Berker 204620 Series Operating Instructions Manual

Add to My manuals
40 Pages

advertisement

Berker 204620 Series Operating Instructions Manual | Manualzz

Bedienungsanleitung

Universeller Temperaturregler

Operating instructions for universal temperature controller

Stand 02.2019 (18/077)

204620xx

1 5 22 027 00

Übersicht Bedienungsanleitung

1 1. Sicherheitshinweis 0 3

1 2. Anwendung / Funktion / Notbetrieb ................................................................ 0 3

1 3. Hinweise zur Bedienung .................................................................................. 0 3

1 4. Regelbetrieb 0 4

1 4.1 Temporäre Solltemperatureinstellung .............................................................. 0 4

1 4.2 Auswahl der Betriebsart / Frostschutz ............................................................. 0 5

1 5. Hauptmenü 0 6

1 5.1 Untermenü Party ............................................................................................. 0 8

1 5.2 Untermenü Urlaub ........................................................................................... 0 8

1 5.3 Einstellen der Uhrzeit / des Datums ................................................................ 0 9

1 5.4 Eingabe der Solltemperaturen ......................................................................... 0 9

1 5.5 Eingabe der Tagesprogramme ........................................................................ 10

1 5.6 Information ...................................................................................................... 12

1 5.7 Einstellungen ................................................................................................... 12

1

1

1

6. Expertenmenü

7. Montage/Anschluss

8. Erstinbetriebnahme

1 9. Anschlussschaltbild und Maßzeichnung ........................................................... 17

10. Technische Daten ............................................................................................ 19

.......................................................................................................... 20

12. Gewährleistung

2

1. Sicherheitshinweis

Dieses Gerät darf nur durch eine Elektrofachkraft geöffnet und gemäß dem entsprechenden Schaltbild auf dem Gehäuse oder in der Bedienungsanleitung installiert werden. Dabei sind die bestehenden

Sicherheitsvorschriften zu beachten.

Achtung!

Der Betrieb in der Nähe von Geräten, welche nicht den EMV-Bestimmungen entsprechen, kann zur Beeinflussung der Gerätefunktionen führen. Nach der Installation ist der Betreiber, durch die ausführende Installationsfirma, in die Funktion und Bedienung der Regelung einzuweisen. Die

Bedienungsanleitung muss für Bedien- und Wartungspersonal an frei zugänglicher Stelle aufbewahrt werden.

2. Anwendung / Funktion / Notbetrieb

Dieser Unterputzregler wird zur zeitabhängigen Einzelraum- oder Fußbodentemperaturregelung für

Elektro- und Warmwasserheizungen (stromlos geschlossene Ventilstellantriebe) eingesetzt. Dabei kann das Gerät als Raumtemperaturregler, mit optionalem Fernfühler auch als Raumtemperaturregler mit

Fußbodenüberwachung oder als Fußbodentemperaturregler eingesetzt werden.

Der Notbetrieb wird ausgelöst, wenn der interne oder externe Fühler defekt ist, oder der externe Sensor in den Funktionen Raumtemperaturregler mit Fußbodenüberwachung oder Fußbodentemperaturregler nicht angeschlossen ist. Dies wird im Display mit einer Fehlermeldung und einer rot blinkenden Lampe signalisiert. Während des Notbetriebes wird eine feste Einschaltdauer von 30% gehalten, um ein

Auskühlen oder Frostschäden im Raum zu vermeiden. Die Einschaltdauer teilt sich auf in 3 Minuten Ein und 7 Minuten Aus.

3. Hinweise zur Bedienung

Das Gerät besitzt 4 Sensortastflächen, die durch die geprägten Symbole  gekennzeichnet sind.

Ihre Funktion kann sich abhängig von der Bedienung verändern und wird jeweils im Display oberhalb der Symbole  angezeigt. Das Gerät verfügt über eine Schutzfunktion, die ein unbeabsichtigtes Be- tätigen der Tastflächen verhindert. Die Funktion wird 20 Sekunden nach der letzten Berührung einer

Tastfläche aktiv und wird durch Berühren einer beliebigen Tastfläche für ca. 2 Sekunden wieder deaktiviert.

3

4. Regelbetrieb

temporäre Solltemperatureinstellung siehe 4.1

Auswahl der Betriebsart siehe 4.3

Hauptmenü siehe 5.

4.1 Temporäre Solltemperatureinstellung

Solltemperatur +/- 0,5K

Übernahme der Werte / Rückkehr zum Regelbetrieb

Nach ca. 5 Sekunden ohne Tastenbetätigung erfolgt eine automatische Rückkehr in den Regelbetrieb.

Der veränderte Temperaturwert wird dabei übernommen. Der eingestellte Solltemperaturwert gilt, bis die

Betriebsart gewechselt wird (manuell oder automatisch nach Schaltuhr), die Urlaubs- oder Partyfunktion gestartet bzw. beendet wird oder das Expertenmenü aufgerufen wird.

