Model 1092/1093 Program ROM Update

1 Introduction

This document provides instruction to replace the program ROM (firmware) in the Model 1092A/B/C and Model 1093A/B/C series GPS Satellite Controlled Clocks. Basic understanding of electrical safety and static protection is expected.

2 Required Equipment

1. Torx T-25 or large flat-blade screw driver

2. IC Removal Tool, curved tweezers or small blade screwdriver

3 Saving Original Configuration

Updating the firmware will erase the clock’s configuration. Document the existing settings for reference.

1. 1092B and 1093B/C: press SETUP and sequentially scroll through the various menus.

2. Press ENTER on any menu to sequence through that menu’s settings.

3. 1092A and 1093A: unfortunately, many settings cannot be queried. Use the Operation Manual for a list of serial commands to set local offset, Daylight Saving Time, broadcast modes, IRIG-B time and control functions, etc.

4 Disassembly

1. Disconnect power.

2. Remove from service.

3. Remove the four screws securing the cover with a T-25 driver (or flat-blade screwdriver).

4. Lift off the cover.

5 Installing the Program ROM

1. The program ROM is located at U2 (see Figure 1 on page 4).

2. Remove the old program ROM using the appropriate IC removal tool.

3. Install the new ROM.

Observe the correct IC orientation and make sure the IC pins line up well on both sides of the socket. If necessary, use a pin-bending tool to line up the pins.

4. Option 28: If present, the Power System Time, Frequency, and Phase Monitor may also require an update ROM. Follow the separate instructions for the update steps.

6 Reassembly

1. Replace the cover.

2. Install the four screws securing the cover with a T-25 driver (or flat-blade screwdriver).

3. Place into service.

4. Connect the power.

5. Set to factory defaults.

7 Configuration

7.1

Factory Defaults

7.1.1

Front Panel (B and C Models)

1. Press and release SETUP at startup and during the first two splash screens.

If not displayed then start over.

2. Display will show SET FACTORY DEFAULTS?

3. Press ENTER and follow the on-screen prompts.

Arbiter Systems, Inc.

Fax: +1.805.238.5717

· 1324 Vendels Circle, Suite 121 · Paso Robles, CA 93446 · USA · Tel: +1.805.237.3831

· E-mail: [email protected]

· Internet: http://www.arbiter.com

PD0030600I

1

Model 1092/1093 Program ROM Update

7.1.2

Serial

1. Connect a null-modem cable between a computer and the main serial port on the clock.

2. Open a terminal program (e.g. PuTTY) with port settings of 9600, 8, N, 1.

3. Type into terminal: 1092XX

7.2

Model Select

1. Type in the serial command listed below according to your clock model.

Model Serial Command Model Serial Command

1092A 0,1,1092XZ 1093A 3,1,1093XZ

1092B

1092C

1,1,1092XZ

2,1,1092XZ

1093B

1093C

4,1,1093XZ

5,1,1093XZ

2. Verify model configuration by cycling power and watching LCD display. If Model is incorrect then retype the Model Select command.

7.3

Option Setup

7.3.1

Front Panel

1. Press SETUP to enter the configuration menus.

2. Press UP, DOWN, and ENTER to navigate the menus and configuration selections.

3. Press any top row button to exit the configuration menus.

4.

NOTE: Cycle power to make sure the main processor and the option are communicating.

7.3.2

Serial

Command Description

M,N,K,LXI Where:

M = Option Location (0 = Main Board, 1 = Aux Board)

N = Option Number

Option Code (N = ) 0 1 2

Main Board Option (M = 0) none 19 –

3

4

5

6

7

8

9

Aux. Board Option (M = 1) none 03 20A 27 28 29 32 33 34 35

K = security tree (model number, e.g. 1092 or 1093)

L = (use only if N selects Option 28) L = 0 for 60 Hz; L = 1 for 50 Hz

Example: 1,8,1093XI Model 1093A/B/C with Option 34

Example: 1,4,1093,0XI Model 1093A/B/C with Option 28 and 60 Hz reference

NOTE: Cycle power to make sure the main processor and the option are communicating.

2

Arbiter Systems, Inc.

· 1324 Vendels Circle, Suite 121 · Paso Robles, CA 93446 · USA · Tel: +1.805.237.3831

Fax: +1.805.238.5717

· E-mail: [email protected]

· Internet: http://www.arbiter.com

Model 1092/1093 Program ROM Update

7.4

Typical Configuration List

Function

Local Offset

Command Description

±

hh:[mm]L Where: hh = Hour mm = Minute (15 minute increments)

Out-of-Lock Delay

IRIG-B Data - Time Offset

IRIG-B Data - IEEE 1344

Daylight Saving Time Mode

Daylight Saving Time Start

[-]nK

Example: -8L Pacific Time Zone

Where:

- = disabled n = delay in minutes (0 to 99)

Example: -1K Disabled

IL

IU

I0

I1

1,mDT

Example: 10K 10 Minute Delay

Set to local time code reference.

Set to UTC time code reference.

Set IEEE 1344 extension Off.

Set IEEE 1344 extension On.

Set how Daylight Saving Time operates.

Where: m = mode (0 = Off, 1 = On, 2 = Auto)

Example: 1,2DT Automatically adjust for DST per configuration.

2,w,x,y,zDT Set Daylight Saving Time start time.

Daylight Saving Time Stop

Daylight Saving Time Review

Where: w = month (0 = JAN, 11 = DEC) x = week of month (0 = First, 1 = Second,

2 = Third, 3 = Last, 4 = Second from Last,

5 = 3rd from Last) y = day of week (0 = SUN, 6 = SAT) z = minutes after midnight (0 to 1440)

Example: 2,2,1,0,120DT DST begins at 2:00 am on the second Sunday of March.

2,w,x,y,zDT Set Daylight Saving Time stop time.

0DT

Where: w = month (0 = JAN, 11 = DEC) x = week of month (0 = First, 1 = Second,

2 = Third, 3 = Last, 4 = Second from Last,

5 = 3rd from Last) y = day of week (0 = SUN, 6 = SAT) z = minutes after midnight (0 to 1440)

Example: 3,10,0,0,120DT DST ends at 2:00 am on the first Sunday of November.

Return Daylight Saving Time Configuration.

Arbiter Systems, Inc.

Fax: +1.805.238.5717

· 1324 Vendels Circle, Suite 121 · Paso Robles, CA 93446 · USA · Tel: +1.805.237.3831

· E-mail: [email protected]

· Internet: http://www.arbiter.com

3

Model 1092/1093 Program ROM Update

Program ROM

Location

J7B J6 J4 J5 J7

L1

C45

U25 B

A

JMP6

CR4

R20 Q6

JMP2

A

B

CR1 C8

+

R14

JMP1

A

B

CR3

Q5

R19

R*

Q4

DRILL VIA BEFORE

INSTALLING

U28

CR6

C17

C19 C18 C20

U10

U18

C35

+

TP1

+5V

C41

C42

+

+

TP2

GND

C36

C38

C37

+

+

C39

C49

+

+

C34

C33

C43

C40

+

A

B

Y2

C46

C47

CR7

L2

R41

R36

JMP7

U29

C44

+

SERIAL NUMBER

CR8

L3

TP3

+12V

TP4

-12V

1092/1093

PROCESSOR/CONTROLLER

PART NUMBER

LB00189

TAB

REV.

R15

U20

U24 JMP4

U8

VIA

BEFORE

DRILL

INSTALLING

U1

U19

Y1

CR9

R40

CR10

C2

C1 R22

C7

U17

C9

U7 U6

Q2 Q1

VIA

BEFORE

DRILL

INSTALLING

R13

C5

R11

R10

JMP3

R1

U5

C10

U4

R18

Q3 K1

R2

R3

R4

R5

R6

R7

R8

R9

U3

U16

U9

R17

R16

C6

J2

R12

R27

U2

U15

CR2

C48

U27

C27

C25

U26

C26 C28

U11

U14

U31

CR11

U12

J11

U13

J3

J7A

C31

J9 J10

ON

OFF

JMP5

CR5 R21

BT1

Figure 1: Model 1092/1093 Main Board ROM Location

4

Arbiter Systems, Inc.

· 1324 Vendels Circle, Suite 121 · Paso Robles, CA 93446 · USA · Tel: +1.805.237.3831

Fax: +1.805.238.5717

· E-mail: [email protected]

· Internet: http://www.arbiter.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement