James Hardie 6711131 Plank Statement Collection 8.25 in. x 144 in. Fiber Cement Cedarmill Lap Siding Khaki Brown Product Manual
Реклама
Реклама
HardiePlank
®
Lap Siding Product Description
HardiePlank ® lap siding is factory-primed fiber-cement lap siding available in a variety of styles and textures. Please see your local James Hardie ® product dealer for product availability. HardiePlank lap siding comes in 12 ft. lengths.
Nominal widths from 51/4 in to 12 in. create a range of exposures from 4 in to 103/4 in
HardiePlank lap siding is also available with ColorPlus ® Technology as one of James Hardie’s prefinished products.
ColorPlus ® Technology is a factory applied, oven-baked finish available on a variety of James Hardie siding and trim products. See your local dealer for details and availability of products, colors, and accessories.
The HZ5 ® product line is right at home in climates with freezing temperatures, seasonal temperature variations, snow and ice. HZ5 ® boards are the result of our generational evolution of our time-tested products. We’ve evolved our substrate composition to be specifically designed to perform in conditions found in these climates. To ensure that its beauty matches its durability, we’ve engineered the surface for higher performance, giving it superior paint adhesion and moisture resistance. In addition, we’ve added a drip edge to the HardiePlank ® HZ5 ® lap siding product to provide improved water management in conditions specific to HZ5 ® climates.
Select Cedarmill © Smooth Beaded Cedarmill ©
Beaded Smooth
Drip Edge
Custom Colonial Roughsawn ® Custom Colonial Smooth ®
Sloped
Edge
Nail Line
85
Appendix/ Glossary
ESR-1844 & 2290 Report
Finishing and Maintenance
Installation of HardiePlank
®
Lap Siding
INSTALL A STARTER STRIP
HardiePlank ® lap siding requires a starter strip beneath the first course to set it on the proper angle and to create a proper drip edge at the bottom of the siding. Starter strips are easily made by ripping 1¼ in. pieces of HardiePlank siding from full or partial planks.
The bottom of the starter strip should be installed even with the bottom of the mudsill or the bottom edge of the sheathing. The strip must be installed over the water-resistive barrier, but occasional gaps should be left in the starter strip to allow any accumulated moisture behind the siding to drain away safely.
10.1
Water-resistive barrier
Install starter strip over the weather barrier and even with the bottom of the sheathing.
Starter strip
OVERVIEW OF HARDIEPLANK LAP SIDING
TIP: For accurate fastening, snap vertical chalk lines on the water-resistive barrier at the center of every stud location.
10.2
Water-resistive barrier
Framed wall with structural sheathing
Ends of planks must land over a stud.
Starter strip builds out siding to the proper angle.
Joint flashing
Install factory ends of planks at butt joints.
Stagger butt joints a minimum of 2 stud bays for 16 in. O.C. framing
Framing square and torpedo level transfer the course elevations
86
INSTALLING THE PLANKS
10.3
The first course of HardiePlank ® siding is critical to the proper installation of the plank on the rest of the building. The first course should start at the lowest point of the house and within required clearances. Special attention should be made to ensure that it’s straight and level. Attention should also be paid to staggering any butt joints in the planks so that the installation is attractive while making efficient use of material.
6 in min
Keep bottom edge of the first course even with the bottom of the corner trim.
1. Use a level (4 ft. or longer) or chalked level line to be sure that the first course is level.
As installation proceeds up the wall, peri-
Use a level 4 ft. or longer level to check the first course.
Snapped chalk line guides the first course.
odically check the level and straightness of the courses. When correcting for flatness over products such as exterior insulation, use drywall shims. It is good practice to snap a chalk line every 3 to 5 courses to keep the planks straight and level.
2. Position the bottom edge of the first course of siding a minimum ¼ in below the edge of the starter strip (maintain required clearances) and secure.
3. Run the siding to the HardieTrim ® board leaving a 1/8 in. gap between the siding and trim.
The bottom of the siding should be kept even with the bottom of the trim, or if desired, the trim may extend below the bottom of the siding. But the siding should never hang below the trim. *When installing the first course make sure ground clearances are in accordance with James Hardie requirements and those of local codes.
