Astria Montebello ST Direct Vent Gas Fireplace Specification
Add to My manuals2 Pages
Astria MONTEBELLO ST, a vented gas fireplace, offers a range of features for versatile use and efficient heating. It boasts variable heat output from 37,000 to 57,000 BTU/HR, allowing you to customize warmth to your liking. With its power vent system, the fireplace efficiently expels fumes, making it suitable for both indoor and outdoor installations. Installation flexibility is enhanced by its compatibility with various vent configurations, including vertical, horizontal, and elbow setups.
advertisement
MONTEBELLO™ ST-PV-B
A B C D E in 52-1/8
(mm) (1324)
47-3/8
(1203)
99-1/2
(2527)
26-3/8 6
(670) (152)
Framing Should be constructions of 2 x 4 or larger lumber.
10-1/2
(267) INDOOR /
OUTDOOR 12-1/8
(308)
Inches
(millimeters)
5-1/8
(130)
SEE-THROUGH
DIRECT-VENT FIREPLACE
12-1/8
(308)
Inches
(millimeters)
5-1/8
(130)
10-1/2
(267)
INDOOR /
INDOOR
INTERIOR
Wall Stud
Combustible
Finished Wall
Materials
Header
3" Min.
(76 mm)*
1"
(25.4mm)
Minimum
Adaptor Plus 4
Feet Vertical
Vent (Min.)
& 90° Elbow
B
C C
Combustible materials are allowed above this point on the face of the appliance.
Top of
Appliance
B
~
D
A
1-1/2
(38)
D
A
INDOOR SIDE
NOTE: For indoor/outdoor installations, the control side of the fireplace must be installed on the indoor side.
E
Dimension
Dimension
OUTDOOR SIDE
is from fireplace base to top framing member.
is from fireplace base to centerline of horizontal vent pipe.
Minimum vent framing: Adaptor plus 4 ft vertical vent and one
90-degree elbow. For other venting configurations, see the and Operation Manual .
inches
(millimeters)
Installation
1/2” board for platform (shown in gray).
Dimension is a 6” clearance from
25-3/8
(645) fireplace base to outdoor surface (e.g., deck, patio, lanai) that is required as a moisture barrier (not a combustible
8"/11" *
Vent/Intake inches
(millimeters)
25-3/8
(645)
8"/11" *
Vent/Intake
Vent Size
Co-axial DV Collar on Fireplace -
8" Inner / 11" Outer
Adaptor Probe
Reduces Vent Size To -
4-1/2" Inner / 7-1/2" Outer inches
(millimeters) inches
(millimeters)
27-1/2
(699)
3-1/2
(89)
3-1/2
(89)
26-1/4
(667)
13-1/8
(333)
13-1/8
(333)
5-1/2
(140)
5-1/2
(140)
7-3/8
(187)
Top View
7-3/8
(187)
*Adaptor with Probe required to transition from
8"/11" fireplace vent collar to 4-1/2"/7-1/2" venting.
*Adaptor with Probe required to transition from
8"/11" fireplace vent collar to 4-1/2"/7-1/2" venting.
inches
Top View
34-3/4 inches
(millimeters)
12-3/8
12-3/8
(314)
34-3/4
(883)
5-1/8
5-1/8
(130)
46-5/8
(1184)
46-5/8
(1184)
7 (178)
7 (178)
29-5/8
(753)
Spacers
Top of Door Frame
FIREPLACE
(side view)
* Insulation is NOT ALLOWED in the clearance zones around vent components. Keep this area free from combustible materials.
3" Min.
(76 mm)*
EXTERIOR
Adaptor Plus 4
Feet Vertical
Vent (Min.)
& 90° Elbow
1"
(25.4mm)
Minimum
Top of
Appliance
Spacers
Top of Door Frame
Wall Stud
Sheathing,
Combustible
Header
Non-Combustible
Sheathing Required
Below This Point
Non-Combustible
Extend Housewrap
(building paper) to this point
Note: Non-Combustible
Sheathing and building paper should extend to u-channels on sides and bottom.
