BEA UNIVERSAL RAIN ACCESSORY User Guide
BEA UNIVERSAL RAIN ACCESSORY is designed to protect your door sensor from rain and other elements. It is easy to install and can be used with both ULTIMO and IXIO sensors. The URA is made of durable materials and is built to last.
विज्ञापन
विज्ञापन
Visit website for available languages of this document.
UNIVERSAL RAIN ACCESSORY
Bracket accessory for ULTIMO and IXIO sensors
sensor not included cover base
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/ device outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines
(where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label
(e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are in place.
Tech Support & Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.BEAsensors.com
©BEA | Original Instructions
75.0056.02 UNIVERSAL RAIN ACCESSORY 20221215 Page 1 of 2
MOUNTING & ASSEMBLY
1. Verify the existing mounting location orientation:
• ULTIMO: the bottom of the sensor is no more than 5” from the bottom of the door header
• IXIO: the bottom of the sensor is no more than 2” from the bottom of the door header
1
2. Place the Universal Rain Accessory (URA) base in the desired mounting location, and mark and drill pilot holes. Remove existing sensor if necessary.
2
3. Secure the URA base to the mounting location using the provided screws.
3
4. Secure the sensor to the URA base using the screws provided with the sensor.
4
5. Wire as instructed in the applicable sensor’s User’s Guide and secure the sensor cover.
5
6. Slightly pull the sides of the cover and insert the pin guides on the inside of the URA cover into the outside of the URA base.
©BEA | Original Instructions
75.0056.02 UNIVERSAL RAIN ACCESSORY 20221215
Visit website for available languages of this document.
75.0034.05 ULTIMO 20220708
ULTIMO
ACTIVATION AND SAFETY SENSOR FOR
AUTOMATIC, SLIDING DOORS
Software version 2.5 / Configuration version 7.0
(refer to Admin menu for product software vesion)
Page 1 of 20
6
Page 2 of 2
डाउनलोड
विज्ञापन