Hydrants_08.qxd 3/27/08 12:13 PM Page 240
HYDRASAN
®
I Features
The 71000 and 71050 Series (non-freeze) and 71020 and 71070 Series (mild climate) Wall Hydrants supply water for any use in all areas of public and private buildings. These hydrants are designed to be installed in walls of various types of construction. They incorporate features such as integral vacuum breaker-backflow preventer, pressure assisted closure and an automatic pressure relief valve. The 71000 and 71020 Series box type hydrants are for installation where any protrusion may be a hazard, or where aesthetics or potential vandalism dictate secure flush-with-wall concealment of hydrant.
The 71050 and 71070 Series are for installation at the wall surface and are designed so that they will fit into the area occupied by a standard brick.
LATCHING COVER
This discourages vandalism and provides a flush surface in areas where any protrusion from the wall would be considered a hazard.
INSTALLATION
HYDRASAN ® I Hydrant must be installed with head horizontal, outlet to right, (as shown). Complete installation, operation and maintenance instructions accompany each JOSAM HYDRASAN ® Hydrant.
NIKALOY BOX AND SATIN SCORIATED COVER
Satin face, flush-mounted cover.
CONCEALED TYPES
71000 SERIES NON-FREEZE
71020 SERIES MILD CLIMATE
SELF-STORING TOOL
Key-operated, self storing tool assures that, should service ever become necessary, the working parts of the hydrant can be removed, repaired, and reassembled, quickly and easily, from the front, thus returning the hydrant to operation in a short period of time. No special tools are required.
VACUUM BREAKER-BACKFLOW PREVENTER ®
Integral with the hose connection nozzle, responds instantly during normal flow to seal off air ports and permit passage of outflow water. In event of pressure imbalance due to sudden supply pressure drop below outlet or back-pressure, response is immediate to seal against backflow and open air ports to relieve vacuum and backwater to atmosphere. A must for compliance with most plumbing codes for protection of the potable water supply.
EXPOSED TYPES
71050 SERIES NON-FREEZE
71070 SERIES MILD CLIMATE
PRESSURE ASSISTED CLOSURE
Hydrant is closed utilizing the water pressure in the system. The greater the pressure, the more positive the seal. The force of water pressure moves the shuttle into its closed position. This design eliminates the surface to surface grinding created by conventional types of hydrant closures, thus prolonging the life of the working parts. Once sealed, the valve will hold even under upstream pressure drops to zero p.s.i.
PRESSURE RELIEF
Automatic pressure relief valve relieves water pressure in the attached hose and permits air circulation and drainage of hydrant and hose. Drainage will take place providing discharge end of hose is open. This helps prevent bursting of hoses in the event of freezing.
All servicing is accomplished through face of hydrant.
Removal and replacement of seat and shuttle are accomplished by the hydrant’s self-storing tool, which is the actuator rod itself. No special tools are required when hydrant is serviced.
Covered by U.S. and Foreign Patents.
240 WARNING : Cancer and Reproductive Harm - www.p65warnings.ca.gov
Hydrants_08.qxd 3/27/08 12:13 PM Page 241
How To Order Wall Hydrants
Unless optional materials are specified, standard material shown in specification will be provided. Specify wall thickness.
EXAMPLE: Series No. 71000 Type No. 71000-6
71000 -6 -74
Series No.
Wall Thickness in Inches
Option, Union Elbow Assembly
How To Order Yard Hydrants
Unless optional materials are specified, standard material shown in specification will be provided. Specify depth of bury.
EXAMPLE: Series No. 71600 Type No. 71600-91-4
71600 -91 -4 -97
Series No.
-91 1” Hose Pipe Threaded Outlet
Depth Bury in Feet
Option, 1/8” Tapped Drain Hole in Box
WALL HYDRANTS • Non-Freeze
71000 with Vacuum Breaker & Box
71050 with Vacuum Breaker
WALL HYDRANTS • Mild Climate
71020 with Vacuum Breaker & Box
71070 with Vacuum Breaker
Page 245 Page 246
YARD HYDRANTS • Non-Freeze
71400
Standard Duty
71450
Heavy-Duty
Page 245
71600
Heavy-Duty
Page 246
TRI-TEMP
71650
Non-Freeze
Page 247 Page 247 Page 247
WARNING : Cancer and Reproductive Harm - www.p65warnings.ca.gov
Page 248
241
Hydrants_08.qxd 3/27/08 12:13 PM Page 242
Repair Kits
We recommend that a complete HYDRANT REPAIR KIT be installed when it becomes necessary to repair a hydrant.
PART
NO.
71550P02U
#1
ITEM
KIT #2
5/16" Key
QTY.
12
71050P06U
#4
#5/15
KIT #6
Shuttle
Seal/Seat
71050P07U
#1
KIT #7
1/4" Key with Set Screw
Allen Wrench
71050P08U KIT #8
For HYDRASAN® I or II – Non-Freeze
#1
#2
#4
#5
#6
#15
1/4" Key with Set Screw
Actuator
Shuttle
Pressure Assist Rubber Seal
Pressure Relief Valve (O-Ring)
Seat
Allen Wrench
1
1
1
1
1
1
1
12
12
2
2
71070P09U
#4
#5/15
KIT #9
Shuttle
Seal/Seat
71070P10U KIT #10
For HYDRASAN® I or II – Mild Climate
#1
#2
#4
#5
#6
#15
1/4" Key with Set Screw
Actuator
Shuttle
Pressure Assist Rubber Seal
Pressure Relief Valve (O-Ring)
Seat
Allen Wrench
1
1
1
1
1
1
1
2
2
#1
#2
#3
#5
#12
#15
PART
NO.
71950P12U
ITEM
KIT #12
For 1420N - 71950
5/16" Key
Worm Stem
Brass Washer
Packing
Nylon Seat
Plunger
QTY.
#1
#2
#3
#5
#15
71600P14U KIT #14
For 1430N Old Style 3/4" or 1"
1440N or 71700 3/4"
71600 3/4" O.S.
5/16" Key
Worm Stem
Brass Washer
Packing
Plunger
1
1
1
1
1
71600P15U KIT #15
For 71600 3/4" or 1"
New Style
#1
#2
#3
#15
#37
#38
5/16" Key
Worm Stem
Brass Washer
Plunger
Nylon Seal
Worm Stem Seal
1
1
1
1
1
1
1
1
1
1
1
1
#28
#29
#30
#31
º#32
#12
#15
#37
#38
#1
#2
#3
#6
71050P23U
PART
NO.
ITEM
71550P21U KIT #21
For 1400N – 1410N Old Style
71550 – 71650 – Previous Design
QTY.
#5
#12
#15
#1
#2
#3
#4
5/16" Key
Worm Stem
Brass Washer
Packing Nut
Packing
Nylon Seat
Plunger
71550P22U KIT #22
For 71500 – 71550 – 71650
New Style
1
1
1
1
1
1
1
5/16" Key
Worm Stem
Brass Washer
Worm Assy. Nut
Nylon Seat
Plunger
Retainer Seal
Worm Stem Seal
KIT #23
For HYDRASAN® I
Vent Ring
Boot for Vacuum Breaker
Primary Piston
Secondary Piston
Snap Ring
1
1
1
1
1
1
1
1
2
2
2
2
2
242 WARNING : Cancer and Reproductive Harm - www.p65warnings.ca.gov
Hydrants_08.qxd 3/27/08 12:13 PM Page 243
Parts Drawings
Hydrant replacement parts are available in Repair Kits only. See facing page to determine appropriate kit number.
For replacement rod assemblies, contact your local representative.
HYDRASAN ® I 71000 & 71050 Series
HYDRASAN ® I 71020 & 71070 Series
WARNING : Cancer and Reproductive Harm - www.p65warnings.ca.gov
243
Hydrants_08.qxd 3/27/08 12:13 PM Page 244
Typical Installations
71000 Series HYDRASAN ® I installed in an exterior brick wall 71070 Series HYDRASAN ® I installed in an exterior brick wall
Drawing showing how to determine wall thickness Drawing showing how to determine depth of bury
71600 Series Hydrant shown installed in a yard
244
WARNING :
71650 Series TRI-TEMP Hydrant shown installed in a block wall
Cancer and Reproductive Harm - www.p65warnings.ca.gov
Hydrants_08.qxd 3/27/08 12:13 PM Page 245
71000 SERIES HYDRASAN
®
I WITH VACUUM BREAKER • NON-FREEZE
APPLICATION
For use where a potable water supply is required outside a building. The shut off design provides for frost protection and the integral vacuum breaker and backflow preventer protect the potable water supply. The recessed box with hinged latching cover conceals the nozzle and operating mechanism and prevents unauthorized use.
SPECIFICATION
JOSAM 71000 Series cast bronze box type non-freeze wall Hydrant with satin stainless steel hinged latching cover, 3/4" H.P.T. outlet, integral vacuum breaker-backflow preventer, pressure relief valve, bronze casing, bronze operating parts convertible into service tool, 3/4" female and 1" male N.P.T. inlet connection.
Available Options
* -52 Satin Finish Face, Cast Bronze Box
* -54 Satin Finish Face, Cast Nikaloy Box
-72 Wall Clamp
-73 Solder Inlet Adapter
-74 Union Elbow Assembly
-91 1" Hose Pipe Threaded Outlet
-95 Cylinder Vandal-Proof Lock
TYPE NO.
71000-4
71000-6
71000-8
71000-10
71000-12
71000-14
A
4-3/4
6-3/4
8-3/4
10-3/4
12-3/4
14-3/4
71020 SERIES
LBS.
8
9
10
10
10
11
TYPE NO.
71000-16
71000-18
71000-20
71000-22
71000-24
A
16-3/4
18-3/4
20-3/4
22-3/4
24-3/4
LBS.
11
11
12
12
13 r
WHEN UNION ELBOW IS USED, THIS DIM. IS 6-3/8" OVERALL.
* BOX DEPTH IS 1-5/8" ON NIKALOY AND BRONZE BOXES.
HYDRASAN
®
I WITH VACUUM BREAKER • MILD CLIMATE
APPLICATION
For use where a potable water supply is required outside a building. The integral vacuum breaker and backflow preventer protect the potable water supply. The recessed box with hinged latching cover conceals the nozzle and operating mechanism and prevents unauthorized use.
SPECIFICATION
JOSAM 71020 Series cast bronze box type mild-climate wall Hydrant with satin stainless steel hinged latching cover, 3/4" H.P.T. outlet, integral vacuum breaker-backflow preventer, pressure relief valve, bronze operating parts convertible into service tool,
3/4" female and 1" male N.P.T. inlet connection.
Available Options
* -52 Satin Finish Face, Cast Bronze Box
* -54 Satin Finish Face, Cast Nikaloy Box
-72 Wall Clamp
-73 Solder Inlet Adapter
-74 Union Elbow Assembly
-91 1" Hose Pipe Threaded Outlet
-95 Cylinder Vandal-Proof Lock
TYPE NO.
71020
LBS.
8 r
WHEN UNION ELBOW IS USED, THIS DIM. IS 7-5/8" OVERALL.
* BOX DEPTH IS 1-5/8" ON NIKALOY AND BRONZE BOXES.
WARNING : Cancer and Reproductive Harm - www.p65warnings.ca.gov
245
Hydrants_08.qxd 3/27/08 12:13 PM Page 246
71050 SERIES HYDRASAN
®
I WITH VACUUM BREAKER • NON-FREEZE
APPLICATION
For use where a potable water supply is required inside or outside a building. The shut off design provides for frost protection and the integral vacuum breaker and backflow preventer protect the potable water supply. Will fit into the area occupied by a standard brick.
SPECIFICATION
JOSAM 71050 Series cast bronze non-freeze wall Hydrant with satin finish Nikaloy face, 3/4"H.P.T. outlet, integral vacuum breaker-backflow preventer, pressure relief valve, bronze casing, bronze operating parts convertible into service tool, 3/4" female and 1" male N.P.T. inlet connection.
Available Options
-50 Satin Finish Bronze Face
-72 Wall Clamp
-73 Solder Inlet Adapter
-74 Union Elbow Assembly
-91 1" Hose Pipe Threaded Outlet
TYPE NO.
71050-3
71050-4
71050-6
71050-8
71050-10
71050-12
A
2-3/4
4
6
8
10
12
71070 SERIES
LBS.
3
4
4
3
3
4
TYPE NO.
71050-14
71050-16
71050-18
71050-20
71050-22
71050-24
A
14
16
18
20
22
24
LBS.
5
6
6
5
5
6 r WHEN UNION ELBOW IS USED, THIS DIM. IS 6-3/8" OVERALL.
HYDRASAN
®
I WITH VACUUM BREAKER • MILD CLIMATE
APPLICATION
For use where a potable water supply is required inside or outside a building. The integral vacuum breaker and backflow preventer protect the potable water supply.
Will fit into the area occupied by a standard brick.
SPECIFICATION
JOSAM 71070 Series cast bronze mild-climate wall Hydrant with satin finish Nikaloy face, 3/4" H.P.T. outlet, integral vacuum breaker-backflow preventer, pressure relief valve, bronze operating parts convertible into service tool, 3/4" female and 1" male
N.P.T. inlet connection.
Available Options
-50 Satin Finish Bronze Face
-72 Wall Clamp
-73 Solder Inlet Adapter
-74 Union Elbow Assembly
-91 1" Hose Pipe Threaded Outlet
246
TYPE NO.
71070
LBS.
