4Sight Ophthalmic
Diagnostic Unit
Quick Reference Guide
REV - B
INDEX
A-Scan .......................................................................................................................................................................3
How To Measure A New Patient ..........................................................................................................................................................3
B-Scan .......................................................................................................................................................................4
How To Measure A New Patient ..........................................................................................................................................................4
UBM ............................................................................................................................................................................6
How To Measure A New Patient ..........................................................................................................................................................6
Pachymeter .............................................................................................................................................................. 8
How To Measure A New Patient ..........................................................................................................................................................8
2 | To order in the U.S. and Canada call (800) 979.2020 • (610) 889.0200 International • +31 (0) 485.350300 Europe or visit www.accutome.com
Quick Reference Guide
A-SCAN
How To Measure A New Patient
1.
Step One: Begin a new patient, by selecting New
Patient .
2.
Step Two: Type the patient data into the appropriate fields.
3.
Step Three: Launch A-Scan Mode by clicking the
A-Scan icon .
4.
Step Four: On the measurement screen, choose your measurement options ( Eye Type, Contact/
Immersion, and OD/OS ); options can be adjusted by clicking on the associated icon.
5.
Step Five: Prepare by following the immersion shell/ probe setup guidelines.
6.
Step Six: When in auto mode, begin with foot pedal pressed.
7.
Step Seven: Pin back patient’s lids and place shell directly over the cornea. Fill shell with BSS past probe tip until waveforms are displayed on screen.
8.
Step Eight: Release foot pedal when spikes are acceptable and machine will auto-capture (if automatic capture mode is selected).
9.
Step Nine: Ensure all wave forms are within 0.1mm
(immersion) and 0.2mm (contact) and that the spikes are of sufficient amplitude and exhibit proper pattern.
You can check through the five scans by tapping the foot pedal. If you would like to replace a measurement, press and hold the foot pedal until scan is deleted, or press the Insert key on the PC.
After scan is deleted, a live waveform pattern will be on the screen. When spikes are acceptable, release the foot pedal to capture.
To order in the U.S. and Canada call (800) 979.2020 • (610) 889.0200 International • +31 (0) 485.350300 Europe or visit www.accutome.com
| 3
10.
Step Ten: When all five measurements are captured, switch to the fellow eye and repeat steps 4 to 9.
12.
Step Twelve:
Save icon
Save the patient info buy clicking the
at the bottom of the screen.
11.
Step Eleven: Compare Axial lengths of each eye
(difference should be no more than 0.3mm unless clinical history suggests otherwise.)
For assistance with navigating the device or any other questions, please feel free to contact Accutome
Diagnostic Support at [email protected] or
610.889.0200.
B-SCAN
How To Measure A New Patient
1.
Step One: Begin a new patient, by selecting New
Patient .
2.
Step Two: Type the patient data into the appropriate fields.
3.
Step Three: Select the appropriate Scan Group and
Protocol .
4.
Step Four: Launch B-Scan Mode by clicking the
B-Scan icon .
5.
Step Five: Press the button on the probe or use the foot pedal to activate probe and start video loop.
6.
Step Six: Ensure image/pathology is centered on the screen for several moments before stopping the video loop by pressing the button or foot pedal .
4 | To order in the U.S. and Canada call (800) 979.2020 • (610) 889.0200 International • +31 (0) 485.350300 Europe or visit www.accutome.com
Quick Reference Guide
7.
Step Seven: Select desired video loop under All
Views and use the play/pause buttons at bottom of screen to review and find desired frame.
8.
Step Eight: Once desired image is paused on the screen, use the image editing tools (optional) and click on the Snap Shot icon to save a digital image.
9.
Step Nine: Once all Snap Shots are taken, select the
Report icon .
10.
Step Ten: Under Report , your snapshots will be viewable. Hold the Ctrl or Shift key down and select the snapshots that are desired to be placed into the report. Selecting Preview will bring up the report page as it will look with the selected snapshots.
11.
Step Eleven: After previewing desired report, back out of preview and select Save to save current report.
NOTE:
• You can also select Review to bring up a list of all other reports saved for selected patient.
• Print will send the current report to printer.
• Export to DICOM will send the selected report to the previously setup DICOM location (see Manual).
For assistance with navigating the device or any other questions, please feel free to contact Accutome Diagnostic
Support at [email protected] or 610.889.0200.
To order in the U.S. and Canada call (800) 979.2020 • (610) 889.0200 International • +31 (0) 485.350300 Europe or visit www.accutome.com
| 5
UBM
How To Measure A New Patient
1.
Step One: Begin a new patient, by selecting New
Patient .
2.
Step Two: Type the patient data into the appropriate fields.
3.
Step Three: Select the appropriate Scan Group and
Protocol .
4.
Step Four: Launch UBM Mode by clicking the UBM icon .
5.
Step Five: Setup probe for appropriate measurement technique. (Clear Scan or Scleral
Shells)
6.
Step Six: Press the foot pedal button on the probe or use the
to activate probe and start video loop.
7.
Step Seven: Ensure image/pathology is centered on the screen for several moments before stopping the video loop by pressing the button or foot pedal .
8.
Step Eight: Select desired video loop under All
Views and use the play/pause buttons at bottom of screen to review and find desired frame.
6 | To order in the U.S. and Canada call (800) 979.2020 • (610) 889.0200 International • +31 (0) 485.350300 Europe or visit www.accutome.com
Quick Reference Guide
9.
Step Nine: Once desired image is paused on the screen, use the image editing tools (optional) and click on the Snap Shot icon to save a digital image.
10.
Step Ten: Once all Snap Shots are taken, select the
Report icon .
11.
Step Eleven: Under Report , your snapshots will be viewable. Hold the Ctrl or Shift key down and select the snapshots that are desired to be placed into the report. Selecting Preview will bring up the report page as it will look with the selected snapshots.
12.
Step Twelve: After previewing desired report, back out of preview and select Save to save current report.
NOTE:
• You can also select Review to bring up a list of all other reports saved for selected patient.
• Print will send the current report to printer.
• Export to DICOM will send the selected report to the previously setup DICOM location (see Manual).
For assistance with navigating the device or any other questions, please feel free to contact Accutome Diagnostic
Support at [email protected] or 610.889.0200.
To order in the U.S. and Canada call (800) 979.2020 • (610) 889.0200 International • +31 (0) 485.350300 Europe or visit www.accutome.com
| 7
PACHYMETER
How To Measure A New Patient
1.
Step One: Begin a new patient, by selecting New
Patient .
2.
Step Two: Type the patient data into the appropriate fields.
3.
Step Three: Launch B-Scan Mode by clicking the
Pachymeter icon .
4.
Step Four: On the measurement screen, choose the eye ( OD/OS ) and then choose the scan location on the cornea.
5.
Step Five: Begin measurement by clicking the Start
Reading icon .
6.
Step Six: Place probe on the eye in the location selected on the screen. The flat portion of the probe tip should be completely in contact perpendicular with the patient’s cornea (not at an angle).
Measurements will not be obtained unless the probe is in complete contact with the cornea.
8 | To order in the U.S. and Canada call (800) 979.2020 • (610) 889.0200 International • +31 (0) 485.350300 Europe or visit www.accutome.com
Quick Reference Guide
7.
Step Seven: Once you have captured 9 measurements, you may review those measurements for that corneal location in the chart on the right of the screen.
8.
Step Eight: Another location for the eye can be selected and measured, or switch eyes and repeat measurement steps.
9.
Step Nine: Save the patient info buy clicking the
Save icon at the bottom of the screen.
10.
Step Ten: After Save , select the Report icon .
Selecting this icon will generate a Pachymetry
Report.
For assistance with navigating the device or any other questions, please feel free to contact Accutome Diagnostic
Support at [email protected] or 610.889.0200.
To order in the U.S. and Canada call (800) 979.2020 • (610) 889.0200 International • +31 (0) 485.350300 Europe or visit www.accutome.com
| 9
1-800-979-2020 • 610-889-0200 • FAX 610-889-3233 • [email protected] • www.accutome.com
Total Solutions Provider for all of your ophthalmic needs.
ACCUTOME SURGICAL
Diamond Knives, Steel Knives, Sutures and Handheld
Surgical Instruments.
ACCUTOME CLINICAL
Office Medications and Supplies.
ACCUTOME DIAGNOSTIC
A-Scans, B-Scans, Pachymeters, Tonometer and UBM.
ACCUTOME REPAIR CENTER
• Quick turnaround for most brands of Diamond
Knives and Handheld Instruments.
• Diagnostic Equipment.
ORDERING
Call toll free (800) 979.2020 US and Canada
(610) 889.0200 International
+31 (0) 485.350300 Europe
Monday thru Friday 8:30AM - 8PM EST
Fax: (610) 889.3233
Email: [email protected]
Web: www.accutome.com
SHIPPING
Ground - Via UPS Ground Service
Air - Via best method
Saturday - Orders must be placed before 3PM EST
Friday to ensure Saturday delivery.
Payment should be made by check, Bank Transfer, Visa,
MasterCard or American Express.
CONTACT US
WATCH RESOURCES youtube.com/c/accutome
LIKE US facebook.com/pages/Accutome-Inc
TWEET US twitter.com/accutome
GOOGLE+ plus.google.com/+Accutome/
FOLLOW US linkedin.com/company/accutome-inc.
Distributed by:
10 | To order in the U.S. and Canada call (800) 979.2020 • (610) 889.0200 International • +31 (0) 485.350300 Europe or visit www.accutome.com