SolarEdge DC Surge Protection Device Installation Guide
SolarEdge DC Surge Protection Device safeguards your three-phase inverter by diverting excess voltage to the ground, preventing damage to your solar system's electrical components. Its durable design ensures reliable protection against voltage spikes caused by lightning or grid faults. Easy to install, it's compatible with SolarEdge inverters featuring Synergy Technology and comes with a communication cable and spare screws for hassle-free replacement.
Advertisement
Advertisement
Version 1.0, May. 2021
DC Surge Protection Device Installation / Replacement in Three Phase
Inverters with Synergy Technology P/N: SExxK-xxxxlxxxx
This document describes how to install or replace the DC Surge Protection Device (SPD) in a Three Phase Inverter with Synergy
Technology.
Kit Contents
DC SPD Board
Spare screws
Required Tools
Torque 5mm hex screwdriver
Phillips screwdriver
Removing the Inverter Cover
If the cover of the Synergy Manager is not already removed, use the following procedure for cover removal.
To remove the inverter cover
1. Turn the ON/OFF/P Switch of the Synergy Manager to OFF (0). Wait for five minutes for the DC Voltage inside the inverter to drop to a safe level before preceding to the next step.
Synergy Manager
WARNING!
The inverter cover must be opened only after switching the inverter ON/OFF/P switch located at the bottom of the inverter to OFF. This disables the DC Voltage inside the inverter. Wait five minutes before opening the cover. Otherwise, there is a risk of electric shock from energy stored in the capacitors.
AVERTISSEMENT!
Ne pas ouvrir le couvercle de l'onduleur avant d'avoir coupé l'interrupteur situé en dessous de l'onduleur. Cela supprime les tensions CC et CA de l'onduleur. Attendre cinq minutes avant d’ouvrir le couvercle. Sinon, il y a un risque de choc
électrique provenant de l'énergie stockée dans le condensateur
2. Turn OFF the ON/OFF switch of the Synergy Manager.
3. Disconnect AC to the inverter by turning OFF the circuit breakers on the distribution panel.
4. Release the six Allen screws holding the inverter cover and remove the cover.
CAUTION!
When removing the inverter cover, make sure not to damage the internal components. SolarEdge will not be held responsible for any components damaged as a result of incautious cover removal.
ATTENTION!
Lors du retrait du couvercle, assurez-vous de ne pas endommager les composants internes. SolarEdge ne peut être tenue pour responsable des composants endommagés à la suite d'une imprudence dans le retrait du couvercle.
Replacing the DC SPD Board
To remove the DC SPD Board:
1. Disconnect the plug of the communication cable from the DC SPD Board.
MAN-01-00826-1.0 DC Surge Protection Device Installation/Replacement in Three Phase Inverters with Synergy Technology
2 Replacing the DC SPD Board
Figure 1: Plug of the Communication Cable of the DC SPD Board
2. Disconnect the lugs of the six power cables from the DC SPD Board.
Figure 2: Power Cable of DC SPD Board
2. Release the four screws fastening the DC SPD Board to the standoffs and remove the DC SPD Board.
Figure 3: Removal of the DC SPD Board
To Install the provided DC SPD Board:
1. Place the provided DC SPD Bard on the standoffs and fasten the four screws with a torque of 1.3 N*m (0.96 lb*ft).
2. Connect the lugs of the six power cables to the power board of the provided DC SPD Board and fasten the screws with a torque of 1.3 N*m (0.96 lb*ft).
3. Connect the plug of the communication cable to the DC SPD Board.
4. Close the Synergy Manager cover and fasten the six Allen screws with a torque of 3.5 N*m (2.6 lb*ft).
MAN-01-00826-1.0 DC Surge Protection Device Installation/Replacement in Three Phase Inverters with Synergy Technology