G310 Data Sheet/Manual PDF


Add to my manuals
8 Pages

advertisement

G310 Data Sheet/Manual PDF | Manualzz

Bulletin No. G310-J

Drawing No. LP0581

Released 1/08

Tel +1 (717) 767-6511

Fax +1 (717) 764-0839 www.redlion.net

MODEL G310 - GRAPHIC LCD OPERATOR INTERFACE TERMINAL WITH

VGA DISPLAY AND TOUCHSCREEN

63YN

LABORATORY EQUIPMENT

FOR USE IN HAZARDOUS LOCATIONS:

Class I, Division 2, Groups A, B, C, and D

Class II, Division 2, Groups F and G

Class III, Division 2

O

Configured using Crimson software (version 2.0 or later)

O

Up to 5 RS-232/422/485 communications ports

(2 RS-232 and 1 RS-422/485 on board, 1 RS-232 and 1 RS422/485 on optional communications card)

O

10 Base T/100 Base-TX Ethernet Port to network units and host web pages

O

USB Port to download the unit’s configuration from a PC or for data transfers to a PC

O

Unit’s configuration is stored in non-volatile memory (8Mbyte Flash)

O

CompactFlash ® Socket to increase memory capacity

O

10.4-inch TFT 256 Color VGA 640x480 pixel LCD

O

Sunlight Visible Outdoor Unit with UV rated overlay available

O

8-button keypad for on-screen menus

O

Three front panel LEDs

O

Power unit from 24VDC ±20% supply

O

Resistive Analog Touchscreen

GENERAL DESCRIPTION

The G310 Operator Interface Terminal combines unique capabilities normally expected from high-end units with a very affordable price. It is built around a high performance core with integrated functionality. This core allows the G310 to perform many of the normal features of the Paradigm range of

Operator Interfaces while improving and adding new features.

The G310 is able to communicate with many different types of hardware using high-speed RS232/422/485 communications ports and Ethernet 10 Base T/100

Base-TX communications. In addition, the G310 features USB for fast downloads of configuration files and access to trending and data logging. A CompactFlash socket is provided so that Flash cards can be used to collect your trending and data logging information as well as to store larger configuration files.

In addition to accessing and controlling of external resources, the G310 allows a user to easily view and enter information. A sunlight visible outdoor version is available for direct sunlight applications. Users can enter data through the touchscreen or front panel 8-button keypad.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the controller.

The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system.

WARNING - EXPLOSION HAZARD - SUBSTITUTION OF

COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,

DIVISION 2/CLASS II, DIVISION 2/CLASS III, DIVISION 2

CAUTION: Risk Of Danger.

Read complete instructions prior to installation and operation of the unit.

CAUTION: Risk of electric shock.

CompactFlash is a registered trademark of CompactFlash Association.

CONTENTS OF PACKAGE

- G310 Operator Interface.

- Panel Gasket.

- This hardware bulletin.

- Template for panel cutout.

- Hardware packet for mounting unit into panel.

- Terminal block for connecting power.

ORDERING INFORMATION

MODEL NO.

DESCRIPTION PART NUMBER

Operator Interface for indoor applications only, textured finish with embossed keys

G310

Operator Interface for indoor or outdoor applications, glossy finish with UV rated overlay (keys are not embossed)

G3CF

64 MB CompactFlash Card 5

256 MB CompactFlash Card 5

512 MB CompactFlash Card 5

RS 232/485 Optional Communication Card G3RS

G3CN

G3PBDP

CANopen Optional Communication Card

Profibus DP Optional Communication Card

SFCRM2 Crimson 2

CBL

DR

G3FILM

RS-232 Programming Cable

USB Cable

Communications Cables 1

DIN Rail Mountable Adapter Products 3

Replacement Battery 4

G310C Backlight Replacement 6

G310S Backlight Replacement 6

Protective Films

G310C000

G310S000

G3CF064M

G3CF256M

G3CF512M

G3RS0000

G3CN0000

G3PBDP00

SFCRM200

CBLPROG0

CBLUSB00

CBLxxxxx

DRxxxxxx

BNL20000

G3BR10C0

G3BR10S0

G3FILM10

1

2

3

4

5

6

Contact your Red Lion distributor or visit our website for complete selection.

Use this part number to purchase Crimson on CD with a printed manual, USB cable, and RS-232 cable. Otherwise, download for free from www.redlion.net.

Red Lion offers RJ modular jack adapters. Refer to the DR literature for complete details.

Battery type is lithium coin type CR2025

Industrial grade two million write cycles.

For use in non-hazardous locations only.

1

S

PECIFICATIONS

1. POWER REQUIREMENTS:

G310C: +24 VDC ±20% @ 33 W maximum.

G310S: +24 VDC ±20% @ 50 W maximum.

Must use Class 2 or SELV rated power supply.

Power connection via removable three position terminal block.

Notes:

1. The front panel PWR LED indicates power.

2. The G310’s circuit common is not connected to the enclosure of the unit. See “Connecting to Earth Ground” in the section “Installing and

Powering the G310.”

2. BATTERY: Lithium coin cell. Typical lifetime of 10 years.

3. LCD MODULE DISPLAYS:

MODEL

SIZE

TYPE

COLORS

PIXELS

BRIGHTNESS

BACKLIGHT*

G310C

10.4-inch

TFT

256 VGA

640 X 480

450 cd/m 2

50,000 HR TYP.

G310S

10.4-inch

TFT

256 VGA

640 X 480

850 cd/m 2

20,000 HR TYP.

*Lifetime at room temperature. Refer to “Display” in the “Software/Unit

Operation” section.

4. 8-KEY KEYPAD: for on-screen menus.

5. TOUCHSCREEN: Resistive analog

6. MEMORY:

On Board User Memory: 8 Mbyte of onboard non-volatile Flash memory.

Memory Card: CompactFlash Type II slot for Type I and Type II

CompactFlash cards.

7. COMMUNICATIONS:

USB Port: Adheres to USB specification 1.1. Device only using Type B connection.

WARNING - DO NOT CONNECT OR DISCONNECT CABLES

WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE

NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND

DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT

CONNECTION.

Serial Ports: Format and Baud Rates for each port are individually software programmable up to 115,200 baud.

PGM Port: RS232 port via RJ12.

COMMS Ports: RS422/485 port via RJ45, and RS232 port via RJ12.

DH485 TXEN: Transmit enable; open collector, V

OH

V

OL

= 0.5 V @ 25 mA max.

= 15 VDC,

Note: For additional information on the communications or signal common and connections to earth ground please see the “Connecting to

Earth Ground” in the section “Installing and Powering the G310.”

Ethernet Port: 10 BASE-T / 100 BASE-TX

RJ45 jack is wired as a NIC (Network Interface Card).

8. ENVIRONMENTAL CONDITIONS:

Operating Temperature Range: 0 to 50°C

Storage Temperature Range: G310C: -20 to 70°C

G310S: -20 to 60°C

Operating and Storage Humidity: 80% maximum relative humidity (noncondensing) from 0 to 50°C.

Vibration According to IEC 68-2-6: 10 to 55 Hz, in X, Y, Z direction for 1.5

hours, 1 g.

Shock According to IEC 68-2-27: Operational 30 g, 9 msec in 3 directions.

Altitude: Up to 2000 meters.

9. CERTIFICATIONS AND COMPLIANCES:

SAFETY

UL Recognized Component, File #E179259, UL61010-1, CSA 22.2 No.61010-1

Recognized to U.S. and Canadian requirements under the Component

Recognition Program of Underwriters Laboratories, Inc.

UL Listed, File #E211967, UL61010-1, UL1604, CSA 22.2 No. 61010.1,

CSA 22.2 No. 213-M1987

LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards

Type 4X Enclosure rating (Face only), UL50

IECEE CB Scheme Test Certificate #US/9737C/UL,

CB Scheme Test Report #E179259-V01-S04

Issued by Underwriters Laboratories Inc.

IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1.

IP66 Enclosure rating (Face only), IEC 529

ELECTROMAGNETIC COMPATIBILITY

Emissions and Immunity to EN 61326: Electrical Equipment for

Measurement, Control and Laboratory use.

Immunity to Industrial Locations:

Electrostatic discharge EN 61000-4-2

Electromagnetic RF fields

Fast transients (burst)

Surge

RF conducted interference

EN 61000-4-3

EN 61000-4-4

EN 61000-4-5

EN 61000-4-6

Criterion A

4 kV contact discharge

8 kV air discharge

Criterion A

10 V/m

Criterion A

2 kV power

2 kV signal

Criterion A

1 kV L-L,

2 kV L&N-E power

Criterion B

3 V/rms

Emissions:

Emissions EN 55011 Class A

Notes:

1. Criterion A: Normal operation within specified limits.

2. Criterion B: Temporary loss of performance from which the unit selfrecovers.

10. CONNECTIONS: Compression cage-clamp terminal block.

Wire Gage: 12-30 AWG copper wire

Torque: 5-7 inch-pounds (56-79 N-cm)

11. CONSTRUCTION: Steel rear metal enclosure with NEMA 4X/IP66 aluminum front plate when correctly fitted with the gasket provided.

Installation Category II, Pollution Degree 2.

12. MOUNTING REQUIREMENTS: Maximum panel thickness is 0.25" (6.3

mm). For NEMA 4X/IP66 sealing, a steel panel with a minimum thickness of

0.125" (3.17 mm) is recommended.

Maximum Mounting Stud Torque: 17 inch-pounds (1.92 N-m)

13. WEIGHT: 5.53 lbs (2.51 Kg)

DIMENSIONS In inches (mm)

2

I

NSTALLING AND

P

OWERING THE

G310

MOUNTING INSTRUCTIONS

This operator interface is designed for through-panel mounting. A panel cutout diagram and a template are provided. Care should be taken to remove any loose material from the mounting cut-out to prevent that material from falling into the operator interface during installation. A gasket is provided to enable sealing to NEMA 4X/IP66 specification. Install the 14 kep nuts provided and tighten evenly for uniform gasket compression.

Note: Tightening the kep nuts beyond a maximum of 17 inch-pounds (1.92

N-m) may cause damage to the front panel.

The chassis ground is not connected to signal common of the unit.

Maintaining isolation between earth ground and signal common is not required to operate your unit. But, other equipment connected to this unit may require isolation between signal common and earth ground. To maintain isolation between signal common and earth ground care must be taken when connections

are made to the unit. For example, a power supply with isolation between its signal common and earth ground must be used. Also, plugging in a USB cable may connect signal common and earth ground.

1

1. USB’s shield may be connected to earth ground at the host. USB’s shield in turn may also be connected to signal common.

All tolerances ±0.010" (±0.25 mm).

POWER SUPPLY REQUIREMENTS

The G310C requires a 24 VDC power supply rated at 33 W, and the G310S requires a 24 VDC power supply rated at 50 W. Your unit may draw considerably less the rated power depending upon the options being used. As additional features are used your unit will draw increasing amounts of power.

Items that could cause increases in current are additional communications, optional communications card, CompactFlash card, and other features programmed through Crimson.

In any case, it is very important that the power supply is mounted correctly if the unit is to operate reliably. Please take care to observe the following points:

– The power supply must be mounted close to the unit, with usually not more than 6 feet (1.8 m) of cable between the supply and the operator interface. Ideally, the shortest length possible should be used.

– The wire used to connect the operator interface’s power supply should be at least 22-gage wire. If a longer cable run is used, a heavier gage wire should be used. The routing of the cable should be kept away from large contactors, inverters, and other devices which may generate significant electrical noise.

– A power supply with a Class 2 or SELV rating is to be used. A Class 2 or SELV power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults. SELV is an acronym for “safety extra-low voltage.” Safety extra-low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault, such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred.

ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING

DIVISION 2 WIRING METHODS AS SPECIFIED IN ARTICLE 501-

4 (b), 502-4 (b), AND 503-3 (b) OF THE NATIONAL ELECTRICAL

CODE, NFPA 70 FOR INSTALLATION WITHIN THE UNITED

STATES, OR AS SPECIFIED IN SECTION 19-152 OF CANADIAN

ELECTRICAL CODE FOR INSTALLATION IN CANADA.

CONNECTING TO EARTH GROUND

The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system.

Each G310 has a chassis ground terminal on the back of the unit. Your unit should be connected to earth ground (protective earth).

C

OMMUNICATING

W

ITH THE

G310

CONFIGURING A G310

The G310 is configured using Crimson software. Crimson is available as a free download from Red Lion’s website, or it can be purchased on CD. Updates to

Crimson for new features and drivers are posted on the website as they become available. By configuring the G310 using the latest version of Crimson, you are assured that your unit has the most up to date feature set. Crimson software can configure the G310 through the RS232 PGM port, USB port, or CompactFlash.

The USB port is connected using a standard USB cable with a Type B connector. The driver needed to use the USB port will be installed with Crimson.

If this driver has not been installed, it can be downloaded from the website.

The RS232 PGM port uses a programming cable made by Red Lion to connect to the DB9 COM port of your computer. If you choose to make your own cable, use the “G310 Port Pin Out Diagram” for wiring information.

The CompactFlash can be used to program a G3 by placing a configuration file and firmware on the CompactFlash card. The card is then inserted into the target G3 and powered. Refer to the Crimson literature for more information on the proper names and locations of the files.

USB, DATA TRANSFERS FROM THE

COMPACTFLASH CARD

WARNING - DO NOT CONNECT OR DISCONNECT CABLES

WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE

NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND

DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT

CONNECTION.

In order to transfer data from the CompactFlash card via the USB port, a driver must be installed on your computer. This driver is installed with Crimson and is located in the folder C:\Program Files\Red Lion Controls\Crimson

2.0\Device\ after Crimson is installed. This may have already been accomplished if your G310 was configured using the USB port.

Once the driver is installed, connect the G310 to your PC with a USB cable, and follow “Mounting the CompactFlash” instructions in the Crimson 2 user manual.

CABLES AND DRIVERS

Red Lion has a wide range of cables and drivers for use with many different communication types. A list of these drivers and cables along with pin outs is available from Red Lion’s website. New cables and drivers are added on a regular basis. If making your own cable, refer to the “G310 Port Pin Outs” for wiring information.

3

ETHERNET COMMUNICATIONS

Ethernet communications can be established at either 10 BASE-T or 100

BASE-TX. The G310 unit’s RJ45 jack is wired as a NIC (Network Interface

Card). For example, when wiring to a hub or switch use a straight-through cable, but when connecting to another NIC use a crossover cable.

The Ethernet connector contains two LEDs. A yellow LED in the upper right, and a bi-color green/amber LED in the upper left. The LEDs represent the following statuses.

LED COLOR

YELLOW solid

YELLOW flashing

GREEN

AMBER

DESCRIPTION

Link established.

Data being transferred.

10 BASE-T Communications

100 BASE-TX Communications

The Crimson manual contains additional information on Ethernet communications.

RS232 PORTS

The G310 has two RS232 ports. There is the PGM port and the COMMS port.

Although only one of these ports can be used for programming, both ports can be used for communications with a PLC.

The RS232 PGM port can be used for either master or slave protocols with any G310 configuration.

Examples of RS232 communications could involve another Red Lion product or a PC. By using a cable with RJ12 ends on it, and a twist in the cable, RS232 communications with another G3 product or the Modular Controller can be established. Red Lion part numbers for cables with a twist in them are

CBLPROG0 1 , CBLRLC01 2 , or CBLRC02 3 .

G3 RS232 to a PC

G3: RJ12

4

5

2

3

1

6

Name

COMM

Connections

PC: DB9

1

Tx

Rx

N/C

COM

N/C

CTS

RTS

N/C

7

8

9

4

5

6

2

3

Name

DCD

Rx

Tx

DTR

GND

DSR

RTS

CTS

RI

1 CBLPROG0 can also be used to communicate with either a PC or an ICM5.

2

3

DB9 adapter not included, 1 foot long.

DB9 adapter not included, 10 feet long.

G310 PORT PIN OUTS

4

RS422/485 COMMS PORT

The G310 has one RS422/485 port. This port can be configured to act as either RS422 or RS485.

RS422/485 4-WIRE

CONNECTIONS

RS485 2-WIRE

CONNECTIONS

DH485 COMMUNICATIONS

The G310’s RS422/485 COMMS port can also be used for Allen Bradley

DH485 communications.

WARNING: DO NOT use a standard DH485 cable to connect this port to Allen

Bradley equipment. A cable and wiring diagram are available from Red Lion.

RJ45: RLC

1

2

3, 8

4, 7

5

6

4, 7

3, 8

G3 to AB SLC 500 (CBLAB003)

Name

Connections

RJ45: A-B

TxB

TxA

RxA

RxB

TxEN

COMM

TxB

TxA

1

2

-

-

5

4

-

-

Name

A

B

24V

COMM

TxEN

SHIELD

COMM

24V

Note: All Red Lion devices connect A to A and B to B, except for Paradigm devices. Refer to www.redlion.net for additional information.

Examples of RS485 2-Wire Connections

G3 to Red Lion RJ11 (CBLRLC00)

DLC, IAMS, ITMS, PAXCDC4C

G3: RJ45

5

6

1

2

Name

Connections

RLC: RJ11

TxEN

COM

TxB

TxA

2

3

5

4

Name

TxEN

COM

B-

A+

G3

1,4

4,1

2,3

3,2

5

6

7

8

G3 to Modular Controller (CBLRLC05)

RxB

TxA

RxA

TxEN

COM

TxB

TxA

Name

TxB

Connections

Modular Controller

1,4

5

6

7

8

4,1

2,3

3,2

Name

TxB

RxB

TxA

RxA

TxEN

COM

TxB

TxA

5

S

OFTWARE

/U

NIT

O

PERATION

CRIMSON SOFTWARE

Crimson software is available as a free download from Red Lion’s website or it can be purchased on a CD, see “Ordering Information” for part number. The latest version of the software is always available from the website, and updating your copy is free.

KEYPAD

The G310 keypad consists of eight keys for on-screen menus.

TOUCHSCREEN

This operator interface utilizes a resistive analog touchscreen for user input.

The unit will only produce an audible tone (beep) when a touch on an active touchscreen cell in sensed. The touchscreen is fully functional as soon as the operator interface is initialized, and can be operated with gloved hands.

DISPLAY

This operator interface uses a liquid crystal display (LCD) for displaying text and graphics. The display utilizes a cold cathode fluorescent tube (CCFL) for lighting the display. The CCFL tubes can be dimmed for low light conditions.

These CCFL tubes have a limited lifetime. Backlight lifetime is based upon the amount of time the display is turned on at full intensity. Turning the backlight off when the display is not in use can extend the lifetime of your backlight. This can be accomplished through the Crimson software when configuring your unit.

TROUBLESHOOTING YOUR G310

If for any reason you have trouble operating, connecting, or simply have questions concerning your new G310, contact Red Lion’s technical support.

For contact information, refer to the back page of this bulletin for phone and fax numbers.

BACKLIGHT REPLACEMENT

CAUTION:

Backlight is not field replaceable for hazardous location applications. Unit must be returned to Red Lion Controls for repair.

EMAIL: [email protected]

Web Site: http://www.redlion.net

The backlight assembly is field replaceable in non-hazardous locations only.

Refer to the instructions included in the appropriate backlight replacement kit.

FRONT PANEL LEDS

There are three front panel LEDs. Shown below is the default status of the LEDs.

LED INDICATION

RED (TOP, LABELED “PWR”)

FLASHING Unit is in the boot loader, no valid configuration is loaded.

1

STEADY Unit is powered and running an application.

YELLOW (MIDDLE)

OFF No CompactFlash card is present.

Valid CompactFlash card present.

STEADY

FLASHING

RAPIDLY

CompactFlash card being checked.

FLICKERING

Unit is writing to the CompactFlash, either because it is storing data, or because the PC connected via the USB port has locked the drive.

2

FLASHING

SLOWLY

Incorrectly formatted CompactFlash card present.

GREEN (BOTTOM)

FLASHING A tag is in an alarm state.

STEADY Valid configuration is loaded and there are no alarms present.

1. The operator interface is shipped without a configuration. After downloading a configuration, if the light remains in the flashing state continuously, try cycling power. If the LED still continues to flash, try downloading a configuration again.

2. Do not turn off power to the unit while this light is flickering. The unit writes data in two minute intervals. Later Microsoft operating systems will not lock the drive unless they need to write data; Windows 98 may lock the drive any time it is mounted, thereby interfering with logging. Refer to

“Mounting the CompactFlash” in the Crimson 2 User Manual.

6

BATTERY & TIME KEEPING

WARNING - EXPLOSION HAZARD - THE AREA MUST BE

KNOWN TO BE NON-HAZARDOUS BEFORE SERVICING/

REPLACING THE UNIT AND BEFORE INSTALLING OR

REMOVING I/O WIRING AND BATTERY.

WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT

EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED

AND THE AREA IS KNOWN TO BE NON-HAZARDOUS.

A battery is used to keep time when the unit is without power. Typical accuracy of the G310 time keeping is less than one minute per month drift. The battery of a G310 unit does not affect the unit’s memory, all configurations and data is stored in non-volatile memory.

CAUTION: RISK OF ELECTRIC SHOCK

The inverter board, attached to the mounting plate, supplies the high voltage to operate the backlight. Touching the inverter board may result in injury to personnel.

CAUTION: The circuit board contains static sensitive components. Before handling the operator interface without the rear cover attached, discharge static charges from your body by touching a grounded bare metal object. Ideally, handle the operator interface at a static controlled clean workstation. Also, do not touch the surface areas of the circuit board. Dirt, oil, or other contaminants may adversely affect circuit operation.

To change the battery of a G310, remove power, cabling, and then the rear cover of the unit. To remove the cover, remove the five screws designated by the arrows on the rear of the unit. Then, by lifting the top side, hinge the cover, thus providing clearance for the connectors on the bottom side of the PCB as shown in the illustration below. Install in the reverse manner.

Remove the old battery* from the holder and replace with the new battery.

Replace the rear cover, cables, and re-apply power. Using Crimson or the unit’s keypad, enter the correct time and date.

G310C

G310S

* Please note that the old battery must be disposed of in a manner that complies with your local waste regulations. Also, the battery must not be disposed of in fire, or in a manner whereby it may be damaged and its contents come into contact with human skin.

The battery used by the G310 is a lithium type CR2025.

7

O

PTIONAL

F

EATURES AND

A

CCESSORIES

INDOOR VERSUS OUTDOOR

Red Lion offers two versions of its G310 unit. The G310C000 uses an overlay with a textured finish and keys that are embossed. This overlay is not rated for outdoor use. The G310S000 uses an overlay with a glossy finish that uses UV rated material for outdoor use. The keys on this overlay are not embossed. The display is significantly brighter than the G310C000.

OPTIONAL COMMUNICATION CARD

Red Lion offers optional communication cards for fieldbus communications.

These communication cards will allow your G310 to communicate with many of the popular fieldbus protocols.

Red Lion is also offering a communications card for additional RS232 and

RS422/485 communications. Visit Red Lion’s website for information and availability of these cards.

CUSTOM LOGO

Each G3 operator interface has an embossed area containing the Red Lion logo. Red Lion can provide custom logos to apply to this area. Contact your distributor for additional information and pricing.

COMPACTFLASH SOCKET

CompactFlash socket is a Type II socket that can accept either Type I or II cards. Use cards with a minimum of 4 Mbytes and a maximum of 2 Gbytes with the G310’s CompactFlash socket. Cards are available at most computer and office supply retailers.

CompactFlash can be used for configuration transfers, larger configurations, data logging, and trending.

Note: Do not remove or insert the CompactFlash card while power is applied. Refer to

“Front Panel LEDs.”

Information stored on a CompactFlash card by a G310 can be read by a card reader attached to a PC. This information is stored in IBM (Windows ® ) PC compatible FAT16 file format.

NOTE

For reliable operation in all of our products, Red Lion recommends the use of SanDisk ® and SimpleTech brands of CompactFlash cards.

Industrial grade versions that provide up to two million write/erase cycles minimum are available from Red Lion.

Red Lion Controls

20 Willow Springs Circle

York PA 17406

Tel +1 (717) 767-6511

Fax +1 (717) 764-0839

LIMITED WARRANTY

The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions.

The Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The

Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products.

The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92-

573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or as amended hereafter.

No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein.

The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.

Red Lion Controls BV

Printerweg 10

NL - 3821 AD Amersfoort

Tel +31 (0) 334 723 225

Fax +31 (0) 334 893 793

Red Lion Controls AP

Unit 101, XinAn Plaza

Building 13, No.99 Tianzhou Road

ShangHai, P.R. China 200223

Tel +86 21 6113-3688

Fax +86 21 6113-3683

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement