Bürkert Type2012 Operating Instructions Manual
Burkert Type2012 is a globe control valve that is pneumatically operated and has actuator sizes ranging from 40 mm to 125 mm and nominal diameters from DN10 to DN65. It is designed for use with liquid and gaseous media and can be used in various applications such as controlling the flow of water, alcohol, oil, fuel, hydraulic fluid, saline solution, lye, organic solvent, and steam. The valve has screwed-in seats that can be changed if required, making it easy to maintain and repair.
Advertisement
Advertisement
Type 2012
Globe control valve, pneumatically operated
Actuator sizes 40 mm - 125 mm, Nominal diameter DN10 - 65
Kolbengesteuertes Geradsitzventil
Antriebsgrößen 40 mm - 125 mm, Nennweiten DN10 - 65
Vanne à siège droit commandée par piston
Tailles d'actionneur 40 mm - 125 mm, Diamètre nominal DN10 - 65
Operating Instructions
Bedienungsanleitung
Manuel d‘utilisation
We reserve the right to make technical changes without notice.
Technische Änderungen vorbehalten.
Sous réserve de modifications techniques.
© 2000 - 2017, Bürkert Werke GmbH & Co. KG
Operating Instructions 1705/20_EU-ML_00804072 / Original DE
Type 2012
1 Operating instructiOns ................................................................4
1.1 Symbols ....................................................................................... 4
1.2 Definition of term ....................................................................... 4
2 authOrized use ......................................................................................5
3 Basic safety instructiOns ..........................................................5
4 general infOrmatiOn ........................................................................6
4.1 Contact address ........................................................................ 6
4.2 Warranty ...................................................................................... 6
4.3 Information on the Internet ...................................................... 6
5 prOduct descriptiOn ........................................................................7
5.1 General description .................................................................. 7
6 structure and functiOn...............................................................7
6.1 Structure ...................................................................................... 7
6.2 Function ....................................................................................... 8
7 technical data ........................................................................................9
7.1 Conformity ................................................................................... 9
7.2 Standards .................................................................................... 9
7.3 Type label .................................................................................... 9
7.4 Operating conditions ..............................................................10
7.5 Control functions .....................................................................14
7.6 Mechanical data.......................................................................14
8 installatiOn ............................................................................................15
8.1 Safety instructions ...................................................................15
8.2 Before installation ....................................................................15
8.3 Installation .................................................................................16
8.4 Pneumatic connection ............................................................18
8.5 Removal .....................................................................................18
9 maintenance, cleaning ................................................................19
9.1 Safety instructions ...................................................................19
9.2 Maintenance work ...................................................................19
9.3 Replacing the valve seat ........................................................20
10 malfunctiOns ........................................................................................21
11 replacement parts ..........................................................................22
11.1 Replacement part sets ...........................................................22
11.2 Overview of spare parts .........................................................22
12 transpOrt, stOrage, dispOsal ..............................................23
english 3
Type 2012
OperatingInstructions
1 OperaTing insTrucTiOns
The operating instructions describes the entire life cycle of the device.
Keep these instructions in a location which is easily accessible to every user, and make these instructions available to every new owner of the device.
Warning!
the operating instructions contain important safety information!
Failure to observe these instructions may result in hazardous situations.
▶ The operating instructions must be read and understood.
Caution!
Warns of a possible danger!
▶ Failure to observe this warning may result in a moderate or minor injury.
note!
Warns of damage to property!
▶ Failure to observe the warning may result in damage to the device or the equipment.
Indicates important additional information, tips and recommendations.
1.1 symbols
Danger!
Warns of an immediate danger!
▶ Failure to observe the warning may result in a fatal or serious injury.
Warning!
Warns of a potentially dangerous situation!
▶ Failure to observe the warning may result in serious injuries or death.
Refers to information in these operating instructions or in other documentation.
▶ Designates an instruction to prevent risks.
→
Designates a procedure which you must carry out.
1.2 Definition of term
The term “device” used in these instructions always stands for the globe control valve Type 2012.
4 english
Type 2012
AuthorizedUse
2 auThOrizeD use
non-authorized use of the globe control valve type 2012 may be a hazard to people, nearby equipment and the environment.
▶ The device is designed for the controlled flow of liquid and gaseous media.
▶ In the potentially explosion-risk area the device may be used only according to the specification on the separate Ex type label. For use observe the additional information enclosed with the device together with safety instructions for the explosion-risk area.
▶ Devices without a separate Ex type label may not be used in a potentially explosive area.
▶ The admissible data, the operating conditions and conditions of use specified in the contract documents, operating instructions and on the type label are to be observed during use. These are described in the chapter entitled “Technical Data”.
▶ The device may be used only in conjunction with third-party devices and components recommended and authorized by Bürkert.
▶ Correct transportation, correct storage and installation and careful use and maintenance are essential for reliable and faultless operation.
▶ Use the device only as intended.
3 Basic safeTy insTrucTiOns
These safety instructions do not make allowance for any
• contingencies and events which may arise during the installation, operation and maintenance of the devices.
• local safety regulations, whereby the operator is responsible for their compliance, by the installation personnel too.
danger – high pressure.
▶ Before dismounting the lines and valves, turn off the pressure and vent the lines.
risk of electric shock.
▶ Before reaching into the device, switch off the power supply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for electrical equipment.
risk of injury when opening the actuator.
The actuator contains a tensioned spring. If the actuator is opened, there is a risk of injury from the spring jumping out!
▶ The actuator must not be opened.
risk of injury from moving parts in the device.
▶ Do not reach into openings.
english 5
6 risk of burns.
The surface of the device may become hot during long-term operation.
▶ Do not touch the device with bare hands.
general hazardous situations.
To prevent injury, ensure:
▶ That the system cannot be activated unintentionally.
▶ Installation and repair work may be carried out by authorized technicians only and with the appropriate tools.
▶ After an interruption in the power supply or pneumatic supply, ensure that the process is restarted in a defined or controlled manner.
▶ The device may be operated only when in perfect condition and in consideration of the operating instructions.
▶ The general rules of technology apply to application planning and operation of the device.
To prevent damage to property of the device, ensure:
▶ Supply the media connections only with those media which are specified as flow media in the chapter entitled “7 Technical Data”.
▶ Do not put any loads on the valve (e.g. by placing objects on it or standing on it).
▶ Do not make any external modifications to the valves.
▶ Do not paint the body parts or screws.
Type 2012
GeneralInformation
4 general infOrmaTiOn
4.1 contact address
germany
Bürkert Fluid Control Systems
Sales Center
Christian-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: [email protected]
international
Contact addresses are found on the final pages of the printed operating manual.
You can also find information on the Internet under: www.burkert.com
4.2 Warranty
The warranty is only valid if the device is used as authorized in accordance with the specified application conditions.
4.3 information on the internet
The operating instructions and data sheets for Type 2012 can be found on the Internet at: www.burkert.com
english
Type 2012
ProductDescription
5 prODucT DescripTiOn
5.1 general description
The 2/2-way globe control valve Type 2012 is suitable for liquid and gaseous media. It uses neutral gases or air (control media) to control the flow of water, alcohol, oil, fuel, hydraulic fluid, saline solution, lye, organic solvent and steam (flow media).
A particular feature of the globe control valves are screwed in seats which can be changed if required.
5.1.1 restrictions
Warning!
risk of injury from water hammer!
A water hammer could crack the lines and device. Due to the risk of water hammer , valves with a flow direction above seat must not be used for liquid media .
▶ Consider the type of flow direction and the type of medium for operation of the device.
6 sTrucTure anD funcTiOn
6.1 structure
The globe control valve consists of a pneumatically actuated piston actuator and a 2/2-way globe control valve body.
The actuator is manufactured from PA or, for special operating conditions, from PPS. The self-adjusting packing gland ensures a high degree of tightness. The valve body, made of stainless steel, enables high flow values.
Transparent cap with position indicator
Actuator cover
Pilot air ports
Actuator body
Interface actuator / body with flats
Globe valve body
Port connection
Fig. 1: Globe control valve Type 2012, Structure and description english 7
6.2 function
Depending on the version, the seat of the valve is closed with or against the medium flow.
Spring force (CFA) or pneumatic pilot pressure (CFB and CFI) generates the closing force on the swivel plate. The force is transferred via a spindle which is connected to the actuator piston.
6.2.1 control functions (cf)
Warning!
for control function i – danger if pilot pressure fails.
For control function I control and resetting occur pneumatically. If the pressure fails, no defined position is reached.
▶ To ensure a controlled restart, first pressurise the device with pilot pressure, then switch on the medium.
