Thermo HS, HS ... /85, HSP, HSPC Safety Cabinet Operating instructions
PDF
Dokument
Oglas
Oglas
6. OPERATION UV disinfection mode one based on aldehyde, e.g., Barrycidal 36 [Interchem Set up the UV irradiator in the test chamber and connect it. Close the front window Switch State UV Switch (keyswitch) = close front window & DOWN button: As soon as the front window is lowered, an acoustic alarm will indicate hazards associated with lowering the window. The red indicator light shows that the window is not in its proper position. In the window's home position, the red indicator light also shows that there are now problems with the ventilation. The irradiator cannot be turned on until the front window is completely closed. Turn on the UV mode. U V Power switch (keyswitch) = UV: The safety glass traps all harmful UV light. The yellow indicator light and the bluish radiation indicate that the irradiator is operating. Products, Hermann Schulthess, Via dei Paoli 25, CH-6348 Minusio (German sales: Handelsvertretung Helmut Schröder, GauÃstraÃe 30/2, 70193 Stuttgart)]. When using alcohol-based disinfectants, please note: avoid EXPLOSION HAZARDS caused by alcohol vapors in the air. Use as little alcohol as possible. Follow all applicable federal, state, and local ordinances (in Germany: ZH 1/598). Only place clean, disinfected tools/aids in the test chamber. Limit the tools/aids to a minimum, e.g., no writing utensils, packaging, or similar materials. If larger objects or aids are placed in the test chamber, the retention capability (personal protection) of the safety cabinet may be impaired. Only set up equipment towards the back of the work surface. The uninterrupted airflow through the working openings of these safety cabinets and the low-turbulence displacement flow (laminar flow) in the test chamber are decisive factors for personal and product protection. Avoid any negative influences on the airflow while working in the test chamber. These can be the result of: - Rapid hand, arm, or body movements both in, as well as in front of the test chamber. Working Guidelines Aside from the information previously provided in the "Safety Information" section, please also not the following: No work may be performed in the test chamber if optical or acoustic alarms are on. The microbiological effectiveness and safety of the unit depends to a great extent on the proper conduct of the individuals working with the safety cabinet. Follow all applicable federal, state, and local guidelines and the information in this handbook. Only raise or lower the front window electrically. Manual lifting can result in problems with the window mounting. Turn the safety cabinet on at least 15 minutes prior to starting work in order for the test chamber ventilation to reach proper equilibrium. The front window must be in its operating position to ensure safe working conditions. Always wear appropriate protective gear, e.g., gloves, face protector, and protective clothing. Remove all jewelry. - Covering the air vents in the work panel. - Large volume objects and equipment. - Rapidly moving equipment with , e.g., stirrers, etc. - Heat-generating equipment, e.g., Bunsen burners. If Bunsen burners must be used, employ only safety models. - Only employ equipment that generates heat if the ventilation system is switched on. Do not allow filter elements to be damaged by heat sources - Contamination Hazard - . Work interruptions: If work at the safety cabinet is interrupted, make sure that any contamination by materials released in the safety cabinet is prevented. Operate the safety cabinet in the standby mode, with the glass window sealed. Disinfect and clean the test chamber surfaces regularly. Use only lint-free materials to wipe down test chamber surfaces. Always run the ventilator during all disinfecting work. Recommended disinfecting agent: 20/27 50 047 299 ">
/
Prenesi
Samo prijazen opomnik. Dokument si lahko ogledate tukaj. Najpomembneje pa je, da ga je naša umetna inteligenca že prebrala. Lahko razloži zapletene stvari na preprost način, odgovori na vaša vprašanja v katerem koli jeziku in vam pomaga hitro krmariti tudi po najdaljših ali najbolj zapletenih dokumentih.
Oglas