BFT CAPRI Instruction Manual
BFT Capri is a control unit designed for tubular motors controlling roller shutters and sunblinds. It features centralized wire control with up to 8 zones, radio control compatibility via TRC series transmitters, and the ability to connect accessories like anemometers, twilight sensors, solar cells, and safety devices.
विज्ञापन
विज्ञापन
CAPRI
D811282 26-03-02 Vers. 03
CONTROL UNIT
Thank you for buying this product, our company is sure that you will be more than satisfied with the performance of the product.
Read the “ Instruction Manual ” supplied with this product carefully, as it provides important information about safety, installation, operation and maintenance. This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives: 89/336/EEC (amended by RL 91/263/EEC,
92/31/EEC and 93/68/EEC), 73/23/EEC, 99/5/EEC.
1) GENERAL OUTLINE
Capri is a control unit especially designed for tubular motors controlling roller shutters and sunblinds and is compatible with the EElink protocol. It is available in the CAPRI and CAPRI RIC versions. Besides the functions of mod. CAPRI , the control unit mod. CAPRI RIC provides the radio control by means of the transmitters of the TRC series. Both models can be equipped with additional attachments such as anemometers, twilight sensors, solar cells and opening, closing and stop buttons. Furthermore, it is possible to connect special safety devices when necessary.
The commands can also be sent by radio by means of a transmitter of the rolling code series. Memorization on the transmitters is obtained based on the self-learning method. The unit provides a centralized wire control system that can be subdivided into 8 or more zones regardless of the wiring.
2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or things.
• The “ Warnings ” leaflet and “ Instruction booklet ” supplied with this product should be read carefully as they provide important information about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon or polystyrene bags out of children’s reach.
• Keep the instructions together with the technical brochure for future reference.
• This product was exclusively designed and manufactured for the use specified in the present documentation. Any other use not specified in this documentation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences resulting from improper use of the product, or use which is different from that expected and specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures (door, gates etc.), as well as from any deformation which might occur during use.
• The installation must comply with the provisions set out by the following
European Directives: 89/336/EEC, 73/23/EEC, 98/37/ECC and subsequent amendments.
• Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any buffer batteries, if fitted.
• Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance equal to or greater than 3mm.
• Check that a differential switch with a 0.03A threshold is fitted just before the power supply mains.
• Check that earthing is carried out correctly: connect all metal parts for closure (doors, gates etc.) and all system components provided with an earth terminal.
• The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers’ components are used.
• Only use original parts for any maintenance or repair operation.
• Do not modify the automation components, unless explicitly authorised by the company.
• Instruct the product user about the control systems provided and the manual opening operation in case of emergency.
• Do not allow persons or children to remain in the automation operation area.
• Keep radio control or other control devices out of children’s reach, in order to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on the automation system, and always request the assistance of qualified personnel.
• Anything which is not expressly provided for in the present instructions, is not allowed.
3) TECHINCAL SPECIFICATIONS
Mains power supply: .................................................. 230Vac
±
10%, 50Hz
Motor current: ......................................................................................... 2A
Motor power: ......................................................................................350W
Number of storable radio-controls: ........................................................ 64
Reception frequency (CAPRI RIC only): ................................. 433.92MHz
Current for external attachments: .................................................... 70mA
Number of zones with wire control (master): ................................ 8 or 127
Max. connection length: .................................................................... 250m
Protection degree of case: ............................................................. IP20 (*)
Dimensions: ............................................................................. see figure 1
Weight: .................................................................................... 350g approx
(*) The protection degree of the enclosure is brought to IP55 by applying a special accessory supplied on request. Only use fittings suited to the container dimensions and cable diameter.
4) INSTALLATION
The unit is usually installed inside the shutter box as shown in figure 2; in case of blinds, the unit should possibly be installed in a dry and sheltered place. Always choose a position, which grants access to the shutter or blind when these are completely rolled up or unrolled. When selecting the installation position, also consider the availability of a connector block in the electric installation or the possibility of installing visible or hidden pipes.
Make some openings in which to pass the cables and use the cable-holders or the PG9 joints supplied depending on the protection degree to be reached with the case, and based on the installation conditions.
Fasten the support (fig.3) marking the two holes by using the two slots provided on the container as a template. Use the screws supplied directly or make a 4mm hole to insert the anchors supplied depending on the material the support is made of. Tighten the screws completely and correct any centering difference using the slots on the container.
