BELL LABS INNOVATIONS Lucent Technologies Stinger MS+ Getting Started Manual
Quảng cáo
Quảng cáo
Stinger
®
MS+
Getting Started Guide
Part Number: 363-217-002R9.7
For software version 9.7.0
August 2004
Copyright © 2004 Lucent Technologies Inc. All rights reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts, or licensing, without the express written consent of Lucent Technologies. For permission to reproduce or distribute, please email your request to [email protected]
.
Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing, but information is subject to change. For latest information, refer to online product documentation at www.lucent.com/support .
European Community (EC) RTTE compliance
Hereby, Lucent Technologies, declares that the equipment documented in this publication is in compliance with the essential requirements and other relevant provisions of the Radio and Telecommunications Technical Equipment (RTTE) Directive 1999/5/EC.
To view the official Declaration of Conformity certificate for this equipment, according to EN 45014, access the Lucent INS online documentation library at http://www.lucentdocs.com/ins .
Safety, compliance, and warranty Information
Before handling any Lucent Access Networks hardware product, read the Edge Access and Broadband Access Safety and Compliance Guide included in your product package. See that guide also to determine how products comply with the electromagnetic interference (EMI) and network compatibility requirements of your country. See the warranty card included in your product package for the limited warranty that Lucent
Technologies provides for its products.
Security statement
In rare instances, unauthorized individuals make connections to the telecommunications network through the use of access features.
Trademarks
Lucent, the Lucent logo, and all Lucent brand and product names are trademarks or registered trademarks of Lucent Technologies Inc. Other brand and product names are trademarks of their respective holders.
Ordering Information
You can order the most up-to-date product information and computer-based training online at http://www.lucentdocs.com/bookstore .
Feedback
To comment on this information product, go to the Online Comment Form ( http://www.lucent-info.com/comments/enus/ ) or email your comments to the Comments Hotline ( [email protected]
).
Lucent Technologies
Customer Service
Customer Service
Product and service information, and software upgrades, are available 24 hours a day.
Technical assistance options accommodate varying levels of urgency.
Finding information and software
To obtain software upgrades, release notes, and addenda for this product, log in to
Lucent OnLine Customer Support at http://www.lucent.com/support .
Lucent OnLine Customer Support also provides technical information, product information, and descriptions of available services. The center is open 24 hours a day, seven days a week. Log in and select a service.
Obtaining technical assistance
Lucent OnLine Customer Support at http://www.lucent.com/support provides access to technical support. You can obtain technical assistance through email or the
Internet, or by telephone. If you need assistance, make sure that you have the following information available:
■
■
■
■
Active service or maintenance contract number, entitlement ID, or site ID
Product name, model, and serial number
Software version
Software and hardware options If supplied by your carrier, service profile identifiers (SPIDs) associated with your line
■
■
■
■
Your local telephone company’s switch type and operating mode, such as AT&T,
5ESS Custom or Northern Telecom National ISDN-1
Whether you are routing or bridging with your Lucent product
Type of computer you are using
Description of the problem
Obtaining assistance through email or the Internet
If your services agreement allows, you can communicate directly with a technical engineer through Email Technical Support or a Live Chat. Select one of these sites when you log in to http://www.lucent.com/support .
Calling the technical assistance center (TAC)
If you cannot find an answer through the tools and information of Lucent OnLine
Customer Support or if you have a very urgent need, contact TAC. Access Lucent
OnLine Customer Support at http://www.lucent.com/support and click Contact Us for a list of telephone numbers inside and outside the United States.
Alternatively, call 1-866-LUCENT8 (1-866-582-3688) from any location in North
America for a menu of Lucent services. Or call +1 510-747-2000 for an operator.
You must have an active services agreement or contract.
Stinger® MS+ Getting Started Guide iii
Contents
About This Guide ..............................................................................xiii
Verifying the control module model ........................................................... 1-7
Optical trunk module connections .............................................................. 2-5
DS3-ATM or E3-ATM trunk module connections ...................................... 2-5
Stinger® MS+ Getting Started Guide v
Contents
Connecting to monitor Stinger unit alarm status .............................................. 2-7
Connecting a Stinger unit to monitor the alarm status of other devices........... 2-8
Connections from the control module ........................................................ 2-8
Chapter 3 Determining the Operating Status ..................................................3-1
Chapter 4 Stinger Operational Overview .........................................................4-1
Onboard flash memory and software updates ................................................... 4-4
Verifying software and control module versions ........................................ 4-5
Chapter 5 Configuring the Control Module and System Timing ....................5-1
Network connection to a workstation console .................................................. 5-2
Connecting a dial-in backup management connection ..................................... 5-3
Backup management with an external modem .......................................... 5-3
Backup management with an internal modem .......................................... 5-5
vi Stinger® MS+ Getting Started Guide
Contents
Verifying a LAN connection for administrators ............................................... 5-14
Loss of BITS signal indications and fall-back............................................. 5-15
Changing the BITS clock source................................................................ 5-16
Using a LIM or trunk module clock source ..................................................... 5-16
Configuring trunk ports as eligible clock sources ...................................... 5-17
Typical trunk port clock source configurations ......................................... 5-17
Chapter 6 Installing and Removing Modules ...................................................6-1
Stinger® MS+ Getting Started Guide vii
Contents
Appendix C Safety-Related Electrical, Physical, and Environmental
Information ................................................................................. C-1
Special requirements and recommendations for installation and maintenance ......C-5
viii Stinger® MS+ Getting Started Guide
Figures
Figure 1-4 Wrist strap plugged into a grounding jack ........................................ 1-5
Figure 1-6 Model B control module interfaces ................................................... 1-9
Figure 1-8 OC3-ATM trunk module fiber optic connection points .................. 1-11
Figure 1-9 OC12-ATM trunk module fiber optic connection points ................ 1-11
Figure 1-10 DS3-ATM or E3-ATM trunk module connection points................. 1-11
Figure 1-11 TRAM module connection points ................................................... 1-12
Figure 1-12 Fast Ethernet trunk module connection points .............................. 1-12
Figure 2-1 Stinger MS+ chassis models for rack mounting ................................ 2-2
Figure 2-3 Connecting to LPMs in a Stinger MS+ unit ...................................... 2-4
Figure 2-4 Connecting an OC3-ATM trunk module .......................................... 2-5
Figure 2-5 Connecting a DS3-ATM or E3-ATM trunk module .......................... 2-6
Figure 2-7 Connecting to the alarm input port .................................................. 2-9
Figure 4-1 Example of DSLAM operations ......................................................... 4-1
Figure 5-1 Serial management connection to a Stinger MS+............................. 5-2
Figure 5-3 Backup administrative connection with a modem to the
Stinger MS+ unit ............................................................................... 5-4
Figure 5-4 Connection for internal modem........................................................ 5-6
Figure 5-5 Default netmask for class C IP address ............................................ 5-10
Figure 5-6 Local backbone router to be used as default route.......................... 5-13
Figure B-1 USOC RJ-21X 50-pin connector ....................................................... B-3
Stinger® MS+ Getting Started Guide ix
Tables
Control module model designations and product codes ................... 1-7
Control module models and features ................................................ 1-8
Status lights on the control module .................................................. 3-4
Location of configuration information .............................................. 4-5
IP address classes and number of network bits ............................... 5-10
Decimal subnet masks and prefix lengths ....................................... 5-11
Diagnostic port and cable pinouts ..................................................... B-1
Alarm input pinouts .......................................................................... B-2
Upper connector pin assignments for two-wire connections............ B-5
Middle connector pin assignments for two-wire connections
(72-port LIM only) ............................................................................ B-6
Lower connector pin assignments for four-wire connections........... B-7
Upper connector pin assignments for four-wire connections ........... B-8
Stinger electronic and electrical specifications .................................. C-1
Stinger T1 module USOC jacks and codes......................................... C-2
Stinger FS minimum ground wire sizes ............................................ C-3
Stinger MS+ physical specifications .................................................. C-3
Stinger MS+ site specifications .......................................................... C-4
Stinger® MS+ Getting Started Guide xi
About This Guide
What is in this guide
This guide explains how to perform the following installation and basic configuration tasks on a Stinger MS+ unit:
■
■
■
Physical installation of the Stinger chassis
Connection of an administrative terminal to the control module
Configuration of the control module for basic network connectivity
This guide also provides Stinger technical specifications and an operational overview of the Stinger. When you finish performing the instructions in this guide, the Stinger will be installed and you will be able to access it via a Telnet connection for further configuration.
Note You may also use this guide to configure the basic control module functions of the Stinger IP2000 control module. For detailed configuration information for the gigabit Ethernet interface, ATM configuration and aggregation, IGMP multicast, and other IP2000 capabilities, see the Stinger IP2000 Configuration Guide .
What you should know
Warning Before installing your Stinger unit, be sure to read the safety instructions in the Edge Access and Broadband Access Safety and Compliance Guide . For information
specific to your unit, see Appendix C, “Safety-Related Electrical, Physical, and
The procedures in this guide require you to understand and follow the safety practices at your site, as well as those identified in this guide. Before installing any hardware, check the installation location for adequate temperature, humidity, and electrical requirements. Work closely with the network manager and other systems integration personnel to ensure a functional installation.
Documentation conventions
Following are all the special characters and typographical conventions used in this manual:
Convention
Monospace text
Meaning
Represents text that appears on your computer’s screen, or that could appear on your computer’s screen.
Stinger® MS+ Getting Started Guide xiii
About This Guide
Stinger documentation set
|
>
Convention
Boldface monospace text
Italics
[ ]
Key1+Key2
Press Enter
Meaning
Represents characters that you enter exactly as shown (unless the characters are also in italics —see Italics , below). If you could enter the characters but are not specifically instructed to, they do not appear in boldface.
Represent variable information. Do not enter the words themselves in the command. Enter the information they represent. In ordinary text, italics are used for titles of publications, for some terms that would otherwise be in quotation marks, and to show emphasis.
Square brackets indicate an optional argument you might add to a command. To include such an argument, type only the information inside the brackets. Do not type the brackets unless they appear in boldface.
Separates command choices that are mutually exclusive.
Points to the next level in the path to a parameter or menu item. The item that follows the angle bracket is one of the options that appear when you select the item that precedes the angle bracket.
Represents a combination keystroke. To enter a combination keystroke, press the first key and hold it down while you press one or more other keys. Release all the keys at the same time.
(For example, Ctrl+H means hold down the Ctrl key and press the H key.)
Means press the Enter or Return key or its equivalent on your computer.
Introduces important additional information.
Note
!
Caution
Warns that a failure to follow the recommended procedure could result in loss of data or damage to equipment.
Warns that a failure to take appropriate safety precautions could result in physical injury.
Warning
Warns of danger of electric shock.
Warning
Stinger documentation set
The Stinger documentation set consists of the following manuals, which can be found at http://www.lucent.com/support and http://www.lucentdocs.com/ins : xiv Stinger® MS+ Getting Started Guide
About This Guide
Stinger documentation set
■
■
Read me first:
– Edge Access and Broadband Access Safety and Compliance Guide . Contains important safety instructions and country-specific information that you must read before installing a Stinger unit.
– TAOS Command-Line Interface Guide . Introduces the TAOS command-line environment and shows you how to use the command-line interface effectively. This guide describes keyboard shortcuts and introduces commands, security levels, profile structure, and parameter types.
Installation and basic configuration:
– Getting Started Guide for your unit. Shows how to install your Stinger chassis and hardware. This guide shows you how to use the command-line interface to configure and verify IP access and basic access security on the unit.
■
■
■
The Getting Started Guides for Stinger models with redundant control modules describe configuration of this feature.
– The Stinger MRT Getting Started Guide describes the features and basic configuration of the trunk modules that are specific to a Stinger MRT.
– Module guides for each type of module designed for the Stinger FS, Stinger
FS+, Stinger LS, Stinger RT, Stinger CR, or Stinger MS+ an individual guide describes the module's features and provides instructions for configuring the module and verifying its status.
Configuration:
– Stinger ATM Configuration Guide . Describes how to use the command-line interface to configure Asynchronous Transfer Mode (ATM) operations on a
Stinger unit. The guide explains how to configure permanent virtual circuits
(PVCs), and shows how to use standard ATM features such as quality of service (QoS), connection admission control (CAC), and subtending.
– Stinger IP2000 Configuration Guide . For Stinger systems with the IP2000 control module, this guide describes how to integrate the system into the IP infrastructure. Topics include IP-routed switch-through ATM PVCs and RFC
2684 PVCs that terminate on the IP2000, IEEE 802.1Q VLAN, and forwarding multicast video transmissions on DSL interfaces.
– Stinger Private Network-to-Network Interface (PNNI) Supplement . Provides quick-start instructions for configuring PNNI and soft PVCs (SPVCs), and describes the related profiles and commands in the Stinger command-line interface.
– Stinger SNMP Management of the ATM Stack Supplement.
Describes Simple
Network Management Protocol (SNMP) management of ATM ports, interfaces, and connections on a Stinger unit to provide guidelines for configuring and managing ATM circuits through any SNMP management utility.
RADIUS: TAOS RADIUS Guide and Reference . Describes how to set up a TAOS unit to use the Remote Authentication Dial-In User Service (RADIUS) server and contains a complete reference to RADIUS attributes.
Administration and troubleshooting: Stinger Administration Guide . Describes how to administer the Stinger unit and manage its operations. Each chapter focuses on a particular aspect of Stinger administration and operations. The
Stinger® MS+ Getting Started Guide xv
About This Guide
Stinger documentation set
■ chapters describe tools for system management, network management, and
Simple Network Management Protocol (SNMP) management.
Reference :
– Stinger Reference . An alphabetic reference to Stinger profiles, parameters, and commands.
– TAOS Glossary . Defines terms used in documentation for Stinger units.
xvi Stinger® MS+ Getting Started Guide
Preparing for the Installation
1
Stinger MS+ overview
The Stinger MS+ chassis is designed for use in a central office environment where rack space is limited, or the local user population does not require a larger Stinger
FS+ or Stinger LS unit. The Stinger MS+ uses a mid-plane design, similar to the larger
Stinger FS+, and can be equipped with the control modules, trunk modules, LIMs, and LPMs that are used in the Stinger FS+. (For more environmental information,
see “Site specifications” on page C-4.)
The Stinger MS+ chassis
The Stinger MS+ chassis, shown in Figure 1-1, has horizontal slots in the front and
rear that engage the midplane bus. The front of the Stinger MS+ chassis has five horizontal slots for modular plug-in components and two lower bays for redundant power filters. The horizontal slots accept up to four line interface modules (LIMs) and one control module in a designated slot. Unless LIMs with integrated line protection are used, each LIM must be matched by a line protection module in a corresponding slot in the rear of the chassis. A single trunk module can also be installed a designated slot in the rear of the chassis.
Stinger® MS+ Getting Started Guide 1-1
Preparing for the Installation
Stinger MS+ overview
Figure 1-1. The Stinger MS+ (front view)
39.0cm
(15.35 in.)
4
3
2
1
MAJOR
MINOR
BITS
17.78cm
(7.0 in.)
44.9cm
(17.7 in.)
The rear of the Stinger MS+ has five horizontal slots for designated modular plug-in components. The horizontal slots accept up to four line protection modules (LPMs) and one trunk module. Access to the cooling module is also provided in the rear of the chassis.
Figure 1-2. The Stinger MS+ (rear view)
GREE
N-ACT
IVE
RED-F
AILED
4
3
CAUTION
MOVING P
ARTS
2
1
1-2 Stinger® MS+ Getting Started Guide
Preparing for the Installation
Selecting an installation site
Modular plug-in components
The Stinger MS+ chassis supports the following modular plug-in components:
■
■
The control module—A single control module is installed in the front of the chassis provides a TAOS management interface for configuration and management of the unit. The control module manages the operation of the
Stinger MS+ unit and the traffic through the unit. It also maintains information about the configuration of the unit.
LIMs—Up to four line interface modules (LIMs) are installed in the front of the chassis to provide the internal interfaces that are configured to provide service for individual DSL subscriber lines.
■
■
Line protection modules (LPMs)—Up to four line protection modules (LPMs) are installed in the rear of the chassis to provide physical connection points for the
DSL subscriber lines associated with the LIMs in the front of the chassis. The
LPMs also provide protection for the unit from transient conditions on the subscriber lines.
The trunk module—A single trunk module or trunk aggregation module (TRAM) is installed in the top slot in the back of the chassis. This can be any of the trunk modules that can be installed in the Stinger FS+. Including:
– OC3-ATM trunk module
■
■
■
– DS3-ATM trunk module
– E3-ATM trunk module
– OC3 TRAM module
– OC12-ATM trunk module
– Fast Ethernet trunk module
Power filters—Two power filters, installed in the front of the chassis, provide redundant inputs for power to the Stinger MS+.
The alarm module—A small module provides external connections for monitoring the major and minor alarm status of the unit. It also provides connections for an external BITS signal.
The cooling module—A replaceable module contains fans that circulate air through the unit, and the electronics to control and monitor their operation.
Selecting an installation site
Before you choose a location for the Stinger unit, read and follow the site and electrical requirements defined in the Edge Access and Broadband Access Safety and
Compliance Guide .
Select the setup location carefully. Keep in mind that the unit requires sufficient
equipment cabinet that is 19 inches or 23 inches (48.26cm or 58.42cm) wide (see
“Mounting the unit” on page 2-1).
Stinger® MS+ Getting Started Guide 1-3
Preparing for the Installation
Required tools and equipment
Required tools and equipment
To install and configure the Stinger hardware, you need the following tools and equipment:
■ Console terminal connection to the control module’s serial port to configure the unit
■ ASCII or VT100 console terminal (Internal Lucent number: ITE 6938) or equivalent with the following setup:
– 9600 bps
– Direct connection
■
■
■
■
■
■
■
– 8 data bits
– No parity
– 1 stop bit
– No flow control
RS-232 straight-through modem cable for connecting the console terminal or equivalent to the unit (Internal Lucent number: ITE-6801 List 22)
Antistatic wrist strap (Internal Lucent number: R-4987C)
Number 2 Phillips screwdriver
1/8-inch and 3/16-inch flathead screwdrivers
3/8-inch wrench or socket
(Optional) Ethernet LAN connection for connecting the unit to the Ethernet
(Internal Lucent number for the 7-foot (2.13m) cable: ITE-7131; for the 12-foot
(3.67m) cable: ITE-7180)
An SC fiber optic connector cleaner (Cletop, Optipop, or equivalent), if an
OC3-ATM or OC12-ATM trunk module is being installed
Preventing static discharge damage
Modules and semiconductor devices in general can be easily and permanently damaged due to electrostatic discharge during installation or removal. A person walking across a floor can generate electrostatic voltages in excess of 5000V.
Although you might not notice a discharge of less than 3500V, discharges below 100V can damage semiconductor components.
You can destroy a component without noticing any electrostatic discharge. Because these discharges have very little current, they are harmless to people.
To prevent damage to components from electrostatic discharge, always follow the proper guidelines for equipment handling and storage.
Use a wrist strap
To reduce the static potential on your body by proper grounding, wear an approved
antistatic wrist strap (Figure 1-3) when installing, removing, or handling modules, or
while handling any Lucent device containing semiconductor components.
!
Caution Correct use of an approved antistatic wrist strap is the only reliable way to prevent damage to components by electrostatic discharge from your body
1-4 Stinger® MS+ Getting Started Guide
Figure 1-3. Wrist grounding strap
Preparing for the Installation
Preventing static discharge damage
To minimize entanglement, right-handed people can wear the strap on the left hand.
Plug the other end of the wrist strap into the grounding jack provided on most Lucent
products, as shown in Figure 1-4.
Figure 1-4. Wrist strap plugged into a grounding jack
If a grounding jack is not available, use an alligator clip to connect the strap to electrical ground.
Use the following two simple tests to verify that the wrist strap is functioning properly:
■
■
Measure the resistance between the wrist strap and its grounding plug. Overall resistance between these two points must be approximately 1 megohm. If it is not, replace the strap.
Physically examine the strap for visible damage. If you see any damage, replace the strap.
Stinger® MS+ Getting Started Guide 1-5
Preparing for the Installation
Unpacking the Stinger
Remove plastics from your work area
Work areas must be kept clear of common plastics, such as the following items:
■
■
Polystyrene packing containers
Clear plastic bags
■
■
■
Plastic drinking cups
Food wrappers
Clear cellophane tape
These types of common plastic materials can carry a static charge that is not easily discharged to ground and must not make direct contact with modules or any other solid state components.
Store components properly
Protect modules immediately after removal from a chassis by placing them in their original factory packing materials. Storage in approved antistatic packaging is acceptable when factory packaging is unavailable.
!
Caution Never place unprotected modules directly on ungrounded metal shelving or on ungrounded carts without insulating surfaces.
Unpacking the Stinger
The Stinger unit is delivered in a protective shipping carton, in an electro-static protection bag, with all the ordered modules installed. Before you remove the Stinger unit from the shipping carton, check for damage. If you see any damage, follow the instructions described in your product warranty.
To avoid potential damage to the unit, Lucent Technologies recommends moving the unit to the installation site before unpacking it from the shipping carton.
!
Warning A Stinger MS+ with all components and modules installed weighs up to 66 pounds (30kg). To avoid potential injury, at least two people or a mechanical lift should be used for moving or rack-mounting a fully populated unit.
Verifying the hardware configuration
The Stinger MS+ has a midplane design that enables the control module and line interface modules in the front of a unit to connect to the line protection modules
(LPMs) and trunk module in the back.
All units are equipped with a cooling module, power filters, and an alarm module.
Other modules ordered with the unit are installed prior to shipment. Check the unit to verify that it is configured as ordered and to identify the connection points for power and data. The cable connectors for standard LPMs and the trunk module are located in the back of the chassis. Connections for the power filters, alarm monitoring, and BITS timing are located in the front of the chassis.
!
Caution Wear an antistatic wrist strap before handling any of the unit components.
This can be connected to one of two electrostatic discharge (ESD) grounding jacks
(banana jacks),
located at the bottom left corner of the front of the unit (Figure 1-5)
and in a similar location the rear of the unit (Figure 1-7).
1-6 Stinger® MS+ Getting Started Guide
Preparing for the Installation
Verifying the hardware configuration
Checking the front of the chassis
Figure 1-5 shows the front slots of a fully configured Stinger MS+.
Figure 1-5. The Stinger MS+ (front view)
Control module LIMs
4
3
2
1
MAJOR MINOR BITS
ESD Ground plug Power supplies
Alarm module
The top slot in the front of the Stinger MS+, labeled CTRL, is reserved for the control module; it cannot be used for line interface modules (LIMs). To maintain the uniformity across the Stinger product line, this slot is logically referred to by the
TAOS software as slot 8. Slots that are not occupied by modules must be masked with blank covers to ensure proper air flow through the unit.
Verifying the control module model
The Stinger MS+ unit supports three different revision 2 control modules, and a revision 2.1 control module.
The following table details the Stinger FS and Stinger FS+ control modules:
Table 1-1. Control module model designations and product codes
Model
B
C
A
A-J
E
Control module product code
STGR-CM-A
STGR-CM-A-J
STGR-CM-B
STGR-CM-C
STGR-CM-A2
Revision designation
2.0
2.0
2.0
2.0
2.1
Stinger® MS+ Getting Started Guide 1-7
Preparing for the Installation
Verifying the hardware configuration
Note Stinger units can also be equipped with the specialized IP2000 control module.
Information specific to the IP2000 control module is found in the Stinger IP2000
Configuration Guide .
Table 1-2 shows the features provided by the revision 2 and 2.1 Stinger control
modules.
Table 1-2. Control module models and features
Features STGR-
CM-A
Yes
STGR-
CM-A2
STGR-
CM-B
Yes Yes
STGR-
CM-C
Yes
Yes
No
No
Yes
No
No
Yes
Yes
No
Yes
Yes
Yes
Accepts seven alarm inputs from external devices to centralize alarm reporting.
Memory increased to 128Mb of internal synchronous dynamic RAM (SDRAM) and
32Mb of nonvolatile RAM on a PCMCIA card.
Contains an internal 56Kbps modem for dial-in remote administration.
Contains an internal Stratum 3 clock.
Note The version command displays information about the version and type of
Control module support
TAOS 9.4-185.2 introduced support for a Model E version of the control module
(STGR-CM-A2). The Model E control module utilizes enhanced chip-sets and replaces the older Model A control module. The Model E control module is identified in TAOS as hardware revision 2.1. The Stinger Model A control module
(STGR-CM-A), introduced with TAOS 9.1-142.1, is also supported by the current version of TAOS.
Control module interfaces
Figure 1-6 shows the location of the modem port, Ethernet port, serial diagnostic
port, alarm input port, and Personal Computer Memory Card International
Association (PCMCIA) slots on a model B control module.
Note See the Stinger IP2000 Configuration Guide for information about the specialized interfaces on the IP2000 control module.
1-8 Stinger® MS+ Getting Started Guide
Figure 1-6. Model B control module interfaces
Preparing for the Installation
Verifying the hardware configuration
PCMCIA slots
Internal modem port (optional)
Ethernet port
Diagnostic port
Alarm input port
10
100
FDX
ACT
The control module comes with onboard flash memory, and each PCMCIA card provides its own additional memory. The PCMCIA cards store the software and the configuration information for all modules. The system configuration is also stored in the onboard nonvolatile RAM (NVRAM).
Checking the LIMs
Several line interface modules (LIMs) are available to provide different types of line service. Line interface modules are installed in slots 1 through 4 in the front of the chassis. All LIMs that do not contain integrated protection circuitry, connect to their respective line facilities through an associated line protection module (LPM) located in the slot behind the LIM. Verify that the correct number of LIMs are installed.
Specific hardware and configuration details for each type of LIM are contained in the matching LIM guide for that module.
Stinger® MS+ Getting Started Guide 1-9
Preparing for the Installation
Verifying the hardware configuration
Checking the of the chassis
Figure 1-7 shows the back of the Stinger MS+ chassis.
Figure 1-7. The Stinger MS+ (rear view)
Trunk module
LPMs
Cooling module
GREEN-ACTIVE
RED-FAILED
3
2
4
CAUTION
MOVING PARTS
1
Ground terminal
ESD Ground plug
Unless LIMs with integrated protection circuitry are used, each LIM installed in the unit must have a corresponding LPM installed in the matching slot at the back of the unit. The top slot in the back of the Stinger MS+ is reserved for a trunk module; it cannot be used for an LPM. Slots that are not occupied by modules must be masked with blank covers to ensure proper air flow through the unit.
Verifying the trunk module
The top slot in the rear of the Stinger MS+ chassis can contain a trunk module. The trunk module supports connection to either optical or copper media, depending on the type of module supplied. This top rear slot is labeled, “TM.” To maintain the uniformity across the Stinger product line, this slot is logically referred to by the
TAOS software as slot 17.
OC3-ATM trunk modules
Figure 1-8 shows the location of the optical fiber connections on an OC3-ATM trunk
module.
1-10 Stinger® MS+ Getting Started Guide
Preparing for the Installation
Verifying the hardware configuration
Figure 1-8. OC3-ATM trunk module fiber optic connection points
Port 2
Signal
OUT
Signal
IN
Port 1
Signal
OUT
Signal
IN
OC12-ATM trunk modules
Figure 1-9 shows the location of the optical fiber connections on an OC12-ATM
trunk module.
Figure 1-9. OC12-ATM trunk module fiber optic connection points
Port 2
Signal
OUT
Signal
IN
Port 1
Signal
OUT
Signal
IN
DS3-ATM and E3-ATM trunk modules
Figure 1-10 shows the location of the coaxial connections on a DS3-ATM or E3-ATM
trunk module.
Figure 1-10. DS3-ATM or E3-ATM trunk module connection points
Port 2 Port 1
Receive from line
Transmit to line
Receive from line
Transmit to line
TRAM modules
Figure 1-11 shows the location of the DS3 or E3 coaxial connections and the OC3
optical fiber connections on a TRAM module. TRAM modules are also available that support only OC3 connections. See the Stinger Trunk Aggregation Module (TRAM) Guide for details.
Stinger® MS+ Getting Started Guide 1-11
Preparing for the Installation
Verifying the hardware configuration
Figure 1-11. TRAM module connection points
Port 6
Rcv from
Xmt to line line
Port 5
Rcv from line
Xmt to line
Port 4
Rcv from line
Xmt to line
Port 3
Rcv from
Xmt to line line
Port 2
Xmt to line
Port 1
Rcv from
Xmt to line line
Rcv from line
Fast Ethernet Trunk module
Figure 1-12 shows the location of the two RJ-45 10Base-T/100Base-T Ethernet
connectors. See the Stinger Fast Ethernet Trunk Configuration Guide for details.
Figure 1-12. Fast Ethernet trunk module connection points
Port 1 Port 2
Checking the LPMs
Several line protection modules (LPMs) are available to provide the correct number or connections for their associated LIMs. Line protection modules are installed in slots
1 through 4 in the back of the chassis. All LIMs connect to their respective line facilities through an associated line protection module. Verify that the correct number of LPMs are installed. Specific hardware details for each type of LPM are contained in the Stinger Line Protection Module (LPM) Guide .
1-12 Stinger® MS+ Getting Started Guide
Installing a Stinger MS+
2
Before you begin
Verify that you have completed the following tasks:
■
■
Selected the installation site
Unpacked the Stinger unit
■
■
Gathered the tools and equipment needed for installation
Checked the module configuration in the unit
!
Warning Before installing the Stinger hardware, be sure to read the safety instructions in the Edge Access and Broadband Access Safety and Compliance Guide . See
Appendix C, “Safety-Related Electrical, Physical, and Environmental Information,”
for information specific to your product.
Mounting the unit
Stinger MS+ units are delivered with mounting brackets installed on the chassis.
Three Models can be ordered with brackets for different rack-mounting requirements.
■ STGRMSP19—for mounting in a 19-inch (48.26cm) equipment rack
■
■
STGRMSPETSI—for mounting in a a 51.5cm (20.28-inch) European
Telecommunications Standards Institute (ETSI) equipment rack
STGRMSP23— for mounting in a a 23-inch (58.42cm) equipment rack
Note The rack-mount spacing meets IEC 297-2 and ANSI/EIA-RS-310-C standards.
Stinger® MS+ Getting Started Guide 2-1
Installing a Stinger MS+
Mounting the unit
Figure 2-1 displays the available Stinger MS+ models with their mounting brackets.
Figure 2-1. Stinger MS+ chassis models for rack mounting
STGRMSP19
4
3
2
1
MAJOR MINOR BITS
!
18.2 in.
(46.51cm)
STGRMSPETSI
4
3
2
1
MAJOR MINOR BITS
20.28 in.
(51.5cm)
STGRMSP23
4
3
2
1
MAJOR
MINOR
BITS
22.3 in.
(56.674cm)
The procedure for installing the unit into a cabinet requires that you supply a minimum of four cross-head screws of the appropriate size to support the unit in the cabinet.
Warning Installing a rack-mounting a unit with all components installed requires more than one installer. A fully populated Stinger MS+ weighs up to 30kg (66 pounds).
2-2 Stinger® MS+ Getting Started Guide
Installing a Stinger MS+
Connecting cables to a Stinger unit
To rack-mount a Stinger unit into an equipment cabinet:
1 Carefully raise the unit to the appropriate installation height.
2 Align the screw holes on the mounting bracket with the screw holes on the equipment cabinet.
3 Using a number 2 Phillips screwdriver, install cross-head screws of the appropriate size through the mount bracket on the unit into the mounting bracket on the equipment cabinet.
Connecting cables to a Stinger unit
Once the Stinger unit is set up in the desired location, connect the unit to the local facilities or to its frame access points by attaching the appropriate cables to the LPMs.
Connect the Stinger unit to the ATM network by attaching the copper or fiber connections to the trunk modules.
Connecting to the LPMs
LPMs provide physical connections for the DSL lines supported by their associated
LIMs. LPMs are available with 50-pin connectors that support 24, 48, or 72 port
LIMs. An LPM is also available with 64-pin connectors that contains internal splitters to support up to 48 ports of ADSL-over-POTS service. For specific information about the connectors, pinouts, and cables associated with your LPMs, see the Stinger Line
Protection Module (LPM) Guide .
Securing the connectors
Connections to 50-pin connectors can be secured by three mechanisms shown in
Figure 2-2. It is recommended that you use these mechanisms to make the
connections as secure as possible.
■ An anchor screw on the far end of the connector can be screwed into a fitting on the LPM. Some connectors can use anchor screws at both ends of the connector.
■
■
A locking tab under the cable side of the connector automatically secures the connector upon installation.
A nylon cinch-tie can be used secure the cable end of the connector to a tie-down fitting on the LPM. If the connectors you are using have a slot to accept the connector locking tab, use of a nylon cinch-tie is optional.
Stinger® MS+ Getting Started Guide 2-3
Installing a Stinger MS+
Connecting cables to a Stinger unit
Figure 2-2. LPM 50-pin connector
Locking tab
Locking tab slot
Cinch-tie
Anchor screw
Note Connections for 64-pin connectors are secured by anchor screws on the top and bottom of each connector.
Connecting the subscriber lines
In the rear of the chassis, cables are routed toward the left, as shown in Figure 2-3, to
allow for removal and replacement of the cooling module.
Use the following procedure to connect the cables to the line ports of an LPM with
50-pin RJ-21 connectors, installed in the Stinger MS+ unit:
1 Carefully insert the on the line connections of the LPMs in the Stinger MS+ unit,
Figure 2-3. Connecting to LPMs in a Stinger MS+ unit
GREE
N-ACT
IVE
RED-F
AILED
3
2
1
4
CAUT
ION
MOVING
PARTS
2-4
Note
See Figure 2-2 for details of the connector locking tab, anchor screw, and cable
cinch-tie.
2 Push the cable connectors onto the chassis connectors until each locking tab is engaged.
3 Tighten the anchor screw on each cable connector.
Stinger® MS+ Getting Started Guide
Installing a Stinger MS+
Connecting cables to a Stinger unit
4 Secure the cable connectors to the chassis with a cable cinch-tie around the connectors and through the security fixtures on the left side of the line connectors on the chassis. (Optional, if your cable connectors have a slot to engage the locking tab.)
Connecting the trunk modules
The trunk module cables are either coaxial (for DS3 or E3) or fiber optic (for
OC-3/STM-1 optical or OC-12/STM-4 optical).
Optical trunk module connections
The OC3-ATM and OC12-ATM trunk modules require duplex SC fiber optic cable.
Bind excess cable lengths in a figure-eight pattern. Do not wind excess cable into circular coils.
Note Clean any fiber optic cables prior to connecting them.
To connect the cables to an OC3-ATM or OC12-ATM trunk module, carefully insert the head of each cable into a connector on the trunk module. An example of this
connection on an OC3-ATM trunk module is shown in Figure 2-4.
Figure 2-4. Connecting an OC3-ATM trunk module
3
2
4
CAUTION
MOVIN
G PAR
TS
1
DS3-ATM or E3-ATM trunk module connections
Connect the DS3 or E3 line to the RX LN and TX LN connectors on a DS3-ATM or
E3-ATM trunk module, using two 75-ohm coaxial cables (RG 59/U).
To configure a redundant DS3 or E3 connection, connect the BY connectors on the primary trunk module to the LN connectors on the backup trunk module as shown
in Figure 2-5. If the primary port fails, the traffic is switched over to the secondary
module’s port.
Stinger® MS+ Getting Started Guide 2-5
Installing a Stinger MS+
Control module connections
Figure 2-5. Connecting a DS3-ATM or E3-ATM trunk module
4
CAUT
ION
MOVIN
G PAR
TS
3
2
1
Inform your service provider that the equipment is connected, so they can activate the line.
Control module connections
The control module provides the following ports and connections:
needed to connect the Stinger unit to a workstation or a console. See Appendix B,
“Cables and Connectors,” for console cable pinouts.
Each control module supports three types of network management connections for communication with the Stinger unit:
■ A female DB-9 serial port, labeled DIAG PORT. This connector is used with an
RS-232 shielded straight-through cable (ITE6801), to a terminal for basic
configuration. See “Serial connection to a console” on page 5-2, for details about
this connection.
■
■
It can also be connected to an external modem for dial-in administrative access.
See “Backup management with an external modem” on page 5-3, for details of
this connection.
A female DB-15 connector labeled ALARM INPUT. This connector provides access for connecting of up to 7 pairs of wires that monitor the alarm condition of
An RJ-11 jack that provides a connection for an external analog telephone line to
Note The optional internal modem is only available on Revision 2 control module models B and C.
■ An RJ-45 connector that provides a 10BaseT or 100BaseT Ethernet network connection through unshielded twisted pair (UTP) cable. This connection can provide access to an administrative network, and is not designed for end-user
data. See “Network connection to a workstation console” on page 5-2, for details
of this connection.
2-6 Stinger® MS+ Getting Started Guide
Installing a Stinger MS+
System clocking
System clocking
The control module has four possible timing sources:
■ External. The Stinger unit can accept timing from a T1 line, or a building interoffice timing source (BITS) clock, connected to the alarm module BITS
■
■
■
Trunk. The Stinger unit can accept timing from an OC3, DS3, or E3 line clock.
LIMs. The Stinger unit can accept timing from an ADSL or SDSL line clock.
Internal clock source. If the selected clock sources fail, the system is automatically reconfigured so that it is synchronized with the control module’s internal clock.
The T1 or BITS timing inputs work with DS1 timing references that comply with the
ANSI T1.102 standard. The system timing is configured through the TAOS command-line interface. For detailed information about the profile and options that
configure system clocking, see “Configuring system clocking” on page 5-14.
Alarm monitoring
There are two groups of alarm connections on the Stinger MS+. One group, on the chassis alarm module, communicates the major or minor alarm status of the Stinger
MS+ unit to an external system or status indicator. The Stinger MS+ can use another group of connections on a revision 2 or revision 2.1 control module to monitor and report the alarm status of up to seven other external systems.
Connecting to monitor Stinger unit alarm status
The alarm module on the front of the unit, in the lower right corner, contains three sets of connectors for connecting the following:
■ Major alarms
■
■
Minor alarms
External BITS clock
The alarm module along with its BITS and alarm connections is shown in Figure 2-6.
Figure 2-6. Stinger MS+ alarm module
MAJOR MINOR BITS
The alarm module contains alarm terminals for monitoring the status of the Stinger
MS+ unit. The Stinger MS+ can monitor itself for major and minor alarm conditions and illuminate appropriate status lights on the control module. In addition, you can connect audio and visual alarms to the normally open or normally closed alarm relay contracts of the alarm terminals to remotely monitor the unit for these conditions.
Stinger® MS+ Getting Started Guide 2-7
Installing a Stinger MS+
Alarm monitoring
The alarm-relay contacts operate during loss of power, during hardware failure, or whenever the Stinger unit is being reset, such as during its power-on self test (POST).
A normally closed (NC) or normally opened (NO) contact is used in combination with the common (COM) contact to monitor the normally opened or normally closed
operation of the major or minor alarm relays. (See Figure 2-6.)
The gauge of the wire you use to connect to the Stinger alarm relay must be based on the current flow of the circuit that the relay is attached to and the capacity of the alarm relay. Because the Stinger alarm relay can carry a maximum of 2 amps, 18
AWG to 20 AWG (0.8mm² to 0.5mm²) wire is adequate.
To connect a remote alarm:
1 Locate the appropriate terminal for the alarm connection you want to make.
2 Using a 1/8-inch flathead screwdriver, loosen the screws on the Major and Minor normally opened (NO) or normally closed (NC) and common (COM) terminals.
3 Using 18AWG to 20AWG (0.8mm² to 0.5mm²) solid or stranded wire, strip the ends of the wire approximately 1/4 inch (6.35 mm).
4 Insert the wire leads into the appropriate positive terminal connector and its return.
5 Using a 1/8-inch flathead screwdriver, tighten the screws on the positive and return terminals to secure the leads.
Connecting a Stinger unit to monitor the alarm status of other devices
Revision 2 and revision 2.1 control modules have a DB-15 connector that can accept connections to monitor the alarm status of up to seven external devices. The connection for each external device consists of a pair of 24-gauge to 28-gauge connectors. One connector supplies ground, and the other senses the status of the remote alarm by applying 3.3Vdc, which draws less than 10mA of current through the closed contacts of the alarm relay on the remote device. For the pinout
arrangement of these connectors on the DB-15 connector, see “Alarm input port pinouts” on page B-2.
Connections from the control module
To connect to a remote device:
1 Using a male DB-15 connector, connect a 15-lead cable to the ALARM INPUT connector of the control module. One lead is unused.
2 Run one pair of leads to the alarm connectors of each remote device to be
monitored by the Stinger unit, as shown in Figure 2-7.
2-8 Stinger® MS+ Getting Started Guide
Installing a Stinger MS+
What’s next
Figure 2-7. Connecting to the alarm input port
Alarm input port
MINOR
BITS
Cable
(15 leads)
Alarm connections
1
2
3
4
5
6
7
The alarm relays of external devices can be either normally opened or normally closed. The Stinger unit can be configured to sense an alarm condition for the opening of a normally closed relay, or the closing of a normally open relay. For information on the configuration of these parameters, see the information about
SNMP alarm support for input relay alarms in the Stinger Administration Guide .
What’s next
When you finish physically installing the Stinger unit you can proceed to Chapter 3,
“Determining the Operating Status.”
Stinger® MS+ Getting Started Guide 2-9
Determining the Operating
Status
3
Before you begin
Before you begin, verify that the following tasks are complete:
■
■
■
■
■
■
Set up the Stinger hardware (as either a free-standing or rack-mounted unit)
Connected cables and console terminal to the Stinger unit
Set up the workstation to configure the Stinger unit
Connected the workstation to the Stinger unit
(Optional) Connected the system clock source
(Optional) Connected the remote alarms
Connecting power to a Stinger unit
!
Caution Before connecting power, see the Edge Access and Broadband Access Safety and
Compliance Guide for safety instructions and circuit regulatory information.
Warning Verify that the power is off or disconnected at the source before beginning this procedure.
To connect the unit to dc power:
1 Verify that the correct power source is available for the Stinger unit.
2 Verify that the dc power cables comply with national standards and specifications as described in IEC 60950 and are terminated in number 10 ring lugs.
3
Figure 3-1 shows how to connect power to the Stinger unit. Be sure to attach a
power cable to each set of power connectors as follows. Both power cables must be connected at all times when the unit is in operation.
– Verify that the power switch on the power filters is set to the OFF position.
– Locate the number 10 studs on the back of the unit.
Stinger® MS+ Getting Started Guide 3-1
Determining the Operating Status
Turning on power to a Stinger unit
– Using a number 2 Phillips screwdriver, remove the two screws that secure the protective cover over the studs. Then remove the protective cover.
– Using a 3/8-inch wrench or socket, remove the top locking nut from each of the two studs (labeled -48V and RTN). Do not remove the bottom locking nut.
– Install the ring lugs onto the appropriate posts.
Note You can optionally ground the chassis to the enclosure by attaching dual mount ground lugs to the ground terminal on the back of the unit. Do not remove the ground lugs.
– Reinstall the locking nut onto each post, then use a 3/8-inch wrench or socket to tighten the nut.
– Reinstall the protective cover with the two screws.
Figure 3-1. Connecting the power filters
Protective cover
Power filter A Power filter B
Turning on power to a Stinger unit
!
Caution Do not turn on power to a Stinger unit without a control module installed in the chassis. Starting up a unit with no control module installed can damage hardware components.
To turn on power to the unit, press the power switch on each power filter to the
ON ( | ) position.
All Stinger status lights, except the MASTER light, momentarily turn ON just after startup.
On the control module, the MAJOR status light turns ON at startup. It then starts blinking slowly while the control module runs its POST in the boot loader. It continues to blink while the control module loads its operational code from the
PCMCIA flash card. If the control module successfully loads its operational image from the PCMCIA flash card and again passes POST, the MAJOR status light turns
OFF. If the MAJOR status light continues to blink, it indicates a failure.
3-2 Stinger® MS+ Getting Started Guide
Determining the Operating Status
Status lights
After startup, all six TRUNK STATUS lights and the MINOR status light turn OFF.
Then after the system comes up, each light monitors a particular status as described in the next section.
Status lights
The status lights on the modules in the Stinger unit indicate the operating status of each module.
Control module status lights
Figure 3-2 shows the locations of the control module status lights.
Figure 3-2. Control module status lights
Ethernet status lights
10
100
FDX
ACT
Alarm status lights
TRUNK STATUS lights
MASTER status light
All control module status lights except the MASTER light momentarily turn ON just after startup, and all six TRUNK STATUS lights turn OFF. After the system starts up,
each light monitors a state as described in Table 3-1.
Stinger® MS+ Getting Started Guide 3-3
Determining the Operating Status
Status lights
The status lights in the upper portion of the control module indicate the status of the
Ethernet interface. The status lights at the bottom of the control module indicate the status of the control module and the trunk modules.
Note The upper portion of the control module is on the left side, and the lower portion of the control module is on the right side, when the control module is installed in the MS+ chassis.
Table 3-1. Status lights on the control module
Status light
Color Condition
10
100
FDX
ACT
Green
Green
Green
Green
ON
ON
ON
ON
MAJOR Amber ON or blinking
Indicates
10BaseT Ethernet activity has been detected.
100BaseT Ethernet activity has been detected.
Full-duplex mode is active.
MINOR Amber ON or blinking
Activity detected on the Ethernet interface.
The control module has detected a major alarm. For information about configuring major alarms, see the Stinger Administration
Guide .
The MAJOR status light turns ON at startup. It then starts blinking slowly while the control module runs its POST in the boot loader. It continues to blink while the control module loads its operational code from the PCMCIA flash card. If the control module successfully loads its operational image from the PCMCIA flash card and again passes POST, the MAJOR status light turns OFF. If the MAJOR status light continues to blink, it indicates a failure.
The control module has detected a minor alarm. For information about configuring minor alarms, see the Stinger Administration
Guide .
The MINOR status light is ON at startup. It remains ON until the control module passes all
POST tests. It then stays OFF until a minor alarm occurs.
If the control module fails POST, the MINOR status light remains ON.
3-4 Stinger® MS+ Getting Started Guide
Determining the Operating Status
Status lights
Table 3-1. Status lights on the control module (continued)
Status light
Color Condition Indicates
TRUNK
STATUS
Green ON
Green blinking
The six TRUNK STATUS lights indicate the status of trunk module ports attached through the backplane to the control module. Only the first 3 lights are used on Stinger MS+ units to refer to ports 1, 2, and 3, if present, on the trunk module in the rear of the chassis.
If a TRUNK STATUS light is ON, the port is fully operational.
The port is installed but not operating.
TRUNK
STATUS
TRUNK
STATUS
Green OFF
MASTER Green ON
The trunk module port corresponding to the light is not present on the installed trunk module, or the trunk module is not installed.
Indicates that the control module is the master
(primary). On the single control module in the
Stinger MS+ unit, this light is always lit.
LIM status lights
For detailed information about the status lights on each LIM and their expected behavior, see the module guide for the specific LIM in question.
Trunk module status lights
For detailed information about the status lights on each trunk module and their expected behavior, see the module guide for the specific trunk module in question.
Fan status light
In the rear of the chassis, on the fan unit, a status light indicates the operating status
of the fans. The status indicted by this light is described in Table 3-2.
Table 3-2. Fan status light
Status light color
Indicates
Green
Red
The fan has power and is operating normally.
The fan is in a fault state.
Stinger® MS+ Getting Started Guide 3-5
Determining the Operating Status
What’s next
What’s next
Once the hardware installation is complete and the Stinger unit is powered up, you can begin basic configuration as described in the following chapters, or download a previous software configuration.
3-6 Stinger® MS+ Getting Started Guide
Stinger Operational Overview
4
Stinger MS+ operation as a DSL access multiplexer . . . . . . . . . . . . . . . . . . . . . . 4-1
Stinger MS+ operation as a DSL access multiplexer
A Stinger MS+ unit typically operates as an ATM switch-through digital subscriber line access multiplexer (DSLAM). It switches data from multiple xDSL subscribers
onto a high-speed ATM backbone. Figure 4-1 shows this type of operation.
Figure 4-1. Example of DSLAM operations
U P S T R E A M
DSL CPE
ATM
DSL Terminator
D O W N S T R E A M
Note A Stinger MS+ unit equipped with an IP2000 control module can also process
IP traffic. With the IP2000, a the unit typically routes IP traffic from subscribers to the
IP infrastructure across a Gigabit Ethernet interface, and forwards IP multicast video transmissions to xDSL multicast clients. Configuration for this type of operation is described in the Stinger IP2000 Configuration Guide .
Stinger® MS+ Getting Started Guide 4-1
Stinger Operational Overview
Stinger ATM switching overview
Stinger ATM switching overview
A Stinger unit receives ATM cells on a link that is identified by a pair of unique attributes. These attributes are known as the virtual path identifier (VPI) and the virtual channel identifier (VCI). The Stinger unit switches the cells from an incoming link to an outgoing link, based on the VPI and VCI attributes of each link. The connection between these links is usually a static configuration entered by an administrator, although a more dynamic method of forming link connections, known as a private network-to-network interface (PNNI), might be used.
This guide covers only basic installation information and configuration of the control module. More detailed information about configuring the unit to support ATM traffic can be found in the Stinger ATM Configuration Guide and the Stinger Private
Network-to-Network Interface (PNNI) Supplement.
Stinger configuration overview
Before you configure a Stinger MS+ unit, create a diagram that illustrates how the unit will interoperate with your current network configuration. Creating a comprehensive network diagram helps prevent problems during installation and configuration, and can help in troubleshooting any problems later.
Stinger MS+ configuration tasks include the following:
■
■
■
■
■
Configuring the control module
Configuring the DSL line interface modules (LIMs)
Configuring the trunk module
Defining ATM traffic contracts
Configuring connections, either locally or through RADIUS
Control module configuration
The control module has an RS-232 serial port (labeled DIAG PORT) and a
10/100BaseT Ethernet port. The serial port is for system management from a local workstation. It is also the standard port for error output, stack traces, and messages in the event of a system crash. Until you have configured an IP address on the Ethernet interface of the control module, you must use a local terminal or workstation connected to the serial port of the control module to configure the Stinger MS+ unit.
There is no other way to log into the unit to perform the initial configuration.
The Ethernet port on the control module is intended for light data and management traffic. Once you have assigned an IP address, you can Telnet into the unit from a local host and download configuration files from a TFTP server to the Stinger system.
A Stinger unit has a range of options for configuring IP and for protecting the unit from unauthorized administrative access.
Line interface module (LIM) configuration
A Stinger unit supports any combination of ADSL, HDSL2, SHDSL, IDSL, or SDSL
ATM modules. Each port on a LIM has a variety of configuration options, including line rates and bandwidth. The way you configure each line depends on your connectivity needs.
4-2 Stinger® MS+ Getting Started Guide
Stinger Operational Overview
Stinger management features
A T1 or E1 LIM is also available to provide up to 8 or 24 DS1 or E1 lines for traffic exiting the network (egress traffic), when the bandwidth of a DS3, E3, or OC3 trunk module is not needed.
For specific information about LIM configuration, see the module guide for the desired LIM.
Trunk module configuration
The Stinger MS+ unit supports a single trunk module or TRAM modules. Trunk modules with OC3-ATM, DS3-ATM, or E3-ATM interfaces are supported. OC3 TRAM modules with DS3, E3, or only OC3 interfaces are also supported. You can set up the unit to use the full trunk-side bandwidth actively, or you can designate one or two of the trunk ports as spares, to be used only if another trunk port fails.
The trunk module can connect the Stinger unit to another ATM switch. The line configuration includes settings that must match between the local and far-end switch interfaces.
For specific information about trunk module configuration, see the module guide for the desired trunk module.
System clocking modes
The Stinger unit requires a clock source for its timing subsystem. By default, it uses a built-in 8kHz clock on the control module as its timing source. You can configure the system to take its clock source from a trunk port or from an external building interoffice timing source (BITS) clock connected to the Stinger unit.
For detailed configuration information, see “Configuring system clocking” on page 5-14.
Stinger management features
To enable you to configure the system and monitor its activity, Stinger units support profiles, commands, and status windows in the command-line interface. Stinger units also support SNMP management, RADIUS profiles, and the ability to upload (back up) and download software and configuration files over TFTP or serial connections.
A Stinger system provides several permission levels to control the management and configuration functions that are accessible in the command-line interface. For information about User profiles and other management features, see the Stinger
Administration Guide .
For an introduction to the command-line interface and its shortcuts, see the The TAOS
Command-Line Interface Guide .
Using the command-line interface
The Stinger command-line interface provides access to commands, profiles, and status windows. You must use the command-line interface to provide the initial system and IP configuration for the unit, although you can choose to perform subsequent configuration tasks remotely through a Telnet session or SNMP, or by downloading configuration files using TFTP.
Stinger® MS+ Getting Started Guide 4-3
Stinger Operational Overview
Stinger management features
Onboard flash memory and software updates
You can perform software upgrades of the onboard flash memory in the field. You upgrade the Stinger unit by accessing it locally through its serial (DIAG) port and downloading software upgrades from a TFTP server. For details, see the Stinger
Administration Guide .
SNMP support
In addition to managing a Stinger unit by means of the command-line interface, you can manage the unit by using an SNMP management station such as the
NavisAccess™ product. A Stinger unit can generate SNMP traps (notifications) to indicate alarm conditions, and it relies on SNMP community strings to implement
SNMP security.
For information about using SNMP with Stinger units, see the Stinger Administration
Guide and the Stinger SNMP Management of the ATM Stack Supplement .
RADIUS support
You can use RADIUS to store user profiles for ATM circuits and terminating connections. The RADIUS server must be compliant with vendor-specific attributes
(VSAs), as defined in RFC 2138. To use RADIUS, you must also configure the Stinger unit to communicate with the RADIUS server.
For information about configuring and using RADIUS, see the TAOS RADIUS Guide and Reference .
Tracking system activity
A Stinger unit supports many commands for monitoring system activity. To display the commands that are available with the permission settings in the current User profile, enter the help (or ?
) command. The following example shows the commands available for the admin login. The left column shows command names, and the right column shows the command class , which determines the permissions required to use the command.
admin> ?
? ( user )
arptable ( system )
auth ( user )
callroute ( diagnostic )
clear ( user )
clock-source ( diagnostic )
clr-history ( system )
connection ( system )
date ( update )
debug ( diagnostic )
delete ( update )
device ( diagnostic )
dir ( system )
dircode ( system )
ether-display ( diagnostic )
fatal-history ( system )
format ( code )
fsck ( code )
4-4 Stinger® MS+ Getting Started Guide
Stinger Operational Overview
What’s next
get ( system )
hdlc ( system )
[More? <ret>=next entry, <sp>=next page, <^C>=abort]
For details about each command, see the Stinger Reference . For more information about command help, see the The TAOS Command-Line Interface Guide .
Verifying software and control module versions
The version command displays the version of TAOS that is currently running in the
Stinger unit and also displays the version and type of control module installed.
For example a model E revision 2.1 control module provides the following response to the version command: admin> version software version 9.7.0
* * * 9_7_0/stngrcm2 <tststngr> Jun 30 2004 04:09 * * *
Hardware revision: 2.1 Model E
Status windows
The command-line interface supports several status windows that focus on different aspects of system activity (such as connection status and log messages). The windows provide a great deal of read-only information about what is currently happening in the unit. To display a status window, enter the Status command: admin> status
The system prompt moves to just below the status window. To close the status window, enter the command again: admin> status
If the system prompt is not visible below the status window, press Escape to display it.
Note Stinger configuration settings are stored in onboard flash memory, and must be backed up to a TFTP host whenever changes are made. For details about backing up and restoring the Stinger configuration, see the Stinger Administration Guide .
What’s next
When you have planned your network, you are ready to configure the Stinger unit.
You can perform configuration tasks in any order you want. Table 4-1 shows where
to look for the information you need.
Table 4-1. Location of configuration information
Configuration task
Establish a serial connection
Set up basic access security
Configure IP
Configure the unit to use
RADIUS
Location
“Serial connection to a console” on page 5-2
“Restricting administrative access” on page 5-7
“Providing a basic system IP configuration” on page 5-9 and the
Stinger IP2000 Configuration Guide
TAOS RADIUS Guide and Reference
Stinger® MS+ Getting Started Guide 4-5
Stinger Operational Overview
What’s next
Table 4-1. Location of configuration information (continued)
Configuration task Location
Configure the unit’s LIMs
Checking LIM port status
Configure the unit’s trunk lines Trunk module guide for the desired module
Checking trunk status Trunk module guide for the desired module
Define ATM traffic contracts
LIM guide for the desired module
LIM guide for the desired module
Configure ATM circuits
Configure virtual path switching
Stinger ATM Configuration Guide and the Stinger
Private Network-to-Network Interface (PNNI)
Supplement
Stinger ATM Configuration Guide , the Stinger Private
Network-to-Network Interface (PNNI) Supplement , and the Stinger IP2000 Configuration Guide
Stinger ATM Configuration Guide and the Stinger
Private Network-to-Network Interface (PNNI)
Supplement
Check details about parameters and commands
Stinger Reference Guide
Use SNMP with the unit Stinger Administration Guide and the Stinger SNMP
Management of the ATM Stack Supplement
Stinger IP2000 Administration Guide Configure IP2000 gigabit
Ethernet interfaces
Configure login permissions Stinger Administration Guide
Stinger Administration Guide Back up the system configuration
Test lines and ports Stinger Administration Guide
4-6 Stinger® MS+ Getting Started Guide
Configuring the Control
Module and System Timing
5
Control module configuration overview
The control module controls the operations of the Stinger unit. It manages and boots the LIMs, maintains a central repository of the unit’s configuration, performs call control and processing operations, and manages all centralized functions, such as
SNMP access or communication with a RADIUS server.
Control module configuration includes the following tasks:
■ Connecting a console workstation to the serial port on the control module of the
Stinger unit
■
■
■
■
Logging into the Stinger unit
Changing default security settings to protect the unit
Configuring IP to make the system accessible by Telnet, SNMP, and Ping
Configuring RADIUS access (if appropriate)
Stinger units equipped with the IP2000 control module can also be configured to support termination and aggregation of RFC 2684 Asynchronous Transfer Mode
(ATM) PVCs, IGMP multicast v1/v2 and IEEE 802.1Q tagged virtual local area networks (VLANs). Information about these capabilities is contained in the Stinger
IP2000 Configuration Guide . However, the following information will allow you to perform basic administrative configuration for IP2000 control modules.
Administrative connections
The serial port the control module in a Stinger MS+ unit is used for initial configuration from a console device. The port can also be configured to connect to a
Stinger® MS+ Getting Started Guide 5-1
Configuring the Control Module and System Timing
Administrative connections modem to provide dial-in administrative access to the unit. Revision 2 control module models B and C contain an internal modem, configured by default for autoanswer. On these models, you need only to connect the RJ-11 modem jack to the telephone line and then call in to the Stinger unit for an administrative connection.
Once the Stinger unit has been configured with an IP address, it can be reached on the IP network via a Telnet connection. The following information provides details of these connection methods.
Serial connection to a console
Figure 5-1 shows a cable connection from a Stinger MS+ to a console terminal.
Figure 5-1. Serial management connection to a Stinger MS+
To console serial port
Diagnostic port
MAJO
R
MINOR
BITS
RTN
TN
-48VD
C
-48VDC
-48VD
C
-48VDC
To connect the console terminal to the Stinger unit, connect one end of a shielded straight-through cable to the diagnostic port (DIAG PORT) on the control module.
Then connect the other end of the cable to the serial port on the console device.
The diagnostic port on the control module consists of a female DB-9 connector.
Examine the serial connector of your PC or dumb terminal to ensure that your shielded straight-through cable has the proper connectors. If needed, you can use
DB-9-to-DB-25 converters or gender converters to complete this connection.
See Appendix B, “Cables and Connectors,” for detailed information about the pinouts
on the console serial port.
Network connection to a workstation console
After the IP address of the Stinger unit has been configured, and the unit has been connected to a network, an administrative Telnet connection can be established
through the network. Figure 5-2 shows an Ethernet network connection from the
Stinger unit to the management workstation.
5-2 Stinger® MS+ Getting Started Guide
Figure 5-2. Ethernet connection
Configuring the Control Module and System Timing
Administrative connections
Workstation
Ethernet port
Ethernet port
MAJO
R MINOR
BITS
RTN
-48VD
C
TN
-48VDC
Router
-48VD
C
RTN
-48VDC
To connect a management workstation to the Stinger unit using an indirect Ethernet connection:
1 Connect one end of the Ethernet cable to the Ethernet RJ-48 port on the control module.
2 Connect the other end of the Ethernet cable to the local LAN.
3 Ensure that the management workstation has connectivity to the LAN on which the unit resides.
4 Ensure the Ethernet transceivers are connected properly to the network.
Connecting a dial-in backup management connection
Lucent Technologies recommends that you provision dial-up or some other access to each unit for backup administrative access. Dial-up access to a Stinger unit equipped with a revision 1 control module, a revision 2 model A control module, or a revision
2.1 model E control module, requires a properly configured external modem connected to the DIAG port on the control module. Revision 2 control module models B and C are equipped with an internal modem to support this type of backup management connection.
Backup management with an external modem
To configure a backup administrative connection with an external modem, connect the modem to the Stinger diagnostic port (DIAG PORT) with a null modem
(crossover) cable. In addition, you might need a DB-25-to-DB-9 adapter. Figure 5-3
shows the backup administrative connection with a modem to the Stinger unit.
Stinger® MS+ Getting Started Guide 5-3
Configuring the Control Module and System Timing
Administrative connections
Figure 5-3. Backup administrative connection with a modem to the Stinger MS+ unit
To modem
Diagnostic port
MAJO
R
MINOR
BITS
Null modem cable
RTN
TN
-48VD
C
-48VDC
RTN
-48VD
C
-48VDC
The modem you use to connect to the Stinger unit must be configured as follows:
■ Dumb mode. Dumb mode causes the modem to ignore data on the receive data
(RD) lead.
■
■
■
Ignore on-to-off transitions of the data-terminal ready (DTR) lead.
Auto answer enabled.
8 bits, 1 stop bit, and no parity.
Configure the following AT commands on the modem: ats0=1 ate0 at&c0 atq1 at&w0 at&y0
Answer automatically after one ring.
No echo (required).
Assert the data carrier detect (DCD) signal.
Result codes are not sent.
Store in nonvolatile RAM (NVRAM) as profile 0 (zero).
Use stored configuration from profile 0 (zero) on startup.
Modem country codes
You can configure the internal modem in a revision 2 control module to support the national regulations of telephone companies in specific countries. If the modem supports the country that you have specified, the system programs the modem with the settings necessary for that country. The country-code parameter in the modem profile, shown here with its default value, is used for this setting.
[in MODEM/{ shelf-1 first-control-module 3 }] physical-address* = { shelf-1 first-control-module 3 } country-code = unitedstates
The cmmodemShowCurrentCountry debug command displays the country code that is currently configured in the modem.
5-4 Stinger® MS+ Getting Started Guide
Configuring the Control Module and System Timing
Administrative connections
The cmmodemShowCountries system-level command displays a list of countries that the modem installed in the revision 2 control module supports. The following is a sample output of this command: admin> cmmodemShowCountries
The country codes supported by this modem are:
0, Japan
9, Australia a, Austria f, Belgium
16, Brazil
26, China
31, Denmark
3c, Finland
3d, France
42, Germany
46, Greece
53, India
57, Ireland
59, Italy
61, Korea
6c, Malaysia
73, Mexico
7b, Netherlands
82, Norway
8a, Poland
8b, Portugal
9c, Singapore
9f, South Africa a0, Spain a5, Sweden a6, Switzerland b4, United Kingdom b5, United States fd, unknown fe, Taiwan
For additional information about this parameter and these commands, see the
Stinger Reference .
Backup management with an internal modem
Revision 2 control module models B and C are equipped with an internal modem.
This modem is configured by default to automatically answer any incoming calls. For this reason, you need only connect the telephone line to the RJ-11 jack on the face of
the control module. Figure 5-4 shows a connection for an internal modem.
Stinger® MS+ Getting Started Guide 5-5
Configuring the Control Module and System Timing
Logging into the control module
Figure 5-4. Connection for internal modem
Modem port
MAJO
R
MINOR
BITS
RTN
-48VD
C
P.O.T.S.
(plain old telephone service) cable
Use the Modem profile to set the autoanswer configuration of this modem. Following is a sample of this profile with its default setting:
[in MODEM/{ shelf-1 first-control-module 3 }] physical-address* = { shelf-1 first-control-module 3 } auto-answer = on
The auto-answer parameter has three valid settings:
Setting on off primary-only
Specifies
The internal modem automatically answers any incoming call and attempts to negotiate modem protocols with the caller.
The internal modem ignores incoming calls.
Not used in the Stinger MS+ unit.
Note In Stinger units with redundant control modules, the internal modem automatically answers incoming calls only if the control module is the primary control module for the
Stinger unit. When the control module is set as the secondary control module, the modem ignores incoming calls. This setting allows redundant controllers to share a single telephone line.
Logging into the control module
To configure the unit initially, or after clearing its NVRAM, you must connect a workstation to the control module serial port (labeled DIAG PORT). After connecting the management workstation, launch a communications program that supports terminal emulation. Make sure that the terminal emulation settings specify 9600bps,
8 data bits, 1 stop bit, and no parity or flow control.
The default settings for the serial port profile allow anyone connecting to the diagnostics port to access the system as the administrative ( admin ) user, without logging in or being authenticated. When you connect to an unconfigured Stinger unit
5-6 Stinger® MS+ Getting Started Guide
Configuring the Control Module and System Timing
Restricting administrative access to which power has been applied, you are presented with the prompt for the admin user: admin>
interface by using Telnet from an IP host. Or, you can log in by using an SNMP management station, such as NavisAccess™, from an IP host. These types of connections require that you authenticate a User profile and supply a password to acquire administrative permissions. During basic configuration, Lucent Technologies recommends that you also configure the serial port to require username and password authentication.
For details about User profiles, see the Stinger Administration Guide .
Restricting administrative access
Each Stinger unit is shipped from the factory with its security features set to defaults that allow you to easily access the unit so you can configure it without any restrictions. Before you bring the unit online, you must change the default security settings to protect the configured unit from unauthorized access.
Changing defaults for serial-port logins
The factory default setting for the control module serial interface specifies that any connection to that interface will use the admin User profile. To help protect the system from unauthorized administrative access on the serial interface, change the following default setting:
[in SERIAL/{ shelf-1 first-control-module 2 }] user-profile = admin
Parameter
User-Profile
Setting
Name of the User profile to be used for logins on the control module serial port. User profiles set permissions and other parameters for logins to the Stinger command-line interface. If no name is specified, the system prompts for both the name and password of a User profile, as it does for
Telnet logins.
A Stinger unit automatically creates a Serial profile for the control module. To list the
Serial profiles, use the Dir command as follows: admin> dir serial
12 03/06/2003 02:57:48 { shelf-1 first-control-module 1 }
There is only one control module slot in Stinger MS+ units. The designation, first-control-module , refers to the slot labeled CTRL on the Stinger MS+ chassis.
This slot is referred to as slot 8 or first-control-module in the TAOS interface to maintain the uniformity of the TAOS interface across the Stinger product line.
To make serial logins more secure, modify the Serial profile of the control module to specify a null User profile name, as shown in the following example. Anyone trying
Stinger® MS+ Getting Started Guide 5-7
Configuring the Control Module and System Timing
Restricting administrative access to establish a connection through the serial port is then required to provide a username and password.
admin> read serial {1 8 2}
SERIAL/{ shelf-1 first-control-module 2 } read admin> set user-profile = admin> write
SERIAL/{ shelf-1 first-control-module 2 } written
Changing the default admin password
Because the admin User profile controls permissions that enable most levels of activity, access to that login must be carefully restricted. To protect the admin login, change its well-known default password the first time you log into the unit.
Following is the password parameter, shown with its factory default setting:
[in USER/admin] password = "Ascend"
Parameter
Password
Setting
Text string of up to 20 characters, which must be entered by a user to log in with permissions authorized by the admin profile. The value is case sensitive.
You can specify any password up to 20 characters. All future logins governed by the admin User profile must provide the new password.
For example, the following commands change the admin password to x1!35DPG
: admin> read user admin
USER/admin read admin> set password = x1!35DPG
admin> write
USER/admin written
When an administrator Telnets into the Stinger unit, the system prompts for the name and password of a User profile and authenticates the information before allowing the Telnet session. For example:
% telnet 1.1.1.1
Trying 1.1.1.1...
Connected to 1.1.1.1
Escape character is ‘^]’.
User: admin
Password: x1!35DPG
5-8 Stinger® MS+ Getting Started Guide
Configuring the Control Module and System Timing
Providing a basic system IP configuration
Setting a Telnet password
A Telnet password is a global, system-wide password required for Telnet logins to the unit. The Telnet password is requested before the system accepts the connection and prompts for the username. Following are the default parameters associated with
Telnet logins to a Stinger unit:
[in IP-GLOBAL] telnet-password = "" user-profile = ""
Parameter
Telnet-Password
User-Profile
Setting
Text string of up to 20 characters, required from all users requesting a Telnet session. A user is allowed three attempts, with 60 seconds per attempt, to enter the correct password. A third unsuccessful attempt terminates the login process. The value is case sensitive.
Sets the name of a default User profile for authenticating all
Telnet logins. If no name is specified, the system prompts the user to enter the name of a User profile.
For example, the following commands set the Telnet password to dpg01!
: admin> read ip-global
IP-GLOBAL read admin> set telnet-password = dpg01! admin> write
IP-GLOBAL written
When a Telnet password has been specified, the system requires a two-tier password authentication for Telnet logins, first the Telnet password, then the username and its associated password. For example:
% telnet 1.1.1.1
<stinger01> Enter Password: dpg01!
Trying 1.1.1.1...
Connected to 1.1.1.1
Escape character is ‘^]’.
User: admin
Password: **********
If the user enters an incorrect Telnet password, the system prompts again, allowing up to three attempts before timing out. If the user specifies the correct password, the connection is established and the user is prompted to enter the name and password of a valid User profile.
Providing a basic system IP configuration
To enable Telnet and SNMP access to the unit, and to allow connectivity between the unit and local IP hosts, you must assign IP addresses to the Stinger Ethernet ports and configure basic IP routing. A basic configuration for remote inband management can be saved in a special file called default.cfg
. If the basic configuration is saved in this way, the system can restart with the configured remote management capability,
Stinger® MS+ Getting Started Guide 5-9
Configuring the Control Module and System Timing
Providing a basic system IP configuration even after nonvolatile memory has been cleared with the NVRAM command. For more information about retaining a configuration after clearing NVRAM, see the
Stinger Administration Guide .
Note A Stinger unit does not require IP routing to operate as a DSLAM. IP routing is not used by the DSLAM activities. The system does not provide IP routing for DSLAM user data.
IP address syntax
The Stinger unit uses dotted decimal notation (not hexadecimal) for IP addresses.
Netmask information is appended to the IP address after a forward slash (/).
Netmasks
If no netmask is specified, the unit uses a default mask based on the class of the IP
address that is supplied. Table 5-1 shows address classes and the number of network
bits in the default mask for each class.
Table 5-1. IP address classes and number of network bits
Class Address range Default network bits
Class A
Class B
Class C
0.0.0.0 through 127.255.255.255
8
128.0.0.0 through
191.255.255.255
16
192.0.0.0 through
223.255.255.255
24
For example, a class C address, such as 198.5.248.40, has 24 network bits, leaving 8 bits for the host portion of the address. If no subnet mask is specified for a class C
address, the Stinger unit uses the default mask of 24 bits, as shown in Figure 5-5.
Figure 5-5. Default netmask for class C IP address
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
Default 24 bits
By default, this address is displayed as 198.5.248.40/24.
Subnets
Subnets are permitted under the same syntax. A subnet address specifies a number of network bits that does not adhere to the Class A, B, or C network limits. For example, the following address specifies a 29-bit subnet: ip-address = 198.5.248.40/29
In this address, 29 bits of the address are used to specify the network. The 3 remaining bits are used to specify eight addresses on the subnet. With 3 bits used to specify hosts on a 29-bit subnet, eight different bit combinations are possible. Of those eight possible host addresses, two are reserved:
5-10 Stinger® MS+ Getting Started Guide
Configuring the Control Module and System Timing
Providing a basic system IP configuration
000 — Reserved for the network (base address)
001
010
100
110
101
011
111 — Reserved for the broadcast address of the subnet
Note Early implementations of TCP/IP did not allow zero subnets (subnets with the same base address as a class A, B, or C network). For example, the subnet
192.32.8.0/30 was illegal because it had the same base address as the class C network
192.32.8.0/24, while the subnet 192.32.8.4/30 was legal. Modern implementations of TCP/IP support zero subnets, and the Stinger implementation of Routing
Information Protocol (RIP) treats these subnets the same as any other network. Make sure that you treat zero subnets consistently throughout your network. Otherwise, you might encounter routing problems.
Table 5-2 shows subnet masks and prefix lengths for a class C network.
Table 5-2. Decimal subnet masks and prefix lengths
Subnet mask Number of host addresses Prefix length
255.255.255.0
254 hosts + 1 broadcast address, 1 network base address
255.255.255.128
126 hosts + 1 broadcast address, 1 network base address
/24
/25
255.255.255.192
62 hosts + 1 broadcast address, 1 network base address /26
255.255.255.224
30 hosts + 1 broadcast address, 1 network base address /27
255.255.255.240
14 hosts + 1 broadcast address, 1 network base address /28
255.255.255.248
6 hosts + 1 broadcast address, 1 network base address /29
255.255.255.252
2 hosts + 1 broadcast address, 1 network base address /30
255.255.255.254
Invalid mask (no hosts) /31
255.255.255.255
1 host—a host route /32
The broadcast address of any subnet has the host portion of the IP address set to all 1s
(ones). The network address (or base address) represents the network itself, because the host portion of the IP address is all 0s (zeros). For example, suppose that the
Stinger configuration assigns the following address to a remote router:
198.5.248.120/29
The Ethernet network attached to that router has the following address range:
198.5.248.120 — 198.5.248.127
A host route is a special-case IP address with a prefix length of /32. For example:
Stinger® MS+ Getting Started Guide 5-11
Configuring the Control Module and System Timing
Providing a basic system IP configuration
198.5.248.40/32
Host routes are routes to a single host, rather than to a network or subnet. This is determined by the fact that a 32-bit netmask does not allow for any host addresses on the network, other than the single address that is specified. It is, in effect, a one-address subnet.
Assigning the Ethernet IP addresses
A Stinger unit creates an IP interface for the Ethernet port of the control module. Use the Dir command to list the IP interfaces, as follows: admin> dir ip-interface
18 03/06/2003 16:36:32 { { any-shelf any-slot 0 } 0 }
29 03/06/2003 16:27:57 { { shelf-1 first-control-module 1 } 0 }
The IP interface profile identified as, first-control-module 1 , refers to the IP interface of the first (and only) physical Ethernet port on the control module in the
Stinger MS+ chassis. The IP-Interface profile with the zero index (the default any-shelf any-slot index) is reserved for the soft interface of the unit, which is
described in “Defining the soft IP interface” on page 5-12.
Note The designation, first-control-module , refers to the slot position of the control module in Stinger units that support redundant control modules. There is only one control module slot in Stinger MS+ units. This slot is referred to as slot 8 or first-control-module in the TAOS interface to maintain the uniformity of the
TAOS interface across the Stinger product line.
The following commands assign the address 1.1.1.56/24 to the ethernet interface on the control module: admin> read ip-interface { { shelf-1 8 1 } 0 }
IP-INTERFACE/{ { shelf-1 first-control-module 1 } 0 } read admin> set ip-address = 1.1.1.56/24 admin> write
IP-INTERFACE/{ { shelf-1 first-control-module 1 } 0 } written
After you assign IP addresses, you can verify that the Stinger unit is a valid IP host on its configured network by pinging other network hosts, as shown in the following example: admin> ping 1.1.1.56
PING 1.1.1.56: 56 Data bytes
64 bytes from 1.1.1.56: icmp_seq=0 ttl=255 time=0 ms
64 bytes from 1.1.1.56: icmp_seq=3 ttl=255 time=0 ms
^C
--- 1.1.1.56: Ping statistics ---
2 packets transmitted, 2 packets received, 0% packet loss round-trip min/avg/max = 0/0/0 ms
Defining the soft IP interface
A Stinger unit supports a soft IP interface that can be assigned its own IP address. the address of the soft IP interface becomes a second (proxy) address for Ethernet port on the primary or only control module in the unit. In Stinger models that support redundant control modules, this soft address can be reached through the Ethernet interface of whichever control module is the primary control module. Therefore,
5-12 Stinger® MS+ Getting Started Guide
Configuring the Control Module and System Timing
Providing a basic system IP configuration regardless of which control modules is functioning as the primary control module for the chassis, the unit can be accessed through the same soft interface address.
When power is applied to the system, the soft IP interface address is not initialized until a control module assumes the role of primary control for the Stinger unit. The
Ethernet interface of the primary control module can then respond to ARP requests for the soft IP interface address in addition to requests for its own IP address, which was previously configured. If the secondary control module becomes primary, the system reinitializes the soft IP interface address to the Ethernet interface of the new primary control module.
The soft IP interface is configured in the IP-Interface profile with the zero index.
The following commands set the soft interface IP address to 1.1.1.128/24: admin> read ip-interface {{ 0 0 0 }}
IP-INTERFACE/{ { any-shelf any-slot 0 } 0 } read admin> set ip-addr = 1.1.1.128/24 admin> write
IP-INTERFACE/{ { any-shelf any-slot 0 } 0 } written
Configuring a default route
A default route is a static route that specifies a destination for addresses that are not on the local network and to which a known route does not exist. The default route is generally the IP address of an external router that has more route information about how specific destinations can be reached. When the default route is configured, the
Stinger unit routes all IP packets with unknown destinations to the specified external router. If no default route is defined, the unit drops IP packets for which it has no route.
Figure 5-6 shows the Stinger Ethernet interface on a subnet, connected to the same
Ethernet segment as a local backbone router. In this network, the Stinger unit can use the local router as its default route.
Figure 5-6. Local backbone router to be used as default route
1.1.1.1/24
Control module’s
Ethernet port address
1.1.2.3/24
Local
1.1.1.3/24
If a local router is the unit’s default route, or gateway, the Stinger unit can pass all IP packets with an unrecognized address to that router, so its own routing table can remain small. The external router maintains larger routing tables and assumes the responsibility and overhead of routing most packets.
For example, the following commands define a default route to the LAN router in
Stinger® MS+ Getting Started Guide 5-13
Configuring the Control Module and System Timing
Configuring system clocking admin> new ip-route default
IP-ROUTE/default read admin> set gateway-address = 1.1.1.3 admin> set active-route = yes admin> write
IP-ROUTE/default written
The system can support multiple default routes. The profile name does not have to be default . The only requirements are that the destination address must be zero, and
Gateway-Address must specify a valid, accessible router.
For information about other settings in the IP-Route profile, see the Stinger Reference
Guide .
Verifying a LAN connection for administrators
To enable administrators to log into the Stinger unit’s interface from IP hosts, you must also make sure your local network can route to the unit. Your network router must have network connectivity through intermediate routers so that the administrative host can access the Stinger unit via its IP address. You can test this connectivity by pinging the unit from the local host. For example, the following command entered on a local host tests connectivity to the Stinger soft interface, identified previously:
% ping 1.1.1.128
PING 1.1.1.128 (1.1.1.128): 56 Data bytes
64 bytes from 1.1.1.128: icmp_seq=0 ttl=255 time=0 ms
64 bytes from 1.1.1.128: icmp_seq=7 ttl=255 time=0 ms
^C
--- 1.1.1.128 Ping statistics ---
8 packets transmitted, 8 packets received, 0% packet loss round-trip min/avg/max = 0/0/0 ms
Configuring system clocking
The Stinger unit requires a clock source for its timing subsystem. By default, it uses a built-in 8kHz clock on the control module as its timing source. You can configure the system to take its clock source from a trunk port or from an external building interoffice timing source (BITS) clock connected to the Stinger MS+ unit.
Using the default (controller) clock source
The Stinger unit has an internal 8kHz clock on its control module. By default, the unit uses the clock on the control module as the source for its timing subsystem. To configure the unit to obtain its clock signal from another source, set the following parameter (shown with its default setting):
5-14 Stinger® MS+ Getting Started Guide
Configuring the Control Module and System Timing
Configuring system clocking
[in SYSTEM] system-8k-clock = controller
Parameter
System-8K-Clock
Setting
Source for the master system clock.
With the default controller setting, the Stinger MS+ unit uses the built-in 8kHz clock on the control module.
If set to lim-or-trunk-module , the unit obtains its clock signal from a trunk port that has been configured as an eligible clock source, using the ports in order of their priority. If no eligible trunk ports are available, it uses the control module clock.
If set to bits , the unit sources its clock from the building interoffice timing source (BITS) T1 framer in its alarm unit.
If set to ami-8k , a model A-J control module sources the
400Hz ISDN reference clock used in Japan, from the BITS input across the backplane for use by Annex C LIMs. (The model A-J control module is available only for the Stinger
LS.)
Using the BITS clock source
The following commands cause the system to first attempt to use a BITS clock as its clock source, and to use the built-in clock only if it does not find a valid BITS signal: admin> read system
SYSTEM read admin> set system-8k-clock = bits admin> write
SYSTEM written
Loss of BITS signal indications and fall-back
If the system-8K-clock parameter in the system profile is set to bits and the system detects a loss of signal, it displays the following message:
LOG alert, Shelf 1, Controller-1, Time: 17:02:01--
BITS clock source has been lost - 8kHz clock is free running
If no other clock source is eligible, the system then displays the following message:
LOG notice, Shelf 1, Controller-1, Time: 17:02:01
Master clock source changed to local oscillator
When the Stinger unit recovers the BITS signal, it displays the following messages:
LOG alert, Shelf 1, Controller-1, Time: 17:02:03--
BITS clock source has been recovered - 8kHz clock is locked
LOG notice, Shelf 1, Controller-1, Time: 17:02:03--
Master clock source changed to T1 framer
Stinger® MS+ Getting Started Guide 5-15
Configuring the Control Module and System Timing
Configuring system clocking
If the Stinger unit detects a T1 signal in the BITS input, it prioritizes the clock source list as follows:
■
■
If the system-8K-clock parameter of the system profile is set to bits , its priority is set to the highest (1) and the T1 framer is selected regardless of other available clock sources and priorities.
If the system-8K-clock parameter of the system profile is set to a value other than bits , its priority is set as the lowest (3) and the T1 framer is selected as a clock source only if no other slot clock sources are available.
Changing the BITS clock source
The following examples show how to change the system-8K-clock parameter setting from bits to lim-or-trunk-module and use the slot-clock-source command to view the changes in clock source priority: admin> set system-8k-clock = bits admin> write
LOG notice, Shelf 1, Controller-1, Time: 17:55:34--
Master clock source changed to T1 framer
SYSTEM written admin> slot-clock-source
Master line: T1 framer
Source List:
Source: line 1 Available* priority: 2
Source: line 2 Available* priority: 1
Source: T1 framer Available* priority: 1 admin> set system-8k-clock = lim-or-trunk-module admin> write
LOG notice, Shelf 1, Controller-1, Time: 17:56:05--
Master clock source changed to slot-1/8 line 2
SYSTEM written admin> slot-clock-source
Master line: 2 source List:
Source: line 1 Available* priority: 2
Source: line 2 Available* priority: 1
Source: T1 framer Available* priority: 3
Using a LIM or trunk module clock source
The following commands cause the system to first attempt to use a trunk port as its clock source, and to use the built-in clock only if it finds no ports that are eligible clock sources: admin> read system
SYSTEM read admin> set system-8k-clock = lim-or-trunk-module
5-16 Stinger® MS+ Getting Started Guide
Configuring the Control Module and System Timing
Configuring system clocking admin> write
SYSTEM written
Configuring trunk ports as eligible clock sources
The DS3-ATM, OC3-ATM, and E3-ATM profiles support Clock-Source and
Clock-Priority parameters for specifying whether the port can be used to source the
ATM network clock and feed it to the primary control module as the master clock for the unit. Each of the two trunk ports can be configured as eligible or ineligible for this use, and can be assigned a high, middle, or low priority for being elected as the clock source. Following are the relevant parameters, shown with default settings:
[in DS3-ATM/{ any-shelf any-slot 0 }:line-config] clock-source = not-eligible clock-priority = middle-priority
[in OC3-ATM/{ any-shelf any-slot 0 }:line-config] clock-source = not-eligible clock-priority = middle-priority
[in E3-ATM/{ any-shelf any-slot 0 }:line-config] clock-source = not-eligible clock-priority = middle-priority
Parameter
Clock-Source
Clock-Priority
Setting
Enable/disable obtaining the system clock signal from the port. By default, ports are not eligible clock sources.
Priority of the interface as the system’s clock source (high, middle, or low priority). Once the Stinger unit chooses a clock source, it uses that source until the interface becomes unavailable or a higher-priority source becomes available.
If more than one line is eligible to be the clock source, the system chooses the one with the highest priority, as specified by the Clock-Priority setting. If multiple sources of equal priority are present, the system selects the first valid clock source. (A clock source is valid if the Clock-Source parameter is set to eligible and the DS3, OC3, or E3 interface is synchronized.)
Once it has selected a clock source, the system uses that source until the source becomes unavailable or a higher-priority source becomes available. If no eligible external sources exist, the system uses an internal clock generated by the primary control module.
Typical trunk port clock source configurations
The following sample commands configure both ports of a DS3-ATM module as eligible clock sources, with the first port assigned a higher priority for this use: admin> read ds3-atm { 1 trunk-module-1 1 }
DS3-ATM/{ shelf-1 trunk-module-1 1 } read admin> set line-config clock-source = eligible admin> set line-config clock-priority = high admin> write
DS3-ATM/{ shelf-1 trunk-module-1 1 } written
Stinger® MS+ Getting Started Guide 5-17
Configuring the Control Module and System Timing
Configuring system clocking admin> read ds3-atm { 1 trunk-module-1 2 }
DS3-ATM/{ shelf-1 trunk-module-1 2 } read admin> set line-config clock-source = eligible admin> set line-config clock-priority = low admin> write
DS3-ATM/{ shelf-1 trunk-module-1 2 } written
Additional information about configuring OC3-ATM, DS3-ATM, and E3-ATM trunk modules can be found in the Stinger OC3-ATM Trunk Module Guide , the Stinger DS3-ATM
Trunk Module Guide , and the Stinger E3-ATM Trunk Module Guide .
5-18 Stinger® MS+ Getting Started Guide
Installing and Removing
Modules
6
Installation and replacement considerations
The Stinger unit design enables you to install, remove, and replace most modules without shutting the unit off. However, you can turn off power to the unit as a precaution, if the unit is not currently providing service.
Warning Do not attempt to replace the power filter on a Stinger FS or Stinger FS+ unit. Doing so, you risk contact with live, electrically charged components of the unit.
Warning Before installing your Stinger unit, be sure to read the safety instructions in the Edge Access and Broadband Access Safety and Compliance Guide . For information
specific to your unit, see Appendix C, “Safety-Related Electrical, Physical, and
Environmental Information,” in this guide.
Warning If power to the unit is not turned off, an electrical energy hazard is present within the card cage. Remove all metallic objects from hands and wrist to prevent bridging of live contact points.
Caution Wear an antistatic wrist strap before handling any of the unit components.
!
Stinger® MS+ Getting Started Guide 6-1
Installing and Removing Modules
Replacing and installing control modules
2
Replacing and installing control modules
!
Caution The control module should not be replaced while the Stinger MS+ unit is in operation. Hot-swap replacement of an active control module causes a Stinger unit to crash.
Removing a control module
To remove a control module:
1
front of the Stinger unit. (See Figure 1-5 on page 1-7.)
2 If the unit does not contain a redundant control module, or if both the primary control module and the secondary control module are being replaced simultaneously, notify all users that the unit is being shut down.
3 Turn off power to the unit.
4 Using a number 2 Phillips screwdriver, loosen the thumbscrews located on each
side of the control module, as shown in Figure 6-1. Other screwdrivers might
damage the screw heads.
5 Slide the ejector lock on the left side of the control module to the right to access the card ejector. This puts the module into a reset state.
6-2 Stinger® MS+ Getting Started Guide
Figure 6-1. Removing a control module
1
1
Installing and Removing Modules
Replacing and installing control modules
3
4
1
2
MAJO
R MINOR
BITS
3
4
1
2
MAJO
R MINOR
BITS
1
1
2
3
4
MAJO
R
MINOR
BITS
3
4
1
2
MAJO R
MINOR
BITS
6 Lift the card ejectors on both sided of the card simultaneously to remove the module from the unit.
7 Carefully slide the control module out of the chassis, and place it into an antistatic container.
Installing a control module
To install a control module:
1
front of the unit. (See Figure 1-5 on page 1-7.)
2 Align the replacement control module with the card guide and carefully slide the
module into the unit, as shown in Figure 6-2.
3 Depress the card ejectors simultaneously to seat the module into the midplane.
Stinger® MS+ Getting Started Guide 6-3
Installing and Removing Modules
Replacing and installing control modules
Figure 6-2. Installing a control module
1
2
3
4
MAJO
R MINO
R
BITS
1
1
2
3
4
MAJO
R MINO
R
BITS
6-4
1
1
1
2
3
4
MAJO
R
MINO R
BITS
3
4
1
2
MAJO
R MINO
R
BITS
4 Slide the card ejector lock up.
5 Using a number 2 Phillips screwdriver, tighten the two thumbscrews.
6 If necessary, restore power to the unit.
7 Verify the following behavior of the status lights on the control module to verify its operational status:
– The MAJOR alarm light on the newly installed control module turns ON
(amber) when you turn on power to the unit, and then blinks while the
TAOS software image is downloading. After several minutes of operation, the
MAJOR alarm light turns OFF.
– On a single or primary control module , the MASTER light at the bottom is ON
(solid green) to indicate that the module is active.
– On a redundant (secondary) control module , the MASTER light at the bottom is
OFF to indicate that the module is in a standby mode.
Stinger® MS+ Getting Started Guide
Installing and Removing Modules
Slot numbering and module placement
Slot numbering and module placement
LIM are installed in the slots numbered from 1 to 4 in the front of the Stinger MS+ chassis. These slots are also logically referred to by the TAOS software as slots 1 through 4, corresponding with their physical location in the chassis.
The top slot in the front of the unit is labeled “CTRL”. This slot is reserved for the control module. To maintain the uniformity across the Stinger product line, this slot is logically referred to by the TAOS software as slot 8.
The top slot in the rear of the unit is labeled “TM”. This slot is reserved for a trunk or
TRAM module. To maintain the uniformity across the Stinger product line, this slot is logically referred to by the TAOS software as slot 17.
Installing and replacing LIMs
Physical installation and replacement of a LIM are similar procedures to the installation and replacement of a control module. Refer to the illustration in
Figure 6-2 on page 6-4, if necessary.
Installing a LIM
To install a LIM:
1
front of the unit. (See Figure 1-5 on page 1-7.)
2 Remove the blank slot cover on the desired slot on the front of the unit. (See
“Slot numbering and module placement” on page 6-5.)
3 Align the LIM with the card guides and carefully slide the module into the unit.
Note Keep the connector on the LIM being inserted away from components on adjacent LIMs. Do not force the card. Once the card has engaged its bus connector, press firmly to be sure it is fully seated.
4 Depress the ejectors simultaneously.
5 Slide the card ejector lock up.
6 Using a number 2 Phillips screwdriver, secure the LIM by tightening the thumbscrews.
7 If necessary, if all other installation tasks are complete, including the installation of an associated LPM, turn on power to the Stinger unit.
8 Wait several minutes and then verify the behavior of the status lights on the LIM to verify its operational status.
For status light information, see the module guide for the LIM you are installing.
Replacing a LIM
!
Caution Lucent Technologies recommends setting the administrative status of the
LIM to Down (through the command-line interface) before replacing the module.
When a LIM is removed, all its ports and circuits are terminated, and data loss might occur. For instructions on changing a LIM’s state to Down and then back to Up, see the Stinger Administration Guide .
Stinger® MS+ Getting Started Guide 6-5
Installing and Removing Modules
Installing and replacing LPMs
Refer to the illustration in Figure 6-1 on page 6-3, if necessary.
To replace a LIM:
1
front of the unit. (See Figure 1-5 on page 1-7.)
2 Using a number 2 Phillips screwdriver, loosen the top and bottom thumbscrews attaching the module to the unit.
3 Slide the ejector lock located at the top of the LIM down to disconnect the module from the network.
4 Lift the top and bottom card ejectors simultaneously to remove the module from the unit. Lift both ejectors simultaneously to avoid damage to the module.
5 Carefully slide the LIM out of the unit and place it into an antistatic container.
6 Align the LIM with the card guides and carefully slide the module into the unit.
Note Keep the connector on the LIM being inserted away from components on adjacent LIMs. Do not force the card. Once the card has engaged its bus connector, press firmly to be sure it is fully seated.
7 Depress the ejectors simultaneously.
8 Slide the card ejector lock up.
9 Using a number 2 Phillips screwdriver, secure the module into the unit by tightening the thumbscrews on the LIM.
10 Wait several minutes and then verify the behavior of the status lights on the LIM to verify its operational status.
For status light information, see the module guide for the LIM you are installing.
Installing and replacing LPMs
Installation and replacement of line protection modules (LPMs) is similar to the procedure for line interface modules (LIMs), except that LPMs are installed in the rear of the chassis and their top ejector levers are not protected by ejector locks.
Openings for unused LPM slots are protected by blank covers. Unless LIMs with integrated protection are used, a companion LPM must be installed in the back of the unit for each LIM.
Installing an LPM
To install an LPM:
1
back of the unit. (See Figure 1-7 on page 1-10.)
2 Remove the blank filler module covering the LPM’s slot.
3 Align the LPM with the card guides and gently slide the LPM into the unit.
4 Using a number 2 Phillips screwdriver, secure the module into the unit by tightening the thumbscrews on the LPM.
5
Connect the cables as described in “Connecting to the LPMs” on page 2-3.
6-6 Stinger® MS+ Getting Started Guide
Installing and Removing Modules
Installing and replacing LPMs
Replacing an LPM
!
Caution Any circuits running through the LPM are interrupted when it is removed, which can result in data loss. Lucent Technologies recommends setting the associated
LIM’s administrative status to Down before removing the LPM from the unit. For instructions on changing a LIM’s state to Down and then back to Up, see the Stinger
Administration Guide .
To replace an LPM:
1
front or back of the unit. (See Figure 1-5 on page 1-7 and Figure 1-7 on page 1-10.)
2 Carefully unhook the cable ties securing the connectors and cables to the card and remove all connectors and cables.
3 Using a number 2 Phillips screwdriver, loosen the left and right thumbscrews
attaching the module to the unit, as shown in Figure 6-3.
Figure 6-3. Removing an LPM
GREEN-A
CTIVE
RED-F
AILED
2
1
4
3
CAUT
ION
ARTS
MOVING P
GREEN-A
CTIVE
RED-F
AILED
2
1
4
3
CAUT
ION
ARTS
MOVING P
GREEN-A
CTIVE
RED-F
AILED
2
1
4
CAUT
ION
ARTS
MOVING P
3
4 Lift the left and right card ejectors simultaneously to disengage the module from the midplane connectors. Lift both ejectors simultaneously to avoid damage to the module.
5 Carefully slide the LPM out of the unit and place it into an antistatic container.
6 Align the new or replacement LPM with the card guides and carefully slide the module into the unit. Press firmly to be sure it has engaged the midplane connectors.
7 Depress the ejectors simultaneously.
Stinger® MS+ Getting Started Guide 6-7
Installing and Removing Modules
Installing and replacing PCMCIA cards
8 Using a number 2 Phillips screwdriver, secure the module into the unit by tightening the thumbscrews on the LPM.
9
Reconnect the cables, as described in “Connecting to the LPMs” on page 2-3.
Installing and replacing PCMCIA cards
To remove the PCMCIA cards from the control module, push the square, flat black buttons at the bottom of each PCMCIA card to eject the cards. After the cards are removed, make sure they remain guarded against static discharge.
To install the PCMCIA cards in the control module, line the card edge up with the guides, and push the card in until the black ejector button pops back up.
Replacing the cooling module
The cooling module contains fans for cooling the unit and the electronics that control and monitor their operation. The cooling module is installed in the rear of the chassis. It is not necessary to remove power from the unit while replacing the cooling module.
!
Caution To avoid overheating the unit, you must minimize the time that the cooling module is removed from the chassis. Have the new module unpacked and ready for installation before removing the old cooling module.
To replace an LPM:
1
front or back of the unit. (See Figure 1-5 on page 1-7 and Figure 1-7 on page 1-10.)
2 Using a number 2 Phillips screwdriver, fully loosen the cooling module locking
Warning Keep your fingers away from the fan blades in the cooling module. Fan blades may be moving with the cooling module is removed from the enclosure.
3 Grasp the extraction handle of the cooling module and pull the cooling module about 0.5in. (12.7mm) out of the enclosure. Wait until the fans stop moving (at least 20 to 30 seconds).
4 When the fan blades have stopped moving pull the cooling module straight out
of the chassis, as shown in Figure 6-4.
6-8 Stinger® MS+ Getting Started Guide
Figure 6-4. Replacing the cooling module
Installing and Removing Modules
Replacing a power filter
GREEN-A
CTIVE
RED-F
AILED
2
1
4
3
N
CAUTIO
MOVIN
G PAR
TS
Locking screw
Extraction handle
5 Align the replacement module to slide straight into the opening in the back of the chassis.
6 Carefully slide the replacement cooling module into the chassis and press firmly to engage the power connector in the chassis.
7 Fully tighten the locking screw on the replacement cooling module.
Replacing a power filter
The power filters are located in the front of the chassis. Before replacing a power filter, the Stinger unit must be removed from service and there must not be any supply voltage on the cables connected to the unit.
To replace a power filter:
1 Verify that power has been removed from the cables that connect to the power filter.
2 Remove the protective cover and power cables from the power filter, as
illustrated in Figure 3-1 on page 3-2.
3 Using a number 2 Phillips screwdriver, fully loosen the power filter locking screw,
4 Grasp the extraction handle of the power filter and pull it straight out of the chassis.
Stinger® MS+ Getting Started Guide 6-9
Installing and Removing Modules
Replacing the alarm module
Figure 6-5. Replacing a power filter
MAJO
R
MINOR
BITS
Guide tabs
RTN
-48VDC
Guide slots
Locking screw Extraction handle
5 Align the guide tabs on either side of the replacement power filter with the guide slots in the chassis.
6 Carefully slide the replacement power filter into the chassis and press firmly to engage the power connector.
7 Fully tighten the locking screw on the replacement power filter.
Replacing the alarm module
The alarm module is located in the front of the chassis.
To replace the alarm module:
1 Remove any connections to the alarm and BITS terminals. Note the way in which any wires are connected, so they can be returned to their connections after replacement of the module.
2 Using a number 2 Phillips screwdriver, fully loosen the alarm module locking
3 Grasp the extraction handle of the alarm module and pull it straight out of the chassis.
6-10 Stinger® MS+ Getting Started Guide
RTN
-48VDC
Installing and Removing Modules
Replacing the alarm module
Figure 6-6. Replacing an alarm module
RTN
-48VDC
Guide slots
Circuit board edges
Locking screw
MAJO
R
MINOR
BITS
Extraction handle
4 Align the edges of the replacement alarm module circuit board with the guide slots in the chassis.
5 Carefully slide the replacement alarm module into the chassis and press firmly to engage the connector.
6 Fully tighten the locking screw on the replacement alarm module.
Stinger® MS+ Getting Started Guide 6-11
Stinger Intended Use
A
The Stinger unit is a DSL ATM switch that provides DSL connections for individual users. Users connect to the unit over DSL lines supported by line interface modules
(LIMs) that are installed in the Stinger unit. Every Stinger unit contains a special control module that controls the operation of the unit. Two control modules can be installed in a redundant arrangement, with one active and primary, and the other a spare. The physical interfaces on the unit provide DSL or ATM network connections to digital lines, and a serial or Ethernet LAN connection for configuration and administration. Units equipped with revision 2, or later, control modules also provide interfaces for monitoring the alarm status of other devices, and an optional internal modem.
User line interfaces
Depending on the LIMs that are installed, users can connect to the Stinger unit over
DSL lines supporting several DSL protocols. LIMs are available to support the following DSL connections:
■
■
■
ADSL Annex A, B, or C
ADSL G.lite
SHDSL
See the module guide of a specific LIM for an explanation of installation and configuration options .
User connection to each LIM is provided through an associated line protection module (LPM).
Network interfaces
The Stinger unit extracts data from the digital subscriber line and switches it to remote ATM switches depending on the configuration of virtual circuit and path information. Stinger modules are available that support ATM connections to ATM network switches over the following types of digital lines:
Stinger® MS+ Getting Started Guide A-1
Stinger Intended Use
Control module interfaces
■
■
■
■
■
T1 (individual lines or aggregated bandwidth)
E1 (individual lines or aggregated bandwidth)
DS3
E3
OC3
For an explanation of installation and configuration options, see the guide for a specific module.
Control module interfaces
The control module is equipped with the following interfaces for configuration and
administration. For an explanation of basic configuration options, see Chapter 5,
“Configuring the Control Module and System Timing.”
■ A DB-9 female connector for an RS-232 serial connection, with the following default settings:
– 9600bps
– Direct connection
– 8 data bits
– No parity
■
■
■
■
■
■
– 1 stop bit
– No flow control
A DB-9 female connector for alarm monitoring connections (revision 2 control modules).
An RJ-45 connector for a 10/100BaseT Ethernet connection.
An RJ-11 connector for the optional internal modem.
A PCMCIA interface, designed to accept PCMCIA flash-memory cards. Other
PCMCIA devices are not supported.
An RJ-45 connector for copper gigabit Ethernet connections, if equipped with an appropriate IP2000 control module.
A duplex LC connector for optical gigabit Ethernet connections, if equipped with an appropriate IP2000 control module.
A-2 Stinger® MS+ Getting Started Guide
Cables and Connectors
B
Diagnostic port and cable pinouts
The diagnostic port uses a standard DB-9 female connector that conforms to the EIA
RS-232 standard for serial interfaces. Table B-1 applies to all [Product] models that
use the RS-232 pinouts.
Note .
Table B-1. Diagnostic port and cable pinouts
DB-9 pin number
RS-232 signal name
Function I/O
5
6
7
3
4
1
2
8
9 a a.
DCD
RD
SD
DTR
GND
DSR
RTS
CTS
RI
Data Carrier Detect
Serial Receive Data
Serial Transmit Data
Data Terminal Ready
Signal Ground
Data Set Ready
Request to Send
Clear to Send
Ring Indicator
Pin 9 is not active. (Ring Indication signal not supplied.)
I
I
O
O
O
I
O
O
Stinger® MS+ Getting Started Guide B-1
Cables and Connectors
Alarm input port pinouts
Alarm input port pinouts
The alarm input port, found on revision 2 control modules, consists of a DB-15 female connector. This connector provides seven pairs of pins that can be connected to the alarm relays of up to seven external devices. Operation or nonoperation of these alarm relays is sensed by the TAOS software, based on continuity or lack of continuity between the pair of pins to which it is connected.
The sensing connections apply 3.3Vdc at less than 10mA through the closed contacts of the remote relay. The cable associated with this connector must consist of 24-gauge to 28-gauge conductors.
Table B-2 provides the pinouts for the DB-15 alarm input port.
Table B-2. Alarm input pinouts
Ground Connection Alarm Relay
Number
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Sensing
Connection
Pin 1
Pin 3
Pin 5
Pin 7
Pin 10
Pin 12
Pin 14
Pin 2
Pin 4
Pin 6
Pin 8
Pin 11
Pin 13
Pin 15
Ethernet interface specifications
The base Stinger unit has an Ethernet interface that supports the physical specifications of IEEE 802.3 and IEEE 802.14 with Ethernet 2 (Ethernet/DIX) framing. The unit provides a single Ethernet interface that automatically senses the
Ethernet type to which it is connected. It supports the following types of Ethernet interfaces:
■
■
10BaseT (unshielded twisted pair): Twisted-pair Ethernet and IEEE 802.3
(10BaseT) with an RJ-45 connector, labeled LAN UTP
100BaseT: 100Mbps baseband modulation on twisted pair
The Ethernet address used to identify the Ethernet interface resides in the [Product] unit’s motherboard.
To install the Ethernet interface, you must have the cables described in either of the following two sections.
B-2 Stinger® MS+ Getting Started Guide
Cables and Connectors
LPM cable specifications
10BaseT cables
To install a 10BaseT interface, you need a twisted-pair Ethernet cable and a dual twisted-pair cable terminated with RJ-45 modular jacks.
Use an EIA/TIA 568 or IEEE 802.3 10BaseT cable.
100BaseT cables
To install a 100BaseT interface, you need a twisted-pair Ethernet cable and a dual twisted-pair cable terminated with RJ-45 modular jacks.
Use one of the following cables: 100BaseT2, 100BaseT4 (not very popular),
100BaseTX, or 100BaseFX.
LPM cable specifications
Depending on the type of DSL service being provided by the associated LIM, LPMs support two-wire or four-wire connections to the DSL end user.
The LPMs use USOC RJ-21X 50-pin telephone company connectors, as shown in
Figure B-1. USOC RJ-21X 50-pin connector
50 25
26 1
LPM two-wire cable specifications
Depending on the number of ports provided by the associated LIM, an LPM can have one, two, or three connectors:
■
Table B-3 shows the cable pinouts for the single 50-pin connector for two-wire
connections on an LPM that supports LIMs with 24 ports
■
■
Table B-4 shows the cable pinouts for the upper 50-pin connector for two-wire
connections on an LPM that supports LIMs with more than 48 ports.
Table B-5 shows the cable pinouts for the middle 50-pin connector for two-wire
connections on an LPM that supports LIMs with 72 ports.
Stinger® MS+ Getting Started Guide B-3
Cables and Connectors
LPM cable specifications
B-4
Table B-3. Single or lower connector pin assignments for two-wire connections
Pin
1
21
22
23
18
19
20
24
25
15
16
17
12
13
14
9
10
11
6
7
8
4
5
2
3
Signal
12R
13R
14R
15R
16R
17R
18R
19R
20R
21R
22R
23R
24R
Not used
6R
7R
8R
9R
10R
11R
1R
(line 1 ring)
2R
3R
4R
5R
Color code
Blue/white
Pin
26
Orange/white 27
Green/white
Slate/white
Blue/red
Orange/red
Green/red
Brown/red
Slate/red
Blue/black
Green/black
Brown/black
Slate/black
Blue/yellow
28
Brown/white 29
30
31
32
33
34
35
36
Orange/black 37
38
39
40
41
Orange/yellow 42
Green/yellow 43
Brown/yellow 44
Slate/yellow 45
Blue/violet 46
Orange/violet 47
Green/violet 48
Brown/violet 49
N/A 50
Color code
White/blue
White/orange
White/green
White/brown
White/slate
Red/blue
Red/orange
Red/green
Red/brown
Red/slate
Black/blue
Black/orange
Black/green
Black/brown
Black/slate
Yellow/blue
Yellow/orange
Yellow/green
Yellow/brown
Yellow/slate
Violet/blue
Violet/orange
Violet/green
Violet/brown
N/A
Signal
12T
13T
14T
15T
16T
17T
18T
19T
20T
21T
22T
23T
24T
Not used
6T
7T
8T
9T
10T
11T
1T
(line 1 tip)
2T
3T
4T
5T
Stinger® MS+ Getting Started Guide
Cables and Connectors
LPM cable specifications
Modules supporting more than 24 lines use the connections indicated in Table B-4
for the upper 50-pin connector.
Table B-4. Upper connector pin assignments for two-wire connections
Pin
1
14
15
16
17
10
11
12
13
8
9
6
7
4
5
2
3
22
23
24
25
18
19
20
21
Signal
36R
37R
38R
39R
32R
33R
34R
35R
28R
29R
30R
31R
25R
(channel 1 ring)
26R
27R
33R
45R
46R
47R
40R
41R
42R
43R
48R
Not used
Color code
Blue/white
Blue/red
Orange/red
Green/red
Brown/red
Slate/red
Blue/black
Orange/black 37
Green/black 38
Brown/black
Slate/black
Blue/yellow 41
Orange/yellow 42
Green/yellow 43
Brown/yellow 44
Slate/yellow
Blue/violet
Pin
26
Orange/white 27
Green/white 28
Brown/white 29
Slate/white 30
31
32
33
34
35
36
39
40
45
46
Orange/violet 47
Green/violet 48
Brown/violet 49
N/A 50
Signal
25T
(channel 1 tip)
38T
39T
40T
41T
34T
35T
36T
37T
30T
31T
32T
33T
26T
27T
28T
29T
42T
43T
33T
45T
46T
47T
48T
Not used
Color code
White/blue
White/orange
White/green
White/brown
White/slate
Red/blue
Red/orange
Red/green
Red/brown
Red/slate
Black/blue
Black/orange
Black/green
Black/brown
Black/slate
Yellow/blue
Yellow/orange
Yellow/green
Yellow/brown
Yellow/slate
Violet/blue
Violet/orange
Violet/green
Violet/brown
N/A
Stinger® MS+ Getting Started Guide B-5
Cables and Connectors
LPM cable specifications
Pin
1
21
22
23
18
19
20
15
16
17
12
13
14
9
10
11
6
7
8
2
3
4
5
Modules supporting 72 lines have a third 50-pin connector that uses connections
Table B-5. Middle connector pin assignments for two-wire connections
(72-port LIM only)
Signal
66R
67R
68R
69R
70R
71R
60R
61R
62R
63R
64R
65R
54R
55R
56R
57R
58R
59R
49R
(channel 1 ring)
50R
51R
52R
53R
Color code
Blue/white
Orange/white
Slate/white
Blue/red
Orange/red
Green/red
Brown/red
Slate/red
Blue/black
Green/black
Brown/black
Slate/black
Blue/yellow
Pin
26
27
Green/white 28
Brown/white 29
30
31
32
33
34
35
36
Orange/black 37
38
39
40
41
Orange/yellow 42
Green/yellow 43
Brown/yellow 44
Slate/yellow 45
Blue/violet 46
Orange/violet 47
Green/violet 48
Signal
49T
(channel 1 tip)
Color code
White/blue
66T
67T
68T
69T
70T
71T
60T
61T
62T
63T
64T
65T
54T
55T
56T
57T
58T
59T
50T
51T
52T
53T
White/orange
White/green
White/brown
White/slate
Red/blue
Red/orange
Red/green
Red/brown
Red/slate
Black/blue
Black/orange
Black/green
Black/brown
Black/slate
Yellow/blue
Yellow/orange
Yellow/green
Yellow/brown
Yellow/slate
Violet/blue
Violet/orange
Violet/green
B-6 Stinger® MS+ Getting Started Guide
Cables and Connectors
LPM cable specifications
Table B-5.
Pin
Middle connector pin assignments for two-wire connections
(72-port LIM only) (Continued)
Signal Color code Pin Signal Color code
24
25
72R
Not used
Brown/violet 49
N/A 50
72T
Not used
Violet/brown
N/A
LPM four-wire cable specifications
A LIM that supports 24 four-wire connections, such as a T1 or E1 module, must use a
48-port LPM. Optionally, a 24-port LPM can be used for any LIM supporting 12 or
fewer four-wire ports. Table B-6 shows the USOC RJ-21X cable pinouts for the lower
50-pin connector for four-wire connection. Table B-7 shows the cable pinouts for the
upper 50-pin connector.
Table B-6. Lower connector pin assignments for four-wire connections
Four-wire interface
7
8
5
6
3
4
1
2
9
10
11
12
Transmit tip
Pin 26
Pin 28
Pin 30
Pin 32
Pin 34
Pin 36
Pin 38
Pin 40
Pin 42
Pin 44
Pin 46
Pin 48
Transmit ring
Pin 1
Pin 3
Pin 5
Pin 7
Pin 9
Pin 11
Pin 13
Pin 15
Pin 17
Pin 19
Pin 21
Pin 23
Receive tip
Pin 27
Pin 29
Pin 31
Pin 33
Pin 35
Pin 37
Pin 39
Pin 41
Pin 43
Pin 45
Pin 47
Pin 49
Receive ring
Pin 2
Pin 4
Pin 6
Pin 8
Pin 10
Pin 12
Pin 14
Pin 16
Pin 18
Pin 20
Pin 22
Pin 24
Stinger® MS+ Getting Started Guide B-7
Cables and Connectors
LPM cable specifications
22
23
24
19
20
21
16
17
18
13
14
15
Table B-7. Upper connector pin assignments for four-wire connections
Four-wire interface
Transmit tip
Transmit ring
Receive tip
Receive ring
Pin 38
Pin 40
Pin 42
Pin 44
Pin 46
Pin 48
Pin 26
Pin 28
Pin 30
Pin 32
Pin 34
Pin 36
Pin 13
Pin 15
Pin 17
Pin 19
Pin 21
Pin 23
Pin 1
Pin 3
Pin 5
Pin 7
Pin 9
Pin 11
Pin 39
Pin 41
Pin 43
Pin 45
Pin 47
Pin 49
Pin 27
Pin 29
Pin 31
Pin 33
Pin 35
Pin 37
Pin 14
Pin 16
Pin 18
Pin 20
Pin 22
Pin 24
Pin 2
Pin 4
Pin 6
Pin 8
Pin 10
Pin 12
B-8 Stinger® MS+ Getting Started Guide
Safety-Related Electrical,
Physical, and Environmental
Information
Special requirements and recommendations for installation and maintenance . C-5
See the Edge Access and Broadband Access Safety and Compliance Guide for safety instructions and country-specific information.
Warning Before installing your Stinger unit, be sure to read the Edge Access and
Broadband Access Safety and Compliance Guide .
C
Electrical and electronic information
Electrical and electronic information for Stinger units includes specifications, universal service order code (USOC) information, ground wire size, and electromagnetic interference (EMI) class.
Electronic and electrical specifications
The Stinger unit is nominally powered from a -48Vdc source. This source is wired to
the power filters on the left side at the front of the chassis. Table C-1 describes Stinger
MS+ electronic and electrical specifications.
Table C-1. Stinger electronic and electrical specifications
Application
-48Vdc
Input voltage
Inrush current
Power cable
Specification
17 amps, 770 watts (W) maximum
-40Vdc to -72Vdc
Minimal because all modules have inrush-limiting circuits
In accordance with national standards and specifications as described in EN/IEC 60950 (CE)
Stinger® MS+ Getting Started Guide C-1
Safety-Related Electrical, Physical, and Environmental Information
Electrical and electronic information
Table C-1.
Application
Stinger electronic and electrical specifications (Continued)
Specification
Connectors
Circuit breaker
Standards
Number 10 terminal lugs
50A
Bellcore GR-1089-CORE, classified A2
USOC jack and code information
Stinger equipment complies with Part 68 of the U.S. Federal Communications
Commission (FCC) Rules and uses the universal service order code (USOC) jack type
and code shown in Table C-2. For information about FCC Part 68, see the
Edge Access and Broadband Access Safety and Compliance Guide .
Table C-2. Stinger T1 module USOC jacks and codes
Model name Service order code Jack type
STGR-LIM-T1-8
STGR-LIM-T1-8
STGR-LIM-T1-8
STGR-LIM-T1-8
STGR-LIM-T1-8
STGR-LIM-T1-24
STGR-LIM-T1-24
STGR-LIM-T1-24
STGR-LIM-T1-24
STGR-LIM-E1-24
STGR-LIM-E1-8
STGR-LIM-E1-8
STGR-LIM-E1-8
STGR-LIM-E1-8
STGR-LIM-E1-8
STGR-LIM-E1-24
STGR-LIM-E1-24
Facility interface code
04DU9-BN
04DU9-DN
04DU9-1KN
04DU9-1SN
04DU9-1ZN
04DU9-BN
04DU9-DN
04DU9-1KN
04DU9-1SN
04DU9-1ZN
04DU9-BN
04DU9-DN
04DU9-1KN
04DU9-1SN
04DU9-1ZN
04DU9-BN
04DU9-DN
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
6.0N
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
RJ-48C
C-2 Stinger® MS+ Getting Started Guide
Safety-Related Electrical, Physical, and Environmental Information
Physical specifications
Table C-2.
Model name
Stinger T1 module USOC jacks and codes (Continued)
Facility interface code
Service order code Jack type
STGR-LIM-E1-24
STGR-LIM-E1-24
STGR-LIM-E1-24
04DU9-1KN
04DU9-1SN
04DU9-1ZN
6.0N
6.0N
6.0N
RJ-48C
RJ-48C
RJ-48C
EMI class
The Stinger product belongs to EMI class A.
Minimum ground wire size
The DSL lines connected to the Stinger FS and Stinger FS+ can be subject to lightning surges. These surges must be discharged to ground through an adequate ground wire.
An adequate ground wire must present a resistance of approximately 0.02 ohms to a
surge of 500 amps. The wire gauges shown in Table C-3 are appropriate for the wire
lengths indicated.
Table C-3. Stinger FS minimum ground wire sizes
Length Wire gauge
0 to 10 feet (0m to 3.05m) 12 AWG (3.31mm²)
10 to 25 feet (3.05m to 7.62m) 9 AWG (6.63mm²)
25 to 50 feet (7.62m to
15.24m)
6 AWG (13.3mm²)
50 to 100 feet (15.24m to
30.48m)
3 AWG (26.7mm²)
Lucent Technologies does not recommend use of a ground wire longer than 100 feet
(30.48m).
Physical specifications
Table C-4 describes the Stinger MS+ physical specifications.
Table C-4. Stinger MS+ physical specifications
Specification
ATM standards
Description
ATM Forum UNI (Version 3.0 and Version 3.1), ATM
Forum Interim Interswitch Signaling Protocol (IISP)
Stinger® MS+ Getting Started Guide C-3
Safety-Related Electrical, Physical, and Environmental Information
Site specifications
Table C-4.
Specification
Stinger MS+ physical specifications (Continued)
Description
WAN interfaces DS3 and E3 (cell-based), OC3c/STM-1 (optical and electrical), T1, E1, and Ethernet
Ethernet and RS-232 Management interfaces
Physical characteristics Basic unit includes two dc power filters, one control module, one trunk module, and up to four pairs of LIMs and LPMs
Overall chassis size a Height: 7 inches (17.78cm)
Depth: 15.35 inches (39cm)
Width: 17.7 inches (44.9cm)
Unit weight a.
66 pounds (30kg) maximum (fully configured)
The depth measurement does not include calculations for cable spacing.
Site specifications
Stinger units require a particular operating environment and minimum clearance for
proper operation (see “Space requirements”).
Operating environment
Table C-5 describes the environmental requirements for selecting an installation site
for the Stinger MS+ hardware. The site requirements are based on Network
Equipment Building System (NEBS) GR-63-CORE and GR-1089-CORE.
Table C-5. Stinger MS+ site specifications
Requirement
0°C to 55°C (32°F to 131°F)
Parameter
Ambient operating temperature
Relative humidity
Operating altitude
Ambient storage temperature
Storage altitude
10% to 95% (noncondensing)
To 13,123 feet (4000m)
-40°C to +85°C (-40°F to +185°F), 95% relative humidity
-1,000 feet to +30,000 feet (-305m to 9150m)
C-4 Stinger® MS+ Getting Started Guide
Safety-Related Electrical, Physical, and Environmental Information
Special requirements and recommendations for installation and maintenance
Space requirements
The Stinger MS+ hardware requires the following minimum clearances for the chassis:
■
■
20 inches (54cm) at the front panel for module replacement and cable routing
16 inches (40.6cm) at the back panel for module replacement and cable routing
■ 3 in. (75mm) on either side of the chassis for airflow recommended (2 in. [50mm] min.)
Special requirements and recommendations for installation and maintenance
Follow these requirements and recommendations for Stinger installation and maintenance.
Lifting requirements
Use a mechanical lift or at least two people to lift a fully loaded Stinger MS+ chassis
for rack mounting. For more information, see “Mounting the unit” on page 2-1.
Stinger® MS+ Getting Started Guide C-5
Index
A activity, system
addresses, IP assigning for Ethernet
syntax
admin login, recommended password change
administrative access, restricting
administrative connections
alarm input description
pinouts
alarm monitoring alarm module
Stinger monitoring other devices
alarm relays, connecting to monitor other devices
to monitor the Stinger
altitude operating
storage
ATM, standards
B backup management via external modem
backups
BITS clock source changing
loss of
using
C cables
100Base-T
10Base-T
connecting
diagnostic port
LPM four-wire
Stinger® MS+ Getting Started Guide
LPM two-wire
serial port
changing default logins
chassis size
clock source
BITS
connecting inputs and outputs
LIM
modes
trunk ports
command help
command-line interface, introduced
commands
Dir
listing
Ping
Read and Write
Set
STATUS
configuration basic IP
initial serial port login
overview
connecting clock inputs and outputs
power cord to -48 Vdc power supply
console terminal, connecting and setting up
control module functions
interfaces checking
control modules cautions about replacing
configuration overview
installing and replacing
interface-independent address
primary, logging into
status lights
cooling module status lights
D default route, IP
Index-1
Index
E
serial port
DS3-ATM trunk modules checking
clock source
clock source settings
connecting
DSLAM, diagram of operations
E
E3-ATM trunk modules checking
clock-source
connecting
electronic specifications
electrostatic discharge (ESD) jack
EMI class
environmental specifications
ESD, grounding jack
Ethernet interface specifications
required equipment
Ethernet ports
IP addresses
on control modules
F fault tolerance controller IP address
flash memory backups
upgrades
G ground wire size
H hardware, verifying configuration
humidity requirement
I installation completing
considerations
Index-2 modules
mounting the unit
preparing the site
prerequisites
required tools
selecting a site
intended use
IP address syntax
addresses for control module Ethernet ports
default route
host routes
minimal configuration
soft interface address
subnet notation
IP2000 control module
IP-Global profile
IP-Interface profile
IP-Route profiles
L
LAN connection
LAN UTP port interface
See status lights lifting requirements
LIM configuration overview
function
installing and replacing
logging into the Stinger
LPM connecting
four-wire pinouts
function
installing and replacing
two-wire pinouts
M management backup connection via external modem
backup connection via internal modem
features
types of connections supported
modems country codes
dial-in management through
modules
installation and replacement considerations
Stinger® MS+ Getting Started Guide
N netmask
O
OC3-ATM trunk modules checking
clock source
clock-source settings
connecting
online help, commands
P passwords changing defaults
Telnet
PCMCIA cards described
installing and replacing
permission levels
pinouts alarm input
LPM four-wire
LPM two-wire
plug-in components control module
LIM
LPM
power filter
power filter function
power supplies
-48 Vdc, connecting power to
powering up, described
preventing static discharge damage
control modules profiles
IP-Global
IP-Interface
IP-Route
modem
Serial
User
Stinger® MS+ Getting Started Guide
Index
N
R rack-mounting the unit
S security changing admin password
changing default logins
Telnet password
serial port initial login to unit
restricting access
Serial profile
size of chassis
slot numbering
SNMP support
soft interface address
space requirements
specifications cable pinouts
electrical
EMI class
environmental
Ethernet interface
physical
space
special requirements and recommendations
USOC jack and code
startup sequence
static discharge damage
preventing
status lights control module
cooling module
status windows, displaying
subnet mask
subnet notation
subscriber lines connecting
system activity, tracking
T
Telnet password
temperature operating
storage
terminal emulation settings, required
Index-3
Index
U
TFTP, downloading files
timing subsystem
tools and equipment required for installation
TRAM module checking
trunk modules clock source
configuration overview
overview
See also DS3-ATM trunk modules
See also OC3-ATM trunk modules
U unpacking the unit
use of wrist strap
user interface, terminal configuration for
User profile
USOC jack and code information
V vendor-specific attribute (VSA) requirements,
RADIUS
W
WAN interfaces supported
weight of unit
workstation, connecting
Index-4 Stinger® MS+ Getting Started Guide
Tải xuống
Quảng cáo