Реклама
Реклама
2021 | INDUSTRIAL VENTILATION
Tower-H
Roof centrifugal fans
Use
Extract ventilation systems installed in various premises.
Roof mounting.
For any types of roofs or vertical ventilation shafts.
Air flow: up to from
17
Power:
48
010
4725
W
m³/h
l/s
Noise level: from 45 dBA
Design
Steel casing with a special polymer atmospheric resistant coating.
Horizontal air exhaust.
The fan is equipped with a terminal block for connection to power mains.
The fan is rated for continuous operation.
Impeller with a protecting insect screen.
The upper cover is equipped with two eye bolts for easy fan lifting on the roof with hoisting mechanism.
A connecting plate with an intake opening is designed to facilitate mounting to the roof surface.
Motor
Two-, four- or six-pole asynchronous motor with external rotor and centrifugal impeller with backward curved blades.
Single-phase ( E ) or three-phase ( D ) motor modifications.
Dynamically balanced impeller.
Equipped with ball bearings for longer service life.
Overheating protection by built-in thermal switches with leaded outside terminals for connection to external protecting controls.
The thermal switch terminal leads are designed for connection to respective circuit of the overload relay or respective terminals of the autotransformer or thyristor speed controller.
Speed control
Smooth or step speed control with a thyristor or transformer speed controller
(available upon order).
Mounting
Roof mounting directly above a ventilation shaft or air duct.
The fan is connected to the air duct with the intake flange that is fixed to the fan base.
The fan base has holes for fixing bolts that attach the fan to the stable level surface or a roof frame.
Roof frame and intake flange available on separate order.
Power is supplied through an external terminal box.
Designation key
Series Impeller standard size
Tower-H 220; 225; 250; 280; 310; 355; 400; 450; 500
Accessories
Flexible connectors for roof fans
Counterflanges Mounting frames
Motor
Number of poles
2; 4; 6
Silencers
Phase
E: single-phase
D: three-phase
Casing material
_: steel with polymeric coating
A: aluminum
Backdraft air dampers
Air dampers Speed controllers
208
VDL FDL MRDL / MRIDL SD VRV VK / VKA CDT E1.8
blaubergventilatoren.de
blaubergventilatoren.de
Overall dimensions
[mm]
Type
Tower-H 190 2E
Tower-H 220 2E
Tower-H 225 2E
Tower-H 225 4E
Tower-H 250 2E
Tower-H 250 4E
Tower-H 280 4E
Tower-H 310 2E
Tower-H 310 4E
Tower-H 310 4D
Tower-H 355 4E
Tower-H 355 4D
Tower-H 400 4E
Tower-H 400 6E
Tower-H 400 4D
Tower-H 450 4E
Tower-H 450 6E
Tower-H 450 4D
Tower-H 500 6E
Tower-H 500 4D
Tower-H 500 6D
Tower-H 560 6E
Tower-H 560 4D
Tower-H 560 6D
Tower-H 630 6D
Tower-H 710 6D
øD
438
438
438
438
285
285
438
438
285
285
291
291
213
213
210
210
445
605
605
605
438
438
445
430
600
674
H
376
376
376
420
287
287
322
347
237
237
265
251
189
180
210
233
461
489
489
489
420
420
461
490
520
570
L
L
625
625
625
710
451
451
625
625
451
451
451
451
351
337
351
351
710
900
900
900
710
710
710
710
1000
1060
H1
415
415
415
459
294
294
361
386
244
244
272
258
195
186
217
240
501
528
528
528
459
459
501
530
560
619
L1
620
620
620
700
450
450
620
620
450
450
450
450
350
338
350
350
700
895
895
895
700
700
700
700
990
1050
Weight [kg]
35
32.7
35
46.6
14.2
14.2
28.3
30.3
12.7
12.1
13.5
13.2
8.2
7
9.2
8.8
52.7
76.4
81.4
76.4
45.6
45.5
52.8
46.6
96.3
134
∅ D
INDUSTRIAL VENTILATION | 2021 209
2021 | INDUSTRIAL VENTILATION
Technical data
Parameters
Voltage [V]
Frequency [Hz]
Power [W]
Current [A]
Maximum air flow [m³/h (l/s)]
RPM [min⁻¹]
Sound pressure at 3 m [dBA]
Max. transported air temperature [°C]
SEC class
IP rating
Motor IP rating
ErP
Tower-H 190 2E
1~230
50
69
0.30
610 (169)
2680
48
-25…+50
60
89
0.40
654 (182)
2980
49
C –
IPX4
IP44
2018 –
TOWER-H 190 2E
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
L wA
to inlet [dBA]
L wA
to environment [dBA]
68
69
39 65 63 54 52
28 50 61 64 63
49 49
62 54
39
41
47 57
48 58
500
0
450
400
350
300
250
200
150
100
50
0
0
25 50 75 100 125
Air flow [l/s]
150 175
100 200
75
300 400 500 600 700
Air flow [m 3 /h]
Air flow [l/s]
100 125 150 175
120
0
80
40
0
0
25 50
100 200 300 400 500 600 700
Air flow [m 3 /h]
TOWER-H 225 2E
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
L wA
to inlet [dBA]
L wA
to environment [dBA]
71
72
61 66 66 62 57
47 59 67 66 67
57 55
57 52
48
42
51 61
51 61
50 100 150 200 250
Air flow [l/s]
300
700
0
600
500
400
300
200
100
0
0 200 400
50 100 150
600
200
800 1000 1200
Air flow [m 3 /h]
250
Air flow [l/s]
300
200
150
100
50
0
0
0 200 400 600 800 1000
3
1200
Tower-H 220 2E
1~230
50
108
0.49
880 (244)
2580
50
-25…+50
60
118
0.54
883 (245)
2840
51
C –
IPX4
IP44
2018 –
Tower-H 225 2E
1~230
50
123
0.54
915 (254)
2790
51
-25…+50
60
169
0.70
1010 (281)
2820
52
C –
IPX4
IP44
2018 –
Tower-H 225 4E
1~230
50
49
0.22
738 (205)
1400
45
-25…+50
C
IPX4
IP44
2018
TOWER-H 220 2E
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
L wA
to inlet [dBA]
L wA
to environment [dBA]
70
71
59 65 65 61 55 55
46 58 66 65 66 56
54 47
51 41
49 59
50 60
600
Air flow [l/s]
0 25 50 75 100 125 150 175 200 225 250
500
400
300
200
100
0
0 100 200 300 400 500 600 700 800 900
Air flow [m 3 /h]
Air flow [l/s]
25 50 75 100 125 150 175 200 225 250
160
0
120
80
40
0
0 100 200 300 400 500 600 700 800 900
Air flow [m 3 /h]
210 blaubergventilatoren.de
blaubergventilatoren.de
Parameters
Voltage [V]
Frequency [Hz]
Power [W]
Current [A]
Maximum air flow [m³/h (l/s)]
RPM [min⁻¹]
Sound pressure at 3 m [dBA]
Max. transported air temperature [°C]
SEC class
IP rating
Motor IP rating
ErP
50
184
0.81
1450 (403)
2480
54
Tower-H 250 2E
1~230
60
232
0.90
1320 (367)
2320
53
-25…+50
–
IPX4
IP44
2018 –
TOWER-H 250 2E, TOWER-H 250 4E
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
Tower-H 250 2E
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 250 4E
L wA
to inlet [dBA]
L wA
to environment [dBA]
75
75
68
67
50 63 70 68 69
