CP-UM-5410EC (Not for use in Japan)

C15M

Single Loop Controller

User's Manual

"Installation"

Thank you for purchasing the C15M.

Before operating this product described in this User's Manual, please take note of the following points regarding safety.

Be sure to keep this manual nearby for handy reference.

Please read the "Terms and Conditions" from the following URL before ordering or use: http://www.azbil.com/products/bi/order.html

NOTICE

Be sure that the user receives this manual before the product is used.

Copying or duplicating this user’s manual in part or in whole is forbidden. The information and specifications in this manual are subject to change without notice.

Considerable effort has been made to ensure that this manual is free from inaccuracies and omissions. If you should find an error or omission, please contact Azbil Corporation.

In no event is Azbil Corporation liable to anyone for any indirect, special or consequential damages as a result of using this product.

 2006-2015 Azbil Corporation All Rights Reserved.

This manual explains handling precautions, mounting, wiring procedures,

PV range types, parameter list and main specifications only.

Unpacking

Check the following items when removing the C15MT from its package:

Name

Mounting Bracket

Gasket

User's Manual

Part No.

81409651-001

81409657-001

CP-UM-5410EC

Q'ty

1

1

1

Remarks

This Manual

SAFETY PRECAUTIONS

WARNING

Warnings are indicated when mishandling this product might result in death or serious injury to the user.

CAUTION

Cautions are indicated when mishandling this product might result in minor injury to the user, or only physical damage to this product.

WARNING

Note that incorrect wiring of the C15M can damage the C15M and lead to other hazards. Check that the C15M has been correctly wired before turning the power ON.

Before wiring, or removing/mounting the C15M, be sure to turn the power OFF. Failure to do so might cause electric shock.

Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.

Do not disassemble the C15M.

Doing so might cause electric shock or faulty operation.

CAUTION

Use the C15M within the operating ranges recommended in the specifications (temperature, humidity, voltage, vibration, shock, mounting direction, atmosphere, etc.).

Failure to do so might cause fire or faulty operation.

Do not block ventilation holes.

Doing so might cause fire or faulty operation.

Wire the C15M properly according to predetermined standards.

Also wire the C15M using specified power leads according to recognized installation methods.

Failure to do so might cause electric shock, fire or faulty operation.

Do not allow lead clippings, chips or water to enter the controller case.

Doing so might cause fire or faulty operation.

Firmly tighten the terminal screws at the torque listed in the specifications. Insufficient tightening of terminal screws might cause electric shock or fire.

Do not use unused terminals on the C15M as relay terminals.

Doing so might cause electric shock, fire or faulty operation.

We recommend attaching the terminal cover (sold separately) after wiring the C15M.

Failure to do so might cause electric shock, fire or faulty operation.

Use the relays within the recommended service life.

Continuous use might cause fire or faulty operation.

If there is a risk of a power surge caused by lightning, use a surge absorber (surge protector) to prevent fire or device failure.

Do not operate the keys with a propelling pencil or sharp-tipped object. Doing so might cause faulty operation.

E1

Mounting

■ Location

Install the controller in the following locations:

· Common mode voltages for I/O excluding the power supply and relay contact output: The voltage to ground is 30Vr.m.s max., 42.4V peak max., and 60Vdc max.

· Not high or low temperature / humidity.

· Free from silicone gas and other corrosive gases such as sulfide gas.

· Less dust or soot.

· Appropriately processed locations to prevent direct sunlight, wind or rain.

· Less mechanical vibration and shock.

· Not close to the high voltage line, welding machine or electrical noise generating source.

· The minimum 15 meters away from the high voltage ignition device for a boiler.

· Less effect by the magnetic.

· No flammable liquid or gas.

· Indoors.

■ Mounting Procedure

· The mounting must be horizontal within 10 degrees tilted in back side lowering or within 10 degrees tilted in back side rising.

· In the case of panel mount type (C15MT), the mounting panel should be used with a thickness of less than 9 mm of firm board.

E1

■ External Dimensions

● C15MT (Panel Mount Type)

2 60

Mounting bracket

(Accessory)

48

SDC15 pv sp mode rdy para man ev1 ev2 ev3 ot1 ot2

(unit: mm)

Terminal screw

M3

Handling Precautions

• To fasten this controller onto the panel, tighten a mounting bracket screws, and turn one more half turn when there is no play between the bracket and panel. Excessively tightening the screws may deform the controller case.

● Panel Cutout Dimensions

Stand-alone mounting Gang-mounting

(unit: mm)

30 min.

45

(48xN -3) +0.5

0

(N: number of mounted units)

Handling Precautions

• When three or more units are gang-mounted horizontally, the maximum allowable ambient temperature is 40°C.

• If dustproof or waterproof protection is required, mount the device using the stand-alone mounting method. If gang-mounted, dustproof and waterproof protection may not be maintained.

• Provide a space of at least 50mm or more above and below the controller.

Wiring

Be sure to provide a switch within operator reach for shutting OFF the main power supply to the controller in the main supply wiring.

Also, in case of AC power supply models, the main supply wiring also requires a time-lagged type (T) fuse (rated current: 0.2A, rated voltage: 250 V).

(IEC127)

The following table shows the meaning of the symbols in the terminal wiring label on the controller side:

Symbols Meaning

AC power supply

Caution, fear of electric shock

Caution

Handling Precautions

• Before wiring the C15M, verify the controller's model No. and terminal Nos. written on the label on the side of the body.

Inspect all wiring once wiring work for the C15M has been completed.

• Provide a distance of at least 50cm between I/O lead wires or communications lead wires and power lead wires of 100V min.

Also, do not pass these lead wires through the same piping or wiring duct.

• Be careful not to allow any crimp terminals lugs to touch adjacent terminals.

• To connect 2 (max.) crimp terminals to the same terminal screw, bend the crimp terminals beforehand.

• Connect wires to terminals 1 - 6 and 13 - 18 from the left

(when viewing the terminal block).

• Use crimp terminals compatible with M3 terminal screws, as shown in the diagram.

B

A: 5.8mm max. B: 5.5 to 7.6mm

• When the power to this controller is turned off, the current input circuit is cut off. If you connect two or more current-input type controllers in series, change the current input to voltage input by connecting a resistor (No. 81401325, sold separately).

• Prepare a heater current conductor to send a heater current through the current transformer.

Do not use a heater current that exceeds the specified permissible current as this may damage the controller.

• The controller requires about 6 seconds to start up once the power is turned ON. The controller can be used once it has started up. However, it is recommended to allow a warm-up time of at least 30 minutes to attain the specified accuracy.

• The current transformer input cannot be used for phase control.

• There is no isolation provided between control output 1 and control output 2. Install an isolator as required.

• Do not connect a terminating resistor to either end of the RS-

485 communications line.

Doing so may interfere with communication.

• Make sure that devices and equipment connected to this device have reinforced insulation suitable for the maximum operating voltage of this device's power supply and input/output ports.

● Connection of C15MT

Current transformer inputs

CT1

CT2

13

14

15

Relay

Voltage pulse

Control outputs

1

2

3

1

2

+

Current

1

2

1

2

3

4

5

6

13

14

15

16

17

18

7

8

9

10

11

12

Event outputs

7

8

9

10

1

2

3

Relay

Power supply

11

12

AC power supply

100 to 240Vac

Thermocouple

RTD

PV inputs

+

4

5

6

C

B

A

4

5

6

DA

DB

SG

DI/COM

2

16

1

17

18

16

17

18

Digital inputs

RS-485

Communication

● I/O isolation

Items surrounded by solid lines are insulated from other signals.

Availability of input or output is based on a model number.

Power supply

PV input

Current Transformer input 1

Current Transformer input 2

Loader communication

Digital input 1

Digital input 2

RS-485 Communication

Control output 1

Control output 2

Internal

Circuit

Event output 1

Event output 2

Event output 3

CP-UM-5410EC (Not for use in Japan)

C15M

Single Loop Controller

User's Manual

"Installation"

Thank you for purchasing the C15M.

Before operating this product described in this User's Manual, please take note of the following points regarding safety.

Be sure to keep this manual nearby for handy reference.

Please read the "Terms and Conditions" from the following URL before ordering or use: http://www.azbil.com/products/bi/order.html

NOTICE

Be sure that the user receives this manual before the product is used.

Copying or duplicating this user’s manual in part or in whole is forbidden. The information and specifications in this manual are subject to change without notice.

Considerable effort has been made to ensure that this manual is free from inaccuracies and omissions. If you should find an error or omission, please contact Azbil Corporation.

In no event is Azbil Corporation liable to anyone for any indirect, special or consequential damages as a result of using this product.

 2006-2015 Azbil Corporation All Rights Reserved.

This manual explains handling precautions, mounting, wiring procedures,

PV range types, parameter list and main specifications only.

Unpacking

Check the following items when removing the C15MT from its package:

Name

Mounting Bracket

Gasket

User's Manual

Part No.

81409651-001

81409657-001

CP-UM-5410EC

Q'ty

1

1

1

Remarks

This Manual

SAFETY PRECAUTIONS

WARNING

Warnings are indicated when mishandling this product might result in death or serious injury to the user.

CAUTION

Cautions are indicated when mishandling this product might result in minor injury to the user, or only physical damage to this product.

WARNING

Note that incorrect wiring of the C15M can damage the C15M and lead to other hazards. Check that the C15M has been correctly wired before turning the power ON.

Before wiring, or removing/mounting the C15M, be sure to turn the power OFF. Failure to do so might cause electric shock.

Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.

Do not disassemble the C15M.

Doing so might cause electric shock or faulty operation.

CAUTION

Use the C15M within the operating ranges recommended in the specifications (temperature, humidity, voltage, vibration, shock, mounting direction, atmosphere, etc.).

Failure to do so might cause fire or faulty operation.

Do not block ventilation holes.

Doing so might cause fire or faulty operation.

Wire the C15M properly according to predetermined standards.

Also wire the C15M using specified power leads according to recognized installation methods.

Failure to do so might cause electric shock, fire or faulty operation.

Do not allow lead clippings, chips or water to enter the controller case.

Doing so might cause fire or faulty operation.

Firmly tighten the terminal screws at the torque listed in the specifications. Insufficient tightening of terminal screws might cause electric shock or fire.

Do not use unused terminals on the C15M as relay terminals.

Doing so might cause electric shock, fire or faulty operation.

We recommend attaching the terminal cover (sold separately) after wiring the C15M.

Failure to do so might cause electric shock, fire or faulty operation.

Use the relays within the recommended service life.

Continuous use might cause fire or faulty operation.

If there is a risk of a power surge caused by lightning, use a surge absorber (surge protector) to prevent fire or device failure.

Do not operate the keys with a propelling pencil or sharp-tipped object. Doing so might cause faulty operation.

Mounting

■ Location

Install the controller in the following locations:

· Common mode voltages for I/O excluding the power supply and relay contact output: The voltage to ground is 30Vr.m.s max., 42.4V peak max., and 60Vdc max.

· Not high or low temperature / humidity.

· Free from silicone gas and other corrosive gases such as sulfide gas.

· Less dust or soot.

· Appropriately processed locations to prevent direct sunlight, wind or rain.

· Less mechanical vibration and shock.

· Not close to the high voltage line, welding machine or electrical noise generating source.

· The minimum 15 meters away from the high voltage ignition device for a boiler.

· Less effect by the magnetic.

· No flammable liquid or gas.

· Indoors.

■ Mounting Procedure

· The mounting must be horizontal within 10 degrees tilted in back side lowering or within 10 degrees tilted in back side rising.

· In the case of panel mount type (C15MT), the mounting panel should be used with a thickness of less than 9 mm of firm board.

E1

■ External Dimensions

● C15MT (Panel Mount Type)

2 60

Mounting bracket

(Accessory)

48

SDC15 pv sp mode rdy para man ev1 ev2 ev3 ot1 ot2

(unit: mm)

Terminal screw

M3

Handling Precautions

• To fasten this controller onto the panel, tighten a mounting bracket screws, and turn one more half turn when there is no play between the bracket and panel. Excessively tightening the screws may deform the controller case.

● Panel Cutout Dimensions

Stand-alone mounting Gang-mounting

(unit: mm)

30 min.

45

(48xN -3) +0.5

0

(N: number of mounted units)

Handling Precautions

• When three or more units are gang-mounted horizontally, the maximum allowable ambient temperature is 40°C.

• If dustproof or waterproof protection is required, mount the device using the stand-alone mounting method. If gang-mounted, dustproof and waterproof protection may not be maintained.

• Provide a space of at least 50mm or more above and below the controller.

Wiring

Be sure to provide a switch within operator reach for shutting OFF the main power supply to the controller in the main supply wiring.

Also, in case of AC power supply models, the main supply wiring also requires a time-lagged type (T) fuse (rated current: 0.2A, rated voltage: 250 V).

(IEC127)

The following table shows the meaning of the symbols in the terminal wiring label on the controller side:

Symbols Meaning

AC power supply

Caution, fear of electric shock

Caution

Handling Precautions

• Before wiring the C15M, verify the controller's model No. and terminal Nos. written on the label on the side of the body.

Inspect all wiring once wiring work for the C15M has been completed.

• Provide a distance of at least 50cm between I/O lead wires or communications lead wires and power lead wires of 100V min.

Also, do not pass these lead wires through the same piping or wiring duct.

• Be careful not to allow any crimp terminals lugs to touch adjacent terminals.

• To connect 2 (max.) crimp terminals to the same terminal screw, bend the crimp terminals beforehand.

• Connect wires to terminals 1 - 6 and 13 - 18 from the left

(when viewing the terminal block).

• Use crimp terminals compatible with M3 terminal screws, as shown in the diagram.

B

A: 5.8mm max. B: 5.5 to 7.6mm

• When the power to this controller is turned off, the current input circuit is cut off. If you connect two or more current-input type controllers in series, change the current input to voltage input by connecting a resistor (No. 81401325, sold separately).

• Prepare a heater current conductor to send a heater current through the current transformer.

Do not use a heater current that exceeds the specified permissible current as this may damage the controller.

E2

• The controller requires about 6 seconds to start up once the power is turned ON. The controller can be used once it has started up. However, it is recommended to allow a warm-up time of at least 30 minutes to attain the specified accuracy.

• The current transformer input cannot be used for phase control.

• There is no isolation provided between control output 1 and control output 2. Install an isolator as required.

• Do not connect a terminating resistor to either end of the RS-

485 communications line.

Doing so may interfere with communication.

• Make sure that devices and equipment connected to this device have reinforced insulation suitable for the maximum operating voltage of this device's power supply and input/output ports.

● Connection of C15MT

Current transformer inputs

CT1

CT2

13

14

15

Relay

Voltage pulse

Control outputs

1

2

3

1

2

+

Current

1

2

1

2

3

4

5

6

13

14

15

16

17

18

7

8

9

10

11

12

Event outputs

7

8

9

10

1

2

3

Relay

Power supply

11

12

AC power supply

100 to 240Vac

Thermocouple

RTD

PV inputs

+

4

5

6

C

B

A

4

5

6

DA

DB

SG

DI/COM

2

16

1

17

18

16

17

18

Digital inputs

RS-485

Communication

● I/O isolation

Items surrounded by solid lines are insulated from other signals.

Availability of input or output is based on a model number.

Power supply

PV input

Current Transformer input 1

Current Transformer input 2

Loader communication

Digital input 1

Digital input 2

RS-485 Communication

Control output 1

Control output 2

Internal

Circuit

Event output 1

Event output 2

Event output 3

E2

Part names and functions

SDC15 pv

(1)

(4) sp mode rdy man ev1 para ev2 ev3 ot1 ot2

(2)

(3)

SDC15

(5) (6)

(7)

(1) Upper display:

(2) Lower display:

(3) Mode indicator rdy: man:

Lights when READY (control stop)

Lights when MANUAL (manual mode) ev1 to ev3: Lights when event relays are ON.

ot1 to ot2: Lights when the control output is ON.

(4) Mode key:

Displays PV values (current temperature, etc.) or setup items.

Displays SP values (set temperature, etc.) and other values of setup items.

(5) Para key:

(6)

<

, , keys:

The operation which was set beforehand can be done by pressing the key for 1s or more.

Factory setting is RUN / READY selection.

Switches the display.

(7) Loader connector:

Used for incrementing numeric values and performing arithmetic shift operations.

Connects to a personal computer with the special cable provided in the smart loader package.

Key Operation and Setting

The following shows the flow of the key operation. Various displays and settings can be called up to the console:

Display when the power is turned ON.

pv sp mode rdy man ev1 ev2 ev3 ot1 para ot2

Off.

Off.

The mode indicator is lit sequentially from the left.

The mode indicators are lit sequentially from the left during a period of 6 sec. after the power has been turned ON while both the upper display and lower display are off.

When all mode indicators have been lit, the display is changed to the operation display.

pv

Operation display

Keep the [para] key pressed for

2 sec. or longer.

No key operation for

3 minutes or more.

Press the [mode] key.

Keep the [para] key pressed for

2 sec. or longer.

Parameter setup display

No key operation for

3 minutes or more.

Press the [mode] key.

Keep the [para] key pressed for 2 sec. or longer.

Setup setting display pv pv sp mode

PV/SP display

Press the [para] key.

sp mode

AUTO/MANUAL selection

Press the [para] key.

sp mode

PV range type setup

Press the [para] key.

pv sp mode

MV display

Press the [para] key.

Other display and setup

(Operate the [para] key repeatedly.)

Press the [para] key.

pv sp mode

RUN/READY selection

Press the [para] key.

Other setup

(Operate the [para] key repeatedly.)

Press the [para] key.

pv sp mode

Temperature unit setup

Press the [para] key.

Other setup

(Operate the [para] key repeatedly.)

Press the [para] key.

The display and setup status shown above are examples for explanation. Therefore, some displays or settings are not shown actually according to the model and/or setup contents.

● PV Input range setup

In the setup setting display mode [C01] , press the [<] • [ ] • [ ] key to set the lower display to select a desired PV range type.

>> When no keys are pressed for 2 sec. or longer, the flashing of the numeric value is stopped to set the currently displayed value.

● SP setup

While the PV/SP is displayed in the operation display mode, press the

[<] • [ ] • [ ] key to change the SP in the lower display.

>> When no keys are pressed for 2 sec. or longer, the flashing of the numeric value is stopped to set the currently displayed value.

SP can be set in the parameter setting display mode.

PV range table

C01 No. Sensor type Range[°C]

1 K

Range[°F]

-200 to +1200 -300 to +2200

2

3

K

K

0 to 1200

0.0 to 800.0

0 to 2200

0 to 1500

6

9

4

5

10

K

K

K

J

J

0.0 to 600.0

0.0 to 400.0

-200.0 to +400.0 -300 to +700

0.0 to 800.0

0.0 to 600.0

0 to 1100

0 to 700

0 to 1500

0 to 1100

C01 No. Sensor type Range[°C]

41 Pt100

Range[°F]

-200 to +500 -300 to +900

42

43

JPt100

Pt100

-200 to +500 -300 to +900

-200 to +200 -300 to +400

44

45

46

51

52

JPt100

Pt100

JPt100

Pt100

-200 to +200 -300 to +400

-100 to +300 -150 to +500

-100 to +300 -150 to +500

-50.0 to +200.0 -50 to +400

JPt100 -50.0 to +200.0 -50 to +400

16

17

18

19

11

13

14

15

J

E

T

R

S

B

N

PL II

-200.0 to +400.0 -300 to +700

0.0 to 600.0

0 to 1100

-200.0 to +400.0 -300 to +700

0 to 1600 0 to 3000

0 to 1600

0 to 1800

0 to 1300

0 to 1300

0 to 3000

0 to 3300

0 to 2300

0 to 2300

20 WRe5-26 0 to 1400

21 WRe5-26 0 to 2300

24

25

DIN U

DIN L

0 to 2400

0 to 4200

-200.0 to +400.0 -300 to +700

-100.0 to +800.0 -150 to +1500

53

54

63

64

67

68

Pt100 -50.0 to +100.0 -50 to +200

JPt100 -50.0 to +100.0 -50 to +200

Pt100 0.0 to 200.0

JPt100 0.0 to 200.0

0 to 400

0 to 400

Pt100

JPt100

0 to 500

0 to 500

0 to 900

0 to 900

C01 No.

Input type

84 0 to 1V

86 1 to 5V

87

88

89

0 to 5V

0 to 10V

0 to 20mA

Range

The scaling and decimal point position can be changed variably in a range of

–1999 to +9999

90 4 to 20mA

Handling Precautions

· The accuracy of the B thermocouple is ±5%FS for a range of

260°C or less, and ±1%FS for 260 to 800°C.

· The accuracy of the PLII thermocouple(CO1 No.19) in the range of 0 to 32˚F does not meet the indication accuracy specified in the Specifications.

· For ranges with a decimal point, tenths are displayed on the line underneath point.

· Make sure to set the correct number in setup display C01, according to the type and range of the sensor used. If the setting is wrong, problems such as large temperature errors in the output may occur.

Alarm code table

Alarm code

AL01

AL02

AL03

AL11

AL70

AL95

AL96

AL97

AL98

AL99

Error

PV input error

(over range)

PV input error

(under range)

CJ failure

Cause

Sensor line break, incorrect wiring, incorrect range code setting

Sensor line break, incorrect wiring, incorrect range code setting

Terminal temperature compensation unit failure

(thermocouple)

PV input error Sensor line break, incorrect wiring (RTD)

CT input failure

(over-range)

A current exceeding the upper limit of the display range was

(CT input 1 or 2,or both) measured. The number of CT turns or the number of CT power wire loops is incorrectly set, or wiring is incorrect.

Countermeasure

Checking wiring or reset range code.

Checking the allowable ambient temperature.

Checking wiring.

• Use a CT with the correct number of turns for the display range.

• Reset the number of

CT turns.

• Reset the number of

CT power wire loops.

• Check the wiring.

Replace unit.

Reset data or replace unit.

A/D conversion error

Parameter error

Defective A/D converter

•Power turned OFF during fixing of data

• Data corrupted due to noise, etc.

Adjustment data error •Power turned OFF during fixing of data

• Data corrupted due to noise, etc.

Parameter error

(RAM area)

Data corrupted due to noise, etc.

Adjustment data error Data corrupted due to noise, etc.

(RAM area)

ROM error Data corrupted due to noise, etc.

Replace unit.

E3 E2

Maintenance

Cleaning: When wiping out the C15M, use the soft and dried cloth.

Parts replacement: Do not replace the parts.

Fuse replacement: When replacing the fuse for the power supply wires, make sure that the replacement fuse complies with all applicable safety standards.

Standard IEC127, Cutoff Speed Delayed operation type (T),

Rated Voltage 250V, Rated Current 0.2A

Basic Mounting Control model No.

output

C15M

T

Model selection table

PV Power Optional Additional input supply functions processing

Specifications

R0

V0

C0

T

R

L

A

01

02

03

00

01

Panel mount type

Control output 1 Control output 2

Relay output (NO) Relay output (NC)

Voltage pulse output None

(for SSR drive)

Current output None

Thermocouple input

(K, J, E, T, R, S, B, N, PL II, WRe5-26,

DINU, DINL)

RTD input (Pt100/JPt 100)

DC voltage /DC current input (0 to 1Vdc,

1 to 5Vdc, 0 to 5Vdc, 0 to 10Vdc, 0 to

20mAdc, 4 to 20mAdc)

AC Model (100 to 240Vac)

Event relay output: 3 points

Event relay output: 3 points

Current transformer input: 2 points

Digital input: 2 points

Event relay output: 3 points

Current transformer input: 2 points

RS-485 communication

Chinese (Simplified)

Chinese (Traditional)

Specifications

● PV input

Thermocouple:

Resistance temperature detector (RTD):

Pt100 (JIS C1604-1997)

DC voltage:

DC current:

Sampling cycle:

Accuracy :

JPt100 (JIS C1604-1989)

0 to 1V, 1 to 5V, 0 to 5V, 0 to 10V

0 to 20mA, 4 to 20mA

500ms

±0.5%FS±1digit,

±1%FS±1digit for a negative area of the thermocouple (at ambient temperature 23±3°C)

Allowable input:

K,J,E,T,R,S,B,N (JIS C1602-1995)

PL II (Engelhard Industries Data (ITS90))

WRe5-26 (ASTM E988-96(Reapproved 2002))

DIN U,DIN L (DIN 43710-1985)

• -0.5 V to +12 V (thermocouple, RTD, DC, voltage)

• 30 mA max or 4 V max (DC current)

More than the allowable input voltage or current may damage this device.

● Digital input

Input type : Dry contact or open collector

Allowable ON contact resistance : Max.250

Allowable OFF contact resistance : Min.100k

Allowable ON voltage :

Terminal current (ON ) :

Minimum hold time :

Max.1.0V

Approx.7.5mA in case of short circuit

Approx.5.0mA in case of contact resistance

250 Ω

1s or more

● Current transformer input

Number of input points:

Input object:

2 points

Current transformer with 100 to 4,000 turns

(availability is by 100-turn units)

Optional unit Model No.: QN206A

(800 turns, hole diameter: 5.8 mm)

Optional unit Model No.: QN212A

(800 turns, hole diameter: 12mm)

Current measurement lower limit:

Display range lower limit:

0.4Aac (800 turns, 1 time)

Formula; Number of turns ÷ (2000 x number of power wire loops)

Current measurement upper limit: 50.0Aac (800 turns, 1 time)

Formula; Number of turns ÷ (16 x number of power wire loops)

Allowable measured current: 70.0Aac (800 turns, 1 time)

Formula; Number of turns ÷ (16 x number of power wire loops) x 1.4

0.0Aac

Display range upper limit:

Display accuracy:

Display resolution:

70.0Aac (800 turns, 1 time)

Formula; Number of turns ÷ (16 x number of power wire loops) x 1.4

±5%FS

0.1Aac

● Control output

• Relay output

Contact rating :

Life :

NO side 250Vac/30Vdc, 3A (resistive load)

NC side 250Vac/30Vdc, 1A (resistive load)

NO side Min. 50,000 operations

NC side Min. 100,000 operations

Min. switching specifications : 5V, 100mA

Min. ON time / OFF time : 250ms

• Voltage pulse output (for SSR drive)

Open circuit voltage :

Internal resistance :

Allowable current :

19Vdc±15%

82 Ω ±0.5%

Max. 24mAdc (a higher current might cause output circuit failure)

Min. OFF time / ON time : 1ms (Time proportional cycle time < 10s)

• Current output

Output type :

250ms (Time proportional cycle time

10s)

0 to 20mAdc or 4 to 20mAdc current output

Allowable load resistance : Max.600

Output accuracy : ±0.5%FS (at ambient temperature 23±3°C)

±1%FS at 0 to 1mA

● Event relay outputs (ev1 to 3)

Contact rating : 250Vac/30Vdc 2A (resistive load)

Life : Min. 100,000 operations

Min. switching specification : 5V, 10mA (Reference value)

● RS-485 communication

Transmission line :

Transmission speed :

Communication protocol :

Terminating resistor :

3-wire system

4800, 9600, 19200, 38400bps

CPL and MODBUS conforming

Do not connect a terminating resistor.

● Environmental condition

• Operating conditions

Ambient temperature :

Ambient humidity :

Power supply voltage :

0 to 50°C (Gang-mounting: 0 to 40°C)

10 to 90%RH (Without condensation)

AC Model

85 to 264Vac, 50/60Hz±2Hz

(Rated power voltage 100 to 240Vac 50/60Hz)

• Transport conditions

Ambient temperature :

Ambient humidity :

–20 to +70°C

10 to 95%RH (Without condensation)

● Other specifications

Degrees of protection :

Power consumption :

Case front side IP66 /NEMA 4 equivalent

(Only for stand-alone mounting on a panel when an attached gasket is used. )

AC Model

Max. 12VA (100Vac:8VA, 264Vac:12VA)

(6VA for 100Vac and 9VA for 264Vac to our company SDC10 equivalent function)

Non-detected power failure time : Max. 20ms (AC model)

Altitude : Max. 2000m

Mass : Approx.150g (with mounting bracket) at panel mount type

Terminal screw tightening torque : 0.4 to 0.6N·m

Applicable standards : EN61010-1,

Over-voltage category :

EN61326-1 (For use in industrial locations)

During EMC testing, the reading or output may fluctuate by ±10 % FS.

Category II (IEC60364-4-443, IEC60664-1)

Allowable pollution degree : Pollution degree 2

Recommended cables: For thermocouples:

Connect thermocouple wires to the terminals directly. When a thermocouple is connected to terminal block, or wiring distance is long, connect the wire via a shielded compensating lead wire.

For input/output other than thermocouples:

Use a JCS 4364 instrument cable or equivalent. If electromagnetic induction noise is comparatively low, a shielded multiconductor microphone cord (MVVS) may be used.

Accessories and optional parts

Name Model No.

Mounting bracket (for C15MT) 81409651-001 (Accessory)

Gasket (for C15MT)

Current transformer

81409657-001 (Accessory)

QN206A (5.8mm hole dia.)

Hard cover

Soft cover

Terminal cover

QN212A (12mm hole dia.)

81446442-001

81446443-001

81446898-001

Part names and functions

SDC15 pv

(1)

(4) sp mode rdy man ev1 para ev2 ev3 ot1 ot2

(2)

(3)

SDC15

(5) (6)

(7)

(1) Upper display:

(2) Lower display:

(3) Mode indicator rdy: man:

Lights when READY (control stop)

Lights when MANUAL (manual mode) ev1 to ev3: Lights when event relays are ON.

ot1 to ot2: Lights when the control output is ON.

(4) Mode key:

Displays PV values (current temperature, etc.) or setup items.

Displays SP values (set temperature, etc.) and other values of setup items.

(5) Para key:

(6)

<

, , keys:

The operation which was set beforehand can be done by pressing the key for 1s or more.

Factory setting is RUN / READY selection.

Switches the display.

(7) Loader connector:

Used for incrementing numeric values and performing arithmetic shift operations.

Connects to a personal computer with the special cable provided in the smart loader package.

Key Operation and Setting

The following shows the flow of the key operation. Various displays and settings can be called up to the console:

Display when the power is turned ON.

pv sp mode rdy man ev1 ev2 ev3 ot1 para ot2

Off.

Off.

The mode indicator is lit sequentially from the left.

The mode indicators are lit sequentially from the left during a period of 6 sec. after the power has been turned ON while both the upper display and lower display are off.

When all mode indicators have been lit, the display is changed to the operation display.

pv

Operation display

Keep the [para] key pressed for

2 sec. or longer.

No key operation for

3 minutes or more.

Press the [mode] key.

Keep the [para] key pressed for

2 sec. or longer.

Parameter setup display

No key operation for

3 minutes or more.

Press the [mode] key.

Keep the [para] key pressed for 2 sec. or longer.

Setup setting display pv pv sp mode

PV/SP display

Press the [para] key.

sp mode

AUTO/MANUAL selection

Press the [para] key.

sp mode

PV range type setup

Press the [para] key.

pv sp mode

MV display

Press the [para] key.

Other display and setup

(Operate the [para] key repeatedly.)

Press the [para] key.

pv sp mode

RUN/READY selection

Press the [para] key.

Other setup

(Operate the [para] key repeatedly.)

Press the [para] key.

pv sp mode

Temperature unit setup

Press the [para] key.

Other setup

(Operate the [para] key repeatedly.)

Press the [para] key.

The display and setup status shown above are examples for explanation. Therefore, some displays or settings are not shown actually according to the model and/or setup contents.

● PV Input range setup

In the setup setting display mode [C01] , press the [<] • [ ] • [ ] key to set the lower display to select a desired PV range type.

>> When no keys are pressed for 2 sec. or longer, the flashing of the numeric value is stopped to set the currently displayed value.

● SP setup

While the PV/SP is displayed in the operation display mode, press the

[<] • [ ] • [ ] key to change the SP in the lower display.

>> When no keys are pressed for 2 sec. or longer, the flashing of the numeric value is stopped to set the currently displayed value.

SP can be set in the parameter setting display mode.

PV range table

C01 No. Sensor type Range[°C]

1 K

Range[°F]

-200 to +1200 -300 to +2200

2

3

K

K

0 to 1200

0.0 to 800v

0 to 2200

0 to 1500

6

9

4

5

10

K

K

K

J

J

0.0 to 600.0

0.0 to 400.0

-200.0 to +400.0 -300 to +700

0.0 to 800.0

0.0 to 600.0

0 to 1100

0 to 700

0 to 1500

0 to 1100

C01 No. Sensor type Range[°C]

41 Pt100

Range[°F]

-200 to +500 -300 to +900

42

43

JPt100

Pt100

-200 to +500 -300 to +900

-200 to +200 -300 to +400

44

45

46

51

52

JPt100

Pt100

JPt100

Pt100

-200 to +200 -300 to +400

-100 to +300 -150 to +500

-100 to +300 -150 to +500

-50.0 to +200.0 -50 to +400

JPt100 -50.0 to +200.0 -50 to +400

16

17

18

19

11

13

14

15

J

E

T

R

S

B

N

PL II

-200.0 to +400.0 -300 to +700

0.0 to 600.0

0 to 1100

-200.0 to +400.0 -300 to +700

0 to 1600 0 to 3000

0 to 1600

0 to 1800

0 to 1300

0 to 1300

0 to 3000

0 to 3300

0 to 2300

0 to 2300

20 WRe5-26 0 to 1400

21 WRe5-26 0 to 2300

24

25

DIN U

DIN L

0 to 2400

0 to 4200

-200.0 to +400.0 -300 to +700

-100.0 to +800.0 -150 to +1500

53

54

63

64

67

68

Pt100 -50.0 to +100.0 -50 to +200

JPt100 -50.0 to +100.0 -50 to +200

Pt100 0.0 to 200.0

JPt100 0.0 to 200.0

0 to 400

0 to 400

Pt100

JPt100

0 to 500

0 to 500

0 to 900

0 to 900

C01 No.

Input type

84 0 to 1V

86 1 to 5V

87

88

89

0 to 5V

0 to 10V

0 to 20mA

Range

The scaling and decimal point position can be changed variably in a range of

–1999 to +9999

90 4 to 20mA

Handling Precautions

· The accuracy of the B thermocouple is ±5%FS for a range of

260°C or less, and ±1%FS for 260 to 800°C.

· The accuracy of the PLII thermocouple(CO1 No.19) in the range of 0 to 32˚F does not meet the indication accuracy specified in the Specifications.

· For ranges with a decimal point, tenths are displayed on the line underneath point.

· Make sure to set the correct number in setup display C01, according to the type and range of the sensor used. If the setting is wrong, problems such as large temperature errors in the output may occur.

Alarm code table

Alarm code

AL01

AL02

AL03

AL11

AL70

AL95

AL96

AL97

AL98

AL99

Error

PV input error

(over range)

PV input error

(under range)

CJ failure

Cause

Sensor line break, incorrect wiring, incorrect range code setting

Sensor line break, incorrect wiring, incorrect range code setting

Terminal temperature compensation unit failure

(thermocouple)

PV input error Sensor line break, incorrect wiring (RTD)

CT input failure

(over-range)

A current exceeding the upper limit of the display range was

(CT input 1 or 2,or both) measured. The number of CT turns or the number of CT power wire loops is incorrectly set, or wiring is incorrect.

Countermeasure

Checking wiring or reset range code.

Checking the allowable ambient temperature.

Checking wiring.

• Use a CT with the correct number of turns for the display range.

• Reset the number of

CT turns.

• Reset the number of

CT power wire loops.

• Check the wiring.

Replace unit.

Reset data or replace unit.

A/D conversion error

Parameter error

Defective A/D converter

•Power turned OFF during fixing of data

•Data corrupted due to noise, etc.

Adjustment data error •Power turned OFF during fixing of data

•Data corrupted due to noise, etc.

Parameter error

(RAM area)

Data corrupted due to noise, etc.

Adjustment data error Data corrupted due to noise, etc.

(RAM area)

ROM error Data corrupted due to noise, etc.

Replace unit.

E2

Maintenance

Cleaning: When wiping out the C15M, use the soft and dried cloth.

Parts replacement: Do not replace the parts.

Fuse replacement: When replacing the fuse for the power supply wires, make sure that the replacement fuse complies with all applicable safety standards.

Standard IEC127, Cutoff Speed Delayed operation type (T),

Rated Voltage 250V, Rated Current 0.2A

Basic Mounting Control model No.

output

C15M

T

Model selection table

PV Power Optional Additional input supply functions processing

Specifications

R0

V0

C0

T

R

L

A

01

02

03

00

01

Panel mount type

Control output 1 Control output 2

Relay output (NO) Relay output (NC)

Voltage pulse output None

(for SSR drive)

Current output None

Thermocouple input

(K, J, E, T, R, S, B, N, PL II, WRe5-26,

DINU, DINL)

RTD input (Pt100/JPt 100)

DC voltage /DC current input (0 to 1Vdc,

1 to 5Vdc, 0 to 5Vdc, 0 to 10Vdc, 0 to

20mAdc, 4 to 20mAdc)

AC Model (100 to 240Vac)

Event relay output: 3 points

Event relay output: 3 points

Current transformer input: 2 points

Digital input: 2 points

Event relay output: 3 points

Current transformer input: 2 points

RS-485 communication

Chinese (Simplified)

Chinese (Traditional)

Specifications

● PV input

Thermocouple:

Resistance temperature detector (RTD):

Pt100 (JIS C1604-1997)

DC voltage:

DC current:

Sampling cycle:

Accuracy :

JPt100 (JIS C1604-1989)

0 to 1V, 1 to 5V, 0 to 5V, 0 to 10V

0 to 20mA, 4 to 20mA

500ms

±0.5%FS±1digit,

±1%FS±1digit for a negative area of the thermocouple (at ambient temperature 23±3°C)

Allowable input:

K,J,E,T,R,S,B,N (JIS C1602-1995)

PL II (Engelhard Industries Data (ITS90))

WRe5-26 (ASTM E988-96(Reapproved 2002))

DIN U,DIN L (DIN 43710-1985)

• -0.5 V to +12 V (thermocouple, RTD, DC, voltage)

• 30 mA max or 4 V max (DC current)

More than the allowable input voltage or current may damage this device.

● Digital input

Input type : Dry contact or open collector

Allowable ON contact resistance : Max.250

Allowable OFF contact resistance : Min.100k

Allowable ON voltage :

Terminal current (ON ) :

Minimum hold time :

Max.1.0V

Approx.7.5mA in case of short circuit

Approx.5.0mA in case of contact resistance

250 Ω

1s or more

● Current transformer input

Number of input points:

Input object:

2 points

Current transformer with 100 to 4,000 turns

(availability is by 100-turn units)

Optional unit Model No.: QN206A

(800 turns, hole diameter: 5.8 mm)

Optional unit Model No.: QN212A

(800 turns, hole diameter: 12mm)

Current measurement lower limit:

Display range lower limit:

0.4Aac (800 turns, 1 time)

Formula; Number of turns ÷ (2000 x number of power wire loops)

Current measurement upper limit: 50.0Aac (800 turns, 1 time)

Formula; Number of turns ÷ (16 x number of power wire loops)

Allowable measured current: 70.0Aac (800 turns, 1 time)

Formula; Number of turns ÷ (16 x number of power wire loops) x 1.4

0.0Aac

Display range upper limit:

Display accuracy:

Display resolution:

70.0Aac (800 turns, 1 time)

Formula; Number of turns ÷ (16 x number of power wire loops) x 1.4

±5%FS

0.1Aac

● Control output

• Relay output

Contact rating :

Life :

NO side 250Vac/30Vdc, 3A (resistive load)

NC side 250Vac/30Vdc, 1A (resistive load)

NO side Min. 50,000 operations

NC side Min. 100,000 operations

Min. switching specifications : 5V, 100mA

Min. ON time / OFF time : 250ms

• Voltage pulse output (for SSR drive)

Open circuit voltage :

Internal resistance :

Allowable current :

19Vdc±15%

82 Ω ±0.5%

Max. 24mAdc (a higher current might cause output circuit failure)

Min. OFF time / ON time : 1ms (Time proportional cycle time < 10s)

• Current output

Output type :

250ms (Time proportional cycle time

10s)

0 to 20mAdc or 4 to 20mAdc current output

Allowable load resistance : Max.600

Output accuracy : ±0.5%FS (at ambient temperature 23±3°C)

±1%FS at 0 to 1mA

● Event relay outputs (ev1 to 3)

Contact rating : 250Vac/30Vdc 2A (resistive load)

Life : Min. 100,000 operations

Min. switching specification : 5V, 10mA (Reference value)

● RS-485 communication

Transmission line :

Transmission speed :

Communication protocol :

Terminating resistor :

3-wire system

4800, 9600, 19200, 38400bps

CPL and MODBUS conforming

Do not connect a terminating resistor.

● Environmental condition

• Operating conditions

Ambient temperature :

Ambient humidity :

Power supply voltage :

0 to 50°C (Gang-mounting: 0 to 40°C)

10 to 90%RH (Without condensation)

AC Model

85 to 264Vac, 50/60Hz±2Hz

(Rated power voltage 100 to 240Vac 50/60Hz)

• Transport conditions

Ambient temperature :

Ambient humidity :

–20 to +70°C

10 to 95%RH (Without condensation)

● Other specifications

Degrees of protection :

Power consumption :

Case front side IP66 /NEMA 4 equivalent

(Only for stand-alone mounting on a panel when an attached gasket is used. )

AC Model

Max. 12VA (100Vac:8VA, 264Vac:12VA)

(6VA for 100Vac and 9VA for 264Vac to our company SDC10 equivalent function)

Non-detected power failure time : Max. 20ms (AC model)

Altitude : Max. 2000m

Mass : Approx.150g (with mounting bracket) at panel mount type

Terminal screw tightening torque : 0.4 to 0.6N·m

Applicable standards : EN61010-1,

Over-voltage category :

EN61326-1 (For use in industrial locations)

During EMC testing, the reading or output may fluctuate by ±10 % FS.

Category II (IEC60364-4-443, IEC60664-1)

Allowable pollution degree : Pollution degree 2

Recommended cables: For thermocouples:

Connect thermocouple wires to the terminals directly. When a thermocouple is connected to terminal block, or wiring distance is long, connect the wire via a shielded compensating lead wire.

For input/output other than thermocouples:

Use a JCS 4364 instrument cable or equivalent. If electromagnetic induction noise is comparatively low, a shielded multiconductor microphone cord (MVVS) may be used.

Accessories and optional parts

E4

Name Model No.

Mounting bracket (for C15MT) 81409651-001 (Accessory)

Gasket (for C15MT)

Current transformer

81409657-001 (Accessory)

QN206A (5.8mm hole dia.)

Hard cover

Soft cover

Terminal cover

QN212A (12mm hole dia.)

81446442-001

81446443-001

81446898-001

E4 r--r

At

Display

A--M do Lt

C. dI 1

■ SP bank

Bank selection: SP

Display

SP- 1 to

SP-4

C15M List of Parameters

[List of Operation Displays]

■ Operation Displays

Display Item Contents

Upper display: PV SP (Target value) SP low limit (C07) to SP high limit (C08)

Lower display: SP

LSP 1

Lower display:

LSP

LSP No. (1st digit: 1 to LSP system group (C30 Max. 4)

Value at the

Out right end digit)

MV (Manipulated –10.0 to +110.0%

Variable) Setting is disabled in AUTO mode.

(Numeric value does not flash.)

Setting is enabled in MANUAL mode.

(Numeric value flashes.)

Setting is disabled

–10.0 to +110.0%

HEAt

COOL

Upper display: PV AT progress

At 1 (display example)

Ct 1

Ct2

E 1

E 1. Sb t 1. --

E2

E2. Sb

Heat MV

(Manipulated

Variable)

Cool MV

(Manipulated

Variable)

Setting is disabled.

display (1st digit Except for 0: During execution of AT

= Numeric value (Value is decreased.) at right end digit) 0: Completion of AT

Setting is disabled.

CT (Current transformer) current value 1

CT (Current Setting is disabled.

transformer) current value 2

Internal event 1 main setting

Internal event 1 sub-setting

Setting range is different depending on the internal event operation type.

–1999 to +9999U: Except below.

0 to 9999U: When the setting value is an absolute value.

–199.9 to +999.9%: For MV.

Timer remaining Setting is disabled.

time 1 Upper display: The distinction by ON delay or OFF delay is displayed at the side location of [t1.].

Lower display: Displayed by the unit (either one of

0.1s, s, or min) based on the internal event 1 delay time unit (E1. the 3rd digit of C3).

Setting range is different depending on the internal event operation type.

–1999 to +9999U: Except below.

t2. --

E3

E3. Sb t3. --

Internal event 2 main setting

Internal event 2 sub-setting

–199.9 to +999.9%: For MV.

Timer remaining Setting is disabled.

time 2

0 to 9999U: When the setting value is an absolute value.

Upper display: The distinction by ON delay or OFF delay is displayed at the side location of [t2.].

Lower display: Displayed by the unit (either one of

0.1s, s, or min) based on the internal event 2 delay time unit (E2. the 3rd digit of C3).

Setting range is different depending on the internal event operation type.

–1999 to +9999U: Except below.

Internal event 3 main setting

Internal event 3 sub-setting 0 to 9999U: When the setting value is an absolute value.

–199.9 to +999.9%: For MV.

Timer remaining Setting is disabled.

time 3 Upper display: The distinction by ON delay or OFF delay is displayed at the side location of [t3.].

Lower display: Displayed by the unit (either one of

0.1s, s, or min) based on the internal event 3 delay time unit(E3. the 3rd digit of C3).

Initial User value level

0 0

-

-

-

-

-

-

-

-

-

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

[List of Parameter Setting Displays]

■ Mode bank

Bank selection: MOdE

Item

AUTO/MANUAL AUTO : AUTO mode mode selection

RUN/READY mode selection

AT Stop/Start selection

Release all DO latches

Communication

DI 1

MAN : MANUAL mode

RUN : RUN mode

RDY : READY mode

At. OF

At. ON

Lt. ON

Lt. OF dI. OF dI. On

: AT Stop

: AT Start

: Latch continue

: Latch release

: OFF

: ON

Contents

Item Contents

SP of LSP1 group to SP low limit (C07) to SP high limit (C08)

LSP4 group

Initial User value level

AUTO 0

RUN

AT Stop

Latch continue

OFF

0

0

0

0

Initial User value level

0 0

■ Event bank

Bank selection: Ev

Display Item

E 1 to E5

E 1. Sb to

E5. Sb

E 1. Hy to

E5. Hy

E 1. On to

E5. On

E 1. OF to

E5. OF

Contents

Internal event 1 to –1999 to +9999

5, main setting The decimal point position varies by meeting the

Internal event 1 to internal event operation type.

5, sub-setting 0 to 9999 for some operation type.

Internal event 1 to 0 to 9999

5, hysteresis

5, ON delay

The decimal point position varies by meeting the internal event operation type.

Internal event 1 to 0.0 to 999.9

(For the delay time unit 0.1s)

Internal event 1 to 0 to 9999

5, OFF delay (Except for the delay time unit 0.1s)

Initial User value level

0 0

0

5

0

0

0

0

2

2

E5

User level details 0: Display in basic / standard / high function,

1: Display in standard / high function,

2: Display in high function.

Initial value may vary depending on model No.

■ PID bank

Bank selection: PId

Display Item

P- 1

I- 1 d- 1 rE- 1

OL- 1

OH- 1

P- 1 C

I- 1 C d- 1 C

OL. 1 C

OH. 1 C

Contents

Proportional band 0.1 to 999.9%

Integration time

Derivative time

Manual reset

0 to 9999s

(0: No integral control action)

0 to 9999s

(0: No derivative control action)

–10.0 to +110.0%

MV low limit

MV high limit

–10.0 to +110.0%

–10.0 to +110.0%

Cool-side proportional band

0.1 to 999.9%

Cool-side integration time

0 to 9999s

(0: No integral control action)

Cool-side derivative time

0 to 9999s

(0: No derivative control action)

Cool-side MV low –10.0 to +110.0% limit

Cool-side MV high –10.0 to +110.0% limit

■ Parameter bank

Bank selection: PArA

Display Item

CtrL

At. OL

At. OH dIFF

OFFS

FL rA bI

CyU

Cy

CyU2

Cy2 tP. ty

SPU

SPd

Contents

Control method

MV low limit at AT

MV high limit at AT

ON/OFF control differential

ON/OFF control operating point differential

PV filter

PV ratio

PV bias

0: ON/OFF control

1: PID fixed

2: ST (Self turning)

–10.0 to +110.0%

–10.0 to +110.0%

0 to 9999U

–1999 to 9999U

0.0 to 120.0s

0.001 to 9.999

–1999 to +9999U

Time proportional cycle unit 1 0: 1s unit

1: 0.5s fixed (Cycle time is disabled.)

2: 0.2s fixed (Cycle time is disabled.)

3: 0.1s fixed (Cycle time is disabled.)

5 to 120s (The output includes the relay Time proportional cycle1 output.)

1 to 120s (The output does not include the relay output.)

Time proportional cycle unit 2 0: 1s unit

Time proportional cycle 2

Time proportional operation type

SP ramp-up

SP ramp-down

1: 0.5s fixed (Cycle time is disabled.)

2: 0.2s fixed (Cycle time is disabled.)

3: 0.1s fixed (Cycle time is disabled.)

5 to 120s (The output includes the relay output.)

1 to 120s (The output does not include the relay output.)

0: Controllability aiming type

1: Actuator life aiming type

(Only one ON/OFF operation within time proportional cycle time)

0.0 to 999.9U (0.0: No ramp)

Initial User value level

0 or 1

0.0

100.0

5

0

0.0

1.000

0

0

10 or 2

0

10 or 2

0 or 1

0.0

0.0

0

0

0

0

2

0

1

0

2

0

2

0

2

2

2

■ Extension tuning bank

Bank selection: Et

Display Item

At. ty

JF. bd

SP. LG

At-P

At-I

At-d

Ctr. A

JF. Ov

St.SA

St.Sb

St.Hb

St.ud

Contents

AT type

Just-FiTTER setting band

SP lag constant

Proportional band tuning factor at AT

0: Normal (Standard control characteristics)

1: Immediate response (Control characteristics immediately responding to the external disturbance.)

2: Stable (Control characteristics with less up/down function of PV)

0.00 to 10.00

0.0 to 999.9

0.00 to 99.99

Integration time tuning factor 0.00 to 99.99

at AT

Derivative time tuning factor 0.00 to 99.99

at AT

Control algorithm

Just-FiTTER overshoot suppression factor

0: PID (conventional PID)

1: Ra-PID (high performance type)

0 to 100

ST step execution resolution 0.00 to 99.99 % width

ST step settling bound 0.00 to 10.00 %

ST hunting settling bound 0.00 to 10.00 %

ST step ramp change 0: ST is executed when the PV ramp up or down.

1: ST is executed only when the PV ramp up.

Initial User value level

1 0

0.30

0.0

1.00

1.00

1.00

0

0

10.00

0.50

1.00

0

1

2

2

2

1

2

1

2

2

2

2

50.0

0.0

100.0

5.0

Initial User value level

5.0

0

120

30

0

0

0

1

1

0

120 0

30

0.0

100.0

0

1

1

E3

[List of Setup Setting Displays]

■ Setup bank

Bank selection: StUP

C 0 1

C 02

C 03

C 04

C 05

C 06

C 07

C 08

C 09

C 14

C 15

C 16

C 17

C 18

C 19

C 20

C 2 1

C 22

C 26

C 27

C 28

C 29

C 30

C 32

C 36

C 37

C 38

C 39

C 40

C 4 1

C 42

C 43

C 44

C 45

C 46

C 47

C 48

C 49

C 50

C 5 1

Display Item

PV range high

Contents

PV input range type

Thermocouple (T): 1 to 6, 9 to 11, 13 to 21, 24, 25

RTD (R): 41 to 46, 51 to 54, 63, 64, 67, 68

DC current/voltage (L): 84, 86 to 90

Temperature unit 0: Centigrade (°C)

Cold junction compensation

(T/C)

Decimal point position

1: Fahrenheit (°F)

0: Cold junction compensation is performed. (Internal)

1: Cold junction compensation is not performed.

(External)

0: No decimal point

1: One digit below decimal point

2: Two digits below decimal point

3: Three digits below decimal point

(Select ‘0’ or ‘1’ for the RTD range with decimal point)

PV range low limit When the PV input range type is thermocouple (T) or

RTD (R), the setting is disabled although range low

SP low limit

SP high limit

Squarer root 0.0 to 100.0% extraction dropout (0.0: No square root extraction)

Control action

(direct/reverse)

Selection of MV at PV alarm

0: Heat control (reverse action))

1: Cool control (direct action)

0: Control operation is continued.

1: MV at PV alarm occurrence is outputted.

occurrence

MV at PV alarm –10.0 to +110.0% occurrence

MV at READY (at –10.0 to +110.0% heat-side for heat/cool control)

MV at READY (at –10.0 to +110.0% cool-side)

Operation at 0: Bump-less

MANUAL change 1: Preset

Preset MANUAL –10.0 to +110.0% value

PID operation initialization

(Used even at MANUAL mode when power is ON.)

0: Automatic

1: Not initialized function selection 2: Initialized (when SP value different from current value is inputted.)

–10.0 to +110.0% PID operation initial MV

Heat/cool control 0: Disabled.

1: Enabled.

Heal/cool selection 0: Normal

1: Energy saving

Dead zone –100.0 to +100.0%

Heal/cool control –10.0 to +110.0% selection point

LSP setting system

SP ramp unit

1 to 4

CT1 operation type

CT1 output

3: Event output 2

4: Event output 3

CT1 measurement 30 to 300ms wait time

CT2 operation type Same as CT1.

CT2 output

CT2 measurement wait time

Control output 1 range

Control output 1 type

0: 0.1U/s

1: 0.1U/min

2: 0.1U/h

0: Heater burnout detection

1: Current value measurement

0: Control output 1

1: Control output 2

2: Event output 1

1: 4 to 2mA

2: 0 to 20mA

0: MV

1: Heat MV

2: Cool MV

3: PV

4: PV before ratio bias filter

5: SP

6: Deviation (PV-SP)

7: CT1 current value

8: CT2 current value

9: Invalid

10: SP+MV

11: PV+MV

–1999 to +9999

(The decimal point position and unit may vary depending on the control output 1 type.)

Control output 1 scaling low limit

Control output 1 scaling high limit

Control output 1 0 to 9999

MV scaling The decimal point position and unit are same as for PV.

Same as control output 1.

Control output 2 range

Control output 2 type

Control output 2 scaling low limit

–1999 to +9999

(The decimal point position and unit may vary

Control output 2 depending on the control output 2 type.) scaling high limit

Control output 2 0 to 9999

MV scaling The decimal point position and unit are same as for PV.

Initial User value level

1

41

88

0

0

0

limit is displayed.

–1999 to +9999U when the PV input range type is DC voltage/current (L).

When the PV input range type is thermocouple (T) or

RTD(R), the setting is disabled although range high limit is displayed.

PV input range low limit to PV input range high limit

0

–1999 to +9999U when the PV input range type is DC 1000 voltage/current (L).

0

-

1000

0.0

0

0

0.0

0.0

0.0

0

0.0 or

50.0

0

0.0 or

50.0

0

0

0.0

50.0

1

1

0

0

30

0

0

30

1

0

0.0

100.0

200

1

3

0

1000

200

0

0

2

0

0

0

1

1

2

0

2

2

1

1

1

1

2

2

0

1

0

2

0

2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

CP-UM-5410EC

C 67

C 68

C 69

C 70

C 7 1

C 72

C 79

C 80

C 90

C 9 1

C 92

C 93

C 64

Display

C 65

C 66

C 73

C 74

C 75

C 76

C 77

C 78

Item Contents

CPL/MODBUS

Station address

Transmission speed

0: CPL

1: MODBUS ASCII format

2: MODBUS RTU format

0 to 127

Communication is disabled when "0" is set.

0: 4800bps

1: 9600bps

2: 19200bps

3: 38400bps

Data format (data 0: 7bits length)

Data format

(parity)

1: 8bits

0: Even parity

1: Odd parity

2: No parity

Data format (stop 0: 1bit bits)

Communication minimum response time

Key operation

1: 2bits

1 to 250ms mode/type

MODE key function

MODE display setup

0: Standard type

1: Special type

0: Invalid

1: AUTO/MANUAL selection

2: RUN/READY selection

3: AT Stop/Start

4: LSP group selection

5: Release of all DO latches

6: Invalid

7: Communication DI1 selection

8: Invalid

Whether the mode bank setup display is enabled or disabled is determined by the sum of the following weighting:

Bit 0: AUTO/MANUAL display

0: Disabled, +1: Enabled

PV/SP value display setup

Bit 1: RUN/READY display

0: Disabled, +2: Enabled

Bit 3: AT stop/start display

0: Disabled, +8: Enabled

Bit 4: DO latch release

0: Disabled, +16: Enabled

Bit 5: Communication DI1 ON/OFF display

0: Disabled, +32: Enabled

Other invalid setup: 0, +4, +64, +128

Whether the basic display is enabled or disabled is determined by the sum of the following weighting:

Bit 0: PV display

0: Disabled, +1: Enabled

Bit 1: SP display

0: Disabled, +2: Enabled

Bit 2: LSP group No. display

0: Disabled, +4: Enabled

Other invalid setup: 0, +8

MV display setup Whether the basic display is enabled or disabled is determined by the sum of the following weighting:

Bit 0: MV display

0: Disabled, +1: Enabled

Bit 1: Heat MV/cool MV display

0: Disabled, +2: Enabled

Other invalid setup: 0, +4

Event setting value 0: In the operation display mode, the internal event display setup

Bit 3: AT progress display

0: Disabled, +8: Enabled setting value is not displayed.

1: In the operation display mode, the internal event 1 setting value is displayed.

2: In the operation display mode, the internal event 1 to 3 setting value is displayed.

Event remaining 0: In the operation display mode, the ON/OFF delay time display setup to 2 setting value is displayed.

3: In the operation display mode, the internal event 1 remaining time of the internal event is not displayed.

1: In the operation display mode, the ON/OFF delay remaining time of the internal event 1 is displayed.

2: In the operation display mode, the ON/OFF delay remaining time of the internal event 1 to 2 is displayed.

3: In the operation display mode, the ON/OFF delay

CT input current 0: In the operation display mode, the CT current value display setup remaining time of the internal event 1 to 3 is displayed.

User level value is not displayed.

1: In the operation display mode, the CT1 current value is displayed.

2: In the operation display mode, the CT1 to 2 current value is displayed.

0: Basic configuration

1: Standard configuration

2: High function configuration

LED monitor 0: Disabled

1: Flashing at RS-485 communication signal transmission

2: Flashing at RS-485 communication signal receiving

3: OR (logical sum) of all DI status

4: Flashing at READY

Number of CT1 0: 800 turns turns 1 to 40: CT turns divided by 100.

Number of CT1 0: 1 time power wire loops 1 to 6: Number of times

Number of CT2 0: 800 turns turns 1 to 40: CT turns divided by 100.

Number of CT2 0: 1 time power wire loops 1 to 6: Number of times

Initial User value level

0 0

0

2

1

0

0

3

0

1

255

15

15

0

0

0

0

0

8

1

8

1

0

0

0

0

0

2

2

0

1

1

1

1

1

1

0

2

2

2

2

2

(continued on back page)

C15M List of Parameters

[List of Operation Displays]

■ Operation Displays

Display Item Contents

Upper display: PV SP (Target value) SP low limit (C07) to SP high limit (C08)

Lower display: SP

LSP 1

Lower display:

LSP

LSP No. (1st digit: 1 to LSP system group (C30 Max. 4)

Value at the

Out right end digit)

MV (Manipulated –10.0 to +110.0%

Variable) Setting is disabled in AUTO mode.

(Numeric value does not flash.)

Setting is enabled in MANUAL mode.

(Numeric value flashes.)

Setting is disabled

–10.0 to +110.0%

HEAt

COOL

Upper display: PV AT progress

At 1 (display example)

Ct 1

Ct2

E 1

E 1. Sb t 1. --

E2

E2. Sb

Heat MV

(Manipulated

Variable)

Cool MV

(Manipulated

Variable)

Setting is disabled.

display (1st digit Except for 0: During execution of AT

= Numeric value (Value is decreased.) at right end digit) 0: Completion of AT

Setting is disabled.

CT (Current transformer) current value 1

CT (Current Setting is disabled.

transformer) current value 2

Internal event 1 main setting

Internal event 1 sub-setting

Setting range is different depending on the internal event operation type.

–1999 to +9999U: Except below.

0 to 9999U: When the setting value is an absolute value.

–199.9 to +999.9%: For MV.

Timer remaining Setting is disabled.

time 1 Upper display: The distinction by ON delay or OFF delay is displayed at the side location of [t1.].

Lower display: Displayed by the unit (either one of

0.1s, s, or min) based on the internal event 1 delay time unit (E1. the 3rd digit of C3).

Setting range is different depending on the internal event operation type.

–1999 to +9999U: Except below.

t2. --

E3

E3. Sb t3. --

Internal event 2 main setting

Internal event 2 sub-setting

–199.9 to +999.9%: For MV.

Timer remaining Setting is disabled.

time 2

0 to 9999U: When the setting value is an absolute value.

Upper display: The distinction by ON delay or OFF delay is displayed at the side location of [t2.].

Lower display: Displayed by the unit (either one of

0.1s, s, or min) based on the internal event 2 delay time unit (E2. the 3rd digit of C3).

Setting range is different depending on the internal event operation type.

–1999 to +9999U: Except below.

Internal event 3 main setting

Internal event 3 sub-setting 0 to 9999U: When the setting value is an absolute value.

–199.9 to +999.9%: For MV.

Timer remaining Setting is disabled.

time 3 Upper display: The distinction by ON delay or OFF delay is displayed at the side location of [t3.].

Lower display: Displayed by the unit (either one of

0.1s, s, or min) based on the internal event 3 delay time unit(E3. the 3rd digit of C3).

Initial User value level

0 0

-

1

0

0

0

0

0

0

-

-

-

-

-

-

-

-

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

[List of Parameter Setting Displays]

■ Mode bank

Bank selection: MOdE

Display

A--M r--r

At do Lt

C. dI 1

Item

AUTO/MANUAL AUTO : AUTO mode mode selection

RUN/READY mode selection

AT Stop/Start selection

Release all DO latches

Communication

DI 1

MAN : MANUAL mode

RUN : RUN mode

RDY : READY mode

At. OF

At. ON

Lt. ON

Lt. OF dI. OF dI. On

: AT Stop

: AT Start

: Latch continue

: Latch release

: OFF

: ON

Contents Initial User value level

AUTO 0

RUN

AT Stop

Latch continue

OFF

0

0

0

0

■ SP bank

Bank selection: SP

Display Item

SP- 1 to

SP-4

Contents

SP of LSP1 group to SP low limit (C07) to SP high limit (C08)

LSP4 group

Initial User value level

0 0

■ Event bank

Bank selection: Ev

Display Item

E 1 to E5

E 1. Sb to

E5. Sb

E 1. Hy to

E5. Hy

E 1. On to

E5. On

E 1. OF to

E5. OF

Contents

Internal event 1 to –1999 to +9999

5, main setting The decimal point position varies by meeting the

Internal event 1 to internal event operation type.

5, sub-setting 0 to 9999 for some operation type.

Internal event 1 to 0 to 9999

5, hysteresis

5, ON delay

The decimal point position varies by meeting the internal event operation type.

Internal event 1 to 0.0 to 999.9

(For the delay time unit 0.1s)

Internal event 1 to 0 to 9999

5, OFF delay (Except for the delay time unit 0.1s)

Initial User value level

0 0

0

5

0

0

0

0

2

2

User level details 0: Display in basic / standard / high function,

1: Display in standard / high function,

2: Display in high function.

Initial value may vary depending on model No.

■ PID bank

Bank selection: PId

Display Item

P- 1

I- 1 d- 1 rE- 1

OL- 1

OH- 1

P- 1 C

I- 1 C d- 1 C

OL. 1 C

OH. 1 C

Contents

Proportional band 0.1 to 999.9%

Integration time

Derivative time

Manual reset

0 to 9999s

(0: No integral control action)

0 to 9999s

(0: No derivative control action)

–10.0 to +110.0%

MV low limit

MV high limit

–10.0 to +110.0%

–10.0 to +110.0%

Cool-side proportional band

0.1 to 999.9%

Cool-side integration time

0 to 9999s

(0: No integral control action)

Cool-side derivative time

0 to 9999s

(0: No derivative control action)

Cool-side MV low –10.0 to +110.0% limit

Cool-side MV high –10.0 to +110.0% limit

■ Parameter bank

Bank selection: PArA

Display Item

CtrL

At. OL

At. OH dIFF

OFFS

FL rA bI

CyU

Cy

CyU2

Cy2 tP. ty

SPU

SPd

Contents

Control method

MV low limit at AT

MV high limit at AT

ON/OFF control differential

ON/OFF control operating point differential

PV filter

PV ratio

PV bias

0: ON/OFF control

1: PID fixed

2: ST (Self turning)

–10.0 to +110.0%

–10.0 to +110.0%

0 to 9999U

–1999 to 9999U

0.0 to 120.0s

0.001 to 9.999

–1999 to +9999U

Time proportional cycle unit 1 0: 1s unit

1: 0.5s fixed (Cycle time is disabled.)

2: 0.2s fixed (Cycle time is disabled.)

3: 0.1s fixed (Cycle time is disabled.)

5 to 120s (The output includes the relay Time proportional cycle1 output.)

1 to 120s (The output does not include the relay output.)

Time proportional cycle unit 2 0: 1s unit

Time proportional cycle 2

Time proportional operation type

SP ramp-up

SP ramp-down

1: 0.5s fixed (Cycle time is disabled.)

2: 0.2s fixed (Cycle time is disabled.)

3: 0.1s fixed (Cycle time is disabled.)

5 to 120s (The output includes the relay output.)

1 to 120s (The output does not include the relay output.)

0: Controllability aiming type

1: Actuator life aiming type

(Only one ON/OFF operation within time proportional cycle time)

0.0 to 999.9U (0.0: No ramp)

Initial User value level

0 or 1

0.0

100.0

5

0

0.0

1.000

0

0

10 or 2

0

10 or 2

0 or 1

0.0

0.0

0

0

2

0

2

2

2

0

2

0

1

0

2

0

0

■ Extension tuning bank

Bank selection: Et

Display Item

At. ty

JF. bd

SP. LG

At-P

At-I

At-d

Ctr. A

JF. Ov

St.SA

St.Sb

St.Hb

St.ud

Contents

AT type

Just-FiTTER setting band

SP lag constant

Proportional band tuning factor at AT

0: Normal (Standard control characteristics)

1: Immediate response (Control characteristics immediately responding to the external disturbance.)

2: Stable (Control characteristics with less up/down function of PV)

0.00 to 10.00

0.0 to 999.9

0.00 to 99.99

Integration time tuning factor 0.00 to 99.99

at AT

Derivative time tuning factor 0.00 to 99.99

at AT

Control algorithm

Just-FiTTER overshoot suppression factor

0: PID (conventional PID)

1: Ra-PID (high performance type)

0 to 100

ST step execution resolution 0.00 to 99.99 % width

ST step settling bound 0.00 to 10.00 %

ST hunting settling bound 0.00 to 10.00 %

ST step ramp change 0: ST is executed when the PV ramp up or down.

1: ST is executed only when the PV ramp up.

Initial User value level

1 0

0.30

0.0

1.00

1.00

1.00

0

0

10.00

0.50

1.00

0

1

2

2

2

1

2

1

2

2

2

2

50.0

0.0

100.0

5.0

Initial User value level

5.0

0

120

30

0

0

0

1

1

0

120 0

30

0.0

100.0

0

1

1

[List of Setup Setting Displays]

■ Setup bank

Bank selection: StUP

C 0 1

C 02

C 03

C 04

C 05

C 06

C 07

C 08

C 09

C 14

C 15

C 16

C 17

C 18

C 19

C 20

C 2 1

C 22

C 26

C 27

C 28

C 29

C 30

C 32

C 36

C 37

C 38

C 39

C 40

C 4 1

C 42

C 43

C 44

C 45

C 46

C 47

C 48

C 49

C 50

C 5 1

Display Item

PV range high

Contents

PV input range type

Thermocouple (T): 1 to 6, 9 to 11, 13 to 21, 24, 25

RTD (R): 41 to 46, 51 to 54, 63, 64, 67, 68

DC current/voltage (L): 84, 86 to 90

Temperature unit 0: Centigrade (°C)

Cold junction compensation

(T/C)

Decimal point position

1: Fahrenheit (°F)

0: Cold junction compensation is performed. (Internal)

1: Cold junction compensation is not performed.

(External)

0: No decimal point

1: One digit below decimal point

2: Two digits below decimal point

3: Three digits below decimal point

(Select ‘0’ or ‘1’ for the RTD range with decimal point)

PV range low limit When the PV input range type is thermocouple (T) or

RTD (R), the setting is disabled although range low

SP low limit

SP high limit

Squarer root 0.0 to 100.0% extraction dropout (0.0: No square root extraction)

Control action

(direct/reverse)

Selection of MV at PV alarm

0: Heat control (reverse action))

1: Cool control (direct action)

0: Control operation is continued.

1: MV at PV alarm occurrence is outputted.

occurrence

MV at PV alarm –10.0 to +110.0% occurrence

MV at READY (at –10.0 to +110.0% heat-side for heat/cool control)

MV at READY (at –10.0 to +110.0% cool-side)

Operation at 0: Bump-less

MANUAL change 1: Preset

Preset MANUAL –10.0 to +110.0% value

PID operation initialization

(Used even at MANUAL mode when power is ON.)

0: Automatic

1: Not initialized function selection 2: Initialized (when SP value different from current value is inputted.)

–10.0 to +110.0% PID operation initial MV

Heat/cool control 0: Disabled.

1: Enabled.

Heal/cool selection 0: Normal

1: Energy saving

Dead zone –100.0 to +100.0%

Heal/cool control –10.0 to +110.0% selection point

LSP setting system

SP ramp unit

1 to 4

CT1 operation type

CT1 output

0: 0.1U/s

1: 0.1U/min

2: 0.1U/h

0: Heater burnout detection

1: Current value measurement

0: Control output 1

1: Control output 2

2: Event output 1

3: Event output 2

4: Event output 3

CT1 measurement 30 to 300ms wait time

CT2 operation type Same as CT1.

CT2 output

CT2 measurement wait time

Control output 1 1: 4 to 2mA range type

2: 0 to 20mA

Control output 1 0: MV

1: Heat MV

2: Cool MV

3: PV

4: PV before ratio bias filter

5: SP

6: Deviation (PV-SP)

7: CT1 current value

8: CT2 current value

9: Invalid

10: SP+MV

11: PV+MV

Control output 1 –1999 to +9999 scaling low limit (The decimal point position and unit may vary

Control output 1 depending on the control output 1 type.) scaling high limit

Control output 1 0 to 9999

MV scaling The decimal point position and unit are same as for PV.

Control output 2 Same as control output 1.

range

Control output 2 type

Control output 2 –1999 to +9999 scaling low limit (The decimal point position and unit may vary

Control output 2 depending on the control output 2 type.) scaling high limit

Control output 2 0 to 9999

MV scaling The decimal point position and unit are same as for PV.

Initial User value level

1

41

88

0

0

0

limit is displayed.

–1999 to +9999U when the PV input range type is DC voltage/current (L).

When the PV input range type is thermocouple (T) or

RTD(R), the setting is disabled although range high limit is displayed.

PV input range low limit to PV input range high limit

0

–1999 to +9999U when the PV input range type is DC 1000 voltage/current (L).

0

-

1000

0.0

0

0

0.0

0.0

0.0

0

0.0 or

50.0

0

0.0 or

50.0

0

0

0.0

50.0

1

1

0

0

30

0

0

30

1

0

0.0

100.0

200

1

3

0

1000

200

0

0

2

0

0

0

1

1

2

0

2

2

1

1

1

1

2

2

0

1

0

2

0

2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

E3 E6

CP-UM-5410EC

C 67

C 68

C 69

C 70

C 7 1

C 72

C 79

C 80

C 90

C 9 1

C 92

C 93

C 64

Display

C 65

C 66

C 73

C 74

C 75

C 76

C 77

C 78

Item Contents

CPL/MODBUS

Station address

Transmission speed

0: CPL

1: MODBUS ASCII format

2: MODBUS RTU format

0 to 127

Communication is disabled when "0" is set.

0: 4800bps

1: 9600bps

2: 19200bps

3: 38400bps

Data format (data 0: 7bits length)

Data format

(parity)

1: 8bits

0: Even parity

1: Odd parity

2: No parity

Data format (stop 0: 1bit bits)

Communication minimum response time

Key operation

1: 2bits

1 to 250ms mode/type

MODE key function

MODE display setup

0: Standard type

1: Special type

0: Invalid

1: AUTO/MANUAL selection

2: RUN/READY selection

3: AT Stop/Start

4: LSP group selection

5: Release of all DO latches

6: Invalid

7: Communication DI1 selection

8: Invalid

Whether the mode bank setup display is enabled or disabled is determined by the sum of the following weighting:

Bit 0: AUTO/MANUAL display

0: Disabled, +1: Enabled

PV/SP value display setup

Bit 1: RUN/READY display

0: Disabled, +2: Enabled

Bit 3: AT stop/start display

0: Disabled, +8: Enabled

Bit 4: DO latch release

0: Disabled, +16: Enabled

Bit 5: Communication DI1 ON/OFF display

0: Disabled, +32: Enabled

Other invalid setup: 0, +4, +64, +128

Whether the basic display is enabled or disabled is determined by the sum of the following weighting:

Bit 0: PV display

0: Disabled, +1: Enabled

Bit 1: SP display

0: Disabled, +2: Enabled

Bit 2: LSP group No. display

0: Disabled, +4: Enabled

Other invalid setup: 0, +8

MV display setup Whether the basic display is enabled or disabled is determined by the sum of the following weighting:

Bit 0: MV display

0: Disabled, +1: Enabled

Bit 1: Heat MV/cool MV display

0: Disabled, +2: Enabled

Other invalid setup: 0, +4

Event setting value 0: In the operation display mode, the internal event display setup

Bit 3: AT progress display

0: Disabled, +8: Enabled setting value is not displayed.

1: In the operation display mode, the internal event 1 setting value is displayed.

2: In the operation display mode, the internal event 1 to 3 setting value is displayed.

Event remaining 0: In the operation display mode, the ON/OFF delay time display setup to 2 setting value is displayed.

3: In the operation display mode, the internal event 1 remaining time of the internal event is not displayed.

1: In the operation display mode, the ON/OFF delay remaining time of the internal event 1 is displayed.

2: In the operation display mode, the ON/OFF delay remaining time of the internal event 1 to 2 is displayed.

3: In the operation display mode, the ON/OFF delay

CT input current 0: In the operation display mode, the CT current value display setup remaining time of the internal event 1 to 3 is displayed.

User level value is not displayed.

1: In the operation display mode, the CT1 current value is displayed.

2: In the operation display mode, the CT1 to 2 current value is displayed.

0: Basic configuration

1: Standard configuration

2: High function configuration

LED monitor 0: Disabled

1: Flashing at RS-485 communication signal transmission

2: Flashing at RS-485 communication signal receiving

3: OR (logical sum) of all DI status

4: Flashing at READY

Number of CT1 0: 800 turns turns 1 to 40: CT turns divided by 100.

Number of CT1 0: 1 time power wire loops 1 to 6: Number of times

Number of CT2 0: 800 turns turns 1 to 40: CT turns divided by 100.

Number of CT2 0: 1 time power wire loops 1 to 6: Number of times

Initial User value level

0 0

0

2

1

0

0

3

0

1

255

15

15

0

0

0

0

0

8

1

8

1

0

0

0

0

0

2

2

0

1

1

1

1

1

1

0

2

2

2

2

2

(continued on back page)

E6

■ Event assignment bank

Bank selection: EvCF

Display Item

E 1. C 1 to

E5. C 1

E 1. C2 to

E5. C2

E 1. C3 to

E5. C3

Contents

Operation type of 0: No event internal event 1 to 1: PV high limit

5 configuration 1 2: PV low limit

3: PV high/low limit

4: Deviation high limit

5: Deviation low limit

6: Deviation high/low limit

7: Deviation high limit (Final SP reference)

8: Deviation low limit (Final SP reference)

9: Deviation high/low limit (Final SP reference)

10: SP high limit

11: SP low limit

12: SP high/low limit

13: MV high limit

14: MV low limit

15: MV high/low limit

16: CT1 heater burnout/over-current

17: CT1 heater short-circuit

18: CT2 heater burnout/over-current

19: CT2 heater short-circuit

20: Loop diagnosis 1

21: Loop diagnosis 2

22: Loop diagnosis 3

23: Alarm (status)

24: READY (status)

25: MANUAL (status)

26: Invalid

27: During AT execution (status)

28: During SP ramp (status)

29: Control direct action (status)

30: ST execution (status)

31: Invalid

32: Timer (status)

Internal event 1 to Digits are called as 1st digit, 2nd digit, 3rd digit and

5 Configuration 2 4th digit from the right end digit.

1st digit:

Direct/Reverse

0: Direct

1: Reverse

2nd digit: Stand-by 0: None

1: Standby

2: Standby + Standby at SP change

3rd digit: EVENT 0: Continue state at READY 1: Forced OFF

4th digit: Undefined 0

Internal event 1 to Digits are called as 1st digit, 2nd digit, 3rd digit and

5 Configuration 3 4th digit from the right end digit.

1st digit: Alarm OR 0: No event

1: Alarm direct + OR operation

2: Alarm direct + AND operation

3: Alarm reverse + OR operation

4: Alarm reverse + AND operation

2nd digit: Special 0: As normal execution

OFF

3rd digit: Delay time unit

4th digit:

Undefined

1: Event OFF at the event setting value (main)=0

0: 0.1s

1: 1s

2: 1min

0

Initial User value level

0 0

0000

0

0

0

0

0000

0

0

0

0

0

2

■ DI assignment bank

Bank selection: dI

Display Item dI 1. 1 to dI3. 1 dI 1. 2 to dI3. 2

Contents

Internal contact 1 0: No function to 3

Operation type

1: LSP group selection (0/+1)

2: LSP group selection (0/+2)

3: LSP group selection (0/+4)

4: Invalid

5: Invalid

6: Invalid

7: RUN/READY selection

8: AUTO/MANUAL selection

9: Invalid

10: AT Stop/Start

11: ST Disabled/Enabled

12: Control action direct/reverse selection (As per setting/opposite operation of setting)

13: SP ramp Enabled/Disabled

14: PV hold (No-hold/Hold)

15: PV maximum value hold (No-hold/Hold)

16: PV minimum value hold (No-hold/Hold)

17: Timer Stop/Start

18: Release of all DO latches (Continue/Release)

19: Invalid

20: Invalid

Internal contact 1 0: Disabled. (Input of default) to 3 1: Function 1 ((A and B) or (C and D))

Input bit operation 2: Function 2 ((A or B) and (C or D))

3: Function 3 (A or B or C or D)

4: Function 4 (A and B and C and D)

Initial User value level

0 0

0 2

Display dI 1. 3 to dI3. 3 dI 1. 4 dI3. 4 dI 1. 5 dI3. 5 dI 1. 6 dI3. 6 dI 1. 7 dI3. 7 dI 1. 8 dI3. 8 dI 1. 9 dI3. 9 to to to to to to

Item Contents

Internal contact 0: Normally open (OFF, 0)

1 to 3 1: Normally close (ON, 1)

Input assignment A 2: DI1

3: DI2

4 to 9: Undefined

10: Internal event 1

11: Internal event 2

Internal contact 12: Internal event 3

1 to 3 13: Internal event 4

Input assignment B 14: Internal event 5

15 to 17: Undefined

18: Communication DI1

19: Communication DI2

20: Communication DI3

Internal contact

1 to 3

21: Communication DI4

22: MANUAL mode

Input assignment C 23: READY mode

24: Undefined

25: During AT execution

26: During SP ramp

27: Undefined

28: Alarm is enabled.

Internal contact

1 to 3 29: PV alarm is enabled.

Input assignment D 30: Undefined

31: Mode key function selection status

32: Event output 1 status

33: Control output 1 status

Internal contact

1 to 3

Digits are called as 1st digit, 2nd digit, 3rd digit and

4th digit from the right end digit.

Polarity A to D

1st digit: Polarity A 0: Direct

1: Reverse (Polarity of input assignment A)

2nd digit: Polarity B

(Polarity of input assignment B)

3rd digit: Polarity C

(Polarity of input assignment C)

4th digit: Polarity D

(Polarity of input assignment D)

Internal contact

1 to 3 Polarity

Internal contact

1 to 3

Internal event

No.assignment

0: Direct

1: Reverse

0: Every internal event

1 to 5: Internal event numbers

Initial User value level

2 to 4 2

0

0

0

0000

0

0

0

0

0

0

2

2

2

2

2

2

■ DO assignment bank

Bank selection: dO

Display Item

Ot 1. 1 to

Ot2. 1

Ev 1. 1 to

Ev3. 1

Ot 1. 2 to

Ot2. 2

Ev 1. 2 to

Ev3. 2

Ot 1. 3 to

Ot2. 3

Ev 1. 3 to

Ev3. 3

Ot 1. 4 to

Ot2. 4

Ev 1. 4 to

Ev3. 4

Ot 1. 5 to

Ot2. 5

Ev 1. 5 to

Ev3. 5

Contents

Control output 0: Input of default

1 to 2, event output 1: MV1 (ON/OFF control output, time proportional

1 to 3 operation type output,heat-side proportional output of heat/cool control)

2: MV2 (cool-side proportional output of heat/cool control)

3: Function 1 ((A and B) or (C and D))

4: Function 2 ((A or B) and (C or D))

5: Function 3 (A or B or C or D)

6: Function 4 (A and B and C and D)

Control output 0: Normally open (OFF, 0)

1 to 2, event output 1: Normally close (ON, 1)

1 to 3 output assignment A

2: Internal event 1

3: Internal event 2

4: Internal event 3

5: Internal event 4

6: Internal event 5

7 to 13: Undefined

14: MV1

15: MV2 Control output

1 to 2, event output 16 to 17: Undefined

1 to 3 output assignment B

18: DI1

19: DI2

20 to 25: Undefined

26: Internal contact 1

27: Internal contact 2

28: Internal contact 3

29 to 33: Undefined

34: Communication DI1 Control output

1 to 2, event output 35: Communication DI2

1 to 3 output assignment C

36: Communication DI3

37: Communication DI4

38: MANUAL mode

39: READY mode

40: Invalid

41: During AT execution

42: During SP ramp

43: Undefined Control output

1 to 2 event output 44: Alarm is enabled.

1 to 3 output assignment D

45: PV alarm is enabled.

46: Undefined

47: mode key function selection status

48: Event output 1 status

49: Control output 1 status

Initial User value level

0 2

14 to 15 or

2 to 4

0

0

0

2

2

2

2

Display

Ot 1. 6 to

Ot2. 6

Ev 1. 6 to

Ev3. 6

Ot 1. 7

Ot2. 7

Ev 1. 7

Ev3. 7

Ot 1. 8

Ot2. 8 to

Ev 1. 8 to

Ev3. 8 to to

Item Contents

Control output 1 to Digits are called as 1st digit, 2nd digit, 3rd digit and

2, event output 1 to 4th digit from the right end digit.

2 Polarity A to D

1st digit: Polarity A 0: Direct

2nd digit: Polarity B 1: Reverse

3rd digit: Polarity C

4th digit: Polarity D

Control output 1 0: Direct to 2, event output 1: Reverse

1 to 3

Polarity

Control output 1 0: Disabled to 2, event output 1: Enabled (Latch at ON)

1 to 3

Latch

2: Enabled (Latch at OFF, except at the time of initialization after power ON)

Initial User value level

0000 2

0

0

0

0

0 2

0 2

■ User function bank

Bank selection: UF

Display Item

UF- 1

UF-2

UF-3

UF-4

UF-5

UF-6

UF-7

UF-8

User function definition 1

User function definition 2

User function definition 3

User function definition 4

User function definition 5

User function definition 6

User function definition 7

User function definition 8

Contents

This is the display in upper display. The setup exception is as follows:

---: Yet to be registered.

P-: Proportional band of the PID group in use

I-: Integration time of the PID group in use d-: Derivative time of the PID group in use rE-: Manual reset of the PID group in use

OL-: MV low limit of the PID group in use

OH-: MV high limit of the PID group in use

P--C : Cool-side proportional band of the PID group in use

I--C : Cool-side integration time of the PID group in use d--C : Cool-side derivative time of the PID group in use

Ol.-C : Cool-side MV low limit of the PID group in use

Oh.-C : Cool-side of MV high limit of the PID group in use

- - - -

- - - -

- - - -

- - - -

- - - -

Initial User value level

- - - 1

- - - -

- - - -

1

1

1

1

1

1

1

■ Lock bank

Bank selection: LOC

Display Item

LOC

C. LOC

L. LOC

PASS

PS 1A

PS2A

PS 1b

PS2b

Contents

Key lock

Communication lock

Loader lock

0: All settings are enabled.

1: Mode, event, operation display, SP, UF, lock, manual MV, and mode key can be set.

2: Operation display, SP, UF, lock, manual MV, and mode key can be set.

3: UF, lock, manual MV, and mode key can be set.

Password display 0 to 15

5: Password 1A to 2B display

Password 1A

Password 2A

Password 1B

Password 2B

0: RS-485 communication read/write is enabled.

1: RS-485 communication read/write is disabled.

0: Loader communication read/write is enabled.

1: Loader communication read/write is disabled.

0000 to FFFF (hexadecimal value)

0000 to FFFF (hexadecimal value)

0000 to FFFF (hexadecimal value)

0000 to FFFF (hexadecimal value)

Initial User value level

0 0

0

0

0

0000

0000

0000

0000

0

0

0

0

0

2

2

■ Instrument information bank

Bank selection: Id

Display Item

Id0 1

Id02

Id03

Id04

Id05

Id06

Id07

Id08

Contents

ROM ID

ROM version 1

ROM version 2

SLP support

Information

EST support version

Manufacturing date code (year)

0: fixed

XX. XX (2 digits after decimal point)

XX. XX (2 digits after decimal point)

Year - 2000

Ex.: “3” means the year 2003.

Manufacturing Month + Day 100 date code (month, Ex.: “12.01” means the 1st day of December day)

Serial No.

Initial User value level

-

-

-

2

2

2

2

-

2

2

2

2

E7 E4

1st edition: Mar. 2006

13th edition: Mar. 2015 (F)

■ Event assignment bank

Bank selection: EvCF

Display Item

E 1. C 1 to

E5. C 1

E 1. C2 to

E5. C2

E 1. C3 to

E5. C3

Contents

Operation type of 0: No event internal event 1 to 1: PV high limit

5 configuration 1 2: PV low limit

3: PV high/low limit

4: Deviation high limit

5: Deviation low limit

6: Deviation high/low limit

7: Deviation high limit (Final SP reference)

8: Deviation low limit (Final SP reference)

9: Deviation high/low limit (Final SP reference)

10: SP high limit

11: SP low limit

12: SP high/low limit

13: MV high limit

14: MV low limit

15: MV high/low limit

16: CT1 heater burnout/over-current

17: CT1 heater short-circuit

18: CT2 heater burnout/over-current

19: CT2 heater short-circuit

20: Loop diagnosis 1

21: Loop diagnosis 2

22: Loop diagnosis 3

23: Alarm (status)

24: READY (status)

25: MANUAL (status)

26: Invalid

27: During AT execution (status)

28: During SP ramp (status)

29: Control direct action (status)

30: ST execution (status)

31: Invalid

32: Timer (status)

Internal event 1 to Digits are called as 1st digit, 2nd digit, 3rd digit and

5 Configuration 2 4th digit from the right end digit.

1st digit:

Direct/Reverse

0: Direct

1: Reverse

2nd digit: Stand-by 0: None

1: Standby

2: Standby + Standby at SP change

3rd digit: EVENT 0: Continue state at READY 1: Forced OFF

4th digit: Undefined 0

Internal event 1 to Digits are called as 1st digit, 2nd digit, 3rd digit and

5 Configuration 3 4th digit from the right end digit.

1st digit: Alarm OR 0: No event

1: Alarm direct + OR operation

2: Alarm direct + AND operation

3: Alarm reverse + OR operation

4: Alarm reverse + AND operation

2nd digit: Special 0: As normal execution

OFF

3rd digit: Delay time unit

4th digit:

Undefined

1: Event OFF at the event setting value (main)=0

0: 0.1s

1: 1s

2: 1min

0

Initial User value level

0 0

0000

0

0

0

0

0000

0

0

0

0

0

2

■ DI assignment bank

Bank selection: dI

Display Item dI 1. 1 to dI3. 1 dI 1. 2 to dI3. 2

Contents

Internal contact 1 0: No function to 3

Operation type

1: LSP group selection (0/+1)

2: LSP group selection (0/+2)

3: LSP group selection (0/+4)

4: Invalid

5: Invalid

6: Invalid

7: RUN/READY selection

8: AUTO/MANUAL selection

9: Invalid

10: AT Stop/Start

11: ST Disabled/Enabled

12: Control action direct/reverse selection (As per setting/opposite operation of setting)

13: SP ramp Enabled/Disabled

14: PV hold (No-hold/Hold)

15: PV maximum value hold (No-hold/Hold)

16: PV minimum value hold (No-hold/Hold)

17: Timer Stop/Start

18: Release of all DO latches (Continue/Release)

19: Invalid

20: Invalid

Internal contact 1 0: Disabled. (Input of default) to 3 1: Function 1 ((A and B) or (C and D))

Input bit operation 2: Function 2 ((A or B) and (C or D))

3: Function 3 (A or B or C or D)

4: Function 4 (A and B and C and D)

Initial User value level

0 0

0 2

Display dI 1. 3 to dI3. 3 dI 1. 4 dI3. 4 dI 1. 5 dI3. 5 dI 1. 6 dI3. 6 dI 1. 7 dI3. 7 dI 1. 8 dI3. 8 dI 1. 9 dI3. 9 to to to to to to

Item Contents

Internal contact 0: Normally open (OFF, 0)

1 to 3 1: Normally close (ON, 1)

Input assignment A 2: DI1

3: DI2

4 to 9: Undefined

10: Internal event 1

11: Internal event 2

Internal contact 12: Internal event 3

1 to 3 13: Internal event 4

Input assignment B 14: Internal event 5

15 to 17: Undefined

18: Communication DI1

19: Communication DI2

20: Communication DI3

Internal contact

1 to 3

21: Communication DI4

22: MANUAL mode

Input assignment C 23: READY mode

24: Undefined

25: During AT execution

26: During SP ramp

27: Undefined

28: Alarm is enabled.

Internal contact

1 to 3 29: PV alarm is enabled.

Input assignment D 30: Undefined

31: Mode key function selection status

32: Event output 1 status

33: Control output 1 status

Internal contact

1 to 3

Digits are called as 1st digit, 2nd digit, 3rd digit and

4th digit from the right end digit.

Polarity A to D

1st digit: Polarity A 0: Direct

1: Reverse (Polarity of input assignment A)

2nd digit: Polarity B

(Polarity of input assignment B)

3rd digit: Polarity C

(Polarity of input assignment C)

4th digit: Polarity D

(Polarity of input assignment D)

Internal contact

1 to 3 Polarity

Internal contact

1 to 3

Internal event

No.assignment

0: Direct

1: Reverse

0: Every internal event

1 to 5: Internal event numbers

Initial User value level

2 to 4 2

0

0

0

0000

0

0

0

0

0

0

2

2

2

2

2

2

■ DO assignment bank

Bank selection: dO

Display Item

Ot 1. 1 to

Ot2. 1

Ev 1. 1 to

Ev3. 1

Ot 1. 2 to

Ot2. 2

Ev 1. 2 to

Ev3. 2

Ot 1. 3 to

Ot2. 3

Ev 1. 3 to

Ev3. 3

Ot 1. 4 to

Ot2. 4

Ev 1. 4 to

Ev3. 4

Ot 1. 5 to

Ot2. 5

Ev 1. 5 to

Ev3. 5

Contents

Control output 0: Input of default

1 to 2, event output 1: MV1 (ON/OFF control output, time proportional

1 to 3 operation type output,heat-side proportional output of heat/cool control)

2: MV2 (cool-side proportional output of heat/cool control)

3: Function 1 ((A and B) or (C and D))

4: Function 2 ((A or B) and (C or D))

5: Function 3 (A or B or C or D)

6: Function 4 (A and B and C and D)

Control output 0: Normally open (OFF, 0)

1 to 2, event output 1: Normally close (ON, 1)

1 to 3 output assignment A

2: Internal event 1

3: Internal event 2

4: Internal event 3

5: Internal event 4

6: Internal event 5

7 to 13: Undefined

14: MV1

15: MV2 Control output

1 to 2, event output 16 to 17: Undefined

1 to 3 output assignment B

18: DI1

19: DI2

20 to 25: Undefined

26: Internal contact 1

27: Internal contact 2

28: Internal contact 3

29 to 33: Undefined

34: Communication DI1 Control output

1 to 2, event output 35: Communication DI2

1 to 3 output assignment C

36: Communication DI3

37: Communication DI4

38: MANUAL mode

39: READY mode

40: Invalid

41: During AT execution

42: During SP ramp

43: Undefined Control output

1 to 2 event output 44: Alarm is enabled.

1 to 3 output assignment D

45: PV alarm is enabled.

46: Undefined

47: mode key function selection status

48: Event output 1 status

49: Control output 1 status

Initial User value level

0 2

14 to 15 or

2 to 4

0

0

0

2

2

2

2

Display

Ot 1. 6 to

Ot2. 6

Ev 1. 6 to

Ev3. 6

Ot 1. 7

Ot2. 7

Ev 1. 7

Ev3. 7

Ot 1. 8

Ot2. 8 to

Ev 1. 8 to

Ev3. 8 to to

Item Contents

Control output 1 to Digits are called as 1st digit, 2nd digit, 3rd digit and

2, event output 1 to 4th digit from the right end digit.

2 Polarity A to D

1st digit: Polarity A 0: Direct

2nd digit: Polarity B 1: Reverse

3rd digit: Polarity C

4th digit: Polarity D

Control output 1 0: Direct to 2, event output 1: Reverse

1 to 3

Polarity

Control output 1 0: Disabled to 2, event output 1: Enabled (Latch at ON)

1 to 3

Latch

2: Enabled (Latch at OFF, except at the time of initialization after power ON)

Initial User value level

0000 2

0

0

0

0

0 2

0 2

■ User function bank

Bank selection: UF

Display Item

UF- 1

UF-2

UF-3

UF-4

UF-5

UF-6

UF-7

UF-8

User function definition 1

User function definition 2

User function definition 3

User function definition 4

User function definition 5

User function definition 6

User function definition 7

User function definition 8

Contents

This is the display in upper display. The setup exception is as follows:

---: Yet to be registered.

P-: Proportional band of the PID group in use

I-: Integration time of the PID group in use d-: Derivative time of the PID group in use rE-: Manual reset of the PID group in use

OL-: MV low limit of the PID group in use

OH-: MV high limit of the PID group in use

P--C : Cool-side proportional band of the PID group in use

I--C : Cool-side integration time of the PID group in use d--C : Cool-side derivative time of the PID group in use

Ol.-C : Cool-side MV low limit of the PID group in use

Oh.-C : Cool-side of MV high limit of the PID group in use

- - - -

- - - -

- - - -

- - - -

- - - -

Initial User value level

- - - 1

- - - -

- - - -

1

1

1

1

1

1

1

■ Lock bank

Bank selection: LOC

Display Item

LOC

C. LOC

L. LOC

PASS

PS 1A

PS2A

PS 1b

PS2b

Contents

Key lock

Communication lock

Loader lock

0: All settings are enabled.

1: Mode, event, operation display, SP, UF, lock, manual MV, and mode key can be set.

2: Operation display, SP, UF, lock, manual MV, and mode key can be set.

3: UF, lock, manual MV, and mode key can be set.

Password display 0 to 15

5: Password 1A to 2B display

Password 1A

Password 2A

Password 1B

Password 2B

0: RS-485 communication read/write is enabled.

1: RS-485 communication read/write is disabled.

0: Loader communication read/write is enabled.

1: Loader communication read/write is disabled.

0000 to FFFF (hexadecimal value)

0000 to FFFF (hexadecimal value)

0000 to FFFF (hexadecimal value)

0000 to FFFF (hexadecimal value)

Initial User value level

0 0

0

0

0

0000

0000

0000

0000

0

0

0

0

0

2

2

■ Instrument information bank

Bank selection: Id

Display Item

Id0 1

Id02

Id03

Id04

Id05

Id06

Id07

Id08

Contents

ROM ID

ROM version 1

ROM version 2

SLP support

Information

EST support version

Manufacturing date code (year)

0: fixed

XX. XX (2 digits after decimal point)

XX. XX (2 digits after decimal point)

Year - 2000

Ex.: “3” means the year 2003.

Manufacturing Month + Day 100 date code (month, Ex.: “12.01” means the 1st day of December day)

Serial No.

Initial User value level

-

-

-

2

2

2

2

-

2

2

2

2

E4 E8

1st edition: Mar. 2006

13th edition: Mar. 2015 (F)

CP-UM-5410EC ( 不适用于日本 )

数字显示调节器

C15M

使用说明书 设置篇

感谢您购买阿自倍尔株式会社产品。

为了正确、安全的使用本产品,请务必阅读本使用说明书,在阅读、理解

本书的基础上进行使用。

在订购及使用产品之际,请务必登入以下网站,浏览“产品订购注意事项”。 http://www.azbil.com/cn/products/order.html

中英文版的内容如有差异,以英文版为准。

要求

请确保把本使用说明书送到本产品使用者手中。

禁止擅自复印和转载全部或部分本使用说明书的内容。

今后内容变更时恕不事先通知。

本使用说明书的内容经过仔细审查校对,万一有错误和遗漏,请向本公司

提出。

对客户应用结果,本公司有不能承担责任的场合,敬请谅解。

©2006-2015 Azbil Corporation All Rights Reserved.

本书对使用上的注意事项和安装、接线、 PV 量程种类、参数一览、主要规

格等进行说明。

请确认

您购买的 C15MT 含有以下物品

安装件

密封垫

使用说明书 ( 本书

本 ) CP-UM-5410EC 1

C1

安全注意事项

警告 错误使用时,可能会造成使用者死亡或负重伤的危

险状态。

注意 错误使用时,可能会发生使用者负轻伤或造成物品

损坏的危险状态。

警告

本机的接线错误会造成故障或产生危险灾害。

本机在通电前,请务必确认接线是否正确。

本机的接线或安装、拆卸时,请务必在切断电源的情况下进行。

请勿触摸电源端子等受电体。

否则可能会触电。

请勿分解本机。

否则可能会触电及产生故障。

注意

请在规格规定的使用条件 ( 温度、湿度、电压、振动、冲击、安装

方向、环境等 ) 范围内使用本机。

否则可能会引起火灾、产生故障。

请勿遮盖本机的通风口。

否则可能会引起火灾或产生故障。

请按照规定的基准、指定的电源及施工方法进行正确配线。

否则可能会引起火灾、触电、故障。

避免线头、切削粉、水等进入本机内部。

否则可能发生火灾、故障。

请按照端子螺丝规格中记载的扭矩切实拧紧螺丝。

如果紧固不充分,可能会触电、引起火灾。

请勿把本机未使用端子作为中继端子使用。

否则可能会触电、发生火灾、产生故障。

本机接线后建议盖上端子盖。

否则可能会触电。 ( 本机的端子盖是另售品 )

请按规格中记载的寿命范围内使用本机的继电器。

过度使用后可能引起火灾、产生故障。

有雷浪涌的场合,请使用本公司生产的浪涌吸收器。

否则可能会引起火灾、产生故障。

请勿用头部尖锐的物品 ( 铅笔尖或针等 ) 操作键。

否则会产生故障。

C1

设 置

■ 安装场所

请把本机设置在如下场所。

• 除供给电源及继电器接点输出外,输入输出模件的共模电压:

对大地间的电压为 30Vr.m.s.

以下,峰值 42.4

以下, DC60V 以下。

• 无高温﹑低温﹑高湿度﹑低湿度的场所。

• 无硫化气等腐蚀性气体及硅气体的场所。

• 粉尘﹑油烟较少的场所。

• 无直射阳光及风雨不能直接触及的场所。

• 机械振动﹑冲击少的场所。

• 远离高压线﹑焊接机附近及电气干扰发生源附近的场所。

• 远离如锅炉等有高压点火装置 15m 以上的场所。

• 受电磁干扰少的场所

• 无可燃性液体或蒸汽的场所

• 室内

■ 安装方法

• 安装角度从水平位置向后仰 10 度以内﹑向前倾 10 度以内。

• 仪表盘安装型 (C15MT) 的场合,请使用板厚在 9mm 以下的钢板。

■ 外型尺寸

● C15MT( 盘安装型 )

2 60

安装件(附属品)

( 单位: mm)

端子螺丝

M3 48

SDC15 pv sp mode rdy man para ev1 ev2 ev3 ot1 ot2

使用上的注意事项

拧紧附属的安装件螺丝,直到安装件不再活动后再拧 1 圈螺丝,固

定在仪表盘上。

请勿将螺丝拧得过紧,否则会使机箱变形。

● 盘开孔图

单台安装

30 以上 .

45

密集安装

(48xN -3) +0.5

0

( 单位: mm)

(N 为安装台数 )

使用上的注意事项

• 3 台以上横向密集安装的场合,环境温度不要超过 40 ℃。

• 需要防水、防尘的场合,请单台安装。 已经密集安装的场合,不

能保证防水、防尘性能。

• 上下方向保持 50mm 以上的间隔。

接 线

进行仪表电源配线时,请将本产品的主电源切断开关设置在操作员手能触

及的范围内。

另外,进行 AC 电源型的仪表电源配线时,请配上滞后型 (T) 额定电流 0.2A

额定电压 250V 的保险丝。 (IEC127)

仪表侧面的端子配列标号的含义如下表所示。

记 号

~ 交流

注意、触电的危险

注意

使用上的注意事项

• 请在确认贴在本机侧面的仪表型号与端子编号后进行接线。

接线完毕后,请务必确认接线无误。

• 输入输出信号线远离动力线或电源线 50cm 以上,而且不能在同

一配线管或线槽内。

• 请注意压接端子等不能与相邻的端子接触。

• 1 个端子螺丝连接多个压接端子的场合,请事先把压

接端子弯曲处理并连接不超过 2 个压接端子。

• 1 ~ 6, 13 ~ 18 号端子的配线请从端子台侧看的左方向进行配线。

• 端子连接时请使用适合 M3 螺丝的下述尺寸的端子。

B

A : 5.8mm

以下 B : 5.5

~ 7.6mm

(参考)推荐压接端子:日本压接端子制造 ( 株 )

V1.25-MS3

• 仪表电源为 OFF 时 , 电流输入回路被断开。当计装设计需数台仪表

的电流输入串联时 , 请配上另售的电阻 (81401325), 取其电压作为

电压量程使用。

• 请把流过加热电流的导线贯通在电流互感器中。同时,请勿在超

过规格中规定的容许电流的情况下使用。否则会损坏本机。

• 本机在电源投入后进入稳定状态前,最长 6s 内不动作。其后进入

运行状态,但为了保证规定的精度,请预热 30 分钟以上。

• 电流互感器输入不能用于位相控制。

• 控制输出 1 与控制输出 2 之间未隔离。请根据需要进行隔离。

• RS-485 的通信路的两端上请勿连接终端电阻。否则不能通讯。

• 与本机连接的机器或装置,需采取与本机的电源、输入输出部的

最高使用电压适合的强化绝缘措施后,才能使用。

● C15MT 的接线

继电器

电压脉冲

控制输出

1

2

3

1

2

电流

热电偶

热电阻

电流

电压

1

2

PV 输入

+

4

5

6

C

B

A mA

V

+

-

+

4

5

6

4

5

6

4

5

6

1

2

3

16

17

18

13

14

15

10

11

12

7

8

9

CT 输入

CT1

CT2

13

14

15

事件输出

9

10

7

8

1

2

3

电源

11

12

继电器

AC 电源

100 ~ 240Vac

DA

DB

SG

2

DI/ 通讯

1

16

17

18

16

17

18

数字输入

RS-485

通讯

● 输入输出间隔离

实线围住部分与其它信号隔离。

有无输入输出根据型号决定。

电源

PV 输入

CT 输入 1

CT 输入 2

编程器通讯

数字输入 1

数字输入 2

RS-485 通讯

内部回路

控制输出 1

控制输出 2

事件输出 1( 注 )

事件输出 2( 注 )

事件输出 3

CP-UM-5410EC ( 不适用于日本 )

数字显示调节器

C15M

使用说明书 设置篇

感谢您购买阿自倍尔株式会社产品。

为了正确、安全的使用本产品,请务必阅读本使用说明书,在阅读、理解

本书的基础上进行使用。

在订购及使用产品之际,请务必登入以下网站,浏览 “ 产品订购注意事项 ” 。 http://www.azbil.com/cn/products/order.html

中英文版的内容如有差异,以英文版为准。

要求

请确保把本使用说明书送到本产品使用者手中。

禁止擅自复印和转载全部或部分本使用说明书的内容。

今后内容变更时恕不事先通知。

本使用说明书的内容经过仔细审查校对,万一有错误和遗漏,请向本公司

提出。

对客户应用结果,本公司有不能承担责任的场合,敬请谅解。

©2006-2015 Azbil Corporation All Rights Reserved.

本书对使用上的注意事项和安装、接线、 PV 量程种类、参数一览、主要规

格等进行说明。

请确认

您购买的 C15MT 含有以下物品

安装件

密封垫

使用说明书 ( 本书

本 ) CP-UM-5410EC 1

警告

注意

安全注意事项

错误使用时,可能会造成使用者死亡或负重伤的危

险状态。

错误使用时,可能会发生使用者负轻伤或造成物品

损坏的危险状态。

警告

本机的接线错误会造成故障或产生危险灾害。

本机在通电前,请务必确认接线是否正确。

本机的接线或安装、拆卸时,请务必在切断电源的情况下进行。

请勿触摸电源端子等受电体。

否则可能会触电。

请勿分解本机。

否则可能会触电及产生故障。

注意

请在规格规定的使用条件 ( 温度、湿度、电压、振动、冲击、安装

方向、环境等 ) 范围内使用本机。

否则可能会引起火灾、产生故障。

请勿遮盖本机的通风口。

否则可能会引起火灾或产生故障。

请按照规定的基准、指定的电源及施工方法进行正确配线。

否则可能会引起火灾、触电、故障。

避免线头、切削粉、水等进入本机内部。

否则可能发生火灾、故障。

请按照端子螺丝规格中记载的扭矩切实拧紧螺丝。

如果紧固不充分,可能会触电、引起火灾。

请勿把本机未使用端子作为中继端子使用。

否则可能会触电、发生火灾、产生故障。

本机接线后建议盖上端子盖。

否则可能会触电。 ( 本机的端子盖是另售品 )

请按规格中记载的寿命范围内使用本机的继电器。

过度使用后可能引起火灾、产生故障。

有雷浪涌的场合,请使用本公司生产的浪涌吸收器。

否则可能会引起火灾、产生故障。

请勿用头部尖锐的物品 ( 铅笔尖或针等 ) 操作键。

否则会产生故障。

C1

■ 安装场所

请把本机设置在如下场所。

• 除供给电源及继电器接点输出外,输入输出模件的共模电压:

对大地间的电压为 30Vr.m.s.

以下,峰值 42.4

以下, DC60V 以下。

• 无高温﹑低温﹑高湿度﹑低湿度的场所。

• 无硫化气等腐蚀性气体及硅气体的场所。

• 粉尘﹑油烟较少的场所。

• 无直射阳光及风雨不能直接触及的场所。

• 机械振动﹑冲击少的场所。

• 远离高压线﹑焊接机附近及电气干扰发生源附近的场所。

• 远离如锅炉等有高压点火装置 15m 以上的场所。

• 受电磁干扰少的场所

• 无可燃性液体或蒸汽的场所

• 室内

■ 安装方法

• 安装角度从水平位置向后仰 10 度以内﹑向前倾 10 度以内。

• 仪表盘安装型 (C15MT) 的场合,请使用板厚在 9mm 以下的钢板。

■ 外型尺寸

● C15MT( 盘安装型 )

48

SDC15 pv sp mode rdy man para ev1 ev2 ev3 ot1 ot2

使用上的注意事项

拧紧附属的安装件螺丝,直到安装件不再活动后再拧 1 圈螺丝,固

定在仪表盘上。

请勿将螺丝拧得过紧,否则会使机箱变形。

● 盘开孔图

单台安装

30 以上 .

45

2

设 置

60

安装件(附属品)

密集安装

( 单位: mm)

(48xN -3) +0.5

0

(N 为安装台数 )

( 单位: mm)

使用上的注意事项

• 3 台以上横向密集安装的场合,环境温度不要超过 40 ℃。

• 需要防水、防尘的场合,请单台安装。 已经密集安装的场合,不

能保证防水、防尘性能。

• 上下方向保持 50mm 以上的间隔。

C2

接 线

进行仪表电源配线时,请将本产品的主电源切断开关设置在操作员手能触

及的范围内。

另外,进行 AC 电源型的仪表电源配线时,请配上滞后型 (T) 额定电流 0.2A

额定电压 250V 的保险丝。 (IEC127)

仪表侧面的端子配列标号的含义如下表所示。

记 号

~ 交流

注意、触电的危险

注意

使用上的注意事项

• 请在确认贴在本机侧面的仪表型号与端子编号后进行接线。

接线完毕后,请务必确认接线无误。

• 输入输出信号线远离动力线或电源线 50cm 以上,而且不能在同

一配线管或线槽内。

• 请注意压接端子等不能与相邻的端子接触。

• 1 个端子螺丝连接多个压接端子的场合,请事先把压

接端子弯曲处理并连接不超过 2 个压接端子。

• 1 ~ 6, 13 ~ 18 号端子的配线请从端子台侧看的左方向进行配线。

• 端子连接时请使用适合 M3 螺丝的下述尺寸的端子。

B

A : 5.8mm

以下 B : 5.5

~ 7.6mm

(参考)推荐压接端子:日本压接端子制造 ( 株 )

V1.25-MS3

• 仪表电源为 OFF 时 , 电流输入回路被断开。当计装设计需数台仪表

的电流输入串联时 , 请配上另售的电阻 (81401325), 取其电压作为

电压量程使用。

• 请把流过加热电流的导线贯通在电流互感器中。同时,请勿在超

过规格中规定的容许电流的情况下使用。否则会损坏本机。

• 本机在电源投入后进入稳定状态前,最长 6s 内不动作。其后进入

运行状态,但为了保证规定的精度,请预热 30 分钟以上。

• 电流互感器输入不能用于位相控制。

• 控制输出 1 与控制输出 2 之间未隔离。请根据需要进行隔离。

• RS-485 的通信路的两端上请勿连接终端电阻。否则不能通讯。

• 与本机连接的机器或装置,需采取与本机的电源、输入输出部的

最高使用电压适合的强化绝缘措施后,才能使用。

● C15MT 的接线

继电器

电压脉冲

控制输出

1

2

3

1

2

电流

热电偶

热电阻

电流

电压

1

2

PV 输入

+

4

5

6

C

B

A mA

V

+

-

+

4

5

6

4

5

6

4

5

6

1

2

3

16

17

18

13

14

15

10

11

12

7

8

9

CT 输入

CT1

CT2

13

14

15

事件输出

7

8

9

10

1

2

3

电源

11

12

继电器

AC 电源

100 ~ 240Vac

DA

DB

SG

2

DI/ 通讯

1

16

17

18

16

17

18

数字输入

RS-485

通讯

● 输入输出间隔离

实线围住部分与其它信号隔离。

有无输入输出根据型号决定。

电源

PV 输入

CT

输入

1

CT 输入 2

编程器通讯

数字输入 1

数字输入 2

RS-485

通讯

内部回路

控制输出 1

控制输出 2

事件输出 1( 注 )

事件输出 2( 注 )

事件输出 3

C2

各部件的名称和功能

SDC15

SDC15 pv

④ sp mode rdy man ev1 ev2 para ev3 ot1 ot2

⑤ ⑥

① 第 1 显示部:

② 第 2 显示部:

显示 PV 值 ( 现在的温度等 ) 或设定项目。

显示 SP 值 ( 设定温度值等 ) 或各设定项目的设定

值。

③ 模式显示灯 rdy : READY 模式 ( 控制停止 ) 时灯亮 man : MANUAL 模式 ( 手动 ) 时灯亮 ev1 ~ ev3 : 事件继电器输出 ON 时灯亮

④ [mode] 键: ot1 ~ ot2 : 控制输出为

连续按键 1s

ON 时灯亮

以上时可进行预先设定的操作。

出厂时设定为 RUN/READY 切换。

⑤ [para] 键:

⑥ <、∨、∧键:

显示切换。

数值增减、位变更时使用。

⑦ 编程器插口: 使用智能编程器软件包同包装的专用电缆与计

算机连接。

键操作和设定

下图表示键操作的流程。各种显示或设定可以从面板上调出。

电源投入时显示 pv sp mode rdy man ev1 ev2 ev3 ot1 ot2 para

灯灭

灯灭

模式显示灯从左依

次灯亮

电源投入后 6s 内,第 1 显示部、第 2 显示部保持灯灭状态,

模式显示灯从左依次灯亮。如果所有的灯亮,则切换到运行

显示。

运行显示 pv sp mode

PV/SP 显示

按 para 键 pv sp mode

MV 显示

按 para 键

(

其它显示、设定

重复 para 键操作 )

按 para 键

2s 以上

3min 以上不进行键操作

mode

按 para 键

2s 以上

参数设定显示 pv sp mode

AUTO/MANUAL 切换

按 para 键 pv sp mode

RUN/READY 切换

按 para 键

其它设定

( 重复 para 键操作 )

3min 以上不进行键操作

mode

按 para 键 2s pv sp mode

PV 量程种类设定

按 para 键 pv sp mode

温 度 单 位 设 定

按 para 键

其它设定

( 重复 para 键操作 )

以上

设置数据设定显示

按 para 键 按 para 键 按 para 键

此图中描写的显示或设定状态是说明用的例子。

实际中根据型号或设定内容,显示或设定可能不显示。

C3

● PV 输入量程的设定

设定显示「 C01 」下按 [ < ] 、 [ ∨ ] 、 [ ∧ ] 键,在第 2 显示部上设定希望

的 PV 量程种类。

不需按键 , 只要经过 2s 以上时 , 闪烁将停止, PV 量程种类的设定完

成。

● SP 的设定

运行显示的 PV/SP 显示中按 [ < ] 、 [ ∨ ] 、 [ ∧ ] 键 , 变更第 2 显示部的

SP 。

不需按键 , 只要经过 2s 以上时 , 数值闪烁将停止,确定设定值。

SP 在参数设定显示下也可以设定。

C01 编号 传感器类型

1 K

2 K

3

4

K

K

5

6

K

K

9

10

11

13

14

15

16

J

J

J

E

T

R

S

B 17

18

19

20

N

PL II

WRe5-26

21

24

25

WRe5-26

DIN U

DIN L

量程

- 200 ~+ 1200 ℃

0 ~ 1200 ℃

0.0

~ 800.0

0.0

~ 600.0

0.0

~ 400.0

- 200.0

~+ 400.0

0.0

~ 800.0

0.0

~ 600.0

- 200.0

~+ 400.0

0.0

~ 600.0

- 200.0

~+ 400.0

0 ~ 1600 ℃

0 ~ 1600 ℃

0 ~ 1800 ℃

0 ~ 1300 ℃

0 ~ 1300 ℃

0 ~ 1400 ℃

PV

量程表

64

67

68

52

53

54

63

C01 编号 传感器类型

41 Pt100

42

43

JPt100

Pt100

44

45

46

51

JPt100

Pt100

JPt100

Pt100

JPt100

Pt100

JPt100

Pt100

JPt100

Pt100

JPt100

0 ~ 2300 ℃

- 200.0

~+ 400.0

- 100.0

~+ 800.0

C01 编号 输入类型

84 0 ~ 1V

86

87

1

0

5V

5V

88

89

90

0

4

0 ~

10V

20mA

20mA

量程

- 200 ~+ 500 ℃

- 200 ~+ 500 ℃

- 200 ~+ 200 ℃

- 200 ~+ 200 ℃

- 100 ~+ 300 ℃

- 100 ~+ 300 ℃

- 50.0

~+ 200.0

- 50.0

~+ 200.0

- 50.0

~+ 100.0

- 50.0

~+ 100.0

0.0

~ 200.0

0.0

~ 200.0

0 ~ 500 ℃

0 ~ 500 ℃

量程

- 1999 ~+ 9999 的量

程 范 围 , 小 数 点 位 置

可变

使用上的注意事项

• B 型热电偶的精度为 260 ℃以下 ± 5%FS 、 260 ~ 800 ℃ ± 1%FS 。

• 在 0 ~ 32 ℉的量程范围内, PL II 热电偶 (C01 No.19) 的指示精度不

能满足本规格书的规定。

• 带小数点显示的量程,显示小数点以下 1 位。

• 根据使用传感器的类型与量程,设定设置数据 C01 的编号。请用

设置数据 C01 设定正确的传感器的类型及量程的编号,否则会引

起大的温度误差而导致异常输出。

报警代码一览表

报警代码

AL01

AL02

AL03

AL11

AL70

AL95

AL96

AL97

AL98

AL99

异常名称 原 因

(

PV 输入异常

超量程 )

PV 输入异常

( 欠量程 )

CJ 异常

传感器断线、误配线

PV 量程种类误设定

传感器断线、误配线

类误设定

PV 量程种

端子温度补偿部故障

( 热电偶 )

PV 输入异常 传感器断线、误配线

( 热电阻 )

CT 输入异常 ( 超量程 )

(CT 输入 1/2 的单方、

或两方 )

超过显示范围上限的电流测量、

CT 匝数误设定、 CT 电力线貫通

次数的误设定

误配线

A/D 转换异常 A/D 转换部故障

确认配线

再次设定

处 理

PV 量程种类

确认环境温度

确认配线

使用匝数与显示范围符合的

CT 、匝数的再设定、 CT 电

力线貫通次数的再设定、配

线的确认

更换本体

参数异常

调整数据异常

参数异常

(RAM 区域 )

调整数据异常

(RAM 区域 )

ROM 异常

数据确定中断电

因干扰等数据被破坏

数据确定中断电

因干扰等数据被破坏

因干扰等数据被破坏

因干扰等数据被破坏

ROM( 内存 ) 故障

 再次投入电源

 再次设定数据

(AL95/97 为设定数据,

AL96/98 为调整数据 )

 更换本体

 再次投入电源

 更换本体

C2

清扫 :

部件更换 : 请勿更换部件。

维护

保险丝更换 : 在更换 AC 电源型的电源保险丝时,务必使用指定规格的产

品。

规格 IEC127 、切断速度 滞后型 (T) 、 额定电压 250V 、额定电

流 0.2A

型号构成表

基本型号 安 装 控制输出 PV 输入 电 源 选 项 语 言

C15M

T

R0

V0

C0

T

R

L

A

01

02

03

规 格

盘安装型

控制输出 1(ot1) 控制输出 2(ot2)

继电器输出 (NO) 继电器输出 (NC)

无 电压脉冲输出

(SSR 驱动用 )

电流输出 无

热电偶输入

(K, J, E, T, R, S, B, N, PLII, WRe5-

26, DINU, DINL)

热电阻输入 (Pt100/JPt 100)

直流电压/电流输入

(0 ~ 1Vdc, 1 ~ 5Vdc, 0 ~ 5Vdc,

0 ~ 10Vdc, 0 ~ 20mAdc, 4 ~ 20mAdc

AC 电源 (100 ~ 240Vac)

事件输出 3 点

事件继电器输出 3 点

电流互感器输入 2 点

数字输入 2 点

事件继电器输出 3 点

电流互感器输入 2 点

RS-485 通讯

00 中文(简体字)

01 中文(繁体字)

规 格

● PV 输入

热电偶 : K 、 J 、 E 、 T 、 R 、 S 、 B 、 N(JIS C 1602-1995)

PL II(Engelhard Industries 資料 (ITS90))

WRe5-26(ASTM E988-96(Reapproved 2002))

DIN U 、 DIN L(DIN 43710-1985)

热电阻 : Pt100(JIS C 1604-1997)

JPt100(JIS C 1604-1989)

直流电压 : 0 ~ 1V 、 1 ~ 5V 、 0 ~ 5V 、 0 ~ 10V

直流电流 : 0 ~ 20mA 、 4 ~ 20mA

采样周期 : 500ms

显示精度 : 0.5

% FS ± 1digit

热电偶的负区域是 ± 1 % FS ± 1digit

( 环境温度 23 ± 3 ℃ )

容许输入 : -0.5V

~ +12V (热电偶、热电阻、直流电压)

30mA 以下或 4V 以下(直流电流)

如果输入容许输入值以上的电压或电流,有可

能损坏仪表

● 数字输入

输入形式 : 无电压接点或开路集电极

容许 ON 接点电阻 : 250 Ω以下

容许 OFF 接点电阻 : 100k Ω以上

容许 ON 残留电压 : 1.0V

以下

ON 时端子电流 : 约 7.5mA ( 短路时 ) 约 5.0mA ( 接点电阻 250 Ω时 )

最小保持时间 : 1s 以上

● 电流互感器输入

点数

输入对象

: 2 点

: 100 ~ 4000 匝 ( 按 100 匝单位对应 )

另售品型号 : QN206A(800 匝、孔径 5.8mm)

另售品型号 : QN212A(800 匝、孔径 12mm)

测量电流下限 : 0.4Aac(800 匝,在电力线貫通次数为 1 时 )

计算式 : 匝数 ÷ (2000 × 电力线貫通次数 )

测量电流上限 : 50.0Aac(800 匝、在电力线貫通次数为 1 时 )

计算式 : 匝数 ÷ (16 × 电力线貫通次数 )

容许测量电流 : 70.0Aac

以下 (800 匝、在电力线貫通次数为 1 时 )

计算式 : 匝数 ÷ (16 × 电力线貫通次数 ) × 1.4

显示范围下限 : 0.0Aac

显示范围上限 : 70.0Aac(800 匝、在电力线貫通次数为 1 时 )

计算式 : 匝数 ÷ (16 × 电力线貫通次数 ) × 1.4

显示精度 : ± 5%FS

显示分辨率 : 0.1Aac

安装件 (C15MT 用 )

密封垫 (C15MT 用 )

电流互感器

硬盖

软盖

端子盖

● 控制输出

• 继电器输出

接点额定值 : NO 侧 250Vac/30Vdc 、

3A( 电阻负荷 )

控制输出 NC 侧 250Vac/30Vdc 、

寿命

1A( 电阻负荷 )

: NO 侧 5 万次以上、

最小开闭规格 : 5V 、 100mA

NC 侧 10 万次以上

最小开时间 / 闭时间 : 250ms

• 电压脉冲输出 (SSR 驱动用 )

开路时电压 : 19Vdc ± 15 %

内部电阻 : 82 Ω ± 0.5

容许电流 : 24mAdc 以下 ( 输出超过该值时,有可能损坏输

出回路。 )

最小 OFF 时间 /ON 时间

: 时间比例周期小于 10s 时 1ms

: 时间比例周期大于 10s 时 250ms

• 电流输出

输出形式 : 0 ~ 20mAdc 或 4 ~ 20mA 电流输出

容许负载电阻 : 600 Ω 以下

输出精度 ± 0.5

% FS ( 环境温度 23

但 0 ~ 1mA 时为 ± 1 % FS

± 3 ℃时 )

● 事件继电器输出 (ev1 ~3 )

接点额定值 : 250Vac /30Vdc 2A ( 电阻负载 )

寿命 : 10 万次 以上

最小开闭规格 : 5V 、 10mA( 参考值 )

● RS-485 通讯

传送路 : 3 线式

传送速度 : 4800 、 9600 、 19200 、 38400bps

通讯协议 : 基于 CPL 、 MODBUS 标准

终端电阻 : 禁止连接

● 环境条件

• 动作条件

环境温度 : 0 ~ 50 ℃ ( 密集安装的場合为 0 ~ 40 ℃ )

环境湿度 : 10 ~ 90 % RH ( 无结露 )

电源电压 : AC 电源型 85 ~ 264Vac 、 50/60Hz ± 2Hz

( 额定值: 100 ~ 240Vac 50/60Hz)

• 运输条件

环境温度 : - 20 ~+ 70 ℃

环境湿度 : 10 ~ 95 % RH ( 无结露 )

● 其他规格

保护等級 : IP66/NEMA 4 基准

( 使用付属的垫片时,仅限于盘单个安装 )

消耗功率 : AC 电源型

12VA 以下 (100Vac 时 8VA 、 264Vac 时 12VA)

( 与本公司 SDC10 相当功能的场合, 100Vac 时

6VA 、 264Vac 时 9VA)

断电停歇时间 : AC 电源型 20ms 以下

高 度

质 量

: 2000m

: 盘安装型 约

端子螺丝拧紧扭矩 : 0.4

~ 0.6N·m

150 g ( 含专用安装件 )

适合规格 : EN61010-1 、

EN61326-1(For use in industrial locations)

在 EMC 试验中,有产生相当于 ± 10%FS 的指

示值或输出值变动的情况。

过电压类别 : Category II (IEC60364-4-443 、 IEC60664-1)

容许汚染度 : Pollution degree2

使用电缆 : 热 电偶输入

请直接把热电偶引线连接到端子上。

配线距离长的场合或热电偶是端子连接的场

合,请用补偿导线延长后与端子连接。

其 它的输入输出

请使用与 JCS-4364 弱电仪表用电缆相当的产

品。电磁干扰比较小的场合,可使用带屏蔽

的多芯微音器电缆 (MVVS) 。

附属品

名 称

选项部件一览表

型 号

81409651-001 ( 附属品 )

81409657-001 ( 附属品 )

QN206A ( 孔径 5.8mm)

QN212A ( 孔径 12mm)

81446442-001

81446443-001

81446898-001

各部件的名称和功能

SDC15

SDC15 pv

④ sp mode rdy man ev1 para ev2 ev3 ot1 ot2

⑤ ⑥

① 第 1 显示部:

② 第 2 显示部:

显示 PV 值 ( 现在的温度等 ) 或设定项目。

显示 SP 值 ( 设定温度值等 ) 或各设定项目的设定

值。

③ 模式显示灯 rdy : READY 模式 ( 控制停止 ) 时灯亮 man : MANUAL 模式 ( 手动 ) 时灯亮 ev1 ~ ev3 : 事件继电器输出 ON 时灯亮

④ [mode] 键: ot1 ~ ot2 : 控制输出为 ON 时灯亮

连续按键 1s 以上时可进行预先设定的操作。

出厂时设定为 RUN/READY 切换。

显示切换。 ⑤ [para] 键:

⑥ <、∨、∧键: 数值增减、位变更时使用。

⑦ 编程器插口: 使用智能编程器软件包同包装的专用电缆与计

算机连接。

键操作和设定

下图表示键操作的流程。各种显示或设定可以从面板上调出。

电源投入时显示 pv sp mode rdy man ev1 ev2 ev3 ot1 ot2 para

灯灭

灯灭

模式显示灯从左依

次灯亮

电源投入后 6s 内,第 1 显示部、第 2 显示部保持灯灭状态,

模式显示灯从左依次灯亮。如果所有的灯亮,则切换到运行

显示。

运行显示 pv sp mode

PV/SP 显示

按 para 键 pv sp mode

MV 显示

按 para 键

(

其它显示、设定

重复 para 键操作 )

按 para 键

2s 以上 pv sp mode

3min 以上不进行键操作

按 mode 键 按 para 键

2s 以上

参数设定显示

AUTO/MANUAL

按 para 键

切换

3min 以上不进行键操作

mode

按 para 键 2s 以上

设置数据设定显示 pv sp mode

PV 量程种类设定

按 para 键 pv sp mode

RUN/READY 切换

按 para 键

其它设定

( 重复 para 键操作 ) pv sp mode

温 度 单 位 设 定

按 para 键

其它设定

( 重复 para 键操作 )

按 para 键 按 para 键 按 para 键

此图中描写的显示或设定状态是说明用的例子。

实际中根据型号或设定内容,显示或设定可能不显示。

● PV 输入量程的设定

设定显示「 C01 」下按 [ < ] 、 [ ∨ ] 、 [ ∧ ] 键,在第 2 显示部上设定希望

的 PV 量程种类。

不需按键 , 只要经过 2s 以上时 , 闪烁将停止, PV 量程种类的设定完

成。

● SP 的设定

运行显示的 PV/SP 显示中按 [ < ] 、 [ ∨ ] 、 [ ∧ ] 键 , 变更第 2 显示部的

SP 。

不需按键 , 只要经过 2s 以上时 , 数值闪烁将停止,确定设定值。

SP 在参数设定显示下也可以设定。

C01 编号 传感器类型

1 K

2 K

3

4

K

K

5

6

K

K

9

10

11

13

14

15

16

J

J

J

E

T

R

S

B 17

18

19

20

N

PL II

WRe5-26

21

24

25

WRe5-26

DIN U

DIN L

量程

- 200 ~+ 1200 ℃

0 ~ 1200 ℃

0.0

~ 800.0

0.0

~ 600.0

0.0

~ 400.0

- 200.0

~+ 400.0

0.0

~ 800.0

0.0

~ 600.0

- 200.0

~+ 400.0

0.0

~ 600.0

- 200.0

~+ 400.0

0 ~ 1600 ℃

0 ~ 1600 ℃

0 ~ 1800 ℃

0 ~ 1300 ℃

0 ~ 1300 ℃

0 ~ 1400 ℃

PV

量程表

64

67

68

52

53

54

63

C01 编号 传感器类型

41 Pt100

42

43

JPt100

Pt100

44

45

46

51

JPt100

Pt100

JPt100

Pt100

JPt100

Pt100

JPt100

Pt100

JPt100

Pt100

JPt100

0 ~ 2300 ℃

- 200.0

~+ 400.0

- 100.0

~+ 800.0

C01 编号 输入类型

84 0 ~ 1V

86

87

1

0

5V

5V

88

89

90

0

4

0 ~

10V

20mA

20mA

量程

- 200 ~+ 500 ℃

- 200 ~+ 500 ℃

- 200 ~+ 200 ℃

- 200 ~+ 200 ℃

- 100 ~+ 300 ℃

- 100 ~+ 300 ℃

- 50.0

~+ 200.0

- 50.0

~+ 200.0

- 50.0

~+ 100.0

- 50.0

~+ 100.0

0.0

~ 200.0

0.0

~ 200.0

0 ~ 500 ℃

0 ~ 500 ℃

量程

- 1999 ~+ 9999 的量

程 范 围 , 小 数 点 位 置

可变

使用上的注意事项

• B 型热电偶的精度为 260 ℃以下 ± 5%FS 、 260 ~ 800 ℃ ± 1%FS 。

• 在 0 ~ 32 ℉的量程范围内, PL II 热电偶 (C01 No.19) 的指示精度不

能满足本规格书的规定。

• 带小数点显示的量程,显示小数点以下 1 位。

• 根据使用传感器的类型与量程,设定设置数据 C01 的编号。请用

设置数据 C01 设定正确的传感器的类型及量程的编号,否则会引

起大的温度误差而导致异常输出。

报警代码一览表

报警代码

AL01

AL02

AL03

AL11

AL70

AL95

AL96

AL97

AL98

AL99

异常名称 原 因

PV 输入异常

( 超量程 )

PV 输入异常

( 欠量程 )

CJ 异常

传感器断线、误配线

PV 量程种类误设定

传感器断线、误配线

类误设定

PV 量程种

PV 输入异常

CT 输入异常 ( 超量程 )

(CT 输入 1/2 的单方、

或两方 )

A/D 转换异常

端子温度补偿部故障

( 热电偶 )

传感器断线、误配线

( 热电阻 )

超过显示范围上限的电流测量、

CT 匝数误设定、 CT 电力线貫通

次数的误设定

误配线

A/D 转换部故障

处 理

确认配线

再次设定 PV 量程种类

确认环境温度

确认配线

使用匝数与显示范围符合的

CT 、匝数的再设定、 CT 电

力线貫通次数的再设定、配

线的确认

更换本体

参数异常

调整数据异常

参数异常

(RAM 区域 )

调整数据异常

(RAM 区域 )

ROM 异常

数据确定中断电

因干扰等数据被破坏

数据确定中断电

因干扰等数据被破坏

因干扰等数据被破坏

因干扰等数据被破坏

ROM( 内存 ) 故障

 再次投入电源

 再次设定数据

(AL95/97 为设定数据,

AL96/98 为调整数据 )

 更换本体

 再次投入电源

 更换本体

C2

维护

清扫 :

部件更换 : 请勿更换部件。

保险丝更换 在更换

品。

AC 电源型的电源保险丝时,务必使用指定规格的产

规格 IEC127 、切断速度 滞后型 (T) 、 额定电压 250V 、额定电

流 0.2A

型号构成表

基本型号 安 装 控制输出 PV 输入 电 源 选 项 语 言

C15M

T

R0

V0

C0

T

R

L

A

01

02

03

规 格

盘安装型

控制输出 1(ot1) 控制输出 2(ot2)

继电器输出 (NO) 继电器输出 (NC)

无 电压脉冲输出

(SSR 驱动用 )

电流输出 无

热电偶输入

(K, J, E, T, R, S, B, N, PLII, WRe5-

26, DINU, DINL)

热电阻输入 (Pt100/JPt 100)

直流电压/电流输入

(0 ~ 1Vdc, 1 ~ 5Vdc, 0 ~ 5Vdc,

0 ~ 10Vdc, 0 ~ 20mAdc, 4 ~ 20mAdc

AC 电源 (100 ~ 240Vac)

事件输出 3 点

事件继电器输出 3 点

电流互感器输入 2 点

数字输入 2 点

事件继电器输出 3 点

电流互感器输入 2 点

RS-485 通讯

00 中文(简体字)

01 中文(繁体字)

规 格

● PV 输入

热电偶 : K 、 J 、 E 、 T 、 R 、 S 、 B 、 N(JIS C 1602-1995)

PL II(Engelhard Industries 資料 (ITS90))

WRe5-26(ASTM E988-96(Reapproved 2002))

DIN U 、 DIN L(DIN 43710-1985)

热电阻 : Pt100(JIS C 1604-1997)

JPt100(JIS C 1604-1989)

直流电压 : 0 ~ 1V 、 1 ~ 5V 、 0 ~ 5V 、 0 ~ 10V

直流电流 : 0 ~ 20mA 、 4 ~ 20mA

采样周期 : 500ms

显示精度 : 0.5

% FS ± 1digit

热电偶的负区域是 ± 1 % FS ± 1digit

( 环境温度 23 ± 3 ℃ )

容许输入 : -0.5V

~ +12V (热电偶、热电阻、直流电压)

30mA 以下或 4V 以下(直流电流)

如果输入容许输入值以上的电压或电流,有可

能损坏仪表

● 数字输入

输入形式 : 无电压接点或开路集电极

容许 ON 接点电阻 : 250 Ω以下

容许 OFF 接点电阻 : 100k Ω以上

容许 ON 残留电压 : 1.0V

以下

ON 时端子电流 : 约 7.5mA ( 短路时 ) 约 5.0mA ( 接点电阻 250 Ω时 )

最小保持时间 : 1s 以上

● 电流互感器输入

点数

输入对象

: 2 点

: 100 ~ 4000 匝 ( 按 100 匝单位对应 )

另售品型号 : QN206A(800 匝、孔径 5.8mm)

另售品型号 : QN212A(800 匝、孔径 12mm)

测量电流下限 : 0.4Aac(800 匝,在电力线貫通次数为 1 时 )

计算式 : 匝数 ÷ (2000 × 电力线貫通次数 )

测量电流上限 : 50.0Aac(800 匝、在电力线貫通次数为 1 时 )

计算式 : 匝数 ÷ (16 × 电力线貫通次数 )

容许测量电流 : 70.0Aac

以下 (800 匝、在电力线貫通次数为 1 时 )

计算式 : 匝数 ÷ (16 × 电力线貫通次数 ) × 1.4

显示范围下限 : 0.0Aac

显示范围上限 : 70.0Aac(800 匝、在电力线貫通次数为 1 时 )

计算式 : 匝数 ÷ (16 × 电力线貫通次数 ) × 1.4

显示精度 : ± 5%FS

显示分辨率 : 0.1Aac

安装件 (C15MT 用 )

密封垫 (C15MT 用 )

电流互感器

C4

硬盖

软盖

端子盖

● 控制输出

• 继电器输出

接点额定值 : NO 侧 250Vac/30Vdc 、

3A( 电阻负荷 )

控制输出 NC 侧 250Vac/30Vdc 、

寿命

1A( 电阻负荷 )

: NO 侧 5 万次以上、

最小开闭规格 : 5V 、 100mA

NC 侧 10 万次以上

最小开时间 / 闭时间 : 250ms

• 电压脉冲输出 (SSR 驱动用 )

开路时电压 : 19Vdc ± 15 %

内部电阻 : 82 Ω ± 0.5

容许电流 : 24mAdc 以下 ( 输出超过该值时,有可能损坏输

出回路。 )

最小 OFF 时间 /ON 时间

: 时间比例周期小于 10s 时 1ms

: 时间比例周期大于 10s 时 250ms

• 电流输出

输出形式 : 0 ~ 20mAdc 或 4 ~ 20mA 电流输出

容许负载电阻 : 600 Ω 以下

输出精度 ± 0.5

% FS ( 环境温度 23

但 0 ~ 1mA 时为 ± 1 % FS

± 3 ℃时 )

● 事件继电器输出 (ev1 ~3 )

接点额定值 : 250Vac /30Vdc 2A ( 电阻负载 )

寿命 : 10 万次 以上

最小开闭规格 : 5V 、 10mA( 参考值 )

● RS-485 通讯

传送路 : 3 线式

传送速度 : 4800 、 9600 、 19200 、 38400bps

通讯协议 : 基于 CPL 、 MODBUS 标准

终端电阻 : 禁止连接

● 环境条件

• 动作条件

环境温度 : 0 ~ 50 ℃ ( 密集安装的場合为 0 ~ 40 ℃ )

环境湿度 : 10 ~ 90 % RH ( 无结露 )

电源电压 : AC 电源型 85 ~ 264Vac 、 50/60Hz ± 2Hz

( 额定值: 100 ~ 240Vac 50/60Hz)

• 运输条件

环境温度 : - 20 ~+ 70 ℃

环境湿度 : 10 ~ 95 % RH ( 无结露 )

● 其他规格

保护等級 : IP66/NEMA 4 基准

( 使用付属的垫片时,仅限于盘单个安装 )

消耗功率 : AC 电源型

12VA 以下 (100Vac 时 8VA 、 264Vac 时 12VA)

( 与本公司 SDC10 相当功能的场合, 100Vac 时

6VA 、 264Vac 时 9VA)

断电停歇时间 : AC 电源型 20ms 以下

高 度

质 量

: 2000m

: 盘安装型 约 150

端子螺丝拧紧扭矩 : 0.4

~ 0.6N·m g ( 含专用安装件 )

适合规格 : EN61010-1 、

EN61326-1(For use in industrial locations)

在 EMC 试验中,有产生相当于 ± 10%FS 的指

示值或输出值变动的情况。

过电压类别 : Category II (IEC60364-4-443 、 IEC60664-1)

容许汚染度 : Pollution degree2

使用电缆 : 热 电偶输入

请直接把热电偶引线连接到端子上。

配线距离长的场合或热电偶是端子连接的场

合,请用补偿导线延长后与端子连接。

其 它的输入输出

请使用与 JCS-4364 弱电仪表用电缆相当的产

品。电磁干扰比较小的场合,可使用带屏蔽

的多芯微音器电缆 (MVVS) 。

附属品

名 称

选项部件一览表

型 号

81409651-001 ( 附属品 )

81409657-001 ( 附属品 )

QN206A ( 孔径 5.8mm)

QN212A ( 孔径 12mm)

81446442-001

81446443-001

81446898-001

C4

C15M

参数一览表

[ 运行显示一览表 ]

■ 运行显示

显 示

第 1 显示: PV

第 2 显示: SP

LSP1

第 2 显示: LSP out

HEAt

CooL

第 1 显示: PV

At1

( 显示例 )

Ct1

Ct2

E1

E1.Sb t1

E2

E2.Sb t2

E3

E3.Sb t3

项 目 内 容

SP ( 目标值 )

LSP 组编号

( 第 1 位=最右位的数值 )

MV( 操作量 )

SP 限幅下限 (C07) ~

SP 限幅上限 (C08)

1 ~ LSP 使用组数 (C30 、最大 4)

- 10.0

~+ 110.0

AUTO 模式下设定不可

( 无数值闪烁 )

MANUAL 模式下设定可能

( 数值闪烁 )

设定不可

- 10.0

~+ 110.0

加热 MV( 操作量 )

冷却 MV( 操作量 )

AT 进程

( 第 1 位=最右位的数值 )

CT( 电流互感器 ) 输入 1

电流值

CT( 电流互感器 ) 输入 2

电流值

内部事件 1 主设定

内部事件 1 副设定

定时器剩余时间

内部事件

内部事件

定时器剩余时间

内部事件

内部事件

2

2

3

3

主设定

副设定

主设定

副设定

定时器剩余时间

1

2

3

设定不可

1 ~: AT

设定不可

设定不可

启动中 ( 值减小 )

根据内部事件动作种类,可设定的范

围不同

- 1999 ~+ 9999U :下述以外的场合

0 ~ 9999U :设定值是绝对值的场合

- 199.9

~+ 999.9

%: MV 的场合

设定不可

第 1 显示 : 「 t1 .」的旁边显示 ON 延迟、

OFF 延迟的区别

第 2 显示:内部事件 1 延迟时间

按照单位 (E1.C3

的第 3 位 ) 的单位

(0.1s

、 s 、 min 中的一个 ) 显示

根据内部事件动作种类,可设定的范

围不同

- 1999 ~+ 9999U :下述以外的场合

0 ~ 9999U :设定是绝对值的场合

- 199.9

~+ 999.9

%: MV 的场合

设定不可

第 1 显示 : 「 t2 .」的旁边显示 ON 延迟、

OFF 延迟的区别

第 2 显示:内部事件 1 延迟时间

按照单位 (E2.C3

的第 3 位 ) 的单位

(0.1s

、 s 、 min 中的一个 ) 显示

根据内部事件动作种类,可设定的范

围不同

- 1999 ~+ 9999U :下述以外的场合

0 ~ 9999U :设定是绝对值的场合

- 199.9

~+ 999.9

%: MV 的场合

设定不可

第 1 显示 : 「 t3 .」的旁边显示 ON 延迟、

OFF 延迟的区别

第 2 显示:内部事件 1 延迟时间

按照单位 (E3.C3

的第 3 位 ) 的单位

(0.1s

、 s 、 min 中的一个 ) 显示

初始值 显示

级别

0 0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

[ 参数设定显示一览表 ]

■ 模式库

库选择 : M ODE

显 示 项 目

A--M r--r

At

AUTO/MANUAL 模式

切换

RUN/READY 模式切换

AT 停止 / 启动切换 do.Lt

C.dI1

全 DO 锁定解除

通讯 DI1

内 容

AUTo : AUTO( 自动 ) 模式 n-an : MANUAL( 手动 ) 模式

RUN : RUN 模式

RDY : READY 模式

At.oF

: AT 停止

At.oN

: AT 启动

Lt.oN

:锁定继续

Lt.oF

:锁定解除 dI.oF

: OFF dI.on

: ON

初始值 显示 级

AUTO 0

RUN

AT 停止

0

0

锁定

继续

OFF

0

0

■ SP 库

库选择: SP

显 示

SP-1 ~

SP-4

项 目

LSP1 ~ 4 组的 SP

内 容

SP 限幅下限 (C07) ~

SP 限幅上限 (C08)

初始值 显示

级别

0 0

■ 事件库

库选择 : EU

显 示 项 目

内部事件 1 ~ 5 主设定

内部事件 1 ~ 5 副设定

E1 ~ E5

E1.Sb

E5.Sb

E1.H

E5.Hy

E1.on

E5.on

E1.oF

E5.oF

内部事件 1 ~ 5 回差

内部事件 1 ~ 5 ON 延迟

内部事件 1 ~ 5 OFF 延迟

内 容

- 1999 ~+ 9999

小数点位置根据内部事件动作种类变

化 一部分的动作种类为 0 ~ 9999

初始值 显示

级别

0

0

0

0

0 ~ 9999

小数点位置根据内部事件动作种类变化

0.0

~ 999.9

( 延迟时间单位 0.1s

的场合 )

0 ~ 9999

( 延迟时间单位 0.1s

以外的场合 )

5

0

0

0

2

2

C5

显示级别的含义 0 :简单、标准、多功能显示 ,

1 :标准、多功能显示

2 :多功能显示

初始值有根据型号变化的情况。

■ PID 库

库选择 : PID

显 示

P-1

I-1

比例带

積分时间

项 目 d-1 rE-1 oL-1 oH-1

P-1C

I-1C d-1C oL.1C oH.1C

微分时间

手动复位

操作量下限

操作量上限

冷却侧比例帯

冷却侧积分时间

冷却侧微分时间

冷却侧操作量下限

冷却侧操作量上限

内 容

0.1

~ 999.9

0 ~ 9999s

(0 时无积分动作 )

0 ~ 9999s

(0 时无微分动作 )

- 10.0

~+ 110.0

- 10.0

~+ 110.0

- 10.0

~+ 110.0

0.1

~ 999.9

0 ~ 9999s

(0 时无积分动作 )

0 ~ 9999s

(0 时无微分动作 )

- 10.0

~+ 110.0

- 10.0

~+ 110.0

初始值

5.0

120

30

50.0

0.0

100.0

5.0

120

30

0.0

100.0

0

1

0

0

0

1

显示

级别

0

0

0

1

1

■ 参数库

库选择 : PARA

显 示 项 目

CtrL

At.oL

At.oH dIFF oFFS

FL rA bI

CyU

Cy

CyU2

Cy2 tP.ty

SPU

SPd

内 容 初始值

控制方式 0 : ON/OFF 控制

1 : PID 固定

2 : ST( 自适应 )

- 10.0

~+ 110.0

% AT 时操作量下限

AT 时操作量上限

ON/OFF 控制差动

- 10.0

~+ 110.0

0 ~ 9999U

ON/OFF 控制动作点偏移量 - 1999 ~+ 9999U

PV 滤波 0.0

~ 120.0s

PV 比率

PV 偏置

时间比例单位 1

时间比例周期

时间比例单位

时间比例周期

时间比例动作种类

SP

1

2

2

斜坡上升斜率

SP 斜坡下降斜率

0.001

~ 9.999

- 1999 ~+ 9999U

0 : 1s 单位

1 : 0.5s

固定 ( 周期设定不可 )

2 : 0.2s

固定 ( 周期设定不可 )

3 : 0.1s

固定 ( 周期设定不可 )

5 ~ 120s ( 输出中包含继电器输出的

场合 )

1 ~ 120s ( 输出中不包含继电器输出

的场合 )

0 : 1s 单位

1 : 0.5s

固定 ( 周期设定不可 )

2 : 0.2s

固定 ( 周期设定不可 )

3 : 0.1s

固定 ( 周期设定不可 )

5 ~ 120s ( 输出中包含继电器输出的

场合 )

1 ~ 120s ( 输出中不包含继电器输出

的场合 )

0 :控制性重视型

1 : 操作端寿命重视型 ( 时间比例周

期内 仅 1 回 ON/OFF 动作 )

0.0

~ 999.9U (0.0U

时无斜率 )

0 、

1

0.0

100.0

5

0

0.0

1.000

0

0

10

10

0

0

2

2

1

0.0

0.0

显示

级别

0

0

2

0

2

2

2

0

2

0

0

0

1

0

2

■ 扩展调整库

库选择 : ET

显 示

At.ty

JF.bd

SP.LG

At-P

At-I

At-d

Ctr.A

JF.ov

St.SA

St.Sb

St.Hb

St.ud

AT 种类

项 目

JF 整定幅

SP 抑制时常数

AT 时比例带调整系数

AT 时积分时间调整系数

AT 时微分时间调整系数

控制运算

JF 超调抑制系数

ST 阶跃执行判定幅

ST 阶跃整定幅

ST 振荡整定幅

ST 阶跃升降切换

内 容

0 :通常 ( 标准的控制特性 )

1 : 立即响应 ( 对干扰迅速反应的控制

特性 )

2 :稳定 (PV 上下波动少的控制特性 )

0.00

~ 10.00

0.0

~ 999.9

0.00

~ 99.99

0.00

~ 99.99

0.00

~ 99.99

0 : PID ( 传统型 PID)

1 : Ra-PID ( 高性能型 PID)

0 ~ 100

0.00

~ 99.99

0.00

~ 10.00

0.00

~ 10.00

0 : PV 上升 / 下降时均执行 ST

1 :仅 PV 上升时执行 ST

初始值 显示 级

1 0

0.30

0.0

1.00

1.00

1.00

0

0

10.00

0.50

1.00

0

2

2

1

1

2

2

2

1

2

2

2

C3

C38

C39

C40

C41

C42

C47

C48

C49

C50

C51

[ 运行显示一览表 ]

■ 设置库

库选择 : STUP

显 示 项 目

C01

C02

C03

C04

C05

C06

C07

C08

C09

C14

C15

C16

C17

C18

C19

C20

C21

C22

C26

C27

C28

C29

C30

C32

C36

C37

C43

C44

C45

C46

内 容 初始值

PV 量程种类

温度单位

冷端补偿

小数点位置

PV

PV

量程下限

量程上限

热电偶 (T) 的场合:

1 ~ 6 、 9 ~ 11 、 13 ~ 21 、 24 、 25

热电阻 (R) 的场合:

41 ~ 46 、 51 ~ 54 、 63 、 64 、 67 、 68

直流电压 / 直流电流 (L) 的场合:

84 、 86 ~ 90

0 :摄氏 ( ℃ )

1 :华氏 ( ℉ )

0 :进行冷端补偿 ( 内部 )

1 :不进行冷端补偿 ( 外部 )

0 :无小数点

1 :小数点以下 1 位

2 :小数点以下 2 位

3 : 小数点以下 3 位

( 热电阻带小数点量程的场合 0 ~ 1)

PV 输入型号为热电偶 (T) 、热电阻 (R) 的

场合,显示量程的下限,但设定不可

PV 输入型号为直流电压 / 直流电流 (L)

的场合,- 1999 ~+ 9999U

PV 输入型号为热电偶 (T) 、热电阻 (R) 的

场合,显示量程的上限,但设定不可

SP 限幅下限

SP 限幅上限

PV 输入型号为直流电压 / 直流电流 (L)

的场合,- 1999 ~+ 9999U

PV 量程下限~ PV 量程上限

开方运算小数舍去

控制动作

PV

( 正逆 )

异常时操作量选择

PV 异常时操作量

0.0

~ 100.0

(0.0

时无开方运算 )

0 :加热控制 ( 逆动作 )

1 :冷却控制 ( 正动作 )

0 :继续控制运算

1 : PV 异常时输出操作量

- 10.0

~+ 110.0

READY 时操作量 ( 加热冷

却 控制的场合为加热侧 )

READY 时 操 作 量 ( 冷 却

侧 )

MANUAL 变更时动作

10.0

10.0

~+

~+

110.0

110.0

预置 MANUAL 值

0 :无扰

1 :预置

- 10.0

~+ 110.0

( 电源 ON 时、处于 MANUAL 模式时也

使用 )

PID 运算初始化功能选择 0 :自动

1 :不初始化

2 :初始化

( 输入和现在值不同的 SP 值时 )

PID 运算初始操作量 - 10.0

~+ 110.0

加热冷却控制选择

加热冷却切换

加热冷却控制不感带

加热冷却控制切换点

LSP 使用组数

SP 斜坡单位

CT1

CT1

CT1

CT2

动作

监视输出

测定等待时间

动作

CT2 监视输出

CT2 测定等待时间

控制输出 1 量程

0 :不使用

1 :使用

0 :通常

1 :节能

- 100.0

~+ 100.0

- 10.0

~+ 110.0

1 ~ 4

0 : 0.1U/s

1 : 0.1U/min

2 : 0.1U/h

0 :加热器断线检测

1 :电流值测定

0 :控制输出 1

1 :控制输出 2

2 :事件输出 1

3 :事件输出 2

4 :事件输出 3

30 ~ 300ms

和 CT1 相同

1

41

88

0

0

0

0

1000

0.0

0

0

0.0

0.0

0.0

0

0.0

50.0

0

0.0

50.0

0

0

0.0

50.0

1

1

0

0

30

0

0

30

1

控制输出

控制输出

控制输出

1

1

1

控制输出 1

MV 量程幅

种类

量程下限

量程上限

控制输出 2 量程

控制输出 2 量程种类

控制输出 2 量程下限

控制输出 2 量程上限

控制输出 2

MV 量程幅

1 : 4 ~ 20mA

2 : 0 ~ 20mA

0 : MV

1 :加热 MV ( 加热冷却控制用 )

2 :冷却 MV ( 加热冷却控制用 )

3 : PV

4 :比率、偏置、滤波前 PV

5 : SP

6 :偏差 (PV-SP)

7 : CT1 电流值

8 : CT2 电流值

9 : MFB (C15M 时无效 )

10 : SP+MV

11 : PV+MV

- 1999 ~+ 9999( 小数点位置根据控

制输出 1 的种类变化 )

0 ~ 9999

小数点位置及单位与 PV 相同

与控制输出 1 相同

0

1999

制输出

2

~+

9999

9999( 小数点位置根据控

的种类变化 )

小数点位置及单位与 PV 相同

0

0.0

100.0

200

13

0

1000

200

显示

级别

0

0

0

2

0

0

0

0

0

0

0

0

0

0

0

00

0

0

0

0

0

2

0

2

0

1

0

2

0

2

1

1

1

0

2

2

1

1

1

2

CP-UM-5410EC

C78

C79

C80

C67

C68

C69

C70

C71

C72

显 示

C64

C65

C66

C73

C74

C75

C76

C77

C90

C91

C92

C93

通讯种类

机器地址

传送速度

数据形式

数据形式

数据形式 ( 停止位

键功能

)

通讯最小应答时间

键操作种类

Mode

模式显示设定

PV/SP 值显示设定

操作量显示设定

事件设定值显示设定

事件剩余时间显示设定

CT 输入电流值显示设定

显示级别

LED

CT1

监视

匝数

(

(

项 目

数据长

校验 )

)

CT1 电力线貫通回数

CT2 匝数

CT2 电力线貫通回数

内 容

0 : CPL

1 : MODBUS ASCII 形式

2 : MODBUS RTU 形式

0 ~ 127

(0 时不通讯 )

0 : 4800bps

1 : 9600bps

2 : 19200bps

3 : 38400bps

0 : 7 位

1 : 8 位

0 :偶数校验

1 :奇数校验

2 :无校验

0 : 1 位

1 : 2 位

1 ~ 250ms

0 :标准型

1 :特殊型

0 :无效

1 : AUTO/MANUAL 切换

2 : RUN/READY 切换

3 : AT 停止 / 启动

4 : LSP 组切换

5 :全 DO 锁定解除

6 :无效

7 :通讯 DI1 切换

8 :无效

模式组的设定显示有无,由下列的加

权的和决定

位 0 : AUTO/MANUAL 显示

无: 0 、有: +1

位 1 : RUN/READY 显示

无: 0 、有: +2

位 3 : AT 停止 / 启动显示

无: 0 、有: +8

位 4 : DO 锁定解除显示

无: 0 、有: +16

位 5 : 通讯 DI1 ON/OFF 显示

无: 0 、有: +32

其他无效的设定 0 、 +4 、 +64 、 +128

基本显示的显示有无,由下列的加权

的 和决定

位 0 : PV 显示

无: 0 、有: +1

位 1 : SP 显示

无: 0 、有: +2

位 2 : LSP 组编号显示

无: 0 、有: +4

其他无效的设定 0 、 +8

基本显示的显示有无,由下列的加权

的和决定

位 0 : MV 显示

无: 0 、有: +1

位 1 : 加热 MV/ 冷却 MV 显示

无: 0 、有: +2

位 3 : AT 进程显示

无: 0 、有: +8

其他无效的设定 0 、 +4

0 : 运行显示时不显示内部事件设定

1 : 运行显示时显示内部事件 1 设定

2 : 运行显示时显示内部事件 1 ~ 2 设

定值

3 : 运行显示时显示内部事件 1 ~ 3 设

定值

0 : 运 行 显 示 时 不 显 示 内 部 事 件 的

ON/OFF 延迟剩余时间

1 : 运行显示时显示内部事件 1 的 ON/

OFF 延迟剩余时间

2 : 运行显示时显示内部事件 1 ~ 2 的

ON/OFF 延迟剩余时间

3 : 运行显 示 时显示内部事 1 ~ 3

0 :运行显示时不显示 CT 的电流值

1 :运行显示时显示 CT1 电流值

2 :运行显示时显示 CT1 ~ 2 电流值

0 :简单设定

1 :标准设定

2 :多功能设定

0 :不使用

1 : RS-485 通讯发送时闪烁

2 : RS-485 通讯接收时闪烁

3 :全 DI 状态的 OR( 逻辑和 )

4 : READY 时闪烁

0: 800 匝

1 ~ 40:CT 的匝数除以 100 后的值

0: 1 回

1 ~ 6: 回数

0: 800 匝

1 ~ 40:CT 的匝数除以 100 后的值

0: 1 回

1 ~ 6: 回数

初始值

0

0

2

1

0

255

15

15

0

0

0

0

0

8

1

8

1

0

3

0

1

显示

级别

0

0

0

0

0

0

2

2

0

1

1

1

1

1

1

0

2

2

2

2

2

( 下页续 )

C15M

参数一览表

[ 运行显示一览表 ]

■ 运行显示

显 示

第 1 显示: PV

第 2 显示: SP

LSP1

第 2 显示: LSP out

HEAt

CooL

第 1 显示: PV

At1

( 显示例 )

Ct1

Ct2

E1

E1.Sb t1

E2

E2.Sb t2

E3

E3.Sb t3

项 目 内 容

SP ( 目标值 )

LSP 组编号

( 第 1 位=最右位的数值 )

MV( 操作量 )

SP 限幅下限 (C07) ~

SP 限幅上限 (C08)

1 ~ LSP 使用组数 (C30 、最大 4)

- 10.0

~+ 110.0

AUTO 模式下设定不可

( 无数值闪烁 )

MANUAL 模式下设定可能

( 数值闪烁 )

设定不可

- 10.0

~+ 110.0

加热 MV( 操作量 )

冷却 MV( 操作量 )

AT 进程

( 第 1 位=最右位的数值 )

CT( 电流互感器 ) 输入 1

电流值

CT( 电流互感器 ) 输入 2

电流值

内部事件 1 主设定

内部事件 1 副设定

定时器剩余时间

内部事件

内部事件

定时器剩余时间

内部事件

内部事件

2

2

3

3

主设定

副设定

主设定

副设定

定时器剩余时间

1

2

3

设定不可

1 ~: AT 启动中

设定不可

设定不可

( 值减小 )

根据内部事件动作种类,可设定的范

围不同

- 1999 ~+ 9999U :下述以外的场合

0 ~ 9999U :设定值是绝对值的场合

- 199.9

~+ 999.9

%: MV 的场合

设定不可

第 1 显示 : 「 t1 .」的旁边显示 ON 延迟、

OFF 延迟的区别

第 2 显示:内部事件 1 延迟时间

按照单位 (E1.C3

的第 3 位 ) 的单位

(0.1s

、 s 、 min 中的一个 ) 显示

根据内部事件动作种类,可设定的范

围不同

- 1999 ~+ 9999U :下述以外的场合

0 ~ 9999U :设定是绝对值的场合

- 199.9

~+ 999.9

%: MV 的场合

设定不可

第 1 显示 : 「 t2 .」的旁边显示 ON 延迟、

OFF 延迟的区别

第 2 显示:内部事件 1 延迟时间

按照单位 (E2.C3

的第 3 位 ) 的单位

(0.1s

、 s 、 min 中的一个 ) 显示

根据内部事件动作种类,可设定的范

围不同

- 1999 ~+ 9999U :下述以外的场合

0 ~ 9999U :设定是绝对值的场合

- 199.9

~+ 999.9

%: MV 的场合

设定不可

第 1 显示 : 「 t3 .」的旁边显示 ON 延迟、

OFF 延迟的区别

第 2 显示:内部事件 1 延迟时间

按照单位 (E3.C3

的第 3 位 ) 的单位

(0.1s

、 s 、 min 中的一个 ) 显示

初始值 显示

级别

0 0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

[ 参数设定显示一览表 ]

■ 模式库

库选择 : M ODE

显 示 项 目

A--M r--r

At do.Lt

C.dI1

AUTO/MANUAL 模式

切换

RUN/READY 模式切换

AT 停止 / 启动切换

全 DO 锁定解除

通讯 DI1

内 容

AUTo : AUTO( 自动 ) 模式 n-an : MANUAL( 手动 ) 模式

RUN : RUN 模式

RDY : READY 模式

At.oF

: AT 停止

At.oN

: AT 启动

Lt.oN

:锁定继续

Lt.oF

:锁定解除 dI.oF

: OFF dI.on

: ON

初始值 显示 级

AUTO 0

RUN 0

AT 停止

锁定

继续

OFF

0

0

0

■ SP 库

库选择: SP

显 示

SP-1 ~

SP-4

项 目

LSP1 ~ 4 组的 SP

内 容

SP 限幅下限 (C07) ~

SP 限幅上限 (C08)

初始值 显示

级别

0 0

■ 事件库

库选择 : EU

显 示 项 目

内部事件 1 ~ 5 主设定

内部事件 1 ~ 5 副设定

E1 ~ E5

E1.Sb

E5.Sb

E1.H

E5.Hy

E1.on

E5.on

E1.oF

E5.oF

内部事件 1 ~ 5 回差

内部事件 1 ~ 5 ON 延迟

内部事件 1 ~ 5 OFF 延迟

内 容

- 1999 ~+ 9999

小数点位置根据内部事件动作种类变

化 一部分的动作种类为 0 ~ 9999

初始值 显示

级别

0

0

0

0

0 ~ 9999

小数点位置根据内部事件动作种类变化

0.0

~ 999.9

( 延迟时间单位 0.1s

的场合 )

0 ~ 9999

( 延迟时间单位 0.1s

以外的场合 )

5

0

0

0

2

2

显示级别的含义 0 :简单、标准、多功能显示 ,

1

2

:标准、多功能显示

:多功能显示

初始值有根据型号变化的情况。

■ PID 库

库选择 : PID

显 示

P-1

I-1

比例带

積分时间

项 目 d-1 rE-1 oL-1 oH-1

P-1C

I-1C d-1C oL.1C oH.1C

微分时间

手动复位

操作量下限

操作量上限

冷却侧比例帯

冷却侧积分时间

冷却侧微分时间

冷却侧操作量下限

冷却侧操作量上限

内 容

0.1

~ 999.9

0 ~ 9999s

(0 时无积分动作 )

0 ~ 9999s

(0 时无微分动作 )

- 10.0

~+ 110.0

- 10.0

~+ 110.0

- 10.0

~+ 110.0

0.1

~ 999.9

0 ~ 9999s

(0 时无积分动作 )

0 ~ 9999s

(0 时无微分动作 )

- 10.0

~+ 110.0

- 10.0

~+ 110.0

■ 参数库

库选择 : PARA

显 示 项 目

CtrL

At.oL

At.oH dIFF oFFS

FL rA bI

CyU

Cy

CyU2

Cy2 tP.ty

SPU

SPd

内 容 初始值

控制方式

AT 时操作量下限

AT 时操作量上限

ON/OFF 控制差动

时间比例周期

时间比例单位

时间比例周期

时间比例动作种类

SP

1

2

2

斜坡上升斜率

SP 斜坡下降斜率

0 : ON/OFF 控制

1 : PID 固定

2 : ST( 自适应 )

- 10.0

~+ 110.0

- 10.0

~+ 110.0

0 ~ 9999U

ON/OFF 控制动作点偏移量 - 1999 ~+ 9999U

PV 滤波 0.0

~ 120.0s

PV 比率

PV 偏置

0.001

1999

9.999

~+ 9999U

时间比例单位 1 0 : 1s 单位

1 : 0.5s

固定 ( 周期设定不可 )

2 : 0.2s

固定 ( 周期设定不可 )

3 : 0.1s

固定 ( 周期设定不可 )

5 ~ 120s ( 输出中包含继电器输出的

场合 )

1 ~ 120s ( 输出中不包含继电器输出

的场合 )

0 : 1s 单位

1 : 0.5s

固定 ( 周期设定不可 )

2 : 0.2s

固定 ( 周期设定不可 )

3 : 0.1s

固定 ( 周期设定不可 )

5 ~ 120s ( 输出中包含继电器输出的

场合 )

1 ~ 120s ( 输出中不包含继电器输出

的场合 )

0 :控制性重视型

1 : 操作端寿命重视型 ( 时间比例周

期内 仅 1 回 ON/OFF 动作 )

0.0

~ 999.9U (0.0U

时无斜率 )

0 、

1

0.0

100.0

5

0

0.0

1.000

0

0

10

10

0

0

2

2

1

0.0

0.0

显示

级别

0

0

2

0

2

2

2

1

0

2

0

0

0

0

2

■ 扩展调整库

库选择 : ET

显 示

At.ty

JF.bd

SP.LG

At-P

At-I

At-d

Ctr.A

JF.ov

St.SA

St.Sb

St.Hb

St.ud

AT 种类

项 目

JF 整定幅

SP 抑制时常数

AT 时比例带调整系数

AT 时积分时间调整系数

AT 时微分时间调整系数

控制运算

JF 超调抑制系数

ST 阶跃执行判定幅

ST 阶跃整定幅

ST 振荡整定幅

ST 阶跃升降切换

内 容

0 :通常 ( 标准的控制特性 )

1 : 立即响应 ( 对干扰迅速反应的控制

特性 )

2 :稳定 (PV 上下波动少的控制特性 )

0.00

~ 10.00

0.0

~ 999.9

0.00

~ 99.99

0.00

~ 99.99

0.00

~ 99.99

0 : PID ( 传统型 PID)

1 : Ra-PID ( 高性能型 PID)

0 ~ 100

0.00

~ 99.99

0.00

~ 10.00

0.00

~ 10.00

0 : PV 上升 / 下降时均执行 ST

1 :仅 PV 上升时执行 ST

初始值 显示 级

1 0

0.30

0.0

1.00

1.00

1.00

0

0

10.00

0.50

1.00

0

2

2

1

2

1

2

2

2

1

2

2

初始值

5.0

120

30

50.0

0.0

100.0

5.0

120

30

0.0

100.0

1

0

0

1

0

0

显示

级别

0

0

0

1

1

C3

C38

C39

C40

C41

C42

C47

C48

C49

C50

C51

[ 运行显示一览表 ]

■ 设置库

库选择 : STUP

显 示 项 目

C01

C02

C03

C04

C05

C06

C07

C08

C09

C14

C15

C16

C17

C18

C19

C20

C21

C22

C26

C27

C28

C29

C30

C32

C36

C37

C43

C44

C45

C46

内 容 初始值

PV

温度单位

冷端补偿

小数点位置

PV

量程种类

量程下限

热电偶 (T) 的场合:

1 ~ 6 、 9 ~ 11 、 13 ~ 21 、 24 、 25

热电阻 (R) 的场合:

41 ~ 46 、 51 ~ 54 、 63 、 64 、 67 、 68

直流电压 / 直流电流 (L) 的场合:

84 、 86 ~ 90

0 :摄氏 ( ℃ )

1 :华氏 ( ℉ )

0 :进行冷端补偿 ( 内部 )

1 :不进行冷端补偿 ( 外部 )

0 :无小数点

1 :小数点以下 1 位

2 :小数点以下 2 位

3 : 小数点以下 3 位

( 热电阻带小数点量程的场合 0 ~ 1)

PV 输入型号为热电偶 (T) 、热电阻 (R) 的

场合,显示量程的下限,但设定不可

PV 量程上限

PV 输入型号为直流电压 / 直流电流 (L)

的场合,- 1999 ~+ 9999U

PV 输入型号为热电偶 (T) 、热电阻 (R) 的

场合,显示量程的上限,但设定不可

PV 输入型号为直流电压 / 直流电流 (L)

的场合,- 1999 ~+ 9999U

PV 量程下限~ PV 量程上限 SP 限幅下限

SP 限幅上限

开方运算小数舍去

控制动作

PV

( 正逆 )

异常时操作量选择

PV 异常时操作量

0.0

~ 100.0

(0.0

时无开方运算 )

0 :加热控制 ( 逆动作 )

1 :冷却控制 ( 正动作 )

0 :继续控制运算

1 : PV 异常时输出操作量

- 10.0

~+ 110.0

READY 时操作量 ( 加热冷

却 控制的场合为加热侧 )

READY 时 操 作 量 ( 冷 却

侧 )

MANUAL 变更时动作

10.0

10.0

~+

~+

110.0

110.0

预置 MANUAL 值

0 :无扰

1 :预置

- 10.0

~+ 110.0

( 电源 ON 时、处于 MANUAL 模式时也

使用 )

PID 运算初始化功能选择 0 :自动

1 :不初始化

2 :初始化

( 输入和现在值不同的 SP 值时 )

PID 运算初始操作量 - 10.0

~+ 110.0

加热冷却控制选择

加热冷却切换

加热冷却控制不感带

加热冷却控制切换点

LSP 使用组数

SP 斜坡单位

CT1

CT1

CT1

CT2

动作

监视输出

测定等待时间

动作

CT2 监视输出

CT2 测定等待时间

控制输出 1 量程

控制输出

控制输出

1

1

种类

量程下限

控制输出 1 量程上限

控制输出 1

MV 量程幅

控制输出 2 量程

控制输出 2 量程种类

控制输出 2 量程下限

控制输出 2 量程上限

控制输出 2

MV 量程幅

0 :不使用

1 :使用

0 :通常

1 :节能

- 100.0

~+ 100.0

- 10.0

~+ 110.0

1 ~ 4

0 : 0.1U/s

1 : 0.1U/min

2 : 0.1U/h

0 :加热器断线检测

1 :电流值测定

0 :控制输出 1

1 :控制输出 2

2 :事件输出 1

3 :事件输出 2

4 :事件输出 3

30 ~ 300ms

和 CT1 相同

1 : 4 ~ 20mA

2 : 0 ~ 20mA

0 : MV

1 :加热 MV ( 加热冷却控制用 )

2 :冷却 MV ( 加热冷却控制用 )

3 : PV

4 :比率、偏置、滤波前 PV

5 : SP

6 :偏差 (PV-SP)

7 : CT1 电流值

8 : CT2 电流值

9 : MFB (C15M 时无效 )

10 : SP+MV

11 : PV+MV

- 1999 ~+ 9999( 小数点位置根据控

制输出 1 的种类变化 )

0 ~ 9999

小数点位置及单位与 PV 相同

与控制输出 1 相同

0

1999

制输出

2

~+

9999

9999( 小数点位置根据控

的种类变化 )

小数点位置及单位与 PV 相同

1

41

88

0

0

0

0

1000

0.0

0

0

0.0

0.0

0.0

0

0.0

50.0

0

0.0

50.0

0

0

0.0

50.0

1

1

0

0

30

0

0

30

1

0

0.0

100.0

200

13

0

1000

200

显示

级别

0

0

0

2

0

0

0

0

0

00

0

0

0

0

0

0

0

0

0

0

0

2

0

2

0

1

0

2

0

2

2

2

1

1

1

1

1

1

2

0

C6

CP-UM-5410EC

C78

C79

C80

C67

C68

C69

C70

C71

C72

显 示

C64

C65

C66

C73

C74

C75

C76

C77

C90

C91

C92

C93

项 目 内 容

通讯种类

机器地址

传送速度

数据形式

数据形式

数据形式 )

)

通讯最小应答时间

键操作种类

Mode 键功能

模式显示设定

PV/SP

(

(

( 数据长

校验 )

停止位

值显示设定

操作量显示设定

事件设定值显示设定

0 : CPL

1 : MODBUS ASCII 形式

2 : MODBUS RTU 形式

0 ~ 127

(0 时不通讯 )

0 : 4800bps

1 : 9600bps

2 : 19200bps

3 : 38400bps

0 : 7 位

1 : 8 位

0 :偶数校验

1 :奇数校验

2 :无校验

0 : 1 位

1 : 2 位

1 ~ 250ms

0 :标准型

1 :特殊型

0 :无效

1 : AUTO/MANUAL 切换

2 : RUN/READY 切换

3 : AT 停止 / 启动

4 : LSP 组切换

5 :全 DO 锁定解除

6 :无效

7 :通讯 DI1 切换

8 :无效

模式组的设定显示有无,由下列的加

权的和决定

位 0 : AUTO/MANUAL 显示

无: 0 、有: +1

位 1 : RUN/READY 显示

位 3 :

无: 0 、有: +2

AT 停止 / 启动显示

无: 0 、有: +8

位 4 : DO 锁定解除显示

无: 0 、有: +16

位 5 : 通讯 DI1 ON/OFF 显示

无: 0 、有: +32

其他无效的设定 0 、 +4 、 +64 、 +128

基本显示的显示有无,由下列的加权

的 和决定

位 0 : PV 显示

无: 0 、有: +1

位 1 : SP 显示

无: 0 、有: +2

位 2 : LSP 组编号显示

无: 0 、有: +4

其他无效的设定 0 、 +8

基本显示的显示有无,由下列的加权

的和决定

位 0 : MV 显示

无: 0 、有: +1

位 1 : 加热 MV/ 冷却 MV 显示

无: 0 、有: +2

位 3 : AT 进程显示

无: 0 、有: +8

其他无效的设定 0 、 +4

0 : 运行显示时不显示内部事件设定

1 : 运行显示时显示内部事件 1 设定

2 : 运行显示时显示内部事件 1 ~ 2 设

定值

3 : 运行显示时显示内部事件 1 ~ 3 设

定值

事件剩余时间显示设定

CT 输入电流值显示设定 0 :运行显示时不显示 CT 的电流值

1 :运行显示时显示 CT1 电流值

2 :运行显示时显示 CT1 ~ 2 电流值

显示级别 0 :简单设定

1 :标准设定

2 :多功能设定

LED 监视

0 : 运 行 显 示 时 不 显 示 内 部 事 件 的

ON/OFF 延迟剩余时间

1 : 运行显示时显示内部事件 1 的 ON/

OFF 延迟剩余时间

2 : 运行显示时显示内部事件 1 ~ 2 的

ON/OFF 延迟剩余时间

3 : 运行显 示 时显示内部事 1 ~ 3

CT1

CT1

匝数

电力线貫通回数

0 :不使用

1 : RS-485 通讯发送时闪烁

2 : RS-485 通讯接收时闪烁

3 :全 DI 状态的 OR( 逻辑和 )

4 : READY 时闪烁

0: 800 匝

1 ~ 40:CT 的匝数除以 100 后的值

0: 1 回

1 ~ 6: 回数

CT2 匝数

CT2 电力线貫通回数

0: 800 匝

1 ~ 40:CT 的匝数除以 100 后的值

0: 1 回

1 ~ 6: 回数

初始值

0

0

2

1

0

255

15

15

0

0

0

0

0

8

1

8

1

0

3

0

1

显示

级别

0

0

0

0

0

1

1

1

1

1

1

0

2

( 下页续 )

0

2

2

0

2

2

2

2

C6

■ 事件组态库

库选择 : EVCF

显 示

E1.C1

E5.C1

E1.C2

E5.C2

E1.C3

E5.C3

项 目

内部事件 1 ~ 5 组态 1

动作种类

内部事件

1

2

1 ~

位:正逆

位:待机

5 组态 2

第 3 位: READY 时动作

第 4 位:未定义

内部事件 1 ~ 5 组态 3

第 1 位:报警 OR

2

3

4

位:特殊 OFF

位:延时时间单位

位:未定义

内 容 初始值

0 :无事件

1 : PV 上限

2 : PV 下限

3 : PV 上下限

4 :偏差上限

5 :偏差下限

6 :偏差上下限

7 :偏差上限 ( 最终 SP 基准 )

8 :偏差下限 ( 最终 SP 基准 )

9 :偏差上下限 ( 最终 SP 基准 )

10 : SP 上限

11 : SP 下限

12 : SP 上下限

13 : MV 上限

14 : MV 下限

15 : MV 上下限

16 : CT1 加热器断线/过电流

17 : CT1 加热器短路

18 : CT2 加热器断线/过电流

19 : CT2 加热器短路

20 :回路诊断 1

21 :回路诊断 2

22 :回路诊断 3

23 :报警 ( 状态 )

24 : READY ( 状态 )

25 : MANUAL ( 状态 )

26 :无效

27 : AT 启动中 ( 状态 )

28 : SP 斜坡中 ( 状态 )

29 :控制正动作 ( 状态 )

30 : ST 起动中 ( 状态 )

31 :无效

32 :定时器 ( 状态 )

33 : MFB( 马达反馈 ) 值上下限 ( 本机

无效 )

从右侧开始 1 、 2 、 3 、 4 位

0 :正

1 :逆

0 :无

1 :待机

2 :待机 +SP 变更时待机

0 :继续

1 :强制 OFF

0

从右侧开始 1 、 2 、 3 、 4 位

0 :无

1 :报警正+ OR 动作

2 :报警正+ AND 动作

3 :报警逆+ OR 动作

4 :报警逆+ AND 动作

0 :通常

1 : 事件设定值 ( 主 ) = 0 的场合、 事

件 OFF

0 : 0.1s

1 : 1s

2 : 1min

0

0

0000

0

0

0

0

0000

0

0

0

0

显示

级别

0

0

2

■ DI 分配库

库选择 : DI

显 示 dI1.1

~ dI3.1

项 目

内部接点 1 ~ 3

动作种类 dI1.2

~ dI3.2

内部接点 1 ~ 3

输入位运算

内 容

0 :无功能

1 : LSP 组选择 (0/ + 1)

2 : LSP 组选择 (0/ + 2)

3 : LSP 组选择 (0/ + 4)

4 :无效

5 :无效

6 :无效

7 : RUN/READY 切换

8 : AUTO/MANUAL 切换

9 :无效

10 : AT 停止 / 启动

11 : ST 禁止 / 启动

12 : 控制动作正逆切换 ( 与设定一致 /

与设定相反 )

13 : SP 斜坡许可 / 禁止

14 : PV 值保持 ( 不保持 / 保持 )

15 : PV 最大值保持 ( 不保持 / 保持 )

16 : PV 最小值保持 ( 不保持 / 保持 )

17 :定时器停止 / 启动

18 :全 DO 锁定解除除 ( 继续 / 解除 )

19 :无效

20 :无效

0 :不使用 ( 默认输入 )

1 :运算 1((A and B) or (C and D))

2 :运算 2((A or B) and (C or D))

3 :运算 3( A or B or C or D )

4 :运算 4( A and B and C and D )

初始值

0

0

显示

级别

0

2

显 示 dI1.3

~ dI3.3 dI1.4

~ dI3.4 dI1.5

~ dI3.5 dI1.6

~ dI3.6 dI1.7

~ dI3.7 dI1.8

~ dI3.8 dI1.9

~ dI3.9

项 目 内 容

内部接点

输入分配

内部接点

内部接点

内部接点

1

A

1

1

1

3

3

3

3

输入分配

输入分配

输入分配

B

C

D

0 :常开 (OFF 、 0)

1 :常闭 (ON 、 1)

2 : DI1

3 : DI2

4 ~ 9 :未定义

10 :内部事件 1

11 :内部事件 2

12 :内部事件 3

13 :内部事件 4

14 :内部事件 5

15 ~ 17 :未定义

18 :通讯 DI1

19 :通讯 DI2

20 :通讯 DI3

21 :通讯 DI4

22 : MANUAL 模式

23 : READY 模式

24 :未定义

25 : AT 启动中

26 : SP 斜坡中

27 :未定义

28 :有报警

29 :有 PV 报警

30 :未定义

31 : mode 键按键状态

32 :事件输出 1 端子状态

33 :控制输出 1 端子状态

内部接点 1 ~ 3 反转 A ~ D 从右侧开始 1 、 2 、 3 、 4 位

0 :不反转

1 :反转

第 1 位:反转 A

( 输入分配 A 反转 )

第 2 位:反转 B ( 输入分配

B 反转 )

第 3 位:反转 C

( 输入分配 C 反转 )

第 4 位:反转 D ( 输入分配

D 反转 )

内部接点 1 ~ 3 反转

内部接点

编号指定

1 ~ 3 内部事件

0 :不反转

1 :反转

0 :所有的内部事件

1 ~ 5 :内部事件编号

0

0

0

0000

0

0

0

初始值

2 ~ 4

0

0

0

显示

级别

2

2

2

2

2

2

2

■ DO 分配库

库选择 : DO

显 示 ot1.1

~ ot2.1

Ev1.1

Ev3.1

项 目

控制输出 1 ~ 2 、

事件输出 1 ~ 3 动作种类 ot1.2

~ ot2.2

Ev1.2

Ev3.2 ot1.3

~ ot2.3

Ev1.3

Ev3.3 ot1.4

~ ot2.4

Ev1.4

Ev3.4 ot1.5

~ ot2.5

Ev1.5

Ev3.5

控制输出 1 ~ 2 、

事件输出 1 ~ 3

输出分配 A

控制输出 1 ~ 2 、

事件输出 1 ~ 3

输出分配 B

控制输出 1 ~ 2 、

事件输出 1 ~ 3

输出分配 C

控制输出 1 ~ 2 、

事件输出 1 ~ 3

输出分配 D

内 容

0 :默认输出

1 : MV1(ON/OFF 控制输出、时间比

例输出、加热冷却控制的加热侧

时间比例输出 )

2 : MV2( 加热冷却控制的冷却侧时间

比例输出 )

3 :运算 1 ((A and B) or (C and D))

4 :运算 2 ((A or B) and (C or D))

5 :运算 3 (A or B or C or D)

6 :运算 3 (A and B and C and D)

0 :常开 (OFF 、 0)

1 :常闭 (ON 、 1)

2 :内部事件 1

3 :内部事件 2

4 :内部事件 3

5 :内部事件 4

6 :内部事件 5

7 ~ 13 :未定义

14 : MV1

15 : MV2

16 ~ 17 :未定义

18 : DI1

19 : DI2

20 ~ 25 :未定义

26 :内部接点 1

27 :内部接点 2

28 :内部接点 3

29 ~ 33 :未定义

34 :通讯 DI1

35 :通讯 DI2

36 :通讯 DI3

37 :通讯 DI4

38 : MANUAL 模式

39 : READY 模式

40 :未定义

41 : AT 启动中

42 : SP 斜坡中

43 :未定义

44 :有报警

45 :有 PV 报警

46 :未定义

47 : mode 键按键状态

48 :事件输出 1 端子状态

49 :控制输出 1 端子状态

初始值 显示

级别

0

14 ~ 15

2 ~ 4

0

0

0

2

2

2

2

2

C.LoC

L.LoC

PASS

PS1A

PS2A

PS1b

PS2b

显 示 ot1.6

~ ot2.6

Ev1.6

Ev3.6 ot1.7

~ ot2.7

Ev1.7

Ev3.7 ot1.8

~ ot2.8

Ev1.8

Ev3.8

项 目 内 容

控制输出 1 ~ 2 、事件 输

出 1 ~ 3 反转 A ~ D

第 1 位:反转 A

第 2 位:反转 B

第 3 位:反转 C

第 4 位:反转 D

控制输出 1 ~ 2 、事件

输出 1 ~ 3 反转

从右侧开始 1 、 2 、 3 、 4 位

0 :不反转

1 :反转

0 :不反转

1 :反转

控制输出 1 ~ 2 、事件 输

出 1 ~ 3 锁定

0 :无

1 :有 (ON 时锁定 )

2 : 有 (OFF 时锁定、电源投入初始化

时除外 )

■ 用户功能库

库选择 : UF

显 示

UF-1

UF-2

UF-3

UF-4

UF-5

UF-6

UF-7

UF-8

项 目

用户功能定义 1

用户功能定义 2

用户功能定义 3

用户功能定义 4

用户功能定义 5

用户功能定义 6

用户功能定义 7

用户功能定义 8

初始值

0000

0

0

0

0

0

显示

级别

2

2

0 2

内 容 初始值

各设定的第 1 显示部的显示,设定例

外的内容如下

----

:未登録

P--

:使用中 PID 组的比例带

I-:使用中 PID 组的积分时间 d--

:使用中 PID 组的微分时间 rE--

:使用中 PID 组的手动复位 oL--

:使用中 PID 组的操作量下限 oH--

PID 组的操作量上限

P--C

使用中 PID 组的冷却侧比例

I--C

: 使用中 PID 组的冷却侧积分 d--C

时间

: 使用中 PID 组的冷却侧微分 oL.-C

时间

: 使用中 PID 组的冷却侧操作 oh.-C

量下限

: 使用中 PID 组的冷却侧操作

量上限

- - - -

- - - -

- - - -

- - - -

- - - -

- - - -

- - - -

- - - -

显示

级别

1

1

1

1

1

1

1

1

■ 锁定库

库选择 : loc

显 示

LoC 键锁定

项 目

通讯锁定

设定器锁定

口令显示

口令 1A

口令 2A

口令 1B

口令 2B

■ 仪表信息库

库选择 : ID

显 示

Id01

Id02

Id03

Id04

Id05

Id06

项 目

ROMID

ROM 版本 1

ROM 版本 2

SLP 对应版本

EST 对应版本

日期代码 年

Id07

Id08

日期代码 月日

制造编号

内 容

0 :所有设定可能

1 : 模式、事件、运行显示、 SP 、

UF 、锁定、手动 MV 、 mode 键

的设定可能

2 : 运行显示、 SP 、 UF 、锁定、手

动 MV 、 mode 键的设定可能

3 : UF 、锁定、手动 MV 、 mode 键

的设定可能

0 : RS-485 通讯 read/write 可能

1 : RS-485 通讯 read/write 不可

0 :设定器通讯 read/write 可能

1 :设定器通讯 read/write 不可

0 ~ 15

5 :口令 1A ~ 2B 显示

0000 ~ FFFF (16 进制数 )

0000 ~ FFFF (16 进制数 )

0000 ~ FFFF (16 进制数 )

0000 ~ FFFF (16 进制数 )

初始值

0

0

0

0

0000

0000

0000

0000

显示

级别

0

2

2

0

0

0

0

0

内 容

0 固定

XX . XX ( 小数点以下 2 位 )

XX . XX ( 小数点以下 2 位 )

公历 -2000

例: 2003 年为「 3 」

月 +( 日 ÷ 100)

例: 12 月 1 日为「 12.01

初始值

2

2

2

显示

级别

2

2

2

2

2

基于SJ/T11364-2006「电子信息产品污染控制标识要求」

的表示式样

此标志表示电子信息产品的环保使用期限,适用于在中国销售的

产品,其依据是2006年2月28日公布的“电子信息产品污染控制管

要遵守此产品相关的安全及使用注意事项,在从生产日期开始的

标识年限内,便不会因产品中的有害物质发生泄漏或突然异变而

对环境、人体或财产造成重大影响。正当使用产品后实施废弃处

理时,请遵从电子信息产品的相关回收再利用法律法规。

          有毒害物质含有表示

零部件名称 铅

(Pb)

(Hg)

有毒害物质或元素

(Cd)

六价铬

(Cr 6+ )

多溴联苯

(PBB)

多溴二苯醚

(PBDE)

电路板组件*1 × ○ ○ ○ ○ ○

○ : 表示该部件的所有均质材料中,该有毒害物质含量均低于

SJ/T11363-2006标准所规定的限量要求。

× : 表示至少在该部件的一种以上的匀质材料中,该有毒害物质含量超过

SJ/T11363-2006标准所规定的限量要求。

*1 : 电路板组件包括印刷电路板及其构成的零部件,如电阻、电容、集成

电路、连接器等。

注意 : 没有记载于零部件名称的部件的均质材料中,该有毒害物质含量

均低于SJ/T11363-2006标准所规定的限量要求。

本资料所记内容如有变更恕不另行通知

阿自倍尔株式会社

Advanced Automation Company

阿自倍尔自控工程

(

上海

)

有限公司

总 部 上海市徐汇区柳州路 928 号百丽国际广场 12F

邮编 : 200235  

电话 : 021-50905580  传真 : 021-50909625

2015 年 2 月中文第 13 版

C7 C4

■ 事件组态库

库选择 : EVCF

显 示

E1.C1

E5.C1

E1.C2

E5.C2

E1.C3

E5.C3

项 目

内部事件 1 ~ 5 组态 1

动作种类

内部事件

1

2

1 ~

位:正逆

位:待机

5 组态 2

第 3 位: READY 时动作

第 4 位:未定义

内部事件 1 ~ 5 组态 3

第 1 位:报警 OR

2

3

4

位:特殊 OFF

位:延时时间单位

位:未定义

内 容 初始值

0 :无事件

1 : PV 上限

2 : PV 下限

3 : PV 上下限

4 :偏差上限

5 :偏差下限

6 :偏差上下限

7 :偏差上限 ( 最终 SP 基准 )

8 :偏差下限 ( 最终 SP 基准 )

9 :偏差上下限 ( 最终 SP 基准 )

10 : SP 上限

11 : SP 下限

12 : SP 上下限

13 : MV 上限

14 : MV 下限

15 : MV 上下限

16 : CT1 加热器断线/过电流

17 : CT1 加热器短路

18 : CT2 加热器断线/过电流

19 : CT2 加热器短路

20 :回路诊断 1

21 :回路诊断 2

22 :回路诊断 3

23 :报警 ( 状态 )

24 : READY ( 状态 )

25 : MANUAL ( 状态 )

26 :无效

27 : AT 启动中 ( 状态 )

28 : SP 斜坡中 ( 状态 )

29 :控制正动作 ( 状态 )

30 : ST 起动中 ( 状态 )

31 :无效

32 :定时器 ( 状态 )

33 : MFB( 马达反馈 ) 值上下限 ( 本机

无效 )

从右侧开始 1 、 2 、 3 、 4 位

0 :正

1 :逆

0 :无

1 :待机

2 :待机 +SP 变更时待机

0 :继续

1 :强制 OFF

0

从右侧开始 1 、 2 、 3 、 4 位

0 :无

1 :报警正+ OR 动作

2 :报警正+ AND 动作

3 :报警逆+ OR 动作

4 :报警逆+ AND 动作

0 :通常

1 : 事件设定值 ( 主 ) = 0 的场合、 事

件 OFF

0 : 0.1s

1 : 1s

2 : 1min

0

0

0000

0

0

0

0

0000

0

0

0

0

显示

级别

0

0

2

■ DI 分配库

库选择 : DI

显 示 dI1.1

~ dI3.1

项 目

内部接点 1 ~ 3

动作种类 dI1.2

~ dI3.2

内部接点 1 ~ 3

输入位运算

内 容

0 :无功能

1 : LSP 组选择 (0/ + 1)

2 : LSP 组选择 (0/ + 2)

3 : LSP 组选择 (0/ + 4)

4 :无效

5 :无效

6 :无效

7 : RUN/READY 切换

8 : AUTO/MANUAL 切换

9 :无效

10 : AT 停止 / 启动

11 : ST 禁止 / 启动

12 : 控制动作正逆切换 ( 与设定一致 /

与设定相反 )

13 : SP 斜坡许可 / 禁止

14 : PV 值保持 ( 不保持 / 保持 )

15 : PV 最大值保持 ( 不保持 / 保持 )

16 : PV 最小值保持 ( 不保持 / 保持 )

17 :定时器停止 / 启动

18 :全 DO 锁定解除除 ( 继续 / 解除 )

19 :无效

20 :无效

0 :不使用 ( 默认输入 )

1 :运算 1((A and B) or (C and D))

2 :运算 2((A or B) and (C or D))

3 :运算 3( A or B or C or D )

4 :运算 4( A and B and C and D )

初始值

0

0

显示

级别

0

2

显 示 dI1.3

~ dI3.3 dI1.4

~ dI3.4 dI1.5

~ dI3.5 dI1.6

~ dI3.6 dI1.7

~ dI3.7 dI1.8

~ dI3.8 dI1.9

~ dI3.9

项 目 内 容

内部接点

输入分配

内部接点

内部接点

内部接点

1

A

1

1

1

3

3

3

3

输入分配

输入分配

输入分配

B

C

D

0 :常开 (OFF 、 0)

1 :常闭 (ON 、 1)

2 : DI1

3 : DI2

4 ~ 9 :未定义

10 :内部事件 1

11 :内部事件 2

12 :内部事件 3

13 :内部事件 4

14 :内部事件 5

15 ~ 17 :未定义

18 :通讯 DI1

19 :通讯 DI2

20 :通讯 DI3

21 :通讯 DI4

22 : MANUAL 模式

23 : READY 模式

24 :未定义

25 : AT 启动中

26 : SP 斜坡中

27 :未定义

28 :有报警

29 :有 PV 报警

30 :未定义

31 : mode 键按键状态

32 :事件输出 1 端子状态

33 :控制输出 1 端子状态

内部接点 1 ~ 3 反转 A ~ D 从右侧开始 1 、 2 、 3 、 4 位

0 :不反转

1 :反转

第 1 位:反转 A

( 输入分配 A 反转 )

第 2 位:反转 B ( 输入分配

B 反转 )

第 3 位:反转 C

( 输入分配 C 反转 )

第 4 位:反转 D ( 输入分配

D 反转 )

内部接点 1 ~ 3 反转

内部接点

编号指定

1 ~ 3 内部事件

0 :不反转

1 :反转

0 :所有的内部事件

1 ~ 5 :内部事件编号

0

0

0

0000

0

0

0

初始值

2 ~ 4

0

0

0

显示

级别

2

2

2

2

2

■ DO 分配库

库选择 : DO

显 示 ot1.1

~ ot2.1

Ev1.1

Ev3.1

项 目

控制输出 1 ~ 2 、

事件输出 1 ~ 3 动作种类 ot1.2

~ ot2.2

Ev1.2

Ev3.2 ot1.3

~ ot2.3

Ev1.3

Ev3.3 ot1.4

~ ot2.4

Ev1.4

Ev3.4 ot1.5

~ ot2.5

Ev1.5

Ev3.5

控制输出 1 ~ 2 、

事件输出 1 ~ 3

输出分配 A

控制输出 1 ~ 2 、

事件输出 1 ~ 3

输出分配 B

控制输出 1 ~ 2 、

事件输出 1 ~ 3

输出分配 C

控制输出 1 ~ 2 、

事件输出 1 ~ 3

输出分配 D

内 容

0 :默认输出

1 : MV1(ON/OFF 控制输出、时间比

例输出、加热冷却控制的加热侧

时间比例输出 )

2 : MV2( 加热冷却控制的冷却侧时间

比例输出 )

3 :运算 1 ((A and B) or (C and D))

4 :运算 2 ((A or B) and (C or D))

5 :运算 3 (A or B or C or D)

6 :运算 3 (A and B and C and D)

0 :常开 (OFF 、 0)

1 :常闭 (ON 、 1)

2 :内部事件 1

3 :内部事件 2

4 :内部事件 3

5 :内部事件 4

6 :内部事件 5

7 ~ 13 :未定义

14 : MV1

15 : MV2

16 ~ 17 :未定义

18 : DI1

19 : DI2

20 ~ 25 :未定义

26 :内部接点 1

27 :内部接点 2

28 :内部接点 3

29 ~ 33 :未定义

34 :通讯 DI1

35 :通讯 DI2

36 :通讯 DI3

37 :通讯 DI4

38 : MANUAL 模式

39 : READY 模式

40 :未定义

41 : AT 启动中

42 : SP 斜坡中

43 :未定义

44 :有报警

45 :有 PV 报警

46 :未定义

47 : mode 键按键状态

48 :事件输出 1 端子状态

49 :控制输出 1 端子状态

初始值 显示

级别

0

14 ~ 15

2 ~ 4

0

0

0

2

2

2

2

2

2

2

C4

C.LoC

L.LoC

PASS

PS1A

PS2A

PS1b

PS2b

显 示 ot1.6

~ ot2.6

Ev1.6

Ev3.6 ot1.7

~ ot2.7

Ev1.7

Ev3.7 ot1.8

~ ot2.8

Ev1.8

Ev3.8

项 目 内 容

控制输出 1 ~ 2 、事件 输

出 1 ~ 3 反转 A ~ D

第 1 位:反转 A

第 2 位:反转 B

第 3 位:反转 C

第 4 位:反转 D

控制输出 1 ~ 2 、事件

输出 1 ~ 3 反转

从右侧开始 1 、 2 、 3 、 4 位

0 :不反转

1 :反转

0 :不反转

1 :反转

控制输出 1 ~ 2 、事件 输

出 1 ~ 3 锁定

0 :无

1 :有 (ON 时锁定 )

2 : 有 (OFF 时锁定、电源投入初始化

时除外 )

■ 用户功能库

库选择 : UF

显 示

UF-1

UF-2

UF-3

UF-4

UF-5

UF-6

UF-7

UF-8

项 目

用户功能定义 1

用户功能定义 2

用户功能定义 3

用户功能定义 4

用户功能定义 5

用户功能定义 6

用户功能定义 7

用户功能定义 8

初始值

0000

0

0

0

0

0

显示

级别

2

2

0 2

内 容 初始值

各设定的第 1 显示部的显示,设定例

外的内容如下

----

:未登録

P--

:使用中 PID 组的比例带

I-:使用中 PID 组的积分时间 d--

:使用中 PID 组的微分时间 rE--

:使用中 PID 组的手动复位 oL--

:使用中 PID 组的操作量下限 oH--

PID 组的操作量上限

P--C

使用中 PID 组的冷却侧比例

I--C

: 使用中 PID 组的冷却侧积分 d--C

时间

: 使用中 PID 组的冷却侧微分 oL.-C

时间

: 使用中 PID 组的冷却侧操作 oh.-C

量下限

: 使用中 PID 组的冷却侧操作

量上限

- - - -

- - - -

- - - -

- - - -

- - - -

- - - -

- - - -

- - - -

显示

级别

1

1

1

1

1

1

1

1

■ 锁定库

库选择 : loc

显 示

LoC 键锁定

项 目

通讯锁定

设定器锁定

口令显示

口令 1A

口令 2A

口令 1B

口令 2B

■ 仪表信息库

库选择 : ID

显 示

Id01

Id02

Id03

Id04

Id05

Id06

项 目

ROMID

ROM 版本 1

ROM 版本 2

SLP 对应版本

EST 对应版本

日期代码 年

Id07

Id08

日期代码 月日

制造编号

内 容

0 :所有设定可能

1 : 模式、事件、运行显示、 SP 、

UF 、锁定、手动 MV 、 mode 键

的设定可能

2 : 运行显示、 SP 、 UF 、锁定、手

动 MV 、 mode 键的设定可能

3 : UF 、锁定、手动 MV 、 mode 键

的设定可能

0 : RS-485 通讯 read/write 可能

1 : RS-485 通讯 read/write 不可

0 :设定器通讯 read/write 可能

1 :设定器通讯 read/write 不可

0 ~ 15

5 :口令 1A ~ 2B 显示

0000 ~ FFFF (16 进制数 )

0000 ~ FFFF (16 进制数 )

0000 ~ FFFF (16 进制数 )

0000 ~ FFFF (16 进制数 )

初始值

0

0

0

0

0000

0000

0000

0000

显示

级别

0

2

2

0

0

0

0

0

内 容

0 固定

XX . XX ( 小数点以下 2 位 )

XX . XX ( 小数点以下 2 位 )

公历 -2000

例: 2003 年为「 3 」

月 +( 日 ÷ 100)

例: 12 月 1 日为「 12.01

初始值

2

2

2

显示

级别

2

2

2

2

2

基于SJ/T11364-2006「电子信息产品污染控制标识要求」

的表示式样

此标志表示电子信息产品的环保使用期限,适用于在中国销售的

产品,其依据是2006年2月28日公布的“电子信息产品污染控制管

要遵守此产品相关的安全及使用注意事项,在从生产日期开始的

标识年限内,便不会因产品中的有害物质发生泄漏或突然异变而

对环境、人体或财产造成重大影响。正当使用产品后实施废弃处

理时,请遵从电子信息产品的相关回收再利用法律法规。

          有毒害物质含有表示

零部件名称 铅

(Pb)

(Hg)

有毒害物质或元素

(Cd)

六价铬

(Cr 6+ )

多溴联苯

(PBB)

多溴二苯醚

(PBDE)

电路板组件*1 × ○ ○ ○ ○ ○

○ : 表示该部件的所有均质材料中,该有毒害物质含量均低于

SJ/T11363-2006标准所规定的限量要求。

× : 表示至少在该部件的一种以上的匀质材料中,该有毒害物质含量超过

SJ/T11363-2006标准所规定的限量要求。

*1 : 电路板组件包括印刷电路板及其构成的零部件,如电阻、电容、集成

电路、连接器等。

注意 : 没有记载于零部件名称的部件的均质材料中,该有毒害物质含量

均低于SJ/T11363-2006标准所规定的限量要求。

C8

本资料所记内容如有变更恕不另行通知

阿自倍尔株式会社

Advanced Automation Company

阿自倍尔自控工程

(

上海

)

有限公司

总 部 上海市徐汇区柳州路 928 号百丽国际广场 12F

邮编 : 200235  

电话 : 021-50905580  传真 : 021-50909625

2015 年 2 月中文第 13 版

advertisement

Related manuals

Download PDF

advertisement