EE: ¡CY DOCK MU
MB455 SPF
(3 device bay with 5 HDD slots)
SATA Backplane Module
User Manual
<1> Package indication
Accessories
mt
Button head #6-32 12 pcs
в)
Product Manual Flat head #6-32 20 pcs
<2>Front panel's light signal instruction
FAN FAIL / OVER HEAT RESET 2.1.The Front panel's HDD signal lights are based on three
| | colors in one.
TAM M 1 Г 2.1.1.When HDD is attached to the tray; LED will show
green light, which means power on.
2.1.2.When HDD is running, LED will show orange light
| | | flashing, which means HDD is operating.
|! ПКМ || 2.1.3.When HDD fails, LED will show red light, which
|| means HDD is faulty. (This signal should be
| Il ОД ||! | provided by the HOST see 2.2)
| Ц LUE 1 (LE | | 2.2.HDD FAIL system
| La 8 8 i lit) | 1 2.2.1.This product can not provide the signal, unless the
Mal № | qu “I № | Ш HOST supports this function.
2.2.2.1f the Host can provide HDD fail signal, connect the
cable to the HOST and to the backplane HDD FAIL
1
(A
CH iy) a Ci IY) (id
Г Nr Г
la
|
Ill
HDD1 Power/ HDD3 Power/ HDD5 Power/
Failure Indicator/ Failure Indicator/ Failure indicator! 1 › 2 > 3 ` 4 ` 5.
ccess Indicator | Access Indicator | Access Indicator . . , ,
HDD2 Power/ ~~ HDD4 Power! 2.2.3.When the HDD is damaged, the light will show in red.
a Indicator Access Indicator 2.3.Cooling Fan damaged and product overheat warning:
Cooling Fan's characteristic: this product is designed to be
replaceable; it does not need to turn off power to replace a
new one or remove it.
[О
7
English
2.3.1.When Cooling fan stops running or fail, the Fan Fail light will show red, the alarm start to buzzer,
therefore push the reset button the buzzer will stop; but the light will keep in red until the Fan is
removed or replaced.
2.3.2.1f Cooling Fan is not installed, the fan failure alarm will not transmit any signal.
Temperature control instructions: this product can be set at 45°C ~ 55°C ~ 65°C.
2.3.3.When the product temperature exceeds the temperature set, the light will appear in red, and the
buzzer will start, and then press RESET to stop the buzzer. OVERHEAT light will keep in red,
until the temperature is below the temperature setting.
<3> Back plane description (labeled on the top side of the product).
S-OUT POWER!
POWER2
POWER3
POWER4
POWERS
ACCESS
ACCESS?
ACCESS3
ACCESS4
ACCESS5
TEMP FAIL
45° FAN FAIL
55: TEMP SET RESET
HDD FAIL IN
HDD1 FAIL IN
— 1003 FALL IN
> HDD1- o HDD4 FAIL IN
HDDS FAIL IN
700
e
“e
HDD5 HDD4 HDD3 HDD2
o
SATA CONNECTOR
fo 000] — POWER PORTS
<4>Instructions
A.Slide the button, handle will semi-reject, then remove the tray.
B.Remove the support rail and secure HDD to the removable tray, and then put it back into the
main case.
C.The Cooling Fan is removable when it is not needed.
After removing Cooling Fan, the FAN FAIL system and alarm will not transmit any signal.
Is Q
№ A Bry 7
AN un Eos
| N Г Е
N SIA L N >
A < Sm
% Power supply: 2 x 4 PIN and 1 x15 PIN.
N
f Note:
1.HDD failure will indicate red only when signals are transmitted by host.
(Please refer to HDD-fail signal)
2.The above testing conditions were obtained the surrounding temp. at 25°C
3.Any unrelated changes in the technical specification are subject to change
without prior notice.
4. We will not be liable responsible for any software, hardware or other data
stored within, or interfacing with our product which resulted to being damaged
dysfunctional. Cremax will only be responsible to repair/ service its own
product.
5.SATA II HDD specification has HDD ACCESS signal, but SATA T HDD does
not have it.
6.SATA II HDD signal function design depends on the brand name / types used.
7.For any further inquiries about product application or more related product
_ information, please linked to www.icydock.com. J