Residential Solar Electric

& Storage Tanks

Solaraide

®

HE tanks are available as electric backup water heaters and as storage tanks, designed for use with closed loop solar water heating systems

Features & Benefits

• Double wall heat exchanger includes copper tubing wrapped around the tank and secured within the jacket for positive leak protection

• Two well insulated models to choose from…a storage tank or a high

efficiency 4500 Watt backup electric water heater

• Electric backup model provides at least 40 gallons of stored hot water

Easy Installation and

Maintenance

• Collector feed and return fittings conveniently located on front of tank for easy installation

• A special 1/2" NPT opening is provided for installation of a “probe type” thermostat

• Durable brass drain valve for easy maintenance

Tank Design & Construction

• Cold water inlet brings cold water to tank bottom to prevent mixing with heated water

• Rheemglas ® tank lining resists

corrosion and prolongs tank life

• Anode rod equalizes aggressive action for prolonged tank life

• Temperature and pressure relief valve included

• Electric backup model has automatic temperature control and over heat protection

• Low lead compliant

Warranty

• 6-Year limited tank and parts

warranty*

* See Residential Warranty Certificate for complete information

Solaraide HE Tanks

65, 80 and 120-Gallon Capacities

Heat Exchanger

Electric Water Heaters and

Storage Tanks

Copper Heat Exchanger Coil

Type L Copper 5/8" I.D.

SOLARAIDE

TANK CAPACITY

65 Gallons

80 Gallons

120 Gallons

COIL CAPACITY

GALLONS

2.2

2.2

2.6

LENGTH OF TUBING

AROUND TANK (FT)

120

120

143

8"

RELIEF

HOT VALVE COLD

B

COLD

INLET

WATER CONNECTION NIPPLES

ALL 3/4" N.P.T.

COLLECTOR

RETURN

PRESSURE DROP THROUGH COIL (FEET OF H

2

0)

FLOW RATE

HEAD LOSS (FEET)

65 & 80-GALLON 120-GALLON

1 GPM

2 GPM

3 GPM

1.3

4.8

10.0

1.6

5.7

12.0

PROBE

PORT

A

COLLECTOR

FEED

7"

WATER CIRCULATOR

(REQUIRED FOR NON-

GRAVITY SYSTEMS)

SOLA

R

R

COLLECTO

SUITABLE FOR

R

POTABLE WATE

AND PROPYLENE

GYLCOL

SOLUTION

DESCRIPTION

T

Y

P GAL. MODEL

E CAP. NUMBER

Tall 65 82V65HE

Tall 80 81V80HE-1

Tall 80 81V80HE-T

Tall 120 82V120HE-1

Tall 120 82V120HE-T

ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.

ELEMENT

WATTAGE

UPPER

HEIGHT

A

APPROX

DIAMETER

B

SHIP WT.

(LBS)

APPROX.

R-FACTOR

4500 W*

4500 W*

Storage only

4500 W*

Storage only

59

58-3/4

58-3/4

62

62

21

24-1/2

24-1/2

28-1/4

28-1/4

170

222

222

380

380

R-17.3

R-17.3

R-17.3

R-17.3

R-17.3

*Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring and 4500 watt heating element.

If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested. To prevent corrosion, proper pH levels in transfer fluid must be maintained. Solaraide models meet all current state requirements for solar storage tanks. The tanks are Rheemglas lined and are designed to operate up to 150 PSI.

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100

Roswell, Georgia 30076 • www.rheem.com

Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1

Brampton, Ontario L6Y 0P5 • www.rheem.ca

PRINTED IN U.S.A. 12/20 WP FORM NO. 101-16 Rev. 21

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement