PROFI-2510 / PROFI-2541
User Manual
Warranty
All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original purchaser.
Warning
ICP DAS assumes no liability for damages consequent to the use of this product. ICP DAS reserves the right to change this manual at any time without notice. The information furnished by ICP
DAS is believed to be accurate and reliable. However, no responsibility is assumed by ICP DAS for its use, or for any infringements of patents or other rights of third parties resulting from its use.
Copyright
Copyright 2012 by ICP DAS Co., LTD. All rights reserved worldwide.
Trademark
The names used for identification only may be registered trademarks of their respective companies.
Revision Note
Release
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------1
Table of Content
PROFIBUS Cable and Transmission Distance
................................................ 7
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------2
1. Introduction
1.1. Overview
PROFIBUS is an open, digital communication system with a wide range of applications, particularly in the fields of factory automation and process automation. PROFIBUS is suitable for both fast, time-critical applications and complex communication tasks. PROFIBUS-DP is a famous protocol that enables simple, fast, cyclic and deterministic process data exchange between
Master and assigned Slave.
The PROFI-2510 is a PROFIBUS repeater used to establish a physical coupling of two or more segments of a CAN bus system. According to the
PROFIBUS specification, up to 32 PROFIBUS devices are allowed per segment. Connecting via PROFI-2510, the division of a PROFIBUS system into several subsystems increases the maximum number of bus nodes.
The PROFI-2541 is a PROFIBUS to Fiber Converter and it is the economic solution for applications which require protecting the data transmission from electrical exposure, surges, lightning or chemical corrosion.
1.2. Product Information
Type
Repeater
Model Description
Converter
PROFI-2541 PROFIBUS to Fiber Converter(ST Type)
PROFI-2541-SC PROFIBUS to Fiber Converter(SC Type)
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------3
1.3. Appearance
PROFI-2510 PROFI-2541(SC)
1.4. Features
PROFI-2510
Supports Transmission Rate
(Kbps)
Transmission Rate Setting
Indicators
ESD Protection
Network Isolation Protection
DC Isolation Protection
PROFI-2541/ PROFI-2541-SC
9.6, 19.2, 45.45, 93.75, 187.5, 500,
1500, 3000, 6000, 12000 detected automatically
PWR LED, DP1 LED and DP2 LED
4kV class A
High Speed iCoupler
3000VDC on PROFIBUS side
Supports Transmission Rate
(Kbps)
9.6, 19.2, 45.45, 93.75, 187.5, 500,
1500, 3000
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------4
Transmission Rate Setting
Indicators
Fiber Wave Length
Fiber Type
Network Isolation Protection
DC Isolation Protection detected automatically
PWR LED, TxD LED and RxD LED
850 nm
ST / SC(Multi-Mode)
High Speed iCoupler
3000VDC on PROFIBUS side
1.5. Specifications
PROFI-2510
PROFIBUS Interface 9-pin D-Sub(Female)
PROFIBUS Transceiver ADI ADM2486 iCoupler Isolated transceiver
Transmission Rate
Power Requirement
Up to 12Mbps
10V ~ 30V
Power Consumption
Operating Temp.
Storage Temp.
Humidity
Dimensions
1W
-25 ~ +75 ℃
-30 ~ +85 ℃
5% ~ 95%(Non Condensing)
33 mm x 126.8 mm x 93.4 mm (W x L x H)
PROFI-2541/ PROFI-2541-SC
PROFIBUS Interface 9-pin D-Sub(Female)
PROFIBUS Transceiver ADI ADM2486 iCoupler Isolated transceiver
Transmission Rate
Power Requirement
Connector
Wave Length
Fiber cable
Up to 3Mbps
10V ~ 30V
ST / SC(Multi-Mode)
850 nm
62.5 / 125 μm
Propagation Delay
Transmission Distance
Operating Temp.
Storage Temp.
Humidity
Dimensions
125ns max (125ns delay shortens bus line length by ~ 25 m)
1.4 km max (in 62.5/125 μm fiber cable)
-25 ~ +75 ℃
-30 ~ +85 ℃
5% ~ 95%(Non Condensing)
33 mm x 126.8 mm x 104.5 mm (W x L x H)
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------5
2. Hardware
2.1. Bus Wiring
In order to minimize the reflection effect of the signal transmission,
PROFIBUS device has to fit with an active terminal resistor at both first node and last node, as shown below
However, the number of station in PROFIBUS network is also restricted.
According to PROFIBUS specification, it is up to 32 stations connected in a
PROFIBUS segment. If more than 32 stations are connected, the PROFIBUS repeater must be used to link the individual bus segments.
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------6
2.2. PROFIBUS Cable and Transmission Distance
The PROFIBUS cable with following properties has different transmission distance with respect to different transmission rate, shown in the following table
1. Impedance :135~165Ω
2. Capacity : lower than 30 pF/m
3. Loop resistance : lower than 110Ω/Km
4. Wire diameter : larger than 0.65mm
5. Core cross-section : larger than 0.34mm
2
Transmission Rate(Kbps) Transmission Distance per Segment (meter)
9.6, 19.2, 45.45, 93.75 1200
187.5 1000
500 400
1500 200
3000, 6000, 12000 100
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------7
2.3. Status Indicator
PROFI-2510 PROFI-2541(SC)
It provides three status indicator, In PROFI-2510, they are PWR LED
(red),DP1 LED(green) and DP2 LED (green). In PROFI-2541(SC), they are
PWR LED (red), TxD LED(green) and RxD LED (green). When the power is supplied to module, PWR LED will turn on; Transmitting/receiving one data to/from fiber cable will flash the DP1/DP2/TxD/RxD LED once. The
DP1/DP2/TxD/RxD LED may always be turned on if there are a lot of datas transmitted on fiber cable.
PROFI-2510 PROFI-2541(SC)
PWR Led (Red)
ON Module active
OFF Module inactive
PWR Led (Red)
ON
OFF
Module active
Module inactive
DP1 Led (Green)
Flashing Data transmitting
TxD Led (Green)
Flashing Data transmitting
OFF No data transmitting OFF
DP2 Led (Green)
No data transmitting
RxD Led (Green)
Flashing Data transmitting
OFF No data transmitting
Flashing Data transmitting
OFF No data transmitting
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------8
2.4. Connector
The connector of PROFI-2510 / PROFI-2541(SC) is shown below
Pin No. Signal Meaning
3 B-Line Receive/Transmit data - plus
4 CNTR-P Repeater control signal, RTS signal
5
6
GND
VP
Power ground of active terminator
Power 5 volt of active terminator
8 A-Line Receive/Transmit data - minus
Note: The connector of PROFI-2510 / PROFI-2541(SC) has no terminators; users must use the connector with the terminator inside. The power of the terminator will provide by terminal device.
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------9
2.5. Baud rate support
PROFI-2510 / PROFI-2541(SC) has a functionality of auto- detection for baud rates, users don’t need to set the baud rate manually.
PROFI-2510 supports the entire baud rates of PROFIBUS. They are
9.6Kbps, 19.2Kbps, 45.45Kbps, 187.5Kbps, 500Kbps, 1.5Mbps, 3Mbps,
6Mbps, and 12Mbps.
PROFI-2541(SC) supports the entire baud rates of PROFIBUS. They are
9.6Kbps, 19.2Kbps, 45.45Kbps, 187.5Kbps, 500Kbps, 1.5Mbps, and 3Mbps.
Note: Many baud rates only are supported by the particular cable or speed.
For the detail, please refer to the above section “PROFIBUS Cable and
Transmission Distance”
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------10
2.6. Wire Connection
PROFI-2510
If PROFI-2510 is a end device of PROFIBUS segment 1 and PROFIBUS segment 2. The terminal resistor of segment 1 is ON. The terminal resistor of segment 2 is ON.
If PROFI-2510 is an intermediary device of PROFIBUS segment 1. The terminal resistor of segment 1 is OFF.
PROFI-2541(SC)
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------11
Appendix A. Dimensions
PROFI-2510
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------12
PROFI-2541
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------13
PROFI-2541-SC
PROFI-2510 / PROFI-2541 User Manual (Nov/2012) -------------14