advertisement
O N T P R O D U C T I N F O R M A T I O N G U I D E
Alcatel-Lucent 7330
INTELLIGENT SERVICES ACCESS MANAGER FIBER TO THE NODE
ONT R04.02.41
Alcatel-Lucent 7302
INTELLIGENT SERVICES ACCESS MANAGER | ONT R04.02.41
O N T P R O D U C T I N F O R M A T I O N G U I D E
3FE 54017 AAAA TCZZA Edition 01
Alcatel-Lucent Proprietary
This document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements.
Copyright 2010 © Alcatel-Lucent. All rights reserved.
Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is subject to change without notice.
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
Copyright 2010 Alcatel-Lucent.
All rights reserved.
Disclaimers
Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications.
This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products.
However, this does not constitute a representation or warranty. The warranties provided for
Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by
Alcatel-Lucent and its customers.
This document was originally written in English. If there is any conflict or inconsistency between the
English version and any other version of a document, the English version shall prevail.
When printed by Alcatel-Lucent, this document is printed on recycled paper.
Preface
This preface provides general information about the documentation set for optical network terminals (ONTs).
Scope
This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, and software installation procedures for the current release.
Audience
This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the ONTs.
Required knowledge
The reader must be familiar with general telecommunications principles.
Acronyms and initialisms
The expansions and optional descriptions of most acronyms and initialisms appear in the glossary.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide iii
Preface
Assistance and ordering phone numbers
Alcatel-Lucent provides global technical support through regional call centers.
Phone numbers for the regional call centers are available at the following URL: http://www.alcatel-lucent.com/myaccess.
For ordering information, contact your Alcatel-Lucent sales representative.
Alcatel-Lucent quality processes
Alcatel-Lucent’s ONT manufacturing, testing, and inspecting practices are in compliance with GR-1252-CORE and TL 9000 requirements. These requirements are documented in the Operations Quality Plan 8BD-00023-4204-QRZZA, the
Alcatel North American Quality Manual 8BD-00001-0000-QRZZA, and the
Wireline Network Quality Manual 8AB-83179-0001-QRAAA.
The quality plans and practices adequately ensure that technical requirements and customer end-point requirements are met. The customer or its representatives may be allowed to perform on-site quality surveillance audits, as agreed upon during contract negotiations.
Safety information
For safety information, see the appropriate safety guidelines chapter.
Documents
Documents are available using ALED or OLCS.
Procedure 1 To download an CD-ROM ISO image or ZIP file package of the customer documentation
1 Navigate to http://www.alcatel-lucent.com/myaccess and enter your user name and password. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative.
2 From the Technical Content for drop-down menu, choose the product.
3 Click on Downloads: Electronic Delivery.
4 Choose Documentation from the drop-down menu and click Next.
5 Select the image from the drop-down menu and click Next.
6 Follow the onscreen directions to download the file.
iv December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
Preface
Procedure 2 To access individual documents
Individual PDFs of customer documents are also accessible through the Alcatel-Lucent
Customer Support website.
1 Navigate to http://www.alcatel-lucent.com/myaccess and enter your user name and password. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative.
2 From the Technical Content for drop-down menu, choose the product.
3 Click on Manuals and Guides to display a list of customer documents by title and part number. You can filter this list using the Release drop-down menu.
4 Click on the PDF to open or save the file.
Special information
The following are examples of how special information is presented in this document.
Danger — Danger indicates that the described activity or situation may result in serious personal injury or death; for example, high voltage or electric shock hazards.
Warning — Warning indicates that the described activity or situation may, or will, cause equipment damage or serious performance problems.
Caution — Caution indicates that the described activity or situation may, or will, cause service interruption.
Note — A note provides information that is, or may be, of special interest.
Procedures with options or substeps
When there are options in a procedure, they are identified by letters. When there are required substeps in a procedure, they are identified by roman numerals.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide v
Preface vi
Procedure 3 Example of options in a procedure
At step
, you can choose option a or b. At step
2 , you must do what the step indicates.
1 This step offers two options. You must choose one of the following: a This is one option.
b This is another option.
2 You must perform this step.
Procedure 4 Example of required substeps in a procedure
At step
, you must perform a series of substeps within a step. At step
, you must do what the step indicates.
1 This step has a series of substeps that you must perform to complete the step. You must perform the following substeps: i This is the first substep.
ii This is the second substep.
iii This is the third substep.
2 You must perform this step.
Multiple PDF document search
You can use Adobe Reader Release 6.0 and later to search multiple PDF files for a common term. Adobe Reader displays the results in a single display panel. The results are grouped by PDF file, and you can expand the entry for each file.
Note — The PDF files in which you search must be in the same folder.
Procedure 5 To search multiple PDF files for a common term
1 Open Adobe Acrobat Reader.
2 Choose Edit → Search from the Acrobat Reader main menu. The Search PDF panel appears.
3 Enter the search criteria.
4 Click on the All PDF Documents In radio button.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
Preface
5 Select the folder in which to search using the drop-down menu.
6 Click on the Search button.
Acrobat Reader displays the search results. You can expand the entries for each document by clicking on the + symbol.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide vii
Preface viii December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
ETSI ONT safety guidelines
This chapter provides information about the mandatory regulations that govern the installation and operation of the optical network terminals (ONTs).
Safety instructions
This section describes the safety instructions that are provided in the ONT customer documentation and on the equipment.
Safety instruction boxes
The safety instruction boxes are provided in the ONT customer documentation.
Observe the instructions to meet safety requirements.
The following is an example of the Danger box.
Danger — Possibility of personal injury.
The Danger box indicates that the described activity or situation may pose a threat to personal safety. It calls attention to a situation or procedure which, if not correctly performed or adhered to, may result in death or serious physical harm.
Do not proceed beyond a Danger box until the indicated conditions are fully understood and met.
The following is an example of the Warning box.
Warning 1 — Possibility of equipment damage.
Warning 2 — Possibility of data loss.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide ix
ETSI ONT safety guidelines
The Warning box indicates that the described activity or situation may, or will, cause equipment damage, loss of data, or serious performance problems. It identifies a possible equipment-damaging situation or provides essential information to avoid the degradation of system operations or data.
Do not proceed beyond a warning until the indicated conditions are fully understood and met.
The following is an example of the Caution box.
Caution 1 — Possibility of service interruption.
Caution 2 — Service interruption.
The Caution box indicates that the described activity or situation may, or will, cause service interruption.
Do not proceed beyond a caution until the indicated conditions are fully understood and met.
The following is an example of the Note box.
Note — Information of special interest.
The Note box provides information that assists the personnel working with ONTs. It does not provide safety-related instructions.
Safety-related labels
The ONT equipment is labeled with the specific safety instructions and compliance information that is related to a variant of the ONT. Observe the instructions on the safety labels.
Table
1 provides sample safety labels on the ONT equipment.
Description
ESD warning
Laser classification
PSE marking
Table 1 Safety labels
Label text
Caution: This assembly contains an electrostatic sensitive device.
Class 1 laser product
These power supplies are Japan PSE certified and compliant with
Japan VCCI emissions standards.
shows the PSE certification.
x December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
ETSI ONT safety guidelines
Figure 1 PSE certification
Warning
This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.
19841
Safety standards compliance
This section describes the ONT compliance with the European safety standards.
EMC, EMI, and ESD compliance
The ONT equipment complies with the following EMC, EMI, and ESD requirements:
• EN 300-386 V1.3.2 (2003-05): Electromagnetic Compatibility and Radio
Spectrum Matters (ERM): Telecommunications Network Equipment;
Electromagnetic Compatibility (EMC) requirements; Electrostatic Discharge
(ESD) requirements
• EN 55022 (1998): Class B, Information Technology Equipment, Radio
Disturbance Characteristics, limits and methods of measurement
• EN 55024 (1998): Information Technology Equipment, Immunity
Characteristics, limits and methods of measurement
• European Council Directive 2004/108/EC
• EN 300-386 V1.4.1: 2008
• EN 55022:2006 Class B (ONTs)
• EN EN 61000-3-2:2006
• EN EN 61000-3-3:2008
• IEC 61000-4-2:2001
• IEC 61000-4-3:2006
• IEC 61000-4-4:2004
• IEC 61000-4-5:2005
• IEC 61000-4-6:2003/A1:2004/A2:2006
• IEC 61000-4-11:2004
Equipment safety standard compliance
The ONT equipment complies with the requirements of EN 60950-1, Safety of
Information Technology Equipment for use in a restricted location (per R-269).
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide xi
ETSI ONT safety guidelines
Environmental standard compliance
The ONT equipment complies with the EN 300 019 European environmental standards.
Laser product standard compliance
The ONT equipment complies with EN 60825-1 and IEC 60825-2 for laser products.
Resistibility requirements compliance
The ONT equipment complies with the requirements of ITU Recommendation K.21 for resistibility of telecommunication equipment installed in customer premises to over voltage and overcurrents.
Acoustic noise emission standard compliance
The ONT equipment complies with EN 300 753 acoustic noise emission limit and test methods.
Electrical safety guidelines
This section provides the electrical safety guidelines for the ONT equipment.
Note 1 — The ONTs comply with the U.S. National Electrical Code.
However, local electrical authorities have jurisdiction when there are differences between the local and U.S. standards.
Note 2 — The ONTs comply with BS EN 61140.
Power supplies
The use of any non-Alcatel-Lucent approved power supplies or power adaptors is not supported or endorsed by Alcatel-Lucent. Such use will void any warranty or support contract with Alcatel-Lucent. Such use greatly increases the danger of damage to equipment or property.
Cabling
The following are the guidelines regarding cables used for the ONT equipment:
• All cables must be approved by the relevant national electrical code.
• The cables for outdoor installation of ONTs must be suitable for outdoor use.
• POTS wiring run outside the subscriber premises must comply with the requirements of local electrical codes. In some markets, the maximum allowed length of the outside run is 140 feet (43 m). If the outside run is longer, NEC requires primary protection at both the exit and entry points for the wire.
xii December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
ETSI ONT safety guidelines
Protective earth
Earthing and bonding of the ONTs must comply with the requirements of local electrical codes.
ESD safety guidelines
The ONT equipment is sensitive to ESD. Operations personnel must observe the following ESD instructions when they handle the ONT equipment.
Caution — This equipment is ESD sensitive. Proper ESD protections should be used when you enter the TELCO Access portion of the
ONT.
During installation and maintenance, service personnel must wear wrist straps to prevent damage caused by ESD.
Laser safety guidelines
Observe the following instructions when you perform installation, operations, and maintenance tasks on the ONT equipment.
Only qualified service personnel who are extremely familiar with laser radiation hazards should install or remove the fiber optic cables and units in this system.
Danger — There may be invisible laser radiation at the fiber optic cable when the cable is removed from the connector. Avoid direct exposure to the laser beam.
Observe the following danger for laser hazard. Eyes can be damaged when they are exposed to a laser beam. Take necessary precautions before you plug in the optical modules.
Danger — Possibility of equipment damage. Risk of eye damage by laser radiation.
Laser classification
The ONT is classified as a Class 1 laser product based on its transmit optical output.
Laser warning labels
The following figures show the labels related to laser product, classification and warning.
shows a laser product label.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide xiii
ETSI ONT safety guidelines
Figure 2 Laser product label
shows a laser classification label. Laser classification labels may be provided in other languages.
18455
Figure 3 Laser classification label
CLASS 1 LASER PRODUCT
LASER CLASSE 1
18992
shows a laser warning label and an explanatory label for laser products.
Labels and warning may be provided in other languages. The explanatory label provides the following information:
• a warning that calls attention to the invisible laser radiation
• an instruction against staring into the beam or viewing directly with optical instruments
• wavelength
• normal output power
• maximum output power xiv December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
ETSI ONT safety guidelines
Figure 4 Laser warning labels
Laser Warning Label
INVISIBLE LASER RADIATION
DO NOT STARE INTO BEAM
OR VIEW DIRECTLY WITH
OPTICAL INSTRUMENTS
Wavelength(s): xxxx nm
Normal output power: xx m W
Max output power: yyy m W
Laser Warning Label
CLASS 1 LASER PRODUCT
RAYONNEMENT LASER CLASSE 1
RAYONNEMENT LASER INVISIBLE
'
EVITER TOUTE EXPOSITION AU FAISCEAU
NE PAS DEMONTER. FAIRE APPEL A UN PERSONNELL QUALIFIE
CLASE 1 DEL LASER
RADIACION DE LASER INVISIBLE. EVITAR CUALOUIER EXPOSICION AL
RAYO LASER. NO DESMONTAR. LLAMAR A PERSONAL AUTORIZADO
INVISIBLE LASER RADIATION PRESENT AT FIBER OPTIC CABLE
WHEN NOT CONNECTED. AVOID DIRECT EXPOSURE TO BEAM.
Laser Warning Label
18993
Transmit optical output
The maximum transmit optical output of an ONT is +5 dBm.
Normal laser operation
In normal operation, fiber cable laser radiation is always off until it receives signal from the line terminal card.
Eyes can be damaged when they exposed to a laser beam. Operating personnel must observe the instructions on the laser explanatory label before plugging in the optical module.
Danger — Risk of eye damage by laser radiation.
Location class
Use cable supports and guides to protect the receptacles from strain.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide xv
ETSI ONT safety guidelines
Environmental requirements
See the ONT technical specification documentation for more information about temperature ranges.
During operation in the supported temperature range, condensation inside the ONT caused by humidity is not an issue. To avoid condensation caused by rapid changes in temperature and humidity, Alcatel-Lucent recommends:
• The door of the ONT not be opened until temperature inside and outside the enclosure has stabilized.
• If the door of the ONT must be opened after a rapid change in temperature or humidity, use a dry cloth to wipe down the metal interior to prevent the risk of condensation.
• When high humidity is present, installation of a cover or tent over the ONT helps prevent condensation when the door is opened.
xvi December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
ETSI environmental and CRoHS guidelines
This chapter provides information about the ETSI environmental China Restriction of Hazardous Substances (CRoHS) regulations that govern the installation and operation of the optical line termination (OLT) and optical network termination
(ONT) systems. This chapter also includes environmental operation parameters of general interest.
Environmental labels
This section describes the environmental instructions that are provided with the customer documentation, equipment, and location where the equipment resides.
Overview
CRoHS is applicable to Electronic Information Products (EIP) manufactured or sold and imported in the territory of the mainland of the People’s Republic of China. EIP refers to products and their accessories manufactured by using electronic information technology, including electronic communications products and such subcomponents as batteries and cables.
Environmental related labels
Environmental labels are located on appropriate equipment. The following are sample labels.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide xvii
ETSI environmental and CRoHS guidelines
Products below Maximum Concentration Value (MCV) label
shows the label that indicates a product is below the maximum concentration value, as defined by standard SJ/T11363-2006 (Requirements for
Concentration Limits for Certain Hazardous Substances in Electronic Information
Products). Products with this label are recyclable. The label may be found in this documentation or on the product.
Figure 1 Products below MCV value label
18986
Products containing hazardous substances above Maximum Concentration
Value (MCV) label
shows the label that indicates a product is above the maximum concentration value, as defined by standard SJ/T11363-2006 (Requirements for
Concentration Limits for Certain Hazardous Substances in Electronic Information
Products). The number contained inside the label indicates the
Environment-Friendly User Period (EFUP) value. The label may be found in this documentation or on the product.
xviii December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
ETSI environmental and CRoHS guidelines
Figure 2 Products above MCV value label
18985
Together with major international telecommunications equipment companies,
Alcatel-Lucent has determined it is appropriate to use an EFUP of 50 years for network infrastructure equipment and and EFUP of 20 years for handsets and accessories. These values are based on manufacturers' extensive practical experience of the design, manufacturing, maintenance, usage conditions, operating environments, and physical condition of infrastructure and handsets after years of service. The values reflect minimum values and refer to products operated according
to the intended use conditions. See “Hazardous Substances Table (HST)”
for more information.
Hazardous Substances Table (HST)
This section describes the compliance of the OLT and ONT equipment to the CRoHS standard when the product and subassemblies contain hazardous substances beyond the MCV value. This information is found in this user documentation where part numbers for the product and subassemblies are listed. It may be referenced in other
OLT and ONT documentation.
In accordance with the People’s Republic of China Electronic Industry Standard
Marking for the Control of Pollution Caused by Electronic Information Products
(SJ/T11364-2006), customers may access the Alcatel-Lucent Hazardous Substance
Table, in Chinese, from the following location:
• http://www.alcatel-sbell.com.cn/wwwroot/images/upload/private/1/media/ChinaR oHS.pdf
Other environmental requirements
Observe the following environmental requirements when handling the P-OLT or
ONT equipment.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide xix
ETSI environmental and CRoHS guidelines
ONT environmental requirements
See the ONT technical specification documentation for more information about temperature ranges.
Storage
According to ETS 300-019-1-1 - Class 1.1, storage of OLT equipment must be in
Class 1.1, weather-protected, temperature-controlled locations.
Transportation
According to EN 300-019-1-2 - Class 2.3, transportation of the OLT equipment must be in packed, public transportation with no rain on packing allowed.
Stationary use
According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of OLT equipment must be in a temperature-controlled location, with no rain allowed, and with no condensation allowed.
Thermal limitations
When the OLT is installed in the CO or CEV, install air filters on the P-OLT. The thermal limitations for OLT operation in a CO or CEV are:
• operating temperature: 5
°
C to 40
°
C (41
°
F to 104
°
F)
• short-term temperature: –5
°
C to 50
°
C (23
°
F to 122
°
F)
• operating relative humidity: 5% to 85%
• short-term relative humidity: 5% to 95%, but not to exceed 0.024 kg of water/kg
Material content compliance
European Union (EU) Directive 2002/95/EC, “Restriction of the use of certain
Hazardous Substances” (RoHS), restricts the use of lead, mercury, cadmium, hexavalent chromium, and certain flame retardants in electrical and electronic equipment. This Directive applies to electrical and electronic products placed on the
EU market after 1 July 2006, with various exemptions, including an exemption for lead solder in network infrastructure equipment. Alcatel-Lucent products shipped to the EU after 1 July 2006 comply with the EU RoHS Directive.
xx December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
ETSI environmental and CRoHS guidelines
End-of-life collection and treatment
Electronic products bearing or referencing the symbol shown in Figure
on the market within the European Union (EU), shall be collected and treated at the end of their useful life, in compliance with applicable EU and local legislation. They shall not be disposed of as part of unsorted municipal waste. Due to materials that may be contained in the product, such as heavy metals or batteries, the environment and human health may be negatively impacted as a result of inappropriate disposal.
Note — In the European Union, a solid bar under the symbol for a crossed-out wheeled bin indicates that the product was put on the market after 13 August 2005.
Figure 3 Recycling/take back/disposal of product symbol
At the end of their life, the OLT products are subject to the applicable local legislations that implement the European Directive 2002/96EC on waste electrical and electronic equipment (WEEE).
There can be different requirements for collection and treatment in different member states of the European Union.
In compliance with legal requirements and contractual agreements, where applicable, Alcatel-Lucent will offer to provide for the collection and treatment of
Alcatel-Lucent products bearing the logo shown in Figure 3
at the end of their useful life, or products displaced by Alcatel-Lucent equipment offers. For information regarding take-back of equipment by Alcatel-Lucent, or for more information regarding the requirements for recycling/disposal of product, contact your
Alcatel-Lucent account manager or Alcatel-Lucent take back support at [email protected].
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide xxi
ETSI environmental and CRoHS guidelines xxii December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
ONT and MDU general system overview
2 — Part numbers, ordering, and deployment configuration overview
3 — ONT and MDU general and interface technical specifications
4 — ONT and MDU statistics and performance monitoring
5 — ONT management using an ONT interface
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
1.1 ONT and MDU general descriptions of features and functions 1-2
1.2 ONT and MDU software architecture and protocols 1-13
1.3 GPON transmission support 1-14
1.4 ONT activation and behavior using SLID 1-16
1.5 ONT management at a local site 1-17
1.6 ONT configuration using a web-based interface 1-19
1.7 ONT physical security 1-20
1.9 802.1x authentication 1-22
1.10 Anti-spoofing mechanism 1-24
1.12 ONT and MDU interface connection limitations 1-27
1.13 Other ONT limitations 1-28
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-1
1 — ONT and MDU overview
1.1
ONT and MDU general descriptions of features and functions
The ONT and MDU are part of a family of products that provide “last mile” broadband access solutions. The products work together to form a fiber access network capable of delivering high quality voice, video, and data services to both single-family and multi-dwelling residential subscribers.
The Alcatel-Lucent ONT and MDU products are edge devices that use GPON technology to extend a fiber optic cable from a P-OLT shelf at a CO to a subscriber residence, including single-family residences, multi-dwelling residences such as an apartment building, and small office applications.
The ONT product family consists of the following:
• Packet Optical Line Terminations (P-OLTs)
• ONTs that include:
• business focused models
• residential models (indoor, outdoor)
• multi-dwelling unit models (MDU)
• Element Management System (EMS), including: a simple web-based management system and a sophisticated network management system
P-OLTs
The P-OLT resides in the central office (CO) or controlled environment vault (CEV) and provides interfaces between the network and the gigabit passive optical network
(GPON).
Business ONTs
The business ONT terminates services at the subscriber’s premises and is suitable for a mix of small to medium business as well as residential applications. The business
ONT provides voice, data and IP video, and optional RF video services to subscribers and supports CES DS1 or E1 connections at the business premises.
Business ONTs also provide a single entry point for voice, data, and video services at the subscriber’s premises and multiplexes E1 traffic with Ethernet data across the
GPON.
Indoor ONTs
The indoor ONT terminates services at the subscriber’s premises and is used for single-family residences. The indoor ONT is suitable for installation on a desktop or for attaching to an interior wall.
MDUs
The multi-dwelling unit ONT terminates services at the subscriber’s premises and is suitable for apartment, condominium, and small office or home office (SOHO) applications. MDUs support VDSL2 interfaces and Ethernet interfaces.
1-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
Outdoor ONTs
The outdoor ONT terminates services at the subscriber’s premises and is used for single-family residences. The outdoor ONT is suitable for installation outside the building and has a tamper-resistant design and an environmentally-hardened enclosure.
EMS
The EMS software system use GUI interfaces to provide element management functions for the OLTs and ONTs.
ONTs and MDUs per package type
The ONT product family is categorized into package types based on the similar features and functions that are supported by the hardware on the 7302 ISAM /
7330 ISAM FTTN converged platform.
All ONTs and MDUs comply with the following standards:
• Dynamic Bandwidth Allocation (DBA) for sharing amongst multiple users while maintaining QoS
• Forward Error Correction (FEC) for longer reach upstream and downstream
• Advanced Encryption System (AES) for downstream and upstream data security
• ONT Management Control Interface (OMCI) for ONT management and provisioning
The common features and functions for ONTs and MDUs include the following:
• GEM mode support for efficient IP/Ethernet service traffic transport
• GPON interface capable of 1.244 Gb/s upstream and 2.488 Gb/S downstream line rates
• integrated triplexers or bidirectional transceivers for single fiber with 1490 nm wavelength downstream, 1310 nm wavelength upstream, and optional 1550 nm downstream for RF video overlay and/or MoCA service (on some models)
• class B+ 28 dB link loss budget with up to 20km (12.43 mi) reach
• CES encapsulation of DS1/E1 using the MEF-8 packetization format for transport across the layer 2 Ethernet PON
• interworking functions between the PON optical overlay and the RF video interface (on some models)
• voice interworking function from the analog POTS lines to the VoIP/Ethernet layers
• mux and demux functions to the PON
• interworking functions between the PON optical overlay and the RF video interface (on some models)
• voice interworking functions between the GEM and Ethernet layers
• support for up to 1:64 splits per PON
• single mode fiber (SC/APC) connector and optional Opti-Tap connector (on some models)
• optical-to-electrical conversion
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-3
1 — ONT and MDU overview
• network demarcation for all services
• PON reach capacity: minimum 18.6 mi (30 km) and maximum 37.3 mi (60 km) depending on the optical budget supported by the LT card used, the PON reach specified based on network deployments, and the losses of optical fiber, connectors, and splitters, and so on.
Table
1-1 lists the ONTs and MDUs categorized into package types and describes
the specific features, functions and limitations.
Warning — Existing ONTs that use 7342 ISAM FTTU releases older than R04.06.xx and R04.07.xx must be upgraded to use R04.00.10 software while assigned to a PON ID value smaller than 64. For this purpose, if split ratios larger than 1:64 are being deployed, you may choose to set aside the first PON ID as a staging point.
Table 1-1 ONTs and MDUs general descriptions per package type
Package
type
A
ONT or MDU mnemonic
I-010G-A
I-020E-B
I-020E-H
I-020G-F
I-220E-A
I-241G-A
O-421E-B
See UDS chapter
12
18
9
9
7
9
Features and functions
AES with operator enable/disable per port-ID level
Single mode fiber and use 2x5 SFF
SC/APC optical port
Optical budget of 28 dB (without
FEC) and an Rx optical sensitivity of -27 dB
Considerations and limitations
See Package A ONT considerations and limitations
FEC is not supported on the following
ONTs:
• I-020E-B
• I-020E-H
• I-020E-B
• O-421E-B
(1 of 6)
1-4 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
Package
type
B
ONT or MDU mnemonic
I-240G-B
I-241G-B
I-010G-B
See UDS chapter
8
Features and functions
Single mode fiber and use 2x5 SFF
SC/APC optical port
Optical budget of 28 dB (without
FEC) and an Rx optical sensitivity of -27 dB
ITU-IT G.984-compliant framing
G.984.3-compliant multicast using a single GEM port-ID for all video traffic
AES with operator enable/disable per port-ID level
AES 128 decryption with key generation and switching
Single T-CONT and multiple
T-CONT mode
Flexible mapping between GEM ports and T-CONTs
Mapping of GEM ports into a
T-CONT with priority queues-based scheduling
Multicast GEM ports per device
DBA reporting in status indications in the Physical Layer Overhead
Upstream burst (PLOu), and by piggyback reports in the Dynamic
BAndwidth Report Upstream
(DBRu) for mode 0
G.984.3-compliant activation with automatic discovery of a serial number and a password
802.1p mapper service profile on the upstream
Considerations and limitations
See Package B ONT considerations and limitations
(2 of 6)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-5
1 — ONT and MDU overview
Package
type
C
D
E
ONT or MDU mnemonic
I-010G-P
I-010G-Q
I-011G-P
I-020G-P
I-040G-P
I-110G-P
I-240G-P
I-241G-P
I-240G-Q
I-241W-P
I-440G-P
—
All
See UDS chapter
10
11
15
15
–
10
–
10
15
16
17
—
—
Features and functions
ITU-T G.984-compliant framing
G 984.3-compliant multicast using a single GEM port-ID for all video traffic
Single T-CONT and multiple
T-CONT mode
AES with operator enable/disable per port-ID level
AES 128 decryption with key generation and switching
12 GEM ports per Ethernet UNI; see specific UDS
Flexible mapping between GEM ports and T-CONTs
Mapping of GEM ports into a
T-CONT with priority queues-based scheduling
Multicast GEM ports per device
DBA reporting in status indications in the Physical Layer Overhead
Upstream burst (PLOu), and by piggyback reports in the Dynamic
BAndwidth Report Upstream
(DBRu) for mode 0
G.984.3-compliant activation with automatic discovery of a serial number and a password
802.1p mapper service profile on the upstream
Package D ONTs are not currently supported on the converged platform
Common Package E features and functions:
• 100 Mb/s downstream and 100
Mb/s upstream VDSL2 line rate
• configurable VDSL2 interfaces on a 24-pin AMP connector
• fast Ethernet 10/100Base-T ports compliant with IEEE
802.3
• one MGMT port with RJ-45 connector for 100/1000Base-T
Ethernet connection
• deployment in an enclosure that wall mounts on a mounting bracket
• FSAN GPON standards-compliant ONT for
MDU
Considerations and limitations
See Package C ONT considerations and limitations
—
—
(3 of 6)
1-6 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
Package
type
ONT or MDU mnemonic
O-8881V-P
See UDS chapter
—
Features and functions
O-00240V-P 21
8 configurable VDSL2 interfaces on a 24-pin AMP connector
One analog RF video over coaxial connection with a dedicated wavelength of 1550 nm
VDSL2 system support for loop lengths of 300 m (984 ft)
VDSL2 service compliant with
ITU-T standard G.993.2
24 VDSL2 (30MHz) ports
Deployment scenario of horizontal
19 in rack mounting and cabinet mounting
802.1x service authentication support
1640 ft (500 m) target loop length
VDSL service using up to 2 Alloc-IDs and 5 Port-IDs per VDSL port
(assuming equal distribution across all 16 or 24 VDSL ports
Save Data button on the front panel (but also accessible from a network manager) that activates a script for collecting relevant data and transferring it into a reserved area of flash memory
Maximum of 8 CoS per VDSL2 port
(per 802.1p mapping
Considerations and limitations
—
—
(4 of 6)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-7
1 — ONT and MDU overview
Package
type
F
G
ONT or MDU mnemonic
O-00160V-Q
O-00240V-Q
O-0881V-A
See UDS chapter
20
21
19
Features and functions
16 or 24 VDSL2 (30MHz) ports
FSAN GPON standards-compliant
ONT for MDU
Deployment scenario of horizontal
19 in rack mounting and cabinet mounting
802.1x service authentication support
1640 ft (500 m) target loop length
VDSL service using up to 2 Alloc-IDs and 5 Port-IDs per VDSL port
(assuming equal distribution across all 16 or 24 VDSL ports
Save Data button on the front panel (but also accessible from a network manager) that activates a script for collecting relevant data and transferring it into a reserved area of flash memory
Maximum of 8 CoS per VDSL2 port
(per 802.1p mapping
100 Mb/s downstream and 100
Mb/s upstream VDSL2 line rate configurable VDSL2 interfaces on a
24-pin AMP connector fast Ethernet 10/100Base-T ports compliant with IEEE 802.3
one MGMT port with RJ-45 connector for 100/1000Base-T
Ethernet connection deployment in an enclosure that wall mounts on a mounting bracket
AES with operator enable/disable per port-ID level
8 configurable VDSL2 interfaces on a 24-pin AMP connector
8 Fast Ethernet 10/100 Base-T ports compliant with IEEE 802.3
FSAN GPON standards-compliant
ONT for MDU
Deployment in an enclosure that wall mounts on a mounting bracket
Save Data button on the front panel (but also accessible from a network manager) that activates a script for collecting relevant data and transferring it into a reserved area of flash memory
One coaxial port with an operating wavelength range of 1550 nm to
1560 nm
Considerations and limitations
—
See Package G ONT considerations and limitations
(5 of 6)
1-8 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
Package
type
H
ONT or MDU mnemonic
B-0404-A
See UDS chapter
6
Features and functions
G.984.3 compliant AES with operator enable/disable on per port-ID level
802.3 compliant
10/100/1000BASE-T Ethernet interfaces using RJ-45 ports four E1/T1 interfaces using RJ-48C ports
MEF-8 packetization for TDM transport over GPON subscriber location ID (SLID)
IP video with multistage IGMPv3 or
IGMPv2 snooping up to 64 video multicast streams shared by 4 GbE ports
G.984.3-compliant multicast using a single GEM Port-ID for all video traffic
Considerations and limitations
See Package H ONT considerations and limitations
(6 of 6)
Package A ONT considerations and limitations
Table
1-2 lists the considerations and limitations for Package A ONTs.
Table 1-2 Package A ONT considerations and limitations
Considerations and limitations
No support for per VLAN protocol downstream tagging mode
In SVLAN cross-connect tunnel mode:
• use non-overlapping pbits since the use of the same pbits on two or more VLAN ports results in a mismatch alarm
• downstream frames sent with a single tag normally sent out on the user-side as untagged, will instead be sent as priority tagged
When using CVLAN translation, or when the same queue is used for multiple pbits, the highest pbit value in the queue in the downstream direction will be selected to stomp the pbit in the packet
Simultaneous configuration of a CVLAN port and an S-Tunnel on the same UNI will only be supported if these services are provisioned with non-overlapping pbits
The same VLAN port must be used when employing both protocol-based VLAN for PPPoE and
IPoE-based VLANs
When the VLAN is translated, the pbit value must be modified and the highest pbit value is mapped to that GEM port
When more than one Ethernet port is in VLAN translation mode, or set to flexible mode with IGMP channels created, the USERSIDE VLAN IDs of those services are different. All downstream multicast packets will be tagged on the UNI port with VLAN ID of 4094
Maximum use of multicast on 1 Ethernet port at a time
For C forwarder and S+C CC forwarder, if the VLAN port uses regenerated profiles or regenerated pbits, then the downstream traffic can only flow with the derived pbits
(1 of 2)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-9
1 — ONT and MDU overview
Considerations and limitations
When either tip or ring is grounded, DGNONTPOTS tip to ground and ring to ground restrictive measurements are simultaneously reported as 0 ohms
(2 of 2)
Package B ONT considerations and limitations
Table
1-3 lists the considerations and limitations for Package B ONTs.
Table 1-3 Package B ONT considerations and limitations
Considerations and limitations
When using multicast on multiple Ethernet ports, all Ethernet ports must have the same VLAN ID. If the user-side VLAN IDs are all given the same VLAN ID, a common VLAN ID should result. If not, VLAN
4094 will be used
Package B ONTs are not able to sufficiently buffer enough traffic between grants to support an EIR rate of 1Gb/s over multiple GEM ports. There are only 1.256 Gb/s buffers available in the SoC chip.
The buffers are divided among the number of configured GEM ports. Reducing the number of GEM ports configured results in increased upstream buffering and higher upstream traffic rates.
Packets of less than 64 bytes are increased to 100 bytes in size with padding under the following conditions:
• in a downstream direction
• in an upstream direction only if the ONT has more than 2 Ethernet ports
Package B ONTs that use pre R04.00.10 software may not range if the distance from the LT card is less than 1km
1-10
Package C ONT considerations and limitations
Table
1-4 lists the considerations and limitations for Package C ONTs.
Table 1-4 Package C ONT considerations and limitations
Considerations and limitations
Support for up to 32 GEM ports per Ethernet UNI
Support for 7 T-CONTs including the OMCI T-CONT
Ethernet OAM (802.1 ag) is not supported
TPID overwrite is not supported
Anti-spoofing is not supported
802.1x is not supported
IGMPv3 snooping with SSM is not supported
VLAN translation is supported prior to replication for downstream IPTV multicast. The same VLAN operation must be provisioned for all Ethernet UNIs participating in IPTV multicasting
The ONT will not support sending some untagged multicast frames through one Ethernet UNI while sending other tagged multicast frames through another Ethernet UNI
(1 of 2)
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
Considerations and limitations
Double-tagged frames are not supported
Flow control is not supported. The ONT will not generate PAUSE frames for the client if there is traffic congestion
Configurable Ethernet for VLAN tag detection is not supported. Currently, only 0x8100 is supported
POTS pull-break-dial-tone (PBDT) is not supported for SIP, H.248, and G6
Call history data collection (ONTCALLHST) is not supported
G.729 and G.711 a/u are supported while G.726-32 codec is not supported
Only one global DSCP to pbit mapping table is supported
Default Ethernet flow and wildcard Ethernet flow coexisting on the same Ethernet port is not supported
Maximum of 16 service flows (VLANs) can be enabled with pbit translation
Non-supported call services:
• Direct connect
• Warm line
• Call forward status indications
• Home Intercom
• Call park
• Bridged line
• Call pickup with barge-in
• Suppressed ringing
Service classification by Ethertype is not supported
The first time an ONT is connected, the initial Ethernet UNI is enabled by default. This Ethernet UNI can be disabled by the OLT
When pbit translation is enabled, each GEM port can only translate into one pbit. Mapping downstream Pbits to different GEM ports is the only form of supported pbit translation
Static multicast is not supported
IPTV multicast over PPPoE (from the multicast port) is not supported
PM counter is partially supported
Pbit translation following DSCP to pbit mapping is not supported
Pbit translation when a UNI is set to pass through any VLAN ID (unisidevlan=4096 and networksidevlan=4096) is not supported
Packet loss occurs in 1G wirespeed. Due to the additional 4-byte routing tag, throughput is less than
1G for all packet lengths
Weighted round robin (WRR) is not accurate when configured with OMCI because the weight definition in BL device is the reverse of OMCI definition
For WRR scheduling, bandwidth is not used by a queue can not be claimed by any other queues
Up to eight extended VLAN rules per VLAN port is supported
AES key can not be changed locally on an ONT
(2 of 2)
Package G ONT considerations and limitations
Table
1-5 lists the considerations and limitations for Package G ONTs.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-11
1 — ONT and MDU overview
Table 1-5 Package G ONT considerations and limitations
Considerations and limitations
No support for per VLAN protocol downstream tagging mode
In SVLAN cross-connect tunnel mode:
• use non-overlapping pbits since the use of the same pbits on two or more VLAN ports results in a mismatch alarm
• downstream frames sent with a single tag normally sent out on the user-side as untagged, will instead be sent as priority tagged
When using CVLAN translation, or when the same queue is used for multiple pbits, the highest pbit value in the queue in the downstream direction will be selected to stomp the pbit in the packet
Simultaneous configuration of a CVLAN port and an S-Tunnel on the same UNI will only be supported if these services are provisioned with non-overlapping pbits
The same VLAN port must be used when employing both protocol-based VLAN for PPPoE and
IPoE-based VLANs
When the VLAN is translated, the pbit value must be modified and the highest pbit value is mapped to that GEM port
When more than one Ethernet port is in VLAN translation mode, or set to flexible mode with IGMP channels created, the USERSIDE VLAN IDs of those services are different. All downstream multicast packets will be tagged on the UNI port with VLAN ID of 4094
Maximum use of multicast on 1 Ethernet port at a time
For C forwarder and S+C CC forwarder, if the VLAN port uses regenerated profiles or regenerated pbits, then the downstream traffic can only flow with the derived pbits
When either tip or ring is grounded, DGNONTPOTS tip to ground and ring to ground restrictive measurements are simultaneously reported as 0 ohms
Package H ONT considerations and limitations
Table
1-6 lists the considerations and limitations for Package H ONTs.
Table 1-6 Package H ONT considerations and limitations
Considerations and limitations
Do not submerge business ONTs. The ONT cannot withstand water submersion caused by flooding.
Equipment damage will occur
The B-0404-A E1 interface supports standard 120 Ω termination via an RJ-48C. Customers that require a 75 Ω termination need an external adapter
Line loopbacks are not supported
The B-0404-A does not support VLAN translation and VLAN pass-through traffic that uses the same p-bit across the same UNI or downstream p-bit translation when services are configured in VLAN pass-through mode
1-12 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1.2
1 — ONT and MDU overview
ONT ITU-T standards
All Alcatel-Lucent ONTs are developed using the following GPON ITU-T standards:
• G.984.1(GPON Service requirements)
• G.984.2 (GPON PDM layer)
• G.984.2 (GPON PDM layer) amendment 1
• G.984.3 (GPON TC Layer)
• G.984.3 (GPON TC Layer) amendment 1 and 2
• G.984.4 (GPON OMCI)
• G.984.4 (GPON OMCI) amendments 1 and 2
ONT and MDU software architecture and protocols
provides a depiction of each level of software used to support the ONT hardware.
Figure 1-1 Software architecture levels
Service Management Applications
File storage
Database
Protocols
Embedded Linux Operating System
Low Level Device Drivers
Hardware Functional Blocks
19422
The following list provides a description of the hardware and software functions supported for all ONTs.
1 The hardware functional blocks are described in the ONT unit data sheets.
2 Low level device drivers control elements of each functional block on an ONT.
3 The embedded Linux kernel provides the operating system for the ONT.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-13
1 — ONT and MDU overview
1.3
4 Each ONT supports the following protocols:
• TCP/IP
• ICMP
• IGMP version 2 and 3
• FTP
• DHCP
• ARP
• VoIP (including SIP mode 1 and 2, H.248 (Megaco), etc.)
• PPPoE
• UDP
5 SOC-based ONTs rate-limit the number of control packets for protocols IGMP,
DHCP, and ARP to 10 control packets per second by ONT UNI port. IGMP is not rate-limited for an ONT UNI port if an IGMP channel is provisioned for the port.
6 ONTs provide a file storage database (flash or SDRAM).
7 ONTs provide service management applications including the following:
• ONT management control interface (OMCI) manager
• VoIP manager
• VDSL2 manager
• 802.1x manager
• DS1/E1 manager
• MoCA manager
• Ethernet manager
• Craft manager
• Filter manager (DOS, rate limiting, OAM, MAC, DHCP, anti-spoofing etc...)
• DHCP client
• IGMP video manager
• GPON/Port-ID, QoS, and VLAN tagging manager
• GPON manager
• Equipment manager
• Software download manager
• MLT/Diagnostics manager
GPON transmission support
The GPON transmission layer supports GEM based packets as well as the following features also described in G.984.3 (GPON TC Layer) ITU specification.
1-14 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
FEC
Forward Error Correction (FEC) is used by the GEM transport layer between the
ONTs and an P-OLT, and is based on transmitting the data in an encoded format. The encoding introduces redundancy, which allows the decoder to detect and correct the transmission errors.
Note — FEC is not supported on the following types of ONTs:
• I-020E-B
• I-020E-H
• I-220E-A
• O-421E-B
Fragmentation
Fragmentation occurs when a packet received at the ONT is larger than the maximum transmission grant size. The ONT segments the packet and sends the segments in multiple GEM frames over the GPON to the LT card at the P-OLT. The packets are then reassembled at the LT card. Fragmentation occurs between the ONT and the
P-OLT in the upstream direction.
AES
The SSH transport layer provides authentication, encryption, and integrity.
Encryption is provided by a public-private key exchange to negotiate a shared session secret between the ONT and the P-OLT: the symmetric key for AES. The connection layer provides multiplexing of different streams over the transport layer.
AES is enabled on a per-service level during service configuration at the P-OLT using TL1.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-15
1 — ONT and MDU overview
1.4
1-16
ONT activation and behavior using SLID
For the P-OLT to communicate with an ONT, the ONT must be connected to the
PON and the P-OLT must know either the serial number of the ONT, or the subscriber location ID (SLID) of the ONT.
• A serial number is hard coded into ONTs. The ONT serial number can be entered into the P-OLT using the ENT-ONT TL1 command before or after the ONT is installed at the customer site. The installer must install the ONT with the corresponding serial number at the customer site.
• The SLID is a decimal number, a hexadecimal number, or an alphanumeric string that uniquely identifies an ONT on a PON. For the P-OLT to know an ONT by a
SLID, the SLID must be entered in two places:
• at the P-OLT using the TL1 command ENT-ONT before or after the ONT is connected to the PON
• at the ONT before the ONT is connected to the PON, using one of the SLID entry methods described in the following sections. The installer can use any ONT for a customer, but the same SLID must be used. When the ONT is polled, the P-OLT and the ONT SLIDs are compared. If the SLIDs match, the serial number is retrieved from the installed ONT and registered at the P-OLT.
The following sections describe SLID entry methods supported by some
Alcatel-Lucent ONTs. The procedures for entering the SLID using these methods are described in the operations and maintenance documentation for the OLT.
SLID entry via craft terminal
The SLID can be entered with a laptop connected to the craft port on the ONT. This method is only supported on outdoor ONTs that have a craft port. A CLI interface supports this SLID entry method; see section
for more information about the CLI
interface.
SLID entry via Ethernet port
The SLID can be entered with a laptop connected to an Ethernet port on the ONT through a Telnet session or an HTTP client. This method is only supported on indoor
ONTs that have Ethernet connections. A CLI or HTTP interface supports this SLID entry method; see section
for more information about the CLI and HTTP
interfaces.
SLID entry via first POTS port
The SLID can be entered with a butt set connected to the first POTS port on an indoor or outdoor ONT supporting this SLID entry method.
SLID and LED behavior
If a currently provisioned SLID contains non-numeric digits, the ONT exits the SLID output mode. If a currently provisioned SLID contains only numeric digits, the value is displayed back to the installer using the POTS or Voice LED on the ONT or MDU.
Each SLID number is determined by counting the number of times that the LED flashes.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1.5
1 — ONT and MDU overview
If a currently provisioned SLID contains non-numeric digits, the ONT exits the SLID output mode. If a currently provisioned SLID contains only numeric digits, the value is displayed back to the installer using the POTS LED on the ONT. Each SLID number is determined by counting the number of times that the POTS LED on the
ONT flashes as follows:
• If the SLID is in decimal format:
• For the numbers 1 to 9, the flash pattern is 0.5 second of green light followed by 1 second of no light, repeated the number of times necessary to correspond to the number.
• For the number 0, the flash pattern is 0.5 second of green light followed by 1 second of no light repeated 10 times.
• There is a three second interval between digits.
• If the SLID is in hexadecimal format:
• For the numbers 1 to 9, the flash pattern is 0.5 second of green light followed by 0.5 second of no light, repeated the number of times necessary to correspond to the number.
• For the number 0, the flash pattern is 0.5 second of green light followed by 0.5 second of no light repeated 10 times.
• There is a three second interval between digits.
Note 1 — The SLID number displays more slowly in decimal format than in hexadecimal format.
Note 2 — The SLID number can be verified at any time by connecting a butt set to the first POTS port and dialing the “#” key.
ONT management at a local site
ONT interfaces support the management of an ONT at a local site, and include:
• HTTP interface
• CLI interface
• HTTP interface for Package C ONTs
• CLI interface for Package C ONTs
• butt set
The HTTP and CLI interfaces provide access to utilities that allow a field technician to:
• retrieve product information about an ONT, such as vendor name, firmware, type of ONT, and serial number
• retrieve operational information about an ONT, to monitor events such as the operational states, uptime, receive signal strength indication (RSSI), status of
LEDs, and ranging state of the ONT
• monitor a software download to an ONT
• reboot or reset an ONT to recover from connection, power, software download, and other failures
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-17
1 — ONT and MDU overview
Utilities
Retrieval of ONT product information
Retrieval of ONT states
Retrieval of ONT uptime
Retrieval of RSSI
Retrieval of status of LEDs
Retrieval of ranging state
Retrieval of software download state
OMCI and protocol tracing
Entry and clearing of SLID
• perform OMCI and protocol tracing for problem diagnosis and resolution
• enter the SLID at an ONT, to activate ONTs with their provisioning data and services using the SLID method, and to clear the SLID when an ONT is removed
Package C ONTs have a unique CLI that enable a field technician to retrieve and modify the SLID and HTTP interface for viewing the current and entering a new
SLID.
The butt set allows a field technician to enter or clear the SLID at an ONT using a
POTS port.
Table
1-7 identifies with a check mark the utilities that an ONT interface supports.
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Table 1-7 Utilities supported by ONT interfaces
HTTP interface
✓
✓
✓
✓
✓
✓
✓
CLI interface HTTP interface for
Package C
ONTs
✓
CLI interface for Package C
ONTs
Butt set
✓
✓
✓
✓
✓
✓ ✓ ✓
1-18
Access to ONT interfaces
An ONT interface is accessible through a port on the ONT.
• HTTP interfaces are accessible through an Ethernet connection on indoor ONTs with an HTTP server.
• The CLI interface is accessible through an Ethernet connection on indoor ONTs, and a serial RS-232 craft connection on outdoor ONTs.
• The CLI interface for Package C ONTs is accessible through an Ethernet connection and a serial RS-232 craft connection.
• The butt set is used through a POTS connection on an indoor or outdoor ONT.
Table
1-8 identifies the ONT interfaces, the ONTs that a specific ONT interface
supports, the field equipment that the ONT interface requires, and the ONT port on which the field equipment must be connected.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1.6
1 — ONT and MDU overview
ONT interface Supported ONTs
HTTP interface
CLI interface
HTTP interface for Package C
ONTs
CLI interface for
Package C ONTs
Indoor ONT with Ethernet connection and HTTP server
Indoor ONT with Ethernet connection
Outdoor ONT with craft connection
Indoor ONT with Ethernet connection and HTTP server
Butt set interface
ONTs with Ethernet connection
ONT with craft connection
Indoor ONT with POTS connection
Outdoor ONT with POTS connection
Table 1-8 Local ONT interfaces
Field equipment required
Computer or laptop with HTTP client
Computer or laptop with Telnet software
Computer or laptop
Field equipment connected to
First Ethernet port
First Ethernet port
Craft port
Computer or laptop with HTTP client
First Ethernet port
Computer or laptop with Telnet software
Computer or laptop
Butt set
Ethernet port
Craft port
First POTS port
ONT interface security
The HTTP and CLI interfaces are password-protected to prevent unauthorized access to utilities. In addition, each ONT has a security setting that specifies the access level of a user to the HTTP and CLI interface utilities, after the ONT is ranged. User access levels are as follows:
• read-write access, which grants a user read and write access to all utilities
• read-only access, which grants a user read-only access to the SLID, ranging state, and RSSI of the ONT
• no access, which denies a user access to all utilities
ONT configuration using a web-based interface
Some Package C ONTs support additional limited configuration using web-based
GUIs not included in section
. By using the provided GUIs, the customer can perform the following configuration and reporting tasks:
• Network (including LAN, WAN, and Wi-Fi service configuration)
• Advanced (including SNTP, DDNS, Port forwarding, and Firewall configuration)
• Maintenance (including password change, revert to factory default, reboot device, and upgrade tasks)
• Status (including the display of device info, WAN status, and PON Statistics information)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-19
1 — ONT and MDU overview
1.7
1.8
The Package C ONT that supports limited configuration using web-based GUIs is the
I-241W-P indoor ONT.
ONT physical security
Physical ONT security is provided to limit unauthorized access to remote or outdoor units. Tamper-resistant seals and bolts are used to secure the TELCO access cover to the ONT and to prevent easy access to the enclosure. Specialized security wrenches are required to open the pin-in Allen-type tamper-resistant screws. Certain models of indoor ONTs cannot be opened.
Rogue ONT defense
Fault or error conditions on a single ONT may disrupt the PON for other ONTs on the same PON. Figure
1-2 shows some possible failure conditions.
Figure 1-2 Rogue ONT failure conditions
2) serial # 123abc
X
ONT
7342
LT
2) If 2 ONTS report
identical serial #s,
both ONTS are disabled
Increasing becdown counters?
PON
ONT deactivates
X serial # 123abc
X
ONT
1) Watching timer
to ensure laser is
not stuck on or
no laser until
ONT s/w is ready
X
ONT
3) Bandwidth map
CRC failure
18997
The following conditions on a single ONT may affect other ONTs using the same
PON:
• an ONT continuously sends light up the fiber because a laser is stuck on, which may render the PON unusable
• two ONTs with the same serial number prevents correct ranging of both ONTs
• an ONT misinterprets the bandwidth map, causing the ONT to transmit for the wrong time slot allocation, disrupting the PON for another ONT that is trying to use its correctly allocated time slot
• an ONT signal is outside its timing window, affecting the start of another ONT time slot
• an ONT signal is too low or too high, causing bit rate errors or a ranging failure
1-20 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
The system is designed to automatically identify these ONT fault or error conditions using alarms, statistics, or automatic action. This tells operators of a problem or disables the ONT so a single rogue ONT cannot affect the entire PON.
Laser stuck on
ONTs use watchdog timers to stop errors that cause light to be continuously sent up the fiber. These watchdog timers are maintained by the software. When a watchdog timer fails, the hardware triggers a reset. When a reset is triggered, the laser is disabled. Before the laser retransmits, the ONT software must pass power on and self tests.
Duplicate serial numbers
An ONT is automatically disabled when:
• A ranged ONT sends a broadcast PONID within a serial number PLOAM message. This indicates the ONT may not be aware of its ranged state or that a second ONT using the same serial number is on the PON.
• An ONT sends a serial number PLOAM message that does not match its assigned
ID.
• An ONT sends a serial number PLOAM message but the ONT has not been assigned a PONID.
• A deactivate PLOAM message has been sent to the ONT three times and the ONT has not deactivated. The ONT is then sent a disable PLOAM message.
Receive and transmit errors
There are two ways to identify marginal receive problems:
1 Self correcting CRC check for the time slot; if the time slot allocation fails a CRC check, the ONU does not transmit in that time slot.
2 Increasing rate of becdown (Bit Error Rate Count Downstream) statistics.
There is one way to identify marginal transmission timing and level problems. If a marginally transmitting (due to timing or optical signal levels) ONT does range, upstream data from that ONT and possibly other ONTs on the PON will be corrupted. Increasing rates of becup (Bit Error Count Upstream) statistics are seen.
The becup counters of the marginally transmitting ONT increase the fastest. Other
ONTs may see smaller increases.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-21
1 — ONT and MDU overview
1.9
802.1x authentication
The P-OLT maintains the 802.1x authentication state by terminating the 802.1x protocol and authenticates end users using the RADIUS server. The ONT provides the filters for blocking and unblocking a local area network (LAN) port on the ONT.
After the system authenticates a port using 802.1x, the user can use DHCP or PPP.
Note — The 802.1x protocol is only applicable to iBridge mode. In iBridge mode, VLAN-tagged frames are not supported for 802.1x.
The 802.1x protocol can be enabled or disabled for each OLT system or for each
ONT user-network interface (LAN port).
Port-based authentication
There are two MAC configuration scenarios for authentication:
• When MAXMAC is 1, the first MAC address to be authenticated is learned on the bridge port for the duration of session timeout (not the FDB aging timeout). The
MAC address is learned on all VLANs configured on the bridge port. No other
MAC addresses are learned.
• When MAXMAC is greater than 1, MAC learning occurs after authentication is successful. All MAC addresses are learned dynamically and age out using the
FDB aging timer. The system responds with EAP-Success message if other users on the port try to authenticate after the port is authorized for traffic.
When the authenticated user logs out, the system performs the following actions:
• closes the port for traffic
• stops accounting for the port
• sends an identity request as multicast over the port to invite any potential users of the port for authentication
• opens the port for traffic again only after a successful authentication
• sends new identity requests only after the held period expires if the authentication fails
• sends periodic identity request messages until the port is authenticated
• does not require re-authentication
• flushes the FDB entries that correspond to the port
When the maximum MAC value on a bridge port is changed by the operator to a lower value, the system performs the following actions:
• flushes all the forward database (FDB) entries on the port
• closes the associated ONT UNI for data traffic
• sends identity request as multicast over the port in order to invite any potential users of the port for authentication
• opens the port for traffic after successful authentication
1-22 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
802.1x support assumptions
The system supports 802.1x authentication based on the following assumptions:
• Authentication is supported only on LAN ports at the ONT and not for the plain old telephone system (POTS) lines.
• Authentication is performed on an ONT UNI basis. The highest priority GPON encapsulation module (GEM) port ID that is configured on the user network interface (UNI) is used for authentication.
• There is no local authentication for 802.1x when the RADIUS server fails.
User session disconnection by system
The following three types of user disconnections are supported:
• When the RADIUS requests disconnection, the system does not send an accounting stop message. The system sends a failure message to the first authenticated user on the port and initiates the authentication of other users on the port.
• When the maximum session duration is expired. The system sends a failure message to the first authenticated user on the port and initiates other users on the port to start authentication.
• When there is a request to disable or delete a user port, the system gracefully terminates the user sessions on the port before the port is disabled or deleted. User session accounting data is sent to the RADIUS accounting servers when the session is terminated.
Re-authentication
To ensure that there is no service interruption during re-authentication, it is required re-authentication of the supplicant must occur before the session expires. The supplicant does not cause any service interruption during re-authentication. New accounting-stop or accounting-start messages are not sent due to re-authentication.
The P-OLT supports the re-authentication state. The configuration of the re-authentication function is made on a port basis and includes enabling or disabling re-authentication and setting the re-authentication period.
The RADIUS Termination Action attribute is supported. If a Termination Action is received, re-authentication is performed only at the request of the RADIUS server.
The RADIUS server overrides local configuration of re-authentication in the P-OLT.
If re-authentication is enabled on a port, the Session Timeout value returned by
RADIUS service is used as the re-authentication period. If the RADIUS server does not return a Session Timeout value, the re-authentication timer for the port that is configured by the management system is used.
If there is no response from an RADIUS server for re-authentication due to an NT card switchover, the P-OLT treats the re-authentication as a successful one for 30 min.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-23
1 — ONT and MDU overview
1.10
If re-authentication is disabled for a port, the Session Timeout value returned by
RADIUS server is used to terminate the sessions. Re-authentication initiated by the management system is not required.
During re-authentication, traffic to and from the user is not interrupted. The port forwards bidirectional traffic until re-authentication is completed. If re-authentication fails, the port is changed to unauthorized state.
An EAP Request Identity message is sent to the port when the re-authentication timer expires.
Anti-spoofing mechanism
The system supports two features to protect against spoofing:
• gratuitous ARP discard
• source address anti-spoofing
Gratuitous ARP discard
A gratuitous ARP request is an ARP packet where the sender IP address and the target IP address are the same. Attackers can use gratuitous ARP requests to corrupt the ARP cache of a router by sending out a gratuitous ARP request that claims to be the default router.
The system supports a discard mechanism that filters incoming traffic for gratuitous
ARP requests. When gratuitous ARP discard is enabled, incoming gratuitous ARP requests are discarded.
Gratuitous ARP discard is implemented on a per ONT UNI port basis using TL1. See the appropriate P-OLT TL1 documentation.
Note — Gratuitous ARP discard only applies for residential bridge
VLANs; in VLAN cross-connect mode, gratuitous ARP requests are always forwarded.
Source address anti-spoofing
Source address spoofing is an attempt to gain entry to a system by posing as a trusted source. Although the packet cannot be routed back to the initial source, source address spoofing can lead to unnecessary network congestion and to possible denial of service.
To block unauthorized traffic, the system supports an anti-spoofing mechanism that limits source address spoofing. Upstream traffic arriving at the ONT is validated for source address. Authorized packets are forwarded and non-validated packets are discarded, as shown in Figure
1-24 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
Figure 1-3 ONT packet authorization
Forward authorized packets
Authorize packets
Upstream packets
ONT
Discard unauthorized packets
Authorized source addresses
19075
Source address anti-spoofing is implemented in either static or dynamic mode.
• Static mode enables the table of authorized source addresses to be provisioned statically by an operator for one of the following anti-spoofing control types:
• MAC only
• IP-only
• MAC and IP
• Dynamic mode enables the table of authorized source addresses to be provisioned both statically by an operator and dynamically through DHCP, and supports the anti-spoofing control type IP-only.
Source address anti-spoofing filters are applied as follows:
• For IP-only anti-spoofing, packets that match a configured source address are forwarded, and non matching packets are dropped.
• For MAC and IP anti-spoofing, packets that match a configured pair of MAC source address and IP source address are forwarded, and non-matching packets are dropped.
• MAC-only anti-spoofing can be implemented in one of two modes:
• Inclusive mode forwards packets that match a configured MAC source address, and drops non matching packets.
• Exclusive mode forwards packets that do not match a configured MAC source address, and drops matching packets.
Not all anti-spoofing control types apply to all traffic. Table
anti-spoofing control types and any traffic exemptions by source address anti-spoofing mode.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-25
1 — ONT and MDU overview
Source address anti-spoofing mode
Static
Dynamic
Table 1-9 Anti-spoofing control types and traffic exemptions
Traffic exemptions Anti-spoofing control type
MAC-only anti-spoofing
IP-only anti-spoofing
MAC and IP anti-spoofing
IP-only anti-spoofing
Is applied to all data traffic
Is not applied to non-IP traffic, such as:
• PPPoE
• ARP
• EAPOL, EAP
Is not applied to DHCP packets to allow a subscriber to obtain a
DHCP lease.
The anti-spoofing control type limits the number of authorized source address entries.
When static or dynamic source address anti-spoofing is enabled, the LT card downloads the static entries provisioned for an ONT UNI port to the ONT by way of
OMCI. When a static entry is removed or anti-spoofing is disabled, the LT card notifies the ONT to remove the corresponding anti-spoofing filter(s).
When dynamic anti-spoofing is enabled, the LT card forwards the currently leased
IP addresses to the ONT by way of OMCI after an IP address is leased, or a DHCP lease expires or is released. When a UNI port has reached its maximum allowed number of IP source addresses, the LT card drops any subsequent DHCP ACKs with a leased IP address that is not in the lease table. IP source addresses that are added dynamically through DHCP survive ONT restarts, LT restarts, and NT switchovers.
See the appropriate P-OLT TL1 documentation for configuration information.
Per-service anti-spoofing
Per service dynamic or static IP anti-spoofing configuration using TL1 via the
P-OLT is supported. The dynamic IP anti-spoofing allows up to eight IP addresses to be learned. The static IP anti-spoofing allows up to eight IP addresses to be specified by the operator.
When services dynamic IP-only anti-spoofing is configured for the ONT UNI, and per service anti-spoofing is enabled for a service, packets are allowed with a combination of leased IP address and the C-VLAN ID of the service. A packet sent upstream (user to network) over the service is permitted if the incoming packet’s source IP address is that of the IP address leased for that service. In the case of static
IP addresses (configured IP addresses), the C-VLAN check is not performed for the service in the ONT UNI and hence filtering is based on static IP address.
1-26 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
1.11
ONT reset
The ONT can be rebooted or reset using the HTTP, the CLI interface or the reset button on the ONT. A reboot/reset of the ONT can be used to recover from connection, power, software download, and other failure situations. The reboot process will interrupt service for a short period of time, approximately one minute.
The reboot sequence consists of:
• hardware self check
• file system initialization
• PLOAM activation
• ranging of the ONT
• provisioning download from OLT
• activate POTS service
• activate VoIP service
ONT and MDU interface connection limitations 1.12
Table
1-10 shows the maximum connection capacity for ONTs and MDUs.
Table 1-10 ONT and MDU connection capacity
ONT type and model
I-020G-F
I-010G-P
I-020G-P
I-040G-P
I-240G-B
I-240G-P
I-240G-Q
Business ONT
B-0404-A
ONTs
I-010G-A
I-010G-B
I-011G-P
I-020E-B
I-020E-H
0
0
0
0
0
0
0
0
0
2
2
0
2
(1 of 2)
Maximum capacity
POTS 10/
100/
BASE-T
10/
100/
1000
BASE-T
—
—
—
—
2
2
—
—
—
—
—
—
—
4
1
2
—
2
1
—
1
1
4
4
4
4
RF video
(CATV)
—
—
—
—
—
1
—
—
—
—
—
—
—
MoCA
—
—
—
—
—
—
—
—
—
—
—
—
—
VDSL2 DS1/E1 Local craft
—
—
—
—
—
—
—
—
—
—
—
—
—
4
—
—
—
—
—
—
—
—
—
—
—
—
0
—
—
—
—
—
—
—
—
—
—
—
—
GPON
SC/APC
1
1
1
1
1
1
1
—
1
1
1
1
1
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-27
1 — ONT and MDU overview
ONT type and model
I-241G-P
I-241W-P
I-440G-P
MDUs
O-00160V-Q
O-00240V-P
O-00240V-Q
O-0881V-A
(2 of 2)
0
0
0
0
2
2
4
Maximum capacity
POTS 10/
100/
BASE-T
—
—
—
4
4
10/
100/
1000
BASE-T
4
1
1
0
RF video
(CATV)
MoCA
—
—
—
1
1
1
8
—
—
—
—
—
—
—
1
—
—
—
—
VDSL2
16
24
24
8
—
—
—
DS1/E1 Local craft
—
—
—
—
—
—
—
—
1
—
—
—
—
—
1
1
1
1
1
1
1
GPON
SC/APC
Table
1-11 shows the maximum number of ONTs or MDUs supported on a given
PON when all ONTs or MDUs are of the same type.
ONT
Business ONT
Indoor ONT
MDU
Table 1-11 Maximum ONT or MDU connections per PON
Maximum ONTs per PON
64
64
64
1.13
Other ONT limitations
Table
1-12 show ONTs and MDUs limitations that need to be observed.
Table 1-12 PON and ONT limitations
Limitations
Data UNIs per PON
CESUNI ports per PON
CESPW services per
PON
POTS ports per PON
VIDEO ports per ONT
(1 of 2)
Maximum number Comment
288 The total number of ENET, VDSL2, CES, and VOIP
UNIs. Create a VOIP UNI for a planned ONT when
VOIPALLOWED=YES.
128
128
—
—
384
1
—
—
1-28 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
1 — ONT and MDU overview
Limitations Maximum number
IGMP channels per PON 288
Comment
Create these channels on VLANports only on a GPON
LT.
PM threshold (TCA) counters per ONT
128 A limitation that is not readily apparent to the user.
PM threshold counter resources are allocated as
ONTs and UNIs allow for the possibility of monitoring
PM threshold crossings, even if these are not enabled by default. Depending on the line type, different numbers of TCA counter resources are allocated:
• ONT — 1
• VOIP — 1
• ENET — 1
• VDSL2 — 3
(2 of 2)
Some ONTs have limitations that are linked to their package type. Both Package A and B ONTs have specific limitations that apply only to them.
Upgrade considerations and limitations
Existing ONTs that use 7342 ISAM FTTU releases older than R04.06.xx and
R04.07.xx must be upgraded to use R04.00.10 software while assigned to a PON ID value smaller than 64. For this purpose, if split ratios larger than 1:64 are being deployed, you may choose to set aside the first PON ID as a staging point.
Service creation considerations and limitations
Port-to-port mode must be enabled when using the four-port Ethernet ONT I-x4xx-x.
When using port-to-port mode, you can only configure one Ethernet port.
OAM and statistics considerations and limitations
PM_ONTENET counters for SQE, IMTE, and CSE performance monitoring are not supported.
TC layer OAM performance monitoring is not supported on the OLT R04.00.10 therefore LOSTFRAGS and TXFRAG counters for PONONTTC are not supported on indoor ONTs.
The REPT-OPSTAT-ONTANI TL1 command which is used to determine the received optical power of the ONT will only work for RSSI-enabled ONTs.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
1-29
1 — ONT and MDU overview
1-30 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview
2.2 Part numbers for ordering 2-2
2.3 ONT and MDU to UPS or power adapter compatibility support 2-9
2.4 Fiber distribution network 2-13
2.5 ONT and customer premises environment 2-16
2.7 ONT product identification 2-20
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-1
2 — Part numbers, ordering, and deployment configuration overview
2.1
Overview
This chapter provides information about planning and ordering equipment. The
CRoHS column in the tables below indicate the CRoHS compliance status. CRoHS regulations only apply to products and subassemblies that are sold in the China market. See the ETSI environmental CRoHS guidelines for more information.
The information documented in the CRoHS column is explained as follows:
• No HS indicates that hazardous substances are not present.
• See HST indicates that the Hazardous Materials Table should be referenced, as indicated in the CRoHS guidelines mandatory regulations.
• Not for sale in PRC indicates that the equipment is not for sale in the People’s
Republic of China.
Part numbers for ordering 2.2
Table
2-1 lists the ordering information for the ONTs, MDUs, and power supplies.
Table 2-1 ONT, MDU, and power supply ordering information
Additional information Mnemonic Unit data sheet
B-0404-A business ONT
B-0404-A B-0404-A unit data sheet
Part number
3FE 61618 AA
Cable storage and mounting
Storage adapter bracket
Storage adapter bracket for
Class 1 wiring
Cable entry fitting
Cable reels
—
—
—
—
—
3EM 20293 AA
3EM 20425 AA
3EM 20425 AB
3EM 20886 AA
Stand mount —
07RZQLF0003 (Madison)
07RZQLF0003 (Tyco)
1AC006160004 (Asia Link)
QA6819JRV (ISOTEC)
CDC170 (BELDEN)
3FE 60673 AA
CRoHS
Four RJ-45 GigE ports and
RJ-48C E1/T1 ports for transmitting voice and data.
Provides storage space for 70 ft of excess fiber optic cable.
The bracket that interfaces between cable storage and the
ONT.
The bracket that interfaces between cable storage and the
ONT. It allows separate routing of power cable per Class 1 wiring standards.
An Alcatel-Lucent conduit for the cables used with the business ONT
The cable reel used to build customized cables for power and alarm connections between the UPS and the ONT.
RoHS-compliant reels are available from the listed companies.
The stand mount used to install the ONT vertically on a flat surface such as a desk.
See HST
No HS
Not for sale in PRC
Not for sale in PRC
No HS
See HST
—
Indoor ONTs
(1 of 8)
2-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview
Mnemonic
I-011G-P
I-010G-A (28 dB)
I-010G-B
I-010G-P
I-020G-P
I-040G-P
I-020E-B (28 dB)
I-020E-H (28 dB)
I-020G-F (28 dB)
I-110G-P
I-220E-A
I-241G-A
Unit data sheet
I-011G-P unit data sheet
I-010G-A unit data sheet
I-010G-B unit data sheet
Part number
3FE 52959 AY
I-010G-P,
I-020G-P, or
I-040G-P unit data sheet
3FE 52957 AA (AC/DC plug EU)
3FE 52957 AD (AC/DC plug AU)
3FE 52957 AE (AC/DC plug UK)
3FE 52957 AB (AC/DC plug EU)
3FE 52957 AF (AC/DC plug AU)
3FE 52957 AG (AC/DC plug UK)
3FE 52957 AL (AC/DC plug AU — customer-specific)
3FE 52957 AK (AC/DC plug US)
3FE 52957 AC (AC/DC plug EU)
3FE 52957 AH (AC/DC plug AU)
3FE 52957 AH (AC/DC plug AU)
3FE 28683 AB I-020E-B,
I-020E-H, and
I-020G-F unit data sheet
3FE 28683 AD
3AP 21017 DE
—
I-110G-P unit data sheet
I-220E-A unit data sheet
3FE 51912 AA (customer-specific logo)
3FE 51881 AC
3FE 29528 AA
3FE 52959 AA (AC/DC plug EU)
3FE 52959 AJ (AC/DC plug AU)
3FE 52959 AK (AC/DC plug UK)
3FE 50754 AB
3FE 50754 AE
3FE 50754 AF (customer-specific logo)
3FE 60344 AA
Additional information
The I-011G-Q ONT does not have a fiber storage tray.
An Alcatel-Lucent approved ac/dc power converter is required. Contact your
Alcatel-Lucent technical support representative.
The ONT shipped with a fiber storage tray.
A separately orderable,
Alcatel-Lucent approved ac/dc power converter is required.
A separately orderable,
Alcatel-Lucent approved ac/dc power converter is required.
ONTs shipped with fiber storage trays.
An Alcatel-Lucent approved ac/dc power converter is required. Contact your
Alcatel-Lucent technical support representative for information about ordering.
CRoHS
See HST
See HST
See HST
See HST
See HST
See HST
See HST
The I-020E-H part number 3FE
28683 AD has a maximum PON
reach of 18.6 miles (30 km) (1)
and uses SoC R2.1.
A separately orderable,
Alcatel-Lucent approved ac/dc power converter is required.
The ONT is shipped with a fiber storage tray.
An Alcatel-Lucent approved ac/dc power converter is required. Contact your
Alcatel-Lucent technical support representative for more information about ordering a separate power converter.
A separately orderable,
Alcatel-Lucent approved ac/dc power converter is required. An external 12 V dc UPS with battery backup is optional (kit number 3HG 00006 AU.
—
See HST
See HST
See HST
See HST
See HST
(2 of 8)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-3
2 — Part numbers, ordering, and deployment configuration overview
Mnemonic
I-240G-B
I-241G-B
I-240G-P
I-240G-Q
I-241G-P
I-241W-P
I-440G-P
Unit data sheet
Part number
3FE 51880 AB
3FE 51880 AA
I-240G-P,
I-240G-Q, and
I-241G-P unit data sheet
3FE 52959 AC (AC/DC plug EU)
3FE 52959 AN (AC/DC plug AU)
3FE 52959 AP (AC/DC plug UK)
3FE 52959 AX (AC/DC plug UK — customer-specific)
I-241W-P unit data sheet
I-440G-P unit data sheet
3FE 53821 AA (AC/DC plug EU)
3FE 53821 AB (AC/DC plug AU)
3FE 53821 AC (AC/DC plug UK)
3FE 52959 AD (AC/DC plug EU)
3FE 52959 AS (AC/DC plug AU)
3FE 52959 AU (AC/DC plug UK)
3FE 52958 AA (AC/DC plug EU)
3FE 52958 AG (AC/DC plug AU)
3FE 52958 AH (AC/DC plug UK)
3FE 52959 AT (AC/DC plug UK — customer-specific)
3FE 52959 AG (AC/DC plug EU)
3FE 52959 AQ (AC/DC plug AU)
3FE 52959 AR (AC/DC plug UK)
Additional information
ONTs shipped with fiber storage trays. With some customer-specific ONT configurations, a different tray
(3EM 23509 AA) can be ordered separately. Contact your
Alcatel-Lucent technical support representative for more information.
A separately orderable,
Alcatel-Lucent approved ac/dc power converter is required.
The AC, AN, and AP variants do not provide an RF video interface. The AX variant is equipped with an RF video interface that is plugged and not used.
The I-240G-P ONT does not have a fiber storage tray.
An Alcatel-Lucent approved ac/dc power converter is required. Contact your
Alcatel-Lucent technical support representative.
The I-240G-Q ONT does not have a fiber storage tray.
An Alcatel-Lucent approved ac/dc power converter is required. Contact your
Alcatel-Lucent technical support representative.
The AD, AS, and AU variants provide an RF video interface.
The I-241G-P ONT does have a fiber storage tray.
An Alcatel-Lucent approved ac/dc power converter is required. Contact your
Alcatel-Lucent technical support representative.
Wi-Fi service, version P.
ONTs shipped with fiber storage trays.
ONTs shipped with fiber storage trays.
An Alcatel-Lucent approved ac/dc power converter is required. Contact your
Alcatel-Lucent technical support representative.
CRoHS
See HST
See HST
See HST
See HST
See HST
See HST
(3 of 8)
2-4 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview
Mnemonic
Wall mount bracket
Unit data sheet
—
—
Part number
3FE 61224 AA
3FE 61677 AA
Additional information
The wall mount bracket for wall mounting I-0X0-X and I-22x-x
ONTs.
Contact your Alcatel-Lucent technical support representative for more information.
The wall mount bracket for wall mounting I-24x ONTs.
Contact your Alcatel-Lucent technical support representative for more information.
CRoHS
—
—
MDUs
O-0881V-A
VDSL2 cable
Plugs
Cable entry fitting
O-0881V-A unit data sheet
—
—
—
3FE 51905 AA
3FE 51973 AA
1AD 05394 0002
3EM 20886 AA
—
The cable equipped with a
24-pin AMP connector that provides a VDSL2 interconnection to the VDSL
MDU ONT.
Two plugs supplied with the
ONT unit but additional plugs can be ordered separately.
Three cable entry fittings are supplied with the ONT unit; additional fittings can be ordered separately.
MDU is either rack or desktop mounted.
See HST
See HST
See HST
See HST
See HST O-00160V-Q
O-00240V-P
O-00240V-Q
Phoenix
Contact IDC connector, 5 or
8 position
—
Outdoor ONTs
(4 of 8)
O-00160V-Q unit data sheet
O-00240V-P and
O-00240V-Q unit data sheet
O-00240V-P and
O-00240V-Q unit data sheet
3FE 53183 AK (AC/DC plug EU)
3FE 53183 AL (AC/DC plug AU)
3FE 53183 AM (AC/DC plug UK)
3FE 53183 AN (AC/DC plug UK)
3FE 52975 AA (AC/DC plug EU)
3FE 52975 AB (AC/DC plug AU)
3FE 52975 AC (AC/DC plug UK)
3FE 52975 AH (AC/DC plug US)
3FE 52975 AD (AC/DC plug EU)
3FE 52975 AE (AC/DC plug AU)
3FE 52975 AF (AC/DC plug UK)
3FE 52975 AG (AC/DC plug US)
1718025
MDU is either rack or desktop mounted.
See HST
MDU is either rack or desktop mounted.
See HST
Connector used when attaching wires to the battery alarm connector. Available only from
Phoenix Contact at http://www.phoenixcon.com.
—
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-5
2 — Part numbers, ordering, and deployment configuration overview
Mnemonic
O-421E-B
Unit data sheet
O-421E-B unit data sheet
Part number
3FE 50683 AJ
Additional information
The O-421E-B supports an RF return path when used with a
Gemtek dongle (3EM 23162 AA).
This device uses HPNA 3.1 technology over coaxial to establish the RF return path. A
12 V dc cable or optional Power
Injector (3EM 23161 AA) can be used to power the dongle.
CRoHS
See HST
Power equipment
Alpha outdoor
UPS
AX-12D-BBPS-
7.2-LPS
—
CyberShield CS
24 UPS 24 W,
12 V dc UPS, floating ground
CyberPower
CyberShield CS 24
UPS unit data sheet
(1) 12V/30W UPS part number:
1AF03892AF
(2) 12V/24W Home Converter part number: 1AF03877AT
(3) 7.2Ah AGM Battery, 3-year warranty: 1AF02175AF
3EM 23134 AA
Replacement information available from
UPS provider installation manual
—
—
—
1AF 17581 AA
1AB 38334 0010
1AB 38334 0008
1AB 38334 0007
1AB 38334 0009
—
ANSI municipality United
States, Canada
For ANSI Muni projects only.
Battery needs to be purchased from Alpha for outdoor deployment compliance.
The UPS for indoor ONTs functions as a power supply equipped with a backup battery. The UPS is located at a subscriber location and converts ac input (85 V ac to
264 V ac, 47 Hz to 70 Hz) to a dc output (12 V dc).
The backup battery provides up to 14 h of temporary power if power is lost. The CyberShield
CS 24 provides alarm outputs to indicate the operational status of the unit.
Battery for the 3EM 23134 AA
AC power input cords for the
3EM 23134 AA are
• North America (ANSI) (0010 variant)
• Germany, Switzerland,
Denmark (ETSI), Israel
(0008 variant)
• Australia, New Zealand
(0007 variant)
• United Kingdom, Italy,
Pakistan, Kuwait (0009 variant)
The UPS provides battery backup power may need to have the battery replaced. See the
UPS manufacturer installation manual which is provided with the UPS, for more information about replacement battery types and when to replace batteries, and the steps to safely replace a battery.
—
See HST
—
Not for sale in PRC
—
(5 of 8)
2-6 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview
Mnemonic
CyberPower 12
V 24 W UPS
CS24U12V-JP2-
SB-NC
Unit data sheet
CyberPower
CyberShield CS 24
UPS unit data sheet
CyberPower 12
V 24 W UPS
CS24U12V-xx3
CyberPower
CyberShield CS 24
UPS unit data sheet
Delta 12 V
32 W UPS
GES320W12V00
81
(DUPS1232A)
Delta DUPS-1232A
UPS unit data sheet
Delta
DUPS-1215
15 W/12 V
4.5Ah UPS
Emerson 24 W ac/dc
AD2412N3L-40
1
(6 of 8)
Delta DUPS-1215
UPS unit data sheet
Emerson 24 W
AC/DC switching power adapter unit data sheet
Part number
(1) 12 V/24 W UPS part number:
3EM23264AA
(2) Japan 2-prong AC cord =
1AB383340006
(3) ONT to UPS cable =
3EM18276AD
(1) 12 V/24 W UPS w/battery w/AC-cord part number:
1AF03877XX where XX is the regional qualification code:
• BR — ANSI
• BZ — ETSI (Germany,
Austria)
• CB — Australia, New
Zealand
• CD — United Kingdom,
Pakistan, Kuwait
(2) ONT to UPS cable =
3EM18276AD
(1) 12 V/32 W UPS part number:
3EM23134AA (Once the order is placed, SCN can select this unit or the CS24U12V3-SB-NC for the shipping variant)
(2) AC power cord,
1AB38334xxxx:
• 0007 — Australia, New
Zealand
• 0008 — Europe
• 0009 — United Kingdom,
Ireland
• 0010 — ANSI
(3) ONT to UPS cable =
3EM18276AD
3FE52412AA (UPS to ONT cable included)
1AB 38334 0070 (AC/DC plug AU,
NZ, China)
1AB 38334 0008 (AC/DC plug EU
CEE 7/7 6 ft (1.83 m)]
1AB 38334 0009 (AC/DC plug UK,
Ireland [BS1363 6 ft (1.83 m)]
1AB 38334 0010 (AC/DC plug
ANSI [NEMA 5-15P, 8 ft (2.44 m)]
1AF 01226 AS
Additional information
Japan
Battery not included with UPS.
Compliant battery models:
• BB Battery BP7.2-12
• GS Battery PE 12V7.2 (ANSI
ALU part number
1AF17581AA)
RBOC
ANSI municipality United
States, Canada
Common European Union countries
It is replaced by 3EM23134AAAA
UPS above with an ALU battery part number of 1AF17581AA for a 7.2Ahr battery.
RBOC
ANSI municipality United
States, Canada
Battery not included with UPS.
Compliant battery models:
• BB Battery BP7.2-12
• Vision CP1270A
• CSB GP1272
• GS Battery PE12V7.2 (ANSI
ALU part number
1AF17581AA)
• Ritar RT1270
Ferrites are not required.
Power adaptor
Power adapter with Molex connector
CRoHS
—
—
—
See HST
See HST
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-7
2 — Part numbers, ordering, and deployment configuration overview
Mnemonic
Power cables for Emerson
Power input cords for
Emerson
Emerson 16 W ac/dc switching power adapter
Emerson 12 W ac/dc switching power supply
Leader
Electronics
12 W ac/dc switching power adapter
—
Emerson 24 W,
12 V ac/dc switching power adapter
—
Unit data sheet
—
Emerson 16 W
AC/DC switching power adapter unit data sheet
Emerson 24 W,
12 V ac/dc switching power supply
Emerson 24 W
AC/DC switching power adapter unit data sheet
Emerson 12 W
AC/DC switching power supply unit data sheet
Leader Electronics
12W and 18W ac/dc switching power supply unit data sheet
—
Part number
DA12-120US-401 (1AF 17075 AA)
DA12-120EU-401 (1AF 17075 AB)
DA12-120UK-401 (1AF 17075 AC)
DA12-120AU-401 (1AF 17075 AD)
1AB 07676 0010
1AB 07676 0071
1AB 07676 0073
1AB 07676 0010
1AB 07676 0009
1AB 07676 0071
1AB 07676 0072
1AB 07676 0073
1AF 17075 AA
1AF 17075 AB
1AF 17075 AC
1AF 17075 AD
Additional information
Specialized output power cables with Molex connectors:
• AA for USA
• AB for Europe
• AC for UK, Ireland
• AD for Australia
C13 IEC320 to plug ac power cords for the power adapter:
• UK, Ireland, and Middle East
• Europe
• USA
Power adaptor
CRoHS
Not for sale in PRC
Not for sale in PRC
3FE 61585 AA (AC/DC plug ANSI)
3FE 61585 AB (AC/DC plug UK,
Ireland)
3FE 61585 AC (AC/DC plug EU)
3FE 62984 AA
No HS
1AB 07676 0010 (AC/DC plug UK)
1AB 07676 0071 (AC/DC plug EU)
1AF 01226 AS
Power brick, 3-pin IEC320 AC input receptacle, standard coax barrel DC connector
Power adaptor
No HS
No HS
No HS Power adapter and power supply with a Molex connector
C13 IEC320 to plug ac power input cords for the switching power supply are:
• United Kingdom, Ireland,
Middle East (0010)
• Australia, New Zealand,
China (0009)
• Europe (0071)
• United Kingdom, South
Africa, Middle East (0072)
• United States, Canada
(ANSI) (0073)
Power supply with a Molex connector for:
• ANSI (AA variant)
• Europe (AB variant)
• United Kingdom (AC variant)
• Australia, China, Korea (AD variant)
Leader Electronics 12 W, 12 V dc power adapter(MU12-2120100-C5).
Contact your Alcatel-Lucent technical support representative for more information.
No HS
—
No HS
(7 of 8)
2-8 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview
Mnemonic
Leader
Electronics
18 W ac/dc switching power adapter
Li Tone 12 V 24
W power adapter
Unit data sheet
Leader Electronics
12W and 18W ac/dc switching power supply unit data sheet
Li Tone Electronics
AC/DC switching power adapter unit data sheet
Part number
—
3EM 23308 AA
Additional information
Leader Electronics 18 W, 12 V dc power adapter(MU18-2120150-C5).
Contact your Alcatel-Lucent technical support representative for more information.
Japan
Li Tone Electronics 24 W, 12 V dc power adapter
(LTE24E-S2-320A).
Contact your Alcatel-Lucent technical support representative for recommended plug type information. This product is available from the manufacturer. The Li Tone manufacturer part number is
P00-1711-0024-052.
CRoHS
No HS
No HS
(8 of 8)
Note
(1) The maximum reach capacity supported by the P-OLT system is typically either 18.6 miles (30 km) for GLT2-x cards or
37.3 miles (60 km) for GLT4-x cards.
2.3
ONT and MDU to UPS or power adapter compatibility support
Each ONT or MDU requires either a power adaptor, direct power feed, or UPS. See
Table
2-1 for more information, including descriptions of the power adaptor and
UPS models, the ONT and MDU part numbers, and the cabling part numbers.
Caution — Use only Alcatel-Lucent tested and approved ONT and
UPS combinations. If you do not know whether a specific ONT model interoperates with a specific UPS or power adapter model, contact your Alcatel-Lucent technical support representative for more information.
Compliance and compatibility testing by compliance laboratories and by the vendors continues between software releases. The following information may not be the most up-to-date information. Contact your
Alcatel-Lucent technical support representative for more information.
ONT and MDU to UPS or power adapter mapping table
lists ONT and MDU to UPS or power adapter support mapping, including the specifications and standards tested to.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-9
2 — Part numbers, ordering, and deployment configuration overview
Table 2-2 ONT and MDU to UPS or power adapter compatibility support
ONT type (orderable part number)
Power/UPS model Power UPS and cabling part number information
Customer category or country compliance tested
Notes
B-0404 (3FE61618AA) GPON indoor business ONT
Emerson 24 W ac/dc switching power adaptor with Molex power DC cable
Part number: 1AF01226ASAA
AC power cord, 1AB07676xxxx, where xxxx is:
• 0010 — United Kingdom,
Ireland, and Middle East
• 0009 —Australia, New Zealand,
China
• 0071 — Europe
• 0072 — United Kingdom, South
Africa, and Middle East
• 0073 — ANSI
ANSI municipality United
States, Canada
Common European Union countries
Specialized output power connectors:
• USA
• Europe
• United Kingdom or
Ireland
• Australia
Emerson 12 V/24 W ac/dc power brick (adaptor),
3-pin IEC320 AC input receptacle, Molex DC connector
Delta DUPS-1215 4.5
Ahr
UPS part number: 3FE52412AA
(UPS to ONT cable included)
AC power cord, 1AB38334xxxx, where xxxx is:
• 0008 — Europe
• 0009 — United Kingdom,
Ireland
• 0010 — ANSI
ANSI municipality United
States, Canada
Common European Union countries
China/Australia/New
Zealand.
12 V/15 W 4.5 Ah UPS without battery. Compliant battery models:
• BB Battery BP4.5-12
• GS Battery PE12V4.5
(ANSI ALU part number
1AF17655AA)
• Ritar RI1245
• Vision CP1245H
I-010G-A (3FE51912Ax), I-020G-F (3FE29528Ax), I-020E-B, I-020E-H (3FE28683Ax) GPON data-only ONTs
ANSI municipality United
States, Canada
Common European Union countries
Emerson 12 V/16 W ac/dc power adapter wall wart,
2-prong AC plug
Emerson 16 W 12V switching power adapter
DA16-120xx-L (xx:
US, UK or EU)
3FE61585AA: ANSI
3FE61585AB: United Kingdom
3FE61585AC: Europe
I-241G-A (3FE60344AA) GPON Multifunction indoor ONTs
Emerson 24 W ac/dc switching power adaptor with Molex power DC cable
Part number: 1AF01226ASAA
AC power cord, 1AB07676xxxx, where xxxx is:
• 0010 — United Kingdom,
Ireland, and Middle East
• 0009 —Australia, New Zealand,
China
• 0071 — Europe
• 0072 — United Kingdom, South
Africa, and Middle East
• 0073 — ANSI
ANSI municipality United
States, Canada
Common European Union countries
Specialized output power connectors:
• USA
• Europe
• United Kingdom or
Ireland
• Australia
Emerson 12 V/24 W ac/dc power brick (adaptor),
3-pin IEC320 AC input receptacle, Molex DC connector
I-010G-B (3FE51881Ax) GPON data-only ONTs
Emerson 12 W ac/dc switching power adapter with Molex
DC cable
(1) Part number:
• 1AF17075AA — ANSI
• 1AF17075AB — Europe
• 1AF17075AC — United Kingdom
• 1AF17075AD — Australia,
China, Korea
ANSI municipality United
States, Canada
Common European Union countries
China, Australia, New
Zealand
Emerson 12 V/12 W ac/dc power adapter with Molex connector
(1 of 4)
2-10 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview
ONT type (orderable part number)
Power/UPS model Power UPS and cabling part number information
Delta DUPS-1215 4.5
Ahr
UPS part number: 3FE52412AA
(UPS to ONT cable included)
AC power cord, 1AB38334xxxx, where xxxx is:
• 0008 — Europe
• 0009 — United Kingdom,
Ireland
• 0010 — ANSI
Customer category or country compliance tested for (1)
ANSI municipality United
States, Canada
Common European Union countries
China/Australia/New
Zealand.
Notes
12 V/15 W 4.5 Ah UPS without battery. Compliant battery models:
• BB Battery BP4.5-12
• GS Battery PE12V4.5
(ANSI ALU part number
1AF17655AA)
• Ritar RI1245
• Vision CP1245H
I-220E-A (3FE50754Ax) GPON GSFU-B indoor ONTs
Emerson 24 W switching power adapter, AD2412N3L
1) Part number: 3FE62984AA
(2) AC power cord, 1AB07676xxxx:
• 0010 — United Kingdom
• 0071 — Europe
I-241G-B (3FE51880Ax) GPON multifunction indoor ONT
Emerson 24 W ac/dc switching power adaptor with Molex power DC cable
Part number: 1AF01226ASAA
AC power cord, 1AB07676xxxx, where xxxx is:
• 0010 — United Kingdom,
Ireland, and Middle East
• 0009 —Australia, New Zealand,
China
• 0071 — Europe
• 0072 — United Kingdom, South
Africa, and Middle East
• 0073 — ANSI
Delta DUPS-1215 4.5
Ahr
UPS part number: 3FE52412AA
(UPS to ONT cable included)
AC power cord, 1AB38334xxxx, where xxxx is:
• 0008 — Europe
• 0009 — United Kingdom,
Ireland
• 0010 — ANSI
Common European Union countries
Brazil
ANSI municipality United
States, Canada
Common European Union countries
Specialized output power connectors:
• USA
• Europe
• United Kingdom or
Ireland
• Australia
ANSI municipality United
States, Canada
Common European Union countries
China/Australia/New
Zealand.
Emerson 12 V/24 W ac/dc power brick, 3-pin IEC320
AC input receptacle, standard coax barrel DC connector
Emerson 12 V/24 W ac/dc power brick (adaptor),
3-pin IEC320 AC input receptacle, Molex DC connector
12 V/15 W 4.5 Ah UPS without battery. Compliant battery models:
• BB Battery BP4.5-12
• GS Battery PE12V4.5
(ANSI ALU part number
1AF17655AA)
• Ritar RI1245
• Vision CP1245H
O-00160V-Q and O-00240V-Q (3FE53183Ax, 3FE52975Ax) GPON MDUs
Phoenix Contact IDC connector
Connector used when attaching wires to the battery alarm connector:
• 5 position connector, 1718025
• 8 position connector, 1718025
O-0881V-A (3FE 51905 AA) GPON VDSL MDU ONT
United Kingdom
Europe
Australia
Direct AC power feed AC power cord, part number
1AB07676xxxx:
• 0071 — Europe
• 0073 — ANSI
ANSI municipality United
States, Canada
Common European Union countries
(2 of 4)
Connectors are only available from Phoenix
Contact at: http:// www.phoenixcon.com
—
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-11
2 — Part numbers, ordering, and deployment configuration overview
ONT type (orderable part number)
Power/UPS model Power UPS and cabling part number information
Customer category or country compliance tested for (1)
Notes
I-010G-P, I-020G-P, I-040G-P, I-011G-P, I-240G-P, I-241G-P, I-440G-P, I-240G-Q, and I-241W-P, (3FE52957Ax,
3FE52959Ax, 3FE53821Ax, 3FE52958Ax) GPON indoor ONTs
Leader Electronics ac/dc switching power supply
(1) 12 W/12 V power supply part number —
(2) 18 W/12 V power supply part number —
Contact your Alcatel-Lucent technical support representative for information about ONT/power supply compatibility.
Contact your Alcatel-Lucent technical support representative for compliance information.
Leader Electronics: 12
W/12 V ac/dc power supply with power cord (Model number: MU12-2120100-C5)
18 W/12 V ac/dc power supply with power cord
(Model number:
MU18-2120150-C5)
O-421E-B (3FE50683AJ) GPON GSFU-B outdoor ONT
CyberPower 12 V/24
W UPS
CS24U12V3-SB-NC
(1) 12 V/24 W UPS part number:
3EM23134AA. (Once the order is placed, SCN can select this unit or the DUPS1232A for the shipping variant)
(2) AC power cord, 1AB38334xxxx:
• 0007 — Australia, New Zealand
• 0008 — Europe
• 0009 — United Kingdom,
Ireland
• 0010 — ANSI
RBOC
ANSI municipality United
States, Canada
Common European Union countries
Battery not included with
UPS. Compliant battery models:
• BB Battery BP7.2-12
• GS Battery PE 12V7.2
(ANSI ALU part number
1AF17581AA)
Delta 12 V 32 W UPS
GES320W12V0081
(DUPS1232A)
(3) ONT to UPS cable =
3EM18276AD
(1) 12 V/32 W UPS part number:
3EM23134AA (Once the order is placed, SCN can select this unit or the CS24U12V3-SB-NC for the shipping variant)
(2) AC power cord, 1AB38334xxxx:
• 0007 — Australia, New Zealand
• 0008 — Europe
• 0009 — United Kingdom,
Ireland
• 0010 — ANSI
RBOC
ANSI municipality United
States, Canada
When integrated with the outdoor HPNA 3.1 dongle in
ANSI market - ferrites shipped with the HPNA 3.1 dongle are required on both
Ethernet cables. Otherwise, ferrites are not required.
Battery not included with
UPS. Compliant battery models:
• BB Battery BP7.2-12
• Vision CP1270A
• CSB GP1272
• GS Battery PE12V7.2
(ANSI ALU part number
1AF17581AA)
• Ritar RT1270
Ferrites are not required.
CyberPower 12 V 24
W UPS
CS24U12V-JP2-SB-NC
Li Tone 12 V 24 W power adapter
LTE24E-S2-3
(3) ONT to UPS cable =
3EM18276AD
(1) 12 V/24 W UPS part number:
3EM23264AA
(2) Japan 2-prong AC cord =
1AB383340006
(3) ONT to UPS cable =
3EM18276AD
(1) 24 W power adapter part number: 3EM23308AA
(2) Japan 2-prong AC cord =
1AB383340006
Japan
Japan
Battery not included with
UPS. Compliant battery models:
• BB Battery BP7.2-12
• GS Battery PE 12V7.2
(ANSI ALU part number
1AF17581AA)
Li Tone 12V/24W ac/dc power adapter. Order directly from supplier in
Japan.
(3 of 4)
2-12 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview
ONT type (orderable part number)
Power/UPS model Power UPS and cabling part number information
CyberPower 12 V 24
W UPS
CS24U12V-xx3
Alpha outdoor UPS
AX-12D-BBPS-7.2-LPS
(1) 12 V/24 W UPS w/battery w/AC-cord part number:
1AF03877XX where XX is the regional qualification code:
• BR — ANSI
• BZ — ETSI (Germany, Austria)
• CB — Australia, New Zealand
• CD — United Kingdom,
Pakistan, Kuwait
(2) ONT to UPS cable =
3EM18276AD
(1) 12V/30W UPS part number:
1AF03892AF
(2) 12V/24W Home Converter part number: 1AF03877AT
(3) 7.2Ah AGM Battery, 3-year warranty: 1AF02175AF
Customer category or country compliance tested for (1)
RBOC
ANSI municipality United
States, Canada
Common European Union countries
ANSI municipality United
States, Canada
Notes
It is replaced by
3EM23134AAAA UPS above with an ALU battery part number of 1AF17581AA for a 7.2Ahr battery.
For ANSI Muni projects only.
Battery needs to be purchased from Alpha for outdoor deployment compliance.
(4 of 4)
Notes
(1) The list of detailed tests (for example, GR-1089i3 (ESD, EFT, RDE, CDE, RDI, and CDI), GR-1089i4 (LightningAC) and marks
(for example, FCC Class B, UL, CE Mark Class B, and K.21) are available from your Alcatel-Lucent technical support representative.
(2) The power supply is available only part of a kit that includes an ONT. Contact your Alcatel-Lucent technical support representative for ordering information.
2.4
Fiber distribution network
The GPON can carry multiple applications, including voice, data, and video over a
single fiber. Figure 2-1 shows a fiber distribution network using a single GPON
connection.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-13
2 — Part numbers, ordering, and deployment configuration overview
Figure 2-1 Fiber distribution network
Network Central office or remote terminal
Fiber distribution
Passive outside plan
ONTs End user
Optical link length 1
RF Video provider network
Optional RF overlay
V-OLT/EDFA
1,550 nm
Ethernet
IPTV
WDM
1,490 nm
1,550 nm 2.4 Gb/s
1,310 nm 1.2 Gb/s
Internet
Edge switch router P-OLT
PSTN
Voice gateway
EMS/NMS
Class 5 switch
Softswitch
1 The maximum optical link length depends on the specific equipment and deployment conditions
MDU
19684
Line rate supported
Systems support standard-based GPON line rates of 2.488 Gb/s downstream and
1.244 Gb/s upstream between the packet optical line termination (P-OLT) units and optical network terminals (ONTs) based on the ITU-T G.984 protocol. The optical budget of the GPON connection is typically 28 dB.
Typical optical fiber outside plant architecture
The outside plant consists of optical fiber cables, splicing enclosures, fiber distribution cabinets or enclosures, and drop boxes. The outside plant can be implemented using different architectures. The specific architecture can greatly affect the cost of deployment.
2-14 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview
The key factors that significantly influence the cost of the architecture include:
• plant type, such as aerial or buried
• home density
• splitter location
• expected penetration rates
A typical system uses two levels of distribution and splitting. A primary flexibility point provides rough granularity for splitting the fiber, followed by a final drop or secondary flexibility point where the final split and drops to the ONTs at the premises are implemented. This basic architecture is cost-effective while also
retaining flexibility for the future. Figure 2-2
shows a typical outside plant arrangement.
Figure 2-2 Typical outside plant arrangement
Central office
OLT
36> fiber cable
(feeder)
FTP
Legend:
OLT
S
Optical Line Termination
Splice Case
S S
PON distribution cables
S
Splitter cabinet
32> fiber cables
(PON distribution)
S
Distribution cabinet
Fiber
Customer premises
ONT
21218
Distance and performance considerations
System performance varies in proportion to the amount of data that is transmitted to and from the subscriber location.
The system is designed to support a long reach from the CO to the subscriber location. The maximum reach capacity is typically 18.6 mi (30 km) for GPON LT cards. The optical link budget is defined by both loss and bandwidth characteristics.
The loss characteristic is determined by the difference between the optical transmitter and optical receiver for each direction, and is typically 28 dB. The bandwidth characteristic is determined by the maximum link distance parameter of each OLT and ONT transmitter specification, and is limited by the lower of the upstream and downstream values.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-15
2 — Part numbers, ordering, and deployment configuration overview
2.5
Splitters and unused ports
It is an industry best practice for fiber distribution networks to use APC-based connections or spliced connections to avoid any potential network problems.
Alcatel-Lucent recommends that the unused ports of splitters should be terminated on an APC-based connector.
ONT and customer premises environment
A large proportion of the physical layer connectivity problems are caused by poor installation practices and connectivity issues at the drop or inside the customer premises, because of internal wiring issues. Internal customer premises issues are outside of the scope of the ONT user documentation.
Space
Planners should determine the space requirement based on the footprint of the ONT and the UPS, and ensure that there is sufficient space at the installation site.
Alarms
Determine the alarm termination requirements. Find out the total number of alarms, and the number and types of connections required.
Power and ground cable
Examine the power and ground requirements. Collect information about the following:
• number of connections
• run lengths and required wire gauge
• termination requirements, such as lugs
• safety guidelines
Fiber drop
A significant proportion of deployment costs is linked to the drop installation and service activation. A fiber drop involves the interconnection between the drop terminal and building to be served. In a PON, the drops can serve a MDU, BONT, or
SFU.
Fiber drop cable termination is straightforward for outside installation at the customer premises. Most of the labor involves running power from inside the premises to the outside, and ensuring that the ONT is installed and grounded correctly. A large number of customer service issues are caused by incorrect installation, grounding, or cabling.
Fiber drops are more complicated for an MDU than BONTs and SFUs. MDUs may require multiple fibers in the drop cable to serve multiple ONTs or splitters in the
shows MDU cabling considerations.
2-16 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
TV
PC
TV
PC
TV
PC
Fiber patch panel
2 — Part numbers, ordering, and deployment configuration overview
Figure 2-3 MDU cabling
ONT
Riser
Indoor ONT
Fiber cabling VDSL modem
Riser
MDU ONT
Coax, CAT
PC
TV
PC
TV
PC
TV
PC
TV
TV
PC
TV
PC
TV
PC
MDU
ONT
PC
TV
PC
TV
PC
TV
PC
TV
Drop terminal
19440
MDU installation planning considerations include:
• number of units served
• cable and conduit accessibility
• ownership of cable
• customer take-up rate
Other planning considerations:
• Running cable in older buildings can be more complicated.
• Running fiber to each unit in an MDU can be a better option when the existing cable is not owned by the service provider.
• When there is no access to the existing cable in an MDU, you can use existing coaxial or Cat5e, or better wiring.
Note 1 — Ensure that Cat5e or higher wiring is used.
Note 2 — Alcatel-Lucent recommends that in the fiber distribution network, APC-based or spliced connections, are used to avoid potential problems. In particular, splitters should be configured so that unused ports are terminated on APC-based connectors.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-17
2 — Part numbers, ordering, and deployment configuration overview
Customer premises
Successful customer installations increase customer satisfaction and reduce customer churn.
After the physical installation of the ONT and UPS, installers may be responsible for:
• running appropriately sized Cat5e or Cat3 (for voice) cabling from the ONT to outlets inside the premises
• connecting existing coaxial or Cat5e or Cat3 (for voice) cabling to support voice and RF cable services
• activating and testing voice, video, and data services
shows a cabling comparison for an SFU and an MDU.
Figure 2-4 SFU and MDU cabling comparison
MDU
ONT
Riser
SFU
TV
PC
TV
PC
TV
PC
PC
TV
ONT
PC
TV
PC
TV
PC
TV
PC
TV
Drop terminal
19439
shows a cabling comparison for SFUs with and without MoCA interfaces.
2-18 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview
Figure 2-5 SFU cabling with and without MoCA
SFU customer premise SFU customer premise w/MOCA
2.6
PC
TV
Coax
CAT
IP video
PC
TV
CAT
IP video
UPS
CAT
Coax
DC power
ONT
PC
TV
MOCA
PC
TV
CAT
MOCA
UPS
MOCA
DC power
CAT
ONT
New cabling
19441
Switching existing services from a service provider can be a challenge. For example, an existing copper network interface device may be many feet away from the ONT, while the coaxial splitter may be at the opposite end of the premises. In this case, some of the options are:
• Install the ONT on top of the existing network interface device and use the ONT as the new network interface device.
• Run copper and coaxial jumpers from the ONT to the network interface device and the RF splitter.
New housing and MDU developments provide an opportunity to optimize the wiring design to support the offered services. The options include:
• specifying a central wiring and cabling closet or box
• installing the ONT indoors and running fiber directly to the ONT from the outside
Planning maintenance
This section provides information about planning ONT maintenance.
Monitoring
The system provides maintenance tools. The 5520 AMS can be used to monitor alarms and performance. In addition, TL1 and CLI commands can be used at the craft terminal at the OLT or the ONT/MDU (if supported) to perform monitoring tasks.
Monitoring alarms and performance provide some troubleshooting, but do not provide the granularity needed for fault isolation.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-19
2 — Part numbers, ordering, and deployment configuration overview
2.7
2-20
The system supports verification and query functions for each service provided from end to end. These functions include reporting of the required system or board status fields to help isolate problems and identify the source of the problems. The functions require sufficient monitor points in the system to partition the system to effectively troubleshoot system-level problems.
Requirement for spares
Spare ONTs should be ordered to support normal maintenance activities associated with the system. ONTs do not have field replaceable parts except battery supplies for
UPSs. Replacement of the ONT is the recommended maintenance activity. ONTs removed should be reconditioned according to local practice, including all recommended actions by Alcatel-Lucent.
Training
Training is available at all levels for the operation, maintenance, and administration of the system. Contact your account representative to obtain the current version of the customer training catalog.
Documentation
Alcatel-Lucent provides a comprehensive set of documents to facilitate the installation, administration, operation, installation, and replacement of ONT equipment. See the appropriate ONT Customer Release Notes or OLT Customer
Release Notes for the user documentation releases and part numbers.
ONT product identification
In a product series, each ONT or MDU is identified by a designation that defines its interface characteristics, such as the number of voice, data, and video ports.
Table
2-3 describes the naming designation for ONTs.
Table 2-3 Naming designation for ONTs
Position in mnemonic
Beginning character
Description
The series that the product belongs to
First digit after the dash The number of POTS interfaces
Second digit after the dash The number of data interfaces
The number of video interfaces Third digit after the dash
Character after the third digit
The type of data service supported. The codes for the supported types are:
• E for 10/100BASE-T Ethernet
• G for 10/100/1000Base-T Ethernet
• H for HPNA (IP over coaxial cable)
• M for MoCA and 10/100/1000Base-T Ethernet
• V for VDSL
• W for Wi-Fi service
(1 of 2)
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
2 — Part numbers, ordering, and deployment configuration overview
Position in mnemonic
Ending character
(2 of 2)
Description
The variant
For example, I-241W-P identifies the following information:
• I – indoor ONT
• 2 –two POTS interfaces
• 4 –four data interfaces
• 1 –one RF video interface
• W –Wi-Fi service
• P –variant
Table
2-4 provides the designation for MDUs.
Table 2-4 Naming designation for MDUs
Position in mnemonic
Beginning character
Description
The series that the product belongs to
First digit after the dash The number of POTS interfaces
Second digit after the dash The number of data interfaces
The number of VDSL interfaces Third and fourth digit after the dash
Fifth digit after the dash The number of RF interfaces
Character after the last digit
Ending character
The type of data service supported. The codes for the supported types are:
• E for 10/100BASE-T Ethernet
• G for 10/100/1000Base-T Ethernet
• V for VDSL
• M for MoCA and 10/100/1000Base-T Ethernet
The variant
For example, O-0881V-A identifies the following information:
• O – MDU
• 0 –no POTS interfaces
• 8 –eight data interfaces
• 8 –eight VDSL interfaces
• 1 –one RF video interface
• V –VDSL
• A –variant
Table
2-5 provides the designation for the business ONTs.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
2-21
2 — Part numbers, ordering, and deployment configuration overview
Table 2-5 Naming designation for business ONTs
Position in mnemonic
Beginning character
Description
The series that the product belongs to
First digit after the dash The number of POTS interfaces
Second digit after the dash The number of data interfaces
Third digit after the dash The number of video interfaces
Fourth digit after the dash The number of DS1/E1 interfaces
Ending character The variant
For example, B-0404-A identifies the following information:
• B –business ONT
• 0 –no POTS interface
• 4 –four data interfaces
• 0 –no RF video interface
• 4 –four DS1/E1 interfaces
• A –variant
2-22 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3 — ONT and MDU general and interface technical specifications
3.2 System and service capacity specifications 3-2
3.3 Ethernet interface specifications 3-4
3.4 POTS interface specifications 3-6
3.5 VDSL2 interface specifications 3-8
3.6 DS1/E1 interface specifications 3-9
3.7 RF video interface specifications for video overlay 3-12
3.8 SWRD interface specifications 3-18
3.9 MoCA interface specifications 3-19
3.11 Wi-Fi specifications 3-21
3.12 Ranging, discovery, and activation of ONTs 3-22
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-1
3 — ONT and MDU general and interface technical specifications
3.1
Overview
This chapter provides information about ONT and MDU technical specifications.
System and service capacity specifications 3.2
This section provides the ONT system and service capacity specifications. Service descriptions, such as VoIP and flex services, are provided in the appropriate OLT
Product Information Manual.
P-OLT performance and distance
The P-OLT provides performance and distance capacity of 2.488 Gb/s downstream and 1.244 Gb/s upstream, within a 18.6 mile (30 km) span with GLT2-x cards and within 37.3 miles (60 km) span with the GLT4-A and GLT4-D cards. The PON reach available depends on the optical budget supported by the LT card used, the PON reach specified based on network deployments, and the loss of optical fiber, connectors, and splitters, and so on. Extended PON deployment allows you to configure each PON to provide a 20 km, 34 km, and a 40 km differential window for ranging and ONT operation.
The optical link budget is defined by both loss and bandwidth characteristics. The loss characteristic is the difference between the optical transmitter and optical receiver for each direction, and is typically 28 dB. The bandwidth characteristic is the maximum link distance parameter of each OLT and ONT transmitter specification, and is limited by the smaller of the upstream and downstream values.
PON capacity
The number of ONTs on the PON affects the bandwidth available to each subscriber.
Table
3-1 lists the capacity of various components on the PON. Individual capacity
per device is listed in the data sheet for the device.
Table 3-1 Capacity for PON system elements
Notes Capacity
PON
Maximum number of IGMP channels per PON
Maximum number of data UNI ports per PON (total of all UNI types)
Maximum number of CESUNI UNI ports per PON
Maximum number of CES PW UNI ports per PON
Maximum number of POTS ports per
PON
(1 of 2)
Maximum
288
288
128
128
384
Only created on VLAN ports.
This is the total of all CES (CESUNUI and CESPW UNI), ENET, VoIP, and VDSL2 UNIs.
VoIP UNIs are created automatically when the ONT is planned with the VOIPALLOWED parameter set to enabled (YES in TL1).
—
3-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3 — ONT and MDU general and interface technical specifications
Capacity
ONT
Maximum number of video ports per
ONT
(2 of 2)
Maximum
1
Notes
—
GEM and T-CONT capacity
Table
3-2 lists the capacity of various system components for GEM ports and
T-CONTs. Individual capacity per device is listed in the data sheet for the device.
Table 3-2 Capacity for GEM ports and T-CONTs per package and release
Maximum Notes ONT or MDU
Package A ONTs
GEM ports per indoor or outdoor ONT
All
T-CONTs per indoor or outdoor ONT
Package B ONTs
GEM ports per indoor or outdoor ONT
All
All
T-CONTs per indoor or outdoor ONT
Package C ONTs
GEM ports per indoor or outdoor ONT
All
R04.06.40 to R04.06.42
T-CONTs per indoor or outdoor ONT
R04.06.3x, R04.06.43, R04.07.40,
R04.07.45
R04.06.45x, R04.00.4x, R04.02.0x,
R04.02.40x, R04.02.41x
R04.02.42x
R04.06.40 to R04.06.42
R04.06.3x, R04.06.43, R04.07.40,
R04.07.45
R04.06.45x, R04.00.4x, R04.02.0x,
R04.02.40x, R04.02.41x
R04.02.42x
Package D ONTs
GEM ports per indoor or outdoor ONT
R04.02.42x
20
21
30
31
10
30
6
6
15
30
30
31
30
22 are present: 20 are available, 2 are reserved for OMCI and debugging
22 are present: 21 are available, 1 is reserved for OMCI
32 are present: 30 are available, 2 are reserved for multicast and debugging
32 are present: 31 are available, 1 is reserved for OMCI
12 are present: 10 are available, 2 are reserved for multicast and debugging
32 are present: 30 are available, 2 are reserved for multicast and debugging
7 are present: 6 are available, 1 is reserved for OMCI
16 are present: 15 are available, 1 is reserved for OMCI
32 are present: 31 are available, 1 is reserved for OMCI
32 are present: 30 are available, 2 are reserved for multicast and debugging
(1 of 2)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-3
3 — ONT and MDU general and interface technical specifications
ONT or MDU
T-CONTs per indoor or outdoor ONT
Package E MDUs
GEM ports per MDU
Release (1)
R04.02.42x
Maximum
31
Notes
32 are present: 31 are available, 1 is reserved for OMCI
T-CONTs per MDU
R04.02.3x
R04.02.3x
30
15
32 are present: 30 are available, 2 are reserved for multicast and debugging
16 are present: 15 are available, 1 is reserved for OMCI
Package F MDUs
GEM ports per MDU
T-CONTs per MDU
R04.02.3x
R04.02.3x
252
31
254 are present: 252 are available,
2 are reserved for multicast and debugging
32 are present: 31 are available, 1 is reserved for OMCI
Package G MDU
GEM ports per
O-0881V-A
T-CONTs per
O-0881V-A
Package H ONTs
GEM ports per
B-0404-A
T-CONTs per B-0404-A
All
All
All
All
126
63
38
39
128 are present: 126 are available,
2 are reserved for OMCI and debugging
64 are present: 63 are available, 1 is reserved for OMCI
38 in SW, 38 in HW
39 in SW, 39 in HW
(2 of 2)
Note
(1) The letter x following a release number denotes either a letter of the alphabet for maintenance releases or digit from 0 to 9 for minor releases.
3.3
Ethernet interface specifications
The Ethernet interface supports the following specifications:
• Ethernet ports are IEEE 802.3 and 802.3as compliant
• IEEE 802.1q, 802.1x port-based authentication, and 802.1p QoS classification per Ethernet port
• Layer 3 DSCP-to-802.1p mapping to allow layer 3 CoS over the layer 2 network
• RJ-45 connector(s)
• full or half duplex operations
• auto-negotiation or manual setting by operator
• 10/100 Base-T or 10/100/1000 Base-T (depending on the ONT type)
3-4 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3 — ONT and MDU general and interface technical specifications
Voice subsystem
ONT SoC-based technology provides a maximum of four POTS lines for voice services and can support either H.248 (Megaco) or session initiation protocol (SIP) signaling protocols. All POTS ports on an ONT must be configured to use the same signaling protocol. Signaling protocols can not be mixed.
The following signaling protocols are supported:
• for ONTs with four POTS lines, two lines can have both 3-way and 2-way call support, but the remaining two lines can support only 2-way calls
• support for G.711, G.726, and G.729 CODEC; the support for G.729 requires reduced channel number with software upgrade
• fax per T.38 on POTS lines
ONTs are compatible with all existing subscriber voice equipment including analog phones with tone or rotary dial capabilities, cordless phones, modems, fax machines, and caller ID boxes (Type I, Type II, and Type III).
Data and IP video subsystems over Ethernet interface
Data and IP video services are delivered through the Ethernet cable interface. The
Ethernet interface connects the subscriber premises equipment to the GPON.
A set-top box is required for the IP video service. The requirement for the television set associated with the set-top box is that it must be able to receive and display analog broadcasts on channel 3 or 4.
The Ethernet port can be set to the following:
• 10/100/1000BASE-T auto negotiation
• 10/100/1000BASE-T half duplex
• 10/100/1000BASE-T full duplex
• 10BASE-T auto-sensing
• 10BASE-T half duplex
• 10BASE-T full duplex
• 100BASE-T auto-sensing
• 100BASE-T half duplex
• 100BASE-T full duplex
• 1000BASE-T auto-sensing
• 1000BASE-T half duplex
• 1000BASE-T full duplex
ONTs support IP video service using the Internet Group Management Protocol
(IGMP). The IGMP snooping function supports:
• the ability to enable and disable IGMP per Ethernet and MoCA port
• the ability to age out multicast MAC addresses in the IGMP table
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-5
3 — ONT and MDU general and interface technical specifications
• G.984.3 compliant multicast using a single GEM port-ID for all video traffic (as mandated by G.984.3)
• up to of 64 video multicast streams per ONT
Note — For ONTs that have SoC technology on-board in a two-Ethernet port device, only one Ethernet UNI port at a time can be configured for IPTV and multicast streams.
3.4
POTS interface specifications
Table
3-3 lists specifications for the ONT voice service.
Table 3-3 Voice service specifications
Service features
Voice quality
DC supervisory range
G.168 echo cancellation
CODEC
Analog line impedance
Ringing voltage
Ringing capacity
Off-hook dc current
Maximum expected
DTMF signal level
Receive (D/A) loss
Transmit (A/D) loss
Loop start signaling
Loop length
Specifications for the ONT
Toll quality voice with a mean opinion score (MOS) of 4 or better
Total dc supervisory range of 750 Ω , allowing for 1000 ft (305 m) of 26
AWG CAT3 cable, CPE equipment, and a margin allocation
16 ms tail for near-end echo
G.711 (PCM 64 kb/s), G.729, and A-law and U-law encoding and decoding
600 Ω minimum of 40 Vrms
25 mA
0.0 dBm
4 dB
2 dB
—
Up to 984 ft (300 m)
Notes
(1) These items are determined by the country-specific VoIP configuration XML file. The values specified are for ANSI deployments.
(2) While the maximum ringing capacity for all ONTs is five REN per POTS line, some ONTs can support more than one POTS line at a time. For MDUs and business ONTs, the maximum ringing capacity is three POTS lines with a five REN load ringing simultaneously. For indoor ONTs, the maximum ringing capacity is two POTS lines with a five REN load ringing simultaneously.
3-6 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3 — ONT and MDU general and interface technical specifications
SIP Overview
Voice-over-IP (VoIP) implementations enable users to carry voice traffic over an IP network. A VoIP system consists of a number of different components: softswitch, gatekeeper, user agent, signaling gateway and a call manager etc., depending on the type of signaling-control protocol that is being used. There are a variety of signaling protocols defined by the standard bodies Internet Engineering Task Force (IETF) and
International Telecommunication Union (ITU), which specify how the user can setup signaling and bearer paths between the end devices. SIP signaling is based on a collection of IETF standards.
The ONT is based on an ASIC that provides L2 switching with filtering functions. In the upstream direction, the ONT assigns traffic to different GEM port IDs based on
L2 fields. In the downstream direction, the ONT performs a cross-connect between the GEM port ID and the LAN ports. The POTS analog interfaces are part of the
ONT. The VoIP signaling and bearer channels are terminated on the ONT. A VoIP client manages these terminations and POTS interfaces while performing SIP signaling with the soft switch.
SIP is a collection of IETF standards (i.e. RFCs). The main RFC for defining SIP is
RFC 3261 which contains the primary “methods” or signaling messages used for
SIP. Additional RFCs are defined that expand on this base to provided more complete functionality so that a complete set of call features that phone users are accustomed to can be supported. The connection model for the protocol consists of a series of signaling transactions with the soft switch which includes the media stream definitions using SDP (see RFC 2327). The intent of most signaling messages is to control and define the media stream used to convey the voice data between the endpoints of a phone call. The media stream or bearer channel has its own protocol,
RTP, which is defined in RFCs 3550 and 3551. In the SIP model, as with all VoIP models, the bearer channel is connected directly through the IP network, between the two endpoints, and is not normally connected to the softswitch itself, except for special cases of application services in support of voice conferencing, voice mail, or other special softswitch services.
The ONT SIP client is expected to control the analog states of the POTS line, detect and process dialing, generate tones and Caller ID FSK transmissions, while signaling with the softswitch to control the phone call, and establish/teardown the RTP bearer channel associated with the voice path.
VoIP-supporting ONTs have the following general features:
• The ONT supports simultaneous calls on all ports at any point of time.
• The ONT supports up to:
• two simultaneous 3-way Calls on a 2-port ONT
• three simultaneous 3-way Calls on a 4-port ONT
• six simultaneous 3-way Calls on an 8-port ONT
• The ONT supports a single VoIP client per ONT.
• The ONT has one MAC address associated the VoIP client.
• The ONT supports a configurable IP address for the VoIP client.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-7
3 — ONT and MDU general and interface technical specifications
3.5
POTS voice support for SIP
To ensure high quality delivery of SIP-based VoIP services in SIP Mode 1 (thin client), Alcatel-Lucent recommends the following values for the bandwidth profile for each POTS line:
• Committed Information Rate (CIR) of 150 Kb/s
• Excess Information Rate (EIR) of 150 Kb/s
• Delay Tolerance (DT) of 8
For multiple POTS lines providing SIP-based VoIP service in SIP Mode 1, use a multiple of the recommended per-line EIR and CIR values. For example, with 4
POTS lines, use CIR of 600 Kb/s, EIR of 600 Kb/s, and DT of 8.
To ensure high quality delivery of SIP-based VoIP services in SIP Mode 2 (thick client), Alcatel-Lucent recommends the following values for the bandwidth profile for each POTS line:
• CIR of 250 Kb/s
• EIR of 250 Kb/s
• DT of 8
For multiple POTS lines providing SIP-based VoIP service in SIP Mode 2, use a multiple of the recommended per-line EIR and CIR values. For example, with 4
POTS lines, use CIR of 1000 Kb/s, EIR of 1000 Kb/s, and DT of 8.
VDSL2 interface specifications
Similar to ADSL, VDSL2 operates over the copper wires in a telephone line to provide both high-bandwidth service and POTS, and is asymmetric in its downstream and upstream speeds. However, VDSL2 provides subscribers with a higher bit rate than multi-ADSL and can achieve speeds over 57 Mb/s downstream and 25 Mb/s upstream, compared with 24 Mb/s downstream and 1.3 Mb/s upstream with multi-ADSL. The maximum bit rates supported depend on deployment, noise environment, and Ethernet system restrictions. The high bit rate asymmetrical mode can be used for high-bandwidth video service, while the symmetrical bit rate mode can be used for business users or residential users who need symmetrical bit rate access. The VDSL2 ports support loop lengths of 300 meters nominal.
VDSL allows very high speed data transmission on a metallic twisted pair between the operator network and the customer premise. This service is provisioned by using the existing unshielded copper twisted pairs, without requiring repeaters. By using a
Frequency Division Multiplexing technique, the existing POTS or BR ISDN services can still be provided on the same wires. VDSL transceivers use Frequency Division
Duplexing (FDD) to separate upstream and downstream transmission.
Each end of the VDSL line is terminated by a VDSL Termination Unit (VTU), as
. The unit at the (optical) network side is the VTU-O (MDU) and the
Remote or Customer Premises (CP) unit is the VTU-R.
The High Pass Filter (HPF) blocks the POTS/ISDN signals towards the VTU, and the Low Pass Filter (LPF) blocks the VDSL signal towards the Local Exchange
(VTU-O side) or telephone set (VTU-R side).
3-8 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3 — ONT and MDU general and interface technical specifications
Figure 3-1 VDSL Termination Points
POTS splitter
Downstream
Upstream
POTS splitter
Data signals
VTU-O
Synchronization signals
OAM
POTS signals to CO
Metallic twisted pair
POTS signals to CPE
VTU-R
Data signals
21281
A bandplan is a partitioning of the frequency spectrum into non-overlapping frequency bands, each of which is allocated for either upstream or downstream transmission. ANSI and ETSI define a set of predefined VDSL BandPlan modes of operation. The VDSL BandPlan shall be configurable on a per port basis. The following bandplans are supported:
• bandPlanAnnexA998 17A, 30A
• bandPlanAnnexB998ADE 17a, 30a
• bandPlanAnnexB998E 17a, 30a
Table
3-4 describes ITU-T standards and related VDSL2 modes supported on the
MDUs.
Table 3-4 ITU-T standards supported
Standard
G.993.2
G.994.1
Description
VDSL2 over POTS operating above the POTS 25 kHz band with trellis
Handshake procedures for DSL transceivers
3.6
DS1/E1 interface specifications
The business ONT supports structured, unstructured, and fractional DS1 (100
Ω
) or
E1 (120
Ω
/75
Ω
) services. An external adapter is required for 75
Ω
. You cannot mix
DS1 and E1 services on the same ONT. You must configure both ports for either DS1 or E1 on the same ONT.
The CES subsystem encapsulates DS1 or E1 traffic received at the RJ-48C port using
MEF-8 packetization as Ethernet layer 2 for transport across the GPON. The CES encapsulation is removed before DS1 or E1 traffic from the GPON is sent to the DS1 or E1 lines at the subscriber side.
Structured DS1 or E1 services emulate fractional services where the 1.544 Mb/s
DS1, or 2.048 Mb/s E1, bandwidth is subdivided in to DS0 64 kb/s channels.
Framing is used to group together multiple DS0s when the service is structured or fractional. Unstructured services treat the full bandwidth of a DS1 or E1 link as though it were one large channel, ignoring any framing.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-9
3 — ONT and MDU general and interface technical specifications
CES encapsulation is a method of carrying TDM traffic in an Ethernet frame so that there is minimal loss of quality. The ISAM performs CES on the TDM traffic received at the ONT DS1 or E1 port using the MEF-8 payload structure for transport as Ethernet layer 2 packets over pseudo-wires (PW). The TDM payload within the
MEF-8 packet, whether it is structured or unstructured, is treated as a bit stream. The
MEF-8 packets are multiplexed along with other Ethernet layer 2 data packets at the
ONT before being transported across the GPON.
In unstructured mode, the payload size is fixed at eight DS0 frames per MEF-8 packet. For DS1, the payload length is fixed at 192 bytes per frame. For E1, the payload length is fixed at 256 bytes per frame. In structured mode, the payload length is determined from the encapsulation delay setting.
Table
3-5 lists the specifications supported for the DS1/E1 interface.
Table 3-5 DS1/E1 interface specifications
Item
DS1/E1 WAN interfaces
DS1/E1 CES over Ethernet layer 2
GPON
DS1 standards
Specification
Two RJ-48C ports configured for 100 Ω DS1, 120 Ω balanced E1, or 75 Ω unbalanced E1. An external adapter is required for 75 Ω .
MEF-8 packetization as IETF PWE3 pseudo-wires
E1 standards
Synchronization CES DS1/E1
Gigabit
Ethernet
AT&T TR-6421; ITU-T Rec. G.703, G.704
Structured (fractional) and unstructured DS1
ITU-T Rec. G.703, G.704, G.706, G.732, G.823
Structured (fractional) and unstructured E1
Upstream: A 16.384 MHz local oscillator or a derived clock (1)
from the GPON that is provided by the P-OLT
Downstream: Either a 16.384 MHz adaptive clock received from the PWE3 packet stream or a differential clock recovered from the PWE3 packet stream
A Gigabit Ethernet transmit reference clock of 125 MHz as per
IEEE 802.3
3-10
Note
(1) The upstream derived clock that is provided by the P-OLT is tied to the BIT clock and must be traceable to a network timing reference. The derived clock is used for differential clock recovery and for timing the upstream PWE3 packet streams in the absence of a valid TDM recovery clock.
CES Overview
Circuit Emulation Services (CES) encapsulation is supported on DS1 and E1 TDM traffic for transport as Ethernet layer 2 over the GPON using the Metro Ethernet
Forum standard MEF-8 payload structure and pseudo-wire (PW) technology. CES and the DS1 or E1 ports may be provisioned on the business ONT using a TL1 or an
EMS management session with the P-OLT.
The business ONT supports DS1 and E1 service connections at the subscriber premises. The following TDM link types are supported:
• structured (fractional) DS1 or E1
• unstructured DS1 or E1
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3 — ONT and MDU general and interface technical specifications
At the subscriber premises, the business ONT terminates DS1 or E1 links from the subscriber. The TDM traffic is adapted and packetized using MEF-8 pseudo-wire technology before being transported across the GPON. MEF-8 is the payload option that is used. The MEF-8 packets are multiplexed with the Ethernet layer 2 data traffic at the business ONT GPON port.
When the MEF-8 packets are received at the OLT, the packets are forwarded to the destination PSTN, typically via a voice gateway that is connected to the IP network.
shows the traffic flow.
Figure 3-2 CES DS1 or E1 traffic between the ONT and PSTN over the GPON via the OLT
Class 5 PSTN switch
DS1 or E1
Voice gateway
GE
EMS
L2
Ethernet cloud
GE
OLT
GPON
Business
ONT
DS1 or E1
DHCP server
CES clocking and synchronization
The same clocking reference at both ends of the DS1 or E1 link is required to meet the wander requirements of TDM traffic.
The business ONT can use one of two clocking sources for CES:
• a derived GPON clock at 16.384 MHz
• a 6.384 MHz local oscillator.
When the system clock for CES is derived from the GPON, the upstream P-OLT locks to the BIT clock and supplies the ONT with an Ethernet clock that is traceable to a network timing reference. The supplied Ethernet clock is used for differential clock recovery and for timing the upstream pseudo-wire MEF-8 packet streams in the absence of a valid TDM recovery clock. The local oscillator is only used if adaptive mode is selected.
The downstream TDM streams may be timed from one of two clocking sources:
• a 16.384 MHz adaptive clock received from the MEF-8 packet stream.
• a differential clock recovered from the MEF-8 packet stream via the GPON.
When the clock is received from the GPON, the GPON must be configured to send
RTP packets.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-11
3 — ONT and MDU general and interface technical specifications
3.7
In adaptive timing, a local, free-running 25 MHz clock is used. The generated bit rate is determined by the long-term average data rate. The attached DS1/E1 equipment must be loop timed. In differential timing, a 16.384 MHz reference clock is synchronized to the PON. Both ends of the DS1/E1 CES PW must use the same reference clock frequency and be synchronized to a common source. RTP is used to transport the transmit bit rate information. The DS1 or E1 equipment that is attached to the terminating CES PW devices must be loop timed. In loop timing, the receive clock rate is used for the transmit clock rate. The DS1/E1 equipment that is attached must be source timed, not loop timed.
Timestamps within the MEF-8 packets are used for carrying timing information across the network. Timestamp values are generated in differential format when the interface is operating in differential timing reference mode. Otherwise, the timestamp values represent absolute time.
RF video interface specifications for video overlay
The following section provides design guidelines for coaxial connectivity, configuration recommendations, and information based on the RF video receiver types used by Alcatel-Lucent ONTs and MDUs.
Warning — Operating equipment outside of its tested and documented performance characteristics and causing an optical overload may cause damage to equipment components, such as APD receivers. This can affect service delivery, and void any component or system warranties.
Note 1 — V-OLT is an optional network equipment that is used to distribute Radio Frequency (RF) video signal from service providers to the ONTs. This equipment is not part of the OLT or ONT system.
The following description of the V-OLT function is provided for informational purposes.
Note 2 — Alcatel-Lucent only guarantees ONT RF video output levels. Coaxial cable and splitter information in the following sections are provided as guidelines. See the coaxial and splitter vendor documentation for more information.
Video overlay overview
The system can provide RF video service through the video overlay function. The function operates downstream in the 1550 nm optical band. Signals sent over the overlay network are presented to the subscriber as RF signals from a video F-type connector in the ONT.
Caution — Video subscribers can only be provisioned on the
7342 ISAM FTTU system platform.
The V-OLT supports the full cable television (CATV) spectrum from 47 MHz to 862
MHz.
3-12 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3 — ONT and MDU general and interface technical specifications
Access to video services may require a Set-Top Box (STB) between the video output of the ONU equipment and other Customer Premises Equipment (CPE).
The V-OLT requires a separate Element Management System (EMS) to control video output signals from the V-OLT equipment.
The RF video service in the downstream 1550 nm optical band supports most available cable television (CATV) services, including standard analog broadcast channels, as well as standard and high definition digital broadcast channels. For access to these services, a set-top box may be required between the video output of the ONT equipment and the customer's television set.
Within the ONT functional blocks, the RF subsystem is an RF amplifier that produces the required RF output for the subscriber video equipment. The RF subsystem monitors the levels of optical and RF signals in support of the performance management functions. The RF video service is optional and
independent of the SoC functions. Figure 3-3
shows the video overlay system.
Figure 3-3 Video overlay system
Analog channels
Digital channels
Video head end
Broadcast video
Core transport Central office
1550 nm
(downstream RF video)
Video RF mux
Video optical transmitter
EDFA
Fiber (PON)
Distribution
1310 nm
(upstream)
Private network
WDM
Power
Processor
Major Alarm
Minor Alarm
OLT
VoD VoD server
IP
Network
Ethernet
Router
B
C
A Analog broadcast No STB needed
Digital broadcast STB needed
Broadcast and VoD STB needed
1490 nm
(downstream data)
ONT Home network
Coax
A
B
Coax
Ethernet
C
Coax
Radio Frequency Video Signal Distribution
The V-OLT uses Erbium Doped Fiber Amplifiers (EDFA). The distribution requires a Wavelength Division Multiplexer (WDM) to be overlaid into the fiber path.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-13
3 — ONT and MDU general and interface technical specifications
The distribution of the optical video signal is described as follows:
• The V-OLT receives an incoming wavelength optical signal with embedded video channels through a fiber path from the cable TV head-end equipment.
• The V-OLT amplifies and splits the optical signal into multiple optical feeds to the video coupler.
• The video coupler merges the video signal over the fiber paths.
• The fiber paths carry the optical signals between the P-OLT and the ONTs.
Coaxial connectivity in the home and design guidelines
Standard 75
Ω
coaxial cable can be used, including RG-6 or RG-59 coaxial cable.
Consider the following limitations when planning video deployments:
• ONTs and MDUs supporting video overlays only support specific split ratios on the coaxial distribution, based on the ONT or MDU video receiver. For for +18 dBmV receivers, the maximum split is 1:8
• The maximum supported length of RG-6 or RG-59 coaxial cable used for +18 dBmV units is 100 ft (30.48 m).
There are numerous criteria that effect RF video overlay. Figure 3-4 shows an
example of the factors affecting RF video overlay design and deployment.
Figure 3-4 RF video overlay design and deployment example with a +14 dBmV receiver
3-14
Maximum 100ft (30.48m) RG-6
-xxdB
Maximum 100ft (30.48m) RG-59
-xxdB
1:4 maximum split
Set-top box 1
ONT
Set-top box 4
T1 to -6 dB optics input
+14 dBmV +0 dBmV minimum
19061
Conditions that need to be confirmed to ensure proper RF video overlay service, as
, are based on:
• + 18 dBmV at the ONT
• 8 dB loss at the splitter in a 1:4 split; 6.6 dB loss in a 1:3 split, and 4.6 dB loss in a 1:2 split
• Cable attenuation loss based on frequency and cable type:
+ 18 dBmV (at the ONT at 450 MHz) - 8 dB (splitter) - XX dBmV (RG-59 cable loss at the highest frequency based on cable type, for example
400 MHz would be -7 dB) = Final dBmV (at set-top box or TV)
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3 — ONT and MDU general and interface technical specifications
For example: +18 - 8 - 7 = +3 dBmV.
+ 18 dBmV (at the ONT at 870 MHz) - 8 dB (splitter) - XX dBmV (RG-59 cable loss at the highest frequency based on cable type, for example
870 MHz would be -11 dB) = Final dBmV (at set-top box or TV)
For example: +19 - 8 - 11 = -1 dBmV.
The cable attenuation loss is based on the frequency and the type of cable used, as
Table 3-6 Typical cable attenuation loss value based on frequency
Frequency (MHz)
50
100
200
400
700
900
4.1
5.9
8.1
9.4
RG-6 coaxial per 100 ft (30.48 m) (dB)
1.9
2.7
4.9
7.0
9.7
11.1
RG-59 coaxial per 100 ft (30.48 m) (dB)
2.4
3.4
Be sure to properly plan and design the RF video deployment at the customer site.
The following is an example of a properly planned and designed RF video deployment. Based on 900 MHz frequency and 100 ft (30.48 m) of cable length, 0.6 dBmV is reached at the set-top box using RG-6 coaxial cable:
+18 dBmV - 8 dB - 9.4 dB = + 0.6 dBmV
The following is an example of an improperly planned and designed RF video deployment. Based on 900 MHz frequency and 100 ft (30.48 m) of cable length, -
1.1 dBmV is reached at the set-top box using RG-59 coaxial cable:
+18 dBmV - 8 dB - 11.1 dB = -1.1 dBmV therefore should not be used.
Note — It is the responsibility of the customer installation crew to ensure proper on-site layout of video distribution by verifying that the output power at the end devices, such as the TV, VCR, and STB, is between 0 to the limit of the ONT or MDU receiver’s dBmV.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-15
3 — ONT and MDU general and interface technical specifications
Configuration recommendations
You can control the quality of the output signal to the subscriber by specifying a number of parameters:
• If the ONT operates in AGC mode, you can specify the measurement offset to control the gain of the output signal, which ensures some measure of performance.
• You can set high and low optical power level thresholds for the downstream signal. An alarm is raised if either the high or the low optical power level threshold is crossed.
Consider the following before configuring RF video services:
• ONTs supporting RF video come with a 75
Ω
(F-type) coaxial interface connector. You may have to install the 75
Ω
coaxial F connector on the video cable.
• The F-type coaxial interface is typically connected to a four-way splitter in the home.
• You must use either RG-6 or RG-59 coaxial cable within the home.
• Ensure proper attenuation is inserted at the coaxial output to guarantee the following at the end of any coaxial drop:
• video signal is below 15.5 dBmV
• audio signal is below 2.55 dBmV per channel
• Tilt is a measure of the gain at the highest frequency relative to the lowest frequency. For example, if a receiver has a tilt of 5 dB, the RF level at 50 MHz may be 16 dBmV, the RF level at 450 MHz will be about 18 dBmV, and the RF level at 870 MHz will be (16 dBmV + 5 dB) = 21 dBmV. Tilt is an attempt to provide more gain at higher frequencies, to compensate for the higher loss at higher frequencies of typical RG-6 or RG-59 coaxial cable.
RF video service configuration requires the use of TL1 commands. These commands are issued at the P-OLT craft terminal.
14 dBmV RF video receivers
lists RF video interface specifications for ONTs with a 14 dBmV receiver.
Table 3-7 RF video service specifications for ONTs with 14 dBmV receivers
RF video features
RF output level
RF slope correction (tilt)
Optical power range
CNR
Specifications
+14 dBmV @ 450 MHz using a per analog channel measurement at the ONT output
5 to 8 dB from 50 to 870 MHz
+ 1.0 to –6.0 dB
45 dB
(1 of 2)
3-16 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3 — ONT and MDU general and interface technical specifications
RF video features
QAM signal-to-noise ratio
Measurement assumptions
Channel load
Digital backoff QAM-256
Digital backoff QAM-64
PON input CNR
Specifications
40 dB
80 analog and 33 QAM
6 dB (QAM-256)
10 dB (QAM-64)
52 dB
(2 of 2)
Note
(1) It is the responsibility of the customer installation crew to ensure proper on-site layout of video distribution by verifying that the output power at the end devices, such as the TV, VCR, and STB, is between 0 to 14 dBmV.
18 dBmV RF video receivers
Table
3-8 lists RF video interface specifications for ONTs with an 18 dBvM
receiver. The following ONTs support +18 dBmV receivers:
• I-241G series ONTs
• I-241W-P ONTs
Table 3-8 RF video interface specifications for ONTs with 18 dBmV receivers
RF video features
RF output level
RF slope correction (tilt)
Optical power range
CNR
CSO/CTB
MER
QAM signal-to-noise ratio
Measurement assumptions
Channel load
Digital backoff QAM-256
Digital backoff QAM-64
PON input CNR
Channel mix 80 analog/33
+18 dBmV @ 450 MHz using a per analog channel measurement
2 dB from 50 to 870 MHz
+1 to -6 dB
45 dB
53 dB
32 dB
40 dB
80 analog and 33 digital
6 dB
10 dB
52 dB
Channel mix 40 analog/63 digital
+18 dBmV @ 450 MHz using a per analog channel measurement
2 dB from 50 to 870 MHz
+2 to -7 dB
46 dB
55 dB
32 dB
40 dB
40 analog and 63 digital
6 dB
10 dB
52 dB
Channel mix 0 analog/135 digital
+12 dBmV @ 450 MHz using a per digital channel measurement
—
—
2 dB from 88 to 870 MHz
+1 to -9 dB
32 dB
40 dB
0 analog and 135 digital
6 dB
10 dB
52 dB
Note
(1) It is the responsibility of the customer installation crew to ensure proper on-site layout of video distribution by verifying that the output power at the end devices, such as the TV, VCR, and STB, is between 0 to 18 dBmV.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-17
3 — ONT and MDU general and interface technical specifications
3.8
SWRD interface specifications
The SWRD meets the following compliance and safety standards:
• UL safety (UL 60950-1)
• EU safety (IEC/EN 60950-1)
• IP rating NEMA 4 (IP 56)
• EMC emissions (U.S. and Canada) FCC part 15, class B
• EMC emissions (Europe) EN 55022 and 55024
The power specifications of the SWRD are as follows:
• input voltage range 12 +-2.0 V dc
• input current of 0.25 A
The power can be supplied by the ONT or MDU. In the ONT PoE case, jumpers must be configured on the EPC interface of the ONT to enable +12V power. In the MDU case, when the video return channel is configured for the SWRD Ethernet port, power is available.
lists the electrical specifications for the SWRD when all ports and cabling use IEEE 802.3-compliant materials.
Table 3-9 SWRD electrical specifications
Electrical specifications
Surge resistance on Ethernet ports
Surge resistance on RF ports
Forward pass band
Reverse operating frequency
Maximum length of power supply coaxial cable
Value
1.5 kV (1 positive, 1 negative)
1.5 kV (1 positive, 1 negative)
46 to 870 MHz
18.5 MHz
50 ft (15.24 m)
3-18
The environmental specifications of the SWRD are as follows
• operating temperature range is –40
°
F to 140
°
F (-40
°
C to 60
°
C) and to the equivalent of 105.8
°
F (41
°
C) with solar loading
• operating relative humidity is 5% to 95%, non-condensing
• operating altitude range is 200 ft (61 m) below mean sea level to 13 000 ft (3962 m) above mean sea level
• operating temperature can vary by 3
°
F (16.6
°
C) per minute, to the maximum and minimum ranges
The physical specifications of the SWRD are as follows
• housing dimensions: 6.78 in. wide by 1.29 in. deep by 5.77 in. high (17.45 cm by
3.38 cm by 14.66 cm)
• weight: 1.5 lb (0.68 kg)
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3.9
3 — ONT and MDU general and interface technical specifications
MoCA interface specifications
The following technical specifications apply to MoCA ONTs:
• RF interface connector: F-type with 75
Ω
impedance
• MoCA 1.0 and 1.1 compliant
• Network center frequency: 1 000 MHz
Note — MoCA ONTs only support MoCA v1.1 when connected to nodes that support MoCA v1.1. They revert to MoCA v1.0 if connected to nodes that only support MoCA v1.0.
MAC throughput (MAC rate) is the maximum rate at which Ethernet packets can be forwarded across the MoCA network while maintaining a PER of 10 -5 . Table
lists minimum MAC rates for the specified maximum PHY rates, for MoCA v1.0 and v1.1. This applies for flat channels between two intermediate devices with 100 Mb/s or 1 Gb/s Ethernet PHY interface in a two-node MoCA network, with 1518-byte packets.
PHY rate (Mb/s)
Table 3-10 MAC rate for PHY rates for 2-node network
Minimum MAC rate (Mb/s) per PHY rate (1)
MoCA v1.0
not specified
MoCA v1.1
176
167.5
Notes
(1) MAC rates are aggregate (half traffic in one direction, and half in the opposite direction) and assume a 1518-byte maximum frame size.
(2)
(3)
(4)
For MoCA v1.0 with less than 1518-byte frame size, the minimum aggregate MAC rate is 9500 packets/s.
For MoCA v1.1, packet aggregation allows a minimum MAC rate of 20 000 packets/s for 800-byte frames.
Maximum PHY rate is approximately 275 Mb/s when connected devices support optional QAM-256; otherwise the maximum PHY rate is approximately 250 Mb/s when using QAM-128.
The nominal transmit output power for MoCA ONTs is as follows:
• For Package B MoCA ONTs, the nominal transmit output power will be the values programmed via TL1 (range 0 to -30 dBm).
• For Package A MoCA ONTs, Table
3-11 lists the nominal transmit output power
variance for the values programmed via TL1.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-19
3 — ONT and MDU general and interface technical specifications
TL1 value (dBm)
-26 and lower
-23, -24, -25
-20, -21, -22
-17, -18, -19
-14, -15, -16
-11, -12, -13
-8, -9, -10
-5, -6, -7
-2, -3, -4
0, -1
Table 3-11 MoCA ONT nominal transmit output power
-2
0
-8
-5
-20
-17
-14
-11
Nominal transmit output power
-26
-23
3.10
Note
(1) The transmit output power values shown apply to MoCA ONTs (as measured from the F-connector output using a power meter).
RSSI specifications
Received signal strength indication (RSSI) is a measurement of radio signal strength at the receiver. Use of the RSSI metric is governed by the IEEE 802.11 standard, which does not define any relationship between RSSI value and power level in mW or dBm. RSSI measurements are specified without units and range in value from 0 to 255 with the highest value being referred to as RSSI Max. Defining RSSI values or power levels is the responsibility of the vendor.
According to the Alcatel-Lucent implementation of RSSI for ONTs, the RSSI value is expressed in power levels of dBm and is the measurement of the received optical signal level at 1490 nm in dBM. The RSSI range is -65.536 to +65.534. The absolute accuracy of the optical signal reading is +/-3.0 dB. Take this possible variation in measured signals into account when reading the metric values.
A RSSI value of zero occurs when the ONT is not connected to the PON or there is a loss of connectivity with the PON. In the latter case, the problem may be either with the ONT or PON.
Table
3-12 describes the supported RSSI specifications.
Table 3-12 RSSI specifications
Standard
IEEE 802.11
Description
A set of standards carrying out wireless local area network
(WLAN) computer communication in the 2.4, 3.6, and 5 GHz frequency bands
3-20 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3.11
3 — ONT and MDU general and interface technical specifications
Wi-Fi specifications
Wi-Fi is a term used to categorize WLAN devices based on the IEEE 802.11 standard. Only products certified as meeting this standard are called Wi-Fi.
Specifically, the certification process requires conformance to the IEEE 802.11 radio standards as well as the WPA and WPA2 security standards.
According to the Alcatel-Lucent implementation of Wi-Fi for ONTs, the following requirements must be met:
• Wi-Fi certified for IEEE 802.11a
• maximum transmit power (EIRP) equal to or greater than 200 mW (23.01 dBm) when operating in 802.11b mode
• Wi-Fi certified for Wi-Fi Multimedia (WMM) subset function of 802.11e
• Wi-Fi certified for Power Save, the U-APSD function of 802.11e
• maximum transmit power (EIRP) equal to or greater than 100 mW (20 dBm) when operating in 802.11g mode
• supports an 802.11h wireless access point
• supports WEP using a 104-bit key as identified in 802.11i
• Wi-Fi certified for WPA2-Personal that implements the mandatory elements of
802.11i
• Wi-Fi certified for WPA2-Enterprise
• 802.11g/n processing should not degrade the committed LAN-LAN and/or
LAN-WAN throughput rate
Table
3-13 for descriptions of the supported Wi-Fi specifications mentioned above.
Table 3-13 Wi-Fi specifications
Standards and amendments
IEEE 802.11
IEEE 802.11a
IEEE 802.11b
IEEE 802.11e
IEEE 802.11g
IEEE 802.11h
IEEE 802.11i
Description
A set of standards carrying out WLAN computer communication in the 2.4, 3.6, and 5 GHz frequency bands. The amendments in this table are Wi-Fi specific.
An amendment to the 802.11 specification adding a higher data rate of up to 54 Mb/s using the 5 GHz band
An amendment to the 802.11 specification extending throughput to up to 11 Mb/s using the 2.4 GHz band
An amendment to the 802.11 specification defining a set of QoS enhancements for wireless LAN applications through modifications to the MAC layer
An amendment to the 802.11 specification extending throughput to up to 54 Mb/s using the same 2.4 GHz band as 802.11b
An amendment to the 802.11 specification for spectrum transit power management extensions that regulate interference with satellites and radar using the 5 GHz frequency band
An amendment to the 802.11 specification defining security mechanisms for wireless networks
(1 of 2)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-21
3 — ONT and MDU general and interface technical specifications
3.12
Standards and amendments
IEEE 802.11n
Description
An amendment to the 802.11 specification extending throughput significantly to up to 600 Mbit/s with the use of four spatial streams at a channel width of 400 MHz
(2 of 2)
Ranging, discovery, and activation of ONTs
When the OLT system is ranging new ONTs, working ONTs must temporarily stop transmissions. This is done by opening a ranging window to discover new devices.
Two activation/ranging methods supported by the system:
• Configured-S/N:
The serial number of the ONT is registered in advance at the OLT.
• Discovered-S/N:
The serial number of the ONT is not registered at the OLT. It requires an automatic detection mechanism of the serial number of the ONT based on the operator-assigned SLID that is provisioned locally at the ONT and at the OLT for a match. In case a new ONT is detected, an ONT ID is assigned and the ONT is activated.
There are three triggers for initiating the activation of an ONT:
• The network operator enables the activation process to start when it is known that a new ONT has been connected.
• The OLT automatically initiates the activation process, when one or more of the previously working ONTs are 'missing', to see if those ONTs can return to service.
• The OLT periodically initiates the activation process, testing to see if any new
ONTs have been connected.
ONU activation
The activation procedure is performed by the exchange of upstream and downstream flags and Physical Layer Operations Administration and Maintenance (PLOAM) standard messages defined for GPON, as follows:
1 The ONT receives the requested GPON operating parameters from the OLT.
2 The ONT adjusts it parameters accordingly.
3 The OLT system discovers the serial number of a new connected ONT.
4 The OLT system assigns an ID to the ONT.
5 The OLT system measures the round-trip delay of the ONT transmission.
6 The OLT system notifies the ONT of the equalization delay.
7 The ONT adjusts the transmission phase to the notified value.
3-22 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
3.13
3 — ONT and MDU general and interface technical specifications
In the normal operating state, all the transmissions can be used for monitoring the phase of the arriving transmission. Based on the monitoring transmission phase information, the equalization delay can be updated.
ONT optical budget
This section provides the optical budget for all of the ONTs. Observe the safety
requirements with ONTs, which are Class 1 laser products. Figure 3-5
shows the
Class 1 laser product warning label attached to the ONT.
Figure 3-5 Class 1 laser product warning label
CLASS 1 LASER PRODUCT
18256
Warning — Operating equipment outside of its tested and documented performance characteristics and causing an optical overload may cause damage to equipment components, such as APD receivers.
This can affect service delivery, and void any component or system warranties.
Table
3-14 lists ONT optical budget information.
Table 3-14 ONT optical budget
Item
Operating temperature
Transmitting budgets
Tx nominal bit rate
Tx/Rx line code
Tx central wavelength
Detail
Ambient
—
Scrambled NRZ
Operating temperature
Tx reflection of equipment
Mask of Tx eye diagram
At Tx wavelength
G.984 burst mode
ORL of ODN at ONU Tx and Rx
Tx mean launched optical power for the ONT
More than
At ONT optical port
Tx launched optical power w/o input No input
Minimum Typical
See the data sheets for each device
Maximum
—
—
1290 nm
—
—
32 dB
+0.5 dBm
—
1244 Mb/s
—
—
—
G.984
—
—
—
—
1330 nm
–6 dB
—
—
+5.0 dBm
Tx extinction ratio
(1 of 2)
G.984 burst mode 10 dB
Sensitivity –10 dB
—
—
—
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
3-23
3 — ONT and MDU general and interface technical specifications
Item
Tolerance to Tx incident light
Tx –20 dB spectral width
Receiving budgets
Rx nominal bit rate
Rx wavelength
Detail
Rx consecutive identical bits
Rx tolerance to reflected optical power
—
Operating temperature
Rx reflection of equipment into ODN At Rx wavelength
Rx BER PRBS 2E23-1
Rx optical sensitivity for the ONT
Rx optical overload
At ONT optical port
At ONT optical port
CW
G.984 burst mode
Minimum
G.984 burst mode –15 dB
G.984 burst mode —
—
1480 nm
—
—
–27.0 dBm
–8 dBm
72 bits
—
(2 of 2)
Note
(1) Maximum guaranteed length is 18.6 mi (30 km).
Typical
—
—
Maximum
—
—
—
2488 Mb/s
—
—
1500 nm
— –20 dB
Less than 1E –10 —
— —
— —
—
10 dB
Note — The following information is for ETSI customers only:
• Power propagating in the fiber is 3.16 mW out of the ONT.
• The maximum modulation frequency is 1244 MHz.
• Operating wavelength is 1310 nm nominal in the ONT.
• Operation time of the automatic power reduction of the ONT transmitted optical power is 1 s or less.
3-24 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
4.2 ONT performance monitoring 4-2
4.3 ONT performance monitoring functions 4-3
4.4 ONT performance reporting 4-3
4.5 ONT performance monitoring data 4-6
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-1
4 — ONT and MDU statistics and performance monitoring
4.1
4.2
Overview
This chapter provides a detailed description of ONT performance monitoring.
ONT performance monitoring
Performance monitoring is a tool that provides up-to-date information to measure how well the system is doing. Performance monitoring data at the ONT level include counters and alarms that enable service providers to do the following:
• set a baseline for performance
• get a high-level view of the activity at a given point in the network
• detect problems when they occur
• diagnose the cause of problems
• plan for development and growth
Performance monitoring limitations
Table
4-1 describes performance monitoring limitations that need to be observed.
Table 4-1 Performance monitoring limitations
Montype
ONTENET
ONTL2UNI
ONTMOCA
PONONTTC
PONOLTTC
Counters collected by
ONT
OLT
Limitation
No hard-coded limit enforced
31 GEM port counters per each PON
4-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4.3
4.4
4 — ONT and MDU statistics and performance monitoring
ONT performance monitoring functions
The system provides the following functionality to simplify the usage of performance monitoring tools:
• Monitor at the edges per subscriber and per aggregate: The system provides counters at the edges where the subscriber originates and terminates. For example, these counters are performed on the ONTs and edge devices such as
BRAS or Edge Router. This counting empowers the service providers to solve their own monitoring issues.
• Perform error counting: The system provides error counters and aggregate counters at places other than where per subscriber significance is necessitated.
These counters are used to quickly identify and obtain a high level view of the activity at a given point in the network.
• Perform on-demand monitoring: This function allows the service provider to issue a count request on an ad hoc basis to isolate and monitor a situation further based on a criterion, such as per service, per VLAN, and per multicast stream.
Operators can use TL1, CLI, or an element management system (EMS) interface to:
• enable counters and set filters
• monitor performance
• view performance
ONT performance reporting
The system provides facilities that enable you to do the following:
• view statistics
• generate alarms
• report status
• capture diagnostic data
ONT statistical viewing
You can view statistics collected for the ONT using a TL1, CLI, or an EMS management session with the P-OLT.
Interval-based counters
For 15-min interval-based counters, you can use filters to define the scope of the statistics retrieved from the log file.
Depending upon the type of statistic you are retrieving, you can set filters to define any combination of the following:
• selected group of statistical parameters
• date range
• time range
• direction (Tx or Rx)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-3
4 — ONT and MDU statistics and performance monitoring
• location (near-end or far-end)
• count thresholds
If a command to retrieve performance statistics includes the current 15-min interval, a snapshot of the count at the time of the retrieval request is provided.
Note 1 — During ONT initialization, the current count of the first
15-min interval may be forced to restart due to the synchronization procedure between the LT unit on the P-OLT and the ONT.
Note 2 — Alcatel-Lucent recommends that users should wait for 30 seconds after the expiration of an interval before retrieving last interval counts. This will ensure reliable results as synchronization is then correct between the P-OLT and the ONTs.
Table
4-2 lists the 15-min ONT counters the system uses to collect performance
monitoring statistics.
Table 4-2 15-min ONT counters
Counter description
CES DS1/E1
Layer 1 on Ethernet ports
Layer 2 on Ethernet ports
Multimedia over coaxial alliance (MoCA) ports
TC-layer of the gigabit passive optical network (GPON) connection
Very-high-bit-rate digital subscriber line (VDSL2) ports
IGMP on multicast GEM port
Rolling counters
When a rolling counter is enabled, you can retrieve the current count using a TL1 or an EMS management session with the P-OLT. A snapshot of the current value in the rolling counter is displayed as an integer.
Table 4-3 lists the rolling counters the system uses to collect performance monitoring
statistics.
Table 4-3 Rolling counters
Counter description
GPON ports
ONT
✓
Some rolling counters can be set to automatically reset to zero after being retrieved.
See the operations and maintenance documentation for the OLT for restrictions, maximum count ranges, and the resetting of rolling counters.
4-4 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
TCA counters and alarms
The following performance monitoring counters can generate TCA alarms:
• errored or lost Tx and Rx fragments for upstream traffic across all GEM ports on the LT card on the modular and outdoor ONTs
• lost fragments (downstream) on aggregate GEM ports on the modular and outdoor ONTs
• dropped frames (upstream and downstream) and dropped bytes (upstream) for
Ethernet traffic on all MoCA, VDSL2, and Ethernet ports on the outdoor ONT
• Rx errored frames for ports on the ONT configured for MoCA
TCA alarms
TCA thresholds are applied to 15-min interval-based counters. An alarm is raised if the number of events occurring within a 15-min period exceeds the specified threshold. The following alarms are raised:
• ONTL2UNI alarms
• ONTMOCA alarms
• PONOLTTC alarms
• PONOLTTCONT alarms
• PONONTTC alarms
• xDSL (VDSL2) alarms
TCA provisioning
Performance monitoring counters are provisioned using either a TL1 or an EMS management session with the P-OLT. TCA is disabled by default. The procedure required for provisioning TCAs varies, depending on the type of interface or service you are monitoring.
• To enable TCA for VDSL2, you must first create a VDSL2 TCA profile, which specifies the threshold values for ES. SES and USA counters. The name and ID of the profile must then be assigned to a particular VDSL2 interface. Finally, enable TCA using the TL1 ONTVDSL performance monitoring provisioning commands or set the appropriate fields in the EMS.
• To enable TCA for all other counters, you do not need to create a profile. You only need to set the threshold value using TL1 or an EMS. After the threshold is set, enable TCA using the appropriate TL1 performance monitoring provisioning commands or set the appropriate fields in the EMS.
PON quality can be monitored with the following:
• abnormal incrementation of absolute BER values in each direction
• BER-related alarms such as SD/SF in upstream or RDI in downstream
• optical power at OLT and ONT side (RSSI)
Performance monitoring TCAs can also be used to flag dropped frames which can occur due to either data corruption on the PON or queue overflows. TCA values should be set based on historic normal behaviors for the network.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-5
4 — ONT and MDU statistics and performance monitoring
4.5
Status reporting
Status reports are available for the following:
• 802.1 end-user authentication
• 802.1 operator authentication
• iBridges
• ONT Ethernet ports
• ONT MoCA ports
• ONT optical link status levels
• ONT VDSL2 channels and ports
Diagnostic data capturing
In addition to status reports, the operator can issue a request to the ONT to store diagnostic data in nonvolatile memory, which the ONT can make available to a diagnosis technician in a remote centre for repair purposes. In addition to issuing a request, the LP MDU ONTs support the sending of diagnostic data to nonvolatile memory by use of a Save Data push button on the faceplate of the ONT. Diagnostic data includes:
• OMCI service interface provisioning data
• UPS alarm status
• Content of relevant hardware registers
• Amount of allocated and free RAM at time of receipt of request
• Processor stack at time of receipt of request
• CPU utilization at time of receipt of request
• SLID information
• Quantity of traffic flowing through the ONT at time of receipt of request
• State of the software load images
ONT performance monitoring data
The system provides a number of statistical counters in both the downstream and upstream direction for the ONT. These statistical counts are available as “always-on” counters and “on-demand” counters, and include the following:
• DS1/E1 ports
• Ethernet layer 1
• Ethernet layer 2
• GPON TC-layer (near-end)
• MoCA ports
• optical link status level
• VDSL2 channels and ports
• VoIP ports
• multicast GEM port
4-6 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
You can enable or disable counters using TL1. Counters are disabled by default unless indicated otherwise. Some counters have restrictions for the total number that you can activate at the same time. See the operations and maintenance
documentation for the OLT for information about any restrictions that apply to each performance statistic type.
Note — When the system date changes; for example, due to the move to daylight saving time, performance statistics collection is affected and an interval is either repeated or lost.
Monitoring thresholds and levels
For many performance management statistics retrieved using TL1, some or all of the following filter criteria apply. With a filter applied, only a matching subset of statistics counters are collected and displayed.
1 Monitoring level using the monlev parameter values [level, direction]. Only monitored values that meet the threshold specified are displayed. Where level is the threshold level and is an integer value (0...4294967295) and direction is a direction UP or DN. 1-UP is the default.
When the level is >=0, the value represents the threshold of statistics counter to show. When the direction is UP or DN, the value represents increase/decrease from threshold for counter to show.
For example, a configuration of [5,UP] would show only counters with values
>=5, while a configuration of [10,DN] would show only counters with values
<=10.
2 Facility location using the locn parameter values [NEND, FEND]. Where NEND if near end and FEND is far end.
3 Direction using the dirn parameter values (TX or RX) for the transmit or receive direction.
4 Monitoring period of either 15 minutes or 1 hour intervals.
Note — A performance monitoring limitation exists for threshold counters per ONT with a maximum of 128. This limitation is not apparent to the user. PM threshold counter resources are allocated as
ONTs and UNIs allow for the possibility of monitoring PM threshold crossings, even if these are not enabled by default. Depending on the line type, different numbers of TCA counter resources are allocated:
• ONT - 1
• VOIP - 1
• ENET - 1
• VDSL2 - 3
Counters
Counters are either interval-based counters or rolling counters.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-7
4 — ONT and MDU statistics and performance monitoring
4-8
Interval-based counters are statistical counts that are accumulated over a predefined time interval, such as a 15-min interval, and logged as an integer entry in a table. A total of 32 15-min intervals occurring over an 8-hr period are logged. After the 8 hr period has elapsed, new 15-min intervals overwrite the oldest entry recorded in the log file.
Rolling counters start at zero and count up to a maximum value. When the maximum value is reached, the counter restarts at zero. Unlike interval-based counters, no logs are maintained for rolling counters.
Counters serve to:
• ensure availability of up-to-date information about how the system is working
• help to establish threshold settings that represent acceptable performance under normal operational conditions. After collecting counters over a range of network activities and loads, a range of measurements can be defined, which serve as a reference point to detect problems when they occur
• detect error conditions, so that an alarm is raised when the count violates the threshold setting
• isolate and monitor a situation
• diagnose problems as they occur when an alarm is raised
Supported ONT counters
This section describes the performance monitoring statistics that are supported by the system. Performance monitoring data is not available for all ONTs. Table
the supported alarm types and counters. Table
4-5 provides reference links to all
supported ONT counters per ONT which are categorized into corresponding packages.
Note 1 — VDSL2 line and VDSL2 channel related statistics are only available for the modular and LP MDU ONT. The indoor, outdoor, and business ONTs do not support VDSL2.
Note 2 — CES DS1/E1 related statistics are only available for the business ONT. The indoor, outdoor, and modular ONTs do not support DS1 or E1.
Note 3 — All performance monitoring statistics listed are maintained and available on the P-OLT.
Table
4-4 describes the following alarm types and their counters that support ONT
performance monitoring statistics on the system:
•
•
•
•
,
,
PONONTTCVOIP , and PONONTTC (aggregate)
•
•
•
X/DSL2 line xTU-C (xDSL transceiver unit, central office)
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
Alarm type
ONTENET
ONTL2UNI
ONTMOCA
(1 of 3)
4 — ONT and MDU statistics and performance monitoring
•
X/VDSL2 line xTU-R (xDSL transceiver unit, remote terminal
•
•
Montype
FCSE
EC
LC
RBO
SCF
MCF
DT
IMTE
CSE
AE
IMRE
FTL
TBO
SQE
FRAMES
BYTES
MCFRAMES
DSDRPDFRMS
USDRPDFRMS
USFRAMES
DSFRAMES
USBYTES
DSBYTES
USMCFRAMES
DSMCFRAMES
RXFRMS
RXERRFRMS
Table 4-4 Supported ONT performance monitoring statistics
Interval
15 min
15 min
15 min
Counter description
Count of frame check sequence errors
Count of excessive collisions
Count of late collision
Count of received buffer overflows
Count of successfully transmitted single collision frames
Count of successfully transmitted multi-collision frames
Count of frames delayed due to deferred transmission
Count of unsuccessfully transmitted frames due to internal MAC transit errors
Count of carrier sense errors
Count of frames with alignment errors
Count of unsuccessfully received frames due to internal
MAC receive errors
Frames too long
Count of transmitted buffer overflows
Sequence errors
Count of frames upstream and downstream
Count of bytes upstream and downstream
Count of multicast frames upstream and downstream
Count of dropped frames downstream
Count of dropped frames upstream
Count of frames upstream
Count of frames downstream
Count of bytes upstream
Count of bytes downstream
Count of multicast frames upstream
Count of multicast frames downstream
Count of received frames upstream
Count of received errored frames upstream
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-9
4 — ONT and MDU statistics and performance monitoring
Alarm type
PONONTTC
PONONTMCTC
PONONTTCHSI
PONONTTCCES
PONONTTCFLOW
PONONTTCVOIP
PONONTTC (aggregate)
Interval
15 min
X/VDSL2 line 15 min
X/VDSL2 bearer/channel
15 min
Montype
TXBLOCKS
TXFRAGS
RXBLOCKS
RXFRAGS
LOSTFRAGS
ES
SES
UAS
FCCB
FCBB
SCCB
SCBB
TXBLK
BADGEMHDRS
LOSS or LOS
LOFS or LOF
LOPS
LOLS
REINIT
FAILINIT
INITTIMEOUTS
RXBLK
CV
FECC
CRC
(2 of 3)
Counter description
Transmitted GEM blocks upstream
Transmitted GEM fragments upstream
Received GEM blocks downstream
Received GEM fragments downstream
Transmitted and received lost GEM fragments downstream and upstream
Received bad GEM headers downstream
Loss of signal seconds upstream
Loss of frame seconds upstream
Loss of power seconds upstream
Loss of link seconds upstream
Modem re-initialization events upstream
Modem failed initialization events upstream
Initialization time outs upstream
Errored seconds upstream
Severely errored seconds upstream
Unavailable seconds upstream
Fast channel corrected blocks upstream
Fast channel bad blocks upstream
Slow channel corrected blocks upstream
Slow channel bad blocks upstream
Count of transmitted blocks downstream (fast or slow)
Count of received blocks upstream (fast or slow)
Code violations upstream
Forward error corrections upstream
Cyclic redundancy check
4-10 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
Alarm type
X/DSL2 line xTU-C
(xDSL transceiver unit, central office)
Interval
15 min
X/VDSL2 line xTU-R
(xDSL transceiver unit, remote terminal
15 min
CES PW
CES UNI
15 min
15 min
Montype
LOF or LOFS
LOS or LOSS
ES
SES
UAS
LI
FLI
ES
SES
UAS
CV
CV
FEC
LOF or LOFS
LOS or LOSS
FEC
TTLPKTS
MSGPKTS
MISORDRU
OVERRUN
MALFRMPKTS
PKTSLOST
LBITPKTS
ES
SES
BES
UAS
CSS
4 — ONT and MDU statistics and performance monitoring
Counter description
Loss of frame seconds near-end
Loss of signal seconds near-end
Loss of errored seconds near-end
Severely errored seconds near-end
Unavailable seconds near-end
Count of the total number of full initializations attempted on the line (successful and failed) during the accumulation period.
Count of the total number of failed full initializations during the accumulation period. A failed full initialization occurs when showtime is not reached at the end of the full initialization procedure.
Code violations near-end
Count of forward error correction near-end.
Loss of frame seconds far-end
Loss of signal seconds far-end
Loss of errored seconds far-end
Severely errored seconds far-end
Unavailable seconds far-end
Code violations far-end
Count of forward error correction far-end.
Count of total number of received packets (signaling and payload) upstream
Count of missing packets upstream
Count of misordered packets upstream that are usable
Count of buffer overruns and underruns upstream
Count of malformed packets upstream
Count of lost packets upstream (received packets with
R -bit set)
Count of packets received with L-bit set
Count of errored seconds upstream
Count of severely errored seconds upstream
Count of bursty errored seconds upstream
Count of unavailable seconds upstream
Count of controlled slip seconds upstream
(3 of 3)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-11
4 — ONT and MDU statistics and performance monitoring
Supported performance monitoring counters per package type of ONT
Table
4-5 provides reference links for each type of ONT to the various supported
performance monitoring statistics per package type:
•
•
•
•
•
•
•
•
•
Table 4-5 Supported performance monitoring counters per type of ONT
ONT Performance monitoring counters by montype
Package A indoor ONTs
I-010G-A
ONTENET statistics
ONTL2UNI statistics
ONTMOCA statistics
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-020E-B
I-020E-H
PONONTTC aggregate statistics
ONTENET statistics
ONTL2UNI statistics
ONTMOCA statistics
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
PONONTTC aggregate statistics
ONTENET statistics
ONTL2UNI statistics
ONTMOCA statistics
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-020G-F
PONONTTC aggregate statistics
I-020G-F PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-020G-F PONONTTC aggregate statistics
(1 of 5)
4-12 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
ONT
I-220E-A
Performance monitoring counters by montype
I-220E-A PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-241G-A
I-220E-A PONONTTC aggregate statistics
ONTENET statistics
ONTL2UNI statistics
ONTMOCA statistics
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
PONONTTC aggregate statistics
Package A outdoor ONTs
O-421E-B
ONTENET statistics
ONTL2UNI statistics
ONTMOCA statistics
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
PONONTTC aggregate statistics
Package B indoor ONTs
I-010G-B
ONTENET statistics
ONTL2UNI statistics
I-240G-B
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
PONONTTC aggregate statistics
ONTENET statistics
I-241G-B
ONTL2UNI statistics
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
PONONTTC aggregate statistics
ONTENET statistics
ONTL2UNI statistics
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
PONONTTC aggregate statistics
Package C indoor ONTs
(2 of 5)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-13
4 — ONT and MDU statistics and performance monitoring
ONT
I-010G-P
I-010G-Q
I-020G-P
I-040G-P
I-110G-P
I-240G-P
I-240G-Q
I-241G-P
Performance monitoring counters by montype
I-010G-P PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-010G-P PONONTTC aggregate statistics
ONTENET statistics
ONTL2UNI statistics
PONONTTC, PONONTCMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
PONONTTC aggregate statistics
I-020G-P PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-020G-P PONONTTC aggregate statistics
I-040G-P PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-040G-P PONONTTC aggregate statistics
I-110G-P PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-110G-P PONONTTC aggregate statistics
I-240G-P PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-240G-P PONONTTC aggregate statistics
ONTENET statistics
ONTL2UNI statistics
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
PONONTTC aggregate statistics
I-241G-P PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-241G-P PONONTTC aggregate statistics
(3 of 5)
4-14 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
ONT
I-241W-P
I-440G-P
Performance monitoring counters by montype
ONTENET statistics
ONTL2UNI statistics
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
PONONTTC aggregate statistics
I-440G-P PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
I-440G-P PONONTTC aggregate statistics
Package D ONTs
Package D ONTs or MDUs are not currently supported on the converged platform
Package E MDUs
O-8881V-P
O-8881V-P PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
O-00240V-P
O-8881V-P PONONTTC aggregate statistics
ONTL2UNI statistics
X/VDSL2 line xTU-C statistics
X/VDSL2 line xTU-R statistics
Package F MDUs
O-00160V-Q
O-00160V-Q ONTL2UNI statistics
O-00160V-Q X/VDSL2 line xTU-C statistics
O-00160V-Q X/VDSL2 line xTU-R statistics
O-00240V-Q
Package G MDUs
O-00240V-Q X/VDSL2 line xTU-R statistics
O-0881V-A
O-00240V-Q ONTL2UNI statistics
O-00240V-Q X/VDSL2 line xTU-C statistics
ONTL2UNI statistics
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
PONONTTC aggregate statistics
X/VDSL2 line statistics
X/VDSL2 bearer or channel statistics
Package H business ONTs
(4 of 5)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-15
4 — ONT and MDU statistics and performance monitoring
ONT
B-0404-A
Performance monitoring counters by montype
B-0404-A PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
B-0404-A PONONTTC aggregate statistics
(5 of 5)
Performance monitoring statistics for Package A ONTs
The following section identifies the supported performance monitoring statistics for
Package A type ONTs. A check mark indicates the statistic is supported on that ONT.
An empty cell indicates the statistic is not supported. A cell with n/a indicates the counter is not applicable to that type of ONT. The following tables are categorized by supported alarm types:
•
provides statistics for ONTENET type counters
•
provides statistics for ONTL2UNI type counters
•
provides statistics for ONTMOCA type counters
•
provides statistics for PONONTTC, PONONTMCTC,
PONONTTCHSI, PONONTTCCES, PONONTTCFLOW, and
PONONTTCVOIP, type counters
•
Table 4-10 provides statistics for PONONTTC (aggregate) type counters
Table 4-6 Package A ONT ONTENET performance monitoring statistics
ONT ONTENET statistics
Indoor
I-010G-A
I-020E-B
I-020E-H
I-020G-F
I-220E-A
I-241G-A
Outdoor
O-421E-B
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Note
(1) ONT O-421E-B part numbers 3FE 50683 AA and 3FE 50683 AE.
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓ ✓ ✓
4-16 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
ONT
Table 4-7 Package A ONT ONTL2UNI performance monitoring statistics
ONTL2UNI statistics
Indoor
I-010G-A
I-020E-B
I-020E-H
I-020G-F
I-220E-A
I-241G-A
Outdoor
O-421E-B
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Table 4-8 Package A ONTs ONTMOCA performance monitoring statistics
ONT ONTMOCA statistics
RXFRMS RXERRFRMS
Indoor
I-010G-A
I-020E-B
I-020E-H
I-020G-F
I-220E-A
I-241G-A
Outdoor
O-421E-B n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
✓
✓
✓
✓
✓
✓
✓
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-17
4 — ONT and MDU statistics and performance monitoring
Table 4-9 Package A ONT PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP performance monitoring statistics
ONT PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
Indoor
I-010G-A
I-020E-B
I-020E-H
I-020G-F
I-220E-A
I-241G-A
Outdoor
O-421E-B
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Note
(1) TC layer OAM performance monitoring is not supported on the OLT R04.00.10 therefore LOSTFRAGS and TXFRAG counters are not supported on indoor ONTs.
Table 4-10 Package A ONT PONONTTC aggregate performance monitoring statistics
ONT PONONTTC aggregate statistics
4-18
Indoor
I-010G-A
I-020E-B
I-020E-H
I-020G-F
I-220E-A
I-241G-A
Outdoor
O-421E-B
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
Performance monitoring statistics for Package B ONTs
The following section identifies the supported performance monitoring statistics for
Package B type ONTs. A check mark indicates the statistic is supported on that ONT.
An empty cell indicates the statistic is not supported. A cell with n/a indicates that the counter is not applicable to that type of ONT. The following tables are categorized by supported alarm types:
•
Table 4-11 provides statistics for ONTENET type counters
•
Table 4-12 provides statistics for ONTL2UNI type counters
•
Table 4-13 provides statistics for PONONTTC, PONONTMCTC,
PONONTTCHSI, PONONTTCCES, PONONTTCFLOW, and
PONONTTCVOIP type counters
•
Table 4-14 provides statistics for PONONTTC (aggregate) type counters
Table 4-11 Package B ONT ONTENET performance monitoring statistics
ONT ONTENET statistics
Indoor
I-010G-B
I-240G-B
I-241G-B
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
ONT
Table 4-12 Package B ONTs ONTL2UNI performance monitoring statistics
ONTL2UNI statistics
Indoor
I-010G-B
I-240G-B
I-241G-B
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-19
4 — ONT and MDU statistics and performance monitoring
Table 4-13 Package B ONT PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, PONONTTCVOIP performance monitoring statistics
ONT PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, PONONTTCVOIP statistics
Indoor
I-010G-B
I-240G-B
I-241G-B
✓
✓
✓
✓
✓
✓
Note
(1) TC layer OAM performance monitoring is not supported on the OLT R04.00.10 therefore LOSTFRAGS and TXFRAG counters are not supported on indoor ONTs.
Table 4-14 Package B ONT PONONTTC (aggregate) performance monitoring statistics
ONT PONONTTC (aggregate) statistics
Indoor
I-010G-B
I-240G-B
I-241G-B
✓
✓
✓
✓
✓
✓
✓
✓
✓
Performance monitoring statistics for Package C ONTs
The following section identifies the supported performance monitoring statistics for
Package C type ONTs. A check mark indicates the statistic is supported on that ONT.
An empty cell indicates the statistic is not supported. A cell with n/a indicates that the counter is not applicable to that type of ONT. The following tables are categorized by supported alarm types:
•
Table 4-15 provides statistics for ONTENET type counters
•
Table 4-16 provides statistics for ONTL2UNI type counters
4-20 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
•
Table 4-17 provides statistics for PONONTTC, PONONTMCTC,
PONONTTCHSI, PONONTTCCES, PONONTTCFLOW, and
PONONTTCVOIP type counters
•
Table 4-18 provides statistics for PONONTTC aggregate type counters
ONT
Note — If you have trouble accessing Package C ONTs performance monitoring statistics using TL1, please contact your Alcatel-Lucent support representative for more information about how to access and retrieve performance monitoring type counters.
Table 4-15 Package C ONT ONTENET performance monitoring statistics
ONTENET statistics
Indoor
I-010G-P
I-010G-Q
I-020G-P
I-040G-P
I-110G-P
I-240G-P
I-240G-Q
I-241G-P
I-241W-P
I-440G-P
✓
✓
✓
✓
✓
✓
✓
✓ ✓ ✓ ✓ ✓ ✓
✓
✓
✓ ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓ ✓
✓
✓ ✓
✓ ✓
✓
✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓
✓
✓
✓
✓
✓
✓
✓ ✓
✓
✓
✓
✓ ✓ ✓
Note
(1) A 5 second polling window limitation exists on the ONT, therefore the margin of error for each
15-min window is 5 seconds
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-21
4 — ONT and MDU statistics and performance monitoring
ONT
Table 4-16 Package C ONT ONTL2UNI performance monitoring statistics
ONTL2UNI statistics
Indoor
I-010G-P
I-010G-Q
I-020G-P
I-040G-P
I-110G-P
I-240G-P
I-240G-Q
I-241G-P
I-241W-P
I-440G-P
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Note
(1) A 5 second polling window limitation exists on the ONT, therefore the margin of error for each
15-min window is 5 seconds
Table 4-17 Package C ONT PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, PONONTTCVOIP performance monitoring statistics
ONT PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, PONONTTCVOIP statistics
Indoor
(1 of 2)
4-22 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
ONT
4 — ONT and MDU statistics and performance monitoring
PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, PONONTTCVOIP statistics
I-010G-P
I-010G-Q
I-020G-P
I-040G-P
I-110G-P
I-240G-P
I-240G-Q
I-241G-P
I-241W-P
I-440G-P
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
(2 of 2)
Notes
(1) A 5 second polling window limitation exists on the ONT, therefore the margin of error for each
15-min window is 5 seconds
(2)
(3)
TC layer OAM performance monitoring is not supported on the OLT R04.00.10 therefore
LOSTRFRAGS and TXFRAG counters are not supported on indoor ONTs.
The lost GEM fragment counter supports downstream direction only. Upstream direction is not supported.
Table 4-18 Package C ONT PONONTTC aggregate performance monitoring statistics
ONT PONONTTC (aggregate) statistics
Indoor
(1 of 2)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-23
4 — ONT and MDU statistics and performance monitoring
ONT PONONTTC (aggregate) statistics
4-24
I-010G-P
I-010G-Q
I-020G-P
I-040G-P
I-110G-P
I-240G-P
I-240G-Q
I-241G-P
I-241W-P
I-440G-P
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
(2 of 2)
Notes
(1) The lost GEM fragment counter supports downstream direction only. Upstream direction is not supported.
(2) A 5 second polling window limitation exists on the ONT, therefore the margin of error for each
15-min window is 5 seconds
Performance monitoring statistics for Package E ONTs
The following section identifies the supported performance monitoring statistics for
Package E type ONTs. A check mark indicates the statistic is supported on that ONT.
An empty cell indicates the statistic is not supported. A cell with n/a indicates that the counter is not applicable to that type of ONT. The following tables are categorized by supported alarm types:
•
Table 4-19 provides statistics for ONTENET type counters
•
Table 4-20 provides statistics for ONTL2UNI type counters
•
Table 4-21 provides statistics for PONONTTC, PONONTMCTC,
PONONTTCHSI, PONONTTCCES, PONONTTCFLOW, PONONTTCVOIP type counters
•
Table 4-22 provides PONONTTC aggregate type counters
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
•
Table 4-23 provides X/VDSL2 line xTU-C type counters
•
Table 4-24 provides X/VDSL2 line xTU-R type counters
ONT
Note — If you have trouble accessing Package E type ONTs or
MDUs performance monitoring statistics using TL1, please contact your Alcatel-Lucent support representative for more information about how to access and retrieve performance monitoring type counters.
Table 4-19 Package E MDU ONTENET performance monitoring statistics
ONTENET statistics
O-8881V-P
O-00240V-P
✓ ✓ ✓ ✓ ✓ ✓ ✓
Note
(1) A 5 second polling window limitation exists on the ONT, therefore the margin of error for each
15-min window is 5 seconds
ONT
Table 4-20 Package E MDU ONTL2UNI performance monitoring statistics
ONTL2UNI statistics
O-8881V-P
O-00240V-P
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Note
(1) A 5 second polling window limitation exists on the ONT, therefore the margin of error for each
15-min window is 5 seconds
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-25
4 — ONT and MDU statistics and performance monitoring
Table 4-21 Package E MDU PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, PONONTTCVOIP performance monitoring statistics
ONT PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, PONONTTCVOIP statistics
O-8881V-P
O-00240V-P
✓ ✓ ✓ ✓
Note
(1) A 5 second polling window limitation exists on the ONT, therefore the margin of error for each
15-min window is 5 seconds
Table 4-22 Package E MDU PONONTTC aggregate performance monitoring statistics
ONT PONONTTC (aggregate) statistics
4-26
O-8881V-P
O-00240V-P
✓ ✓ ✓ ✓ ✓
Notes
(1) A 5 second polling window limitation exists on the ONT, therefore the margin of error for each
15-min window is 5 seconds
(2) The lost GEM fragment counter supports downstream direction only. Upstream direction is not supported.
Table 4-23 Package E MDU X/VDSL2 line xTU-C performance monitoring statistics
ONT X / VDSL2 line xTU-C statistics
O-8881V-P
O-00240V-P n/a
✓ n/a
✓ n/a
✓ n/a
✓ n/a
✓ n/a
✓ n/a
✓ n/a
✓ n/a
✓
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
Table 4-24 Package E MDU X/VDSL2 line xTU-R performance monitoring statistics
ONT X / VDSL2 line xTU-R statistics
O-8881V-P
O-00240V-P n/a
✓ n/a
✓ n/a
✓ n/a
✓ n/a
✓ n/a
✓ n/a
✓
Performance monitoring statistics for Package F ONTs
The following section identifies the supported performance monitoring statistics for
Package F type ONTs. A check mark indicates the statistic is supported on that ONT.
An empty cell indicates the statistic is not supported. A cell with n/a indicates that the counter is not applicable to that type of ONT. The following tables are categorized by supported alarm types:
•
Table 4-25 provides statistics for ONTL2UNI type counters
•
Table 4-26 provides statistics for X/VDSL2 line xTU-C type counters
•
Table 4-27 provides statistics for X/VDSL2 line xTU-R type counters
Table 4-25 Package F MDU ONTL2UNI performance monitoring statistics
ONT ONTL2UNI statistics
O-00160V-Q
O-00240V-Q
✓
✓
✓
✓
Table 4-26 Package F MDU X/VDSL2 line xTU-C performance monitoring statistics
ONT X / VDSL2 line xTU-C statistics
O-00160V-Q
O-00240V-Q
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-27
4 — ONT and MDU statistics and performance monitoring
Table 4-27 Package F MDU X/VDSL2 line xTU-R performance monitoring statistics
ONT X / VDSL2 line xTU-R statistics
O-00160V-Q
O-00240V-Q
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Performance monitoring statistics for Package G ONTs
The following section identifies the supported performance monitoring statistics for
Package G type ONTs. A check mark indicates the statistic is supported on that ONT.
An empty cell indicates the statistic is not supported. A cell with n/a indicates that the counter is not applicable to that type of ONT. The following tables are categorized by supported alarm types:
•
Table 4-28 provides statistics for ONTL2UNI type counters
•
Table 4-29 provides statistics for PONONTTC, PONONTMCTC,
PONONTTCHSI, PONONTTCCES, PONONTTCLFOW, and
PONONTTCVOIP type counters
•
Table 4-30 provides statistics for PONONTTC aggregate type counters
•
Table 4-31 provides statistics for X / VDSL2 line type counters
•
Table 4-32 provides statistics for X / VDSL2 bearer or channel type counters
Table 4-28 Package G MDU ONTL2UNI performance monitoring statistics
ONT ONTL2UNI statistics
O-0881V-A ✓ ✓ ✓ ✓ ✓
Table 4-29 Package G MDU PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP performance monitoring statistics
ONT PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
4-28
O-0881V-A ✓ ✓ ✓ ✓ ✓
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
4 — ONT and MDU statistics and performance monitoring
Note
(1) TC layer OAM performance monitoring is not supported on the OLT R04.00.10 therefore LOSTFRAGS and TXFRAG counters are not supported on indoor ONTs.
Table 4-30 Package G MDU PONONTTC aggregate performance monitoring statistics
ONT PONONTTC aggregate statistics
O-0881V-A ✓ ✓
Table 4-31 Package G MDU ONT X / VDSL2 line performance monitoring statistics
ONT X / VDSL2 line statistics
O-0881V-A ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Note
(1) The performance monitoring parameter PM_VLINE_REINIT includes these counters: modem reinitializations, initialization failures, and initialization time-outs.
Table 4-32 Package G MDU X / VDSL2 bearer or channel performance monitoring statistics
ONT X / VDSL2 bearer or channel statistics
O-0881V-A ✓ ✓
Performance monitoring statistics for Package H ONTs
The following section identifies the supported performance monitoring statistics for
Package H type ONTs. A check mark indicates the statistic is supported on that ONT.
An empty cell indicates the statistic is not supported. A cell with n/a indicates that the counter is not applicable to that type of ONT. The following tables are categorized by supported alarm types:
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-29
4 — ONT and MDU statistics and performance monitoring
ONT
Table 4-33 Package H ONT ONTENET performance monitoring statistics
ONTENET statistics
Business
B-0404-A ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
ONT
Table 4-34 Package H ONT ONTL2UNI performance monitoring statistics
ONTL2UNI statistics
Business
B-0404-A ✓ ✓ ✓ ✓ ✓
Table 4-35 Package H ONT PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP performance monitoring statistics
ONT PONONTTC, PONONTMCTC, PONONTTCHSI, PONONTTCCES,
PONONTTCFLOW, and PONONTTCVOIP statistics
Business
B-0404-A ✓ ✓
Table 4-36 Package H ONT PONONTTC aggregate performance monitoring statistics
ONT PONONTTC aggregate statistics
Business
(1 of 2)
4-30 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
ONT
B-0404-A
(2 of 2)
4 — ONT and MDU statistics and performance monitoring
PONONTTC aggregate statistics
✓ ✓
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
4-31
4 — ONT and MDU statistics and performance monitoring
4-32 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
5.4 Accessing or disconnecting from the HTTP or a CLI interface 5-11
5.5 Retrieving product information for an ONT 5-18
5.7 Retrieving uptime of an ONT 5-27
5.9 Checking status of LEDs 5-31
5.10 Checking ranging state of an ONT 5-35
5.11 Monitoring software download to an ONT 5-37
5.13 Tracing OMCI and protocol traffic 5-43
5.14 Activating an ONT using an SLID 5-54
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-1
5 — ONT management using an ONT interface
5.15 XML file configuration data for package C ONTs 5-68
5-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5.1
5.2
5 — ONT management using an ONT interface
About this document
This document provides the information necessary to manage an ONT at a local site using an HTTP interface, CLI interface, CLI interface for Package C ONTs, or butt set.
Intended audience
This document is intended for field technicians who are responsible for installing or troubleshooting ONTs at a local site.
Conventions used
This document uses the typographical conventions described in Table
Table 5-1 Typographical conventions
Appearance graphical user interface
↵
Description
Text that is displayed in a graphical user interface
Press the Return or Enter key on the keyboard
About the interfaces
The HTTP and CLI interfaces provide access to utilities that enable a field technician to:
• retrieve product information about an ONT, such as vendor name, firmware, type of ONT, and serial number
• retrieve operational information about an ONT, to monitor events such as the operational states, uptime, receive signal strength indication (RSSI), status of
LEDs, and ranging state of the ONT
• monitor a software download to an ONT
• reboot or reset an ONT to recover from connection, power, software download, and other failures
• perform OMCI and protocol tracing for problem diagnosis and resolution
• enter the SLID at an ONT, to activate ONTs with their provisioning data and services using the SLID method, and to clear the SLID when an ONT is removed
Package C ONTs have a unique CLI that enable a field technician to retrieve and modify the SLID and HTTP interface for viewing the current and entering a new
SLID. For a list of Package C ONTs, see Performance monitoring statistics for
.
The butt set allows a field technician to enter or clear the SLID at an ONT using a
POTS port.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-3
5 — ONT management using an ONT interface
Utilities
Retrieval of ONT product information
Retrieval of ONT states
Retrieval of ONT uptime
Retrieval of RSSI
Retrieval of status of LEDs
Retrieval of ranging state
Retrieval of software download state
ONT reset
Supported utilities and ONTs
An ONT interface is accessible through a port on the ONT.
• HTTP interfaces are accessible through an Ethernet connection on indoor ONTs.
• The CLI interface is accessible through an Ethernet connection on indoor ONTs, and a craft connection on outdoor ONTs.
• The CLI interface for Package C ONTs is accessible through an Ethernet connection or craft connection on indoor and outdoor ONTs and MDUs.
• The butt set is used through a POTS connection on an indoor or outdoor ONT.
Table
5-2 identifies the utilities and the ONTs that these interfaces support.
Table 5-2 Supported utilities and ONTs
Supported
ONTs using
HTTP interface
Indoor ONTs with Ethernet connection
Supported
ONTs using CLI interface
Indoor ONTs with Ethernet connection
Outdoor ONTs with serial
RS-232 craft interface
Supported
ONTs using
Package C
ONT HTTP interface
Indoor ONTs with Ethernet connection
Supported
ONTs using
Package C
ONT CLI interface
Supported
ONTs using a butt set
OMCI and protocol tracing
Entry and clearing of SLID
Indoor ONTs with Ethernet connection
Indoor ONTs with Ethernet connection
Indoor ONTs with Ethernet connection
Indoor and outdoor ONTs and MDUs with
Ethernet or craft connections
Indoor and outdoor ONTS with POTS connection
5-4 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Security
The HTTP and CLI interfaces are password-protected to prevent unauthorized access to utilities. In addition, each ONT has a security setting that specifies the access level of a user to the HTTP and CLI interface utilities, after the ONT is ranged. User access levels are as follows:
• read-write access, which grants a user read and write access to all utilities
• read-only access, which grants a user read-only access to the SLID, ranging state, and RSSI of the ONT
• no access, which denies a user access to all utilities
Note 1 — Contact the CO for the level of access that has been set for a specific ONT.
Note 2 — The HTTP and CLI interfaces require a specific username and password. Contact your Alcatel-Lucent technical support representative for username and password information.
Note 3 — The following exceptions apply to security.
• If the PON is out of service, you have read-only access to the
SLID, ranging state, and RSSI of the ONT, regardless of the access level of the ONT.
• If the ONT or the Ethernet port on the ONT is out of service, you cannot log in to the ONT using the HTTP or CLI interface.
HTTP interface
The HTTP interface is GUI-based. Figure
shows a sample HTTP interface, with the main parts of the interface labeled. The following sections describe these parts.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-5
5 — ONT management using an ONT interface
Figure 5-1 HTTP interface
5-6
Main options and sub-options
The HTTP interface has five main options, which are referred to as tabs in this document. Each option has one or more sub-options. Table
and their related sub-options.
Table 5-3 Options and sub-options
Main option
Product information
States management
ONT management
Trace management
SLID management
Sub-option
—
ONT status
Uptime
RSSI
LED
Ranging
Download state
Reset ONT
—
SLID
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Window and status bar
Each main option opens a window with one or more sub-options as tabs. The window
always opens with the first sub-option preselected. For example, Figure 5-2
shows the States Management window with the ONT status sub-option preselected.
Figure 5-2 States Management window with ONT status sub-option shown
To select another sub-option you must click on the applicable tab. The content of the window changes to reflect your new selection. A status bar at the top of the window displays information about the current state of the window. A Refresh button at the bottom of the window refreshes the contents of the window with the current settings for the ONT.
CLI interface
The CLI interface is menu-driven, and consists of two menus: the main menu and a secondary menu. Each menu contains a number of options from which you can choose. To navigate to the secondary menu, you must choose option 8. More options from the main menu. Figures
5-4 show the main and secondary menus.
Figure 5-3 Main menu
Main menu
===============
1.
2.
Enter SLID in volatile mode
Enter SLID in permanent mode
3.
4.
5.
6.
Enter SLID in registration mode
Retrieve SLID
Clear SLID
Retrieve ranging state
7.
8.
9.
Retrieve optical level
More options
Log out
Enter choice :
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-7
5 — ONT management using an ONT interface
Figure 5-4 Secondary menu
Secondary menu
===============
1.
2.
Retrieve firmware version
Retrieve ONT status
3.
4.
5.
6.
Retrieve uptime
Retrieve ONT type
Retrieve ONT serial number
Retrieve ONT LED status
7.
8.
Retrieve download progress
Reboot ONT
9.
Enable tracing
10.
Upload traces
11.
Return to main menu
Enter choice :
Option selection
To choose an option from the main or secondary menu, type the number of the option in the menu prompt Enter choice: and press
↵
. If you enter an invalid option number, the system responds with the message Unknown option and displays the menu again.
CLI interface for Package C ONTs
The CLI interface for Package C ONTs is menu-driven, and consists of two menus: the login menu and SLID menu. Each menu contains a number of options from which you can choose. To navigate to the SLID menu, you must successfully login.
Following are the login and SLID menus.
login menu
<L>ogin
E<x>it
5-8
SLID menu
Retrieve<S>lid
<M>odify Slid
<R>eboot
E<x>it
Option selection
To choose an option from the login or SLID menu, type the letter (in either uppercase or lowercase) in the option that appears between angle brackets (<>). For example, to modify the SLID type either M or m in response to the <M>odify Slid menu option.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5.3
5 — ONT management using an ONT interface
Butt set
A butt set is a portable telephone used by technicians for installing and testing local loop telephone lines.
A typical butt set integrates an ear piece, a mouthpiece, a dialing interface, and a set of test leads for connecting to the telephone circuit. Most butt sets use a variant of the standard 12-button DTMF keypad. Butt sets are designed to be used with analog
POTS lines.
Quick reference
Table
5-4 provides quick access to the HTTP interface, CLI interface, and butt set
procedures in this document.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-9
5 — ONT management using an ONT interface
Table 5-4 Tasks and procedures
Task
Accessing or disconnecting from the HTTP or a CLI interface
Retrieving product information for an ONT
Checking ranging state of an ONT
Monitoring software download to an
Tracing OMCI and protocol traffic
Procedure using
HTTP interface
Procedure using
CLI interface
—
HTTP interface using the first
To disconnect from the HTTP interface
To retrieve product information for an ONT
To check the ranging state of an ONT
To check status of software download
CLI interface using a craft port
To disconnect from the CLI interface
To retrieve product information for an ONT
To check the ranging state of an ONT
To check the status of software download
To trace in real time or logging mode
Procedure using
Package C ONT
HTTP interface
—
—
—
Procedure using
Package C ONT
CLI interface
CLI interface using a craft port
To disconnect from the CLI interface
—
Procedure using butt set
—
To retrieve product information for an ONT
—
—
—
—
—
—
Protocol trace for a Package C
—
—
—
To disable tracing in logging mode
To copy a trace log to a TFTP server
—
(1 of 2)
5-10 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Task
Procedure using
HTTP interface
Procedure using
CLI interface
Procedure using
Package C ONT
HTTP interface
—
Procedure using
Package C ONT
CLI interface
To retrieve the current SLID settings
—
Procedure using butt set
—
To clear the SLID using a butt set
(2 of 2)
5.4
Accessing or disconnecting from the HTTP or a CLI interface
This section shows you how to:
• access the HTTP or a CLI interface
• disconnect from the HTTP or a CLI interface
Prerequisites
The prerequisites are:
• The ONT is installed.
• The ONT is in service.
• For an indoor ONT, the first Ethernet port, which is typically labeled 1 on the
ONT, is in service.
• For an outdoor ONT, the ONT has a serial RS-232 craft interface.
• For an indoor Package C ONT, the ONT has an Ethernet port in service.
Procedures using HTTP interface
The HTTP interface is accessible through the first Ethernet port on an indoor ONT using a computer or laptop with an HTTP client. The ONT must support an HTTP server, and the computer must have a supported HTTP client (Web browser).
Note — Contact your Alcatel-Lucent technical support representative for a list of supported Web browsers.
The following procedures provide the steps to access and to disconnect from the
HTTP interface using the first Ethernet port.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-11
5 — ONT management using an ONT interface
Procedure 5-1 To access the HTTP interface using the first Ethernet port
1 Connect a computer or laptop with an HTTP client to the first Ethernet port on the
ONT using an Ethernet cable.
2 Open a Web browser and enter the IP address of the ONT in the Address bar: http://192.168.4.254
↵
The login screen appears, as shown in Figure
Figure 5-5 Login screen
3 Type a User name and Password in the login screen, and click on OK .
Note — The HTTP interface requires a specific username and password. Contact your Alcatel-Lucent technical support representative for username and password information.
The Web-Management System window opens; see Figure
.
4 STOP. This procedure is complete.
Procedure 5-2 To disconnect from the HTTP interface
1 Close any open window.
2 Disconnect the computer or laptop from the first Ethernet port.
3 STOP. This procedure is complete.
5-12 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedures using CLI interface
The CLI interface is accessible in two ways:
• craft port—The CLI interface is accessible through a craft port, which is provided by some outdoor ONT models. You connect to the craft port with an RS-232
DB-9 connector, using a VT100 terminal or PC terminal emulation software set at 9600 Baud, 8 bits, no parity.
• Ethernet over LAN—The CLI interface is accessible through the first Ethernet port on an indoor ONT using a computer or laptop with Telnet software.
The following procedures provide the steps to access and to disconnect from the CLI interface using a craft port, or the first Ethernet port.
Procedure 5-3 To access the CLI interface using a craft port
1 Connect a laptop via serial cable to the RS-232 connector on the ONT.
2 Configure the communications software to the following settings:
• bits/second = 9600
• data bits = 8
• parity = None (N)
• stop bits = 1
• terminal emulation = VT100
3 Log in to a craft session: login: login password: password where login is the username for the ONT password is the password for the ONT
Note — The CLI interface requires a specific username and password.
Contact your Alcatel-Lucent technical representative for login and password information.
The
appears.
4 STOP. This procedure is complete.
Procedure 5-4 To access the CLI interface using the first Ethernet port
1 Connect a computer or laptop to the first Ethernet port on the ONT using an
Ethernet cable.
2 Configure the IP address on the laptop Ethernet port to 192.168.4.1.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-13
5 — ONT management using an ONT interface
3 Perform one of the following: a If the ONT is not ranged, start a Telnet session and Telnet to 192.168.4.254.
telnet 192.168.4.254
↵
Note — The 192.168.4.254 IP address remains open until the ONT has been ranged. After the ONT has been ranged, the ONT no longer accesses this IP address. b If the ONT is ranged, start a Telnet session using the IP address of the ONT.
For example: telnet 192.168.3.10
↵
4 Log in to a Telnet session: login: login password: password where login is the username for the ONT password is the password for the ONT
Note — The CLI interface requires a specific username and password.
Contact your Alcatel-Lucent technical support representative for login and password information.
The
appears.
5 STOP. This procedure is complete.
Procedure 5-5 To disconnect from the CLI interface
1 Choose option 9, Logout , from the main menu.
2 Perform one of the following: a If you are connected to the CLI interface through a craft port, disconnect the serial cable from the RS-232 connector.
b If you are connected to the CLI interface through the first Ethernet port, disconnect the Ethernet cable from the first Ethernet port.
3 STOP. This procedure is complete.
5-14 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure using HTTP interface for Package C ONTs
Package C ONTs support limited configuration using a web-based GUI. The ONT must support an HTTP server, and the computer must have a supported HTTP client
(Web browser).
Note — Contact your Alcatel-Lucent technical support representative for a list of supported Web browsers.
The following procedures provide the steps to access the HTTP interface.
Procedure 5-6 Login to web-based GUI
1 Open a web browser and enter the IP address of the ONT in the address bar.
The login window appears.
The default gateway IP address is http://192.168.50.101. You can also obtain the
IP address using DHCP after connecting your PC to the layer 3 UNI.
2 Enter your username and password in the Login window.
The default username is root while the default password is admin.
Note — If you forget the current username and password, press the reset button for 5 s and the default values for the username and password will be recovered upon start up.
3 Click OK.
4 STOP. This procedure is complete.
Procedures using CLI interface for Package C ONTs
The CLI interface for Package C ONTs is accessible in two ways:
• craft port—The CLI interface is accessible through a craft port, which is provided by some ONT models. You connect to the craft port with an RS-232 DB-9 connector, using a VT100 terminal or PC terminal emulation software set at 9600
Baud, 8 bits, no parity.
• Ethernet over LAN—The CLI interface is accessible through an Ethernet port on an ONT using a computer or laptop with Telnet software.
The following procedures provide the steps to access and to disconnect from the CLI interface using a craft port, or an Ethernet port.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-15
5 — ONT management using an ONT interface
Procedure 5-7 To access the CLI interface using a craft port
1 Connect a laptop via serial cable to the RS-232 connector on the ONT.
2 Configure the communications software to the following settings:
• bits/second = 9600
• data bits = 8
• parity = None (N)
• stop bits = 1
• terminal emulation = VT100
3 Log in to a craft session:
<L>ogin
User Name: CRAFTSPERSON
Password: ALC#FGU where
User Name is the username for the ONT
Password is the password for the ONT
The
4 STOP. This procedure is complete.
Procedure 5-8 To access the CLI interface using an Ethernet port
1 Connect a computer or laptop to an Ethernet port on the ONT using an Ethernet cable.
2 Press the Reset button on the ONT. The ONT reboots with an enabled Telnet server.
3 Start a Telnet session and Telnet to the ONT at 192.168.1.251.
4 Configure the IP address on the laptop Ethernet port to 192.168.1.x. For example,
192.168.1.100.
5-16 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
5 Perform one of the following: a To connect the ONT using an Ethernet port and cable to a computer or laptop, start a Telnet session by typing telnet 192.168.1.x
↵
Note — Any three digits can supply the last segment of the 192.168.1.x
IP address. For example, 192.168.1.100 is a valid IP address. b To connect the computer or laptop to the ONT using a Telnet client, start a
Telnet session by typing telnet 192.168.1.251
↵
Note — NetTerm is the recommended Telnet client.
6 Log in to a Telnet session:
<L>ogin
User Name: CRAFTSPERSON
Password: ALC#FGU where
User Name is the username for the ONT
Password is the password for the ONT
The
7 STOP. This procedure is complete.
Procedure 5-9 To disconnect from the CLI interface
1 Type X or x for Exit
at any time during the session.
2 Perform one of the following: a If you are connected to the CLI interface through a craft port, disconnect the serial cable from the RS-232 connector.
b If you are connected to the CLI interface through an Ethernet port, disconnect the Ethernet cable from the Ethernet port.
3 STOP. This procedure is complete.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-17
5 — ONT management using an ONT interface
5.5
Retrieving product information for an ONT
Product information about an ONT includes the vendor name, firmware, type of
ONT (mnemonic only), and serial number.
This section shows you how to retrieve product information for an ONT.
Prerequisites
The prerequisites are:
• The user access level of the ONT is read-write.
• The steps to access the interface are completed.
• See Procedure
5-1 for HTTP interface using the first Ethernet port.
• See Procedure
5-4 for CLI interface using the first Ethernet port.
• See Procedure
5-6 for HTTP interface for Package C ONTs
Procedures using HTTP interface
The following procedure provides the steps to retrieve product information using the
HTTP interface.
Procedure 5-10 To retrieve product information for an ONT
1 From the Web-Management System window, click on the Product Information tab, as shown in Figure
Figure 5-6 Main options in the Web-Management System window
The Product Information window opens with the product information for the
ONT, as shown in Figure
5-18 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Figure 5-7 Product Information window where
Vendor name is the name of the vendor who built the ONT
Firmware is the software version that is active on the ONT
Type of ONT is the ONT mnemonic
Serial Number of ONT is the serial number that is hard-coded in the ONT
Note 1 — The software load number (FExxxxx) is available from the appropriate ONT Customer Release Notes.
Note 2 — See the appropriate ONT Customer Release Notes for additional information about the ONT.
2 Click on the Refresh button to refresh the contents of the window.
3 STOP. This procedure is complete.
Procedures using CLI interface
The following procedure provides the steps to retrieve the product information for an
ONT using the CLI interface, including firmware version, ONT type, and serial number. The vendor name of the ONT is not available using the CLI interface.
Procedure 5-11 To retrieve product information for an ONT
1 Choose option 8, More options
. The
appears.
2 To retrieve firmware version: i Choose 1, Retrieve firmware version , from the secondary menu.
The active and passive software versions appear. For example:
Active software: 3FEDEFAULT000z
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-19
5 — ONT management using an ONT interface
Passive software: 3FEDEFAULT000x where
Active software is the software that is running on the ONT
Passive software is the software that is in passive mode on the ONT ii Press ↵ to continue.
3 To retrieve the ONT type: i Choose option 4, Retrieve ONT type , from the secondary menu.
The ONT mnemonic appears. For example:
ONT type: I040GM
Type enter key to continue...
ii Press ↵ to continue.
4 To retrieve the serial number of ONT: i Choose option 5, Retrieve serial number , from the secondary menu.
The serial number of the ONT appears. For example:
ONT serial number: ALCLA0AD1A3F
Type enter key to continue...
ii Press ↵ to continue.
5 Choose option 11, Return to main menu , to return to the main menu.
6 STOP. This procedure is complete.
Procedures using HTTP interface for Package C ONT
The following procedure provides the steps to retrieve the product information for an
ONT using the HTTP interface, including ONT type, software version and serial number. The vendor name of the ONT is not available using the HTTP interface.
Procedure 5-12 To retrieve product information for an ONT
1 Select the Device Info option from the ONT Admin section of the navigation tree in the GPON ONT window.
The Device info window appears; see Figure 5-8
.
5-20 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Figure 5-8 Device info window
Table 5-5 describes the fields in the Device info window.
Table 5-5 Device info parameters
Field
Current Time
Type of ONT
Serial Number
Software Version
Received PON power
Ranging state
Download progress
PON alarm
Video alarm
Eth state
Description
Time when the information was collected
Sequence of characters identifying the ONT type
Serial number unique to the ONT
Current version of the software
Indicates whether ONT is receiving power from PON
Indicates the operational mode of the ONT
Status of any current upgrade download events
Status of any current PON alarms
Status of any current video alarms
Current status, either up or down, for each Ethernet link
2 STOP. This procedure is complete.
Procedures using CLI interface for Package C ONTs
Not applicable.
Procedures using butt set
Not applicable.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-21
5 — ONT management using an ONT interface
5.6
Checking ONT status
ONT states indicate the status of an ONT. An ONT state is an operational condition that exists on the ONT, such as the ONT is ranged. Some ONT states, such as loss of signal, generate an alarm that reports the event at the P-OLT. More than one ONT state can be active at the same time.
Table
5-6 describes the ONT states in alphabetical order. For alarm-generating states, Table 5-6
also identifies the alarm that is raised. See the OLT operations and maintenance documentation for information about the alarm, and isolating or resolving the fault condition indicated by the alarm.
Table 5-6 ONT states
ONT state
BATTERY_NOT_PROV
DATAACTIVITY
EQUIPMENT_POWERED
EQPT_FAILURE
IPTV_JOINED
IPTV_NOT_PROVISIONED
LANLOS
LINK_MISMATCH
LOSS_OF_FRAME
LOSS_OF_GEM
LOSS_OF_MULTIFRAME
LOSS_OF_SIGNAL
LOW_BATTERY
MISSING_BATTERY
MOCA_ACTIVITY
(1 of 3)
Description
The battery on the ONT is not provisioned to be used on the ONT.
Ethernet packets are being received on the
ONT.
The ONT has power.
The ONT hardware failed.
An IP multicast stream is joined.
The in-band IGMP multicast video is not provisioned.
There is a loss of signal on an Ethernet port interface (no carrier).
The LANLOS alarm is raised, and is the OMCI
LAN-LOS alarm on the PPTP Ethernet UNI
Managed Entity. The alarm is directly related to the LAN Link LED on the ONT.
Not supported
The signal between the P-OLT and ONT loses framing.
The data signal between the P-OLT and ONT consists of packets of information that is put in frames to encapsulate the data and make it distinguishable. A loss of frame might be caused by timing error or data corruption.
There is loss of GEM/ATM channel delineation of the ONT.
Contact your Alcatel-Lucent technical support representative for information.
The signal to the ONT is lost.
The UPS battery charge is low.
The UPS battery is provisioned, but is missing.
Packets are received over the MoCA link.
Alarm
—
—
—
—
—
—
LANLOS
MIS
LOF
LCD
—
LOS
BATTLOW
BATTMISS
—
5-22 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
ONT state
MOCA_LOSS_OF_LINK
MOCA_NOT_REG
MSG_ERROR_MSG
OMCC_NOT_ASSIGNED
OMCI_ENV1
OMCI_ENV2
ON_BATTERY
ONT_DEACTIVATE
ONT_DISABLE
ONT_RANGED
PHY_EQPT_ERROR_IN
PHYSICALEQUIPMENTERROR
PHYSICAL_LAYER_DISABLED
PHYSICAL_LAYER_INACTIVE
PON_HIGH
PON_LOSS
PON-LOW
Description
There is a loss of link on the MoCA physical interface between the ONT and the broadband home router.
There is a loss of link on the MoCA physical interface between the ONT and the broadband home router
There is a physical layer error message from the ONT.
The ONT fails to respond to OMCI message requests, or loss of communication
State corresponds to a customer installed device. The source of the ENV1 alarm, which is the customer device, is at fault and must be addressed by the customer.
State corresponds to a customer installed device. The source of the alarm, which is the customer device, is at fault and must be addressed by the customer.
There is loss of external power to ONT, or the ONT is on battery backup, or the power supply failed.
There is a deactivate failure of the ONT.
The ONT has been autonomously disabled because of misbehaving transmissions.
The ONTDISABLED alarm is a defense alarm so that the ONT does not affect the entire
PON.
The ONT is ranged.
There is physical equipment error on ONT.
There is physical equipment error on ONT.
Contact your Alcatel-Lucent technical support representative for information.
Contact your Alcatel-Lucent technical support representative for information.
The 1490 nm optical signal level is too high.
The ONT polls this signal level once a second, and indicates if the alarm condition is present.
The P-OLT is not receiving transmissions from the PON.
The state normally results from a fiber pulled from the PON interface, or the feed into a splitter.
State indicating if the 1490 nm optical signal level is too low
The ONT polls this signal level once a second, and indicates whether the alarm condition is present.
Alarm
MOCALOL
MOCALOL
MEM
OMCICOMM
ENV1
ENV2
ACFAIL (was PWR)
DF
ONTDISABLED
—
PEE
PEE
—
—
LEVELHI
PONLOS
LEVELLO
(2 of 3)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-23
5 — ONT management using an ONT interface
5-24
ONT state
RDI
REPLACE_BATTERY
SIGNAL_DEGRADED
SIGNAL_FAILED
STARTUP_FAILURE
SW_DLD_DONE
SW_DLD_FAIL
SW_DLD_IDLE
SW_DLD_IP
SW_DLD_START
TRANSMITTER_FAILURE
VIDEO_HIGH
VIDEO_LOSS
VIDEO_LOW
VIDEO_PROVISIONED
Description
There is a remote defect indication from the
ONT.
The OLT transmission was received with errors at the ONT. Check the receive signal at the ONT.
The UPS battery is provisioned and present, but cannot recharge.
The signal degraded for the ONT (BER threshold exceeded).
The signal failed from the ONT (BER threshold exceeded).
You can check the signal quality of the line from the ONT.
There is a startup failure in the ranging of the ONT.
The software download to the ONT is
The software download to the ONT failed
.
The SWDLFAIL alarm is raised if the download fails.
A software download to the ONT is idle (1) .
A software download is in progress from the
OLT to the ONT
.
A software download to the ONT is initiated
.
The SWDLIP alarm is raised when the download is initiated, and clears when there is no pending file-transfer activity or when the download has completed, successfully or not.
There is a transmitter failure on an OLT port.
The RF video signal being generated out of the ONT has a high power level.
There is loss of signal on the RF video overlay port interface.
The VIDEOLOS alarm is raised and is the
OMCI video loss of signal alarm on the PPTP
Video ANI Managed Entity. This indicates that the 1550 nm video overlay optical signal level has dropped.
The ONT polls this once signal level once a second and indicates if the alarm condition is present or if the alarm condition is cleared.
The RF video signal being generated out of the ONT has a low power level.
The 1550 nm video overlay is provisioned.
Alarm
RDI
BATTFAIL
SD
SF
SUF
—
SWDLFAIL
—
—
SWDLIP
TXFAIL
RFOUTHIGH
VIDEOLOS
RFOUTLOW
—
(3 of 3)
Note
(1) See Procedure
to monitor a software download from the P-OLT to the ONT.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
This section shows you how to retrieve ONT states to check the status of an ONT.
Prerequisites
The prerequisites are:
• The user access level of the ONT is read-write.
• The ONT is connected to the PON, and is ranged.
• The steps to access the interface are completed.
• See Procedure
5-1 for HTTP interface using the first Ethernet port.
• See Procedure
5-4 for CLI interface using the first Ethernet port.
Procedures using HTTP interface
The following procedure provides the steps to check ONT status using the HTTP interface.
Procedure 5-13 To check ONT status
1 From the Web-Management System window, click on the States Management tab, as shown in Figure
Figure 5-9 Main options in the Web-Management System window
The ONT status window opens with the ONT states and their current status, as shown in Figure
.
Figure 5-10 ONT status window where
ONT state is a mnemonic that represents a possible condition on the ONT; see Table
alphabetical listing and description of the ONT states
Status is the operational state of the condition, where a red button means that the condition is present, that is active, on the ONT, and a green button means that the condition is not present, that is inactive, on the ONT
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-25
5 — ONT management using an ONT interface
2 Use the scroll bar in the ONT status window to scroll up and down the list of ONT states.
3 Click on the Refresh button to refresh the contents of the window.
4 STOP. This procedure is complete.
Procedures using CLI interface
The following procedure provides the steps to check ONT status using the CLI interface.
Procedure 5-14 To check ONT status
1 Choose option 8, More options
. The
appears.
2 Choose option 2, Retrieve ONT states , from the secondary menu.
The list of ONT states appear with their current status shown as either active or inactive. For example:
ONT_SW_FAULT -- INACTIVE
OMCI_ENV1 -- INACTIVE
OMCI_ENV2 -- INACTIVE
NO_ALARM -- INACTIVE press enter key to continue...
where the ONT state is shown as a mnemonic that represents a possible condition on the ONT; see
Table
for an alphabetical listing and description of the ONT states the operational state of the condition is either active, which means that the condition is present on the ONT, or inactive, which means that the condition is not present on the ONT
3 Press ↵ to continue.
4 Choose option 11, Return to main menu , to return to main menu.
5 STOP. This procedure is complete.
Procedures using HTTP interface for Package C ONTs
Not applicable.
Procedures using CLI interface for Package C ONTs
Not applicable.
5-26 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5.7
5 — ONT management using an ONT interface
Procedures using butt set
Not applicable.
Retrieving uptime of an ONT
The uptime of an ONT is the length of time that the ONT has run without resetting.
The uptime time can be used to detect a power failure.
This section shows you how to retrieve the uptime of an ONT.
Prerequisites
The prerequisites are:
• The user access level of the ONT is read-write.
• The steps to access the interface are completed.
• See Procedure
5-1 for HTTP interface using the first Ethernet port.
• See Procedure
5-4 for CLI interface using the first Ethernet port.
Procedures using HTTP interface
The following procedure provides the steps to view the uptime of an ONT using the
HTTP interface.
Procedure 5-15 To view the uptime of an ONT
1 From the Web-Management System window, click on the States Management tab, as shown in Figure
.
Figure 5-11 Main options in the Web-Management System window
The ONT status window opens with the ONT states and their current status, as shown in Figure
.
2 Click on the Uptime tab in the window. The Uptime of ONT windows opens with the current uptime, as shown in Figure
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-27
5 — ONT management using an ONT interface
Figure 5-12 Uptime of ONT window
5-28 where Uptime of ONT represents the length of time since the ONT was last powered on or reset, in the format hh:mm:ss
3 Click on the Refresh button to refresh the contents of the window.
4 STOP. This procedure is complete.
Procedures using CLI interface
The following procedure provides the steps to view the uptime of an ONT using the
CLI interface.
Procedure 5-16 To view the uptime of an ONT
1 Choose option 8, More options
. The
appears.
2 Choose option 3, Retrieve uptime , from the secondary menu.
The uptime of the ONT appears. For example:
ONT uptime is: 01:22:44 up 1:23 press enter key to continue...
where ONT uptime represents the length of time since the ONT was last powered on or reset, in the format hh:mm:ss and hh:mm, where hh:mm is rounded to the nearest minute
3 Press ↵ to continue.
4 Choose option 11, Return to main menu , to return to main menu.
5 STOP. This procedure is complete.
Procedures using HTTP interface for Package C ONTs
Not applicable.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5.8
5 — ONT management using an ONT interface
Procedures using CLI interface for Package C ONTs
Not applicable.
Procedures using butt set
Not applicable.
Retrieving RSSI
The RSSI is the recorded measurement of the ONT receive optical signal at 1490 nm in dBm. This feature is available for RSSI-capable ONTs only.
This section shows you how to retrieve the RSSI measurement for an ONT.
Prerequisites
The prerequisites are:
• The user access level of the ONT is read only or read-write.
• The ONT is RSSI capable.
• The steps to access the interface are completed.
• See Procedure
5-1 for HTTP interface using the first Ethernet port.
• See Procedure
5-4 for CLI interface using the first Ethernet port.
Procedures using HTTP interface
The following procedure provides the steps to view the RSSI measurement for an
ONT using the HTTP interface.
Procedure 5-17 To view RSSI
1 From the Web-Management System window, click on the States Management tab, as shown in Figure
.
Figure 5-13 Main options in the Web-Management System window
The ONT status window opens with the ONT states and their current status, as shown in Figure
.
2 Click on the RSSI tab. The RSSI window opens with the current RSSI measurement, as shown in Figure
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-29
5 — ONT management using an ONT interface
Figure 5-14 RSSI window where receive RSSI is the recorded measurement of the ONT receive optical signal level at 1490 nm in dBm. The RSSI range is − 65.536 dBm to +65.538 dBm where − 65.536 means unknown and
+65.538 means unsupported.The receive RSSI is zero when the ONT is not connected to the GPON, or there is loss of connection with the GPON.
Note — The absolute accuracy of the optical signal reading is
+ or − 3.0 dB. This should be taken into account when reading values.
3 Click on the Refresh button to refresh the contents of the window.
4 STOP. This procedure is complete.
Procedures using CLI interface
The following procedure provides the steps to view the RSSI measurement for an
ONT using the CLI interface.
5-30 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure 5-18 To view RSSI
1 Choose option 7, Retrieve optical level
. The current RSSI measurement appears. For example: ponOpticalSignalLevel = -40.727268 dBm where ponOpticalSignalLevel (receive RSSI) is the recorded measurement of the ONT receive optical signal level at 1490 nm in dBm. The range is − 65.536 dBm to +65.538 dBm, where − 65.536 means unknown and +65.538 means unsupported. The receive RSSI is zero when the ONT is not connected to the GPON, or there is loss of connection with the GPON.
Note — The absolute accuracy of the optical signal reading is
+ or − 3.0 dB. This should be taken into account when reading values.
2 STOP. This procedure is complete.
5.9
Procedures using HTTP interface for Package C ONTs
Not applicable.
Procedures using CLI interface for Package C ONTs
Not applicable.
Procedures using butt set
Not applicable.
Checking status of LEDs
The ONT LEDs provide information related to the connectivity between the ONT and the LT card. The LEDs can indicate a variety of issues, such as:
• ONT not powered
• equipment failed or not ranged
• higher-level problem in management software
Table
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-31
5 — ONT management using an ONT interface
LED
EQPT
PON
IPTV
RFTV
POTS
MGMT
NTWK
DATA
VID
FAIL
BTRY
MOCA
PWR_LED
ALM_LED
WAN_LED
Table 5-7 ONT LEDs
Description
Battery power is available.
The PON is communicating with the ONT.
The IPTV service is provisioned.
The RF video is provisioned.
A phone is off-hook.
Communication is established between the P-OLT and ONT through OMCI.
The 1490 nm data path is available.
The data (Ethernet or MoCA) link is active, or if the data link is not active or not provisioned.
The video signal is above or below acceptable level or not provisioned.
The equipment is 100% operational, or the equipment has failure, or is not ranged or synchronized.
The status of the battery
The activity on the MoCA link
There is power to the ONT
The operational state of the ONT
The ONT is connected properly to the PON.
Note — Table
lists all possible LEDs on an ONT. For a list of
LEDs specific to a particular ONT, see the unit data sheet for that
ONT.
This section shows you how to check the current and persistent state of LEDs.
Prerequisites
The prerequisites are:
• The user access level of the ONT is read-write.
• The steps to access the interface are completed.
• See Procedure
5-1 for HTTP interface using the first Ethernet port.
• See Procedure
5-4 for CLI interface using the first Ethernet port.
Procedures using HTTP interface
The following procedure provides the steps to check the status of the ONT LEDs using the HTTP interface.
5-32 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure 5-19 To check the status of LEDs
1 From the Web-Management System window, click on the States Management tab, as shown in Figure
.
Figure 5-15 Main options in Web-Management system window
The ONT status window opens with the ONT states and their current status, as shown in Figure
.
2 Click on the LED tab. The ONT LEDs window appears with the LEDS, their color, current LED state, and persistent LED state shown.
Figure 5-16 ONT LEDs where
LED is the mnemonic for an LED on the ONT. Each LED represents a condition or activity on the
ONT, such as the condition of the battery or the activity of a data link; see Table
explanation of each LED.
COLOR is the color of the LED. The color of the LED represents the status of a condition or activity on the ONT, such as red for failing battery or green for activity on the data link; see the
ONT-specific unit data sheet for the meaning of a color for a specific LED and ONT type.
CURSTATE represents the current LED state, where OFF means the LED is not lit, ON means that the LED is lit and the color is solid.
PERSTATE represents the persistent state of the LED, where OFF means that the LED was not lit, and ON means that the LED was lit and the color was solid.
3 Use the scroll bar in the ONT LEDs window to scroll up and down the list of LEDs.
4 Click on the Refresh button to refresh the contents of the window.
5 STOP. This procedure is complete.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-33
5 — ONT management using an ONT interface
Procedures using CLI interface
The following procedure provides the steps to check the status of the ONT LEDs using the CLI interface.
Procedure 5-20 To check the status of LEDs
1 Choose option 8, More options
. The
appears.
2 Choose option 6, Retrieve ONT LED status , from the secondary menu.
The ONT LEDs appear with their color, current LED state, and previous LED state shown. For example:
In print_led_states
LED COLOR CURSTATE
===================================
EQPT
PON
IPTV
RFTV
POTS
MGMT
NTWK
DATA
VID
FAIL
BTRY
MOCA
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
GREEN
GREEN
GREEN
GREEN
OFF
OFF
OFF
OFF
PWR_LED
ALM_LED
GREEN
GREEN
ON
OFF
WAN_LED RED ON press enter key to continue...
PRESTATE
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF where
LED is the mnemonic for an LED on the ONT. Each LED represents a condition or activity on the
ONT, such as the condition of the battery or the activity of a data link; see Table
explanation of each LED.
COLOR is the color of the LED. The color of the LED represents the status of a condition or activity on the ONT, such as red for failing battery or green for activity on the data link; see ONT-specific unit data sheet for the meaning of a color for a specific LED and ONT type.
CURSTATE represents the current LED state, where OFF means the LED is not lit, ON means that the LED is lit and the color is solid.
PRESTATE represents the previous state of the LED, where OFF means that the LED was not lit, and ON means that the LED was lit and the color was solid.
3 Press ↵ to continue.
4 Choose option 11, Return to main menu , to return to main menu.
5 STOP. This procedure is complete.
5-34
Procedures using HTTP interface for Package C ONTs
Not applicable.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5.10
5 — ONT management using an ONT interface
Procedures using CLI interface for Package C ONTs
Not applicable.
Procedures using butt set
Not applicable.
Checking ranging state of an ONT
The ranging state indicates the operational mode of the ONT as per ITU 984.3.
Table
5-8 describes the possible ranging states for an ONT.
Table 5-8 Ranging states of an ONT
Ranging state
Initial state
Standby state
Serial number state
Ranging state
Operation state
Popup state
Emergency stop state
Description
The ONT is on, but is not connected to the GPON.
The ONT is waiting for network parameters, such as a preassigned equalization delay, or the number of preamble bytes to use in the upstream direction.
The ONT is waiting for a serial number request. When the request is received, the ONT registers.
The ONT is waiting for a ranging request. Based on the round-trip delay (RTD) time, the P-OLT calculates the ONT’s equalization delay.
The ONT is ranged. In the operation state, the upstream frames will be synchronized together between the ONTs on the PON.
Also, the upstream transmissions will arrive separately, each one in its correct location within the frame. In this state, the ONT can be halted by the P-OLT, to implement serial number or ranging processes with other ONTs.
The ONT enters the popup state from the operation state after detecting an alarm, such as loss of signal (LOS) or loss of frame
(LOF). In the pop-up state, the ONT stops transmitting in the upstream direction.
The ONT is in an emergency stop state, and does not receive and transmit data until the P-OLT enables it.
This section shows you how to retrieve the ranging state of an ONT.
Prerequisites
The prerequisites are:
• The user access level of the ONT is read only or read-write.
• The steps to access the interface are completed.
• See Procedure
5-1 for HTTP interface using the first Ethernet port.
• See Procedure
5-4 for CLI interface using the first Ethernet port.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-35
5 — ONT management using an ONT interface
Procedures using HTTP interface
The following procedure provides the steps to check the ranging state of an ONT using the HTTP interface.
Procedure 5-21 To check the ranging state of an ONT
1 Ensure that the ONT is connected to the GPON.
2 From the Web-Management System window, click on the States Management tab, as shown in Figure
.
Figure 5-17 Main options in the Web-Management System window
The ONT status window opens with the ONT states and their current status, as shown in Figure
.
3 Click on the Ranging tab. The Ranging State window opens with the current ranging state, as shown in Figure
Figure 5-18 Ranging State window
5-36 where the ranging states are described in Table
4 Click on the Refresh button to refresh the contents of the window.
5 STOP. This procedure is complete.
Procedures using CLI interface
The following procedure provides the steps to check the ranging state of an ONT using the CLI interface.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure 5-22 To check the ranging state of an ONT
1 Ensure that the ONT is connected to the GPON.
2 Choose option 6, Retrieve ranging state , from the
The current ranging state of the ONT appears. For example:
Ranging State = Initial State (Auto-Disable State = Normal State) where the ranging states are described in Table
3 Press ↵ to continue.
4 STOP. This procedure is complete.
5.11
Procedures using HTTP interface for Package C ONTs
Not applicable.
Procedures using CLI interface for Package C ONTs
Not applicable.
Procedures using butt set
Not applicable.
Monitoring software download to an ONT
Software downloads are updates or upgrades to software features of an ONT.
Software updates and upgrades are performed at the CO, and downloaded from the
P-OLT to the ONT.
Table
5-9 identifies the software download states.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-37
5 — ONT management using an ONT interface
Download state
Idle
Downloading
Writing to flash
Complete
Table 5-9 Software download states
Description
There is no download activity.
Software is being downloaded from the P-OLT to the ONT.
Software updates are being written to memory.
Software download is complete.
Note — The ONT changes from one operational state to another as the software download progresses, as follows:
• SW_DLD_IDLE, when there is no software download activity
• SW_DLD_START, when the software download is initiated
• SW_DLD_IP, when the software download is in progress
• SW_DLD_DONE, when the software download is complete
• SW_DLD_FAIL, when the software download failed
See section
for more information about checking the operational state of an ONT.
This section shows you how to check the status of a software download.
Prerequisites
The prerequisites are:
• The user access level of the ONT is read-write.
• The ONT is connected to the GPON.
• The steps to access the interface are completed.
• See Procedure
5-1 for HTTP interface using the first Ethernet port.
• See Procedure
5-4 for CLI interface using the first Ethernet port.
Procedures using HTTP interface
The following procedure provides the steps to check the status of the software download from the P-OLT to the ONT using the HTTP interface.
5-38 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure 5-23 To check status of software download
1 From the Web-Management System window, click on the ONT management tab, as shown in Figure
Figure 5-19 Main options in the Web-Management System window
The ONT management window opens with the current download state, as shown in Figure
.
Figure 5-20 Download state window where the download states are described in Table
2 Click on the Refresh button to refresh the contents of the window.
3 STOP. This procedure is complete.
Procedures using CLI interface
The following procedure provides the steps to check the status of the software download from the P-OLT to the ONT using the CLI interface.
Procedure 5-24 To check the status of software download
1 Choose 8, More options
. The
appears.
2 Choose 7, Retrieve download progress , from the secondary menu.
The current state of the download appears. for example:
Software Download: State = Complete press enter key to continue...
where the download states are described in Table
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-39
5 — ONT management using an ONT interface
3 Press ↵ to continue.
4 Choose option 11, Return to main menu , to return to main menu.
5 STOP. This procedure is complete.
5.12
Procedures using HTTP interface for Package C ONTs
Not applicable.
Procedures using CLI interface for Package C ONTs
Not applicable.
Procedures using butt set
Not applicable.
Rebooting an ONT
The ONT may require rebooting from time to time to recover from certain events.
Two forms of reboot are available:
• Force reset, to reboot immediately regardless of the download state of the ONT
• Graceful reset, to reboot after a software download is complete
This section shows you how to reboot an ONT.
Prerequisites
The prerequisites are:
• The user access level of the ONT is read-write.
• The steps to access the interface are completed.
• See Procedure
5-1 for HTTP interface using the first the Ethernet port.
• See Procedure
5-4 for CLI interface using the first Ethernet port.
• See Procedure
5-6 for HTTP interface for Package C ONTs
• See Procedure
5-8 for Package C ONT CLI interface using an Ethernet port.
Procedures using HTTP interface
The following procedure provides the steps to reboot an ONT using the HTTP interface.
5-40 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure 5-25 To reboot an ONT
1 From the Web-Management System window, click on the ONT Management tab, as shown in Figure
Figure 5-21 Main options in the Web-Management System window
The Download state window opens with the current download state, as shown in
Figure
.
Figure 5-22 Download state window where the download states are described in Table
2 Check if a software download is in progress. Click on the Refresh button to refresh the Download state , as required.
3 Click on the Reset tab. The Reset window opens, as shown in Figure
.
Figure 5-23 Reset window
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-41
5 — ONT management using an ONT interface
4 Click on one of the following buttons to reboot the ONT:
• Force reset —to reboot the ONT immediately regardless of the download state of the ONT
• Graceful reset —to reboot after an ongoing software download is complete
The reset ONT dialog box opens, as shown in Figure
Figure 5-24 Reset ONT dialog box
5-42
5 Click on the Reset button to reboot the ONT.
The status bar appears a message after the ONT is rebooted successfully.
6 STOP. This procedure is complete.
Procedures using CLI interface
The following procedure provides the steps to reboot an ONT using the CLI interface.
Procedure 5-26 To reboot an ONT
1 Choose option 8, More options
. The
appears.
2 Choose option 7, Reboot an ONT , from the secondary menu.
The current state of the download appears. For example:
Software Download: State = Complete press enter key to continue...
where the download states are described in Table
3 Press ↵ to continue.
4 Choose option 11, Return to main menu , to return to main menu.
5 STOP. This procedure is complete.
Procedures using HTTP interface for Package C ONT
The following procedure provides the steps to reboot an ONT using the HTTP interface for Package C ONTs.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure 5-27 To reboot a Package C ONT
1 Select the Reboot option from the ONT Admin section of the navigation tree in the
GPON ONT window.
The Reboot window appears; see Figure
.
Figure 5-25 Reboot window
2 Click Reset to reboot the system.
3 STOP. This procedure is complete.
Procedures using CLI interface for Package C ONTs
The following procedure provides the steps to reboot an ONT using the CLI interface provided with Package C ONTs.
Procedure 5-28 To reboot a Package C ONT
1 Type R or r for Reboot from the
SLID menu at any time during the session.
2 STOP. This procedure is complete.
5.13
Procedures using butt set
Not applicable.
Tracing OMCI and protocol traffic
Tracing is a logging of traffic to detect or resolve networking problems. Trace logs are normally provided to support staff for troubleshooting. You can trace OMCI,
ARP, DHCP, or IGMP protocol traffic.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-43
5 — ONT management using an ONT interface
From the HTTP interface, you can collect trace statements in a log file that you can view on-line as follows:
1 Specify the traffic to log, and enable tracing.
2 Specify the action for the system to take when the trace log is full.
3 Disable tracing.
4 Specify the trace log to view.
From the CLI interface, you can view trace statements in real time, or collect trace statements in a log file that you can copy to a TFTP server. To view trace statements in real time from the CLI interface:
1 Specify the traffic that you want to view in real time.
2 Enable real-time tracing.
3 Press
↵
when you are finished.
To trace in logging mode from the CLI interface:
1 Specify the traffic that you want to log.
2 Enable tracing.
3 Specify the action to take by the system when the trace log is full.
4 Disable tracing.
5 Copy the trace log to a TFTP server.
Note — As tracing affects the performance of an ONT, ensure that you disable tracing when you are finished.
This section shows you how to:
• enable tracing
• disable tracing
• retrieve the trace log
Prerequisites
The prerequisites are:
• The user access level of the ONT is read-write.
• The ONT is connected to the GPON.
• The ONT is activated with its services.
• The steps to access the interface are completed.
• See Procedure
5-1 for HTTP interface using the first Ethernet port.
• See Procedure
5-4 for CLI interface using the first Ethernet port.
• See Procedure
5-6 for HTTP interface for Package C ONTs
5-44 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedures using HTTP interface
The following procedures provide the steps to enable tracing, and to retrieve trace logs for an ONT using the HTTP interface.
Procedure 5-29 To enable tracing
1 From the Web-Management System window, click on the Trace Management tab, as shown in Figure
Figure 5-26 Main options in Web-Management system window
The Trace Management window opens with the current trace management settings, as shown in Figure
Figure 5-27 Trace Management window
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-45
5 — ONT management using an ONT interface
2 Enable or disable one or more of the following radio buttons, and click on the
Apply button to enable or disable tracing:
• OMCI —Tracing OMCI traffic allows you to review the transfer of data between the P-OLT and the ONT, such as service provisioning data, anti-spoofing filters, and leased IP addresses, and to test the physical layer of the GPON from the
P-OLT to the ONT. The OMCI trace can help to pinpoint faults in the fiber link during or after installation.
• ARP —Tracing ARP protocol traffic allows you to review ARP dialog between the
ONT and host devices including ARP requests and responses for MAC addresses, and to test the media access level of the network. Traces are displayed in hexadecimal format (see Figure
You can use a product, such as Wireshark, to decode traces.
• DHCP —Tracing DHCP protocol traffic allows you to review DHCP dialog between the ONT and the CPE devices, and between the ONT and the P-OLT to ensure CPE devices are able to request and obtain IP addresses for host devices.
• IGMP —Tracing IGMP traffic allows you to monitor IGMP messages between host devices and the ONT, and between the ONT and the LT to ensure proper IPTV or IP video service to subscribers.
3 Enable one of the following radio buttons to specify the action for the system to take when a log file is full, and click on the Apply button to apply setting:
• Stop logging —create only one log file.
• Append —create a second log file when the first log file is full. The content of this second log file will be appended to the content of the first log file when you view the log files, using Procedure
.
4 STOP. This procedure is complete.
Procedure 5-30 To disable tracing
1 From the Trace Management window, as shown in Figure
, disable one or more of the following radio buttons, and click on the Apply button to disable tracing:
• OMCI
• ARP
• DHCP
• IGMP
2 STOP. This procedure is complete.
5-46 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure 5-31 To retrieve a trace log
1 Ensure that tracing has been disabled; see Procedure
2 From the Trace Management window shown in Figure
, choose a log file from the list of log files to view, and click on the Show button.
Figure 5-28 Trace Management window
Note — The list of log files includes only the traffic that was enabled for tracing in Procedure
A screen displays the trace information in the log file. Figure
ARP log file.
Figure 5-29 Sample ARP log file
Note — The log file is not permanently stored on the ONT, and can be lost after an ONT power cycle or reboot.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-47
5 — ONT management using an ONT interface
3 Click on Exit to return to the Trace Management window.
4 STOP. This procedure is complete.
5-48
Procedures using CLI interface
The following procedures provide the steps to enable tracing in real time or in logging mode using the CLI interface.
Procedure 5-32 To trace in real time or logging mode
This procedure allows you to enable tracing in real time or in logging mode. In real time, trace statements display automatically on the console; in logging mode, trace statements are collected in a trace log that you can copy to a TFTP server for retrieval.
1 Choose option 8, More options
. The
appears.
2 Choose option 9, Enable protocol traces
, from the Secondary menu . The
following menu of options appears:
Please select protocol
===============
1. OMCI
2. DHCP
3. ARP
4. IGMP
5. Logging options
Enter choice :
3 Choose one of the following protocols to trace: a Choose option 1 for OMCI.
Tracing OMCI traffic allows you to review the transfer of data between the
P-OLT and the ONT, such as service provisioning data, anti-spoofing filters, and leased IP addresses, and to test the physical layer of the GPON from the
P-OLT to the ONT. The OMCI trace can help to pinpoint faults in the fiber link during or after installation.
b Choose option 2 for DHCP.
Tracing DHCP protocol traffic allows you to review DHCP dialog between the
ONT and the CPE devices, and between the ONT and the P-OLT to ensure CPE devices are able to request and obtain IP addresses for host devices.
c Choose option 3 for ARP.
Tracing ARP protocol traffic allows you to review ARP dialog between the
ONT and host devices including ARP requests and responses for MAC addresses, and to test the media access level of the network. Traces are displayed in hexadecimal format. For example:
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
-- ARP -ff ff ff ff ff ff 00 e0 b1 7a 00 c0 08 06 00 01
08 00 06 04 00 01 00 e0 b1 7a 00 c0 ac 16 b5 41
00 00 00 00 00 00 ac 16 b5 4e b1 7a 00 c0 77 19
00 00 00 00 00 00 00 00 00 00 00 00
You can use a product, such as Wireshark, to decode traces. d Choose option 4 for IGMP.
Tracing IGMP traffic allows you to monitor IGMP messages between host devices and the ONT, and between the ONT and the LT to ensure proper IPTV or IP video service to subscribers.
After you choose a protocol, the following trace options appear:
Trace options
===============
1. Real-time traces
2. Enable logging
3. Disable logging
Enter choice :
4 Perform one of the following: a To view trace statements in real time: i Choose option 1, trace statements.
Real-time traces.
The system responds by displaying
Press enter key to disable real-time tracing at any time... ii To stop the display of trace statements, press ↵ . The system responds by displaying the
with the message: dbg_logger: disabling this console b To enable logging of trace statements: i Choose option 2, Enable logging . The following message appears: xxxx traces logging enabled
Press enter key to continue...
where xxxx is the selected protocol ii Press ↵ to continue. The
appears.
iii Specify the action for the system to take when log file is full using
Procedure
.
iv Disable tracing, using Procedure
.
v Copy the trace log to a TFTP server, using Procedure
.
5 STOP. This procedure is complete.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-49
5 — ONT management using an ONT interface
Procedure 5-33 To specify logging option
1 Choose option 9, Enable protocol traces
, from the Secondary menu . The
following menu of options appears:
Please select protocol
===============
1. OMCI
2. DHCP
3. ARP
4. IGMP
5. Logging options
Enter choice :
2 Choose option 5, Logging options . The following menu of options appears:
When log file size limit is reached, what do you want to do:
===============
1. Append
2. Stop logging
Enter choice :
3 Choose one of the following actions for the system to take when the log file is full: a Choose option 1, Append , to create a second log file when the first log file is full. The content of this second log file will be appended to the content of the first log file when you view the log files, using Procedure
.
b Choose option 2, Stop logging , to create only one log file.
The following message appears:
Press enter key to continue...
Note — The log file is not permanently stored on the ONT, and can be lost after an ONT is powered off and on, or is reset.
4 Press ↵ to continue. The
appears.
5 STOP. This procedure is complete.
5-50 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure 5-34 To disable tracing in logging mode
Use this procedure to disable tracing in logging mode. You must disable tracing before copying the trace log to a TFTP server.
1 Choose option 9, Enable protocol traces
, from the Secondary menu . The
following menu of options appears:
Please select protocol
===============
1. OMCI
2. DHCP
3. ARP
4. IGMP
5. Logging options
Enter choice :
2 Choose one of the following protocols to disable tracing: a Choose option 1 for OMCI.
b Choose option 2 for DHCP.
c Choose option 3 for ARP.
d Choose option 4 for IGMP.
After you choose a protocol, the following trace options appear:
Trace options
===============
1. Real-time traces
2. Enable logging
3. Disable logging
Enter choice :
3 Choose option 3, Disable logging . The following message appears:
Press enter key to continue...
4 Press ↵ to continue. The
appears.
5 STOP. This procedure is complete.
Procedure 5-35 To copy a trace log to a TFTP server
Use this procedure to copy a trace log to a specified file on a TFTP server. You must specify the trace log, the IP address of the TFTP server, and the file name of the log file on the TFTP server.
1 Ensure tracing has been disabled, using Procedure
2 Choose option 10, Upload traces from the
. The following menu of options appears:
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-51
5 — ONT management using an ONT interface
Please select trace file
===============
1. OMCI
2. DHCP
3. ARP
4. IGMP
Enter choice :
3 Choose the trace log to copy over to the server: a Choose option 1 for OMCI.
b Choose option 2 for DHCP.
c Choose option 3 for ARP.
d Choose option 4 for IGMP.
The following appears:
Enter server IP address:
4 Type the IP address of the TFTP server.
The following appears:
Enter file name on the server:
5 Type the name of the file on the server where the content of trace log is to be copied.
The system copies the trace log into the specified file on the TFTP server.
• If a trace log is not found, the following message appears:
No logs to retrieve
Press enter key to continue...
• If a trace log is found, the following message appears after the copying is complete:
Done
Press enter key to continue...
6 Press ↵ to continue. The
appears.
7 To return to
, choose option 11, Return to main menu .
8 STOP. This procedure is complete.
Procedures using HTTP interface for Package C ONTs
The following procedures provide the steps to enable OMCI and Protocol tracing using the HTTP interface for Package C ONTs.
5-52 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure 5-36 To perform an OMCI trace for a Package C ONT
1 Select the Omci Trace option from the ONT Admin section of the navigation tree in the GPON ONT window.
The Omci Trace window appears; see Figure
.
Figure 5-30 Omci trace window
2 Click Start to initiate an OMCI trace.
3 Perform one of the following tasks to stop an OMCI trace. i Click Stop to end the OMCI trace. ii Click Delete to end the OMCI trace and delete the trace file.
4 STOP. This procedure is complete.
Procedure 5-37 To perform a Protocol trace for a Package C ONT
1 Select the Protocol Trace option from the ONT Admin section of the navigation tree in the GPON ONT window.
The Protocol Trace window appears; see Figure 5-31 .
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-53
5 — ONT management using an ONT interface
Figure 5-31 Protocol Trace window
2 Select a tracing protocol by choosing either ARP, DHCP, or IGMP.
3 Click Start to initiate a protocol trace.
4 If necessary, click Stop to end a protocol trace.
5 Perform one of the following tasks with the tracing file produced by the protocol trace.
i Click Download to save the tracing file. ii Click Delete to delete the tracing file.
6 STOP. This procedure is complete.
5.14
5-54
Procedures using CLI interface for Package C ONTs
Not applicable.
Procedures using butt set
Not applicable.
Activating an ONT using an SLID
The P-OLT is programmed to use the serial number or a SLID to activate a newly polled ONT on the PON with its provisioning data and services. The serial number is hard-coded into the ONT; the SLID is a hexadecimal or alphanumeric string that you enter locally into the ONT to uniquely identify the ONT on the PON.
After the P-OLT polls the PON for new ONTs, the ONT sends its SLID, range, and registration information to the P-OLT. The P-OLT matches the ONT with its provisioning data and services in the P-OLT database, using the serial number or the
SLID. When a database match is found, the P-OLT downloads the provisioning data and services to the ONT, and the ONT and its services are activated.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
To activate an ONT using the serial number, the following is required:
• The ONT must be provisioned at the P-OLT with its serial number, a dummy
SLID, provisioning data, and services.
• The ONT with the corresponding serial number must be installed at the customer site.
• The ONT must be connected to the GPON.
To activate an ONT using the SLID, the following is required:
• The ONT must be provisioned at the P-OLT with a dummy serial number, its
SLID, provisioning data, and services.
• The ONT with any serial number must be installed at the customer site.
• The SLID in the ONT must be cleared locally, if the ONT has a non-default SLID.
• The SLID must be entered locally into the ONT.
• The ONT must be connected to the GPON.
Activation of an ONT can also be initiated by the P-OLT automatically at regular intervals or when one or more formerly registered and active ONTs become inactive.
In both cases, the frequency of the P-OLT polling is programmed by the user.
Note — The ONT and its services can be preprovisioned at the
P-OLT before or after the ONT is installed.
The SLID at the ONT can be stored in volatile or non-volatile mode. In volatile mode, the SLID is delivered to the P-OLT in proprietary mode; in non-volatile mode, the SLID can be delivered to the P-OLT in registration ID or proprietary mode. The
SLID can be entered in hexadecimal or alphanumeric string format. See Table
for more information about SLID settings
Note — If you are reusing an ONT that was previously configured with a non-volatile SLID, the SLID must be reset to its default value.
If you are reusing an ONT that was previously configured with a volatile SLID, the SLID will automatically return to its default value when the ONT is powered off and on.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-55
5 — ONT management using an ONT interface
Parameter
Mode
String format
SLID value
Value
Volatile
Permanent
Registration
Hexadecimal
Alphanumeric
DEFAULT
Non-default value
Table 5-10 SLID settings
Description
In volatile mode:
• The SLID at the ONT returns to its default value after the ONT is powered off and on.
• The SLID is delivered to the P-OLT in the proprietary mode, which uses the proprietary
PLOAM message.
In permanent mode:
• The SLID at the ONT retains its configured value after the ONT is powered off and on.
• The SLID is delivered to the P-OLT in the proprietary mode, which uses the proprietary
PLOAM message.
In registration mode:
• The SLID at the ONT retains its configured value after the ONT is powered off and on.
• The SLID is delivered to the P-OLT in registration
ID mode, which uses the password PLOAM message defined in G.984.3.
Hexadecimal string of 0 to 9 and usually a to f or A to
F, with zeroes appended to a length of 20 characters
String of up to 10 characters (default)
The ONT is set to a default value.
—
This section shows you how to:
• view or retrieve the current SLID setting
• clear (reset) the SLID
• enter or modify a SLID
Prerequisites
The prerequisites are:
• To enter a SLID, the user access level of the ONT is read-write.
• To view current SLID settings, the user access level of the ONT is read only, or read-write.
• The ONT must have a SLID value of null or default before you can enter a new
SLID. To reset a SLID to its default value, you must clear it.
• The steps to access the interface are completed.
• See Procedure
5-1 for HTTP interface using the first Ethernet port.
• See Procedure
5-3 for CLI interface using the craft port.
• See Procedure
5-6 for HTTP interface for Package C ONTs.
• See Procedure
5-7 for Package C ONT CLI interface using the craft port.
• See Procedure
5-8 for Package C ONT CLI interface using an Ethernet port.
5-56 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedures using HTTP interface
The following procedures provide the steps to view the current SLID settings, to clear the SLID, and to enter the SLID at the ONT using the HTTP interface.
Note 1 — To enter or clear a SLID using an Ethernet connection, the
ONT must be disconnected from the PON optical cable.
Note 2 — You cannot change the SLID settings when the ONT is connected, ranged, and provisioned.
Procedure 5-38 To view the current SLID settings
1 From the Web-Management System window, click on the SLID Management tab, as shown in Figure
Figure 5-32 Main options in the Web-Management System window
The SLID window opens with the current SLID settings, as shown in Figure
.
Figure 5-33 SLID window where the SLID settings are described in Table
2 Click on the Refresh button to refresh the contents of the window.
3 STOP. This procedure is complete.
Procedure 5-39 To clear the SLID
1 Ensure that the ONT is disconnected from the PON optical cable.
2 From the SLID window, click on the Clear button to reset the SLID to its default settings.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-57
5 — ONT management using an ONT interface
The SLID clear dialog box opens, as shown in Figure
.
Figure 5-34 SLID clear dialog box
3 Click on YES to reset the SLID. The SLID window is refreshed with the default SLID settings for the ONT.
Note — After a SLID is reset, the SLID value is DEFAULT.
4 STOP. This procedure is complete.
Procedure 5-40 To enter the SLID
1 Ensure that the ONT is disconnected from the PON optical cable.
2 From the SLID window, ensure that the SLID value is null or DEFAULT, as shown in Figure
.
Figure 5-35 SLID window
5-58 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
3 Enable one of the following radio buttons to set the Mode of the SLID:
• Volatile —In volatile mode, the SLID at the ONT returns to its default value after the ONT is powered off and on. A volatile SLID is always delivered to the
P-OLT in the proprietary mode, which uses the proprietary PLOAM message.
• Permanent —In permanent mode, the SLID at the ONT is stored in non-volatile mode, and is delivered to the P-OLT in proprietary mode, which uses the proprietary PLOAM message. A non-volatile SLID retains its configured value after the ONT is powered off and on.
• Registration —In registration mode, the SLID at the ONT is stored in non-volatile mode, and is delivered to the P-OLT in registration ID mode, which uses the password PLOAM message defined in G.984.3. A non-volatile SLID retains its configured value after the ONT is powered off and on.
4 Enable one of the following radio buttons to set the String format :
• Hexadecimal —20 characters of 0 to 9 and usually a to f or, A to F, with zeroes appended to a length of 20 characters
• Alphanumeric —up to 10 ASCII characters
Note — The default value is alphanumeric.
5 Type the SLID in the SLID Value box.
6 Click on the Apply button to apply the SLID to the ONT. The Set SLID dialog box opens, as shown in Figure
Figure 5-36 Set SLID dialog box
7 Click on Yes to set the SLID to its new value.
The status bar displays the message “The slid setting has been applied!”.
8 Connect the PON optical cable to the ONT.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-59
5 — ONT management using an ONT interface
9 Perform one of the following to provision ONT and services: a If the ONT and services were preprovisioned at the P-OLT, the P-OLT will automatically range and provision the ONT, after the ONT is connected to the
PON optical cable.
b If the ONT and services were not pre-provisioned at the P-OLT, notify the TL1 or network manager GUI operator to provision the ONT and services at the
P-OLT using SLID.
10 STOP. This procedure is complete.
Procedures using CLI interface
The following procedures provide the steps to view the current SLID settings, to clear the SLID, and to enter the SLID using the CLI interface.
Note — To enter or clear a slid:
• If you are using an Ethernet connection, the ONT must be disconnected from the PON optical cable.
• If you are using a craft connection, the ONT can be connected or disconnected from the PON optical cable. However, if you configure the SLID with the ONT connected to the PON optical cable, the data at the ONT is not changed; the data at the ONT is only changed after the ONT reranges. Rerange the ONT by disconnecting and reconnecting the PON optical cable, which generates a NEWONT alarm.
Procedure 5-41 To view current SLID settings
1 Choose option 4, Retrieve SLID , from the
.
The system displays the string format, the mode, and the value of the SLID.
Example:
The SLID in ALPHANUMERIC MODE (Volatile) : DEFAULT where the SLID settings are described in Table
2 STOP. This procedure is complete.
5-60 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Procedure 5-42 To clear the SLID
1 Perform one of the following: a If you are using an Ethernet port, ensure that the ONT is disconnected from the PON optical cable.
b If you are using a craft port, you can clear the SLID with the ONT connected to or disconnected from the PON optical cable.
2 Choose option 5, Clear SLID , from the
to clear the SLID.
The ONT sets the SLID to the default value, and the following message appears:
SLID cleared successfully!
3 Choose option 4, Retrieve SLID from the main menu to verify that the SLID is reset to its default value.
4 STOP. This procedure is complete.
Procedure 5-43 To enter the SLID
1 Perform one of the following: a If you are using an Ethernet port, ensure that the ONT is disconnected from the PON optical cable.
b If you are using a craft port, you can enter the SLID with the ONT connected or disconnected from the PON optical cable.
2 Choose option 4, Retrieve SLID , from the
to ensure that the SLID is set to DEFAULT or null.
3 Perform one of the following from the main menu a Choose option 1, Enter SLID in volatile mode , to enter a volatile SLID.
b Choose option 2, Enter SLID in permanent mode , to enter a non-volatile
SLID delivered in proprietary mode.
c Choose option 3, Enter SLID in registration mode , to enter a non-volatile
SLID delivered in registration ID mode.
The following appears:
Enter Subscriber Location Id
> ALPHANUMERIC MODE (Length(1..10)):
> HEX MODE (Length(1..20))
> Note: FOR HEX MODE -- APPEND THE VALUE WITH 0x
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-61
5 — ONT management using an ONT interface
4 Perform one of the following to enter the SLID value in alphanumeric or hexadecimal format: a In alphanumeric format, enter the SLID up to 10 ASCII characters of 0 to 9, a to z, or A to Z.
b In hexadecimal format, enter the SLID up to 20 characters of 0 to 9, a to f, or A to F, with zeroes appended to a length of 20 characters.
5 Choose option 4, Retrieve SLID , to verify that the SLID was entered correctly.
6 Perform one of the following to connect the ONT to the PON: a If the ONT is disconnected from the PON, connect the PON optical cable to the ONT. b If the ONT is connected to the PON, disconnect, and then reconnect the PON optical cable.
7 Perform one of the following to provision the ONT and services: a If the ONT and services were preprovisioned at the P-OLT, the P-OLT will automatically range and provision the ONT, after the ONT is connected to the
PON optical cable.
b If the ONT and services were not preprovisioned at the P-OLT, notify the TL1 or network manager GUI operator to provision the ONT and services at the
P-OLT using SLID.
8 STOP. This procedure is complete.
Procedures using HTTP interface for Package C ONTs
The following procedures provide the steps to view the current SLID settings and to enter a new SLID at the ONT using the HTTP interface for Package C ONTs.
Note — To enter or clear a SLID using an Ethernet connection, the
ONT must be disconnected from the PON optical cable.
Procedure 5-44 To view current SLID settings
1 Select the SLID option from the ONT Admin section of the navigation tree in the
GPON ONT window.
The SLID window appears; see Figure 5-37
.
5-62 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
Figure 5-37 SLID window
The current SLID settings are displayed in the Configured SLID and Current SLID fields.
2 If required, press Refresh to update the display of the configured and current SLID.
3 STOP. This procedure is complete.
Procedure 5-45 To enter the SLID
1 Select the SLID option from the ONT Admin section of the navigation tree in the
GPON ONT window.
The SLID window appears; see Figure 5-38
.
Figure 5-38 SLID window
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-63
5 — ONT management using an ONT interface
2 Perform one of the following to enter the new SLID value in alphanumeric or hexadecimal format in the Input New SLID field: a In alphanumeric format, enter a numeric string of up to 10 characters. b In hexadecimal format, enter a numeric string of up to 20 characters. The string must be prefixed with a zero.
3 Press Apply.
4 STOP. This procedure is complete.
Procedures using CLI interface for Package C ONTs
The following procedures provide the steps to retrieve the current SLID and to modify the SLID using the CLI interface provided with Package C ONTs.
Note — To enter or clear a slid:
• If you are using an Ethernet connection, the ONT must be disconnected from the PON optical cable.
• If you are using a craft connection, the ONT can be connected or disconnected from the PON optical cable. However, if you modify the SLID with the ONT connected to the PON optical cable, the data at the ONT is not changed; the data at the ONT is only changed after the ONT reranges. Rerange the ONT by disconnecting and reconnecting the PON optical cable, which generates a NEWONT alarm.
Procedure 5-46 To retrieve the current SLID settings
1 Type S or s for Retrieve SLID
The system displays the current SLID in string format. The SLID settings are described in Table
.
2 STOP. This procedure is complete.
5-64
Procedure 5-47 To modify the SLID
1 Type M or m for Modify SLID
.
2 Perform one of the following to enter the new SLID value in alphanumeric or hexadecimal format: a In alphanumeric format, enter a numeric string of up to 10 characters. b In hexadecimal format, enter a numeric string of up to 20 characters. The string must be prefixed with a zero.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
3 Press Enter.
4 If necessary, reboot the ONT (Procedure
5-28 ) in order for the new SLID to take
effect immediately.
5 STOP. This procedure is complete.
Procedures using butt set
The following procedures provide the steps to clear the SLID and to enter a SLID at the ONT using a butt set.
Note — To use a butt set:
• The ONT must be disconnected from the PON optical cable.
• The butt set must be connected to the first POTS port on the ONT.
• The SLID must be in decimal or hexadecimal format.
Procedure 5-48 To clear the SLID using a butt set
1 Ensure that the ONT is disconnected from the PON optical cable.
2 Reboot the ONT.
3 Connect the butt set to the first POTS port on the ONT.
4 Wait for the green POTS LED on the ONT to start flashing (one second on, and two seconds off).
5 Take the butt set off-hook.
6 Dial “*1#” to convert the permanent SLID to a volatile SLID.
When the ONT is powered off and on, the SLID is reset to its default value.
7 Power the ONT off and on to reset SLID to its default value.
8 Take the butt set on-hook to exit.
9 STOP. This procedure is complete.
Procedure 5-49 To enter the SLID using a butt set
1 Ensure that the ONT is disconnected from the PON optical cable.
2 Connect the butt set to the first POTS port on the ONT.
3 Wait for the green POTS LED on the ONT to start flashing (one second on, and two seconds off).
4 Take the butt set off-hook.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-65
5 — ONT management using an ONT interface
5 Perform one of the following to activate the dial tone: a For a volatile decimal SLID, dial “*”: b For a volatile hexadecimal SLID, dial “0*”.
c For a permanent decimal SLID:
• Dial “9* to deliver the SLID to the P-OLT using the proprietary PLOAM message.
• Dial “8*” to deliver the SLID to the P-OLT using the password PLOAM message defined in G.984.3
d For a permanent hexadecimal SLID:
• Dial “90* to deliver the SLID to the P-OLT using the proprietary PLOAM message.
• Dial “80*” to deliver the SLID to the P-OLT using the password PLOAM message defined in G.984.3
The dial tone is activated.
6 After the dial tone is activated, perform one of the following to dial the SLID value: a For a decimal SLID, dial the SLID value up to 10 digits long.
b For a hexadecimal SLID, dial the SLID value up to 20 digits long. Only digits in the range 0 to 9 are accepted.
7 Dial “#” to send the SLID number to the ONT.
The ONT exits the SLID input mode and enters the SLID output mode, and sends confirmation tone and SLID number. If a hexadecimal SLID is less than 20 digits, the ONT automatically appends zeroes to the end of the SLID.
8 Verify that the SLID was entered correctly.
5-66 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
If a currently provisioned SLID contains nonnumeric digits, the ONT exits the SLID output mode. If a currently provisioned SLID contains only numeric digits, the value is displayed back to the installer using the POTS LED on the ONT. Each SLID number is determined by counting the number of times that the POTS LED on the
ONT flashes, as follows:
• If the SLID is in decimal format:
• For the numbers 1 to 9, the flash pattern is 0.5 s of green light followed by
1 s of no light, repeated the number of times necessary to correspond to the number.
• For the number 0, the flash pattern is 0.5 s of green light followed by 1 s of no light repeated 10 times.
• There is a 3s interval between digits.
• If the SLID is in hexadecimal format:
• For the numbers 1 to 9, the flash pattern is 0.5 s of green light followed by
0.5 s of no light, repeated the number of times necessary to correspond to the number.
• For the number 0, the flash pattern is 0.5 s of green light followed by 0.5 s of no light repeated 10 times.
• There is a 3s interval between digits.
Note 1 — The SLID number displays more slowly in decimal format than in hexadecimal format.
Note 2 — The SLID number can be verified at any time by connecting a butt set to the first POTS port and dialing the “#” key.
9 Take the butt set on-hook to exit the SLID output mode.
10 Connect the PON optical cable to the ONT.
The ONT exits all SLID management modes.
11 Perform one of the following to provision ONT and services: a If the ONT and services were preprovisioned at the P-OLT, the P-OLT will automatically range and provision the ONT, after the ONT is connected to the
PON optical cable.
b If the ONT and services were not preprovisioned at the P-OLT, notify the TL1 or network manager GUI operator to provision the ONT and services at the
P-OLT using SLID.
12 STOP. This procedure is complete.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-67
5 — ONT management using an ONT interface
5.15
XML file configuration data for package C ONTs
For ONTs that are shipped with an XML file already configured, the data that defines
L3 interface and WiFi behavior is pre-configured with default values. Use an XML file editor to update the file to meet WiFi requirements. See the appropriate unit data sheet for more information. Table lists the XML file configuration options, sample
XML, and parameter ranges.
Table 5-11 XML file configuration data for package C ONTs
XML parameter Parameter values
WAN interface configuration instanceID
WANName
Specifies the instance ID. Set to 1 and cannot be changed
Specifies the WAN name, an alphanumeric string of 1 to 256 characters
IpGetMode
IpAddress
Specifies the method used by the device to retrieve its IPv4 address. The options are:
• static
• dhcp
• pppoe
Specifies the IPv4 address in dotted decimal notation format. Can be configured when
IpGetMode is set to static.
PPPoEUserName
PPPoEUserPasswd
Gateway dnsdomainname
DNSServer1
DNSServer2
Specifies the user name for the PPPoE connection. Can be configured when
IpGetMode is set to pppoe.
Specifies the user password for the PPPoE connection. Can be configured when
IpGetMode is set to pppoe.
Specifies the IPv4 address of the network device when the default IP address does not match any routing table routes. Can be configured when IpGetMode is set to dhcp
Specifies the DNS domain name of the DHCP gateway device. Can be configured when
IpGetMode is set to dhcp
Specifies the DNS primary server IP address for the DHCP gateway device. Can be configured when IpGetMode is set to dhcp
Specifies the DNS secondary server IP address for the DHCP gateway device. Can be configured when IpGetMode is set to dhcp
LAN type
(1 of 5)
Sample XML
<Layer3>
<WANInterface
NumberOfInstance="1"
MaxNumber="1">
<WANInterfaceConfig
InstanceID="1"
WANName="wan1"
IpGetMode="static"
IpAddress="222.10.60.88"
SubMask="255.255.255.0"
PPPoEUserName=""
PPPoEUserPasswd=""
Gateway="222.10.60.254"
DNSDomainName="tele.com"
DNSServer1="210.11.123.13"
DNSServer2="210.11.123.13"
WANID="1"/>
</WANInterface>
Information
—
—
Use standard
IPv4 addressing for static.
—
—
—
—
—
—
—
5-68 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
XML parameter
L3Port
Parameter values
Specifies the Layer 3 LAN port in unsigned long bit definition format.
Bit31~16 : 0
Bit15~8: wireless LAN port
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
| bit15:~bit12:reserved | bit11:WLAN_4 | bit10:WLAN_3 | bit9:WLAN_2 | bit8:WLAN_1 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Bit7~0: LAN port
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
| bit7:~bit4:reserved | bit3:LAN_4 | bit2:LAN_3 | bit1:LAN_2 | bit0:LAN_1 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ default: 0;
1: enable;
LAN interface configuration instanceID Specifies the instance ID. Set to 1 and cannot be changed
LANName
IpAddress
Specifies the LAN name, an alphanumeric string of 1 to 256 characters
Specifies the IPv4 address of the LAN interface in dotted decimal notation format.
SubnetMask Specifies the IP address subnet mask of the
LAN interface in dotted decimal format. The default is 255.255.255.0.
DHCPSState Specifies whether DHCP is enabled or disabled. The options are:
• enable (default)
• disable
Sample XML
<LANType L3Port="0"/>
<LANInterface
NumberOfInstance="1"
MaxNumber="2">
<LANInterfaceInstance
InstanceID="1"
LANName="Primary"
IpAddr="192.168.100.1"
SubnetMask="255.255.255.0"
DHCPServerEnable="enable"
StartIP="192.168.100.100"
EndIP="192.168.100.200"
Leasetime="259200"
Option60="dhcpOp"/>
</LANInterface>
—
—
—
Information
—
—
When enabled, the device assigns IP addresses, an IP default gateway, and
DNS servers.
— StartIP
EndIP
Leasetime
Option60 uPnP configuration
(2 of 5)
Specifies the start and end range of the
DHCP IP address pool.
Specifies the client IP pool lease time, in seconds. The range is 0 to 6048000. The default is 259200 (72 hours). The maximum is 70 days
Specifies the IP address for the device that transits the DHCP discovery packets with the matched option 60 functionality.
—
—
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-69
5 — ONT management using an ONT interface
XML parameter Parameter values
UPnPEnable
Security configuration
Specifies whether LAN uPnP is enabled or disabled. The options are:
• enable (default)
• disable
FTP
HTTP
Specifies whether FTP service is enabled or disabled from the WAN. The options are:
• enable
• disable (default)
Specifies whether HTTP service is enabled or disabled from the WAN. The options are:
• enable
• disable (default)
TELNET
SSH
Specifies whether TELNET service is enabled or disabled from the WAN. The options are:
• enable
• disable (default)
Specifies whether SSH service is enabled or disabled from the WAN. The options are:
• enable
• disable (default)
LAN service ACL configuration
FTP
HTTP
Specifies whether FTP service is enabled or disabled from the LAN. The options are:
• enable
• disable (default)
Specifies whether HTTP service is enabled or disabled from the LAN. The options are:
• enable (default)
• disable
Wireless WiFi configuration wifiNetMode
WiFiChBW wifiNetChannel
Specifies the WiFi mode for the device. The options are:
• mixed for 802.11b/g/n
• disable for no WiFi (default)
Specifies the WiFi channel bandwidth. The options are:
• auto (default)
• 20
• 40
Specifies the net channel. When WiFiChBW is set to auto, the option is auto. When
WiFiChBW is set to 20, the options are 1, 2,
3, 4, 5, 6, 7, 8, 9, 10, 11, 12, or 13. When
WiFiChBW is set to 40, the options are auto or the wifiWideNetCh value plus or minus 2.
wifiWideNetCh Specifies the wide net channel. You can specify the parameter when the wifiNetChannel is set to 40. The options are auto, 3, 4, 5, 6, 7, 8, 9, 10, 11
(3 of 5)
Sample XML
<LANUPnPConfig
UPnPEnable="enable"/>
Information
—
<Security>
<WANServiceACL FTP="disable"
HTTP="disable"
TELNET="disable"
SSH="disable"/>
Not currently supported
—
<LANServiceACL FTP="disable"
HTTP="enable" />
<Wireless>
<WifiNetwork wifiNetMode="mixed"
WiFiChBW="auto" wifiNetChannel="auto" wifiWideNetCh="auto" />
Not currently supported
—
Not currently supported
—
—
—
—
—
5-70 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
5 — ONT management using an ONT interface
XML parameter Parameter values
Wireless WiFi SSID configuration
Sample XML wifiSsidAdmin wifiNetSsid
Specifies the SSID administration status. The options are:
• enable
• disable
Specifies the SSID name; which is a 1 to 32 alphanumeric character string.
<WifiSsid1>
<Wifi1SsidCfg wifiSsidAdmin="enable" wifiNetSsid="cigrg" wifiNetSsidBc="enable" wifiWps="enable" wifiLegacy="disable" secMode="wep" /> wifiNetSsidBc wifiWps wifiLegacy
Specifies whether to enable or disable WiFi
SSID broadcast ID. The options are:
• enable
• disable
Specifies whether to enable or disable WPS status. This parameter can be set when the
WiFiChBW parameter is set to 40. The options are:
• enable
• disable
Specifies whether to enable or disable legacy mode, supporting 802.1g 54 Mb/s speeds. The options are:
• enable
• disable secMode Specifies the security mode. The options are:
• open
• wep
• wpa-per
• wpa-ent
WPA personal security configuration
You can configure the parameters when the secMode is set to wpa-per (personal) wpaVer encryptionAlgo personalKey
Specifies the WPA version. The value is an integer from 1 to 2.
Specifies the encryption algorithm used.
The options are:
• aes
• tkip
Specifies the encryption key. The key is an alphanumeric string of 0 to 32 characters
<Wifi1SecuWpaPersonal wpaVer="1" encryptionAlgo="tkip" personalKey="" groupKeyRenewal="3600" /> groupKeyRenewal Specifies the encryption key renewal period. The value, in seconds, ranges from 1 to 65535 seconds. The default is 3600 s (1 hour)
WPA enterprise security configuration
You can configure the parameters when the secMode is set to wpa-ent (enterprise)
(4 of 5)
—
—
—
—
—
—
—
Information
—
—
Value cannot be changed from default.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
5-71
5 — ONT management using an ONT interface
XML parameter wpaVer encryptionAlgo personalKey
Parameter values
Specifies the WPA version. The value is an integer from 1 to 2.
Specifies the encryption algorithm used.
The options are:
• aes
• tkip
Specifies the encryption key. The key is an alphanumeric string of 0 to 32 characters
Sample XML
<Wifi1SecuWpaEnterprise wpaVer="1" encryptionAlgo="tkip" radiusServerIp="" radiusPort="1812" enterpriseKey="" keyRenwal="900" />
Information
—
—
— groupKeyRenewal radiusServerIp radiusPort
Specifies the encryption key renewal period. The value, in seconds, ranges from 1 to 65535 seconds. The default is 900 s (15 minutes)
Specifies the IPv4 address of the authenticating RADIUS server. The value is an IP address in v4 format.
Specifies the port of the authenticating
RADIUS server. The value is a port number
(integer) from 1 to 65535. The default is
1812.
—
—
—
Hardware configuration -- layer 3 profile extension layer3PortMapping Specifies the Layer 3 port mapping bitmap setting. Bit 31 to Bit 4 are reserved. Bit 3:
LAN port 4; Bit 2: LAN port 3; Bit 1: LAN port
2; Bit 0: LAN port 1. The options are:
• 0: disabled Layer 3 functions at this port
• 1: enable Layer 3 functions at this port
<Layer3Profile>
<Layer3PortMapping>0x000000
07</Layer3PortMapping>
</Layer3Profile>
</HW_Configuration>
WEP personal security configuration
You can configure the parameters when the secMode is set to wep wepKeydefault wepPassphrase
Specifies the default WEP key value. The value is an integer from 1 to 4.
Specifies the WEP passphrase. algorithm used. The value is a string from 1 to 8 hexidecimal characters.
<Wifi1SecuWep wepKeydefault="1" wepPassphrase="" wepKey1="" wepKey2="" wepKey3="" wepKey4="" />
</WifiSsid1>
—
— wepKeyLen wepKey1~4 radiusServerIp radiusPort
Specifies the WEP key length. The value is
40 or 104.
Specifies the first to fourth WEP keys. Each key is a string of 1 to 40 characters.
Specifies the IPv4 address of the authenticating RADIUS server. The value is an IP address in v4 format.
Specifies the port of the authenticating
RADIUS server. The value is a port number
(integer) from 1 to 65535. The default is
1812.
SSID 2 security configuration
You can configure two sets of SSID parameters. repeat the above parameters substituting Wifi2 for Wifi1
—
—
—
—
For example:
0x00000007 will enable L3 function in port
1/2/3; 0x8 will enable L3 function in port
4
(5 of 5)
5-72 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
13 — I-241G-A unit data sheet
13.1 I-241G-A part numbers and identification 13-2
13.2 I-241G-A general description 13-2
13.3 I-241G-A software and installation feature support 13-2
13.4 I-241G-A interfaces and interface capacity 13-3
13.6 I-241G-A detailed specifications 13-6
13.7 I-241G-A GEM ports and T-CONTs 13-8
13.8 I-241G-A power support 13-8
13.9 I-241G-A functional blocks 13-8
13.10 I-241G-A standards compliance 13-11
13.11 I-241G-A special considerations 13-11
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
13-1
13 — I-241G-A unit data sheet
13.1
I-241G-A part numbers and identification
Table
13-1 provides identification information about I-241G-A indoor ONTs.
Part number
3FE 60344 AA
Table 13-1 I-241G-A part numbers and identification
Description
I-241G-A I-241G-A GPON I-series ONT, version A, asymmetric, 2 POTS, 4 Ethernet
10/100/1000Base-T, and 1 RF video
CLEI
—
CPR
—
ECI/Bar code
—
Note
(1) See Chapter
2 Part numbers, ordering, and deployment configuration overview
for product identification information.
13.2
I-241G-A general description
13.3
The I-241G-A indoor ONT provides the subscriber interface for the network. The
ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices. The ONT is compatible with all existing subscriber equipment, including analog phones with both tone and rotary dial capabilities, cordless phones, modems, fax machines, and caller ID boxes (Type I, Type II, and
Type III).
The I-241G-A indoor ONT provides the following functions:
• FSAN GPON standards compliant
• Network management support
• IP video with multistage IGMPv3 or IGMPv2 for channel change
• network demarcation for all services in an open business model
• voice interworking function from the analog POTS lines to the VoIP/Ethernet layers
• interworking functions between the GEM and Ethernet layers
• interworking functions between the PON optical overlay and the RF video interface
• mux and demux functions to the PON
• optical to electrical conversion
• G984.4 standard and revised compliant OMCI interface for ONT management and provisioning
I-241G-A software and installation feature support
Table
13-2 provides a list of software-based features and installation information
supported by I-241G-A indoor ONTs.
13-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
13 — I-241G-A unit data sheet
Table 13-2 I-241G-A ONT software feature support
Features
General ONT and MDU overview
Service interface specifications
Services supported
Chapter
ONT and MDU general and interface technical specifications
—
Cross reference for more information
ONT and MDU general descriptions of features and functions
Ethernet interface specifications
RF video interface specifications for video overlay
•
Coaxial connectivity in the home and design guidelines
•
•
See the appropriate P-OLT user documentation for service creation procedures and descriptions.
—
—
RSSI specifications
Wi-Fi specifications
Optical budget
Location and installation options
HTTP management
Statistics and performance monitoring
Supported UPS configurations
—
—
ONT and MDU general and interface technical specifications
How to install and replace an I-241G-A indoor ONT
Information necessary to manage an
ONT at a local site using an HTTP interface, CLI interface, CLI interface or butt set.
ONT and MDU statistics and performance monitoring
Part numbers, ordering, and deployment configuration overview
Install an I-241G-A indoor ONT
Replace an I-241G-A indoor ONT
ONT management using an ONT interface
Performance monitoring statistics for Package A
ONT and MDU to UPS or power adapter compatibility support
13.4
I-241G-A interfaces and interface capacity
Table
13-3 describes the supported interfaces and interface capacity for I-241G-A
ONTs.
Table 13-3 I-241G-A ONT interface connection capacity
ONT type and model
I-241G-A
Maximum capacity
POTS 10/
100/
BASE-T
2 —
10/
100/
1000
BASE-T
4
RF video
(CATV)
1
MoCA
—
VDSL2 DS1/E1 Local craft
— — —
GPON
SC/APC
1
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
13-3
13 — I-241G-A unit data sheet
I-241G-A connections and components
The I-241G-A ONTs are for indoor deployment and can be installed vertically or horizontally. Connections to the SC/APC, RJ-45, RJ-11, and coaxial connectors are on the outside of the ONT.
shows the physical connections for I-241G-A indoor ONTs.
Figure 13-1 I-241G-A indoor ONT connections
2 1 1 2 3 4
PON
Video coaxial connector
RJ-11 phone connectors
Ethernet ports
Fiber optic port
Power connection
19397
Table
13-4 describes the I-241G-A indoor ONT physical connections.
Table 13-4 I-241G-A indoor ONT connections
Connection
POTS connections
RF video coaxial connector (Type F)
Fiber optic port
Ethernet ports
Power
Description
This connection is provided through an RJ-11 phone connector.
This connection is provided through a coaxial cable.
This connection is provided through a fiber optic cable.
This connection is provided through an Ethernet RJ-45 cable. Up to four
Ethernet connections are supported.The Ethernet port can support both data and in-band video services on all four interfaces.
This connection is provided through a cable to the ac/dc power converter.
13.5
I-241G-A ONT LEDs
shows the I-241G-A indoor ONT LEDs.
13-4 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
13 — I-241G-A unit data sheet
Figure 13-2 I-241G-A indoor ONT LEDs
PWR FAIL Video DATA1 DATA2 DATA3 DATA4 NTWK MGMT VOICE
19398
Table
13-5 lists I-241G-A indoor ONT LEDs
Table 13-5 I-241G-A indoor ONT LEDs
Indicator
PWR
FAIL
NTWK
DATA1
DATA2
DATA3
DATA4
LED color and behavior
Off
Green solid
Off
Red solid
Off
Red solid
Off
Green solid
Green flashing
Off
Green solid
Green flashing
Off
Green solid
Green flashing
Off
Green solid
Green flashing
Off
Green solid
MGMT Off
Green solid
Green flashing
When device is not connected to the PON
(1 of 2)
LED behavior description
Not powered
3.3 V dc power is available
Equipment is 100% operational
Equipment failure or ONT not ranged/synchronized
Video signal is not provisioned, or is above the acceptable level
Video signal is provisioned and below acceptable level
Ethernet 0 link failure
Ethernet 0 link is good
Ethernet 0 link is in Tx/Rx activity
Ethernet 1 link failure
Ethernet 1 link is good
Ethernet 1 link is in Tx/Rx activity
Ethernet 2 link failure
Ethernet 2 link is good
Ethernet 2 link is in Tx/Rx activity
Ethernet 3 link failure
Ethernet 3 link is good
Ethernet 3 link is in Tx/Rx activity
1490 nm data path is unavailable
1490 nm data path is available
No communication between P-OLT and the ONT
Full communication between P-OLT and the ONT
ONT is disabled
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
13-5
13 — I-241G-A unit data sheet
Indicator
LED color and behavior
Off
Green flashing periodic
Green flashing patterned
When device is connected to the PON
VOICE Off
Green solid
LED behavior description
No SLID activity and all phones on-hook
SLID input mode
Provisioned SLID in SLID output mode
All phones are on-hook, POTS is not provisioned, or no phones connected
Any customer is off-hook
(2 of 2)
Notes
(1) The RF TV LED is only functional for RF video-equipped ONTs.
(2)
See SLID and LED behavior for a description of SLID output mode LEDs.
Indicator
LINK
MODE
Table
13-6 lists the RJ-45 LEDs on I-241G-A indoor ONTs.
Table 13-6 I-241G-A indoor ONT RJ-45 LEDs
LED color and behavior
Off
Green solid
Green flashing
Off
Green solid
Green flashing
LED behavior description
Link not detected
Link active
Link detected and activity present
10 Mb/s operation
100 Mb/s operation
1000 Mb/s operation
Note
(1) LINK and MODE LEDs are reversed on the I-240G-A and I-241G-A
13.6
I-241G-A detailed specifications
Table
13-7 lists the physical specifications for I-241G-A indoor ONTs.
Table 13-7 I-241G-A indoor ONT physical specifications
Dimensions
Length
Width
Height without cable tray
Height with cable tray
Weight without cable tray [within ± 0.5 lb (0.23 kg)]
Weight with cable tray [within ± 0.5 lb (0.23 kg)]
Specifications
8.2 in. (20.8 cm)
5.6 in. (14.3 cm)
1.3 in. (3.3 cm)
1.9 in. (4.8 cm)
1.25 lb (0.57 kg)
1.41 lb (0.64 kg)
13-6 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
13 — I-241G-A unit data sheet
Table
13-8 lists the power consumption specifications for I-241G-A indoor ONTs.
Table 13-8 I-241G-A indoor ONT power consumption specifications
Mnemonic Maximum power (Not to exceed)
I-241G-A 13 W
Condition
2 POTS off-hook, 4
Gig-E, Video operational
Minimum power
6.5 W
Condition
2 POTS on-hook, other interfaces/services not provisioned
Table
13-9 lists the environmental specifications for I-241G-A indoor ONTs.
Table 13-9 I-241G-A indoor ONT environmental specifications
Mounting method Temperature range and humidity
Indoor 10/100/1000Base-T Gigabit Ethernet ONTs (I-241G-A)
Desk or wall mounted
Operating:
32 ° F to 104 ° F (0 ° C to 40 ° C) ambient temperature
5% to 85% relative humidity, non-condensing
Maximum rate of temperature change is 32.9
° F
(0.5
° C) per hour
Storage:
-13 ° F to 133 ° F (-25 ° C to 55 ° C)
5% to 93% relative humidity, non-condensing
Altitude
Maximum operating altitude is 10 000 ft
(3048 m) above mean sea level
Maximum non-operating altitude is 40 000 ft (12
192 m) above mean sea level
Table
lists RF video interface specifications for I-241G-A indoor ONTs.
Table 13-10 I-241G-A ONT RF video interface specifications
RF video features
RF output level
RF slope correction (tilt)
Optical power range
CNR
CSO/CTB
MER
QAM signal-to-noise ratio
Measurement assumptions
Channel load
(1 of 2)
Channel mix 80 analog/33 digital
+18 dBmV @ 450 MHz using a per analog channel measurement
2 dB from 50 to 870 MHz
+1 to -6 dB
45 dB
53 dB
32 dB
40 dB
80 analog and 33 digital
Channel mix 40 analog/63 digital
+18 dBmV @ 450 MHz using a per analog channel measurement
2 dB from 50 to 870 MHz
+2 to -7 dB
46 dB
55 dB
32 dB
40 dB
40 analog and 63 digital
Channel mix 0 analog/135 digital
+12 dBmV @ 450 MHz using a per digital channel measurement
—
—
2 dB from 88 to 870 MHz
+1 to -9 dB
32 dB
40 dB
0 analog and 135 digital
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
13-7
13 — I-241G-A unit data sheet
RF video features
Digital backoff QAM-256
Digital backoff QAM-64
PON input CNR
Channel mix 80 analog/33 digital (1)
6 dB
10 dB
52 dB
Channel mix 40 analog/63 digital
6 dB
10 dB
52 dB
Channel mix 0 analog/135 digital
6 dB
10 dB
52 dB
(2 of 2)
Note
(1) It is the responsibility of the customer installation crew to ensure proper on-site layout of video distribution by verifying that the output power at the end devices, such as the TV, VCR, and STB, is between 0 to 18 dBmV.
13.7
I-241G-A GEM ports and T-CONTs
lists the maximum number of supported T-CONTs and GEM ports. Not all ONTs will be supported in all of the releases indicated the table. See the appropriate release Customer Release Notes for the most accurate list of supported devices.
Table 13-11 I-241G-A indoor ONTs capacity for GEM ports and T-CONTs per package and release
Maximum Notes ONT or MDU
Package A ONTs
GEM ports per indoor or outdoor ONT
Release
All
T-CONTs per indoor or outdoor ONT
All
20
21
22 are present: 20 are available, 2 are reserved for OMCI and debugging
22 are present: 21 are available, 1 is reserved for OMCI
13.8
13.9
I-241G-A power support
The following power supply supports the I-241G-A indoor ONT. Click on the link for more information.
• Emerson 24 W AC/DC switching power adapter unit data sheet
I-241G-A functional blocks
Table
describes the supported interfaces for I-241G-A indoor ONTs.
13-8 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
13 — I-241G-A unit data sheet
Table 13-12 I-241G-A indoor ONT interfaces
ONT category description Interface capacity
POTS ports
Ethernet ports
RF video connectors
Single-residence indoor
ONTs (I-241G-A)
2 4 1
POTS/ VDSL2 /
10/100/1000
BASE-T
Ethernet connectors
0
DS1/E1
0
ONT SoC technology is an integrated system that provides the GPON, voice, and data (including IP video) subsystems. It provides two key connection functions: connecting the ONT to the GPON and the connecting the ONT to subscriber equipment. The voice subsystem supports RJ-11 ports, and the data and IP video subsystems support RJ-45 ports. The ONT connects to the GPON using a optical connector.
The GPON connection performs a GPON transmission convergence (TC) layer function. The GPON signal from the P-OLT terminates at a diplexer. The diplexer is an optical module that performs optical and electrical conversion. The diplexer
interfaces with the GPON MAC on the SoC. Figure 13-3
shows an ONT with a diplexer, four POTS, and two Ethernet ports.
Figure 13-3 ONT with a diplexer
Power
Converter
GPON Diplexer SOC
POTS (4)
Ethernet (2)
RJ-11
RJ-45
18783
ONT SoC technology serves as the main hardware block for the I-241G-A indoor
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
13-9
13 — I-241G-A unit data sheet
Figure 13-4 I-241G-A ONT hardware block
POTS ports
Control processor
SoC DSP
SoC Bridge
Ethernet
MACs
GPON
MAC
Ethernet ports GPON
19421
ONT SoC technology consists of five key elements:
• GPON MAC
The GPON MAC element on the SoC provides the GPON interface to the TC layer via the optical diplexer or triplexer (if using RF video). This interface supports the FSAN standards compliant GEM mode transport and provides AES,
FEC, and data fragmentation functionality over the GPON as described in
G.984.3 (GPON TC Layer) ITU specification.
• Ethernet MAC
The SoC provides an Ethernet PHY device (either 10/100BaseT or
10/100/1000BaseT) between the GMII interface and the RJ-45 port.
• Digital Signal Processor (DSP) interface
The DSP provides voice processing and has a TDM interface to the
CODEC/SLIC devices.
• control processor
The control processor manages functions related to OMCI, IGMP, VoIP, and
Ethernet services.
• SoC bridge
The SoC bridge provides an integrated data channel between the Ethernet MAC, the GPON MAC, the DSP, the control processor, and the other integrated elements such as flash memory, SDRAM, the local bus controller, and the
DUART interface to the craft port if used.
These ONTs can also interact with additional hardware components to support functionality not provided by SoC technology. For example, MoCA and CES functionality require additional hardware support.
13-10 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
13 — I-241G-A unit data sheet
13.10
I-241G-A standards compliance
The I-241G-A indoor ONT is compliant with the following standards:
• G.983.2 (revised) support for OMCI interface for ONT management and provisioning
• G.984.3 support for Dynamic Bandwidth Allocation (DBA)
• G.984.3 support for Advanced Encryption System (AES) with operator enable/disable per port-ID level
• G.984.3 support for Forward Error Correction (FEC) in both upstream and downstream directions
• G984.4 (standard and revised) support for OMCI interface for ONT management and provisioning
13.11
I-241G-A special considerations
Upgrade considerations and limitations
Existing ONTs that use 7342 ISAM FTTU releases older than R04.06.xx and
R04.07.xx must be upgraded to use R04.00.10 software while assigned to a PON ID value smaller than 64. For this purpose, if split ratios larger than 1:64 are being deployed, you may choose to set aside the first PON ID as a staging point.
I-241G-A ONT considerations and limitations
Table
lists the considerations and limitations for I-241G-A indoor ONTs.
Table 13-13 I-241G-A ONT considerations and limitations
Considerations and limitations
No support for per VLAN protocol downstream tagging mode
In SVLAN cross-connect tunnel mode:
• use non-overlapping pbits since the use of the same pbits on two or more VLAN ports results in a mismatch alarm
• downstream frames sent with a single tag normally sent out on the user-side as untagged, will instead be sent as priority tagged
When using CVLAN translation, or when the same queue is used for multiple pbits, the highest pbit value in the queue in the downstream direction will be selected to stomp the pbit in the packet
Simultaneous configuration of a CVLAN port and an S-Tunnel on the same UNI will only be supported if these services are provisioned with non-overlapping pbits
The same VLAN port must be used when employing both protocol-based VLAN for PPPoE and
IPoE-based VLANs
When the VLAN is translated, the pbit value must be modified and the highest pbit value is mapped to that GEM port
When more than one Ethernet port is in VLAN translation mode, or set to flexible mode with IGMP channels created, the USERSIDE VLAN IDs of those services are different. All downstream multicast packets will be tagged on the UNI port with VLAN ID of 4094
Maximum use of multicast on 1 Ethernet port at a time
(1 of 2)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
13-11
13 — I-241G-A unit data sheet
Considerations and limitations
For C forwarder and S+C CC forwarder, if the VLAN port uses regenerated profiles or regenerated pbits, then the downstream traffic can only flow with the derived pbits
When either tip or ring is grounded, DGNONTPOTS tip to ground and ring to ground restrictive measurements are simultaneously reported as 0 ohms
(2 of 2)
In order to provide four GE ports on the I-241G-A indoor ONT, an Ethernet switch has been added between the SoC and the Ethernet ports; See Figure
Ethernet switch provides the following features:
• IGMP packet replication for multicast channels
• internal VLAN tagging to direct traffic to appropriate ports and priority queues
Figure 13-5 Ethernet switch
Power
Converter
GPON Triplexer SOC
POTS
Ethernet switch
RJ-11
RJ-45
Video amplifier F
19394
Note — The RF video amplifier is integrated with the triplexer. It is
shown split-out in Figure 13-5 to illustrate the functionality.
IGMP packet replication allows the I-241G-A to support IPTV on all four Ethernet channels at the same time. Internal VLAN tagging allows traffic to be routed and prioritized between the two Ethernet MACs on the SoC and the Ethernet switch and the appropriate subscriber RJ-45 ports.
Downstream multicast traffic received on a user side C-VLAN tagged port will use
VLAN ID 4094 and have a P-bit value of 6.
The I-241G-A ONTs do not support downstream priority-tagged traffic on their
ONT UNIs. Priority-tagged frames are dropped. When an unstacked VLAN is provisioned on the ONT UNI, downstream traffic that is single tagged is dropped.
13-12 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
13 — I-241G-A unit data sheet
The new Ethernet switch functional block and the additional Ethernet switch features have modified certain VLAN tagging and priority queuing behaviors. The following sections describe these modifications.
Note 1 — Due to certain Ethernet switch restrictions, the I-241G-A provides up to 4 IP, 4 MAC, or 2 pairs of MAC/IP based anti-spoofing
(static only). MAC, IP, and MAC/IP anti-spoofing only works on both
IPoE packets.
Note 2 — Congestion may occur if Ethernet ports 1 and 2 or ports 3 and 4 are each set to 1000Base-T and are being used simultaneously.
See the ONT Customer Release Notes for this product for throughput details.
VLAN tagging behavior
Before traffic can be routed to and from the I-241G-A ONT the following conditions must be met:
• The CVLAN ID of any HSI service cannot be 0.
• Default P-bits must be configured on each Ethernet port.
This can be configured using the ENT-QOS-MARKPROF command. See the appropriate P-OLT Operations and Maintenance Procedure Guide for more information.
• When port-to-port communication is disabled, a default C-VLAN must be created for each Ethernet port. The VLAN must be unique for Ethernet port 1 and 2 or 3 and 4 on the ONT. The C-VLAN packet received at the ONT must be the same as the default C-VLAN or the packet is dropped. When port-to-port communication is enabled, each of the four Ethernet ports must have an unique
C-VLAN. The default VLAN can be configured using the CVLANDEF parameter.
• DSCP to 1P mapping rules are reduced from 64 to 8 with only the highest 3 bits
of the DSCP area used to determine P-bit value; see Table 13-14 .
This can be configured using the ENT-PROFILE-DSCPBITMAP command. See the appropriate P-OLT Operations and Maintenance Procedure Guide for more information.
Table 13-14 Default DSCP to P-bit mapping
DSCP
0 to 7
8 to 15
16 to 23
24 to 32
33 to 40
41 to 47
48 to 55
56 to 63 x x x x x x x
x
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
13-13
13 — I-241G-A unit data sheet
Traffic source
Untrusted
Trusted
Note
(1) Where x is a number from 0 to 7.
All VLAN tagging behavior operates as described in the appropriate P-OLT system documentation except as indicated in the following sections.
Upstream traffic handling (trusted and untrusted)
describes upstream VLAN tagging and P-bit allocation from trusted and untrusted traffic.
Table 13-15 Upstream untrusted and trusted tagging behavior
Traffic type
Untagged packets
P-bit tagged packets
P-bit and C-VLAN tagged packets
Untagged packets
P-bit tagged packets
P-bit and C-VLAN tagged packets
Ethernet switch behavior
Default C-VLAN and P-bits are added to the packets.
Default C-VLAN is added to the packets. P-bits are overwritten.
Received C-VLAN and P-bits are overwritten.
Default C-VLAN and P-bits are added to the packets.If the packets are IP, the DSCP to P-bits mapping is used. If the packets are PPPoE, the default P-bits are used.
Received P-bits are overwritten with default C-VLAN. P-bits are unchanged.
Received C-VLAN must match default VLAN or the packet is dropped. P-bits are unchanged.
Traffic mode
Strip tag
Tag through
Downstream traffic handling (strip tag and tag through)
Table
describes downstream VLAN tagging behavior for strip tag and tag through modes.
Table 13-16 Downstream untrusted and trusted tagging behavior
Traffic type
Untagged packets
P-bit tagged packets
C-VLAN tagged packets
Untagged packets
P-bit tagged packets
C-VLAN tagged packets
Transmitted to ONT port as
Untagged packet.
Untagged packet.
Untagged packet.
Untagged packet.
Default C-VLAN is added and the maximum number of P-bits will be accepted.
Default C-VLAN overwrites the received
C-VLAN and the maximum number of
P-bits will be accepted.
13-14 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
13 — I-241G-A unit data sheet
Traffic mode
VLAN translation
VLAN translation traffic handling
VLAN translation is a feature that allows that ONT to translate a C-VLAN into another C-VLAN. A network (NW) C-VLAN is used when data is sent over the
GPON network, and a user network interface (UNI) side C-VLAN is used when data is sent to customer equipment.
When using VLAN translation, the use the following configuration rules:
• Only a single UNI/NW C-VLAN pair is allowed per service.
• Overlapping P-bits can be used for difference services on UNI. However, in
VLAN pass-tru mode, the same P-bits as other services cannot be used on the
UNI. Overlapping P-bits are allowed only for non-default services.
Table
describes upstream VLAN tagging and P-bit allocation in VLAN translation mode.
Table 13-17 Upstream VLAN translation mode
Traffic type
Untagged packets
P-bit and C-VLAN tagged packets
Ethernet switch behavior
Default C-VLAN and P-bits are added to the packets.If the packets are IP, the DSCP to P-bits mapping is used. If the packets are PPPoE, the default P-bits are used. The C-VLAN and derived P-bits are now considered the UNI side C-VLAN.
Received UNI C-VLAN and P-bits must match NW C-VLAN configure P-bits or the packet is dropped.
Received UNI C-VLAN and P-bits must match NW C-VLAN configure P-bits or the packet is dropped.
Traffic mode
VLAN translation
Table
describes downstream VLAN tagging behavior for VLAN translation.
Table 13-18 Downstream VLAN translation behavior
Traffic type
Tagged packets
GPON behavior
Only accepts VLAN tagged traffic that matches the network VLAN ID configured using the ENT-SERVICE-HSI
TL1 command. All non matching VLAN IDs are dropped.
Only one service is allowed per VLAN.
Ethernet switch behavior
The Ethernet switch converts the network VLAN ID to the user side VLAN ID and forwards the packet to the appropriate port.
Ethertype classification and Ethertype with VLAN translation
Ethertype classification is used to classify traffic in the upstream direction based on the Ethernet type (IPoE or PPPoE). Ethertype classification operates as normal except that the received C-VLAN must match the default C-VLAN configured at the
ONT or the packet is dropped.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
13-15
13 — I-241G-A unit data sheet
Ethertype classification may also be used in conjunction with VLAN translation. All the considerations described in the VLAN translation section apply with the additional that the received C-VLAN and Ethertype must match the default NW
C-VLAN an Ethertype or the packet is dropped.
See the appropriate P-OLT system Product Information Manual for more information on Ethertype classification.
13-16 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 121 — Install an I-241G-A indoor
ONT
Purpose
This NTP provides the steps to install an I-241G-A indoor ONT.
General
The DLPs listed in this NTP describe the steps to install an I-241G-A indoor ONT.
Prerequisites
See the listed DLPs for prerequisites.
Recommended tools
You need the following tools for the installation:
• #2 Phillips screwdriver
• 1/4 in. (6 mm) flat blade screwdriver
• wire strippers
• fiber optic splicing tools
• RJ-45 cable plug crimp tool
• voltmeter or multimeter
• optical power meter
• wall mounting template
• drill and drill bits
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 121-1
NTP 121 — Install an I-241G-A indoor ONT
Safety information
Read the following safety information before installing the unit.
Danger 1 — Always contact the local utility company before you connect the enclosure to the utilities.
Danger 2 — Observe the local and national laws and regulations that may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections should be used when removing the fiber access cover of the indoor ONT.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged exposure to direct sunlight can damage the unit.
Note — Observe the following:
• The indoor ONT should be installed in accordance with the applicable requirements of the NEC or CEC. Local authorities and practices take precedence when there is conflict between the local standard and the NEC or CEC.
• The indoor ONT must be installed by qualified service personnel only.
• Indoor ONTs must be installed with cables that are suitably rated and listed for indoor use.
Procedure
Use this procedure to install an I-241G-A indoor ONT.
1 Prepare the cables at the site where the ONT will be installed (DLP 100 ).
2 Review the connection locations shown in Figure
.
NTP 121-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 121 — Install an I-241G-A indoor ONT
Figure NTP 121-1: I-241G-A indoor ONT connections
2 1 1 2 3 4
PON
Video coaxial connector
RJ-11 phone connectors
Ethernet ports
Fiber optic port
Power connection
19397
3 Place the indoor ONT unit: a On the flat surface, such as a desk, horizontally resting on its four plastic feet; go to step
.
b In the stand mount (3FE 60673 AA).
i Place the stand mount on the flat surface.
ii Slide the ONT into the opening on the stand mount, ensuring it is securely held. Figure
shows the stand mount.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 121-3
NTP 121 — Install an I-241G-A indoor ONT
Figure NTP 121-2: ONT in a stand mount
EQPT
PON
MGMT
Data 2
Data 1
19660 iii Go to step
.
c In the wall mount bracket.
i Measure and drill two holes in the wall where the ONT will be mounted.
The holes should be the same distance apart as the holes on the wall mounting bracket (83.3 mm apart, or 3.28 in).
ii Place mounting screws or bolts in the wall.
iii Lay the mounting bracket flat on a table.
iv Slide the ONT down over the mounting bracket until the fiber optic port is directly in front of the fiber optic port cable lead, as shown in
Figure
NTP 121-4 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 121 — Install an I-241G-A indoor ONT
Figure NTP 121-3: I-24x ONT with wall mounting bracket
2
3
4
PON
2 1 1 2 3
4
PON
19814 v Mount the ONT on the pre-installed screws or bolts in the bracket mounting holes. Ensure the ONT is firmly held in place by the bracket and is firmly secured to the wall.
4 Install the AC power converter and connect the power cable to the ONT (DLP 105 ).
5 Connect the Ethernet, POTS, and coaxial cables (DLP 101 , DLP 115 , and DLP 111 ).
6 If used, configure the SLID (DLP 121 ).
7 Connect the fiber optic cable (DLP 117 ).
8 Verify the ONT LEDs (DLP 119 ).
9 Activate and test the services (DLP 120 ).
10 STOP. This procedure is complete.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 121-5
NTP 121 — Install an I-241G-A indoor ONT
NTP 121-6 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 122 — Replace an I-241G-A indoor
ONT
Purpose
This NTP provides the steps to replace an I-241G-A indoor ONT.
General
The DLPs listed in this NTP describe mounting and cabling for the I-241G-A indoor ONT.
Prerequisites
See the listed DLPs for prerequisites.
Recommended tools
You need the following tools for replacing the ONT:
• #2 Phillips screwdriver
• 1/4 in. (6 mm) flat blade screwdriver
• wire strippers
• fiber optic splicing tools
• RJ-45 cable plug crimp tool
• voltmeter or multimeter
• optical power meter
• wall mounting template
• drill and drill bits
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 122-1
NTP 122 — Replace an I-241G-A indoor ONT
Safety information
Read the following safety information before installing the unit.
Danger 1 — Always contact the local utility company before you connect the enclosure to the utilities.
Danger 2 — Observe the local and national laws and regulations that may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections should be used when removing the fiber access cover of the indoor ONT.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged exposure to direct sunlight can damage the unit.
Note — Observe the following:
• The indoor ONT should be installed in accordance with the applicable requirements of the NEC or CEC. Local authorities and practices take precedent when there is conflict between the local standard and the NEC or CEC.
• The indoor ONT must be installed by qualified service personnel.
• Indoor ONTs must be installed with cables that are suitably rated and listed for indoor use.
Procedure
Use this procedure to replace an I-241G-A indoor ONT.
1 Deactivate the ONT services (DLP 123 ). If you are using the SLID feature, this step is not required. The ONT and the services can remain in service (IS).
2 At the subscriber site, locate the indoor ONT and disconnect the power, RF video, phone, Ethernet and fiber optic cables; see Figure
NTP 122-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 122 — Replace an I-241G-A indoor ONT
Figure NTP 122-1: Indoor ONT connections
2 1 1 2 3 4
PON
Video coaxial connector
RJ-11 phone connectors
Ethernet ports
Fiber optic port
Power connection
19397
3 Replace the indoor ONT with a new unit.
4 Connect the power, RF video, phone, and Ethernet connections to the ONT
(DLP 101 , DLP 105 , DLP 111 , and DLP 115 ).
5 Connect the power cable to the ac outlet.
6 If used, configure the SLID (DLP 121 ).
Note — A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at the P-OLT using TL1 or a network manager. If the old SLID is used, no changes need to be made at the P-OLT; see the appropriate P-OLT
Operations and Maintenance Procedures Guide for more details.
7 If required, have approved service personnel who are trained to work with optic fiber clean the fiber optic connection. See DLP 126 for more information about fiber optic handling, inspection, and cleaning.
Danger — Fiber optic cables transmit invisible laser light. To avoid eye damage or blindness, never look directly into fibers, connectors, or adapters.
8 Make the fiber optic connection using the fiber optic port shown in
Figure
.
Warning — Be careful to maintain a bend radius of no less than 1.5 inches (3.8 cm) when connecting the fiber optic cable. Too small of a bend radius in the cable can result in damage to the optic fiber.
9 Verify the ONT LEDs, voltage status, and optical signal levels (DLP 119 ).
10 Activate and test the services (DLP 120 ).
11 STOP. This procedure is complete.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 122-3
NTP 122 — Replace an I-241G-A indoor ONT
NTP 122-4 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 123 — Configure an I-241G-A indoor
ONT
General
Please refer to the OLT Operations and Maintenance using TL1 and CLI guide for the software configuration procedure for I-241G-A indoor ONTs.
For HTTP configuration procedures, please refer to chapter
5 , ONT management using an ONT interface
.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 123-1
NTP 123 — Configure an I-241G-A indoor ONT
NTP 123-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
I-240G-B, I-241G-B
14 — I-240G-B and I-241G-B unit data sheet
NTP 124 — Install an I-240G-B or I-241G-B indoor ONT
NTP 125 — Replace an I-240G-B or I-241G-B indoor ONT
NTP 126 — Configure an I-240G-B or I-241G-B indoor ONT
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
14 — I-240G-B and I-241G-B unit data sheet
14.1 I-240G-B and I-241G-B part numbers and identification 14-2
14.2 I-240G-B and I-241G-B general description 14-2
14.3 I-240G-B and I-241G-B software and installation feature support 14-3
14.4 I-240G-B and I-241G-B interfaces and interface capacity 14-4
14.5 I-240G-B and I-241G-B LEDs 14-5
14.6 I-240G-B and I-241G-B detailed specifications 14-6
14.7 I-240G-B and I-241G-B GEM ports and T-CONTs 14-7
14.8 I-240G-B and I-241G-B power support 14-8
14.9 I-240G-B and I-241G-B functional blocks 14-8
14.10 I-240G-B and I-241G-B standards compliance 14-9
14.11 I-240G-B and I-241G-B special considerations 14-9
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
14-1
14 — I-240G-B and I-241G-B unit data sheet
14.1
I-240G-B and I-241G-B part numbers and identification
Table 14-1 provides identification information about I-240G-B and I-241G-B indoor
ONTs.
Part number
3FE 51880 AB
3FE 51880 AA
Table 14-1 I-240G-B and I-241G-B part numbers and identification
Description
I-240G-B
I-241G-B
CLEI
GPON I-series ONT unit, version B, 2 POTS and 4 Ethernet interfaces.
GPON I-series ONT unit, version B, 2
POTS, 4 Ethernet, and 1 RF video interfaces.
—
—
CPR
—
—
ECI/Bar code
—
—
Note
(1) See Chapter
2 Part numbers, ordering, and deployment configuration overview
for ordering information.
14.2
I-240G-B and I-241G-B general description
I-240G-B and I-241G-B indoor ONTs provide a subscriber interface for the system.
The ONT terminates the PON interface and converts it to user interfaces that directly connect to subscriber devices. The ONT is compatible with all existing subscriber equipment, including analog phones with both tone and rotary dial capabilities, cordless phones, modems, fax machines, and caller ID boxes (Type I, Type II, and
Type III).
The I-240G-B and I-241G-B indoor ONTs are not temperature hardened. These
ONTs are intended for indoor deployment only and can be installed vertically or horizontally on a flat surface as well as attached to a wall.
These ONTs provide the following functions:
• network demarcation for all services
• voice interworking function from the analog POTS lines to the VoIP/Ethernet layers
• interworking functions between the GEM and Ethernet layers
• mux and demux functions to the PON
• optical to electrical conversion
• optics that support received signal strength indication (RSSI)
• G984.4 standard and revised compliant OMCI interface for ONT management and provisioning
14-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
14 — I-240G-B and I-241G-B unit data sheet
Other features of I-240G-B and I-241G-B indoor ONTs include:
• a removable fiber access tray for storing excess cable
• an ON/OFF power switch for manual shut down when needed
• a reset button located on the base of the ONT
Note — The maximum supported capacity for downstream data traffic for the I-240G-B indoor ONT is 1 Gb/s. This supported capacity is constant whether one or more Ethernet ports are used. If you use one Ethernet port, the entire 1 Gb/s throughput travels on that port, while, if you use two or more Ethernet ports, the 1 Gb/s capacity is divided among the ports.
14.3
I-240G-B and I-241G-B software and installation feature support
Table
14-2 provides a list of software-based features for I-240G-B and I-241G-B
indoor ONTs.
Table 14-2 I-240G-B and I-241G-B indoor ONT software feature support
Features
General ONT and MDU overview
Service interface specifications
Services supported
Chapter
ONT and MDU general and interface technical specifications
—
Cross reference for more information
ONT and MDU general descriptions of features and functions
Ethernet interface specifications
•
Coaxial connectivity in the home and design guidelines
•
See the appropriate P-OLT user documentation for service creation procedures and descriptions.
RSSI specifications
Wi-Fi specifications
Optical budget
Location and installation options
HTTP management
Statistics and performance monitoring
Supported UPS configurations
ONT and MDU general and interface technical specifications
—
ONT and MDU general and interface technical specifications
How to install, replace, and configure an I-240G-B or I-241G-B ONT
—
ONT and MDU statistics and performance monitoring
Part numbers, ordering, and deployment configuration overview
—
Install an I-240G-B or I-241G-B indoor ONT
Replace an I-240G-B or I-241G-B indoor ONT
ONT management using an ONT interface
Supported performance monitoring counters per package type of ONT
ONT and MDU to UPS or power adapter compatibility support
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
14-3
14 — I-240G-B and I-241G-B unit data sheet
14.4
I-240G-B and I-241G-B interfaces and interface capacity
Table
14-3 describes the supported interfaces for I-240G-B and I-241G-B indoor
ONTs.
Table 14-3 I-240G-B and I-241G-B indoor ONT interfaces
ONT category description
Single-residence Gigabit
Ethernet ONTs with or without
POTS and RF video (I-240G-B and I-241G-B indoor ONTs)
Interface capacity
POTS ports
2
Ethernet ports
4
VDSL2 interfaces
0
MoCA interface
0
RF Video interface
0/1
14-4
I-240G-B and I-241G-B connections and components
Figures
show the I-240G-B and I-241G-B indoor ONT physical connections.
Figure 14-1 I-240G-B indoor ONT connections
Power connector
U
S
B
1
2
POTS1 POTS2 LAN1 LAN2 LAN3 LAN4
POWER Fiber optic connector
Phone connectors
(RJ-11)
Ethernet ports
(RJ-45)
On/off
21342
Figure 14-2 I-241G-B indoor ONT connections
Power connector
TV
U
S
B
1
2
POTS1 POTS2 LAN1 LAN2 LAN3 LAN4
POWER Fiber optic connector
RF video coaxial connector
Phone connectors
(RJ-11)
Ethernet ports
(RJ-45)
On/off
20429
Table
14-4 describes the I-240G-B indoor ONT physical connections.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
14 — I-240G-B and I-241G-B unit data sheet
Table 14-4 I-240G-B, and I-241G-B indoor ONT physical connections
Connection
POTS
Ethernet ports
Power
Fiber optic
Description
This connection is provided through RJ-11 ports.
This connection is provided through Ethernet RJ-45 cables. Four
Ethernet connections are supported.The Ethernet ports can support both data and in-band video services on all four interfaces.
This connection is provided through a power cable with a Molex connector to the power connector.
This connection is provided through a SC/APC fiber optic cable and connector.
I-241G-B indoor ONT only
RF video coaxial This connection is provided through a Type F coaxial connector.
14.5
I-240G-B and I-241G-B LEDs
shows the I-240G-B and I-241G-B indoor ONT LEDs.
Figure 14-3 I-240G-B and I-241G-B indoor ONT LEDs
VIDEO
ALARM
PO
WER
WA
N
LAN
LAN 2
LAN 3
LAN 4
20425
Table
14-5 lists and describes the I-240G-B and I-241G-B indoor ONT LEDs.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
14-5
14 — I-240G-B and I-241G-B unit data sheet
Table 14-5 I-240G-B and I-241G-B indoor ONT LEDs descriptions
Indicator
POWER
WAN
ALARM
LED color and behavior
Off
Green
Green flashing
Red
Green
Green flashing
Red
Orange
Orange flashing
Off
Red
Red flashing
LAN 1 to 4
VOICE
Off
Green
Green flashing
Orange/Red flashing
Orange
Off
Green solid
I-241G-B indoor ONT only
VIDEO Off
Red
LED behavior description
No power
Operating on ac power
ONT is starting up
Operating on battery backup power
PON is connected and operating properly
Software downloading
PON not connected but ONT has power
ONT ranged but OMCI not established
ONT is ranging
ONT is operating without failure
ONT operation failure (not ranged)
ONT software failure
Not provisioned or no Ethernet connection
10/100 link detected
10/100 link has data activity
1000 link has data activity
1000 link detected
No POTS provisioned (all phones are on-hook or no phones connected)
One or more phones is off-hook
Normal operation
Service provisioned and optical power too low
Indicator
LINK
MODE
lists and describes the I-240G-B and I-241G-B indoor ONT RJ-45 LEDs.
Table 14-6 I-240G-B and I-241G-B Indoor ONT RJ-45 LEDs
LED color and behavior
Off
Green solid
Green flashing
Off
Green solid
LED behavior description
Link not detected
Link active
Link detected and activity present
10 and 100 Mb/s operation
1000 Mb/s operation
14.6
I-240G-B and I-241G-B detailed specifications
Table
14-7 lists the physical specifications for I-240G-B and I-241G-B indoor
ONTs.
14-6 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
14 — I-240G-B and I-241G-B unit data sheet
Table 14-7 I-240G-B and I-241G-B indoor ONT physical specifications
Dimensions
Height
Width
Depth (excluding fiber storage tray)
Weight [within ± 0.5 lb (0.23 kg)]
Specifications
5.4 in. (13.7 cm)
4 in. (10.2 cm)
1.3 in. (3.3 cm)
1.25 lb (0.57 kg)
Table
14-8 lists power consumption specifications for I-240G-B and I-241G-B
indoor ONTs.
Mnemonic
I-240G-B
I-241G-B
Table 14-8 I-240G-B and I-241G-B indoor ONT power consumption specifications
Maximum power
(not to exceed)
7.75 W
Condition
2 POTS off-hook, 4 Gig-E operational
10 W 2 POTS off-hook, 4 Gig-E,
Video operational
Minimum power Condition
4.75 W
4.75 W
2 POTS on-hook, other interfaces/services not provisioned
2 POTS on-hook, other interfaces/services not provisioned
Table 14-9 lists the environmental requirements for I-240G-B and I-241G-B indoor
ONTs.
Table 14-9 I-240G-B and I-241G-B indoor ONT environmental requirements
ONT type
Mounting method
Desk or wall mounted
Temperature range and humidity
Operating:
32 ° F to 104 ° F (0 ° C to 40 ° C) ambient temperature
5% to 85% relative humidity, non-condensing
Maximum rate of temperature change is 32.9
° F (0.5
° C) per hour
Storage:
-13 ° F to 133 ° F (-25 ° C to 55 ° C)
5% to 93% relative humidity, non-condensing
Altitude
Maximum operating altitude is
10 000 ft (3048 m) above mean sea level
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea level
14.7
I-240G-B and I-241G-B GEM ports and T-CONTs
Table
lists the maximum number of supported T-CONTs and GEM ports for
I-240G-B and I-241G-B indoor ONTs. Not all ONTs will be supported in all of the releases indicated the table. See the appropriate release Customer Release Notes for the most accurate list of supported devices.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
14-7
14 — I-240G-B and I-241G-B unit data sheet
Table 14-10 I-240G-P and I-241G-B indoor ONT capacity for GEM ports and T-CONTs per package and release
Maximum Notes ONT or MDU
Package B ONTs
GEM ports per indoor or outdoor ONT
Release
All
T-CONTs per indoor or outdoor ONT
All
30
31
32 are present: 30 are available, 2 are reserved for multicast and debugging
32 are present: 31 are available, 1 is reserved for OMCI
14.8
14.9
I-240G-B and I-241G-B power support
The following power supplies support the I-240G-B and I-241G-B indoor ONTs.
Click on the link for more information.
• Delta DUPS-1215 UPS unit data sheet
• Emerson 24 W AC/DC switching power adapter unit data sheet
I-240G-B and I-241G-B functional blocks
POTS and RF video ports may or may not be available in addition to Ethernet ports.
These ONTs transmit Ethernet packets to four RJ-45 Ethernet ports, and voice traffic to two RJ-11 POTS ports and RF video traffic to one F-type coaxial connector. These
ONTs also feature fiber optic and power connectors.
shows the functional blocks for an indoor ONT with Gigabit Ethernet,
POTS, and coaxial ports. For those ONTs with less than the maximum number of
Gigabit Ethernet or POTS ports, the excess ports are blocked by a plastic cover.
Figure 14-4 Single-residence Gigabit Ethernet ONT with POTS and RF video
GPON
Optical block
SOC
RF Video
Amp
Power Converter
POTS (2/1/0)
Ethernet (4/1)
Diplexer
Power connector
RJ-11
RJ-45
F-type connector
20417
14-8 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
14 — I-240G-B and I-241G-B unit data sheet
14.10
I-240G-B and I-241G-B standards compliance
I-240G-B and I-241G-B indoor ONTs are compliant with the following standards:
• 802.1p mapper service profile on the upstream
• G.984 support for GPON interface (framing)
• G.984.3 support for activation with automatic discovery of a serial number and a password
• G984.4 (standard and revised) support for OMCI interface for ONT management and provisioning
14.11
I-240G-B and I-241G-B special considerations
IGMP packet replication allows the I-240G-B and I-241G-B indoor ONTs to support
IPTV on all four Ethernet channels at the same time.
On a user-side port in flexible mode, downstream multicast traffic will have the
UNI-side p-bit of the parameter DATAPRI configured for the IGMP signaling channel, unless the DATAPRI value differs between ONT UNIs. In the latter case, the downstream multicast traffic will retain the p-bit from the PON. On a user-side port in non-flexible mode, such as translation mode, downstream multicast traffic will retain the p-bit from the PON. The multicast VLAN ID may differ; see
Table
for tagging behavior.
Table 14-11 Multicast downstream VLAN tagging for I-240G-B and I-241G-B indoor ONTs
Port configuration
One port configured in flexible mode or VLAN translation mode with a configured IGMP signaling channel
More than one port configured in flexible mode or VLAN translation mode each with a configured IGMP signaling channel
VLAN tagging of downstream multicast traffic
Multicast traffic is tagged with UNI-side VLAN ID of
IGMP-related service.
If the IGMP-related services are configured with the same
UNI-side VLAN ID, then all multicast traffic is tagged with the UNI-side VLAN ID of their service.
If the IGMP-related services are configured with different
UNI-side VLAN IDs, then all multicast traffic is tagged with
VLAN ID 4094.
The multicast traffic is tagged with VLAN ID 4094.
More than one port configured in VLAN pass-through mode, untrusted mode, EtherType/VLAN translation mode, or
EtherType classification mode with some ports in transmit with tag and other ports in transmit without a tag, and each port with a configured IGMP signaling channel
All other cases The multicast traffic retains the VLAN ID from the PON.
Note
(1) You can only have one IGMP signaling channel on a port.
Service creation considerations and limitations
Port-to-port mode must be enabled when using four-port Ethernet ONTs I-240G-B and I-241G-B. When using port-to-port mode, you can only configure one Ethernet port.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
14-9
14 — I-240G-B and I-241G-B unit data sheet
Upgrade considerations and limitations
Existing ONTs that use 7342 ISAM FTTU releases older than R04.06.xx and
R04.07.xx must be upgraded to use R04.00.10 software while assigned to a PON ID value smaller than 64. For this purpose, if split ratios larger than 1:64 are being deployed, you may choose to set aside the first PON ID as a staging point.
I-240G-B and I-241G-B ONT considerations and limitations
Table
lists the considerations and limitations for these ONTs.
Table 14-12 I-240G-B and I-241G-B ONT considerations and limitations
Considerations and limitations
When using multicast on multiple Ethernet ports, all Ethernet ports must have the same VLAN ID. If the user-side VLAN IDs are all given the same VLAN ID, a common VLAN ID should result. If not, VLAN
4094 will be used
ONTs are not able to sufficiently buffer enough traffic between grants to support an EIR rate of
1Gb/s over multiple GEM ports. There are only 1.256 Gb/s buffers available in the SoC chip. The buffers are divided among the number of configured GEM ports. Reducing the number of GEM ports configured results in increased upstream buffering and higher upstream traffic rates.
Packets of less than 64 bytes are increased to 100 bytes in size with padding under the following conditions:
• in a downstream direction
• in an upstream direction only if the ONT has more than 2 Ethernet ports
ONTs that use pre R04.00.10 software may not range if the distance from the LT card is less than 1km
14-10 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 124 — Install an I-240G-B or
I-241G-B indoor ONT
Purpose
This NTP provides the steps to install an I-240G-B or I-241G-B indoor ONT.
General
The DLPs listed in this NTP describe mounting and cabling for the I-240G-B and I-241G-B indoor ONT.
Prerequisites
See the listed DLPs for prerequisites.
Recommended tools
You need the following tools for the installation:
• #2 Phillips screwdriver
• 1/4 in. (6 mm) flat blade screwdriver
• wire strippers
• fiber optic splicing tools
• RJ-45 cable plug crimp tool
• voltmeter or multimeter
• optical power meter
• wall mounting template
• Fair-Rite 0431164281 (1AB 09397 0031) ferrite core shipped with the ONT
• drill and drill bits
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 124-1
NTP 124 — Install an I-240G-B or I-241G-B indoor ONT
Safety information
Read the following safety information before installing the unit.
Danger 1 — Contact the local utility company before you connect the enclosure to the utilities.
Danger 2 — Observe the local and national laws and regulations that may be applicable to this installation.
Danger 3 — If the coaxial output of the ONT is connected to the dwelling infrastructure coaxial distribution system, ensure that the coaxial distribution system is separately grounded. Grounding of the dwelling coaxial infrastructure shall use Listed grounding devices and must be installed in accordance with local Codes and Article 800 of the
National Electric Code, ANSI/NFPA 70, following the manufacturers instructions.
Warning 1 — This equipment is ESD sensitive. Proper ESD protections should be used when removing the fiber access cover of the indoor ONT.
Warning 2 — Installation of the supplied ferrite on the Ethernet cable is required for EMC compliance. Failure to install the supplied ferrite core may cause interference with TV or radio reception. Alcatel-Lucent is not responsible for any radio or television interference caused by using other than the supplied ferrite core or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to operate this equipment.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged exposure to direct sunlight can damage the unit.
Note — Observe the following:
• The indoor ONT should be installed in accordance with the applicable requirements of the NEC or CEC. Local authorities and practices take precedent when there is conflict between the local standard and the NEC or CEC.
• The indoor ONT must be installed by qualified service personnel.
• Indoor ONTs must be installed with cables that are suitably rated and listed for indoor use.
•
See I-240G-B and I-241G-B detailed specifications
in the I-240G-B and I-241G-B unit data sheet for the temperature ranges for ONTs.
NTP 124-2 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 124 — Install an I-240G-B or I-241G-B indoor ONT
Procedure
Use this procedure to install an I-240G-B or I-241G-B indoor ONT.
1 Prepare the cables at the site where the ONT will be installed (DLP 100 ).
2 Are any of the cables missing?
a
b
3 Locate each missing cable and route them to the ONT as per local practices.
4 Place the indoor ONT unit: a On the flat surface, such as a desk, horizontally resting on its four feet as shown in Figure
Figure NTP 124-1: I-240G-B or I-241G-B indoor ONT on a desk
ALARM
PO
WER
WA
N
LAN 1
LAN 2
LAN 3
LAN 4
VOICE
VIDEO
20430 b In the stand mount.
i Place the stand mount on the flat surface.
ii Place the ONT into the opening on the stand mount, ensuring it is securely held. Figure
shows the stand mount.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 124-3
NTP 124 — Install an I-240G-B or I-241G-B indoor ONT
Figure NTP 124-2: I-240G-B or I-241G-B indoor ONT in a stand mount
NTP 124-4
VIDEO
VOICE
LAN 4
LAN 3
LAN 2
LAN 1
ALARM
WA
N
PO
WER
20431 iii Go to step
.
c On a wall (DLP 114 ).
5
Review the connection locations shown in Figures NTP 124-3
and
.
Figure NTP 124-3: I-240G-B indoor ONT connections
Power connector
U
S
B
1
2
POTS1 POTS2 LAN1 LAN2 LAN3 LAN4 POWER Fiber optic connector
Phone connectors
(RJ-11)
Ethernet ports
(RJ-45)
On/off
21342
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 124 — Install an I-240G-B or I-241G-B indoor ONT
Figure NTP 124-4: I-241G-B indoor ONT connections
Power connector
TV
U
S
B
1
2
POTS1 POTS2 LAN1 LAN2 LAN3 LAN4
POWER Fiber optic connector
RF video coaxial connector
Phone connectors
(RJ-11)
Ethernet ports
(RJ-45)
On/off
6 Connect the Ethernet cables to the RJ-45 ports (DLP 101 ).
7 Connect the POTS cables (DLP 115 ).
8 Connect the SC/APC fiber optic cable (DLP 117 ).
20429
Warning — Be careful to maintain a bend radius of no less than 1.5 inches (3.8 cm) when connecting the fiber optic cable. Too small of a bend radius in the cable can result in damage to the optic fiber.
9 Install the power supply according to manufacturer specifications.
Note — Observe the following:
• Units must be powered by a Listed or CE approved and marked limited power source power supply with a minimum output rate of
12 V dc, 1.25 A.
10 Connect the power cable with an 8-pin Molex connector to the ONT unit.
11 Power up the ONT unit by using the ON/OFF power switch.
12 If necessary, reset the ONT (DLP 118 ).
13 Verify the ONT LEDs, voltage status, and optical signal levels (DLP 119 ).
14 Activate and test the services (DLP 120 ).
15 If used, configure the SLID (DLP 121 ).
16 STOP. This procedure is complete.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 124-5
NTP 124 — Install an I-240G-B or I-241G-B indoor ONT
NTP 124-6 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 125 — Replace an I-240G-B or
I-241G-B indoor ONT
Purpose
This NTP provides the steps to replace an I-240G-B or I-241G-B indoor ONT.
General
The DLPs listed in this NTP describe mounting and cabling for the I-240G-B or I-241G-B indoor ONT.
Prerequisites
See the listed DLPs for prerequisites.
Recommended tools
You need the following tools for replacing the ONT:
• #2 Phillips screwdriver
• 1/4 in. (6 mm) flat blade screwdriver
• wire strippers
• fiber optic splicing tools
• RJ-45 cable plug crimp tool
• voltmeter or multimeter
• optical power meter
• wall mounting template
• Fair-Rite 0431164281 (1AB 09397 0031) ferrite core shipped with the ONT
• drill and drill bits
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 125-1
NTP 125 — Replace an I-240G-B or I-241G-B indoor ONT
Safety information
Read the following safety information before replacing the unit.
Danger 1 — Contact the local utility company before you connect the enclosure to the utilities.
Danger 2 — Observe the local and national laws and regulations that may be applicable to this installation.
Danger 3 — If the coaxial output of the ONT is connected to the dwelling infrastructure coaxial distribution system, ensure that the coaxial distribution system is separately grounded. Grounding of the dwelling coaxial infrastructure shall use Listed grounding devices and must be installed in accordance with local Codes and Article 800 of the
National Electric Code, ANSI/NFPA 70, following the manufacturers instructions.
Warning 1 — This equipment is ESD sensitive. Proper ESD protections should be used when removing the fiber access cover of the indoor ONT.
Warning 2 — Installation of the supplied ferrite on the Ethernet cable is required for EMC compliance. Failure to install the supplied ferrite core may cause interference with TV or radio reception. Alcatel-Lucent is not responsible for any radio or television interference caused by using other than the supplied ferrite core or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to operate this equipment.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged exposure to direct sunlight can damage the unit.
NTP 125-2
Note — Observe the following:
• The indoor ONT should be installed in accordance with the applicable requirements of the NEC or CEC. Local authorities and practices take precedent when there is conflict between the local standard and the NEC or CEC.
• The indoor ONT must be installed by qualified service personnel.
• Indoor ONTs must be installed with cables that are suitably rated and listed for indoor use.
•
See I-240G-B and I-241G-B detailed specifications
in the I-240G-B and I-241G-B unit data sheet for the temperature ranges for ONTs.
Procedure
Use this procedure to replace an I-240G-B or I-241G-B indoor ONT.
1 Deactivate the ONT services (DLP 123 ). If you are using the SLID feature, this step is not required. The ONT and the services can remain in service (IS).
2 Power down the ONT unit by using the ON/OFF power switch.
December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 125 — Replace an I-240G-B or I-241G-B indoor ONT
3 Disconnect the POTS, Ethernet, coaxial, and power cables from the ONT
(DLP 124
); see Figures NTP 125-1 and NTP 125-2
.
Figure NTP 125-1: I-240G-B indoor ONT connections
Power connector
U
S
B
1
2
POTS1 POTS2 LAN1 LAN2 LAN3 LAN4
POWER Fiber optic connector
Phone connectors
(RJ-11)
Ethernet ports
(RJ-45)
On/off
21342
Figure NTP 125-2: I-241G-B indoor ONT connections
Power connector
TV
U
S
B
1
2
POTS1 POTS2 LAN1 LAN2 LAN3 LAN4
POWER Fiber optic connector
RF video coaxial connector
Phone connectors
(RJ-11)
Ethernet ports
(RJ-45)
On/off
20429
4 Disconnect the SC/APC adaptor from the fiber optic connector on the ONT
(DLP 125
); see Figures NTP 125-1 and NTP 125-2
.
5 Replace the ONT with a new unit: a On a flat surface, such as a desk, substitute a replacement ONT for the old
b In a stand.
i Unsnap the old ONT from the channels built into the stand. Snap the new ONT into channels built into the stand, ensuring it is securely held. ii Place the replacement ONT with stand vertically on a flat surface; go to step
. c On a wall.
i Slide the old ONT upward and then away from the two mounting screws until the ONT is free of the wall.
ii Slide the wall mount keyholes on the ONT enclosure or fiber storage tray of the replacement ONT down over the mounting screws until it is securely seated.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 125-3
NTP 125 — Replace an I-240G-B or I-241G-B indoor ONT
6 Connect the Ethernet cables (DLP 101 ).
7 Connect the POTS cables (DLP 115 ).
8 If required, have approved service personnel who are trained to work with optic fiber clean the fiber optic connection. See DLP 126 for more information about fiber optic handling, inspection, and cleaning.
Danger — Fiber optic cables transmit invisible laser light. To avoid eye damage or blindness, never look directly into fibers, connectors, or adapters.
9 Connect the SC/APC fiber optic cable (DLP 117 ).
Warning — Be careful to maintain a bend radius of no less than 1.5 inches (3.8 cm) when connecting the fiber optic cable. Too small of a bend radius in the cable can result in damage to the optic fiber.
10 Install the power supply according to manufacturer specifications.
Note — Observe the following:
• Units must be powered by a Listed or CE approved and marked limited power source power supply with a minimum output rate of
12 V dc, 1.25 A.
11 Connect the power cable with an 8-pin Molex connector to the ONT unit.
12 Power up the ONT unit by using the ON/OFF power switch.
13 If necessary, reset the ONT (DLP 118 ).
14 If used, configure the SLID (DLP 121 ).
Note — A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at the P-OLT using TL1 or a network manager. If the old SLID is used, no changes need to be made at the P-OLT; see the operations and maintenance documentation for the OLT for more details.
15 Verify the ONT LEDs, voltage status, and optical signal levels (DLP 119 ).
16 Activate and test the services (DLP 120 ).
17 STOP. This procedure is complete.
NTP 125-4 December 2010 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
ONT Product Information Guide Edition 01 3FE 54017 AAAA TCZZA
NTP 126 — Configure an I-240G-B or
I-241G-B indoor ONT
General
Please refer to the OLT Operations and Maintenance using TL1 and CLI guide for the software configuration procedure for an I-240G-B or I-241G-B indoor ONT.
For HTTP configuration procedures, please refer to chapter
5 , “ONT management using an ONT interface” .
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
December 2010
3FE 54017 AAAA TCZZA Edition 01 ONT Product Information Guide
NTP 126-1