NOTE: when drilling or tightening the screws, be careful not to damage the ducts or the cables underneath.
The sensors must be installed so as they can detect the operating conditions of the corresponding devices: the anemometer should be place in a position where the conditions are the same as for the shade and the twilight sensor should be place in a sufficiently lit position.
5) ELECTRICAL CONNECTIONS
CAUTION: The electrical connections must be workmanlike performed only by qualified and specialized technicians who also have to observe any current directives and use suitable materials.
A knife switch must be installed before the appliance, with an opening distance between the contacts equal to or greater than 3 mm, with magnetothermal and differential protection having a capacity suited to the consumption of the appliance.
Only use cables in compliance with harmonized or national standards for wiring, with a section appropriate for the protections located upstream, the consumption and the installation conditions.
Connect the accessories, safety and control devices to the motor unit, making sure that the mains voltage connections are kept totally separate from the low voltage accessory connections. Make reference to figure 4 for the single system connection or to figure 5 for the connection of the units of a centralized system.
To ensure continuity of the ground protection circuit, connect the earth wire of the operator to the earth wire of the power supply unit using the terminal supplied. The serial connections to obtain a centralized wire control must only be made using telephone-type pair. When using a telephone wire with several pairs it is necessary to use the wires of the same pair. The length of the telephone wire between the units must not exceed 250m. The control push-buttons should be provided with symbols indicating the actual operation direction (fig.6).
If other devices have to be connected onto the STOP and PHOTOCELL terminals, it is necessary to remove the jumpers connected by the manufacturer. When connecting several devices to one of these inputs, they must be connected in series.
6) WIRE CONTROL
To obtain a local wire control, it is sufficient to connect the inputs of the board according to the instructions given in paragraph 4 and fig.4.
If a centralized wire control has to be obtained, it is necessary to carry out the connections of fig.5 following the instructions given in paragraph 4 in addition to the connections described above. Furthermore, it is necessary to identify the master board and set the zone addresses. The master board is the one in which all the controls are carried out by all the other boards belonging to the same zone. To configurate the board as a master board, move the DIP switch 5 to “ON”. Only one master board can be identified in each zone. The zone includes all the boards with the same address; the address is set by mean of the three DIP switches n
°
6, 7, 8.
Therefore, it is possible to define up to 8 different zones regardless of the wiring.
A master device having the zone configuration set to value 0 controls all the
373
374 other connected devices (overall control), regardless of their configuration
(master or slave).If a system requires more than 8 zones, it is possible to define different addresses from 8 to 127 using the UNIPRO universal programmer and setting the number of the zone in the advanced parameter
“ Address 1 ”. In this case, the address programmed using the UNIPRO will prevail over the one programmed using the DIP switches. To return to the configuration function using the dip switches, set the advanced parameter
“ Address 1 ” to 0, using the UNIPRO , or erase the memory completely as described below (in this case all information stored in the board will be erased). A centralized wire system can be created both by closing the loop
(carrying out the connections marked with a broken line in fig.5 and setting to ON the dip switch n
°
4 of the master boards), or by leaving the loop open
(without carrying out the connections marked with a broken line in fig.5 and leaving on OFF the dip switch n
°
4 of all boards).
When the loop is closed, each zone master checks the execution of the commands by the slave boards and updates a part of the statistics relating to the loop composition. The unsuccessful commands will be repeated after a few minutes. When the loop is open, these operations are not possible while all the other functions remain unaltered. The panels preset for radio control can also be connected via wire. In this case, and when they are defined as master, or overall control master devices, only the centralised radio controls related to the T2, T3 and T4 keys (stop, open and close) are sent via cable, whereas the T1 key (four-step logic) operates locally and is not sent via cable.
NOTE: The maximum number of devices, including master and slave types, which can be connected to an individual network, is equal to 255, consequently a master panel can control up to a maximum of 254 slave panels.
In the case of installations with a high number of slave panels, the transmission delay of a command sent by the master to the subsequent slave device is about 0.5s. Therefore, to give an example, the 50th slave panel on the line will have a delay in executing the command of about 25s with respect to the master panel.
7) ANEMOMETER CONFIGURATION
The anemometer can be connected as described in paragraph 4 (fig.4) to obtain the automatic closure when the wind speed is greater than a certain preset threshold. The threshold causing the anemometer to step in is set by using the DIP switches n
°
1 and 2. The table given below shows the approximate speed of the wind corresponding to the threshold relating to the accessory P111182 (anemometer performing 2 impulses per revolution):
Dip n
°
1
OFF
OFF
ON
ON
Dip n
°
2
OFF
ON
OFF
ON
Threshold Hz
11,5
23
35
47 m/s
4,2
8,4
12,6
16,8 km/h
15
30
45
60
The control of the anemometer on the master board acts in a centralized way, while the controls of the anemometer on the slave boards act locally.
8) TWILIGHT SWITCH
It is possible to connect a twilight switch (see paragraph and fig.4).
The closure of the twilight switch contact originates a closing command in the actuator. When the contact re-opens, it originates an opening command in the actuator. The twilight control of the master board acts in a centralized way, while the twilight commands of the slave boards only act locally.
9) SAFETY DEVICE
In case of automatic or semi-automatic control, it is possible to connect a safety device (see paragraph and fig.4) as may be prescribed by the safety standards. The opening of the contact during the closing phase originates an opening command. Such a command only acts locally.
The safety device can be supplied with 24Vac power from the terminals 19 and 20 (max 70mA).
10) HOLD-TO-RUN CONTROLS
By setting to ON the dip Switch n
°
3 the input controls of the board become hold-to-run controls. In this case, the functions of the receiver and external sensors are inhibited. In case of a centralized wire system, the command originated by the serial network are not processed.
11) RADIO CONTROL (FOR MOD. CAPRI RIC ONLY)
The radio-controls combined with the CAPRI RIC control board, can feature 1, 2 or 4 keys. The functions of each key are the following:
Key 1: local control with 4-step logic (the first impulse opens, the second impulse stops on opening, the third impulse closes, the fourth stops on closing).
Key 2: local and zone stop control.
Key 3: local and zone opening control.
Key 4: local and zone closing control.
11.1) MANUAL PROGRAMMING OF RECEIVER
For receiver programming, press the key S1 located on the Capri board, the
LED DL1 will flash with a frequency of 2Hz to confirm that the transmitters are operating in the self-learning mode. Press the key hidden by the transmitters with 1 or 2 keys (see fig.8) within 10 seconds or jump the 4-key transmitters (see fig.8). The LED DL1 will stay on permanently. Press the correct key of the transmitter within 10 seconds. When selecting the key, bear in mind that if the key 1 is pressed after pressing the hidden key, all the keys of the transmitter are stored in the receiver. If the key 2 is pressed, the keys 2, 3, 4 will be stored. If the keys of the transmitters are stored correctly on the different receivers, a centralized system can be obtained without connecting the control boards to one another. To this purpose, use single-channel or double-channel transmitters for local commands or fourchannel transmitters for centralized commands. An example is given in figure 7: the TX1 has been stored using the key 1 on the CAPRI 1 control unit and using the key 2 on the CAPRI 2 and CAPRI 3 control units.
Furthermore, the transmitter TX2 has been stored in CAPRI 2 control unit using the key 1 while the transmitter TX3 has been stored in the CAPRI 3 control unit always using the key T1. Under these circumstances, the key
T1 of the transmitter TX1 will control the motor M1 based on the 4-step logic
M1 (local control) and the keys T2,T3 and T4 of the transmitter TX1 will control stopping, opening and closing of all the 3 motors respectively
(centralized control). The transmitters TX2 and TX3 , on the other hand, perform a local command with 4-step logic onto M2 and M3 respectively.
By repeating the method, it is possible to perform the centralized control of several zones with great flexibility as far as activation and subdivision are concerned. Obviously, with this type of centralized control, the commands sent by wire (opening, closing, stop, photocell, twilight sensor, anemometer metro) will only be of local nature.
11.2) RADIO PROGRAMMING OF RECEIVER
After manual programming of the first radio-control, it is possible to perform a radio programming (without having to operate on the control unit again).
To start this programming mode, press the hidden key of a transmitter already programmed and then press a key on the same transmitter within
10 seconds. In this way, the transmitter operated by the control unit will switch to self-learning mode and it will be possible to execute all the steps described for the manual programming of the receiver.
11.3) PROGRAMMING OF THE RECEIVER USING THE EELINK PROTOCOL
The receiver can also be programmed using the EElink protocol, connecting the UNIPRO terminal by means of the UNIFLAT and UNIDA accessories.