4 r
WHEN UNION ELBOW IS USED, THIS DIM. IS 5-3/4" OVERALL.
WARNING : Cancer and Reproductive Harm - www.p65warnings.ca.gov
Hydrants_08.qxd 5/2/08 2:23 PM Page 247
71400 SERIES
APPLICATION
For use where an outside potable water supply is required. N.P.T. hole drains the body for frost protection.
SPECIFICATION
JOSAM 71400 Series galvanized steel non-freeze ground Hydrant with cast iron head, solid brass 3/4” H.P.T. outlet, cam type operating control lever for full or variable flow, stainless steel operating rod, one-piece plunger and 3/4” F.P.T. inlet.
GROUND HYDRANT • NON-FREEZE
TYPE NO.
71400-1
71400-2
71400-3
71400-4
71400-5
71400-6
SIZE
1’ Bury
2’ Bury
3’ Bury
4’ Bury
5’ Bury
6’ Bury
OVERALL LENGTH
45”
57”
69”
81”
93”
105”
LBS.
11
13
15
17
19
21
71450 SERIES GROUND HYDRANT, HEAVY-DUTY • NON-FREEZE
APPLICATION
For use in industrial environments where an outside potable water supply is required.
N.P.T. hole drains the body for frost protection.
SPECIFICATION
JOSAM 71450 Series galvanized steel non-freeze ground Hydrant with heavy-duty cast iron head, solid brass H.P.T. outlet, cam type operating control lever for full or variable flow, stainless steel operating rod, one-piece plunger and 3/4” F.P.T. inlet.
Available Option
-91 1” Hose Pipe Threaded Inlet and Outlet
TYPE NO.
71450-1
71450-2
71450-3
71450-4
71450-5
71450-6
SIZE
1’ Bury
2’ Bury
3’ Bury
4’ Bury
5’ Bury
6’ Bury
OVERALL LENGTH
46”
58”
70”
82”
94”
106”
LBS.
13
15
17
19
21
23
WARNING : Cancer and Reproductive Harm - www.p65warnings.ca.gov
247
Hydrants_08.qxd 5/2/08 1:22 PM Page 248
71600 SERIES YARD HYDRANT, BOX TYPE • NON-FREEZE
APPLICATION
For use where an outside potable water supply is required. The 1/8" NPT hole drains the body for frost protection and the recessed box with hinged latching cover conceals the nozzle and operating mechanism and prevents unauthorized use.
SPECIFICATION
JOSAM 71600 Series cast bronze non-freeze yard Hydrant with 3/4” H.P.T. outlet, satin finish face Nikaloy box, hinged latching cover, bronze casing, Neoprene plunger, removable bronze operating parts and straight inlet with standard hose connection.
Available Options
-52 Satin Finish Face, Bronze Box
-91 1” Hose Pipe Threaded Outlet
-95 Cylinder Vandal-Proof Lock
-97 1/8" Tapped Drain Hole in Box
TYPE NO.
71600-2
71600-3
71600-4
71600-5
71600-6
SIZE
2’ Bury
3’ Bury
4’ Bury
5’ Bury
6’ Bury
LBS.
6
8
11
13
15
71650 SERIES TRI-TEMP WALL HYDRANT, BOX TYPE • NON-FREEZE
APPLICATION
For use where a potable supply of cold, hot or mixed water is required such as dairies or wash down sites. The shut off design provides for frost protection and the recessed box with hinged latching cover conceals the nozzle and operating mechanism and prevents unauthorized use.
SPECIFICATION
JOSAM 71650 Series TRI-TEMP cast bronze non-freeze wall Hydrant with T-Handle, satin finish face Nikaloy box, hinged latching cover, bronze casings, Neoprene plungers, removable nylon seats, removable bronze operating parts, 3/4" female and 1" male N.P.T. inlet connections for hot and cold water and a mixing chamber with 3/4" H.P.T. outlet.
Available Options
-72 Wall Clamps
-73 Solder Inlet Adapters
-74 Union Elbow Assemblies
-81 Vacuum Breaker
-91 1" Hose Pipe Threaded Outlet
-95 Cylinder Vandal-Proof Lock
TYPE NO.
71650-6
71650-8
71650-10
71650-12
71650-14
248
A
6
8
10
12
14
LBS.
24
25
26
27
28
TYPE NO.
71650-16
71650-18
71650-20
71650-22
71650-24
A
16
18
20
22
24
LBS.
29
30
31
32
33 r
WHEN UNION ELBOW IS USED, THIS DIM. IS 5-3/8" OVERALL.
WARNING : Cancer and Reproductive Harm - www.p65warnings.ca.gov
advertisement