SteriPEN Journey User Guide

Add to my manuals
5 Pages

advertisement

SteriPEN Journey User Guide | Manualzz

SteriPEN™ Journey

LCD

User’s Guide

Instructions for Using Journey

LCD

Thank you for buying SteriPEN™ Journey LCD , and congratulations on your purchase. The new

LCD (Liquid Crystal Display) screen uses universal symbols, providing the user with added confidence and enhancing ease of use. Years of careful research, development and testing have gone into the creation of this unique product.

Directions for Use 40 C.F.R. §156.10(i)(2)

It is a violation of Federal law to use this product in a manner inconsistent with its labeling.

40 C.F.R. §156.10(i)(2)(ii)

SteriPEN™ exceeds U.S. EPA Guide Standard and Protocol for Testing Microbiological Water Purifiers, destroying over 99.9999% of bacteria,

99.99% of viruses, and 99.9% of protozoa when used as directed. SteriPEN™ is not a sterilizer.

Distributors / Importers

U.S.A.

Hydro-Photon, Inc.

P.O. Box 675

262 Ellsworth Rd.

Blue Hill, Maine 04614 USA

Toll-Free: (888) 783-7473

Tel: (207) 374-5800

Fax: (207) 374-5100 [email protected]

www.steripen.com

France

Top Rock

RN 532 - N° 11

26300 Pizançon, France

Tél: +33 4 75 02 77 60

Fax: +33 4 75 05 16 42 [email protected]

Australia

Sea To Summit

6 Brown St.

East Perth

Western Australia 6004

Toll Free: (800) 787-677

Tel: +61 8 9221 6617

Fax: +61 8 9221 6618 [email protected]

www.seatosummit.com.au

Canada

Blue River Trading, Ltd.

16-240 Viceroy Rd.

Concord, Ontario L4K-3N9

Canada

Tel: (905) 738-9401

Fax: (905)738-8145 [email protected]

www.bluerivertrading.com

Denmark

Army Wear (Retailer)

Hobrovej 825

DK9230 Denmark

Tel: +45 9838 2319

Fax: +45 9838 3219

[email protected]

www.armywear.dk

Finland

Vandernet Oy

Palkaneentie 19A

00510 Helsinki Finland

Tel: +358-20-741 8333

Fax: +358-20-741 8346 [email protected]

www.vandernet.com

Hong Kong

Sunmark Camping Equipment Co. (Retailer)

1/Fl., 121 Wanchai Rd.

Wanchai, Hong Kong

Tel: +852-2893-8553

Fax: +852-2893-9597 [email protected]

Japan

A & F Corporation

1-1-7, Okubo, Shinjuku-ku

Tokyo 169-0072 Japan

Tel: 81-3-3209-8824

Fax: 81-3-3209-7497 www.aandf.co.jp

[email protected]

Nepal

Peak Promotion

Trading Pvt. Ltd.

Brahama kumari marga,

House No. 85

Thamel, Kathmandu, Nepal

Tel: 977-1-4249454

Fax: 977-1-4245137 [email protected]

The Netherlands (Holland, Belgium and Luxemburg)

Technolyt

Industrieweg 35

1521NE Wormerveer, Holland

Tel: +31 75-6474547

Fax: +31 75-6213663 [email protected]

www.technolyt.nl

New Zealand

Outfitters

Runciman Road

RD 2, Pukekohe East

New Zealand

Tel: +64 9 238 4571

Fax: +64 9 238 4575 [email protected]

Saudi Arabia

Blue Camp

323 Alkhobar Mall

Alkhobar City, Eastern

Province 31952

Tel: +96 63 8877294

Fax: +96 63 8877295 [email protected]

www.blue-camp.com

Singapore

Outdoor Life Pte Ltd

Novena Square

238 Thomson Road #20-60/67

Singapore 307683

Tel: +65 6255-4814

Fax: +65 6255-4816

[email protected]

www.outdoorlife.com.sg

South Africa

Ram Mountaineering

Unit 14 Old Mill Park

Old Mill Way, Ndebeni

Cape Town, South Africa

Tel: +27 21 532 0549

Fax: +27 21 531 2844 [email protected]

www.rammountain.co.za

Sweden

Skridskobolaget Devex AB

Fraktflygaregatan 3

SE-128 30 Skarpnäck Sweden

Tel: +46 8 683 75 03

Fax: +46 8 683 75 99 [email protected]

Switzerland, Germany and Austria

Exped AG

Hardstrasse 81

CH-8004 Zurich

Switzerland

Tel: +41 1 497 10 10

Fax: +41 1 497 10 11 [email protected]

www.exped.com

Turkey

TBS Consultancy Limited

Piyade Sokak 18/10

Cankaya, Ankara, Turkey

Tel: +90 312-442-50-83

Fax: +90 312-440-06-30 [email protected]

United Kingdom

Rosker Ltd.

13 Quay Lane

Gosport

Hampshire, PO12 4LJ

Great Britain

Tel: +44 2392 528711

Fax: +44 2392 529108 [email protected]

www.rosker.co.uk

Duty Free

Sea & Sky Supply

PO Box 3119

3301 DC Dordrecht

Rijksstraatweg 7, 3316 EE

The Netherlands

Tel: +31 78 65 34 580

Fax: +31 78 65 34 581 [email protected]

www.seasky.com

© 2008 Hydro-Photon, Inc.

All rights reserved.

© 2008 Hydro-Photon, Inc.

Alle Rechte vorbehalten.

© 2008 Hydro-Photon, Inc.

Todos los derechos reservados

© 2008 Hydro-Photon, Inc.

Tous droits réservés.

S

K

Operating the SteriPEN™ Journey

LCD

Quick Start Guide

Use SteriPEN ™ Journey LCD with clear water. Discolored or dirty water should be pre-filtered until clear prior to Journey LCD treatment.

SteriPEN ™ Journey LCD treats two ranges of water volume:

A—up to 0.5 L (16 fl. oz.)

B—between 0.5 – 1 L (16 – 32 fl. oz.)

1

2

3

4

5

6

1 Insert 2 CR123 batteries with polarities as shown. Note: Tighten screw on battery end cap until snug. Do not over-tighten screw as this may cause damage.

2 Remove lamp cover.

Note: Sensors must be dry.

3A Push On/Off button twice for up to 0.5 L

(16 fl. oz.) – LCD display will show timer ring and 1/2 L treatment volume selected, indicating Journey LCD is ready to use.

Note: On/Off button must be pushed before lamp is immersed in water, or

Journey LCD will not function.

3B Push On/Off button once for 0.5 - 1L

(16 - 32 fl. oz.) – LCD display will show timer ring and 1 L treatment volume selected, indicating Journey LCD is ready to use.

Note: On/Off button must be pushed before lamp is immersed in water, or

Journey LCD will not function.

4 While LCD display is on, dip the ultraviolet

(UV) lamp into the water to be treated so that lamp and water sensors are completely immersed. When water is detected, lamp turns on automatically, emitting both UV and visible light. When lamp comes on the timer is visible in the upper display. Timer ring fills in as the dose proceeds. Countdown timer is visible inside the ring showing the number of seconds remaining to complete the dose. Note: If visible light is not evident, the Journey LCD lamp is not on, and water should not be consumed.

5 During treatment, agitate the water by stirring with the Journey LCD until the lamp automatically turns off. When lamp turns off, LCD displays both Dose

Status Successful and Battery Status symbols to show that the UV dose is complete. Note: If dose fails, see operating symbols and signals below.

6 Remove the Journey LCD lamp from water. Dry off lamp and water sensors with clean cloth. Replace lamp cover.

I

F

G

H

J

Battery Symbols

(displayed in lower half of LCD screen)

F: Good Batteries

G: Weak Batteries

H: Failed Batteries

Lamp Symbols

I: Lamp Life Progress Bar (displayed between upper and lower LCD screens)

J: Lamp Failure (displayed in upper half of LCD screen)

LCD Symbols Operating and Battery Signals

(1 Liter example shown; see above for

1/2 Liter Volume Symbol)

1 Volume Selection and Dose Activation

With Good Batteries.

