Omega Altise Altise 4kW Portable Air Conditioner Instruction manual

Add to My manuals
16 Pages

advertisement

Omega Altise Altise 4kW Portable Air Conditioner Instruction manual | Manualzz

PORTABLE AIR CONDITIONER

OAPC1213

OAPC1413

1

__

SAFETY INSTRUCTIONS & CAUTION

__

Read all instructions carefully and keep this manual for future reference.

For indoor use only.

This appliance is designed for home air conditioning and must not be used for other purposes.

It is dangerous to modify the appliance in any way.

Switch off and unplug when not in use

If the appliance requires repair, contact a Service centre suggested by the manufacturer. Repairs carried out by unauthorised personnel may be dangerous.

If the power cable is damaged, it must be replaced by a qualified professional authorised by the manufacturer.

The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

Before cleaning or maintenance, always unplug the appliance from the mains socket.

Do not move the appliance by pulling the power cable.

Do not rest heavy or hot objects on top of the appliance.

Always transport the appliance upright.

Do not place objects on the unit or block the air inlet / outlet

To avoid electric shock, do not place the cord, the plug or the appliance in water or other liquids.

Do not insert fingers or other objects into the air conditioner during operation.

2

__

DESCRIPTION

___

1. Control panel 5. Filter

2. Air outlet grills 6. Evaporator air intake grill

3. Castors 7. Air exhaust hose housing

4. Handles 8. Condensate drain connection

9. Power Cable

10. Flange with cap 14. Castor locks

11. Suction caps 15. Remote control

12. Air exhaust hose 16. Window Slider

13. Window outlet

3

_

_

PREPARING FOR USE

__

ELECTRICAL CONNECTIONS

Before plugging the appliance into the mains socket, please check:

•The mains power supply corresponds to the value indicated on the rating plate on the back of the appliance;

•The mains socket and electrical circuit are adequate for the appliance;

The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible. Before use, make sure the air Intake and outlet grills are not obstructed.

AIR-CONDITIONING WITHOUT INSTALLATION

1. Fit the air exhaust hose [12] in the housing

[7] at the back of the appliance. Insert it as shown in figure A.

For optimum results:

If you have a sash window, place the bracket [16] on the window sill extend the bracket fully within the window frame, fix the bracket by using the pin then lower the window onto the bracket.

Insert the window outlet [13] of the exhaust hose [12] into the slot, then connect the hose to the air conditioner (fig. B).

4

_

_

PREPARING FOR USE

__

AIR-CONDITIONING WITHOUT INSTALLATION Cont.….

French window

Open the French window slightly and position the outlet [13] as shown in figure c.

Use the suction pads provided to hold the two parts of the window together (fig. D).

Keep the air hose as short and free of curves as possible to avoid constrictions.

5

_

_

PREPARING FOR USE

__

AIR-CONDITIONING SEMI-PERMANENT INSTALLATION

If required, your appliance can also be installed semi-permanently (fig.E)

Drill a hole ( 134 mm) in an outside wall or through a window pane. Respect the dimensions and

height of the hole given in figure F and G.

In the window pane

In the wooden kickboard of a

French window

In the wall: you are recommended to insulate the section of wall using suitable insulation.

Fit the wall flange [10] into the hole.

Fit the air exhaust hose in the relevant hose located on the rear side of the appliance. (fig. A page 4).

Fit the end of the hose to the wall flange [10] as shown in fig.G.

NOTE: When installing the air conditioner semi-permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation.

Keep the air hose as short and free of curves as possible to avoid constrictions.

6

G H I

_

_

CONTROL PANEL

__

J K L

M

N

B F A E C

A: ON/OFF button

B: MODE selection button

C: FAN speed selection button

D: Remote IR sensor

E: Programmed operation increase temperature/time button

F: Programmed operation decrease temperature/time button

G: COOL mode light

H: DEHUMIDIFYING mode light

I: FAN mode light

J: Display area

K: Auto-speed fan mode light

L: Low-speed fan mode light

M: Mid-speed fan mode light

N: High-speed fan mode light

7

D

_

_

OPERATION

__

Warning: If the air conditioner has been lying on its side, back or has been moved, leave it standing upright for at least 1 hour before plugging into the mains socket.

Plug into the mains socket, you will hear three beeps, two lines will also appear on the display indicating that the appliance is in standby.

Press the ON/STAND-BY button (A).

When turned on, the air conditioner starts operating in the same mode as when it was turned off.

Press the MODE button (B) until the light corresponding to the required mode lights up.

Light (G)

Light (H)

: cool mode

: dehumidifying mode

Light (I) : fan mode

COOL MODE

Ideal for hot muggy weather when you need to cool and dehumidify the room. To set operation of the appliance correctly, press the (E) or (F) buttons until the desired temperature is displayed.

Then select the fan speed by pressing the (C) button until the light corresponding to the required fan speed lights up:

HIGH: the cool operates at maximum to reach the required temperature as rapidly as possible

MED: reduces noise levels but still maintains a good level of comfort

LOW: for silent operation

AUTO: the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display.

The most suitable temperature for the room during the summer varies from 24 to 27 o

C

DEHUMIDIFYING MODE

Ideal for reducing humidity in spring and autumn , during rainy spells or in damp rooms, etc.

In dehumidifying mode, the appliance must have the same configuration as for the air conditioning mode , with the air exhaust hose fitted to the appliance to allow air to be discharged externally.

When the dehumidifying mode is selected, the light (I) comes on and "dh" appears on the display.

At the same time, the AUTO fan light (J) comes on. In this mode, other speeds cannot be selected.

FAN MODE

Adjust the fan speed by pressing

In this mode, Auto cannot be selected.

The fan speed will be displayed. button (C) as described for the cool mode.

8

_

_

USING THE REMOTE CONTROL

__

DESCRIPTION OF THE REMOTE CONTROL

1) FAN button

2) ON/OFF button

3) MODE button

4) TIMER button

5) Display

Point the remote to the remote IR sensor on the air conditioner.

The remote works at a max distance of 7 meters

Replacing the batteries

Remove the cover on the rear of the remote control;

Remove the old batteries if present.

Insert two new R03“AAA” 1.5v batteries, inserting them correctly (see the instructions inside the battery compartment);

Replace the battery cover

Caution: If the remote is replaced or discarded, the batteries must be removed and disposed.

Caution: Do not mix old and new batteries

Caution: do not mix alkaline, standard

(carbon-zinc) or rechargeable batteries

Caution: Do not dispose batteries in fire.

They may explode or leak.

9

_

_

USING THE REMOTE CONTROL

_

TURNING THE APPLIANCE ON

Plug into the mains socket.

Press the ON/OFF button (2) (when turned on, the air conditioner starts operating in the same mode as when it was turned off).

Press the MODE button (3) to select the required mode

AIR-CONDITIONING (COOL)

DEHUMIDIFYING (DRY)

FAN ONLY (FAN)

An arrow on the display indicates the selected mode.

AIR-CONDITIONING MODE (COOL)

Ideal for hot humid weather when you need to cool and dehumidify the room.

In air-conditioning mode, use the buttons to select the desired temperature.

The display shows the set temperature.

To change the fan speed, use the FAN button 1 on the remote control, choosing from the available speeds:

AUTO: the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display.

HIGH: the air conditioner operates at maximum to reach the required temperature as rapidly as possible

MED: reduces noise levels but still maintains a good level of comfort

LOW: for silent operation

Two arrows on the display indicate respectively COOL and the fan speed.

The most suitable temperature for the room during the summer varies from 24 to 27 o

C.

DEHUMIDIFYING MODE (DRY)

Ideal to reduce room humidity (spring and autumn, damp rooms, rainy periods, etc). In dehumidifying mode, the appliance selects fan speed automatically.

Two arrows on the remote control display indicate DRY and AUTO respectively.

FAN MODE ONLY (FAN)

In fan mode, fan speed can be set by pressing the FAN button 1.

The fan speed changes between the speeds available (LOW/MED/HIGH).

Two arrows on the display indicate FAN mode and the speed set.

In this mode, AUTO speed cannot be selected.

10

_

_

USING THE REMOTE CONTROL

_

SETTING THE TIMER

The timer can be used to delay appliance start up or shut down. This avoids wasting electricity by optimising operating periods.

How to programme delayed shutdown

With the air-conditioning unit on, press the TIMER button 4. The time is displayed and the "h" symbol flashes, with a flashing arrow indicating TIMER OFF.

Set the time when you want the appliance to go off using the

24 hours). buttons (from 30 minutes to

During the first ten hours, you can select half hour intervals. For times greater than ten hours, one hour intervals can be selected.

Press the TIMER button again to confirm the selection. The appliance emits a beep and the light (H) flashes on the control panel, confirming successful activation of the timer. A count- down of the time left is displayed on the remote control display and the light (H) flashes on the air conditioner display.

At the end of the set time the appliance switches off automatically.

To cancel the timer programme, press the TIMER button again. The appliance emits a beep and both displays reset to display the settings prior to activation of the timer.

How to programme delayed start up

With the air conditioner off, press the TIMER button. An arrow indicating TIMER ON flashes on the display. Now make all the desired settings for when the appliance will switch on (operating mode, fan speed and temperature). Confirm the settings by pressing the TIMER button. The time is displayed and the "h" symbol flashes.

Set the time when you want the appliance to switch off using the button

24 hours).

(from 30 minutes to

During the first ten hours, you can select half hour intervals. For times greater than ten hours, one hour intervals can be selected.

Press the TIMER button again to confirm the start-up time. A beep sounds and the time set is also

displayed on the control panel, confirming setting of the timer. The light (H) flashes on the air conditioner display. A countdown of the time left is displayed on both displays.

At the end of the set time the appliance switches on automatically, with the settings made previously.

To cancel the timer programme, press the TIMER button again. The appliance emits a beep and both displays reset to stand-by.

11

_

TIPS

__

To get the best from your air conditioner, follow these recommendations:

Close the windows and doors in the room to be air conditioned.

The only exception is when the appliance is installed through a hole in the wall.

In this case, you are recommended to leave a slight draught through a door or window to guarantee

correct ventilation.

Never use the appliance in very damp rooms (laundries for example).

Never use the appliance outdoors.

Protect the room from direct exposure to the sun by partially closing curtains and/or blinds to make the appliance much more economical to run.

Never rest objects of any kind on the air conditioner.

Never obstruct the air intake [ 6 ] or outlet grills [1].

Make sure there are no heat sources in the room.

Make sure the air conditioner is on a level floor. If necessary, place the two castor locks [14] under the front wheels [3]

Do not cover the appliance

12

_

TIPS

__

WATER DRAINAGE METHOD

Water drainage will generally only be required when you store the air conditioner away or when not in use.

NOTE

As a safety measure, to positively prevent water spillage, the air conditioner is equipped with a fail-safe

“(FULL TANK) device, if, the water tank fills. The unit will completely stop, the control panel displays” the compressor and fan will not restart until the tank has been drained.

INTERMITTENT DRAINAGE (fig.h)

Turn the air conditioner off, and then drain the water tank by unplugging the drain cap and allowing the water to flow onto a drain pan. It may be easier to wheel the unit outside, remove the drain cap and drain the water onto the ground freely.

The water tank is considered sufficiently drained when no more water flows from the drain outlet.

To completely drain all water from the water tank, tilt the unit by lifting it slightly upwards from the front until no more water drains from the outlet.

Restart the air conditioner by pressing the on/off button. Ensure that the unit is in COOL or DRY mode. The compressor will start approximately 3 minutes after the unit is switched on.

Fig.h

13

_

CLEANING

__

Before cleaning or maintenance, turn the appliance off by pressing the ON/OFF button [A] then unplug the appliance from the mains socket.

CLEANING THE CABINET

You should clean the appliance with a slightly damp cloth then dry with a dry cloth.

For safety reasons, never wash the air conditioner with water.

Caution: Never use petrol, alcohol or solvents to clean the appliance. Never spray liquids or similar.

CLEANING THE AIR FILTERS

To keep your air conditioner working efficiently, you should clean the dust filter every week of operation.

The filter is housed in the intake grill.

To clean the filters proceed as follows:

Remove the dust filter by extracting it upwards (figure. h ).

Use a vacuum cleaner to remove dust accumulations from the filter. If it is very dirty, wash in warm water and rinse. The water should never be hotter than 40°C.

After washing, leave the filter to dry, and then put back in place.

Fig.h

14

_

TROUBLESHOOTING

__

Wait for three minutes

15

Omega Altise products are distributed in

Australia by Shriro Australia Pty Ltd.

Locked Bag 5002, Kingsgrove NSW 2208

Phone: 1300 795 572 Fax: (02) 9415 5525

Web: www.omegaaltise.com.au

16

advertisement

Related manuals

advertisement