A a
(cfa)
Normally closed by spring action
P
B
B
(cfB)
Normally open by spring action
P
A i
(cfi)
P
Actuating function via reciprocal pressurisation
8 english
Type 2012
StructureandFunction
6.2.2 flow direction below seat
Depending on the version, the valve is closed against the medium flow with spring force (control function A, CFA) or with pilot pressure
(control function B or I, CFB or CFI).
As the medium pressure is under the swivel plate, this pressure contributes to the opening of the valve.
Warning!
medium may be discharged if minimum pilot pressure is too low or medium pressure too high.
If the minimum pilot pressure is too low for CFB and CFI or the permitted medium pressure is exceeded, leaks may occur.
▶ Observe minimum pilot pressure.
▶ Do not exceed medium pressure.
▶ See chapter entitled “7.4.2 Pressure ranges”.
CFA CFB /
CFI
Fig. 2: Flow direction below seat (closing against medium)
Type 2012
TechnicalData
6.2.3 flow direction above seat
The valve is closed by spring force (control function A, CFA) with the medium flow. As the medium pressure is over the swivel plate, it supports the closing process of the valve and also contributes to the sealing of the valve seat. The valve is opened by the pilot pressure.
Warning!
risk of injury from water hammer.
A water hammer could crack the lines and device. Due to the risk of water hammer , valves with a flow direction above seat must not be used for liquid media .
▶ Consider the type of flow direction and the type of medium for operation of the device.
To ensure complete opening, the minimum pilot pressure must be applied.
Fig. 3: Flow direction above seat (closing with medium)
7 Technical DaTa
7.1 conformity
The globe control valve Type 2012 conforms with the EU Directives according to the EU Declaration of Conformity.
7.2 standards
The applied standards, which verify conformity with the EU Directives, can be found on the EU-Type Examination Certificate and / or the EU
Declaration of Conformity.
7.3 Type label
Orifice
Control function
Type
Seal material
2012 A 32,0 PTFE VA
G 1/4 P med 15 bar
Pilot 5 - 10 bar
Body material
00182076
W1X LU
Id. Number
Operating pressure
Connection type, Nominal pressure
Fig. 4: Description of type label english 9
7.4 Operating conditions
7.4.1 Temperature ranges actuator size
[mm]
40 - 63
80 - 125 actuator material
PA
PA
40 - 80 PPS
100 - 125 PPS temperature ranges medium (for ptfe seal) environment 1)
–10 ... see “Fig. 5”
–10 ... +180 °C
–10 ... see “Fig. 5”
–10 ... +60 °C
–10 ... +180 °C +5 ... +140 °C
–10 ... +180 °C +5 ... +90 °C, briefly up to max. +140 °C
Tab. 1: Temperature ranges
1)
If a pilot valve is used, the max. ambient temperature is + 55 °C.
Ambient temperature
[°C]
70
60
50
∅
50
∅
63
40
∅
40
30
20
100 120 140 160 180 200
Medium temperature [°C]
Fig. 5: Temperature range of the maximum medium and ambient temperature for PA actuators
10 english
Type 2012
TechnicalData
7.4.2 pressure ranges actuator material
PA actuator size
[mm]
40 - 100
125
40 - 100
PPS
125
Tab. 2: Maximum pilot pressure max. pilot pressure
[bar]
10
7
10
7 medium and pilot pressure for control function a, flow direction below the seat (standard) maximum medium pressure / minimum pilot pressure
Ori- fice
40 50
10/15 15/4.0 16/3.9
actuator size ø [mm]
63 80 100 125
20 6.5/4.0 11/3.9
16/4.5
25 5.2/3.9 11/4.5
16/5.0
32
40
50
65
6/4.5
4/4.5
14/5.0
16/4.4
9/5.0
12.5/4.4
16/3.2
2.5/4.5 6/5.0
7.2/4.4
Tab. 3: Medium and pilot pressure for CFA, standard
10/3.2
12/5.6
Type 2012
TechnicalData required minimum pilot pressure depending on medium pressure.
The following graphs illustrate the required minimum pilot pressure depending on the medium pressure for control functions A, B and I.
control function a, flow direction above seat
Pilot pressure [bar]
Fig. 7: Pressure graph, actuator ø 50 mm, control function A, flow direction above seat
Pilot pressure [bar]
Fig. 6: Pressure graph, actuator ø 40 mm, control function A, flow direction above seat
Pilot pressure [bar]
Fig. 8: Pressure graph, actuator ø 63 mm, control function A, flow direction above seat english 11
Type 2012
TechnicalData
Pilot pressure [bar]
Fig. 9: Pressure graph, actuator ø 80 mm, control function A, flow direction above seat
*
Pilot pressure [bar]
Fig. 11: Pressure graph, actuator ø 125 mm, control function A, flow direction above seat
* Medium pressure max. 15 bar acc. to Pressure Equipment Directive
2014/68/EU for compressible fluids in Group 1 (hazardous gases and vapors in accordance with Article 4 paragraph (1) c) i) first dash).
Pilot pressure [bar]
Fig. 10: Pressure graph, actuator ø 100 mm, control function A, flow direction above seat
12 english
Type 2012
TechnicalData control functions B and i, flow direction below seat
Pilot pressure [bar]
Fig. 12: Pressure graph, actuator ø 40 mm, control functions B and I, flow direction below seat
Pilot pressure [bar]
Fig. 14: Pressure graph, actuator ø 63 mm, control functions B and I, flow direction below seat
Pilot pressure [bar]
Fig. 13: Pressure graph, actuator ø 50 mm, control functions B and I, flow direction below seat
Pilot pressure [bar]
Fig. 15: Pressure graph, actuator ø 80 mm, control functions B and I, flow direction below seat english 13
*
Pilot pressure [bar]
Fig. 16: Pressure graph, actuator ø 100 mm, control functions B and I, flow direction below seat
*
Type 2012
TechnicalData
7.4.3 media
Control medium neutral gases, air
Flow medium water, alcohol, fuel, hydraulic liquids, saline solutions, lye, organic solvents
7.5 control functions
Control function A Normally closed by spring action
Control function B Normally open by spring action
Control function I Actuating function via reciprocal pressurization
7.6 mechanical data
materials
Valve body Stainless steel 316L
Actuator PA, PPS
Seal materials PTFE
(NBR, FKM and EPDM on request)
Packing gland PTFE (carbon-filled)
Pilot pressure [bar]
Fig. 17: Pressure graph, actuator ø 125 mm, control functions B and I, flow direction below seat
14 english
Type 2012
Installation
8 insTallaTiOn
8.1 safety instructions
Danger!
risk of injury from high pressure.
▶ Before loosening the lines and valves, turn off the pressure and vent the lines.
Warning!
risk of injury from improper installation.
▶ Installation may be carried out by authorized technicians only and with the appropriate tools!
risk of injury from unintentional activation of the system and an uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.
for control function i – danger if pilot pressure fails.
For control function I control and resetting occur pneumatically. If the pressure fails, no defined position is reached.
▶ To ensure a controlled restart, first pressurize the device with pilot pressure, then switch on the medium.
risk of injury from moving parts in the device.
▶ Do not reach into openings.
8.2 Before installation
Installation position: any, preferably with the actuator face up.
→
Before connecting the valve, ensure the lines are flush.
→
Observe direction of flow.
8.2.1 preparatory work
→
Clean pipelines (sealing material, swarf, etc.).
devices with welded body
Remove the actuator from the valve body:
→
Clamp the valve body in a holding device.
note! damage to the seat seal or the seat contour!
▶ When removing the actuator, ensure that the valve is in open position.
→
Control function A: pressurize the lower control air connection with compressed air
(6 bar): valve opens.
→
Using a suitable open-end wrench, place the wrench flat on the tube.
→
Unscrew the actuator from the valve body.
english 15
Type 2012
Installation
8.3 installation
Warning!
risk of injury from improper assembly.
Assembly with unsuitable tools or non-observance of the tightening torque is dangerous as the device may be damaged.
▶ For installation use an open-end wrench, never a pipe wrench.
▶ Observe the tightening torque (see “Tab. 4: Tightening torques of valve body / nipples”).
dirt trap for devices with authorization in accordance with din en 161
In accordance with DIN EN 161 “Automatic shut-off valves for gas burners and gas appliances” a dirt trap must be connected upstream of the valve and prevent the insertion of a 1 mm plug gauge.
→
If the authorisation also applies to stainless steel bodies, the same type of dirt trap must be attached in front of the globe control valve.
8.3.1 installation of the valve body
Welded bodies
→
Weld valve body in pipeline system.
Other body versions
→
Connect body to pipeline.
8.3.2 install actuator (welded body)
Seal
Fig. 18: Seal
→
Check the seal and if required, replace it.
Warning!
danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen applications there is a risk of an explosion!
▶ In specific applications, e.g. oxygen or analysis applications, use appropriately authorised lubricants only.
→
Grease nipple thread before re-installing the actuator (e.g. with
Klüber paste UH1 96-402 from Klüber).
note! damage to the seat seal or the seat contour.
▶ When installing the actuator, ensure that the valve is in open position.
→
Control function A:
Pressurize lower control air connection with compressed air
(6 bar) so that the swivel plate is lifted off the valve seat and is not damaged when screwed in.
16 english
Type 2012
Installation
→
Screw actuator into the valve body.
tightening torques of valve body / nipples nominal diameter
15
20
25 tightening torque (nm)
45 ± 3
50 ± 3
60 ± 3
32
40
65 ± 3
65 ± 3
50 70 ± 3
65 70 ± 3
Tab. 4: Tightening torques of valve body / nipples
8.3.3 rotating the actuator
The position of the connections can be aligned steplessly by rotating the actuator through 360°.
note! damage to the seat seal or the seat contour.
▶ When rotating the actuator, ensure that the valve is in open position.
→
Clamp the valve body in a holding device
(applies only to valves which have not yet been installed).
→
Control function A: pressurize the lower control air connection with compressed air (6 bar): valve opens.
→
Counter on the flats of the nipple with a suitable open-end wrench.
→
Place suitable open-end wrench on the hexagon of the actuator.
Warning!
risk of injury from discharge of medium and pressure.
If the direction of rotation is wrong, the body interface may become detached.
▶ Rotate the actuator module in the specified direction only (see
“Fig. 19”).
→
By turning the open-end wrench clockwise (viewed from above), move the actuator into the required position.
Fig. 19: Turning with open-end wrench
Open-end wrench english 17
8.4 pneumatic connection
Danger!
danger – high pressure in the equipment.
▶ Before loosening the lines and valves, turn off the pressure and vent the lines.
Warning!
risk of injury from unsuitable connection hoses.
Hoses which cannot withstand the pressure and temperature range may result in hazardous situations.
▶ Use only hoses which are authorised for the indicated pressure and temperature range.
▶ Observe the data sheet specifications from the hose manufacturers.
for control function i – danger if pilot pressure fails.
For control function I control and resetting occur pneumatically. If the pressure fails, no defined position is reached.
▶ To ensure a controlled restart, first pressurize the device with pilot pressure, then switch on the medium.
If the position of the pilot air ports for installation of the hoses is unfavorable, these can be aligned steplessly by rotating the actuator through 360°.
control function a
→
Connect the control medium to the lower control air connection of the actuator.
18 english
Type 2012
Installation control function B
→
Connect the control medium to the upper control air connection of the actuator.
control function i
→
Connect the control medium to the lower and upper control air connection of the actuator.
If used in an aggressive environment, we recommend conveying all free pneumatic connections into a neutral atmosphere with the aid of a pneumatic hose.
control air hose:
6/4 mm or 1/4” control air hoses can be used.
8.5 removal
Danger!
risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to the sudden release of pressure or discharge of medium.
▶ Before removing a device, switch off the pressure and vent the lines.
→
Loosen the pneumatic connection.
→
Remove the device.
Type 2012
Maintenance,Cleaning
9 mainTenance, cleaning
9.1 safety instructions
Danger!
danger – high pressure in the equipment.
▶ Before loosening the lines and valves, turn off the pressure and vent the lines.
risk of injury due to electrical shock.
▶ Before reaching into the system, switch off the power supply and secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations for electrical equipment!
Warning!
risk of injury from improper maintenance.
▶ Maintenance may be performed by authorised technicians only!
▶ To screw on or unscrew valve body or actuator, use an open-end wrench, never a pipe wrench, and observe tightening torques.
risk of injury from unintentional activation of the system and an uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following maintenance, ensure a controlled restart.
Warning!
for control function i – danger if pilot pressure fails.
For control function I control and resetting occur pneumatically.
If the pressure fails, no defined position is reached.
▶ To ensure a controlled restart, first pressurize the device with pilot pressure, then switch on the medium.
risk of injury from moving parts in the device.
▶ Do not reach into openings.
9.2 maintenance work
actuator:
The actuator of the globe control valve is maintenance-free provided it is used according to these operating instructions.
Wearing parts of the globe control valve:
Parts which are subject to natural wear:
• Valve seat,
• Seals.
→
If leaks occur, replace the particular wearing part with an appropriate spare part.
Visual inspection:
Perform regular visual inspections according to the application conditions:
→
Check media connections for leaks.
→
Check release bore on the tube for leaks.
english 19
Release bore
Fig. 20: Release bore
9.2.1 cleaning
Commercially available cleaning agents can be used to clean the outside.
note! avoid causing damage with cleaning agents.
▶ Before cleaning, check that the cleaning agents are compatible with the body materials and seals.
9.3 replacing the valve seat
remove the actuator from the valve body
→
Clamp the valve body in a holding device.
note! damage to the seat seal or the seat contour.
▶ When removing the actuator, ensure that the valve is in open position.
20 english
Type 2012
Maintenance,Cleaning
→
Control function A: pressurize the lower control air connection with compressed air (6 bar): valve opens.
→
Using a suitable open-end wrench, place the wrench flat on the tube.
→
Unscrew the actuator from the valve body.
replacing valve seat
→
Unscrew old valve seat using the installation tool and open-end wrench.
→
Clean thread and sealing surface in the body using compressed air.
→
Select tool insert and screw into the installation tool.
Installation tool
Tool insert
(according to nominal width of seat)
Valve seat
Fig. 21: Replacing the valve seat
Type 2012
Malfunctions
→
Attach new valve seat to the installation tool.
→
Grease thread with a lubricant (e.g. Klüber paste UH1 96-402).
→
Place attached valve seat on the body thread and screw on by hand.
→
Using a torque wrench, tighten to the specified tightening torque
(see “Tab. 5”).
tightening torque for installation of seat screw connection seat Body
DN 4-15 DN 15
DN 20 DN 20
DN 25
DN 32
DN 25
DN 32 tightening torques uncoated seats coated seats
25
35
50
80
20
28
40
65
DN 40
DN 50
DN 65
DN 80
DN 40
DN 50
DN 65
DN 80
100
120
150
180
85
120
150
180
DN 100 DN 100 220 220
Tab. 5: Tightening torque for installation of seat tolerance
+8
+8
+10
+10
+10
+3
+3
+5
+5
10 malfuncTiOns
malfunction
Actuator does not switch reason
Pilot air port interchanged
Pilot pressure too low
Medium pressure too high
Flow direction reversed remedial action
→
Connect lower (CFA,
CFI) or upper (CFB,
CFI) control air connection
→
Observe pressure specifications on the type label
→
Observe direction arrow on the body
→
Installing dirt trap Valve is not sealed
Dirt between seal and valve seat
Seat seal worn
Flow direction reversed
Medium pressure too high
Pilot pressure too low
Valve is leaking on the release bore
Packing gland worn
Tab. 6: Malfunctions
→
→
Installing new seat seal
Observe direction arrow on the type label
→
Observe pressure specifications on the type label
→
Renew packing gland or replace actuator english 21
11 replacemenT parTs
Caution!
risk of injury and/or damage by the use of incorrect parts.
Incorrect accessories and unsuitable replacement parts may cause injuries and damage the device and the surrounding area.
▶ Use only original accessories and original replacement parts from
Bürkert.
11.1 replacement part sets
The following spare part sets are available for the globe control valve
Type 2012:
• Seal set,
• Valve set,
• Valve fittings (valve set + seat).
Type 2012
Replacementparts
11.2 Overview of spare parts
Seal set 1
2 Valve set
The order numbers of the spare parts and the installation instructions can be found in the spare parts operating instructions on our website: www.burkert.com
→ Type 2012.
Fittings set
(valve set + seat)
3
Fig. 22: Overview of spare parts
22 english
Type 2012
Transport,Storage,Disposal
12 TranspOrT, sTOrage,
DispOsal
note! transport damages.
Inadequately protected equipment may be damaged during transport.
• During transportation protect the device against wet and dirt in shock-resistant packaging.
• Avoid exceeding or dropping below the permitted storage temperature.
incorrect storage may damage the device.
• Store the device in a dry and dust-free location!
• Storage temperature -20 – +65 °C.
damage to the environment caused by device components contaminated with media.
• Dispose of the device and packaging in an environmentally friendly manner.
• Observe applicable regulations on disposal and the environment.
note:
Observe national waste disposal regulations.
english 23
24 english
Type 2012
www.burkert.com
Download
Advertisement