Before connecting the UNIDA accessory to the board, remove the jumper
J1 . Upon completion of cancellation, remember to reposition the jumper J1 on pin 1 and 2 of the connector JP3 , otherwise the parameters stored in the board will not be protected from accidental overwriting. The arrangement of the connections is shown in fig. 8. When programming the receiver make reference to the instructions for the UNIPRO terminal. Up to 64 radiocontrols can be stored and the control unit can control both standard and personalized radio-controls. As far as the arrangement of the outputs is concerned, the control unit CAPRI acts as a 4-channel receiver in which the outputs have the following functions regardless of the mode programmed:
Output 1: local control with 4-step logic (the first impulse opens, the second impulse stops on opening, the third impulse closes, the fourth stops on closing).
Output 2: local and zone stop control.
Output 3: local and zone opening control.
Output 4: local and zone closing control.
The control unit CAPRI does not supply power to the programming terminal. For transmitter personalization, use the UNITRC and UNIFLAT accessories and follow the instructions supplied with the programmer.
Note: the personalization of a transmitter acts in an irreversible way on the code stored therein. The personalized code can be changed but the transmitter cannot be configurated as standard again.
12) ERASURE OF STORAGE
To erase the storage of the board, move the jumper J1 on pin 2 and 3 of connector JP3, press the key S1 for 10 seconds. The LED DL1 flashes with a frequency of 5Hz and then stays on permanently for a few seconds until the storage has been erased. This operation will erase all data from the board memory, and its configuration will be the same as the original one set by the manufacturer. Upon completion of cancellation, remember to
reposition the jumper J1 on pin 1 and 2 of the connector JP3 otherwise the parameters stored in the board will not be protected from accidental overwriting.
13) STATISTICS
By connecting a programmer compatible with the EElink protocol it is possible to read some statistical parameters of the system such as:
Board version: indicates the name and version of the board.
List description: indicates the description assigned to the system.
This description can be inserted or modified by means of the UNIPRO terminal.
Number of manoeuvres: indicates the number of manoeuvres that the board has performed since its installation.
Number of manoeuvres since maintenance: indicates the number of manoeuvres performed since last maintenance operation, including any configuration operation of the board and self-diagnosis.
Maintenance date: indicates the date of the last maintenance operation performed.
Maintenance updating: allows the number of manoeuvres to be updated since last maintenance operation.
Zone executors (advanced statistics) “Address16”: indicates the number of the actuators belonging to the same master zone (it is updated by the master boards only).
Total executors “Configuration 17”: indicates the total quantity of the actuators connected (it is updated by the master boards only).
14) SELF-DIAGNOSIS
The board features a luminous diode DL1 which indicates the current state according to the table given below:
On Leds
DL1 Off or On for more than 10s
DL1 On for less than 10s
DL1 1Hz flashing
DL1 2Hz flashing
DL1 5Hz flashing
DL1 10Hz flashing
Diagnosis
Microprocessor fault.
Key in stand-by for storage of a radio-control or erasure of storage.
Active board in stand-by or command execution.
Activation of code storage
Activation of total storage erasure.
Transmitter reception in course.
Besides the signals given by the LED, the CAPRI board provides the selfdiagnosis functions offered by the EElink protocol. When performing the self-diagnosis by means of the UNIPRO terminal it is possible to obtain a diagnostic message identifying the active inputs, that is the ones in a state different from the stand-by position.
The stand-by position is defined as a condition in which no control signals are active and no safety devices have stepped in.
15) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified personnel regularly.
The materials making up the set and its packing must be disposed of according to the regulations in force.
Batteries must be properly disposed of.
16) SUMMARY OF DIP-SWITCH FUNCTIONS
The control unit comprises 8 dip-switches, which allow to select the operation modes according to the table given below: n
°
DIP Description
1,2 Anemometer See paragraph 6
3 Hold-to-run control ON: The opening and closing controls are hold-to-run type and only local. The operation of the serial unit and the radio functions receiver are not included.
OFF: The opening and closing controls are semi-automatic and all configurated are operative.
4
5
Open/closed loop
(for master boards only, leave Off for slave boards)
Master / Slave
ON: The connections marked with a broken line in fig.5 have been made, the advanced statistics are being managed.
OFF: The connections marked with a broken line in fig.5 have not been made, the advanced statistics are not being managed.
ON: The board sends global and zone commands to the telephone pair
6,7,8 Zone address
0,0,0
0,0,1
0,1,0
0,1,1
1,0,0
1,0,1
1,1,0
1,1,1
OFF: The board performs the global and zone commands received by the telephone pair.
0=OFF, 1=ON
All system
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
The descriptions and illustrations contained in the present manual are not binding. The Company reserves the right to make any alterations deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product features unchanged, at any time and without undertaking to update the present publication.
375
376
147
110
34
Fig. 1
S1
DL1
JP3
U4
Fig. 2
Fig. 3
I
DIP-SWITCH
1,2 ANEMOMETRO
3
4
5
COMANDO UOMO PRESENTE
ANELLO APERTO/ANELLO CHIUSO
MASTER/SLAVE
6,7,8 INDIRIZZO AREA
GB
1,2 ANEMOMETER
3
4
5
HOLD-TO-RUN CONTROL
OPEN LOOP/CLOSED LOOP
MASTER/SLAVE
6,7,8 AREA ADDRESS
F
4
5
1,2 ANMOMéTRE
3 COMMANDE A ACTION
MAINTENUE
BOUCLE OUVERTE/FERME
MASTER/SLAVE
6,7,8 ADRESSE DE ZONE
D
1,2 ANEMOMETER
3
4
5
TOTMANNSTEUERUNG
SCHLEIFE OFFEN/
SCHLEIFE GESCHLOSSEN
MASTER/SLAVE
6,7,8 ZONENADRESSE
E
1,2 ANEMîMETRO
3
4
5
HOMBRE PRESENTE
ANILLO ABIERTO/CERRADO
MASTER/SLAVE
6,7,8 DIRECCIîN çREA
P
1,2 ANEMîMETRO
3
4
5
HOMEM PRESENTE
ANEL ABERTO/ANEL FECHADO
MASTER/SLAVE
6,7,8 ENDEREO çREA
U4
8 7 6 5 4 3 2 1
T1
K2
RV1
F1 JP1
N
1 2 3 4 5
230
V~
L
M
C
C4
C2
R1
C1
C3
Fig. 4
DL1
JP4
U5
S1
MD1
JP3
C7
CAPRI
K1 C39
C38
U7
JP2
SHIELD
ANT
COM
PHOT
STOP
CLOSE
OPEN
COM
Rx
Tx
24V~
Fig. 5
CREPUSCOLARE
TWILIGHT SENSOR
CREPUSCULAIRE
DMMERUNGSSENSOR
CREPUSCULAR
CREPUSCULAR
ANENOMETRO
ANENOMETER
ANENOMETRE
ANEMOMETER
ANEMOMETRO
ANEMîMETRO
JP2
20-21 ANTENNA ANTENNA
ANTENNE ANTENNE
ANTENA ANTENA
18-19 ALIMENTATORE
ACCESSORI
POWER SUPPLY
FORACCESSORIES
ALIMENTATEUR
ACCESSOIRES
STROMVERSORGUNG
ZUBEH R
ALIMENTADOR
ACCESORIOS
ALIMENTADOR
ACESSîRIOS
15-17 CREPUSCOLARE
TWILIGHT SENSOR
CREPUSCULAIRE
DMMERUNGSSENSOR
CREPUSCULAR
CREPUSCULAR
15-16 ANENOMETRO
ANENOMETER
ANENOMETRE
ANEMOMETER
ËNEMOMETRO
ANEMîMETRO
Max. 250m
Fig. 5
6 7 8 9 6 7 8 9 6 7 8 9 6 7 8 9
377
230 Vac 230 Vac 230 Vac 230 Vac
Fig. 6
378
Fig. 7
M1
CAPRI 1
5
JP1
4 3
L
230
Vac
N
2 1
JP2
T3
T4
T1
T2
TRC4
TX1
M2
CAPRI 2
5
JP1
4 3
L
230
Vac
N
2 1
JP2
T3
T4
T1
T2
TRC4
TX2
Fig. 8
M3
CAPRI 3
5
JP1
4 3
L
230
Vac
N
2 1
JP2
T3
T4
T1
T2
TRC4
TX3
J1
CAPRI
UNIFLAT
UNIDA
UNIPRO
CONNETTORE JP3 ¥ CONNECTOR JP3
CONNECTEUR JP3 ¥ STECKVERBINDER JP3
CONECTOR JP3 ¥ CONECTOR JP3
UNIFLAT
CONTATTI ¥ CONTACTS
CONTACTS ¥ KONTAKTE
CONTACTOS ¥ CONTACTOS
UNITRC
UNIFLAT
TRC1-2-4
UNITRC
CONTATTI ¥ CONTACTS
CONTACTS ¥ KONTAKTE
CONTACTOS ¥ CONTACTOS
डाउनलोड
विज्ञापन