BFT KUSTOS BTA Manual
Annonce
Annonce
1
Cable run
Use normalised black cables
R02V - HO5V VF
KUSTOS BTA
FW ≥ 2.05
2
Motor fastening
x S
D
F
2s
3x1.5 mm²
2x0.75 mm²
3x1.5 mm²
5x0.75 mm²
3x1.5 mm² 230 v
3
Limit switch adjustment (put motor in gear by moving the panel by hand)
2 2
FERME OUVRE
1 1
P a
C=1190mm
S
(mm)
20
30
40
KUST OS BT A40
125 kg (~ 1250 N) b (mm)
250 kg
130 ÷ 160
130 ÷ 170
130 ÷ 180
(~ 2500 N)
170 ÷ 260
180 ÷ 260
190 ÷ 260 b a 100 110 120
1 0 0
110
120
130 140 15 0 160 170 180 190 200 210 220
1 1 7 1 2 0 1 2 3 1 2 6 1 1 9 1 1 3 1 0 8 1 0 4
112 116 119 121 122 116 110 10 5 102
107 110 114 117 120 117 111 106 102
1 0 1
130 103 106 109 113 116 117 113 107 102
140 97 102 10 5 108 112 11 5 113 110 103
15 0 97 101 104 107 110 113 110 104
160 97 100 104 107 109 110 105
170 96 100 103 106 108 105
180 96 100 103 106 107
190 96 99 102 105
200 96 98 101
210 9 5 98
220 95 kg
a
Cu MAX
KUST OS BT A40 a
1210
Cu Max
355
4
Programming (see reverse)
Adjust the limit switches and the stops according to the diagrams, open/closed position.
If necessary, fine-tune the adjustments to be performed upon completion of installation.
For safety warnings, please see complete instruction manual
Zara Control board
P W R O N
JP4
1
3
T1
+
T2
+
T3
+
T4
+
SHIELD
ANT
F2 4 AT
2
ZARA
ON
1
L N 10 11 14 15 20 21 28 29 40 41 42 43 44 45 50 51 52 60 61 62 70 71 72 73 74 75
24V - 24V + 24 VSafe+ COM
-
M1 M2
2
OFF
KEYS
S1
S2
S2
>5s
S3
L N
Motor Blinker
Solenoid lock
Limit switch
inputs
DIP Function
2
3
1
4
5
6
7
8
9
10
Transmitter programming
Selection of sensing bars.
Check photocells.
Secure entry check.
Photocells during closing
Safety edge input operation
Rapid closure.
Residential / apartment building operation
Hammer during opening
Closing limit switch pressure
ON: Memorise the commands/copy via remote controls already recorded.
OFF : Disables memorizing of transmitters
ON : Input for resistive edge 8K2.
OFF: Entry for sensitive lintel.
ON : Enable safety check
OFF: Deactivate the cell check.
ON : Enable safety check
OFF: Deactivate the sensing check.
ON: Invert the movement during the closure phase only.
OFF: Active on opening and closing; invert the movement during the closure phase.
ON : Safety edge with active reversal only when closing, when opening the movement stops
OFF : Safety edge with active reversal in both directions
ON : Closes 3 seconds after the photocells are cleared
OFF: Rapid closure deactivated.
Sets the automation type of operation:
ON = Apartment building
OFF = Residential
ON : Before opening completely, the gate pushes for approx. 2 seconds as it closes.
This allows the solenoid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
OFF : Logic not enabled
ON : Use when there is a mechanical stop in closed position.This function allows leaves to press against the mechanical stop without the Amperostop sensor interpreting this as an obstacle. Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as the mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the closing limit switches to trip slightly earlier.
OFF : Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing limit switch must be adjusted accurately
Description
Add Start Key associates the desired key with the Start command.
Add Pedestrian Key associates the desired key with the pedestrian command.
Confirms the changes made to parameter settings and operating
Erase List
WARNING! Erases all memorized transmitters from the receiver’s memory.
Pressed BRIEFLY, it gives the START command.
HELD DOWN (>5 sec.), it activates the AUTOSET function.
2
Accessories power supply
Commands Safety devices
3
TRIMMER Function
T1
T2
T3
T4
Waiting time before automatic closing.
% Force exerted by leaf
% Slow-down speed
Motor 1 closing delay time [s]
Reaction to the START input (wired or radio):
CLOSED
WHILE
CLOSING
Residential
Opens
Stops
Apartment building
Opens
Opens
Closes Closes OPEN
WHILE
OPENING
AFTER
STOP
STOPS+TCA No effect
Opens Opens
Reaction to the OPEN input (wired):
Residential
Apartment building
Opens CLOSED Opens
WHILE
CLOSING
Opens
OPEN
WHILE
OPENING
No effect
Keeps it open
AFTER
STOP
Opens
Opens
No effect
Keeps it open
Opens
Reaction to the PEDESTRIAN input (radio):
Residential
CLOSED Opens partially
WHILE
CLOSING
Stops
Closes OPEN
WHILE
OPENING
Apartment building
Opens partially
Opens partially
Closes
STOPS+TCA No effect
AFTER
STOP
Opens partially
Opens partially mini.
+
0
10
5
0
1
120
100
50
25
1
Testing the direction of opening - running / stop: apply power, motor engaged and at stroke centre.
Checking the direction of rotation. I press S3, my two motors must open.
START S3 X1
START
S3
STOP
If they close, switch wiring: M1 : 10&11 / M2 : 14&15
X1
Left Right
M1 closes second.
2 How to programme the remote control
START
S1 S2 S3 x1
S1
LED RADIO
FLASHES
RADIO
Press the 2 top keys simultaneously
(hidden key). The LED remains fixed
S1
Choose the key
S1
LED RADIO
FLASHES
OK
3 Start an autoset, gate closed.
S1 S S3
5s
=
S1 S2 S3
SET
AUTO OPEN AUTO CLOSE
AUTO OPEN AUTO CLOSE
OK
S1 S2 S3
SET
S1 S2 S3
KO
SET
4 How to perform an open/close test by using the remote control.
5
Wire the THEA photocells.
50 51 52
DIP3=ON
70 72 73
6 Wire the DESME photocells.
50 51 52
DIP3=OFF
70 72
1
2
TX1 RX1
1
2
3
4
5
1
2
TX1
6 Fine-tune the adjustments. Motor functions using the potentiometers (T1, T2, T3, T4).
RX1
1
2
3
4
5
Remember to check by pressing S2 for 5 sec.
+ + +
4
+ mini maxi
1 - I wish to deactivate the photocells during opening:
2 - I wish to activate and adjust automatic closure:
3 - I wish to activate pedestrian opening:
As an option, to go further....
4 - I wish to adjust the time difference between M1 & M2:
Place dipswitch 5 in the ON position.
This is done by regulating the T1 potentiometer.
Please refer to the remote control programming by pressing S2.
This is done by regulating the T4 potentiometer.
2