid and avert danger. The following hazard classifications apply in the safety notes:

DANGER

Danger designates a hazardous situation, which, if ignored, will lead to death or serious injury. The symbol next to the warning indicates the type and source of the danger.

WARNING

Warning designates a hazardous situation, which, if ignored, may lead to death or serious injury. The symbol next to the warning indicates the type and source of the danger.

CAUTION

Caution designates a hazardous situation, which, if ignored, may lead to injury. The symbol next to the warning indicates the type and source of the danger.

NOTICE

Notice designates a situation, which may cause material damages and impair the product’s function if attention is not paid.

TIP

Tip provides additional useful information about the handling of the product.

Symbol

4

Meaning

Avoiding and adverting danger in the warning note

Symbol

Meaning

Instructions for action

All instructions to be followed within a procedure are always listed in chronological order.

List

WARNING

Improper work on electrical systems!

Electric shock can result in death or life-threatening injuries.

4

Before working on electrical systems, disconnect them from their voltage supply and secure them against being switched on again.

4

Work on electrical installations should be carried out only by qualified personnel in compliance with local and national electrical regulations and specifications.

Personnel qualifications

A qualified electrician is a person with suitable technical training, expertise and experience as well as knowledge of relevant standards, who can evaluate the work assigned to them correspondingly and recognize potential risks.

Intended use

The SENSORswitch is intended for use in accordance with the items listed here, the values from the “Technical specifications” chapter and the product description.

Only connect the product to a limited energy source as per IEC

61010 or an NEC class 2 power supply unit.

Source current < 4 A at maximum operating voltage.

Reasonably foreseeable misuse

The switch is not suitable for:

• use as a safety component in accordance with Machinery

Directive 2006/42/EC.

• use outdoors.

• use in potentially explosive atmospheres.

Technical specifications

Operating voltage

Load current

Output

Output pulse optionally dynamic

CHT12

Reverse polarity protection

Short circuit protection

Voltage drop optionally dynamic

Power consumption

Operating temperature

10…30 V max. 400 mA

PNP-NO

Constant signal when actuated approx. 300 ms

Toggle flip flop

Protection of all cables/lines

Protected against short circuit and overload

Max. 2 V at 400 mA

Max. 2 V at 200 mA

Max. 20 mA at 24 V / Max. 20 mA at 24

V

-30...+70°C

Degree of protection IP

Type of actuation

Actuation force max. altitude

Front IP69K

Capacitive

No actuation force required

2000 m above sea level with "CSA listing"

Max. 95%, non-condensing Relative air humidity

Connections

CHT1-_7_...

200 mm single strands with wire end ferrules

Wire end ferrules with plastic collars DIN 46228

Wire cross-section strands 0.15 mm 2

CHT1-_9_...

Plug M12, 4-pin

CHT1-_9_...

Plug M12, 5-pin

CHT1-_K_...

Terminal strip, 5-pin

CHT1-_5_...

Plug M8, 3-pin

CHT1-_5_...

Plug M8, 4-pin

CHT1-_5_...

Plug M8, 5-pin

Connection plan

PNP-NO, 3-pin

1

4

LED1 LED2

3 brown black

Load blue

+VDC

PNP-NO

0V

PNP-NO, 4-pin

2 white

+VDC / LED1

LED1

LED2

1

4

3 brown black

Load blue

+VDC

PNP-NO

0V

PNP-NO, 5-pin

LED1

LED2

2

5

1

4

3 white grey brown

Load black blue

+VDC / LED1

+VDC / LED2

+VDC

PNP-NO

0V

Dimensional drawing

Example representation plug, M8 4-pin

All dimensions in mm

CHT1-1_9

CHT1-5_9

CHT1-1_8

CHT1-1_8/CPM20

CHT1-6_8

Drilling pattern

General description

The supplied switch can have options that differ from those shown in this manual. This does not affect the function. The CHT1 is equipped with two different colored LEDs. The LEDs are actuated differently depending on the pin configuration.

Assembly

Requirements: Mounting surface is level and clean.

► Disconnect the system from its voltage supply and secure it against being switched on again.

► Set the desired position of the

SENSORswitch and drill the hole according to the drilling pattern.

► Unscrew the lock nuts (B) from the

SENSORswitch (A).

► Insert the SENSORswitch into the prepared hole and screw the lock nuts

(B) back on.

► Position the SENSORSwitch (A) and tighten the lock nuts with max. 1 Nm.

► Connect the SENSORswitch (A) electrically according to the connection plan.

Maintenance

Carry out the following maintenance operations at the specified intervals.

Operation

Clean the switch surface

Check cable for integrity

Check screw connection for tightness as needed

X annually

X

X

NOTICE

Solvents contained in cleaning agents can attack the plastic of the button!

4

Clean the surface of the button with a neutral cleaning agent or a damp microfiber cloth.

Disassembly

► Disconnect the system from its voltage supply and secure it against being switched on again.

► Disconnect the electrical connection and remove the lock nuts.

Disposal

Different types of electrical and electronic components must be recycled according to their type. All applicable statutory, state and local laws and regulations must be complied with.

Manual updates

CAPTRON reserves the right to make changes to the contents of this manual as needed. The most current version can be found on our website www.captron.com

.

Imprint

The operating instructions have been authored and published by

CAPTRON Electronic GmbH

Johann-G.-Gutenberg-Straße 7

82140 Olching – Germany

Tel.: +49 (0)8142 - 44 88 - 160 [email protected]

www.captron.com

Copyright 2020

CHT1 ohne Relais 1.4

Product description

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • - Capacitive actuation requires no contact force, allowing for precise and hygienic operation.
  • - Customizable output options provide flexibility for different applications.
  • - Reverse polarity protection and short circuit protection ensure safe and reliable operation.
  • - LED indicators provide visual feedback on the switch status.
  • - Compact size and rugged construction make it suitable for space-constrained applications.
  • - IP69K protection rating ensures durability in harsh environments.

Related manuals

Frequently Answers and Questions

What is the operating voltage range of the CHT1-5?
The CHT1-5 operates within a voltage range of 10 to 30 volts.
What type of output does the CHT1-5 provide?
The CHT1-5 offers a PNP-NO (positive-negative-normally open) output type.
Is the CHT1-5 suitable for outdoor use?
No, the CHT1-5 is not intended for outdoor use.
What is the maximum load current that the CHT1-5 can handle?
The CHT1-5 can handle a maximum load current of 400 milliamperes.
What is the degree of protection for the CHT1-5?
The CHT1-5 has an IP69K protection rating, indicating its resistance to dust and high-pressure water jets.