XtremepowerUS 71048-XPH 1/2 HP Dirty and Clean Water Submersible Thermoplastic Utility Sump Pump Instructions

Add to My manuals
7 Pages

advertisement

XtremepowerUS 71048-XPH 1/2 HP Dirty and Clean Water Submersible Thermoplastic Utility Sump Pump Instructions | Manualzz

1/2HP SUBMERSIBLE WATER PUMP 2115GPH

ITEM: 71048-XP

OWNER’S MANUAL AND SAFETY INSTRUCTIONS

SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY,

OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT’S

SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH

AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER).

FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT: (909) 628 0880 MON-FRI 9AM TO 3PM PST

IMPORTANT SAFETY INFORMATION

GENERAL SAFETY WARNINGS

Read all safety warnings and instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.

SAFETY

The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury.

Read and understand all instructions.

Failure to follow all instructions may result in serious injury or property damage.

DO NOT allow persons to operate or assemble the product until they have read this manual and have developed a thorough understanding of how it works.

DO NOT modify this product in any way. Unauthorized modification may impair the function and/or safety and could affect the life of the product. There are specific applications for which the product was designed.

Use the right Pump for the job. DO NOT attempt to force a small Pump or attachment to do the work of a larger industrial Pump. There are certain applications for which this Pump was designed. DO NOT modify this Pump and DO NOT use this Pump for a purpose for which it was not intended.

Maintain Pump with care.

Inspect tool cords periodically and, if damaged, have them repaired by an authorized technician.

I nspect the work area before each use . Keep work area clean, dry, free of clutter, and well-lit.

Cluttered, wet, or dark work areas can result in injury.

DO NOT use the product where there is a risk of causing a fire or an explosion ; e.g., in the presence of flammable liquids, gases, or dust. The product can create sparks, which may ignite the flammable liquids, gases, or dust.

Guard against electric shock.

Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures. It is strongly recommended that this Pump be plugged into a

Ground Fault Circuit Interrupter (GFCI). Ask a local electrician for easy installation instructions. To avoid electrical shock, no person or animal should be in contact with the water being pumped. Never walk on wet or damp area when pump is running in the same room.

Keep children and bystanders away from the work area while operating the pump.

DO NOT allow children to handle the product.

1

IMPORTANT SAFETY INFORMATION

Stay alert, watch what you are doing, and use common sense when operating the tool. DO NOT use the tool while you are tired or under the influence of drugs, alcohol, or medication.

Dress properly. DO NOT wear loose clothing, dangling objects, or jewellery. Keep your hair, clothing and gloves away from moving parts. Loose clothes, jewellery, or long hair can be caught in moving parts.

Use eye and ear protection.

Always wear ANSI approved impact safety goggles. Wear an ANSI approved dust mask or respirator when working around metal, wood, and chemical dusts and mists.

DO NOT overreach. Keep proper footing and balance at all times.

Avoid unintentional starting. Dry running of the Pump causes excess wear.

Check for damaged parts before each use.

Carefully check that the product will operate properly and perform its intended function. Replace damaged or worn parts immediately. Never operate the product with a damaged part.

DO NOT operate Pump if under the influence of alcohol or drugs. Read warning labels on prescriptions to determine if your judgment or reflexes are impaired while taking drugs. If there is any doubt, DO NOT operate the Pump.

Use proper size and type extension cord.

If an extension cord is required, it must be of the proper size and type to supply the correct current to the tool without heating up. Otherwise, the extension cord could melt and catch fire, or cause electrical damage to the tool. This tool requires use of an extension cord of

0 to 10 amps capability (up to 50 feet), with wire size rated at 18 AWG. Longer extension cords require larger size wire. If you are using the tool outdoors, use an extension cord rated for outdoor use. (signified by “WA” on the jacket). Note: DO NOT make the extension cord connection underwater.

Maintenance. For your safety, maintenance should be performed regularly by a qualified technician.

DO NOT pump hazardous materials.

DO NOT pump explosive or flammable materials such as Fuel

Oil, Kerosene, Gasoline etc. DO NOT pump in close proximity to flammable or explosive materials. DO

NOT pump fats, oils, salt or waste water. This Pump is designed to move clean or dirty water. DO NOT pump hot liquid.

Water transfers in cycles.

DO NOT attempt to manipulate the switch to keep Pump running continuously.

It is meant to shut off intermittently. Doing so will damage the Pump.

WARNING: People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.

WARNING: Handling the cord on this product will expose you to lead, a chemical known to the

State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. (California Health & Safety Code § 25249.5, et seq.)

NOTE: Performance of this Pump (if powered by line voltage) may vary depending on variations in local line voltage. Extension cord usage may also affect Pump performance.

2

PRODUCT INFORMATION

FEATURES

Powered by a durable, oil-cooled electric motor

Various fittings for outflow included.

Heavy Duty Motor with thermal overload protection

About 25 Ft Cord Length

Foldable pump base for max drain

UL Listed

TETHER ADJUSTMENT

NOTCH

UNIVERSAL

FITTING

ADJUSTABLE

FLOAT TETHER

SPECIFICATIONS

PART LIST

3

OPERATION

This Pump should be plugged into an outlet fitted with a Ground Fault Circuit Interrupter (GFCI).

1. Make sure the Pump rests on a flat, level, and solid foundation.

2. Never suspend the pump from the power cord or discharge pipe. You may firmly attach a rope to the carry handle.

3. Keep the pump inlet openings, near the suction base, clear of debris.

4. Avoid installation in areas of extreme heat or cold.

5. If the piping you install runs in excess of ten feet, it is recommended you use a check valve (not included) to prevent back flow, which could lead to rapid cycling. To avoid air locks in the pump, drill a 1/8” hole, in the piping, between the check valve and the pump.

6. The sump pit must have a minimum diameter of 11” and maximum depth of 18 feet.

7.

Set the pump on a brick or block slightly smaller than the pit. Fill the pit with clean 1” stones to surround the lower half of the pump, and keep it stable. The stones should be large enough to not clog any of the inlets.

8. Test the pump.

9. Install a pump cover to protect the pump from dirt and falling debris.

OPERATION

WARNING: DO NOT let the pump run dry. It will increase wear to the unit and possible cause steel damage.

DO NOT try to turn the pump on manually after it has cut off. This pump has a built-in thermal protector for the motor, which will automatically shut off to avoid overheating. After it cools it will cycle back on.

1. Plug unit into an outlet fitted with a Ground Fault Circuit Interrupter (GFCI).

2. The pump will automatically turn on when the water level has filled to approximately 3” above the base.

It will stop when the water level drops below 3”. It will continue to recycle thereafter.

3. Check that the discharge water travels several feet from the foundation.

FLOAT SWITCH ADJUSTMENT

There is a Float Switch Lock that is part of the Rear Cover. The Switch cord snaps into the Float Switch

Lock. You can adjust the level that the Pump turns on by adjusting the length of the Float Switch cord.

NOTE: If air bubbles are spotted around the handle or pressure switch, this is normal. It is trapped air escaping from the unit. This pump is equipped with a de-aerating device which removes air locks in the pump. Also, if the water level drops below the Vent Valve, some water might purge from the pump from the

Vent Valve. This is normal. More on air escape covered in Troubleshooting.

ASSEMBLY

Hose Connection: The Universal Fitting connects to various hose sizes. The hoses should be connected using a step nipple (not included). In addition, the 1” and 1-1/4” hoses should also be secured with hose clamps (not included). The largest connection (1-1/2”) will yield the greatest flow. The top of the Universal

Fitting may be removed to fit on various size hoses. Use a knife to gently slide off any unneeded material.

NOTE: Use a pipe joint sealant to ensure air tight operation.

NOTE: (Optional) To reduce vibration and noise, a short section of rubber hose (1-1/4” x 1-3/8” ID) may be attached to the discharge line, using clamps (Hose and Clamps not included).

4

MAINTENANCE AND TROUBLESHOOTING

MAINTENANCE

PUMP MOTOR MAINTENANCE

1. Any repair or replacement of parts should be performed by a qualified service technician.

2. Inlets should be inspected periodically and any debris which clogs them should be removed (Before performing inlet cleaning, disconnect the pump from the outlet).

3. Periodically clean the Lower Base, remove the Screws from the Base and remove any dirt or debris.

Replace the Lower Base.

NOTE: Many problems occur due a clogged Lower Base. Remove the Screws from the Lower Base and remove the Lower Base. Clean out dirt or debris from the bottom of the Pump and replace Lower Base using the same screws.

TROUBLESHOOTING

5

WARRANTY

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY

DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR

DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT

HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS

QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR

DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE

UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER

ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL

PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION

OF REPLACEMENT PARTS THERETO.

Record Product’s Serial Number Here:

Note : If product has no serial number, record month and year of purchase instead.

Note : Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts.

PRODUCT MADE IN CHINA

6

advertisement

Related manuals

Frequently Answers and Questions

How often should the pump motor be maintained?
Periodically clean the Lower Base, remove the Screws from the Base and remove any dirt or debris. Replace the Lower Base.
What should be done to avoid the pump running dry?
Keep the pump inlet openings, near the suction base, clear of debris.
What is the minimum diameter and maximum depth of the sump pit?
The sump pit must have a minimum diameter of 11 inches and a maximum depth of 18 feet.
What is the purpose of the Float Switch Lock?
The Float Switch Lock is used to adjust the level that the Pump turns on by adjusting the length of the Float Switch cord.
How to prevent back flow in piping longer than ten feet?
If the piping you install runs in excess of ten feet, it is recommended you use a check valve (not included) to prevent back flow, which could lead to rapid cycling.