Panasonic GT01 Flat Panel Television User manual

Add to My manuals
181 Pages

advertisement

Panasonic GT01 Flat Panel Television User manual | Manualzz

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Safety Precautions

Observe the following notices to ensure personal safety or to prevent accidents.

To ensure that you use this product correctly, read this User’s Manual thoroughly before use.

Make sure that you fully understand the product and information on safety.

This manual uses two safety flags to indicate different levels of danger.

WARNING

If critical situations that could lead to user’s death or serious injury is assumed by mishandling of the product:

- Always take precautions to ensure the overall safety of your system, so that the whole system remains safe in the event of failure of this product or other external factor.

- DO NOT USE THE PROGRAMMABLE DISPLAY TO CONTROL SAFETY FEATURES OR

OTHER CRITICAL OPERATIONS OF EQUIPMENT OR SYSTEMS. A COMMUNICATION

ERROR (FOR ANY REASON) MIGHT PREVENT SUCH SAFETY FEATURES OR

CRITICAL OPERATIONS FROM FUNCTIONING PROPERLY.

- Do not use this product in areas with inflammable gas. It could lead to an explosion.

- Exposing this product to excessive heat or open flames could cause damage to the lithium battery or other electronic parts.

- Battery may explode if mistreated. Do not recharge, disassemble or dispose of fire.

CAUTION

If critical situations that could lead to user’s injury or only property damage is assumed by mishandling of the product.

- To prevent excessive exothermic heat or smoke generation, use this product at the values less than the maximum of the characteristics and performance that are assured in these specifications.

- Do not dismantle or remodel the product. It could cause excessive exothermic heat or smoke generation.

- Do not touch the terminal while turning on electricity. It could lead to an electric shock.

- Use the external devices to function the emergency stop and interlock circuit.

- Connect the wires or connectors securely.

The loose connection could cause excessive exothermic heat or smoke generation.

- Do not allow foreign matters such as liquid, flammable materials, metals to go into the inside of the product. It could cause excessive exothermic heat or smoke generation.

- Do not undertake construction (such as connection and disconnection) while the power supply is on. It could lead to an electric shock.

- The control force of the touch switches should be less than the specification of the product.

Failure to do so could lead to a damage to the product or a personal injury.

- These touch switches operate using analog resistance membrane. Do not press more than one point on the screen at a time. Doing so might operate a switch located in the middle of the points pressed if one exists, and could lead to a damage to the facility or an accident.

Copyright / Trademarks

- This manual and its contents are copyrighted.

- You may not copy this manual in whole or part, without written consent of Panasonic Electric

Works SUNX Co., Ltd.

- Windows is a registered trademark of Microsoft Corporation in the United States and other countries.

- Ethernet is a registered trademark of Fuji Xerox Co., Ltd. and Xerox Corp.

- SDHC logo and SD logo are trademarks.

- All other company names and product names are trademarks or registered trademarks of their respective owners.

POT_GT

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Table of Contents

Before You Start

Manual to be Used

Available Functions and GT Versions

Chapter 1 Features and Functions ............................................................ 1-1

1.1 Features and Functions of GT Series ............................................................................ 1-2

1.2 Types of Units .................................................................................................................. 1-7

1.2.1 GT Series .................................................................................................................... 1-7

1.2.2 Options and Repair Parts ............................................................................................ 1-9

1.3 Screen Creation Tool .................................................................................................... 1-12

1.3.1 Tools Required for Screen Creation ......................................................................... 1-12

1.3.2 Software Usage Environment and Applicable Cables .............................................. 1-12

Chapter 2 Names and Functions of Parts ................................................. 2-1

2.1 Part Names ....................................................................................................................... 2-2

2.1.1 GT01, GT11 and GT21 ............................................................................................... 2-2

2.1.2 GT02/GT02L ............................................................................................................... 2-4

2.1.3 GT05/GT12/GT32 ....................................................................................................... 2-6

2.2 Terminal Layouts of COM Port ....................................................................................... 2-8

2.2.1 GT01 ........................................................................................................................... 2-8

2.2.2 GT02 ........................................................................................................................... 2-9

2.2.3 GT02L ....................................................................................................................... 2-10

2.2.4 GT11/GT12 ............................................................................................................... 2-11

2.2.5 GT21 ......................................................................................................................... 2-12

2.2.6 GT05/GT32/GT32-E ................................................................................................. 2-13

2.3 Connecting to Screen Creation Tool GTWIN .............................................................. 2-14

2.3.1 TOOL Port ................................................................................................................. 2-14

2.3.2 USB Port ................................................................................................................... 2-14

2.3.3 Ethernet Port ............................................................................................................. 2-15

Chapter 3 Installation and Wiring .............................................................. 3-1

3.1 Installation ........................................................................................................................ 3-2

3.1.1 Installation Environment .............................................................................................. 3-2

3.1.2 Restriction According to Mounting Directions ............................................................. 3-4

3.1.3 Installation Space ........................................................................................................ 3-4

3.1.4 UL/c-UL Qualification .................................................................................................. 3-4

3.1.5 Mounting Screws ........................................................................................................ 3-5

3.1.6 GT01 and GT11 Installation Method ........................................................................... 3-6

3.1.7 GT21 Installation Method ............................................................................................ 3-6

3.1.8 GT05/GT32/GT32-E Installation Method .................................................................... 3-7

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.1.9 GT02/GT02L/GT12 Installation Method ...................................................................... 3-8

3.1.10 Installing in Vertical Orientation ................................................................................ 3-9

3.1.11 Precaution When reinstalling GT .............................................................................. 3-9

3.2 Wiring the Power Supply .............................................................................................. 3-10

3.2.1 Wiring the Power supply ........................................................................................... 3-10

3.2.2 Grounding ................................................................................................................. 3-11

3.3 Wiring the COM Port ...................................................................................................... 3-12

3.4 Precautions when Wiring COM Port ............................................................................ 3-14

3.4.1 GT01 (5 V DC) .......................................................................................................... 3-14

3.4.2 GT02/GT02L (5 V DC) .............................................................................................. 3-15

3.4.3 RS232C Communication ........................................................................................... 3-16

3.4.4 RS422 (RS485) Communication ............................................................................... 3-17

3.5 Precautions when Wiring Ethernet Port (GT32T1) ..................................................... 3-18

3.6 Options ........................................................................................................................... 3-19

3.6.1 Backup Battery .......................................................................................................... 3-19

3.6.2 How to Install the Battery (Lithium Button Battery) ................................................... 3-20

3.6.3 How to Install the Battery (Backup Battery) .............................................................. 3-20

3.6.4 Dead Battery Mark .................................................................................................... 3-21

3.6.5 Time for Replacement of Battery .............................................................................. 3-21

3.6.6 Replacement of Front Panel Protective Sheet .......................................................... 3-21

3.6.7 About the Waterproof Packing .................................................................................. 3-22

Chapter 4 Connecting with PLC ................................................................ 4-1

4.1 Connection with PLC ....................................................................................................... 4-2

4.1.1 PLC Multiple Connection ............................................................................................. 4-2

4.1.2 GT Link Connection .................................................................................................... 4-2

4.1.3 Connecting to the PLCs made by Other Companies .................................................. 4-3

4.1.4 Connecting to a Serial Device ..................................................................................... 4-3

4.1.5 Electric Supply from PLC (5 V DC-type ) .................................................................... 4-3

4.2 RS232C Connection ........................................................................................................ 4-4

4.2.1 Difference of Terminal blocks Between GT Models .................................................... 4-4

4.2.2 RS232C Connection with PLC Tool Port .................................................................... 4-5

4.2.3 RS232C Connection with FP-X COM Port .................................................................. 4-7

4.2.4 RS232C Connection with FP COM Port ................................................................... 4-9

4.2.5 RS232C Connection with FP0/FP0R COM Port ....................................................... 4-11

4.2.6 RS232C Connection with FP-e COM Port ................................................................ 4-12

4.2.7 RS232C Connection with FP2/FP2SH COM Port .................................................... 4-13

4.3 RS422 Connection ......................................................................................................... 4-14

4.3.1 Difference of Terminal blocks Between GT Models .................................................. 4-14

4.3.2 RS422 Connection with FP-X COM Port .................................................................. 4-15

4.3.3 RS422 Connection with FP2/FP2SH COM Port ....................................................... 4-16

4.3.4 RS422 Connection with C-NET Adapter ................................................................... 4-17

4.4 RS485 Connection ......................................................................................................... 4-18

ii

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.4.1 Difference of Terminal blocks Between GT Models .................................................. 4-18

4.4.2 RS485 Connection with FP0R COM Port ................................................................. 4-19

4.4.3 RS485 Connection with FP-X COM Port .................................................................. 4-20

4.4.4 RS485 Connection with FPΣ COM Port.................................................................... 4-23

4.4.5 RS485 Connection with FP-e COM Port .................................................................. 4-25

4.4.6 RS485Connection with FP2/FP2SH ......................................................................... 4-26

4.4.7 Precautions When Communicating With RS485 ...................................................... 4-27

4.5 Connection With a PLC ................................................................................................. 4-28

4.5.1 Automatic Communication Settings Function ........................................................... 4-28

4.5.2 Through Function ...................................................................................................... 4-29

4.5.3 How to Make Communication Settings Using the FPWIN GR ................................. 4-31

Chapter 5 Troubleshooting ........................................................................ 5-1

5.1 What to DO If Something Unusual Occurs (GT01/GT11/ GT21) .................................. 5-2

5.2 What to DO If Something Unusual Occurs (GT02/GT02L/GT05/GT12/GT32)............. 5-5

5.3 Error Codes and How to Handle Them ........................................................................ 5-10

5.3.1 About Error Codes .................................................................................................... 5-10

5.3.2 GT Series Error Codes ............................................................................................. 5-10

5.3.3 When Connected to a FP Series PLC ...................................................................... 5-13

5.3.4 When Connected to a PLC (FX Series) Made by Mitsubishi Electric Corporation ... 5-15

5.3.5 When Connected to a PLC Made by Omron Corporation ........................................ 5-16

5.3.6 When Connected to Modbus .................................................................................... 5-17

5.3.7 When Connected to a PLC Made by Toshiba Machine Co., Ltd. ............................. 5-17

5.3.8 When Performing General-purpose Serial Communication ..................................... 5-18

Chapter 6 Specifications ............................................................................ 6-1

6.1 GT01 .................................................................................................................................. 6-2

6.1.1 General Specifications ................................................................................................ 6-2

6.1.2 Performance Specifications (GT01) ............................................................................ 6-3

6.1.3 Function Specifications (GT01) ................................................................................... 6-4

6.1.4 Interface Specifications (GT01) .................................................................................. 6-5

6.2 GT02 .................................................................................................................................. 6-6

6.2.1 General Specifications (GT02) .................................................................................... 6-6

6.2.2 Performance Specifications (GT02) ............................................................................ 6-7

6.2.3 Function Specifications (GT02) ................................................................................... 6-8

6.2.4 Interface Specifications (GT02) .................................................................................. 6-9

6.3 GT02L .............................................................................................................................. 6-10

6.3.1 General Specifications (GT02L) ................................................................................ 6-10

6.3.2 Performance Specifications (GT02L) ........................................................................ 6-11

6.3.3 Function Specifications (GT02L) ............................................................................... 6-12

6.3.4 Interface Specifications (GT02L) .............................................................................. 6-13

6.4 GT05 ................................................................................................................................ 6-14

6.4.1 General Specifications .............................................................................................. 6-14

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.4.2 Performance Specifications (GT05) .......................................................................... 6-15

6.4.3 Function Specifications (GT05) ................................................................................. 6-16

6.4.4 Interface Specifications (GT05) ................................................................................ 6-17

6.5 GT11 ................................................................................................................................ 6-18

6.5.1 General Specifications (GT11) .................................................................................. 6-18

6.5.2 Performance Specifications (GT11) .......................................................................... 6-19

6.5.3 Function Specifications (GT11) ................................................................................. 6-20

6.5.4 Interface Specifications (GT11) ................................................................................ 6-21

6.6 GT12 ................................................................................................................................ 6-22

6.6.1 General Specifications (GT12) .................................................................................. 6-22

6.6.2 Performance Specifications (GT12) .......................................................................... 6-23

6.6.3 Function Specifications (GT12) ................................................................................. 6-24

6.6.4 Interface Specifications (GT12) ................................................................................ 6-25

6.7 GT21 ................................................................................................................................ 6-26

6.7.1 General Specifications (GT21) .................................................................................. 6-26

6.7.2 Performance Specifications (GT21) .......................................................................... 6-27

6.7.3 Function Specifications (GT21) ................................................................................. 6-28

6.7.4 Interface Specifications (GT21) ................................................................................ 6-29

6.8 GT32 ................................................................................................................................ 6-30

6.8.1 General Specifications (GT32) .................................................................................. 6-30

6.8.2 Performance Specifications (GT32) .......................................................................... 6-31

6.8.3 Function Specifications (GT32) ................................................................................. 6-32

6.8.4 Interface Specifications (GT32) ................................................................................ 6-33

6.8.5 Sound Output Specifications (GT32T1 Only)............................................................ 6-34

6.9 GT32-E ............................................................................................................................ 6-35

6.9.1 General Specifications (GT32-E) .............................................................................. 6-35

6.9.2 Performance Specifications (GT32-E) ...................................................................... 6-36

6.9.3 Function Specifications (GT32-E) ............................................................................. 6-37

6.9.4 Interface Specifications (GT32-E) ............................................................................. 6-38

Chapter 7 Dimensions and Other Documentation ................................... 7-1

7.1 Dimensions ....................................................................................................................... 7-2

7.1.1 GT01/GT01R ............................................................................................................... 7-2

7.1.2 GT02 ........................................................................................................................... 7-3

7.1.3 GT02L ......................................................................................................................... 7-4

7.1.4 GT05 ........................................................................................................................... 7-5

7.1.5 GT11 ........................................................................................................................... 7-6

7.1.6 GT12 ........................................................................................................................... 7-7

7.1.7 GT21 ........................................................................................................................... 7-8

7.1.8 GT32 ........................................................................................................................... 7-9

7.1.9 GT32-E ...................................................................................................................... 7-10

7.2 Cable Specifications ...................................................................................................... 7-11

7.2.1 AIGT8142 .................................................................................................................. 7-11

7.2.2 AIGT8152 .................................................................................................................. 7-11

7.2.3 AIGT8162/AIGT8165/AIGT8160 ............................................................................... 7-11

iv

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.2.4 AIGT8175 .................................................................................................................. 7-12

7.2.5 AIP81842 .................................................................................................................. 7-12

7.3 Table of Screen Messages ............................................................................................ 7-13

7.4 BIN/HEX/BCD Code Correspondence Table ............................................................... 7-14

7.5 ASCII Code Table ........................................................................................................... 7-15

Record of changes

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Before You Start

Usage conditions

Operating environment (Use the unit within the range of the general specifications when installing)

-

-

-

-

-

Ambient temperatures: 0 to +50 C

(It varies according to models when installing the unit in a horizontal orientation or using a C-NET adapter and FP programmer II.)

Ambient humidity: 20 to 85% RH (at 25 C, non-condensing)

Altitude of 2000 m or less

For use in pollution Degree 2 environment

Do not use it in the following environments.

- Direct sunlight, wind and rain. (This product is not designed for outdoor use.)

- Sudden temperature changes causing condensation.

- Inflammable or corrosive gas.

- Excessive airborne dust, metal particles or saline matter.

- Benzine, paint thinner, alcohol or other organic solvents or strong alkaline solutions such as ammonia or caustic soda.

- Direct vibration, shock or places always exposed to drop of water.

(This unit is warranted by IP65/IP67 (depending on models) for panel mounting, however, this applies to initial values.)

- Influence from power transmission lines, high voltage equipment, power cables, power equipment, radio transmitters, or any other equipment that would generate high switching surges. (100 mm or more)

The usage conditions for Tough series (GT32-E) are as follows.

-

Ambient temperatures: -20 to +60 C (When horizontally installed, -20 to +55 C)

-

Ambient humidity: 10 to 90% RH (at 25 C, non-condensing)

- The upper limit of the humidity at each temperature is as below.

(Below 40 C; 90%RH, 50 C; 55%RH, 60 C; 35%RH)

- If the product is exposed to heavy rain, condensation might be caused by sudden temperature changes.

-

-

-

Altitude of 2000 m or less

For use in pollution Degree 2 environment

Do not use it in the following environments.

- Direct sunlight for a long time

(Exposing the product to direct sunlight increases the surface temperature of the display higher than ambient temperature, and causes deterioration of LDC panel.)

- Inflammable or corrosive gas.

- Excessive airborne dust, metal particles or saline matter.

- Benzine, paint thinner, alcohol or other organic solvents or strong alkaline solutions such as ammonia

or caustic soda.

- Direct vibration, shock or places always exposed to drop of water.

(This unit is warranted by IP67 for panel mounting, however, this applies to initial values.)

- Influence from power transmission lines, high voltage equipment, power cables, power equipment, radio transmitters, or any other equipment that would generate high switching surges. (100 mm or more)

-

-

-

Static electricity

Do not touch connector pins directly to prevent static electricity from causing damage.

Always rid yourself of any static electricity before handling this product.

If excessive estatic electricity is applied to the panel surface, the LCD panel unit may be damaged.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

vii

-

-

-

-

Power supply

Twist the wires of the power supply.

The unit has sufficient noise immunity against the noise generated on the power line. However, it is recommended to take measures for reducing noise such as using an isolating transformer before supplying the power. And it is recommended to take measures such as installing a ferrite core.

Allocate an independent wiring for each power supplying line, PLC etc and operating device.

If using a power supply withoug a protective circuit, power should be supplied through a protective element such as fuse. Directly applying an abnormal voltage to the unit may cause the damage to the internal circuit.

Touch switches

-

Always operate the touch switch with fingers. As the touch switch may be damaged due to the excessive load or shock (caused when being operated with any tools), the touch switch should be operated within the specified control force. Also, if the touch swich is pressed like kneading, the electrode may be worn out exceptionally, and cause the malfunction. Operate with a single touch of the switch.

-

The touch position may shift due to aging variation. If the touch position has shifted, please adjust it.

LCD panel

-

Do not drop or have a strong impact on the programmable display unit as glass is used for the LCD

- panel.

The liquid in the LCD panel is a hazardous substance. If the LCD panel is broken, do not put the leaked crystalline liquid into your mouth. Should it get into your mouth, immediately gargle, and consult a doctor. If it adheres to your skin or clothes, wash it away with soap.

-

There is a case that shadows appear in the place on the screen of the GT where no graphic or part is arranged. (The shadows appear as the extension of the characters, graphics or parts actually being displayed.) This is a phenomenon resulting from the basic characteristics of liquid crystal devices, and called cross talk.

Battery

Do not leave the battery in the unit when it is not used. There is a possibility of leak if it is left being discharged. viii

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Manuals to be Used

-

The manuals to be used for GT series are common to all the models.

GT series User's Manual ARCT1F511E

-

It is this manual. This manual describes the characteristics, specifications, installation and connections of each GT models.

GT series Reference Manual ACGM0357V**EN

-

This manual describes the screen creation of GT series and the settings of various functions.

General-purpose Serial Communication Manual ARCT1F356E

-

It is required when communication is carried out with devices you developed such as a board and PC.

Connection with Other Companies' PLCs Manual ARCT1F449E

It is a manual describing the connection methods with PLCs manufactured by other companies. The connection methods with Panasonic PLCs are described in this manual.

Installation Guide ARCT1F513E

It is a manual describing how to install GTWIN. It supplied with the GTWIN software product.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

ix

Available Functions and GT Versions

We recommend to keep GT-series products up to date for use as usable functions will increase according to the upgrade.

The latest version of GT can be installed by the tool.

The upgrade of GTWIN is also necessary according to the upgrade of GT.

Version of GT01 and available functions

Function

Parts library

Switch

Lamp

Message

Data

Bar graph

Clock

Line graph

Alarm

History

List

Other

Keyboard

Custom functions Recipe

Recipe

SD recipe

Flow display

Write device

Sound

Password

Password

Operation security

Multi language exchange

Logging function

Display panel sideways setting

Copy

Cable between GTs

SD memory card

GT link

PLC multiple connection

Note1) Only referring to PLC can be set.

GT01

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

Note1)

1.00 or later

Not available

Not available

1.00 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

Not available

1.00 or later

Not available

1.20 or later

Not available

1.10 or later

1.30 or later

Not available

Not available

Not available

GTWIN

2.30 or later

2.30 or later

2.30 or later

2.30 or later

2.30 or later

2.30 or later

2.30 or later

Not available

Not available

2.30 or later

2.30 or later

2.30 or later

Not available

2.30 or later

2.30 or later

Not available

2.30 or later

Not available

2.50 or later

Not available

2.40 or later

-

Not available

Not available

Not available x

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Version of GT02 and available functions

Function GT02M2

GT02G2

GT02M0

GT02M1

GT02G0

GT02G1

Parts library

Switch

Lamp

Message

Data

Bar graph

Clock

Line graph

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later 1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later 1.00 or later

Note1)

Alarm

Keyboard

Custom

Other functions Recipe

Flow display

Write device

Sound

Password

History

List

Recipe

SD recipe

Password

Operation security

Multi language exchange

Logging function

FP monitor function

Display panel sideways setting

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.30 or later

1.00 or later

Copy

Cable between GTs Not available

SD memory card

GT link

PLC multiple connection

1.00 or later

1.00 or later

1.00 or later

Note1) Only referring to PLC can be set.

1.00 or later

Not available

1.00 or later

1.00 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

1.00 or later

Not available

1.30 or later

1.00 or later

Not available

Not available

1.00 or later

1.00 or later

GTWIN

2.A0 or later

2.A0 or later

2.A0 or later

2.A0 or later

2.A0 or later

2.A0 or later

2.A0 or later

2.A0 or later

2.A0 or later

1.00 or later

1.00 or later

2.A0 or later

2.A0 or later

2.A0 or later

2.A0 or later

Not available

2.A0 or later

2.A0 or later

2.A0 or later

2.A0 or later

2.C0 or later

2.A0 or later

Not available

2.A0 or later

2.A0 or later

2.A0 or later

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

xi

Version of GT02L and available functions

Function

Parts library

Switch

Lamp

Message

Data

Bar graph

Clock

Line graph

Alarm

History

List

Keyboard

Custom

Other functions Recipe

Recipe

SD recipe

Flow display

Write device

Sound

Password

Password

Operation security

Multi language exchange

Logging function

FP monitor function

Display panel sideways setting

Copy

Cable between GTs

SD memory card

GT link

PLC multiple connection

Note1) Only referring to PLC can be set.

GT02L

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

Note1)

1.00 or later

Not available

1.00 or later

1.00 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

1.00 or later

Not available

1.20 or later

1.00 or later

Not available

Not available

1.00 or later

1.00 or later

GTWIN

2.B0 or later

2.B0 or later

2.B0 or later

2.B0 or later

2.B0 or later

2.B0 or later

2.B0 or later

2.B0 or later

2.B0 or later

1.00 or later

1.00 or later

2.B0 or later

2.B0 or later

2.B0 or later

2.B0 or later

Not available

2.B0 or later

2.B0 or later

2.B0 or later

Not available

2.C0 or later

2.B0 or later

Not available

Not available

2.B0 or later

2.B0 or later

Note:

The buzzer function is not available for GT02L. All the functions related to the buzzer are unsupported. xii

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Version of GT05 and available functions

Function

Parts library

Switch

Lamp

Message

Data

Bar graph

Clock

Line graph

Alarm

History

List

Keyboard

Custom

Other functions Recipe

Recipe

SD recipe

Flow display

Write device

Sound

Password

Password

Operation security

Multi language exchange

Logging function

FP monitor function

Display panel sideways setting

Copy

Cable between GTs

SD memory card

GT link

PLC Multiple Connection

GT05

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.60 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.10 or later

1.00 or later

1.40 or later

1.90 or later

2.00 or later

Not available

1.00 or later

1.10 or later

1.30 or later

GTWIN

2.90 or later

2.90 or later

2.90 or later

2.90 or later

2.90 or later

2.90 or later

2.90 or later

2.90 or later

2.90 or later

2.90 or later

2.90 or later

2.90 or later

2.A0 or later

2.90 or later

2.90 or later

Not available

2.90 or later

2.94 or later

2.90 or later

2.98 or later

2.C0 or later

2.C1 or later

Not available

2.90 or later

2.94 or later

2.97 or later xiii

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Version of GT11 and available functions

Function

Parts library

Switch

Lamp

Message

Data

Bar graph

Clock

Line graph

Alarm

History

List

Keyboard

Custom

Other functions Recipe

Recipe

SD recipe

Flow display

Write device

Sound

Password

Password

Operation security

Multi language exchange

Logging function

Display panel sideways setting

Copy

Cable between GTs

SD memory card

GT link

PLC multiple connection

Note1) Summer time cannot be set.

GT11

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

Note1)

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

Not available

1.00 or later

Not available

1.00 or later

Not available

1.00 or later

1.20 or later

Not available

Not available

Not available

GTWIN

2.60 or later

2.60 or later

2.60 or later

2.60 or later

2.60 or later

2.60 or later

2.60 or later

2.60 or later

2.60 or later

2.60 or later

2.60 or later

2.60 or later

Not available

2.60 or later

2.60 or later

Not available

2.60 or later

Not available

2.60 or later

Not available

2.60 or later

-

Not available

Not available

Not available xiv

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Version of GT12 and available functions

Function

Parts library

Switch

Lamp

Message

Data

Bar graph

Clock

Line graph

Alarm

History

List

Other

Keyboard

Custom functions Recipe

Flow display

Write device

Sound

Password

Recipe

SD recipe

Password

Operation security

Multi language exchange

Logging function

FP monitor function

Display panel sideways setting

Copy

Cable between GTs

SD memory card

GT link

PLC multiple connection

GT12M1 GT12M0 GTWIN

GT12G1 GT12G0

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

2.97 or later

2.97 or later

2.97 or later

2.97 or later

2.97 or later

2.97 or later

2.97 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

2.97 or later

2.97 or later

2.97 or later

2.97 or later

1.00 or later

1.20 or later

1.00 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

2.97 or later

2.A0 or later

2.97 or later

2.97 or later

Not available Not available Not available

1.00 or later 1.00 or later 2.97 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.10 or later

1.60 or later

1.00 or later

Not available

1.60 or later

1.00 or later

Not available Not available

1.00 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

2.97 or later

2.97 or later

2.98 or later

2.C0 or later

2.97 or later

Not available

2.97 or later

2.97 or later

2.97 or later

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

xv

Version of GT21 and available functions

Function

Parts library

Switch

Lamp

Message

Data

Bar graph

Clock

Line graph

Alarm

History

List

Keyboard

Custom

Other functions Recipe

Recipe

SD recipe

Flow display

Write device

Sound

Password

Password

Operation security

Multi language exchange

Logging function

Display panel sideways setting

Copy

Cable between GTs

SD memory card

GT link

PLC multiple connection

Note1) Summer time cannot be set.

GT21

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

Note1)

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

Not available

1.00 or later

Not available

1.00 or later

Not available

1.10 or later

1.10 or later

Not available

Not available

Not available

GTWIN

2.70 or later

2.70 or later

2.70 or later

2.70 or later

2.70 or later

2.70 or later

2.70 or later

2.70 or later

2.70 or later

2.70 or later

2.70 or later

2.70 or later

Not available

2.70 or later

2.70 or later

Not available

2.70 or later

Not available

2.70 or later

Not available

2.71 or later

-

Not available

Not available

Not available xvi

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Version of GT32 and available functions

Function

Parts library

Switch

Lamp

Message

Data

Bar graph

Clock

Line graph

Alarm

History

List

Keyboard

Custom

Other functions Recipe

Recipe

SD recipe

Flow display

Write device

Sound

Password

Password

Operation security

Multi language exchange

Logging function

FP monitor function

Display panel sideways setting

Copy

Cable between GTs

SD memory card

GT link

PLC multiple connection

GT32M

GT32T0

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.60 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.20 or later

1.00 or later

1.50 or later

2.00 or later

2.10 or later

Not available

1.00 or later

1.20 or later

1.40 or later

GT32T1 GTWIN

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.60 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.20 or later

1.00 or later

2.94 or later

2.80 or later

1.50 or later

2.00 or later

2.10 or later

2.98 or later

2.C0 or later

2.C1 or later

Not available Not available

1.00 or later

1.20 or later

1.40 or later

2.80 or later

2.94 or later

2.97 or later

2.80 or later

2.80 or later

2.80 or later

2.80 or later

2.80 or later

2.80 or later

2.80 or later

2.80 or later

2.80 or later

2.80 or later

2.80 or later

2.80 or later

2.A0 or later

2.80 or later

2.80 or later

2.80 or later

2.80 or later xvii

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Version of GT32-E and available functions

Function

Parts library

Switch

Lamp

Message

Data

Bar graph

Clock

Line graph

Alarm

History

List

Keyboard

Custom

Other functions Recipe

Recipe

SD recipe

Flow display

Write device

Sound

Password

Password

1.00 or later

Multi language exchange

Logging function

FP monitor function

Display panel sideways setting

Copy

Cable between GTs

1.00 or later

GT link

PLC multiple connection

GT32M-E

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.10 or later

Not available

1.00 or later

1.00 or later

1.00 or later

GT32T1-E

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.00 or later

1.60 or later

1.00 or later

1.00 or later

Not available

1.00 or later

1.20 or later

1.00 or later

1.00 or later

1.00 or later

1.10 or later

Not available

1.00 or later

1.00 or later

1.00 or later

GTWIN

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

Not available

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C0 or later

2.C1 or later

Not available

2.C0 or later

2.C0 or later

2.C0 or later xviii

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Change history

GTWIN GT-series version version

Ver. 2.80 GT32 Ver. 1.00

(New release)

Ver. 2.90

Ver. 2.94

Ver. 2.96

Ver. 2.97

GT05 Ver. 1.00

(New release)

GT05 Ver. 1.10

GT32 Ver. 1.20

GT01 Ver. 1.35

GT05 Ver. 1.20

GT11 Ver. 1.25

GT21 Ver. 1.15

GT32 Ver. 1.30

GT05 Ver. 1.30

GT12 Ver. 1.00

(New release)

GT32 Ver. 1.40

GT01 Ver.1.35

GT11 Ver.1.25

GT21 Ver.1.15

GT05 Ver. 1.40

GT12 Ver. 1.10

GT32 Ver. 1.50

Additional functions

-

-

-

-

New model

Equipped a SD memory card slot.

Sound function

New model

-

-

-

Operation security function

GT link function

Touch sound disable flag in Basic communication area

(Bit area)

-

-

-

-

-

-

-

New model

"Mult Function" function

PLC multiple connection

Display/Hide of data parts

Modbus slave function

Added 4096-color parts library.

Modbus slave function

Ver. 2.98

-

GT02 Ver.1.00

(New release)

GT05 Ver.1.60

GT12 Ver.1.30

GT32 Ver.1.70

-

-

-

-

-

-

-

-

-

-

-

-

Logging function

Index modifier of data parts

Display/Hide of switch parts

Display of data parts in kana and Chinese character, kana input of keyboard parts・Unit number setting on GT when using General-purpose serial

SD memory card copy to password-protected GT

Connection between multiple units with Modbus(RTU) master

Output to Panasonic FP series "X" device.

Jump to the prvious screen from "Screen No. Error" screen

Reverse display function

Jump to the prvious screen from "Screen No. Error" screen

Reverse display function

Bug fixing

GT01 Ver. 1.37

GT11 Ver. 1.27

Ver.2.983 GT05 Ver.1.42

GT12 Ver.1.12

Ver.2.99

GT32 Ver.1.52

GT05 Ver.1.50

GT12 Ver.1.20

GT32 Ver.1.60

-

Functions for devices such as Temperature control device of

-

-

-

-

-

-

-

MODBUS (RTU mode)

Display of data parts in Chinese and Korean

Graph display of logging device data for logging function

Bar graph of line graph parts

Fixed line of line graph parts

Supports SDHC memory card

Display/Hide of keyboard parts in GTWIN

New model Ver.2.A0

-

-

SD recipe function

Function for communication errors in case of PLC multiple

-

-

- connection

Alarm history data save in SD memory card

Multiplication and division of write device data

Multiplication and division of write device data

Ver.2.B0

GT05 Ver.1.40

GT12 Ver.1.30

GT32 Ver.1.20

GT02L Ver.1.00

(New release)

GT02 Ver.1.10

GT05 Ver.1.70

GT12 Ver.1.40

GT32 Ver.1.80

-

-

New model (GT02L)

True Type font for data parts xix

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Ver.2.B1

Ver.2.C0

Ver.2.C1

GT01 Ver.1.39

GT02 Ver.1.11

GT02L Ver.1.01

GT05 Ver.1.71

GT11 Ver.1.29

GT12 Ver.1.41

GT21 Ver.1.19

GT32 Ver.1.81

GT02 Ver.1.30

GT02L Ver.1.20

GT05 Ver.1.90

GT12 Ver.1.60

GT32 Ver.2.00

GT32-E Ver.1.00

GT02 Ver.1.40

GT02L Ver.1.30

GT05 Ver.2.00

GT12 Ver.1.70

GT32 Ver.2.10

GT32-E Ver.1.10

-Bug fixing

-

New model(GT32-E)

-

FP monitor function

-

Added the mode to ignore CS/RS when using general-

- purpose serial communication.

Fixed font conversion function

-

Vertical type display (GT05/GT32/GT32-E)

-

Device change function

-

Added the SD memory card installation flag in Basic

-

Communication Area.

Added parts library. xx

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Chapter 1

Features and Functions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

1.1 Features and Functions of GT Series

Can be installed in a small space.

As the GT series is a small and thin-shaped body, it can be installed in a small space. Also, as the projecting part from a wall surface is 4 mm, it looks neat after installation.

The GT01, GT02, GT02L, GT11, GT12 and GT21 can be installed in vertical orientation.

Number of colors can be selected as usage.

GT series

GT21C

GT05S/GT32T0/GT32T1/GT32T-E

Number of colors

256 colors

4096 colors

Monochrome 8-gradation (GT12)/16-gradation (GT32M-E) display function is available.

The monochrome 8-gradation and 16-gradation displays can be selected as well as the existing monochrome 2-gradation display, so that the screen can be displayed finely.

Easily shows a current state changing the backlight on the monochrome type.

For the monochrome type (3-color LED backlight type), changing in the backlight color makes it easy to grasp a current state at a glance.

"Green, orange, red" type and "White, red, pink" type is available for the 3-color LED backlight type.

Analog touch panel provided

As an analog touch panel is provided, it allows maximum flexibility in the switch layout and size.

Screens can be created easily, using a special screen creation tool Terminal GTWIN.

Screen contents can be easily created using the dedicated Terminal GTWIN tool. Screens are put together simply by selecting parts from libraries and positioning them in place.

Various parts for numerous applications are provided such as 256-color 3D parts.

Screen data of the other models can be used with the model conversion function.

Screen data can be converted from the low-resolution model to high-resolution model, e.g. from GT01 to

GT11, from GT21 to GT32.

The communication methods support RS232C/RS422 (RS485)

The communication methods to PLCs support RS232C/RS422(RS485). Also it can be connected to

PLCs manufactured by other companies.

Structure adapted to surrounding environments

IP65. It has a dust-proof, waterproof and drop-proof structure. (IP67 for GT02, GT12 and GT32-E)

High-intensity LED provided (LED backlight type)

As the high-intensity LED is provided, the screen is bright, and the backlight does not need to be replaced.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Saving various data with a SD memory card (Model equipped with SD memory card slot

Various data can be saved and read out with a SD memory card.

Power can be supplied to the 5 V DC type with only one communication cable.

The power is supplied from the TOOL port of a PLC, therefore, the wiring man-hours can be significantly reduced.

Applicable models:

Panasonic FP series

Mitsubishi Electric Corporation FX series

Three methods are available to switch the screen.

Switching by the instruction from PLC

The screens can be switched by writing to the “basic communication area” from the PLC ladder program.

Switching with the touch-screen operation

The screens can be switched on the GT by using the “function switching parts” provided in the parts library of the GTWIN that has a function to switch the screens.

Switching automatically

The GT man unit has an “Auto-paging” function in the configuration setting that automatically switches the screen to a specified screen number when a certain period of time has elapsed. This function can be used to switch screens automatically.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Through function is convenient for debugging

A convenient “through” function makes it possible to transfer data from the GT and carry out PLC debugging at the same time that communication is going on between the GT and the FP series PLC.

This significantly boosts efficiency in the workplace.

For TOOL port models

For USB port/Ethernet port models

New functions can be available by upgrading the GT.

The GT can be easily upgraded by donwloading the latest firmware from our website or using the GT

Ver_UP tool.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Security Function

- Password protection function

A password (max. 8 characters) is specified for trasferring the screen data to GT from GTWIN. This function prevents the outflow of screen data if anyone except the administrator tries to read out the screen data.

- Operation security function (GT02, GT02L, GT05, GT12, GT32, GT32-E)

This function is used to limit the contents of displays and operations by setting the security level of users for each part.

The level of operators are managed with the security password.

GT link function (GT02, GT02L, GT05, GT12, GT32, GT32-E)

This function is used to connect multiple GT units (up to 32 units) to a single PLC (Panasonic FP series).

RS485 communication is used.

Note) Station numbers should be set to the connected GT units. The both settings for GT and PLC are necessary.

PLC Multiple Connection (GT02, GT02L, GT05, GT12, GT32, GT32-E)

This is a function that enables multiple Panasonic PLCs (FP series) (up to 31 units) to be connected with one GT. Communication is performed via RS485.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Logging function (Model equipped with SD memory card slot)

It is a function to collect and log arbitrary device values into a PLC at a constant period or when conditions are met.

Logged data is saved in a SD memory card inserted in this unit in CSV format.

This function is useful for obtaining the history of data.

FP monitor function (GT02, GT02L, GT05, GT12, GT32, GT32-E)

This function is used to monitor or change the settings and data of FP-series PLC on the GT screen.

Without creating screens in advance or connecting to a PC, the operational check of equipment in the actual environment, the start-up of equipment and daily maintenance work can be performed efficiently.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

1.2 Types of Units

1.2.1 GT Series

Item name

GT01

GT02

Model

GT01

GT01R

GT02M0

GT02M1

GT02G2

Display

STN monochrom e LCD

(128x64 dots)

Interface specifications

COM port

TOOL port

(RS232C compliant)

COM port

USB port (USB1.1 compliant)

GT02M2

GT02G0

STN monochrom e LCD

(240x96 dots)

COM port

USB port (USB1.1 compliant) with SD memory card slot

GT02G1

COM port

USB port (USB1.1 compliant)

COM port

USB port (USB1.1 compliant) with SD memory card slot

Backlight

3-color

LED

(green, red, orange)

1-color

LED

(white)

3-color

LED

(white, red, pink)

3-color

LED

(white, red, pink)

3-color

LED

(green, red, orange)

Power supply

5 V DC

24 V

DC

5 V DC

24 V

DC

5 V DC

24 V

DC

5 V DC

24 V

DC

5 V DC

24 V

DC

COM port communication specification

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

Front panel color

Model No.

Black

Ashgray

Black

Ashgray

Black

Ashgray

Black

Ashgray

Black

Ashgray

Black

Ashgray

Black

Ashgray

Black

Ashgray

AIGT0030B1

AIGT0030H1

AIGT0032B1

AIGT0032H1

AIGT0030B

AIGT0030H

AIGT0032B

AIGT0032H

AIGT0130B1

AIGT0130H1

AIGT0132B1

AIGT0132H1

AIGT0130B

AIGT0130H

AIGT0132B

AIGT0132H

Pure black AIGT0230B1

Silver AIGT0230H1

Pure black AIGT0232B1

Silver AIGT0232H1

Pure black AIGT0230B

Silver AIGT0230H

Pure black AIGT0232B

Silver AIGT0232H

Pure black AIG02MQ02D

Silver AIG02MQ03D

Pure black AIG02MQ04D

Silver AIG02MQ05D

Pure black AIG02MQ12D

Silver AIG02MQ13D

Pure black AIG02MQ14D

Silver AIG02MQ15D

Pure black AIG02MQ22D

Silver AIG02MQ23D

Pure black AIG02MQ24D

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

Silver AIG02MQ25D

Pure black AIG02GQ02D

Silver AIG02GQ03D

Pure black AIG02GQ04D

Silver AIG02GQ05D

Pure black AIG02GQ12D

Silver AIG02GQ13D

Pure black AIG02GQ14D

Silver AIG02GQ15D

Pure black AIG02GQ22D

Silver AIG02GQ23D

Pure black AIG02GQ24D

RS422

(RS485)

Silver AIG02GQ25D

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Item name

GT02L

GT05

GT11

GT12

GT21

Model

GT02L

GT05M

GT05G

GT05S

GT11

GT12M0

GT12M1

GT12G0

GT12G1

GT21

Display

STN monochro me LCD

(160x64 dots)

STN monochro me LCD

(320x240 dots)

4096color STN color LCD

(320x240 dots)

STN monochro me LCD

(240x96 dots)

Interface specifi-cations

COM port

USB port

(USB1.1 compliant)

COM port

USB port

(USB1.1 compliant) with SD memory card slot

COM port

TOOL port

(RS232C compliant)

STN monochro me LCD

(320x120 dots)

COM port

TOOL port

(RS232C compliant)

COM port

USB port

(USB1.1 compliant) with SD memory card slot

COM port

TOOL port

(RS232C compliant)

COM port

USB port

(USB1.1 compliant) with SD memory card slot

256-color

STN color

LCD

(320x240 dots)

COM port

TOOL port

(RS232C compliant)

Backlight

1-color

LED

(white)

3-color

LED

(white, red, pink)

3-color

LED

(green, red, orange)

1-color

LED

(white)

3-color

LED

(green,red

, orange)

1-color

LED

(white)

3-color

LED

(white, red, pink)

Power supply

5 V DC

COM port communication specification

RS232C

RS422

(RS485)

Front panel color

Black

24 V

DC

24 V

DC

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

Pure black

Silver

Pure black

Silver

Pure black

Silver

Pure black

Silver

Pure black

Silver

Black

Ashgray

Black

Ashgray

Black

Ashgray

Black

Ashgray

Black

Ashgray

Pure black

Silver

Pure black

Silver

Pure black

Silver

Pure black

Silver

24 V

DC

3-color

LED

(green, red, orange)

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

Pure black

Silver

Pure black

Silver

Pure black

Silver

Pure black

1-color

LED

(white)

5 V

DC

RS232C

RS422

(RS485)

Silver

Pure black

Silver

Pure black

Silver

Model No.

AIG02LQ02D

AIG02LQ04D

AIG05MQ02D

AIG05MQ03D

AIG05MQ04D

AIG05MQ05D

AIG05GQ02D

AIG05GQ03D

AIG05GQ04D

AIG05GQ05D

AIG05SQ02D

AIG05SQ03D

AIG05SQ04D

AIG05SQ05D

AIGT2030B

AIGT2030H

AIGT2032B

AIGT2032H

AIGT2130B

AIGT2130H

AIGT2132B

AIGT2132H

AIG12MQ02D

AIG12MQ03D

AIG12MQ04D

AIG12MQ05D

AIG12MQ12D

AIG12MQ13D

AIG12MQ14D

AIG12MQ15D

AIG12GQ02D

AIG12GQ03D

AIG12GQ04D

AIG12GQ05D

AIG12GQ12D

AIG12GQ13D

AIG12GQ14D

AIG12GQ15D

AIGT2230B

AIGT2230H

AIGT2232B

AIGT2232H

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Item name

Model Display

GT32M

STN monochrome

LCD

(320x240 dots)

COM port

USB port

(USB1.1 compliant) with SD memory card slot

GT32T0

GT32

GT32T1

4096color

TFT color

LCD

(320x240 dots)

COM port

USB port

(USB1.1 compliant)

Ethernet port with SD memory card slot with sound output jack

GT32-E

GT32M-E

GT32T-E

TFT monochro me LCD

(320x240 dots)

4096color

TFT color

LCD

(320x240 dots)

COM port

USB port

(USB1.1 compliant) with SD memory card slot

1.2.2 Options and Repair Parts

Interface specifi-cations

Backlight

CFL

Power supply

24 V

DC

COM port communication specification

RS232C

Body color

Pure black

Silver

Pure black

RS422

(RS485)

RS232C

RS422

(RS485)

RS232C

Silver

Pure black

Silver

Pure black

Silver

Pure black

Silver

Pure black

RS422

(RS485)

Silver

Model No.

AIG32MQ02D

AIG32MQ03D

AIG32MQ04D

AIG32MQ05D

AIG32TQ02D

AIG32TQ03D

AIG32TQ04D

AIG32TQ05D

AIG32TQ12D

AIG32TQ13D

AIG32TQ14D

AIG32TQ15D

1-color

LED

(white)

24 V

DC

RS232C

RS422

(RS485)

RS232C

RS422

(RS485)

Silver

AIG32MQ03DE

AIG32MQ05DE

AIG32TQ03DE

AIG32TQ05DE

PLC connecting cables

Item name Contents

For connection between GT01/GT02/GT02L (5V

DC type (RS232C)) and our FP-series TOOL port

Mini-DIN 5-pin loose-wire cable

* A ferrite core is supplied with the main unit.

For connection between GT01/GT02/GT02L (5V

DC type (RS422)) and MITSUBISHI FX-series

TOOL port

Mini-DIN 8-pin loose-wire cable

* A ferrite core is supplied with the main unit.

For connection between 24V DC type (RS232C) and our FP-series TOOL port

Mini-DIN 5-pin loose-wire cable

For connection between 24V DC type (RS422) and MITSUBISHI FX-series TOOL port

Mini-DIN 8-pin loose-wire cable

For connection to COM port of FP2/FP2SH and

FP2 computer communication unit

D-SUB 9-pin loose-wire cable

Product No.

2 m AIGT8142

2 m AIGT8152

2 m AIGT8162

5 m AIGT8165

10 m AIGT8160

5 m AIGT8175

2 m AIP81842

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Maintenance parts

Item name

Waterproof packing

Contents

For GT01

For GT02/GT02L

For GT05

For GT11

For GT12

For GT21

For GT32

For GT32-E

Note)

For repair

GT01/GT11 repair

(4 pc/set)

For GT05/GT21 repair (2 pc/set)

10 in set

Product

No.

AIGT081

AIG02810

AIG05810

AIGT181

AIG2810

AIGT28121

AIG32810

AIG32810E

5 sets AIGT083

Attachment fittings

5 sets AIGT28321

For GT32/GT32-E repair (2 pc/set) 5 sets AIG32830

Attachment fittings

(with dedicated screws)

For GT02/GT02L/GT12 repair

(4 pc each/set)

Connector

COM port connector for repair

(8-pin)

5 in set AIGT084

Note) Although it is for GT02, it can be also used for GT02L. It is different from the packing attached to the GT02 unit.

Options

Item name

Front panel protective sheet

For GT02/GT02L

For GT05

For GT11

For GT12

For GT21

For GT32

Contents

Sold separately 10 in set

Sold separately

Product

No.

AIGT080

AIGT080R

AIG02800

AIG05800

AIGT280

AIG12800

AIGT28021

AIGT32800

Backup battery

Backup battery for

GT02M2,GT02G2/GT05/GT12/GT32/

GT32-E

5 sets

1 pc

AIG12830

AFPX-BATT

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Commercial product

Item name Contents Model No.

Backup battery

Backup battery for GT11/GT21 1 pc CR2032

Item name

Printe d logo on GT

GT02M2

GT02G2

GT version (Ver.)

GT05 GT12 GT32 GT32-E

Usable SD memory card

Card type Capacity

SD memor

1.00 or later

1.00 or later

1.39 or older

1.40 or later

1.09 or older

1.10 or later

1.49 or older

1.50 or later

1.00 or later

1.00 or later

SD memory card

SD memory card

SDHC memory card

CLASS2, 4

32M to

1GB

32M to

2GB

4GB to

16GB

y card

1.00 or later

1.00 or later

1.39 or older

1.40 or later

1.09 or older

1.10 or later

1.49 or older

1.50 or later

1.00 or later

1.00 or later

SD memory card

SD memory card

SDHC memory card

32M to

1GB

32M to

2GB

4GB to

32GB

Note) Select the capacity of a SD memory card according to the logo printed on the GT and the version of GT firmware.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

1.3 Screen Creation Tool

1.3.1 Tools Required for Screen Creation

1. Tool software

It can be used for all the models in the GT series.

2. Screen transfer cable (Cable for connecting a PC)

For GT01, GT11 and GT21:

A cable between a PC (D-sub 9-pin) and GT (TOOL port) is available.

For GT02, GT02L, GT05, GT12, GT32 and GT32-E:

Prepare a commercal USB cable or LAN cable (for GT32T1 only).

1.3.2 Software Usage Environment and Applicable Cables

Screen creation tool software Terminal GTWIN Ver. 2

Software type Required OS Hard disk capacity Product No.

Terminal GTWIN Ver. 2

Terminal GTWIN Ver. 2

Upgrade model

Englishlanguage version

Englishlanguage version

Windows 7

Windows Vista

Windows 2000

Windows XP

400 MB or more

Note1) The latest version is provided free of charge via our website

(User registration is required. Free of charge)

AIGT8001V2

AIGT8001V2R

Related software (Freeware)

Item name Contents

Configurator WD IP address search tool Address setting for the GT in Ethernet communication

Note) It can be downloaded from our website.

(User registration is required. Free of charge)

1-12

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Screen transfer cable

For connection between PC (USB) and Programmable Display (GT02/GT02L/GT05/GT12/GT32)

USB cable (Commercial product) Applicable model Cable type Length

GT05/GT32/

GT32-E

USB2.0 (or 1.1) AB type Max. 5 m

GT02/GT02L/GT12

USB2.0 (or 1.1) cable

A type (Male): miniB type male

Note) Windows 2000 or later OS is required for the communication with a USB.

Max. 5 m

For connection between PC (RS232C) and Programmable Display (GT01/GT11/GT21)

D-sub connector cable

PC side

connector

GT side

connector

Specification Product No.

D-sub 9-pin

Mini DIN round 5-pin

L type (3 m) AFC8503

Straight type

(3 m)

AFC8503S

Note) A USB/RS232C conversion cable is necessary to connect with a personal computer without a serial port using a PC connection cable.

LAN cable (Ethernet port) (GT32T1)

Either straight cable or crossing cable can be used.

(MDI/MDI-X Automatic crossover function)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Chapter 2

Names and Functions of Parts

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.1 Part Names

2.1.1 GT01, GT11 and GT21

GT01/GT01R

GT11

GT21

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Touch screen

Various screens are displayed here. Switches can be operated and data entered simply by touching the touch screen.

(A sheet is affixed to the touch panel to protect it from scratches when shipping. Please remove it before using the GT.)

Optional protective sheets are available to protect the touch screen surface and keep it clean.

Reference:

<1.4.2 Options and Repair Parts>

COM port and power supply terminal

This is a communication port (RS232C or RS422) for connecting to a PLC, host PC, or microcomputer board, and a power supply terminal for operation.

TOOL port (GTWIN connection port)

This port is used to connect the screen creation tool.

Operation mode setting switches

Setting the operation mode setting switches as follows when turning on the power supply enables the setting to inhibit to move to the system menu or enables to clear F-ROM.

Setting

Normal use

(Factory default)

Inhibit system menu shift Clear F-ROM

Switch setting

Note: Do not use any settings other than the above settings.

Waterproof packing

This assures that the front panel is waterproof.

Battery cover (for GT11 and GT21)

When using a backup battery to be separately purchased, open this battery cover to install it.

The clock, PLC device hold data, alarm history and GT internal device hold data functions can be used with the backup battery.

Reference:

<3.6.2 How to Install the Battery (Lithium Button Battery)>

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.1.2 GT02/GT02L

GT02M2, GT02G2

GT02M0, GT02M1, GT02G0, GT02G1

GT02L

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Liquid crystal display panel/touch panel

Various screens are displayed here. A touch panel is provided on the liquid crystal display panel, and switches can be operated and data entered simply by touching the panel.

Optional protective sheets are also available to protect the touch panel and keep it clean.

(A sheet is affixed to the touch panel to protect it from scratches when shipping. Please remove it before using the GT.)

SD memory card slot

A SD memory card is inserted in this slot.

-

Saving from GTWIN: Operate on the GTWIN screen using a SD memory card read/writer.

-

Savving from GT main unit: Operate on the SD memory card setting screen under the system menu.

USB port

This is a connector for connecting the screen creation tool. The commercal USB cable can be used.

SD memory access lamp

The lamp turns on while accessing a SD memory card.

Battery cover

When using a backup battery to be separately purchased, open this battery cover to install it.

The clock, PLC device hold data, alarm history and GT internal device hold data functions can be used with the backup battery.

Operation mode setting switches

Setting the operation mode setting switches as follows when turning on the power supply enables the setting to inhibit to move to the system menu or enables to clear F-ROM.

Setting

Normal use

(Factory default)

Inhibit system menu shift

Clear F-ROM

Switch setting

Mounting location of connector for battery

COM port (PLC/external device connection port) and power supply terminal

This is a communication port (RS232C or RS422) for connecting to a PLC, host PC, or microcomputer board, and a power supply terminal for operation.

Waterproof packing

This assures that the front panel is waterproof.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.1.3 GT05/GT12/GT32

GT05

GT12

GT32

Standard High function

GT32-E

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Liquid crystal display panel/touch panel

Various screens are displayed here. A touch panel is provided on the liquid crystal display panel, and switches can be operated and data entered simply by touching the panel.

Optional protective sheets are also available to protect the touch panel and keep it clean.

(A sheet is affixed to the touch panel to protect it from scratches when shipping. Please remove it before using the GT.)

-

-

SD memory card slot (Except GT12M0 and GT12G0)

A SD memory card is inserted in this slot.

Saving from GTWIN: Operate on the GTWIN screen using a SD memory card read/writer.

Savving from GT main unit: Operate on the SD memory card setting screen under the system menu.

USB port

This is a connector for connecting the screen creation tool. The commercal USB cable can be used.

Ethernet port (RJ45) (GT32T1)

This is a connector for connecting the screen creation tool. The maximum baud rate is 115200 bps when using Ethernet.

SPEED lamp (GT32T1)

It shows the baud rate when using Ethernet.

Light on: During 100Base communication

Blinking: During 10Base communication

LINK/ACT lamp (GT32T1)

it shows the state of communciation with Ethernet.

Light on: When linked

Blinking: While data reception

Sound output jack (GT32T1)

Insert the speaker with a  3.5-mini plug amplifier for using the audio output function.

SD memory access lamp (Except GT12M0 and GT12G0)

The lamp turns on while accessing a SD memory card.

Battery cover

When using a backup battery to be separately purchased, open this battery cover to install it.

The clock, PLC device hold data, alarm history and GT internal device hold data functions can be used with the backup battery.

Operation mode setting switches

Setting the operation mode setting switches as follows when turning on the power supply enables the setting to inhibit to move to the system menu or enables to clear F-ROM.

Normal use Inhibit system

Setting

(Factory default) menu shift

Clear F-ROM

Switch setting

Mounting location of connector for battery

COM port (PLC/external device connection port) and power supply terminal

This is a communication port (RS232C or RS422) for connecting to a PLC, host PC, or microcomputer board, and a power supply terminal for operation.

Waterproof packing

This assures that the front panel is waterproof.

2-7

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.2 Terminal Layouts of COM Port

2.2.1 GT01

5 V/RS232C type

Pin name

+

NC

SD

RD

NC

NC

SG

Name

+5 V

0 V

Not connected

Send data

Receive data

Not connected

Not connected

Signal ground

Note:

There is no RS and CS (control lines).

5 V/RS422(RS485) type

Pin name

+

NC

+SD

− SD

+RD

− RD

E

Name

+5 V

0 V

Not connected

Send data

Send data

Receive data

Receive data

Terminal resistance

Signal direction

-

-

-

GT→External device

GT←External device

-

-

-

Product No.

AIGT0030B1

AIGT0030H1

AIGT0130B1

AIGT0130H1

AIGT0230B1

AIGT0230H1

Signal direction

-

-

-

GT→External device(+)

GT→External device(−)

GT←External device(+)

GT←External device(−)

-

Product No.

AIGT0032B1

AIGT0032H1

AIGT0132B1

AIGT0132H1

AIGT0232B1

AIGT0232H1

Note:

There is no RS and CS (control lines).

24 V/RS232C type

Pin name

+

FG

SD

RD

NC

NC

SG

Name

+24 V

0 V

Functional ground

Send data

Receive data

Not connected

Not connected

Signal ground

Note:

There is no RS and CS (control lines).

24 V/RS422(RS485) type

Pin name

+

FG

+SD

− SD

+RD

− RD

E

+24 V

0 V

Name

Functional ground

Send data

Send data

Receive data

Receive data

Terminal resistance

Note:

There is no RS and CS (control lines).

Signal direction

-

-

-

GT→External device

GT←External device

-

-

-

Product No.

AIGT0030B

AIGT0030H

AIGT0130B

AIGT0130H

AIGT0230B

AIGT0230H

Signal direction

-

-

-

GT→External device(+)

GT→External device(−)

GT←External device(+)

GT←External device(−)

-

Product No.

AIGT0032B

AIGT0032H

AIGT0132B

AIGT0132H

AIGT0232B

AIGT0232H

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.2.2 GT02

5 V/RS232C type

5 V/RS422(RS485) type

Pin name

+

FG

SD

RD

RS

CS

SG

Pin name

+

FG

+SD

− SD

+RD

− RD

E

Name

+5 V

0 V

Functional ground

Send data

Receive data

Request to send

Clear to send

Signal ground

Signal direction

-

-

-

GT→External device

GT←External device

GT→External device

GT←External device

-

Product No.

AIG02MQ02D

AIG02MQ03D

AIG02GQ02D

AIG02GQ03D

Name

+5 V

0 V

Functional ground

Send data

Send data

Receive data

Receive data

Terminal resistance

Signal direction

-

-

-

GT→External device(+)

GT→External device(−)

GT←External device(+)

GT←External device(−)

-

Product No.

AIG02MQ04D

AIG02MQ05D

AIG02GQ04D

AIG02GQ05D

Note:

There is no RS and CS (control lines).

24 V/RS232C type

Name

+24 V

0 V

Functional ground

Send data

Receive data

Request to send

Clear to send

Signal ground

24 V/RS422(RS485) type

Pin name

+

FG

SD

RD

RS

CS

SG

Pin name

+

FG

+SD

− SD

+RD

− RD

E

Name

+24 V

0 V

Functional ground

Send data

Send data

Receive data

Receive data

Terminal resistance

Signal direction

-

-

-

GT→External device

GT←External device

GT→External device

GT←External device

-

Product No.

AIG02MQ12D

AIG02MQ13D

AIG02MQ22D

AIG02MQ23D

AIG02GQ12D

AIG02GQ13D

AIG02GQ22D

AIG02GQ23D

Signal direction

-

-

-

GT→External device(+)

GT→External device(−)

GT←External device(+)

GT←External device(−)

-

Product No.

AIG02MQ14D

AIG02MQ15D

AIG02MQ24D

AIG02MQ25D

AIG02GQ14D

AIG02GQ15D

AIG02GQ24D

AIG02GQ25D

Note:

There is no RS and CS (control lines).

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.2.3 GT02L

5 V/RS232C type

5 V/RS422(RS485) type

Pin name

+

FG

SD

RD

RS

CS

SG

Pin name

+

FG

+SD

− SD

+RD

− RD

E

Name

+5 V

0 V

Functional ground

Send data

Receive data

Request to send

Clear to send

Signal ground

Name

+5 V

0 V

Functional ground

Send data

Send data

Receive data

Receive data

Terminal resistance

Signal direction

-

-

-

GT→External device

GT←External device

GT→External device

GT←External device

-

Signal direction

-

-

-

GT→External device(+)

GT→External device(−)

GT←External device(+)

GT←External device(−)

-

Note:

There is no RS and CS (control lines).

Product No.

AIG02LQ02D

Product No.

AIG02LQ04D

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.2.4 GT11/GT12

24 V/RS232C type

Pin name

+

FG

SD

RD

RS

CS

Name

+24 V

0 V

Functional ground

Send data

Receive data

Request to send

Clear to send

SG Signal ground

Signal direction

-

-

-

GT→External device

GT←External device

GT→External device

GT←External device

-

Product No.

AIGT2030B

AIGT2030H

AIGT2130B

AIGT2130H

AIG12MQ02D

AIG12MQ03D

AIG12MQ12D

AIG12MQ13D

AIG12GQ02D

AIG12GQ03D

AIG12GQ12D

AIG12GQ13D

24 V/RS422(RS485) type

Pin name

+

FG

+SD

− SD

+RD

− RD

E

Name

+24 V

0 V

Functional ground

Send data

Send data

Receive data

Receive data

Terminal resistance

Signal direction

-

-

-

GT→External device(+)

GT→External device(−)

GT←External device(+)

GT←External device(−)

-

Product No.

AIGT2032B

AIGT2032H

AIGT2132B

AIGT2132H

AIG12MQ04D

AIG12MQ05D

AIG12MQ14D

AIG12MQ15D

AIG12GQ04D

AIG12GQ05D

AIG12GQ14D

AIG12GQ15D

Note:

There is no RS and CS (control lines).

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.2.5 GT21

24 V/RS232C type

24 V/RS422(RS485) type

Pin name

+

FG

SD

RD

RS

CS

SG

Pin name

+

FG

+SD

− SD

+RD

− RD

E

Name

+24 V

0 V

Functional ground

Send data

Receive data

Request to send

Clear to send

Signal ground

Name

+24 V

0 V

Functional ground

Send data

Send data

Receive data

Receive data

Terminal resistance

Note:

There is no RS and CS (control lines).

Signal direction

-

-

-

GT→External device

GT←External device

GT→External device

GT←External device

-

Product No.

AIGT2230B

AIGT2230H

Signal direction

-

-

-

GT→External device(+)

GT→External device(−)

GT←External device(+)

GT←External device(−)

-

Product No.

AIGT2232B

AIGT2232H

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.2.6 GT05/GT32/GT32-E

24 V/RS232C type

Pin name

+

FG

SD

RD

RS

CS

Name Signal direction

+24 V

0 V

Functional ground

Send data

-

-

-

GT→External device

Receive data GT←External device

Request to send GT→External device

Clear to send GT←External device

SG Signal ground -

Product No.

AIG05MQ02D

AIG05MQ03D

AIG05GQ02D

AIG05GQ03D

AIG05SQ02D

AIG05SQ03D

AIG32MQ02D

AIG32MQ03D

AIG32TQ02D

AIG32TQ03D

AIG32TQ12D

AIG32TQ13D

AIG32MQ03DE

AIG32TQ03DE

24 V/RS422(RS485) type

Pin name

+

FG

+SD

− SD

+RD

− RD

Name

+24 V

0 V

Functional ground

Send data

Send data

Receive data

Receive data

E

Terminal resistance

Signal direction

-

-

-

GT→External device(+)

GT→External device(−)

GT←External device(+)

GT←External device(−)

-

Product No.

AIG05MQ04D

AIG05MQ05D

AIG05GQ04D

AIG05GQ05D

AIG05SQ04D

AIG05SQ05D

AIG32MQ04D

AIG32MQ05D

AIG32TQ04D

AIG32TQ05D

AIG32TQ14D

AIG32TQ15D

AIG32MQ05DE

AIG32TQ05DE

Note:

There is no RS and CS (control lines).

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.3 Connecting to Screen Creation Tool GTWIN

2.3.1 TOOL Port

Pin No.

1

2

3

4

5

Name

Signal ground

Send data

Receive data

Not connected

+5 V

Abbre.

SG

SD

RD

N.C.

(+5V)

Signal direction

-

GT→External device

GT←External device

-

-

Note:

• The +5V of Pin 5 is reserved for the FP Programmer II. It should not be used for any other application.

If using it, there is a restriction on the ambient temperature. The pin 5 of GT01 is N.C.

2.3.2 USB Port

USB connection

Communication with our software such as GTWIN becomes available by connecting to a PC with a USB cable.

Functions enabled by USB connection

• Through function using our PLCs

• Screen transfer (The communication in a speed approximately 3 times of the one with the Ethernet connection is possible.)

Note: If more than one programmable display unit or AE20 are connected to a PC using the USB port, the communication is not available.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

2.3.3 Ethernet Port

Ethernet connection

GT32T1 has a Ethernet port. Communication with our software such as GTWIN becomes available by connecting to a PC with a LAN cable.

Ethernet communication function

• Screen transfer (Baud rate: fixed at 115200 bps. It takes at least 3 times longer than the transfer using

USB.)

• Through function using our PLCs

* Specifying the destinations to connect enables the communication with multiple units using a HUB.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Required items for connection

LAN cable

Either straight cable or crossing cable can be used.

(MDI/MDI-X Automatic crossover function)

Settings for Ethernet connection

Follow the procedure below to communicate with the Ethernet connection.

1. Connect the GT to a PC with a Ethernet cable.

2. Specify the settings such as IP address for the GT.

3. Startup the GTWIN and specify the communication condition.

The factory settings are as follows.

IP Address 192.168.1.5

Subnetmask

Default Gateway

Port No

255.255.255.0

192.168.1.

9094

Note) Setting items such as IP address for the GT can be specified in the System Menu.

GTWIN setting

Network type: Ethernet

Title: Input an arbitrary title (Up to 38 one-byte characters)

Computer:

Check “Acquire IP address automatically”.

The default setting is to use the IP address currently being used in the computer.

Click [OK] to finish the setting.

Note) When sing multiple Ethernet cards, specify manually.

IP address:

When it is not displayed, set the property of the TCP/IP in the items such as Network of the control panel. IP address can be input or changed.

Note) The setting procedure varies depending on the OS used. For the details, refer to the manual/help of the OS.

Port No.:

Set to 0 or within the range of 1025 to 32767 in decimal.

For using it in the GTWIN, set it to 0.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Setting of destination (PLC side)

IP address: Specify the IP address of the GT to be connected in decimal.

Port No.: Set it within the range of 1 to 32767 in decimal. (Default: 9094)

Specify the same setting as the one of GT.

Communication time out: Set the time-out period after connection establishment for every communication within the range of 1 to 950 seconds. (Default: 15) (it is not linked to this setting until a connection is estalished)

Connection time out: Set the time-out period until connection establishment within the range of 1 to 180 seconds. (Default: 60)

Setting with IP search tool (Config WD. exe)

The settings of the GT can be specified with the IP address search tool of Configurator WD (Ver.1.11 or later).

The IP search tool (Config WD. Exe) can be downloaded for free from our website

(User registration is required.: Free of charge)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Chapter 3

Installation and Wiring

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.1 Installation

3.1.1 Installation Environment

When installing and using the GT series, always make sure the following conditions are observed.

Usage conditions

Operating environment (Use the unit within the range of the general specifications when installing)

-

Ambient temperatures: 0 to +50 °C

-

-

-

-

(It varies according to models when installing the unit in a horizontal orientation or using a C-NET adapter and FP programmer II.)

Ambient humidity: 20 to 85% RH (at 25 °C, non-condensing)

Altitude of 2000 m or less

For use in pollution Degree 2 environment

Do not use it in the following environments.

- Direct sunlight, wind and rain. (This product is not designed for outdoor use.)

- Sudden temperature changes causing condensation.

- Inflammable or corrosive gas.

- Excessive airborne dust, metal particles or saline matter.

- Benzine, paint thinner, alcohol or other organic solvents or strong alkaline solutions such as ammonia

or caustic soda.

- Direct vibration, shock or places always exposed to drop of water.

(This unit is warranted by IP65/IP67 (depending on models) for panel mounting, however, this applies to initial values.)

- Influence from power transmission lines, high voltage equipment, power cables, power equipment,

radio transmitters, or any other equipment that would generate high switching surges. (100 mm or

more)

The usage conditions for Tough series (GT32-E) are as follows.

-

Ambient temperatures: -20 to +60 °C (When horizontally installed, -20 to +55 °C)

-

Ambient humidity: 10 to 90% RH (at 25 °C, non-condensing)

- The upper limit of the humidity at each temperature is as below.

(Below 40 °C; 90%RH, 50 °C; 55%RH, 60 °C; 35%RH)

- If the product is exposed to heavy rain, condensation might be caused by sudden temperature changes.

-

-

-

Altitude of 2000 m or less

For use in pollution Degree 2 environment

Do not use it in the following environments.

- Direct sunlight for a long time

(Exposing the product to direct sunlight increases the surface temperature of the display higher than ambient temperature, and causes deterioration of LDC panel.)

- Inflammable or corrosive gas.

- Excessive airborne dust, metal particles or saline matter.

- Benzine, paint thinner, alcohol or other organic solvents or strong alkaline solutions such as ammonia

or caustic soda.

- Direct vibration, shock or places always exposed to drop of water.

(This unit is warranted by IP67 for panel mounting, however, this applies to initial values.)

- Influence from power transmission lines, high voltage equipment, power cables, power equipment, radio transmitters, or any other equipment that would generate high switching surges. (100 mm or more)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

-

-

-

Static electricity

Do not touch connector pins directly to prevent static electricity from causing damage.

Always rid yourself of any static electricity before handling this product.

If excessive estatic electricity is applied to the panel surface, the LCD panel may be damaged.

-

-

-

-

Power supply

Twist the wires of the power supply.

The unit has sufficient noise immunity against the noise generated on the power line. However, it is recommended to take measures for reducing noise such as using an isolating transformer before supplying the power. And it is recommended to take measures such as installing a ferrite core.

Allocate an independent wiring for each power supplying line, PLC etc and operating device.

If using a power supply withoug a protective circuit, power should be supplied through a protective element such as fuse. Directly applying an abnormal voltage to the unit may cause the damage to the internal circuit.

Touch switches

-

Always operate the touch switch with fingers. As the touch switch may be damaged due to the excessive load or shock (caused when being operated with any tools), the touch switch should be operated within the specified control force. Also, if the touch swich is pressed like kneading, the electrode may be worn out exceptionally, and cause the malfunction. Operate with a single touch of the switch.

-

The touch position may shift due to aging variation. If the touch position has shifted, please adjust it.

LCD panel

-

Do not drop or have a strong impact on the programmable display unit as glass is used for the LCD

- panel.

The liquid in the LCD panel is a hazardous substance. If the LCD panel is broken, do not put the leaked crystalline liquid into your mouse. Should it get into your mouse, immediately gargle, and consult a doctor. If it adheres to your skin or clothes, wash it away with soap.

-

There is a case that shadows appear in the place on the screen of the GT where no graphic or part is arranged. (The shadows appear as the extension of the characters, graphics or parts actually being displayed.) This is a phenomenon resulting from the basic characteristics of liquid crystal devices, and

- called cross talk.

Exposing the product to direct sunlight increases the surface temperature of the display higher than ambient temperature, and causes deterioration of LDC panel. Screen the product from the sun.

3-3

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.1.2 Restriction According to Mounting Directions

If the unit is being installed in a horizontal orientation, or our Programmer II and C-NET adaptor are being connected to the TOOL port, note that the ambient usage temperature should be as below.

Model

Condition

Ambient name temperature

GT11

GT21

Vertically installed

Programmger II

C-NET adapter

Horizontally installed

Programmer II

C-NET adapter

GT32

Horizontally installed

GT32-E

Horizontally installed

0 to 45 C

0 to 40 C

-20 to 55 C

Note) When installing the unit aslant, the restriction is the same as the one when installing horizontally.

3.1.3 Installation Space

Applicable panel thickness

A panel with a thickness of 1.0 to 5.0 mm should be used.

Clearance when the GT is installed

When installing the GT unit, if other parts are being installed to the panel or cables are being wired to it, we recommend providing a clearance around the GT unit. This prevents cables from being damaged, and facilitates the installation work. Also, make sure that the slits in the main unit are never obstructed.

Clearance on the surface Clearance on the

Model name Clearance to connect the screen transfer cable mounting surface when using a SD memory card

GT01

GT11

GT21

GT02L

GT02

GT05

30 mm or more

(50 mm or more recommended)

20 mm

60 mm

-

-

GT12

GT32

60 mm 40 mm or more

GT32-E

* It should be 40 mm or more when using a SD memory card.

3.1.4 UL/c-UL Qualification

Be aware of the following when applying for UL standard for the equipment that the GT has been built in.

When the GT built in equipment, the GT should meet the standard as a part of the enclosure.

 As the rear of the GT is not qualified as an enclosure, provide a fire enclosure (metal barrier) that entirely covers the rear and lateral sides of the GT.

3-4

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.1.5 Mounting Screws

Secure the GT to a mounting plate using the fitting and screws provided with the unit.

Recommended screws

Recommended product

Mounting screw

GT unit

GT01/GT11

GT05/GT21/GT32/

GT32-E

Size Others

M3 – 20 Material: SW pane-head (+)

M3 – 3.5

Galvanization, trivalent chromate

Quantity

4 pcs/unit

GT02/GT02L/GT12 dedicated screw

The GT02/GT02L/GT12 dedicated screw is not sold on the open market.

Using screws other than the dedicated screw will cause failures such as decrease of water-proof property.

Name Content Model No.

Attachment fitting

(with dedicated screws)

5 sets for GT02/GT02L/GT12

4 pcs of attachment fittings and 4 pcs of dedicated screws/set

AIG12830

3-5

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.1.6 GT01 and GT11 Installation Method

Secure the GT to the installation panel using the four fittings and four screws provided with the unit.

1. Place the GT in the installation panel.

2. Insert the fittings into the grooves provided in the GT, and tighten the screws to secure the GT to the installation panel.

The screw tightening torque should be 0.1 to 0.25 N· m, and tighten them uniformly.

Tightening the scews too hard can cause deformation of the front panel, so that the touch switches will not function properly. Install the GT within the above range.

3.1.7 GT21 Installation Method

Secure the GT21 to the installation panel using the two fittings and four screws provided with the unit.

1. Place the GT21 main unit in the installation panel.

2. Insert the fittings into the grooves provided in the GT21 main unit, and tighten the screws to secure the GT21 main unit to the installation panel.

The screw tightening torque should be 0.1 to 0.25 N· m, and tighten them uniformly.

Tightening the scews too hard can cause deformation of the front panel, so that the touch switches will not function properly. Install the GT within the above range.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.1.8 GT05/GT32/GT32-E Installation Method

Secure the GT32 to the installation panel using the two fittings and four screws provided with the unit.

1. Place the GT main unit in the installation panel.

2. Insert the fittings into the grooves provided in the GT main unit, and tighten the screws to secure the GT main unit to the installation panel.

GT05 and GT32

The screw tightening torque should be 0.1 to 0.25 N· m, and tighten them uniformly.

GT32-E

The screw tightening torque should be 0.2 to 0.3 N· m, and tighten them uniformly.

Tightening the scews too hard can cause deformation of the front panel, so that the touch switches will not function properly. Install the GT within the above range.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.1.9 GT02/GT02L/GT12 Installation Method

Secure the GT12 or GT02 to the installation panel using the two fittings and four dedicated screws provided with the unit.

1. Place the GT main unit in the installation panel.

2. Insert the fittings into the grooves provided in the GT main unit, and tighten the screws to secure the GT main unit to the installation panel.

Note: - The cross slot screwdriver No. 1 must be used.

- Tightening torque: 0.2 to 0.3 N m

- Tightening the scews too hard can cause deformation of the front panel, so that the touch switches will not function properly.

3-8

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.1.10 Installing in Vertical Orientation

Normally, the GT series is installed horizontally long, however, some models can be installed vertically long. At that time, the right side becomes the upper side.

GT01 GT02 GT02L GT11 GT12 GT21

-

Note:

The side that the COM port is situated becomes the upper side. If the GT is installed upside down, the

- screen will be upside down.

The allowable ambient temperature for GT11 is different. (Ambient temperature: 0 to 45 °C)

Key Point:

Select the vertical type when selecting a GT model in GTWIN.

3.1.11 Precaution When reinstalling GT

When the GT is reinstalled after being removed from the panel, the water-proof packing should be replaced.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.2 Wiring the Power Supply

3.2.1 Wiring the Power supply

The power supply should be wired by securely connecting the terminal on the rear of the main unit to the terminal.

Use twisted wiring for the power supply

In order to minimize influence from noise, the wiring for the power supply should be twisted.

Insulate the power supply inside a protective circuit

• In order to protect the unit against abnormal voltage from the power supply line, the power supply should be an insulated type, and should be enclosed within a protective circuit.

• If a power supply device without an internal protective circuit is being used, power should always be supplied to the GT series through a fuse or a similar protective device.

Keep the power supply voltage within the operating voltage range

Rated voltage

5 V DC

24 V DC

Operating voltage range

4.5 to 5.5 V DC

21.6 to 26.4 V DC

Keep the power supply wiring separate

• Wiring to the GT series, PLC, and other power equipment should have separate wiring systems.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.2.2 Grounding

Be sure to ground when the influence of noise is great

The unit is tolerant against noise in normal environments, but if the environment is particularly susceptible to noise, please ground.

Use dedicated grounding

• For grounding purposes, use wires with a minimum of 2 mm resistance of less than 100 Ω.

2

. The grounding connection should have a

• Make the grounding point as close as possible to the GT and keep the distance of the grounding wire short.

• Sharing the ground with another device may have an adverse effect. Therefore, be sure that grounding is dedicated.

Note:

Conversely, depending on your environment, grounding may cause a problem.

Example:

Since the power line of the GT unit is connected to a functional earth via electronic parts, the electronic parts may become damaged if there is an abnormal potential between the power line and the physical ground.

Do not ground the function earth when grounding a plus (+) terminal of the power. (excluding

GT02, GT02L, GT05, GT12, GT32 and GT32-E)

In some computers, the SG terminal of RS232C port and connector shielding are connected. Also the tool port shielding is connected with the function earth terminal. Therefore, the GND terminal and the function earth terminal are connected if the computer is connected. Especially when the GT is connected to a computer with a plus (+) terminal grounded, therefore, an GT’s minus (-) terminal is connected with the function earth terminal. As a result, short circuit occurs which may lead to the breakage of GT and its neighboring parts.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.3 Wiring the COM Port

Accessory communication connector/applicable wiring

The communication connector used for the COM port (provided as an accessory with the main unit) has a screw-tightening type of terminal block. The wiring shown below should be used.

Applicable wiring (twisted wiring)

Size

AWG 28 to 16

Conductor cross-section surface area

0.08 to 1.25 mm

2

Use a special tool to tighten the terminal block of the communication connector.

Using a screwdriver made by Panasonic Electric Works Co., Ltd. (Product number: AFP0806). The tightening torque should be 0.22 to 0.3 N· m or less.

When doing RS485 communication using RS422 type

Please use the following cables or equivalent.

Appropriate electrical cables (twisted cables)

Conductor Insulator

Type

Cross-sectional view Size

Resistance

(at 20

°C)

Material

Thickness

Cable diam.

Sample appropriate cable

Shielded twisted pair

1.25 mm

2

(AWG16) or greater

0.5 mm

2

(AWG20) or greater

Max.

16.8

Ω

/km

Max.

33.4

Ω

/km

Polyethylene

Polyethylene

Max.

0.5 mm

Max.

0.5 mm

Approx.

8.5 mm

Approx.

7.8 mm

Belden 9860

Hitachi Cable,

Ltd. KPEV-

S1.25 mm

2

x

1P

Belden 9207

Hitachi Cable,

Ltd. KPEV-

S0.5 mm

2

x

1P

Note:

• Use shielded twisted pair cables.

• Use only one type of transmission cable. Do not mix more than 1 type.

• When using shielded cable with crossover wiring for the RS485 transmission line, grounded one end.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Wiring method

(1) Remove the sheath from the wire.

(2) Insert the wire all the way into the terminal block, and tighten the screw in the clockwise direction to secure it.

Precautions concerning wiring

The following precautions should be observed, to avoid broken or disconnected wires.

• When removing the sheath, be careful not to scratch the core wire.

• Wire the terminal without twisting the core wire.

• The core wire should be connected without soldering it. Vibration can sometimes cause soldered connections to break loose.

• After connecting the wiring, avoid subjecting the cable to stress.

• Because of the construction of the terminal, tightening the wire in the counterclockwise direction will cause a faulty connection. If this happens, disconnect the wire, check the terminal hole, and connect the wire again.

Reference:

For information on connecting the COM port of the GT series with various PLC units, refer to <Chapter 4

Connecting with the PLC>.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.4 Precautions when Wiring COM Port

Precautions are different depending on communication conditions. Arrange wirings according to the following instructions.

3.4.1 GT01 (5 V DC)

RS232C type

-

Perform wiring and placement of the cable so that there is no impression of external noise on the cable

- and no induction.

Use shielded wires for distribution cables.

-

(Recommended cable: AIGT8142 with one ferrite core)

It conforms to CE marking. As conditions, the following wiring is required.

1. Make the cable do three turns around a ferrite core.

(Recommended ferrite core: Seiwa Electric’s E04RA190120080 or equivalent)

2. Perform grounding of the cable shield.

* Packaged with AIGT8142.

RS422 (RS485) type

-

There is no RS and CS (control lines).

-

Perform wiring and placement of the cable so that there is no impression of external noise on the cable

- and no induction.

Use shielded wires for distribution cables.

-

(Recommended cable: AIGT8152 with one ferrite core(Seiwa Electric’s E04RA190120080))

When using shielded cable with crossover wiring for the RS485 transmission line, grounded one end.

-

“E” is used to set the terminating station.

-

It does not conform to European EMC directive.

Key Point:

The CE marking standards that the GT01 conforms to (excluding the RS422 (RS485) type)

European EMC directive 2004/108/EC

European EMC standards (EN61000-6-4 and EN61000-6-2)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.4.2 GT02/GT02L (5 V DC)

RS232C type

-

Perform wiring and placement of the cable so that there is no impression of external noise on the cable

- and no induction.

Use shielded wires for distribution cables.

-

(Recommended cable: AIGT8142)

It conforms to CE marking. As conditions, the following wiring is required.

1.Perform grounding of the cable shield.

2.Perform grounding of the GT.

GT02 GT02L

RS422 (RS485) type

-

There is no RS and CS (control lines).

-

Perform wiring and placement of the cable so that there is no impression of external noise on the cable

- and no induction.

Use shielded wires for distribution cables.

-

When using shielded cable with crossover wiring for the RS485 transmission line, grounded one end.

-

“E” is used to set the terminating station.

-

It conforms to CE marking. As conditions, the following wiring is required.

1.Perform grounding of the cable shield.

2.Perform grounding of the GT.

GT02 GT02L

Key Point:

The CE marking standards that the GT02/GT02L conforms to

European EMC directive 2004/108/EC

European EMC standards (EN61131-2)

3-15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.4.3 RS232C Communication

-

There is no RS and CS (control lines) for GT01.

-

Perform wiring and placement of the cable so that there is no impression of external noise on the cable

- and no induction.

Use shielded wires for distribution cables. (Recommended cable: AIGT8162)

-

It conforms to CE marking. As conditions, the following wiring is required.

1. Install a ferrite core to the cable. (For GT11 only)

(Recommended ferrite core: Seiwa Electric’s E04SR170730A or equivalent)

2. Perform grounding of the cable shield.

3. Perform grounding of the GT.

GT01/GT02/GT12 GT11

GT21 GT05/GT32/GT32-E

Key Point:

The CE marking standards that the GT series conforms to

European EMC directive 2004/108/EC

European EMC standards For GT01, GT11, GT21 (EN61000-6-4 and EN61000-6-2)

For GT02, GT12, GT05, GT32, GT32-E (EN61131-2)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.4.4 RS422 (RS485) Communication

-

There is no RS and CS (control lines).

-

Perform wiring and placement of the cable so that there is no impression of external noise on the cable

- and no induction.

Use shielded wires for distribution cables. (Recommended cable: AIGT8175 (for Mitsubishi FX series)

-

When using shielded cable with crossover wiring for the RS485 transmission line, grounded one end.

-

“E” is used to set the terminal unit.

-

It conforms to CE marking. As conditions, the following wiring is required.

1. Fit a ferrite core to the cable. (For GT11 only)

(Recommended ferrite core: Seiwa Electric’s E04SR170730A or equivalent)

2. Perform grounding of the cable shield.

3. Perform grounding of the GT.

GT11 GT01/GT02/GT12

GT21 GT05/GT32/GT32-E

Key Point:

The CE marking standards that the GT series conforms to

European EMC directive 2004/108/EC

European EMC standards For GT01, GT11, GT21 (EN61000-6-4 and EN61000-6-2)

For GT02, GT12, GT05, GT32, GT32-E (EN61131-2)

3-17

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.5 Precautions when Wiring Ethernet Port (GT32T1)

-

Although more than one GT32T1 can be connected using a hub, communication is performed with one

- unit each. Specify each destination to communicate.

Use a UTP cable (unshielded cable) for the Ethernet cable, and take measures for noises such as

- installing a ferrite core if necessary.

It conforms to CE marking. As conditions, the following wiring is required.

1. Do not use a shield wire for the Ethernet cable.

2. Install a ferrite core to the Ethernet cable and make one turn.

(Recommended ferrite core: Kitagawa Industries SFC-10 or equivalent)

GT32T1

Key Point:

The CE marking standards that the GT32 conforms to

European EMC directive 2004/108/EC

European EMC standards (EN61131-2)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.6 Options

3.6.1 Backup Battery

Backup battery

The internal data in the GT can be backed up using the backup battery.

Use the following backup batteries.

GT model Battery type

GT11

GT21

GT02M2,GT02G2

GT05

GT12

GT32

GT32-E

Button type lithium battery

Backup battery

CR2032 (commercial item)

AFPX-BATT

Product No.

(The backup battery for the FP-X is used.)

Battery life

Battery life, when operating at a normal temperature (25C), a normal humidity (65% RH), and a voltage of 24 V DC, is as follows.

GT model life

GT11

GT21

GT05S

GT32T *

GT32*-E

GT02M2,GT02G2

GT05M

GT05G

GT12

GT32M

Approx. 2 years

Approx. 3 years

Approx. 5 years

Backup

The internal data of the GT is backed up in the following ways.

Internal data to be backed up Stored in Backup battery

Screen data (base, keyboard, login)

Flow display data

Recipe data

Write device

FP monitor screen data

Alarm history + Line graph sampling

Logging data of Logging function

Hold GT device

Hold PLC device

Stored in the F-ROM. Not required

Stored in the SRAM. Required

Note:

When using a backup battery, attach the battery before the power supply is turned on.

3-19

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.6.2 How to Install the Battery (Lithium Button Battery)

(The figures below is explained using the GT11.

Note: Do not touch the electronic parts when removing and installing the battery.

3.6.3 How to Install the Battery (Backup Battery)

The figures below is explained using the GT32.

1. Remove the battery cover.

2. Connect the connector to make the red line be the (+) side, and place a battery in the circular frame.

3. Fit the battery cover.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

3.6.4 Dead Battery Mark

If the battery voltage drops too low, the battery mark is displayed at the bottom right of the GT screen.

When the battery voltage drops

It can be specified in the GTWIN configuration settings, whether or not the dead battery mark is displayed .

Note:

If the battery voltage drops too low, the BAT LOW flag of the basic communication area map goes on. If the battery has run down completely, the BAT flag of the basic communication area map goes on.

Please be aware that the BAT flag goes on the first time that the power supply is turned on after the unit is purchased.

* The BAT and BAT LOW flags in the basic communication area map activate in the both cases that the battery error display is set to “On” and “Off”.

3.6.5 Time for Replacement of Battery

When replacing the backup battery, turn on electricity for the time for energization, and replace the battery with a new one within one minute after turning off the power supply.

If the battery is not replced within the time for replacement, the saved data will be lost.

Time for energization

1 min. or more (10 min. or more for GT32)

Time for replacement

Within 1 min.

3.6.6 Replacement of Front Panel Protective Sheet

About the front panel protective sheet

Use the separately-sold protective sheets to protect the touch panel surface and to keep it clean.

Replacing the front panel protective sheet (For the type with protective film)

Follow the steps below to replace the sheet:

1. Peel off the seal from the provided protector sheet and attach it to the unit.

Take out one of the replacement front panel protective sheets and peel off the seal with the shiny side.

When attaching the sheet, align the adhesive edges with the front of the GT. Finish by peeling off the thin film attached to the top of the front panel protective sheet.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Replacing the front panel protective sheet (For the type without protective film)

1. Remove the peel-off film attached to the front panel protective sheet.

2. Attach the front panel protective sheet.

Attach the front sheet to fit the liquid crystal part of GT. At this time, try not to allow the air to get in the attached face. If the air was in, remove the air to be out with fingers. Do not press the front panel hard as it may cause the damage to the touch switch.

3.6.7 About the Waterproof Packing

If the panel is being detached from the GT and then reattached, the waterproof packing should be replaced, in order to assure that the panel remains waterproof (IP65, however, IP67 for GT02, GT12 and

GT32-E).

Replacing the waterproof packing

1. Remove the currently attached waterproof packing.

Remove the attached waterproof packing from the GT.

2. Attach the provided waterproof packing.

Take out one of the replacement waterproof packing pieces and attach the outer edge as shown in the illustration (do not use the inner edge).

When doing this, fasten it to the front frame, being sure not to twist the waterproof packing.

As for the model with a grooved front frame, surely fit the waterproof packing in the groove.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Chapter 4

Connecting with PLC

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.1 Connection with PLC

How to connect with PLC

Connecting between one GT and one PLC via 1:1 communication

Connecting between one GT and multiple PLCs via 1:N communication (PLC multiple

connection)

Connecting between one PLC and multiple GTs via 1:N communication (GT link)

Connecting using the general-purpose serial communication mode

As for the 5 V DC-type GT01, power can be supplied with a communication cable only.

4.1.1 PLC Multiple Connection

PLC multiple connection function is a function that enables more than one PLCs to connect with one GT.

4.1.2 GT Link Connection

GT link function is a function that enables more than one GT to connect with one PLC.

Wiring of Power Supply

It takes more than 5 seconds for all GT units to be operable after turning on the power supply of GT.

(The time varies according to conditions and the number of connected GT units.)

As for the power supply of GT, it is recommended to use the wiring that enables multiple GT units to be simultaneously turned on.

If the power supplies of multiple GT units cannot be simultaneously turned on after turning on the power supply of devices such as a PLC, an error message will be displayed and it may take some time to make communication to be established.

(The error display disappears when all the GT units become operable.)

4-2

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.1.3 Connecting to the PLCs made by Other Companies

For information on the connection with PLCs manufactured by other companies, see the latest GTWIN

HELP or our website where you can get the manual.

Reference:

< Connection with Other Companies' PLCs Manual ARCT1F449E>

4.1.4 Connecting to a Serial Device

Devices other than PLCs can be connected by using the general-purpose serial communication mode of the GT. Also, PLCs made by other companies which are not put on our website can be used. See our website or the GT series General-purpose serial communication manual.

Reference:

<GT Series General-purpose Serial Communication Manual ARCT1F356E>

4.1.5 Electric Supply from PLC (5 V DC-type )

The power can be supplied to the 5V DC-type with the communication cable only. The power supply is not required separately. However, it is available only when it is connected with the

TOOL port.

Restriction on the capacity of the power supply depending on the PLC model to be used

The number of PLC units that can be expanded is limited.

FP-X

FP0

FPΣ

FP2

PLC model

FP2SH

Restrictions when connecting a 5 V DC-type

The number of units which can be expanded depends on the unit type.

Maximum of two expansion units *

Maximum of six expansion units *

The method for calculating the number of units that can be expanded is provided in the manual. Follow that formula and keep the GT01’s power consumption not higher than 200 mA when calculating.

FP-e/FP0R

FX series made by

Mitsubishi Electric

Co.

There are no particular restrictions.

The restrictions are equivalent to the restrictions on the programmable display

F920 (5 V power supply type) made by Mitsubishi.

Use the FX series according to the use conditions for the F920 (5 V power supply type).

* Expansion is possible with the number of units given above, regardless of the type of unit.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.2 RS232C Connection

4.2.1 Difference of Terminal blocks Between GT Models

Although the terminal blocks vary according to the GT models, the connection method is the same.

The connection diagram for 24 V DC is described with the terminal blocks other than the one for GT01.

24 V DC type 24 V DC-type GT01 other than GT01

5 V DC-type GT01 5 V DC-type GT02/GT02L

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.2.2 RS232C Connection with PLC Tool Port

Connecting with 5 V DC type

Usable models

PLC

FP-X

FPΣ

FP0/FP0R

FP-e

FP2/FP2SH

PLC communication cable

Mini-DIN 5-pin loose-wire cable

Connecting to the TOOL port

AIGT8142

Programmable display

5 V DC type RS232C type

-

Note: Connecting to the COM port is not available.

Keep the cable no longer than 3 m.

-

In case of connecting to PLC with all expansion slots used, prepare an external 5 V DC power supply

- for the GT01 due to current consumption limits.

When using the FP2/FP2SH, check whehter or not the power can be supplied from the TOOL port according to the calculation method of the number of expansion units described in the hardware manual.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Connecting with 24 V DC type

Usable models

PLC

FP-X

FPΣ

FP0/FP0R

FP-e

FP2/FP2SH

PLC communication cable

Mini-DIN 5-pin loose-wire cable

Connecting to the TOOL port

AIGT8162

AIGT8165

AIGT8160

Programmable display

24 V DC RS232C type

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.2.3 RS232C Connection with FP-X COM Port

Connecting to the COM port of FP-X Communication cassette

Usable models

PLC

FP-X

AFPX-COM1

AFPX-COM2

AFPX-COM3

AFPX-COM4

AFPX-COM5

PLC communication cable

Loose-wire cable

Connecting to the 1- channel type RS232C

Programmable display

5 V DC

24 V DC

RS232C type

Connecting to the 2-channel type RS232C

As for the connection to S2 and R2 for COM2, make the same connection as S1 and S2.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Connecting to the 1-channel type RS485 and 1-channel type RS232C

Connecting to the 1-channel type Ethernet and 1-channel type RS232C

It cannot be connected with Ethernet.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.2.4 RS232C Connection with FP

Σ COM Port

Connecting to the COM port

Usable models

PLC PLC communication cable

FPΣ Loose-wire cable

Connecting to the 1-channel type RS232C

5 V DC

24 V DC

Programmable display

RS232C type

Connecting to the 2-channel type RS232C

As for the connection to S2 and R2 for COM2, make the same connection as S1 and S2.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Connecting to the 1-channel type RS485 and 1-channel type RS232C

The connections with either one unit or two units are available.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.2.5 RS232C Connection with FP0/FP0R COM Port

Connecting to the COM port

Usable models

PLC PLC communication cable

FP0

FP0R

RS232C type

Connecting to the COM port of FP0/FP0R

5 V DC

24 V DC

Programmable display

RS232C type

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.2.6 RS232C Connection with FP-e COM Port

Connecting to the COM port

Usable models

PLC

FP-e

PLC communication cable

Loose-wire cable

Connecting to the FP-e (RS232C)

Programmable display

5 V DC

24 V DC

RS232C type

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.2.7 RS232C Connection with FP2/FP2SH COM Port

Connecting to the COM port

FP2/FP2SH CPU unit

FP2 Computer Communication Unit

FP2 Multi Communication Unit

Usable models

PLC

FP2/FP2CH CPU unit

FP2 Computer Communication Unit

FP2 Multi

Communication

Unit

Communication block

FP2-CB232

Connecting to the TOOL port

PLC communication cable

D-SUB 9-pin loose-wire cable

Programmable display

AIP81842 5 V DC

24 V DC

RS232C type

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.3 RS422 Connection

4.3.1 Difference of Terminal blocks Between GT Models

Although the terminal blocks vary between the 5 V DC type and 24 V DC type, the connection method is the same.

The connection diagram is described with the terminal block for 24 V DC.

24 V DC type 5 V DC-type GT01 5 V DC-type GT02/GT02L

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.3.2 RS422 Connection with FP-X COM Port

Usable models

PLC

FP-X AFPX-COM3

PLC communication cable

Loose-wire cable

Programmable display

5 V DC

24 V DC

RS422/RS485 type

Connecting to the FP-X Communicatoin cassette, 1-channel type RS485/RS422

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.3.3 RS422 Connection with FP2/FP2SH COM Port

Connecting to the COM port

Usable models

FP2 Multi

Communication

Unit

PLC

Communication block

FP2-CB422

PLC communication cable

D-SUB 9-pin loose-wire cable

AIP81842

Programmable display

5 V DC

24 V DC

RS422/

RS485 type

Connecting to the FP2 Multi Communication Unit (MCU) + Communication block (RS422)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.3.4 RS422 Connection with C-NET Adapter

Usable models

PLC

FP series

PLC communication cable

C-NET adapter

AFP8536

AFP8532

AFP15401

AFP15402

Conneciton method

Programmable display

5 V DC

24 V DC

RS422/RS485 type

Communication settings on the PLC side

Specify the setting to match with the setting for the GT using the tool software at the PLC side.

C-NET adapter setting

Set the termination (TERMINATE) to on.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.4 RS485 Connection

4.4.1 Difference of Terminal blocks Between GT Models

Although the terminal blocks vary between the 5 V DC type and 24 V DC type, the connection method is the same.

The connection diagram is described with the terminal block for 24 V DC.

24 V DC type 5 V DC-type GT01 5 V DC-type GT02/GT02L

Note) RS485 communicatoin is performed using the RS422 terminal blocks.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.4.2 RS485 Connection with FP0R COM Port

Connecting to the COM port

Usable models

PLC

FP0R RS485 type

PLC communication cable

Loose-wire cable

Programmable display

5 V DC

24 V DC

RS422/RS485 type

Connecting to the COM port of FP0R

4-19

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.4.3 RS485 Connection with FP-X COM Port

Usable models

PLC

FP-X

AFPX-COM3

AFPX-COM4

AFPX-COM6

PLC communication cable

Loose-wire cable

5 V DC

Programmable display

24 V DC

RS422/RS485 type

Connecting to the FP-X Communicatoin cassette, 1-channel type RS485/RS422

Note: Check the usable GT models for 1:N communication.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Connecting to the 1-channel type RS485 and 1-channel type RS422

Note: Check the usable GT models for 1:N communication.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Connecting to the 2-channel type RS485

Note: Check the usable GT models for 1:N communication.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.4.4 RS485 Connection with FP

Σ COM Port

Connecting to the COM port

Usable models

PLC

FPΣ

AFPG803

AFPG806

PLC communication cable

Loose-wire cable

Connecting to the 1-channel type RS485

5 V DC

24 V DC

Programmable display

RS422/RS485 type

Note: Check the usable GT models for 1:N communication.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Connecting to the 1-channel type RS485 and 1-channel type RS232C

Note: Check the usable GT models for 1:N communication.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.4.5 RS485 Connection with FP-e COM Port

Connecting to the COM port

Usable models

PLC

FP-e RS485 type

Connecting to the FP-e (RS485)

PLC communication cable

Loose-wire cable

Programmable display

5 V DC

24 V DC

RS422/RS485 type

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.4.6 RS485Connection with FP2/FP2SH

Usable models

FP2 Multi

Communication

Unit

PLC

Communication block

FP2-CB485

PLC communication cable

Loose-wire cable

Programmable display

5 V DC

24 V DC

RS422/

RS485 type

Connecting to the FP2 Multi Communication Unit (MCU) + Communication block (RS485)

Note: Check the usable GT models for 1:N communication.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.4.7 Precautions When Communicating With RS485

When communication with the RS485, the transmission line for sending and receiving data is the same.

Time taken until the connected device sends a response after sending a command from the

GT:

If a response is sent too quickly, the GT may not be able to receive it. Adjust the time if necessary.

For our FP series FPΣ or FP-X, the time can be specified using the SYS1 instruction.

Time taken until the GT sends a next command after receiving a response:

If a command is sent to quickly, the connected device may not be able to receive it.

The time can be specified in the delay time setting for transmission in the communication parameter of the GTWIN configuration setting.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.5 Connection With a PLC

4.5.1 Automatic Communication Settings Function

After turning on the power supply, if there is not response from the PLC connected to the GT, the GT switches to the automatic setting mode for the communication conditions. In the automatic setting mode, commands are sent to the PLC while changing the communication conditions in the sequence shown below.

The GT, in automatic setting mode, continues to repeat steps to until there is a response from the

PLC. While it is repeating there steps, it is in the “Standby” mode under “Configuration” →

“Communication Parameters” → “Handle Communication Error” on GTWIN.

Explanation of this function:

-

Conditions when the automatic settings mode is in effect

If communication is attempted the specified number of times and there is no response from the PLC, the GT goes into the automatic settings mode. The number of attempts is specified using the “No. of

Retries” parameter under “GT Configuration” → “Communication Parameters” → “Handle

Communication Error” on GTWIN.

-

Automatically set communication conditions

In the automatic settings mode, if there is a response from the PLC, subsequent communication is carried out under conditions matching the response. The main unit configuration settings are not updated, however, even if the communication parameters are different from those of the main unit configuration settings.

-

Note:

An error response from the PLC is taken as a response, and the GT does not go into the automatic

- settings mode.

If the unit is connected to the COM port of the FP0/FP1/FP2/FP2SH/FP-M, communication between the

FP device and the PLC will not be possible if the target usage of the RS232C port has not been set to

“Computer Link”. Always set the setting on the PLC side to match “Computer Link”.

-

The automatic communication settings function cannot be used for the communcation at 230400 bps on the GT01, GT11 or GT21.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.5.2 Through Function

With the GT series, communication can be set to take place automatically between the COM port of a

GT and TOOL port of a PLC in a “through function”. When the FP series tool software installed in the computer connected to the GT series as shown below is booted, PLC programs can be edited through the GT series. The through function does not require any special settings, and is always in the standby mode.

For TOOL port type

For USB port type

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Note:

Precautions when using the through function

The system should be set up so that the Timeout period in the FP series software (FPWIN) (A) is larger than the waiting time for communication retries of the GT COM port (B), meaningn (A) > (B). If the system is set up so that A = B or A < B, the through function will not work properly.

When the baud rate of the GT TOOL port is 230400 bps, the through function cannot be used.

Communicate at 115200 bps or lower for using the throught function.

• For the USB port type, the OS installed in the connected computer must be Windows2000 or later.

Restrictions on COM port connections

When connecting the GT01 to the COM port of a PLC, a separate external supply must be provided.

When using the FP programmer II

An FP Programmer II cannot be connected to the tool port of the GT01. It can be connected to the

GT11 and GT21. The GT32 cannot be connected to the FP programmer II as it is connected with USB or Ethernet.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

4.5.3 How to Make Communication Settings Using the FPWIN GR

Please read below to make PLC communication settings using the FPWIN GR.

1. Select “PLC system register setting” from the Option menu (O).

2. The window below will be displayed.

Select “Tool port setting” when connecting to the tool port or “COM port setting” when connecting to the

COM port. Please match the transfer format and transmission speed settings to those of the GT.

In addition to the transfer format and transmission speed settings, set the communication mode to

“Computer link” when using the COM port.

Select “Computer Link”.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Chapter 5

Troubleshooting

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

5.1 What to DO If Something Unusual Occurs (GT01/GT11/

GT21)

Problem

Screen is blank

1) Power is not on.

Cause

2) (When only lamp and message parts are configured to the base screen) Value of substitute reference device value does not exist in substitute data.

An error has occurred in communication between the GT and an external device (e.g.

PLC).

Solution

1) Supply the power supply to unit as per specifications.

2) Check the address of the substitute reference device and the device values on the PLC side.

Refer to <5.3 Troubleshooting Error Codes>. Error code

[ER**] appears at the top right of the screen

Screen displays [No

Screen data]

Screen displays

[Screen No.

Error]

Screen displays

[Memory is

Full]

There is no base screen data in the GT.

(Appears even when GT configuration data exists.)

1) Screen settings from the PLC, the GT’s switch part or the auto-paging indicate an unregistered screen number.

2) When bringing up the keyboard screen during data input, an unregistered keyboard screen number was specified.

3) GT configuration data and keyboard screen data exist in the GT, but there is no base screen data.

The total capacity of transferred base screen data exceeds the 384 kbyte capacity of the

GT.

Transfer base screen data.

1) Create and register screen content or specify the correct screen number.

2) Create and register keyboard screen or specify the correct keyboard number.

3) Transfer base screen data from GTWIN.

Delete part of the base screen data so that the capacity doesn’t exceed the total capacity.

Data capacity can be checked by going to [View

(V)]→[Memory Usage Conditions] on GTWIN menu bar. When the data capacity is not over the limit, invalid data could possibly be remaining in the GT.

When transferring data, do so after deleting the screen.

1) Specify the correct screen number. An unspecified screen appeared/th ere is trouble when switching screens.

1) The screen specification in the PLC screen setting, the GT switch part or the auto-paging is wrong.

2) The startup screen is specified in the GT configuration settings (GTWIN).

3) An erroneous device or value is specified in the first word of the basic communication area word device.

2) Check the start-up screen setting for the GT configuration settings in GTWIN. Delete unnecessary settings and re-transfer configuration data.

3) Check the device content specified on the PLC side in the first word of the basic communication area. (Do not use the basic communication area with ladder programs.)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Problem

Screen doesn’t switch

Cause

1) No screen number has been written to the screen setting area (the first word in the basic communication area word device) from the PLC.

2) The screen number to which you are attempting to switch has already been written from the PLC to the screen setting area (the first word in the basic communication area word device.)

1) The power voltage may be low. Screen is dim

2) The contrast is set too low.

3) The backlight brightness is set too dark.

4) The backlight is off due to the

[Backlight Auto-off] setting in the

[Setup] of the GT configuration settings in GTWIN.

1)The backlight auto-off timer setting is too short.

Backlight goes off too quickly

Date/time display is incorrect

Touch panel doesn’t work

1) The PLC’s internal calendar timer used as a reference is incorrect.

No operating sounds are heard when the touch panel is pressed.

Nothing happens for about 10 seconds after turning on power.

1) Valid conditions have been set for the switch part, but those conditions have not been met.

1) The [Switch Sounds] setting under

[Options] in the switch part attributes is set to [Disabled].

2)The [Touch Sounds] setting under

[Setup] in the GT configuration settings in GTWIN is set to [Disabled].

Communication conditions of GT (COM port) and PLC differ.

Solution

1) Specify correct screen number.

2) Refer to Reference Manual.

1) Check the capacity of the power supply unit if it is enough for the GT’s power consumption.

2) Bring up the system menu and adjust the contrast.

3) Bring up the system menu and adjust the brightness.

4) Touching any area of the screen lights that area. If a switch part is set on the touched area, the area will not light even if touched. To change the setting, change the content of the backlight auto-off settings.

1) Change the backlight auto-off timer setting.

1) Adjust by rewriting the value in the PLC’s internal calendar timer.

1) Check that the device status conditions on the PLC side are valid.

1) Change the setting to [Enabled].

2) Change the setting to [Enabled].

Verify communication settings of GT and PLC and then make them the same.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Problem

Buzzer sounds continuously

Backlight color changes/ flashes

Cannot transfer data from

GTWIN

- Screen is blank

(power supply and substitution settings noted above do not apply)

- An incorrect screen is displayed

(error codes and erroneous date and time items noted above do not apply)

- Switch doesn’t work (grid and validity settings noted above are correct)

- Buzzer sounds continuously

Cause

Bit F of the first word in the basic communication area bit device is set to ON.

Bits A and B, and Bit D, of the first word (backlight color setting) in the basic communication area bit device are set to ON. Or, Bits C and D

(backlight flashing setting) are set to

ON.

1) The screen transfer cable is not connected.

2) The PC and GT COM port are connected.

3) The TOOL port of the GT has been set to 230400 bps.

4) The network type in the communication settings has been set to either “Ethernet” or “USB”.

An error has occurred in the GT system.

Solution

Set the F bit to OFF on the PLC side. (Do not use the basic communication area with ladder programs.)

Perform correct bit operations on the PLC side. (Do not use the basic communication area with ladder programs.)

1) Confirm that the screen transfer cable is correctly and firmly connected.

2) Connect to TOOL port with screen transfer cable.

3) Set the baud rate for the GTWIN communication condition to 230400 bps before transfer data.

4) Set the network type in the communication settings to “RS232C”.

1)

After confirming the safety of the device, etc., turn off the power supply and then turn it on again. The

GT CPU will be reset.

2)

If 1) produces no change, bring up the system menu and initialize the memory (F-ROM), then transfer data again from GTWIN to the GT.

NOTE:

When doing this, all base screen data, GT setting data, keyboard screen data, and bitmap data will be lose. Before doing this, make sure all data has been backed up.

3)

If 2) produces no change, set the operating mode setting switches 2, 3 and 4 on the rear of the main unit to ON and reset the power supply.

NOTE:

When doing this, all of the contents will revert to those in effect at the time of shipping, and all of the

GT memory contents will be cleared. Before doing this, make sure all data has been backed up.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

5.2 What to DO If Something Unusual Occurs

(GT02/GT02L/GT05/GT12/GT32/GT32-E)

Problem Cause

Screen is blank 1) Power is not on.

Error code

[ER****] appears at the top right of the screen

Screen displays

[No Screen data]

2) (When only lamp and message parts are configured to the base screen)

Value of substitute reference device value does not exist in substitute data.

An error has occurred in communication between the GT and an external device

(e.g. PLC).

Screen displays

[Screen No.

Error]

Screen displays

[Memory is Full]

An unspecified screen appeared/there is trouble when switching screens.

Screen doesn’t switch

Solution

1) Supply the power supply to unit as per specifications.

2) Check the address of the substitute reference device and the device values on the PLC side.

Refer to <Troubleshooting Error Codes>.

There is no base screen data in the GT.

(Appears even when GT configuration data exists.)

1) Screen settings from the PLC, the GT’s switch part or the auto-paging indicate an unregistered screen number.

2) When bringing up the keyboard screen during data input, an unregistered keyboard screen number was specified.

3) GT configuration data and keyboard screen data exist in the GT, but there is no base screen data.

-

The total capacity of transferred base screen data exceeds the memory capacity of the GT.

1) The screen specification in the PLC screen setting, the GT switch part or the auto-paging is wrong.

2) The startup screen is specified in the

GT configuration settings (GTWIN).

3) An erroneous device or value is specified in the first word of the basic communication area word device.

1) No screen number has been written to the screen setting area (the first word in the basic communication area word device) from the PLC.

2) The screen number to which you are attempting to switch has already been written from the PLC to the screen setting area (the first word in the basic communication area word device.)

Transfer base screen data from GTWIN.

1) Create and register screen content or specify the correct screen number.

2) Create and register keyboard screen or specify the correct keyboard number.

3) Transfer base screen data from GTWIN.

4) Press [ESC] button to return to the previous screen.

Delete part of the base screen data so that the capacity doesn’t exceed the total capacity.

Data capacity can be checked by going to [View

(V)]→[Memory Usage Conditions] on GTWIN menu bar. When the data capacity is not over the limit, invalid data could possibly be remaining in the GT. When transferring data, do so after deleting the screen.

1) Specify the correct screen number.

2) Check the start-up screen setting for the GT configuration settings in GTWIN. Delete unnecessary settings and re-transfer configuration data.

3) Check the device content specified on the PLC side in the first word of the basic communication area. (Do not use the basic communication area with ladder programs.)

1) Specify correct screen number.

2) Refer to Reference Manual.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Problem

Screen is dim

No operating sounds are heard when the touch panel is pressed.

(Except GT02L)

Nothing happens for about 10 seconds after turning on power.

Cause

1) The power voltage may be low.

2) The contrast is set too low.

3) The backlight is off due to the

[Backlight Auto-off] setting in the

[Setup] of the GT configuration settings in GTWIN.

Backlight goes off too quickly

Date/time display is incorrect

(when using the

GT’s internal clock)

Date/time display is incorrect

(when using the

PLC’s internal calender timer)

Hold PLC

Device data content isn’t saved

Date/time display is incorrect

Touch panel doesn’t work

3) The battery has run down.

1) The PLC’s internal calendar timer used as a reference is incorrect.

1) No battery has been inserted.

2) The battery has run down.

1) The PLC’s internal calendar timer used as a reference is incorrect.

Solution

1) Check the capacity of the power supply unit if it is enough for the GT’s power consumption.

2) Bring up the system menu and adjust the contrast.

3) Touching any area of the screen lights that area. If a switch part is set on the touched area, the area will not light even if touched. To change the setting, change the content of the backlight auto-off settings.

1) Change the backlight auto-off timer setting. 1)The backlight auto-off timer setting is too short.

1) The GT’s internal clock used as a reference is incorrect.

2) No battery has been inserted.

1) Adjust the clock from the system menu.

2) Purchase a battery and install it.

3) Replace the battery.

1) Adjust by rewriting the value in the PLC’s internal calendar timer.

1) Purchase a battery and install it.

2) Replace the battery.

1) Adjust by rewriting the value in the PLC’s internal calendar timer.

1) Valid conditions have been set for the switch part, but those conditions have not been met.

1) The [Switch Sounds] setting under

[Options] in the switch part attributes is set to [Disabled].

2)The [Touch Sounds] setting under

[Setup] in the GT configuration settings in GTWIN is set to

[Disabled].

Communication conditions of GT

(COM port) and PLC differ.

1) Check that the device status conditions on the PLC side are valid.

1) Change the setting to [Enabled].

2) Change the setting to [Enabled].

Verify communication settings of GT and PLC and then make them the same.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Problem

Buzzer sounds continuously

Backlight color changes/ flashes

Cannot transfer data from

GTWIN

Cause

Bit F of the first word in the basic communication area bit device is set to ON.

Bits A and B, and Bit D, of the first word (backlight color setting) in the basic communication area bit device are set to ON. Or, Bits C and D

(backlight flashing setting) are set to

ON.

1) The USB or LAN cable (GT32T1) is not connected.

2) The PC and GT COM. port are connected.

3) The network type in the communication settings has been set to “RS232C”.

Solution

Set the F bit to OFF on the PLC side. (Do not use the basic communication area with ladder programs.)

Perform correct bit operations on the PLC side. (Do not use the b asic communication area with ladder programs.)

1) Confirm that the screen transfer cable is correctly and firmly connected.

2) Connect the USB cable or LAN cable (GT32T1) correctly.

3) Set the network type in the communication settings to “Ethernet” for using a LAN cable.

Set the network type to “USB” for using a USB cable.

1)

After confirming the safety of the device, etc., turn off the power supply and then turn it on again. The

GT CPU will be reset.

- Screen is blank

(power supply and substitution settings noted above do not apply)

- An incorrect screen is displayed

(error codes and erroneous date and time items noted above do not apply)

- Switch doesn’t work (grid and validity settings noted above are correct)

- Buzzer sounds continuously

No sound is output.

An error has occurred in the GT system.

1) The speaker is not connected.

2) The setting for using sound is not on.

2)

If 1) produces no change, bring up the system menu and initialize the memory (F-ROM), then transfer data again from GTWIN to the GT.

NOTE:

When doing this, all base screen data, GT setting data, keyboard screen data, and bitmap data will be lost. Before doing this, make sure all data has been backed up.

3)

If 2) produces no change, set the operating mode setting switches 2, 3 and 4 on the rear of the main unit to ON and reset the power supply.

NOTE:

When doing this, all of the contents will revert to those in effect at the time of shipping, and all of the

GT memory contents will be cleared. Before doing this, make sure all data has been backed up.

1) Connect an audio output equipment (speaker with a built-in φ3.5-mini plug amplifier).

2) Set the sound setting of the GTWIN configuration settings to be on.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Operation security function

Message

“Incorrect password.” Is displayed on the login screen.

“Incorrect password.” Is displayed on the password change screen.

“Please verify your password again.” Is displayed on the password change screen.

“Use another password.”

Is displayed on the password change screen.

“Password setting incomplete.” Is displayed on the password change screen.

“Your password cannot be deleted.” Is displayed on the password management screen.

“Your level cannot be changed” is displayed on the password management screen.

Cause

An unregistered password was entered.

An incorrect password was entered in the Current password field.

The entered New password and

Confirm password are different.

The password that has been already registered is tried to be registered.

There are items that are not entered.

Your password was tried to be deleted.

Your level was tried to be changed.

Solution

Enter the registered password.

Enter the registered password correctly.

Enter the same password in the New password and

Confirm password fields.

Enter an unregistered new password.

Enter all items.

Your password cannot be deleted. If you want to delete it, delete from the “Operation security password edit" on

GTWIN.

Your level cannot be changed.

If you wanto to change it, change from the “Operation security password edit” on

GTWIN.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

When using the SD memory card.

Data may be erased or the SD memory card may be damaged during the operation. Take measures for the situations as below.

Problem Measures

Data in SRAM

(Record area for logging) is lost.

SD memory card is damaged and data cannot be read

Transmitting GT configuration setting file using the logging function clears the information on the SRAM.

Save all the data remained in the log before transmission.

When data cannot be saved in the SD memory card, the data beginning with the chronologically oldest data will be overwritten if the record area for logging is full.

Make the setting of the notice device for the case that the SD card free space is less than the specified size.

Stop the logging of data.

Eject the SD memory card after turning on the setting for stopping the trigger occurrence for all logging files in the record area control.

(Activate the setting for stopping the trigger occurrence with switch parts, etc.)

because SD memory card was ejected during save.

Set not to save in the SD memory card.

Turn on the control device for stopping write to the SD memory card, and then eject the card.

A UPS (Uninterruptible power source) is used. When using a UPS, the power is supplied to the PLC and GT both from the UPS, and the signal for logging stop/file creation is sent to the GT from the PLC using the power failure alarm signal that is input into the PLC as a trigger. (See figure below.)

SD memory card is damaged by power discontinuity due to power failure and data cannot be read

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

5.3 Error Codes and How to Handle Them

5.3.1 About Error Codes

When an error occurs in the GT series, an error code displays at the top right of the screen. There are two types of error codes, GT series error codes and PLC error codes.

5.3.2 GT Series Error Codes

The following error codes are displayed when there is an error in the GT.

For GT01, GT11 and GT21

Code No.

ERFF

ER21

ER22

Content

Time up error

No response from the

PLC.

Data error

A data error occurred during communication.

Overrun error

The GT cannot receive data.

Cause and solution

1) The PLC connection cable is disconnected. Check the connection cable to make sure it is connected.

2) There is a temporary error due to noise, etc. Re-supply power to the PLC and GT.

1) An error exists in the communication condition settings.

Check the PLC and GT baud rate and transfer format.

2) There is a temporary error due to noise, etc. Re-supply power to the PLC and GT.

The reception buffer in the GT is overflowing.

There could be an error in the PLC

Re-supply power to the PLC and GT.

For GT02, GT02L, GT05, GT12, GT32 and GT32-E

Code No. Content

**00FF Time up error

**0100

**0101 Alarm history error

**0500 Tool setting error

**1000

**1001

Keyboard screen data parts digit error

SD memory card not inserted

SD memory card writing error

Cause and solution

1) The PLC connection cable is disconnected. Check the connection cable to make sure it is connected.

2) There is a temporary error due to noise, etc. Re-supply power to the PLC and GT.

Check if the digit of the data parts on the keyboard screen has been set correctly.

When updating the alarm history display is stopped, alarm history data displayed on the GT’s screen has been updated within the memory. Once the stop of display update is cancelled, new data is displayed.

The device that cannot be used is specified for the data. Check if the used device is correct. (e.g. the word device is set in the bit area.)

The SD memory card is not inserted to the SD memory card slot properly. Check the SD memory card slot.

Data cannot be written to the SD memory card. Check whether the SD memory card is not write-protected.

5-10

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Code No.

**1002

**1003

**1005

**1006

**1020

**1021

**1022

**1023

**1025

Content

SD memory card memory full

SD memory card reading error

SD memory card saved file name error

SD memory card recognition error

PLC model unmatch error

PLC model unsupported error

Password protection error

Master memory installation error

General-purpose memory shortage

**1027 Remote mode error

**102D Forced operation error

**1040

**1041

**1042

**1044

**1043

**1045

The record area for logging was overwritten.

SD memory card writing error

The record area for logging cannot be reserved in the

SRAM.

Cause and solution

Data cannot be written as the memory of the SD memory card has been exhausted. Delete some data in the SD memory card or prepare a new SD memory card.

The data in the SD memory card cannot be read.

Check whether the saved data in the SD memory card is not damaged with a PC.

The file name to be saved to the SD memory card from the GT is not specified properly. Specify the file name properly.

The SD memory card cannot be recognized.

Check the SD memory card used.

Check if the PLC program for transfer matches the destination

PLC.

The selected PLC model is not supported. Confirm the PLC model.

(1) Incorrect passwords were input three times or more. Input the correct password after turning the power supply off and then on again.

(2) The upload protection has been set for the PLC.

(3) The number of digits was changed when setting a new password with the FP monitor function. Cancel the password setting first to change the number of digits.

A master memory is installed in the PLC (FP-X).Programs cannot be transferred to the PLC with the master memory from a SD memory card.

General-purpose memory shortage in the destination PLC.

The PLC (FP2/FP2SH) is set to the RUN mode. Change to the

REMOTE mode or PROG. mode.

Check if a device that cannot be forcibly operated in the PROG. mode has been forcibly turned on or off.

A SD memory card is not inserted.

Check the SD memory card slot.

Data cannot be written into the SD memory card. Check whether the SD memory card is not write-protected.

As the memory of the SD memory card has been exhausted.

Delete some data in the SD memory card or prepare a new SD memory card.

The setting to stop writing to SD memory card has been set.

Cancel the writing stop setting.

The setting to stop writing to SD memory card has been set.

Cancel the writing stop setting.

Transfer all data.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Code No. Content

**1060

**1080

**2000

Index register value error

Start time device value error

Connected GT designation area error

The bit corresponding to the connected GT in the connected GT designation area.

**20FF Token error

There is a GT unresponsive to the token.

**F000 User’s memory error

Cause and solution

The device value for index modifier is out of the setting range.

Check the setting value.

The value at the start of the line graph function is out of the setting range. Check the setting value.

The bit in the connected GT designation area corresponding to the station number of the connected GT is not on.

Check the connected GT designation area.

When the error code is indicated for a certain period of time after the power supply turned on.:

1. The timings for turning on multiple GT units are different.

Arrange the wiring that enables the power supplies to be simultaneously turned on.

2. The screen displays for all GT units have not completed.

The error code disappears when the screen displays for all

GT units have completed.

3. The settings for the startup screen display vary.

Make the same setting for all the connected GT units.

When the error code is always indicated:

1. There is an unconnected or faulty GT.

Check if there is a GT indicating [**20FF]. Reconnect the GT, or turn off the bit in the connected GT designation area.

2. The communication parameters are not specified correctly.

Check the baud rate and transmission format for the GT.

3. The same station number is used for more than one GT units.

Check the station number setting of the connected GT units.

4. Another GT is reading a SD card.

The indication disappears when reading the SD card has completed.

The memory for saving screen data may be damaged. Please contact us.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

5.3.3 When Connected to a FP Series PLC

Error codes which are sent from the PLC are listed in the table below. For details, refer to the table of

MEWTOCOL-COM communication errors in PLC user’s manuals.

For GT01, GT11 and GT21

Code No.

ER21

ER22

ER40

ER41

ER42

ER53

Content

Data error

A data error occurred during communication.

Overrun error

The PLC isn’t receiving data.

BCC error

A data error occurred during communication.

Format error

The PLC has been sent a command that doesn’t match the protocol.

NOT support error

The GT has sent a non-supported command to the

PLC.

BUSY error

The PLC is currently processing another command.

Cause and solution

1) There is an error in the communication condition settings. Check the PLC and GT baud rate and transfer format.

2) There is a temporary error due to noise, etc. Re-supply power to the PLC and GT.

The CPU unit’s reception buffer is overflowing.

There could be an error in the PLC.

Re-supply power to the PLC and GT.

1) There is a temporary error due to noise, etc.

Re-supply power to the PLC and GT.

2) There is an error in the CPU unit. Re-supply power to the PLC and GT.

1) There is a temporary error due to noise, etc.

Re-supply power to the PLC and GT.

2) There is an error in the CPU unit. Re-supply power to the PLC and GT.

1) There is a temporary error due to noise, etc.

Re-supply power to the PLC and GT.

2) There is an error in the CPU unit. Re-supply power to the PLC and GT.

A large amount of data is being communicated with another

RS232C port on the PLC.

Wait until the error is gone.

ER60

ER61

Parameter errror The specified parameter does not exist, or it cannot be used.

Data run error

There is an error in the register or relay number.

A register or relay number which doesn’t exist in the PLC was specified during screen creation using GTWIN.

Correct the output device being used with the part, or the transfer of clock data to an external device.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

For GT02, GT02L, GT05, GT12, GT32 and GT32-E

Code No.

ER0021

ER0022

ER0040

ER0041

ER0042

ER0053

Content

Data error

A data error occurred during communication.

Overrun error

The PLC isn’t receiving data.

BCC error

A data error occurred during communication.

Format error

The PLC has been sent a command that doesn’t match the protocol.

NOT support error

The GT has sent a non-supported command to the

PLC.

BUSY error

The PLC is currently processing another command.

Cause and solution

1) There is an error in the communication condition settings. Check the PLC and GT baud rate and transfer format.

2) There is a temporary error due to noise, etc. Re-supply power to the PLC and GT.

The CPU unit’s reception buffer is overflowing.

There could be an error in the PLC.

Re-supply power to the PLC and GT.

1) There is a temporary error due to noise, etc.

Re-supply power to the PLC and GT.

2) There is an error in the CPU unit. Re-supply power to the PLC and GT.

1) There is a temporary error due to noise, etc.

Re-supply power to the PLC and GT.

2) There is an error in the CPU unit. Re-supply power to the PLC and GT.

1) There is a temporary error due to noise, etc.

Re-supply power to the PLC and GT.

2) There is an error in the CPU unit. Re-supply power to the PLC and GT.

A large amount of data is being communicated with another

RS232C port on the PLC.

Wait until the error is gone.

ER0060 Parameter errror The specified parameter does not exist, or it cannot be used.

ER0061

Data run error

There is an error in the register or relay number.

A register or relay number which doesn’t exist in the PLC was specified during screen creation using GTWIN.

Correct the output device being used with the part, or the transfer of clock data to an external device.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

5.3.4 When Connected to a PLC (FX Series) Made by Mitsubishi Electric

Corporation

For GT01, GT11 and GT21

Code No.

ERFF

Content

Time up error

There is no response from the PLC.

Cause and solution

1) PLC connection cable is disconnected. Check the wiring of the connection cable and check for disconnection.

2) It is a temporary error caused by noise, etc. Turn on the power supplies for PLC or GT again.

ER10

ER12

ER61

Data error

A data error occurred during communication

Overrun error

The GT cannot receive data.

PLC error

A NAK error has been returned from the PLC.

Check for errors in the communication conditions settings.

PLC runaway might be the problem.

Verify the PLC settings.

For GT02, GT02L, GT05, GT12, GT32 and GT32-E

Code No.

ERFFFE

Content

NAK error

A NAK error has been returned from the PLC.

Cause and solution

Verify the PLC settings.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

5.3.5 When Connected to a PLC Made by Omron Corporation

For GT01, GT11 and GT21

Code No. Content Cause and solution

ER00

Time up error

There is no response from the PLC.

1) PLC connection cable is disconnected. Check the wiring of the connection cable and check for disconnection.

2) It is a temporary error caused by noise, etc. Turn on the power supplies for PLC or GT again.

ER01

ER10

ER12

Cannot be executed due to operation mode.

(The PLC received the command that cannot be executed in the operation mode.)

Data error

A data error occurred during communication

Overrun error

The GT cannot receive data.

Change the mode of the PLC from the operation mode to the monitor mode.

Check for errors in the communication conditions settings.

PLC runaway might be the problem.

ER15

Numerical data error

Designated read/write area is wrong.

Verify whether or not the reference device used with the basic communication area and each part is a readable and writable area.

• Error codes other than these are based on Omron PLC error codes.

• Be sure to used the PLC in monitor mode. Otherwise, communication will not work properly.

For GT02, GT02L, GT05, GT12, GT32 and GT32-E

Code No. Content Cause and solution

ER0001

ER0010

ER0012

Cannot be executed due to operation mode.

(The PLC received the command that cannot be executed in the operation mode.)

Data error

A data error occurred during communication

Overrun error

The GT cannot receive data.

Change the mode of the PLC from the operation mode to the monitor mode.

Check for errors in the communication conditions settings.

PLC runaway might be the problem.

ER0015

Numerical data error

Designated read/write

Verify whether or not the reference device used with the basic communication area and each part is a readable and writable area is wrong. area.

• Error codes other than these are based on Omron PLC error codes.

• Be sure to used the PLC in monitor mode. Otherwise, communication will not work properly.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

5.3.6 When Connected to Modbus

For GT01, GT11 and GT21

Code No.

ERFF

Content

Time up error

There is no response from the PLC.

Cause and solution

1) PLC connection cable is disconnected. Check the wiring of the connection cable and check for disconnection.

2) It is a temporary error caused by noise, etc. Turn on the power supplies for PLC or GT again.

ERFE

Response error

There is an abnormal response returned from the external device.

Check the data to be returned from the external device.

For GT02, GT02L, GT05, GT12, GT32 and GT32-E

Code No.

**0001

Content

Time up error

There is no response from the PLC.

Cause and solution

1) PLC connection cable is disconnected. Check the wiring of the connection cable and check for disconnection.

2) It is a temporary error caused by noise, etc. Turn on the power supplies for PLC or GT again.

**ERFE

Response error

There is an abnormal response returned from the external device.

Check the data to be returned from the external device.

5.3.7 When Connected to a PLC Made by Toshiba Machine Co., Ltd.

For GT02, GT02L, GT05, GT12, GT32 and GT32-E

Code No. Content

ERFFFE Parameter errror

Cause and solution

The specified parameter does not exist, or it cannot be used.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

5.3.8 When Performing General-purpose Serial Communication

For GT01, GT11 and GT21

Error code

ER00

ER01

ER02

ER03

ER04

ER05

ER06

ER07

Error name

BCC error

Format error

NOT supported error

Address error

Receive buffer overflow

Requested overflow

Data error

Data write inhibit error

Measures

The value of BCC may be incorrect. Check if there is no calculation mistake.

A command format may be incorrect. Check if it is correct.

A command used is not supported with the version of the

GT. Upgrade the version of the GT, or use another command.

The address specified does not exist in the GT. Check the address of the transmitted command.

The sent command exceeds the receivable number of bytes. Check the number of bytes of the sent command.

The sent readout command exceeds the number of bytes that can send back. Check the number of the read words.

The communication condition for the GT may be unmatched with the condition for a destination device.

Check the communication conditions.

A command for the address that writingn is not available was sent. Check the address of the sent command.

For GT02, GT02, GT05, GT12, GT32 and GT32-E

Error code

**0000

**0001

**0002

**0003

**0004

**0005

**0006

**0007

Error name

BCC error

Format error

NOT supported error

Address error

Receive buffer overflow

Requested overflow

Data error

Data write inhibit error

Measures

The value of BCC may be incorrect. Check if there is no calculation mistake.

A command format may be incorrect. Check if it is correct.

A command used is not supported with the version of the

GT. Upgrade the version of the GT, or use another command.

The address specified does not exist in the GT. Check the address of the transmitted command.

The sent command exceeds the receivable number of bytes. Check the number of bytes of the sent command.

The sent readout command exceeds the number of bytes that can send back. Check the number of the read words.

The communication condition for the GT may be unmatched with the condition for a destination device.

Check the communication conditions.

A command for the address that writingn is not available was sent. Check the address of the sent command.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Chapter 6

Specifications

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.1 GT01

6.1.1 General Specifications

Specifications

Item

AIGT0030B

AIGT0030H

AIGT0130B

AIGT0130H

AIGT0032B

AIGT0032H

AIGT0132B

AIGT0132H

AIGT0030B1

AIGT0030H1

AIGT0130B1

AIGT0130H1

AIGT0032B1

AIGT0032H1

AIGT0132B1

AIGT0132H1

AIGT0230B AIGT0232B AIGT0230B1 AIGT0232B1

AIGT0230H AIGT0232H AIGT0230H1 AIGT0232H1

Rated voltage

Operating voltage range

Power consumption

Ambient humidity

Storage temperature -20 to +60 °C

Storage humidity

Breakdown voltage

24 V DC

21.6 to 26.4 V DC

2 W or less (80 mA or less)

Ambient temperature 0 to +50 °C

5 V DC

4.5 to 5.5 V DC

1W or less

(200 mA or less)

Note1)

20 to 85% RH (at 25 °C, non-condensing)

10 to 85% RH (at 25 °C, non-condensing)

Between [power supply terminals] and [case]

500 V AC for 1 minute, Cutoff current 10mA (at default setting)

1.1 W or less

(220 mA or less)

Note1)

Vibration resistance

100 MΩ or more, 500 V DC, measured with megohmmeter (at default setting)

10 to 55 Hz (1-minute cycle)

Amplitude: 0.75 mm, 10 min on 3 axes

98 m/s

2 or more, 4 times on 3 axes Shock resistance

EMC Directive applicable

EMC Directive: EN61000-6-2, EN61000-6-4 Not applicable

Noise immunity

Protective construction

1000 V [P-P] or more, Pulse width 50 ns, 1µs between power supply terminals

(based on in-house measurements)

Note2)

IP65 (Initial value, evaluated by us)

Dustproof and drip-proof from front panel only (packing used on panel contact surface)

Note3)

Approx. 160 g Weight

Note1) When supplying the power from the TOOL port of a PLC (CPU unit), comfirm the PLC restrictions such as the power supply capacity before use.

Note2) When using our exclusive cable (24 V DC) and the ferrite core attached to the cable (5 V DC).

Note3) When reattaching, replace waterproof packing.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.1.2 Performance Specifications (GT01)

Item

AIGT0030B1

AIGT0030H1

AIGT0030B

AIGT0030H

AIGT0032B1

AIGT0032H1

AIGT0032B

Specifications

AIGT0130B1

AIGT0130H1

AIGT0130B

AIGT0130H

AIGT0132B1

AIGT0132H1

AIGT0132B

AIGT0230B1

AIGT0230H1

AIGT0230B

AIGT0230H

AIGT0232B1

AIGT0232H1

AIGT0232B

Display

AIGT0032H

AIGT0132H

AIGT0232H

Display device

Resolution

STN monochrome LCD

128 (W) x 64 (H) dots

Displayable area 70.38 (W) x 35.18 (H) mm

Backlight

Backlight brightness

Contrast

3-color LED backlight

(green, orange, red)

1-color LED backlight

(white)

3-color LED bakclight

(white, pink, red)

Backlight brightness can be adjusted on the menu screen or GTWIN configuration settings.

(There are some minor variations in the backlight brightness.)

Can be adjusted on the menu screen or GTWIN configuration settings.

Touch switch Analog touch switch (resistive film type)

Touch switches

Touch switch operation

0.5 N or less

Life 1 million times or more (at 25 °C)

Note1)

Memory F-ROM Screen data (base, keyboard), Flow display data: 384 kbytes

Note2)

Note1) The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.1.3 Function Specifications (GT01)

Item Specifications

Displayable fonts

Character types

Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16)

(Double or quadruple in height and width)

True Type (GTWIN): 10 to 64 dots

Windows (R): 10 to 64 dots

English, Japanese, Korean, German, French, Italian, Spanish, Simplified

Chinese, Traditional Chinese characters and Turkish can be displayed.

160 screens

Note1)

Number of registerable screens

Registerable screen number

Graphics

Base screen: No. 0 to 3FF

Keyboard screen: No. 0 to 7

Straight lines, continuous straight lines, squares, circles, ovals, arcs, elliptic arcs, fan shapes, elliptic fan shapes, beveled squares

Types of parts

Through function

Switch

Function switch

Lamp

Message

Data

Bar graph

Note2)

Clock

Line graph

Keyboard

Custom(message, lamp, switch)

Main functions

Note3)

Recipe

Flow display

Write device

Multi language exchange

Connecting a computer to TOOL port and our PLC to COM port enables the communication between the PLC and the computer.

Copy function *5

GTWIN ver.

The screen data can be copied by connecting the main units with a cable.

Ver. 2.30 or later

Note1) Maximum allowable number varies depending on registered contents.

Note2) A clock part can be indicated by referring to external clock data. Clock function is not equipped in

GT01.

Note3) It depends on the version of GT.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.1.4 Interface Specifications (GT01)

Interface for connecting PLC/External devices

- COM port

Specifications

AIGT0032B1 AIGT0032B

AIGT0030B1/AIGT0030H1

AIGT0032H1 AIGT0032H

AIGT0030B/AIGT0030H

AIGT0132B1 AIGT0132B

Item AIGT0130B1/AIGT0130H1

AIGT0132H1 AIGT0132H

AIGT0130B/AIGT0130H

AIGT0232B1 AIGT0232B

AIGT0230B1/AIGT0230H1

AIGT0232H1 AIGT0232H

AIGT0230B/AIG0230H

5 VDC 24 VDC

Communication standard

Communication condition with external devices

Parity

Stop bit (bit)

Conforms to RS232C

(Non insulation type)

None, Odd, Even

1

Conforms to RS422

(Non insulation type)

Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps

Data length (bit) 7, 8

Transmission distance

(Total length)

Max. 15 m

(Baud rate: 19,200 bit/s)

Max. 30 m

(Baud rate:

115,200 bit/s)

Max. 500 m

(Baud rate:

115,200 bit/s)

- MEWTOCOL (Protocol for PANASONIC PLC: FP series)

Protocol

Connector

- General-purpose serial (PANASONIC dedicated protocol)

- Other companies’ PLC protocols (For the details, refer to the latest GTWIN HELP.)

Connector terminal base (8-pin)

Note1) 2) 3)

Note1) The (+) and (-) terminals are the power supply terminals for driving the main unit.

Note2) Regarding power supply voltage, please pay due consideration to the cable length so that the applied voltage is within the operation voltage range.

Note3) Wen supplying power from a power supply separate from the PLC, make sure the power cable is no longer than 10 m. (5 V DC type only)

Interface for transferring screen data

- TOOL port

Item Specifications

Communication standard Conforms to RS232C (Non insulation type)

Baud rate (bit/s) 9600, 19200, 115200, 230400 bps

Note1) 2)

Conditions for communications with GTWIN

Protocol

Connector

Data length (bit) 8

Parity

Stop bit (bit)

None, Odd, Even

1

GT dedicated protocol

Mini-DIN (5-pin)

Note1) The baud rate of 230400 bps is available when the USB/RS232C conversion cable is used.

Note2) When the baud rate is set to 230400 bps, the connection using the GTWIN automatic communication setting function is not possible. Set the GTWIN communication setting to 230400 bps, and then transfer data.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.2 GT02

6.2.1 General Specifications (GT02)

Specifications

Item

24 V DC type 5 V DC

Rated voltage

Operating voltage range

Power consumption

Ambient temperature

Ambient humidity

Storage temperature

Storage humidity

Breakdown voltage

Insulation resistance

Vibration resistance

Shock resistance

EC Directive applicable

Noise immunity

Protective construction

24 V DC

21.6 to 26.4 V DC

1.9 W or less (80 mA or less)

5 V DC

4.5 to 5.5 V DC

1W or less

(200 mA or less)

Note1)

0 to +50 °C

20 to 85% RH (at 25 °C, non-condensing)

-20 to +60 °C

10 to 85% RH (at 25 °C, non-condensing)

Between [power supply terminals] and [case]

500 V AC for 1 minute, Cutoff current 10mA (at default setting)

Between [power supply terminals] and [case]

100 MΩ or more, 500 V DC, measured with megohmmeter (at default setting)

5 to 8.4 Hz half amplitude 3.5 mm,

8.4 to 150 Hz acceleration 9.8 m/s

147 m/s

2

2

,

10 sweeps each in X, Y and Z directions (1 octave/min)

, 3 times on 3 axes

EN61131-2 (EMC Directive)

1000 V [P-P] or more, Pulse width 50 ns, 1µs between power supply terminals (based on in-house measurements)

IP67 (Initial value, evaluated by us)

Dustproof and drip-proof from front panel only (packing used on panel contact surface)

Approx. 170 g

Note3)

Note2)

Weight

Note1) When supplying the power from the TOOL port of a PLC (CPU unit), comfirm the PLC restrictions such as the power supply capacity before use.

Note2) When using our exclusive cable.

Note3) When reattaching, replace waterproof packing.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.2.2 Performance Specifications (GT02)

Display

Specifications

Item

GT02M GT02G

Display device STN monochrome LCD

Resolution

Displayable area

240 (W) x 96 (H) dots

88.5 (W) x 35.4 (H) mm

Backlight

Backlight brightness

Contrast

3-color LED bakclight (white, pink, red)

3-color LED backlight (green, orange, red)

Backlight brightness can be adjusted on the menu screen or GTWIN configuration settings.

(There are some minor variations in the backlight brightness.)

Contrast can be adjusted on the menu screen.

Touch switch

SRAM

Note2)

Analog touch switch (resistive film type)

Touch switches

Memory

Battery

Note3)

Touch switch operation

Life

F-ROM

Backup

0.8 N or less

1 million times or more (at 25 °C)

Note1)

Screen data (base, keyboard, login), Flow display data, FP monitor screen data: 2048 kbytes

Note2)

Recipe data: 64 k bytes

Write device data: 64 kbytes

Alarm history + Line graph sampling (27.5 kbytes)

Logging data of Logging function (64 kbytes)

Hold GT Device (2048 + 255 words)

Hold PLC Device (24 words)

Built-in clock data

Alarm history data

Line graph sampling data

Logging data of Logging function

Internal device hold data

Hold PLC Device data

Approx. 5 years (at 25 °C) Life

Note1) The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.

Note2) It is available for GT02M2/GT02G2 only. A battery is necessary for SRAM backup.

The unused part of 27 kbytes for Alarm history and line graph sampling can be used for the logging function.

Note3) It is available for GT02M2/GT02G2 only. Please purchase a battery separately.

The battery life is the value when no power at all is supplied. The actual lifetime may be shorter according to the condition of use.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.2.3 Function Specifications (GT02)

Item Specifications

Displayable fonts

Character types

Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16)

(Double, quadruple or octuple in height and width)

True Type (GTWIN): 10 to 96 dots

Windows (R): 10 to 96 dots

English, Japanese, Korean, German, French, Italian, Spanish, Simplified

Chinese, Traditional Chinese characters and Turkish can be displayed.

250 screens

Note1)

Number of registerable screens

Registerable screen number

Graphics

Base screen: No. 0 to 3FF

Keyboard screen: No. 0 to 7

Login screen: No. 0 to F

Straight lines, continuous straight lines, squares, circles, ovals, arcs, elliptic arcs, fan shapes, elliptic fan shapes, beveled squares

Types of parts Switch

Function switch

Lamp

Message

Data

Bar graph

Note2) 3)

Clock

Line graph

Alarm list

Keyboard

Custom(message, lamp, switch)

Main functions

Note4)

Recipe

SD recipe

Note5)

,

Flow display

Write device

Multi language exchange

Operation security

GT link

PLC multiple connection

Data logging

Note5)

FP monitor

Through function

Copy function

Note5)

Connecting a computer to USB port and our PLC to COM port enables the communication between the PLC and the computer.

Screen data can be copied with a SD memory card.

GTWIN ver. Ver. 2.A0 or later

Note1) Maximum allowable number varies depending on registered contents.

Note2) External clock data can be referred and displayed.

Note3) Accuracy of the GT internal clock is ±180 seconds per month.

Note4) It depends on the version of GT.

Note5) It is available for GT02M2 and GT02G2 only.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.2.4 Interface Specifications (GT02)

Interface for connecting PLC/External devices

- COM port

Specifications

Item

RS232C type RS422/RS485 type

Communication standard

Communication condition with external devices

Baud rate (bit/s)

Data length (bit)

Parity

Stop bit (bit)

Transmission distance

(Total length)

Terminal resistance value

Protocol

Conforms to RS232C

(Non insulation type)

Conforms to RS422

(Non insulation type)

9600, 19200, 38400, 57600, 115200 bps

7, 8

None, Odd, Even

1

Max. 15 m

(Baud rate: 19200 bit/s)

Max. 500 m

(Baud rate: 115200 bit/s)

120 Ω

-

MEWTOCOL (Protocol for PANASONIC PLC: FP series)

-

General-purpose serial (PANASONIC dedicated protocol)

-

Protocol for other companies' PLCs

(For the details, refer to the latest GTWIN HELP.)

Connector terminal base (8-pin)

Note1) 2) 3)

Connector

Note1) It is internally isolated from the input power supply side (between +24V and 0V).

Note2) The (+) and (-) terminals are the power supply terminals for driving the main unit.

Note3) Regarding power supply voltage, please pay due consideration to the cable length so that the applied voltage is within the operation voltage range.

Interface for transferring screen data

- TOOL port

Item Specifications

Communication standard

Connector shape

Note1)

USB1.1

USB MiniB type 5pin (Male)

Trasmission distance Max. 5 m

No. of connected unit with PC 1 unit

Note1) Take care of handling of the connector not to add an excessive static electricy on the metal part of the connector.

SD memory card slot (For GT02M2/GT02G2 only)

Item

Support media

Supported format standard Conforms to SD standard

Specifications

SD memory card, SDHC memory card

Note2)

Note1)

Note1) The manufacturer name that the operation check has done: Panasonic Corporation

Note2) Please format with a format software for SD memory cards.

Note3) The SD access lamp turns on while acccessing the SD memory card.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.3 GT02L

6.3.1 General Specifications (GT02L)

Item Specifications

Rated voltage

Operating voltage range

Power consumption

Ambient temperature

Ambient humidity

Storage temperature

Storage humidity

Breakdown voltage

Insulation resistance

Vibration resistance

Shock resistance

EC Directive applicable

Noise immunity

Protective construction

5 V DC

4.5 to 5.5 V DC

1W or less (200 mA or less)

Note1)

0 to +50 °C

20 to 85% RH (at 25 °C, non-condensing)

-20 to +60 °C

10 to 85% RH (at 25 °C, non-condensing)

Between [power supply terminals] and [case]

500 V AC for 1 minute, Cutoff current 10mA (at default setting)

Between [power supply terminals] and [case]

100 MΩ or more, 500 V DC, measured with megohmmeter (at default setting)

5 to 8.4 Hz half amplitude 3.5 mm,

8.4 to 150 Hz acceleration 9.8 m/s

2

,

10 sweeps each in X, Y and Z directions (1 octave/min)

147 m/s

2

, 3 times on 3 axes

EN61131-2 (EMC Directive)

1000 V [P-P] or more, Pulse width 50 ns, 1µs between power supply terminals (based on in-house measurements)

IP65 (Initial value, evaluated by us)

Dustproof and drip-proof from front panel only (packing used on panel contact surface)

Note3)

Approx. 150 g

Note2)

Weight

Note1) When supplying the power from the TOOL port of a PLC (CPU unit), comfirm the PLC restrictions such as the power supply capacity before use.

Note2) When using our exclusive cable.

Note3) When reattaching, replace waterproof packing.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.3.2 Performance Specifications (GT02L)

Display

Item Specifications

Display device STN monochrome LCD

Resolution 160 (W) x 64 (H) dots

Displayable area

Backlight

88.0 (W) x 35.2 (H) mm

Backlight brightness

Contrast

LED bakclight (white)

Backlight brightness can be adjusted on the menu screen or GTWIN configuration settings.

(There are some minor variations in the backlight brightness.)

Contrast can be adjusted on the menu screen.

Touch switch Analog touch switch (resistive film type)

Touch switches

Touch switch operation

Life

Memory F-ROM

0.8 N or less

1 million times or more (at 25 °C)

Note1)

Screen data (base, keyboard, login), Flow display data, FP monitor screen data: 640 kbytes

Recipe data: 64 k bytes

Write device data: 64 kbytes

Note1) The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.3.3 Function Specifications (GT02L)

Item Specifications

Displayable fonts

Character types

Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16)

(Double, quadruple or octuple in height and width)

True Type (GTWIN): 10 to 64 dots

Windows (R): 10 to 64 dots

English, Japanese, Korean, German, French, Italian, Spanish, Simplified

Chinese, Traditional Chinese characters and Turkish can be displayed.

80 screens

Note1)

Number of registerable screens

Registerable screen number

Graphics

Base screen: No. 0 to 3FF

Keyboard screen: No. 0 to 7

Login screen: No. 0 to F

Straight lines, continuous straight lines, squares, circles, ovals, arcs, elliptic arcs, fan shapes, elliptic fan shapes, beveled squares

Types of parts Switch

Function switch

Lamp

Message

Data

Bar graph

Note2)

Clock

Line graph

Alarm list

Keyboard

Custom(message, lamp, switch)

Main functions

Note3)

Recipe

Flow display

Write device

Multi language exchange

Operation security

GT link

PLC multiple connection

FP monitor

Through function

GTWIN ver.

Connecting a computer to USB port and our PLC to COM port enables the communication between the PLC and the computer.

Ver. 2.B0 or later

Note1) Maximum allowable number varies depending on registered contents.

Note2) External clock data can be referred and displayed.

Note3) It depends on the version of GT.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.3.4 Interface Specifications (GT02L)

Interface for connecting PLC/External devices

- COM port

Specifications

Item

RS232C type RS422/RS485 type

Communication standard Conforms to RS232C

(Non insulation type)

9600, 19200, 38400, 57600, 115200 bps

7, 8

Conforms to RS422

(Non insulation type)

Communication condition with external devices

Protocol

Connector

Baud rate (bit/s)

Data length (bit)

Parity

Stop bit (bit)

Transmission distance

(Total length)

Terminal resistance value

None, Odd, Even

1

Max. 15 m

(Baud rate: 19200 bit/s)

Max. 500 m

(Baud rate: 115200 bit/s)

120 Ω

-

MEWTOCOL (Protocol for PANASONIC PLC: FP series)

-

General-purpose serial (PANASONIC dedicated protocol)

-

Protocol for other companies' PLCs

(For the details, refer to the latest GTWIN HELP.)

Connector terminal base (8-pin)

Note1) 2) 3)

Note1) The (+) and (-) terminals are the power supply terminals for driving the main unit.

Note2) Regarding power supply voltage, please pay due consideration to the cable length so that the applied voltage is within the operation voltage range.

Note3) When tightening the terminal block requiers a flat-blade screwdriver with a blade size of 0.4 x 2.5 or special screwdriver (part No.: AFP0806). Set the tightening torque between 0.22 Nm to 0.25

Nm.

Applicable wire

Size

AWG#28 to 16

Nominal cross-sectional area

0.08 to 1.25mm

2

Interface for transferring screen data

- USB port

Item

Communication standard

Connector shape

Note1)

Trasmission distance

USB1.1

USB MiniB type 5pin (Male)

Max. 5 m

Specifications

No. of connected unit with PC 1 unit

Note1) Take care of handling of the connector not to add an excessive static electricy on the metal part of the connector.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.4 GT05

6.4.1 General Specifications

Specifications

Item

GT05S GT05M/GT05G

Rated voltage 24 V DC

Operating voltage range 21.6 to 26.4 V DC

Power consumption

Insulation method of power supply part

Ambient temperature

3.6 W or less (150 mA or less)

Transformer insulation

Ambient humidity

Storage temperature

Storage humidity

2.4 W or less (100 mA or less)

0 to +50 °C

20 to 85% RH (at 25 °C, non-condensing)

-20 to +60 °C

10 to 85% RH (at 25 °C, non-condensing)

Breakdown voltage

Insulation resistance

Note1)

Note1)

Between [power supply terminals] and [case]

Between [power supply terminals] and [case]

Vibration resistance

100 MΩ or more, 500 V DC, measured with megohmmeter (at default setting)

10 to 55 Hz (1-minute cycle)

Amplitude: 0.75 mm, 10 min on 3 axes

Shock resistance 98 m/s

2 or more, 4 times on 3 axes

EC Directive applicable EN61131-2 (EMC Directive)

Noise immunity

Protective construction

1000 V [P-P] or more, Pulse width 50 ns, 1µs between power supply terminals (based on in-house measurements)

Note2)

IP65 (Initial value, evaluated by us)

Dustproof and drip-proof from front panel only (packing used on panel contact surface)

Note3)

Weight Approx. 230 g

Note1) Not isolated between the USB port, COM. port and the internal digital circuit.

Note2) When using our exclusive cable.

Note3) When reattaching, replace waterproof packing.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.4.2 Performance Specifications (GT05)

Specifications

Item

GT05S GT05M GT05G

Display

Touch switches

Memory

Battery

Note3)

Display device 4096-color STN color LCD

Resolution 320 (W) x 240 (H) dots

Displayable area 71.02 (W) x 53.26 (H) mm

Backlight

Backlight brightness

Contrast

Touch switch

Touch switch operation

Life

1-color LED backlight (white)

Backlight brightness can be adjusted on the menu screen or GTWIN configuration settings.

(There are some minor variations in the backlight brightness.)

Contrast can be adjusted on the menu screen.

Analog touch switch (resistive film type)

0.8 N or less

1 million times or more (at 25 °C)

STN monochrome LCD

3-color LED bakclight

(white, pink, red)

Note1)

3-color LED backlight (green, orange, red)

F-ROM

SRAM

Note2)

Backup

Screen data (base, keyboard, login), Flow display data, FP monitor screen data: 12288 kbytes

Recipe data: 64 k bytes

Write device data: 64 kbytes

Screen data (base, keyboard, login),

Flow display data, FP monitor screen data: 2048 kbytes

Alarm history + Line graph sampling (27.5 kbytes)

Logging data of Logging function (64 kbytes)

Hold GT Device (2048 + 255 words)

Hold PLC Device (24 words)

Built-in clock data

Alarm history data

Line graph sampling data

Logging data of Logging function

Internal device hold data

Hold PLC Device data

Life Approx. 3 years (at 25 °C) Approx. 5 years (at 25 °C)

Note1) The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.

Note2) A battery is necessary for SRAM backup.

The unused part of 27 kbytes for Alarm history and line graph sampling can be used for the logging function.

Note3) Please purchase a battery separately.

The battery life is the value when no power at all is supplied. The actual lifetime may be shorter according to the condition of use.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.4.3 Function Specifications (GT05)

Specifications

Item

GT05S GT05M/GT05G

Displayable fonts

Character types

Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16)

(Double, quadruple or octuple in height and width)

True Type (GTWIN): 10 to 240 dots

Windows (R): 10 to 240 dots

English, Japanese, Korean, German, French, Italian, Spanish, Simplified

Chinese, Traditional Chinese characters and Turkish can be displayed.

Approx. 180 screens

Note1)

Approx. 240 screens

Note1)

Number of registerable screens

Registerable screen number

Graphics

Base screen: No. 0 to 3FF

Keyboard screen: No. 0 to 7

Login screen: No. 0 to F

Straight lines, continuous straight lines, squares, circles, ovals, arcs, elliptic arcs, fan shapes, elliptic fan shapes, beveled squares

Types of parts Switch

Function switch

Lamp

Message

Data

Bar graph

Note2) 3)

Clock

Line graph

Alarm list

Keyboard

Custom(message, lamp, switch)

Main functions

Note4)

Recipe

SD recipe

Through function

Flow display

Write device

Multi language exchange

Operation security

GT link

PLC multiple connection

Data logging

FP monitor

Connecting a computer to USB port and our PLC to COM port enables the communication between the PLC and the computer.

Copy function

GTWIN ver.

Screen data can be copied with a SD memory card.

Ver. 2.90 or later

Note1) Maximum allowable number varies depending on registered contents.

Note2) External clock data can be referred and displayed.

Note3) Accuracy of the GT internal clock is ±180 seconds per month.

Note4) It depends on the version of GT.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.4.4 Interface Specifications (GT05)

Interface for connecting PLC/External devices

- COM port

Specifications

Item

AIG05MQ02D/AIG05MQ03D

AIG05GQ02D/AIG05GQ03D

AIG05MQ04D/AIG05MQ05D

AIG05GQ04D/AIG05GQ05D

AIG05SQ02D/AIG05SQ03D AIG05SQ04D/AIG05SQ05D

Communication standard Conforms to RS232C (Non insulation type)

Note1)

Conforms to RS422 (Non insulation type)

Note1)

Communication condition with external devices

Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps

Data length (bit) 7, 8

Parity

Stop bit (bit)

None, Odd, Even

1

Transmission distance

(Total length)

Protocol

Connector

Max. 15 m

(Baud rate: 19200 bit/s)

Max. 500 m

(Baud rate: 115200 bit/s)

-

-

MEWTOCOL (Protocol for PANASONIC PLC: FP series)

General-purpose serial (PANASONIC dedicated protocol)

-

Other companies' PLC protocols (For the details, refer to the latest

GTWIN HELP.)

Connector terminal base (8-pin)

Note2) 3)

Note1) It is internally isolated from the input power supply side (between +24V and 0V).

Note2) The (+) and (-) terminals are the power supply terminals for driving the main unit.

Note3) Regarding power supply voltage, please pay due consideration to the cable length so that the applied voltage is within the operation voltage range.

Interface for transferring screen data

- USB port

Item Specifications

Communication standard

Connector shape

Note1)

USB1.1

TYPE-B

Trasmission distance Max. 5 m

No. of connected unit with PC 1 unit

Note1) Take care of handling of the connector not to add an excessive static electricy on the metal part of the connector.

SD memory card slot

Item Specifications

Support media SD memory card, SDHC memory card

Supported format standard Conforms to SD standard

Note2)

Note1)

Note1) The manufacturer name that the operation check has done: Panasonic Corporation

Usable capacity of a SD memory card varies according to the version of GT firmware.

Note2) Please format with a format software for SD memory cards.

Note3) The SD access lamp turns on while acccessing the SD memory card.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.5 GT11

6.5.1 General Specifications (GT11)

Item Specifications

Rated voltage 24 V DC

Operating voltage range 21.6 to 26.4 V DC

Power consumption

Ambient temperature

Ambient humidity

Storage temperature

Storage humidity

2.4 W or less (100 mA or less)

Note1)

0 to +50 °C

Note2)

20 to 85% RH (at 25 °C, non-condensing)

Breakdown voltage

Insulation resistance

Vibration resistance

Shock resistance

-20 to +60 °C

10 to 85% RH (at 25 °C, non-condensing)

Between [power supply terminals] and [case]

500 V AC for 1 minute, Cutoff current 10mA (at default setting)

Between [power supply terminals] and [case]

100 MΩ or more, 500 V DC, measured with megohmmeter (at default setting)

10 to 55 Hz (1-minute cycle)

Amplitude: 0.75 mm,

10 min on 3 axes

98 m/s

2

or more,

4 times on 3 axes

EC Directive applicable EMC Directive: EN61000-6-2, EN61000-6-4

Noise immunity

1000 V [P-P] or more, Pulse width 50 ns, 1µs between power supply terminals (based on in-house measurements)

Note3)

Protective construction

IP65 (Initial value, evaluated by us)

Dustproof and drip-proof from front panel only (packing used on panel contact surface)

Note4)

Weight Approx. 230 g

Note1) When connecting the FP programmer II to the TOOL port, it is 150 mA or less.

Note2) When connecting the FP programmer II or C-NET adapter to the TOOL port, the usable range is

0 to +45 °C.

Note3) When using our exclusive cable.

Note4) When reattaching, replace waterproof packing.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.5.2 Performance Specifications (GT11)

Specifications

Item AIGT2030B/AIGT2030H AIGT2130B/AIGT2130H

AIGT2032B/AIGT2032H AIGT2132B/AIGT2132H

Display

Display device

Backlight

STN monochrome LCD

Resolution 240 (W) x 96 (H) dots

Displayable area 96.0 (W) x 35.4 (H) mm

3-color LED backlight

(green, orange, red)

Backlight brightness

Contrast

Touch switch

1-color LED backlight (white)

Can be set on the menu screen or GTWIN configuration settings.

(There are some minor variations in the backlight brightness.)

Can be adjusted on the menu screen or GTWIN configuration settings.

Analog touch switch (resistive film type)

Touch switches

Memory

Touch switch operation

Life

F-ROM

SRAM

Note2)

0.5 N or less

1 million times or more (at 25 °C)

Note1)

Screen data (base, keyboard), Flow display data: 1408 kbytes

Write device data: 64 kbytes

Alarm history + Line graph sampling (27.5 kbytes)

Hold GT Device (2048 + 255 words)

Hold PLC Device (24 words)

Battery

Note3)

Backup

Built-in clock data

Alarm history data

Line graph sampling data

Internal device hold data

Hold PLC Device data

Approx. 2 years (at 25 °C) Life

Note1) The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.

Note2) A battery is necessary for SRAM backup.

Note3) Please purchase a battery separately.

The battery life is the value when no power at all is supplied. The actual lifetime may be shorter according to the condition of use.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.5.3 Function Specifications (GT11)

Item Specifications

Displayable fonts

Character types

Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16)

(Double or quadruple in height and width)

True Type (GTWIN): 10 to 96 dots

Windows (R): 10 to 96 dots

English, Japanese, Korean, German, French, Italian, Spanish, Simplified

Chinese, Traditional Chinese characters and Turkish can be displayed.

250 screens

Note1)

Number of registerable screens

Registerable screen number

Graphics

Base screen: No. 0 to 3FF

Keyboard screen: No. 0 to 7

Straight lines, continuous straight lines, squares, circles, ovals, arcs, elliptic arcs, fan shapes, elliptic fan shapes, beveled squares

Types of parts Switch

Function switch

Lamp

Message

Data

Bar graph

Note2) 3)

Clock

Line graph

Alarm list

Alarm history

Keyboard

Custom(message, lamp, switch)

Main functions

Note4)

Recipe

Flow display

Through function

Write device

Multi language exchange

Connecting a computer to TOOL port and our PLC to COM port enables the communication between the PLC and the computer.

Copy function *5

GTWIN ver.

The screen data can be copied by connecting the main units with a cable.

Ver. 2.60 or later

Note1) Maximum allowable number varies depending on registered contents.

Note2) A clock part can be indicated by referring to external clock data.

Note3) Accuracy of the GT internal clock is ±100 seconds per month.

Note4) It depends on the version of GT.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.5.4 Interface Specifications (GT11)

Interface for connecting PLC/External devices

- COM port

Specifications

Item AIGT2030B/AIGT2030H AIGT2032B/AIGT2032H

AIGT2130B/AIGT2130H AIGT2132B/AIGT2132H

Communication standard Conforms to RS232C

(Non insulation type)

Communication condition with external devices

Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps

Data length (bit) 7, 8

Parity

Stop bit (bit)

None, Odd, Even

1

Transmission distance

(Total length)

Protocol

Max. 15 m

(Baud rate: 19200 bit/s)

Max. 500 m

(Baud rate: 115200 bit/s)

-

-

MEWTOCOL (Protocol for PANASONIC PLC: FP series)

General-purpose serial (PANASONIC dedicated protocol)

-

Other companies' PLC protocols (For the details, refer to the latest

GTWIN HELP.)

Connector terminal base (8-pin)

Note1) 2)

Connector

Note1) The (+) and (-) terminals are the power supply terminals for driving the main unit.

Note2) Regarding power supply voltage, please pay due consideration to the cable length so that the applied voltage is within the operation voltage range.

Interface for transferring screen data

Conforms to RS422

(Non insulation type)

- TOOL port

Item Specifications

Communication standard Conforms to RS232C (Non insulation type)

Baud rate (bit/s) 9600, 19200, 115200, 230400 bps

Note1) 2)

Conditions for communications with GTWIN

Data length (bit) 8

Parity

Stop bit (bit)

None, Odd, Even

1

GT dedicated protocol

Mini-DIN (5-pin)

Protocol

Connector

Note1) The baud rate of 230400 bps is available when the USB/RS232C conversion cable is used.

Note2) When the baud rate is set to 230400 bps, the connection using the GTWIN automatic communication setting function is not possible. Set the GTWIN communication setting to 230400 bps, and then transfer data.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.6 GT12

6.6.1 General Specifications (GT12)

Item Specifications

Rated voltage 24 V DC

Operating voltage range 21.6 to 26.4 V DC

Power consumption

Insulation method of power supply part

Ambient temperature

1.7 W or less (70 mA or less)

Transformer insulation

Note1)

Ambient humidity

Storage temperature

Storage humidity

Breakdown voltage

Vibration resistance

Note1)

Insulation resistance

Note1)

Protective construction

Weight

0 to +50 C

20 to 85% RH (at 25 C, non-condensing)

-20 to +60 C

10 to 85% RH (at 25 C, non-condensing)

Between [power supply terminals (+ and – terminals)] and [function earth terminal]

500 V AC for 1 minute, Cutoff current 10mA (in initial status)

Between [power supply terminals (+ and – terminals)] and [function earth terminal]

100 M or more, 500 V DC, measured with megohmmeter (in initial status)

5 to 9 Hz amplitude 3.5 mm,

9 to 150 Hz acceleration 9.8 m/s

2

,

10 sweeps each in X, Y and Z directions (1 octave/min)

Shock resistance 147 m/s

2

, 3 times on 3 axes

EC Directive applicable EMC Directive: EN61131-2

Noise immunity

1000 V [P-P] or more, Pulse width 50 ns, 1s between power supply terminals (based on in-house measurements)

Note2)

IP67 (Initial value, evaluated by us)

Dustproof and waterproof from front panel only (packing used on panel contact surface)

Note3)

Approx. 240 g

Note1) Not isolated between the USB port, COM. port and the internal digital circuit.

Note2) When using our exclusive cable.

Note3) When installing the unit again, replace the water-proof packing.

6-22

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.6.2 Performance Specifications (GT12)

Item Specifications

GT12M GT12G

Display

Display device STN monochrome LCD

Resolution

Displayable area

320 (W) x 120 (H) dots

108.78 (W) x 40.78 (H) mm

Gradation

Backlight

2 gradation/8 gradation (Selectable with GTWIN.)

3-color LED bakclight

(white, pink, red)

3-color LED backlight

(green, orange, red)

Touch switches

Backlight brightness

Contrast

Touch switch

Touch switch operation

Life

Backlight brightness can be adjusted on the menu screen or GTWIN configuration settings.

(There are some minor variations in the backlight brightness.)

Contrast can be adjusted on the menu screen.

Analog touch switch (resistive film type)

0.8 N or less

Memory

F-ROM

SRAM

Note2)

1 million times or more (at 25 °C)

Note1)

Screen data (base, keyboard, login), Flow display data, FP monitor screen data: 2048 kbytes

Recipe data: 64 k bytes

Write device data: 64 kbytes

Alarm history + Line graph sampling (27.5 kbytes)

Logging data of Logging function (64 kbytes)

Hold GT Device (2048 + 255 words)

Hold PLC Device (24 words)

Battery

Note3)

Backup

Built-in clock data

Alarm history data

Line graph sampling data

Logging data of Logging function

Internal device hold data

Hold PLC Device data

Life Approx. 5 years (at 25 °C)

Note1) The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.

Note2) A battery is necessary for SRAM backup.

The unused part of 27 kbytes for Alarm history and line graph sampling can be used for the logging function.

Note3) Please purchase a battery separately.

The battery life is the value when no power at all is supplied. The actual lifetime may be shorter according to the condition of use.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.6.3 Function Specifications (GT12)

Item Specifications

Displayable fonts

Character types

Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16)

(Double, quadruple or octuple in height and width)

True Type (GTWIN): 10 to 120 dots

Windows (R): 10 to 120 dots

English, Japanese, Korean, German, French, Italian, Spanish, Simplified

Chinese, Traditional Chinese characters and Turkish can be displayed.

2 gradation:250 screens 8 gradation:200screens

Note1)

Number of registerable screens

Registerable screen number

Graphics

Base screen: No. 0 to 3FF

Keyboard screen: No. 0 to 7

Login screen: No. 0 to F

Straight lines, continuous straight lines, squares, circles, ovals, arcs, elliptic arcs, fan shapes, elliptic fan shapes, beveled squares

Types of parts Switch

Function switch

Lamp

Message

Data

Bar graph

Clock

Note2) 3)

Line graph

Alarm list

Keyboard

Custom(message, lamp, switch)

Main functions

Note4)

Recipe

SD recipe

Note5)

Flow display

Write device

Multi language exchange

Operation security

GT link

PLC multiple connection

Data logging

Note5)

FP monitor

Through function

Copy function

Note5)

Connecting a computer to USB port and our PLC to COM port enables the communication between the PLC and the computer.

Screen data can be copied with a SD memory card.

GTWIN ver. Ver. 2.97 or later

Note1) Maximum allowable number varies depending on registered contents.

Note2) External clock data can be referred and displayed.

Note3) Accuracy of the GT internal clock is ±180 seconds per month.

Note4) It depends on the version of GT.

Note5) It is available for GT12M1 and GT12G1 only.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.6.4 Interface Specifications (GT12)

Interface for connecting PLC/External devices

- COM port

Specifications

Item

AIG12*Q12D

AIG12*Q13D

AIG12*Q14D

AIG12*Q15D

RS232C type RS422/RS485 type

Communication standard

Communication condition with external devices

Parity

Stop bit (bit)

Conforms to RS232C

(Non insulation type)

Note1)

None, Odd, Even

1

Conforms to RS422

(Non insulation type)

Note1)

Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps

Data length (bit) 7, 8

Transmission distance

(Total length)

Protocol

Connector

Max. 15 m

(Baud rate: 19200 bit/s)

Max. 500 m

(Baud rate: 115200 bit/s)

-

-

MEWTOCOL (Protocol for PANASONIC PLC: FP series)

General-purpose serial (PANASONIC dedicated protocol)

-

Other companies' PLC protocols (For the details, refer to the latest

GTWIN HELP.)

Connector terminal base (8-pin)

Note2) 3)

Note1) It is internally isolated from the input power supply side (between +24V and 0V).

Note2) The (+) and (-) terminals are the power supply terminals for driving the main unit.

Note3) Regarding power supply voltage, please pay due consideration to the cable length so that the applied voltage is within the operation voltage range.

Interface for transferring screen data

- USB port

Item Specifications

Communication standard

Connector shape

Note1)

Trasmission distance

USB1.1

USB MiniB type 5pin (Male)

Max. 5 m

No. of connected unit with PC 1 unit

Note1) Take care of handling of the connector not to add an excessive static electricy on the metal part of the connector.

SD memory card slot (For GT12M1/GT12G1 only)

Item

Support media

Supported format standard

Specifications

SD memory card , SDHC memory card

Note1)

Conforms to SD standard

Note2)

Note1) The manufacturer name that the operation check has done: Panasonic Corporation

Usable capacity of a SD memory card varies according to the version of GT firmware.

Note2) Please format with a format software for SD memory cards.

Note3) The SD access lamp turns on while acccessing the SD memory card.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.7 GT21

6.7.1 General Specifications (GT21)

Item Specifications

Rated voltage 24 V DC

Operating voltage range 21.6 to 26.4 V DC

Power consumption

Ambient temperature

4.8 W or less (200 mA or less)

0 to +50 °C

Note1)

Ambient humidity

Storage temperature

Storage humidity

20 to 85% RH (at 25 °C, non-condensing)

-20 to +60 °C

10 to 85% RH (at 25 °C, non-condensing)

Breakdown voltage

Insulation resistance

Vibration resistance

Shock resistance

Between [power supply terminals] and [case]

500 V AC for 1 minute, Cutoff current 10mA (at default setting)

Between [power supply terminals] and [case]

100 MΩ or more, 500 V DC, measured with megohmmeter (at default setting)

10 to 55 Hz (1-minute cycle)

Amplitude: 0.75 mm,

10 min on 3 axes

98 m/s

2

or more,

4 times on 3 axes

EC Directive applicable EMC Directive: EN61000-6-2, EN61000-6-4

Noise immunity

1000 V [P-P] or more, Pulse width 50 ns, 1µs between power supply terminals (based on in-house measurements)

Note2)

Protective construction

IP65 (Initial value, evaluated by us)

Dustproof and drip-proof from front panel only (packing used on panel contact surface)

Note3)

Approx. 230 g Weight

Note1) When it is installed in a horizontal orientation (installed to make the liquid crystal face be topside) or when the FP programmer II or C-NET adapter is connected to the TOOL port, the usable range is 0 to +45 °C.

Note2) When using our exclusive cable.

Note3) When reattaching, replace waterproof packing.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.7.2 Performance Specifications (GT21)

Item Specifications

Display

Display device

Resolution

Displayable area

Backlight

Backlight brightness

256-color STN color LCD

320 (W) x 240 (H) dots

98.0 (W) x 74.0 (H) mm

1-color LED backlight (white)

Can be set on the menu screen or GTWIN configuration settings.

(There are some minor variations in the backlight brightness.)

Contrast

Touch switch

Touch switch operation

Life

Can be adjusted on the menu screen or GTWIN configuration settings.

Analog touch switch (resistive film type)

Touch switches

Memory

Battery

Note3)

F-ROM

SRAM

Note2)

Backup

0.8 N or less

1 million times or more (at 25 °C)

Note1)

Screen data (base, keyboard), Flow display data: 6656 kbytes

Write device data: 64 kbytes

Alarm history + Line graph sampling (27.5 kbytes)

Hold GT Device (2048 + 255 words)

Hold PLC Device (24 words)

Built-in clock data

Alarm history data

Line graph sampling data

Internal device hold data

Hold PLC Device data

Approx. 2 years (at 25 °C) Life

Note1) The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.

Note2) A battery is necessary for SRAM backup.

Note3) Please purchase a battery separately.

The battery life is the value when no power at all is supplied. The actual lifetime may be shorter according to the condition of use.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.7.3 Function Specifications (GT21)

Item Specifications

Displayable fonts

Character types

Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16)

(Double or quadruple in height and width)

True Type (GTWIN): 10 to 240 dots

Windows (R): 10 to 240 dots

English, Japanese, Korean, German, French, Italian, Spanish, Simplified

Chinese, Traditional Chinese characters and Turkish can be displayed.

250 screens

Note1)

Number of registerable screens

Registerable screen number

Graphics

Base screen: No. 0 to 3FF

Keyboard screen: No. 0 to 7

Straight lines, continuous straight lines, squares, circles, ovals, arcs, elliptic arcs, fan shapes, elliptic fan shapes, beveled squares

Types of parts Switch

Function switch

Lamp

Message

Data

Bar graph

Note2) 3)

Clock

Line graph

Alarm list

Alarm history

Keyboard

Custom(message, lamp, switch)

Main functions

Note4)

Recipe

Flow display

Through function

Write device

Multi language exchange

Connecting a computer to TOOL port and our PLC to COM port enables the communication between the PLC and the computer.

Copy function *5

GTWIN ver.

The screen data can be copied by connecting the main units with a cable.

Ver. 2.70 or later

Note1) Maximum allowable number varies depending on registered contents.

Note2) A clock part can be indicated by referring to external clock data.

Note3) Accuracy of the GT internal clock is ±180 seconds per month.

Note4) It depends on the version of GT.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.7.4 Interface Specifications (GT21)

Interface for connecting PLC/External devices

- COM port

Specifications

Item

AIGT2230B/AIGT2230H AIGT2232B/AIGT2232H

Communication standard Conforms to RS232C

(Non insulation type)

Communication condition with external devices

Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps

Data length (bit) 7, 8

Parity

Stop bit (bit)

None, Odd, Even

1

Transmission distance

(Total length)

Protocol

Max. 15 m

(Baud rate: 19200 bit/s)

Max. 500 m

(Baud rate: 115200 bit/s)

-

-

MEWTOCOL (Protocol for PANASONIC PLC: FP series)

General-purpose serial (PANASONIC dedicated protocol)

-

Other companies' PLC protocols (For the details, refer to the latest

GTWIN HELP.)

Connector terminal base (8-pin)

Note1) 2)

Connector

Note1) The (+) and (-) terminals are the power supply terminals for driving the main unit.

Note2) Regarding power supply voltage, please pay due consideration to the cable length so that the applied voltage is within the operation voltage range.

Interface for transferring screen data

Conforms to RS422

(Non insulation type)

- TOOL port

Item Specifications

Communication standard Conforms to RS232C (Non insulation type)

Baud rate (bit/s) 9600, 19200, 115200, 230400 bps

Note1) 2)

Conditions for communications with GTWIN

Protocol

Connector

Data length (bit) 8

Parity

Stop bit (bit)

None, Odd, Even

1

GT dedicated protocol

Mini-DIN (5-pin)

Note1) The baud rate of 230400 bps is available when the USB/RS232C conversion cable is used.

Note2) When the baud rate is set to 230400 bps, the connection using the GTWIN automatic communication setting function is not possible. Set the GTWIN communication setting to 230400 bps, and then transfer data.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.8 GT32

6.8.1 General Specifications (GT32)

Specifications

Item

GT32M GT32T0

Rated voltage 24 V DC

Operating voltage range 21.6 to 26.4 V DC

Power consumption

Insulation method of power supply part

Ambient temperature

10 W or less (410 mA or less)

Transformer insulation

Ambient humidity

Storage temperature

Storage humidity

0 to +50 °C

Note1)

20 to 85% RH (at 25 °C, non-condensing)

-20 to +60 °C

10 to 85% RH (at 25 °C, non-condensing)

GT32T1

12 W or less (500 mA or less)

Breakdown voltage

Note2)

Insulation resistance

Vibration resistance

Shock resistance

EC Directive applicable EN61131-2 (EMC Directive)

Noise immunity

Between [power supply terminals] and [case]

100 MΩ or more, 500 V DC, measured with megohmmeter (at default setting)

10 to 55 Hz (1-minute cycle), Amplitude: 0.75 mm, 10 min on 3 axes

98 m/s

2

, 4 times on 3 axes

1000 V [P-P] or more, Pulse width 50 ns, 1µs between power supply terminals (based on in-house measurements)

Note3)

Protective construction

Weight

IP65 (Initial value, evaluated by us)

Dustproof and drip-proof from front panel only (packing used on panel contact surface)

Approx. 500 g

Note4)

Approx. 470 g Approx. 480 g

Note1) When it is installed in a horizontal orientation (installed to make the liquid crystal face be topside), the usable range is 0 to +40 °C.

Note2) Not isolated between the USB port, COM port, Ethernet port (GT32T1 only) and the internal digital circuit.

Note3) When using our exclusive cable.

Note4) When reattaching, replace waterproof packing.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.8.2 Performance Specifications (GT32)

Item Specifications

GT32M GT32T0 GT32T1

Display

Touch switches

Through function

Memory

Battery

Note3)

Display device

Resolution

Displayable area 113.2 (W) x 86.4 (H) mm

Backlight

LCD life

Contrast

Blue-white STN monochrome LCD

320 (W) x 240 (H) dots

4096-color TFT color LCD

110.8 (W) x 83.6 (H) mm

CFL backlight

75000 hours (at 25 C)

Note4)

Can be adjusted on the menu screen.

50000 hours (at 25 C)

None

Analog touch switch (resistive film type)

Note4)

Touch switch

Touch switch operation

Life

0.8 N or less

F-ROM

SRAM

Life

Note2)

Backup

1 million times or more (at 25 C)

Note1)

Connecting a computer to Ethernet port or USB port and our PLC to

COM port enables the communication between the PLC and the computer.

Note6)

Screen data (base, keyboard, login), Flow display data, FP monitor screen data: 2048 kbytes

Screen data (base, keyboard, login), Flow display data,

Sound function, FP monitor screen data: 12288 kbytes

Note5)

Recipe data: 64 k bytes

Write device data: 64 kbytes

Alarm history + Line graph sampling (27.5 kbytes)

Logging data of Logging function (64 kbytes)

Hold GT Device (2048 + 255 words)

Hold PLC Device (24 words)

Built-in clock data

Alarm history data

Line graph sampling data

Logging data of Logging function

Internal device hold data

Hold PLC Device data

Approx. 5 years (at 25 C) Approx. 3 years (at 25 C)

Note1) The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.

Note2) A battery is necessary for SRAM backup.

The unused part of 27 kbytes for Alarm history and line graph sampling can be used for the logging function.

Note3) Please purchase a battery separately.

The battery life is the value when no power at all is supplied. The actual lifetime may be shorter according to the condition of use.

Note4) The backlight life varries depending on the usage environment such as temperature, humidity or operating voltage.

Especially, if it is used at low temperatures, the life will be extremely short.

Note5) The sound output function is available for GT32T1 only.

Note6) An Ethernet port is available for GT32T1 only.

6-31

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.8.3 Function Specifications (GT32)

Specifications

Item

GT32M GT32T0/GT32T1

Displayable fonts

Character types

Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16)

(Double, quadruple or octuple in height and width)

True Type (GTWIN): 10 to 240 dots

Windows (R): 10 to 240 dots

English, Japanese, Korean, German, French, Italian, Spanish, Simplified

Chinese, Traditional Chinese characters and Turkish can be displayed.

Approx. 240 screens

Note1)

Approx. 180 screens

Note1)

Number of registerable screens

Registerable screen number

Graphics

Base screen: No. 0 to 3FF

Keyboard screen: No. 0 to 7

Login screen: No. 0 to F

Straight lines, continuous straight lines, squares, circles, ovals, arcs, elliptic arcs, fan shapes, elliptic fan shapes, beveled squares

Types of parts Switch

Function switch

Lamp

Message

Data

Bar graph

Note2) 3)

Clock

Line graph

Alarm list

Keyboard

Custom(message, lamp, switch)

Main functions

Note6)

Recipe

SD recipe

Through function

Flow display

Write device

Multi language exchange

Sound output

Note4)

Operation security

GT link

PLC multiple connection

Data logging

FP monitor

Connecting a computer to Ethernet port or USB port and our PLC to COM port enables the communication between the PLC and the computer. (This function is not available for PLCs manufactured by other companies.)

Note5)

Copy function

GTWIN ver.

Screen data can be copied with a SD memory card.

Ver. 2.80 or later

Note1) Maximum allowable number varies depending on registered contents.

Note2) External clock data can be referred and displayed.

Note3) Accuracy of the GT internal clock is ±180 seconds per month.

Note4) The sound output function is available for GT32T1 only.

Note5) An Ethernet port is available for GT32T1 only.

Note6) It depends on the version of GT.

6-32

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.8.4 Interface Specifications (GT32)

Interface for connecting PLC/External devices

- COM port

Specifications

Item

AIG32MQ02D/AIG32MQ03D

AIG32TQ02D/AIG32TQ03D

AIG32MQ04D/AIG32MQ05D

AIG32TQ04D/AIG32TQ05D

AIG32TQ12D/AIG32TQ13D AIG32TQ14D/AIG32TQ15D

Communication standard Conforms to RS232C

(Non insulation type)

Note1)

Conforms to RS422

(Non insulation type)

Note1)

Communication condition with external devices

Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps

Data length (bit) 7, 8

Parity

Stop bit (bit)

None, Odd, Even

1

Transmission distance

(Total length)

Protocol

Connector

Max. 15 m

(Baud rate: 19200 bit/s)

Max. 500 m

(Baud rate: 115200 bit/s)

-

-

MEWTOCOL (Protocol for PANASONIC PLC: FP series)

General-purpose serial (PANASONIC dedicated protocol)

-

Other companies' PLC protocols (For the details, refer to the latest

GTWIN HELP.)

Connector terminal base (8-pin)

Note2) 3)

Note1) It is internally isolated from the input power supply side (between +24V and 0V).

Note2) The (+) and (-) terminals are the power supply terminals for driving the main unit.

Note3) Regarding power supply voltage, please pay due consideration to the cable length so that the applied voltage is within the operation voltage range.

Interface for transferring screen data

- USB port

Item Specifications

Communication standard

Connector shape

Note1)

USB1.1

TYPE-B

Trasmission distance Max. 5 m

No. of connected unit with PC 1 unit

Note1) Take care of handling of the connector not to add an excessive static electricy on the metal part of the connector.

Note2) Screens can be transferred in one third less time via the Ethernet port.

(The speed varies depending on screen contents.)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Ethernet port (GT32T1 only)

Specifications

Item

Communication standard

Connector shape

GT32T1

IEEE802.8u/100BASE-TX IEEE802.3/10BASE-T

Note1)

Plug-in phone jack

Note2)

Transmission distance

Applicable cable

Auto MDI-X

SPEED lamp

Max. 100 m

UTP cable (Unshielded wire) Category 5

Note3)

Supported

Light on: During 100BASE-TX communication

Blinking: During 10BASE-TX communication

LINK/ACT lamp

Light on: When linked

Blinking: During data reception.

Note1) Data processing in the main unit is carried out with the serial communication of 115.2 kbps.

Note2) Take care of handling of the connector not to add an excessive static electricy on the metal part of the connector.

Note3) Do not use a STP cable (shielded wire).

Note4) Ethernet is a trademark of Zerox Corporation, USA.

Note5) Simultaneous communication with the USB port is not achievable.

SD memory card slot

Item

Support media

Supported format standard

Specifications

SD memory card, SDHC memory card

Note1)

Conforms to SD standard

Note2)

Note1) The manufacturer name that the operation check has done: Panasonic Corporation

Usable capacity of a SD memory card varies according to the version of GT firmware.

Note2) Please format with a format software for SD memory cards.

Note3) The SD access lamp turns on while acccessing the SD memory card.

6.8.5 Sound Output Specifications (GT32T1 Only)

Item

File format

Max. sound data capacity

Max. registered No. of sound data

Sound output voltage

Output terminal

Connecting amplifier

Specifications

GT32T1

WAV format (PCM format, sampling 8 KHz, 16 bits monoral)

512 kbytes (Approx. 30 seconds)

128

2 Vp-p

φ 3.5 stereo mini jack

Input impedance 10 kΩ or more

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.9 GT32-E

6.9.1 General Specifications (GT32-E)

Specifications

Item

GT32M-E GT32T-E

Rated voltage 24 V DC

Operating voltage range 21.6 to 26.4 V DC

Power consumption

Insulation method of power supply part

Ambient temperature

Ambient humidity

Storage temperature

Storage humidity

Breakdown voltage

Note2)

Insulation resistance

4.8 W or less (200 mA or less)

Transformer insulation

-20 to +60 C

Note1)

7.2 W or less (300 mA or less)

10 to 90% RH (at 25 C, non-condensing)

-20 to +60 C

10 to 90% RH (at 25 C, non-condensing)

Between [power supply terminals] and [case]

500 V AC for 1 minute, Cutoff current 10mA (at default setting)

Between [power supply terminals] and [case]

100 M or more, 500 V DC, measured with megohmmeter (at default setting)

Vibration resistance

Shock resistance

5 to 8.4 Hz half amplitude 3.5 mm

8.4 to 150 Hz acceleration 9.8 m/s2,

10 sweeps each in X, Y and Z directions (1 octave/min)

147 m/s

2

, 4 times on 3 axes

EC Directive applicable EN61131-2 (EMC Directive)

Noise immunity

Electrostatic discharge resistance

Protective construction

1000 V [P-P] or more, Pulse width 50 ns, 1s between power supply terminals (based on in-house measurements)

Note3)

6kV

(Contact Discharge, EN61000-4-2 Level 3)

IP67 (Initial value, evaluated by us)

Dustproof and drip-proof from front panel only (packing used on panel contact surface)

Note4)

Weight Approx. 470 g

Note1) When it is installed in a horizontal orientation (installed to make the liquid crystal face be topside), the usable range is -20 to +55 C.

Note2) Not isolated between the USB port, COM port and the internal digital circuit.

Note3) When using our exclusive cable.

Note4) When reattaching, replace waterproof packing.

6-35

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.9.2 Performance Specifications (GT32-E)

Item Specifications

GT32M-E GT32T-E

Display

Note1)

Touch switches

Display device

Resolution

TFT monochrome LCD

320 (W) x 240 (H) dots

Displayable area 115.2 (W) x 86.4 (H) mm

Backlight

Contrast

TFT color LCD

1-color LED backlight (white)

Can be adjusted on the menu screen, GTWIN configuration settings or PLC. (There are some minor variations in the backlight brightness.)

Analog touch switch (resistive film type) Touch switch

Touch switch operation

Life

0.8 N or less

1 million times or more (at 25 °C)

Note2)

F-ROM

SRAM

Note3)

Screen data (base, keyboard, login), Flow display data, FP monitor screen data: 12288 kbytes

Recipe data: 64 k bytes

Write device data: 64 kbytes

Memory

Alarm history + Line graph sampling (27.5 kbytes)

Logging data of Logging function (64 kbytes)

Hold GT Device (2048 + 255 words)

Hold PLC Device (24 words)

Built-in clock data

Alarm history data

Line graph sampling data

Logging data of Logging function

Battery

Note4)

Backup

Internal device hold data

Hold PLC Device data

Life Approx. 3 years (at 25 °C)

Note1) On the LCD panel, bright spots (points always lit) or black spots (points always unlit) may appear, or the uneven brightness, flickers or crosstalk (appearance of unintended shades in the area no graphic or part is arranged) may occur depending on the operating conditions. Note that these phenomena are resulted from the basic characteristics of LCD panel not defects or failures of the product.

Note2) The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.

Note3) A battery is necessary for SRAM backup.

The unused part of 27 kbytes for Alarm history and line graph sampling can be used for the logging function.

Note4) Please purchase a battery separately.

The battery life is the value when no power at all is supplied. The actual lifetime may be shorter according to the condition of use.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.9.3 Function Specifications (GT32-E)

Specifications

Item

GT32M-E GT32T-E

Displayable fonts

Character types

Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16)

(Double, quadruple or octuple in height and width)

True Type (GTWIN): 10 to 240 dots

Windows (R): 10 to 240 dots

English, Japanese, Korean, German, French, Italian, Spanish, Simplified

Chinese, Traditional Chinese characters and Turkish can be displayed.

Approx. 180 screens

Note1)

Number of registerable screens

Registerable screen number

Graphics

Base screen: No. 0 to 3FF

Keyboard screen: No. 0 to 7

Login screen: No. 0 to F

Straight lines, continuous straight lines, squares, circles, ovals, arcs, elliptic arcs, fan shapes, elliptic fan shapes, beveled squares

Types of parts Switch

Function switch

Lamp

Message

Data

Bar graph

Note2) 3)

Clock

Line graph

Alarm list

Keyboard

Custom(message, lamp, switch)

Main functions

Note4)

Recipe

SD recipe

Through function

Flow display

Write device

Multi language exchange

Operation security

GT link

PLC multiple connection

Data logging

FP monitor

Connecting a computer to USB port and our PLC to COM port enables the communication between the PLC and the computer.

Copy function

GTWIN ver.

Screen data can be copied with a SD memory card.

Ver. 2.C0 or later

Note1) Maximum allowable number varies depending on registered contents.

Note2) External clock data can be referred and displayed.

Note3) Accuracy of the GT internal clock is ±90 seconds per month (at 25 °C). Periodically set the clock to the right time for the system in which clock error is a problem.

Note4) It depends on the version of GT.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

6.9.4 Interface Specifications (GT32-E)

Interface for connecting PLC/External devices

- COM port

Specifications

Item AIG32MQ03DE AIG32MQ05DE

AIG32TQ03DE AIG32TQ05DE

Communication standard Conforms to RS232C

(Non insulation type)

Note1)

Conforms to RS422

(Non insulation type)

Note1)

Communication condition with external devices

Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps

Data length (bit) 7, 8

Parity

Stop bit (bit)

None, Odd, Even

1

Transmission distance

(Total length)

Protocol

Connector

Max. 15 m

(Baud rate: 19200 bit/s)

Max. 500 m

(Baud rate: 115200 bit/s)

-

MEWTOCOL (Protocol for PANASONIC PLC: FP series)

-

General-purpose serial (PANASONIC dedicated protocol)

-

Other companies' PLC protocols (For the details, refer to the latest

GTWIN HELP.)

Connector terminal base (8-pin)

Note2) 3)

Note1) It is internally isolated from the input power supply side (between +24V and 0V).

Note2) The (+) and (-) terminals are the power supply terminals for driving the main unit.

Note3) Regarding power supply voltage, please pay due consideration to the cable length so that the applied voltage is within the operation voltage range.

Interface for transferring screen data

- USB port

Item Specifications

Communication standard

Connector shape

Note1)

USB1.1

TYPE-B

Trasmission distance Max. 5 m

No. of connected unit with PC 1 unit

Note1) Take care of handling of the connector not to add an excessive static electricy on the metal part of the connector.

SD memory card slot

Item

Support media

Note1)

Supported format standard

Specifications

SD memory card, SDHC memory card

(The manufacturer name that the operation check has done:

Panasonic Corporation)

Conforms to SD standard

(Please format with a format software for SD memory cards.)

Note1) Check the usable temperature range of a SD memory card to be used before use.

.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Chapter 7

Dimensions and Other Documentation

7-1

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.1 Dimensions

7.1.1 GT01/GT01R

Installation dimensions Panel cutout dimensions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.1.2 GT02

Installation dimensions Panel cutout dimensions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.1.3 GT02L

Installation dimensions Panel cutout dimensions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.1.4 GT05

Installation dimensions Panel cutout dimensions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.1.5 GT11

Installation dimensions Panel cutout dimensions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.1.6 GT12

Installation dimensions Panel cutout dimensions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.1.7 GT21

Installation dimensions

Panel cutout dimensions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.1.8 GT32

GT32M Back view

GT32T0

GT32T1

Installation dimensions

Panel cutout dimensions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.1.9 GT32-E

Installation dimensions

Panel cutout dimensions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.2 Cable Specifications

7.2.1 AIGT8142

7.2.2 AIGT8152

7.2.3 AIGT8162/AIGT8165/AIGT8160

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.2.4 AIGT8175

7.2.5 AIP81842

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.3 Table of Screen Messages

Table of GT screen messages

In addition to screen data, the GT also displays the following messages.

When transferring data from personal computer to a GT

This is displayed when data is being transferred from the computer to the GT.

When transferring data from GT to a personal computer

This is displayed when data is being transferred from the GT to the computer.

When there is no base screen data

This is displayed when there is no base screen data. (It is displayed even if the configuration data has been sent.)

When the specified screen does not exist

This is displayed in cases such as when there is no data for a specified screen number.

"ESC" button is displayed at the top right of the screen to return to the previous screen.

When the screen memory is full

This is displayed if the internal user memory (F-ROM) is full.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.4 BIN/HEX/BCD Code Correspondence Table

Decimal Hexadecimal

28

29

30

31

24

25

26

27

63

255

9999

20

21

22

23

16

17

18

19

12

13

14

15

8

9

10

11

4

5

6

7

0

1

2

3

0018

0019

001A

001B

001C

001D

001E

001F

003F

00FF

270F

0010

0011

0012

0013

0014

0015

0016

0017

0008

0009

000A

000B

000C

000D

000E

000F

0000

0001

0002

0003

0004

0005

0006

0007

Binary

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00100111

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00000000

00010000

00010001

00010010

00010011

00010100

00010101

00010110

00010111

00011000

00011001

00011010

00011011

00011100

00011101

00011110

00011111

00111111

11111111

00001111

00000000

00000001

00000010

00000011

00000100

00000101

00000110

00000111

00001000

00001001

00001010

00001011

00001100

00001101

00001110

00001111

Binary Coded Decimal

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

1001

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0010

1001

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0000

0010

0010

0010

0010

0010

0010

0011

0011

0110

0101

1001

0001

0001

0001

0001

0010

0010

0010

0010

0000

0000

0001

0001

0001

0001

0001

0001

0000

0000

0000

0000

0000

0000

0000

0000

0100

0101

0110

0111

1000

1001

0000

0001

0011

0101

1001

0110

0111

1000

1001

0000

0001

0010

0011

1000

1001

0000

0001

0010

0011

0100

0101

0000

0001

0010

0011

0100

0101

0110

0111

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

7.5 ASCII Code Table

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Record of changes

Manual No.

ARCT1F511E

ARCT1F511E-1

ARCT1F511E-2

ARCT1F511E-3

ARCT1F511E-4

Date

Jul.2010

Dec.2010

Apr.2011

Aug.2011

Dec.2011

Desceiption of changes

First edition

Second edition

Third edition

Forth edition

- Added new model GT32-E

- Error correction

Fifth edition

-Added vertical type display function

( GT05/GT32/GT32-E)

-Added device change function

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

advertisement

Related manuals