The IBM® Flex System™ x240 M5 Compute Node is a high-performance server that offers new security, efficiency, and reliability features to handle business-critical workloads. The blade server is based on the
Intel Xeon E5-2600 v3 processors. It features up to 18 cores and uses new IBM TruDDR4 Memory, which runs at speeds up to 2133 MHz.
Suggested uses: Database, virtualization, enterprise applications, collaboration and email, streaming media, web, HPC, and cloud applications.
Figure 1 shows the IBM Flex System x240 M5 Compute Node.
Figure 1. The IBM Flex System x240 M5 Compute Node
Did you know?
The x240 M5 Compute Node uses IBM TruDDR4 Memory DIMM technology, which offers higher clock speeds, faster data transfer rates, and runs at a lower voltage (1.2V). With DDR4 technology, memory
DIMMs can now operate at speeds up to 2133 MHz, which provides lower latency times and enhanced computing power. The TruDDR4 Memory portfolio includes RDIMMs with advanced error correction for reliability, performance, and maximum memory capacity. In addition, TruDDR4 Memory supports memory performance that exceeds industry standards.
The x240 M5 Compute Node integrates leadership security and reliability. System x Trusted Platform
Assurance, an exclusive set of System x features and practices, establishes a foolproof security foundation for your workloads. Enterprise-class data protection is provided with optional self-encrypting drives and simple, centralized key management through IBM Security Key Lifecycle Management.
Diagnostic tools facilitate reduced downtime and costs.
IBM Flex System x240 M5 Product Guide 1
Key features
The IBM Flex System x240 M5 Compute Node is a high-availability, scalable compute node that is optimized to support the next-generation microprocessor technology. It is ideally suited for medium and large businesses. This section describes the key features of the server.
Scalability and performance
The x240 M5 offers the following features to boost performance, improve scalability, and reduce costs:
Improves productivity by offering superior system performance with up to 18-core processors, up to
45 MB of L3 cache, and up to 9.6 GT/s QPI interconnect links.
Supports up to two processors, 36 cores, and 72 threads, which maximizes the concurrent execution of multi-threaded applications.
Intelligent and adaptive system performance with energy efficient Intel Turbo Boost Technology allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
Intel Advanced Vector Extensions 2.0 (AVX 2.0) enable acceleration of enterprise-class workloads, such as databases and enterprise resource planning.
Up to 2133 MHz memory speeds with two DIMMs per channel that are running at 2133 MHz to help maximize system performance.
Up to 1.5 TB of memory capacity with 64 GB load-reduced DIMMs, or LRDIMMs (support for 64 GB
LRDIMMs is planned for a later date).
Optional support for high-performance PCIe-attached NVMe Flash Storage solid-state drives (SSDs) can significantly improve I/O performance.
Supports the Storage Expansion Node, which provides another 12 hot-swap, 2.5-inch drive bays for local storage.
Up to 16 virtual I/O ports per compute node with available 10 Gb Virtual Fabric Adapters, which offers the choice of Ethernet, Fibre Channel, iSCSI, or Fibre Channel over Ethernet (FCoE) connectivity.
The x240 M5 offers PCI Express 3.0 I/O expansion capabilities that improve the theoretical maximum bandwidth by 60% (8 GT/s per link), compared with the previous generation of PCI Express 2.0.
With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E5 family. This integration helps to dramatically reduce I/O latency and increase overall system performance.
Support for high-bandwidth I/O adapters, up to two in each x240 M5 Compute Node.
Support for 10 Gb Ethernet, 16 Gb Fibre Channel, and FDR InfiniBand.
Supports the PCIe Expansion Node for support for up to six more I/O adapters.
High-speed USB 3.0 port for connectivity to external devices.
IBM Flex System x240 M5 Product Guide 2
Availability and serviceability
The x240 M5 provides the following features to simplify serviceability and increase system up-time:
Chipkill, memory mirroring, and memory rank sparing for redundancy if there is a non-correctable memory failure.
Tool-less cover removal provides easy access to upgrades and serviceable parts, such as CPU, memory, and adapter cards.
Hot-swap drives support integrated RAID 1 redundancy for data protection and greater system up-time.
A light path diagnostics panel and individual light path LEDs to quickly lead the technician to failed (or failing) components. This feature simplifies servicing, speeds up problem resolution, and helps improve system availability.
Predictive Failure Analysis (PFA), which detects when system components (such as processors, memory, and hard disk drives) operate outside of standard thresholds and generates pro-active alerts in advance of possible failure, which increases uptime.
Solid-state drives (SSDs), which offer significantly better reliability than traditional mechanical HDDs for greater uptime.
Built-in Integrated Management Module II (IMM2) continuously monitors system parameters, triggers alerts, and performs recovering actions if there is a failure to minimize downtime.
Built-in diagnostics that uses Dynamic Systems Analysis (DSA) Preboot speeds up troubleshooting tasks to reduce service time.
Three-year customer replaceable unit and on-site limited warranty; next business day 9x5. Optional service upgrades are available.
Manageability and security
The following powerful systems management features simplify the local and remote management of the x240 M5:
The x240 M5 includes an IMM2 to monitor server availability and perform remote management.
Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
Integrated Trusted Platform Module (TPM) 1.2 support enables advanced cryptographic functionality, such as digital signatures and remote attestation.
System x Trusted Platform Assurance, an exclusive set of System x security features and practices, establishes a foolproof security foundation for workloads by delivering firmware that is securely built, tested, digitally signed, and verified before execution.
The server offers enterprise-class data protection with optional self-encrypting drives and simple, centralized key management through IBM Security Key Lifecycle Management.
Industry-standard AES NI support for faster, stronger encryption.
Integrates with the IBM® Flex System™ Manager for proactive systems management. It offers comprehensive systems management for the entire IBM Flex System platform that helps to increase up-time, reduce costs, and improve productivity through advanced server management capabilities.
IBM Fabric Manager simplifies deployment of infrastructure connections by managing network and storage address assignments.
IBM Flex System x240 M5 Product Guide 3
Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system.
Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, which allows an application to run in its own isolated space that is protected from all other software that is running on a system.
Energy efficiency
The x240 M5 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:
Component-sharing design of the IBM Flex System chassis provides ultimate power and cooling savings.
The Intel Xeon processor E5-2600 v3 product family offers significantly better performance over the
E5-2600 v2 family while fitting into the same thermal design power (TDP) limits.
Intel Intelligent Power Capability powers individual processor elements on and off as needed, which reduces power draw.
Low-voltage Intel Xeon processors draw less energy to satisfy demands of power and thermally constrained data centers and telecommunication environments.
Low-voltage 1.2 V DDR4 memory DIMMs use up to 20% less energy compared to 1.35 V DDR3
DIMMs.
Solid state drives (SSDs) use as much as 80% less power than traditional spinning 2.5-inch HDDs.
The x240 M5 uses hexagonal ventilation holes, which are a part of IBM Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, which provides more efficient airflow through the system.
IBM Flex System x240 M5 Product Guide 4
Locations of key components and connectors
Figure 2 shows the front of the server.
Figure 2. Front view of the IBM Flex System x240 M5 Compute Node
Figure 3 shows the locations of key components inside the server.
Figure 3. Inside view of the IBM Flex System x240 M5 Compute Node
IBM Flex System x240 M5 Product Guide 5
Standard specifications
The following table lists the standard specifications.
Table 1. Standard specifications (part 1)
Components
Models
Specification
9532-x2x, 9532-x4x, 9532-x6x
Form factor Standard-width compute node.
Chassis support IBM Flex System Enterprise Chassis.
Processor Up to two Intel Xeon processor E5-2600 v3 product family CPUs with 18 cores (2.3 GHz), 16 cores (2.3 GHz), 14 cores (up to 2.6 GHz), 12 cores (up to 2.6 GHz) or 10 cores (up to 2.6
GHz), 8 cores (up to 3.2 GHz), 6 cores (up to 3.4 GHz), or up to 4 cores (up to 3.5 GHz). Two
QPI links up to 9.6 GTps each. Up to 2133 MHz memory speed. Up to 45 MB L3 cache.
