Datacom Systems 1000BT-AT-SX Quick Installation Manual

Add to My manuals
2 Pages

advertisement

Datacom Systems 1000BT-AT-SX Quick Installation Manual | Manualzz

DATACOM

systems ®

6

Connecting a 1000BT-AT-SX to the the Network

DATACOM

SYSTEMS INC

Access Your Network ™

Compliance Testing

CAUTION: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Certifications

This equipment has been tested and found to meet the radiated and conducted emission limits for a Class B product of EN 55022 to the EMC Directive

89/336/EEC requirements.

This equipment has been tested and found to meet the immunity levels for

Class 1 tested to level 2 for EN 6100-4-2 , tested to level 3 for EN 61000-4-

3 , tested to level 2 for EN 61000-4-4 , and tested to level 3 for EN 61000-4-

5 to the EN 50082-1 requirements and meets the Class A requirements for EN

61000-3-2 and EN 61000-3-3 .

This equipment has completed the Product Safety Review and found to meet the

Low Voltage Directive 72/23/EEC (1993) requirements.

DATACOM

systems ®

1000BT-AT-SX Full-Duplex Tap

Quick Installation Guide

FIGURE 2 — 1000BT-AT-SX Simple Connectivity Diagram

To connect the 1000BT-AT-SX into the network, refer to FIGURE 2 and follow these steps:

IMPORTANT: The maximum length of 90 meters must not be exceeded between end-points.

1. Before powering the TAP, connect one of the network device cables to the 1000BT-AT-SX RJ45 port NETWORK A connector.

2. Before powering the TAP, connect the other network device cable to the 1000BT-AT-SX RJ45 port NETWORK B connector. Ensure link has been established between the NETWORK A device and NET-

WORK B device.

3. Connect the Power Supply barrel connector into the POWER port of the 1000BT-AT-SX and then plug the Power Supply into the external power source wall receptacle. The POWER LED to the right of the RJ connectors illuminates indicating power is on.

The Rx-A , Tx-A , Rx-B , and Tx-B LEDs illuminate as data is passed back and forth between the NETWORK A and NETWORK B device.

4. Connect one tap cable from the 1000BT-AT-SX RJ45 port TAP A connector into one port of the Network Analysis Tool interface card.

The TAP-A LINK LED illuminates indicating link has been established between the TAP A connector and Network Analysis Tool interface card.

5. Connect the other tap cable from the 1000BT-AT-SX RJ45 port TAP

B connector into the other port of the Network Analysis Tool interface card. The TAP-B LINK LED illuminates indicating link has been established between the TAP B connector and Network Analysis Tool interface card.

Copyright

Copyright © 2004-2010 by Datacom Systems, Inc. All rights reserved.

Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Datacom Systems, Inc. To obtain this permission, write to the attention of the Datacom Systems legal department at

9 Adler Drive, East Syracuse, New York 13057-1290, or call 315-463-9541.

Customer Service

This Quick Installation Guide was written to help you get to know your new

10/100/1000BT-AT-SX quickly. We would welcome any comments or suggestions you may have regarding this Quick Installation Guide. Please send your remarks and recommendations via mail, telephone, facsimile, or Internet E-mail.

Datacom Customer Service personnel are available via telephone, facsimile, and

Internet E-mail. Please leave a voice message and our Customer Service Staff will return your call as soon as possible.

Mail

: Datacom Systems, Inc.

Customer Service

9 Adler Drive

East Syracuse, NY 13057-1290

Tel

: (315) 463-9541

FAX

: (315) 463-9557

E-mail

: [email protected]

World Wide Web —

You can obtain additional information about

Datacom Systems, Inc. and its products and services from the World Wide Web at http://www.datacomsystems.com

or [email protected].

May 2010 Part Number: 541-0078-A.01

Warranty

Datacom Systems, Inc. (DSI) warrants that the hardware which it supplies will be free from significant defects in materials and workmanship for a period of two years from the date of delivery (Warranty Period), under normal use and conditions. In the event of any such defect, you can return an item of defective hardware, freight prepaid, to

DSI during the Warranty Period, and DSI will repair or replace the defective equipment and return it to you, freight prepaid. If DSI determines that the equipment is not defective, it will return it to you, freight collect. DSI shall have no responsibility for any deficiency resulting from accidents, misuse, modifications, power disturbances

(including use of a power supply not specified by DSI), or various other forms of disaster, e.g., earthquakes, floods, etc.

PLEASE DO NOT ATTEMPT TO RETURN ANY ITEM PRIOR TO RECEIVING

A RETURN MATERIAL AUTHORIZATION (RMA) NUMBER FROM DATACOM

CUSTOMER SERVICE AT (315) 463-9541

Limitation On Liability

The warranties set forth above are exclusive and in lieu of all other warranties.

Datacom Systems, Inc. (DSI) makes no other warranties, expressed or implied, and

DSI expressly disclaims all other warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose. Moreover, the provisions set forth above state DSI’s entire responsibility and your sole and exclusive remedy with respect to any breach of warranty or contract.

No liability for consequential damages. Under no circumstances and under no theory of Liability shall DSI be liable for costs of procurement of substitute products or services, lost profits, lost savings, loss of information or data, or any other special, indirect, consequential or incidental damages, arising in any way out of the sale of, use of, or inability to use, any DSI product or service, even if DSI has been advised of the possibility of such damages.

DATACOM

systems ®

1000BT-AT-SX

QUICKinstall

1 1

What’s in the Package

Instructions

AC•Power Cable

4

Installing a 1000BT-AT-SX in an Equipment Rack

Prior to putting the 1000BT-AT-SX in a standard 19-inch rack you may want to contact your 1000BT-AT-SX representative to discuss a rack mount option or ...

DATACOM

SYSTEMS INC

Access Your Network ™

In any case, a couple of equipment considerations should be noted:

• Do you have universal or wide spacing flanges?

• The 1000BT-AT-SX occupies 1 unit of space when properly fastened in a universal flange. The 1000BT-AT-SX occupies part of 2 adjoining units of space when improperly fastened in a wide spacing hole of a universal or wide-space flange.

Power Supply

1000BT-AT-SX Full-Duplex Tap

2

Introduction

The 1000BT-AT-SX is a single-port full-duplex device that provides an easy method to rapidly and effectively deploy your analysis tools to monitor 1000 BaseT traffic between your network devices.

Typically the tap is installed on a critical 1000 BaseT link in the network where monitoring and analysis capabilities are important.

1000BT-AT-SX features and benefits:

• 1000 BaseT compatible

• Full duplex monitoring

• Power fault tolerant

• Standard RJ45 and SX connectors

1000BT-AT-SX with thumbscrew bracket to mount in RMC-3 rack mount

3

1000BT-AT-SX Specifications

Feature

Channel

Cable Type

Port Connectivity

NETWORK A

NETWORK B

TAP A

TAP B

Distance Limit

Power Requirements

Operating Temperature

Storage Temperature

Humidity

Dimensions

Weight

Specification

One directional 1000 BaseT Ethernet

CAT 5E and Mulimode fiber

RJ45

RJ45

SX

SX

90 meter maximum length between network end-points. Tap typically 1 meter.

External power supply 5 VDC, 1 A

0 O to 40 O C (32 O to 104 O F)

-30 O to 65 O C (-22 O to 149 O F)

Less than 95 O C non-condensing

1.10" (H) x 5.75" (W) x 5.75" (D)

(includes rack mount bracket)

28 mm (H) x 146 mm (W) x 146 mm (D)

Unit - 12 ounces; Shipping - 2 pounds

Three devices shown mounted in optional rack panel

Single-mount rack bracket option.

Single device shown with rack mount bracket

Dimensions are in millimeters

ANSI/EIA-310-D-1992 Mounting Flange Dimensional Requirements

5

Functional Operation

Refer to FIGURE 1 for a diagram of the functional operation of the

1000BT-AT-SX.

FIGURE 1 — 1000BT-AT-SX Functional Diagram

advertisement