FURUNO DFF3-UHD Installation Manual

Add to My manuals
16 Pages

advertisement

FURUNO DFF3-UHD Installation Manual | Manualzz

Installation Manual

NETWORK FISH FINDER

Model

DFF3-UHD

A Word to the Owner of the DFF3-UHD

Congratulations on your choice of the FURUNO DFF3-UHD Network Fish Finder. The DFF3-UHD is a network fish finder designed for use with the NavNet TZtouch3 (TZT9F/12F/16F/19F, Ver. 3.01 or higher) and

NavNet TZtouch2 (TZT2BB only, Ver.9.01 or higher). Please carefully read and follow the recommended procedures for installation and maintenance. Thank you for considering and purchasing FURUNO.

Operational Cautions

• A separate power supply is required. Take the power from the ship's mains via the ship's switchboard.

• The DFF3-UHD is not turned off when the multi function display is powered off. The DFF3-UHD's standby power is 6.2 W, so turn it off from the ship’s switchboard when it is not in use.

• DFF3-UHD does not support the Bottom Discrimination, RezBoost, or ACCU-FISH.

• Do not transmit with the transducer out of water, to prevent damage to the transducer.

• Use the multi function display to change the program version of the power amp. Contact FURUNO for information on how to upgrade program version.

• When using two types of transducers, set them from [Fishfinder]-[Transducer Setup]-[Transducer Setup]-

[Type] of the NavNet TZtouch3 and NavNet TZtouch2. Because the equipment has only one TDID port, two TDIDs cannot be read.

• The following concern acts as our importer in Europe, as defined in DECISION No 768/2008/EC.

- Name: FURUNO EUROPE B.V.

- Address: Ridderhaven 19B, 2984 BT Ridderkerk, The Netherlands

• The following concern acts as our importer in UK, as defined in SI 2016/1025 as amended SI 2019/470.

- Name: FURUNO (UK) LTD.

- Address: West Building Penner Road Havant Hampshire PO9 1QY, U.K.

Safety Instructions

The installer must read the safety instructions before attempting to install the equipment.

WARNING

CAUTION

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury.

Warning, Caution

WARNING

Do not disassemble or modify the equipment.

Fire, electrical shock or serious injury can result.

Use the proper fuse.

Use of a wrong fuse can damage the equipment and may cause fire.

12VDC

7.5 A

24VDC

7.5 A

Prohibitive Action Mandatory Action

CAUTION

Observe the following compass safe distance to prevent interference to a magnetic compass:

Standard compass Steering compass

0.35 m 0.3 m

www.furuno.com

All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Equipment List

Name

Network Fish Finder

Installation Materials

Type

DFF3-UHD

CP02-09900

Code No.

Qty

-

000-038-530

Remark

1

1 - FRU-3P-FF-A002M-001

(Cable assembly, 001-197-

092-10)

- MOD-Z071-050+ (LAN cable, 001-167-890-10)

- CP02-09901 (EMI core and Self-tapping screw,

001-621-550)

Option

Name

Extension Cable

LAN Cable

Transducer

Thru-Hull Pipe

AC/DC Power Supply Unit

Ferrite Core

Type

C44-02 30M

C44-02 50M

C334 30M

MOD-Z072-020+

MOD-Z072-100+

PM111LHG

CM599LHG

TFB-7000(1)

PR-241

OP86-11

Code No.

Qty

000-190-455

000-190-454

000-190-456

000-167-175

000-167-177

000-027-404

000-027-406

000-022-532

-

001-594-450

Remark

1 For tank w/transducer

1 (CM265LH, CM265LM,

CM599LH, CM599LM,

PM111LH, PM111LM,

CM275LH-W)

1 For thru-hull transducer.

1 2 m

1 10 m

1 2 kW 38-75/130-210 kHz

1 2 kW 28-60/130-210 kHz

1

1

1 For PR-241

CE/UKCA Declaration

With regards to CE/UKCA declarations, please refer to our website (www.furuno.com) for further information about RoHS conformity declarations.

Disclosure of Information about China RoHS

With regards to China RoHS information for our products, please refer to our website

(www.furuno.com).

Installation

Select the mounting location considering the following points.

• Locate the unit away from areas subject to water splash.

• Select a location that is well ventilated.

• Observe the compass safe distances shown on page 1.

• Leave the sufficient service clearance around the unit.

2

Procedure

1. Drill four pilot holes in the bulkhead (or tabletop) for the self-tapping screws.

2. Screw two self-tapping screws (  5x20) into the pilot holes for upper, leave 5 mm protruding.

3. Set unit onto the screws and fasten them.

Bulkhead mount

Tabletop mount

4. Tightly fasten the other two screws to fix the unit in place.

NOTE:

For mounting on a bulkhead, the connectors must face downward.

OK NO

Wiring

Wiring Outline

The figure below shows the inserting position of each cables for the DFF3-UHD. Refer to the interconnection diagram for details.

Super gland Seal nut

POWER EXT-KP NETWORK Transducer Transducer

Grounding terminal

Inserting position of cables

3

Procedure

1. Remove the cover.

2. Unfasten four screws to remove the chassis cover.

[Transducer cable wiring]

3. Fabricate the transducer cable(s) as shown below.

Fabricate the cables for both the high and low frequencies. For a CHIRP transducer, fabricate the ID signal cores for both the high and low frequencies.

6

Sheath

Braided shield

Wrap the shield onto the sheath.

6

Braided shield

Co

Drain w

Vinyl tape

(10 mm)

Clamp here

(on step 10).

Single frequency transducer cable

Vinyl tape

(10 mm)

Clamp here

(on step 10).

CHIRP transducer cable

4. Unfasten the seal nut on the cable entry for transducer cable.

5. Pass the seal nut, claw and seal onto the transducer cable, in that order.

6. Push the seal assembly into the seal nut, then tighten the super gland.

7. Remove the WAGO connectors from the PCB, then attach the transducer cable to the connector.

Push

Terminal opener

Procedure

1. Twist core.

2. Insert terminal opener and push.

3. Insert a core into hole.

4. Release the terminal opener.

5. Pull the core to confirm it is correctly inserted.

Core

WAGO

Connector

Twist

8. Clamp the braided shield with a cable clamp.

4

9. Attach the WAGO connector to the PCB.

For two sets of single frequency transducers

LF HF TDID

KP

LAN

Clamp the shield

For CHIRP transducer

KP

LAN

LF HF TDID

Clamp the shield

Source

Source

External KP signal cable

LAN

Cable

Make loop

LF HF

Transducer cable

External KP signal cable

LAN

Cable

CHIRP transducer

Make loop

[LAN cable and external KP signal cable wiring]

10. Connect the LAN cable to the LAN connector.

As shown in the above figure, make a loop in the cable (approx. 10mm diameter), then connect the cable.

11. Fasten the seal nut to fix the transducer cable.

The torque shall be 2.0 Nm and the gap between the seal nut and the super gland shall be approx. 3 mm.

12. Fabricate the external KP signal cable as shown below. (core size 0.75 sq, outer dia 7.6 approx.)

External KP signal cable (local supply)

VCTF0.75x4C

Sheath 6

φ6.5

㻌㼠㼛㻌

φ12.5

13. Pass the cable through the seal nut and seal assembly, like you did with the transducer cable.

14. Push the seal assembly into the seal nut, then tighten the super gland.

15. Remove the WAGO connector from the PCB and connect it to the external KP signal cable.

16. Connect WAGO connector to the PCB.

17. Tighten the seal nut to fasten the cable.

18. Attach the EMI core (GRFC-8, supplied) to the power cable near the super gland to prevent noise (see figure below).

10 mm

EMI core

External KP signal cable

19. Attach the ground wire (IV-1.25sq, local supply) to the ground terminal with a crimp-on lug (M3, local supply) to prevent interference.

20. Reattach the chassis cover.

21. Reattach the cover.

5

Operation Check

For NavNet TZtouch3 and NavNet TZtouch2, the DFF3-UHD is powered on/off from the ship’s switchboard.

The STATUS LED and ERROR LED on the bottom of the DFF3-UHD lights or blinks according to equipment state, as described in the table below.

LED Type

LED State

STATUS

Blinking every two seconds

Blinking every 0.4 seconds

Off

Off

ERROR Meaning

Normal operation

Off

Transducer settings at NavNet device not properly set.

Lit continuously Communication error with

NavNet device or internal fan error (see “Troubleshooting” about how to solve the problem).

㻿㼀㻭㼀㼁㻿㻌 㻱㻾㻾㻻㻾

LED Position

Troubleshooting

The table below provides basic troubleshooting procedures which the user may follow to restore normal operation. If you cannot restore normal operation, do not check inside unit. Have a FURUNO dealer check the equipment

.

Problem

Cannot turn on power.

No echo appears but fixed range scale appears.

Sensitivity is low.

ERROR LED turns on.

Reason

• The power cable is disconnected or damaged. Check the power cable and if it damaged, replace it.

• Check the ship’s mains and check if the switchboard is turned on.

• Check the fuse on the power cable. If the fuse has blown, find the cause then replace it.

• The sensor cable is disconnected or damaged.

Check the cable and reconnect or replace it as necessary.

• Gain setting is too low. Raise the gain.

• Marine life is adhering to the transducer face. Clean the transducer face.

• Vessel is in heavily sedimented water.

• Disconnect the Power cable and LAN cable.

• Connect the Power cable and LAN cable.

• Contact your local dealer for advice when the problem cannot be solved.

6

Specifications

Frequency

Number of channels

Output power

25 to 242 kHz

2 ch

3 kW

12-24 VDC: 3.0-1.6 A Power supply

Environmental conditions

Ambient temperature

Degree of protection

-15°C to +55°C

IP55

Vibration IEC60945 Ed.4

External KP Input 5-12 VDC, Positive

External KP Output 12 VDC, Positive

Transducer List

The below shows the transducers that can be connected.

Note: CHIRP transducers (dual frequency) are the products of AIRMAR Technology Corporation.

CHIRP transducers (dual frequency)

R109LM PM411LWM

R109LH

R109LHW

R111LM

R111LH

CM599LM

CM599LH/

CM599LHG

CM599LHW

R409LWM

PM111LM

PM111LH

PM111LHG

PM111LHW

R509LM

R509LH

R509LHW

R599LM

R599LH

165T-PM542LM

165T-PM542LHW

Standard transducers (CW narrow band)

28BL-6HR 68F-30H

28BL-12HR

28F-38M

28F-72

38BL-9HR

82B-35R

88B-10

88F-126H

100B-10R

38BL-15HR

50BL-12HR

50BL-24HR

50F-38

50F-70

150B-12H

200B-8

200B-8B

200B-12H

Licensed Software

This product includes software licensed under BSD-3-Clause and others. Please refer to the following for details on the terms of the software.

Intel-socfpga-hwlib

Copyright 2013-2020 Intel Corporation. All Rights Reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.

3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"AND

ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE

DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR

7

ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES

(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;

LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON

ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING

NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN

IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

Altera-SoCFPGA-HardwareLib-MPL

Altera MPL preloader, configured for use with SDMMC/Connectal. (The initial commit is the unmodified sourcecode from Altera)

The original source was extracted from: altera/14.1/embedded/examples/software/Altera-SoCFPGA-

HardwareLib-MPL.tar.gz and has BSD copyright with the additional restriction: "This software may only be used to run on Altera products, or to program Altera devices."

All subsequent edits by Cambridgehackers are under the same copyright.

8

PACKING LIST

DFF3-UHD

ユニット

ネットワーク魚探

N A M E

UNIT

O U T L I N E

NETWORK FISH FINDER

工事材料

ケーブル(組品)

CABLE ASSEMBLY

INSTALLATION MATERIALS

ケーブル(組品)LAN

LAN CABLE ASSEMBLY

工事材料袋詰

INSTALLATION MATERRIALS

図書

装備要領書(英)

INSTALLATION MANUAL (EN)

DOCUMENT

02HA-X-9851 -0 1/1

A-1

DESCRIPTION/CODE № Q'TY

1 DFF3-UHD

000-038-529-00

FRU-3P-FF-A002M-001

000-197-092-10

MOD-Z072-050+

001-167-890-10

CP02-09901

001-621-550-00

IME-20410-*

000-199-256-1*

1

1

1

1

(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

C2041-Z01-A

3/Feb/2022 H.MAKI

D-1

1&

1&

7%

1&

6+,(/'

6+,(/'

;'5B+)

*1'

;,'

7(03

;'5B+)

7%

1&

1&

6+,(/'

;'5B/)

;'5B/)

7%

%/.:+7

'5$,1

%/8

<(/

%/.

%/8:+7

'5$,1

%51

25*

:+7

'5$,1

࢔࢜

ࢳࣕ

ࢲ࢖

ࢩࣟ

㺏㺓㺚㺹

ࢡࣟ

㺖㺹㺚㺹

P

S-1

9-52 Ashihara-cho,

Nishinomiya, 662-8580, JAPAN

All rights reserved.

Printed in Japan

Pub. No. IME-20410-B1

(TEHI ) DFF3-UHD

・FURUNO Authorized Distributor/Dealer

A : FEB .

2022

B1 : NOV . 01, 2022

0 0 0 1 9 9 2 5 6 1 2

advertisement

Related manuals