FURUNO DFF3-UHD Installation Manual
Add to My manuals16 Pages
Furuno DFF3-UHD is a network fish finder designed for use with NavNet TZtouch3 and NavNet TZtouch2. It features two channels, 3 kW output power, and a frequency range of 25 to 242 kHz. It supports a variety of transducers, including CHIRP transducers. With the DFF3-UHD, you can easily find fish and underwater structures, even in deep water or in areas with heavy sedimentation. Its advanced signal processing technology provides clear and detailed images of the underwater world, helping you to identify fish species and locate productive fishing spots.
advertisement
Installation Manual
NETWORK FISH FINDER
Model
DFF3-UHD
A Word to the Owner of the DFF3-UHD
Congratulations on your choice of the FURUNO DFF3-UHD Network Fish Finder. The DFF3-UHD is a network fish finder designed for use with the NavNet TZtouch3 (TZT9F/12F/16F/19F, Ver. 3.01 or higher) and
NavNet TZtouch2 (TZT2BB only, Ver.9.01 or higher). Please carefully read and follow the recommended procedures for installation and maintenance. Thank you for considering and purchasing FURUNO.
Operational Cautions
• A separate power supply is required. Take the power from the ship's mains via the ship's switchboard.
• The DFF3-UHD is not turned off when the multi function display is powered off. The DFF3-UHD's standby power is 6.2 W, so turn it off from the ship’s switchboard when it is not in use.
• DFF3-UHD does not support the Bottom Discrimination, RezBoost, or ACCU-FISH.
• Do not transmit with the transducer out of water, to prevent damage to the transducer.
• Use the multi function display to change the program version of the power amp. Contact FURUNO for information on how to upgrade program version.
• When using two types of transducers, set them from [Fishfinder]-[Transducer Setup]-[Transducer Setup]-
[Type] of the NavNet TZtouch3 and NavNet TZtouch2. Because the equipment has only one TDID port, two TDIDs cannot be read.
• The following concern acts as our importer in Europe, as defined in DECISION No 768/2008/EC.
- Name: FURUNO EUROPE B.V.
- Address: Ridderhaven 19B, 2984 BT Ridderkerk, The Netherlands
• The following concern acts as our importer in UK, as defined in SI 2016/1025 as amended SI 2019/470.
- Name: FURUNO (UK) LTD.
- Address: West Building Penner Road Havant Hampshire PO9 1QY, U.K.
Safety Instructions
The installer must read the safety instructions before attempting to install the equipment.
WARNING
CAUTION
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury.
Warning, Caution
WARNING
Do not disassemble or modify the equipment.
Fire, electrical shock or serious injury can result.
Use the proper fuse.
Use of a wrong fuse can damage the equipment and may cause fire.
12VDC
7.5 A
24VDC
7.5 A
Prohibitive Action Mandatory Action
CAUTION
Observe the following compass safe distance to prevent interference to a magnetic compass:
Standard compass Steering compass
0.35 m 0.3 m
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
Equipment List
Name
Network Fish Finder
Installation Materials
Type
DFF3-UHD
CP02-09900
Code No.
Qty
-
000-038-530
Remark
1
1 - FRU-3P-FF-A002M-001
(Cable assembly, 001-197-
092-10)
- MOD-Z071-050+ (LAN cable, 001-167-890-10)
- CP02-09901 (EMI core and Self-tapping screw,
001-621-550)
Option
Name
Extension Cable
LAN Cable
Transducer
Thru-Hull Pipe
AC/DC Power Supply Unit
Ferrite Core
Type
C44-02 30M
C44-02 50M
C334 30M
MOD-Z072-020+
MOD-Z072-100+
PM111LHG
CM599LHG
TFB-7000(1)
PR-241
OP86-11
Code No.
Qty
000-190-455
000-190-454
000-190-456
000-167-175
000-167-177
000-027-404
000-027-406
000-022-532
-
001-594-450
Remark
1 For tank w/transducer
1 (CM265LH, CM265LM,
CM599LH, CM599LM,
PM111LH, PM111LM,
CM275LH-W)
1 For thru-hull transducer.
1 2 m
1 10 m
1 2 kW 38-75/130-210 kHz
1 2 kW 28-60/130-210 kHz
1
1
1 For PR-241
CE/UKCA Declaration
With regards to CE/UKCA declarations, please refer to our website (www.furuno.com) for further information about RoHS conformity declarations.
Disclosure of Information about China RoHS
With regards to China RoHS information for our products, please refer to our website
(www.furuno.com).
Installation
Select the mounting location considering the following points.
• Locate the unit away from areas subject to water splash.
• Select a location that is well ventilated.
• Observe the compass safe distances shown on page 1.
• Leave the sufficient service clearance around the unit.
