Arbiter Systems 1092A, 1092B, 1092C, 1093A, 1093B Quick Start Manual
Add to my manuals
4 Pages
Arbiter Systems 1092A
The Arbiter Systems 1092A is a GPS Satellite Controlled Clock that provides accurate timekeeping and synchronization for a wide range of applications. The device features:
- Automatic time synchronization via GPS satellites
- High-precision timekeeping with accuracy up to 100 nanoseconds
- Multiple time reference inputs, including IRIG-B and 1PPS
- Flexible configuration options to meet specific application requirements
- Compact and rugged design for reliable operation in harsh environments
Typical use cases for the Arbiter Systems 1092A include:
- Telecommunications networks
advertisement
Model 1092/1093 Program ROM Update
1 Introduction
This document provides instruction to replace the program ROM (firmware) in the Model 1092A/B/C and Model 1093A/B/C series GPS Satellite Controlled Clocks. Basic understanding of electrical safety and static protection is expected.
2 Required Equipment
1. Torx T-25 or large flat-blade screw driver
2. IC Removal Tool, curved tweezers or small blade screwdriver
3 Saving Original Configuration
Updating the firmware will erase the clock’s configuration. Document the existing settings for reference.
1. 1092B and 1093B/C: press SETUP and sequentially scroll through the various menus.
2. Press ENTER on any menu to sequence through that menu’s settings.
3. 1092A and 1093A: unfortunately, many settings cannot be queried. Use the Operation Manual for a list of serial commands to set local offset, Daylight Saving Time, broadcast modes, IRIG-B time and control functions, etc.
4 Disassembly
1. Disconnect power.
2. Remove from service.
3. Remove the four screws securing the cover with a T-25 driver (or flat-blade screwdriver).
4. Lift off the cover.
5 Installing the Program ROM
1. The program ROM is located at U2 (see Figure 1 on page 4).
2. Remove the old program ROM using the appropriate IC removal tool.
3. Install the new ROM.
Observe the correct IC orientation and make sure the IC pins line up well on both sides of the socket. If necessary, use a pin-bending tool to line up the pins.
4. Option 28: If present, the Power System Time, Frequency, and Phase Monitor may also require an update ROM. Follow the separate instructions for the update steps.
6 Reassembly
1. Replace the cover.
2. Install the four screws securing the cover with a T-25 driver (or flat-blade screwdriver).
3. Place into service.
4. Connect the power.
5. Set to factory defaults.
7 Configuration
7.1
Factory Defaults
7.1.1
Front Panel (B and C Models)
1. Press and release SETUP at startup and during the first two splash screens.
If not displayed then start over.
2. Display will show SET FACTORY DEFAULTS?
3. Press ENTER and follow the on-screen prompts.
Arbiter Systems, Inc.
Fax: +1.805.238.5717
· 1324 Vendels Circle, Suite 121 · Paso Robles, CA 93446 · USA · Tel: +1.805.237.3831
· E-mail: [email protected]
· Internet: http://www.arbiter.com
PD0030600I
1
Model 1092/1093 Program ROM Update
7.1.2
Serial
1. Connect a null-modem cable between a computer and the main serial port on the clock.
2. Open a terminal program (e.g. PuTTY) with port settings of 9600, 8, N, 1.
3. Type into terminal: 1092XX
7.2
Model Select
1. Type in the serial command listed below according to your clock model.
Model Serial Command Model Serial Command
1092A 0,1,1092XZ 1093A 3,1,1093XZ
1092B
1092C
1,1,1092XZ
2,1,1092XZ
1093B
1093C
4,1,1093XZ
5,1,1093XZ
2. Verify model configuration by cycling power and watching LCD display. If Model is incorrect then retype the Model Select command.
7.3
Option Setup
7.3.1
Front Panel
1. Press SETUP to enter the configuration menus.
2. Press UP, DOWN, and ENTER to navigate the menus and configuration selections.
3. Press any top row button to exit the configuration menus.
4.
NOTE: Cycle power to make sure the main processor and the option are communicating.
7.3.2
Serial
Command Description
M,N,K,LXI Where:
M = Option Location (0 = Main Board, 1 = Aux Board)
N = Option Number
Option Code (N = ) 0 1 2
Main Board Option (M = 0) none 19 –
3
–
4
–
5
–
6
–
7
–
8
–
9
–
Aux. Board Option (M = 1) none 03 20A 27 28 29 32 33 34 35
K = security tree (model number, e.g. 1092 or 1093)
L = (use only if N selects Option 28) L = 0 for 60 Hz; L = 1 for 50 Hz
Example: 1,8,1093XI Model 1093A/B/C with Option 34
Example: 1,4,1093,0XI Model 1093A/B/C with Option 28 and 60 Hz reference
NOTE: Cycle power to make sure the main processor and the option are communicating.
2
Arbiter Systems, Inc.
· 1324 Vendels Circle, Suite 121 · Paso Robles, CA 93446 · USA · Tel: +1.805.237.3831
Fax: +1.805.238.5717
· E-mail: [email protected]
· Internet: http://www.arbiter.com
Model 1092/1093 Program ROM Update
7.4
Typical Configuration List
Function
Local Offset
Command Description
±
hh:[mm]L Where: hh = Hour mm = Minute (15 minute increments)
Out-of-Lock Delay
IRIG-B Data - Time Offset
IRIG-B Data - IEEE 1344
Daylight Saving Time Mode
Daylight Saving Time Start
[-]nK
Example: -8L Pacific Time Zone
Where:
- = disabled n = delay in minutes (0 to 99)
Example: -1K Disabled
IL
IU
I0
I1
1,mDT
Example: 10K 10 Minute Delay
Set to local time code reference.
Set to UTC time code reference.
Set IEEE 1344 extension Off.
Set IEEE 1344 extension On.
Set how Daylight Saving Time operates.
Where: m = mode (0 = Off, 1 = On, 2 = Auto)
Example: 1,2DT Automatically adjust for DST per configuration.
2,w,x,y,zDT Set Daylight Saving Time start time.
Daylight Saving Time Stop
Daylight Saving Time Review
Where: w = month (0 = JAN, 11 = DEC) x = week of month (0 = First, 1 = Second,
2 = Third, 3 = Last, 4 = Second from Last,
5 = 3rd from Last) y = day of week (0 = SUN, 6 = SAT) z = minutes after midnight (0 to 1440)
Example: 2,2,1,0,120DT DST begins at 2:00 am on the second Sunday of March.
2,w,x,y,zDT Set Daylight Saving Time stop time.
0DT
Where: w = month (0 = JAN, 11 = DEC) x = week of month (0 = First, 1 = Second,
2 = Third, 3 = Last, 4 = Second from Last,
5 = 3rd from Last) y = day of week (0 = SUN, 6 = SAT) z = minutes after midnight (0 to 1440)
Example: 3,10,0,0,120DT DST ends at 2:00 am on the first Sunday of November.
Return Daylight Saving Time Configuration.
Arbiter Systems, Inc.
Fax: +1.805.238.5717
· 1324 Vendels Circle, Suite 121 · Paso Robles, CA 93446 · USA · Tel: +1.805.237.3831
· E-mail: [email protected]
· Internet: http://www.arbiter.com
3
Model 1092/1093 Program ROM Update
Program ROM
Location
J7B J6 J4 J5 J7
L1
C45
U25 B
A
JMP6
CR4
R20 Q6
JMP2
A
B
CR1 C8
+
R14
JMP1
A
B
CR3
Q5
R19
R*
Q4
DRILL VIA BEFORE
INSTALLING
U28
CR6
C17
C19 C18 C20
U10
U18
C35
+
TP1
+5V
C41
C42
+
+
TP2
GND
C36
C38
C37
+
+
C39
C49
+
+
C34
C33
C43
C40
+
A
B
Y2
C46
C47
CR7
L2
R41
R36
JMP7
U29
C44
+
SERIAL NUMBER
CR8
L3
TP3
+12V
TP4
-12V
1092/1093
PROCESSOR/CONTROLLER
PART NUMBER
LB00189
TAB
REV.
R15
U20
U24 JMP4
U8
VIA
BEFORE
DRILL
INSTALLING
U1
U19
Y1
CR9
R40
CR10
C2
C1 R22
C7
U17
C9
U7 U6
Q2 Q1
VIA
BEFORE
DRILL
INSTALLING
R13
C5
R11
R10
JMP3
R1
U5
C10
U4
R18
Q3 K1
R2
R3
R4
R5
R6
R7
R8
R9
U3
U16
U9
R17
R16
C6
J2
R12
R27
U2
U15
CR2
C48
U27
C27
C25
U26
C26 C28
U11
U14
U31
CR11
U12
J11
U13
J3
J7A
C31
J9 J10
ON
OFF
JMP5
CR5 R21
BT1
Figure 1: Model 1092/1093 Main Board ROM Location
4
Arbiter Systems, Inc.
· 1324 Vendels Circle, Suite 121 · Paso Robles, CA 93446 · USA · Tel: +1.805.237.3831
Fax: +1.805.238.5717
· E-mail: [email protected]
· Internet: http://www.arbiter.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement