ELF DSX User Manual


Add to my manuals
28 Pages

advertisement

ELF DSX User Manual | Manualzz

®

®

ELF DSX

USER MANUAL

124317-5 A0

ELF DSX User Manual

Document Number 124317-5 A0

Copyright© 2001, Telect, Inc., All Rights Reserved.

Telect® and Connecting the Future® are registered trademarks of Telect, Inc., 2111 N. Molter Rd., Liberty Lake,

Washington 99019

Technical Support (USA):

By e-mail: [email protected]

By phone: 888-821-4856 or 509-921-6161

Note:

Telect assumes no liability from the application or use of these products. Neither does Telect convey any license under its patent rights nor the patent rights of others. This document and the products described herein are subject to change without notice.

ii

Telect, Inc.

124317-5 A0

Contents

124317-5 A0

1 Descriptions

ELF DSX ..................................................................................... 1-1

Capabilities ............................................................................ 1-2

Features .................................................................................. 1-2

Part Numbers ......................................................................... 1-2

System-Level Applications.......................................................... 1-2

Main Assemblies.......................................................................... 1-3

Rack-Mount Systems ............................................................. 1-3

Wall-Mount Systems ............................................................. 1-3

Specifications ............................................................................... 1-4

Electrical ............................................................................... 1-4

Physical ................................................................................. 1-5

2 Installation

Installation Considerations .......................................................... 2-1

Location and Space ................................................................ 2-1

Tools and Equipment ............................................................. 2-2

Technical Support (USA) ...................................................... 2-2

Inspection..................................................................................... 2-2

Installation Procedure for Rack-Mount ELF DSX ...................... 2-3

Rack-Mount Options.............................................................. 2-3

Rack Mounting and Cabling Procedure ................................. 2-3

Installation Procedure for Wall-Mount ELF DSX ....................... 2-5

3 Electrical Operation

Schematic, Rack-Mounted Wire-Wrap ........................................ 3-1

Schematic, Rack-Mounted BNC.................................................. 3-2

Schematic, TFA Wire-Wrap......................................................... 3-2

Schematic, Rack-Mounted RJ-48C.............................................. 3-3

Schematic, TFA RJ-48C .............................................................. 3-3

®

®

iii

4 User Functions

Monitoring ................................................................................... 4-1

Patch And Roll............................................................................. 4-1

5 Service

Owner Maintenance ..................................................................... 5-1

In Case Of Difficulty ................................................................... 5-1

Technical Support (USA) ...................................................... 5-1

In-Warranty Service ..................................................................... 5-2

Out-Of-Warranty Service............................................................. 5-2

Repacking For Shipment ............................................................. 5-2

iv

Telect, Inc.

124317-5 A0

1

Descriptions

ELF DSX

Telect’s ELF DSX serves as a small, “edge” connection device in locations where equipment density is important.

®

®

1-1

124317-5 A0

1 Descriptions ELF DSX User Manual

Capabilities

• Expandable system—up to three ELF modules per chassis

• T1/E1 signal rates

Features

Telect’s T1/E1 low-profile front cross connect (FXC) rack- and wall-mount

ELF panels are designed to fit on the edge of a 3G wireless network, at the base transceiver station (BTS). The panel’s compact front access allows maximum density and simplified monitoring.

• Wire-wrap, BNC I/O, or RJ-48C connections.

• Front cross-connect, including a shield ground pin for ITU G.703 compiance.

• Universal rack mount—19" (48.3 cm) or 23" (58.4 cm), using 1 EIA rack unit (RU) of space. Also mounts in an equipment cabinet.

• Total Front Access (TFA) versions can be mounted in the standard ELF chassis or in an optional wall bracket.

Part Numbers

• ELF-1008-1100 8-termination module, wire-wrap I/O

• ELF-1008-1200 8-termination module, BNC I/O

• ELF-1008-1800 8-termination module, RJ-48C

• ELF-3006-1100 6-termination module, wire-wrap TFA

• ELF-3006-1800 6-termination module, RJ-48C TFA

• ELF-0000-2400 3-module chassis for all ELF modules

• ELF-0000-0600 Wall bracket for ELF-3008-1100 & ELF-3006-1800

• ELF-0005-0001 12 x 4 Alarm Pin Block

S

YSTEM

-L

EVEL

A

PPLICATIONS

• Wireless base transceiver station (BTS)

• Customer premises

• Controlled environment vault

• Co-location

1-2

Telect, Inc.

124317-5 A0

ELF DSX User Manual

M

AIN

A

SSEMBLIES

Rack Mount Systems

The chassis holds up to three

8-termination modules, 6terminal-TFA modules, or

12x4 alarm pin blocks for an expandable system. The backplanes of 8-termination modules hold either wirewrap pins, BNC connectors, or RJ-48C connectors for

I/O connections.

1 Descriptions

Ground

Stud

Cable

Tie-Down

Bar

Chassis Backplane, Wire-Wrap

Ground

Stud

Cable

Tie-Down

Bar

Chassis Backplane, BNC

8

7

6

5 3

4 2

1

8

7 5

6 4

3

2

1

Chassis Backplane, RJ-48C

8

7

6

5

4

3 1

2

Ground

Stud

Cable

Tie-Down

Bar

Wall-Mount Systems

The optional wall-mounted bracket holds one 6-termination, total front ac-

®

cess (TFA I/O & X-CON) wire-wrap or a 12 x 4 alarm pin block.

®

124317-5 A0

1-3

1 Descriptions ELF DSX User Manual

S

PECIFICATIONS

Electrical

Return Loss

Interchannel Crosstalk

Adjacent Channel Crosstalk

Insertion Loss

Monitor Level

E1

12 dB 51 kHz to 102 kHz

18 dB 102 kHz to 2048 kHZ

14 dB 2048 kHz to 3073 kHz

-60 dB at bit rate (2.048 Mbps)

-60 dB at bit rate (2.048 Mbps)

0.5 dB at bit rate (2.048 Mbps)

–20 dB ± 1.5 dB at bit rate

(2.048 Mbps)

26 dB 772 kHz

T1

-60 dB at bit rate (1.544 Mbps)

-60 dB at bit rate (1.544 Mbps)

0.5 dB at bit rate (1.544 Mbps)

–20 dB ± 1.5 dB at bit rate

(1.544 Mbps)

1-4

Telect, Inc.

124317-5 A0

ELF DSX User Manual

Physical

1.75 in.

(4.4 cm)

19 in.

(48.3 cm)

1 Descriptions

Rack Mount

5.5 in.

(14.0 cm)

3.5 in.

(8.9 cm)

124317-5 A0

®

®

1-5

1 Descriptions ELF DSX User Manual

1-6

Telect, Inc.

124317-5 A0

2

Installation

I

NSTALLATION

C

ONSIDERATIONS

!

CAUTION

CAUTION! This product must be installed and maintained only by qualified technicians.

VORSICHT! Nur von qualifizierten Technikern installiert werden und instand gehalten werden.

PRECAUCIÓN! Ser instalado y ser mantenido solamente por los técnicos autorizados.

ATTENTION! Ce produit doit être installé et entretenu uniquement par des techniciens qualifiés.

!

ALERT

ALERT! These instructions presume you have verified that the

Telect equipment being installed is compatible with the rest of the system, including power, ground, circuit protection, signal characteristics, equipment from other vendors, and local codes or ordinances.

Location and Space

124317-5 A0

• The ELF DSX chassis mounts in a 19" (48.3 cm) or 23" (58.4 cm)

EIA rack, it takes up one RU of space (1.75"/4.4 cm).

• The ELF DSX wall bracket requires 6" (15.2 cm) by 1.8" (4.5 cm) of

®

wall space.

2-1

2 Installation ELF DSX User Manual

Tools and Equipment

• Standard and wire-wrap tools

• A chassis ground wire—14 AWG minimum with ring terminal.

Use listed components (UL-recognized, CSA, ETL, TUV agency) and crimping tools.

Technical Support (USA)

By e-mail: [email protected]

By phone: 888-821-4856 or 509-921-6161

I

NSPECTION

Compare the contents of the ELF DSX shipping container with the packing list. Call Telect if you are missing anything.

NOTE

Telect is not liable for shipping damage.

If the shipping container is damaged, keep it for the carrier’s inspection.

Notify the carrier and call Telect’s Customer Service Department:

1-800-551-4567 or 1-509-926-6000

Keep the container until you have checked equipment operation. If you experience any kind of problem, call Telect’s Customer Service Department.

Use the original, undamaged container if you are instructed to return the

ELF DSX to Telect.

2-2

Telect, Inc.

124317-5 A0

ELF DSX User Manual 2 Installation

I

NSTALLATION

P

ROCEDURE

F

OR

R

ACK

-M

OUNT

ELF DSX

Rack-Mount Options

You can leave the mounting brackets in their default location on the chassis for 19" (48.3 cm) flush mounting. Or you can remove and reposition the brackets for a number of different mounting options:

(1)

19" Orientation

(End Views)

23" Orientation

(2)

(3)

Bracket Position

1A

1B

2A

2B

3A

3B

Mount Option

Flush

Extended

Recessed

Recessed*

Flush

Extended

*The recess is very slight at this

position, almost flush.

(A) (B)

ELF DNX, Right-End View

ELF DSX, Right-End View

Rack Mounting and Cabling Procedure

124317-5 A0

2.

3.

Step Action

1.

Insert one to three ELF DSX modules into the chassis. Secure each module to the chassis faceplate with two screws (provided).

Mount the ELF DSX with four screws (#12 or M6, both sets are provided).

®

Attach a 14 AWG ground wire with a ring lug to the 8-32 ground stud on the rear panel. Connect the opposite end to a ground point on the rack.

®

2-3

2 Installation ELF DSX User Manual

2-4

4.

5.

Attach in/out (I/O) cables (at the rear for chassis systems; at the front for TFA DSX modules used in chassis). Connectors are labeled. Use cable ties and the tie-down bar to manage the cables.

Make cross-connects at the front of the panel. If required, secure jumpers to the front tie-down bar using cable ties inserted through the slots in the bar and then wrap the tie around the jumpers.

Wire Wrap

A TO B IS EXAMPLE ONLY

A B A B

T

OUT

R

Out T “A” to In T “B”

Out R “A” to In R “B”

In T “A” to Out T “B”

In R “A” to Out R “B”

SG to SG (E1)

JUMPER ROUTING SCHEME

BETWEEN PINS SHOWN HERE

IS EXAMPLE ONLY

IN

T

R

SG

Tie-Down Bar

Cable Tie

T

R

OUT

T

R

IN

SG

Telect, Inc.

124317-5 A0

ELF DSX User Manual

RJ-48C

2 Installation

6.

NOTE

There are no LEDs and therefore no tracer lamp (TL) connections to make. A shield ground cross-connect pin is provided for crossconnecting shield ground with the drain wire.

Record the circuits on the front designation card.

I

NSTALLATION

P

ROCEDURE

F

OR

W

ALL

-M

OUNT

ELF DSX

TFA ELF Module

124317-5 A0

Wall Bracket

®

®

2-5

2 Installation ELF DSX User Manual

Step Action

1.

2.

3.

Use four, suitable panhead screws to secure DSX bracket to wall.

Screws are not included.

Mount the ELF DSX in bracket using two M3 screws provided.

The away-facing surfaces of the mounting ears on the module are stripped of paint to ensure a good electrical ground. For grounding, use the ring lug and star lockwasher provided along with a #14

AWG (min.) copper wire.

For TFA Wire-Wrap DSX modules, a. Wire-wrap in/out (I/O) cables to the left of the patch area. Use cable ties and the tie-down bar to manage cables.

b. Make cross-connects at the right of the patch area. Again, use cable ties and tie-down bar to manage cables.

The example below shows network element 1 (NE 1) cross-connected to NE 6.

2-6

Telect, Inc.

124317-5 A0

ELF DSX User Manual

4.

2 Installation

NOTE

There are no LEDs and therefore no tracer lamp (TL) connections to make. A shield ground cross-connect pin is provided for cross-connecting shield ground with the drain wire.

c. Record the circuits on the designation card and affix anywhere.

For TFA RJ-48C DSX modules, make input/output (I/O) interconnections along the bottom row of RJ connectors and cross connections along the top row, as shown in the following illustration.

Record the circuits on the designation card and affix anywhere.

124317-5 A0

®

®

2-7

2 Installation ELF DSX User Manual

2-8

Telect, Inc.

124317-5 A0

3

Electrical Operation

S

CHEMATIC

, R

ACK

-M

OUNTED

W

IRE

-W

RAP

MON

R

OUT

IN

T

R

T

R

Out

In

SGnd

Equipment I/O

Front

Cross-Connect

Out

In

T

R

T

R

SGnd

Shield Gnd

®

®

3-1

124317-5 A0

3 Electrical Operation

S

CHEMATIC

, R

ACK

-M

OUNTED

BNC

MON

R

OUT

IN

Front

Cross-Connect

Out

In

T

R

T

R

SGnd

Shield Gnd

120/75

ELF DSX User Manual

XFR

OUT

IN

0

S

CHEMATIC

, TFA W

IRE

-W

RAP

R2

R1

3-2

MON

OUT

IN

Front

Cross-Connect

OUT

IN

S. GND.

T

R

T

R

T

R

OUT

T

R

IN

S. GND.

Front

Input/Output

Telect, Inc.

124317-5 A0

ELF DSX User Manual

S

CHEMATIC

, R

ACK

-M

OUNTED

RJ-48C

R2

R1

MON

OUT

IN

X-CON

OUT

IN

S. GND.

T

R

T

R

3 Electrical Operation

S. GND.

IN

OUT

T

R

T

R

2

1

4

3

8

7

6

5

I/O

S

CHEMATIC

, TFA RJ-48C

R2

R1

MON

124317-5 A0

OUT

IN

X-CON

1

2

3

4

5

6

7

8

R

T

R

T

OUT

IN

RJ SHIELD GND.

CHASSIS GND.

IN

OUT

8

T

5

R 4

7

6

3

T 2

R 1

I/O

®

®

3-3

3 Electrical Operation ELF DSX User Manual

3-4

Telect, Inc.

124317-5 A0

4

User Functions

M

ONITORING

To monitor the OUT signal from an ELF DSX module, plug one end of a single patch cord into the MON port and the other end into the monitoring equipment. The MON port connection is nonintrusive.

P

ATCH

A

ND

R

OLL

Patching maintains a circuit by temporarily cross-connecting to back-up equipment so that technicians can repair or test the lines of the permanent connection. Patching and rolling allows a circuit to be moved from an existing facility to a new or spare facility, including new permanent crossconnects.

NOTE

If you use a dual patch plug, remember to twist the plug on one end of the cord so that it is reversed (i.e., turned upside down) from the other end.

124317-5 A0

Step Action

1.

2.

Patch B to spare facility C. Insert patch cords in C, then in B.

Remove the cross connects between the A and B facilities.

®

®

4-1

4 User Functions ELF DSX User Manual

O

I

O

I

3.

4.

M

A

M

O

I

Install cross-connects between B and C.

Remove the patch cords between B and C. Service is established through the new cross-connects.

B

Patch

C

NOTE:

CROSS-CONNECTS ARE SHOWN

IN DIAGRAM FORM.

M

O

I

OUT

IN

T

R

T

R

SG

A

Cross-Connect

(E1)

B

T

R

T

R

SG

OUT

IN

1

M

A

M

B C

O

I

Patch

M

O

I

OUT

IN

T

R

T

R

SG

A

2

B

T

R

T

R

SG

OUT

IN

M

A

M

B

O

I

O

I

4

C

M

O

I

OUT

IN

T

R

T

R

SG

B

3

(E1)

C

T

R

T

R

SG

OUT

IN

4-2

Telect, Inc.

124317-5 A0

5

Service

!

CAUTION

CAUTION! This product must be installed and maintained only by qualified technicians.

VORSICHT! Nur von qualifizierten Technikern installiert werden und instand gehalten werden.

PRECAUCIÓN! Ser instalado y ser mantenido solamente por los técnicos autorizados.

ATTENTION! Ce produit doit être installé et entretenu uniquement par des techniciens qualifiés.

O

WNER

M

AINTENANCE

Telect’s ELF DSX does not need preventive maintenance.

I

N

C

ASE

O

F

D

IFFICULTY

If problems occur after initial installation, check cable connections and grounding as described in the installation instructions in Chapter 2.

Technical Support (USA)

By e-mail: [email protected]

By phone: 888-821-4856 or 509-921-6161

®

®

124317-5 A0

5-1

5 Service ELF DSX User Manual

I

N

-W

ARRANTY

S

ERVICE

Contact your Telect equipment distributor, or call a Telect Customer Service Representative:

1-800-551-4567

1-509-926-6000

Telect will repair or replace defective products within the limits of the warranty. See “Repacking for Shipment” in this section.

NOTE

Call a Customer Service Representative for a Return Material Authorization (RMA) before returning any equipment.

O

UT

-O

F

-W

ARRANTY

S

ERVICE

The procedure for out-of-warranty service is the same as for in-warranty service, except that Telect charges a processing fee, and you must submit a

Purchase Order along with a Return Material Authorization (RMA) before returning equipment. Call a Customer Service Representative for help getting these forms.

The processing fee guarantees a repair estimate and is credited against actual material and labor costs.

R

EPACKING

F

OR

S

HIPMENT

5-2

1.

2.

Step Action

3.

Tag the equipment showing owner’s name, address, and telephone number, together with a detailed description of the problem.

Use the original shipping container if possible. If you do not have it, package the equipment in a way to prevent shipping damage. Include the RMA inside the container and legibly print the RMA number on the outside of the package, near the shipping address.

Insure the package.

NOTE

Telect is not liable for shipping damage.

Telect, Inc.

124317-5 A0

Telect, Inc.

2111 N. Molter Rd.

P.O. Box 665, Liberty Lake, WA 99019

509-926-6000, 800-551-4567, Fax 509-926-8915

E-mail: [email protected] Internet: http://www.telect.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals