Gophert CPS Series, CPS-6011 User Manual
Gophert CPS Series is a compact and powerful DC power supply with a microprocessor control unit and digital meters for voltage, current, and power. It features multiple protection functions, including over voltage, over current, over temperature, and short circuit protection, ensuring safe and reliable operation. The CPS Series is ideal for a wide range of applications, including powering sensitive electronic devices, charging batteries, and testing electrical circuits.
Advertisement
Advertisement
User Manual
Compact DC Power Supply
CPS Series
Safety Regulations
EN
Safety Regulations
To avoid electrical shock, non-authorized person of our company is not allowed to open the cabinet.
It is forbidden to use this product for life support system or any other devices with high safety requirements.
We are not responsible for any direct or indirect financial damage that might occur when using the power supply.
Warranty
This hardware product is warranted against defects in material and workmanship for a period of two years from date of delivery.
For warranty service, this product must be returned to a service facility designated by our company. Customer shall prepay one-way freight for products returned to our place for warranty service. Our company shall pay for return of products to customer. Customer shall pay all freight, duty and taxes if the product is back from foreign countries for repair.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the customer, customer-supplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or improper site preparation and maintenance, installing circuit by the customer or using their own product, changing, deleting, removing or unrecognizing the product model or serial number, accident including but not limited to lightning stroke, water, fire, misuse or neglect.
WARNING
Do not use this power supply near water.
Do not operate or touch this power supply with wet hands.
Do not open the casing of the power supply when it is connected to ac mains.
CAUTION
Use a grounded 3 pin AC source.
This unit is for indoor use only.
Do not operate or place this unit in a humid, dusty, in direct sunlight location or near any heat source.
Before plugging into local AC mains, carefully to set the switch according to the AC input Voltage.
Do not block any ventilation openings of the unit.
This unit must be used within the specified rating; regular excessive continuous loading may cause damage to the power supply.
1
Table of Contents
EN
Contents
1 Product Features ....................................................................................................................... 3
2 Panel Layout .............................................................................................................................. 4
3 Function and Operation ............................................................................................................ 6
3.1 Select Operation Voltage ............................................................................................... 6
3.2 Set the output current .................................................................................................. 6
3.3 Turn on or turn off output ............................................................................................. 6
3.4 Set the output on at the AC power on .......................................................................... 7
3.5 Lock ............................................................................................................................... 7
3.6 Display the output power.............................................................................................. 7
4 Protection .................................................................................................................................. 7
4.1 Over Voltage Protection ................................................................................................ 7
4.2 Over Current Protection ................................................................................................ 7
4.3 Over temperature protection ........................................................................................ 8
5 Application ................................................................................................................................ 8
2
Product Features
EN
1 Product Features
Top performance cost ratio
High power density, smallest and compact
Full metal enclosure with very low EMI
The microprocessor(MCU) control
Using Encoder to set the voltage and current
Four digital volt meter and current meter
High efficiency, up to 90%.
Low Ripple & Noise: 30 mVp-p.
Output ON/OFF
Lock switch
Intelligent protection: Tracking OVP, Tracking OCP, OTP,
Output short circuit protection
3
Function and Operation
2 Panel Layout
EN
4
Function and Operation
EN
3
4
5
6
No.
1
2
7
8
9
10
11
12
13
14
Name
Volt meter
Current meter
Constant voltage indicator
Constant current indicator
Watt indicator
LOCK
indicator
Voltage/Current select button
Shown in diagram or State
Function
Display the setting voltage or the actual output voltage
Display the setting current or the actual output current output state(OFF OVP OCP OTP)
Turn ON/OFF Turn ON—
Constant voltage state
Turn ON/OFF Turn ON—
Constant current state
Turn ON/OFF Display output power
Turn ON/OFF Indicate the LOCK state
‘V’ indicator turns on for adjusting voltage
‘A’ indicator turns on for adjusting current
Rotation
—increase or decrease
Adjusting Knob
Power Switch
LOCK button
WATT Button
ON/OFF button
Output Terminal
AC Socket
Push— Coarse/Fine
Power ON/OFF
Click, lock/unlock. In the lock state(Lock light is on) adjusting knob and ON/OFF button can’t change output state.
Click, digital tube of ammeter highlights the current output power and light is on.
Restore the current display automatically after display lasts 5 seconds.
Click—output on or output off
Press it for 5 seconds to set the output on at turn on the power supply.
Red—Output ‘+’/ Black—Output ‘-’
AC Input Socket
5
Function and Operation
3 Function and Operation
3.1
Select Operation Voltage
EN
Click the adjusting selective button to “V” indicator turns on, click the adjusting knob, the volt meter display the set voltage and the adjustable position highlight as fig1, the highlight will shift from right to left when user clicks the knob continually. Then adjust the knob to set the highlight number.
For example: Set the output voltage is 24.15V. At first, click the knob, the rightmost position of the volt meter highlight, adjust the knob to set the highlight number to 5, then click the knob again the highlight will shift to left, adjust the knob to set the highlight number to 1, then set the highlight number to 4 and 2 in the same way, finally the output voltage is set to 24.15V.
3.2
Set the output current
fig1
Click the adjusting selective button to “A” indicator turns on, click the knob the Ammeter display the set current, the operation is same as setting voltage.
3.3
Turn on or turn off output
When the output is turned off, the ammeter highlights “OFF” Click “ON/OFF ” button off.
the output turned on. Then click the button again the output turned
6
Function and Operation
3.4
Set the output on at the AC power on
EN
Press “ ON/OFF ” button for 5 seconds, ammeter highlights “ dOn ” for 2 seconds, the output is set to on at the AC power on. To cancel this function, press
“ ON/OFF ” “ dOF ” output is off at the AC power on.
3.5
Lock
Click “ Lock ” button the “Lock” indicator turns on, ON/OFF button and adjusting knob are locked. To cancel the function please click the “ Lock ” button again and the lock light turns off.
3.6
Display the output power
Click “ WATT ” button output power for 3 seconds.
, the “Watt” indicator light turns on and ammeter highlights the
4 Protection
4.1
Over Voltage Protection
MCU controls the tracking OVP, OVP value is relevant to the setting voltage, this function protect the appliance which connected to the power supply safely.
When OVP is triggered MCU shut down the output and the ammeter highlights
“ OUP ” . Press ON/OFF button to reset the OVP if the over voltage problem has been resolved.
4.2
Over Current Protection
MCU control the tracking OCP, OCP value is relevant to the setting current. This power supply can operate constant current mode, so if the C.C works normally the
7
Function and Operation
EN
OCP never be triggered; However if the C.C works abnormally the tracking OCP will protect the appliance which connected to the power supply safely. When OCP is triggered, MCU shut down the output and ammeter highlights
“
OCP
”
, press ON/OFF button to reset the OCP if the over current problem has been detected.
4.3
Over temperature protection
The MCU monitor the temperature of the power supply, if the temperature is higher than the special value MCU shut down the output and ammeter highlights
“ OTP ” , press ON/OFF button to reset the OTP if the temperature lowered.
5 Application
5.1
Series Connection
Several units can be connected in series in order to gain a higher total output voltage. To do so, the positive DC output of one unit is connected to the negative DC output of the next unit etc. The non-connected positive and negative of the last unit will be the positive and negative of the whole series output, and will have the high voltage output.
In view of safety and insulation, it is not allowed to connect an arbitrary number of units in series. The DC output of series system must not be raised higher than
500 V DC.
If units with different nominal current are connected in series, the minimum nominal current of the products is the maximum current of the system.
In a series connection, only negative DC output of one unit (the one with negative DC output in the series system) may be grounded.5.2 Parallel
Connection
Several units which are preferably same type, but at least identical nominal output voltage, can be connected in parallel in order to gain a higher total output voltage. It is recommended to adjust the output current to the maximum and the output voltage to identical value on every unit.
Gopher Technology co, LIMITED
Factory
Add.: No. 71 Zhentian Bei Rd., Yantian, Fenggang Town, Dongguan, Guangdong,
China
Mobile: +86-13392313910
Web http://www.gophertc.com
8
Download