Schneider Electric TSXP5730, Processor Unit User Guide
Schneider Electric TSXP5730, Processor Unit
The Schneider Electric TSXP5730, Processor Unit is a powerful and versatile device that can be used in a wide variety of industrial applications. With its 1024 discrete I/O channels, 6 application-specific module slots, and 2 FIPWAY network connections, the TSXP5730 can be used to control a wide range of devices and systems.
The TSXP5730 also features a variety of built-in functions, including a real-time clock, a watchdog timer, and a power-fail interrupt. These functions make the TSXP5730 ideal for use in applications where reliability and uptime are critical.
تبلیغات
تبلیغات
TSX Premium
TSX P 57 30
Processor Unit
User's Guide
Contents
Chapitre
1 General presentation
Using a TSX P 57 30 with PL7 Junior V1.8
2
3
4
5
TSX P 57 30
3.1
General characteristics
3.2
Configuration
FIPWAY support on SCY
4.1
Setup
4.2
Configuration
4.3
Restrictions
Common word syntax
6
7
Configuration of Bridge services
Compatibility
Page
3
3
5
5
5
6
6
4
4
5
6
7
___________________________________________________________________________
1
ENGLISH
TSX DM 57E
TLX DR PL7 13E
TLX DM PL7J 13E
TLX DS 57 PL7 13E
For more information on the installation of TSX
Premium PLCs, please consult the following manuals :
TSX Premium. PLCs TSX 57
PL7 Micro/Junior
User’s Manual
Languages Reference Manual
PL7 Junior
PL7 Junior
Operating Modes Manual
Application specific Functions
TSX PREMIUM
___________________________________________________________________________
2
TSX 57 User's Guide
1 General presentation
This manual describes the use of the TSX P 57 30 processor V2
.•
.
This processor is identical to the TSX P 57 20 processor except for the two FIPWAY connections (one on the processor unit and one on a SCY module).
To run TSX P 57 30 under PL7 Junior V1.8 first install the attached disk.
This manual only describes functions specific to the TSX P 57 30. For all other functions, refer to the TSX DM 57 E manual.
Before starting up, check that your products are up to date (see 6. Compatibility).
2 Using a TSX P 57 30 with PL7 Junior V1.8
A disk labelled TSX PREMIUM, ”TSX 57 30 CATALOG” is provided to allow the use of the TSX P 57 30 with PL7 Junior V1.8.
Important :
This disk should be used exclusively with PL7 Junior V1.8.
To install the disk :
1. Close all your applications including PL7 Junior.
2. Insert the disk in the disk drive.
3. In the program manager (Windows 3.1x) or the Start menu (Windows 95), select the
File/Execute...
menu.
4. Enter the A:\SETUP command line and validate with the OK button.
5. Follow the instructions displayed for PL7 Junior installation.
Notes :
• There is no registration card for this set of disks.
• The disk should be re-installed following each PL7 Junior installation.
___________________________________________________________________________
3
3 TSX P 57 30
3.1
General characteristics
Maximum configuration
Functions
Memory
(2)
Application structure
Execution time for
1 K instructions
System overhead
TSX P 57 30
No. of TSX RKY ••E racks (6/8/12 positions)
Maximum no. of module slots
Maximum no. of discrete I/O channels
Maximum no. of application-specific modules (1)
No. of integrated UNI-TELWAY connections
(terminal port)
No. of FIPWAY network connections (3)(4)
No. of FIPIO agent bus connections(4)
Realtime clock
Internal RAM (can be protected)
PCMCIA memory card
Max. memory size
Master task
Fast task
Event processing
Internal Ram
PCMCIA card
100% Boolean
100% numeric
65% Boolean/35% numeric
100% Boolean
65% Boolean/35% numeric cyclic operation periodic operation
8
96
1024
6
1
2
1
Yes
48 Kwords
32/64/128 Kwords
176 Kwords
1
1
64
(1 of which takes priority)
0.31 ms
0.44 ms
0.78 ms
0.47 ms
0.98 ms
Programming software
Programming languages
MAST task
FAST task
1.4 ms
1.2 ms
0.5 ms
PL7 Junior under
Windows
Ladder language,
Grafcet language,
Structured Text language, List language
(1) Counter (TSX CTY ••), axis control (TSX CAY ••), stepper control (TSX CFY ••), communication (TSX SCY 21600), weighing (TSX ISP Y100).
(2) Kwords = K16 (16 bit word)
(3) One connection on the processor unit and one on a SCY 21600 module
(4) Total number of connections (FIPIO and FIPWAY) limited to 2
___________________________________________________________________________
4
TSX 57 User's Guide
3.2
Configuration
When creating a new application, choose TSX 57 30 in the dialog box.
The FIPWAY configuration is exactly the same as for TSX 57 20 except that the common words network number has to be entered.
Important :
• There is no consistency check between the network number entered and the
TSX FPP 20 network number (set by switches).
• It is not possible to change the network number if common words are already used in the application.
To change the network number, place the instructions using the common words between comment brackets (* *) where possible, or use the PL7 Junior export/ import feature (export the modules where common words are used, delete them, change the network number in the configuration then change the common words address while importing the modules).
4 FIPWAY support on SCY
A FIPWAY connection can be made on a SCY controlled by a TSX P 57 30.
4.1
Setup
Use a TSX FPP 20 PCMCIA FIPWAY card. Refer to theTSX Premium User’s manual part D 3.3. for installation and connection.
4.2
Configuration
To configure the FIPWAY connection, double-click on the SCY module and select a TSX
FPP 20 PCMCIA card on channel 1.
The SCY FIPWAY configuration screen is a subset of the CPU FIPWAY configuration screen.
___________________________________________________________________________
5
4.3
Restrictions
The following restrictions apply to the SCY FIPWAY connection :
• Telegram function not supported
• No application download
• No consistency check between the network number entered and the TSX FPP 20 network number (set by switches)
The following restrictions apply to the dual FIPWAY configuration:
• No checking of CPU and SCY shared tables overlapping
• No automatic routing between networks
• There is no check that the SCY FIPWAY network number is different from the CPU
FIPWAY network number.
5 Common word syntax
The multi-network common word syntax is :
%NW {network no.station no.} word rank
Example :
%NW {1.2} 3 is word 3 of station 2 in network 1
6 Configuration of Bridge services
For each network connection point, the Bridge data contains the list of networks which can be accessed by this network. This is used to select the network module for accessing the target network from the rack.
A Bridge station can only manage 2 network modules.
A special screen is used to enter Bridge data for all the network modules of a station.
It can be accessed from FIPWAY configuration screens, using the Bridge button or selecting Bridge item in services menu.
___________________________________________________________________________
6
TSX 57 User's Guide
7 Compatibility
Use of the TSX 57 30 requires the following minimum versions :
Product Reference
SCY communication module TSX SCY 21600
PL7 Junior
Fipway PCMCIA board
TLXL FPL7J
••
TSX FPP 20
Minimum version
V1.4
V1.8
V1.3
___________________________________________________________________________
7
Schneider Automation Inc.
One High Street
North Andover, MA 01845
Tél.: (1) 508 794 0800
Fax : (1) 508 975 9010
Schneider Automation S.A.
245, route des Lucioles - BP 147
F-06903 Sophia Antipolis
Tél. : (33) (0)4 92 96 20 00
Fax : (33) (0)4 93 65 37 15
Schneider Automation GmbH
Steinheimer Straße 117
D-63500 Seligenstadt
Tél. : (49) 6182 81 2584
Fax : (49) 6182 81 2860
Printed In France October 1997 (827)
دانلود
تبلیغات