Volume selection visible in lower display.

Timer ring visible in upper display.

2 Volume Selection and Dose Activation

With Weak, but Functional Batteries

Volume selection alternates with Weak Battery symbol in lower display.

3 Volume Selection With Failed Batteries

Batteries too weak to start purification cycle; volume selection does not display; Failed

Batteries symbol flashes in lower display.

4

5

6

7

8

28

Purification Timer Progress (1/2 L dose shown)

For both 1/2 Liter and 1 Liter volumes, timer ring in upper display starts out empty and fills with black, in a clockwise direction, as dose time passes.

Dose Complete With Good Batteries

Smiling timer visible in upper display; volume selection and Good Battery symbol visible in lower display.

Dose Complete With Weak Batteries

Smiling timer visible in upper display; volume selection and Weak Battery symbol visible in lower display.

Dose Incomplete Due To Failed Batteries

If dose is ended prematurely due to battery failure, timer ring stops progressing. Dose Status: Failed symbol visible in upper display; Failed Batteries symbol visible in lower display.

Dose Incomplete

If sensor pins are removed from water before dose is completed, timer ring stops progressing.

Dose Status: Failed symbol flashes in upper display.

SteriPEN™ Journey LCD Display Symbols

A

B

C

D

E

Key to Symbols

Volume Selection

(displayed in lower half of LCD screen)

A: 1 Liter Volume Selected

B: 1/2 Liter Volume Selected

Timer Ring

(displayed in upper half of LCD screen)

C: Dose Time Progressing

D: Dose Status: Successful

E: Dose Status: Failed

9

10

11

12

Lamp Life Progress Bar

As doses are used, the lamp life bar fills in black from left to right reflecting the proportion of doses used verses unused (the unit is programmed for a

total of 10,000 doses). Lamp progress bar is not visible while lamp is on.

Lamp Approaching End of Life

When the microcontroller has recorded 9,900 lamp cycles, the Lamp Life Progress Bar will blink.

Broken Lamp

Lamp Failure symbol visible in upper display;

Lamp Life Progress Bar visible.

End of Lamp Life

Lamp Failure symbol visible in upper display;

Lamp Life Progress Bar filled with black.

Safety

SteriPEN™ Journey LCD may be used in glass, plastic, ceramic or metal containers. They all absorb and reflect UV light, thereby shielding the user from UV exposure. Journey LCD should not be used in quartz containers. The air/water interface at the top of any drinking container is highly reflective to UV and reflects UV back into the container.

Water Sense Circuitry

The Journey LCD water sense circuitry is intended to prevent the UV lamp from illuminating unless it is completely immersed in water. If Journey LCD is not immersed in water within 15 seconds of being activated, it will deactivate.

Agitation of Water

Agitation of the water by stirring with Journey LCD or rocking the container is essential for proper operation as this insures uniform exposure of all water to germicidal UV light.

Cold Weather Considerations

Bring SteriPEN™ Journey LCD up to a temperature above 32°F/0°C before using. Battery performance may be adversely affected by cold weather. NiMH rechargeable batteries are the best choice for economical use as well as for cold weather. Store your batteries in your pocket or warm place when in cold weather conditions.

Battery Selection & Installation

SteriPEN™ Journey LCD uses two CR123 batteries.

CR123 batteries are nominally 3 volts and are available in both rechargeable and non-rechargeable (disposable) varieties.

Our testing has shown that a single set of non-rechargeable (disposable) CR123’s will treat approximately 50 liters of water. Testing on rechargeable CR123’s indicates that approximately

35 liters may be treated between battery charges.

For best results, use high-quality batteries.

Cold ambient temperatures may reduce the number of doses available from batteries. To maximize available battery power keep your batteries in a warm place (i.e. your pocket) when in cold weather conditions. To replace batteries, loosen screw in battery end cap with a coin and then remove end cap (see “Operating the SteriPEN™, diagram 1). Install new or recharged batteries with battery polarity as shown. Replace the battery end cap and tighten screw until snug. Do not over-tighten screw

as this may damage the device. Note that if you will be storing your SteriPEN™ Journey LCD for a long period of time, it is best to remove the batteries from the device.

IMPORTANT NOTE: Many brands of CR123 batteries have built-in protection circuitry that instantly disables battery function when batteries reach a specific low charge threshold. If this “disable” function is triggered during operation the Journey LCD will be unable to display the Weak Batteries signal. Until batteries are replaced or recharged the Journey LCD will not be operational.

Treating Turbid, Murky or Cloudy Water

SteriPEN™ Journey LCD is intended for use, and is most effective, in clear water. However, Journey LCD has been shown to reduce microbial contamination in turbid water. If clear water is not available, first try to filter the water to clarify it. If it is necessary to treat turbid, murky or cloudy water in an emergency situation, use Journey LCD as follows:

• To treat 1 liter of turbid water, use two one-liter treatments. To accomplish this, push the operating button one time and complete the first treatment.

Then push the button one time again and complete the second treatment.

• To treat 0.5 liters of turbid water, use a single 1 liter dose. To accomplish this, push the operating button once and complete the treatment.

Turbidity is a measure of water clarity as affected by the presence of suspended solids. As turbidity increases, the suspended solids and murkiness of the water also increase. It is difficult to communicate a particular level of turbidity with just a written description. Accordingly, please take into account the following when considering the use of Journey LCD in water that is not clear: Laboratory testing has shown that Journey LCD is effective in water with a turbidity of not less than 30 ntu (Nephelometric Turbidity Units) as described in the US EPA Guide Standard and Protocol for Testing Microbiological

Water Purifiers, section 3.3.4. Journey LCD has been successfully tested in water with a turbidity measurement of 33 ntu. If viewing 33ntu water in a clear

1 liter bottle, one might characterize the water as follows: Much closer to clear than opaque, Obvi- ously not clear, Obviously cloudy, Objects viewed through the water are visible but blurry, As cloudy as weak lemonade.

Care and Cleaning

When not in use, SteriPEN™ Journey LCD should be kept in a clean, dry, non-abrasive area or container.

Journey LCD should not be exposed to ambient temperatures above 140°F/60°C or below -4°F/-20°C.

When storing Journey LCD for long periods, remove batteries.

To clean Journey LCD , wash with a soft cloth and a mild soap solution. Rinse soap from device and dry with a clean, soft cloth. Note that while the battery compartment of Journey LCD is designed to be water resistant, it is not guaranteed to be impermeable and should therefore never be submerged.

Troubleshooting

If the LCD screen indicates SteriPEN™ Journey LCD is ready, but the lamp does not light when immersed in water, check to be sure lamp is completely immersed and that water is contacting both sensors.

If immediately after completing a treatment another treatment is attempted, but LCD screen indicates incomplete dose (see LCD Symbol 8), check to see that the Journey LCD water sensors are not wet. Dry sensors and press On/Off button again.

If fresh batteries have been installed, but Journey LCD will not complete a dose, low temperature may be the cause. NiMH rechargeable batteries are a better choice for cold weather applications.

Repair Information

Any repairs to your SteriPEN™ Journey LCD should be done by an authorized technician. Please contact your local distributor/importer for all repairs.

Product Registration & Warranty Information

Limited Lifetime Warranty for any manufacturing defect. For product registration and complete warranty information, please visit www.steripen.com/warranty or contact your local distributor/importer.

Warnings for Safe Use

• Improper operation of SteriPEN™ Journey LCD may cause injury. Read and understand all warnings prior to operating Journey LCD .

• Do not allow water to enter Journey LCD through the battery compartment.

• Do not submerge the battery compartment end of the device.

• Do not operate Journey LCD in quartz containers such as quartz laboratory beakers.

• Journey LCD is not intended for use by children.

• Journey LCD is a high voltage device. Removal or tampering with the electronic circuit board or lamp assembly may cause injury, or damage Journey LCD .

• Do not open, expose, modify or touch internal circuitry; this can lead to high voltage shock.

