AWS AMW-1000 User manual
AWS AMW-500i is a precise and easy-to-use digital tabletop scale, perfect for various weighing tasks. With a capacity of 1000g and a resolution of 0.1g, it provides accurate measurements for both small and large items. The backlit LCD display ensures clear visibility, even in low-light conditions. The scale offers multiple weighing units, including grams, ounces, troy ounces, and pennyweights, allowing you to choose the most suitable unit for your specific needs.
Advertisement
Advertisement
American Weigh Scales, Inc.
AMW-BENCH
D i g i t a l T a b l e t o p S c a l e
ON/O
FF g
Hold
Mode
Tare
AMW-500i
AMW-1000
User Manual
AMW-BENCH Manual
Thank you for purchasing the American Weigh AMW-
BENCH series digital tabletop scale. Please read all operating instructions carefully before use. This electronic scale is a precision instrument. With normal care and proper treatment, it will provide years of reliable service.
Never load the scale with more than the maximum capacity. Overloading will permanently damage it!
Avoid any exposure to extreme heat or cold. Your scale works better when operated at normal room temperature. Always allow the scale to acclimate to normal room temperature for at least one hour before use. Give your scale sufficient warm up time. Usually
30-60 seconds before calibration to give the internal components a chance to stabilize.
Keep your scale in a clean environment. Dust, dirt, moisture, vibration, air currents and a close distance to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale.
Handle with care. Gently apply all items to be weighed onto tray top. Although this scale is designed to be quite durable, try to avoid rough treatment as this may permanently damage the internal sensor.
Avoid shaking, dropping or otherwise shocking the scale. This is a precision instrument and must be handled with extreme care.
Only operate the scale on a stable, vibration free
surface.
I. OPERATION
Place Scale on a horizontal flat surface.
1. Press [ON/OFF] key.
2. Wait until "0.0” is displayed.
3. Put the object(s) on the weighing platform.
4. Using the [MODE] key, you can switch between the weighing units.
II. TARE WEIGHING
1. Turn on scale as described above.
2. Place the "tare item" on the platform.
3. Press [TARE] and wait until "0.0" is displayed.
4. Add the "net-weight-item".
III. CALIBRATION
Calibration is NOT required before first use. Only calibrate if scale is not weighing properly.
**Make sure you use the correct calibration weight for your scale or the calibration will not be accurate**
AMW-500i: 500g calibration weight
AMW-100: 2 (two) 500g calibration weights a. AMW-500i Calibration Procedures
1. Press “On/Off” key to turn off the scale.
2. Press and hold the “On/Off” and “Mode” keys at the same time until the display shows a random number. Release both keys now.
3. Press the “On/Off” key once.
4. When the display reads “500 g”, place your 500g calibration weight on the scale.
5. Press “On/Off” again. The display should read “PASS”.
You can now turn off your scale.
b. AMW-1000 Calibration Procedures
1. With the scale OFF, press and hold the “Tare” key until the display shows a random number. Release the “Tare” key now.
3. Press the “Tare” key once. The scale will show “0.0”
4. Place your 500g calibration weight on the scale. The display will show a random number.
5. Press “Tare” again. The display will show “500 g”
6. Place another 500g calibration weigh on the scale to make a total of 1000 grams on the scale. The display will show a random number.
6. Press “Tare” once more, the display should read “1000.0”.
You can now turn off your scale by holding the “Tare” key.
Please check the availability of weights with your scale supplier.
IV. TROUBLESHOOTING
The primary reasons for inaccuracy or malfunction are low batteries, incorrect calibration, overload or operating on an unstable surface. Please keep this in mind and maintain and operate your scale properly.
This scale is a precise instrument and must be handled with the utmost care and caution.
[Display] Elimination of errors
Nothing, Battery-Symbol, [lo] or [88888]
Change the batteries.
[OL-d] The scale has been overloaded. You can try recalibrating the scale as shown above.
[EEEEE] You are overloading the scale. Remove the excessive load immediately!
[UNST] Use the scale in a more stable position