Spirax Sarco Thermo-Dynamic Steam Trap TD42 Installation and Maintenance Instructions


Add to my manuals
2 Pages

advertisement

Spirax Sarco Thermo-Dynamic Steam Trap TD42 Installation and Maintenance Instructions | Manualzz

INSTALLATION AND MAINTENANCE INSTRUCTIONS

IM-2-502-US September 2011

Description

The TD42L and TD42H are maintainable thermodynamic steam traps with integral strainer. The TD42L is specifically designed for relatively small condensate loads and therefore is ideal for main drainage applications. For process type loads the TD42H is available.

All traps have external body surfaces with an electroless nickel plate

(ENP) finish which is oxidation resistant.

Operation

The TD42 is a Thermo-Dynamic ® steam trap which uses a disc to control the release of condensate and to trap steam. The trap cycles open and closed to discharge condensate close to steam temperature and closes tight between discharges.

The disc, which is the only moving part, rises and falls in response to dynamic forces produced by the partial re-evaporation (flashing) of hot condensate. Cool condensate, air and other noncondensible gases enter the trap through the central orifice, lift the disc, and are discharged through the three outlet orifices. When the condensate approaches steam temperature, a portion of it flashes as it enters the trap. The flash steam passes at high velocity over the underside of the disc and collects in the control chamber above. The resulting pressure imbalance forces the disc downward onto the seating surfaces, stopping the flow. The trap remains tightly closed until pressure in the chamber is decreased through condensation of the flash steam, allowing inlet pressure to raise the disc and repeat the cycle.

Limiting Operating Conditions

Max. Operating Pressure (PMO)

Min. Operating Pressure

Max. Return Line Pressure

(Backpressure)

Max. Operating Temperature

600 psig (42 barg)

3.5 psig (0.25 barg)

80% of trap inlet pressure

752°F (400°C) at all operating pressures

Installation

Full-flow isolating valves should be installed so as to permit the isolation of the trap from both supply and return line pressure.

The trap will operate in any position, but the preferred installation is in a horizontal pipe.

Maintenance

This product can be maintained without disturbing the piping connections. Complete isolation of the trap from both supply and return line pressure is required before any service can be performed.

If a blowdown valve is installed, it should be opened to release any residual pressure.

Remove the cap. If the disc and body seating faces are only slightly worn they can be refaced by lapping individually on a perfectly flat surface such as a lapping plate.

If the wear is too great to be rectified by simple lapping, the seating faces on the body must be ground flat and then lapped and the disc replaced. The total amount of metal removed in this manner should not exceed 0.010” (.25 mm).

TD42 with blowdown option disc strainer screen

3/8" NPT cap assembly gasket strainer cap

The disc is replaced with the groove side down. A small amount of high-temperature anti-seize compound should be applied to the cap threads on the body, and the cap tightened to the torque listed below.

Operation of Blowdown Valve (if supplied)

Hand protection is recommended before discharging the blowdown valve.

To blowdown the strainer or depressurize the trap apply a 1/2” wrench to the flats on the valve screw. Rotate the valve screw counter clockwise (about two to three complete revolutions) to release the contents of the strainer. Note: when opening blowdown valve screw, make sure that the blowdown valve body does not turn at all. If the blowdown valve turns, it must be held in place with a second wrench.

The valve will discharge from the side of the blowdown valve 90 degrees from the valve screw downward away from the operator. When closing the blowdown valve do not use excessive force to close the valve as it can cause damage to the sealing surfaces. If the valve does not shutoff with minimal force reopen and close the valve again.

To Clean or Replace the Strainer

Complete isolation of the trap from both supply and return line pressure is required before any service can be performed.

Unscrew the strainer cap, withdraw the screen and clean. If the screen shows any signs of damage, replace it immediately.

To re-assemble, place strainer cap gasket over thread and insert the screen in the cap, then screw the cap into place. A fine smear of

Molybdenum Disulphide grease should be applied to the threads.

Recommended Tightening Torques

Cap Assembly 100-110 ft•lb (135-150 Nm) all TD42L

Cap Assembly 134-148 ft•lb (180-200 Nm) all TD42H

Strainer Cap 126-144 ft•lb (170-190 Nm)

Blowdown Valve 50 ft•lb (68 Nm)

}

A

C

B

Steam

TD42

Condensate

Steam trap set

NOTE:

1. Install TD-Trap in horizontal position as close as possible to equipment being drained.

2. Piping to and from the trap should be at least equal to or one size larger than trap connection.

3. Never weld pipe connection to trap. Body material not suitable for welding.

4. Installing cover may rotate and does not affect trap operation.

5. Do not hammer the insulating cover as damage to ceramic and cover may occur.

E

D

Disc (pkt of 3)

Strainer Screen & Gasket

Insulcap Assembly

Gasket (Set of 3)

Blowdown Valve

A

B, D

C

D

E

Available spare parts are shown in heavy line. Parts drawn in broken line are not supplied as spares.

Spirax Sarco Technical Support Department

Toll Free at: 1-800-833-3246

SPIRAX SARCO, INC. • 1150 NORTHPOINT BLVD. • BLYTHEWOOD, SC 29016

PHONE 803-714-2000 • FAX 803-714-2222 www.spiraxsarco.com/us