4

4.2 Auswahl der Betriebsart / Frostschutz

Eine Betätigung der Mode Tastfläche zu einem Wechsel der Betriebsart in der dargestellten

Reihenfolge:

– Automatik (automatische Regelung nach eingestelltem

Tagesprogramm – siehe 5.4 / 5.5)

– Komfort (dauerhafte Regelung auf Komfort-Temperatur – siehe 5.4)

– ECO (dauerhafte Regelung auf ECO-Temperatur – siehe 5.4)

– AUS (Frostschutz)

In der Betriebsart „AUS“ wird bei Unterschreitung einer Temperatur von ca. 5°C die Frostschutzfunktion ausgelöst und die Heizung aktiviert. Es wird das Heizsymbol angezeigt und die Lampe leuchtet rot. Bei

Überschreitung von ca. 6°C wird der Regler wieder ausgeschaltet. Durch diese Frostschutzfunktion werden ein Auskühlen und dadurch verursachte Frostschäden im Raum vermieden.

5

5. Hauptmenü

Untermenü

Party siehe 5.1

▼ ▼

Untermenü

Urlaub siehe 5.2

Das Hauptmenü wird mit Taste Ende beendet.

Untermenü

Uhrzeit siehe 5.3

Untermenü

Datum siehe 5.3

6

5. Hauptmenü

Untermenü

Temperatur siehe 5.4

Untermenü

Tagesprogramme siehe 5.5

Information siehe 5.6

Untermenü

Einstellungen siehe 5.7

Aufruf

Expertenmenü siehe 6.

7

5.1 Untermenü Party

Partydauer +/- 15 Minuten

Abbruch der Eingabe / Rückkehr ins Hauptmenü

Start der Partyfunktion

Mit Betätigung der Tastfläche OK wird die Partyfunktion gestartet. Bei Erreichen der eingegebenen

Zeit erfolgt automatisch ein Wechsel in die vorherige Betriebsart. Die Partyfunktion kann durch

Betätigung der Tastfläche Ende jederzeit beendet werden. Während der Partyfunktion wird auf die

Komforttemperatur geregelt.

5.2 Untermenü Urlaub

Urlaubsbeginn Monat +/- 1

Abbruch der Eingabe / Rückkehr ins Hauptmenü

Wechsel zu Urlaubsbeginn Tag

Die Eingaben „Tag Urlaubsbeginn“, „Monat Urlaubsende“ und „Tag Urlaubsende“ erfolgen analog zur Eingabe „Monat Urlaubsbeginn“. Anschließend erfolgt die Eingabe der Urlaubstemperatur

(Werkseinstellung 17°C). Mit Betätigung der Taste OK werden die Werte übernommen. Bereits eingestellte Urlaubsdaten können verworfen werden, indem das Menü „Urlaub“ erneut aufgerufen und die

Eingabe mit Ende abgebrochen wird.

8

5.3 Einstellen der Uhrzeit / des Datums

Stunde +/- 1

Abbruch der Eingabe / Rückkehr ins Hauptmenü

Wechsel zu Eingabe Minute

Die Eingabe der Minuten erfolgt analog zur Eingabe der Stunden. Wurde die Einstellung der

Minuten geändert, erfolgt mit Betätigung der Taste OK die Übernahme der Werte sowie die

Rückkehr ins Hauptmenü. Gleichzeitig werden die Sekunden auf 0 gesetzt. Die Einstellung des

Datums (Jahr, Monat, Tag) erfolgt analog zur Eingabe der Uhrzeit.

5.4 Eingabe der Solltemperaturen

Eingabe Komfort-Temperatur

Komfort-Temperatur +/- 0,5K

Abbruch der Eingabe / Rückkehr ins Hauptmenü

Übernahme des Wertes

Wechsel zu Eingabe ECO-Temperatur

In der Funktion Fußbodenregler wird hier die gewünschte Fußbodentemperatur und in der Funktion

Raumtemperaturregler die gewünschte Raumtemperatur eingestellt.

Werkseinstellung: 20°C

Auf diese Temperatur wird während der Komfort-Zeiten geregelt.

9

5.4 Eingabe der Solltemperaturen

Eingabe ECO-Temperatur

ECO-Temperatur +/- 0,5K

Abbruch der Eingabe / Rückkehr ins Hauptmenü

Übernahme des Wertes,

Rückkehr ins Hauptmenü

Der maximal einstellbare ECO-Temperaturwert beträgt Komfort-Temperaturwert – 1K.

Auf diese Temperatur wird während der ECO-Zeiten geregelt.

Werkseinstellung: 17°C

5.5 Eingabe der Tagesprogramme

Auswahl des Wochentages

Wochentag vor / zurück

Abbruch der Eingabe / Rückkehr ins Hauptmenü

Wechsel zur Eingabe Komfort- und ECO-Zeiten

10

5.5 Eingabe der Tagesprogramme

Auswahl der Komfort- (

) bzw. ECO-Zeiten ( _ )

Position +/- 15 Minuten

Beenden der Eingabe. Wurden keine Änderungen vorgenommen erfolgt eine Rückkehr zur

Auswahl des Wochentags, sonst Wechsel zur Bestätigung der Eingaben

Wechsel zwischen Komfort- und ECO-Zeiten

Werkseinstellung Komfortzeiten:

Montag bis Freitag: 05:00 … 9:00 / 16:00 … 22:00

Samstag und Sonntag: 06:00 … 22:00

5.5 Eingabe der Tagesprogramme

Bestätigung der Eingabe

Speichern der Eingabe, Wechsel ins Menü zum Kopieren der Eingabe für andere Wochentage

Abbruch der Eingabe,

Rückkehr zur Auswahl des Wochentages

11

5.5 Eingabe der Tagesprogramme

Übernahme der Eingabe für andere Wochentage

Auswahl vor / zurück

Keine Übernahme der Eingabe / Rückkehr zur Auswahl des

Wochentages

Übernahme der Eingabe für den (die) ausgewählten Wochentag(e).

5.6 Information

5.7 Einstellungen

12

Auswahl aufwärts / abwärts

Abbruch der Eingabe,

Rückkehr ins Hauptmenü

Aktivieren bzw. Deaktivieren der ausgewählten Funktion

5.7 Einstellungen

Folgende Funktionen sind verfügbar:

5.7.1.Tastensperre

Die Tastensperre wird ca. 2 Minuten nach der letzten Berührung einer Tastfläche aktiv und das

Schlüsselsymbol wird im Display angezeigt. Um die Tastflächen wieder zu aktivieren, muss eine beliebige

Tastfläche ca. 10 Sekunden lang berührt werden.

Werkseinstellung: Aus

5.7.2. Automatische Sommer-/Winterzeitumstellung

Die vereinheitlichte Sommerzeit in der Europäischen Union gilt vom letzten Sonntag im März um

2.00 Uhr MEZ bis zum letzten Sonntag im Oktober um 3.00 Uhr MESZ (Richtlinie 2000/84/EG des

Europäischen Parlaments und des Rates). Zu diesen Terminen ändert dieser Temperaturregler automatisch die Zeit. Für Zeitumstellungen zu anderen Terminen oder Regionen ohne Zeitumstellung, kann die automatische Sommer-/Winterzeitumstellung deaktiviert werden.

Werkseinstellung: Ein

5.7.3. Ventilschutzfunktion

Der Ventil- und Pumpenschutz dient der Verhinderung des Festkorrodierens des Ventilsitzes und / oder der Pumpen bei langen Stillstandszeiten. Bei Warmwasserheizungen wird die Aktivierung des

Ventilschutzes empfohlen. Ist der Ventil- und Pumpenschutz aktiviert, steuert der Regler montags 11.00

Uhr das Ventil und / oder eine Umwälzpumpe einmalig für 5 Minuten an. Der Ventil- und Pumpenschutz wird nur aktiv, wenn innerhalb der letzten Woche nicht geheizt wurde. So wird unnötig zusätzliches

Aufheizen in der Heizsaison vermieden und die Regelung nicht beeinflusst.

Werkseinstellung: Aus

5.7.4. Lernfunktion

Die Lernfunktion dient dem selbstständigen Erreichen der Komforttemperatur zum eingestellten

Zeitpunkt. Der vorgezogene Umschaltzeitpunkt von ECO auf Komfort-Temperatur stellt sich selbsttätig ein. Die Aufheizzeit variiert je nach Heizleistung und Außentemperatur.

Werkseinstellung: Aus

5.7.5. Displaybeleuchtung

Die Dauer der Displaybeleuchtung ist in folgenden Schritten einstellbar:

1. während der Bedienung und ca. 10 Sekunden nach der letzten Berührung einer Tastfläche

2. zusätzlich zu 1. während der Komfort-Zeiträume und der Partyfunktion

3. permanente Beleuchtung

Werkseinstellung: während der Bedienung und ca. 10 Sekunden nach der letzten Berührung einer

Tastfläche

13

5.7.6 Anzeigeinhalt

Bei einer Konfiguration als Fußbodentemperaturregler ist nur die Zeitanzeige aktiv. Ist der Regler nicht als

Fußbodentemperaturregler konfiguriert, so kann zwischen folgenden Anzeigeinhalten gewählt werden:

1. Zeit

2. Temperaturen

3. Zeit & Temperaturen im Wechsel

Werkseinstellung: Zeit & Temperaturen im Wechsel

6. Expertenmenü

Das Expertenmenü wird im Hauptmenü unter Punkt „Einstellungen” (siehe 5.) durch eine ca. 10

Sekunden lange Betätigung der rechten Tastfläche aufgerufen.

Achtung!

In diesem Menü werden Regelungseinstellungen vorgenommen, die nur durch eine qualifizierte Heizungs- oder Elektrofachkraft durchgeführt werden dürfen. Einstellungen im Expertenmodus können nicht durch die Resetfunktion zurückgesetzt, sondern müssen bewusst eingestellt werden.

Somit ist ein eindeutiger Nachweis der Einstellungen durch eine Person gegeben.

Folgende Einstellungen sind möglich:

6.1 Reglertyp

Es kann zwischen Raumtemperaturregler (Raum), Raumtemperaturregler mit Fußbodenüberwachung

(Raum&Boden) und Fußbodentemperaturregler (Boden) gewählt werden.

6.2 Sprache

Es kann zwischen der deutschen, der englischen, der französischen, der niederländischen, der polnischen, der tschechischen und der russischen Sprache gewählt werden.

6.3 Messkorrektur

Der gemessene Temperaturwert kann, für jeden Fühler einzeln (in Abhängigkeit der Konfiguration) im

Bereich von -5K bis +5K in 0,1K Schritten angepasst werden. Dabei wird im Display der aktuelle, unkorrigierte Messwert für den jeweiligen Fühler angezeigt (Werkseinstellung 0.0).

6.4 Reset

Nach Bestätigung werden alle Einstellungen, welche außerhalb des Expertenmenüs (ausgenommen

Uhrzeit und Datum) vorgenommen wurden, in den Auslieferzustand zurückgesetzt.

6.5 Maximale Temperatur

(nur verfügbar bei Raumtemperaturregler mit Fußbodenüberwachung sowie Fußbodentemperaturregler)

Es kann eine maximale Fußbodenfühlertemperatur im Bereich zwischen 15°C bis 42°C eingestellt werden. Somit kann eine Beschädigung des Fußbodens durch eine zu hohe Temperatur verhindert werden

(Werkseinstellung 42°C).

14

6.5 Lasteingabe (nur verfügbar bei Raumtemperaturregler und Raumtemperaturregler mit

Fußbodenüberwachung)

Um die Eigenerwärmung des Reglers kompensieren zu können, muss die Leistungsaufnahme des angeschlossenen Verbrauchers eingegeben werden. Die Leistung der Heizlast wird in kW dargestellt und ist im Bereich zwischen 0.1 und 2.3 einzustellen. Bei Zwischenwerten ist der nächst niedrigere

Wert einzustellen. Werden statt einer Elektroheizung Ventile angesteuert, ist deren geringe Leistung zu vernachlässigen und es müssen keine Änderungen vorgenommen werden (Werkseinstellung 0.1).

6.6 Regelverfahren (nur verfügbar bei Raumtemperaturregler und Raumtemperaturregler mit

Fußbodenüberwachung)

PI-PWM-Verfahren: proportional – integral, empfohlen für Warmwasserund Fußbodenheizung

2-Punkt-Verfahren: Hysterese, empfohlen für Elektrodirektheizungen und Speicherheizungen

(Werkseinstellung 2-Punkt)

6.7

Externer Sensor (nur verfügbar bei Raumtemperaturregler mit Fußbodenüberwachung und

Fußbodentemperaturregler)

An den Regler sind externe Temperaturfühler (NTC) mit einem Widerstandswert bei 25°C von 2 kΩ, 12 kΩ, 15 kΩ oder 33 kΩ anschließbar. Der verwendete Temperaturfühler muss hier ausgewählt werden

(Werkseinstellung 2 kΩ).

15

7. Montage/Anschluss

Der Regler ist zur Montage in die Unterputzdose bestimmt und darf nicht direkt Wärme- oder

Kältequellen ausgesetzt werden. Es ist darauf zu achten, dass der Regler auch rückseitig keiner

Fremderwärmung oder -kühlung, z.B. bei Hohlwänden durch Zugluft oder Steigleitungen, ausgesetzt wird. Der Regler ist auf die Tapete / den Wandbelag zu montieren. Das Gerät ist entsprechende

Schalterprogramme integrierbar. Bei Mehrfachrahmen ist der

Regler immer an unterster Stelle zu montieren.

Achtung, vor Installation Netzspannung allpolig abschalten!

Der elektrische Anschluss erfolgt gemäß Anschluss-Schaltbild

Punkt 9. Hierzu können die Steckklemmen komfortabel vorverdrahtet und bei der Montage in die Unterputzdose mit dem

Regler verbunden werden. Zum Öffnen des Gerätes oben und unten am Gehäusedeckel greifen und ziehen, wie in nebenstehender Zeichnung dargestellt.

8. Erstinbetriebnahme

Bei der Erstinbetriebnahme werden automatisch die Expertenmenüpunkte 6.2 Sprache und 6.1

Reglertyp aufgerufen. Erst nach korrekter Eingabe ist das Gerät funktionsfähig.

16

9. Anschlussschaltbild und Maßzeichnung

Last max.

2,3 kW ext. Sensor

80,7

17

28,5

9,9

21,1

Wichtiger Hinweis!

Die Einzeladern der Netzspannungsversorgung und des externen Fühlers sind durch Setzen je eines

Kabelbinders gegen Verlagerung zu sichern. Hierbei ist auf einen möglichst kurzen Abstand, maximal jedoch 15 mm, zwischen Kabelbinder und Netzanschluss bzw. Fühlerklemmen zu achten.

Klemme Netzanschluss

Klemme Fühleranschluss / SELV

18

10. Technische Daten

Betriebsspannung:

Fühler:

Schaltkontakt:

Schaltvermögen:

Einstellbereich:

Schaltdifferenz:

230V~, 50Hz

NTC – intern

NTC – extern anschließbar

Relais / Schließer, Typ 1.B

10 (2) A / 230V~

5 … 30°C für Raumtemperaturregelung

10 … 42°C für Fußbodentemperaturregler

<1K

Absenkung: Absenktemperatur einstellbar

Raumtemperaturregelung 5 … 29°C

Fußbodentemperaturregelung 10 … 41°C

(Werkseinstellung 17°C)

Anzeige: beleuchtetes, grafisches Display

Elektrischer Anschluss: Schraub-Steckklemmen

Schutzart:

Schutzklasse:

Gangreserve: zul. Luftfeuchte: netzspannungsseitig 0,75 – 2,5 mm 2 niederspannungsseitig 0,08 – 1,5 mm 2

IP 30, nach entsprechender Montage

II, nach entsprechender Montage ca. 5 Tage max. 95%, nicht kondensierend

Lagertemperatur: – 20 … + 70°C

Umgebungstemperatur: 0 … 35°C

Farbe Gehäuse:

Material Gehäuse: polarweiß-, schwarz glänzend

PMMA, ASA

Montage / Befestigung: in Unterputzdose, in entsprechende Flächenschalterprogramme adaptierbar

Verschmutzungsgrad: 2

Bemessungsstoßspannung: 4.000 V

Energieeffizienzklasse: I oder IV (Beitrag zur jahreszeitbedingten Raumheizungs-Energieeffizienz 1% oder 2%)*

* Temperaturregler mit auswählbarem Regelverfahren. Je nach gewähltem Regelverfahren werden diese

Regler unterschiedlichen Klassen zugeordnet (2-Punkt: Klasse I; PI-PWM: Klasse IV).

19

11. Zubehör

- externer Temperaturfühler 164

12. Gewährleistung

Die von uns genannten technischen Daten wurden unter Laborbedingungen nach allgemein gültigen

Prüfvorschriften, insbesondere DIN-Vorschriften, ermittelt. Nur insoweit werden Eigenschaften zugesichert. Die Prüfung der Eignung für den vom Auftraggeber vorgesehenen Verwendungszweck bzw. den Einsatz unter Gebrauchsbedingungen obliegt dem Auftraggeber; hierfür übernehmen wir keine

Gewährleistung. Änderungen vorbehalten.

Berker GmbH & Co. KG · Klagebach 38 · D-58579 Schalksmühle www.hager.com

20

21

Table of contents, overview

1 1. Safety information ......................................................................................... 0 23

1 2. Application / functional description / emergency operation ........................... 0 23

1 3. Operating instructions ................................................................................... 0 23

1 4. Control operation .......................................................................................... 0 24

1 4.1 Temporary set temperature setting ............................................................... 0 24

1 4.2 Selection of the operating mode / antifreezing function ................................. 0 25

1 5. Main menu .....................................................................................................

0 26

1 5.1 Submenu “Party” ........................................................................................... 0 28

1 5.2 Setting of the holiday data ............................................................................ 0 28

1 5.3 Setting of the time / date .............................................................................. 0 29

1 5.4 Setting of the set temperatures ..................................................................... 0 29

1 5.5 Entry of the weekday programs ...................................................................... 30

1 5.6 Information ...................................................................................................... 32

1 5.7 Settings ........................................................................................................... 32

1 6. Experts menu .................................................................................................. 34

1 7. Mounting / connection .................................................................................... 36

1 8. First start-up and commissioning………………. .............................................. 36

1 9. Wiring diagram and dimensioned drawing ........................................................ 37

10. Technical data .................................................................................................. 39

11. Accessories

12. Warranty

..................................................................................................... 40

......................................................................................................... 40

22

1. Safety information

Expert electricians only may open this device in due compliance with the wiring diagram shown in the housing cover / on the housing / represented in the corresponding operating instructions. All expert electricians charged with the execution of such works must comply with the relevant safety regulations currently operative and in force. Caution: The operation of the controller in the vicinity of other devices that do not comply with the EMC directives may affect its functions. The company charged with the installation of the device must, after the completion of the installation works, instruct the user of the control system into its functions and in how to operate it correctly. These operating instructions must be kept at a place that can be accessed freely by the operating and/or servicing personnel in charge.

2. Application / functional description / emergency operation

The controller described in these instructions is provided for flush installation and has been specially devised for the time-dependent control of the temperatures in individual rooms or of the temperatures produced by electric or warm-water heating systems (systems with normally closed valve actuators). The device can be used as floor or as room temperature controller with additional floor temperature controller function. Operation in emergency mode is triggered if the internal or external sensor is defective. The same applies if no sensor has been connected when using the device as room temperature controller with additional floor monitoring function and also when using it as floor temperature controller. An error message appears on the display and an indicator lamp starts blinking red to indicate this condition.

During operation in emergency mode a fixed 30% duty cycle is being maintained to prevent the related room from cooling down thoroughly and protect it against frost damage. The activation time divides into a 3-minute ACTIVE and a 7-minute OFF time.

3. Operating instructions

The device is equipped with 4 touch keys, all of which have been marked by the symbol  . The functions allocated to them may vary in dependence on the operation requirements. The related function is being indicated on the display which exists above the corresponding keys  . A special protective function helps prevent an inadvertent activation of the touch keys. This function is activated 20 seconds after any of the touch keys has last been activated. Actuating any of the touch keys deactivates this function again for 2 seconds.

23

4. Control operation

Temporary set temperature setting see 4.1

Selection of the operating mode see 4.3

Main menu see 5.

4.1 Temporary set temperature setting

Set temperature +/- 0,5K

Acquisition of the values / Return to normal control mode

If no key has been activated within a period of approx. 5 seconds, the system returns to normal control mode again. The changed temperature value is being taken over and imported. The adjusted set temperature continues to be effective until the moment the operating mode is changed, no matter if changing manually or automatically. The same applies if the holiday or party function has been started or cancelled or the experts menu been called up.

24

4.2 Selection of the operating mode / antifreezing function

Actuating the touch key Mode allows to change the operating mode in the order shown below:

– Automatic mode (control in dependence on the adjusting weekday program - see 5.4 / 5.5)

– Comfort mode (permanent control targeted at maintaining the adjusted comfort temperature - see 5.4)

– ECO mode (permanent control targeted at maintaining the adjusted ECO temperature - see 5.4)

– Operating mode “OFF” (antifreezing mode)

In “OFF” mode, the controller activates the heating when underrunning a temperature level of approx.

5°C and deactivates the operations when exceeding a temperature level of approx. 6°C. This antifreezing function helps prevent rooms from cooling down thoroughly and protects against the occurrence of frost damage.

25

5. Main menu

Submenu

Party see 5.1

Submenu

Holiday see 5.22

▼ ▼

Submenu

Time see 5.3

▼ ▼

Submenu

Date see 5.3

Actuating the key End terminates the main menu.

26

5. Main menu

Submenu

Temperature siehe 5.4

Submenu

Weekday programms see 5.5

Information see 5.6

Submenu

Settings see 5.7

Calling of the experts menu see 6.

27

5.1 Submenu “Party”

Party duration+/- 15 minutes

Termination of entries / returning to the main menu

Start of the “Party” function

Actuating the OK touch key starts the party function. Once the preadjusted time has been attained, the system switches automatically back to the previous operating mode. Actuating the touch key

End cancels the party function at any time. While operating in party mode, all control operations are performed in dependence on the actually adjusted comfort temperature.

5.2 Submenu “Holiday”

Month in which holidays begin +/- 1

Termination of the data entry, returning to the main menu

Changing over to the day on which holidays begin

The settings “Day on which holidays begin”, “Month in which holidays end” and “Day on which holidays end” are made in the same manner as explained above with regard to the setting “Month in which holidays begin”. Following this, the holiday temperature is to entered. Actuating the key OK confirm the settings. Actuating the key End after calling up the holiday submenu cancels all already existing holiday data.

28

5.3 Setting of the time / the date

Hour +/- 1

Termination of entries / returning to the main menu

Changing to the minute entry display

For the entry of the minutes proceed in the same manner as explained above with regard to the entry of the hours. Actuating the OK key after a change of the minutes imports the changed values and brings the operator back to the main menu. At the same time, the seconds are being reset to “0”. For the setting of the date (year, month and day) proceed in the same manner.

5.4 Entry of the set temperatures

Entry of the comfort temperature

Comfort temperature +/- 0,5K

Termination of entries / returning to the main menu

Import of the selected value and changeover to the

ECO temperature entry display

If using the device as floor temperature controller, the desired floor temperature can be set using this menu. The same applies in regard to the setting of the desired room temperature when using it as room temperature controller.

Factory setting: 20°C

During all comfort times the control operations will be performed to meet this value.

29

5.4 Entry of the set temperatures

Entry of the ECO temperature

ECO temperature +/- 0,5K

Termination of entries, returning to the main menu

Import of the selected value, returning to the main menu

The maximum adjustable ECO temperature value corresponds to the comfort temperature value – 1K.

During all ECO times the control operations will be performed to meet this value.

Factory setting: 17°C

5.5 Entry of the weekday programs

Selection of the weekday

Weekday onward / backward

Termination of entries / returning to the main menu

Changing to the comfort and ECO time entry display

30

5.5 Entry of the weekday programs

Selection of the comfort (

) and ECO ( _ ) times

Position + / – 15 minutes

Termination of entries. If no changes have been made, the system returns to the display for the selection of the weekday. Otherwise, it changes over to the entry confirmation display

Shifting between comfort or ECO time period

Comfort times, factory settings:

Monday to Friday: 05:00 … 9:00 a.m. / 16:00 … 22:00 p.m.

Saturday and Sunday: 06:00 a.m. … 22:00 p.m.

5.5 Entry of the weekday programs

Confirmation of entries

Storing of the entries, change to the menu enabling the copying of entries with respect to other weekdays

Termination of entries / returning to the weekday selection display

31

5.5 Entry of the weekday programs

Import of the entries made with regard to other weekdays

Selection forward / backward

No import of the entry, returning to the weekday selection display

Import of entries with respect to the selected weekday(s).

5.6 Information

5.7 Settings

32

Selection downward / upward

Termination of entries / returning to the main menu

Activation or deactivation of the selected function

5.7 Settings

The following functions are available:

5.7.1. Keylock

The keylock is activated about 2 minutes after one of the touch keys has been actuated and the key symbol appears on the display to indicate this. Touching any of the touch keys for approx.10 seconds activates them again.

Factory setting: OFF

5.7.2. Automatic change to daylight saving and standard time

The harmonised daylight saving time in the European Union takes effect as of the last Sunday in March, i.e. as of 2.00 o’clock a.m. CET and lasts until to 3.00 o’clock a.m. on the last Sunday in October (CEST) each year (Directive 2000/84/EC of the European Council and Parliament). This room temperature controller changes the time all automatically at these dates. The automatic change to daylight saving and standard time can also be deactivated to enable the changing of the time at other dates or to meet the time conditions in other regions.

Factory setting: ON

5.7.3. Valve and pump protection function

The valve and pump protection function helps prevent the valve seat and/or the pump from corroding up during longer stop times. Whenever warm-water heating systems are to be controlled, it is recommended to activate the valve protection function. Once the valve and pump protection has been activated, the controller actuates the related valve or triggers, at each time, a circulating pump every Monday at

11.00 o’clock a.m. for a 5-minute time.

Factory setting: OFF

5.7.4. Learn function

The learn function serves for the autonomous attaining of the “heating” comfort temperature value at a preset time. The antedated point at which the system switches from ECO over to comfort temperature sets itself all autonomously. Depending on the calorific output and the prevailing outside temperature, the heating time will vary. The learning function is available only if operating in heating mode.

Factory setting: OFF

5.7.5. Backlighting of the display

The length of time during which the display backlight is on, can be selected as follows:

1. Backlight during operation plus 10 seconds after the last actuation of any of the touch keys

2. In addition to above 1.: Backlight during the “heating” comfort times and during operation in party mode

3. Permanent backlight

Factory setting: during operation plus 10 seconds after the last actuation of any of the touch keys

33

5.7.6 Display indications

If configuring the device for use as floor temperature controller, only the time indication is active. If the device has not been configured for use as floor temperature controller, the operator can select between the following indications:

1. Time

2. Temperature

3. Time & temperature (alternating)

Factory setting: Time & temperature (alternating)

6. Experts menu

Depressing the right touch key and keeping it depressed for 10 seconds after accessing the “settings” submenu (see 5.) from the main menu, enables to call the experts menu.

Caution! This menu enables to make control settings that may only be performed by a qualified heating specialist or an expert electrician. The settings made while operating in this mode cannot be reset via the reset function and have to be made knowingly, therefore.

The following settings are available:

6.1 Controller type

The following controller configuration variants can be selected: “Room temperature controller”, (Room),

“Room temperature controller with floor temperature controller function” (Room&Floor) or “Floor temperature controller” (Floor).

6.2 Language

The operator can select between the following languages: German, English, French, Dutch, Polish and

Russian.

6.3 Measuring correction

The measured temperature value can, in dependence on the related configuration, be adjusted with regard to each individual sensor within a range from -5 K to +5K at 0.1K steps. At the same time, the uncorrected value measured by the related sensor is being indicated on the display (factory setting 0.0).

6.4 Reset

Actuating this function resets all settings made outside of the experts menu (except for time and date) to the condition as delivered.

6.5 Maximum temperature

(setting possible only when using the device as room temperature controller with floor temperature controller function or as floor temperature controller) The maximum temperature measured by the floor temperature can be defined within a range from 15 to 42°C. Damages to the floor in consequence of excessive temperatures can thus be prevented (factory setting 42°C).

34

6.6 Entry of the connected load (entry possible only when using the device as room temperature controller with floor temperature controller function or as floor temperature controller) In order to allow to compensate the self heating of the device, the power consumption of the connected consumer needs to be entered. The power consumed in consequence of the connected heating load is indicated in kW and can be adjusted within a range from 0.1 to 2.3. With intermediate values, the nearest lower value needs to be set. If actuating valves instead of controlling an electric heating system, the low power consumption of these valves can be neglected, so that no changes need to be made (factory setting 0.1).

6.7 Algorithm (entry possible only when sensor position Room, Room&Floor or Room ext.)

PI-PWM method (proportional–integral), recommended for the control of warmwater and floor heating systems.

Two-point method (hysteresis), recommended for the control of electric direct or storage heating systems

Factory setting: two-point method

6.8

External sensor (entry possible only when sensor position Floor, Room&Floor or Room ext.)

The device allows to connect external temperature sensors (NTC) with resistance values at 25°C of 2 kΩ, 12 kΩ, 15 kΩ oder 33 kΩ. The actually used temperature sensor needs to be selected here (factory setting 2 kΩ).

35

7. Mounting / connection

The controller is determined for installation in an UP box and may not be exposed to any heat or cold sources. Furthermore, care must be taken to ensure that the device is not exposed to the influence of foreign heat or cold sources that warm or cool the device at its back (through air flows in cavity walls or the temperatures radiated by ascending pipelines, f. ex.). The controller should be mounted on the wallpaper / the wall covering. The device can be integrated into corresponding flush switch installation frame systems. If using multiple frames, the controller needs always to be mounted in the lowest position.

Caution: Prior to performing any installation works, always make sure to disconnect the mains voltage at all poles!

The electrical connection is to be realised as shown in the connection diagram in section 9 herein. The plug-type terminals can comfortably be pre-wired for this purpose and connected to the controller while installing it into the under plaster box. The opening of the device is realised as described in the drawing below by holding the housing cover at the top and bottom and pulling it open.

8. First start-up and commissioning

When starting the controller up for the first time, the experts menu items 6.2 Language and 6.1,

Controller type are being called up all automatically.

The device is operative only if all entries have been made correctly.

36

9. Wiring diagram and dimensioned drawing

Load max.

2,3 kW ext. sensor

80,7

37

28,5

9,9

21,1

Important Notice!

The single wires of both the power supply cable and the sensor line need to protected against shifting by securing them with one cable tie each as shown here below. In so doing, care is to be taken to ensure that the distance between cable tie and power supply- or sensor line terminal respectively, is always kept as short as possible (max. 15 mm).

Power supply terminal

Sensor line terminal / SELV

38

10. Technical data

Operating voltage:

Sensor:

Switching contact:

Switching capacity:

Setting range:

Switching difference:

230V~, 50Hz

NTC – internal

NTC – externally connectable relay (make contact), type 1.B

10 (2) A / 230V~

5 … 30°C (control of room temperatures)

10 … 42°C (control of floor temperature)

<1K

Temperature decrease: decrease temperature adjustable as follows:

Display:

Electrical connection: control of room temperatures: 5 … 29°C control of floor temperatures: 10 … 41°C

(factory setting 17°C) graphic display, backlit pluggable screw terminals

0,75 – 2,5 mm² (power supply side)

Degree of protection:

Protection class:

Power reserve:

0.08 – 1.5 mm² (low voltage side)

IP 30, after corresponding installation

II, after corresponding installation approx. 5 days

Admissible air moisture: max. 95%, non condensing

Storage temperature: – 20 … + 70°C

0 … 35°C Ambient temperature:

Housing colour:

Housing material: polar white, black glossy made of PMMA or ASA

Installation / mounting: in an UP box, suited for integration into corresponding flush mounted

Degree of pollution: switch frame installation systems

2

Rated impulse voltage: 4.000 V

Energy efficiency class: I or IV (contribution to seasonal space heating energy efficiency 1% or 2%)*

*Temperature controllers with selectable control method. These controllers are, depending on the actually selected control method, allocated to different classes (2-point: class I; PI-PWM: class IV).

39

11. Accessories

– External temperature sensor 164

12. Warranty

The technical data specified herein have been determined under laboratory conditions and in compliance with generally approved test regulations, in particular DIN standards. Technical characteristics can only be warranted to this extent. The testing with regard to the qualification and suitability for the client’s intended application or the use under service conditions shall be the client’s own duty. We refuse to grant any warranty with regard thereto. Subject to change without notice.

Berker GmbH & Co. KG · Klagebach 38 · D-58579 Schalksmühle www.hager.com

40