WarmlyYours TRT120-2.0x20 TemoZone 20 ft. x 24 in. 120-Volt Radiant Floor Heating Mat (Covers 40 sq. ft.) Installation Guide
Add to my manuals
2 Pages
WarmlyYours TRT120-2.0x20 is a programmable thermostat designed to control electric floor heating systems. It features a large, easy-to-read LCD display and intuitive menu navigation, making it simple to set and adjust temperatures. The thermostat also includes a built-in GFCI (ground fault circuit interrupter) for added safety, and it can be used with a variety of floor heating systems, including radiant floor heating, snow melting systems, and towel warmers.
With its advanced programming capabilities, the WarmlyYours TRT120-2.0x20 thermostat allows you to create customized heating schedules that meet your specific needs. You can program up to four daily events, each with its own temperature setting, and the thermostat will automatically adjust the temperature accordingly. The thermostat also features a built-in timer that can be used to turn the heating system on or off at specific times.
advertisement
WarmlyYours
TempZone
™
Easy Mats
TempZone™ Easy Mats allow for radiant heating of smaller, simpler areas at an affordable cost. Install radiant heating mats in front of your kitchen appliances and bath fixtures for a warm path of under floor heat where you stand the most.
We call this type of application “spot-heating” and it’s a very affordable option for incorporating floor heating into a smaller room like a bathroom. Utilizing the TempZone™ technology, Easy Mats are available in 120 volt systems. These under floor mats are perfect for providing targeted heating for moderately sized bathroom and kitchen floors or just the high traffic cooking areas of larger kitchens.
Installs under:
Tile Stone
Product Information
Easy Mat
Heating wire attached to an open cell type fiberglass mesh
Heating Element
Color
Heating Element
Insulation
Heating Cable
Outer Insulation
Blue
Fluoropolymer
Fluoropolymer
Heating Output 15 watts per sq. ft.
Certifications
UL listed for wet locations like shower floors and benches
Warranty
Example Project
25-year No Nonsense™ Warranty
Heated Area
Product Cost
3’ x 6’
$234.00 USD
$292.50 CAD
Bathroom
3’ x 8’
$276.00 USD
$345.00 CAD
3’ x 10’
$300.00 USD
$375.00 CAD
Hourly Cost*
1¢/hr USD
2¢/hr CAD
2¢/hr USD
2¢/hr CAD
2¢/hr USD
3¢/hr CAD
* Based on national average of 12¢ per kWh (USA) and 14¢ per kWh (Canada)
Engineered Wood &
Laminate
Dimensions
Heating Element
Thickness
Cold Lead
Information
LVT
Variable, nominal 1/8”
•
Length: 15’
•
17 AWG for mats of
9 amps or less
•
1/2” Conduit
2 Cold Leads Max
•
3/4” Conduit - 3 Cold Leads
Install per local code requirements
Factory Splice
Max Size
.4”, 13/32”, 10.3mm
Electrical
TempZone Easy Mats have no polarity.
WarmlyYours controls are equipped with ground fault circuit interrupter (G.F.C.I.) protection.
Voltage
Cold Lead
Construction
Cold Lead
Wire Colors
Available in 120V
Style number AWM2095, 2 core wires, screened with ground
120V: Yellow & black with black outer sheath
4 Simple Steps to Install
1
Layout TempZone™ Easy
Mats according to your custom SmartPlan™
2
Secure the Included
Floor Sensor
Installation Information
•
Heating element should be embedded within a
minimum 3/8” thick layer of modified thinset or self-
leveling underlayment.
•
Heating element should be installed within 1” to 1.5”
from the top of the flooring surface.
•
Multiple Easy Mats can be wired to a control, as
long as they total less than 15 amps (the limit of the
controller).
•
Multiple Easy Mats are never wired to each other in
series (parallel wiring required). The non-heating
leads from each Easy Mat need to hook up to the
controller and be wired in parallel.
•
Do not install under permanent fixtures.
•
Do not install within 4” of the toilet wax ring.
•
Entire heating section and splices need to be
embedded in thinset or self-leveling underlayment
to prevent overheating and premature failure.
•
Do not shorten the warming mat. Do NOT cut the
heating wire. Only the non-heating cold leads can
be shortened.
•
Do not run a power lead or sensor wire across a
warming cable.
3
Apply Thinset or SLC (3/5” thick minimum)
4
Install
Flooring
•
Do not fold or position the warming system so that the
mesh overlaps itself or other warming cables (this could
lead to dangerous overheating).
•
Do not connect the warming mat to the power supply for
testing before it is embedded (this could lead to
dangerous overheating). Testing is only done with a
digital ohm meter.
•
120 sq. ft. of heating can be installed on a single 120 V
circuit.
•
TempZone Easy Mats should be installed with a floor
sensor. All WarmlyYours nSpiration Series thermostats
come with a floor sensor.
How to Order
1 Simply draw a floor plan sketch of your project
(including dimensions) .
2 Send it to [email protected]
. Then
WarmlyYours’s skilled engineers will create a free
SmartPlan™ custom installation plan based on your drawing, typically in as little as 1 business day.
3 After you receive your SmartPlan™, just verify the correct dimensions before placing your order with your WarmlyYours account manager.
Draw a floor plan of your project and we’ll do the rest!
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement