ELAP HLS-M Instruction Manual

Add to My manuals
2 Pages

advertisement

ELAP HLS-M Instruction Manual | Manualzz

INSTRUCTION MANUAL

SPECIFICATIONS

Stroke: 1000 ÷ 12000 mm

Supply voltage 10÷24 Vdc, 5Vdc for line-driver output;

power consumption

≤ 60 mA

Output signals: push-pull, line-driver

Zero reference : 1 pulse each encoder revolution

Max speed: 1 m/sec.

HLS

LINEAR WIRE ENCODER

HLS-M

HLS-S

HLS-L

Spring max torque: HLS-S: 700 g – HLS-M: 600/900 g –

HLS-L 1500/2000 g

SUS304 stailess steel wire covered with nylon

Operating temperature: -10 ÷ 60°C ( HLS-S 0 ÷ 60°C) / Relative moisture 35 ÷ 90%

Connections: cable 1 m lg.( HLS-S 0 .5 m)

Protection degree IP64 ( HLS-S IP50)

Type Stroke

HLS-M 1000 - 2000 3000 – 4000 – 5000 mm

HLS-S 1000 mm

HLS-L

6000 – 7000 – 8000 – 9000 - 10000 - 11000 –

12000 mm

Resolution

1 – 0.5 - 0.2 – 0.1 – 0.05 mm

1 – 0.5 - 0.2 – 0.1 – 0.04 mm

1 – 0.5 mm

Wire Ø

0.7 mm

0.6 mm

1 mm

Max load

23 Kg

16 Kg

60 Kg

INSTALLATION

Make sure that the distance to be run by the wire does not exceed the transducer nominal stroke; stretching the wire over its nominal stroke damages the transducer seriously, and causes the decay of the garantee right.

Use 4 M3 screws with the following specifications to fix the encoder: HLS-M and HLS-S screws M3x6 – HLS-L screws M4x10

The wire must run out of the bushing without angle to obtain the best tolerance in measurements.

It is possible to hook the fixing end of the wire at a steady point and move the transducer body instead of the wire.

If the application is not a linear one, use a pulley with a proper diameter to smooth the rotation and avoid damaging the wire.

If the product works in a severe environment, such as in presence of oil, water, heavy dust, iron chipping or any powder which can damage the wire, apply a protective cover.

CONNECTIONS

Carry out the connections as shown in the diagram hereunder.

The cable shield is not connected inside the transducer.

PUSH-PULL output

Supply voltage 10/24 Vdc

Cable Colours Signals

RED

BLACK

WHITE

GREEN

YELLOW

+ Vdc supply

0 Vdc supply

A

B

Z

LINE DRIVER output

Supply voltage 5 Vdc

Standard cable (black)

HLS-M/HLS-L 1 m

HLS-S 0.5 m

Cable length on request (Grey)

RED

BLACK

BLUE

GREEN

YELLOW

PURPLE

ORANGE

BROWN

SHIELD

RED

BLUE

WHITE

GREEN

GREY

BROWN

YELLOW

PINK

SHIELD

Signals

+ Vdc supply

0 Vdc supply

A

B

Z

A

B

Z

Not connected

DIMENSIONS

Transducer HLS-M Dis.M1295

Transducer HLS-S Dis.M2122

Transducer HLS-L Dis.M2120

Further information at URL: https://www.elap.it/wire-transducers/wire-encoder-hls/