FIREPLACE
(side view)
19-5/8
(499)
Control Switch
19-5/8
(499)
Control Switch
Wires Knock-Out
J-Box
J-Box
Left Side View
Left Side View
Unit Dimensions
(Shown with Outdoor Kit Installed)
50-1/2
Front View (opposite valve access side)
Front View (opposite valve access side)
Fireplace Dimensions
Fireplace Dimensions
(shown with Outdoor Kit installed)
P/N 901137-00, REV. NC, 01/2021
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 1 of 2
MONTEBELLO™ ST-PV-B
Product Reference Information
Cat.# Model
F4691 MONTEBELLO STTYN-B
Ship.Wt.
383 lb.
Ship. Volume
52.2 cu. ft.
Outdoors
Indoors
Top View
When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit.
Drywall
Listed by PFS Corporation to to
ANSI Z21.88 (in Canada, CSA-
2.33), and CAN/CGA-2.17-M91
(CSA P4.1) in both USA and
Canada, as a vented gas fireplace.
C
PFS
®
US
Report No. F14-107
Natural Gas
Model
MontebelloSTTYN-B
Input (BTU/HR)
37,000 TO 57,000
Power Vent Venting Chart
Maximum Number Of Elbows
Maximum Feet Of Run
Minimum Horizontal Run
Minimum Vertical Run
Maximum Vertical Rise
-
A + B
B
A
A
6
110 feet
10 feet
Adaptor Plus 4 Feet Vertical
Vent (Min.) and 90° Elbow
66 feet
Minimum Clearances To Combustibles
Vertical Vent Pipe
Horizontal Vent Pipe
1” (26 mm)
Top - 3” (77 mm)
Sides - 1” (26 mm)
Bottom - 1” (26 mm)
B
A
(See Chart)
Probe Adaptor
(Required)
MANTEL CLEARANCES
Inches (mm)
12 (305) MANTEL
10 (254) MANTEL
8 (203) MANTEL
6 (152) MANTEL
17
(432)
15
(381)
13
(330)
11
(279) 9
(229) 7
(178)
4 (102) MANTEL
2 (51) MANTEL
Top of Appliance
TOP OF
APPLIANCE
Firestop/Spacer (SV4.5HF) shown on the exterior side of the wall.
10-1/2"
(267 mm)
12-1/8"
(308 mm)
5-1/8"
(130 mm)
7"
(178)
Clearances from any projections such as shelves, window sills, mantels, etc. above the appliance
Power Vent
Termination
3"
(77 mm)
Adaptor
SV4.5RCH
1"
(26 mm)
6 to 48” Vent Section,
Telescopic vent section,
Elbow or Appliance Collar
Note: Centerline of Vent Piping is
NOT the Same as the Centerline of the Frame Opening.
See Page 1 for Minimum
Distance to Base of Appliance
Base of Appliance
Printed in U.S.A. © 2015 Innovative Hearth Products
P/N 901137-00, REV. NC, 01/2021
Fireplace
Horizontal
Termination
Venting Can Run Up To 3 ft Below Unit
At 14" minimum side wall clearance, a combustible wall can project to any length.
At 8-1/4" side wall clearance, a combustible wall can project 12"
1/2"
(13)
Top View of
Fireplace
45 °
5 (127)
Combustible Materials
Allowed In Shaded Area
“Safe Zone”
Combustible Walls shown in dark gray
12 (305)
17 (432)
Combustible materials may project beyond the sides of the fireplace opening as long as they are kept within the shaded areas illustrated here.
8-1/4
(209)
Protected wall shown in white 14
(356)
Minimum Clearances -
Inches (millimeters)
Back / Sides 0 (0) Spacers/Standoffs
Floor
Bottom of Appliance To Ceiling
Vent
0 (0)
72 (1829)
3 (76) Top, 1 (25) Sides & Bottom
NOTE: Diagrams, illustrations and photographs are not to scale
– consult installation instructions. Product designs, materials, dimensions, specifications, colors and prices are subject to change or discontinuance without notice.
Page 2 of 2
advertisement