51 64 71 67 67
51 57 60 52 63
29 48 57 60 63
66
66
62
59
63
62
57
51
53
56
Air flow [l/s]
50 100 150 200 250 300 350 400
52
37
700
0
600
500
400
54 64
54 64
47 57
46 56
300
200
100
0
0 250 500 750 1000 1250 1500
Air flow [m 3 /h]
Air flow [l/s]
50 100 150 200 250 300 350 400
300
0
200
100
0
0 250 500 750 1000 1250 1500
Air flow [m 3 /h]
Tower-H 250 4E
1~230
50
48
0.23
820 (228)
1440
46
-25…+50
–
IPX4
IP44
2018
50
125
0.61
1490 (414)
1446
46
Tower-H 280 4E
1~230
60
155
0.99
1520 (422)
1710
46
-25…+50
–
IPX4
IP44
2018 –
TOWER-H 280 4E
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
L wA
to inlet [dBA]
L wA
to environment [dBA]
66
67
46 55 53 59 60
29 48 57 60 63
59
59
55 45
51 37
45 55
46 56
600
0
Air flow [l/s]
50 100 150 200 250 300 350 400 450
500
400
300
200
100
0
0 250 500 750 1000 1250 1500 1750
Air flow [m 3 /h]
Air flow [l/s]
50 100 150 200 250 300 350 400 450
300
0
200
100
0
0 250 500 750 1000 1250 1500 1750
Air flow [m 3 /h]
INDUSTRIAL VENTILATION | 2021 211
2021 | INDUSTRIAL VENTILATION
Parameters
Voltage [V]
Frequency [Hz]
Power [W]
Current [A]
Maximum air flow [m³/h (l/s)]
RPM [min⁻¹]
Sound pressure at 3 m [dBA]
Max. transported air temperature [°C]
IP rating
Motor IP rating
ErP
Tower-H 310 2E
1~230
50
324
1.42
2150 (597)
2620
58
-25…+50
IPX4
IP44
2018
Tower-H 310 4E Tower-H 310 4D Tower-H 355 4E Tower-H 355 4D
1~230 3~400 1~230 3~400
50
141
60
195
50
155
60
202
50
219
60
304
50
264
60
330
0.64
0.87
0.29
0.32
0.96
1.33
0.58
0.64
2265 (629) 2425 (674) 2300 (639) 2442 (678) 2480 (689) 2976 (827) 3290 (914) 3540 (983)
1420
47
1740
49
1410
47
1550
48
1420
51
1580
52
1430
52
1650
53
-25…+50
IPX4
IP54
-25…+50
IPX4
IP54
-25…+50
IPX4
IP54
-30…+60
IPX4
IP54
2018 – 2018 – 2018 – 2018 –
TOWER-H 310 2E, TOWER-H 310 4E, TOWER-H 310 4D
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
Tower-H 310 2E
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 310 4E
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 310 4D
L wA
to inlet [dBA]
L wA
to environment [dBA]
76
79
67
68
67
67
47 48 56 69 71
40 48 62 73 74
47 56 54 61 62
30 49 58 61 65
46 53 56 62 63
55 59 56 58 63
71
74
61
60
58
58
69
66
57
52
55
58
59
49
43
39
Air flow [l/s]
100 200 300 400 500 600 700 800
47
38
700
0
600
500
400
300
56 66
58 68
47 57
47 57
47 57
47 57
200
100
0
0 500 1000 1500 2000 2500 3000
Air flow [m 3 /h]
Air flow [l/s]
100 200 300 400 500 600 700 800
400
300
200
100
0
0
0 500 1000 1500 2000 2500 3000
Air flow [m 3 /h]
TOWER-H 355 4E, TOWER-H 355 4D
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
Tower-H 355 4E
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 355 4D
L wA
to inlet [dBA]
L wA
to environment [dBA]
69
72
71
73
42 43 50 62 64 64
36 43 56 66 67 67
43 44 52 63 66 66
36 44 57 67 68 68
62 53
60 44
64 54
60 45
49 59
51 61
50 60
52 62
500
0 200 400 600 800
Air flow [l/s]
1000
400
300
200
100
0
0 1000 2000
200 400 600
3000 4000
Air flow [m 3 /h]
800
Air flow [l/s]
1000
400
300
200
100
0
0
0 1000 2000 3000 4000
Air flow [m 3 /h]
212 blaubergventilatoren.de
blaubergventilatoren.de
Parameters
Voltage [V]
Frequency [Hz]
Power [W]
Current [A]
Maximum air flow [m³/h (l/s)]
RPM [min⁻¹]
Sound pressure at 3 m [dBA]
Max. transported air temperature [°C]
IP rating
Motor IP rating
ErP
Tower-H 400 4E
1~230
50
457
2.00
3950 (1097)
1440
55
-30…+60
IPX4
IP54
2018
Tower-H 400 6E
1~230
50
184
0.89
2740 (761)
945
47
-30…+60
IPX4
IP54
60
249
1.10
3289 (914)
1071
49
2018 –
Tower-H 400 4D Tower-H 450 4E Tower-H 450 6E Tower-H 450 4D
3~400
50
420
0.99
3950 (1097)
1440
55
-30…+60
IPX4
IP54
2018
1~230
50
749
3.35
6180 (1717)
1400
58
-30…+60
IPX4
IP54
2018
1~230
50
268
1.25
4380 (1217)
940
50
-30…+60
IPX4
IP54
2018
3~400
50
755
1.50
5920 (1644)
1440
57
-30…+50
IPX4
IP54
2018
TOWER-H 400 4E, TOWER-H 400 4D, TOWER-H 400 6E
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
Tower-H 400 4E
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 400 4D
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 400 6E
L wA
to inlet [dBA]
L wA
to environment [dBA]
75
76
75
76
65
67
46 47 55 67 70
38 46 59 70 71
44 73 70 60 58
30 56 68 71 70
44 51 54 60 61
55 59 56 58 63
70 68
71 63
55 54
69 60
56 52
58 58
57
47
43
46
41
39
54 64
55 65
54 64
55 65
45 55
47 57
200 400 600 800
Air flow [l/s]
1000 1200
450
0
400
350
300
250
200
150
100
50
0
0 1000 2000 3000
200 400 600 800
4000 5000
Air flow [m 3 /h]
Air flow [l/s]
1000 1200
600
0
400
200
0
0 1000 2000 3000 4000 5000
Air flow [m 3 /h]
TOWER-H 450 4E, TOWER-H 450 4D, TOWER-H 450 6E
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
Tower-H 450 4E
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 450 4D
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 450 6E
L wA
to inlet [dBA]
L wA
to environment [dBA]
78
78
77
77
68
70
600
0
45 75 73 62 60
31 58 70 74 73
45 74 72 61 60
31 57 69 73 71
46 54 57 63 64
58 62 59 61 66
57
71
56
70
59
60
56
62
55
61
55
61
45
47
45
46
43
41
Air flow [l/s]
250 500 750 1000 1250 1500 1750
57 67
58 68
56 66
57 67
48 58
50 60
500
400
300
200
100
0
0 1000 2000 3000 4000 5000 6000 7000
Air flow [m 3 /h]
Air flow [l/s]
250 500 750 1000 1250 1500 1750
800
0
400
0
0 1000 2000 3000 4000 5000 6000 7000
Air flow [m 3 /h]
INDUSTRIAL VENTILATION | 2021 213
2021 | INDUSTRIAL VENTILATION
Parameters
Voltage [V]
Frequency [Hz]
Power [W]
Current [A]
Maximum air flow [m³/h (l/s)]
RPM [min⁻¹]
Sound pressure at 3 m [dBA]
Max. transported air temperature [°C]
IP rating
Motor IP rating
ErP
Tower-H 500 4D
3~400
50
1527
2.64
8435 (2343)
1460
62
-30…+50
IPX4
IP54
2018
Tower-H 500 6E Tower-H 500 6D
1~230 3~400
50
407
60
673
50
440
60
599
1.81
3.05
1.23
1.32
5680 (1578) 6532 (1814) 6000 (1667) 6122 (1701)
970
52
1120
54
978
52
1125
54
-25…+60
IPX4
IP54
-25…+60
IPX4
IP54
2018 – 2018 –
Tower-H 560 4D
3~400
50
1970
3.36
13 560 (3767)
1400
66
-25…+50
IPX4
IP54
2018
Tower-H 560 6E
1~230
50
613
2.70
9560 (2656)
930
58
-25…+50
IPX4
IP54
2018
Tower-H 560 6D
3~400
50
696
1.44
9630 (2675)
970
58
-25…+50
IPX4
IP54
2018
TOWER-H 500 4D, TOWER-H 500 6E, TOWER-H 500 6D
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
Tower-H 500 4D
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 500 6E
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 500 6D
L wA
to inlet [dBA]
L wA
to environment [dBA]
82
83
70
72
70
72
48 80 77 65 64
33 61 74 78 77
48 56 59 66 66
60 64 60 63 68
48 55 58 65 66
60 64 60 63 68
60
76
61
62
61
62
59
65
57
63
57
63
48
50
45
42
44
42
600
500
400
800
Air flow [l/s]
0 250 500 750 1000 1250 1500 1750 2000 2250 2500
700
300
200
100
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
Air flow [m 3 /h]
2000
1600
1200
800
400
Air flow [l/s]
0 250 500 750 1000 1250 1500 1750 2000 2250 2500
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
Air flow [m 3 /h]
61 71
62 72
50 60
52 62
49 59
52 62
TOWER-H 560 4D, TOWER-H 560 6E, TOWER-H 560 6D
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
Tower-H 560 4D
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 560 6E
L wA
to inlet [dBA]
L wA
to environment [dBA]
Tower-H 560 6D
L wA
to inlet [dBA]
L wA
to environment [dBA]
85
87
77
79
77
79
50 83 80 68 66 62
35 65 78 82 81 80
64 69 71 70 67 67
52 65 74 73 74 63
65 70 71 71 68 68
52 65 74 73 74 63
61 49
69 53
66 59
57 46
67 59
57 46
64 74
66 76
56 66
58 68
57 67
58 68
1000 2000 3000
Air flow [l/s]
4000
800
0
700
600
500
400
300
200
100
0
0 5000 10000 15000
Air flow [m 3 /h]
Air flow [l/s]
500 1000 1500 2000 2500 3000 3500 4000
2000
0
1000
0
0 5000 10000 15000
Air flow [m 3 /h]
214 blaubergventilatoren.de
blaubergventilatoren.de
Parameters
Voltage [V]
Frequency [Hz]
Power [W]
Current [A]
Maximum air flow [m³/h (l/s)]
RPM [min⁻¹]
Sound pressure at 3 m [dBA]
Max. transported air temperature [°C]
IP rating
Motor IP rating
ErP
Tower-H 630 6D
3~400
50
1110
2.42
12 640 (3511)
957
64
-25…+50
IPX4
IP54
2018
Tower-H 710 6D
3~400
50
2583
4.87
17 010 (4725)
945
67
-25…+70
IPX4
IP54
2018
TOWER-H 630 6D
Sound power level,
A-weighted
L wA
to inlet [dBA]
L wA
to environment [dBA]
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
82
85
69 74 76 75 72
56 70 80 79 80
72 71
68 62
63
50
61 71
64 74
Air flow [l/s]
500 1000 1500 2000 2500 3000 3500
630 6D 50 Hz
500
0
450
400
350
300
250
200
150
100
50
0
0 2000 4000 6000 8000 10000 12000 14000
Air flow [m 3 /h]
Air flow [l/s]
500 1000 1500 2000 2500 3000 3500
1200
1000
800
600
400
0
0 2000 4000 6000 8000 10000 12000 14000
Air flow [m 3 /h]
TOWER-H 710 6D
Sound power level,
A-weighted
Total
Octave frequency bands [Hz]
63 125 250 500 1000 2000 4000 8000
LpA
3 m
LpA
1 m
L wA
to inlet [dBA]
L wA
to environment [dBA]
85
88
72 78 80 79 76
58 73 83 82 83
76
71
75 66
64 52
65 75
67 77
700
0
600
500
400
1000 2000 3000
Air flow [l/s]
4000 5000
710 6D 50 Hz
300
200
100
0
0 4000 8000
1000 2000
12000
3000
16000
Air flow [m 3 /h]
Air flow [l/s]
4000 5000
2800
2400
2000
1600
1200
0
0 4000 8000 12000 16000
Air flow [m 3 /h]
INDUSTRIAL VENTILATION | 2021 215
Изтегляне
Реклама