Mitsubishi GX IEC Developer software Reference Manual
Pubblicità
Pubblicità
• SAFETY PRECAUTIONS •
(Always read these instructions before using this equipment.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.
The instructions given in this manual are concerned with this product. For the safety instructions of the programmable controller system, please read the CPU module user's manual.
In this manual, the safety instructions are ranked as "DANGER" and "CAUTION".
!
DANGER
!
CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Note that the
!
CAUTION level may lead to a serious consequence according to the circumstances.
Always follow the instructions of both levels because they are important to personal safety.
Please save this manual to make it accessible when required and always forward it to the end user.
[Design Instructions]
!
DANGER
• For data change, program change, and status control made to the PLC which is running from a
Personal computer, configure the interlock circuit externally so that the system safety is ensured. The action to be taken for the system at the occurrence of communication errors caused by such as loose cable connection must be determined for online operation of PLC from
Personal computers.
!
CAUTION
• Be sure to read the manual careful and exercise an appropriate amount of caution connecting to
PLC CPU and performing online operations (PLC CPU program change during RUN, forced input/output operation, RUN-STOP or other operation condition changes, remote control operation) while the personal computer is operating.
Regarding the PLC CPU program change during RUN (Online change), the program may be corrupted or have other problems depending on operation conditions. Exercise the appropriate amount of caution with regard to the Caution points in section 8.4.3.
• Please refer to the manual of each module for online module change and swap module during run, since there is restriction on the exchangeable module.
The texts, illustrations, diagrams and examples in this manual are only intended as aids to help explain the functioning, operation, use and programming of the GX IEC Developer IEC programming and documentation system.
For using and usage of this software only the user his own is responsible.
If you have any questions regarding the installation and operation of the software described in this manual, please do not hesitate to contact your sales office or one of your Mitsubishi distribution partners.
You can also obtain information and answers to frequently asked questions from our Mitsubishi website under www.mitsubishi-automation.com.
The GX IEC Developer software is supplied under a legal license agreement and may only be used and copied subject to the terms of this
License Agreement.
No part of this manual may be reproduced, copied, stored in any kind of information retrieval system or distributed without the prior express written consent of MITSUBISHI ELECTRIC.
MITSUBISHI ELECTRIC reserves the right to change the specifications of its products and/or the contents of this manual at any time and without prior notice.
The IEC 61131.1 standard cited in this manual is available from the publishers Beuth Verlag in Berlin (Germany).
© October 2008
Reference Manual for
MELSOFT GX IEC Developer
Art. No.: 43597
B
C
Version
A 03/1995 ME
05/1996 ME
07/1997 ME
Changes / Additions / Corrections
First issue
Software update
Software update
J
K
I
H
D
E
01/1998 ME Software update
08/2000 pdp-rs Update to software version 2.40
F 06/2001 pdp-rs Update to software version 4.00
G 05/2002 pdp-rs Update to software version 5.00
09/2003 pdp-ow
10/2004 pdp-ow
09/2005 pdp-ow
12/2006 pdp-ow
Update to software version 6.00
Update to software version 6.10
Update to software version 7.00
Update to software version 7.01
L 09/2007 pdp-ow Update to software version 7.02
M 10/2008 pdp-ow Update to software version 7.03
NOTE
Example
Typographic Conventions
Use of notes
Notes containing important information are clearly identified as follows:
Note text
Use of examples
Examples containing important information are clearly identified as follows:
Example text
쑶
Numbering in figures and illustrations
Reference numbers in figures and illustrations are shown with white numbers in a black circle and the corresponding explanations shown beneath the illustrations are identified with the same numbers, like this:
� � � �
Procedures
In some cases the setup, operation, maintenance and other instructions are explained with numbered procedures. The individual steps of these procedures are numbered in ascending order with black numbers in a white circle, and they must be performed in the exact order shown:
햲 Text
햳 Text
햴 Text
Footnotes in tables
Footnote characters in tables are printed in superscript and the corresponding footnotes shown beneath the table are identified by the same characters, also in superscript.
If a table contains more than one footnote, they are all listed below the table and numbered in ascending order with black numbers in a white circle, like this:
햲
Text
햳
Text
햴
Text
Character formatting and orientation aids
Menu names, menu commands, submenu commands, and dialogue box options are printed in
boldface type. Examples: The menu item New in the menu Project or the options PLC inter-
face and Computer Link in the dialogue box Transfer-Setup.
Please keep this manual in a place where it is always available for the users.
Contents
Contents
GX IEC Developer Reference Manual IX
Contents
2C series controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
2NC series controllers . . . . . . . . . . . . . . . 2-56
XP Home Edition is used . . . . . . . . . . . . 2-73
X
MITSUBISHI ELECTRIC
Contents
GX IEC Developer Reference Manual XI
Contents
XII
MITSUBISHI ELECTRIC
Contents
GX IEC Developer Reference Manual XIII
Contents
XIV
MITSUBISHI ELECTRIC
Contents
GX IEC Developer Reference Manual XV
Contents
XVI
MITSUBISHI ELECTRIC
Contents
8 Compiling and Downloading Programs
GX IEC Developer Reference Manual XVII
Contents
Comparing the programs in the PLC CPU and GX IEC Developer . . . . . . . . . . . . . . . . . . 8-104
Transfer from Program Cache to Program Memory after Online Program (Ex)Change. . . 8-115
9 Diagnostics Functions and Online Operation
XVIII
MITSUBISHI ELECTRIC
Contents
GX IEC Developer Reference Manual XIX
Contents
10 Working with Projects of Version 6.11 and before
11 Support of other Applications
XX
MITSUBISHI ELECTRIC
Contents
GX IEC Developer Reference Manual XXI
Contents
XXII
MITSUBISHI ELECTRIC
Introduction
1 Introduction
1.1
This manual …
This manual …
… is not designed to be read from cover to cover. It is organised so that it can be used as a reference work in which you can find detailed explanations of all the menus and menu commands in GX IEC Developer when you need them. However, the Reference Manual is not based directly on the menu structure of GX IEC Developer, but rather on the central elements of IEC Standard 61131-3 such as Projects, Objects, Variables, Program Organisation Units and Programming Languages. The menus and all menu commands and options are listed in
the Appendix F of this manual.
1.2
1.3
1.4
1.5
The Beginner's Manual…
… is the ideal aid for getting acquainted with the basic terms and concepts of the new IEC
61131-3 standard. This manual teaches you how to use GX IEC Developer in easy steps, with a sample program that provides a practical illustration of the most important operations.
If you are not yet familiar with Windows…
… please at least read the Windows Fundamentals section in the Windows User's Guide or work through the exercises of the online Windows tutorial (accessible in the Program Manager).
This will give you the information and skills you need for using the elements of Windows that are the same in all application programs.
If you are not yet completely familiar with the IEC
61131-3 standard …
… please read the chapter on the IEC 61131-3 standard in the Beginner's Manual. This chapter explains the basic principles of this industry standard, together with the most important new terms you need to know. A glossary of all the terms used is provided at the end of this Reference Manual.
If you are already acquainted with IEC 61131-3 and want to get to work right away …
… you will find the basic instructions you need to be able to produce immediate results in the
‘Getting Started' chapter in the Beginner's Manual. This chapter tells you how to perform all the basic GX IEC Developer operations, from creating new projects to downloading your finished programs to the PLC (programmable controller).
GX IEC Developer Reference Manual 1 – 1
If you need more information on programmable controllers …
1.6
Introduction
If you need more information on programmable controllers …
… please refer to the documentation provided with the hardware components of your system.
1.7
1.8
If you need help on programming instructions when you are developing your programs …
… use the GX IEC Developer online help system. This provides direct access to brief explanations of all programming instructions, together with their syntax, parameters and operands. A
list of all IEC and MELSEC programming instructions is also provided in the Appendix E of this
manual. More detailed descriptions and sample programs can be found in the programming manuals of the individual PLCs.
If you get stuck …
… in what looks like an insoluble problem or if you have questions about GX IEC Developer or the connected PLC configuration, please first refer to the manuals. Use the detailed index provided in this Reference Manual. Answers to many of your questions can also be found in
GX IEC Developer‘s context-sensitive online help system, which can always be accessed by pressing
. Please also make use of the Search command in the Help menu.
If you fail to find an answer to your particular question in any of these places you can also obtain help from your local MITSUBISHI ELECTRIC representative. Alternatively, you can call us directly at the MITSUBISHI ELECTRIC European headquarters in Ratingen, Germany. The addresses and phone numbers are listed on the rear of all PLC manuals.
1 – 2
MITSUBISHI ELECTRIC
Installation
2 Installation
2.1
2.1.1
2.1.2
Hardware requirements
Hardware requirements
Recommended hardware configuration
쎲 Pentium II 350 processor or above
쎲 64 MB RAM (Microsoft Windows
약
128 MB RAM (Microsoft Windows
약
2000)
XP)
1024 MB RAM (Microsoft Windows Vista
약
)
쎲 Serial interface (RS-232)
쎲 USB port
쎲 Hard disk with at least 200 MB free space
쎲 CD/DVD-ROM drive
쎲 17" (43 cm) VGA monitor (1024 x 768 pixels)
Software Requirements
GX IEC Developer is a 32-bit product. The following operating systems are supported:
쎲 Microsoft Windows
약
2000 Professional (with ServicePack 2 or higher)
쎲 Microsoft Windows
약
XP Professional (up to ServicePack 3)
쎲 Microsoft Windows
약
XP Home Edition (up to ServicePack 3)
쎲 Microsoft Windows Vista
약
(32-Bit) (up to ServicePack 1)
Versions of Microsoft Windows which are based on double-byte character sets
(e. g. Japanese) are not supported.
GX IEC Developer Reference Manual 2 – 1
Hardware requirements Installation
2.1.3
NOTE
Compatibility
File based compatibility with former versions
쎲 GX IEC Developer 7.03 can open project databases (*.pro file) of MM+ 2.1, 2.30a, 2.31,
2.31a, 2.32, 2.40, 2.40a, 2.50, 3.00, GX IEC Developer 4.00, 5.00, 5.01, 5.02, 6.00, 6.01,
6.10, 6.11, 7.00, 7.01 and 7.02, but these versions can not open GX IEC Developer 7.03
project databases.
Exception: GX IEC Developer 7.03 can not open project databases (*.pro file) of MM+ 2.1,
2.30a, 2.31, 2.31a, 2.32, 2.40, 2.40a, 2.50 and 3.00 with Microsoft Windows
약
XP and
Microsoft Windows Vista
약
.
쎲 GX IEC Developer 7.03 can not open project databases (*.pro file) of MM+ 2.41 and vice versa.
쎲 GX IEC Developer 7.03 can import projects, which have been exported (*.asc file) by
MM+ 2.1, 2.30a, 2.31, 2.31a, 2.32, 2.40, 2.40a, 2.41, 2.50, 3.00, GX IEC Developer 4.00,
5.00, 5.01, 5.02, 6.00, 6.01, 6.10, 6.11, 7.00, 7.01 and 7.02, but these versions cannot import *.asc exports of GX IEC Developer 7.03.
쎲 GX IEC Developer 7.03 can open library files (*.lib file) of GX IEC Developer 4.00, 5.00,
6 . 0 0 , 6 . 1 0 , 6 . 1 1 , 7 . 0 0 , 7 . 0 1 a n d 7 . 0 2 , bu t t h e s e ve r s i o n s c a n n o t o p e n
GX IEC Developer 7.03 library files.
PLC project based compatibility with former versions
It is possible, that the generated code of GX IEC Developer 7.03 is different to the generated code of a former version of GX IEC Developer. This could result in the following facts:
쎲 An online change can fail, if the project was not downloaded with GX IEC Developer 7.03.
쎲 The functionality to verify the generated code with the program on the PLC can show differences.
The reason for the differences are internal changes in the code generator which result from the implementation of new features in GX IEC Developer 7.03.
Please also see section 2.9.1, Code Generation.
2 – 2
MITSUBISHI ELECTRIC
Installation
2.1.4
Hardware requirements
Compatibility with other programming software for MELSEC PLCs:
쎲 GX IEC Developer 7.03 can import MELSEC MEDOC/DOS print files (*.tmp) of the versions 1.64b/c, 2.20 and 2.30.
쎲 GX IEC Developer 7.03 generally can not upload parameters and programs from Q and
QnA/S CPUs, which are generated by GX Developer or GPPQ.
쎲 GX IEC Developer 7.03 can upload only programs from Q and QnA/S CPUs which are generated according to the limitations of GX IEC Developer 7.03 compared to the Q and
QnA/S features (only one program file MAIN.QPG).
쎲 GX IEC Developer 7.03 can upload programs from A CPUs which are generated with
GX Developer or GPPA.
쎲 GX IEC Developer 7.03 can not open project databases from GX Developer, GPPQ or
GPPA.
There is currently no direct possibility to exchange projects between GX IEC Developer 7.03
and GX Developer, GPPQ or GPPA.
Copyright
E
WARNING:
This software is protected by copyright. By opening the distribution CD-ROM package you automatically accept the terms and conditions of the License Agreement. You are only permitted to make one single copy of the original distribution disk for your own backup and archiving purposes.
2.1.5
Filling out the registration card
You are only entitled to full technical support from MITSUBISHI ELECTRIC if you fill out and return the enclosed registration card – don't forget to include your serial number! You will then also receive information on updates and new versions of GX IEC Developer.
GX IEC Developer Reference Manual 2 – 3
Installing GX IEC Developer
2.2
2.2.1
Installation
Installing GX IEC Developer
During this procedure the installation program will create a directory on your hard disk, into which all the GX IEC Developer files will be copied.
Installing GX IEC Developer on your hard disk
햲 Make sure that the correct Microsoft Windows version is properly installed on your computer. For information on using Microsoft Windows please refer to the Windows
User's Guide.
햳 Start Microsoft Windows.
햴 Insert the installation CD-ROM in the CD-ROM drive.
The GX IEC Developer installation program starts automatically
(if not, execute the file SETUP.EXE on the installation CD-ROM).
햵 Follow the instructions that appear on the screen.
햶 Enter the user name, company name, and serial number of the software.
햷 Follow the instructions that appear on the screen.
햸 When the installation procedure is finished the program will create a new program group in the Start menu containing the GX IEC Developer program icon.
For further details on the necessary Microsoft Windows procedures please refer to your
Microsoft Windows documentation.
2.3
2.4
Starting GX IEC Developer
햲 In the Start menu click on the GX IEC Developer program icon. The icon is located in:
Start > Programs > MELSOFT Application > GX IEC Developer. This starts GX IEC
Developer and displays the start-up screen.
햳 Confirm with the
«
key.
Quitting GX IEC Developer
You can quit GX IEC Developer directly at any point in the program by pressing the key combination
¦
.
Or:
Double-click on the Quit command in the Project menu.
2.5
2 – 4
Bringing GX IEC Developer into the Foreground
When GX IEC Developer is active on the screen at the same time as one or more other applications you can bring GX IEC Developer into the foreground by double-clicking on its icon in the
Program Manager.
MITSUBISHI ELECTRIC
Installation
2.6
2.6.1
The MMP703.INI Program Initialisation File
The MMP703.INI Program Initialisation File
The MMP703.INI initialisation file contains important parameters required by the Windows application GX IEC Developer.
In previous versions of the GX IEC Developer, the MMPxxx.INI and MMPxxxProf.INI files were located in the Windows folder. Now these files are relocated to the folder indicated by the
COMMONFILESFOLDER environment variable (usually C:\Program Files\Common Files).
The installer will create a folder named “MELSEC\GX IEC Developer” and place the INI files there (
Format of the MMP703.INI File
MMP703.INI is arranged in several sections that all have the same basic format. The following list shows the standard and some sample settings. So your own INI file may look different!
Contents of the MMP703.INI File
(Standard and sample entries)
[PROJECTS]
Project0=C:\MMP_PROJ\SILO1
Project1=C:\MMP_PROJ\TEST3
Project2=C:\MMP_PROJ\EXAMPLE
Project3=C:\MMP_PROJ\SILO2
[CompatibleCpu]
A1=A1N
A2=A2N
FX0/FX0S=FX0 / FX0S
FX2=FX / FX2
FX2C/Vup=FXU / FX2U / FX2C
FX2N=FX2N / FX2NC
Q2A=Q2A(H)
Q2A / Q2AS=Q2A(H)
Q2A-S1=Q2A(H)-S1
Q2A-S1 / Q2AS-S1=Q2A(H)-S1
Explanation
PROJECT
List of the last four projects opened in GX IEC Developer
These projects are also displayed at the bottom of the Project menu.
DO NOT EDIT!
COMPATIBLE CPU
List of compatible CPU types
DO NOT EDIT!
Tab. 2-1:
Format of the MMP703.INI file (1)
GX IEC Developer Reference Manual 2 – 5
The MMP703.INI Program Initialisation File
Contents of the MMP703.INI File
(Standard and sample entries)
[OPTIONS]
StepZoom=1
FBZoom=1
MacroGraphics=5
AutomaticIOpin=TRUE
PinOverWrite=TRUE
IncremNewDecl=TRUE
CommentCopy=TRUE
ChkDeclareExternal=TRUE
ChkErrors=25
ChkWarnings=100
LRUProjects=4
ArrayElementsToShow=10
CanEditPou=FALSE
MinDiskSpace=20
DefaultStringLength=32
AutoExportSUL=FALSE
AutoImportSUL=FALSE
AutoIMEXSUL=TRUE
ErrorLogFile=C:\MELSEC\
GX IEC Developer 7.03\ERR.TXT
InitNetworkHeight=4
CreateTmpVarForPLS=TRUE
CreateTmpVarForPLF=TRUE
CreateTmpVarForALT=TRUE
AllowFBCallWithVarOut=FALSE
ErrorForOverlappingElementsExceptLines
=FALSE
AutomaticIOPinENO=FALSE
ErrorForOverlappingElementsExceptLines
=FALSE
LRUVarsel=3
AutoUpdate=TRUE
MonitorStringLen=16
OnlineChangeFreeSpace=500
ActiveSystemTimer=FALSE
AllTimerActive=FALSE
RD_Enabled=FALSE
RD_ExcludeLatched=FALSE
RD_Include_D_Devices=FALSE
RD_Include_M_Devices=FALSE
RD_Include_T_Devices=FALSE
RD_Include_C_Devices=FALSE
RD_Include_S_Devices=FALSE
RD_Include_ST_Devices=FALSE
MinimizeErrlistboxAfterShow=FALSE
MinimizeVarselAfterDeclare=FALSE
MinimizeFunselAfterDeclare=FALSE
DoNotShowFXOnlineChangeMessage
=FALSE
AdjustSFCActiveInfoTable=TRUE
OnlineToolbar=FALSE
ActionOnZoomIntoFbd=2
ActionOnZoomIntoPou=1
VarExportGlobalsOnly=FALSE
AutoUpdateAllUserLib=FALSE
AllowSpecialChar=FALSE
[Online]
OnlinePollrate=250
RunTimeSystem=Generic
Baudrate=19200
Bytesize=8
Parity=0
Stopbits=1
Port=COM1
Downloader=
Explanation
OPTIONS
in the EXTRAS menu
Detailed information see page 2-38
OPTIONS
in the EXTRAS menu
Detailed information see page 2-38
ONLINE
Online settings
Tab. 2-1:
Format of the MMP703.INI file (2)
Installation
2 – 6
MITSUBISHI ELECTRIC
Installation The MMP703.INI Program Initialisation File
Contents of the MMP703.INI File
(Standard and sample entries)
[View]
AutoLoadSaveWS=FALSE
ColorBackground=16777215
ColorForeground=12632256
ColorText=0
ColorSelection=8421504
ColorError=255
ColorBPEnabled=65535
ColorBPActive=65280
ColorMonitoring=65535
ColorTextLocked=8421504
ColorTextReadOnly=8421504
ColorShadeLT=16777215
ColorShadeRB=8421504
ColorGrid=0
ColorTextSelected=16777215
ColorBrowsedItem=16776960
ColorShadeMM=12632256
ColorSFCRasterElement=16777215
ColorCursorOvr=255
ColorCursorIns=16711680
ColorCursorLine=65280
ColorFillCursor=16711680
[LADDER]
HLineLength=4
Explanation
COLORS
The color setting (View - Colors) is also stored in the ini-file
(MMP703.ini) of GX IEC Developer 7.03 and no longer in the project. This means, that changes in the color setting have effect to all new or opened projects.
The entries in the column on the left represent the default values.
The entries in the ini-file are reset to the default values after activating the menu item View - System Defaults .
VLineLength=3
[RC_GROUP]
1=1,53,Clock, ,
2=2,73,Security Level, ,
3=3,150,Editor Info, ,
4=4,40,Online, ,
5=5,55,CpuType, ,
6=6,110,ConnStatus,
Not Connected,;Connection Status Box
7=7,110,ErrorStatus,
Not Connected,;Error Status Box
8=8,25,GuidedEditing, ,;Guided Editing Mode
9=9,200,Path,,
10=10,30,System Resources,,
11=11,50,Free Memory,,
12=12,110,Redundant Info,,
13=13,150,MXC status,,
[WORK_GROUP]
LEFT=20,2,8,
RIGHT=1,3,
[DEFAULT_GROUP]
LEFT=2,3,
RIGHT=1,
[LIBRARIES]
ManufacturerHelpPath=
C:\MELSEC\GX IEC Developer 7.03
ManufacturerLibPath=
C:\MELSEC\GX IEC Developer 7.03\
LIBSMMP
LADDER DIAGRAM
Horizontal length in Ladder diagram
Length in grid elements
Default setting: 4
Vertical height in Ladder diagram
Height in grid elements
Default setting: 3
STATUS BAR
Status bar configuration settings
DO NOT EDIT!
STATUS BAR
Field size of the status bar entries
DO NOT EDIT!
STATUS BAR
Field size of the status bar entries
DO NOT EDIT!
USER LIBRARIES
Directory for the library help files
Directory for the library files
Tab. 2-1:
Format of the MMP703.INI file (3)
GX IEC Developer Reference Manual 2 – 7
The MMP703.INI Program Initialisation File Installation
Contents of the MMP703.INI File
(Standard and sample entries)
Manufacturer0=Standard_Lib,
SLIB.lib,FUNCTION.HLP
Manufacturer1=Manufacturer_Lib,
MLIB.lib,FUNCTION.HLP
[PRINT]
PrintFrame=1
OemBitmap=C:\MELSEC\
GX IEC Developer 7.03\MEGLOGO.BMP
PrBitmap=C:\GX IEC Developer 7.03\
MMPLOGO.BMP
Explanation
Specification of the libraries
Max. 50 libraries are allowed.
Input order:
ManufacturerX=library name, library file, help file
(help file not necessary)
DO NOT EDIT!
PRINTOUT
=1: Printout options are enabled
=0: Printout options are disabled
Directory and file of bitmap
Bitmap is shown in the upper left corner in the page header
Directory and file of bitmap
Bitmap is shown in the upper right corner in the page header
Text in footer
3 text lines are shown in the page footer
Text1=Company XXX
Text2=Department XXX
Text3=Application XXX
PrintRaster=10
ScDoc=1
Size of printout
Default setting:10 depends on printer
ScDoc
ScDoc=1: Activates the interface to the documentation software
SCDoc.
[CrossReference]
GenerateSCT=TRUE
GenerateSCX=TRUE
GenerateSCXAfterBuild=FALSE
CROSS REFERENCE
Automatic link of the SCT files to the SCX file when creating the cross reference data base
=TRUE: Function enabled
=FALSE: Function not enabled
SCDOC
Section containing additional printer settings
[ScDoc]
ScPath=
NewBack=FALSE
NewBack1=FALSE
Changed=FALSE
Linkrev=FALSE
CallSc=FALSE
ScdPath=
Link=FALSE
LastPtr=
[PARAM]
COMPORT=0
PARAMETER
Selection of the COM port of Personal Computer
COMPORT=0 Selection of COM1
COMPORT=1 Selection of COM2
The selection of the COM port will not be saved together with the project. The COM port can be selected in the MMP703.INI.
[PATH]
CNF=C:\MELSEC\GX IEC Developer 7.03\
TYP_CNF
TYP=C:\MELSEC\GX IEC Developer 7.03\
TYP_CNF
EXE=C:\MELSEC\GX IEC Developer 7.03
LIB=C:\MELSEC\GX IEC Developer 7.03\
LIBSMMP
PPR=C:\MELSEC\GX IEC Developer 7.03\
PPR
MODEM=C:\MELSEC\GX IEC Developer 7.03\
MODEMSUP
16BITEXE=C:\MELSEC\GX IEC Developer 7.03\
MMPCNV\SC.EXE
PARAM=C:\MELSEC\GX IEC Developer 7.03\
DEFPARAM
GCDP=C:\MELSEC\GX IEC Developer 7.03\..\
DIRECTORIES
CNF Configuration files for all PLC types (special format)
TYP Configuration files for all PLC types (standard format)
EXE GX IEC Developer program files
PPR Project templates for all PLC types
DO NOT EDIT!
Tab. 2-1:
Format of the MMP703.INI file (4)
2 – 8
MITSUBISHI ELECTRIC
Installation The MMP703.INI Program Initialisation File
Contents of the MMP703.INI File
(Standard and sample entries)
[IEC_Export]
ExportFile=VARLIST.CSV
Separator=;
OverwriteExportFile=TRUE
AutoGenerateExportFile=FALSE
[WIZARD]
MELSEC=TRUE
[SFC]
GenerateSfcStartupCode=TRUE
[REG]
NAME: xxxxx
COMPANY: xxxxx
DISTRIBUTOR: xxxxx
SERIAL: xxxxx
[Ccodegen]
TabDump=TRUE
Explanation
IEC-EXPORT
Section containing settings for the IEC export functionality
WIZARD
Automatic POU and Task creation
MELSEC=TRUE
When you create a new project the Wizard is displayed on the screen with a prompt asking if you wish to create a POU and a task automatically.
MELSEC=FALSE
This setting disables the Wizard.
SEQUENCES
Automatic generation of startup code
LD M9039
OUT M9101
The special relay M9101 starts the execution of the SFC processing.
1) The section [SFC] or the entry GenerateSfcStartupCode does not exist or any of them is spelled incorrectly:
Ü The startup code will be generated automatically.
2) The section [SFC] and the entry GenerateSfcStartupCode exist and the value is set to either TRUE, YES or 1:
Ü The startup code will be generated automatically.
3) The section [SFC] and the entry GenerateSfcStartupCode exist and the value is set to any other value:
Ü The startup code will not be generated.
Usually the entry should be set to TRUE, to generate a proper
SFC processing.
GX IEC Developer REGISTRATION
Name/Company: information entered when you install GX IEC
Developer
Distributor/Serial: Distributor name and encoded serial number
DO NOT EDIT!
CODE-GENERATOR
When TabDump=TRUE the following files are generated in the project directory when GX IEC Developer is started with the
/debug option:
- PRECGEN.TAB
- POSTCMPR.TAB
- POSTCGEN.TAB
[devel] eds=TRUE
[DEVICE_SETTING]
USE_COLORS=1
SAFETY_INQUIRY=1
DEVICE EDITOR
Colors
Context menu - Options - Use Colors
=1: Use of different colors in display mode enabled
=0: Use of different colors in display mode disabled
Safety inquiry
Context menu - Options - Additional Safety Inquiry
=1: Additional safety inquiry prompt is displayed
=0: Additional safety inquiry prompt is not displayed
ENTRY DATA MONITOR
Configuration of Entry Data Monitor table
[EDM]
FIELD0=Name
FIELD1=Type
FIELD2=Address (IEC)
FIELD3=Value (dec)
FIELD4=Value (bin)
ObjListInclLibraries=1
Tab. 2-1:
Format of the MMP703.INI file (5)
GX IEC Developer Reference Manual 2 – 9
Installation The MMP703.INI Program Initialisation File
2.6.2
Editing MMP703.INI Entries
E
WARNING:
Most MMP703.INI parameters should not be edited by the user! Please observe the
DO NOT EDIT!
warnings in the table above.
How to make changes in the user-editable sections
햲 Create a backup copy of the file MMP703.INI in another directory or on a different drive.
Important: Allways create a backup copy, because if the changes you make do not work or result in unexpected problems when you run GX IEC Developer you can then restore the original file in the folder named “MELSEC\GX IEC Developer” in the common files section from the backup copy.
햳 Load MMP703.INI into a standard text editor such as the Windows Notepad utility.
Do not use an editor or word processor that inserts formatting codes in the text file, as the system would then no longer be able to read the file.
햴 Make the necessary editing changes.
햵 Save the edited file.
햶 Close the GX IEC Developer program and restart it.
Changes made to the MMP703.INI file do not take effect until you restart the
GX IEC Developer program.
2 – 10
MITSUBISHI ELECTRIC
Installation
2.7
2.7.1
Windows Vista Support
Windows Vista Support
File System Virtualization
When a limited user or a non-elevated administrator launches an application that is not aware of Windows Vista’s User Account Control system, a Vista feature called “virtualization” is activated. If such an application attempts to write in a folder where it has no write rights (e.g. the
Windows and Program Files folders), the created file is automatically redirected to a folder in the user’s profile (i.e. usually to the folder C:\Users\[username]\AppData\Local\VirtualStore).
In the Windows Common Dialogs, these redirected files are visible as if they were in the original folder. In Windows Explorer, they can be revealed with the button Compatibility Files.
Fig. 2-1:
Windows Vista Explorer
Since this Vista feature interferes with the project creation process of GX IEC Developer, this feature has been disabled in GX IEC Developer Version 7.03. Attempting to create or save a project or file in a folder without having write access rights to that folder will fail, and an error message will be displayed. The affected functionalities and the shown error messages are described in the following section.
GX IEC Developer Reference Manual 2 – 11
Windows Vista Support
2.7.2
Installation
File Write Error Messages
Creating a folder
The following error messages will be displayed in the various functionaliaties when you attempt to create a folder without having write permission to its parent folder:
Fig. 2-2:
Error message when creation of a folder fails
The error message in Fig. 2-2 is shown when:
쎲 Creating a project (ProjectàNew…)
쎲 Saving a project to a new location (ProjectàSave As…)
쎲 Copying a project (ProjectàOtheràCopy…)
쎲 Upload from PLC to a new project (ProjectàTransferàUpload from PLC…)
쎲 Restoring a backup project (ExtrasàProject Restore…)
Fig. 2-3:
Error message when renaming (moving) a folder
2 – 12
The error message in Fig. 2-3 is shown when:
쎲 Renaming (moving) a project (ProjectàOtheràRename…).
MITSUBISHI ELECTRIC
Installation Windows Vista Support
Creating a file
When a GX IEC Developer functionality needs to write a file, the common Windows file selection dialog is shown. Under Windows Vista the following message is displayed by the operating system in the file selection dialog when you attempt to save a file in a folder where you have no write permission. If you choose Yes, the current folder is changed to the user’s profile folder. If you choose No, the Common Dialog remains open.
Fig. 2-4:
Error message when writing a file in a folder without write permission
However, this message will not be displayed if you select an existing file in a folder where you do not have write permission. Therefore, the following error messages – displayed by GX IEC
Developer when a file writing operation fails – will be shown, which include the write permission information.
Fig. 2-5:
Error message when file writing operations fail in ASCII export
The error message in Fig. 2-5 is shown when:
쎲 ASCII export of project (ProjectàOtheràExport…)
쎲 ASCII export of object (ObjectàExport…)
GX IEC Developer Reference Manual 2 – 13
Windows Vista Support Installation
Fig. 2-6:
Error message when file writing operations fail in Excel export
2 – 14
The error message in Fig. 2-6 is shown when:
쎲 Excel export in EDM
쎲 Excel export in the EDM Setup dialog
쎲 Excel export in Device Edit
쎲 Excel export in Forced Input/Output Registration/Cancellation
쎲 Excel Export in Declaration Editors
쎲 Excel Export in the DUV Address dialog
Fig. 2-7:
Error message when file writing operations fail in export to
Eprom
The error message in Fig. 2-7 is shown when:
쎲 Exporting to Eprom (for A PLCs) (ProjectàOtheràExport to Eprom)
MITSUBISHI ELECTRIC
Installation
The error message in Fig. 2-8 is shown when:
쎲 Save Build logfile (ProjectàBuild, ProjectàRebuild All)
Fig. 2-9:
Error message when file writing operations fail in reading from a
PLC
The error message in Fig. 2-9 is shown when:
쎲 Reading from PLC in File Info (OnlineàFile Info)
Windows Vista Support
Fig. 2-8:
Error message when file writing operations fail in building a logfile
GX IEC Developer Reference Manual 2 – 15
Windows Vista Support Installation
Fig. 2-10:
Error message when file writing operations fail in backing up a project
The error message in Fig. 2-10 is shown when:
쎲 Backing up a project (ExtrasàProject Backup…)
Fig. 2-11:
Error message when file writing operations fail in exporting variables
The error message in Fig. 2-11 is shown when:
쎲 Exporting variables to CSV file (ExtrasàExport Variables)
2 – 16
MITSUBISHI ELECTRIC
Installation Windows Vista Support
Fig. 2-12:
Error message when file writing operations fail in exporting alarm info
The error message in Fig. 2-12 is shown when:
쎲 Exporting SV Alarm Info (ExtrasàSVàExport Alarm Info)
Fig. 2-13:
Error message when file writing operations fail in reorganizing a database
The error message in Fig. 2-13 is shown when:
쎲 Reorganizing a database (ToolsàReorganize Database)
GX IEC Developer Reference Manual 2 – 17
Windows Vista Support Installation
Project Open Error Message
GID projects cannot be opened if any of the project files are write protected, or if you have no write access to the project. The following extended error message will be shown.
Fig. 2-14:
Error message when opening a project fails
The error message in Fig. 2-14 is shown when:
쎲 Opening a project (ProjectàOpen…)
쎲 Verifying a project (ProjectàOtheràVerify…)
2 – 18
MITSUBISHI ELECTRIC
Installation
2.7.3
Windows Vista Support
INI File Location in Windows Vista
In previous versions of the GX IEC Developer, the MMPxxx.INI and MMPxxxProf.INI files were located in the Windows folder. In Windows Vista limited users and non-elevated administrators have no write access rights to this folder; therefore you would not be able to save any options stored in these files.
Because of this, now these files are relocated to the folder indicated by the
COMMONPROGRAMFILES environment variable (usually C:\Program Files\Common Files).
The installer will create a folder named “MELSEC\GX IEC Developer” and place the INI files there. Since all users have write access to this folder, you will be able to save the global options here.
Fig. 2-15:
Windows Vista Explorer
GX IEC Developer Reference Manual 2 – 19
General Options
2.8
2.8.1
General Options
The options are configured in the Extras - Options menu.
Cross Reference
Installation
Fig. 2-16:
General Options -
Cross Reference
Cross Reference Options
Used to define the options for generation of the cross reference database.
Generate *.SCT files while checking a project: Activates generation of the SCT files during project checks.
Automatically link the *.SCT files to the *.SCX file after ‘Rebuild All': Activates automatic linking of the SCT files to the SCX file after compiling a project.
Automatically link the *.SCT files to the *.SCX file after ‘Build': Activates automatic linking of the SCT files to the SCX file after building a project.
2 – 20
MITSUBISHI ELECTRIC
Installation
2.8.2
CSV-Export
General Options
Fig. 2-17:
General Options -
CSV-Export
NOTE
All variables defined in the GVL and the POU header of a project can be exported as ASCII file in Comma Separated Value format (*.csv).
Export File: Enter the path and name of the file to be exported
Separator: Select either the “Comma” or the “Semicolon” as separator character between values.
Export file: Select whether to either “Overwrite existing export file” or to “Backup existing file in
.CSX file”.
Generate export file after every successful build process: Activate this option, if desired.
Export global variables only: If this option is checked, only global variables are exported by the Extras
à Export Variables functionality. Local variables and type info are omitted.
Please also note the following section.
GX IEC Developer Reference Manual 2 – 21
General Options Installation
Project name substitution in CSV-Export file name
The Export filename specified in Extras
Options
CSV-Export will be checked if it contains the following string: “$(PrjName)”. If this string is found, it will be replaced with the short name of the current project. If a relative path, or a file name without a path is specified, it will be extended to a full path using the current project path.
Fig. 2-18:
General Options -
CSV-Export with project name substitution
Full project path
(as an example)
D:\Projects\MyProject
D:\Projects\MyProject
D:\Projects\MyProject
D:\Projects\MyProject
D:\Projects\MyProject
D:\Projects\MyProject
Export file setting
VarList.csv
Export\VarList.csv
D:\Exports\VarList.csv
$(PrjName).csv
Export\$(PrjName)
D:\Exports\$(PrjName).csv
Tab. 2-5:
Examples of the generated file names
Full path of generated export file
(as an example)
D:\Projects\MyProject\VarList.csv
D:\Projects\MyProject\Export\VarList.csv
D:\Exports\VarList.csv
D:\Projects\MyProject\MyProject.csv
D:\Projects\MyProject\Export\MyProject.csv
D:\Exports\MyProject.csv
2 – 22
MITSUBISHI ELECTRIC
Installation
2.8.3
Editing
General Options
Fig. 2-19:
General Options -
Editing
Declaration Editor
Auto update: Updates global and local variables automatically after changing a variable declaration. The following changes of a variable declaration are updated: Class, Identifier,
Address, Type, Initial. All changes made in the GVL will also be executed in the POUs.
When you change a POU header, its body will also be changed automatically. The variables are updated after the declaration editor changes have been saved.
Auto update all user libraries: Global variables defined in the project GVL can also be referenced from POUs in a user library, but those variables are not updated by the
Auto update. Similarly when a global variable defined in a user library GVL is changed, its references are not updated in other open user libraries, only in the user library having the global variable, and in the project POUs. Checking this option automatic updates all open user libraries. If there are no references in the user libraries to global variables of the project or another user library, you should turn this option off
(uncheck) to enhance the performance of auto update.
Incremental New Declarations: When this option is enabled the contents of the previous lines are copied automatically when new lines are inserted in the declaration tables. The designators and addresses are automatically incremented by 1. If you also want the system to copy the contents of the type and comment fields you must also enable the
Copy Comment and Type Fields
check box.
Copy Comment and Type Fields: See Incremental New Declarations.
GX IEC Developer Reference Manual 2 – 23
General Options Installation
FBD/LD
Declare New Identifiers: When you overwrite a dummy variable in a graphical editor with a variable identifier name that has not yet been declared the Variable Selection
(Mode NewVar) dialogue box will be displayed automatically so that you can enter the declaration for the new variable.
Pin Overwrite: When you create a connection to an empty variable connection in a graphical editor the empty variable will be overwritten.
Automatic Input/Output Variables: The system will automatically create the input and output variables when you insert a function block in a graphical editor.
Automatic ENO Variables: The system will automatically create the ENO output variable when you insert a function block in a graphical editor. If the ENO output variable is not needed this option has to be disabled.
2 – 24
MITSUBISHI ELECTRIC
Installation
2.8.4
General
General Options
Fig. 2-20:
General Options -
General
Error Log File
Path and filename for the error log file.
Stop Check By
Errors: Stop the check operation when the number of errors found exceeds the maximum limit specified here.
Range: 1 - 9,999
Warnings: Stop the check operation when the number of warnings exceeds the maximum limit specified here.
Range: 1 - 9,999
Default string length (characters): You can set the default length of the STRING data type to any value up to a maximum of 50 characters.
Array elements to show: The Entry Data Monitor can display the individual elements of an array, but this can be impossible if the array is too large. This option enables you to set the number of array elements to display to a maximum of 50 (
You can also change this value in the prompt dialogue that is displayed when you open an array in the Entry Data Monitor.
Most recently used files (number): The last projects opened are always displayed at the bottom of the Project menu. You can set the number of projects to be displayed to a maximum of 9.
Minimum disk space (Mbytes): GX IEC Developer displays a warning message when the amount of free space available on the current drive falls below the value specified here.
Allow special characters for identifier names
If checked, special characters can be used for identifier names. The following special characters are supported as valid characters:
쎲 ä, Ä, ö, Ö, ü, Ü, ß, _, å, Å
GX IEC Developer Reference Manual 2 – 25
General Options Installation
The usage of these characters is valid for the following identifier and all functionalities where these identifiers are used (e.g. Variable selection dialogue):
쎲 Library names
쎲 Task names
쎲 DUT names and DUT component names
쎲 Global and local variable names
쎲 POU names (PRG, FUN, FB)
쎲 Network label names
쎲 SFC Transition names
쎲 SFC Action names
쎲 SFC Step names
쎲 SFC Jump label names
The character ‘_’ (underscore) was already allowed in older versions of GX IEC Developer.
Due to the restrictions by the IEC naming convention it was not allowed to use a double underscore character at the beginning of an identifier (e.g. “__TestVar”). Additionally there was a restriction for the usage of the underscore character as the last character of an identifier (e.g.
“TestVar_”). These restrictions can now be disabled by the user.
These identifiers can be used in every program editor:
쎲 LD
쎲 FBD
쎲 IL
쎲 MELSEC-IL
쎲 SFC
쎲 ST
2 – 26
MITSUBISHI ELECTRIC
Installation
2.8.5
Graphic
General Options
Fig. 2-21:
General Options -
Graphic
Predefined network height when inserting: The initial height of a network.
Range: 4 - 100 grid points
Default: 4
Horizontal grid length of line segment: Horizontal length of line segments in the ladder diagram editor, in grid points.
Range: 1 - 100 grid points
Default: 4
Vertical grid height of line segment: Vertical length of line segments in the ladder diagram editor, in grid points.
Range: 1 - 100 grid points
Default: 3
Number of graphic macros: Number of additional graphic macros available.
Graphic macros 1 through 5 are always available.
Range: 5 - 25
Default: 5
GX IEC Developer Reference Manual 2 – 27
General Options
2.8.6
Import/Export
Installation
Fig. 2-22:
General Options -
Import/Export
Import/Export options
Specifies how the user libraries are handled when a project is imported or exported.
Automatic import/export of user libraries:
Enables the automatic import or export of the user libraries.
Import all user libraries of the import file without any user confirmation:
Imports all user libraries without requesting any confirmation.
Export all user libraries of the current project without any user confirmation:
Exports all user libraries without requesting any confirmation.
2 – 28
MITSUBISHI ELECTRIC
Installation
2.8.7
LD-Guided Mode
General Options
Fig. 2-23:
General Options -
LD-Guided Mode
Wrapping of Ladder circuit
Do not wrap: Do not wrap the ladder circuit. This setting is applicable for the circuit that is going to be edited after making this setting and not for the pre-created circuits.
Wrap after: Wrap if the ladder circuit exceeds the n th component position. This setting is applicable for the circuit that is going to be edited after making this setting and not for the pre-created circuits.
Components: The number of components to wrap after.
Range: 2 - 100
Default: 8
Auto comment Block width / Components: Set the auto comment block with a width of n components in the network.
Range: 1 - 100
Default: 8
Set Guided Mode as default editing mode: The LD editor should be opened in Guided Mode by default.
Allow Hotkey Repeater: The hotkey repeater window will be displayed whenever the Horizontal or Vertical Line hotkey is pressed or accessed through the menu.
GX IEC Developer Reference Manual 2 – 29
General Options
2.8.8
LD-Variable Name
Installation
Fig. 2-24:
General Options -
LD-Variable Name
2 – 30
Settings for input/output variable names
Limit variable name display for input/output variables: When this option is checked, the display of variable names for input/output variables is limited to the specified number of characters.
default: unchecked
Visible characters per variable: Maximum number of characters for displaying input/output variable names
Range: 2–255 characters default: 12
Settings for contact/coil variable names
No multiline variable naming: When this option is checked, variable names are displayed in one line.
Display variable name in: When this option is checked, a variable name will be wrapped or folded in n lines in the network display.
Range: 1–4 lines
Default: 1
Visible characters per line: Maximum number of characters for displaying multiple line variable names.
Range: 2–255 characters default: 8
Allow Multiline for instance names: If checked, variable names for function blocks will be displayed in multiple lines. The number of characters per line depends on the function block width.
Do not allow “?” as a variable name: Do not allow the user to give the “?” mark as variable name in Guided Mode. When this option is checked, you must specify a proper variable name whenever you place a new program component in the network.
MITSUBISHI ELECTRIC
Installation
2.8.9
Monitor Indication
General Options
Fig. 2-25:
General Options -
Monitor Indication
If the monitor mode is active, the corresponding icon in the toolbar changes its colour from black to red.
Indicate Monitoring by Title bar of
GX IEC Developer main window: If the monitor mode is active and objects are monitored in one window at least (e.g. body of a POU or Entry Data Monitor), the text
"Monitoring" in the title bar of GX IEC Developer is blinking according to the defined blink rate.
Window to be monitored: If the monitoring is started for a window (e.g. body of a POU or Entry Data Monitor), the text "Monitoring" in the title bar of this window is blinking according to the defined blink rate.
Blink Rate: The blink rate can be adjusted depending on the poll rate.
Range: 1 - 10
Default: 1
GX IEC Developer Reference Manual 2 – 31
General Options
2.8.10
Monitor Mode
Installation
Fig. 2-26:
General Options -
Monitor Mode
2 – 32
Displayed String Length: Displaying long strings significantly reduces performance in monitoring mode. It is thus advisable to limit the number of characters to be displayed.
Range: 2 - 50
Default: 16
Poll rate: Interval at which the monitor polls the CPU, expressed in ms.
Range: 1 - 5,000 ms
Default: 250 ms
Word type variables
Decimal: Displays monitor values of word type variables in decimal format.
Hexadecimal: Displays monitor values of word type variables in hexadecimal format
(default setting).
This feature is also available in editors of the type IL, LD, FBD, and MIL via a context menu when the monitor mode is active.
Fig. 2-27:
Indication of word type variables
SFC
If the SFC body is observed in the monitor mode, you have to scroll through the window. This can be done manually or by means of the autoscroll function.
The autoscroll function tracks the active steps of the SFC and scrolls the window automatically. The horizontal and vertical position of the active step in the window can be defined.
If the SFC includes more than one active step, the upper left active step is used for autoscrolling.
MITSUBISHI ELECTRIC
Installation
2.8.11
General Options
Even an active macro step is opened and the active step inside the macro step is scrolled into view. If all steps get inactive in the SFC macro step, it is closed and the former shown level is shown again.
If you have zoomed into a macro step before you started the monitoring or during monitoring, this level is not left for the next higher level even when no step is active.
Enable autoscroll: These settings define the position where the active step will be scrolled to (0 % / 0 % is the upper left corner).
Range: 0 - 100 %
Default: 10 %
ST Editor
Fig. 2-28:
General Options -
ST Editor
Auto indentation: Auto indentation
Identifier proposal: Identifier proposal
Line number status: Line number status
Tabulator length: Set Tabulator length
Range: 1 - 64
Default: 4
GX IEC Developer Reference Manual 2 – 33
General Options
2.8.12
Tooltips
Installation
Fig. 2-29:
General Options -
Tooltips
Enable Tooltips: This checkbox when checked enables the Tooltips without resetting the display options.
Show tooltip for
Monitored value: If checked, tooltips are shown for monitored values.
Class: If checked, tooltips are shown for classes.
Mitsubishi address: If checked, tooltips are shown for Mitsubishi addresses.
IEC address: If checked, tooltips are shown for IEC addresses.
Type: If checked, tooltips are shown for types.
Initial value: If checked, tooltips are shown for initial values.
Comment: If checked, tooltips are shown for comments.
Remark: If checked, tooltips are shown for remarks.
Display tooltip in
Single line: Tooltips are shown in one single line.
Multiline: Tooltips are shown in multiple lines, if necessary.
2 – 34
MITSUBISHI ELECTRIC
Installation
2.8.13
Transition Condition
General Options
Fig. 2-30:
General Options -
Transition Condition
When opening the transition's rectangle (e.g. by double click or by Zoom Into)
Transition Condition: is selected.
The TC editor will appear.
Standard Body: is selected.
The standard body editor will appear for new transitions.
GX IEC Developer Reference Manual 2 – 35
General Options
2.8.14
Variable Selection
Installation
Fig. 2-31:
General Options -
Variable Selection
Setting for Variable Selection: Determines which library is pre-initialised when the Variable
Selection dialogue is shown.
Range: Header, Global Variable, Last Selected Entry
Default: Last Selected Entry
Setting if variable exists in GVL: Determines which library is pre-initialised when the
Variable Selection dialogue is shown from the LD/FBD when you type a variable name that is not defined in the header but exists in the GVL.
Range: Ask, Use Global, Define Local
Default: Use Global
Setting if variable doesn’t exists: Determines which library is pre-initialised when the
Variable Selection dialogue is shown from the LD/FBD when you type a variable name that is not defined either in the header nor the GVL.
Range: Ask, Define Global, Define Local
Default: Ask
2 – 36
MITSUBISHI ELECTRIC
Installation
2.8.15
Zoom Header/Body
General Options
Fig. 2-32:
General Options -
Zoom Header/Body
Navigator Zoom
Expand: Double-clicking on entries in the POU Pool displays/hides lower levels in the hierarchy (default).
Open Header: Double-clicking on entries in the POU Pool opens the corresponding header.
Open Body: Double-clicking on entries in the POU Pool opens the corresponding body.
FBD/LD Zoom
Open Header: Double-clicking on a function block in a graphical editor opens the corresponding header (default).
Open Body: Double-clicking on a function block in a graphical editor opens the corresponding body.
Step Zoom Into
Step Action Association: Double-clicking on a step opens the Action Association dialogue box (association of an action to a step).
First Action If Any: If actions are already associated with the step double-clicking on the step displays the PLC program of the first action in the list.
Comment: Double-clicking on a step displays the Comment dialogue box
(for entering comment texts).
GX IEC Developer Reference Manual 2 – 37
Project specific options
2.9
Installation
Project specific options
The options are configured in the Extras - Options menu.
The MM+ versions 2.40 and higher provide the possibility to define project specific settings.
The project specific settings will be saved together with the project in the database.
Availability
Due to the fact that the project specific options belong to a specific project and are no general settings, these options in the Options dialogue are available only if a project has been loaded.
To indicate that these settings refer only to the project currently loaded, the title of the Options dialogue is Project Specific Options.
Database
Opening old projects
When opening old projects, i.e. projects created by lower MM+ versions, missing settings will be filled up with the settings included in the .INI file. If the entries in the .INI file are not available, hard coded settings will be inserted instead.
Creating new projects
When creating new projects the individual default values included in the .INI file are inserted. If the entries do not exist in the .INI file, the hard coded default settings are inserted instead.
This behaviour is exactly the same as to open the Options dialogue and pressing the button
Load Defaults of both sections.
Compatibility
Due to the necessary changes in the database a project created by means of MM+ 2.40 or higher cannot be opened by lower MM+ versions.
Files with the extensions *.PRO and *.PCD generated by MELSEC MEDOC
plus
2.50 or lower can not be opened by the current version of GX IEC Developer. In this case we recommend the import/export functions or an external conversion tool (available on request).
2 – 38
MITSUBISHI ELECTRIC
Installation
2.9.1
Code Generation
Project specific options
Fig. 2-33:
Project Options -
Code Generation for QnA and System Q series
Fig. 2-34:
Project Options -
Code Generation for A and FX series
The section Code Generation is available for all CPU types.
Generate code for Manual SFC Control
This item is available for Q and QnA CPUs only, except Q00, Q00J, Q01, Q25SS, and
QnU(D)(E)(H).
If this option is enabled, a special sequence code is generated which includes one SET and one RST instruction for the steps S0–Sn, where n is the maximum step number of all SFC
POUs. The code also includes a BRSET instruction at the beginning which sets the current block according to a system word register.
This code helps to influence the step flags of every SFC block by setting the values for the D and M devices. By the SFC editor only on SFC block can be handled at one time. Using LDP allows to set a step in a running SFC without risking to activate the same step again several times.
GX IEC Developer Reference Manual 2 – 39
Project specific options Installation
The following checks are performed during the manual SFC control operation:
쎲 The consistency is checked between PLC and project.
쎲 The PLC must operate in RUN mode.
Generated sample code:
LDP
AND
SET
LDP
AND
RST
:
LD> K-1 D2048
BRSET D2048
LDP M4098
AND M4100
SET
LDP
AND
RST
:
S0
M4099
M4101
S0
M4098
M4120
S10
M4099
M4121
S10
Time Scheduler
This item is available for Q and QnA CPUs only. Timers in the A series CPU are not executed in the same way as those in the Q/QnA series CPU. If a jump is made over a program part containing a timer, the timer behaviour differs as follows:
MESEC A series
The timer will still be running and the timer value will be incremented.
MELSEC QnA series
The timer will be stopped and the timer value and the status will be kept.
Tab. 2-6:
Timer behaviour of A and QnA series
If an A series project has been converted to a Q/QnA series project, the described timer behaviour may result in a different execution of the complete project, especially in the following cases:
쎲 use of MELSEC function blocks
(e.g. TIMER_10_FB, TIMER_CONT_FB, TIMER_HIGH_FB)
쎲 use of IEC function blocks (e.g. TOF, TON_HIGH)
쎲 internal use of timers (e.g. timers controlling tasks)
쎲 direct use of timers and retentive timers (via index qualification as well)
In order to avoid the different timer behaviour the timer scheduler function can be used. The timer scheduler generates a special code which ensures the same timer behaviour in the
Q/QnA series CPU as in the A series CPU.
2 – 40
MITSUBISHI ELECTRIC
Installation Project specific options
If the timer scheduler is activated, the new code generation causes the following disadvantages:
쎲 The project needs more system variables.
쎲 The scan timer will be longer.
쎲 The code size will be bigger.
The timer scheduler can be activated/deactivated in this dialogue.
Generate code as in GX IEC Developer 5.02
The code generation option is available for all CPU types. For A and FX series all entries are disabled except the compatibility flag. The button Load Defaults and Save As Defaults will work only on the compatibility and different code warning flag of the Code Generation options for A and FX series.
If the compatibility flag is set the same sequence code is generated as in GX IEC Developer
5.02. For old 32bit projects the compatibility flag is automatically set. For old 16bit projects and for new projects the value of the compatibility flag depends on the default values, which were saved by the user. If no default value is found in the INI file for the compatibility flag, FALSE is taken.
If the different code warning flag is set, a warning is shown for every location where a different code is produced in GX IEC Developer 7.03 compared to GX IEC Developer 5.02. The messages of the warnings are different depending on the flag Generate code as in GX IEC
Developer 5.02.
For old 32bit projects the different code warning flag is automatically set. For old 16bit projects and for new projects the value of the different code warning flag depends on the default values, which were saved by the user. If no default value is found in the INI file for the different code warning flag, TRUE is taken.
In GX IEC Developer 5.02 a boolean destination of some standard functions and of user functions with EN/ ENO is changed even when the EN is FALSE. When the compatibility flag is not set the boolean destinations keep their values and are not changed.
According to the value of the compatibility flag a different code is produced in GX IEC Developer 7.03 for the standard functions with boolean destinations:
쎲 INT_TO_BOOL_E, WORD_TO_BOOL_E
쎲 DINT_TO_BOOL_E, DWORD_TO_BOOL_E, TIME_TO_BOOL_E
쎲 LIMIT_E
쎲 NOT_E
쎲 EQ_E, NE_E, GT_E, GE_E, LT_E, LE_E
쎲 CPY_BIT_OF_INT, CPY_BIT_OF_INT_E
쎲 AND_E, OR_E, XOR_E
쎲 MAX_E, MIN_E
To get the same code produced in GX IEC Developer 7.03 as in GX IEC Developer 5.02
without setting the compatibility flag, the above standard functions could be replaced with the functions without EN/ENO where the boolean result is connected to an AND block with the former EN as other input. The former destination must then be used as output of the AND.
GX IEC Developer Reference Manual 2 – 41
Project specific options Installation
Show warnings for different coding compared with GX IEC Developer 5.02
When enabled a warning is shown for every location where different code is produced in
GX IEC Developer 7.03 compared to GX IEC Developer 5.02.
Use SET/RST for Boolean Outputs
If a SET/RST flag is not set, the generated code uses the OUT instruction to write to the bit output for the according EN/ENO functions in LD/FBD.
Allow SFC reset variable as transition
An SFC POU of an FX project can have a “reset variable”, a Boolean variable which – when activated – resets all steps and sets the initial step. Using this variable as transition has no use, because when the transition’s state gets switched on, the control will get back to the initial step, not to the step or steps following the path of the transition.
(Also see: EMERGENCY OFF for FX Series, page 6-18.)
You are able to choose if such a situation should lead to an error or a warning.
The following warning will be produced by the compiler if an SFC reset variable is used as transition and it is allowed in the Options:
C9175 SFC reset variable used as transition.
The following error will be produced by the compiler if an SFC reset variable is used as transition and it is not allowed in the Options:
C9175 SFC reset variable used as transition. This error can be converted to a warning in the Options.
Activate all initial steps in the first scan
This option is available for the FX series only. It allows the control of the activation of the initial step by the user.
The default status is enabled. The compiler will produce a sequence code to activate all initial steps in the first scan. When this option is not checked the sequence code is not produced.
If you want to keep the status of the steps of the SFC POUs for the FX series, you must deactivate the option, latch all step flags of the system variable address range and control the activation of the SFC POUs by their according SFC Reset variables.
2 – 42
MITSUBISHI ELECTRIC
Installation
2.9.2
Compiler
Project specific options
Fig. 2-35:
Project Options -
Compiler
Create temporary variables for instruction PLS_M / PLF_M / ALT_M
System variables are required for internal processing when the output variables of the instructions PLS_M, PLF_M and ALT_M are used to activate additional instructions. If you use many instructions of this kind the maximum limit for number of system variables (system labels) that you can use can be reached very quickly.
If this happens you should disable the option Create temporary variables for instruction
PLS_M / PLF_M / ALT_M. Your PLC program must then be modified accordingly.
Default: Enabled
Fig. 2-36:
Output writes directly to the device
(no system variable required)
Output activates the MOV instruction (uses 1 system variable)
GX IEC Developer Reference Manual 2 – 43
Project specific options Installation
Example
Function block calls - Allow VAR_OUTPUT in call of FB (IL and ST)
If checked it is allowed to use a VAR-OUTPUT assignment directly with the call of a FB instance. E.g. CAL FBInst (FBVarOut:=Variable).
Function block calls - Allow unassigned inputs for Macro-FB calls
This option can be used to decide, if an unassigned input in a macro will result in a compiler warning or a compiler error.
In the following examples the same Macro-FB instance is called with the same operands. In all three cases the assignment for the input parameter "ValueIn" is missing.
NOTES
Fig. 2-37:
Examples for missing assignments
Although this is not illegal, and can be used on purpose, it is a potential source of problems.
쑶
By this compiler option the user can select if missing input assignments in Macro-FB calls should result in a compiler error or a compiler warning.
If this option is checked, unassigned inputs result in compiler warnings. And if unchecked, unassigned inputs result in compiler errors.
If the option is changed from checked to unchecked, the error will not be found in already compiled POUs when Build is called, only when Rebuild All is called.
The reason is that already compiled, errorless POUs are not checked again during incremental build, only if some change in the project affects them or Rebuild All is called.
To inform the user about this behavior, a message is displayed when the option is changed from checked to unchecked, which has to be confirmed by pressing the OK button.
For further details concerning macros please see sections 6.7.7 and 6.7.8.
2 – 44
MITSUBISHI ELECTRIC
Installation Project specific options
Variables - Allow local variable with the same name as a global variable
If checked, global variable hiding will not be considered to be an error. This option allows to choose if global variable hiding should be considered to be a programming error or not. By default, if a local variable of a POU has the same name as a global variable, an error will be shown when the POU is checked. If you turn this option on, global variable hiding will be allowed and the POU will be compiled.
Variables - Allow lower case Mitsubishi device/constant names as variable names
This option is used to give the user a hint, that a Mitsubishi Device or Constant could be hidden by a variable declaration with lower case letters.
쎲 If the option is checked, a warning is shown when a Mitsubishi device/constant name is used in a lower case format as variable name.
쎲 If the option is unchecked, an error is shown when a Mitsubishi device/constant name is used in a lower case format as variable name.
Disable Compiler Warnings
The display of compiler warnings in the error box during a Check, Build, or Rebuild all execution can be disabled. Default setting: Warnings enabled.
To disable a compiler warning, take the following steps:
햲 Enter the compiler warning code in the edit field.
햳 Press the Add... button.
The compiler warning is disabled and listed in the list box.
To enable a compiler warning, take the following steps:
햲 Select a compiler warning code from the list box.
햳 Press the Delete... button.
The compiler warning is enabled and removed from the list box.
User defaults
The user defaults are handled by three functional buttons:
쎲 Reset Defaults, resets the settings to the manufacturer default settings
(saved user defaults will remain untouched)
쎲 Load Defaults, loads user defaults
쎲 Save As Defaults, saves the current settings as your own user defaults
These ease the setting by giving you the opportunity to define and reload your own default settings (the so called “user defaults”). Initially the user defaults are the same as the manufacturer defaults, until you save different, user defined settings as defaults by using the button
Save As Defaults.
On creating a new project, the options will then be set to the user defaults. Similarly, when opening an existing project last saved with GX IEC Developer version 7.03 or earlier, the options will be set to your own user defaults. Afterwards, when the project is saved in the new version, the compiler options become part of the project and can be set individually.
GX IEC Developer Reference Manual 2 – 45
Project specific options
2.9.3
Online Change
Installation
Fig. 2-38:
Project Options -
Online Change for QnA and System Q series
Fig. 2-39:
Project Options -
Online Change for FX series
2 – 46
The section Online Change is available for all CPU types except the A series.
Allow online change for inconsistent projects
See section 8.7.1 for further details.
Additional program size
This item is available for Q and QnA CPUs only. Due to the file structure of the MELSEC Q and
QnA CPUs it is necessary to define an additional program range (in units of steps) for online changes (
After the Additional Program Size has been changed, the value will be checked when leaving the dialogue. This check can be done via the OK button or changing the section by clicking on another entry in the List Options. In case of an error an error message will appear.
MITSUBISHI ELECTRIC
Installation Project specific options
Automatic transfer from program cache to program memory
This item is available for QnU CPUs only. When checked, the contents of the program cache will be automatically transferred to the program memory after online program change operation. Otherwise the user will be asked after each online program change operation whether the transfer should be made.
For further information refer to section 8.6.6.
GX IEC Developer Reference Manual 2 – 47
Project specific options
2.9.4
Redundancy
Fig. 2-40:
Project Options -
Redundancy for QnPRH PLCs
Installation
The section Redundancy is available only for QnPRH CPUs.
Allow device writing on the Standby system: If checked, device writing on the standby system is enabled, and the following confirmation message will be displayed when attempting to write on the standby system.
Fig. 2-41:
Confirmation message
2 – 48
Show redundancy information in title bar of online dialogs: If checked, information about the status of the redundant system will be displayed in the window title for specific functionalities on QnPRH PLCs in the following format:
Original window title - Actual operating mode – Status of connected system
Fig. 2-42:
Title bar with redundancy information
The following functionalities are included:
쎲 Device Edit
쎲 Buffer Memory Batch Monitor
쎲 File Info
쎲 Format Drive
쎲 Monitoring Indicator
쎲 User Errors
쎲 Hardware Diagnostics
쎲 Scan Time
쎲 Forced I/O Registration/Cancellation
MITSUBISHI ELECTRIC
Installation Project specific options
Synchronize file selection if both systems are enabled: This option is relevant if operations on both systems are enabled in the menu Online - File Info (
The synchronization of selected files concerns the selected files in the file lists of the two systems.
When this option is checked, the selections in the two file lists will be kept synchronized. Any changes in selections in one list will be automatically reflected in the other list (if the selected/unselected file also exists on the other PLC).
GX IEC Developer Reference Manual 2 – 49
Project specific options
2.9.5
Reset Devices
Installation
Fig. 2-43:
Project Options -
Reset Devices
If the option Enable reset system devices is not selected, all other options are disabled to indicate that the reset devices are not active.
Reset Defaults
When pressing the button Reset Defaults the settings of this section are reset to their default values, i.e. the hard coded settings are loaded. This is especially helpful to restore the original settings.
Load Defaults
When pressing the button Load Defaults the default settings saved in the .INI file are loaded.
If the .INI file does not include any entries, the hard coded settings are loaded.
Save As Defaults
When pressing the button Save As Defaults the current settings are saved as default settings to the .INI file. If the .INI file does not include any saved default settings yet, they will be created by this operation.
2 – 50
MITSUBISHI ELECTRIC
Installation
2.9.6
System Variables
Project specific options
Fig. 2-44:
Project Options -
System Variables
(for Q/QnA projects)
System variable ranges for the actual project. Available if an Q/QnA project is open.
Word Range
D: D devices are used as word system variables.
R: R devices are used as word system variables.
W: W devices are used as word system variables.
Word range – From/to: PLC type dependant, as defined in the parameters.
Timers
Standard (T) – From/to: PLC type dependant, as defined in the parameters.
Retentive (ST) – From/to: PLC type dependant, as defined in the parameters.
Counters ©)
Counters – From/to: PLC type dependant, as defined in the parameters.
Bit range
M: M devices are used as bit system variables.
Bit range – From/to: PLC type dependant, as defined in the parameters.
Labels (P)
Labels – From/to: PLC type dependant, as defined in the adequate CNF file.
Step flags (S)
Step flags – From/to: PLC type dependant, as defined in the adequate TYP file.
Display Program Size: A summary of the used program size is displayed on a separate dialogue box. If the program is not compiled the dialogue shows a ‘?’ character instead of the program size. If SFC or SUB programs are not available for this CPU, the correspondent line will be grayed.
Display Used Ranges: A summary of the used system variable ranges is displayed on a separate dialogue box.
GX IEC Developer Reference Manual 2 – 51
Project specific options Installation
Fig. 2-45:
Project Options -
System Variables
(for A/FX projects)
2 – 52
System variable ranges for the actual project. Available if an A/FX project is open.
Word Range
D: D devices are used as word system variables.
R (A projects only): R devices are used as word system variables.
W (A projects only): W devices are used as word system variables.
Word range – From/to: PLC type dependant, as defined in the parameters.
Timers
100 ms (T) – From/to: PLC type dependant, as defined in the parameters.
10 ms (T) – From/to: PLC type dependant, as defined in the parameters.
Retentive (T) – From/to: PLC type dependant, as defined in the parameters.
Counters (C)
Counters – From/to: PLC type dependant, as defined in the parameters.
Bit Range
M: M devices are used as bit system variables.
Bit range – From/to: PLC type dependant
Labels (P)
Labels – From/to: PLC type dependant
Step flags (S) (FX projects only)
Step flags – From/to: PLC type dependant
Display Used Ranges: A summary of the used system variable ranges is displayed on a separate dialogue box.
MITSUBISHI ELECTRIC
Installation
2.10
Connecting the programmable controller (PLC) to the computer
Connecting the programmable controller (PLC) to the computer
In the Project Navigator click on PLC_Parameter and in the dialogue box on the button CPU
Type. You get a list containing all CPU types which are supported by GX IEC Developer. A
detailed summary of all CPU types supported by GX IEC Developer is included in section 5.16.
This manual does
not
include instructions for installing your controller hardware. Each controller system is supplied with documentation including comprehensive installation instructions.
There are a number of different options for connecting the PLC to your personal computer:
쎲 Via the CPU interface
쎲 Via the computer link modules
쎲 Via an Ethernet module
쎲 Via the USB interface
The transparent mode enables data transmission by modem between the personal computer, terminal and the PLC.
The options for selecting the connection type and setting the corresponding parameters can be found in the Online menu under Transfer Setup - Ports
(
The following figure on the next page shows all supported options for connecting the PLC to your personal computer.
GX IEC Developer Reference Manual 2 – 53
Connecting the programmable controller (PLC) to the computer Installation
GX IEC
Developer
Fig. 2-46:
System configuration
2 – 54
MITSUBISHI ELECTRIC
Installation
2.10.1
Connecting the programmable controller (PLC) to the computer
Connecting FX/FX
2
/FX
U
/FX
2U
/FX
2C
series controllers
The controllers of the FX series can only be connected to the computer via the CPU interface.
a) Connection via the CPU interface with the SC-09 interface converter
Connect the 9-pin D-shell connector to the computer. If your computer port has a 25-pin connector you will also need a 9/25-pin adapter. Connect the 25-pin D-shell connector to the
FX controller.
GX IEC
Developer
Fig. 2-47:
CPU interface connection
SC-09
SC-09
MELSEC FX/
FX2/FXU/
FX2U/FX2C b) Connection via the CPU interface with the FX-232AW serial interface
You will need two additional cables for connecting the FX-232AW module:
쎲 FX-422CAB for connecting the FX controller to the FX-232AW
쎲 F2-232CAB or FX-232CAB for connecting the FX-232AW to the personal computer
If your computer port has a 9-pin connector you will also need a 25/9-pin adapter as both of these cables (F2-232CAB, FX-232CAB) are fitted with 25-pin D-shell connectors at the PC end.
Fig. 2-48:
CPU interface connection
GX IEC
Developer
F2-232CAB
FX-232CAB
MELSEC FX/FX2/
FXU/FX2U/FX2C
FX-422CAB
GX IEC Developer Reference Manual 2 – 55
Connecting the programmable controller (PLC) to the computer
2.10.2
Installation
Connecting FX
0
/FX
0N
/FX
0S
/FX
1S
/FX
1N
/FX
2N
/FX
2NC
series controllers
The controllers of the FX series can only be connected to the computer via the CPU interface.
a) Connection via the CPU interface with the SC-09 interface converter
Connect the 9-pin D-shell connector to the computer. If your computer port has a 25-pin connector you will also need a 9/25-pin adapter. Connect the 8-pin min-DIN connector to the
FX controller. This connector is delivered together with the SC-09.
GX IEC
Developer
Fig. 2-49:
CPU interface connection
MELSEC FX0/FX0N/FX0S/
FX1S/FX1N/FX2N
SC-09
b) Connection via the CPU interface with the FX-232AW serial interface
You need three additional cables for connecting the systems with the FX-232AW module:
쎲 The FX-422CAB and the FX-20PCADP cables for connecting the FX controller to the
FX-232AW
쎲 The F2-232CAB or FX-232CAB cable for connecting the FX-232AW to the personal computer
If your computer port has a 9-pin connector you will also need a 25/9-pin adapter, as both these cables (F2-232CAB, FX-232CAB) have 25-pin D-shell connectors at the computer end.
GX IEC
Developer
Fig. 2-50:
CPU interface connection
F2-232CAB
FX-232CAB
FX-422CAB FX-20PCADP
MELSEC FX0/FX0N/FX0S/
FX1S/FX1N/FX2N
2 – 56
MITSUBISHI ELECTRIC
Installation
2.10.3
Connecting the programmable controller (PLC) to the computer
Connecting FX3U series controllers
a) Connection of the CPU interface via the FX-232AWC-H
You can use two additional cables for connecting the CPU and the PC:
쎲 The FX-422CAB0 cable for connecting the FX3U controller to the FX-232AWC-H
The FX-422CAB0 cable can be connected to the FX3U via the programming port
(PP Port) or via the extension board FX3U-422-BD.
쎲 The F2-232CAB-1 cable for connecting the FX-232AWC-H to the personal computer
FX-232AWC-H
FX3U
Fig. 2-51:
CPU interface connection
PC F2-232CAB-1
FX-422CAB0
PP Port
FX3U
PC F2-232CAB-1
FX-232AWC-H
FX-422CAB0
FX3U-422-BD
b) Connection of the CPU interface via the FX-232CAB-1 cable
You can use the FX-232CAB-1 cable for connecting the CPU and the PC:
쎲 The FX-232CAB-1 cable can be connected to the FX3U via the extension board
FX3U-232-BD.
쎲 The FX-232CAB-1 cable can be connected to the FX3U via the special function module
FX3U-232-ADP.
FX3U-232-BD
FX3U
Fig. 2-52:
CPU interface connection
FX-232CAB-1
PC
FX3U-232-ADP
FX3U
PC
FX-232CAB-1
GX IEC Developer Reference Manual 2 – 57
Connecting the programmable controller (PLC) to the computer Installation
c) Connection of the CPU interface via an USB cable
You can use an USB cable for connecting the CPU and the PC:
쎲 The USB cable can be connected to the FX3U via the extension board FX3U-USB-BD.
쎲 The USB cable can be connected to the FX3U via the connection adapter FX-USB-AW.
FX3U-USB-BD
FX3U
Fig. 2-53:
CPU connection via USB cable
USB cable
PC
FX3U-USB-AW
FX3U
PC
USB cable
d) Connection of the CPU interface via modem
You can use modems for connecting the CPU and the PC:
쎲 The CPU side modem can be connected to the FX3U via the extension board
FX3U-232-BD.
쎲 The CPU side modem can be connected to the FX3U via the special function module
FX3U-232-ADP.
FX3U-232-BD
FX3U
Fig. 2-54:
CPU connection via modem
Modem
Modem
PC
FX3U-232-ADP
FX3U
Modem Modem
PC
2 – 58
MITSUBISHI ELECTRIC
Installation Connecting the programmable controller (PLC) to the computer
e) Connection of the CPU interface via HMI module
You can use HMI modules for connecting the CPU and the PC:
쎲 The FX3U can be connected to the PC via a GOT-F900.
The CPU is connected to the GOT-F900 by the FX-50DU-CAB0 cable via the programming port (PP Port).
The PC is connected to the GOT-F900 by the FX-232CAB-1 cable.
쎲 The FX3U can be connected to the PC via a GOT-1000.
The CPU is connected to the GOT-1000 by the GT01-C
씲R4-8P cable via the programming port (PP Port).
The PC is connected to the GOT-1000 by the GT01-C30R2-9S cable or the
GT08-C20USB-5P cable.
GOT-F900
FX3U
Fig. 2-55:
CPU connection via HMI module
FX-232CAB-1
PC FX-50DU-CAB0
FX-422CAB0
GOT1000
PP Port
FX3U
PC
GT01-C30R2-9S
(RS232)
GT01-C
쏔R4-8P
(RS422)
PP Port
GOT1000
PC
GT08-C20USB-5P
(USB)
GT01-C
쏔R4-8P
(RS422)
PP Port
GX IEC Developer Reference Manual 2 – 59
Connecting the programmable controller (PLC) to the computer Installation
f) Connection of the CPU interface via the ETHERNET
You can connect the CPU to the PC via the ETHERNET:
쎲 The FX3U can be connected to the ETHERNET via the special function module
FX3U-ENET.
FX3U
FX3U-ENET
FX2NC-ENET-ADP
FX2NC
Fig. 2-56:
CPU connection via ETHERNET
PC
PC
2 – 60
MITSUBISHI ELECTRIC
Installation
2.10.4
Connecting the programmable controller (PLC) to the computer
Connecting A/QnA series controllers
The A series controllers can be connected to the computer via either the CPU interface, computer link module, the A7BDE interface card or the Ethernet module.
a) Connection via the CPU interface with the SC-09 interface converter
Connect the 9-pin D-shell connector of the SC-09 to the computer. If your computer's port has a 25-pin connector you will also need a 25/9-pin adapter. Connect the 25-pin D-shell connector to the CPU port.
GX IEC
Developer
Fig. 2-57:
CPU interface connection
A/QnA-
CPU
SC-09 b) Connection via the computer link module
The following computer link modules are available: AJ71UC24, A1SJ71UC24-R2,
AJ71QC24(-R), AJ71QC24N(-R2), A1SJ71QC24(-R2), A1SJ71QC24N(-R2). The computer link module is installed in the base unit (module rack). Connect the RS-232 interface of your computer to the RS-232 port of the computer link module via the interface cable. Check the pin assignments of the cable before using it (see below). The communications parameters you set in Online - Transfer Setup - Ports (
Þ Section 8.3.1) must match the DIP switch settings on
the computer link modules.
GX IEC
Developer
Fig. 2-58:
Computer link connection
A/QnA-
CPU
A**J71*C24
AC30N2A
NOTE
See the computer link module manuals for full details on their settings.
GX IEC Developer Reference Manual 2 – 61
Connecting the programmable controller (PLC) to the computer Installation
Pin assignments of the RS-232 interface cable
The pin assignments of 25-pin connectors with applicable CD signal on pin 8 are as follows:
Computer Link Module
Signal
FG
SD (TXD)
Pin
1
2
RD (RXD)
RS
CS (CTS)
DSR (DR)
SG
5
6
3
4
7
CD
DTR (ER)
8
20
Cable Connection and Signal
Direction (Full-/Half-Duplex)
앴앶앶앶앸
앶앶앶앶앸
앴앶앶앶앶
앴앶앶앶앸
앴앶앶앶앶
앴앶앶앶앸
앴앶앶앶앸
앶앶앶앶앸
5
6
7
4
8
20
GX IEC Developer
Pin
1
3
Signal
FG
RD (RXD)
2 SD (TXD)
CD
DTR (ER)
SG
RS
CS (CTS)
DSR (DR)
Tab. 2-7:
Pin assignments of the RS-232 interface cable (25-pin, with CD signal)
DC code control or DTR/DSR control is enabled by connecting the computer link module to an external device as shown above.
The pin assignments of 25-pin connectors without applicable CD signal on pin 8 are as follows:
Computer Link Module
Signal Pin
FG
SD (TXD)
1
2
RD (RXD)
RS
CS (CTS)
DSR (DR)
3
4
5
6
SG
CD
DTR (ER)
7
8
20
Cable Connection and Signal
Direction (Full-Duplex)
앴앶앶앶앸
앶앶앶앶앸
앴앶앶앶앶
앴앶앶앶앶
앴앶앶앶앸
앶앶앶앶앸
7
8
6
2
4
5
20
1
3
GX IEC Developer
Pin Signal
FG
RD (RXD)
SD (TXD)
RS
CS (CTS)
DTR (ER)
SG
CD
DSR (DR)
Tab. 2-8:
Pin assignments of the RS-232 interface cable (25-pin, no CD signal)
DC code control or DTR/DSR control is enabled by connecting the computer link module to an external device as shown above.
2 – 62
MITSUBISHI ELECTRIC
Installation Connecting the programmable controller (PLC) to the computer
The pin assignments of 9-pin connectors with applicable CD signal on pin 1 are as follows:
Computer Link Module
Signal Pin
CD
RD (RXD)
SD (TXD)
DTR (ER)
SG
DSR (DR)
RS (RTS)
CS (CTS)
6
7
4
5
8
1
2
3
Cable Connection and Signal
Direction (Full-/Half-Duplex)
앴앶앶앶앸
앴앶앶앶앶
앶앶앶앶앸
앶앶앶앶앸
앴앶앶앶앸
앴앶앶앶앶
6
5
4
8
3
2
GX IEC Developer
Pin
7
Signal
RS (RTS)
CS (CTS)
SD (TXD)
RD (RXD)
DSR (DR)
SG
DTR (ER)
앴앶앶앶앸
1 CD
Tab. 2-9:
Pin assignments of the RS-232 interface cable (9-pin, with CD signal)
DC code control or DTR/DSR control is enabled by connecting the computer link module to an external device as shown above.
The pin assignments of 9-pin connectors without applicable CD signal on pin 1 are as follows:
Computer Link Module
Signal Pin
CD
RD (RXD)
1
2
SD (TXD)
DTR (ER)
SG
DSR (DR)
RS
CS (CTS)
5
6
7
8
3
4
Cable Connection and Signal
Direction (Full-Duplex)
앴앶앶앶앶
앶앶앶앶앸
앶앶앶앶앸
앴앶앶앶앸
앴앶앶앶앶
5
4
7
8
2
6
1
3
GX IEC Developer
Pin Signal
CD
SD (TXD)
RD (RXD)
DSR (DR)
SG
DTR (ER)
RS
CS (CTS)
Tab. 2-10: Pin assignments of the RS-232 interface cable (9-pin, no CD signal)
DC code control or DTR/DSR control is enabled by connecting the computer link module to an external device as shown above.
GX IEC Developer Reference Manual 2 – 63
Connecting the programmable controller (PLC) to the computer Installation
NOTE
DIP switch settings
The communications parameters you set in Online - Transfer Setup - Ports
(
Þ Section 8.3.1) must match the DIP switch settings on the computer link modules.
Please see the manual of the computer link module for details on the DIP switch settings.
c) Connection via the Ethernet module
GX IEC Developer enables a MELSEC A series' PLC to be programmed via the Ethernet.
The Ethernet module is installed in the base unit. The connection between the Personal
Computer and the Ethernet module is realized via the coaxial cable 10BASE5 (Ethernet) or
10BASE2 (Cheapernet).
The following Ethernet modules can be used:
쎲 AJ71E71-S3
쎲 AJ71QE71
쎲 A1SJ71E71-S3
쎲 A1SJ71QE71
쎲 AJ71E71N-B2
쎲 AJ71QE71N-B2
쎲 A1SJ71E71N-B2
쎲 A1SJ71QE71N-B2
쎲 AJ71E71N-B5T
쎲 AJ71QE71N-B5T
쎲 A1SJ71E71N-B5T
쎲 A1SJ71QE71N-B5T
GX IEC
Developer
Fig. 2-59:
Ethernet connection
A/QnA-
CPU
A**J71*E71
ETHERNET
Cheapernet
NOTES
The communications parameters you set in Online - Transfer Setup - Ports
(
Þ Section 8.3.1) must match the DIP switch settings on the Ethernet module.
See Ethernet manuals for full details on Ethernet module settings.
The Ethernet modules will only work together properly with GX IEC Developer, if its version
“E” (or higher) is used.
You will find the version number directly on the Ethernet modules.
When the AnU CPU type has been started on the personal computer, change the PLC type to the AnA CPU.
Communications can only be performed within the same segment.
Communications can not be performed via the router or gateway.
2 – 64
MITSUBISHI ELECTRIC
Installation
2.10.5
Connecting the programmable controller (PLC) to the computer
Connecting Q series controllers
The Q series controllers can be connected to the computer via either the CPU interface
(RS-232 or USB), computer link module or the Ethernet module.
a) Connection via the CPU interface with the QC30R2 interface cable
Connect the RS-232 interface of your computer to the RS-232 port of the CPU via the interface cable QC30R2. If your computer's port has a 25-pin connector you will also need a 25/9-pin adapter.
GX IEC
Developer
Fig. 2-60:
CPU interface connection
Q CPU
QC30R2 b) Connection via the computer link module
The computer link module QJ71C24(-R2) is installed in the base unit (module rack). Connect the RS-232 interface of your computer to the RS-232 port of the computer link module via the interface cable AC30N2A. Check the pin assignments of the cable before using it (see below).
The communications parameters you set in Online - Transfer Setup - Ports (
must match the DIP switch settings on the computer link modules.
GX IEC
Developer
Fig. 2-61:
Computer link connection
Q CPU QJ71C24
AC30N2A
NOTE
Please see the manual of the computer link module for details on the DIP switch settings.
GX IEC Developer Reference Manual 2 – 65
Connecting the programmable controller (PLC) to the computer Installation
Pin assignments of the RS-232 interface cable
The connector specifications are indicated below:
Pin Signal Description
1
6
7
8
4
5
2
3
9
CD
RD (RXD)
SD (TXD)
DTR (ER)
SG
DSR (DR)
RS
CS (CTS)
RI (CI)
Receive carrier detection
Receive data
Send data
Data terminal ready
Send ground
Data set ready
Request to send
Clear to send
Call indication
Tab. 2-11: Pin assignments of the RS-232 interface cable
Signal Direction,
Q-compatible C24 <->
External Device
앴앶앶앶앶
앴앶앶앶앶
앶앶앶앶앸
앶앶앶앶앸
앴앶앶앶앸
앴앶앶앶앶
앶앶앶앶앸
앴앶앶앶앶
앴앶앶앶앶
The pin assignments of 9-pin connectors with applicable CD signal on pin 1 are as follows:
Computer Link Module
Signal Pin
CD
RD (RXD)
SD (TXD)
DTR (ER)
SG
DSR (DR)
RS (RTS)
CS (CTS)
5
6
7
3
4
1
2
8
Cable Connection and Signal
Direction (Full-/Half-Duplex)
앴앶앶앶앸
앴앶앶앶앶
앶앶앶앶앸
앶앶앶앶앸
앴앶앶앶앸
앴앶앶앶앶
앴앶앶앶앸
2
6
8
3
5
4
GX IEC Developer
Pin
7
Signal
RS (RTS)
CS (CTS)
SD (TXD)
RD (RXD)
DSR (DR)
SG
DTR (ER)
1 CD
Tab. 2-12: Pin assignments of the RS-232 interface cable (9-pin, with CD signal)
DC code control or DTR/DSR control is enabled by connecting the computer link module to an external device as shown above.
2 – 66
MITSUBISHI ELECTRIC
Installation Connecting the programmable controller (PLC) to the computer
NOTE
The pin assignments of 9-pin connectors without applicable CD signal on pin 1 are as follows:
Computer Link Module
Signal
CD
Pin
1
RD (RXD)
SD (TXD)
DTR (ER)
2
3
4
SG
DSR (DR)
RS
CS (CTS)
5
6
7
8
Cable Connection and Signal
Direction (Full-Duplex)
앴앶앶앶앶
앶앶앶앶앸
앶앶앶앶앸
앴앶앶앶앸
앴앶앶앶앶
5
4
7
8
3
2
6
GX IEC Developer
Pin
1
Signal
CD
SD (TXD)
RD (RXD)
DSR (DR)
SG
DTR (ER)
RS
CS (CTS)
Tab. 2-13: Pin assignments of the RS-232 interface cable (9-pin, no CD signal)
DC code control or DTR/DSR control is enabled by connecting the computer link module to an external device as shown above.
DIP switch settings
The communications parameters you set in Online - Transfer Setup - Ports
(
Þ Section 8.3.1) must match the DIP switch settings on the computer link modules.
Please see the computer link module manual for details on the DIP switch settings.
c) Connection via the Ethernet module
GX IEC Developer enables a MELSEC Q series' PLC to be programmed via the Ethernet.
The Ethernet module QJ71E71(-B2) is installed in the base unit. The connection between the
Personal Computer and the Ethernet module is realized via the coaxial cable 10BASE5
(Ethernet) or 10BASE2 (Cheapernet).
GX IEC
Developer
Fig. 2-62:
Ethernet connection
Q CPU QJ71E71
ETHERNET
Cheapernet
NOTE
See Ethernet manuals for full details on Ethernet module settings.
The communications parameters you set in Online - Transfer Setup - Ports
(
Þ Section 8.3.1) must match the DIP switch settings on the Ethernet module.
GX IEC Developer Reference Manual 2 – 67
Connecting the programmable controller (PLC) to the computer Installation
d) Connection via the CPU interface with a QC30-USB cable
The USB port of the computer is connected to the USB port (not on Q00(J), Q01, Q02 CPUs) of the CPU via a QC30-USB connection cable.
GX IEC
Developer
Fig. 2-63:
CPU interface connection
Q CPU
QC30-USB
Cable
NOTES
Connecting/disconnecting the USB cable, resetting the PLC, or switching power OFF/ON frequently during communications with the PLC can cause a communications error, from which recovery may not be made.
Hence, place GX IEC Developer in an offline status where possible before connecting/ disconnecting the USB cable, resetting the PLC, or switching power OFF/ON.
If recovery cannot be made from the communications error, completely disconnect the USB cable once and reconnect it after more than five seconds. (Even after this operation, an error may occur at the initial communication, but communications will be made properly at the second time and later.)
Offline status: Indicates the status other than PLC write/read, monitor, test and PLC diagnostic.
When the PLC CPU is reset while communicating with the PLC CPU via USB connection in the Windows
약
2000 environment the message “Unsafe Removal of Device” is displayed.
In this case restart the communication with the PLC CPU after resetting the PLC CPU.
2 – 68
MITSUBISHI ELECTRIC
Installation
2.11
Supported utility packages for the Q series
Supported utility packages for the Q series
The following utility packages for the Q series are available:
쎲 SWnD5C-QADU-E for A/D Conversion Modules
쎲 SWnD5C-QCTU-E for High Speed Counter Modules
쎲 SWnD5C-QDAU-E for D/A Conversion Modules
쎲 SWnD5C-QSCU-E for Q Corresponding Serial Communication Modules
쎲 SWnD5C-QTCU-E for Temperature Control Modules
쎲 SWnD5C-QDNU-E for DeviceNet Master/Slave Modules
쎲 SWnD5C-QTIU-E for Thermocouple Input Modules
쎲 SWnD5C-QPTU-E for Positioning Control Modules
쎲 SWnD5C-QMBU-E for MODBUS
®
/TCP Interface Modules
쎲 SWnD5C-QASU-E for AS-i Master Modules
쎲 SWnD5C-QFLU-E for FL-net (OPCN-2) Interface Modules
2.12
Connecting a printer
Install your printer, following the manufacturer's instructions.
The Windows User's Guide contains detailed instructions on installing printers, printer drivers, additional fonts, the print options and using the Windows Print Manager.
In GX IEC Developer, you can access the printer setup options by selecting Printer Setup in the Project menu.
GX IEC Developer Reference Manual 2 – 69
Connection between PC and PLC via Modem
2.13
Installation
Connection between PC and PLC via Modem
The connection between a PC and a PLC via telephone network using GSM and/or analogue modems can be set up as following:
7 8
4 5
1 2
5
9
6
3
.
ç
è
ü
MITSU BISH I
A
Fig. 2-64:
Connection between PC and PLC via modem
2 – 70
A62PE U Q 2AC PU
AJ71Q BR11
AJ71Q E 71-B5
Q 00JC PU
MITS U B IS H I
MO D E
RU N
E R R .
I / 01
I / 02
I / 03
E.S.D
I / 04
P ULL
R S -232
MITSUBISHI ELECTRIC
Installation Installing the USB Driver
2.14
NOTE
2.14.1
Installing the USB Driver
When Windows
약
2000 Professional, Windows
약
XP Professional or Windows
약
XP Home
Edition is used, the USB driver must be installed to make CPU USB communication. The following is the USB driver installation procedure.
If the USB driver cannot be installed, check the following setting.
When Windows
약
2000 Professional is used
If you have selected "Block-Prevent installation of unsigned files" after [ControlPanel] -
[System] - [Hardware] - [Driver Signing], the USB driver may not be installed. Choose
"Ignore-Install all files, regardless of file signature" or "Warn-Display a message before installing an unsigned file" for [Driver Signing], and install the USB driver.
When Windows
약
XP Professional or Windows
약
XP Home Edition is used
If you have selected "Block-Never install unsigned driver software" after [ControlPanel] -
[System] - [Hardware] - [Driver Signing], the USB driver may not be installed. Choose
"Ignore-Install the software anyway and don't ask for my approval" or "Warn-Prompt me each time to choose an action" for [Driver Signing], and install the USB driver.
When Windows 2000 Professional is used
The following indicates the procedure for installing the USB driver when using Windows
약
2000
Professional.
햲 The screen shown below appears when you connect the personal computer and
Q CPU (Q mode) by the USB cable. Click the button Next.
Fig. 2-65:
Welcome to the Found New Hardware
Wizard
햳 Choose "Search for a suitable driver for my device (recommended)" and click the button Next.
Fig. 2-66:
Install Hardware Device Drivers
GX IEC Developer Reference Manual 2 – 71
Installing the USB Driver
햴 Check Specify a location and click the button Next.
Fig. 2-67:
Locate Driver Files
Installation
햵 As the screen below appears, set the product installation destination
"Easysocket\USBdrivers" and click the button Next.
The screen shown below shows the example of setting
C:\MELSEC\Easysocket\USBdrivers.
Fig. 2-68:
Copy manufacturer's files
햶 The screen below appears to indicate completion of installation. Click the button Finish to terminate installation.
Fig. 2-69:
Completing the Found New Hardware
Wizard
2 – 72
MITSUBISHI ELECTRIC
Installation
2.14.2
Installing the USB Driver
When Windows XP Professional and Windows XP Home Edition is used
The following indicates the procedure for installing the USB driver when using Windows
약
Professional or Windows
약
XP Home Edition.
XP
햲 The screen below appears when you connect the personal computer and Q CPU
(Q mode) by the USB cable.
Choose "Install from a list or specific location [Advanced]" and click the button Next.
Fig. 2-70:
Welcome to the Found New Hardware
Wizard
햳 As the screen below appears, choose "Include this location in the search".
Check "Include this location in the search" and set "Easysocket\USBDrivers" of the folder where GX IEC Developer was installed.
After setting, click the button Next. The screen shown below shows the example of setting
C: \MELSEC\Easysocket\USBDrivers.
Fig. 2-71:
Search and installation options
NOTE
If you use Windows
약
XP Professional and Windows
약
XP Home Edition with ServicePack 2, please select the option “Don’t search. I will choose the driver to install.” in the dialogue window shown above. The automatic search does not work with ServicePack 2.
Then select the USB driver from your installation root. If this is i.e. drive C, please select:
“C: \MELSEC\Easysocket\USBDrivers\ECUsbd.inf”
GX IEC Developer Reference Manual 2 – 73
Installing the USB Driver Installation
햴 As the screen below appears, click the button Continue Anyway.
Fig. 2-72:
Hardware installation warning
(Please see note on the following page.)
NOTE
Though the screen above appears during installation of the USB driver, we have confirmed that the USB driver operates properly using Windows
약
XP Professional or Windows
약
XP
Home Edition. (No problem will occur after installation of the USB driver.)
Click Continue Anyway to continue the installation of the USB driver.
햵 The screen below appears to indicate completion of installation.
Click the button Finish to terminate installation.
Fig. 2-73:
Completing the Found New Hardware
Wizard
2 – 74
MITSUBISHI ELECTRIC
Installation
2.14.3
Installing the USB Driver
When Windows Vista is used
The following indicates the procedure for installing the USB driver when using Windows
Vista
약
.
햲 The screen below appears when you connect the personal computer to a Q CPU
(Q mode) or a FX CPU by the USB cable.
Choose "Locate and install driver software (recommended)" and and wait until searching ends.
Fig. 2-74:
Welcome to the Found New Hardware
Wizard
NOTE
When the user account control is enabled, the following screen appears. Click the button
Continue to proceed.
Fig. 2-75:
User Account Control
햳 As the screen below appears, choose "Browse my computer for driver software
(advanced)".
Fig. 2-76:
Check for a solution
GX IEC Developer Reference Manual 2 – 75
Installing the USB Driver Installation
햴 The following screen appears. Set the installation location of GX IEC Developer,
"Easysocket\USBdrivers".
After setting, click the button Next. The screen shown below shows the example of setting C: \MELSEC\Easysocket\USBDrivers.
If multiple MELSOFT products have been installed, refer to the installation location of the first installed product.
Fig. 2-77:
Surch for driver software
햵 Now the screen below appears. Select "Install this driver software anyway".
Fig. 2-78:
Windows Security
햶 The following screen appears. Click the button Close.
Fig. 2-79:
Completing the Found New Hardware
Wizard
햷 The below screen appears when the installation ends. Click the Close to exit the setting.
Fig. 2-80:
MITSUBISHI Easysocket Driver installed
2 – 76
MITSUBISHI ELECTRIC
The User Interface
3 The User Interface
The illustration below shows the screen after loading a project. In this example, the PLC configuration, a header and a body have all been opened in separate windows.
쐃
쐇
쐋
쐏
쐄
쐂
쐊
쐆
씈
쐈
쐅
씉
쐉
쐎
Fig. 3-1:
User Interface
Item
쐎
쐅
쐈
쐂
쐆
쐊
쐉
씈
씉
쐃
쐇
쐋
쐏
쐄
Description
Application title bar
Menu bar
Toolbar
Dialogue box
Button
Declaration table
Object window
Vertical scrollbar
Editor (Body)
Maximise button
Minimise button
Status bar
Horizontal scrollbar
Project Navigator window
Tab. 3-1:
Explanation for User interface
GX IEC Developer Reference Manual 3 – 1
The Title Bar
3.1
The Title Bar
The title bar contains the name of the project and application, for example:
Garage - GX IEC Developer.
The User Interface
3.2
The Menu Bar
When you start GX IEC Developer only the following menus are displayed:
NOTE
3.2.1
The complete menu bar with all the GX IEC Developer menus is not displayed until you open or create a project. When you select one of the menu titles a drop-down list is displayed showing the menu commands and options. The menu structure and the available options are context-sensitive, changing depending on what you are currently doing in the program.
Options displayed in light grey are not currently available for selection.
A reference to the complete menu structure is provided at the end of this Reference Manual.
Menu Conventions
�
�
�
�
�
�
Item
쐃
쐇
쐋
쐏
쐄
쐂
Description
Press the key corresponding to the underlined letter in the menu name.
Menu commands followed by a triangle symbol branch to a submenu with additional command options, which is displayed as a pop-up menu box.
Depending on what you are doing, not all menu commands are available at all points in GX IEC
Developer. Menu commands displayed in light grey are currently unavailable.
Menu commands followed by three periods open dialogue boxes in which additional entries and selections must be made.
In some cases, key combinations can be used to activate commands directly, without opening the corresponding menu. When available, these key combinations are shown after the command in the menu.
A check mark in front of a menu option shows that this option is currently activated. To deactivate an activated option, simply select it again. The check mark disappears, indicating that the option is now inactive.
Tab. 3-2:
Menus conventions
3 – 2
MITSUBISHI ELECTRIC
The User Interface The Menu Bar
3.2.2
NOTE
Selecting menu commands
Using the mouse
햲 Point to the menu with the mouse pointer, click with the left mouse button and then click on the desired command in the drop-down list that appears.
Or:
Click on the appropriate tool icon in the toolbar.
Using the keyboard
햲 Press ¦ or to activate the menu bar.
햳 Move the highlight to the desired menu with the cursor keys ¤ and ¥, then select by pressing
«.
Or:
Press the key corresponding to the underlined letter in the menu name (e.g. L for the
Online menu).
햴 Move the highlight to the desired menu option in the drop-down list with the cursor keys
£ and ¢, then press « to select.
Or:
Some menu commands can be selected directly, irrespective of which menu is currently open, by pressing a key or key combination. These key combinations are shown after the menu commands in the drop-down menus (e.g.
¦ for Quit in the Project menu).
All the available key combinations for menu commands are listed in the Appendix B to
this manual.
GX IEC Developer Reference Manual 3 – 3
The Toolbar The User Interface
3.3
NOTE
The Toolbar
The toolbar enables you to select the most important menu commands directly by clicking on the corresponding icons. The toolbar is context-sensitive, i.e. different tool icons are displayed depending on what you are currently doing in GX IEC Developer. Tool icons can only be selected with the mouse.
When you start GX IEC Developer, only the icon for opening a project is displayed. You can switch the toolbar display on or off with the Toolbar option in the View menu.
A complete list of the available tools is provided at the end of this manual.
3.4
3.4.1
The Project Navigator Window and the Objects it contains
The Project Navigator window is the ‘control centre’ of GX IEC Developer. It contains all the objects belonging to the project you are working on. All operations on objects are executed through this window.
The Project Navigator window is not displayed until you open a project. Closing the window automatically closes the project it contains.
You can always activate the Project Navigator window via the menu item Navigator in the
Window menu.
Three different views can be selected for the project navigator via tabs below the navigator window:
Project, Calltree, Used by
The Project Navigator window is not displayed until you open a project. Closing the window automatically closes the project it contains.
Navigator views
Project
This view gives a total overview of the project. It contains all elements of the project.
Calltree
For this view, the corresponding root items are tasks or also POUs, if they are not related to a specific task. As subitems all used POUs are shown. Additionally, it can be defined per object, if used global variables should also be shown.
Used by
This view has exactly two root items. The first root item is the POU pool with its POUs as nodes.
Subitems of the POUs and global variables are always POUs calling respectively using the corresponding POU or global variable.
3 – 4
MITSUBISHI ELECTRIC
The User Interface The Project Navigator Window and the Objects it contains
3.4.2
NOTE
3.4.3
Objects in the Project Navigator window
The following standard objects are automatically generated in the Project Navigator window for every newly-created project:
쎲 The Library_Pool
쎲 The PLC Parameters
쎲 The Task_Pool
쎲 The DUT_Pool
쎲 Global Variables
쎲 The POU_Pool
For a detailed description of these objects please refer to chapter 4.
How objects are displayed in the Project Navigator window
The entries in the Project Navigator window are arranged hierarchically. The first level is the project. The entries for the standard objects are located on the second level, from which you can branch to lower levels where they exist.
The symbol [+] before an entry in the Project Navigator window shows that the entry has additional lower levels (e.g. [+] POU_Pool).
The symbol [–] before an entry in the Project Navigator window indicates that its subordinate levels can be ‘collapsed’ so that they are no longer visible (e.g. [–] POU_Pool). This does not apply for the entry that contains the project name, however.
How to display hidden Navigator hierarchy levels
햲 Double-click on the entry whose hidden levels you wish to display.
Or:
Select the entry and select the Expand command in the Tools menu.
Or:
Press the key combination [CTRL][+].
Or:
Select the entry and click on the Expand tool icon in the toolbar:
Fig. 3-2: Tool for expanding collapsed Navigator hierarchy levels
GX IEC Developer Reference Manual 3 – 5
The Project Navigator Window and the Objects it contains The User Interface
This expands the next level of the hierarchy in the Project Navigator window. These levels can, in turn, also contain hidden lower levels.
Fig. 3-3:
Some of the lower levels in the Project Navigator window are expanded.
NOTE
How to hide displayed Navigator hierarchy levels
햲 Double-click on the entry whose lower levels you wish to hide.
Or:
Select the entry and select Collapse in the Tools menu.
Or:
Press the key combination [CTRL][-].
Or:
Select the entry and click on the Collapse tool in the toolbar:
The selected level is collapsed and hidden from view.
There are two possible responses when you double-click on a POU name, depending on the settings in the MMP703.INI file and in the menu Extras - Options - Zoom Header/Body -
Navigator Zoom (
- Show/hide header and body in the Project Navigator window
- Open Header and body
How to display additional object information in the Navigator
When you open a new project the additional object information is displayed by default.
햲 Select the Extended Information - Navigator command in the View menu.
Useful additional information is then displayed after each entry in the Project Navigator window.
Information when ‘Extended Information - Navigator’ is not active:
쎲 Tasks: Priority, Event
쎲 POUs: Program class
쎲 Body: Programming language
3 – 6
MITSUBISHI ELECTRIC
The User Interface The Project Navigator Window and the Objects it contains
NOTE
Additional information when ‘Extended Information - Navigator’ is active:
All entries: Creation date and time
쎲 Task_Pool, DUT_Pool, POU_Pool: Number of entries
쎲 DUT, Global_Vars, Header: Number of variable entries
쎲 POU: Programming language of the program body
In the Sequential Function Chart editor you can activate and deactivate additional comments for steps with the menu View - Extended Information - SFC editor.
How to toggle between Symbolic Name and Address in LD/FBD
In LD and FBD you can switch between three different view modes:
쎲 Standard Mode
All variables are shown by their names.
쎲 Mitsubishi Address Mode
The variables are shown by their Mitsubishi address.
쎲 IEC Address Mode
The variables are shown by their IEC address.
To toggle the address view mode select View Mode in the menu View. Here you can select one of the three view modes. Alternatively you can click on Toggle or press
§¨M to toggle between the three view modes.
Fig. 3-4:
Menu View Mode
NOTES
This function is only for view purposes. All editing/finding/tracking etc. functionalities refer to variable names and not to addresses.
The selected mode is valid for the currently active editor window only and is not persistent.
When you close a window and open it again, the editor will be in Standard Mode again.
GX IEC Developer Reference Manual 3 – 7
The Project Navigator Window and the Objects it contains The User Interface
In Mitsubishi Address Mode/IEC Address Mode the address of a variable that is not yet known because the project has not been compiled yet, or the address cannot be evaluated for other reasons, the name is shown preceded by an asterisk (‘*’).
Fig. 3-5:
Example for an address not known
NOTES
In the case of an array element with non static index, i.e. the index part contains one or more indices that do not represent a number, the whole array range is shown in the view mode
Mitsubishi Address Mode/IEC Address Mode.
The address ranges are shown as <start address>–<end address>. To avoid long address range strings, the end address is shortened by the redundant first part, e.g.
쎲 D122-25
쎲 D100-152
쎲 %MW19.3.17.2-3
쎲 %MW19.3.17.2-18.3
For DUTs and ARRAY of DUTs no addresses but only symbolic names are shown, preceded by an asterisk (‘*’).
The following elements are not toggled and are shown by their symbolic names:
- Index Registers like „X0Z0"
- Constants (VAR_CONSTANT/VAR_GLOBAL_CONSTANT)
- Labels
3 – 8
MITSUBISHI ELECTRIC
The User Interface The Project Navigator Window and the Objects it contains
The address view mode of the following elements can be toggled by the View Mode function:
Element
simple variable array variable of simple type
DUT members
DUT members of Array of DUT element direct address
IEC-Type(s)
BOOL, DINT, DWORD, INT,
REAL, STRING[], TIME, WORD
ARRAY of
BOOL, DINT, DWORD, INT,
REAL, STRING[], TIME, WORD simple variable or array variable of simple type (see above) simple variable or array variable of simple type (see above)
—
Remark
array and array elements e.g. M16, K4M0, K4Y12 …
Tab. 3-3:
Elements that can be toggled
While the editor is in an address mode (Mitsubishi or IEC) it is in the read only mode. If you try to edit a variable the following message box will appear:
Fig. 3-6:
Message box
This message box is also shown when you perform a Find or Find & Replace action. If you selects Yes in the message box the editor is switched to standard mode and the edit operation is be performed, else the editor remains in the address mode and no change is made.
During a find operation in the view mode no change is made. The edit control that contains the found text is highlighted. In the address view mode not the found text is shown but the address is highlighted.
GX IEC Developer Reference Manual 3 – 9
The Project Navigator Window and the Objects it contains The User Interface
If you start tracking of a variable and there are editors in an address mode the following message box will appear.
Fig. 3-7:
Message box
If you select Yes in the message box, all editors are switched to standard mode before tracking is started, else the view modes are not changed and tracking starts immediately in the selected address view.
In Online-Mode you can also toggle between view modes.
3.4.4
NOTE
Editing objects
The objects at the lowest level of each branch can be opened for editing. These levels are not marked with [+] or [–] symbols (e.g. PLC_Parameter, Header, Body). Opening them displays either a dialogue box (e.g. PLC_Parameter) or an object window (e.g. Header).
Most operations, such as opening, copying and deleting, can be performed directly in the
Project Navigator window with key combinations. The corresponding menu commands are in
the Object menu. For details on working with objects, see chapter 4.
All key combinations used for working with objects and the Project Navigator are listed and
3 – 10
MITSUBISHI ELECTRIC
The User Interface
3.5
The Status Bar
The Status Bar
The status bar contains information on the current status of your project. You can enable or disable its display and the information it contains is also configurable. The command for switching the status bar display on and off is in the View menu.
How to configure the Status Bar
햲 Double-click in the status bar.
Or:
Select Configure Status bar in the View menu.
The following dialogue box is displayed:
Fig. 3-8:
Status bar configuration
Editor Info: Display the POU name and the number of variable entries in the header
Security Level: Display current security level
Online: Display online status
CpuType: Display the PLC CPU for which the project is configured
Conn Status: Display active connection to the PLC system: PLC state, current scan time.
Display depends on selection of monitoring mode and PLC status.
Error Status: Display PLC system error status.
Display depends on selection of monitoring mode and PLC status.
GuidedEditing: Display of the editing mode (OVR/INS)
Clock: Display time
Path: Directory path on which the current project is stored
System Resources: Free Windows system resources in %
Free Memory: Amount of available free memory (in bytes)
Redundant Info: For QnPRH PLCs only. The Status Bar will alternate between displaying the operating mode (“Backup” or “Separate”) and the identity of the connected PLC (“Control
(System A)” or “Backup (System B)” or any combination thereof) when Monitoring Mode is active. The interval between changes will depend on the poll rate set in Extras
Options
Monitor Mode (see section 2.8.10).
GX IEC Developer Reference Manual 3 – 11
The Status Bar The User Interface
NOTE
How to add status bar items
햲 Select the item to be displayed in the Possible Status Field list box.
햳 Click on the Add button to display the selected item in the Status bar.
햴 Repeat steps 햲 and 햳 for each additional item to be displayed in the status bar.
How to delete status bar items
햲 Select the item to be deleted in the Displayed fields list box.
햳 Click on the Delete button to delete the selected item from the Status bar..
햴 Repeat steps 햲 and 햳 for each item to be cleared from the status bar.
You can restore default status bar display settings at any time by clicking on the Defaults button.
3 – 12
MITSUBISHI ELECTRIC
The User Interface Working with Windows
3.6
NOTE
Working with Windows
This section only contains a short explanation of the various operations performed with screen windows. For detailed instructions and definitions of the terms used, please refer to the
Windows User’s Guide. The procedures used with windows in Windows applications programs are standardised and are not specific to GX IEC Developer.
The following window types are used in GX IEC Developer:
쎲 The Project Navigator window
쎲 Object Windows
쎲 Dialogue Boxes
Although it is possible to display several different windows on the screen simultaneously, only one window can be active for editing at any one time. The currently active window is identified by a coloured title bar.
Please note that you can only open and edit one project, in one Project Navigator window.
But you can start GX IEC Developer several times to open and edit more than one project at a time
3.6.1
NOTE
Object windows
How to open windows
햲 In the Project Navigator window, double-click on the name of the object whose window you wish to open.
Or:
Select the object in the Project Navigator window by moving the highlight with the cursor keys
£ and ¢, and then press « or select the Open command in the Object menu.
The program opens the object window and displays it to the right of the Project Navigator window. You can open several object windows at the same time.
When the object window of a body (header) is open you can open its header (body) with the
Open Header (Open Body) command in the Object menu.
How to select an open window
햲 Click anywhere in the window.
Or:
Select the desired window with the key combination
§©.
Or:
Choose the window to be selected from the list of open windows shown in the Window menu.
The title bar of a selected window is highlighted in color.
GX IEC Developer Reference Manual 3 – 13
Working with Windows The User Interface
NOTE
How to close a window
쎲 Double-click on the control menu box of the window you wish to close.
Or:
Select the Close command in the window’s control menu.
Or:
Select the window and press
§ to activate its control menu Close command.
Or:
Select the window and select the Close command in the Object menu.
The program will ask you if you want to save any editing changes before closing the object window.
You can close all opened windows at the same time with the Close All command in the
Window menu.
How to arrange windows without overlaps (tiling)
햲 Select the Tile Horizontally or Tile Vertically command in the Window menu.
The Project Navigator window is displayed on the left of the screen. The object windows are arranged horizontally or vertically. The size of the object windows depends on how many windows are currently open.
How to arrange windows with overlaps
햲 Select the Cascade command in the Window menu.
The Project Navigator window and all open object windows are overlapped across the screen so that all the title bars are visible, starting at the top left corner.
3.6.2
Changing window display size
Buttons
Minimise window
Restore window
Maximise window
Window or Full-size window
씮 Icon
Click on the Minimise button in the object window (in the upper right corner of the window title bar), or select Minimise in the window’s control menu.
You can move and position the icons anywhere on the screen. The Arrange Icons command in the Window menu arranges all the icons in a row at the lower edge of the screen.
Fig. 3-9:
The object window icons
3 – 14
MITSUBISHI ELECTRIC
The User Interface Working with Windows
NOTE
Icon Previous window size
Click on the Restore button of the icon you wish to open, or simply double-click on the icon.
Full-size window Previous window size
Click on the Restore button (in the upper right corner of the window title bar), or select the
Restore command in the control menu.
Window or Icon Full-size window
Click on the Maximise button (in the upper right corner of the window title bar), or select the
Maximise command in the control menu.
You can find a list of all the key combinations for working with windows in the Appendix B.
GX IEC Developer Reference Manual 3 – 15
Working with Windows
3.6.3
The User Interface
Dialogue boxes
Dialogue boxes are displayed whenever additional user input is required, for example when you select the menu commands that are followed by three periods
(e.g. Open … in the Project menu). In addition to asking you to make entries, dialogue boxes can also contain important information and warnings.
Fig. 3-10:
The PLC Parameter dialogue box
NOTE
How to select an open dialogue box
햲 Click anywhere within the dialogue box.
Or:
Select the desired box with the key combination
¦.
The title bar of a selected dialogue box is displayed with color shading.
How to close dialogue boxes
쎲 If you want to discard the entries or changes you have made in the box, double-click on the control menu button of the dialogue box.
Or:
Select the Close command from the dialogue box’s control menu.
Or:
Click on the Cancel button.
Or:
Press the
° key.
쎲 If you want to accept the entries in the dialogue box, click on the OK button.
Or:
Select the OK button and press the
« key.
You can find a list of all the key combinations for working with windows in the Appendix B.
3 – 16
MITSUBISHI ELECTRIC
The User Interface
3.7
3.7.1
3.7.2
Special Functions and Dialogs of Redundant PLC Systems
Special Functions and Dialogs of Redundant PLC
Systems
Rules for Redundant PLC Systems in Backup Mode
Depending on the accessibility of the PLCs in a redundant system the following rules apply for online operations.
쎲 If the system, which was selected as the target system in the menu Transfer Setup
Ports (see section 8.3.1), cannot be accessed:
– In all modes an error message will be displayed and the operation is aborted.
쎲 If the system, which was selected as the target system in the menu Transfer Setup
Ports (see section 8.3.1), can be accessed:
– In Debug mode the operation is executed on the target system.
– In Separate mode the operation is executed on the target system.
– In Backup mode, if the other system can also be accessed, a confirmation dialogue
(
씮 3.7.2) will be displayed in which the execution on the target and/or the other
system can be advised.
– In Backup mode, if the other system cannot be accessed, an error message will be displayed and the operation is aborted only for Online (Ex)Change. For other operations a confirmation dialogue (
씮 3.7.2) will be displayed in which the
execution on the target system can be advised.
Confirmation Dialogue in Backup Mode
Before executing specific operations in backup mode of a redundant system the following dialogue will be displayed. It shows the selected operation and the status of the redundant PLC system.
Fig. 3-11:
Confirmation Dialogue for allowed on both PLCs only
GX IEC Developer Reference Manual 3 – 17
Special Functions and Dialogs of Redundant PLC Systems The User Interface
Fig. 3-12:
Confirmation Dialogue for allowed on either the target or on both PLCs
Fig. 3-13:
Confirmation Dialogue if the other system is not accessible
3 – 18
If you choose Both on this dialogue (Fig. 3-11 and Fig. 3-12) the operation will be executed on
both systems.
If you choose Target (Fig. 3-12 and Fig. 3-13), the operation will only be executed on the
system specified in Transfer Setup. (For some functionalities this button will not be available.)
If you choose Cancel, the operation will not be executed on either system.
The following functionalities will use this dialogue with the Target button disabled (Fig. 3-11):
쎲 Download to PLC
쎲 Online Program (Ex)Change
쎲 Copy Program Memory to Flash ROM
쎲 Download Symbolic Information
쎲 Online Verify
쎲 Format Drive
쎲 Defragment Drive
쎲 PLC Clear 씮 All
쎲 PLC Clear 씮 Latch
MITSUBISHI ELECTRIC
The User Interface Special Functions and Dialogs of Redundant PLC Systems
The following functionalities will use this dialogue with the Target button enabled (Fig. 3-12):
쎲 New PLC Keyword
쎲 Delete PLC Keyword
If the PLC selected in Transfer Setup Ports is accessible, but the other system is not, the
dialogue shown in Fig. 3-13 will be displayed for the following operations. In this case the Both
button is disabled and the Target button is enabled.
쎲 Download to PLC
쎲 Copy Program Memory to Flash ROM
쎲 Download Symbolic Information
쎲 Online Verify
쎲 Format Drive
쎲 Defragment Drive
쎲 New PLC Keyword
쎲 Delete PLC Keyword
쎲 PLC Clear 씮 All
쎲 PLC Clear 씮 Latch
GX IEC Developer Reference Manual 3 – 19
Special Functions and Dialogs of Redundant PLC Systems
3.7.3
The User Interface
PLC Redundancy Mode
For the QnPRH PLCs it is possible to switch between Backup and Separate mode remotely.
The following dialogue is opened by Online PLC Redundancy Mode and shows the current status of both systems, and whether manual switching of the Control and Standby systems is possible. It also provides the functionalities System Switch and the Memory
Copy.
�
�
�
�
Fig. 3-14:
Redundancy Mode dialogue
�
�
�
NOTE
Item
쐃
쐇
쐋
쐏
쐄
쐂
쐆
Description
Status information of redundant PLC
Check to set Backup or Separate mode
Click to set desired mode
Click to re-read operating state information from the PLCs
Click to switch Control and Standby systems manually
Click to copy the program memory from the Control system to the Standby system
Click to close the dialogue
Tab. 3-4:
Details of the Redundancy Mode dialogue
The Set Operating Mode, System Switch and Memory Copy operations can only be executed if the control system is the currently connected system.
3 – 20
MITSUBISHI ELECTRIC
The User Interface Special Functions and Dialogs of Redundant PLC Systems
System Switch
The System Switch operation manually switches control and standby systems. After successfully executing system switch, the previous control system will become the standby system, and the previous standby system will become the control system. The System Switch functionality can only be executed if the appropriate special relay SM1592 is turned ON. If it is
OFF, the following dialogue will be displayed:
Fig. 3-15:
Confirmation dialogue for system switch
Memory Copy
The Memory Copy operation copies the program memory and the standard RAM from the control system to the standby system. If the special relay SM1598 is turned OFF, it will also copy the standard ROM. The following message will be displayed before executing this operation:
Fig. 3-16:
Confirmation dialogue for memory copy
GX IEC Developer Reference Manual 3 – 21
Customising the Screen Display
3.8
The User Interface
Customising the Screen Display
The View menu contains all the commands for customising the display for your personal needs.
Toolbar, Status Bar, Horizontal Scrollbar and Grid
You can switch these display elements on and off with the corresponding options in the View menu, or with the check boxes in the dialogue box that is displayed when you select the
Environment option.
Fig. 3-17:
The toolbar, status bar, horizontal scrollbar and the grid can be activated or deactivated with the check boxes in the Environment dialogue box.
Grid display is enabled.
The check mark in front of the menu command in the menu View identifies options that are currently enabled. When you deactivate an option the check mark is no longer displayed.
How to set the screen zoom factor
햲 Select the Zoom... command in the View menu.
햳 Select one of the four standard zoom factors: 50%, 75%, 100%, 150%.
In addition to these four standard zoom factors you can also enter your own screen display magnification by changing the display grid size setting.
햲 Select the Environment... command in the View menu.
햳 Enter a value between 4 and 128 in the Size of Grid field.
The standard zoom factors correspond to the following grid settings:
Zoom factor:
Zoom factor:
Zoom factor:
Zoom factor:
50%
75%
100%
150%
Grid size:
Grid size:
Grid size:
Grid size:
8
12
16
24
3 – 22
MITSUBISHI ELECTRIC
The User Interface Customising the Screen Display
How to select the screen font
Select the Font command in the View menu.
Choose the font and style you wish to use for the screen display.
Fig. 3-18:
Screen font selection
NOTE
All GX IEC Developer texts will be displayed in the selected font. You can use all the fonts installed in your Windows configuration.
The screen font setting is stored together with the project.
GX IEC Developer Reference Manual 3 – 23
Customising the Screen Display The User Interface
How to set the display colors
햲 Select the Colors command in the View menu.
햳 Select the screen element whose color you wish to change:
Background
Selection
Text
Selected Text
Read Only Text
Locked Text
Foreground
Monitoring
Errors
Shade Left Top
Shade Right Bottom
Grid
Browser Items
SFC Raster Elements
The Color dialogue box is displayed.
햴 Click on the color you want in the palette of basic colors.
Fig. 3-19:
Display color selection
NOTE
NOTE
The current color of the selected element is shown in the two-line palette below the basic colors palette.
You can also define your own custom colors. For details please refer to the Windows User’s
Guide. The colors settings are stored with the project.
How to save the current Workspace
햲 Select the Save Workspace command in the View menu.
This command only saves the size, arrangement and display of the opened windows - with the exception of the Project Navigator window - in the current workspace, ignoring the font and color settings. The workspace is saved with the project in the file WORKSPACE.SYS.
How to load a previously saved Workspace
햲 Select the Load Workspace command in the View menu.
This command automatically loads the settings stored with the Save Workspace command by loading the data from the WORKSPACE.SYS file.
3 – 24
MITSUBISHI ELECTRIC
The User Interface Customising the Screen Display
How to load the system defaults
햲 Select the System Defaults command in the View menu.
When you create a new project the following system defaults are always selected automatically:
쎲 Toolbar display enabled
쎲 Status bar display enabled
쎲 Horizontal scrollbar display enabled
쎲 Grid display enabled
쎲 Zoom factor: 100 %
쎲 Grid size: 16
쎲 Extended information display in Project Navigator enabled
쎲 Background: light grey, Selection: dark grey
쎲 Text: black
쎲 Selected Text: white
쎲 Read Only Text: dark grey
쎲 Locked Text: dark grey
쎲 Foreground: light grey
쎲 Monitoring: blue
쎲 Errors: red
쎲 Shade left top: white
쎲 Shade right bottom: dark grey
쎲 Grid: black
GX IEC Developer Reference Manual 3 – 25
Mouse and keyboard operation The User Interface
3.9
NOTE
Mouse and keyboard operation
All operations in GX IEC Developer can be performed both with the mouse and the keyboard.
In most cases, a single click with the left mouse button corresponds to the
´ key, and a double-click corresponds to the
« key.
The instructions below are primarily for working with the mouse, but special keyboard key combinations are also included. All the key combinations for working with tables and the
editors are listed in the Appendix B of this manual.
For full details on using the mouse in Windows please refer to Windows Fundamentals section in the Windows User’s Guide.
3.10
General editing functions
3.10.1
NOTE
Using menu or keyboard operations
Most of the commands in the Edit menu are identical in all Windows application programs.
You can find detailed explanations of these commands in your Windows User’s Guide.
How to cut, copy and delete data
햲 Select the element you wish to edit (see following pages):
쎲 Cell contents in a Declaration Table: Enable the editing mode in the cell and select the cell text.
쎲 Lines in a Declaration Table: Select one or more lines.
쎲 Entire networks in the editors: Select the network bar to the left of the network you wish to edit.
쎲 Ranges (instruction, operand, lines) in the Instruction List:Select the range to be edited.
쎲 Program elements in the graphical editors: Select the elements to be edited.
쎲 Program elements in the Sequential Function Chart Language: Select the elements to be edited. When you select a Step its corresponding Transition is automatically selected as well.
햳 Select the editing command you wish to execute in the Edit menu.
Or:
Press the corresponding key combination:
Cut
Copy
Delete
X
C
µ
E
WARNING:
Deletions are performed directly, without prompting for confirmation. If you inadvertently delete something you can restore the deleted data by selecting the Undo command in the Edit menu. However, please note that this only works if you execute
Undo directly after performing the deletion!
3 – 26
MITSUBISHI ELECTRIC
The User Interface General editing functions
NOTE
How to paste data
햲 Select the position at which you wish to insert an element:
쎲 Cell contents in a Declaration Table: Activate editing mode in the cell in which you wish to insert the text from the clipboard.
쎲 Lines in a Declaration Table: Select a cell in the line before which you wish to insert the lines from the clipboard, or select the lines you wish to overwrite with the data from the clipboard.
쎲 Entire networks in the editors: Select the network bar of the network before which you wish to insert the network stored in the clipboard.
쎲 Ranges (instruction, operand, lines) in the Instruction List: Position the cursor at the point at which you wish to insert the text from the clipboard.
쎲 Sequential Function Chart elements: Select the point in the sequence before which you wish to insert the data from the clipboard.
햳 Select Paste in the Edit menu.
Or:
Press the corresponding key combination:
Paste
§V
햴 Elements in the graphical editors: When you select the Paste command the mouse pointer changes to a plus sign symbol. Position the pointer at the location at which you wish to insert the elements from the clipboard.
Pasting Parameter data into a Q Remote I/O project from a non-Q Remote I/O project is not be supported. Pasting Parameter data into a non-Q Remote I/O project from a Q Remote I/O project is also not supported.
How to undo editing operations
햲 Select Undo or Redo in the Edit menu.
Or:
Press the corresponding key combination:
Undo
Redo
¦ BACKSPACE
§ BACKSPACE
Undo undoes the effects of the last editing operation.
Redo undoes the effects of the last Undo operation.
Global Search and Replace
The Search and Replace functions can now be used globally to search the entire project
(Edit - Find/Replace menu).
Fig. 3-20:
Search and replace dialogue
GX IEC Developer Reference Manual 3 – 27
General editing functions The User Interface
NOTE
Find in:
This option enables you to search and replace in
the entire project (All objects) individual objects selected in the Project Navigator the current editor only
Find What / Replace With:
You can enter the following elements as find/replace arguments:
쎲 Variable identifiers
쎲 Data types
쎲 Addresses
쎲 Sequential function chart language step names
쎲 Sequential function chart language transitions
쎲 POU names
Find options:
Match whole word only: Search the entire word only
Match case: Search and replace operation for text exactly as entered, with upper/or lower case characters
Search in comments: Activating this option extends the search and replace operation to comment texts
You can replace function blocks in the graphical editors but no check is performed. Also, the replace procedure cannot be reversed; the only way to restore the project to its original state is by not saving it and reloading the old version from the disk.
Find Next / Replace:
By pressing the button Find Next or Replace, the next matching item will be searched and highlighted.
When you selected the option Current editor only under Find in, and when the last matching item was found and the button Find Next or Replace is pressed again, the following dialogue will be shown.
Fig. 3-21:
Dialogue box
3 – 28
Confirm by pressing Yes. Selecting No will close the dialogue box.
MITSUBISHI ELECTRIC
The User Interface
3.11
3.11.1
Drag&Drop by mouse operation
Drag&Drop by mouse operation
Drag & Drop offers a more efficient way of editing which is based on mouse usage in comparison to the equivalent necessary lengthy and various menu commands concerning clipboard handling.
Basically there are two different kind of drag&drop actions which can be performed:
쎲 copy objects
쎲 move objects
Functional description and user interface
In GX IEC Developer, a drag operation is initiated, if the left mouse button is clicked and held down, while the mouse is moved. When the mouse button is released, the drop operation is executed. What happens then is very similar to copy/paste (resp. cut/paste).
We call the object(s), that are dragged (e.g. an object or a selection in the navigator) the dragged item(s). The context where the dragged items come from is called drag source, while the context, where the drop is executed is called drop target. More explanation on this will follow below.
The dragged item and the drop target can be in different instances, but not all contexts can be drag sources and/or drop targets.
When dragging objects over drop targets, the shape of the mouse cursor indicates which operation (copy or move) would be performed, when dropped over this very target: drop not possible on actual target copy move
For all objects (listed below) the decision between the two possible actions (copy or move) is made by the context, except for those drop targets that don’t support move actions such as the
EDM for instance. The action (copy or move), decided by the context is called default action.
The default action can be overruled by the CTRL or the SHIFT key:
쎲 Holding down the CTRL key, while a drop is executed, makes the drop result in a COPY operation.
쎲 Holding down the SHIFT key, while a drop is executed, makes the drop result in a MOVE operation.
Until the moment the object is dropped (releasing of the left mouse button) you can decide between the two methods by pressing or releasing the CTRL or the SHIFT key.
Pressing the ESC key after starting the drag & drop, but before executing the drop (ie. with the mouse button still pressed) aborts the current drag & drop action. CTRL and SHIFT must be released before pressing ESC, because these key combinations may have other effects (e.g.
CTRL+ESC brings up the Windows Start menu). When the drop is executed (the mouse button is released), the ESC key has no effect anymore, but the Undo functionality may be used.
After drop, the drop target editor gets the focus in its application instance.
Undo and Redo are window oriented, i.e. if the drag & drop operation involves two editors, the changes made in each editor may be undone by calling Undo in them separately. E.g. after a
move
operation between two editors, calling Undo in the drop target editor deletes the newly
GX IEC Developer Reference Manual 3 – 29
Drag&Drop by mouse operation The User Interface inserted object, while calling Undo in the drag source editor undeletes the moved object.
Moving an object in its own editor can be undone in one step (because it happened in the same window).
The following section describes the objects which are involved in the drag & drop process resp.
which objects can be dragged and which objects serve as valid dropping areas.
Furthermore the valid scope for the dragged objects will be discussed because this is the decisive factor whether a dragged object will be moved or copied on default. The scope is the area of an object, in which he is existing (e.g. POUs exist in the POU pool). If the scope of an object is left during a drag & drop operation (e.g. drag & drop a POU to another project or to a user library in a project), the default drag & drop operation (copy or move) may change.
Dragged objects and their valid scope inside one project
In general: If a dragged objects leaves its valid scope the default operation for the objects will be a COPY operation. For the other case the object is simply MOVED. A MOVE operation is not supported for these items if they are dragged out of the valid scope (SHIFT key has no effect).
Moreover, if multiple objects from different scopes are dragged together (e.g. a POU from the
POU pool and the GVL) only the COPY operation is supported. This is then exactly the same operation as if copy/paste would have been made between the same source and target.
The following list gives an overview.
Possible dragged items
POU
DUT
Task
Action
GVL
Local declarations (selected in a POU header editor)
Global declarations (selected in any GVL editor)
Global declarations (selected in any GVL editor)
IL network
LADDER network
FBD network
SFC elements
Selected Text
EDM
IL Text
MELSEC IL Text
Scope
POU pool
햲
DUT pool
햲
Task pool
햲
SFC POU
햳
Project or user library
햴
POU header declaration editor
GVL declaration editor
POU header declaration editor
IL body editor
LADDER body editor
FBD body editor
SFC body editor
Textual body editor
EDM declaration editor
IL-body editor
MELSEC IL body editor
Tab. 3-5:
Overview of possible dragged items
햲
POUs, DUTs and tasks cannot be moved in their respective scopes, because they are automatically sorted and therefore changing their order cannot be made by dragging. The copy operation however is supported also for their own scope, by holding down the CTRL key when dropping.
햳
Actions cannot be moved at all, only the copy operation is supported for them. The copy operation however is supported also for their own scope, by holding down the CTRL key when dropping.
햴
GVLs cannot be dropped in their own scope (neither the copy nor the move operation is supported). Outside their scope both operations are possible.
3 – 30
MITSUBISHI ELECTRIC
The User Interface
3.11.2
Drag&Drop by mouse operation
Valid dropping targets inside one project
After describing the items which can be dragged the following section will explain in detail where these items can be dropped to and which preconditions have to exist for dropping.
The following tables give an overview on the drag/drop mechanism inside one project. All drag/drop actions are only defined for the project view of the navigator.
Drag & Drop of objects in the navigator
Dragged item
POU
DUT
TASK
Action
GVL (a)
Mixed objects
Dropping target Action
Project
POU pool of project
POU pool of user library
Task
Item will be inserted into project
POU pool
Item will be inserted into project
POU pool
Item will be inserted into user library POU pool
Item will be inserted into the task.
The program is appended at the end of the program list.
Precondition
User needs WRITE access rights for the project and the POU pool
User needs WRITE access rights for the project and the POU pool
User needs WRITE access rights for the library and its POU pool
Task editor does not have to be opened.
User needs WRITE access rights for the task
MOVE action is not possible
WRITE access rights Project
DUT pool of project
DUT pool of user library
Project
Task pool
SFC POU
SFC action pool
Project
Item will be inserted into project
DUT pool
Item will be inserted into project
DUT pool
Item will be inserted into user library DUT pool
Item will be inserted into project
TASK pool
Item will be inserted into the action pool of the associated SFC POU
Library
GVL (b)
Project
WRITE access rights for the project and TASK pool
WRITE access rights to the SFC
POU and action pool
GVL entries of (a) will be inserted into the project GVL
GVL entries of (a) will be inserted into the user library GVL
GVL entries of (a) will be appended into the GVL (b)
Items will be inserted into the project
WRITE access rights
WRITE access rights
MOVE action is not possible
Tab. 3-6:
Drag & Drop of objects in the navigator
GX IEC Developer Reference Manual 3 – 31
Drag&Drop by mouse operation The User Interface
Drag & Drop of declarations
Dragged item
EDM entry
Local declarations
Global declarations
Dropping target Action
EDM Entry will be inserted as new copy
POU Declaration will be inserted into the associated header
POU body
Header in the navigator
EDM
Declaration will be inserted into the header
Entry will be inserted into the EDM
(in POUName.VarName format)
POU
POU body
Items will be declared as external local in the associated header with the appropriate class
(VAR_GLOBAL => VAR)
POU header (and
POU header editor)
Any GVL (and
GVL editor)
EDM
Items will be inserted into the GVL
Entry will be inserted into the EDM
Precondition
MOVE action is not possible
WRITE access rights
MOVE action is not possible
WRITE access rights
MOVE action is not possible
햲
햳
Tab. 3-7:
Drag & Drop of declarations
햲
Only those declarations will be inserted into the EDM that existed at the time the GVL was last compiled. If the GVL was not compiled yet, no declarations will be inserted into the EDM.
햳
Only those declarations will be inserted into the EDM that existed at the time the POU was last compiled. If the POU was not compiled yet, no declarations will be inserted into the
EDM.
Drag & Drop of body objects
Dragged item
IL network
MELSEC IL network
Ladder network
FBD network
SFC element
Selected text
Dropping target Action
IL POU body editor
Items will be inserted at that position where the insertion cursor will appear.
MELSEC IL POU body editor
Items will be inserted at that position where the insertion cursor will appear.
Ladder POU body editor
Items will be inserted at that position where the insertion cursor will appear.
FBD POU body editor
Ladder POU body editor
SFC POU body editor
Items will be inserted at that position where the insertion cursor will appear.
Items will be inserted at that position where the insertion cursor will appear.
Textual POU body editor
Items will be inserted at that position where the insertion cursor will appear.
Tab. 3-8:
Drag & Drop of body objects
Precondition
WRITE access rights
WRITE access rights
WRITE access rights
WRITE access rights
WRITE access rights
햲
WRITE access rights
햲
Single elements can’t be dragged; additional element(s) will be selected automatically in the same way as with the Copy operation (i.e. if only a step is selected its related transition(s) and step(s) will be selected and dragged with it automatically).
3 – 32
MITSUBISHI ELECTRIC
The User Interface
3.12
Working in tables
Working in tables
The following objects are managed and defined in tables:
쎲 Global Variables
쎲 Local Variables (Header)
쎲 Data Unit Types (structured data types)
쎲 Data Unit Variable Addresses
쎲 Tasks
To open the table object window, double-click on the corresponding object in the Project
Navigator window. If the object window of a body is already open you can open its header by selecting the Open Header command in the Object menu.
� � � �
NOTE
�
Fig. 3-22:
Global Variable List
Item
쐃
쐇
쐋
쐏
쐄
쐂
Description
Cell with the line number
Table cell
Global Variables Table
Table Column Headings
Type selection (dialogue box)
Down arrow (list box)
Tab. 3-9:
Variables table items
�
You cannot change the number or the arrangement of the columns. When you activate a new table only line 0 is shown, in which you can enter the first variable.
You can also copy all the entries from the global variables list to the header of a POU by using the clipboard. When you do this, the data fields are automatically placed in the correct columns.
GX IEC Developer Reference Manual 3 – 33
Working in tables
3.12.1
The User Interface
Editing in tables
How to select a table cell
햲 Click on the cell you wish to select.
Or:
Select the cell with the cursor keys.
Selected cells are identified with an outline box.
How to select a table line
햲 Click on the cell containing the line number.
Or:
Select any cell in the line and press the key combination
² or ¨¶.
The selected lines are highlighted in the display.
How to select multiple table lines
햲 Select the first line in the range to be selected:
Continuous range: Hold down the
¨ key and click on the last line of the range to be selected.
Or:
Hold down the
¨ key and extend the selection to the lines above or below the first selected line with the
£ or ¢ keys.
Selecting groups of individual lines: Hold down the
§ key and click on the lines you wish to select.
The selected lines are highlighted in the display.
How to activate editing mode
햲 Double-click on the cell in which you wish to edit.
Or:
Select the cell and press the
´ key.
Or:
Select a cell and type the text you wish to enter.
How to deactivate editing mode
햲 Click on another cell.
Or:
Press the
« key.
3 – 34
MITSUBISHI ELECTRIC
The User Interface Working in tables
NOTE
How to open a list box or dialogue box
햲 Double-click on the symbol on the right hand side of the cell.
햳 Select the appropriate entry from the list box or dialogue box.
Or:
햲 Select a cell with a symbol at its right hand side.
햳 Press the key combination ¦¢.
햴 Select the appropriate entry with the £ and ¢ keys, then press « to transfer the entry to the cell.
When editing mode is activated, the blinking text entry cursor appears in the cell and the background color of the cell changes.
All the key combinations for working with tables are listed in the Appendix B.
How to change column widths of the text part
햲 Position the mouse pointer on the dividing line between the headings of the columns.
The pointer changes to a double-headed arrow symbol.
햳 Hold down the left mouse button and move the shaded column divider line so that the column has the desired width.
Or:
Double-click the row header near the cell borders to autosize columns to fit the widest text.
How to change column widths of the button part
Position the mouse pointer near the division between the text and the button part. (There is no dividing line between in the header row between the two parts.)
The pointer changes to a double-headed arrow symbol.
Fig. 3-23:
Double-headed arrow symbol
햲 Hold down the left mouse button and move the shaded column divider line so that the column has the desired width.
How to insert a new line
햲 Select New Declaration in the Edit menu.
햳 Select the position at which the new line is to be inserted.
Top
Inserts a new line at the top of the table
Before
Inserts a new line directly before the selected line/cell
After
Bottom
Inserts a new line directly after the selected line/cell
Inserts a new line at the end of the table
Or:
햲 Select any cell in the last line of the table.
햳 Press the key combination ¨«.
The line numbering is automatically updated after the insertion operation.
GX IEC Developer Reference Manual 3 – 35
Working in tables The User Interface
Example
How to sort table entries
햲 Select Sort in the Tools menu.
햳 Select the sort key to be used for the alphabetical sort procedure:
Type
Sort by data type
Class
Identifier
Sort by class
Sort by identifier
Or:
Click on the appropriate column header. The column header contains a sort indicator.
Fig. 3-24:
Sort indicator
E
WARNING:
The table should not contain any empty lines.
NOTE
FUN and FB POU headers can’t be sorted either using the Tools -> Sort menu or by clicking the appropriate column header. This functionality is disabled intentionally as the order of
Input and Output variables for FUN and FB POUs is critical and can therefore not changed automatically.
쑶
3.12.2
Automatic copying of the contents of the preceding line into the new line (Autoincrement)
When a new line is entered in a declaration table the contents of the preceding line are automatically copied to the new fields. Identifiers and addresses are automatically incremented by 1.
3 – 36
Fig. 3-25:
Automatic copying and incrementing
This function is only available when the Incremental New Declarations option in the Extras -
Options - Editing - Declaration Editor menu is enabled.
If you also wish to include the contents of the Type and Comment fields you must also activate the Copy Comment and Type Fields option.
MITSUBISHI ELECTRIC
The User Interface
3.12.3
Working in tables
Export and Import of Excel files
The export and import of a spreadsheet to a file of Excel version, Excel 97, Excel 2000, or
Excel 2002 (BIFF8 format), is available. Export will always save the whole spreadsheet.
Importing will always append new declarations to the list, preserving any existing declarations.
Export to Excel
The export to Excel is done by selecting the Export to Excel command in the Tools menu.
Import from Excel
The import from Excel is done by selecting the Import from Excel command in the Tools menu.
During the import process the following checks are executed on the imported file:
쎲 The imported file will be checked if it contains the columns required by the current editor. If none of the required columns are present, the import process will be aborted. If some columns are missing, you will be given the choice to continue, but the missing fields will be left empty for all imported declarations.
쎲 If the imported file contains no declarations, the import process will be aborted.
쎲 If the imported file contains empty rows, you will be given a chance to discard the empty rows, or import them anyway.
쎲 All cells that contain longer text than is allowed by the actual field will be automatically truncated.
쎲 The validity of the imported declarations themselves will not be checked (eg. for syntax errors, type mismatches, duplicate names, etc.).
쎲 The imported file will be checked if it contains external variables. These variables will be skipped. A warning is shown to inform you.
Fig. 3-26:
Import warning when external variables exist
The affected editors and dialogues are:
쎲 Task editor
쎲 Data Unit Type editor
쎲 Global Variable List editor
쎲 POU Header editor
쎲 Data unit variable addresses dialogue
GX IEC Developer Reference Manual 3 – 37
Working in tables
3.12.4
Selecting data types in the declaration table
Fig. 3-27:
Data type selection
The User Interface
Libraries
All data types (incl. Libraries)
<Project> All data types in the project
Manufacturer_Lib Reserved for functions to be added later
Standard_Lib Reserved for functions to be added later
Type Class
Data type class
Simple Types: Simple data types
Data Unit Types: Structured data types (DUT)
Function Blocks: Reserved for functions to be added later
Types
All existing data types, depends on the selections in the previous list fields.
3 – 38
MITSUBISHI ELECTRIC
The User Interface Working in tables
3.12.5
Example
Automatic default data types in the declaration table
As soon as you enter an address the most likely data type for that address is automatically displayed in the Type column.
Entry: X1
Default type: BOOL
Entry: D1
Default type: INT
Fig. 3-28:
Default data types in declaration tables
쑶
GX IEC Developer Reference Manual 3 – 39
Working in the editors (Body)
3.13
The User Interface
Working in the editors (Body)
The body contains the actual code of the PLC program. To open the body’s object window, double-click on the Body entry in the Project Navigator window. If the object window of a header is already open you can open its body with the Open Body command in the Object window.
Fig. 3-29:
Program body in editor
�
Item
쐃
쐇
Description
Network bar
Editing area
Tab. 3-10: Body editor items
�
3 – 40
MITSUBISHI ELECTRIC
The User Interface Working in the editors (Body)
3.13.1
Networks
In the Sequential Function Chart, Ladder Diagram and Function Block Diagram languages, the PLC program is always divided into a number of logical program units referred to as
‘networks’. These networks are numbered consecutively and can be given network labels which can be used as destinations for jump (goto) instructions.
E
WARNING:
In the graphical editors (Ladder Diagram and Function Block Diagram) you can only program a maximum of one circuit in each network.
NOTE
How to enter a new network
햲 Select the New Network command in the Edit menu.
햳 Choose the position at which you wish to insert the network.
Top
Before
At the beginning of the program
Directly before the selected network
After
Bottom
MELSEC Before
Directly after the selected network
At the end of the program
Insert a MELSEC network directly before the selected network (only possible in Instruction List)
Or:
햲 Use the following tools:
Tool Description
Inserts a new network directly before the selected network.
Menu Item
Edit - New Network - Before
Inserts a new network directly after the selected network.
Edit - New Network - After
Shortcut
¦B
¦A
Tab. 3-11: Tools for inserting new networks
Or:
햲 Insert new networks directly in the Network List.
In MELSEC networks you can only use MELSEC programming instructions; you cannot use the IEC instructions. Also, you can only insert MELSEC networks in Instruction List programs (
GX IEC Developer Reference Manual 3 – 41
Working in the editors (Body) The User Interface
How to assign network labels
햲 Double-click on the network bar.
Or:
Activate selection mode, position the mouse pointer over the network bar with the cursor keys, and then press the
« key.
A dialogue box is displayed in which you can enter the network label and title:
Label: The label must be terminated with a colon (:) and must consist of a maximum of 8 characters (including the colon). In MELSEC networks you can also assign absolute labels. An absolute label is a specific pointer address, e.g. P20.
Title: This entry is optional. The title can have up to 20 characters.
Fig. 3-30:
Assigning network labels and titles
NOTE
NOTE
Network labels and titles can also be entered directly in the Network List.
Network labels can be used as jump destinations in your PLC program, using the JMP operator in the Instruction List language, and with the jump instruction in the Ladder Diagram and Function Block Diagram languages.
Label1Label1Remember that every network label uses one system label and that the total number of system labels is limited to a maximum of 256. Since system labels are also needed for other elements in GX IEC Developer, you should only define labels to networks to which you actually intend to perform a jump.
How to make the network area larger/smaller
햲 In select mode, position the mouse pointer on the lower horizontal edge of the network bar.
The pointer changes to a double-headed arrow symbol.
햳 Hold down the left mouse button and drag the dividing line up or down as required.
Or:
Press the
´ key. Hold down the ´ key and drag the dividing line up or down with the
£ and ¢ cursor keys.
When you release the mouse button or the
´ key the network is displayed in the new size.
You do not normally have to change network size manually as it is adjusted dynamically; when you enter program elements or text the network is automatically enlarged as required.
3 – 42
MITSUBISHI ELECTRIC
The User Interface Working in the editors (Body)
Managing networks
The Network List is a powerful tool that gives you a clear overview of each POU’s networks, enabling you to manage them easily and efficiently.
Fig. 3-31:
Network List
Select the Network List command in the Tools menu.
A list of all the networks with their labels and titles is shown on the left of the dialogue box displayed. The dialogue box contains the following buttons:
Insert: :
You will be prompted for the label and title of the new network. A new network is then inserted in the Network List and the body directly before the currently selected network.
Append:
You will be prompted for the label and title of the new network. A new network is then inserted in the Network List and the body as the last network.
Edit:
Edit the label and title of the currently selected network.
Cut:
Cuts the currently selected network, deleting it from the Network List and the body and inserting it in the clipboard.
Copy:
Copies the currently selected network to the clipboard.
Paste:
The network in the clipboard is inserted in the Network List and the body, directly before the currently selected network.
Delete:
Deletes the currently selected network without copying it to the clipboard. If you accidentally delete a network you can recover it by clicking on the Undo button.
However, please note that Undo only works if you execute it immediately after performing the Delete command!
Undo:
Undoes the effects of the last command.
Redo:
Undoes the effects of the last Undo command.
GX IEC Developer Reference Manual 3 – 43
Working in the editors (Body)
NOTE
The User Interface
Find:
Allows you to find specific network labels in your program. Please note that the search is case-sensitive and wildcard characters (? and *) are not supported.
Close:
Closes the dialogue box, accepting any changes made.
The standard Windows key combinations for Delete, Cut, Copy and Paste are not supported in this dialogue box! You can only perform these operations with the buttons in the box.
However, the key combinations are supported for editing labels and titles.
3 – 44
MITSUBISHI ELECTRIC
The User Interface
3.14
The ST editor
The ST editor
Operation of both the text editors – IEC Instruction List and MELSEC Instruction List – is similar to that of a normal word processor.
The Instruction List consists of a sequence of controller instructions. Each controller instruction must begin on a new line, and consists of an operator (operator, function or function block) and one or more operands/variables. The operator and the operand must be separated by a tab stop.
Fig. 3-32:
ST Editor
�
�
�
Fig. 3-33:
IEC Instruction List in text editor
� � �
GX IEC Developer Reference Manual 3 – 45
The ST editor The User Interface
NOTE
Item
쐃
쐇
�
�
�
�
Description
Network bar
Editing Area
Comment
Column for operand(s)
Operator column
MELSEC network
Tab. 3-12: Text editor items
See the chapter 6 for details on programming.
A detailed description on how to insert programming instructions and variables is given at the end of this chapter.
All key combinations for working in Instruction List language are described in the
3.14.1
Syntax colouring
While you are typing text in the ST editor the entered text is coloured depending on the kind of input. The following groups are distinguished.
쎲 Keywords
AND
BY
CASE
DO
ELSE
ELSIF
END_CASE
END_FOR
END_IF
END_REPEAT
END_WHILE
EXIT
FALSE
FOR
IF
MOD
NOT
OF
OR
REPEAT
RETURN
THEN
TO
TRUE
UNTIL
WHILE
XOR
3 – 46
MITSUBISHI ELECTRIC
The User Interface
쎲 Operators
/
+
<
<=
-
&
*
**
=
>
;
>=
쎲 Comments with the following syntax:
(* <comment> *)
쎲 Constant Numbers
IEC
400000, -100
16#FFFF
8#0745
2#01010101
1.2E-10
T#3h10s3ms
Mitsubishi
K400000, K-100
HFFFF
E1.2-10
Tab. 3-13: Constant Numbers
Type
decimal hexadecimal octal binary
REAL
TIME
The ST editor
NOTE
IEC constants could contain single underscore characters between the digits of a numeric literal (e.g. 1_2_3.4_5 for a REAL constant). IEC typed literals like DINT16#FF are not supported by GX IEC Developer.
TRUE and FALSE are coloured like other keywords.
쎲 Constant Strings
IEC
‘abc’
Mitsubishi
“abc”
Tab. 3-14:
Constant Strings
쎲 Variables
Any variable or variable constant which is declared in the POU header.
Each group has a predefined color which can be changed by the user. Text, which does not belong to one of the above groups, is displayed in the editor text color which could be changed under View
씮 Color 씮 Text.
GX IEC Developer Reference Manual 3 – 47
The ST editor
3.14.2
The User Interface
Color setting for syntax colouring
The color settings are valid for the current GX IEC Developer 7.03 project only. They are available as new menu items under View
씮 Colors with the following menu item text:
– ST Keywords…
– ST Operators…
– ST Comments…
– ST Constant Numbers....
– ST Constant Strings…
– ST Global Variables…
– ST Local Variables…
Default foreground colors:
Keywords
Operators
Comments
Constant Numbers
Constant Strings
Global/Local Variables
(
(
(
(
RGB
(
(
0,
0,
0,
0,
0,
255,
0,
0,
128,
0,
0,
0,
255)
0)
0)
0)
0)
255)
Color
Tab. 3-15: Default foreground colors
If the menu item View
씮 System Defaults is chosen, all syntax colors, which have the same color as View
씮 Colors 씮 Text are changed to the Window setting for the foreground color of a window.
Options in structured text
By the help of a seperat dialogue the following options for the ST-editor can be configurated:
Auto Indentation
After pressing <RETURN> in the ST-editor (in edit mode), tabulators are automatically inserted at the beginning of the new line, if tabulators are existing at the beginning of the current line.
The number of tabulators is automatically increased, when it is expected (e.g. after keyword
FOR).
The number of tabulators is automatically decreased, when it is expected (e.g. after keyword
END_FOR).
This behaviour can be enabled or disabled in the options dialogue.
3 – 48
MITSUBISHI ELECTRIC
The User Interface The ST editor
Auto identifier proposal
If you enter an identifier, the system searches in the corresponding header of the POU for a variable or a variable constant which starts with the already entered characters. The compare is done case insensitive.
If only one identifier exists, it is automatically inserted and selected. The selected part can be overwritten or inserted by pressing <RETURN>. If you press <RETURN>, the cursor will be placed behind the inserted identifier.
If several identifiers are existing, a list of all identifiers is shown which match the already entered characters. You then can select one from the list or add additional characters.
If you confirm a suggested identifier with <RETURN> or select one from the list of identifiers the already entered characters are deleted and the selected identifier is inserted. Therefor it is possible to enter characters in any case and, after an identifier is selected, it is inserted as it is written in the POU header.
The auto identifier proposal can be enabled or disabled in the options dialogue.
ToolTip on a variable-identifier
Right mouse button
If the right mouse button is pressed, a context sensitive menu is shown.
Line number in the status bar
The current line number is shown in the status bar at the very left side in the format “Line: nnn” where nnn is the current line number. The first line has the line number 1.
This behaviour can be enabled or disabled in the options dialogue.
ST Options
An additional property is available to configure the following options:
Option
Auto indentation
Auto identifier proposal
Line number in the status bar
Tab size (1 - 64)
Default
ON
ON
ON
4
Tab. 3-16:
ST Options
See section 2.8.11 for the design of the dialogue.
See section 3.19 for the tool tip configuration.
Background color
The background color of the editor (in edit mode) is the same as for all editors. It can be changed with View
씮 Colors 씮 Background.
To make it obvious for the user, that the monitoring mode was activated, all colors of the syntax colouring groups are changed to the current text color when the monitoring mode is switched on.
GX IEC Developer Reference Manual 3 – 49
The ST editor
3.14.3
The User Interface
Monitor functionality in ST editor
There a three different monitoring possibilities in the ST editor.
ToolTip:
Monitor boolean values:
The monitoring of boolean values in the source code window is done like in the IL editor. This item is invoked by Online
씮 Start Monitoring 씮 Body.
A box is painted around a boolean variable or address in the monitor color. If the monitored value is ON the box background is set to the monitoring color, if it is OFF it is shown as the current background color of the editor.
Splitted body:
In addition to the monitoring of boolean values in the source window the ST body could be split into source code window (left part) and variables / values window (right part) with configurable border:
3 – 50
Fig. 3-34:
Split Window
This item is invoked by Online \ Start Monitoring \ Split Window.
Modify Variable
By a double click on a variable name or by pressing the shortcut Ctrl + F9 when the edit cursor is positioned in a variable name the value of the variable could be changed in the source code window or variables / value window like in IL with functionality ‘ Modify Variable Value’. The related menu item is Online
씮 Modify Variable Value.
By pressing the shortcut Alt + F9 on a boolean variable the value is toggled. The related menu item is Online
씮 Toggle Variable.
MITSUBISHI ELECTRIC
The User Interface The ST editor
Example
Show MELSEC Code Of Selection
In addition to the menu item ‘Show MELSEC Code Of Network’ the menu item ‘Show MELSEC
Code Of Selection’ is available. The MELSEC codes of the current selected lines are shown in an extra window similar to the ‘Show MELSEC Code Of Network’.
The header off the window will show the selected lines. For example:
(* TestST [PRG] *)
(* MELSEC code of TestST, line 4 - 11 *)
(* Code generated at 17.07.02 09:16:56, 7 steps *)
쑶
It is not possible in the editor to select independent lines. All statements are taken completely, even when only a part of a statement is selected.
Tracking
The tracking functionality is available in monitor mode.
Bookmarks
With the menu item Edit
씮 Toggle Bookmark (Ctrl F7) a bookmark could be set or reset.
With the menu item Edit
씮 Next Bookmark (F7) the cursor is positioned at the start of the line of the next bookmark. If the line is currently not visible it is scrolled into view.
With the menu item Edit
씮 Previous Bookmark (Shift F7) the cursor is positioned at the start of the line of the previous bookmark. If the line is currently not visible it is scrolled into view.
With the menu item Edit
씮 Delete all Bookmarks all bookmarks are deleted.
Bookmarks are saved to the project database (max. 100 items) when the body is saved. This allows the reuse of set bookmarks at the next edit session.
GX IEC Developer Reference Manual 3 – 51
The ST editor
3.14.4
The User Interface
Limitations
The possible data type for Mitsubishi K and H constants is calculated for all IEC editors depending on their device values:
Device Value
K-32768
K0
K32768
K-2147483648
H0
H10000
-
-
-
-
-
-
K-1
K32767
K2147483647
K-32769
HFFFF
HFFFF FFFF
IEC Data Type
INT | DINT
INT | WORD | DINT | DWORD
DINT | DWORD
DINT
INT | WORD | DINT | DWORD
DINT | DWORD
Tab. 3-17: Calculation of constants
Constant Value
-2147483648
-32768
0
32768
65536
2147483648
16#0
16#10000
-
-
-
-
-
-
-
-
-32769
-1
32767
65535
2147483647
4294967295
16#FFFF
16#FFFF FFFF
Tab. 3-18: Calculation of constant values
IEC Data Type
DINT
INT | DINT
INT | WORD | DINT | DWORD
DINT | WORD | DWORD
DINT | DWORD
DWORD
INT | WORD | DINT | DWORD
DINT | DWORD
As in former GX IEC Developer versions the Mitsubishi devices FX, FY and FD are not supported in GX IEC Developer 7.03. Indirect devices like @D0 can also not be used except in
MELSEC IL networks.
As in former GX IEC Developer versions for the following MELSEC instructions no
Manufacturer Library function are defined in GX IEC Developer 7.03:
LD LDI AND ANI
ORB NOP NOPLF PAGE
ECALLP EFCALL EFCALLP FCALL
OR ORI
CALL CALLP
FCALLP XCALL
ANB
ECALL
To start a timer in GX IEC Developer the functions TIMER_M or TIMER_H_M must be used instead of the MELSEC instructions OUT or OUTH with two operands.
3 – 52
MITSUBISHI ELECTRIC
The User Interface
3.14.5
The ST editor
Edit functions
How to activate editing mode
There are two ways to activate editing mode:
쎲 By double-clicking in the editing area, or
쎲 By clicking on the Edit Network tool:
Edit Network tool
The entry cursor is then displayed in the editing area.
How to change the column width
햲 In select mode, position the mouse pointer on the vertical line between the columns.
The pointer changes to a double-headed arrow.
햳 Hold down the left mouse button and drag the dividing line to the left or right as required.
Or:
Hold down the
´ key and move the dividing line left or right with the ¥ and ¤ cursor keys.
When you release the mouse button or the
´ key the dividing line is redisplayed in the new position.
How to enter comments
햲 Position the cursor at the point where you wish to enter the comment.
You can insert comments anywhere in the Instruction List, i.e. in the third column or in a new line.
햳 Comment text must always be enclosed by the characters (* and *).
How to insert a programming instruction and a variable
GX IEC Developer Reference Manual 3 – 53
The graphical editors
3.15
The User Interface
The graphical editors
Operation of the two graphical editors – Ladder Diagram and Function Block Diagram – is comparable to working in a standard graphics program. The program elements used for writing
PLC programs are provided in the toolbar and the Tools menu.
� � �
�
�
�
�
�
�
쐅
NOTES
쐉 쐈
Fig. 3-35:
Programs in graphical editor
Item
�
쐅
쐈
�
�
�
쐉
쐃
쐇
�
�
�
Description
Ladder Diagram (LD)
Function Block Diagram (FBD)
Network bar
Editing area
Input variable (poll for signal status ‘1’)
Input variable (negated, poll for signal status ‘0’)
Function
Output variable
Output coil (Ladder Diagram only)
Comment
Input contact (poll for signal status ‘1’) (Ladder Diagram only)
Power bar (Ladder Diagram only)
Tab. 3-19: Graphical editor items
See the chapter 6 for details on programming.
A detailed description on how to insert programming instructions and variables is given at the end of this chapter.
All key combinations for working in graphical editors are described in the Appendix B.
3 – 54
MITSUBISHI ELECTRIC
The User Interface
3.15.1
The graphical editors
Options
In the menu Extras - Options you can specify options which make handling operations in the graphic editors easier.
Fig. 3-36:
Extras - Options
FBD/LD
Declare New Identifiers: When you overwrite a dummy variable in a graphical editor with a variable identifier name that has not yet been declared the Variable Selection (Mode
NewVar) dialogue box will be displayed automatically so that you can enter the declaration for the new variable.
Pin Overwrite: When you create a connection to an empty variable connection in a graphical editor the empty variable will be overwritten.
Automatic Input/Output Variables: The system will automatically create the input and output variables when you insert a function block in a graphical editor.
Automatic ENO Variables: The system will automatically create the ENO output variable when you insert a function block in a graphical editor. If the ENO output variable is not needed this option has to be disabled.
GX IEC Developer Reference Manual 3 – 55
The graphical editors
3.15.2
The User Interface
Context menu
When edit mode is active you can display the context menu by clicking the right mouse button or pressing
.
Fig. 3-37:
Editor context menu
3.15.3
Line / Arrow (toggle function): Toggles between select mode and interconnect mode.
AutoConnect: Makes positioning and moving graphical elements simpler. When elements are moved the connection lines are redrawn automatically (
Mouse Pointer Purpose
Select Mode
Interconnect Mode
Select Mode + AutoConnect
Interconnect Mode + AutoConnect
Tab. 3-20: Editor mouse pointers
VarInput Pin: Insert input variable (same as Tools - Input Variable)
Contact (LD only): Insert input contact (same as Tools - Contact)
VarOutput Pin: Insert output variable (same as Tools - Output Variable)
Coil (LD only): Insert output coil (same as Tools - Coil)
FUN/FB: Opens Function Block Selection dialogue box for programming instruction selection
Last 5 function blocks list: The last 5 function blocks inserted in the LD or FBD editors can be reused directly by selecting them from the list at the bottom of the context menu.
Right mouse button or F2
Mouse pointer in editing mode / on block: Activates context menu
Mouse pointer on variable: Opens the Variable Selection dialogue box for selection of a variable from the list.
Mouse pointer on a jump instruction: Opens the Label List dialogue box for selection of a network label from the list.
3 – 56
MITSUBISHI ELECTRIC
The User Interface
3.15.4
The graphical editors
Program Elements
Tool Program element
Lines (Interconnect Mode)
Input contact
(Ladder Diagram only)
Input contact negation
(Ladder Diagram only)
Input L-contact
(Ladder Diagram only)
Input L-contact negation
(Ladder Diagram only)
Vertical line
(Ladder Diagram only)
Horizontal line
(Ladder Diagram only)
Output coil
(Ladder Diagram only)
Function block
(programming instruction)
Input variable
Output variable
Tab. 3-21: Program elements
Menu Command
Tools - Network Elements -
Interconnect Mode
Tools - Network Elements -
Contact
Tools - Network Elements -
Contact Negation
Tools - Network Elements -
L-Connection Contact
Tools - Network Elements -
L-Connection Contact Negation
Tools - Network Elements -
Vertical Line Segment
Tools - Network Elements -
Horizontal Line Segment
Tools - Network Elements -
Coil
Tools - Network Elements -
Function block
Tools - Network Elements -
Input Variable
Tools - Network Elements -
Output Variable
7
8
5
6
9
0
3
4
1
2
Key(s)
§T
How to insert new program elements
Icons are provided in the toolbar for all the available program elements.
햲 Click on the tool for the element you wish to insert.
Or:
Select the menu command from the Tools menu, or press the corresponding key combination.
The mouse pointer then changes to the symbol for the selected program element.
햳 Position the tip of the pointer at the point where you want to insert the element and press the left mouse button or the
« key.
How to select program elements
햲 Click on the program element.
Or:
Position the pointer over the program element with the cursor keys and then press the
´ key.
Selected program elements are highlighted in a different color.
GX IEC Developer Reference Manual 3 – 57
The graphical editors The User Interface
NOTE
How to select more than one program element
쎲 Selecting elements out of sequence: Hold down the ¨ key and click on all the program elements you wish to select.
Selecting elements in sequence: Position the mouse pointer outside the area to be selected, hold down the left mouse button and drag the dotted rectangle around the elements you wish to select.
Or:
쎲 Selecting elements out of sequence: While holding down the ¨ key, select the elements one after another by positioning the mouse pointer over them with the cursor keys and pressing
´.
Selecting elements in sequence: Position the pointer outside the area to be marked. While holding down the
´ key, use the cursor keys to drag the dotted rectangle around the program elements you wish to select.
Selected program elements are highlighted in a different color.
You can only select multiple program elements within the same network.
How to increase and decrease editing area spacing
The Tools - Open Row/Open Column commands are used to increase and decrease the horizontal and vertical spacing in the editing area.
햲 Select the menu command or the corresponding tool in the toolbar.
The pointer changes to a horizontal or vertical double-headed arrow.
햳 Position the pointer at the location where you wish to increase/decrease spacing.
햴 Increase spacing: Click with the mouse button or press the ´ key.
Decrease spacing: Hold down the
¨ key while clicking or pressing the ´ key.
How to enter comments
You can enter comments at any point in the editing area.
햲 Select Comment in the Tools menu or the corresponding tool in the toolbar.
The pointer changes to a comment text symbol.
햳 Move the pointer to the position where you wish to insert the comment.
햴 Hold down the left mouse button and drag to create a comment field.
Or:
Hold down the
´ key and create a comment field with the cursor keys ¤ and ¢.
When you release the mouse button or the
´ key the blinking editing cursor appears in the newly-created comment field.
햵 Enter your comment text.
How to insert a programming instruction
3 – 58
MITSUBISHI ELECTRIC
The User Interface
3.15.5
The graphical editors
AutoConnect
The AutoConnect function can be activated in the Tools menu or the context menu.
The AutoConnect mode makes moving and connecting graphical elements much easier.
When you move the elements the connecting lines are stretched and rerouted automatically, so that you do not need to edit the lines by hand. To connect elements in the AutoConnect mode you simply click on the start and end points and the lines are drawn automatically.
The mouse pointer has the following forms in AutoConnect mode:
Mouse Pointer Purpose
Select Mode + AutoConnect
Interconnect Mode + AutoConnect
Tab. 3-22: Editor mouse pointers
Moving elements (rubber banding)
햲 Activate both select mode and AutoConnect.
햳 Click on the element you wish to move and drag it to the new position, holding the left mouse button down.
햴 Release the mouse button when you reach the position at which you wish to place the element.
Fig. 3-38:
The lower block MOV_M and its associated connecting lines are selected.
Fig. 3-39:
The block is dragged to its new position. Temporary diagonal connection lines are displayed while you are repositioning the block.
Fig. 3-40:
The block has been moved to its new position and the connecting lines have been redrawn automatically. The variables have also been moved automatically, thus retaining their positions relative to the function block.
GX IEC Developer Reference Manual 3 – 59
The graphical editors The User Interface
If there is an anchor point on the connection line the lines will only be modified up to the position of the first anchor point. The lines on the other side of the anchor point and the anchor point itself all remain unchanged.
An error message will be displayed if you try to move an element to a position that GX IEC
Developer cannot calculate. You can then abort the move operation.
The Undo function is available as well.
Inserting connection lines (autorouting)
햲 Activate both Interconnect mode and AutoConnect.
햳 Click on the position for the starting point. Possible starting points are indicated by black dots. This activates the connecting line, which follows the mouse pointer as you move it.
Fig. 3-41:
AutoConnect starting point
햴 Position the mouse pointer at the end point.
Fig. 3-42:
AutoConnect end point
햵 Click on the end point.
The connecting line is drawn automatically.
Fig. 3-43:
"AutoConnected" line
3 – 60
MITSUBISHI ELECTRIC
The User Interface The graphical editors
Recalculate Line
The menu command Recalculate Line in the Tools menu helps to recalculate lines which have already been drawn.
In the normal Interconnect Mode (AutoConnect is disabled) a connection with several lines has been created.
Fig. 3-44:
Connecting line before recalculation
햲 Activate the Interconnect Mode and AutoConnect.
햳 Click on the connection.
All lines of the connection will be marked.
햴 Activate the command Recalculate Line in the Tools menu.
The connection is recalculated.
Fig. 3-45:
Recalculated connecting line
Possible starting and end points
Try moving the connecting line over the various elements in the editing window. As you do so black dots are displayed to indicate possible connection points. The connecting line is drawn to the black dot under the tip of the pencil symbol when you click the mouse button.
Examples of possible connection points:
– Variable connections (without variables) on function blocks
– Between variables and variable connections (without variables) on function blocks
– Ends of lines
– Positions on lines
Fig. 3-46:
Starting and end points
The positions of the connection points are dictated by the grid raster.
If you click on a position where no black connection dots are displayed the operation will be aborted automatically, thus preventing the inadvertent creation of connection lines without connected ends.
GX IEC Developer Reference Manual 3 – 61
The graphical editors The User Interface
Anchor points
Double-clicking on a potential connection point creates an anchor point. Anchor points are indicated by small black squares.
When you move elements in the editing window the positions of the anchor points remain unchanged.
Fig. 3-47:
Anchor point
NOTES
Overwriting unassigned variable pins
If the starting or end point of a new line is an unassigned variable connection (pin) the connection is overwritten automatically when the line is inserted. You can activate or deactivate this function with the Extras - Options - Editing - Pin Overwrite option.
Restrictions for connecting lines
Do not try to insert connecting lines between variable pins for which different variable types have been declared. This will result in an error message when you perform a check on the
POU.
Do not try to draw connecting lines through function blocks.
3 – 62
MITSUBISHI ELECTRIC
The User Interface
3.15.6
The graphical editors
Variables
How to configure input signals
Double-click on an input contact or on the connection of the input variable in a function block.
Or:
Position the pointer with the cursor keys on an input contact or on the connection of the input variable in a function block and press the key combination [CTRL]+[ALT]+[S].
A dialogue box is displayed with the following options:
Normal
Poll for signal status ‘1’
Negation
Poll for signal status ‘0’
Make the appropriate selection in the dialogue box.
�
Fig. 3-48:
Input signal configurations:
Normal and negated
�
� �
Item
쐃
쐇
�
�
Description
Negated input variable
Normal input variable
Normal input contact
Negated input contact
Tab. 3-23: Signal configurations items
An input signal can also be configured directly:
햲 Click on the input contact or a function block to select it.
햳 Press the key combination [CTRL]+[ALT]+[S] to negate the input or press the key combination [CTRL]+[ALT]+[C] to undo the negation.
Or:
햲 Click on the input contact or a function block to select it.
햳 In the menu Edit select Toggle Signal Configuration and click on the selected input.
The signal configuration of this input will be toggle.
If you select Edit - Signal Configuration, after clicking on the selected input the
Signal Configuration dialogue appears.
GX IEC Developer Reference Manual 3 – 63
The graphical editors The User Interface
How to configure output signals
햲 Double-click on an output coil or on the connection of the output variable in a function block.
Or:
Position the pointer with the cursor keys on an output coil or on the connection of the output variable in a function block and press the key combination [CTRL]+[ALT]+[S].
A dialogue box is displayed with the following options:
Normal
Poll for signal status ‘1’
Negation
Set
Reset
Poll for signal status ‘0’
Set (output coil only)
Reset (output coil only)
Make the appropriate selection in the dialogue box.
�
�
Fig. 3-49:
Output signal configurations:
Normal and negated
�
�
� �
Item
쐃
쐇
�
�
�
�
Description
Normal output coil
Negated output coil
Set output coil
Reset output coil
Normal output variable
Negated output variable
Tab. 3-24: Signal configurations items
How to assign input and output variables to programming instructions
햲 Select Tools - Input Variable/Output Variable or the corresponding tool in the toolbar.
The pointer changes to an input variable or output variable symbol.
햳 Position the tip of the pointer over the connection of the function block.
햴 Click on this position.
Or:
Press the
´ key.
The variable is inserted. You must now assign the variable name.
3 – 64
MITSUBISHI ELECTRIC
The User Interface The graphical editors
NOTE
�
Most programming instructions have a specific number of input variables. However, in some cases (e.g. ADD_E) the number of input variables can be increased. With these instructions the Number of Pins field is activated in the programming instruction dialogue box. Enter the required number (max. 28) in this field. Note that the EN input is not included in the total. For example, if you enter 5 connections for the ADD_E function the resulting Block will have 5 real connections for the addition operation and one EN input.
Fig. 3-50:
ADD_E function
�
Item
쐃
쐇
Description
One EN input
Five addition connections
Tab. 3-25: Items of programming instructions
How to insert a variable
Þ page 3-62
Adding and removing input variables
햲 Select a function block for which the number of input variables can be changed.
There are variety of different ways to add/remove input variable pins:
쎲 Increment Pins / Decrement Pins options in the Edit menu
쎲 + and - keys in the numeric keypad
쎲 Toolbar icons:
Increment
Decrement
쎲 Position the mouse pointer on the lower border of the function block. When the pointer changes to a double arrow press the left button and drag down (increment) or up
(decrement).
Incrementing
If the Automatic Input/Output Box option in Extras - Options - Editing is activated empty dummy variables are automatically inserted when you increment the number of variable pins.
Decrementing
The input variables will be deleted if they are still empty, i.e. if no variable has yet been assigned to them. However, if variables have already been assigned to them they will not be deleted.
GX IEC Developer Reference Manual 3 – 65
The graphical editors The User Interface
How to insert input and output variables in the graphical editors automatically
햲 Activate the Automatic Input/Output Box option in Extras - Options - Editing.
When this option is activated the input and output variables are automatically inserted when you add a function block in the graphical editors. The dummy identifier ?
(question mark) is inserted in the variable name field.
Fig. 3-51:
Function block
NOTE
Deleting variables
햲 Select the variable’s connecting line.
햳 Press µ.
Or
햲 Select the question mark dummy or the variable name.
햳 Press µ.
햴 Press the © key.
You do not need to delete the variables at the connecting pins before inserting lines in
AutoConnect mode. They are overwritten automatically.
Stepping through variables in a network
Pressing
© and ¨© steps through all the variables in the current network forwards or backwards, selecting them one after another.
3 – 66
MITSUBISHI ELECTRIC
The User Interface The graphical editors
3.15.7
NOTE
NOTE
Jump and Return Instructions
How to configure jump instructions (label and signal)
A jump instruction executes a branch to a specified network, using the network label as the destination.
햲 Click on the dummy label by the jump instruction symbol.
Or:
Position the pointer over the dummy label and press the
´ key.
햳 Enter the jump destination name.
햴 Double-click on the jump instruction symbol.
Or:
Position the pointer over the jump instruction symbol and press the
« key.
A dialogue box is displayed with the following options:
Normal
Negation
Poll for signal status ‘1’
Poll for signal status ‘0’
햵 Make the appropriate selection in the dialogue box.
The jump instruction corresponds to the JMP operator in the Instruction List.
Operator (IL) Program element (LD/FBD)
JMP
JMPN
Normal jump (poll for signal status ‘1’)
Negated jump (poll for signal status ‘0’)
JMPC
JMPCN
Normal jump with input condition
Negated jump with input condition
How to configure return instructions (signals)
The return instruction returns control from a function block to the program from which the function block instance was called.
햲 Double-click on the return instruction symbol.
Or:
Position the pointer over the return instruction symbol and press the
« key.
A dialogue box is displayed with the following options:
NormalPoll for signal status ‘1’
NegationPoll for signal status ‘0’
햳 Make the appropriate selection in the dialogue box.
The return instruction corresponds to the RET operator in Instruction List language (IL).
Operator (IL) Program element (LD/FBD)
RET
RETN
Normal return instruction (Poll for signal status ‘1’)
Negated return instruction (Poll for signal status ‘0’)
RETC
RETCN
Normal return instruction with input condition
Negated return instruction with input condition
GX IEC Developer Reference Manual 3 – 67
The graphical editors
3.15.8
The User Interface
Graphic macros
Setting the number of graphic macros
You can create and store up to 25 graphic macros.
Number of Graphic macros in Extras - Options - Graphic
Enter the number of graphic macros you wish to use.
How to create graphic macros
햲 Select the area in the editing area that you wish to store as a graphic macro.
The selected area is highlighted.
햳 Select the Copy command in the Edit menu.
The selected area is copied to the clipboard.
햴 Select Define Graphic Macros in the Tools menu.
The Configure Custom Tools dialogue box appears on the screen.
햵 Select the name under which you wish to store the macro.
If a macro is already stored under the selected name its contents are shown in the
Contents box.
햶 Click on the Paste button.
The contents of the clipboard are pasted into the Contents box.
햷 Click on the Close button to confirm your entries and close the dialogue box.
Fig. 3-52:
Creating graphic macros
Selecting graphic macros
Tools - Custom: The names of the first five graphic macros are displayed in the menu and they can also be selected by pressing
¦ together with the corresponding number key.
Tools - More Custom: Enables you to select all available graphic macros.
3 – 68
MITSUBISHI ELECTRIC
The User Interface
3.16
Selecting Programming Instructions
Selecting Programming Instructions
Graphical editors:
쎲 Menu: Tools - Network Elements - Function Block
쎲 Toolbar icon
쎲 FUN/FB context menu (right mouse key)
Text editors:
쎲 Menu: Tools - List Operators/Operands
쎲 key
쎲 Right mouse key
The Function Block Selection dialogue box is displayed. It remains open, active and visible until it is explicitly closed. It is also closed automatically when you close the current body or activate another window on the screen.
Fig. 3-53:
Function Block Selection
Libraries
: All programming instructions available for the PLC currently selected.
<Project>: Functions and function blocks created by the user (depends on the selection in the
Operator_Type field)
Manufacturer_Lib: All programming instructions in the manufacturer library
Standard_Lib: All programming instructions in the standard library
Last recently used
All recently-used programming instructions
GX IEC Developer Reference Manual 3 – 69
Selecting Programming Instructions The User Interface
Operator Type
All Types: IEC operators, functions and function blocks
Operators: IEC operators
Functions: Functions
Function Blocks: Function blocks
Number of Pins
This field is activated when the instruction allows you to change the number of input contacts
(input pins).
Operators
All available programming instructions (depends on the selections in the previous fields). If you enter the first letters of an instruction manually the highlight automatically jumps to the first instruction beginning with that letter or letter combination.
APPLY button
Graphical editors: When you move the mouse pointer over the editing window it changes to a pointer with a function block symbol. Simply click at the position where you wish to insert the instruction.
Text editors: Enters the selected programming instruction in the editor window.
Getting help on specific programming instructions
Select the instruction in the Operators list field and then press the Help button.
3 – 70
MITSUBISHI ELECTRIC
The User Interface
3.17
3.17.1
Variables
Variables
Selecting existing variables and declaring new variables
Before you open the Variable Selection dialogue box:
Graphical editors: Highlight the variable/instance dummy name
Text editors: Place the cursor in the variables column
Sequential function chart language: Highlight a transition definition
Then:
In the Task Information dialogue box: Event (F2 key only)
In both graphical and text editors:
- Tools - List Operators/Operands menu
-
key
- Right mouse button
The Variable Selection dialogue box is then displayed. This dialogue remains open and visible on the screen and does not need to be closed when you perform other editing actions in the program body. If you prefer to minimize the dialogue box automatically after applying a declaration, activate the “Minimize Dialogue after apply” checkbox.
Fig. 3-54:
Variable Selection
Scope
All of the project’s variables:
<Header>: All local variables in the header of the currently open POU
<Global Vars>: All global variables
Manufacturer_Lib: Reserved for functions to be added later
Standard_Lib: Reserved for functions to be added later
GX IEC Developer Reference Manual 3 – 71
Variables The User Interface
NOTE
Type
Depends on the selections in the Libraries and Type Class list fields:
Simple Types: Simple data types: ANY, ANY_BIT …
Data Unit Types: Structured data types (DUT)
Function Blocks: Function blocks
For existing variables the currently valid type is displayed.
Default settings:
- Graphic editor: Data type of formal parameter, contact/coil: BOOL
- Transition in SFC: BOOL
The variable selection dialogue includes a variable type filter.
The type list only includes variable types valid for the actual project and does not include variable types that are not available for the used PLC type.
Type Class
Simple Types: Simple data types
Data Unit Types: Structured data types (DUT)
Function Blocks: Function blocks
For existing variables the currently valid type class is displayed.
Fig. 3-55:
Selecting a variable
Type Class: Simple Types
Type: BOOL
Variables: The variables are displayed.
Doubleclick on the variable to select it.
3 – 72
Variables
Depends on the selections in the preceding list fields: All existing variables
When you enter the first letters of the variable name the highlight will automatically jump to the first variable with this letter or letter combination.
APPLY button
Enters the selected variable into the selected variable dummy name in the editor (same effect as double-clicking).
MITSUBISHI ELECTRIC
The User Interface Variables
NEW ON button
Selecting this button expands the dialogue box, displaying an additional area for the declaration of new variables. The dialogue box title changes to Variable Selection (Mode
NewVar).
Fig. 3-56:
Variable Selection in new variable mode
This dialogue box also appears:
쎲 When you select the Tools - New Variable menu option (ALT + N).
쎲 When you overwrite a dummy variable name in a graphical editor with the name of a var iable that has not yet been declared. This automatic function can be activated/deactivated with the option Extras - Options - Editing - Declare New
Identifiers.
Fig. 3-57:
Dummy variable name
The expanded dialogue box fields enable you to declare new variables of the type defined by the selections in the Library, Type and Type Class fields. The entries are the same as those in the variable declaration tables.
You can also declare instances, in the same way as in the declaration tables.
DEFINE or UPDATE button
Selecting this button confirms and accepts all your entries for the new or existing variable. The button is inactive (greyed out) if your entries are incorrect or incomplete.
The new variable or the changes on a existing variable are automatically added to the corresponding declaration table.
NEW OFF button
Shrinks the dialogue box back to its original size, hiding the new variable declaration fields again.
GX IEC Developer Reference Manual 3 – 73
Variables The User Interface
IEC 61131-3
This field displays all the available IEC information for the selected variable.
3.17.2
NOTE
Find unused variables
By using the function Extras Find Unused Variables you can find and delete all unused global and local variables that are declared but not used in a project. Unused global and local variables will be detected in the whole project, excluding the user libraries.
Finding unused variables can only be performed if the project has been built and was not changed since then. Otherwise a warning message will be displayed.
If the compiled code exists and is up to date, the project will be checked. When there are unused variables in the project, the following dialogue will be displayed. It shows the name, location and – optionally – additional information about the variables. By using this dialogue you can remove the declaration of selected variables, or of all of them.
Fig. 3-58:
Find unused variables
3 – 74
Each unused variable is listed under the container of its declaration: the Global Variable List for global variables, or the corresponding POU for local variables. Only those containers are listed where unused variables exist. For example, if there is no unused global variable, the Global
Variable List location will not be enlisted. Containers are written in bold text and appear at a higher level than their contained items.
MITSUBISHI ELECTRIC
The User Interface Variables
Variables in containers to which no read-access is granted at the current security level are not enlisted. Variables in containers to which no write-access is granted at the current security level are displayed in a disabled state. These variables cannot be selected for deletion.
It is possible that a function (FUN) or function block (FB) POU has an unused variable with the type VAR_INPUT, VAR_OUTPUT or VAR_INOUT. These kinds of variables serve as the interface of the POU. Although an unused interface variable can be deleted, this deletion changes the interface of the POU, and all callers of this POU have to be revised. For this reason, when at least one interface variable is selected for deletion, the following confirmation message will be displayed:
Fig. 3-59:
Warning message
The progress of the deletion will be indicated in the left side of the status bar.
If all unused variables have been deleted, the dialogue (Fig. 3-58) will be closed. Otherwise the
dialogue will be kept displayed showing the updated list of unused variables.
GX IEC Developer Reference Manual 3 – 75
Search and Replace
3.18
The User Interface
Search and Replace
A new functionality to replace an object in Ladder and FBD is available.
If an operator, a function or a function block is marked in editors of the type LD and FBD and if you select a new operator, function or function block (e.g. from the dialogue Function Block
Selection or from the pick list with the last recently used objects), the marked object is replaced by the new object.
Example
Fig. 3-60:
Before the operation
After the operation:
Fig. 3-61:
After the operation
쑶
No additional input or output boxes are inserted (regardless of whether the option Automatic
Input/Output Variables is enabled) and the already available connections to the replaced operator, function or function block are automatically connected to the new one.
3 – 76
MITSUBISHI ELECTRIC
The User Interface Search and Replace
If the height of the new object is greater than the old one, the functionality Open Row is automatically applied to the lower border of the old object, before the new object is inserted. If the width of the new object is greater than the old one, the functionality Open Column is automatically applied to the right border of the old object, before the new object is inserted.
Example
Fig. 3-62:
Before the operation
After the operation:
Fig. 3-63:
After the operation
쑶
If the size of the new object is equal or smaller than the old one, no change in the layout is done.
GX IEC Developer Reference Manual 3 – 77
Search and Replace The User Interface
The functionality to replace an object in Ladder and FBD is added to the search and replace functionality, so that a manual replace functionality (Button Replace) and an automatic replace functionality (Button Replace All) is available:
Fig. 3-64:
Dialogue Replace
If the autoconnect mode is switched off, it will be switched on automatically in the background during the operation.
If the name in the field Replace With is no valid operator, function or function block, the search and replace operation will be aborted.
3 – 78
MITSUBISHI ELECTRIC
The User Interface
3.19
Tooltips
Tooltips
Tooltips, which are provided for body editors of the type LD, FBD, ST, IL and MELSEC IL, support the user during the programming and monitor activity.
If the user moves the mouse cursor over a variable, a Tooltip will appear after a short moment:
Fig. 3-65:
Appearance of ToolTips
The provided information in the displayed Tooltip can be configured in the options dialogue
(see section ). The following items are available:
쎲 Monitored value (is only shown in monitor mode)
쎲 Class
쎲 Mitsubishi address
쎲 IEC address
쎲 Type
쎲 Initial value
쎲 Comment
쎲 Remark
(only the first 80 characters are shown)
(only the first 80 characters are shown)
An additional setting switches between single line (all items are separated by semicolons in one line) and multi line (each item is displayed in a separate line).
GX IEC Developer Reference Manual 3 – 79
Tooltips The User Interface
3 – 80
MITSUBISHI ELECTRIC
Projects and Objects
4 Projects and Objects
Projects
4.1
Projects
The project is the object at the top of the hierarchical structure used in GX IEC Developer. In
IEC 61131-3 terms, a project is comparable with a resource. In GX IEC Developer it corresponds to one PLC system.
A project consists of considerably more than just one file. When you create a new project, GX
IEC Developer creates a separate subdirectory with the name of the project. All the files used by the project are always stored in this directory.
4.1.1
NOTE
The automatically-generated project files
쎲 *.PRO: Project (all objects except libraries)
쎲 *.BAK: Backup of the file *.PRO
쎲 *.SAV: Extra backup copy of the file *.BAK generated when a restore is performed
(
쎲 PLCDOKU: ASCII PLC configuration files when printing (PLC_Parameter)
쎲 WORKSPACE.SYS: Workspace settings (View - Save Workspace)
쎲 CUSTOM.SYS: Graphic Macros (Tools - Custom)
쎲 LRUBOXES.SYS: All the programming instructions used in the project (Last recently
Used list box in the Function Block Selection dialogue box in the graphical editors)
쎲 SFC.OBJ: Last program organisation unit created in the Sequential Function Chart language (temporary file stored in a special format)
During the compilation and data transfer processes GX IEC Developer generates a number
of temporary files that should not be edited or tampered with in any way. See the Appendix D
for details.
GX IEC Developer Reference Manual 4 – 1
What are the components of a project?
4.1.2
Projects and Objects
Files with standard extensions
쎲 *.ASC
쎲 *.EDM
쎲 *.SED
쎲 *.PRN
쎲 *.XLS
쎲 *.SUL
쎲 *.SCT
쎲 *.SCX
Import/Export File
Entry Data Monitor Settings
Setup for Entry Data Monitor
Print File
Excel File for Device Editor
User Library
Files for the Cross Reference data base
Automatic link of the SCT files to the SCX file when generating the cross reference data base
4.2
What are the components of a project?
Projects consist of Objects. The following are all objects in GX IEC Developer:
쎲 The libraries in the Library_Pool
쎲 The PLC parameters
쎲 The tasks in the Task_Pool
쎲 The data unit types in the DUT_Pool
쎲 The global variables
쎲 The program organisation units in the POU_Pool, consisting of headers and bodies
These objects are displayed in the Project Navigator window, which is automatically displayed when you open a project. The project name is displayed as the first entry in this window.
The Project Navigator window is the ‘control centre’ or ‘starting point’ for all operations performed on these objects. The relationships between the original objects are reflected in the hierarchical structure of the Project Navigator tree.
4 – 2
MITSUBISHI ELECTRIC
Projects and Objects
4.3
The Project Navigator and Objects
The Project Navigator and Objects
Fig. 4-1:
The Project Navigator window
In the Navigator three different views can be selected via tabs: Project, Calltree, and Used by.
For details refer to section 3.4.1.
Fig. 4-2:
The Project Navigator window for a Remote I/O project
4.3.1
Q Remote I/O projects have only parameter data. The Navigator shows only the parameter node and its sub-nodes.
Furthermore, the project navigator window has only the project view, because the Call Tree and Used By views are not applicable for Q Remote I/O projects, as they have no program (and therefore neither libraries, tasks, GVLs nor POUs).
Library Pool
The following libraries contain the programming instructions:
쎲 Standard Library
쎲 Manufacturer Library
쎲 User Library
For more information on the library concept see page 4-8.
GX IEC Developer Reference Manual 4 – 3
The Project Navigator and Objects Projects and Objects
4.3.2
NOTE
4.3.3
Parameter
In the dialogue box PLC parameter you set and store the following PLC system parameters:
쎲 Memory parameters
쎲 Latch operand range
쎲 Timers and Counters range
쎲 I/O configuration
쎲 Network link settings
쎲 PLC setup data
쎲 Special parameters
쎲 System variables
쎲 PLC CPU type selection
See chapter 5 for details on configuring your system.
Task Pool
Within a project, the task is the highest level in the hierarchy. The task contains the executable program organisation units, which are the subprograms that go to make up a project. Tasks can be either event-triggered or executed at preset intervals. Tasks are also assigned priorities, which determine the execution hierarchy when tasks are executed under the same conditions.
4.3.4
4.3.5
DUT Pool
Data unit types are structured data types consisting of collections of variables that can be of different data types. Data unit types must be declared as global variables.
Values can be assigned to the individual elements (variables) of the data unit type in the body of the POU (
A DUT can also be used as return type for a function. An ARRAY of DUT is not allowed as function result if it is copied to another ARRAY of DUT. But it is possible when the function result is assigned to the parameter of a FB macro.
If the same function is used twice as input parameter of e.g. a FB macro, a temporary variable would be necessary because the second function call would overwrite the values of the first function call. This is not supported for:
쎲 A DUT as function result.
쎲 An ARRAY of DUT as function result.
Global Variables
Global variables are declared for the entire project. They make it possible to exchange data between all the individual subprograms that make up the project (
4 – 4
MITSUBISHI ELECTRIC
Projects and Objects
4.3.6
The Project Navigator and Objects
POU Pool
The sorting criteria for the listing of the POUs in the POU pool can be toggled. Three different sorting criteria are available:
쎲 By name (alphabetically)
쎲 By type
쎲 By programming language (alphabetically)
Right-click on the POU pool to open the context menu and select Sorting Criteria. The Sort
Criteria Precedence dialogue will be opened. In this dialogue you can specify the precedence of each sorting criteria via the Up and Down buttons.
Fig. 4-3:
Sort Criteria Precedence
All program organisation units (POUs) consist of a header and a body.
쎲 Header
: The header contains the declarations of the
Local Variables used in the POU.
쎲 Body
: The body contains the actual PLC program code of the POU.
The entries after the POU name specify the Class:
쎲 [PRG]
쎲 [FB]
쎲 [FUN:INT]
:
:
: Program
Function Block
Function
The entry before the POU name specifies the compilation:
쎲 *
: The asterisk indicates that this POU has not been compiled.
The entries after ‘Body’ specify the programming language in which the PLC program in the body is written:
쎲 [IL]
쎲 [LD]
쎲 [FBD]
쎲 [SFC]
쎲 [MELSEC IL]
쎲 [ST]
쎲 Action_Pool (SFC only) :
:
:
:
:
:
:
Instruction List
Ladder Diagram
Function Block Diagram
Sequential Function Chart
MELSEC Instruction List
Structured Text
All the POU’s Actions
GX IEC Developer Reference Manual 4 – 5
The Program Organisation Unit (POU) Projects and Objects
4.4
NOTE
The Program Organisation Unit (POU)
The ‘actual’ PLC program code is stored in the body of each POU. However, this no longer consists of just one PLC program with its own subroutines. In GX IEC Developer you use groups of subprograms – the program organisation units. These self-contained subprograms are administrated by tasks; together, they make up the complete PLC program.
A program organisation unit always consists of a header and a body. The header contains the variables, which are only available within this POU. The body contains the executable PLC program code.
An introduction to the IEC 61131-3 standard and the basic principles of this new programming concept is provided in the Beginner’s Manual in the chapter ‘The IEC 61131-3
Standard’. For tips on writing PLC sequential control programs in the various programming
languages (editors), please refer to chapter 6 in this Reference Manual.
4 – 6
MITSUBISHI ELECTRIC
Projects and Objects Preparation Before You Start Programming
4.5
NOTE
Preparation Before You Start Programming
Structured programming …
To work really effectively with GX IEC Developer it is very important to analyse and plan the task to be programmed in as much detail as possible before you actually begin to write the code. Divide the entire machine process into small sub-processes, and treat each sub-process as an independent unit. Implement each of these sub-processes as a Program
Organisation Unit.
… and program management
Develop a sequential structure showing how the individual sub-processes are to be executed.
The program organisation units are called via Tasks (triggered either by events or at defined intervals).
Global Variables
Draw up a list of your Global Variables, i.e. the variables whose hardware addresses must be known, and which must be available to all the components of the program (e.g. inputs, outputs, operands for possible later visual display of the process or operator guidance, analog inputs, etc). The global variables should be declared before you start developing the program so that each sub-program can access them. Of course, you can also add to the list in the course of program development, if necessary.
Reusable subroutines
Program frequently-used processes as Functions or Function Blocks. The functions and function blocks are stored in a library and can be used at any point in the project where they are needed.
To be able to call a function block you must create an ‘instance’ of it, in a process known as
‘instancing’ or ‘instantiation’ (
Data Unit Types
Create Data Unit Types for parts of the process where the same constellations of variables must be accessed again and again. The creation of data unit types corresponds to the instantiation of function blocks (
Graphical or textual based programming
The best editor type to use for your project, graphical or textual, depends on the type and scope of the programming task. As a rule of thumb, Ladder Diagram and Function Block
Diagram are best for most applications because of their simple entry options and clear representation of the program. These graphical editors make programming functions and function blocks particularly simple. The Instruction List language allows more flexible programming, but it also requires knowledge of the underlying syntax, for example for calling functions and function blocks or for programming Arrays. The Sequential Function Chart and the Struc-
tured Text languages are special cases; strictly speaking, they actually are no programming languages at all, but rather structuring tools. It makes it very easy to see and follow the program sequence. Individual logical sections of the program (sub-processes) can be programmed as macros (
GX IEC Developer Reference Manual 4 – 7
Library Concept Projects and Objects
4.6
NOTE
NOTE
NOTE
Library Concept
A distinction is made between the following three types of library:
쎲 Standard Library
쎲 Manufacturer Library
쎲 User Library
Standard Library
The Standard Library is for information purposes only. It contains the following elements:
쎲 DUT_Pool
쎲 Global_Vars
쎲 POU_Pool
:
: Irrelevant for programming purposes
Irrelevant for programming purposes
: The POU_Pool contains the standard IEC programming instructions supported in GX IEC Developer. You can view the variable declarations in the header, but you cannot edit them.
The SLIB.LIB contains the contents of the Standard Library in packed format.
Manufacturer Library
The Manufacturer Library is also for information purposes only. It contains the following elements:
쎲 DUT_Pool
쎲 Global_Vars
쎲 POU_Pool
:
: Irrelevant for programming purposes
Irrelevant for programming purposes
: The POU_Pool contains all the ‘Adapted’ MELSEC programming instructions with nomenclature modified for the
IEC editors (
Þ ‘Programming Instructions’ in Appendix E).
You can view the variable declarations in the header but you cannot edit them.
The file MLIB.LIB contains the contents of the Manufacturer Library in packed format.
User Libraries
A user library gives you the possibility of creating functions and program segments which can be used on a supra-project basis. The program segments are grouped in a library and can be used in any project. Following updating, changes made to the library can be applied to other projects.
A user library can contain all the objects that are also available in a project: Global Variables
List, Data Unit Types, Arrays and Program Organisation Units. You can assign a password to protect the know-how in the library.
The name of the user library file has the file extension SUL.
The MMP703.INI initialisation file contains the LIBRARIES section, where you can make directory settings (
4 – 8
MITSUBISHI ELECTRIC
Projects and Objects Library Concept
How to create a new user library
햲 Select the Install/Create User Library command in the Edit menu.
The following dialogue window is displayed:
Fig. 4-4:
Install/Create User Library
햳 Click on the Browse Lib. button. The Select Library Path dialogue window appears.
햴 Choose the directory in which the library is to be stored.
햵 Enter a new name for the library.
햶 Confirm with OK.
The entries are transferred to the Install/Create User Library dialogue window, where they can also be changed.
햷 Confirm the library entries with OK.
The new library appears in the Navigator, along with the Standard Library and the
Manufacturer Library.
The Install/Create User Library dialogue window
Library Path: Directory in which the library file is to be created. This can be any directory, although it is sensible to choose a central directory for the User Libraries.
Library Name: Descriptive name for the library, max. 32 characters.
Help Path: Directory and file name for the Help file. A separate Help file can be created for each User Library.
Browse LRU...: A window is opened which displays the most recently used User Libraries.
You can select a library from this window.
Browse Lib...: A window is opened for you to select a directory and enter a library file. A User
Library is given the file extension SUL.
Browse Help...: A window is opened for you to select a directory and enter a Help file. A Help file is given the file extension HLP.
View Help: The Help file is opened.
GX IEC Developer Reference Manual 4 – 9
Library Concept Projects and Objects
NOTES
How to protect the User Library with a password
햲 Select the desired User Library in the Navigator.
햳 Select the User Library - Change Password command in the Edit menu.
This opens a dialogue window containing the following items:
Old Password: When changing an existing password, the old password must first be entered here. If you are assigning a password for the first time, you must skip this field by pressing
[ENTER].
New Password: Entry of the new password.
Confirmation: Repeat entry of the new password.
Access rights
Allow read access for closed library: If this option is checked, the body for all POUs of the corresponding user library is shown in the navigator and the body can be opened in read-only mode.
A protected User Library can only be opened and edited if the password is known. As long as the
User Library is closed and the password is not known, it is impossible to make any unauthorised changes. Only the header of the POU can be viewed, the body cannot be opened.
If the option Allow read access for closed library is activated, the body (and the header) for all POUs of the corresponding user library is shown in the navigator and the body can be opened in read-only mode:
- from the navigator
- from the header of the POU
- from other POU bodies (with a function or a function block of this user library)
- from the browser window
- from the dialogue ‘Compile/Check Messages’
- from the system error dialogue
Remove/Delete User Library
Remove: The Remove User Library command removes the User Library selected in the
Navigator from the project. The library must be open at the time. The file is not deleted by this operation.
Delete: The Delete User Library command physically deletes the User Library selected in the
Navigator, along with the associated library file.
Update User Library
Every User Library can be used and modified in various projects. If, however, a change is made in Project_1, this change is not available in Project_2 until the Update Libraries command has been executed in the Edit menu.
E
WARNING:
It may, however, also be advisable not to update the library in a particular project.
Consequently, you should always take a look at the associated Help texts of the libraries before performing an update!
4 – 10
MITSUBISHI ELECTRIC
Projects and Objects Library Concept
Browse for User Libraries
If User Libraries which are not found in the specified path are accessed (e.g. open User
Library, export project), the Userlib not found dialogue opens where you can browse for them. From this dialogue you can also create new User Libraries and save the information from the project to them.
This function does not depend on the current status of the User Libraries (opened, closed, changed, not changed, password, no password).
Under the following conditions a new User Library has to be created:
햲 When opening the User Library (transition from installed to opened status)
햳 When saving the user-library (transition from changed to opened status)
햴 When exporting a project with user-libraries (no transition)
If such a condition is recognised, a dialogue is opened where you either can:
햲 Create a new User Library at the original place
햳 Browse for the User Library
햴 Create the User Library at any proper place
햵 Cancel the new creation of the User Library
Check for new library versions when opening a project
When opening a project with libraries, an automatic check for new available versions is executed. If a new version is found, the library and the corresponding file are listed in the following dialogue:
Fig. 4-5:
Library update check
When updating the selected libraries, opened libraries are closed and for changed libraries you will be asked to save.
Updated libraries are removed from this list.
GX IEC Developer Reference Manual 4 – 11
Working with Projects
4.7
Projects and Objects
Working with Projects
How to Create a New Project
햲 Select New in the Project menu. The dialogue box Select PLC Type is displayed.
Fig. 4-6:
At this point,
CPU Type
selection is the only active field.
햳 Select the CPU for which you are programming from the list box.
햴 Confirm your selection with OK.
The dialogue box New Project is displayed.
햵 Select a directory for your project or type in the path in the Project Path field. If you wish, you can also enter a directory that does not yet exist; GX IEC Developer will then create it for you automatically.
햶 Enter the name of the project at the end of the project path.
Fig. 4-7:
The project name can be a maximum of 255 characters long (Microsoft Windows standard for long file names).
The project name does not need an extension as it refers to a directory and not a file.
NOTE
햷 Click on the Create button.
The program displays the Wizard dialogue box.
햸 Select the required project option and confirm with OK.
The program will then create the project database on the disk.
In case of creating a new project for a FX CPU a warning comes up, that warns you of existing limitations concerning the Online Program Change function for the FX series (
씮
8.7.3). So you should avoid making changes in the program that cannot be carried out by
online program change, if you want to use this function later on.
4 – 12
MITSUBISHI ELECTRIC
Projects and Objects Working with Projects
The project creation process is documented in an information box (loading the programming instructions from the libraries, opening the project).
When it generates a new project GX IEC Developer doesn’t create a single file but a subdirectory with the project name. This subdirectory contains all the files that make up the project.
The two libraries – the Standard Library and the Manufacturer Library – are always loaded with every new project that is created. When you begin, they are displayed in the Project Navigator window with the various pools, which are still ‘empty’.
The Wizard
The Wizard is a special tool. When the new project has been generated the following dialogue appears.
Fig. 4-8:
Wizard for new projects
NOTE
NOTE
The project wizard will not show up when creating a Q Remote I/O project, because the project does not have any program.
Select the desired startup option for your project:
Ladder Diagram: Creates a simple project consisting of one task and optionally a Sub task.
Each task contains one Ladder Diagram POU (Program Organisation Unit).
MELSEC IL: Creates a simple project consisting of one task and optionally a Sub task. Each task contains one MELSEC IL (MELSEC Instruction List) POU. You enter the MELSEC mode.
Only the programming language MELSEC IL is available in the project. IEC POUs can not be added.
Project Structure: Starts the interactive Project Structure Builder Assistant. You are guided through several steps, creating tasks and POUs depending on your selections,
Empty Project: Does not use any assistance. Creates an empty project containing no tasks or
POUs.
If you do not wish to use the Wizard’s support you can deactivate it by editing the Wizard setting in the MMP703.INI file (
GX IEC Developer Reference Manual 4 – 13
Working with Projects Projects and Objects
NOTE
How to open an existing project
햲 Select Open in the Project menu, or click on the corresponding tool in the Toolbar.
Tool for opening an existing project
The Open Project dialogue box is displayed.
햳 Select the drive, the directory and the project name.
햴 Click on the Open button.
Fig. 4-9:
Projects are easy to identify in the directory list – their path symbols are displayed in yellow.
If the project was not stored properly because of a power failure or because it was not closed correctly a ‘cracked’ yellow path symbol is displayed next to the project name. Usually, such projects can be restored.
Please note that you can only open and edit one project, in one Project Navigator window.
But you can start GX IEC Developer several times to open and edit more than one project at a time.
How to recover a project
GX IEC Developer has a facility for recovering projects that were not closed properly because of a power failure or some other problem. These projects are identified by a ”cracked” directory path symbol in the Open Project dialogue box.
햲 Click on the ”cracked” directory symbol.
A dialogue box is displayed with three options: Recover, Use Backup and Cancel
Recover: This option restores all the project’s data so that nothing is lost. The system restores the exact editing status of the project at the point the unplanned termination happened.
Use Backup: Loads the status of the project as it was the last time you loaded it for editing. All changes made between then and the unplanned termination are lost. An additional backup copy of the project is generated and stored in the file *.SAV.
Cancel: Cancels the procedure and closes the dialogue box.
햳 Click on the appropriate button.
4 – 14
MITSUBISHI ELECTRIC
Projects and Objects Working with Projects
NOTES
When you create a new project the files *.PRO and *.BAK are created automatically. All editing changes and entries you make are stored in the PRO file.
When you open an existing project that was closed correctly GX IEC Developer loads *.PRO
and creates *.BAK. Here too, all the entries and editing changes you make are stored in the
PRO file. The BAK file stores the status of the project at the point it was loaded.
As you can imagine, when you select Recover, the system loads the PRO file in which all the editing changes up to the termination point are stored.
By the same token, selecting Use Backup loads the BAK file. This means that if you first created the project in the editing session in which the termination occurred the BAK file will be empty!!! If you loaded an existing project in the last editing session the BAK file contains the status of the project from the point when you began the editing session. Whenever a
*.BAK file is loaded an automatic additional backup copy of the project is generated and stored in the file *.SAV.
How to open the SAV file
햲 Open the File Manager.
햳 Create a new directory.
햴 Copy the SAV file into this new directory.
햵 Rename the file *.SAV into *.PRO.
햶 Open this PRO file in GX IEC Developer.
How to close a project
햲 Select Close in the Project menu.
Or:
Close the Project Navigator window with the Close command in its control menu (key combination
§), or by double-clicking on the control menu button.
A prompt will be displayed asking you if you wish to save the project. If object windows (e.g.
headers or bodies) with unsaved editing changes are open a separate prompt will be displayed for each window.
How to Save a Project
햲 Saving your project with the current name: Select Save in the Project menu, or click on the corresponding tool in the Toolbar.
Tool for saving the current project
Saving under a new project name: Select Save As in the Project menu. Select the desired subdirectory and assign a new project name.
When you save the project the backup file is updated automatically.
GX IEC Developer Reference Manual 4 – 15
Working with Projects Projects and Objects
NOTE
NOTE
NOTE
How to delete a project
햲 In the Project menu open the Other submenu and select Delete.
The Delete Project dialogue box is displayed.
햳 Select the drive, directory and project name.
GX IEC Developer projects are identified by a yellow path symbol next to the directory name.
햴 Click on the Delete button.
You cannot delete a project while it is open!
How to rename a project
햲 In the Project menu open the Other submenu and select Rename.
The Rename Project dialogue box is displayed.
햳 Select the drive, directory and project name.
GX IEC Developer projects are identified by a yellow path symbol next to the directory name.
햴 Enter the new project name in the New Project Name field.
The project name can have a maximum of 8 characters. You can also enter the name of a directory that does not yet exist, and GX IEC Developer will create it for you automatically.
햵 Click on the Rename button.
You cannot rename a project while it is open.
How to copy a project
햲 In the Project menu open the Other submenu and select Copy.
The Copy Project dialogue box is displayed, with two list boxes.
햳 Select the drive, directory and name of the project to be copied in the left list box.
GX IEC Developer projects are identified by a yellow path symbol next to the directory name.
햴 Creating a copy with the same name: Simply select the target drive and directory in the list box on the right. Creating a copy with a new name: Select the target drive and directory in the right hand list box, and then enter a new name at the end of the path. The new project name can have a maximum of 8 characters. You can also enter the name of a directory that does not yet exist; GX IEC Developer will then create it for you automatically. Overwriting an existing project with a copy: Select an existing project in the right hand list box.
햵 Click on the Copy button.
You cannot copy or overwrite a project while it is open. Please also have a look at the functions provided by the Import and Export commands in the Project - Other menu (
4 – 16
MITSUBISHI ELECTRIC
Projects and Objects Working with Projects
How to back up a project
The command Extras - Backup Project packs the project files and stores them to a medium on the selected drive. External data media such as floppy disks are supported. If the resulting project file is larger than the capacity of the disks it is automatically split across the necessary number of disks.
햲 Select Backup Project in the Extras menu. The following dialogue box is displayed.
Fig. 4-10:
Project backup dialogue
NOTES
햳 Select the format for the backup operation:
Packed project database: File format *.PCD: The complete database (already compiled) and the libraries will be packed.
Packed export format: File format: *.PCE: The project data (without compilation, without libraries) will be exported and packed. When restoring a PCE file you have to compile the project again.
햴 Select the target drive and directory, then enter a name for the target file.
햵 Click on the OK button to pack the project and copy it to the selected drive.
햶 If the target drive is a floppy disk drive you will be prompted to insert the first disk. If the packed file is too large to fit on the disk it will be automatically split across the necessary number of disks. You will be prompted to change disks when necessary.
The Backup Project command can only be executed for the project currently opened.
With the Export function in the Project - Other menu the project data are exported into an
ASCII file only, without being compiled or split across the necessary number of disks.
GX IEC Developer Reference Manual 4 – 17
Working with Projects Projects and Objects
How to restore a project
The command Extras - Restore Project is used to restore a backed up project from a packed file. After being unpacked the project is automatically opened.
햲 In the Extras menu select Project Restore.
The following dialogue box is displayed.
Fig. 4-11:
Restore project dialogue
NOTE
햳 In the upper line select the PCD or PCE file which you wish to unpack and open.
햴 In the lower line select the target drive and directory and enter a name for the target project.
햵 Click on the OK button to unpack and open the project.
The name for the target project is not a file, but a directory.
How to reorganize a project database
The command Tools - Reorganize Database... is used to reorganize a project database. This function fixes possible defragmentation problems in GX IEC Developer 32-bit *.pro project files and repairs damaged database records. The menu item is available only if no project is opened.
햲 Select Tools - Reorganize Database....
A standard file open dialogue is displayed.
햳 Select the desired *.pro file to be reorganized and click on the Open button.
The project file is reorganized while the progress status is indicated.
4 – 18
MITSUBISHI ELECTRIC
Projects and Objects Working with Objects
4.8
NOTE
NOTE
Working with Objects
How to open objects
햲 Double-click on the object in the Project Navigator window.
Or:
Select the object in the Navigator and then click on Open in the Object menu.
The window or dialogue box of the selected object will then be opened.
There are two possible responses when you double-click on a POU name, depending on the settings in the MMP703.INI file and in the menu Extras - Options - Zoom Header/Body -
Navigator Zoom (
- Show/hide header and body in the Project Navigator window
- Open Header and body
How to close objects
햲 Close the object window.
햳 Before the operation is executed a prompt will be displayed asking you if you wish to save any editing changes. Click on Yes if you wish to save the changes.
The various different ways of closing windows are explained in chapter 3.
How to create new objects
햲 In the Toolbar, select the tool for the object you wish to create.
Or:
Select New in the Object menu, then select the desired object type from the pop-up list displayed (POU, DUT, Task or Action).
햳 Make the necessary entries in the dialogue box. Enter the name of the object. In the case of program organisation units you must also specify the POU’s class (Program,
Function Block or Function) and the programming language. In the case of actions you must select the programming language.
The newly-created object is displayed in the Project Navigator window. You can now open the object to edit it, if necessary.
How to save objects
햲 Select the window of the object you wish to save.
햳 Select Save in the Object menu.
Or:
Press the following key combination:
Save
§S
GX IEC Developer Reference Manual 4 – 19
Working with Objects Projects and Objects
NOTE
NOTE
NOTE
How to rename objects
햲 Select the object to be renamed in the Project Navigator window.
햳 Select Rename in the Object menu.
햴 Enter the new name in the dialogue box.
The new name of the object will then be displayed in the Project Navigator window.
You can only rename closed objects.
How to cut, copy or delete objects
햲 In the Project Navigator window, select the object that you wish to cut, copy or delete.
햳 Select the appropriate command in the Edit menu.
Or:
Press the corresponding key combination:
Cut
Copy
Delete
§X
§C
µ
The Cut operation deletes the data from its original position and stores it in the clipboard.
The Copy operation copies the data to the clipboard without changing it in its original location.
The Delete operation deletes the data from its present location without copying it to the
clipboard. This means that any data that was in the clipboard prior to the delete operation remains unchanged.
Objects can only be deleted if the corresponding object windows are closed (e.g. header
and body in the case of POUs)
How to paste objects
햲 Activate the Project Navigator window.
햳 Select Paste in the Edit menu.
Or:
Press the following key combination:
Paste
§V
Please note that the system does not prompt you for a new name before inserting the data.
Objects in the clipboard are inserted in the new location with their original names. You must then rename the new objects manually with Edit - Rename, and it may also be necessary to perform editing to eliminate double variable declarations (in the case of POUs).
The Copy and Paste functions can also be used to copy and paste objects between projects, not just within the current project.
4 – 20
MITSUBISHI ELECTRIC
Projects and Objects Working with Objects
NOTE
NOTE
How to copy objects from the current project to another project
햲 Select the object or objects to be copied in the Project Navigator window.
햳 Select Copy in the Edit menu.
Or:
Press the following key combination:
Copy
§C
A copy of the data is now in the clipboard.
햴 Close the current project, then open the project into which you wish to copy the objects.
햵 Activate the Project Navigator window.
햶 Select Paste in the Edit menu.
Or:
Press the following key combination:
Paste
§V
The data from the clipboard are inserted in the Project Navigator window.
You can also exchange objects between projects with the Import and Export functions
(Project - Other - Export/Import).
How to enter comments
햲 In the Project Navigator window, select the object for which you wish to enter a comment.
Or:
Activate the object window.
햳 Select Comment in the Object menu.
햴 Type your comment text in the left field.
How to copy, cut and paste comments
햲 Select the text to copy or cut.
You can use the standard Windows mouse operations and key combinations for selecting text.
햳 Click on the Cut, Copy or Paste button.
You can also use the standard Windows key combinations for these operations:
Cut
Copy
Paste
§x
§C
§v
GX IEC Developer Reference Manual 4 – 21
Working with Objects Projects and Objects
How to view the object information
햲 In the Project Navigator window, select the object whose information you wish to view.
Or:
Activate the corresponding object window.
햳 Select Information in the Object menu.
Or:
Press the key combination
¦«.
A dialogue box is opened showing attributes of the selected object.
General Options
Fig. 4-12:
Name: Name of the selected object
Size: Size of the selected object in bytes
Type: Type of the selected object
Last Change:
Data and time of the last editing change
Security Level: Current security level
Read Access:
Read access for lower security levels
Comment: Comment text
Additional Options for Body Objects
Fig. 4-13:
Language: Programming language
E
WARNING:
The system will allow you to change the programming language of a POU, but if you do this you will lose all the codes in the body! A message will be displayed.
4 – 22
MITSUBISHI ELECTRIC
Projects and Objects
Additional Options for Functions
Working with Objects
Fig. 4-14:
Result Type: Result data type
(displayed when you change the program class)
Use with EN/ENO: If you change the program class to Function this field allows you to specify whether the function is to have a Boolean input and output.
Type: Program class
Language: Programming language used in the body
Additional options for Function Blocks
Fig. 4-15:
Macrocode: Macrocode execution of the function block (
Þ
page 6-61)
MC-MCR: MC-MCR execution of the function block (
Þ
page 6-61)
Use with EN/ENO: If you change the program class to FB (Function Block) this field allows you to specify whether the function block is to have a Boolean input and output.
Type: Program class
Language: Programming language used in the body
GX IEC Developer Reference Manual 4 – 23
Working with Objects Projects and Objects
NOTE
Additional Options for Task Objects
Task attributes can only be set in this dialogue box.
Fig. 4-16:
Event: Event-triggered
Interval: Interval-triggered
Priority: Priority level of the task
Timer/Output Control: MC-MCR execution of the task (
Þ
page 6-2 )
How to display an object’s Call Tree (subordinate objects)
햲 Select the object whose Call Tree you wish to display.
햳 In the Object menu, select Show and then select Call Tree from the submenu displayed.
An information box is opened showing all the objects used in the selected object.
쎲 Task Call Tree: All associated POUs and all the global variables used in the POUs
쎲 POU, Body and Header Call Trees: All function block instances and all global variables
How to display an object’s Reference List (superordinate objects)
햲 Select the object whose Reference List you wish to display.
햳 In the Object menu, select Show and then select Reference List from the submenu displayed.
An information box is opened showing all the objects in which the selected object is used.
쎲 Function Block Reference List: The headers in which the instances of the function block were generated
쎲 POU Reference List: The associated task
4 – 24
MITSUBISHI ELECTRIC
Projects and Objects
4.9
4.9.1
Protecting Your Data
Protecting Your Data
Project security
GX IEC Developer has a eight-level data security system. You can assign a different password to each level, and you can assign security levels to both the entire project and each individual object within the project. The security level assigned to any object will be inherited to all its child objects provided their security level is not higher.
For example, if you assign a security level of 5 to the project you can edit all objects with security levels 0 through five. Objects with security levels 6 and 7 are not editable, but you can view their contents. The names of protected objects are displayed in grey in the Project
Navigator window. POUs that are both read and write protected also do not allow you to branch into their headers and bodies in the Project Navigator window.
How to assign security level passwords
햲 Select Change Passwords in the Project menu.
햳 Select the security level to which you wish to assign a password.
햴 Enter the current password in the Old Password field. If you have not yet entered a password for this level, simply leave this field empty.
햵 Enter the new password in the New Password field.
Fig. 4-17:
As an additional security measure asterisks are displayed on the screen instead of the characters you enter.
햶 Confirm your entry by re-entering the same new password in the Re-enter Password field.
햷 Click on the Change button to enter the password.
A message will be displayed telling you whether the system has accepted the old and new passwords.
How to change the project’s security level
햲 Select Change Security Level in the Project menu.
햳 Select the desired security level.
햴 Enter the valid password for this security level in the Password field.
An error message will be displayed if you enter the password incorrectly.
GX IEC Developer Reference Manual 4 – 25
Protecting Your Data Projects and Objects
How to assign read and write protection to objects
햲 Select the object to be protected in the Project Navigator window.
햳 Select Information in the Object menu.
Or:
Press the key combination
¦«.
Fig. 4-18:
The Object Information dialogue box is displayed.
NOTE
햴 Click on the desired security level.
햵 Write protection: Click on a security level higher than the current level in order to protect the object against unauthorised editing.
햶 Read protection: Deactivate the Allow Read Access For Lower Levels check box to prevent read access to the object.
If the project has security level 5 and the object has already been assigned security level 6 you cannot change the security level of the object in this dialogue box. Security levels that cannot be selected are displayed in light grey. To change the security level of such objects you must first change the level of the project; for instance, in this example, you would have to change the project security level to 6. This is only possible if you know the password of this security level, of course. Action: Check and enter PLC keyword for access to the PLC CPU.
4 – 26
MITSUBISHI ELECTRIC
Projects and Objects Protecting Your Data
NOTE
How to protect the PLC program
Access to the PLC CPU can be restricted by entering a PLC keyword to prevent unauthorised persons from transferring programs from the CPU.
The user is prompted to enter the password once before every Online operation. The password is also checked internally before execution of every subsequent Online operation.
In case of QnPRH PLCs in Backup mode the user is asked if he wants to set or delete the keyword for both PLCs. You will be asked to enter the keyword for the Control system first.
GX IEC Developer will attempt to use the same keyword for the Standby system as well.
If it fails, you will be asked to enter the keyword for the Standby system as well.
If different keywords are used for the control and the standby system, both keywords will be stored and automatically used for any further operations.
햲 In the Online menu select the PLC keyword command, then select Current, New or
Delete.
햳 Enter the appropriate PLC keywords in the corresponding fields. You can move from field to field with the [TAB] key. For security, all the characters you enter are displayed as asterisks on the screen.
Fig. 4-19:
Entering a new PLC keyword
Fig. 4-20:
Entering a new PLC keyword for a FX3U PLC
1st and 2nd keyword/Protection level (only FX3U)
If the PLC is protected with two keywords, it is possible to modify the protection level without changing the keywords. If both of the old keywords are entered correctly, and neither new keyword is specified, the protection level will be changed to the selected setting, and the keywords will be kept.
The Protection level selection group will be enabled only if both new keywords are specified or both old keywords are specified and neither or both new keywords are specified.
GX IEC Developer Reference Manual 4 – 27
Protecting Your Data Projects and Objects
Old keyword: Enter the old keyword (8 characters from range 0 to 9 and A to F).
New keyword: Enter the new keyword (8 characters from range 0 to 9 and A to F).
Verify: Enter the new keyword once again(8 characters from range 0 to 9 and A to F).
햴 Confirm your entries with OK.
Meaning of the different commands under the submenu PLC keyword
Current: Enter current PLC keyword for access to the Online functions.
New: If an old PLC keyword has already been entered you must first enter it for confirmation.
Then enter the new PLC keyword in the next field, after which you must enter it again for confirmation in the last field.
Delete: Delete the current PLC keyword for the PLC CPU.
Disable Protection (only FX3U): You will be offered to specify the first or both keywords in the
PLC Keyword dialogue.
Fig. 4-21:
Entering one or both PLC keywords for a FX3U PLC
If only the first keyword is specified, the validity of the keyword will not be verified directly. It will be checked when the first attempt is made to access protected data. In that case, if the currently specified keyword is wrong, it will be asked again.
If both keywords are specified, the validity of the keywords will be verified directly. In case the keywords are incorrect, they will be asked again. In case the keywords are correct, the protection of the PLC will be immediately disabled. A warning will be given that the protection will be enabled again only when it is explicitly enabled or the PLC is reset.
Enable Protection (only FX3U): By calling this menu command the disabled keyword protection can be re-enabled. The following success message will be displayed after performing the operation.
Fig. 4-22:
Enabling Protection
4 – 28
MITSUBISHI ELECTRIC
Projects and Objects Protecting Your Data
When the project is about to be closed, and all of the following conditions are met, you will be warned that the PLC is likely to be in an unprotected state, and you will be offered to re-protect the PLC:
쎲 the PLC is protected with two keywords
쎲 keyword protection was disabled at least once while the project was open
쎲 keyword protection was not re-enabled after the last disablement by:
– calling the menu item Online
PLC Keyword Enable Protection
– registering new keywords
Fig. 4-23:
Warning that the PLC is likely to be in an unprotected state
4.9.2
NOTES
NOTE
Protected Symbolic Information
The symbolic project information of a project for the A/QnA/Q series cannot be protected by the PLC keyword. Using the function of password protection for symbolic information enables the user to prevent access to these data by unauthorized users.
The use of password protection for symbolic data increases the time to download/upload of the symbolic information by 30–35 % on an average configuration.
Symbolic information download to a FX PLC is not supported by GX IEC Developer.
When downloading symbolic information to the PLC, the user is asked to enter a password that will be required later to upload the symbolic information from the PLC again. This password may be the same as the PLC keyword, but there is no correspondence between those two passwords. Changing the PLC keyword does not effect the symbolic information password, and vice versa.
The set password even is not related to the project (it is not stored in the project file), it is only related to the symbolic information on the PLC.
Only the read access is password protected. Symbolic information can still be deleted or overwritten on the PLC without a password, since the PLC keyword does not protect those actions. This protection can only be achieved by hardware protection. Of course the symbolic information files can be read from the PLC as well, but they have no meaning to a user not knowing the password and the encryption algorithm.
Symbolic information can be downloaded by the following functionalities:
쎲 Download project (Þ section 8.6.8)
쎲 Online change (Þ section 8.7.3)
쎲 Download symbolic information to PLC (Þ section 8.6.2)
GX IEC Developer Reference Manual 4 – 29
Protecting Your Data Projects and Objects
When using any of the three functionalities, the user is asked to enter a password.
Fig. 4-24:
Symbolic Information Password
Password: Entry of the new password.
Re-type password: Repeat entry of the new password.
Use this password while this project is open: Select this option to activate the entered password for the time the project is opened.
The user may choose to use the entered password during the project is open, i.e. the password will not be asked for every download until another project is opened.
This remembrance possibility suppresses the password dialogue for every download or online change, so users that download changes to their projects frequently will not have to enter the password every time during one session.
When uploading symbolic information, the password is always asked for.
It is still possible to download symbolic information without protection. If the user does not enter a password, a warning will be displayed to confirm that the user really does not want to protect the symbolic data.
Fig. 4-25:
Warning
4 – 30
There is the option to disable this warning for the rest of the GX IEC Developer session. In that case an empty password will be accepted without requestion.
When uploading protected symbolic information from the PLC, the password has to be entered by the user.
Fig. 4-26:
Dialogbox to query the required password
MITSUBISHI ELECTRIC
Projects and Objects Protecting Your Data
NOTE
If the correct password is entered, the symbolic information will be uploaded. Otherwise symbolic upload cannot be executed and binary upload will be offered instead.
If the PLC’s program is protected by keyword (PLC keyword) and this keyword has not been input since the project was opened, the user will be prompted to enter the PLC keyword
(standard operation for binary upload) (
The protection of the symbolic information files results in changed file formats, which older
GX IEC Developer versions cannot handle. The file format of unprotected symbolic information is the same as in older versions.
The following message will be displayed in an older GX IEC Developer version if attempting to upload protected symbolic information:
Fig. 4-27:
System Message
Improved Import/Export security
In case a project contains protected POUs and the user wants to make a symbolic download of the project, the following mechanisms are applied.
The dialogue contains two edit fields for entering the passwords, and the two entered passwords have to match to be accepted. Otherwise the user is asked to enter them again.
Normally, when exporting project elements to a file or the clipboard, the objects with a higher security level than the actual state are not included in the export stream and no warning will be given to the user. This behaviour does not break security, but it may lead to misunderstandings.
But symbolic information download (which is based on export) would export every needed object, including the ones the user has no access to. This behaviour clearly would break security. A person not having access to some objects could download symbolic project information to a PLC, and then upload it to a new project, making the formerly protected objects accessible.
For this reason file and clipboard export are working as follows:
쎲 If the actual security level is lower than the needed security level to export every object, a warning will be displayed to inform the user about this issue. The user will be asked if he wants to change the security level.
Fig. 4-28:
Security level warning
GX IEC Developer Reference Manual 4 – 31
Protecting Your Data Projects and Objects
쎲 When the user chooses Yes, the following dialogue will be shown to change the security level.
Fig. 4-29:
Change Security Level
NOTE
쎲 If the user chooses No in the message box shown in Fig.4-28, the inaccessible objects will not be exported.
쎲 Choosing Cancel in in the message box shown in Fig. 4-28, the process using the export functionality will be cancelled.
If the user decides to change the security level, but then cancels the Change Security Level dialogue or sets a security level still not high enough to export every object, the message box shown in Fig. 4- will be displayed again, until the needed security level is set or No is chosen in this message box.
Drag & drop will not display the question message box, because it is a “silent” operation.
Showing a message box after starting to drag would interrupt the drag & drop process and the drop could not be executed. Export in this case is based on the actual security level.
4 – 32
MITSUBISHI ELECTRIC
Projects and Objects Printing Out Project Data
4.10
NOTE
Printing Out Project Data
How to configure the printer
햲 Select Printer Setup in the Project menu. This opens the Windows Print Setup dialogue box showing the current default printer and its parameters. The changes and settings you can make in this dialogue box depend on the printer connected to your computer.
For full details, consult the Windows User’s Guide and your printer manual.
How to print an object
햲 Select any object in the Project Navigator or open the window of the object to be printed.
햳 Select Print Preview in the Object menu to open the print preview display. The display gives you quite a precise preview of what the printout will look like. If the printout includes more than one page, you can navigate through the pages via the Page buttons. You can Zoom In (increase) or Zoom Out (decrease) the view size via the
Zoom buttons. You can cancel printing by clicking the Close button.
햴 Click the Print button.
Or:
Press the key combination
¦p.
The Print dialogue box is displayed.
햵 Select the appropriate print options.
Selecting the Setup button opens the Print Setup dialogue box, in which you can set the parameters of the default printer or select another printer.
햶 Start the printout with the OK button.
If you do not need to preview the printout, you can directly print any selected or opened object.
In the Object menu select Print.
How to print project data
햲 Select Print Preview in the Project menu to open the print preview display. The display gives you quite a precise preview of what the printout will look like. If the printout includes more than one page, you can navigate through the pages via the Page buttons. You can Zoom In (increase) or Zoom Out (decrease) the view size via the
Zoom buttons. You can cancel printing by clicking the Close button.
햳 Click the Print button.
Or:
Press the key combination
¦p.
The Print dialogue box is displayed.
햴 Select the appropriate print options.
Selecting the Setup button opens the Print Setup dialogue box, in which you can set the parameters of the default printer or select another printer.
햵 Start the printout with the OK button.
If you do not need to preview the printout, you can directly print any selected or opened object.
In the Project menu select Print.
GX IEC Developer Reference Manual 4 – 33
Printing Out Project Data
4.10.1
Projects and Objects
Print options for project data
The content and layout of the project data printout can be customised extensively. Different print options settings can be saved as profiles. In the Project menu select Print Options to open the Print Options dialogue.
Fig. 4-30:
Print Options
4 – 34
Dialogue items
Object: Select whether only the current Project Tree or the currently Selected Items according to the current profile are printed.
Current Profile: Type or select (from the combo box) the name of the profile that you want to load, save, set as default, or delete.
Loaded Profile: Displays the currently loaded profile. If this field remains blank, the loaded profile was changed and not yet saved.
Default Profile: Displays the default profile for every printout. The default profile can be specified via the Set Default button.
Watch: Indicates whether any property setting of the loaded profile was changed, but the current profile is not saved. In this case the Loaded Profile field remains blank.
Save: If any property setting of the loaded profile was changed, this button becomes active.
Click the Save button to save the current profile under the name entered in the Current Profile box.
Delete: Deletes the profile entered in the Current Profile box. If the currently entered profile does not exist, an error message is returned.
Set Default: Sets the profile entered in the Current Profile box to the default profile. If the currently entered profile does not exist, an error message is returned.
Load: Loads the profile entered in the Current Profile box. The loaded profile is indicated in the Loaded Profile box.
Properties...: Opens the Document Configuration dialogue where you can change the property settings of the loaded profile (for details see below). If any property setting of the loaded profile was changed, this button becomes active and the Loaded Profile box is cleared.
List...: Opens the Checked Properties List where the specified property settings are summarized in a list.
Document Configuration
In the Document Configuration dialogue all property settings of the loaded profile for the project data printout can be specified.
MITSUBISHI ELECTRIC
Projects and Objects Printing Out Project Data
How to open the Document Configuration dialogue:
햲 In the Project menu select Print Options.... to open the Print Options dialogue.
햳 In the Print Options dialogue click on the Properties... button.
The Document Configuration dialogue opens:
Fig. 4-31:
Document Configuration for printouts
The Document Configuration dialogue includes the following property sheet tabs:
Scope
Selects the object class to be documented. This configured scope is related primarily with the selected objects in the main view.
The following objects can be selected for the printout:
쎲 Cover Page
쎲 Table of Contents
쎲 Project Tree
쎲 Cross Reference
POUs (FBD, IL/MELSEC IL, LD, SFC, ST): If FBD, IL, SFC and/or LD are checked, only the selected objects of this type will be documented.
The scope defined by each selection may be restricted through the detailed configuration of the items. The items may be configured via the other tabs.
Global Variable List: Check the option Print Global Variable List to print the Global Variable
List.
When you choose the option Print Global Variable List for printing or previewing of Array of
DUT variables, only basic informations about the addresses of the array members are shown:
쎲 WORD start address – address of first array element’s first non-Boolean member
쎲 WORD offset – address difference between two array elements’ WORD start addresses
쎲 Bit designation – whether to store Boolean members mapped onto non-Boolean devices
쎲 BIT start address – address of first array element’s first Boolean member
쎲 BIT offset – address difference between two array elements’ BIT start addresses
GX IEC Developer Reference Manual 4 – 35
Printing Out Project Data Projects and Objects
Additionally checking the print option Expand array of DUT addresses provides the possibility to print the addresses of every member of an Array of DUT variable.
By default the option is turned off, because the listing of all the addresses will make the list very long.
Cross Reference
The following objects can be selected for the printout:
쎲 Call Tree
쎲 Global Variables
The following selections are possible if Global Variables is selected: a) Used Read/Write variables (the cross reference for used read/write variables can be documented either for variable names or all addresses or a user-specified address range).
b) External declarations
General/Project Tree
The following options can be selected for the printout:
쎲 General: Zoom condensed or normal
쎲 Project Tree: Actual State or Expanded
쎲 LD and FBD: Not separated input/output pin directly connected.
If activated: After the calculation of the layout in FBD and LD an additional calculation will determine all functions and function blocks which have formal input or output pins (only input or output elements directly connected). This option avoids a page break within the function and ensures that the input or output will print the function and function block with their input or output elements on the next page.
Frame Logos
You can specify several bitmap graphics files (*.bmp) and a title for the printout appearing on every page in the header and footer:
쎲 Header: Logo Left, Logo Right, Title
Enter or browse for a bitmap graphics file to be printed.
쎲 Footer: Logo Bottom
Enter or browse for a bitmap graphics file to be printed.
Cover Page
You can specify several text entries and a logo (*.bmp) for the printout appearing on the cover page:
쎲 Logo: Enter or browse for a bitmap graphics file (*.bmp) to be printed.
쎲 Project, Comment, Prj. Number, Prj. Manager, PLC Type: Enter text for the respective entry fields.
4 – 36
MITSUBISHI ELECTRIC
Projects and Objects Printing Out Project Data
Left Footer
The following fields can be edited directly for the printout:
쎲 Rev, Change, Date, Name
쎲 Date, Drawn, Appr., Rel.
The captions for the entry fields can be edited by clicking on the respective caption button.
Right Footer
Enter any information into the blank entry fields.
POUs
The following options can be selected for the printout:
쎲 Header
If selected, the POU header for each selected POU will be printed.
쎲 Local Cross Reference
If selected the local reference for each selected POU will be printed.
쎲 Body
If selected, the following objects can be selected from the section Networks: Network
Cross Reference, Network Variable Lists, Cross ref./var. list after network
쎲 Either Multiple object on a page or Each object on a page
쎲 Use local variables in Cross Reference
쎲 Show header occurrences in Cross Reference
Page Numbers
The following options can be selected for the printout:
쎲 Show page number in cross reference
(Variable page reference)
쎲 Show page number in split reference
SFC
The following objects can be selected for the printout:
쎲 Main Network
쎲 Macros
쎲 Steps
쎲 Transitions
쎲 Actions
쎲 Table of Content
쎲 More steps/actions/transitions on one sheet
GX IEC Developer Reference Manual 4 – 37
Cross Reference
4.11
Projects and Objects
Cross Reference
The Cross Reference function generates a database listing of all the project variables.
Relationships become clearer, it is easier to find certain variables, and unused variables can be identified.
Default settings in the MMP703.INI initialisation file
[CrossReference]
GenerateSCT=TRUE
TRUE: cross reference function enabled.
FALSE: cross reference function disabled.
Cross reference options
In the Extras - Options - Cross Reference menu you can set the cross reference options.
Fig. 4-32:
Options -
Cross Reference
4 – 38
Generate *.SCT files while checking a project: Activates generation of the SCT files during project checks
Automatically link the *.SCT files to the *.SCX file after ‘Rebuild All’: Activates automatic linking of the SCT files to the SCX file after compiling the project
Automatically link the *.SCT files to the .SCX file after ‘Build’: Activates automatic linking of the SCT files to the SCX file after building the project
To create a cross reference database
햲 Compile the entire project.
햳 In the Project menu choose the command Make Cross Reference.
The program now compiles all the details required for the cross reference database.
The procedure is documented in the status window Cross Reference Linker. The time needed for this procedure depends on the project length.
MITSUBISHI ELECTRIC
Projects and Objects Cross Reference
Fig. 4-33:
Creating the cross reference database
햴 Choose Browse in the Project menu.
The Browser dialogue box is presented, prompting you to enter the search criteria.
Fig. 4-34:
Cross reference specification
Query
Set the search criteria:
Variable / Address: Contains <ALL> if searching for all or input an identifier
Search for: The search for the identifier is for variables and addresses, or only for variables and only for addresses.
Name Space: Object name; e.g. Program Organisation Unit, Global Variable List
Data Type: e.g. BOOL, INT
Scope: Class; e.g. VAR, VAR_GLOBAL
Button: Search: Starts the search. The result of the search is presented in the windows.
hits: Number of matches found
GX IEC Developer Reference Manual 4 – 39
Cross Reference Projects and Objects
Search result in window
All records that have been found are listed alphabetically.
Declares/References
Depending on the element that is marked in the left-hand window after a search, further details are listed in the right-hand window and in the Variable Info List. You can set further search filters for these details.
Filters
Namespace: Object name
Access: Tells you how the variable is accessed in the projects
Search result in window
Declaration: Program organisation units in which the variable was declared
References: Program organisation units in which the variable was inserted
Search result in the Variable Info List
Name: Name of variable
Type: Data type
Scope: Class; e.g. VAR, VAR_GLOBAL
Access: Access type; e.g. Read, Write, Read and Write
Editor: Programming language, network number in editor
NOTES
The browser functionality regarding search of variables is performed by their hardware address in Mitsubishi format and their address ranges. The search for a hardware address finds all variables that share the searched address.
In the case of an array element with non static index, i.e. the index part contains one or more indices that do not represent a number, the whole array range is used for the address search.
DUT or ARRAY of DUT can only be searched for the start address.
Functions that have address ranges passed by start address and block size like in BMOV,
FMOV, FROM, TO, or BXCH can only be searched for the start address.
4 – 40
MITSUBISHI ELECTRIC
Projects and Objects Double Coil Check
4.12
NOTE
Double Coil Check
The tool can be used to find potential problems in the project, as it looks for duplicate outputs to the same bit device or bit of a word device.
This function is not available for Remote I/O projects.
This function scans the generated code of a program. The following instructions and devices will be detected as a duplicate coil usage.
OUT(H)
Y, M, L, B, F
T, C
쏹
쏹
Tab. 4-1:
With the A series
SET,
RST
쏹
쎻
SFT(P)
쏹
쎻
PLS,
PLF
쏹
쎻
MC
쏹
쎻
OUT(H)
SET,
RST
X, Y, M, L, B, F,
SM, DY, SB,
Jn/X, Jn/Y,
Jn/B, Jn/SB
DY
D, SD, W,
SW, R, ZR,
Jn/W, Jn/SW,
Un/G
T, ST, C
V
쏹
쏹
쏹
쏹
쎻
쏹
쏹
쏹
쎻
쎻
Tab. 4-2:
With the Q/QnA series
SFT(P)
쏹
쏹
쏹
쎻
쎻
PLS,
PLF
쏹
쏹
쏹
쎻
쎻
EGP,
EGF
쎻
쎻
쎻
쎻
쏹
MC
쏹
쏹
쏹
쎻
쎻
FF DELTA(P)
쏹
쏹
쏹
쎻
쎻
쎻
쏹
쎻
쎻
쎻
OUT
Y, M
D
(FX3U(C) only)
S
T, C
쏹
쏹
쏹
쏹
Tab. 4-3:
With the FX series
SET,
RST
쏹
쏹
쏹
쎻
PLS,
PLF
쏹
쎻
쎻
쎻
MC
쏹
쎻
쎻
쎻
쏹: Applicable 쎻: Not applicable
When you call the menu command Extras Double Coil Check, it is checked if the project is compiled and the generated code is up to date.
A message will be displayed if the check cannot be performed because the code is not up to date. The check then is not performed.
GX IEC Developer Reference Manual 4 – 41
Double Coil Check Projects and Objects
If the check can be performed, the project is scanned for duplicate coils.
If no duplicate coils exist in the code, the following message is displayed:
Fig. 4-35:
Dialogue box, when no duplicate coils exist
If duplicate coils are found in the project, a modeless dialog will be opened to display the results.
Initially the items in the list are ordered by the name of the device.
Items corresponding to the same device will be sub-ordered by their occurrence in the generated code:
쎲 first the MAIN program
쎲 then the SUB program and the SFC program
– and within those in ascending step number order
4 – 42
Fig. 4-36:
Example of the dialogue window, when duplicate coils exist
Duplicate coils
Device: Column to display the device that is written
Program: Column to display the program where the device is written
Step: Column to display the position where the device is written
Source: Column to display the name of POU, action or transition where the device writing originates from
Call tree: Column to display the call tree of the POU where the device writing originates from
MITSUBISHI ELECTRIC
Projects and Objects Double Coil Check
Filter by instruction
Filter results by taking coils into account only when used with the selected instructions.
Check one or more checkboxes for activating the desired instructions.
The set of available check boxes varies with the PLC family.
Fig. 4-37:
Available check boxes for the Q and QnA series
Fig. 4-38:
Available check boxes for the A series
NOTES
Fig. 4-39:
Available check boxes for the FX series
The state of the OUT checkbox affects results for both the OUT and the OUTH instructions.
The state of the SFT checkbox affects results for both the SFT and the SFTP instructions.
The state of the DELTA checkbox affects results for both the DELTA and the DELTAP instructions.
All: Check all checkboxes
None: Uncheck all checkboxes
Minimize dialog after Show: Minimizes the window when the Show button is clicked
Re-check: Re-executes the check. Since the dialogue is modeless, the project can be changed after displaying the results. Using the button Re-check enables you to perform the check again and update the results.
Show: Jumps to the location of the marked coil in the source
Close: Close the dialogue window
NOTES
Other windows can be used, while the dialogue Double Coil Check is opened.
When selecting the menu command Extras Double Coil Check again, while the dialogue Double Coil Check is already opened, the dialogue will be activated (shown in the foreground).
If the dialogue is closed and opened again via the menu command Extras
Double Coil
Check, it will be displayed in the same state as it was before being closed (i.e. the results of a former check will be displayed). But if the project was closed or built, or the PLC type of the project was changed while the dialogue was not open, a re-check will be automatically performed.
The dialogue will be automatically closed if the project is closed or the PLC type of the project is changed.
GX IEC Developer Reference Manual 4 – 43
Double Coil Check Projects and Objects
4.12.1
NOTE
Example
Filtering the Results
Using the set of checkboxes below the result table, the results can be filtered by displaying the occurrences of only those duplicate coils that are used with the specified instructions.
Since the filtering works on the results, there is no need to execute the check again. The result table will be immediately refreshed when the filter settings are changed.
Initially all checkboxes are checked, but the changes made in the filter options will be preserved after the dialogue is closed, even after GX IEC Developer is exited.
For example, in the following simple POU Y0, Y1 and Y2 are written more than once using normal, set, and reset coils. The normal coil corresponds to the OUT instruction, while the setand reset coils correspond to the SET and RST instructions, respectively.
Fig. 4-40:
Example for a simple POU
4 – 44
MITSUBISHI ELECTRIC
Projects and Objects Double Coil Check
When executing Double Coil Check, and turning on all filter checkboxes, all duplicate coils will be shown in the result table.
Fig. 4-41:
Double Coil Check result, if all checkboxes are set
If the filter is reduced to only the OUT instruction, the result table will show only the coils that write the same device using the OUT instruction.
In this case these are only the coils that write the Y0 device. Although Y2 is also written u sing the OUT instruction, it will not be displayed in the results, because an OUT instruction is used only once with Y2. The other two coils use SET and RST, which are filtered out in this case.
Fig. 4-42:
Double Coil Check result, if only the checkbox OUT is set
GX IEC Developer Reference Manual
쑶
4 – 45
Double Coil Check
NOTE
Projects and Objects
When the functionality is started or a re-check is performed, it can happen that although there are duplicate coils in the project, none of them is visible in the result list, because they are filtered out.
In such a situation you will be informed by the following message.
Fig. 4-43:
Dialogue box with warning message
4.12.2
Sorting the Results
It will be possible to sort the results by clicking on any of the column headers. The following table lists the sorting criteria used when clicking a header:
Column
Device
Criteria
Sorted by device names in alphabetic order, and within that by program and occurrence order
(default)
Program
Step
Source
Call tree
Sorted by program type (MAIN
씮 SUB 씮 SFC) and within that by occurrence order
Sorted by object names in alphabetic order, and within that by occurrence order
Sorted by call tree strings in alphabetic order, and within that by occurrence order
Tab. 4-4:
Sorting criteria of each column
4 – 46
MITSUBISHI ELECTRIC
Projects and Objects
4.12.3
Double Coil Check
Showing the Location of the Coil in the Source
The following methods are provided to show the location of the coil in the source code:
쎲 Selecting a row and clicking the Show button
쎲 Selecting a row and pressing the Enter key
쎲 Double-clicking a row
Fig. 4-44:
Showing the location of the coil in the source code
The location of the coil can be displayed on the following detail level in the various body, action and transition languages:
Language
LD / FBD
IL / MELSEC IL
ST
SFC
Position
The body will be opened and the network will be marked.
The body will be opened and the line will be marked.
The body will be opened and the line will be marked.
The body will be opened.
Tab. 4-5:
Displaying the location of a coil
GX IEC Developer Reference Manual 4 – 47
Double Coil Check
NOTES
Projects and Objects
Since the dialogue is modeless, it is possible to change the project after displaying the results. In this case there is a chance that the original location of the coil is moved or deleted, so jumping to that point in the source code will produce false results.
A confirmation message will be displayed when you want to see the location of the coil, but the project was changed since the check.
In case of the SFC program in A-series projects no location information will be available.
The device name and program name will be displayed, but the fields Step, Source and Call
tree will include a dash (—) only, and the button Show will be grayed.
There are situations in which the location of the coil cannot be shown (e.g. because of security settings or because the container body is in a closed library, etc.).
In this case the corresponding editor will display a message explaining the reason, and the
Double Coil Check dialogue will be kept active.
4 – 48
MITSUBISHI ELECTRIC
Projects and Objects Verifying Projects
4.13
NOTES
Verifying Projects
By using the function of verifying projects you can verify an opened project with an other project. This function is based on the functionality of Verify in the menu Project - Transfer
While the functionality of online verify compares the opened project to the one downloaded to the PLC, the functionality of project verify will compare the currently opened project to another project on the PC, selected by the user.
To verify two projects choose the menu Project, the sub menu Other and then Verify. In the opened dialogue box select the desired project to be compared with the current project.
The following project elements will be verified:
쎲 Boot settings (boot files) (if the PLC is of the Q/QnA series, except Q Remote I/O projects)
쎲 PLC-Parameters
쎲 Main program
쎲 Sub program (if allowed for the PLC type)
쎲 SFC program (if allowed for the PLC type)
쎲 SFC program file header (if SFC is allowed for the PLC type, and it is of the Q/QnA series)
쎲 Timer initial values of main and sub program (if the PLC is of the A series)
쎲 Counter initial values of main and sub program (if the PLC is of the A series)
The opened project will not be closed (only its database file will be closed). Therefore you do not have to save the project before starting the comparison.
The comparison is separated into two parts: the PLC-parameter and the program. Both projects have to include parameters to start the parameter verification, otherwise the parameters are incomparable.
The program comparison is not only based on the compiled code, so the two projects do not have to be compiled to start the program verification. The projects will also be considered to have been changed if unsaved changes exist in any open editors. The user will be warned, if either project has been changed since last build.
The for comparison selected project may not be opened in the current or another GX IEC
Developer instance. Consequently a project cannot be compared to itself.
An improperly closed project cannot be compared to the opened project. It must be repaired first by opening it in GX IEC Developer normally.
A project last saved with a newer version of GX IEC Developer cannot be compared to the currently opened project.
A project last saved with a version of GX IEC Developer older than 4.00 cannot be compared to the currently opened project. It must be converted first by opening it in GX IEC Developer normally.
Parameters of a project last saved with a version of GX IEC Developer older than 6.00
cannot be compared to the current project’s parameters. The project must be converted first by opening it in GX IEC Developer normally.
Only projects for the same CPU type can be compared.
GX IEC Developer Reference Manual 4 – 49
Verifying Projects Projects and Objects
NOTE
In case of a Q Remote I/O project, the verify function compares only parameters, because a
Q Remote I/O project does not have program data. If the comparison is successful (no error happens), the possible results are:
앫 PLC-Parameter identical
앫 PLC-Parameter not identical
If the parameters cannot be compared due to an error, the error will be displayed in a message box and the Verify Result Messages dialogue will not be shown.
After the chosen project is read, the comparison results will be displayed in the dialogue Verify
Result Messages shown below. This is the same dialogue as for online verify (see also
Fig. 4-45:
Dialogue box
The PLC parameters are compared in whole (having the incomparable blocks removed), so there may be two cases: identical or not identical. The program will be compared part-by-part
(e.g. main program, SFC program, etc.), and for each not identical part a message is displayed in the dialogue. If the comparison shows no difference in any of the program's elements, then only the message "Program identical" is displayed. Additionally, there are messages indicating if an element exists in either project but not in the other.
The following table lists the messages related to the various project elements. These messages are the same as for online verify.
Element
Boot file
Parameter
Main program
Sub program
SFC program
SFC program file header
Timer initial values (main program)
Timer initial values (sub program)
Counter initial values
(main program)
Counter initial values
(sub program)
“Identical” message
"Boot file identical"
"PLC-Parameter identical"
"Program identical"
“Not identical” message
"Boot file not identical"
"PLC-Parameter not identical"
"Main-Program not identical"
"Sub-Program not identical"
"SFC-Program not identical"
"SFC-Program file header not identical"
"Timer-setting Values of
Main-Program not identical"
"Timer-setting Values of
Sub-Program not identical"
"Counter-setting Values of
Main-Program not identical"
"Counter-setting Values of
Sub-Program not identical"
Tab. 4-6:
List of Messages related to the command Verify
4 – 50
MITSUBISHI ELECTRIC
Projects and Objects Verifying Projects
The following table lists the messages displayed if an element is missing from either or both projects. These messages are the same as for online verify.
Element Absence Message
Boot file
Parameter
Main program
Missing from either or both projects
Missing from chosen project
Missing from either or both projects
"Boot file incomparable"
"PLC-Parameter incomparable"
"Program incomparable"
Remark
If the selected project is older than version 6.00 or the boot file of either project was deleted.
If an error happens at the reading of one of the boot files because the boot file is corrupted.
If the parameter of one of the projects is security protected.
It is impossible to open a project without parameters, so the parameters are never missing in the currently open project.
If there is no main program in either or both projects a comparison is not possible.
Sub program
Missing from either project
"Sub-Program exists in current, but not in selected project" or
"Sub-Program exists in selected, but not in current project"
If there is no sub program in either of the projects a comparison is not possible.
Sub program
Missing from both projects
—
If there is no sub program in both of the projects a comparison will not be performed.
SFC program
Missing from either project
"SFC-Program exists in current, but not in selected project" or
"SFC-Program exists in selected, but not in current project"
If there is no SFC program in either of the projects a comparison is not possible.
SFC program
SFC program file header
Timer/counter initial values
Missing from both projects
Not covered
Not covered
—
—
—
If there is no SFC program in both of the projects a comparison will not be performed.
A SFC program header always exists in Q/QnA projects if a SFC program exists.
These initial values always exist in projects for A series
CPUs.
Tab. 4-7:
List of Messages displayed if an element is missing
Detected differences in the program code can be shown in a Main or Sub Program Differ-
ence window via the Show button. The verify results are listed as recompiled MELSEC IL, the differences are highlighted in the error color. The left part of the window lists the current project code, the right part of the window lists the selected project code.
When the Main or Sub Program Difference window is opened the following menu items are available in the Tools menu:
Next Difference: Next Difference or the tabulator key will position the text in the window so that the first line of the next difference is the top most line. The top most line will be selected.
The according calltree, number of network and for IL and ST the line in the network of the selected line are shown in the status bar. If no next difference exists, the menu item is greyed.
Previous Difference: Previous Difference or the shift tabulator key will position the text in the window so that the first line of the previous difference is the top most line. The top most line will be selected. The according calltree, number of network and for IL and ST the line in the network of the selected line are shown in the status bar. If no previous difference exists, the menu item is greyed.
GX IEC Developer Reference Manual 4 – 51
Verifying Projects Projects and Objects
Goto Editor: Goto Editor or a double click on a selected line will open the according POU body. In IL/ST the according line and in LD/FBD the according network is positioned to the visible area and marked with the browser colour in the network column.
If no POU body relates to the selected line a message window is opened to inform you of this circumstance. The message text is “The selected line belongs to code generated for task or program handling. No editor could be opened.”
Show Step Number: This menu item is checked as default. If it is checked, the step number for each instruction for the code of the current project and the selected project are displayed.
If it is not checked, the step numbers are not displayed. If a line is selected and the step number is not displayed, the line is marked with a small box in front of the instruction.
4 – 52
MITSUBISHI ELECTRIC
Parameters
5 Parameters
PLC Parameter
5.1
NOTE
PLC Parameter
The command Parameter - PLC in the Project Navigator provides options for configuring your system.
The CPU type can be changed by selecting the command Change PLC Type in the Project menu or by clicking on the icon.
In the dialogbox Change PLC Type you can select a PLC series and a PLC type.
쎲 If you change the PLC series and/or the PLC type and confirm with OK, all parameters for the new PLC type will be reset to defaults.
쎲 If you do not change the PLC series/PLC type but want all previous parameter changes to become inactive, confirm with OK.
쎲 If you do not want to change anything, click Cancel.
The default settings produce trouble-free program performance for most applications. If you are using a network you must configure it with Parameter - Network before starting work, however. If the configuration parameter settings lead to problems in your project, GX IEC
Developer will display an explanatory warning message.
The PLC parameters are set automatically for the PLC type you select. Some of the parameters explained below are not relevant for all PLC types, and they are thus not displayed when some specific PLC types are selected.
For any information or particular explanation required for parameter setting, refer to the corresponding CPU user's manual and programming manual to pre-design them. The setting items are assigned to the tab screen purpose-by-purpose.
Fig. 5-1:
Parameters
GX IEC Developer Reference Manual 5 – 1
PLC Parameter Parameters
5.1.1
Setting the PLC Parameters
The following table lists the PLC parameter setting items on a series basis. Set the parameters as required.
A QnA
PLC name
PLC system (1)
PLC system (2)
Positioning
PLC file
PLC RAS (1)
PLC RAS (2)
Device
Program
Boot file
SFC
I/O assignment
Memory capacity
Operational settings
Serial
쎻
쎻
쎻
쎻
쏹
쎻
쏹
쎻
쏹
쎻
쎻
쏹
쎻
쏹
쎻
Tab. 5-1:
PLC parameter setting items
쎻
쎻
쏹
쏹
쏹
쎻
쏹
쏹
쎻
쎻
쏹
쏹
쏹
쏹
쎻
Q00J/Q00/
Q01
쏹
쏹
쏹
쎻
쏹
쏹
쎻
쎻
쏹
쏹
쏹
쏹
쎻
쎻
쏹
QnH
쎻
쎻
쏹
쏹
쏹
쏹
쏹
쏹
쎻
쎻
쏹
쏹
쏹
쏹
쎻
System Q
QnUDH
쎻
쎻
쏹
쏹
쏹
쏹
쏹
쏹
쎻
쎻
쏹
쏹
쏹
쏹
쎻
QnPH
쎻
쎻
쏹
쏹
쏹
쏹
쏹
쏹
쎻
쎻
쏹
쏹
쏹
쏹
쎻
QnPRH
쎻
쎻
쏹
쏹
쏹
쏹
쏹
쏹
쎻
쎻
쏹
쏹
쏹
쏹
쎻
쎻
쎻
쎻
쎻
쏹
쎻
쏹
쎻
쏹
쏹
쎻
쎻
쏹
쏹
쏹
Remote
I/O
쎻
쎻
쏹
쎻
쎻
쎻
쎻
쎻
쎻
쏹
쎻
쏹
쎻
쏹
쎻
FX
5.1.2
Common Notes on Parameters
Parameter display
This part describes the setting item tabs and network parameter setting items.
Example
Fig. 5-2:
QnA Parameter
The meanings of the symbols are the same also when displayed with network parameters.
쑶
쎲 Red: The PLC does not operate until data is set. (Data is not set.)
쎲 Blue: Data is set.
쎲 Magenta: The PLC operates without setting data or with the default. (Data is set.)
쎲 Dark blue: Data is set.
5 – 2
MITSUBISHI ELECTRIC
Parameters
Common buttons for parameters
This part describes the settings common to PLC and network parameters.
PLC Parameter
Fig. 5-3:
Common buttons for parameters
Default button
This button returns all of the set items or values to the previous settings. This button is available only for the currently open tab.
Check button
Use this button to check the set items or values to see if they are correct. This button is available only for the currently open tab.
End setup
The End button defines the set items or values and terminates the setting.
Cancel button
Cancels the set items and terminates editing.
Acknowledge X/Y Assignment button
This button is available for the models A2ACPU(S1), A3ACPU, A2AS(S1), A2AS-S30,
A2AS-S60, A2UCPU(S1), A2USCPU(S1), A2USHCPU(S1), A3UCPU, and QnACPU,
QCPU(Q mode). It is used to confirm the X/Y assignment numbers of the data set in the I/O assignment setting.
Fig. 5-4:
XY Assignment
GX IEC Developer Reference Manual 5 – 3
PLC Parameter Parameters
Display
I/O assignment
MINI
CC-Link
NET (II)
NET/10
Description
Displays I/O assignment information.
Displays I/O assignment information and MINI automatic refresh setting information.
Displays I/O assignment information and CC-Link automatic refresh setting information.
Master station: Displays I/O assignment information and refresh parameter information.
Local Station:
PLC-to-PLC network, remote I/O network:
Displays I/O assignment information and refresh parameter information.
Displays network parameter information.
Tab. 5-2:
Display by type
The priority of display is shown below:
햲 I/O assignment (AnACPU, AnUCPU, Q/QnA series)
햳 Fourth MELSECNET network refresh parameter (AnUCPU, Q/QnA series)
햴 Third MELSECNET network refresh parameter (AnUCPU, Q/QnA series)
햵 Second MELSECNET network refresh parameter (AnUCPU, Q/QnA series)
햶 First MELSECNET network refresh parameter (AnUCPU, Q/QnA series)
햷 MELSECNET/MINI refresh (AnACPU, AnUCPU, QCPU (A mode)/QnA series)
햸 CC-Link remote I/O (Q/QnA series)
The Duplicate Error area displays the first duplicate item detected in checking the items according to the priority.
5 – 4
MITSUBISHI ELECTRIC
Parameters PLC Parameter
Multiple CPU setting button
Setting cannot be made for Q00J/Q00/Q01CPU and remote I/O projects.
Multiple CPU settings
No. Of PLC
Set one to four modules.
Host CPU number
Set the number of the Host CPU.
Operating mode
Set the operation (stop) at a PLC stop error.
Multiple CPU synchronous startup setting
Set the target PLC.
Online module change
Make setting when performing online module change.
I/O sharing when using Multiple CPUs
Specify the shared I/Os.
Communication area setting
Set the CPU shared memory G between multiple CPUs.
Usable devices: B, M, Y, D, W, R, ZR
Multiple CPU high speed transmission area setting
(QnU CPU only, except Q02U)
Make settings to use Multiple CPU high speed transmission
Fig. 5-5:
Multiple PLC setting
No. of PLC
Clicking the Default button in I/O assignment keeps the multiple PLC setting unchanged.
When the set number of PLCs is one, a multiple CPU system configuration is not set.
Host CPU setting
When the modules are not grouped, they are all put under the control PLC of the PLC No. 1.
OPERATION ERROR appears if access is made to any module outside the groups.
Communication area setting (Refresh setting)
The maximum input range of each module is 0 to 2048 points.
Set the total number of all modules to within 4096 points.
Multiple CPU high speed transmission area setting
Set the total number of all modules to within 12k points.
Assignment confirmation button
Click this button to open a window showing a schematic diagram of the division of the PLCs' shared memory.
GX IEC Developer Reference Manual 5 – 5
PLC Parameter
5.1.3
Parameters
PLC Parameter Item Lists
PLC parameter item list of the Qn(H) and QnU(D)(E)(H)
PLC name PLC file
Device Label
Set the CPU label.
Comment
Set the CPU comment.
PLC system
Timer limit setup
Set the time limits of the low-/high-speed timers.
RUN-PAUSE contacts
Make setting to control RUN/PAUSE of the CPU.
Latch data backup operation valid contact
(QnU CPU only)
Make setting for contact to trigger latch data backup.
Remote reset
Set enable/disable of remote reset operation.
Output mode at STOP to RUN
Set the output mode at STOP to RUN.
Floating point arithmetic processing (QnH CPU only)
Make setting to perform floating point arithmetic operation at high speed.
Intelligent functional module setting
Set the assignment of the interrupt pointers (I50 to I255) and the first I/O No. and first SI No. of the intelligent function unit.
Common pointer
Set the first No. of the common pointers.
Number of empty slots
Set the number of empty slots.
System interrupt settings
Set the first No. of the interrupt counters (QnH CPU only) and the fixed scan intervals of the interrupt pointers.
Interrupt program/Fixed scan program setting
Set whether the interrupt/fixed scan program is run at high speed or not.
Modul synchronization
Set whether the start of the Q CPU is synchronized with that of the intelligent function unit.
Compatibility with A-PLC (QnH CPU only)
Set whether the special relays/special registers for MELSEC-A series (SM1000/SD1000 and later) are used or not.
Service processing setting (QnU CPU only)
Set the service processing time.
Device
Fig. 5-6:
PLC parameter item list of the QnH, QnU (1)
File register
Set the file register file to be used.
Comment file used in a command
Set the comment file to be used in a command.
Device initial value
Set the device initial value file to be used.
File for local device
Set the local device file to be used.
File used for SP.DEVST/S.DEVLD
instruction (QnU CPU only)
Set whether and if which file is used.
Dev. Point
Set the number of device points to be used.
Latch [1] start
Set the latch range valid for latch clear key operation.
Latch [2] start
Set the latch range invalid for latch clear key operation.
Local dev. Start
Set the range of the device used as a local device.
Latch setting of file register
(QnU CPU only)
Set the latched range for the file register.
Indexing setting of ZR device
(QnU CPU only)
Specify 32-bit indexing of file register after a given Z device.
5 – 6
MITSUBISHI ELECTRIC
Parameters PLC Parameter
PLC RAS
WDT [Watchdog timer] setup
WDT setting
Initial execution
Low speed execution (QnH CPU only)
Make WDT settings of the CPU.
Error check
Set whether the specified error is to be detected or not.
Operating mode when there is an error
Set the display mode of the CPU on detection of an error.
Constant scanning
Set the constant scan time.
Low speed program execution time (QnH CPU only)
Set the time for execution of a low-speed program.
Breakdown history (QnH CPU only)
Set the storage target of the CPU's breakdown history.
SFC
SFC
Make various settings needed for an
SFC program.
I/O assignment
I/O assignment
Set each unit loading status of the system.
Make switch settings of the intelligent function module.
Reserve the multiple CPUs.
(Refer to the items common to the
PLC parameters for the multiple
PLC setting.)
Base setting
Set the base model, power supply module model, etc.
Program
Program
Set the execution type for use of multiple programs.
Boot file
Boot file setup
Set the boot-run file, etc.
Fig. 5-6:
PLC parameter item list of the QnH , QnU (2)
Built-in Ethernet port
(QnUDE(H) CPU only)
IP address
Set the IP address etc.
Communication data code
Set binary code or ASCII code.
GX IEC Developer Reference Manual 5 – 7
PLC Parameter Parameters
PLC parameter item list of the QnPH
PLC name PLC file
Device Label
Set the CPU label.
Comment
Set the CPU comment.
PLC system
Timer limit setup
Set the time limits of the low-/high-speed timers.
RUN-PAUSE contacts
Make setting to control RUN/PAUSE of the CPU.
Remote reset
Set enable/disable of remote reset operation.
Output mode at STOP to RUN
Set the output mode at STOP to RUN.
Floating point arithmetic processing
Make setting to perform floating point arithmetic operation at high speed.
Intelligent functional module setting
Set the assignment of the interrupt pointers (I50 to I255) and the first I/O No. and first SI No. of the intelligent function unit.
Common pointer
Set the first No. of the common pointers.
Number of empty slots
Set the number of empty slots.
System interrupt settings
Set the first No. of the interrupt counters and the fixed scan intervals of the interrupt pointers.
Interrupt program/Fixed scan program setting
Set whether the interrupt/fixed scan program is run at high speed or not.
Unit synchronization
Set whether the start of the QCPU is synchronized with that of the intelligent function unit.
Compatibility with A-PLC
Set whether the special relays/special registers for MELSEC-A series (SM1000/SD1000 and later) are used or not.
Fig. 5-7:
PLC parameter item list of the QnPH (1)
Device
File register
Set the file register file to be used.
Comment file used in a command
Set the comment file to be used in a command.
Device initial value
Set the device initial value file to be used.
File for local device
Set the local device file to be used.
Dev. Point
Set the number of device points to be used.
Latch [1] start
Set the latch range valid for latch clear key operation.
Latch [2] start
Set the latch range invalid for latch clear key operation.
Local dev. Start
Set the range of the device used as a local device.
5 – 8
MITSUBISHI ELECTRIC
Parameters PLC Parameter
PLC RAS (1)
WDT [Watchdog timer] setup
WDT setting
Initial execution
Low speed execution
Make WDT settings of the CPU.
Error check
Set whether the specified error is to be detected or not.
Operating mode when there is an error
Set the display mode of the CPU on detection of an error.
Constant scanning
Set the constant scan time.
Low speed program execution time
Set the time for execution of a low-speed program.
Breakdown history
Set the storage target of the CPU's breakdown history.
PLC RAS (2)
Memory check
Set whether a program memory check will be made or not.
Program
Program
Set the execution type for use of multiple programs.
SFC
SFC
Make various settings needed for an
SFC program.
I/O assignment
I/O assignment
Set each unit loading status of the system.
Make switch settings of the intelligent function module.
Reserve the multiple CPUs.
(Refer to the items common to the
PLC parameters for the multiple
PLC setting.)
Standard setting
Set the base model, power supply module model, etc.
Boot file
Boot file setup
Set the boot-run file, etc.
Fig. 5-7:
PLC parameter item list of the QnPH (2)
GX IEC Developer Reference Manual 5 – 9
PLC Parameter Parameters
PLC parameter item list of the QnPRH
PLC name PLC file
Device Label
Set the CPU label.
Comment
Set the CPU comment.
PLC system
Timer limit setup
Set the time limits of the low-/high-speed timers.
RUN-PAUSE contacts
Make setting to control RUN/PAUSE of the CPU.
Remote reset
Set enable/disable of remote reset operation.
Output mode at STOP to RUN
Set the output mode at STOP to RUN.
Floating point arithmetic processing
Make setting to perform floating point arithmetic operation at high speed.
Intelligent functional module setting
Set the assignment of the interrupt pointers (I50 to I255) and the first I/O No. and first SI No. of the intelligent function unit.
Common pointer
Set the first No. of the common pointers.
Number of empty slots
Set the number of empty slots.
System interrupt settings
Set the first No. of the interrupt counters and the fixed scan intervals of the interrupt pointers.
Interrupt program/Fixed scan program setting
Set whether the interrupt/fixed scan program is run at high speed or not.
Unit synchronization
Set whether the start of the QCPU is synchronized with that of the intelligent function unit.
Compatibility with A-PLC
Set whether the special relays/special registers for MELSEC-A series (SM1000/SD1000 and later) are used or not.
Fig. 5-8:
PLC parameter item list of the QnPRH (1)
Device
File register
Set the file register file to be used.
Comment file used in a command
Set the comment file to be used in a command.
Device initial value
Set the device initial value file to be used.
File for local device
Set the local device file to be used.
Dev. Point
Set the number of device points to be used.
Latch [1] start
Set the latch range valid for latch clear key operation.
Latch [2] start
Set the latch range invalid for latch clear key operation.
Local dev. Start
Set the range of the device used as a local device.
5 – 10
MITSUBISHI ELECTRIC
Parameters PLC Parameter
PLC RAS (1)
WDT [Watchdog timer] setup
WDT setting
Initial execution
Low speed execution
Make WDT settings of the CPU.
Error check
Set whether the specified error is to be detected or not.
Operating mode when there is an error
Set the display mode of the CPU on detection of an error.
Constant scanning
Set the constant scan time.
Breakdown history
Set the storage target of the CPU's breakdown history.
SFC
SFC
Make various settings needed for an
SFC program.
I/O assignment
I/O assignment
Set each unit loading status of the system.
Make switch settings of the intelligent function module.
Standard setting
Set the base model, power supply module model, etc.
PLC RAS (2)
Memory check
Set whether a program memory check will be made or not.
Program
Program
Set the execution type for use of multiple programs.
Boot file
Boot file setup
Set the boot-run file, etc.
Fig. 5-8:
PLC parameter item list of the QnPRH (2)
GX IEC Developer Reference Manual 5 – 11
PLC Parameter Parameters
PLC parameter item list for Q series remote I/O station
PLC system settings I/O assignment settings
Number of vacant slot points
Set the number of vacant slot points.
Module synchronization setting
Set whether a QCPU startup is synchronized with an intelligent function module startup or not.
I/O assignment settings
Set the module loading states of the system.
Make the switch settings of the intelligent function module.
Basic settings
Set the base type, power supply module type, etc.
PLC RAS settings
Error check
Set whether the specified error will be detected or not.
Operating mode when there is an error
Set whether operation will be stopped or not at occurrence of a fuse blown or I/O module comparison error.
Operation settings
Remote I/O station switch settings
Set cyclic communication error-time output hold and output hold designation enable.
Inter-device transfer parameters
Set the link device range, etc. for communication with the I/O and special function modules of each remote I/O station.
Fig. 5-9:
PLC parameter item list for Q series remote I/O station
5 – 12
MITSUBISHI ELECTRIC
Parameters PLC Parameter
PLC parameter item list of the Q00J/Q00/Q01CPU
PLC name
Device Label
Set the CPU label.
Comment
Set the CPU comment.
PLC file
(Setting is disabled for Q00J)
File register
Set the file register file to be used.
(Setting is fixed)
PLC system
Timer limit setup
Set the time limits of the low-/high-speed timers.
RUN-PAUSE contacts
Make setting to control RUN/PAUSE of the CPU.
Remote reset
Set enable/disable of remote reset operation.
Output mode at STOP to RUN
Set the output mode at STOP to RUN.
Number of empty slots
Set the number of empty slots.
System interrupt settings
Set the first No. of the interrupt counters and the fixed scan intervals of the interrupt pointers.
Interrupt program/Fixed scan program setting
Set whether the interrupt/fixed scan program is run at high speed or not.
Unit synchronization
Set whether the start of the QCPU is synchronized with that of the intelligent function unit.
Device
Dev. Point
Set the number of device points to be used.
Latch [1] start
Set the latch range valid for latch clear key operation.
Latch [2] start
PLC RAS
I/O assignment
WDT [Watchdog timer] setup
WDT setting
Make WDT settings of the CPU.
Error check
Set whether the specified error is to be detected or not.
Operating mode when there is an error
Set the display mode of the CPU on detection of an error.
Constant scanning
Set the constant scan time.
Boot file Serial
I/O assignment
Set each unit loading status of the system.
Make switch settings of the intelligent function module.
Reserve the multiple CPUs.
Standard setting
Set the base model, power supply module model, etc.
(Setting is disabled for Q00J)
Boot file setup
Set the boot-run file, etc.
Fig. 5-10:
PLC parameter item list of the Q00J/Q00/Q01CPU
Baud rate
Set the baud rate.
Sum check
Set the sum check.
Transmission wait time
Set the transmission wait time.
RUN write setting
Set whether online program change can be made or not.
GX IEC Developer Reference Manual 5 – 13
PLC Parameter Parameters
PLC parameter item list of the QnA series
PLC name
Device label
Set the CPU label.
Comment
Set the CPU comment.
PLC system
Timer limit setup
Set the time limits of the low-/high-speed timers.
RUN-PAUSE contacts
Make setting to control RUN/PAUSE of the CPU.
Remote reset
Set enable/disable of remote reset operation.
Output mode at STOP to RUN
Set the output mode at STOP to RUN.
General data processing
Set the number of units to be handled by single general data processing.
Common pointer
Set the first No. of the common pointers.
Number of empty slots
Set the number of empty slots.
System interrupt settings
Set the first No. of the interrupt counters and the fixed scan intervals of the interrupt pointers.
PLC file
File register
Set the file register file to be used.
Comment file used in a command
Set the comment file to be used in a command.
Device initial value
Set the device initial value file to be used.
File for local device
Set the local device file to be used.
Device
Dev. Point
Set the number of device points to be used.
Latch [1] start
Set the latch range valid for latch clear key operation.
Latch [2] start
Set the latch range invalid for latch clear key operation.
Local dev. Start
Set the range of the device used as a local device.
PLC RAS
WDT [Watchdog timer] setup
WDT setting
Initial execution
Low speed execution
Set the WDT timers of the CPU.
Error check
Set whether the specified error is to be detected or not.
Operating mode when there is an error
Set the display mode of the CPU on detection of an error.
Constant scanning
Set the constant scan time.
Low speed program execution time
Set the time for execution of a low-speed program.
Annunciator display mode
Display F No.
Display comment
Display occurrence time
Set the display mode established when the annunciator has turned on.
Breakdown history
Set the storage target of the CPU's breakdown history.
Fig. 5-11:
PLC parameter item list of the QnA series
SFC
SFC
Make various settings needed for an
SFC program.
I/O assignment
I/O assignment
Set each unit loading status of the system.
Standard setting
Set the base model, power supply unit model, etc.
Program
Program
Set the execution type for use of multiple programs.
Boot file
Boot file setup
Set the boot-run file, etc.
5 – 14
MITSUBISHI ELECTRIC
Parameters PLC Parameter
PLC parameter item list of the A series
Memory capacity PLC system
Program capacity
Set the main, sub, microcomputer and other capacities.
Comment
Set the comment capacity.
Expanded comment
Set the extended comment capacity.
File register
Set the file register capacity.
Capacity for debugging
Set the sampling trace and status latch capacities.
Memory capacity information
Display the total of memory to be used.
RUN-PAUSE contacts
Set the contacts which control RUN/PAUSE of the CPU.
System interrupt setup
Set the range of the counter used in an interrupt program.
Output mode at STOP to RUN
Set the output status at STOP to RUN.
Data communications request batch processing
Set whether the transient communications request is processed or not in the END processing of its scan.
PLC RAS
Remote I/O setting for A2C PLC
Set the occupied slot count and remote I/O assignment of each station when the
A2C/A2CJCPU is selected.
WDT setup
Set the WDT.
Operating mode when there is an error
Set whether operation will be stopped or continued at occurrence of a fuse blow, operation error,
I/O unit verify error or special unit access error.
Annunciator display mode
Set whether annunciator display is provided or not.
I/O assignment
I/O assignment
Set the type (empty, input, output, special), model and points.
Fig. 5-12:
PLC parameter item list of the A series
Device
Device setup
Set the points and latch range of each device used in a sequence program.
GX IEC Developer Reference Manual 5 – 15
PLC Parameter Parameters
PLC parameter item list of the FX series
Memory capacity
Memory capacity
Set the memory capacity that the PLC has.
Comment capacity
Set the comment capacity.
File register capacity
Set the file register capacity.
Program capacity
Set the sequence program capacity.
Device
Device setup
Set the latch range.
PLC name
PLC name
Comment the PLC program.
I/O assignment
I/O assignment
Set the first/last values of the I/O relays.
PLC system (1)
Battery less mode
Make this setting when performing operation without the memory backup battery of the FX2N,
FX2NC, or FX3UC PLC.
MODEM initialized
Set the modem initialization command when making remote access to the FX1S, FX1N, FX2N,
FX1NC, FX2NC, or FX3UC PLC
.
RUN terminal input
When using the input (X) of the
FX1NC, FX2NC, or FX3UC PLC
FX1S, FX1N, FX2N, as the external
RUN/STOP terminal, set its input number.
Fig. 5-13:
PLC parameter item list of the FX series
PLC system (2)
Protocol
Set the communication protocol.
Data length
Set the data length.
Parity
Set the parity.
Stop bit
Set the stop bit.
Transmission speed
Set the transmission speed.
Header
Set the header.
Terminator
Set when making the terminator valid.
Control line
Set when making the control line valid.
H/W type
Normally choose RS-232C or RS-485.
Control mode
Display the control mode data.
Sum check
Set when adding sum check.
Transmission control procedure
Choose format 1/format 4.
Station number setting
Make station number setting.
Time out judge time
Set the time-out period.
Positioning
Make common settings (single entry for each axis) and detailed settings
(multiple entries for each axis) in the parameter table of positioning control.
5 – 16
MITSUBISHI ELECTRIC
Parameters
5.1.4
PLC Parameter
Reading of PLC Parameter from the PLC
It is also possible to read the PLC parameter from the PLC to the Project.
Read PLC data button
This button is located on the I/O assignment tab.
For Q series:
The implementation status is read if the parameter file exists in the PLC. If the unit model, first
X/Y, base model, power supply unit model, extension cable model and slot count have been set on the Personal computer, the data will be deleted.
If the parameters have been set on GX IEC Developer, the following dialogue box appears to ask you if the parameter data may be overwritten.
Fig. 5-14:
Note when reading the PLC data
For QnA series:
When the parameter file exists in the PLC, the parameter file is read.
When the parameter file does not exist in the PLC (implementation read):
After deleting the parameter file in the PLC, set the PLC from RESET to RUN and read the PLC data. If the unit model, first X/Y, base, power supply unit and extension cable have been set on the Personal computer, the data will be deleted.
GX IEC Developer Reference Manual 5 – 17
Parameters for Redundant PLCs
5.2
Parameters
Parameters for Redundant PLCs
The command Parameter - Redundant PLC in the Project Navigator provides options for configuring a redundant system.
Fig. 5-15:
The Project Navigator window for the QnPRH CPU
Redundant PLC parameter item list of the QnPRH
Redundant Parameters
Operation settings
Start mode setting
Set the device status when the system is powered on/reset.
Standby system watch setting
Check for a stanby system fault.
If a fault occurs, error check can be made using the PLC diagnostics.
Debug mode setting
Set a start in the debug mode.
Backup mode setting
Set the same type of operating status consistency.
Tracking settings
Tracking device settings
Set the tracking transfer setting data.
Tracking characteristics settings
Set the transfer mode.
Fig. 5-16:
Redundant PLC parameter item list of the QnPRH
5 – 18
MITSUBISHI ELECTRIC
Parameters
5.3
Network Parameters
Network Parameters
The command Parameter - Network in the Project Navigator provides options for configuring your networks. Clicking on Parameter - Network opens the following dialogbox.
Fig. 5-17:
Dialogbox Network parameter
NOTE
If the network parameter settings lead to problems in your project, GX IEC Developer will display an explanatory warning message.
The PLC parameters are set automatically for the PLC type you select. Some of the parameters explained below are not relevant for all PLC types, and they are thus not displayed when some specific PLC types are selected.
For any information or particular explanation required for network parameter setting, refer to the corresponding CPU user's manual and programming manual to pre-design them. The setting items are assigned to the tab screen purpose-by-purpose.
5.3.1
Setting the Network Parameters
The following table lists the network parameter setting items on a series basis. Set the parameters as required.
System Q A
Network
AnNCPU AnACPU
MELSECNET
MELSECNET II
MELSECNET/10
MELSECNET/10H
MELSECNET/MINI
CC-Link
CC-Link Ver. 2
ETHERNET
쎻
쏹
쎻
쏹
쎻
쎻
쎻
쎻
쎻
쎻
쎻
쏹
쏹
쎻
쎻
쎻
Tab. 5-3:
Network parameter setting items
AnUCPU
QCPU
(A mode)
쎻
쏹
쎻
쏹
쏹
쏹
쎻
쎻
QnA
쎻
쏹
쏹
쏹
쏹
쏹
쎻
쏹
CPU
쏹
쎻
쏹
쎻
쎻
쏹
쏹
쏹
Remote I/O
쎻
쎻
쏹
쎻
쎻
쎻
쏹
쏹
GX IEC Developer Reference Manual 5 – 19
Network Parameters Parameters
5.3.2
Example
Common Notes on Parameters
About Items Common to the Network Parameters
This section describes operations common to the setting of data link system and network system parameters.
The following operations cannot be performed as those common to the parameters.
쎲 Cut, copy, paste
쎲 Home and End keys are invalid.
The meanings of the symbols are the same also when displayed with PLC parameters.
쎲 Red: The PLC does not operate until data is set. (Data is not set.)
쎲 Blue: Data is set.
쎲 Magenta: The PLC operates without setting data or with the default. (Data is set.)
쎲 Dark blue: Data is set.
MELSECNET II combined (master station) network range assignment parameter setting window
5 – 20
Fig. 5-18:
MELSECNET II combined (master station) network range
쑶
Check button
Use this button to check the set items or values to see if they are correct. This button is available only for the currently open tab.
End setup
The End button defines the set items or values and terminates the setting.
Cancel button
Cancels the set items and terminates editing.
MITSUBISHI ELECTRIC
Parameters Network Parameters
Acknowledge X/Y Assignment button
This button is available for the models A2ACPU(S1), A3ACPU, A2AS(S1), A2AS-S30,
A2AS-S60, A2UCPU(S1), A2USCPU(S1), A2USHCPU(S1), A3UCPU, and QnACPU,
QCPU(Q mode). It is used to confirm the X/Y assignment numbers of the data set in the I/O assignment setting.
Routing Parameters button
Set the routing parameters in the following dialogbox, that is opened by clicking the button.
Fig. 5-19:
Routing parameters
Interlink Transmission Parameters button
Set the interlink transmission parameters in the following dialogbox, that is opened by clicking the button.
Fig. 5-20:
Interlink Transmission Parameters
GX IEC Developer Reference Manual 5 – 21
Network Parameters
Assignment image button
The following dialogue is opened.
Parameters
Fig. 5-21:
Assignment image
5 – 22
MITSUBISHI ELECTRIC
Parameters
5.3.3
Network Parameters
Network Parameter Item Lists
Network parameter items of the Q series
For the remote I/O project, only Ethernet or CC-Link may be set.
MELSECNET/10
MELSECNET/H
MELSECNET/H
Remote I/O
Network type
Specify the MELSECNET/H·MELSECNET/10 mode,MELSECNET/10 or Ethernet.
Starting I/O No.
Set the first I/O No.
Network No.
Set the network No.
Total stations
Set the total number of (slave) stations.
Group No.
Set the group No.
Mode
Set the mode.
Network range type (Common parameters)
I/O Master station specification
Set the I/O master station on the LX/LY setting screen.
Reserved station specification
Specify the reserved station.
Equal assignment
Set when assigning the link device points of the specified stations equally.
Identical point assignment
Set the same points according to the preset total number of stations.
Supplementary s tings
Make the transient, lowetspeed cyclic and other settings.
Station inherent parameters
Set the station inherent parameters.
Refresh parameters
Set the refresh parameters.
Interrupt settings
Set the device code, detection method, interrupt condition, interrupt (SI) No., Etc.
Fig. 5-22:
Network parameter items of the Q series (1)
Network type
Specify the MELSECNET/H (remote master).
Starting I/O No.
Set the starting I/O No.
Network No.
Set the network No.
Total stations
Set the total number of (slave) stations.
Mode
Set the mode.
Network range type (Common parameters)
Reserved station specification
Specify the reserved station.
Equal assignment
Set when assigning the link device points of the specified stations equally.
Supplementary settings
Make the constant scan and the max. Number of return stations in one scan.
Refresh parameters
Set the refresh parameters.
Interrupt settings
Set the device code, detection method, interrupt condition, interrupt (SI) No., Etc.
GX IEC Developer Reference Manual 5 – 23
Network Parameters Parameters
CC-Link
Ethernet
Unit count
Set the number of units. (1 to 4 units)
Operational settings
Set the parameter name and data link abnormal station.
Type
Set the master/local/standby master station, etc.
Master station data link type
Fixed to "PLC parameter auto start".
Mode
Set the mode.
All connectcount
Set the number of slave stations connected.
(1 to 64 stations)
Remote input [RX]
Set the bit devices to be batch-refreshed.
Remote output [RY]
Set the bit devices to be batch-refreshed.
Remote register [Rwr]
Set the word devices to be batch-refreshed.
Remote register [Rww]
Set the word devices to be batch-refreshed.
Special relay [SB]
Set the bit devices to be batch-refreshed.
Special register [SW]
Set the bit devices to be batch-refreshed.
Retry count
Set the number of transmission retries.
Automatic reconnection station count
Set the number of stations automatically reconnected during 1 scan.
Wait master station No.
Set the station number of the standby master station.
PLC down select
Set whether data link is continued or stopped at a stop of the CPU.
Scan mode setting
Set whether sequence scans are synchronized or not.
Delay information settings
Set the link scan interval delay time.
Station information settings
Set the station type, number of occupied stations, etc.
Remote device station initial
Set the corresponding station number and procedure registration (operation, execution and other conditions).
Interrupt settings
Set the device code, detection method, interrupt condition, etc.
Fig. 5-22:
Network parameter items of the Q series (2)
Network type
Specify the MELSECNET/10H mode or
Ethernet.
Starting I/O No.
Set the starting I/O No.
Network No.
Set the network No.
Group No.
Set the group No.
Station No.
Set the station number.
Mode
Set the mode.
Operational settings
Make the communications data code setting, initial timing setting and IP address setting.
Initial settings
Make the timer setting and DNS setting.
Open settings
Make the open settings.
Routing information
Set the router relay function, sub-net mask pattern, default router IP address, etc.
MNET/10 routing information
Set the MNET/10 routing system, net mask pattern, etc.
FTP Parameters
Set the login name, password, command input watchdog timer, CPU watchdog timer, etc.
E-mail settings
General setting
Set the password, mail address, etc.
Mail server name
Set the SMTP server name and
IP address.
Mail receive setting
Set the POP server name and IP address.
Send mail address setting
Set the mail address.
News setting
Set the condition device, monitor condition, etc.
Interrupt settings
Set the detection method, interrupt condition, interrupt (SI) No., Etc.
5 – 24
MITSUBISHI ELECTRIC
Parameters Network Parameters
Network parameter items of the QnA series
MELSECNET/10 Ethernet
Network type
Specify the MELSECNET (II, /10).
Starting I/O No.
Set the first I/O No.
Network No.
Set the network No.
Total stations
Set the total number of (slave) stations.
Network range type (Common parameters)
I/O Master station specification
Set the I/O master station on the LX/LY setting screen.
Reserved station specification
Specify the reserved station.
Equal assignment
Set when assigning the link device points of the specified stations equally.
Network type
Specify Ethernet.
Starting I/O No.
Set the first I/O No.
Network No.
Set the network No.
Group No.
Set the group No.
Station No.
Set the station number.
IP Address Settings
Set the IP address of the Ethernet unit.
MNET/10 routing information
Set the MNET/10 routing system, net mask pattern, etc.
FTP Parameters
Set the login name, password, command input watchdog timer, CPU watchdog timer, etc.
Identical point assignment
Set the same points according to the preset total number of stations.
Supplementary settings
Make the transient, low-speed cyclic and other settings.
Station inherent parameters
Set the station inherent parameters.
Refresh parameters
Set the refresh parameters.
Fig. 5-23:
Network parameter items of the QnA series (1)
Routing information
Set the router relay function, sub-net mask pattern, default router IP address, etc.
GX IEC Developer Reference Manual 5 – 25
Network Parameters Parameters
NOTE
MELSECNET/MINI CC-Link
Unit count
Set the number of units. (1 to 8 units)
Model name
Set the model name of the
MELSECNET/MINI(S3) loaded.
Station count
Set the total number of remote I/O stations.
Batch refresh receive data
Set the receive data for batch refresh.
Batch refresh send data
Set the send data for batch refresh.
Retry
Set the number of retries made to the remote I/O station where a communications fault occurred.
Response
Set whether access to the master unit buffer memory is assigned to "link" priority or "CPU" priority.
Error data clear
Set whether the data of the station in communications error is cleared or held.
Abnormal station detection bit data
Set the device where the abnormal station detection data will be stored.
Abnormal communication remote
Set the device where the error code at error occurrence will be stored.
Unit count
Set the number of units. (1 to 4 units)
Operational settings
Set the parameter name and data link abnormal station.
Type
Set the master/local/standby master station, etc.
Master station data link type
Fixed to "PLC parameter auto start".
Mode
Set the mode.
All connectcount
Set the number of slave stations connected. (1 to 64 stations)
Remote input [RX]
Set the bit devices to be batch-refreshed.
Remote output [RY]
Set the bit devices to be batch-refreshed.
Remote register [Rwr]
Set the word devices to be batch-refreshed.
Remote register [Rww]
Set the word devices to be batch-refreshed.
Special relay [SB]
Set the bit devices to be batch-refreshed.
Special register [SW]
Set the bit devices to be batch-refreshed.
Retry count
Set the number of transmission retries.
Automatic reconnection station count
Set the number of stations automatically reconnected during 1 scan.
Circuit error check
Set the transmission status at occurrence of a circuit error.
STOP time operation
Set whether link is stopped or continued at STOP of the CPU.
Wait master station No.
Set the station number of the standby master station.
PLC down select
Set whether data link is continued or stopped at a stop of the CPU.
Scan mode setting
Set whether sequence scans are synchronized or not.
Delay information settings
Set the link scan interval delay time.
Station information settings
Set the station type, number of occupied stations, etc.
Fig. 5-23:
Network parameter items of the QnA series (2)
CC-Link parameters cannot be set to the Q4ARCPU.
5 – 26
MITSUBISHI ELECTRIC
Parameters Network Parameters
Network parameter items of the A series
MELSECNET (II, /10)
MELSECNET/MINI
Network type
Specify the MELSECNET (II, /10).
Starting I/O No.
Set the first I/O No.
Network No.
Set the network No.
Total stations
Set the total number of (slave) stations.
Network range type (Common parameters)
I/O Master station specification
Set the I/O master station on the LX/LY setting screen.
Reserved station specification
Specify the reserved station.
Equal assignment
Set when assigning the link device points of the specified stations equally.
Identical point assignment
Set the same points according to the preset total number of stations.
Supplementary settings
Make the transient, link start indication and other settings.
Station inherent parameters
Set the station inherent parameters.
Refresh parameters
Set the refresh parameters.
Unit count
Set the number of units. (1 to 8 units)
Model name
Set the model name of the MELSECNET/MINI(S3) loaded.
Station count
Set the total number of remote I/O stations.
Batch refresh receive data
Set the receive data for batch refresh.
Batch refresh send data
Set the send data for batch refresh.
Retry
Set the number of retries made to the remote I/O station where a communications fault occurred.
Response
Set whether access to the master unit buffer memory is assigned to "link" priority or "CPU" priority.
Error data clear
Set whether the data of the station in communications error is cleared or held.
Abnormal station detection bit data
Set the device where the abnormal station detection data will be stored.
Abnormal communication remote
Set the device where the error code at error occurrence will be stored.
Circuit error check
Set the transmission status at occurrence of a circuit error.
STOP time operation
Cannot be set for the A series.
Fig. 5-24:
Network parameter items of the A series
GX IEC Developer Reference Manual 5 – 27
Network Parameters
5.3.4
Parameters
Explanations for Network Parameter Setting Screen
The following items are related to network parameter setting.
쎲 Unit valid for other station access
This setting is made valid when there are multiple units which are used without specifying the network No. or when the network No. has not been set for access to the other station.
쎲 Read PLC data button
Reads the implementation status.
– For QnA series
Always delete the parameter file of the PLC before reading the implementation status. The parameter file is read if the parameter file exists in the PLC.
쎲 Remote I/O project
You can set up to four Ethernet modules and CC-Link modules, respectively.
쎲 MELSOFT connection on Ethernet connection (Q Series only)
This setting is used when connecting multiple MELSOFT products such as GX IEC
Developer (a maximum of 17 units) using the TCP/IP communication system.
– Setting procedure:
Ethernet
씮 Open settings 씮 Protocol (TCP) 씮 Open system (MELSOFT connection)
The screen below gives a setting example when user connections 14 to 16 are used to connect MELSOFT products, while connections 1 to 5 are used to communicate with non-MELSOFT products via a MC protocol communication, fixed-buffer communication, etc.
Used for various communications
Used to connect
MELSOFT products
Fig. 5-25:
Device Settings
NOTE
For the Q series, Read PLC data is not available for the network parameters.
5 – 28
MITSUBISHI ELECTRIC
Parameters
5.4
5.4.1
Memory Parameters
Memory Parameters
Memory Parameters (MELSEC A)
This dialogue box contains all the settings for the assignment and allocation of memory. In addition, you can also set further parameters.
Fig. 5-26:
Memory parameters of the A series
Program capacity: Allocation of MAIN program sequence memory
1 step = 2 bytes
The program checks the maximum value automatically. After compilation the memory actually required is shown in Memory capacity information.
Sub sequence: Allocation of SUB program sequence memory
1 step = 2 bytes
The program checks the maximum value automatically. After compilation the memory actually required is shown in parentheses after this entry.
Microcomputer: Allocation of memory for microcomputer programs
This option is only relevant for Sequential Function Chart programs for the PLC CPUs of the
AnN series. The memory for these programs must be allocated in steps of 2 kByte.
File register: Allocation of memory for the file registers
The available memory depends on the type of memory cassette installed.
Comment/Extended comment: Allocation of memory for the comments
Capacity for debugging: Allocation of memory for debugging
GX IEC Developer Reference Manual 5 – 29
Memory Parameters
5.4.2
Parameters
Memory Parameters (MELSEC FX)
This dialogue box contains all the settings for the assignment and allocation of memory. In addition, you can also set further parameters.
5 – 30
Fig. 5-27:
Memory parameters of the FX3U
Memory capacity: Allocation of program memory. Set the memory capacity of the PLC.
Comments capacity: Allocation of memory for the comments.
File register capacity: Allocation of memory for the file registers.
Program capacity: Allocation of sequence program memory.
Special Function Memory capacity (FX3U only): Select the special extension module/block initial value setting or positioning setting.
MITSUBISHI ELECTRIC
Parameters
5.4.3
Memory Parameters
Memory Parameters (MELSEC Q/QnA)
In addition to showing the program size parameters for the selected CPU this dialogue box is also used to define the number of file registers you wish to use.
Fig. 5-28:
Specifying program size and file registers
NOTE
File Register
If you wish to use file registers in Q/QnA series CPUs you have to define the number you wish to use here first. The Q00J CPU does not support file registers.
Capacity: Specify the number of file registers you wish to use (units: k points). The Q/QnA
CPU can handle a maximum of 1024 addresses (i.e. 1MB). However, since a few addresses are also used for making the file registers available you can only actually use a maximum of
1018 addresses. The Q00 and Q01 CPUs are fixed to 32 kPoints.
Corresponding memory: Specify the number of the drive corresponding to the external memory card you wish to use for the file registers (not available for Q00(J), Q01 CPUs).
Valid entries in the pull-down list:
IC Card A(RAM): RAM in the card in the first slot
IC Card A(ROM): ROM in the card in the first slot (QnA only)
IC Card B(RAM): RAM in the card in the second slot
IC Card B(ROM): ROM in the card in the second slot (QnA only)
File registers can not be created in the flash card ROM of a Q CPU under GX IEC Developer.
GX IEC Developer Reference Manual 5 – 31
Latch Ranges
5.5
5.5.1
Parameters
Latch Ranges
The PLC Parameter settings include a check mechanism. If a setting in the System Variables overlaps with the corresponding setting in the Latch Range, an overlap warning will be displayed. You can ignore this warning and continue or modify the settings.
Latch Ranges (MELSEC A)
This dialogue box includes all the settings available for the division and allocation of the retentive, battery-powered memory ranges. The data in these ranges is then stored in the event of a power failure or a system reset. Please note that the settings you make here have nothing to do with the Status Latch settings in the Debug menu!
5 – 32
Fig. 5-29:
The values for parameters followed by an H in parentheses
(H) must be entered in hexadecimal format.
Latch Relays / Link Relays: Device range for the memory-resident latch and link relays. The parameter values must be entered in hexadecimal format.
Timers: Device range for the 10 ms and 100 ms timers
Counters: Counter device range
Data/Link Registers: Register device range
Extended Timers: Device range for extended timers
Extended Counters: Device range for extended counters
MITSUBISHI ELECTRIC
Parameters
5.6
5.6.1
Device Settings
Device Settings
Device Settings (MELSEC Q/QnA)
This dialogue box is used to define the devices to be used in the project. You can also specify whether the latch operation is to be performed or not for the non-volatile device ranges with battery backup.
Fig. 5-30:
Device Settings
GX IEC Developer Reference Manual 5 – 33
Device Settings Parameters
The following table shows the correspondences between the devices in the A series and the
Q/QnA series:
MELSEC A Devices
Accumulators A0 and A1
Link registers B
Counters C
Data registers D0 - D8191
Special registers D9000 - D9255
Annunciators F
Hexadecimal constants H
Interrupt pointers I
Constants K
Latch relays L0 - L8191
Internal Relays M0 - M8191
Special relays M9000 - M9255
Nesting N
Pointers P
File registers R
Step relays S0 - S8191
Timers T (low-speed 100ms
)
Timer T (high-speed 10ms
)
Accumulator (retentive) timers T
Index registers V, V1, V2
, .....
Link registers W
Input relays X
Output relays Y
Index registers Z, Z1, Z2
, ...
MELSEC Q/QnA Devices
Diagnostics link registers SD718 and SD719
Diagnostics link registers SD1000 - SD1255
Diagnostics link relays SM1000 - SM1255
Accumulator timers ST
Index registers Z7, Z8, Z9 …
Index registers Z0, Z1, Z2, ...
Tab. 5-4:
Correspondences between A series and Q series devices
5 – 34
MITSUBISHI ELECTRIC
Parameters Device Settings
RAD
Input format (10 = decimal, 16 = hexadecimal)
Devices
Enter the number of devices you wish to use in your project in this column. The device types with no entry fields have a fixed range which cannot be changed by the user:
쎲 Input relays X
Q00J, Q00, Q01 = 2 K, Others = 8 K
쎲 Output relays Y
Q00J, Q00, Q01 = 2 K, Others = 8K
쎲 Diagnostics link relays SB
Q00J, Q00, Q01 = 1 K, Others = 2K
쎲 Step relays S
Q00J, Q00, Q01 = 2 K, Others = 8K
쎲 Diagnostics link registers SW
Q00J, Q00, Q01 = 1 K, Others = 2K
Maximum Input Limits
Maximum value for bit devices: 32K address points
Maximum number of all bit devices: 64K address points
Maximum total number of devices: 29K words
Number of bits per word/kWord
1 word = 16 bits
1Kword = 1,024 words = 16,384 bits
Number of bits per address
X, Y, M, L, B, F, SB, V, S : 1 address = 1 bit
D, W, SW: 1 address = 16 bits = 1 word
T, ST, C: 1 address = 18 bits = 1 word + 2 bits
GX IEC Developer Reference Manual 5 – 35
Device Settings Parameters
5.6.2
NOTE
Devices in a Redundant System
A feature called Tracking makes it possible, that in a redundant system devices have the same values on both PLCs. This is vital for consistent continuation after a system switch. The following devices are synchronized (tracked) between the Control and Standby systems automatically at every scan by default.
Device
Input
Output
Internal Relay
Latch Relay
Step Relay
Edge Relay
Link Relay
Timer
Counter
Data Register
Link Register
Index Register
Default tracking range
X0 to X1FFF
Y0 to Y1FFF
M0 to M8191
L0 to L8191
S0 to S8191
V0 to V2047
B0 to B1FFF
T0 to T2047
C0 to C1023
D0 to D 12287
W0 to W1FFF
Z0 to Z15
Tab. 5-5:
List of devices being synchronized in a redundant system
The tracking settings can also be set manually (for max 100 kW devices) in the Parameters.
This may be helpful to
쎲 reduce the number of tracked devices, reducing the delay in the scan time caused by the tracking, or
쎲 track devices that are not tracked by default (e.g. File Register).
Modifying device values on the Standby system does not have the same effect as on a regular system, since any modification can be overwritten with the device value from the Control system by the tracking functionality. Therefore modifying device values on the Standby system is not supported by default.
This affects the following functionalities:
쎲 Monitoring in a POU body
쎲 Monitoring in the EDM
쎲 The Online
Modify Variable Value functionality
쎲 The EDM’s Write to PLC functionality
쎲 The Device Edit’s Write to PLC functionality
쎲 Monitoring in the Buffer Memory Batch Monitor
When attempting to execute any of these operations on the Standby system, an error message will be displayed.
It is possible to enable modifying devices on the Standby system on the Extras
씮 Options
씮 Redundancy option page. Please see sec. 2.9.4 for details.
5 – 36
MITSUBISHI ELECTRIC
Parameters
5.7
Boot Settings (MELSEC Q/QnA (except Q25SS (SX Controller))
Boot Settings (MELSEC Q/QnA (except Q25SS
(SX Controller))
In the Boot settings PLC behaviour on booting are specified. Here a system area can be created to speed up monitoring or for Multiple Block Online Change (MBOC).
Fig. 5-31:
Boot settings (except Q00(J), Q01 CPU),
Clear PLC RAM: Clears the program memory before booting, if selected.
System area assumed steps: Select size of system area for high-speed monitoring from other stations. Range: 0 – 15 kSteps. Only available, if Clear program memory is selected.
Boot file setting: Set the boot-run file, etc.
Fig. 5-32:
Boot setting (Q00(J), Q01 CPU)
NOTE
Do boot from Standard ROM: Do boot from Standard RAM, if selected.
See sec. 8.6.1 for Boot Settings concerning the Intelligent Parameter File of the Q series.
GX IEC Developer Reference Manual 5 – 37
PLC System (FX2N)
5.8
Parameters
PLC System (FX2N)
In this dialogue box the communication settings between computer link and protocol type is enabled, disabled, and setup. The settings are stored in the project database.
5 – 38
Fig. 5-33:
PLC system settings
Operate communication setting: Enables or disables the use of communication settings.
Protocol: Select the protocol for communication. Only available, if Operate communication
setting is selected.
Data length: Select the data length for communication. Only available, if Operate communi-
cation setting is selected.
Parity: Select the parity for communication. Only available, if Operate communication
setting is selected.
Stop bit: Select the number of stop bits for communication. Only available, if Operate communi-
cation setting is selected.
Baud rate: Select the baud rate for communication. Only available, if Operate communication
setting is selected.
Header: Enables or disables the use of a header in the transmission. Only available, if
Operate communication setting is selected.
Terminator: Enables or disables the use of a terminator in the transmission. Only available, if
Operate communication setting is selected.
Control line: Use handshaking recognized by the Non procedural protocol. Only available, if Operate communication setting and Non procedural protocol are selected.
H/W type: Select the hardware type for the transmission. Only available, if Operate communi-
cation setting is selected.
Control mode: Indication of control mode.
MITSUBISHI ELECTRIC
Parameters PLC System (FX2N)
Sum check: Enables or disables the sum check for the transmission using Dedicated
protocol. Only available, if Operate communication setting and Dedicated protocol are selected.
Transmission control procedure: Select the format for Dedicated protocol. Only available, if Operate communication setting and Dedicated protocol are selected.
Station number setting: Specify a station number to use within networks. Only available, if
Operate communication setting is selected.
Time out judge time: Specify a time when to judge a time out of the transmission. Only available, if Operate communication setting is selected.
GX IEC Developer Reference Manual 5 – 39
I/O Configuration
5.9
5.9.1
Parameters
I/O Configuration
I/O Configuration (MELSEC A)
All the modules, their slot numbers and I/O address number ranges are entered in this dialogue box. A PLC system can consist of up to 8 base units with 8 slots each, thus providing up to a maximum of 64 slot numbers.
Entering the configuration data is particularly important for:
쎲 AnA and AnU systems.With these systems certain commands for specific special function modules can only be executed if the configuration has been explicitly defined.
쎲 Systems for which address ranges different from the current configuration need to be defined to reserve addresses for future expansions.
5 – 40
Fig. 5-34:
Input and output configuration
I/O Slot: Number of the base unit slot in which the module is installed
I/O Type: Module type: Input, Output or Special Function Module
I/O Range: Number of addresses allocated in the base unit
Mode name: List of the MITSUBISHI modules that can be used. Depends on the settings made in I/O Type and I/O Range.
MITSUBISHI ELECTRIC
Parameters
5.9.2
I/O Configuration
I/O Configuration (MELSEC A2C)
The A2C is configured in MINI NET mode. You can install a maximum of 14 stations in the A2C network. The station numbers to be allocated depend on the address numbers of the modules used in the configuration.
Fig. 5-35:
Input and output configuration
Remote I/O setting for A2C PLC
Total number of remote stations (1–64): Set the occupied slot count.
Online Mode The Online Mode parameter defines the CPUs operating mode.
Setting of each station
Start station No.: Starting address of the station. The calculation of the number must be performed by the user. The first address is always station number 1. For example, you must add 4 station numbers for each module occupying 32 addresses; the starting address for module 2 would thus be 5.
Protocol
MINIstandard: MINI NET protocol, normally used in most situations.
Non procedural: If you are using the AJ35PTF RS-232 module select the non procedural protocol to transfer freely-defined protocols (texts).
GX IEC Developer Reference Manual 5 – 41
I/O Configuration
5.9.3
Parameters
I/O Configuration (MELSEC QnA)
This dialogue box is used to enter all the modules and extension units installed in the system.
5 – 42
Fig. 5-36:
Input and output configuration
I/O Assignment
Slot List: All slots (max. 64)
Slot: Selected slot
Type: Input module, output module, special function module or spare slot
Points: Number of addresses occupied by the slot
StartXY: Starting address of the module in units of 16 addresses
Model name: List of supported MITSUBISHI modules
Standard setting
Extension List: 1 base unit and up to a maximum of 7 extension units
Base model name: Designation of the base unit
Power model name: Designation of the power supply
Extension cable: Designation of the extension cable
MITSUBISHI ELECTRIC
Parameters
5.9.4
I/O Configuration
I/O Configuration (MELSEC Q)
This dialogue box is used to enter all the modules and extension units installed in the system.
Fig. 5-37:
Input and output configuration
I/O Assignment
Slot List: All slots (max. 64)
Slot: Selected slot
Type: Input module, output module, special function module or spare slot
Points: Number of addresses occupied by the slot
StartXY: Starting address of the module in units of 16 addresses
Model name: List of supported MITSUBISHI modules
Standard setting
Extension List: 1 base unit and up to a maximum of 7 extension units
Base model name: Designation of the base unit
Power model name: Designation of the power supply
Extension cable: Designation of the extension cable
GX IEC Developer Reference Manual 5 – 43
I/O Configuration
Switch setting
This button opens the following dialogue:
Parameters
Fig. 5-38:
Switch settings for Intelligent Function Modules
Switch 1 – 5: Settings for switching operations. Device range: 0000h – FFFFh.
5 – 44
MITSUBISHI ELECTRIC
Parameters
Detailed setting
This button opens the following dialogue:
I/O Configuration
Fig. 5-39:
Detailed settings for Intelligent Function Modules
Error time output mode: Select whether to clear or hold the output value in case of an error.
H/W error time PLC operation mode: Select whether to stop or continue the operation in case of an error.
I/O response time: Select the response time after which the I/O values have reached a valid value.
Control PLC: For Multiple PLC operation (see section 5.14). Assign a selected control PLC
from the drop down list to the selected Intelligent Function Module. The control PLC stores the program to control the Intelligent Function Module.
GX IEC Developer Reference Manual 5 – 45
MELSECNET / Ethernet
5.10
5.10.1
Parameters
MELSECNET / Ethernet
The MELSECNET/Ethernet settings define the hardware, communications addresses and paths in a network. The dialogues differ depending on the selected CPU module. The FX family
CPUs do not support network communications. For details refer to the manuals of the network modules.
A series
GX IEC Developer supports MELSECNET/10, MELSECNET (II) and MELSECNET/MINI connections to the AnU CPU and A2US CPU modules.
MELSECNET/10, MELSECNET (II)
5 – 46
Fig. 5-40:
MELSECNET parameters
Module No. 1...4: Here you select the connection type for the network module.
Network type: Select the desired network type.
Start I/O No.: Enter the first I/O number for the network module in hexadecimal format.
Network No.: Enter the network number for MELSECNET/10.
Total stations: Enter the total number of stations.
Group No.: Enter the group number.
Station No.: Enter the station number.
Network range assignment: Opens a dialogue to enter and edit the network range assignment.
Station inherent parameters: Opens a dialogue to enter and edit the station inherent parameters.
Refresh parameters: Opens a dialogue to enter and edit the refresh parameters of the network module for the MELSEC network.
MITSUBISHI ELECTRIC
Parameters
5.10.2
MELSECNET / Ethernet
QnA series
GX IEC Developer supports MELSECNET/10, MELSECNET (II), and Ethernet connections to the QnA CPU module.
Restrictions:
쎲 The total number of network modules (MELSECNET modules + Ethernet modules) must not exceed four.
쎲 The communication via Ethernet to the QnA series is fixed to the binary protocol.
쎲 The communication via a Computer Link module to the QnA series is fixed to the format 1.
쎲 The communication via Ethernet and MELSECNET (II) to the QnA series is not supported.
MELSECNET/10, MELSECNET (II)
Fig. 5-41:
Network parameters
Module No. 1...4: Here you select the connection type for the network module.
Network type: Select the desired network type.
Start I/O No.: Enter the first I/O number for the network module in hexadecimal format.
Network No.: Enter the network number for MELSECNET/10.
Total stations: Enter the total number of stations.
Group No.: Enter the group number.
Station No.: Enter the station number.
Network range assignment: Opens a dialogue to enter and edit the network range assignment.
Station inherent parameters: Opens a dialogue to enter and edit the station inherent parameters.
Refresh parameters: Opens a dialogue to enter and edit the refresh parameters of the network module for the MELSEC network.
GX IEC Developer Reference Manual 5 – 47
MELSECNET / Ethernet Parameters
Stand by station compatible module: Opens a dialogue to enter the standby station compatible module.
Remote station compatible module: Opens a dialogue to enter the remote station compatible module.
Ethernet Settings
5 – 48
Fig. 5-42:
Ethernet settings
Module No. 1...4: Here you select the connection type for the network module.
Network type: Select the desired network type.
Start I/O No.: Enter the first I/O number for the network module in hexadecimal format.
Network No.: Enter the network number for Ethernet.
Total stations: Enter the total number of stations.
Group No.: Enter the group number.
Station No.: Enter the station number.
IP address DEC: Opens a dialogue to enter the IP address in decimal coding. Each part may contain a value from 0 – 255.
Station No. <-> IP information: Opens a dialogue to enter and edit system for the relation between station No. and IP information.
FTP parameters: Opens a dialogue to enter and edit the FTP parameters.
Router relays parameters: Opens a dialogue to enter and edit router relay parameters.
After the Ethernet settings have been set up successfully the modules will be sorted according to their first I/O numbers.
MITSUBISHI ELECTRIC
Parameters
NOTES
MELSECNET / Ethernet
The connection to the PLC via Ethernet is only supported for the AJ71QE71/A1SJ71QE71 from version B or higher and the QnA or QnAS CPU. The product version is printed on the device label. For details refer to the hardware manual of the device.
Do not apply a Windows Forced Close Operation (CTRL + ALT + DEL) during the communication between GX IEC Developer and the PLC or an communication error will occur when starting GX IEC Developer the next time. In this case restart Microsoft Windows.
GX IEC Developer Reference Manual 5 – 49
MELSECNET / Ethernet
5.10.3
Parameters
Q series
GX IEC Developer supports MELSECNET/H, MELSECNET/10, Ethernet and CC-Link connections to the Q CPU module.
MELSECNET/H / MELSECNET/10 parameters
5 – 50
Fig. 5-43:
MELSECNET/H / MELSECNET/10 parameters
Module No. 1...4: Here you select the connection type for the network module.
Network type: Select the desired network type.
Start I/O No.: Range: 0 – FFF. Enter the starting I/O number for the network module in hexadecimal format. The starting I/O number must be a multiple of 16 (10h). The starting I/O numbers must not overlap even with defined Ethernet modules and keep a gap of at least 20h.
Network No.: Range: 1 – 239. Enter the network number. The network number must not overlap with other defined modules.
Total stations: Enter the total number of stations.
Group No.: Range: 0 – 32. Enter the group number.
Station No.: Enter the station number.
Mode: Select the desired mode.
Network range assignment: Opens a dialogue to enter and edit the network range assignment.
Refresh parameters: Opens a dialogue to enter and edit the refresh parameters of the network module for the MELSEC network.
Interrupt settings: Opens a dialogue to enter and edit the interrupt settings for the selected module (not for Q00(J), Q01).
MITSUBISHI ELECTRIC
Parameters
Interrupt settings (not for Q00(J), Q01)
In this dialogue you edit the MELSECNET interrupt settings.
MELSECNET / Ethernet
Fig. 5-44:
MELSECNET interrupt settings
Refresh parameters
In this dialogue you edit the refresh parameters for a selected Q module.
Fig. 5-45:
Refresh parameters
GX IEC Developer Reference Manual 5 – 51
MELSECNET / Ethernet
Common parameters
Parameters
5 – 52
Fig. 5-46:
Common network parameters
I/O Master station specification: Using Switch screens to choose LX/LY settings enables the I/O master station to be specified. To set the I/O master station, specify the station number with the cursor and click I/O Master station specification.
Reserved station specification: Specify the reserved station No. and click this button.
Equal assignment: Used to assign the link device points of all stations equally. The first and last stations can be set within the number of stations between the first and last equally assigned station numbers (total number of link stations - (first station number - 1)).
Identical point assignment: Used to make simple assignment with the same points according to the preset total number of stations.
Supplementary settings: Used to set the constant scan, max. number of reconnected stations during 1 scan, multiple transmission, communications error setting and transient setting.
Clear: Used to default the parameter settings.
Check: Used to check the preset parameter data.
End setup: Clicking this button at the end of data setting returns to the network setting screen.
MITSUBISHI ELECTRIC
Parameters
Ethernet parameters
MELSECNET / Ethernet
Fig. 5-47:
Ethernet parameters
Module No.1...4: Here you select the connection type for the network module.
Network type: Select the desired network type from the drop-down list. Select “None” to clear the parameter set.
Start I/O No.: Range: 0 – FFF. Enter the starting I/O number for the network module in hexadecimal format. The starting I/O number must be a multiple of 16 (10h). The starting I/O numbers must not overlap even with defined MELSECNET modules and keep a gap of at least
20h.
Network No.: Range: 1 – 239. Enter the network number. The network number must not overlap with other defined modules.
Total stations: Enter the total number of stations.
Group No.: Range: 0 – 32. Enter the group number.
Station No.: Range: 0 – 64. Enter the station number.
Operational settings: Opens a dialogue to enter the Ethernet operations like the IP address in decimal coding.
Initial settings: Opens a dialogue to enter the Timer and DNS settings.
Open settings: Opens a dialogue to enter settings when connecting multiple MELSOFT products such as GX IEC Developer (a maximum of 17 units) using the TCP/IP communication
system. See also section 5.3.4.
Router relay settings: Opens a dialogue to enter the router relay settings.
Station No. <-> IP information: Opens a dialogue to enter and edit system for the relation between station No. and IP information.
FTP parameters: Opens a dialogue to enter and edit the FTP parameters.
Router relays parameters: Opens a dialogue to enter and edit router relay parameters.
E-mail settings: Opens a dialogue to enter the settings for sending and receiving e-mails.
Interrupt settings: Opens a dialogue to edit the Ethernet interrupt settings (not for Q00(J),
Q01).
GX IEC Developer Reference Manual 5 – 53
MELSECNET / Ethernet
5.10.4
Parameters
Qn(H) series and QnU(D)(E)(H) series
The CC-Link IE Controller Network is supported only by Qn(H) series and QnU(D)(E)(H) series PLCs.
CC IE Control (Control station) and CC IE Control (Normal station) parameters
5 – 54
Fig. 5-48:
CC IE Control parameters
Module No. 1...4: Here you select the connection type for the network module.
Network type: Select the desired network type.
Start I/O No.: Range: 0 – FFF. Enter the starting I/O number for the network module in hexadecimal format. The starting I/O number must be a multiple of 16 (10h). The starting I/O numbers must not overlap even with defined Ethernet modules and keep a gap of at least 20h.
Network No.: Range: 1 – 239. Enter the network number. The network number must not overlap with other defined modules.
Total stations: Enter the total number of stations.
Group No.: Range: 0 – 32. Enter the group number.
Station No.: Enter the station number.
Mode: Select the desired mode.
Network range assignment: Opens a dialogue to enter and edit the network range assignment.
Refresh parameters: Opens a dialogue to enter and edit the refresh parameters of the network module for the MELSEC network.
Interrupt settings: Opens a dialogue to enter and edit the interrupt settings for the selected module.
Specify station No. by parameter / Specify station No. by program: Select the desired setting.
MITSUBISHI ELECTRIC
Parameters
Interrupt settings (not for Q00(J), Q01)
In this dialogue you edit the MELSECNET interrupt settings.
MELSECNET / Ethernet
Fig. 5-49:
CC IE Control interrupt settings
Refresh parameters
In this dialogue you edit the refresh parameters for a selected Qn(H) or QnU(D)(E)(H) module.
Fig. 5-50:
CC IE Control refresh parameters
GX IEC Developer Reference Manual 5 – 55
MELSECNET / Ethernet
Common parameters
Parameters
Fig. 5-51:
CC IE Control common network parameters
I/O Master station specification: Using Switch screens to choose LX/LY settings enables the I/O master station to be specified. To set the I/O master station, specify the station number with the cursor and click I/O Master station specification.
Reserved station specification: Specify the reserved station No. and click this button.
Equal assignment: Used to assign the link device points of all stations equally. The first and last stations can be set within the number of stations between the first and last equally assigned station numbers (total number of link stations - (first station number - 1)).
Identical point assignment: Used to make simple assignment with the same points according to the preset total number of stations.
Help - Network setting: Clicking this button opens a dialogue that presents help for the network settings.
Fig. 5-52:
Help - Network setting
5 – 56
MITSUBISHI ELECTRIC
Parameters MELSECNET / Ethernet
Shared group setting: Used to set shared group selection for setting check/edit.
Fig. 5-53:
CC IE Control shared group
Supplementary settings: Used to set the constant scan, max. number of reconnected stations during 1 scan, multiple transmission, communications error setting and transient setting.
Station inherent parameters: Used to change the network unit storage locations of the link devices assigned to each station in the common parameters.
Clear: Used to default the parameter settings.
Check: Used to check the preset parameter data.
End setup: Clicking this button at the end of data setting returns to the network setting screen.
GX IEC Developer Reference Manual 5 – 57
PLC Setup
5.11
5.11.1
PLC Setup
PLC Setup (MELSEC A)
Parameters
5 – 58
Fig. 5-54:
PLC Setup
RUN-PAUSE Contacts: These fields are used for entering the inputs (X) used for controlling the PLC’s operating mode.
Run
The PLC is set to RUN mode as soon as this input is on.
Pause When this input is on the PLC is switched to PAUSE mode.
Relay M9040 must be set for this to be possible.
System interrupt setting: Set the range of the counter used in an interrupt program.
Output mode at STOP to RUN: Behaviour of the PLC CPU after a system stop and restart of the process.
Previous State
Resume process
Recalculate State
Recalculate
Data communications request batch processing: Set whether the transient communications request is processed or not in the END processing of its scan.
MITSUBISHI ELECTRIC
Parameters
5.11.2
PLC Setup (MELSEC Q/QnA)
PLC Setup
Fig. 5-55:
PLC RAS
WDT Setting: Setting for the watchdog timer.
Range: 10 - 2,000 ms in units of 10 ms
(only for Q25SS (SX Controller)
Range: 10 - 5,000 ms in units of 10 ms)
Error Check: Enables you to activate/deactivate the following error checking functions:
쎲 Battery
쎲 Fuse
쎲 I/O modules
Operation Mode at Error: These options enable you to specify whether the CPU is to pause or continue working when the following error conditions are registered:
쎲 Calculation error
쎲 Extended Ins
쎲 Fuse blown
쎲 I/O unit compare error
쎲 Special function unit access error
쎲 IC card access error (not for Q00(J), Q01)
쎲 IC card operation error (not for Q00(J), Q01)
GX IEC Developer Reference Manual 5 – 59
PLC Setup Parameters
Constant Scanning: Enter the constant scan cycle period here.
Range: 5 - 2,000 ms in units of 5 ms
Number of free slots: Enter the number of addresses occupied by a free slot in this field.
Range: 0 - 1024 in units of 16
Annunciator display mode: Set the display mode established when the annunciator has turned on.
Breakdown history: Set the storage target of the CPU's breakdown history.
5 – 60
Fig. 5-56:
PLC system
Timer limit setting: Used to set the intervals for the high-speed and low-speed timers. The timers will then act as high-speed or low-speed timers when they are activated by the appropriate instructions in the PLC program.
Low-speed timer instructions: TIMER (IEC editor), OUT (MELSEC editor)
High-speed timer instructions: TIMER_H (IEC editor), OUT_H (MELSEC editor)
Low-speed timer range: 10 - 1,000ms in units of 10ms
High-speed timer range: 1 - 100ms in units of 1ms
RUN-PAUSE Contacts: Enter the inputs to be used to control the operating mode of the
PLC here.