PLANK ALIGNMENT AT CORNERS
10.4
For the best looking installation, make sure that the heights of the plank courses match on both sides of a corner. Use a framing square, speed square or a level to match up the plank heights. Check every few courses to make sure proper heights are being maintained.
HANDLING
IMPORTANT: To prevent damage to the drip edge, extra care should be taken when removing planks from the pallet, while handling, and when installing with a lap gauge. Planks are interlocked together on the pallet, therefore they should be removed from the pallet horizontally (side to side) to allow planks to unlock themselves from one another.
End plank courses 1 /
8
in from vertical trim and fill gap with permanently flexible caulk.
TIP: When taking planks from the pallet installation, avoid repeating the texture pattern by working across the pallet. Two to four planks can be removed from a stack at one time. But then material should be taken from adjacent stacks, again working across the pallet. Texture repeat is typically a concern on large walls with few breaks such as windows or doors.
87
Installation of HardiePlank
®
Lap Siding (cont.)
Finishing and Maintenance
Appendix/ Glossary
ESR-1844 & 2290 Report
BLIND NAILING (nailing through top of plank)
10.5
Blind nailing measurments
Blind nailing is recommended for installing any type of HardiePlank ® lap siding including ColorPlus ® siding. With blind nailing, each course covers the fasteners on the course below, which provides a better looking installation.
Nails for blind nailing shall be between 3/4 in and
1 in. from the top of the board.
For blind nailing HardiePlank lap siding,
James Hardie recommends driving fasteners 1 in. from the top edge of the plank. Additionally fasteners should be
Keep nails
3 /
8
in from ends of boards.
10.6
Blind nailing
Fasteners are hidden by the course above.
Nails are driven through the sheathing into the studs.
placed no closer than 3/8 in from the ends of the plank.
HardiePlank ® HZ5 ® Lap Siding is manufactured with a nail line that should be used as a guide for proper nail placement when blind nailing. This nail line should not be used as a lap line.
Avoid placing fasteners near the top edge of the plank. This practice, called “high nailing”, may lead to loose planks, unwanted gaps or rattling. Pin-backed corners may be done for aesthetic purposes only. Finish nails are recommended for pin-backs. Headed siding nails are allowed. Place pin-backs no closer than
1in. from plank ends & 3/4in. from plank edge into min. 3/8in. wood structural panel. Pin-backs are not a substitute for blind or face nailing
FACE NAILING (nailing through the overlap at the bottom of the plank)
10.7
Face nailing
Although blind nailing is recommended by James Hardie, face nailing may be required for certain. installations including: installations in high wind areas, fastening into OSB or equivalent sheathing without penetrating a stud, or when dictated by specific building codes. Refer to Appendix D for related code matters.
Exposed fasteners are driven through the face of the boards.
Drive fasteners only where planks overlap
STAGGERING THE BUTT JOINTS
For walls longer than 12 ft, it is necessary to butt joint additional lengths of HardiePlank siding. These butt joints should be staggered to avoid noticeable patterns, which is determined by the placement of the first course. Butt joints between consecutive courses should be spaced apart by at least two stud bays for 16 in, o.c. framing or one bay for 24 in. o.c. framing.
While random placement of the planks is usually the most aesthetically pleasing, a progressive stagger pattern can make the job easier and faster without the pattern becoming too noticeable.
With this strategy, the cut off piece for one course becomes the starter piece for a course above, making efficient use of materials and ensuring that all butt joints land on studs. The pattern can be modified for different stud placement.
88
10.8
Cutoff pieces form the starter pieces for courses above.
For walls longer than 12 ft land butt joints over studs, staggering the joints at least
24 in (for 24 in. o.c. framing) or 32 in. (two stud bays for
16 in. o.c. framing).
JOINT FLASHING
One or more of the following joint treatment options are required by code (as referenced 2009 IRC R703.10.2)
A. Joint Flashing (James Hardie recommended)
B. Caulking* (Caulking is not recommended for ColorPlus for aesthetic reasons as the Caulking and ColorPlus will weather differently. For the same reason, do not caulk nail heads on ColorPlus products.}
C. “H” jointer cover
10.9
Flashing behind butt joints provides an extra level of protection against the entry of water at the joint. James Hardie recommends 6 in. wide flashing that overlaps the course below by 1 in. Some local building codes may require different size flashing.
Joint-flashing material must be durable, waterproof materials that do not react with cement products. Examples of suitable material include finished coil stock and
10.10
code compliant water-resistive barriers. Other products may also be suitable.
Flashing behind to add an additional layer of protection from water infiltration
Extend flashing
1 in. onto the course below
TIP: Joint flashing can be quickly and easily made by cutting a 6 in. wide section off a roll of housewrap. Tape the roll tightly at the cut mark and cut the section off using a miter saw with a carbide blade. Individual sheets then can be cut to length with a utility knife.
TIP: Use light-colored joint flashing when using light-colored ColorPlus lap siding or other siding with a light-colored finish. Dark-color joint flashings should be used on siding with dark finishes.
Caulking at HardiePlank lap siding butt joints is not recommended for ColorPlus for aesthetic reasons as the caulking and
ColorPlus will weather differently. For the same reason, do not caulk exposed nail heads. Refer to the ColorPlus touch-up section for details
JOINT PLACEMENT AND TREATMENT
Butt joints in HardiePlank lap siding should always land on a stud. Butt joints between studs are not recommended and should be avoided. Whenever possible, factoryfinished ends should be used at butt joints.
10.11
Place cut ends where the siding meets a corner, door, window trim, or other break in the wall where the joint is to be caulked. If cut ends are used in a butt joint between planks, James Hardie requires sealing cut ends for all products. For ColorPlus products, use the color-matched edge coater to seal the cut end.
Butt planks with moderate edge contact
COLORPLUS ® TIP: When installing HardiePlank lap siding with ColorPlus
Technology, position the plank in the immediate area where the plank is to be fastened.
Do not place the plank on the course below and slide into position. Doing so may scuff or scratch the ColorPlus finish on the installed piece.
89
Installation of HardiePlank
®
Lap Siding (cont.)
Finishing and Maintenance
Appendix/ Glossary
ESR-1844 & 2290 Report
CONTINUING THE INSTALLATION
10.12
Planking around windows
Once the initial course of HardiePlank ® siding is fastened to the wall, continue installing successive courses with full
12 ft. pieces (follow the stagger pattern for longer walls), or until a window, door or other opening interrupts the course
(fig 10.12). Notch planks as needed to fit around windows and doors. Again, be sure to seal all cut edges. Avoid placing butt joints directly above or below windows or above doors. Separate the joint from the opening by at least one course of siding.
Add an extra stud if necessary for nailing the ends of the planks.
Notch plank around window trim and flashing.
Keep butt joints more than one course away from top of window.
Where butt joints land on a stud, make sure there is enough stud space for plank on both sides of the joint to land properly.
Optimally both sides of a butt joint should land in the middle of a stud with
3/4 in landing space for each side. The minimum stud space for a plank to land is 3/8 in
Pay special attention to window, doors, and corners that have been trimmed before the siding goes on.
Vertical trim boards may cover the king studs beside windows or doors, or they may cover up corner studs leaving no room for nailing the siding. In these places add extra studs as needed.
COLORPLUS TIP: HardiePlank lap siding with ColorPlus Technology is shipped with a protective laminate slip sheet, which should be left in place during cutting and fastening to reduce marring and scratching. The sheet should be removed immediately after each plank is installed.
If corners are trimmed with HardieTrim ® 5/4, 4/4 boards, it may be necessary to measure and cut the first pieces of siding to make sure the butt joints land on studs.
INSTALLING HARDIEPLANK
®
SIDING ON GABLE WALLS
Siding gable walls can be challenging, and some of the keys to siding gable walls efficiently are determining the angle or pitch of the roof, properly staging materials, and ensuring that the plank lengths are measured accurately.
To estimate the amount of siding needed to complete a gable end, use the estimating tools located in Appendix C.
Stage enough material on the pump jacks or scaffolding to complete the gable end, but take care not to overload the staging. When possible, a cut table should be located on the pump jacks or scaffolding, which frees up crew members to work on other walls.
90
To cut planks for the gable:
1. Tack up a small scrap piece of siding where the first gable course is going.
2. Hold a second small piece of siding against the eave or rake board.
3. Trace the angle onto the scrap.
10.13
4 Draw the angle, cut and repeat the process for the next course.
Tip for fast gable installation
4. Cut that line and label the scrap as the template for the gable angle. The template can then be used to transfer the angle onto the larger pieces for cutting and installation.
5. Periodically check the angle as you progress up the wall.
10.14
Angle Template
Scrap piece of siding held against rake board
The quickest way to measure and cut consecutive courses of siding for a gable is to work off the previous piece. Scrap piece of siding
1. Cut and fit the lowest course of siding.
2. Before installing, lay it flat and measure down 1¼ in. from the top edge of the plank for the course overlap. Make a mark on both ends.
3. Set a piece of uncut siding on top of the first piece, aligning the bottom edge with the overlap marks. Transfer the length directly to the uncut piece.
HARDIEPLANK
®
SIDING FASTENER SPECIFICATIONS
The Fastener Specifications table shows fastener options for a variety of different nailing substrates. Please refer to the applicable ESR report online (see back page) to determine which fastener meets your wind load design criteria.
Fastener
Substrate wood studs
16 in o.c.
24 in o.c.
16 in o.c.
Approved
Fastener
2
3
16
9
5
Draw line here
2
.113 in x .267 in x 2 in
3
.093 in x .222 in. x 2 in
9
3 Place a plank for the next piece on the overlap lines and mark the length.
2 Before installing, measure down the 1 1 /
4
in. overlap at the top of the board.
1 Measure, cut and fit lowest gable plank using gable angle template.
Fastener Type
No 11ga 1.25 in long
6D common
6D siding nail roofing nail
4. Draw the gable angle with the template, cut the angle and then repeat the process for the next course.
TIP: Stainless steel fasteners are recommended when installing James Hardie ® products.
steel
studs *
24 in o.c.
16 in o.c.
24 in o.c.
16 in o.c.
2
8
5
13
7
Ribbed Bugle-Head No. 8
.323 in x 1.625 in screws
8
Ribbed Wafer-Head No. 8 (.375 in x 1.25 in)
12
[AKN-100] .100 in x .25 in x 1.5 in
ET&F
13
[AGS-100] .100 in x .313 in x 1.5 in
24 in o.c.
7 12
14 masonry nail
[ASTM C-90] ASM-144-125 (P/C)
.30 in x .14 in x 1.25 in
5
.113 in x .260 in x 2.375 in
8D common
14
Direct to Masonry
7/16 in OSB or equivalent (face nailed)
4
16
No 11ga 1.75 in long roofing nail
4
.091 in. x .221 in. x 1.5 in
4D siding nail
* When blind fastening 9.5 in or wider
product onto steel studs, use screws.
indicates recommended fasteners
91
Hardie Plank
®
Lap Siding
Note: Field painting over caulking may produce a sheen difference when compared to the field painted PrimePlus. *Refer to Caulking section in these instructions.
¹For additional information on HardieWrap® Weather Barrier, consult James Hardie at 1-866-4Hardie or www.hardiewrap.com
SELECT CEDARMILL © | SMOOTH | BEADED CEDARMILL © | BEADED SMOOTH
Visit jameshardiepros.com for the most recent version.
92
EFFECTIVE SEPTEMBER 2019
IMPORTANT: FAILURE TO FOLLOW JAMES HARDIE WRITTEN INSTALLATION INSTRUCTIONS AND COMPLY WITH APPLICABLE BUILDING CODES MAY VIOLATE LOCAL LAWS, AFFECT
BUILDING ENVELOPE PERFORMANCE AND MAY AFFECT WARRANTY COVERAGE. FAILURE TO COMPLY WITH ALL HEALTH AND SAFETY REGULATIONS WHEN CUTTING AND INSTALLING
THIS PRODUCT MAY RESULT IN PERSONAL INJURY. BEFORE INSTALLATION, CONFIRM YOU ARE USING THE CORRECT HARDIEZONE® PRODUCT INSTRUCTIONS BY VISITING
HARDIEZONE.COM OR CALL 1-866-942-7343 (866-9-HARDIE)
STORAGE & HANDLING:
Store flat and keep dry and covered prior to installation. Installing siding wet or saturated may result in shrinkage at butt joints. Carry planks on edge. Protect edges and corners from breakage.
James Hardie is not responsible for damage caused by improper storage and handling of the product.
CUTTING INSTRUCTIONS
OUTDOORS
1. Position cutting station so that airflow blows dust away from the
user and others near the cutting area.
2. Cut using one of the following methods:
a. Best: Circular saw equipped with a HardieBlade ® saw blade
and attached vacuum dust collection system. Shears
(manual, pneumatic or electric) may also be used, not
recommended for products thicker than 7/16 in.
b. Better: Circular saw equipped with a dust collection feature
(e.g. Roan ® saw) and a HardieBlade saw blade.
c. Good: Circular saw equipped with a HardieBlade saw blade.
INDOORS
DO NOT grind or cut with a power saw indoors. Cut using shears (manual, pneumatic or electric) or the score and snap method, not recommended for products thicker than 7/16 in.
- DO NOT dry sweep dust; use wet dust suppression or vacuum to collect dust.
- For maximum dust reduction, James Hardie recommends using the “Best” cutting
practices. Always follow the equipment manufacturer’s instructions for proper operation.
- For best performance when cutting with a circular saw, James Hardie recommends
using HardieBlade ® saw blades.
- Go to jameshardiepros.com for additional cutting and dust control recommendations.
IMPORTANT: The Occupational Safety and Health Administration (OSHA) regulates workplace exposure to silica dust. For construction sites, OSHA has deemed that cutting fiber cement with a circular saw having a blade diameter less than 8 inches and connected to a commercially available dust collection system per manufacturer’s instructions results in exposures below the OSHA Permissible Exposure Limit (PEL) for respirable crystalline silica, without the need for additional respiratory protection.
If you are unsure about how to comply with OSHA silica dust regulations, consult a qualified industrial hygienist or safety professional, or contact your James
Hardie technical sales representative for assistance. James Hardie makes no representation or warranty that adopting a particular cutting practice will assure your compliance with OSHA rules or other applicable laws and safety requirements.
IMPORTANT: To prevent damage to the drip edge, extra care should be taken when removing planks from the pallet, while handling, and when installing with a lap gauge. Please see additional handling requirements on page 4.
GENERAL REQUIREMENTS:
• HardiePlank ® lap siding can be installed over braced wood or steel studs, 20 gauge (33 mils) minimum to 16 gauge (54 mils) maximum, spaced a maximum of 24 in o.c. or directly to minimum 7/16 in thick OSB sheathing. See General Fastening Requirements. Irregularities in framing and sheathing can mirror through the finished application. Correct irregularities before installing siding.
• Information on installing James Hardie products over non-nailable substrates (ex: gypsum, foam,etc.) can be located in JH Tech Bulletin 19 at www.jamehardie.com
• A water-resistive barrier is required in accordance with local building code requirements. The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture HardieWrap ® Weather Barrier, a non-woven non-perforated housewrap¹, which complies with building code requirements.
• Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum of 6 in. in the first 10 ft..
• Do not use HardiePlank lap siding in Fascia or Trim applications.
• Do not install James Hardie products, such that they may remain in contact with standing water.
• HardiePlank lap siding may be installed on flat vertical wall applications only.
• For larger projects, including commercial and multi-family projects, where the span of the wall is significant in length, the designer and/or architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin “Expansion Characteristics of James Hardie ® Siding Products” at www.jameshardie.com.
• James Hardie Building Products provides installation /wind load information for buildings with a maximum mean roof height of 85 feet. For information on installations above 60 feet, please contact JH technical support.
Double Wall
Construction water-resistive barrier plywood or
OSB sheathing
Figure 1
Single Wall
Construction let-in bracing
24 in. o.c. max.
stud
Figure 2
INSTALLATION:
JOINT TREATMENT
One or more of the following joint treatment options are required by code (as referenced 2009 IRC R703.10.2)
A. Joint Flashing (James Hardie recommended)
B. Caulking* (Caulking is not recommended for ColorPlus for aesthetic reasons as the
Caulking and ColorPlus will weather differently.
For the same reason, do not caulk nail heads on
ColorPlus products.)
C. “H” jointer cover waterbarrier
Nail line (If nail line is not present, place fastener between 3/4 in. & 1 in. from top of plank)
Nail 3/8 in. from edge of plank
Install planks in moderate contact at butt joints
Leave appropriate gap between planks and trim, then caulk.* fastener water-resistive barrier
Install a 1 1/4 in. starter strip to ensure a consistent plank angle
HS11117 P1/4 09/19
Hardie Plank ® Lap Siding
CLEARANCE AND FLASHING REQUIREMENTS
Figure 3
Roof to Wall
Figure 4
Horizontal Flashing
Z-Flashing
Min. 2 in.
Min. ¼ in.
Do not caulk
Figure 5
Kickout Flashing
As required by IRC code min 4 in. x 4 in.
Figure 6
Slabs, Path, Steps to Siding
Min. 2 in.
Figure 7
Deck to Wall
Z-Flashing
Figure 8
Ground to Siding
Figure 9
Gutter to Siding
Figure 10
Sheltered Areas
Z-Flashing
Figure 11
Mortar/Masonry
L-Flashing
Z-Flashing
Min.
2 in.
Min. ¼ in.
Figure 12
Drip Edge
6 in.
1in.
Figure 13
Block Penetration
Z-Flashing
Min. ½ in.
Figure 14
Valley/Shingle Extension
Extend shingles at least 1 in. out from the fascia when gutters are present
Min. ¼ in.
FASTENER REQUIREMENTS*
Refer to the applicable ESR report online to determine which fastener meets your wind load design criteria.
Blind Nailing is the preferred method of installation for HardiePlank ® lap siding products. Face nailing should only be used where required by code for high wind areas and must not be used in conjunction with Blind nailing (Please see JH Tech bulletin 17 for exemption when doing a repair).
BLIND NAILING
Nails - Wood Framing
• Siding nail (0.09 in. shank x 0.221 in. HD x 2 in. long)
• 11ga. roofing nail (0.121 in. shank x 0.371 in. HD x 1.25 in. long)
FACE NAILING
Nails - Wood Framing
• 6d (0.113 in. shank x 0.267 in. HD x 2 in. long)
• Siding nail (0.09” shank x 0.221” HD x 2” long)
Screws - Steel Framing
• Ribbed Wafer-head or equivalent (No. 8 x 1 1/4 in. long
x 0.375 in. HD) Screws must penetrate 3 threads into metal framing.
Nails - Steel Framing
• ET & F Panelfast ® nails or equivalent (0.10 in. shank x 0.313 in. HD x 1-1/2 in. long)
Nails must penetrate minimum 1/4 in. into metal framing.
OSB minimum 7/16 in.
• Siding nail (0.09 in. shank x 0.215 in. HD x 1-1/2 in. long
• Ribbed Wafer-head or equivalent (No. 8 x 1 5/8 in. long x 0.375 in. HD).
Screws - Steel Framing
• Ribbed Bugle-head or equivalent (No. 8-18 x 1-5/8 in. long x
0.323 in. HD) Screws must penetrate 3 threads into metal framing.
Nails - Steel Framing
• ET & F pin or equivalent (0.10 in. shank x 0.25 in. HD x 1-1/2 in. long)
Nails must penetrate minimum 1/4 in. into metal framing.
OSB minimum 7/16 in.
• Siding nail (0.09 in. shank x 0.221 in. HD x 1-1/2 in. long)
*Also see General Fastening Requirements; and when considering alternative fastening options refer to James Hardie's Technical Bulletin USTB 5 - Fastening Tips for HardiePlank Lap Siding.
HS11117 P2/4 09/19
93
Hardie Plank ® Lap Siding
FASTENER REQUIREMENTS continued
Stud
Nail Line
Blind Nail
Figure 14 Figure 15
Minimum overlap for Both Face and Blind Nailing
Joint
Flashing
Stud
3/4”-1” min. 1 1/4 in.
overlap
24”
O.C. max
Face Nail
1 1/4” min.
Overlap
1 1/4” min.
Overlap
Water Resistive
Barrier
Water Resistive
Barrier
Laminate sheet to be removed immediately after installation of each course for ColorPlus ® products.
Pin-backed corners may be done for aesthetic purposes only. Finish nails are recommended for pin-backs. Headed siding nails are allowed. Place pin-backs no closer than 1 in. from plank ends and 3/4 in. from plank edge into min. 3/8 in. wood structural panel. Pin-backs are not a substitute for blind or face nailing.
GENERAL FASTENING REQUIREMENTS
Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot-dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie ® products near the ocean, large bodies of water, or in very humid climates.
Manufacturers of ACQ and CA preservative-treated wood recommend spacer materials or other physical barriers to prevent direct contact of ACQ or CA preservative-treated wood and aluminum products. Fasteners used to attach HardieTrim Tabs to preservative-treated wood shall be of hot dipped zinc-coated galvanized steel or stainless steel and in accordance to 2009 IRC R317.3 or 2009 IBC 2304.9.5
PNEUMATIC FASTENING
James Hardie products can be hand nailed or fastened with a pneumatic tool.
Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. This will help control the
SNUG FLUSH depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with a smooth faced hammer - Does not apply for installation to steel framing).
DO NOT DO NOT DO NOT USE
• Consult applicable product evaluation or listing for correct fasteners type and placement to achieve specified design wind loads.
• NOTE: Published wind loads may not be applicable to all areas where Local Building
Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable compliance documentation.
• Drive fasteners perpendicular to siding and framing.
• Fastener heads should fit snug against siding (no air space).
• NOTE: Whenever a structural member is present, HardiePlank should be fastened with even spacing to the structural member. The tables allowing direct to OSB or plywood should only be used when traditional framing is not available.
CUT EDGE TREATMENT
Caulk, paint or prime all field cut edges. James Hardie touch-up kits are required to touch-up ColorPlus products.
CAULKING
For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS,
Class 25 or higher or a Latex Joint Sealant complying with ASTM C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer’s written instructions.
Note: some caulking manufacturers do not allow "tooling".
WOOD
FRAME
UNDER
DRIVE
IF, THEN
HAMMER
FLUSH
STEEL
FRAME
REMOVE &
REPLACE
OVER
DRIVE
IF, THEN ADDITIONAL NAIL
FACE
NAIL
SLANT
COUNTERSINK
& FILL
AL
ALUMINUM
FASTENERS
CLIPPED
HEAD NAILS
STAPLES
PAINTING
DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie ® products. Factory-primed James Hardie products must be painted within 180 days of installation.
100% acrylic topcoats are recommended. Do not paint when wet. For application rates refer to paint manufacturers specifications. Back-rolling is recommended if the siding is sprayed.
94 HS11117 P3/4 09/19
Hardie Plank ® Lap Siding
COLORPLUS
®
TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE
• Care should be taken when handling and cutting James Hardie ColorPlus ® products. During installation use a wet soft cloth or soft brush to gently wipe off any
residue or construction dust left on the product, then rinse with a garden hose.
• Touch up nicks, scrapes and nail heads using the ColorPlus ® Technology touch-up applicator. Touch-up should be used sparingly.
If large areas require touch-up, replace the damaged area with new HardiePlank ® lap siding with ColorPlus ® Technology.
• Laminate sheet must be removed immediately after installation of each course.
• Terminate non-factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus ® product dealer.
• Treat all other non-factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer.
Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products.
Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up will not be covered under the James Hardie ColorPlus Limited Finish Warranty.
COVERAGE CHART/ESTIMATING GUIDE
Number of 12 ft. planks, does not include waste
HARDIEPLANK ® LAP SIDING WIDTH
13
14
15
16
9
10
11
12
17
18
19
20
7
8
5
6
3
4
1
2
SQ
(1 SQ = 100 sq.ft.)
150
175
200
225
250
275
300
325
5 1/4
4
25
50
75
100
125
350
375
400
425
450
475
500
120
140
160
180
200
220
240
260
6 1/4
5
20
40
60
80
100
280
300
320
340
360
380
400
100
117
133
150
167
183
200
217
7 1/4
6
17
33
50
67
83
233
250
267
283
300
317
333
7 1/2
6 1/4
144
160
176
192
208
224
240
256
80
96
112
128
16
32
48
64
272
288
304
320
8
6 3/4
133
148
163
178
193
207
222
237
74
89
104
119
15
30
44
59
252
267
281
296
86
100
114
129
143
157
171
186
8 1/4
7
14
29
43
57
71
200
214
229
243
257
271
286
75
88
100
113
125
138
150
163
9 1/4
8
13
25
38
50
63
175
188
200
213
225
238
250
9 1/2
8 1/4
113
125
138
150
163
175
188
200
63
75
88
100
13
25
38
50
213
225
238
250
12
10 3/4
84
93
102
112
121
130
140
149
158
167
177
186
47
56
65
74
9
19
28
37
This coverage chart is meant as a guide. Actual usage is subject to variables such as building design.
James Hardie does not assume responsibility for over or under ordering of product.
Pull from across the stack
ADDITIONAL HANDLING REQUIREMENTS
IMPORTANT: To prevent damage to the drip edge, extra care should be taken when removing planks from the pallet, while handling, and when installing with a lap gauge. Planks are interlocked together on the pallet, therefore they should be removed from the pallet horizontally (side to side) to allow planks to unlock themselves from one another.
PAINTING JAMES HARDIE
®
SIDING
AND TRIM PRODUCTS WITH
COLORPLUS
®
TECHNOLOGY
When repainting ColorPlus products, James
Hardie recommends the following regarding surface preparation and topcoat application:
• Ensure the surface is clean, dry, and free of any dust, dirt, or mildew
• Repriming is normally not necessary
• 100% acrylic topcoats are recommended
• DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie ® Products.
• Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature
• DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section
Do not go down the stack
HS11117 P4/4 09/19
DANGER: May cause cancer if dust from product is inhaled. Causes damage to lungs and respiratory system through prolonged or repeated inhalation of dust from product. Refer to the current product Safety Data Sheet before use.
The hazard associated with fiber cement arises from crystalline silica present in the dust generated by activities such as cutting, machining, drilling, routing, sawing, crushing, or otherwise abrading fiber cement, and when cleaning up, disposing of or moving the dust. When doing any of these activities in a manner that generates dust you must (1) comply with the OSHA standard for silica dust and/or other applicable law, (2) follow James Hardie cutting instructions to reduce or limit the release of dust; (3) warn others in the area to avoid breathing the dust; (4) when using mechanical saw or high speed cutting tools, work outdoors and use dust collection equipment; and (5) if no other dust controls are available, wear a dust mask or respirator that meets NIOSH requirements (e.g. N-95 dust mask). During clean-up, use a well maintained vacuum and filter appropriate for capturing fine (respirable) dust or use wet clean-up methods - never dry sweep.
WARNING: This product can expose you to chemicals including respirable crystalline silica, which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
RECOGNITION: In accordance with ICC-ES Evaluation Report ESR-2290, HardiePlank® lap siding is recognized as a suitable alternate to that specified in the 2006, 2009, 2012 & 2015 International Residential Code for One and Two-Family
Dwellings, and the 2006, 2009, 2012 & 2015 International Building Code. HardiePlank lap siding is also recognized for application in the following: City of Los Angeles Research Report No. 24862, State of Florida Product Approval FL#13192,
Miami-Dade County Florida NOA No. 17-0406.06, U.S. Dept. of HUD Materials Release 1263f, Texas Department of Insurance Product Evaluation EC-23, City of New York MEA 223-93-M, and California DSA PA-019. These documents should also be consulted for additional information concerning the suitability of this product for specific applications.
© 2019 James Hardie Building Products, Inc. All rights reserved TM, SM and ® denote trademarks or registered trademarks of James Hardie Technology Limited.
Product warranties, safety information and additional installation
Изтегляне
Реклама