• Do not attempt to bypass water sensor; this is an important safety feature.

• As with any water treatment system, you should always have a backup method available.

• Like most fluorescent-type lamps, The Journey LCD lamp contains a small amount of mercury. Please return your Journey LCD at the end of its productive life to your distributor/importer to permit correct recycling or safe disposal.

• Journey LCD is not intended to disinfect surfaces of a drinking container, i.e. those that typically contact the mouth when drinking. Be certain that your drinking container has been properly cleaned/washed prior to using Journey LCD .

• Journey LCD is not intended to disinfect water above the surface of the water in the container, i.e., droplets of water suspended on the side of the glass.

• Journey LCD is intended for use with clear water but in emergencies may be used in moderately turbid water.

See "Treating Turbid, Murky or Cloudy Water" section above before deciding to use Journey LCD on turbid water.

• Journey LCD is designed to treat 0.5 or 1.0 liter (16 or 32 fl. oz.) of clear water. If in doubt about volume of water to be treated, confirm volume with a measuring device such as a measuring cup.

• Do not store Journey LCD for long periods with alkaline batteries installed.

• When operating properly, the Journey LCD lamp will emit visible light as well as UV. If lamp is not emitting visible light, it is not functioning properly, and should not be used until repaired.

• The Journey LCD lamp assembly must be clean prior to use.

• If Journey LCD is below 32°F/0°C it should be warmed above 32°F/0°C before operating.

• Do not allow impact to the lamp end. If lamp assembly

(lamp or quartz sleeve) is cracked, chipped or damaged, do not operate. Return to your local distributor/importer for repair.

• Do not use as a light source.

• Do not use in liquids other than clear water.

• Do not use in water with ice.

• Do not use in water above 140°F/60°C.

• UV light can be harmful to eyes and skin. Never look at an unshielded UV lamp during operation. When used properly, according to instructions, the user is well shielded from Journey LCD UV light.

• Do not operate near skin.

• Do not operate near eyes.

• Do not insert into bodily orifices.

• While carefully controlled microbiological testing of Journey LCD has been conducted, use of Journey LCD in the field may produce results that vary from our laboratory test data.

• Do not use in any manner other than instructed in this

User’s Guide.

Certifications & Patents

Compliance testing of SteriPEN™ for the cETLus and CE marks was successfully completed at Intertek Testing Services (ITS), Boxborough, MA,

USA. This testing is described in ITS test report number: J20027896.01, October 18, 2000.

Conforms to EN61010-1:1993 + A1 + A2 and EN 61326

Listed 3058969. Conforms to Standard UL 61010A-1

Certified to CAN/CSA Standard C22.2, No. 1010.1-92

U.S.E.P.A. Company #73679, U.S. EPA Establishment

#07369-ME-001

SteriPEN™ technology is patented in the USA with further U.S. patents pending and patents pending worldwide. SteriPEN™ is a trademark of Hydro-Photon, Inc. U.S. Patent Numbers 5,900,212

& 6,110,424 & 6,579,495

SteriPEN™ Journey

LCD

works with the

SteriPEN™ Pre-Filter

(sold separately).

Fits most wide-mouth water bottles.

1) Fill Bottle

2) Purify

Guide to SteriPEN™ Journey LCD Parts

1) UV Lamp Cover

2) UV Lamp Assembly

3) Water Sensors (2)

4) Rubberized Neck

5) On/Off Button

6) Thumb Grip (finger grips on opposite side of device)

7) Indicator LCD (Liquid Crystal Display):

Displays Operating, Battery, and Lamp Signals

8) Battery Compartment End Cap

9) Warning Label

3) Drink

Did you know?

Hydro-Photon, Inc.

P.O. Box 675

262 Ellsworth Rd.

Blue Hill, ME 04614 USA

Tel: (207) 374-5800

Fax: (207) 374-5100 [email protected]

www.steripen.com

MANJY0712

You can use your SteriPEN™ Journey

LCD

with pre-filled water bottles up to 1 liter in size.

Using Journey

LCD

instead of buying bottled water keeps plastic bottles out of landfills.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement