1

SEE // H E A R // F E E L

THE QUIETCOOL DIFFERENCE

QUIETCOOLSYSTEMS.COM

2

GENERAL SAFETY INSTRUCTIONS

1. Read Instructions - All safety and operation instructions must be read.

2. Retain Instructions - The safety and operating instructions should be kept for future

reference.

3.

4.

Heed Warnings - All warnings should be followed.

Follow Instructions - All installation and operating instructions should be followed.

5. Water – The QuietCool system should not be used near water. If you live in a very humid climate, be sure to cover your damper box with insulation to reduce condensation.

6.

7.

Heat - The QuietCool system should be situated away from heat sources.

Damage Requiring Service - Only qualified service personnel should service the

QuietCool system. The user should not attempt to service the product.

CONTENTS

1. SYSTEM OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1-2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1-3 Key Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

2-1 Installing the Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

2-2 Wiring the Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

2-3 Fan Hub LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3. OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3-1 Donwloading the App . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3-2 Operating the App . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

3-3 Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

ATTIC FAN SMART CONTROL WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

ADVANCED WHOLE HOUSE FANS

®

QC Manufacturing, Inc.

26040 Ynez Rd.

Temecula, CA 92591

PH 951.325.6340

FX 951.325.6351

QuietCoolSystems.com

INCLUDED IN THE BOX

- IT-AF-SMT Smart Attic Fan Control Hub - QuietCool Owner’s Guide

QUIETCOOLSYSTEMS.COM

STOP! READ ALL INSTRUCTIONS IN THIS GUIDE BEFORE INSTALLING YOUR

QUIETCOOL SYSTEM

Read this guide before proceeding! The manufacturer is NOT responsible for faulty installation or product damages caused through failure to fully read this guide BEFORE attempting installation.

FCC Regulations

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Caution

Changes or modifications not expressly approved by the part responsible for compliance could void the user's authority to operate the equipment.

1. SYSTEM OVERVIEW

1-1 INTRODUCTION

Congratulations on the purchase of your new QuietCool Smart Attic Fan

Control!

The QuietCool Smart Attic Fan Control is the smartest way to control your QuietCool

Advanced Attic Fans!

The QuietCool Smart Attic Fan Control allows users to control their attic fan, activate smart mode, and adjust the settings of their attic fan from our innovative phone app.

1-2 Features

• Smart Mode with temperature and humidity settings to keep your attic at the optimum

temperature and humiidity level

• Set countdown time for your QuietCool attic fan (up to 12 hours)

• Adjust speed setting for your QuietCool attic fan

1-3 Key Specifications

IT-AF-SMT Hub:

Voltage: 120V

Frequency: 60Hz

Motor load: 1HP, 735W (Max)

UL Rated Operating Temp 14°F - 149°F

The listing of this product allows it to be installed in confined spaces with temperatures that exceed 120 degrees.

1-888-QUIETCOOL

3

4

2. INSTALLATION

TOOLS YOU WILL NEED

- Phillips screwdriver - Power-drill - Philips bit

2-1 Installing the Hub

IMPORTANT: If you are installing the Hub onto an existing QuietCool fan, be sure to shut off the power before attempting installation. If you are installing the Hub onto a new fan, perform all installation steps before plugging in the fan.

1. Open up the thermostat on your attic fan. Unwire the power cord and remove the plastic connector. Unwire the motor wires and remove the metal connector and flex from the thermostat.

2. Attach the metal connector and flex to one of the knockouts on the IT-AF-SMT hub. Attach the plastic power cord bushing in another knockout on the hub.

2-2 Wiring the Hub

NOTE: Wiring Diagrams are for examples only and wiring should be done by an experienced electrician. 12 or 14-gauge romex is common. Check your local building code before choosing the wire type.

NOTE: Ensure the power is disconnected before performing any wiring

connections.

NOTE: The wiring diagrams and instructions are shown using the power cord included with your QuietCool. The installation can also be performed with

2-wire romex and hard wired.

One Speed Wiring (see Figure A)

1. Using a wire nut, connect the black wire from the power cord to the black wire from the

Hub.

2.

Connect the white wire from the power cord and the white wire on the fan to the white wire from the Hub.

3. Connect the black wire from the fan to the blue wire on the Hub

4. Cap the red wire on the Hub.

5. Cap the yellow wire from the Hub.

6. Ground the green wire from the fan and the green wire from the power cord to the ground screw in the Hub.

QUIETCOOLSYSTEMS.COM

7. Set the dip switch positions inside the Hub as shown in the diagram below.

Figure A

1 - ON

2 - OFF

8.

Power-on the Hub. The

Power LED indicator will be lit.

9.

Press the Test button to make sure the fan works.

The Test LED indicator will blink once every two seconds indicating

1-speed and the fan will be on. Press the Test button again and the fan should shut off and the LED will be off.

10.

If the fan doesn’t operate as described in step 9, please check the dip switch postion.

Two Speed Wiring (see Figure B)

1. Using a wire nut, connect the black wire from the power cord to the black wire from the

Hub.

2. Connect the white wire from the power cord and the white wire on the fan to the white wire from the Hub.

Figure B

3. Connect the black wire from the fan to the blue wire on the Hub

4. Connect the red wire from the fan to the red wire on the Hub

5. Cap the yellow wire from the Hub.

6. Ground the green wire from the fan and the green wire from the power cord to the ground screw in the

Hub.

7. Set the dip switch positions inside the Hub as shown in the Figure B.

1-888-QUIETCOOL

5

6

8. Power-on the Hub. The Power LED indicator will be lit.

9. Press the Test button to make sure the fan works. The Test LED indicator will blink twice every two seconds indicating 2-speed and the fan will be on high. Press the Test button again and the fan will switch to low speed. Press the Test button again and the fan should shut off and the LED will be off.

10. If the fan doesn’t operate as described in step 9, please check the dip switch postion.

Three Speed Wiring (for AFG SMT-3.0) (see Figure C)

1. Using a wire nut, connect the black wire from the power cord and the black wire from the fan to the black wire from the Hub.

2.

Connect the white wire from the power cord and the white wire on the fan to the white wire from the

Hub.

Figure C

2 - OFF

3 - ON

3.

Connect the red wire from the fan to the red wire on the Hub

4.

Connect the yellow wire from the fan to the yellow wire on the Hub

5.

Connect the blue wire from the fan to the blue wire on the Hub

6.

Ground the green wire from the fan and the green wire from the power cord to the ground screw in the Hub.

7. Set the dip switch positions inside the Hub as shown in the diagram below.

8. Power-on the Hub. The Power LED indicator will be lit.

9. Press the Test button to make sure the fan works. The Test LED indicator will blink three times every two seconds indicating 3-speed and the fan will be on high. Press the Test button again and the fan will switch to medium speed. Press the Test button again and the fan will switch to low speed. Press the Test button again and the fan should shut off and the LED will be off.

10. If the fan doesn’t operate as described in step 9, please check the dip switch postion.

QUIETCOOLSYSTEMS.COM

2-3 Fan Hub LED Indicators

Power Indicator

• The Power LED indicator will always be lit when the Hub is connected to Power.

• If this LED is not lit, check the power source

Timer Indicator

• The Timer LED indicator will light up as shown below:

1.

2.

3.

1 Hour: 1 Blink

2 Hours: 2 Blinks

4 Hours: 4 Blinks

4.

5.

8 Hours: 8 Blinks

12 Hours: 12 Blinks

6. Continuous On: Off

POWER TIMER

TEST PAIR

Test Indicator

• The Test LED indicator will light up as shown below when the Test button is pressed:

1.

One Speed Fan: blink once every 2 seconds

2. Two Speed Fan: blink twice every 2 seconds

3. Three Speed Fan: blink three times every 2 seconds

Pair Indicator

• The Pair LED indicator will light up when making pair operations. Please see page 12 for details on pairing.

3. OPERATION

3-1 Downloading the QuietCool Smart Control App

Download the QuietCool Smart Control App onto your iOS or Android device.

Visit QuietCoolSystems.com/beta/ and click the link to download the app to your device.

Scan this QR code to download the

QuietCool Smart Control App

1-888-QUIETCOOL

7

8

3-2 Operating the QuietCool Smart Control App

When you first connect to your QuietCool Smart Attic Fan

Control, your attic fan will show up in the list of available fans in the app.

A message indicates that setup is required. Press and hold the

Pair button on the Hub until the LED indicator begins to blink.

NOTE: You will need to initiate this Pairing process on each device you want to use to control your attic fan.

Tap on the fan to start the setup process. Once you tap on the fan, you will go to to the Fan Setup page.

On this page, you will be able to change the name of your fan.

Simply tap the current fan name and you will be able to name it whatever you would like.

The Speeds Available section will tell you if you have connected the fan and set your dip switch properly. Make sure that this number matches the specification of the fan you purchased.

The QuietCool Smart Attic Fan Control has an innovative

Smart mode that allows the fan to adjust the speed based on the temperature and humidity conditions in your attic. Tap

Temperature & Humidity Settings to adjust these settings.

Within this mode there are two standard presets, Summer and

Winter. You can modify these presets and add your own custom presets to allow quick settings changes on the fly.

Temperature

• The settings you choose in this section will change what temperature the fan will come on at each set speed.

• Tap on either Low or High speed to adjust the temperature for each speed.

• Note: Low Speed must be set at a lower speed than High

Speed.

Humidity

• Turn Fan Off: This is the humidity percentage that will cause the fan to turn off. For example, if it is set at 90%, the fan will turn off if the humidity in the attic is 90% or higher.

• Turn Fan On: This is the humidity percentage that will cause the fan to turn on. For example, if it is set at 70%, the fan will turn on if the humidity in the attic is higher than 70%.

• Desired Speed: This is the speed the fan will use if the humidity causes the fan to turn on.

QUIETCOOLSYSTEMS.COM

1-888-QUIETCOOL

Once setup is complete, tap Done in the Fan Setup page.

Now you can tap the fan on the home page. You will be taken to the Fan Control page.

On the Fan Control page, you will see the current fan status, the current attic temperature, as well as the current attic humidity level.

You also have the option to Activate Smart Mode or Activate

Timer Mode. You can also go into the settings of the fan and adjust the settings that you setup in the first step.

Smart Mode

Smart Mode will automatically change the speed based on the attic temperature and humidity.

To activate Smart Mode, simply tap Activate Smart Mode.

Regardless of the attic temperature, if the current attic humidity percentgage is over the Turn Fan Off Humidity setting, the fan will shut off. Once the humidity in the attic is back under that setting, the temperature sensor will become active again to control the fan.

Timer Mode

Timer Mode is a simple way to turn your attic fan on for a set amount of time at a set speed.

To activate Timer Mode, simply tap Activate Timer Mode.

Once activated, you can select your speed by tapping Set Speed.

You can also select your runtime by tapping Set Time.

When Timer Mode is active, you will see your remaining time left on the timer at the top of the screen.

9

10

3-3 Frequently Asked Questions

What protocal does this control use?

This control operates over Bluetooth to connect to your phone.

Will my neighbor be able to control my fan if they have the same set up as me?

No. In order to connect to your Smart Attic Fan Control Hub, you must first pair your device by using the Pair button on the Hub.

What is the range?

The range restriction between your phone and the attic fan is 50 ft.

Why are all my lights solid on the hub and nothing is working?

If you’re experiencing solid lights on the hub then it is an indication that your DIP switches are not in the correct position. Disconnect power, adjust your DIP switches, and the only light that should be lit is your RED power light.

How do I change the DIP switch to the correct speed of my fan?

You will need to disconnect power, make your adjustment inside the hub, and then reconnect power.

Can you connect the Attic Fan Smart Control to a smart home system like Alexa, Google

Home, or Apple HomeKit?

No, in the current configuration the Smart Attic Fan Control cannot connect to a smart home system.

QUIETCOOLSYSTEMS.COM

ATTIC FAN SMART CONTROL LIMITED WARRANTY

QC Manufacturing Inc. extends this warranty to the original purchaser of the following -

IT-AF-SMT - installed and used in a residence under normal conditions within the

United States:

A.

One year coverage applies to the product. At our option we will repair or replace any part of the assembly should it fail to operate during the first year from the date of original purchase.

B.

This warranty does not cover any of the following:

1. Accidental or consequential damage resulting from the operation of our equipment or any malfunction thereof.

2. Cost of service calls to diagnose the cause of problems or the labor charge to un-install any components.

3. Product failure or damage due to faulty installation, abuse, misuse, unauthorized alteration to factory specs, lack of maintenance, or transportation damage.

4. Shipping or postage for warranty claims.

C.

To obtain service under this warranty, first contact the dealer where you purchased the equipment. If you are unable to find or reach your dealer, contact Customer Service at QC Manufacturing, Inc. at the number below.

D.

Registration is no longer required . If service is required under this warranty, you must retain your proof or purchase.

This warranty is the only warranty extended by QC Manufacturing, Inc. to purchasers or suppliers of our equipment. QC Manufacturing Inc. disclaims all other warranties, express or implied, that arise by operation of the law.

1-888-QUIETCOOL

QC Manufacturing, Inc. Customer Service

26040 Ynez Rd.

Temecula, CA 9259 1 www.QuietCoolSystems.com

951-325-6340

Rev. 11-19-19