Chipset
Memory
Intel C612
Up to 24 DIMM sockets (12 DIMMs per processor). RDIMMs and LRDIMMs are supported.
Memory types cannot be intermixed. Memory speed up to 2133 MHz. Four memory channels per processor (3 DIMMs per channel).
Memory maximums
Memory protection
With LRDIMMs: Up to 1.5 TB with 24x 64 GB LRDIMMs and two processors
With RDIMMs: Up to 384 GB with 24x 16 GB RDIMMs and two processors
ECC, optional memory mirroring and memory rank sparing.
Disk drive bays Two 2.5-inch hot-swap SAS/SATA drive bays that support SAS, SATA, and SSDs. Optional support for 2.5-inch NVMe Enterprise PCIe SSDs. Optional support for up to four 1.8-inch SSDs in place of the two 2.5-inch bays. Up to 12 more 2.5-inch drive bays with the optional Storage
Expansion Node.
Maximum internal storage
With two 2.5-inch hot-swap drives: Up to 3.2 TB that uses 1.6 TB 2.5-inch SATA SSDs or up to
2.4 TB that uses 1.2 TB SAS HDDs. An intermix of SAS HDDs or SATA HDDs or SSDs is supported.
With two 2.5-inch NVMe SSDs: Up to 4 TB that uses 2 TB NVMe 2.5-inch G3HS Enterprise
Value PCIe SSDs.
With four 1.8-inch SSDs: Up to 3.2 TB that uses 800 GB 1.8-inch SSDs.
More storage is available with an attached Flex System Storage Expansion Node.
RAID support
Network interfaces
RAID 0 and 1 with integrated LSI SAS3004 controller. Optional RAID 5 support with ServeRAID
M1200 RAID 5 Enablement Kit and 1.8-inch SSDs x2x models: None standard; optional 1 Gb or 10 GbE adapters.
x4x models: Two 10 GbE ports with EN4172 2-port 10Gb Ethernet Adapter.
x6x models: Two 10 GbE ports with CN4052 2-port 10Gb Virtual Fabric Adapter.
PCI Expansion slots
Ports
Two I/O connectors for adapters. PCI Express 3.0 x16 interface. Includes an Expansion
Connector (PCIe 3.0 x16) to connect an expansion node, such as the PCIe Expansion Node.
PCIe Expansion Node supports two full-height PCIe adapters, two low-profile PCIe adapters, and two Flex System I/O adapters.
Front: One USB 3.0 port and one console breakout cable port that provides local KVM and serial ports (cable standard with chassis; more cables optional).
Internal: Optional SD Media Adapter provides two SD Media slots for VMware vSphere hypervisor support (RAID 1 pair).
IBM Flex System x240 M5 Product Guide 6
Table 1. Standard specifications (part 2)
Components
Systems management
Specification
UEFI, IBM Integrated Management Module 2 (IMM2) with Renesas SH7758 controller,
Predictive Failure Analysis, light path diagnostics panel, automatic server restart, remote presence. Support for IBM Flex System Manager™, IBM Systems Director and Active Energy
Manager, IBM Tools Center.
Power-on password, administrator's password, Trusted Platform Module 1.2.
Security features
Video Matrox G200eR2 video core with 16 MB video memory integrated into the IMM2. Maximum resolution is 1600x1200 at 75 Hz with 16 M colors.
Three-year customer-replaceable unit and on-site limited warranty with 9x5/NBD.
Limited warranty
Operating systems supported
Service and support
Dimensions
Weight
Microsoft Windows Server 2012 and 2012 R2, Red Hat Enterprise Linux 6 and 7, SUSE Linux
Enterprise Server 11, VMware vSphere 5.1 and 5.5. For more information, see "Supported operating systems."
Optional service upgrades are available through IBM ServicePacs®: 4-hour or 2-hour response time, 8-hour fix time, 1-year or 2-year warranty extension, remote technical support for IBM hardware and selected IBM and original equipment manufacturer (OEM) software.
Width: 215 mm (8.5 inches), height 51 mm (2.0 inches), depth 493 mm (19.4 inches).
Maximum configuration: 7.1 kg (15.6 lb).
The x240 M5 servers are shipped with the following items:
Statement of Limited Warranty
Important Notices
Documentation CD that contains the Installation and User's Guide
IBM Flex System x240 M5 Product Guide 7
Standard models
Table 2 lists the standard models.
Table 2. Standard models (Part 1)
Model Intel Xeon Processor
(2 maximum)*
Memory Disk adapter
Disk bays†
(used/max)
Disks 10 GbE‡ I/O slots
(used / max)
Models with no Ethernet adapter standard
9532-A2x 1x E5-2609 v3 6C 1.9GHz
15MB 1600MHz 85W
9532-B2x 1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
9532-C2x 1x E5-2630 v3 8C 2.4GHz
20MB 1866MHz 85W
9532-D2x 1x E5-2640 v3 8C 2.6GHz
9532-J2x
20MB 1866MHz 90W
9532-F2x 1x E5-2650L v3 12C 1.8GHz
30MB 2133MHz 65W
9532-G2x 1x E5-2650 v3 10C 2.3GHz
25MB 2133MHz 105W
9532-H2x 1x E5-2660 v3 10C 2.6GHz
25MB 2133MHz 105W
1x E5-2670 v3 12C 2.3GHz
30MB 2133MHz 120W
9532-L2x 1x E5-2680 v3 12C 2.5GHz
30MB 2133MHz 120W
9532-M2x 1x E5-2690 v3 12C 2.6GHz
30MB 2133MHz 135W
1x 16 GB
2133 MHz
1x 16 GB
2133 MHz
1x 16 GB
2133 MHz
1x 16 GB
2133 MHz
1x 16 GB
2133 MHz
1x 16 GB
(1600 MHz)
1x 16 GB
(1866 MHz)
1x 16 GB
(1866 MHz)
1x 16 GB
(1866 MHz)
1x 16 GB
2133 MHz
LSI SAS3004
LSI SAS3004
LSI SAS3004
LSI SAS3004
LSI SAS3004
LSI SAS3004
LSI SAS3004
LSI SAS3004
LSI SAS3004
LSI SAS3004
2.5” hot-swap (0 / 2)
2.5” hot-swap (0 / 2)
2.5” hot-swap (0 / 2)
2.5” hot-swap (0 / 2)
2.5” hot-swap (0 / 2)
2.5” hot-swap (0 / 2)
2.5” hot-swap (0 / 2)
2.5” hot-swap (0 / 2)
2.5” hot-swap (0 / 2)
2.5” hot-swap (0 / 2)
9532-N2x 1x E5-2697 v3 14C 2.6GHz
35MB 2133MHz 145W
9532-Q2x 1x E5-2698 v3 16C 2.3GHz
40MB 2133MHz 135W
1x 16 GB
2133 MHz
1x 16 GB
2133 MHz
Models with EN4172 2-port 10Gb Ethernet Adapter standard
LSI SAS3004 2.5” hot-swap (0 / 2)
LSI SAS3004 2.5” hot-swap (0 / 2)
LSI SAS3004 2.5” hot-swap (0 / 2) 9532-B4x 1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
9532-D4x 1x E5-2640 v3 8C 2.6GHz
20MB 1866MHz 90W
1x 16 GB
(1866 MHz)
1x 16 GB
(1866 MHz)
LSI SAS3004 2.5” hot-swap (0 / 2)
9532-H4x 1x E5-2660 v3 10C 2.6GHz
25MB 2133MHz 105W
1x 16 GB
2133 MHz
LSI SAS3004 2.5” hot-swap (0 / 2)
Open Open
Open Open
Open Open
Open Open
Open Open
Open Open
Open Open
Open Open
Open Open
Open Open
Open Open
Open Open
0 / 2
0 / 2
0 / 2
0 / 2
0 / 2
0 / 2
0 / 2
0 / 2
0 / 2
0 / 2
0 / 2
0 / 2
Open 2x 10 Gb 1 / 2
Open 2x 10 Gb 1 / 2
Open 2x 10 Gb 1 / 2
9532-J4x 1x E5-2670 v3 12C 2.3GHz
30MB 2133MHz 120W
9532-L4x 1x E5-2680 v3 12C 2.5GHz
30MB 2133MHz 120W
1x 16 GB
2133 MHz
1x 16 GB
2133 MHz
LSI SAS3004 2.5” hot-swap (0 / 2)
LSI SAS3004 2.5” hot-swap (0 / 2)
Open 2x 10 Gb 1 / 2
Open 2x 10 Gb 1 / 2
* Processor detail: Processor quantity, model, cores, core speed, L3 cache, memory speed, power TDP rating.
† The two 2.5-inch drive bays can be replaced with four 1.8-inch SSD bays.
IBM Flex System x240 M5 Product Guide 8
Table 2. Standard models (Part 2)
Model Intel Xeon Processor
(2 maximum)*
Memory
(max
786 GB)
Disk adapter
Models with CN4052 2-port 10Gb Virtual Fabric Adapter standard
Disk bays† Disks 10 GbE‡ I/O slots
LSI SAS3004 2.5-inch hot-swap (0 / 2) Open 2x 10 Gb 1 / 2 9532-B6x 1x E5-2620 v3 6C 2.4GHz
15MB 1866MHz 85W
9532-D6x 1x E5-2640 v3 8C 2.6GHz
20MB 1866MHz 90W
1x 16 GB
(1866 MHz)
1x 16 GB
(1866 MHz)
LSI SAS3004 2.5-inch hot-swap (0 / 2) Open 2x 10 Gb 1 / 2
9532-H6x 1x E5-2660 v3 10C 2.6GHz
25MB 2133MHz 105W
9532-J6x 1x E5-2670 v3 12C 2.3GHz
30MB 2133MHz 120W
1x 16 GB
2133 MHz
1x 16 GB
2133 MHz
LSI SAS3004 2.5-inch hot-swap (0 / 2) Open 2x 10 Gb 1 / 2
LSI SAS3004 2.5-inch hot-swap (0 / 2) Open 2x 10 Gb 1 / 2
9532-L6x 1x E5-2680 v3 12C 2.5GHz
30MB 2133MHz 120W
1x 16 GB
2133 MHz
LSI SAS3004 2.5-inch hot-swap (0 / 2) Open 2x 10 Gb 1 / 2
* Processor detail: Processor quantity, model, cores, core speed, L3 cache, memory speed, power TDP rating.
† The two 2.5-inch drive bays can be replaced with four 1.8-inch SSD bays.
IBM Flex System x240 M5 Product Guide 9
Chassis support
The x240 M5 is supported in the IBM Flex System Enterprise Chassis.
Up to 14 x240 M5 Compute Nodes can be installed in the chassis; however, the actual number that can be installed in a chassis depends on the following factors:
TDP power rating for the processors that are installed in the x240 M5
Number of power supplies that are installed in the chassis
Capacity of the installed power supplies (2100 W or 2500 W)
Chassis power redundancy policy that is used (N+1 or N+N)
The following table provides guidelines about what number of x240 M5 Compute Nodes can be installed.
For more information, use the Power Configurator, which is found at the following website: http://ibm.com/systems/bladecenter/resources/powerconfig.html
The following color coding was used In the table:
Green = No restriction on the number of x240 M5 Compute Nodes that can be installed
Yellow = Some bays must be left empty in the chassis
x240 M5
TDP rating
70 W
80 W
85 W
105 W
120 W
130 W
135 W
145 W
Table 3. Maximum number of x240 M5 Compute Nodes that can be installed based on installed power supplies and power redundancy policy used
2100 W power supplies installed
14
14
14
14
14
14
N+1, N=5
6 power supplies
14
14
N+1, N=4
5 power supplies
14
14
14
14
14
13
13
13
N+1, N=3
5 power supplies
12
12
12
11
10
10
10
9
2500 W power supplies installed
12
11
11
10
10
10
N+N, N=3
6 power supplies
13
12
14
14
14
14
14
14
N+1, N=5
6 power supplies
14
14
N+1, N=4
5 power supplies
14
14
14
14
14
14
14
14
N+1, N=3
4 power supplies
14
14
14
13
13
12
12
12
14
14
14
13
13
13
N+N, N=3
6 power supplies
14
14
IBM Flex System x240 M5 Product Guide 10
Processor options
The x240 M5 supports the processor options that are listed in the following table. The server supports one or two processors. The table also shows which server models have each processor standard, if any.
Table 4. Processor options
Part number
Feature code*
00JX063 A5T1 / A5SJ
00KJ052 AS35 / AS3F
00JX062 A5T2 / A5SK
00KJ051 AS34 / AS3E
00JX060 A5T3 / A5SL
00KJ048 AS31 / AS3B
00KJ050 AS33 / AS3D
00JX059 A5T5 / A5SN
00JX061 A5T4 / A5SM
00JX066 A5T6 / A5SP
00JX058 A5T7 / A5SQ
00JX065 A5T8 / A5SR
00KJ049 AS32 / AS3C
00JX056 A5TA / A5ST
00JX057 A5T9 / A5SS
00KJ044 AS2X / AS37
00JX055 A5TB / A5SU
00JX064 A5TC / A5SV
00JX054 A5TD / A5SW
00JX053 A5TE / A5SX
Intel Xeon processor description
Intel Xeon E5-2603 v3 6C 1.6GHz 15MB 1600MHz 85W
Intel Xeon E5-2608L v3 6C 2.0GHz 15MB 1866MHz 52W
Intel Xeon E5-2609 v3 6C 1.9GHz 15MB 1600MHz 85W
Intel Xeon E5-2618L v3 8C 2.3GHz 20MB 1866MHz 75W
Intel Xeon E5-2620 v3 6C 2.4GHz 15MB 1866MHz 85W
Intel Xeon E5-2623 v3 4C 3.0GHz 10MB 1866MHz 105W
Intel Xeon E5-2628L v3 10C 2.0GHz 25MB 1866MHz 75W
Intel Xeon E5-2630 v3 8C 2.4GHz 20MB 1866MHz 85W
Intel Xeon E5-2630L v3 8C 1.8GHz 20MB 1866MHz 55W
Intel Xeon E5-2637 v3 4C 3.5GHz 15MB 2133MHz 135W
Intel Xeon E5-2640 v3 8C 2.6GHz 20MB 1866MHz 90W
Intel Xeon E5-2643 v3 6C 3.4GHz 20MB 2133MHz 135W
Intel Xeon E5-2648L v3 12C 1.8GHz 30MB 2133MHz 75W
Intel Xeon E5-2650 v3 10C 2.3GHz 25MB 2133MHz 105W
Intel Xeon E5-2650L v3 12C 1.8GHz 30MB 2133MHz 65W
Intel Xeon E5-2658 v3 12C 2.2GHz 30MB 2133MHz 105W
Intel Xeon E5-2660 v3 10C 2.6GHz 25MB 2133MHz 105W
Intel Xeon E5-2667 v3 8C 3.2GHz 20MB 2133MHz 135W
Intel Xeon E5-2670 v3 12C 2.3GHz 30MB 2133MHz 120W
Intel Xeon E5-2680 v3 12C 2.5GHz 30MB 2133MHz 120W
00KJ047 AS30 / AS3A
00KJ046 AS2Z / AS39
00JX052 A5TF / A5SY
00JX051 A5TG / A5SZ
Intel Xeon E5-2683 v3 14C 2.0GHz 35MB 2133MHz 120W
Intel Xeon E5-2685 v3 12C 2.6GHz 30MB 2133MHz 120W
Intel Xeon E5-2690 v3 12C 2.6GHz 30MB 2133MHz 135W
Intel Xeon E5-2695 v3 14C 2.3GHz 35MB 2133MHz 120W
00JX050 A5TH / A5T0
00KJ045 AS2Y / AS38
Intel Xeon E5-2697 v3 14C 2.6GHz 35MB 2133MHz 145W
Intel Xeon E5-2698 v3 16C 2.3GHz 40MB 2133MHz 135W
00KJ043 AS2W / AS36 Intel Xeon E5-2699 v3 18C 2.3GHz 45MB 2133MHz 145W
* The first feature code is for processor 1 and second feature code is for processor 2.
-
-
-
M2x
-
N2x
Q2x
-
-
Models where used
-
-
A2x
-
B2x, B4x, B6x
-
-
G2x
F2x
-
C2x
-
D2x, D4x, D6x
-
H2x, H4x, H6x
-
J2x, J4x, J6x
L2x, L4x, L6x
IBM Flex System x240 M5 Product Guide 11
Memory options
TruDDR4 Memory uses the highest quality components that are sourced from Tier 1 DRAM suppliers and only memory that meets the strict requirements of IBM is selected. It is compatibility tested and tuned on every IBM System x server to maximize performance and reliability. TruDDR4 Memory has a unique signature that is programmed into the DIMM that enables IBM System x servers to verify whether the memory that is installed is qualified or supported by IBM. Because TruDDR4 Memory is authenticated, certain extended memory performance features can be enabled to extend performance over industry standards. From a service and support standpoint, IBM memory automatically assumes the IBM system warranty and IBM provides service and support worldwide.
The following table lists the supported memory options.
Table 5. Memory options for the x240 M5
Part number
Feature code
Description Models where used
Registered DIMMs (RDIMMs)
46W0784 A5B6 4GB TruDDR4 Memory (1Rx8, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM -
46W0788 A5B5 8GB TruDDR4 Memory (1Rx4, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM -
46W0792 A5B8 8GB TruDDR4 Memory (2Rx8, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM -
95Y4821 ASD9 16GB TruDDR4 Memory (2Rx4, 1.2V) PC4-17000 CL15 2133MHz LP RDIMM All models
Load-reduced DIMMs (LRDIMMs)
46W0800 A5B9 32GB TruDDR4 Memory (4Rx4, 1.2V) PC417000 CL15 2133MHz LP LRDIMM -
95Y4812 A5UK 64GB TruDDR4 Memory (4Rx4,1.2V) PC4-17000 CL15 2133MHz LP LRDIMM -
The server supports up to 12 TruDDR Memory DIMMs when one processor is installed and up to 24
DIMMs when two processors are installed. Each processor has four memory channels, and there are three DIMMs per memory channel (3 DPC). RDIMMs and LRDIMMs are supported, but the mixing of these different types is not supported. UDIMMs are not supported. DIMMs can be installed individually; however, install them in sets of four (one for each of the four memory channels) for performance reasons.
The following rules apply when the memory configuration is selected:
Mixing of different types of DIMMs (RDIMM and LRDIMM) in the same server is not supported.
The maximum number of supported ranks per channel is eight.
The maximum quantity of DIMMs that can be installed in the server depends on the number of CPUs,
DIMM rank and operating voltage, as shown in the "Maximum quantity" row in the following table. The shaded cells indicate that the DIMM type supports the maximum number of DIMMs (24 for the x240
M5).
IBM Flex System x240 M5 Product Guide 12
All DIMMs in all CPU memory channels operate at the same speed, which is determined as the lowest value of the following factors:
Memory speed that is supported by the specific CPU.
Lowest maximum operating speed for the selected memory configuration that depends on rated speed, as shown in the "Maximum operating speed" section in the following table. The shaded cells indicate that the speed indicated is the maximum that the DIMM allows.
The following table shows the maximum memory speeds that are achievable based on the installed
DIMMs and the number of DIMMs per channel. The table also shows the maximum memory capacity at any speed that is supported by the DIMM and maximum memory capacity at rated DIMM speed. In the table, cells that are highlighted in gray indicate when the specific combination of DIMM voltage and number of DIMMs per channel still allows the DIMMs to operate at the rated speed.
Table 6. Maximum memory speeds
Specification
Rank
Part numbers
Rated speed
Rated voltage
Operating voltage
Maximum quantity*
Largest DIMM
Max memory capacity
Max memory at rated speed
Single rank
46W0784 (4 GB)
46W0788 (8 GB)
2133 MHz
1.2 V
1.2 V
24
8 GB
192 GB
128 GB
RDIMMs
Dual rank
46W0792 (8 GB)
95Y4821 (16 GB)
2133 MHz
1.2 V
1.2 V
24
16 GB
384 GB
256 GB
LRDIMMs
Quad rank
46W0800 (32 GB)
95Y4812 (64 GB)†
2133 MHz
1.2 V
1.2 V
24
64 GB
1.5 TB
1.0 TB
Maximum operating speed (MHz)
One DIMM per channel
Two DIMMs per channel
2133 MHz
2133 MHz
2133 MHz
2133 MHz
2133 MHz
2133 MHz
Three DIMMs per channel 1600 MHz 1600 MHz 1866 MHz
* The maximum quantity that is supported is shown for two processors that are installed. When one processor is installed, the maximum quantity that is supported is half of that shown.
† 64 GB LRDIMM planned for 4Q/2014
The following memory protection technologies are supported:
ECC
Memory mirroring
Memory sparing
If memory mirroring is used, DIMMs must be installed in pairs (minimum of one pair per CPU), and both
DIMMs in a pair must be identical in type and size.
If memory rank sparing is used, a minimum of one quad-rank DIMM or two single-rank or dual-rank
DIMMs must be installed per populated channel (the DIMMs do not need to be identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs that are installed.
IBM Flex System x240 M5 Product Guide 13
Internal storage
The x240 M5 server has two 2.5-inch hot-swap drive bays that are accessible from the front of the blade server (see Figure 2). These bays connect to the integrated LSI SAS3004 12 Gbps SAS/SATA
RAID-on-Chip (ROC) controller.
The integrated LSI SAS3004 ROC has the following features:
Four-port LSI SAS3004 controller with 12 Gbps throughput per port
PCIe x4 Gen 2 host interface
Two SAS ports routed internally to the two hot-swap drive bays
Supports RAID-0, RAID-1 and RAID-1E
The two 2.5-inch front-accessible drive bays can be replaced with four 1.8-inch drive bays, two 1.8-inch bays replacing each 2.5-inch bay, by using the ServeRAID M1200 RAID 5 Enablement Kit, 00JX141. This kit contains a replacement backplane to connect the four 1.8-inch SSDs. The kit also includes ServeRAID
M1200 Zero Cache/RAID 5 Upgrade (Feature on Demand license), which adds RAID 5 support. The part number for this upgrade is listed in the table.
The two standard 2.5-inch SAS/SATA drive bays can also be replaced with new PCIe NVMe
(Non-Volatile Memory Express) drives that are directly connected to the PCIe bus of the second processor. Such connectivity, when combined with SSD drives, ensures the lowest possible latency while still using a standard drive form factor.
Support for NVMe drives requires a replacement drive backplane for the two 2.5-inch drives plus the second processor must also be installed in the server. The kit containing the backplane, NVMe Enterprise
PCIe SSD Enablement Kit for IBM Flex System x240 M5, is listed in the following table.
Table 7. Internal storage upgrades
Part number
Feature code
00JX141 A5SF
00JX177 A5SH
Name and description
ServeRAID M1200 RAID 5 Enablement Kit for IBM Flex System x240 M5
NVMe Enterprise PCIe SSD Enablement Kit for IBM Flex System x240 M5
1
1
Maximum supported
Supported drives are listed in the "Internal drive options" section.
IBM Flex System x240 M5 Product Guide 14
Internal drive options
The 2.5-inch drive bays support SAS or SATA HDDs or SATA SSDs. The following table lists the supported 2.5-inch drive options.
Table 8. 2.5-inch drive options for internal disk storage (Part 1)
Part
number
Feature code
Description
10K SAS hard disk drives
00AJ096 A4TL IBM 300GB 10K 6Gbps SAS 2.5-inch G3HS HDD
00AJ091
00AJ071
A4TM
A4TN
IBM 600GB 10K 6Gbps SAS 2.5-inch G3HS HDD
IBM 900GB 10K 6Gbps SAS 2.5-inch G3HS HDD
00AJ146 A4TP
15K SAS hard disk drives
IBM 1.2TB 10K 6Gbps SAS 2.5-inch G3HS HDD
00AJ111 A4TQ IBM 146GB 15K 6Gbps SAS 2.5-inch G3HS HDD
00AJ081
00AJ126
A4TR
A4TS
IBM 300GB 15K 6Gbps SAS 2.5-inch G3HS HDD
IBM 600GB 15K 6Gbps SAS 2.5-inch G3HS HDD
10K and 15K self-encyrpting disk drives (SED HDDs)
00AJ106 A4TY IBM 300GB 10K 6Gbps SAS 2.5-inch G3HS SED
00AJ101
00AJ076
00AJ151
00AJ116
A4TZ
A4U0
A4U1
A4U2
IBM 600GB 10K 6Gbps SAS 2.5-inch G3HS SED
IBM 900GB 10K 6Gbps SAS 2.5-inch G3HS SED
IBM 1.2TB 10K 6Gbps SAS 2.5-inch G3HS SED
IBM 146GB 15K 6Gbps SAS 2.5-inch G3HS SED
NL SAS
00AJ121
00AJ086
NL SATA
00AJ131
A4TT
A4TU
A4TV
IBM 500GB 7.2K 6Gbps NL SAS 2.5-inch G3HS HDD
IBM 1TB 7.2K 6Gbps NL SAS 2.5-inch G3HS HDD
IBM 250GB 7.2K 6Gbps NL SATA 2.5-inch G3HS HDD
00AJ136
00AJ141
A4TW
A4TX
IBM 500GB 7.2K 6Gbps NL SATA 2.5-inch G3HS HDD
IBM 1TB 7.2K 6Gbps NL SATA 2.5-inch G3HS HDD
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Maximum supported
IBM Flex System x240 M5 Product Guide 15
Table 8. 2.5-inch drive options for internal disk storage (Part 2)
Part
number
Feature code
Description
6 Gb solid-state drives - Enterprise
00AJ207 A4UA IBM 200GB SAS 2.5-inch MLC G3HS Enterprise SSD
00AJ212
00AJ217
00AJ222
00AJ156
00AJ161
A4UB
A4UC
A4UD
A4U3
A4U4
IBM 400GB SAS 2.5-inch MLC G3HS Enterprise SSD
IBM 800GB SAS 2.5-inch MLC G3HS Enterprise SSD
IBM 1.6TB SAS 2.5-inch MLC G3HS Enterprise SSD
S3700 200GB SATA 2.5-inch MLC G3HS Enterprise SSD
S3700 400GB SATA 2.5-inch MLC G3HS Enterprise SSD
00AJ166 A4U5 S3700 800GB SATA 2.5-inch MLC G3HS Enterprise SSD
6 Gb solid-state drives - Enterprise Value
00AJ395
00AJ400
A577
A578
IBM 120GB SATA 2.5-inch MLC G3HS Enterprise Value SSD
IBM 240GB SATA 2.5-inch MLC G3HS Enterprise Value SSD
00AJ405
00AJ410
A579
A57A
IBM 480GB SATA 2.5-inch MLC G3HS Enterprise Value SSD
IBM 800GB SATA 2.5-inch MLC G3HS Enterprise Value SSD
PCIe NVMe solid-state drives
90Y3227 A5RW P3600 400GB NVMe 2.5-inch G3HS Enterprise Value PCIe SSD
90Y3230
90Y3233
90Y3236
A5RX
A5RY
A5RZ
P3600 800GB NVMe 2.5-inch G3HS Enterprise Value PCIe SSD
P3600 1.6TB NVMe 2.5-inch G3HS Enterprise Value PCIe SSD
P3600 2.0TB NVMe 2.5-inch G3HS Enterprise Value PCIe SSD
2
2
2
2
2
2
2
Maximum supported
2
2
2
2
2
2
2
2
IBM Flex System x240 M5 Product Guide 16
The supported 1.8-inch SSDs are listed in the following table. The use of 1.8-inch requires the
ServeRAID M1200 RAID 5 Enablement Kit, 00JX141.
Table 9. Supported 1.8-inch SSDs
Part
number
Feature code
Description
Enterprise SSDs
41Y8366
41Y8371
A4FS
A4FT
Enterprise Value SSDs
00AJ040
00AJ045
A4KV
A4KW
00AJ050
00AJ455
00AJ335
A4KX
A58U
A56V
00AJ340
00AJ345
00AJ350
A56W
A56X
A56Y
S3700 200GB SATA 1.8-inch MLC Enterprise SSD
S3700 400GB SATA 1.8-inch MLC Enterprise SSD
S3500 80GB SATA 1.8-inch MLC Enterprise Value SSD
S3500 240GB SATA 1.8-inch MLC Enterprise Value SSD
S3500 400GB SATA 1.8-inch MLC Enterprise Value SSD
S3500 800GB SATA 1.8-inch MLC Enterprise Value SSD
IBM 120GB SATA 1.8-inch MLC Enterprise Value SSD
IBM 240GB SATA 1.8-inch MLC Enterprise Value SSD
IBM 480GB SATA 1.8-inch MLC Enterprise Value SSD
IBM 800GB SATA 1.8-inch MLC Enterprise Value SSD
4
4
Maximum supported
4
4
4
4
4
4
4
4
IBM Flex System x240 M5 Product Guide 17
IBM Flex System Storage Expansion Node
The x240 M5 supports the attachment of the IBM Flex System Storage Expansion Node. The IBM Flex
System Storage Expansion Node provides the ability to attach another 12 hot-swap 2.5-inch HDDs or
SSDs locally to the attached compute node. The Storage Expansion Node provides storage capacity for
Network Attach Storage (NAS) workloads, which provides flexible storage to match capacity, performance, and reliability needs.
The following figure shows the IBM Flex System Storage Expansion Node attached to a compute node.
Figure 4. IBM Flex System Storage Expansion Node (right) attached to a compute node (left)
The ordering information for the Storage Expansion Node is shown in the following table.
Table 10. Ordering part number and feature code
Part number Feature code Description
68Y8588 A3JF IBM Flex System Storage Expansion Node
Maximum supported
1
The Storage Expansion Node has the following features:
Connects directly to supported compute nodes via a PCIe 3.0 interface to the compute node's expansion connector (see Figure 3).
Supports 12 hot-swap 2.5-inch drive, accessible via a sliding tray.
Supports 6 Gbps SAS and SATA drives, both HDDs and SSDs.
Based on an LSI SAS2208 6 Gbps RAID on Chip (ROC) controller.
Supports RAID 0, 1, 5, 10, and 50 as standard. JBOD also supported. Optional RAID 6 and 60 with a
Features on Demand upgrade.
Optional 512 MB or 1 GB cache with cache-to-flash super capacitor offload.
Note
: The use of the Storage Expansion Node requires that the x240 M5 Compute Node have both processors installed.
For more information, see the IBM Redbooks Product Guide on the IBM Flex System Storage Expansion
Node, which is available at this website: http://www.redbooks.ibm.com/abstracts/tips0914.html?Open
IBM Flex System x240 M5 Product Guide 18
Internal tape drives
The server does not support an internal tape drive. However, it can be attached to external tape drives by using Fibre Channel connectivity.
Optical drives
The server does not support an internal optical drive option. However, you can connect an external USB optical drive, such as the IBM and Lenovo part number 73P4515 or 73P4516, or use the remote media feature of the IMMv2 and the Chassis Management Module.
Note
: The USB port on the compute nodes supplies up to 0.5 A at 5 V. For devices that require more power, another power source is required.
EN4172 2-port 10Gb Ethernet Adapter
Some models of the x240 M5 (those with a model of the form 9532-x4x) include the IBM Flex System
EN4172 2-port 10Gb Ethernet Adapter installed in slot 1. Table 2 lists the models with this adapter standard. These models require that a compatible Ethernet switch be installed in I/O module bays 1 and 2 of the chassis.
The EN4172 2-port 10Gb Ethernet Adapter includes the following features:
Two-port 10 Gb Ethernet adapter
Single ASIC controller that uses the QLogic BCM57840 ASIC
PCI Express 3.0 x8 host interface
B and 10 Gb auto-negotiation)
Full line-rate performance
Supports vNIC - Switch Independent Mode
For more information about this adapter, see the IBM Redbooks Product Guide, available from: http://www.redbooks.ibm.com/abstracts/tips1087.html?Open
CN4052 2-port 10Gb Virtual Fabric Adapter
Some models of the x240 M5 (those with a model of the form 9532-x6x) include the IBM Flex System
CN4052 2-port 10Gb Virtual Fabric Adapter installed in slot 1. Table 2 lists the models with this adapter standard. These models require that a compatible Ethernet switch be installed in I/O module bays 1 and 2 of the chassis.
The CN4052 2-port 10Gb Virtual Fabric Adapter includes the following features:
Two-port 10 Gb Ethernet adapter.
Optional support for FCoE and iSCSI via an Features on Demand license upgrade.
Single ASIC controller that uses the Emulex XE104 design.
PCIe Express 3.0 x8 host interface (8 GT/s).
Connection to 1 Gb or 10 Gb data center infrastructure (1 Gb and 10 Gb auto-negotiation) .
Full line-rate performance.
Supports NIC virtualization (vNIC) up to four virtual ports per physical port. Supports IBM Fabric
Mode, Switch Independent Mode, and Unified Fabric Port Mode.
For more information about this adapter, see the IBM Redbooks Product Guide, available from: http://www.redbooks.ibm.com/abstracts/tips1164.html?Open
IBM Flex System x240 M5 Product Guide 19
I/O expansion options
The x240 M5 has two I/O expansion connectors for attaching I/O adapter cards. There is a third expansion connector that is designed to connect an expansion node, such as the PCIe Expansion Node.
The I/O expansion connectors are a high-density, 216-pin PCIe connector. Installing I/O adapter cards allows the server to connect with switch modules in the IBM Flex System Enterprise Chassis. Each slot has a PCI Express 3.0 x16 host interface and both slots support the same form-factor adapters.
The following figure shows the location of the I/O expansion connectors.
Figure 5. Location of the I/O adapter slots in the IBM Flex System x240 M5 Compute Node
All I/O adapters are the same shape and can be used in any available slot.. A compatible switch or pass-through module must be installed in the corresponding I/O bays in the chassis, as indicated in the following table. Installing two switches means that all ports of the adapter are enabled, which improves performance and network availability.
Table 11. Adapter to I/O bay correspondence
I/O adapter slot in the server
Slot 1
Slot 2
Port on the adapter
Port 1
Corresponding I/O module bay in the chassis
Module bay 1
Port 2 Module bay 2
Port 3 (for 4-port cards) Module bay 1
Port 4 (for 4-port cards) Module bay 2
Port 1 Module bay 3
Port 2 Module bay 4
Port 3 (for 4-port cards) Module bay 3
Port 4 (for 4-port cards) Module bay 4
IBM Flex System x240 M5 Product Guide 20
The following figure shows the location of the switch bays in the IBM Flex System Enterprise Chassis.
Figure 6. Location of the switch bays in the IBM Flex System Enterprise Chassis
The following figure shows how two-port adapters are connected to switches that are installed in the chassis.
Figure 7. Logical layout of the interconnects between I/O adapters and I/O modules
IBM Flex System x240 M5 Product Guide 21
IBM Flex System PCIe Expansion Node
The x240 M5 supports the attachment of the IBM Flex System PCIe Expansion Node. By using the IBM
Flex System PCIe Expansion Node, more PCI Express cards can be attached, such as High IOPS SSD adatpers, fabric mezzanine cards, and next-generation graphics processing units (GPU) to supported IBM
Flex System compute nodes. This capability is ideal for many applications that require high performance
I/O, special telecommunications network interfaces, or hardware acceleration that uses a PCI Express card. The PCIe Expansion Node supports up to four PCIe 2.0 adapters and two more Flex System expansion adapters.
The PCIe Expansion Node is attached to a Flex System compute node, as shown in the following figure.
Figure 8. PCIe Expansion Node attached to a compute node
The ordering information for the PCIe Expansion Node is shown in the following table.
Table 12. Ordering part number and feature code
Part number
81Y8983
Feature code
A1BV
Description
IBM Flex System PCIe Expansion Node
Maximum supported
1
The PCIe Expansion Node has the following features:
Support for up to four standard PCIe 2.0 adapters:
Two PCIe 2.0 x16 slots that support full-length, full-height adapters
Two PCIe 2.0 x8 slots that support half-length, low-profile adapters
Support for PCIe 3.0 adapters by operating them in PCIe 2.0 mode
Support for one full-length, full-height double-wide adapter (that uses the space of the two full-length, full-height adapter slots)
Support for PCIe cards with higher power requirements; a single adapter card (up to 225W) or to two adapters (up to 150W each)
Two Flex System I/O expansion connectors to further expand the I/O capability of the attached compute node
Note
: The use of the PCIe Expansion Node requires that the x240 M5 Compute Node have both processors installed.
For more information, see the IBM Redbooks Product Guide on the IBM Flex System PCIe Expansion
Node, which is available at this website: http://www.redbooks.ibm.com/abstracts/tips0906.html?Open
IBM Flex System x240 M5 Product Guide 22
Network adapters
The following table lists the supported network adapters and upgrades. Adapters can be installed in either slot. However, compatible switches must be installed in the corresponding bays of the chassis. All adapters can also be installed in the PCIe Expansion Node. The "Maximum supported" column in the table indicates the number of adapter that can be installed in the server and in the PCIe Expansion Node
(PEN).
Table 13. Network adapters
Part number
Feature code
Description Number of ports
Maximum supported
(x240 M5* /
PEN)
40 Gb Ethernet
90Y3482 A3HK
10 Gb Ethernet
88Y5920 A4K3
00JY800 A5RP
00JY804 A5RV
00Y3306 A4K2
90Y3558 A1R0
94Y5160 A4R6
94Y5164 A4R9
IBM Flex System EN6132 2-port 40Gb Ethernet Adapter
IBM Flex System CN4022 2-port 10Gb Converged Adapter
IBM Flex System CN4052 2-port 10Gb Virtual Fabric Adapter
IBM Flex System CN4052 Virtual Fabric Adapter SW Upgrade
(FoD) (License to enable FCoE and iSCSI on 00JY800)
IBM Flex System CN4054R 10Gb Virtual Fabric Adapters
IBM Flex System CN4054 Virtual Fabric Adapter (SW Upgrade)
(License to enable FCoE and iSCSI on 00Y3306)
IBM Flex System CN4058S 8-port 10Gb Virtual Fabric Adapter
IBM Flex System CN4058S Virtual Fabric Adapter SW Upgrade
(FoD) (License to enable FCoE and iSCSI on 94Y5160)
2
2
2
2 / None
2 / 2
2 / 2
License 2 / 2
4
License
8
License
2 / 2
2 / 2
2 / 2
2 / 2
90Y3466 A1QY
00AG530 A5RN
1 Gb Ethernet
49Y7900 A10Y
IBM Flex System EN4132 2-port 10Gb Ethernet Adapter
IBM Flex System EN4172 2-port 10Gb Ethernet Adapter
2
2
2 / 2
2 / 2
IBM Flex System EN2024 4-port 1 Gb Ethernet Adapter 4 2 / 2
InfiniBand
90Y3454 A1QZ IBM Flex System IB6132 2-port FDR InfiniBand Adapter 2 2 / 2
* For x4x and x6x models (where an Ethernet adapter is standard in slot 1), only one extra adapter can be installed in the compute node.
For more information about adapter-to-switch compatibility, see the IBM Flex System Interoperability
Guide, which is available at this website: http://www.redbooks.ibm.com/fsig
IBM Flex System x240 M5 Product Guide 23
Storage host bus adapters
The following table lists storage HBAs that are supported by the x240 M5 server, both internally in the compute node and in the PCIe Expansion Node.
Table 14. Storage adapters
Part number
Feature code
Description Number of ports
Maximum supported
(x240 M5* /
PEN)
Fibre Channel
88Y6370
95Y2391
69Y1938
A1BP
95Y2386 A45R
A45S
69Y1942 A1BQ
A1BM
95Y2375 A2N5
IBM Flex System FC5022 2-port 16Gb FC Adapter
IBM Flex System FC5052 2-port 16Gb FC Adapter
IBM Flex System FC5054 4-port 16Gb FC Adapter
IBM Flex System FC5172 2-port 16Gb FC Adapter
IBM Flex System FC3172 2-port 8Gb FC Adapter
IBM Flex System FC3052 2-port 8Gb FC Adapter
2
2
4
2
2
2
2 / 2
2 / 2
2 / 2
2 / 2
2 / 2
2 / 2
* For x4x and x6x models (where an Ethernet adapter is standard in slot 1), only one extra adapter can be installed in the compute node.
For more information about adapter-to-switch compatibility, see the IBM Flex System Interoperability
Guide, which is available at this website: http://www.redbooks.ibm.com/fsig
PCIe SSD adapters
The compute node supports the High IOPS SSD adapters that are listed in the following table. These adapters are installed in an attached PCIe Expansion Node.
Table 15. SSD adapters
Part
number
46C9078
46C9081
90Y4377
90Y4397
Feature code
A3J3
A3J4
A3DY
A3DZ
Description
IBM 365GB High IOPS MLC Mono Adapter (low-profile adapter) 4
IBM 785GB High IOPS MLC Mono Adapter (low-profile adapter) 4
Maximum supported
IBM 1.2TB High IOPS MLC Mono Adapter (low-profile adapter)
IBM 2.4TB High IOPS MLC Duo Adapter (full-height adapter)
2
2
For more information about these adapters, see the IBM Redbooks Product Guide for the IBM High IOPS
MLC Adapters, which is available at this website: http://www.redbooks.ibm.com/abstracts/tips0907.html
IBM Flex System x240 M5 Product Guide 24
GPU and Crypto adapters
The compute node supports the GPU and Crypto adapters that are listed in the following table.
Note
: These adapters are installed in an attached PCIe Expansion Node.
Table 16. GPU and Crypto adapters
Part number
94Y5960
47C2120
47C2121
47C2119
Feature code
A1R4
A4F1
A4F2
A4F3
Description
NVIDIA Tesla M2090 (full-height adapter)
NVIDIA GRID K1 for IBM Flex System PCIe Expansion Node
NVIDIA GRID K2 for IBM Flex System PCIe Expansion Node
NVIDIA Tesla K20 for IBM Flex System PCIe Expansion Node
Maximum supported
1*‡
1†‡
1†‡
1†‡
47C2137 A5HD NVIDIA Tesla K40 for IBM Flex System PCIe Expansion Node 1†‡
47C2122 A4F4 Intel Xeon Phi 5110P for IBM Flex System PCIe Expansion Node 1†‡
* If the NVIDIA Tesla M2090 is installed in the Expansion Node, then an adapter cannot be installed in the other full-height slot. If installed, only this adapter is supported in the expansion node. No other PCIe adapters may be selected.
† The K1, K2, K20, K40 and 5110P adapters are double-wide cards and occupy the two full-height PCIe slots. If installed, the adjacent slot is unavailable, however adapters can be installed in the two low-profile slots.
‡ NVIDIA GRID Kx and Tesla Kxx GPUs supported only when the x240 M5 has 1 TB or less memory installed.
Power supplies
Server power is derived from the power supplies that are installed in the chassis. There are no server options regarding power supplies.
IBM Flex System x240 M5 Product Guide 25
Integrated virtualization
The x240 M5 supports the VMware vSphere (ESXi) hypervisor on one or two SD cards with the optional
SD Media Adapter for System x. This adapter is installed in a dedicated slot under I/O Adapter slot 1, as shown in the following figure.
Figure 9. SD Media Adapter for System x
When only one SD card is installed in the adapter, you can create up to 16 volumes, each of which is presented to UEFI as a bootable device. When two SD Media cards are inserted, volumes can be mirrored (RAID 1) across both cards, up to a total of eight mirrored volumes. The use of mirrored volumes improves system availability because the server remains operational, even if one SD card fails.
The RAID functionality is handled internally by the SD Media Adapter.
The following table shows the available options. The table also indicates whether the option includes the
SD Media RAID Adapter and how many SD cards are included.
Table 17. Virtualization options
Part number
00ML706
00ML700
None**
None**
None**
Feature code
A5TJ
AS2V
AS4B
AS4C
ASCG
Description Includes
Adapter
Yes SD Media Adapter for Systems x
(Option 00ML706 includes 2 blank 32GB SD cards)
Blank 32GB SD Media for System x
RAID Adapter for SD Media w/ VMware ESXi 5.1 U2 (2 SD
Media, RAIDed)
No
Yes
RAID Adapter for SD Media w/ VMware ESXi 5.5 U2 (2 SD
Media, RAIDed)
Yes
RAID Adapter for SD Media w/ VMware ESXi 5.1 U2 (1 SD
Media)
Yes
Includes
Media
Yes (2)*
Yes (2)
Yes (2)
Yes (2)
Yes (1)
None** ASCH RAID Adapter for SD Media w/ VMware ESXi 5.5 U2 (1 SD
Media)
Yes Yes (1)
* Option 00ML706 includes two 32GB SD cards; however, for CTO orders, feature code A5TJ does not include SD media and the 32GB cards and VMware vSphere preload must be selected separately.
** CTO only.
IBM Flex System x240 M5 Product Guide 26
Light path diagnostics
For quick problem determination when it is physically at the server, the x240 M5 offers the following three-step guided path:
1.
2.
3.
The Fault LED on the front panel.
The light path diagnostics panel, as shown in the following figure.
LEDs next to key components on the system board.
The x240 M5 light path diagnostics panel is inside the server between the two processors, as shown in the following figure.
Figure 10. Location of x240 M5 light path diagnostics panel
To illuminate the light path diagnostics LEDs, power off the compute node, slide it out of the chassis, and press the power button. The power button doubles as the light path diagnostics reminder button when the server is removed from the chassis.
The meanings of the LEDs in the light path diagnostics panel are listed in the following table.
Table 18. Light path diagnostic panel LEDs
LED
LP
SYS BRD
NMI
SEE EXP
MIS
TEMP
MEM
Meaning
The light path diagnostics panel is operational.
A system board error is detected.
A non-maskable interrupt (NMI) occurred.
A fault is detected in the adjacent expansion unit (if installed).
A mismatch occurred between the processors, DIMMs, or HDDs within the configuration as reported by POST.
An over-temperature condition occurred that was critical enough to shut down the server.
A memory fault occurred. The corresponding DIMM error LEDs on the system board are also lit.
IBM Flex System x240 M5 Product Guide 27
Remote management
The server contains an IBM Integrated Management Module II (IMM2), which interfaces with the advanced management module in the chassis. The combination of these modules provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, LEDs on the system board are lit to help you diagnose the problem, the error is recorded in the event log, and you are alerted to the problem. A virtual presence capability comes standard for remote server management.
Remote server management is provided through the following industry-standard interfaces:
Intelligent Platform Management Interface (IPMI) Version 2.0
Simple Network Management Protocol (SNMP) Version 3
Common Information Model (CIM)
Web browser
The server also supports virtual media and remote control features, which provide the following functions:
Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state.
Remotely accessing the server by using the keyboard and mouse from a remote client.
Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping
ISO and diskette image files as virtual drives that are available for use by the server.
Uploading a diskette image to the IMM2 memory and mapping it to the server as a virtual drive.
Capturing blue-screen errors.
Supported operating systems
The server supports the following operating systems:
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Red Hat Enterprise Linux 6 Server x64 Edition
Red Hat Enterprise Linux 7
SUSE LINUX Enterprise Server 11 for AMD64/EM64T
SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
VMware vSphere 5.1 (ESXi)
VMware vSphere 5.5 (ESXi)
Note
: Support by some of these operating system versions is available after the date of initial availability.
For more information about the specific versions and service levels that are supported and any other prerequisites, see the following IBM ServerProven® website: http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml
IBM Flex System x240 M5 Product Guide 28
Physical specifications
The server features the following dimensions and weight (approximate):
Height: 51 mm (2.0 in)
Depth: 493 mm (19.4 in)
Width: 215 mm (8.5 in)
Maximum weight: 7.1 kg (15.6 lb)
The server features the following shipping dimensions and weight (approximate):
Height: 197 mm (7.8 in)
Depth: 603 mm (23.7 in)
Width: 430 mm (16.9 in)
Weight: 8 kg (17.6 lb)
Supported environment
The IBM Flex System x240 M5 compute node complies with ASHRAE Class A3 specifications.
The following Power on operating environment is supported:
Temperature: 5 - 40 °C (41 - 104 °F)
Humidity, non-condensing: -12 °C dew point (10.4 °F) and 8 - 85% relative humidity
Maximum dew point: 24 °C (75 °F)
Maximum altitude: 3048 m (10,000 ft)
Maximum rate of temperature change: 5 °C/hr (41 °F/hr)
The following Power off operating environment is supported:
Temperature: 5 - 45 °C (41 - 113 °F)
Relative humidity: 8 - 85%
Maximum dew point: 27 °C (80.6 °F)
The following Storage (non-operating) operating environment is supported:
Temperature: 1 - 60 °C (33.8 - 140 °F)
Altitude: 3050 m (10,006 ft)
Relative humidity: 5 - 80%
Maximum dew point: 29 °C (84.2°F)
The following Shipment (non-operating) environment is supported:
Temperature: -40 - 60 °C (-40 - 140 °F)
Altitude: 10,700 m (35,105 ft)
Relative humidity: 5 - 100%
Maximum dew point: 29 °C (84.2 °F)
IBM Flex System x240 M5 Product Guide 29
Warranty options
The IBM Flex System x240 M5 Compute Node has a three-year, on-site warranty with 9x5 next-business-day terms. IBM offers the warranty service upgrades through IBM ServicePac, which is a series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
IBM ServicePac offerings are country-specific. That is, each country might have its own service types, service levels, response times, and terms and conditions. Not all covered types of ServicePac might be available in a particular country. For more information about IBM ServicePac offerings that are available in your country, see the IBM ServicePac Product Selector at this website: https://www-304.ibm.com/sales/gss/download/spst/servicepac
The following table describes the warranty service definitions.
Table 19. Warranty service definitions
Term
IBM on-site repair (IOR)
Description
A service technician travels to the server's location for equipment repair.
24x7x2 hour A service technician is scheduled to arrive at your customer’s location within two hours after remote problem determination is completed. We provide 24-hour service, every day, including IBM holidays.
24x7x4 hour A service technician is scheduled to arrive at your customer’s location within four hours after remote problem determination is completed. We provide 24-hour service, every day, including IBM holidays.
9x5x4 hour
9x5 next business day
A service technician is scheduled to arrive at your customer’s location on the business day after we receive your call, following remote problem determination. We provide service 8:00 a.m. - 5:00 p.m. in the customer's local time zone, Monday - Friday, excluding IBM holidays.
A service technician is scheduled to arrive at your customer’s location within four business hours after remote problem determination is completed. We provide service 8:00 a.m. - 5:00 p.m. in the customer's local time zone, Monday - Friday, excluding IBM holidays. If after 1:00 p.m. it is determined that on-site service is required, the customer can expect the service technician to arrive the morning of the following business day. For noncritical service requests, a service technician arrives by the end of the following business day.
The following types of IBM ServicePacs are available:
Warranty and maintenance service upgrades:
One, two, three, four, or five years of 9x5 or 24x7 service coverage
On-site repair from the next business day to four or two hours
One or two years of warranty extension
IBM Flex System x240 M5 Product Guide 30
Remote technical support services:
One or three years with 24x7 coverage (severity 1) or 9 - 5 next business day for all severity levels
Installation and startup support for IBM System x® servers
Remote technical support for IBM System x servers
Software support - Support Line:
Microsoft or Linux software
VMware
IBM Systems Director
Regulatory compliance
The server conforms to the following standards:
ASHRAE Class A3
FCC - Verified to comply with Part 15 of the FCC Rules Class A
Canada ICES-004, issue 3 Class A
UL/IEC 60950-1
CSA C22.2 No. 60950-1
Japan VCCI, Class A
IEC 60950-1 (CB Certificate and CB Test Report)
Taiwan BSMI CNS13438, Class A; CNS14336
Australia/New Zealand AS/NZS CISPR 22, Class A
Korea KN22, Class A, KN24
IEC 60950-1 (CB Certificate and CB Test Report)
CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2,
EN61000-3-3)
TUV-GS (EN60950-1/IEC 60950-1, EK1-ITB2000)
IBM Flex System x240 M5 Product Guide 31
Related publications and links
For more information, see the following resources:
IBM Flex System x240 M5 Compute Node product page http://ibm.com/systems/flex/compute-node/x86/bto/x240_m5/
IBM Flex System Information Center http://publib.boulder.ibm.com/infocenter/flexsys/information/index.jsp
ServerProven for IBM Flex System http://ibm.com/systems/info/x86servers/serverproven/compat/us/flexsystems.html
ServerProven compatibility page for operating system support http://ibm.com/systems/info/x86servers/serverproven/compat/us/nos/flexmatrix.shtml
IBM Redbooks® Product Guides for IBM Flex System servers and options http://www.redbooks.ibm.com/Redbooks.nsf/portals/flexsystem?Open&page=pgbycat
IBM Flex System Interoperability Guide http://www.redbooks.ibm.com/fsig
Configuration and Option Guide http://www.ibm.com/systems/xbc/cog/ xREF - IBM System x Reference Sheets http://www.redbooks.ibm.com/xref
IBM System x Support Portal http://ibm.com/support/entry/portal/
IBM System Storage® Interoperation Center http://www.ibm.com/systems/support/storage/ssic
IBM Flex System x240 M5 Product Guide 32
Notices
Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
1009 Think Place - Building One
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.
The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.
© Copyright Lenovo 2014. All rights reserved.
IBM Flex System x240 M5 Product Guide 33
This document was created or updated on November 6, 2014.
Send us your comments in one of the following ways:
Use the online Contact us review form found at:
ibm.com
/redbooks
Send your comments in an e-mail to: [email protected]
This document is available online at http://www.ibm.com/redbooks/abstracts/tips1199.html
.
Trademarks
Lenovo, the Lenovo logo and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. These and other Lenovo trademarked terms are marked on their first occurrence in this information with the appropriate symbol (® or ™), indicating US registered or common law trademarks owned by Lenovo at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of Lenovo trademarks is available on the Web at http://www.lenovo.com/legal/copytrade.html
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Flex System™
For Those Who Do™
Lenovo®
Lenovo(logo)®
ServeRAID™
ServerProven®
System x®
TruDDR4™ vNIC™
The following terms are trademarks of other companies:
Intel, Intel Xeon, Intel logo, Intel Inside logo, and Intel Centrino logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
Linux is a trademark of Linus Torvalds in the United States, other countries, or both.
Microsoft, Windows, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
IBM Flex System x240 M5 Product Guide 34
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 IBM Flex System x240 M5 Product Guide
- 1 Did you know?
- 2 Key features
- 5 Locations of key components and connectors
- 6 Standard specifications
- 8 Standard models
- 10 Chassis support
- 11 Processor options
- 12 Memory options
- 14 Internal storage
- 15 Internal drive options
- 18 IBM Flex System Storage Expansion Node
- 19 Internal tape drives
- 19 Optical drives
- 19 EN4172 2-port 10Gb Ethernet Adapter
- 19 CN4052 2-port 10Gb Virtual Fabric Adapter
- 20 I/O expansion options
- 22 IBM Flex System PCIe Expansion Node
- 23 Network adapters
- 24 Storage host bus adapters
- 24 PCIe SSD adapters
- 25 GPU and Crypto adapters
- 25 Power supplies
- 26 Integrated virtualization
- 27 Light path diagnostics
- 28 Remote management
- 28 Supported operating systems
- 29 Physical specifications
- 29 Supported environment
- 30 Warranty options
- 31 Regulatory compliance
- 32 Related publications and links
- 33 Notices
- 34 Trademarks