Gefran TK DataSheet
விளம்பரம்
விளம்பரம்
TK
PRESSURE TRANSMITTER
Main Features
• Ranges: from 0...3 to 0...1000 bar
and ranges from -1...+1 to -1...+10 bar
• Output signal 4...20mA 2-wires / 0.1...5.1Vdc /
0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...10Vdc
• Protection rating: IP65/IP67
• Wetted parts AISI 430F and 17-4PH
• Available with a variety of process connections, both standard and custom
TK transmitters are based on the extensimetric thick film measuring principle. Thanks to highly stable electronic components, these transmitters can be used in applications requiring long-distance signal transmission or in smart control systems. TK pressure transmitters are designed mainly to measure pressure in oil, air, and hydraulic circuits. They can also be used in the technical and process measurement application as well as for compressors, presses and mobile hydraulic.
TECHNICAL DATA
Output signal VOLTAGE CURRENT
Accuracy (
Overpressure (without degrading performance) (
Pressure containment (burst test) (
1
Measurement range
Resolution
2)
3
)
)
Pressure Media
Body materials
Power supply B/M/P/R
H ± 0.25% FS typical (± 0.3% FS max)
M ± 0.5% FS typical (± 0.6% FS max) from 0...3 bar to 0...1000 bar; from -1...+1 bar to -1...+10bar
10...30Vdc
C/N/Q 15...30Vdc
Infinite
See table
See table
Fluid compatible with Inox 17-4 PH/AISI 430F
Inox AISI 304
10...30Vdc
Supply Sensitivity
Output noise (RMS 10-400Hz)
Insulation resistance
Zero output signal
< 0.05% FS
> 1000 MΩ @ 50Vdc
B, C, M, N, P, Q, R
< 0.0015% FS/V
Full scale output signal
Max current absorption
Max allowed load
Long term stability
B, C, M, N, P, Q, R
13mA
1mA
< 0.2% FS/per year
4mA (E)
20mA (E)
32mA
See diagram
Operating temperature range (process)
Compensated temperature range
Storage temperature range
Temperature effects over compensated range (zero-span)
Response time (10...90%FS)
Start-up time
Mounting position effects
Humidity
Weight
Mechanical shock
Vibrations
Ingress protection
Output short circuit and reverse polarity protection
-40...+105°C (-40...+221°F)
-10...+85°C (+14...+185°F)
-40...+125°C (-40...+257°F)
± 0.012% FS/°C typical (± 0.02% FS/°C max.)
< 1 msec.
< 500 msec.
Negligible
Up to 100%RH non-condensing
110 gr. nominal
100g/11ms according to IEC 60068-2-27
20g max at 10-2000Hz according to IEC 60068-2-6 sealed to IP65/IP66/IP67
YES
FS = Full Scale
1 BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability (acc. to IEC 62828-2)
2 tested for more than 1000 strokes with single duration < 2msec.
3 tested for more than 100 strokes with single duration < 2msec.
MEASUR. RANGE (BAR) -1/+1 -1/+2 -1/+3 -1/+5 -1/+10 3 4 5 6 7 10 16 20 25 30 40 50 60 100 160 200 250 350 400 500 600 700 1000
Overpressure
Burst test
2
12
4
12
6
12
10
20
20
40
6 8 10 12 14 20 32 40 50 60 80 100 120 200 320 400 500 700 800 1000 1200 1200 1200
12 16 20 24 28 40 64 80 100 120 160 200 240 400 640 800 1000 1200 1200 1200 1500 1500 1500
INSTALLATION DRAWINGS
Dimensions: mm [inches]
PRESSURE CONNECTION
(1) G 1/4 MALE (DIN 3852-A)
(3) G 1/2 A (DIN 16288)
(2) SAE 04 AS4395 - E
(4) G 1/4 FEMALE
ELECTRICAL CONNECTION
P - 7 pole connector V - 6 pole connector F - 4 pole cable
Z - 4 pole connector
M12 x 1
E - 4 pole connector
EN 175301-803A
P 18 mm
M - 4 pole connector
EN 175301-803C
P 9.5 mm
ELECTRICAL CONNECTION - Connectors
P - 7-pole connector M16x0.75
V - 6-pole bayonet connector F - 2 pole cable
Shield
Red
Protection IP67
Z - M12 x 1 connector
2 1
3 4
Protection IP66
E - EN 175301-803A
M - EN 175301-803C
Shielded cable 2x0.25 - 2m. (output E)
Protection IP65
F - 4 pole cable
Shield White
Green
Red
4 pole male connector
Protection IP67
4 pin type A
Protection IP65
4 pin type C
Protection IP65
ELECTRICAL CONNECTION - connection diagrams
VOLTAGE AMPLFIED OUTPUT - mod. B/C/M/N/P/Q/R cod. V cod. P cod. F
CONTROLLER
C 1 White
POWER SUPPLY
D 2 Green
AMPLIFIER
A 3 Red
OUTPUT
B
Case
4
Yellow or
Black
Custodia Shield cod. E/M
3
2
1
2 cod. Z
3
2
1
2
Custodia
CURRENT AMPLIFIED OUTPUT - mod. E cod. V
CONTROLLER
POWER
SUPPLY
A
SIGNAL
B
AMPL/CONV cod. P
3
4 cod. F
Red
Yellow or
Black cod. E/M
1
2 cod. Z
1
2
Custodia Custodia Shield Custodia
Shielded cable 4x0.25 - 2m
Protection IP65
LOAD DIAGRAM
(Current output)
POWER SUPPLY VOLTAGE (Vd.c.)
OPERATING
AREA
ACCESSORIES ON REQUEST
Connectors Plugs
Connection E
EN 175301-803 4 poles type A (P.18)
Prot. IP65
Connection Z
4 poles connector Prot. IP67
CON 006
CON 293
Connection M
EN 175301-803 4 poles type C (P.9.5)
Prot. IP65
Connection P
7 poles female cable connector Prot. IP67
Connection V
6 poles female cable connector Prot. IP66
EXTENSION CABLES
6-pin connector with 8m (25ft) cable
6-pin connector with 15m (50ft) cable
C08WLS
C15WLS
6-pin connector with 30m (100ft) cable C30WLS
Other lengths factory
CON 008
CON 321
CON 300
B
C
D
E
F
Cable color code
Connector
A
Wire
Red
Yellow/Black
White
Green
Blue
Orange
ORDERING INFORMATION
Pressure transmitter TK
OUTPUT SIGNAL
Standard
0.1 ... 10.1 Vdc C
4...20 mA E
0...10 Vdc N
On request
0.1 ... 5.1 Vdc B
0 ... 5 Vdc M
1 ... 5 Vdc P
1 ... 10 Vdc Q
1 ... 6 Vdc R
PRESSURE CONNECTION
Standard
G 1/4 gas male (DIN 3852-A) 1
7/16-20 UNF-2A male
2
(SAE 4 per AS4395-E)
G 1/2A (DIN 16288) 3
On request
G 1/4 gas female 4
1/8-27 NPT female 5
1/4 - 18 NPT female 6
1/4 - 18 NPT male 7
M14 x 1.5 male 8
1/8 - 27 NPT male 9
G 1/4 gas male (DIN 3852-E) E
M12 x 1.5 male R
7/16-20 UNF-2A male
K
(SAE 4 per J1926-2) (*)
7/16-20 UNF-2A female
(*) Max. working pressure:
(SAE 4)
630 bar (9137 psi)
F
ELECTRICAL CONNECTION
Standard
EN 175301-803 type A (P 18 mm) E
Shielded cable F
4 pole connector M12 x 1 Z
On request
EN 175301-803 type C (P 9.5 mm) M
7 pole connector M16x0.75
P
6 pole bayonet connector V
Mechanical and/or electrical characteristics differing from standard may be arranged on request.
RESPONSE TIME
V Fast (< 1 msec)
ACCURCY
H ± 0.25% FS Typical
M ± 0.5% FS Typical
MEASUREMENT RANGE bar bar
N01U -1..+1 * B03D 0..30
N02U -1..+2 * B04D 0..40
N03U -1..+3 * B05D 0..50
N05U -1..+5 B06D 0..60
N01D -1..+10 B01C 0..100
psi
V15U -15..+15 *
V03D -15..+30 *
V05D -15..+50 *
V75U -15..+75
V01C -15..+100
B03U
B04U
B05U
B06U
0..3
0..4
0..5
0..6
B16D 0..160
B02C 0..200
B25D 0..250
B35D 0..350
P05D
P75U
P01C
P15D
0..50
0..75
0..100
0..150
B07U 0..7
B04C 0..400
B01D 0..10
B05C 0..500
B16U 0..16
B06C 0..600
B02D 0..20
B07C 0..700
P25D
P03C
P05C
P75D
0..250
0..300
0..500
0..750
B25U 0..25
B01M 0..1000
P01M 0..1000
P15C 0..1500
* only M class
P25C 0..2500
P03M 0..3000
P05M 0..5000
P75C 0..7500
P10M 0..10000
P15M 0..15000
C alibration
S tandardS
Instruments manufactured by Gefran are calibrated against precision pressure calibration equipment wich is traceable to International Standards.
Es: TK - E - 1 - E - B04C - H - V
Pressure transmitter TK with 4 to 20 mA output signal, G1/4 male pressure connection, EN 175301-803A connector, 0...400 bar pressure range, ± 0.25% FS accuracy, 1 msec response time
Sensors are manufactured in compliance with:
- EMC 2014/30/EU compatibility directive
- RoHS 2011/65/EU directive
Electrical installation requirements and Conformity certificate are available on our web site: www.gefran.com
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice
GEFRAN spa via Sebina, 74
25050 PROVAGLIO DʼISEO (BS) - ITALIA tel. 0309888.1 - fax. 0309839063
Internet: http://www.gefran.com
DTS_TK_03-2021_ENG