2
Procedure
1. Drill four pilot holes in the bulkhead (or tabletop) for the self-tapping screws.
2. Screw two self-tapping screws ( 5x20) into the pilot holes for upper, leave 5 mm protruding.
3. Set unit onto the screws and fasten them.
Bulkhead mount
Tabletop mount
4. Tightly fasten the other two screws to fix the unit in place.
NOTE:
For mounting on a bulkhead, the connectors must face downward.
OK NO
Wiring
Wiring Outline
The figure below shows the inserting position of each cables for the DFF3-UHD. Refer to the interconnection diagram for details.
Super gland Seal nut
POWER EXT-KP NETWORK Transducer Transducer
Grounding terminal
Inserting position of cables
3
Procedure
1. Remove the cover.
2. Unfasten four screws to remove the chassis cover.
[Transducer cable wiring]
3. Fabricate the transducer cable(s) as shown below.
Fabricate the cables for both the high and low frequencies. For a CHIRP transducer, fabricate the ID signal cores for both the high and low frequencies.
6
Sheath
Braided shield
Wrap the shield onto the sheath.
6
Braided shield
Co
Drain w
Vinyl tape
(10 mm)
Clamp here
(on step 10).
Single frequency transducer cable
Vinyl tape
(10 mm)
Clamp here
(on step 10).
CHIRP transducer cable
4. Unfasten the seal nut on the cable entry for transducer cable.
5. Pass the seal nut, claw and seal onto the transducer cable, in that order.
6. Push the seal assembly into the seal nut, then tighten the super gland.
7. Remove the WAGO connectors from the PCB, then attach the transducer cable to the connector.
Push
Terminal opener
Procedure
1. Twist core.
2. Insert terminal opener and push.
3. Insert a core into hole.
4. Release the terminal opener.
5. Pull the core to confirm it is correctly inserted.
Core
WAGO
Connector
Twist
8. Clamp the braided shield with a cable clamp.
4
9. Attach the WAGO connector to the PCB.
For two sets of single frequency transducers
LF HF TDID
KP
LAN
Clamp the shield
For CHIRP transducer
KP
LAN
LF HF TDID
Clamp the shield
Source
Source
External KP signal cable
LAN
Cable
Make loop
LF HF
Transducer cable
External KP signal cable
LAN
Cable
CHIRP transducer
Make loop
[LAN cable and external KP signal cable wiring]
10. Connect the LAN cable to the LAN connector.
As shown in the above figure, make a loop in the cable (approx. 10mm diameter), then connect the cable.
11. Fasten the seal nut to fix the transducer cable.
The torque shall be 2.0 Nm and the gap between the seal nut and the super gland shall be approx. 3 mm.
12. Fabricate the external KP signal cable as shown below. (core size 0.75 sq, outer dia 7.6 approx.)
External KP signal cable (local supply)
VCTF0.75x4C
Sheath 6
φ6.5
㻌㼠㼛㻌
φ12.5
13. Pass the cable through the seal nut and seal assembly, like you did with the transducer cable.
14. Push the seal assembly into the seal nut, then tighten the super gland.
15. Remove the WAGO connector from the PCB and connect it to the external KP signal cable.
16. Connect WAGO connector to the PCB.
17. Tighten the seal nut to fasten the cable.
18. Attach the EMI core (GRFC-8, supplied) to the power cable near the super gland to prevent noise (see figure below).
10 mm
EMI core
External KP signal cable
19. Attach the ground wire (IV-1.25sq, local supply) to the ground terminal with a crimp-on lug (M3, local supply) to prevent interference.
20. Reattach the chassis cover.
21. Reattach the cover.
5
Operation Check
For NavNet TZtouch3 and NavNet TZtouch2, the DFF3-UHD is powered on/off from the ship’s switchboard.
The STATUS LED and ERROR LED on the bottom of the DFF3-UHD lights or blinks according to equipment state, as described in the table below.
LED Type
LED State
STATUS
Blinking every two seconds
Blinking every 0.4 seconds
Off
Off
ERROR Meaning
Normal operation
Off
Transducer settings at NavNet device not properly set.
Lit continuously Communication error with
NavNet device or internal fan error (see “Troubleshooting” about how to solve the problem).
㻿㼀㻭㼀㼁㻿㻌 㻱㻾㻾㻻㻾
LED Position
Troubleshooting
The table below provides basic troubleshooting procedures which the user may follow to restore normal operation. If you cannot restore normal operation, do not check inside unit. Have a FURUNO dealer check the equipment
.
Problem
Cannot turn on power.
No echo appears but fixed range scale appears.
Sensitivity is low.
ERROR LED turns on.
Reason
• The power cable is disconnected or damaged. Check the power cable and if it damaged, replace it.
• Check the ship’s mains and check if the switchboard is turned on.
• Check the fuse on the power cable. If the fuse has blown, find the cause then replace it.
• The sensor cable is disconnected or damaged.
Check the cable and reconnect or replace it as necessary.
• Gain setting is too low. Raise the gain.
• Marine life is adhering to the transducer face. Clean the transducer face.
• Vessel is in heavily sedimented water.
• Disconnect the Power cable and LAN cable.
• Connect the Power cable and LAN cable.
• Contact your local dealer for advice when the problem cannot be solved.
6
Specifications
Frequency
Number of channels
Output power
25 to 242 kHz
2 ch
3 kW
12-24 VDC: 3.0-1.6 A Power supply
Environmental conditions
Ambient temperature
Degree of protection
-15°C to +55°C
IP55
Vibration IEC60945 Ed.4
External KP Input 5-12 VDC, Positive
External KP Output 12 VDC, Positive
Transducer List
The below shows the transducers that can be connected.
Note: CHIRP transducers (dual frequency) are the products of AIRMAR Technology Corporation.
CHIRP transducers (dual frequency)
R109LM PM411LWM
R109LH
R109LHW
R111LM
R111LH
CM599LM
CM599LH/
CM599LHG
CM599LHW
R409LWM
PM111LM
PM111LH
PM111LHG
PM111LHW
R509LM
R509LH
R509LHW
R599LM
R599LH
165T-PM542LM
165T-PM542LHW
Standard transducers (CW narrow band)
28BL-6HR 68F-30H
28BL-12HR
28F-38M
28F-72
38BL-9HR
82B-35R
88B-10
88F-126H
100B-10R
38BL-15HR
50BL-12HR
50BL-24HR
50F-38
50F-70
150B-12H
200B-8
200B-8B
200B-12H
Licensed Software
This product includes software licensed under BSD-3-Clause and others. Please refer to the following for details on the terms of the software.
Intel-socfpga-hwlib
Copyright 2013-2020 Intel Corporation. All Rights Reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"AND
ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR
7
ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON
ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING
NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN
IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Altera-SoCFPGA-HardwareLib-MPL
Altera MPL preloader, configured for use with SDMMC/Connectal. (The initial commit is the unmodified sourcecode from Altera)
The original source was extracted from: altera/14.1/embedded/examples/software/Altera-SoCFPGA-
HardwareLib-MPL.tar.gz and has BSD copyright with the additional restriction: "This software may only be used to run on Altera products, or to program Altera devices."
All subsequent edits by Cambridgehackers are under the same copyright.
8
PACKING LIST
DFF3-UHD
ユニット
ネットワーク魚探
N A M E
UNIT
O U T L I N E
NETWORK FISH FINDER
工事材料
ケーブル(組品)
CABLE ASSEMBLY
INSTALLATION MATERIALS
ケーブル(組品)LAN
LAN CABLE ASSEMBLY
工事材料袋詰
INSTALLATION MATERRIALS
図書
装備要領書(英)
INSTALLATION MANUAL (EN)
DOCUMENT
02HA-X-9851 -0 1/1
A-1
DESCRIPTION/CODE № Q'TY
1 DFF3-UHD
000-038-529-00
FRU-3P-FF-A002M-001
000-197-092-10
MOD-Z072-050+
001-167-890-10
CP02-09901
001-621-550-00
IME-20410-*
000-199-256-1*
1
1
1
1
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C2041-Z01-A
3/Feb/2022 H.MAKI
D-1
1&
1&
7%
1&
6+,(/'
6+,(/'
;'5B+)
*1'
;,'
7(03
;'5B+)
7%
1&
1&
6+,(/'
;'5B/)
;'5B/)
7%
%/.:+7
'5$,1
%/8
<(/
%/.
%/8:+7
'5$,1
%51
25*
:+7
'5$,1
࢜
ࢳࣕ
ࢲ
ࢩࣟ
࢟
㺏㺓㺚㺹
ࢡࣟ
㺖㺹㺚㺹
P
S-1
9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN
All rights reserved.
Printed in Japan
Pub. No. IME-20410-B1
(TEHI ) DFF3-UHD
・FURUNO Authorized Distributor/Dealer
A : FEB .
2022
B1 : NOV . 01, 2022
0 0 0 1 9 9 2 5 6 1 2
advertisement
Related manuals
advertisement
Table of contents
- 1 A Word to the Owner of the DFF3-UHD
- 1 Operational Cautions
- 1 Safety Instructions
- 2 Equipment List
- 2 Option
- 2 Installation
- 3 Wiring
- 6 Operation Check
- 6 Troubleshooting
- 7 Specifications
- 7 Transducer List
- 7 Licensed Software
- 9 PACKNG LIST
- 10 OUTLINE DRAWING
- 11 INTERCONNECTION DIAGRAM
- 12 Declaration of Conformity