Range: X0 - X1FFF (QnA series)
The PLC will be switched to RUN or PAUSE mode as soon as the corresponding input is set.
When using the PAUSE contact the diagnostics link relay SM206 (QnA series) must also be set.
Remote reset: Set enable/disable of remote reset operation.
MITSUBISHI ELECTRIC
Parameters PLC Setup
Output mode at STOP to RUN: Behaviour of the PLC CPU after a system stop and restart of the process.
Previous State
Recalculate State
Resume process
Recalculate
Common pointer: Set the first No. of the common pointers.
Number of empty slots: Set the number of empty slots.
System interrupt setting: These fields enable you to specify the counters you wish to allocate to the system interrupt signals. A total of 32 interrupts are available (I0 - I31).
1st Int Counter: The first interrupt counter can be an address from the following counter range:
C0 - [sum of all counters minus 48]
Example:
Assuming you have set 1K of addresses for the counters in the Device Settings dialogue box you have 1,024 counter addresses available (C0 - C1023).
A possible entry for the first interrupt counter would thus be:
C0 - 1024 minus 48, which gives you
C0 - C976
I28 / I29 / I30 / I31 Const Interval: You can set constant interrupt intervals for interrupts I28 - I31.
Range: 5 - 1,000ms in units of 5ms
(only for Q25SS (SX Controller)
Range: 100 - 1,000 ms in units of 10 ms)
GX IEC Developer Reference Manual 5 – 61
CC-Link (MELSEC Q/QnA)
5.12
Parameters
CC-Link (MELSEC Q/QnA)
The CC-Link settings define the hardware, communications addresses and paths in a network. For details refer to the manuals of the network modules.
Fig. 5-57:
CC-Link settings
Number of boards within modules: Before you can edit the CC-Link settings you have to select the number of CC-Link boards from the drop-down list. Up to 8 boards can be edited in individual dialogue boxes. Each dialogue box can be selected via tabs.
Fig. 5-58:
Drop-down list for selecting the number of
CC-Link boards
5 – 62
Start I/O No.: Enter the start I/O number in multiples of 10h. The start I/O number of the individual boards must not overlap. Value Range: 0000 – 0FE0.
Operational setting: Enter the parameter name and data link abnormal station.
Type: Enter the master/local/standby master station, etc.
MITSUBISHI ELECTRIC
Parameters CC-Link (MELSEC Q/QnA)
Master station data link type: Fixed to "PLC parameter auto start".
Mode: Set the mode.
All connect count: Enter the number of slave stations connected. (1 to 64 stations)
Remote input [RX]: Enter the bit devices to be batch-refreshed.
Remote output [RY]: Enter the bit devices to be batch-refreshed.
Remote register [Rwr]: Enter the word devices to be batch-refreshed.
Remote register [Rww]: Enter the word devices to be batch-refreshed.
Special relay [SB]: Enter the word devices to be batch-refreshed.
Special register [SW]: Enter the word devices to be batch-refreshed.
Retry count: Enter the number of transmission retries.
Automatic reconnection station count: Enter the number of stations automatically reconnected during 1 scan.
Standby master station No.: Enter the station number of the standby master station.
PLC down select: Select Stop (default) or Continue for CC-Link communications in case the
PLC has stopped.
Scan mode setting: Enter whether sequence scans are synchronized or not. Select Asyn-
chronous (default) or Synchronous scan mode.
Delay information settings: Enter the link scan interval delay time.
Station information settings: This button opens the CC-Link station information dialogue
(see below). Enter the station type, number of occupied stations, etc.
Remote device station initial setting: This button opens the Remote device station initial
setting dialogue (see below). Enter the corresponding station number and procedure registration (operation, execution and other conditions).
Interrupt settings: Opens the Interrupt settings dialogue (see below) to edit the Ethernet interrupt settings (not for Q00(J), Q01).
GX IEC Developer Reference Manual 5 – 63
CC-Link (MELSEC Q/QnA)
5.12.1
Parameters
CC-Link station information
In the CC-Link setting dialogue click on the Station information button to open the following dialogue.
Fig. 5-59:
CC-Link station information
The total number of CC-Link stations you specified in the CC-Link setting dialogue in the field
All connect count are listed. Click on any station number to select a station entry and edit it via the drop-down lists and entry fields on top.
Station type: Select the station type.
Exclusive station count: Select a number for the exclusive station.
Reserve/invalid station select: Enter the station status.
Intelligent buffer select: Enter the buffer sizes. Value ranges: 0 – 4096
Default: This button resets the selected station number to default values.
Check: This button checks the settings of the selected station number for errors.
5 – 64
MITSUBISHI ELECTRIC
Parameters
5.12.2
CC-Link (MELSEC Q/QnA)
Remote device station initial setting
In the CC-Link setting dialogue click on the Initial settings button to open the following dialogue.
Fig. 5-60:
Initial settings of remote device stations
Target number: Lists the number of the registered target station.
Target station No.: Enter a number for the target station to be registered or edited. Value range: 1– 64.
Regist procedure: This button opens the procedure registration dialogue (see below) for a target station either selected from the list or entered in the Register target station field.
Clear: This button deletes all entered data.
Check: This button checks a selected entry for setting errors.
GX IEC Developer Reference Manual 5 – 65
CC-Link (MELSEC Q/QnA) Parameters
Procedure registration dialogue
In the Remote device station initial setting dialogue click on the Regist procedure button to open the following dialogue.
5 – 66
Fig. 5-61:
Procedure registration for modules
The procedures for the target station are listed. Click on any procedure entry to select and edit it via the drop-down lists and entry fields on top.
Execute flag: Select to set the execute flag.
Operational condition: Select Same as prev. set or Set new.
Condition device: Select a condition device from the drop-down list.
Device number: Enter address of the condition device.
Execute condition: Select from drop-down list.
Write device: Select from drop-down list.
Device number: Enter address of the write device.
Write data: Select ON or OFF from the drop-down list.
Default: This button resets a selected entry to default values.
Check: This button checks a selected entry for setting errors.
MITSUBISHI ELECTRIC
Parameters
5.12.3
CC-Link (MELSEC Q/QnA)
Interrupt settings
In the CC-Link setting dialogue click on the Interrupt settings button to open the following dialogue.
Fig. 5-62:
Interrupt settings
The interrupt settings for the selected CC-Link board are listed. Click on any entry to select and edit it via the drop-down lists and entry fields on top.
Device code: Select a device code from the drop-down list.
Device No.: Enter a device number. Value range: 0000 – 07FF.
Detection method: Select a detection method from the drop-down list.
Interrupt condition: Select an interrupt condition from the drop-down list.
Word device: Setting value: Enter a setting value for word devices.
Value range: 0 – 65535
Board No.: Enter the board number.
Interrupt (SI) No.: Enter value. Value range: 0 – 15.
Clear: This button deletes all entered data.
Check: This button checks a selected entry for setting errors.
GX IEC Developer Reference Manual 5 – 67
MELSECNET/MINI
5.13
5.13.1
Parameters
MELSECNET/MINI
MELSECNET/MINI (MELSEC A/QnA)
The settings for the MiniNet are made in the table. The line above the buttons displays either a note on correct entry or an error message, depending on the cell selected in the table.
5 – 68
Fig. 5-63:
MELSECNET/MINI settings
Start I/O No.: Enter the first I/O number for the network module in hexadecimal format.
Model name: Selection of the network type: MiniNet or MiniNet-S3
Batch refresh receive data: Definition of the operands for refreshing receive data. The following operands are valid: X, M, L, S, B, T, C, D, W, R
Batch refresh send data: Definition of the operands for refreshing send data. The following operands are valid: X, M, L, S, B, T, C, D, W, R
Retry: Enter the number of communications error retries within the range of 0–32.
Response: Select which device has FROM/TO command buffer memory access priority rights, the link or the PLC.
Error data clear: The status of data transmission in the event of a communication error.
The following entries are possible:
TEST Output of a test string
OFF Transmission of a 00 string to the remote I/O station
HOLD Sends data to the remote I/O station shortly before communication
Abnormal station detection bit data: Enter the M, L, S, B, T, C, D, W, or R device name.
Abnormal communication remote: Enter the T, C, D, W, or R device name.
MITSUBISHI ELECTRIC
Parameters MELSECNET/MINI
Circuit error check: Select either line error check test memo, OFF data or hold data.
STOP time operation: Specifies the operating status of the MELSECNET/MINI when the
PLC was stopped:
RESUME: MELSECNET/MINI continues operation
PAUSE: MELSECNET/MINI suspends operation
Valid only for QnA.
GX IEC Developer Reference Manual 5 – 69
Multiple PLC settings (Q series only, except Q00(J))
5.14
Parameters
Multiple PLC settings (Q series only, except Q00(J))
Up to four Q series CPUs can be combined on one base unit to increase the overall PLC performance by sharing different controller tasks to different CPUs.
5 – 70
Fig. 5-64:
Multiple PLC settings
No. of PLC
Clicking the Default button in I/O assignment keeps the multiple PLC setting unchanged.
When the set number of PLCs is one, a multiple CPU system configuration is not set.
Out of group input/output settings
When the modules are not grouped, they are all put under the control PLC of the PLC No. 1.
OPERATION ERROR appears if access is made to any module outside the groups.
Refresh settings
The maximum input range of each module is 0 to 2048 points.
Set the total number of all modules to within 4096 points.
Diversion of multiple PLC parameter button
Specify the project to be diverted from the Open Project screen. Setting the source project shows the multiple PLC parameter diversion dialogue box. Confirm the message and execute.
MITSUBISHI ELECTRIC
Parameters
5.15
Serial (Q00 and Q01 only)
Serial (Q00 and Q01 only)
The dialogue Internal serial communication is used to enable, disable, and setup the communications with the PLC as Computer Link Module via the serial port. The settings are stored in the project database.
Fig. 5-65:
Internal serial communication settings for computer link connections
Use serial communication: Enables or disables the use of the serial communication settings for Computer Link communications. Default: Disabled.
Baud Rate: Selects a baud rate. Default: 19200. Setting range: 9600 – 115200.
Sum Check: Enables or disables a sum check for the transmission. Default: Enabled.
Transmission wait time: Selects a wait time for the transmission.
Default: 0. Setting range: 0 – 150.
RUN write setting: Enables or disables online changes during the transmission.
Default: Disabled.
GX IEC Developer Reference Manual 5 – 71
CPU Type Selection Parameters
5.16
NOTE
CPU Type Selection
The CPU type can be changed by selecting the command Change PLC Type in the Project menu or by clicking on the icon.
In the dialogbox Change PLC Type you can select a PLC series and a PLC type. To change the CPU type, open the list box, select the new CPU type and confirm with OK.
When you change the CPU GX IEC Developer deletes the old libraries and regenerates the
Standard and Manufacturer libraries for the new PLC type. This process can take a while as all the instructions for the new CPU must be integrated in the libraries.
The following table lists all supported CPU types.
PLC Series
AnN
AnS
AnSH
AnA / AnU
A2AS / A2US
FX
QnA
Q
QnPH
QnPRH
CPU Type
A1N, A2C, A2N, A3N
A1S, A1S-S1, A2S, A2S-S1
A1SH / A1SJH, A2SH, A2SH-S1
A2A, A2A-S1, A3A, A2U, A2U-S1, A3U
A2AS, A2AS-S1, A2US, A2US-S1, A2AS-S30, A2US-S30,
A2AS-S60, A2US-S60, A2USH-S1
FX / FX2, FX0 / FX0S, FX0N, FX1S, FX1N, FX2N / FX2NC,
FXU / FX2U / FX2C, FX3U
Q2A(H), Q2AS(H), Q2A(H)-S1, Q2AS(H)-S1, Q3A,
Q4A, Q4AR (from version 0012B)
Q00, Q00J, Q01, Q02(H), Q06H, Q12H, Q25H,
Q25SS (SX Controller), Q Remote I/O,
Q02U, Q03UD, Q03UDE, Q04UDH, Q04UDEH, Q06UDH, Q06UDEH,
Q13UDH, Q13UDEH, Q26UDH, Q26UDEH
Q12PH, Q25PH
Q12PRH, Q25PRH
Tab. 5-6:
Supported CPU-types
5 – 72
MITSUBISHI ELECTRIC
Programming
6 Programming
6.1
The Structure of GX IEC Developer Programs
The Structure of GX IEC Developer Programs
Data Unit Types
DUT 1
DUT 2
DUT 3
Global Variables
VAR_GLOBAL
VAR_GLOBAL
VAR_GLOBAL
POUs
POU 1
Program
POU 2
Function
POU 3
Program
POU 4
Program
POU 5
Function block
POU 6
Program
POU 7
Program
POU 8
Function
Fig. 6-1:
PLC program structure
Task 1
POU 1
Program
POU 3
Program
POU 4
Program
Task 2
POU 6
Program
POU 7
Program
6.2
NOTE
NOTE
Tasks
The Task Pool is the ‘control centre’ for the execution of your programs. You must define at least one task for the project in the Task Pool. In turn, each task contains one or more PRG
(program) type POUs. Each POU can only be defined once in any one task in the Task Pool.
The tasks in the Task Pool are polled cyclically.
You cannot directly manage either function blocks or their instances in tasks.
The execution of tasks is controlled by the following three parameters:
쎲 Event
쎲 Interval
쎲 Priority
All tasks are either event-triggered or interval-triggered.
In order to address the SUB memory range with the A3 CPUs you must create a special task called MELSEC_SUB or use the prefix "SUB_" (not case sensitive).
GX IEC Developer Reference Manual 6 – 1
Tasks
6.2.1
Programming
Event-triggered Tasks
Events can have the following Boolean values:
쎲 TRUE/FALSE: Tasks with the event value TRUE are always executed. The TRUE or
FALSE parameter is automatically converted to UPPER CASE letters!
쎲 Interrupts: Interrupt-triggered execution control is only possible with input modules that support this function. The task will be executed when the interrupt polled is set. The interrupt number (e.g.: I20) is entered after Event in the task attributes in the Task
Information dialogue box.
Series
Usable interrupts
A
I0–I31
FX
I000–I899
Q
I0–I255
QnA
I0–I31
Tab. 6-1:
Interrupt ranges for each CPU series
NOTE
NOTE
6.2.2
Remember that the EI instruction (Enable Interrupt) must be programmed in a MELSEC network or the function EI_M must be used within the project when using interrupt-triggered tasks.
POUs assigned to interrupt triggered tasks must not be programmed in SFC language.
쎲 Relays: The task is executed when the corresponding relay is set (e.g.: M100).
쎲 I/Os: The task is executed if the status conditions of the corresponding inputs or outputs are satisfied (e.g.:
X0).
쎲 Global variables: All global variables of data type BOOL could be used to control a task.
Elements of arrays or components of data unit variables could not be used.
For every event or interval-triggered task one system label is allocated (
Event-triggered tasks with Timer/Output Control (MC-MCR execution)
If you enter a Boolean device as an event or a time interval you can then select the Timer /
Output Control option.
Fig. 6-2:
Task Information
6 – 2
MITSUBISHI ELECTRIC
Programming Tasks
The following table explains how this option influences the processing of the task.
Execution mode
Task event
Execution sequence
Behaviour when event is active
Behaviour when event is not active
Timer / Output Control not activated
Normal execution
Timer / Output Control activated
MC-MCR execution
X100 X10
LDI X10
CJ End of Task
POU Code
End of Task
If X10 is set the POU associated with the task is executed.
If X10 is not set the PLC program jumps to the end of the task.
The program jumps to the end of the task but some of the device statuses are preserved:
- Timers: continue to run (A, FX) or with
Timer scheduler for Q, QnA
- Timers: stop running for Q, QnA without Timer scheduler
- Retentive/accumulator timers and counters: status preserved
- Devices in OUT instructions: status preserved
LDI X100
ANI MC Relay
CJ End of Task
LD X100
MC N0 MC Relay
POU Code
MCR N0
End of Task
If X100 is set execution of the program sequence between the MC and MCR instructions begins.
If X100 is not set the program sequence between the MC and MCR instructions is executed once with the MC relay set to
FALSE.
If the MC relay is also not set the PLC program jumps to the end of the task.
The statuses of the devices are reset:
- Timer: Count value reset to 0, contacts remain off
- Retentive timers and counters: count value and input contact status preserved, output contact is reset
- Devices in OUT instructions: outputs are reset
- Devices in SET, RST, SFT instructions: current status preserved
Tab. 6-2:
Effect of Timer / Output Control option
6.2.3
Interval-triggered Tasks
The intervals are entered as time constants. If a task is to be executed at intervals you must enter FALSE for the Event parameter in the Task Information dialogue box.
Syntax:
[Time]
T#[Time]
This is the value for the interval duration.
Example: 12h30m, 5s, 100ms
You can also use a global variable of data type TIME as interval of a task. Elements of arrays or components of data unit variables could not be used.
E
WARNING:
You must consider the program cycle period when defining the interval duration!
Defining intervals shorter than the program cycle period can lead to unpredictable results. When in doubt, always calculate the cycle period of the task using the instruction execution times listed in the controller manual.
GX IEC Developer Reference Manual 6 – 3
Tasks Programming
6.2.4
NOTE
6.2.5
Priority-controlled Tasks
The task with the lowest priority value has priority and it will call its associated programs first.
You can assign priority values between 0 and 31.
How to define task execution attributes
햲 In the Project Navigator window, select the name of the task you wish to edit.
햳 Press the key combination ¦« to open the Task Information dialogue box.
햴 Enter your values for the task attributes.
햵 Confirm with OK.
The attribute settings are shown in parentheses behind the name of the task in the Project
Navigator window.
Fig. 6-3:
Tasks in order of their execution priority:
– Event-triggered via Interrupt I0
– Event-triggered via M100
– Event-triggered via X10
– Always executed
– Interval-triggered, every 10 ms
The procedure for creating a new task is described in chapter 4.
Special task MELSEC_FIRST
If you name a task in a special way:
MELSEC_FIRST
(not case sensitive), it is handled with its assigned POUs
쎲 The assigned POUs will be the first ones in the MAIN sequence program.
쎲 All internal code parts from the code generator which must be positioned at the beginning of the MAIN sequence program will be positioned behind this task.
The following checks are performed during the code generation and will cause an error on occurrence:
쎲 Interrupt events are not possible for this task.
쎲 Because SFC POUs must be initialised in the first scan before they are used, they could not be assigned to this task.
쎲 The SFC control functions SFC_CTRL and SFC_PAUSE use a semaphore which is reset at the beginning of the MAIN sequence (now after MELSEC_FIRST). Therefore this functions could not be used directly by programs assigned to MELSEC_FIRST or within their calltree.
The task priority is ignored for MELSEC_FIRST – you are informed of this circumstance by a warning. All errors or warnings are displayed in the error listbox.
6 – 4
MITSUBISHI ELECTRIC
Programming Variables
6.3
6.3.1
NOTE
6.3.2
Variables
Global and Local Variables
Variables are similar to operands. They contain the values of inputs, outputs or internal memory locations in the PLC. There are two types of variables:
쎲 Global Variables
쎲 Local Variables
Global Variables
Global variables are defined for the entire project. They are accessible from any POU body, action or transition, and they make it possible to exchange data between all the sub-programs that go to make up the project.
Local Variables
Local variables (VAR) are only accessible within the one specific program organisation unit
(POU) in which they are declared. Thus, they cannot be used for exchanging data between
POUs.
When there is a local variable declared in a POU with the same name as a global variable, the global variable is hidden, i.e. it is not possible to read or write the value of that global
variable – always the local variable is referenced instead. (See also section 2.9.2.)
Variable declarations
Each variable declaration has the following elements:
쎲 Class,
쎲 Identifier,
쎲 Data type,
쎲 Initial value (automatically),
쎲 Comment (optional),
쎲 Remark (optional).
GX IEC Developer Reference Manual 6 – 5
Variables
6.3.3
Programming
Class
The class keyword assigns the variable a specific property that defines how it is to be used in the project.
Class
VAR
VAR_CONSTANT
VAR_INPUT
VAR_OUTPUT
VAR_IN_OUT
VAR_GLOBAL
VAR_GLOBAL_CONSTANT
—
—
—
X
X
Use in POUs:
PRG FUN FB
X X X
X X X
X
—
—
—
—
X
X
X
X
X
Meaning
Variable that is only used within the POU
Local variable with unchangeable initial value used within the POU
Variable passed from outside that cannot be altered within the POU
Variable passed (output) by the POU
Local variable passed from outside and passes
(output) by the POU, can be altered within the POU
Global variable declared in the Global Variable List
Global variable with unchangeable initial value declared in the Global Variable List
Tab. 6-3:
Use of classes in POUs
6.3.4
Identifiers and Absolute Addresses
Each variable is given a symbolic address, i.e. a name. This is referred to as the identifier; it consists of a string of alphanumeric characters and underline characters. The identifier must always begin with a letter or an underline character. Spaces and mathematical operator characters (e.g. +, -, *) are not permitted.
Examples of identifiers:
FAULT
ZEROSIG
LIM_SW_5
When global variables are declared absolute addresses can be assigned that reference the memory location of the variable in the CPU or a physical input or output.
When local variables are declared in the header of the POU they are automatically assigned a suitable memory location in the CPU.
You can use either the IEC syntax (IEC-Addr.) or the MITSUBISHI syntax (MIT-Addr.) to assign the absolute addresses. Two address columns are available.
As soon as you have entered an address in one of these columns, the other address also appears. You can enter either of the two address formats in both columns. If, for instance, you enter a MITSUBISHI address in the IEC column, GX IEC Developer identifies it immediately, places it in the correct column and produces the matching IEC address in the other column.
Use upper case letters only and no spaces or mathematical operator characters
(e.g. +, -, *) in addresses.
6 – 6
MITSUBISHI ELECTRIC
Programming Variables
When you define global variables you must specify the hardware addresses for each individual variable. The address declarations are shown in the table below.
Size
햶
Range Example MITSUBISHI
Address
X
IEC
Address
%I X
Y
D
W
햴햶
R
햴햶
M / L / S
햲햳
B
햴햶
S
햳
T Contact
햸
T Value
C Contact
C Value
T Coil
C Coil
A
햴
V
햳햴
Z
I
P
F
L
햶
V
햶
N
%Q
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
X
W, D
X
햶
W, D
X
햶
W, D
X 5
X
X
X
X
X
X
X
W
X
W, D
X
X
W,D
W,D
W
X
햶
0
0
1
1
2
2
0
3
3
4
1
2
4
7
8
9
5
6
5
6
7
7
X0
X1F
X37
X7FFF
Y0
Y1F
Y37
Y7FFF
D450
D501+
D502
D0.5
D100.F
W35F
W301+
W302
W35F.5
W35F.F
R450
R501+
R502
R450.5
R450.F
M0
M1024
B3F
S10
TS10
TN40
CS10
CN10
CN210
TC20
CC20
A0
A0+
A1
V1
V2+
Z2
Z2
Z2.5
Z2.F
F20
L30
V47
↔
↔
↔
↔
↔
↔
↔
↔
↔
Not permitted in IEC
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
%IX0
%IX31
%IX31
%QX0
%QX31
%QX31
햴
햵
%IX32767
%MD5.0
%MD6.2
햴
햵
%QX32767
햶
%MW0.450
%MD0.501
%MX0.0.5
%MW2.450
%MW6.1
%MW7.2
%MX7.2.5
%MX7.2.15
%MX7.20
%MX8.30
%MX9.47
Cf. network label
Only allowed in event-triggered tasks
햶
%MX0.100.15
%MW1.863
%MD1.769
%MX1.863.5
%MX1.863.15
%MD2.501
%MX2.450.5
%MX2.450.15
%MX0.0
%MX0.1024
%MX1.63
%MX2.10
%MX3.10
%MW3.40
%MX4.10
%MW4.10
%MD4.210
%MX5.20
%MX6.20
%MW5.0
햵
Tab. 6-4:
Address declarations for variables (1)
GX IEC Developer Reference Manual 6 – 7
Variables Programming
SB
햶
SW
햶
ZR
햶
ST Contact
햶햸
ST Value
햶
U \G
햶
J \SW
햶
BL
햶
TR
햶
DX
햶
DY
햶
FX
햶
MITSUBISHI
Address
K
H
SM
햶
SD
햶
ST Coil
햶
J \X
햶
J \Y
햶
J \B
햶
J \SB
햶
J \W
햶
FY
햶
FD
햶
IEC
Address
16#
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%M
%I
%Q
%M
%M
%M
%M
%M
%M
%M
%M
%I
%Q
Size
햶
X
W, D
X
X
W, D
X
W, D
X
X
W
W, D
X
X
W, D
X
X
X
W
X
X
X
X
X
X
W, D
Range
12
12
14
15
16
16
16. .1
16. .1
16. .1
16. .1
16. .11
16. .11
1
1
17
18
13
13
14
11
11
11
10
10
10
J
햶
U
햶
Tab. 6-4:
Address declarations for variables (2)
Example
K0
HFF
SM1024
SD450
SD45.5
SD45.F
SB3F
SW35F
SW5F.5
SW5F.F
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
↔
0
16#FF
%MX10.1024
%MW10.450
%MX10.45.5
%MX10.45.15
%MX11.63
%MW11.863
%MX11.95.5
%MX11.95.15
ZR327
ZR40501 +
ZR40502
ZR27.5
ZR27.F
STS10
STN40
↔
↔
↔
↔
↔
↔
%MW12.327
%MD12.40501
%MX12.27.5
%MX12.27.15
%MX8.10
%MW8.40
U1\G8
U2\G10 +
U2\G11
U1\G8.5
U1\G8.F
STC20
J1\X1F
J1\Y1F
J2\B1F
J2\SB1F
↔
↔
↔
↔
↔
↔
↔
↔
↔
%MW14.1.8
%MD14.2.10
%MX14.1.8.5
%MX14.1.8.15
%MX9.20
%IX16.1.31
%QX16.1.31
%MX16.2.1.31
%MX16.2.11.31
J1\W35F
J1\W301 +
J1\W302
J1\W5F.5
J1\W5F.F
↔
↔
↔
↔
%MW16.1.1.863
%MD16.1.1.769
%MX16.1.1.95.5%MX16.1.1.
95.15
J1\SW35F
J1\SW301 +
J1\SW302
J1\SW5F.5
J1\SW5F.F
BL319
TR511
DX1F
DY1F
↔
↔
↔
↔
↔
↔
↔
%MW16.1.11.863
%MD16.1.11.769
%MX16.1.11.95.5
%MX16.1.11.95.15
%MW17.319
%MX18.511
%IX1.31
%QX1.31
Not needed in IEC corresponds to VAR_INPUT
Not needed in IEC corresponds to VAR_OUTPUT or function result
Not needed in IEC corresponds to VAR_OUTPUT, VAR_INOUT or function result
Not permitted in IEC
Not permitted in IEC
6 – 8
MITSUBISHI ELECTRIC
Programming
6.3.5
6.3.6
6.3.7
Variables
Table notes
햲
M, L and S devices are not compatible to old MEDOC projects. The system does not check whether latch relay devices L (e.g. L100) are within the latch range of the relay devices M.
Memory-buffered M relays are not displayed as L latch relays.
L and S relays are handled differently in the Q/QnA series.
햳
In the A series CPUs the step status devices S are treated in the same way as M relay devices. For example, this means that M100 and S100 are identical.
In the F and Q/QnA series CPUs the S devices are treated as step status devices
The devices S can not be used by the user program.
햴
Applies for A series controllers only
햵
Applies for F series controllers only
햶
Applies for Q/QnA series controllers only
햷
The size prefix is optional, i.e. the entries %IX10 and %I10 are effectively identical.
Prefixes:
X Bit device
W Word device
D Double word device
햸
The following types of MITSUBISHI devices are used for timers and counters:
STS, TS, CS Contact (Timer, Counter)
STC, TC, CC
STN, TN, CN, T, C
Coil (Timer, Counter)
Value (Timer, Counter)
Initial Value
The initial values are set automatically by the system and cannot be changed by the user.
Comment
You can add a comment up to 64 k characters long for each variable.
Remark
You can add additional user information.
GX IEC Developer Reference Manual 6 – 9
Variables Programming
6.3.8
NOTES
Data Types
The data type of a variable defines the number of bits it contains, how they are processed and the variable’s value range. The following data types are available.
BOOL
INT
DINT
WORD
DWORD
REAL
TIME
STRING
햲
Data type
Boolean
Integer
Double integer
Bit string 16
Bit string 32
Floating-point value
Time value
Character string
Value range
0 (FALSE), 1 (TRUE)
-32768 to 32 767
-2147483648 to 2147483647
0 to 65535
0 to 4294967295
3.4 E +/- 38 (7 digits)
T#-24d-0h31m23s648.00ms
to
T#24d20h31m23s647.00ms
max. 50 characters
Size
1 Bit
16 Bit
32 Bit
16 Bit
32 Bit
32 Bit
32 Bit
Tab. 6-5:
Data types
햲
You can set the default value for the number of characters in string variables with the option
Extras - Options - General - Default String Length (characters).
The data type STRING with a maximum length of 50 characters is only available for
MELSEC Q/QnA series.
When using the data type STRING with the A series or the FX series (only FX2, FX2C, and
FX2N(C)) a maximum length of 8 characters is alowed.
With these CPU series the string cannot be manipulated using dedicated instructions.
Data unit types (DUT) are structured, derived data types containing a collection of variables which can be of different data types (
6 – 10
MITSUBISHI ELECTRIC
Programming Variables
Data types hierarchy ANY
ANY_NUM
ANY
ANY_SIMPLE
ANY_BIT
BOOL
WORD
DWORD
TIME
ANY_REAL
REAL
ANY_INT
INT
DINT
Fig. 6-4:
Data types hierarchy ANY
Data types hierarchy ANY16 and ANY32
ANY_16
STRING
ANY_32
ARRAY DUT
Fig. 6-5:
Data types hierarchy ANY16 and ANY32
WORD INT DWORD DINT
GX IEC Developer Reference Manual 6 – 11
Variables
6.3.9
Programming
Address Batch Replace
The Address Batch Replace function is available for the global variable list of the project and in the global variable lists of the included libraries.
This function replaces an existing address range by a new address range.
In the Tools menu select Address Batch Replace to open the following dialogue.
Fig. 6-6:
Address batch replace
Example
The address range can be entered in either IEC or Mitsubishi format. Both formats must not be combined.
The greyed last entry field is calculated automatically.
Fig. 6-7:
Address batch replace settings
NOTE
The variables with the addresses D100 – D199 are replaced by the addresses D200 – D299. A variable with the address D100.0 will be changed to D200.0.
쑶
The Undo function is not supported for the Address Batch Replace.
6.3.10
Auto Update
Global and local variables can be updated automatically by the Auto Update function. This
function can be activated via the menu Extras - Options - Editing (refer to 2.8.3).
The following changes of a variable declaration are updated: Class, Identifier, Address, Type,
Initial. All changes made in the GVL will also be executed in the POUs. When you change a
POU header, its body will also be changed automatically. The variables are updated after the declaration editor changes have been saved.
Via the menu Extras - Update Variables all references of the selected local variables are updated, if the name of the local variable has been changed. For every reference to be updated a message box appears where you can decide to update the reference or not.
6 – 12
MITSUBISHI ELECTRIC
Programming Programming Languages
6.4
Programming Languages
6.4.1
NOTE
Networks
Programming is done in ‘networks’ in all programming languages except Sequential Function
Chart (SFC) and Structured Text (ST). You can define multiple networks, each of which is identified with a network label. It is then possible to switch from one network to another within the PLC program by using jump instructions in the program code. For a detailed description of
this please refer to chapter 3.
Network labels can have a maximum of eight characters and must always be terminated with a colon (:). You can also assign a title to each network. These network titles can be descriptive names up to 22 characters long, and using them makes handling large projects with many networks a great deal easier.
Remember that every network label uses one system label and that the total number of system labels is limited to a maximum of 256. Since system labels are also needed for other elements in GX IEC Developer (
Þ page 2-51), you should only define labels to networks to
which you actually intend to perform a jump.
The Network List
The networks in your program organisation units are managed in the Network List, which you can only open when the body window of the corresponding POU is open. The list window contains all the POUs networks with their labels and titles. In the window you can add more networks and edit existing ones. A search function (Find) is provided for finding specific networks quickly (
E
WARNING:
For all practical purposes it is not possible to change the programming language of a
POU once you have selected it. The system will allow you to make the switch, but if you do this you will lose all the code in the body. You should thus only switch the programming language of bodies that do not contain any code!
GX IEC Developer Reference Manual 6 – 13
Programming Languages Programming
6.4.2
NOTE
Text Editors
Instruction List (IL)
Programming in Instruction List is performed with a simple text editor.
An Instruction List program consists of a sequence of controller instructions. Each controller instruction must contain an operator or a function or function block and one or more operands/variables. Each controller instruction must begin in a new line. You can also add optional comments to each instruction. All the programming elements in the individual instructions must be separated by tab stops.
MELSEC Instruction List
The user interface for programming in MELSEC IL is identical to that for IEC IL. However, only the ‘Pure’ MELSEC instruction set is supported (
Þ Appendix E); you cannot write IEC
standard programs in the MELSEC IL editor. The functionality of the MELSEC IL language corresponds to that of the MELSEC MEDOC programming and documentation system. This enables you to easily import programs developed with MELSEC MEDOC and integrate them into your GX IEC Developer programs
(
IEC Instruction List
The user interface for programming in IEC IL is identical to that for MELSEC IL. There are just a few differences in programming:
쎲 MELSEC Networks in IEC IL
You can also integrate MELSEC networks in IEC IL programs, thus effectively giving you access to the ‘Pure’ MELSEC programming instructions.
쎲 The Accumulator
The accumulator is a result management system often used in high-level languages. The result of every operation is stored in the accumulator directly after execution of the instruction. The accumulator thus always contains the operation result of the last instruction executed.
You do not need to program any input conditions (execution conditions) for the operations; execution always depends on the contents of the accumulator.
The difference between programming in the MELSEC editor (with execution condition) and in the IEC editor (with accumulator) is described in the Beginner’s Manual (
Structured Text (ST)
ST is a text-oriented editor (programming language), similar to PASCAL and supports mathematical functions and a simple creation of loops.
ST body does not contain a network list because it always consists of only one network.
ST is an editor from the IEC 61131 programming standard. The Structured Text editor is compatible to the IEC 61131-3.
All IEC 61131 (IEC 61131-3: PART3-1992) standard functions are supported.
All MELSEC instructions are supported.
6 – 14
MITSUBISHI ELECTRIC
Programming Programming Languages
6.4.3
Graphical Editors
Ladder Diagram (LD)
In Ladder Diagram you can use both IEC and MELSEC programming instructions in every network. A Ladder Diagram program consists of contacts (break and make), coils, function blocks and functions. These elements are connected with horizontal and vertical lines called interconnects. The circuits always begin at the power bar on the left.
Functions and function blocks are displayed as graphical blocks. In addition to their input and output parameters, some blocks also have a Boolean input (EN = ENable) and a Boolean output (ENO = ENable Out). The status of the output always corresponds to that at the input.
E
WARNING:
You must normally create a separate network for each circuit in a Ladder Diagram program. However, you can also create an additional power bar parallel to the standard one provided by the editor, connecting the two at one point. This option makes it possible to perform programming in just one network where this is more convenient.
Function Block Diagram (FBD)
In Function Block Diagram language, as in Ladder Diagram language, you can use both IEC and MELSEC programming instructions in every network (
Þ Appendix E). All instructions are
implemented using graphical blocks, which are connected with one another with horizontal and vertical connecting lines. There are no power bars (rails) in Function Block Diagram language.
Functions and function blocks are displayed as graphical blocks. In addition to their input and output parameters, some blocks also have a Boolean input (EN = ENable) and a Boolean output (ENO = ENable Out). The status of the output always corresponds to that at the input.
E
WARNING:
In Function Block Diagram language you must create a separate network for each circuit.
GX IEC Developer Reference Manual 6 – 15
Programming Languages Programming
6.4.4
NOTE
Sequential Function Chart (SFC)
Sequential Function Chart is a graphical language. Strictly speaking it is not really a genuine programming language but rather a structural tool which allows a clear representation of processes.
The program (PRG) is the only program organisation unit supported in SFC.
SFC language has two basic elements, Steps and Transitions (continue conditions). A SFC program sequence consists of a series of steps separated by transitions. Only one step can be active at any one time in such a program sequence except in parallel branches. The next step in the sequence is activated when the preceding step/steps is/are active and the transition condition is satisfied.
Steps and Actions
Several actions can be assigned to one step. An action can be a Boolean output variable or a piece of program, which can be written in any of the editors, including Sequential Function
Chart itself. All actions are listed in the Action Pool in the Project Navigator window. A step to which no action is assigned is treated as a wait loop that stops execution until the following transition condition is fulfilled. A step is activated when the transition condition (continue condition) immediately preceding it is fulfilled.
Steps are represented graphically as rectangles containing a name (descriptor).
Macro Steps
Each step can be declared as a macro step, which in turn consists of a sequential structure. The only limitation on the nesting depth of such structures is the memory capacity of the controller used.
Macro steps are identified by two additional horizontal lines within the step rectangle.
Transitions
Each transition has a transition condition. Transition conditions can be programmed in the
Instruction List, Ladder Diagram, Function Block Diagram, MELSEC IL and ST language. It is also possible to use a Boolean variable, direct address, or constant.
Like the steps, the transitions are also listed in the Project Navigator window.
Transitions are displayed in the editor with a small box lying on the vertical connecting line between the steps.
Initial Step
An SFC sequence always begins with an initial step. The initial step does not have to be at the beginning, however – it can also be placed at another point in the sequence.
The initial step is always the first step that is executed in an SFC program, even if it is not placed at the physical beginning of the sequence.
The initial step is identified by a double outline.
6 – 16
MITSUBISHI ELECTRIC
Programming Programming Languages
NOTE
Branching
SFC programs support both selective and parallel branching. Selective branches divide into two or more transition conditions. Parallel branches are always inserted after transitions, and they can activate actions or jumps.
Selective branching
In a selectively-branched sequence not more than one step can be active simultaneously. If the transition conditions of two or more transitions in a selectively-branched sequence are active at the same time the execution priority is determined on the basis of the order of the sequences from left to right. This means that only the sequence that is furthest to the left will be executed. The sequences to the right of this sequence will not be executed, even if their transition conditions evaluate true.
Selective branches are displayed as single horizontal lines.
Parallel branching
Parallel-branched sequences allow the activation of multiple steps simultaneously. The steps leading off the parallel branch become active as soon as the preceding step and the transition condition are satisfied.
Several processes can be executed simultaneously in parallel branches.
Parallel branches are displayed as double horizontal lines.
pJumps
Each jump destination is always directly followed by a step. You can thus only insert a jump destination when the step which is to follow it is selected. The jump must always be programmed after a transition, as it replaces the step that would normally come in this position.
This means that no further steps or transitions can follow a jump, which is thus also the final instance within its SFC sequence. The relationship between the jump and jump destination is established by using the same label (name) for both of them.
When you program a jump instruction pressing
displays a list of all the labels (i.e. potential jump destinations) that have already been defined. You can then simply select the appropriate label from the list and confirm to enter it.
You will find examples of the sequencing rules described here on the following pages.
GX IEC Developer Reference Manual 6 – 17
Programming Languages Programming
EMERGENCY OFF for FX Series
For the FX series PLCs it is possible to integrate an EMERGENCY OFF switch in an SFC program. All step relays in the sequence are reset as soon as the EMERGENCY OFF switch is activated. The calculated values in the steps are not lost when this happens. The program process branches back to the initial step. This does not mean that the complete sequence is re-initialized, however – the sequence is only interrupted. You should always exercise caution when restarting processes.
The SFC reset variable (in the following example it is a local variable called
EMERGENC_OFF) can be either a local or a global variable with the type BOOL or ARRAY OF
BOOL. When an ARRAY OF BOOL variable is given, its first element will be used as the reset variable.
Fig. 6-8:
EMERGENCY OFF
The assignment of the SFC reset variable to the SFC POU is introduced in the POU information dialogue. When you call Object Information for the marked SFC POU (in this example called POU_SFC_01), the following dialogue provides the setting for the SFC reset variable.
Input the identifier of the required local or global variable in the field SFC reset.
Fig. 6-9:
Entering the variable identifier for the SFC reset variable
6 – 18
When pressing OK in this dialogue, the syntax of the entered name will be checked, but it will not be verified whether the entered name specifies an existing variable. When the POU or the project is checked (or built), and the SFC reset setting does not specify a valid variable, an error will be added to the list of errors and warnings in the Compile/check messages dialogue.
Fig. 6-10:
Warning message in case of a syntax error
MITSUBISHI ELECTRIC
Programming Programming in Sequential Function Chart Language
6.5
NOTES
Programming in Sequential Function Chart
Language
Programming in SFC language calls for systematic analysis of the control sequence before you start. The algorithm for implementing the control task should be drawn up in a systematic step-by-step procedure. SFC programs are planned on the basis of statuses and status transitions. One starts by identifying all the statuses in the process and connecting them with status transitions. The general statuses formulated in the first program development phase can then be gradually made more precise. In the final phase each status is implemented in a step and each status transition in a transition.
For the use of SFC programs you can set some CPU specific parameters (
The PLC holds an active information table to be able to activate the active steps of the SFC
POUs after a switch from Stop to Run. For this the SFC program start mode has to be set to
Resume start (on the page SFC in the PLC's parameters).
When the entry AdjustSFCActiveInfoTable in the [OPTIONS] section of the MMP703.INI file
(
Þ Section 2.6) is set to TRUE, the active step information table is updated during download
for QnA and Q PLCs. If it is set to FALSE in the MMP703.INI file the active step information table is not updated and the PLC will raise an error when the offset of the active steps have been changed or a new SFC POU has been added or one has been deleted.
If AdjustSFCActiveInfoTable is set to TRUE the following updates are done during download:
쎲 The offsets of the active steps are adjusted when the SFC program has been changed.
쎲 The information of a SFC block, which corresponds to a SFC POU, is deleted from the active step information table of the PLC when the SFC POU has been deleted.
If a SFC POU has been added, the active step information table is expanded. The initial step of the new SFC POU is automatically activated.
In the Beginner’s Manual (
Þ Chapter 6) you will learn step by step how to create an SFC program and to use the tools in the SFC editor.
The Q25SS (SX Controller) CPUs do not support the SFC language.
GX IEC Developer Reference Manual 6 – 19
Programming in Sequential Function Chart Language Programming
6.5.1
NOTE
Sequential Function Chart Language Program Structure
The body of a newly-generated SFC POU always consists of the initial step, a transition and the final step.
When you are first trying out the SFC editor it’s a good idea to keep an eye on the active tools in the Toolbar. Only the elements whose tool icons are active can be inserted at the selected position. Create a test program to experiment with all the available ways of using SFC language elements.
The following basic rules of thumb will help you with writing your first SFC programs:
쎲 Each step must always be followed by a transition, each transition by a step.
The only exceptions to this rule are exit and entry steps (jumps and jump destinations).
Both of them ‘replace’ steps, and they must thus always be programmed directly after transitions. Entry steps (jump destinations) must logically always be followed by a step that can be executed. An exit step (jump) must always be programmed after a transition that is not followed by a step.
쎲 Selective branches can only be inserted before transitions.
Since a selective branch polls a variety of conditions before executing a step these conditions must be placed in transitions directly after the branch.
쎲 Parallel branches can only be inserted after transitions.
This is because a parallel branch has the effect that two or more steps are performed simultaneously after a common transition.
쎲 You must assign a transition condition to every transition in the program.
A transition condition is a program, Boolean variable, address or constant that defines the conditions under which the transition to the next step is to be enabled.
쎲 You can assign an action to every step in the program.
An action can be either a program or a Boolean output variable. Please note that an action’s program is not a POU, however!
6 – 20
MITSUBISHI ELECTRIC
Programming
6.5.2
Programming in Sequential Function Chart Language
Sequence rules and examples
Simple sequences
STEP_1
Fig. 6-11:
A simple sequence consists of a series of alternating ‘Step – Transition’ pairs.
TRAN_1
STEP_2
Example:
The transition from STEP_1 to STEP_2 is only executed if STEP_1 has been executed and transition condition TRAN_1 evaluates true.
Divergence into selective sequences
STEP_1
TRAN_1
STEP_2
TRAN_2
STEP_3
Fig. 6-12:
Branching to a selection of alternative sequences
(divergence) is programmed by programming one transition beneath the horizontal line for each alternative sequence to be included in the selection. Note that if several transition conditions evaluate true at the same time only the sequence that is furthest to the left will actually be executed! Example:
The transition from STEP_1 to STEP_2 only takes place when STEP_1 has been executed and transition condition TRAN_1 evaluates true. The transition from
STEP_1 to STEP_3 only takes place when STEP_1 has been executed, TRAN_2 evaluates true and TRAN_1 evaluates false.
Convergence from selective sequences
STEP_1
STEP_3
TRAN_1
STEP_2
TRAN_2
Fig. 6-13:
The end of a selectively branched sequence is converged again by programming one transition above the horizontal line for each branch sequence to be terminated.
Example:
The transition from STEP_1 to STEP_3 only takes place when STEP_1 has been executed and transition condition TRAN_1 evaluates true. The transition from
STEP_2 to STEP_3 only takes place when STEP_2 has been executed and TRAN_2 evaluates true.
GX IEC Developer Reference Manual 6 – 21
Programming in Sequential Function Chart Language
Fig. 6-16:
This is a special form of selective branching in which one or more alternative branches contain no steps.
Example:
If and only if TRAN_1 is false and TRAN_2 is true the transition runs from STEP_1 to STEP_4, skipping STEP_2 and STEP_3.
Programming
Divergence into parallel sequences
STEP_1
STEP_2
TRAN_1
STEP_3
Fig. 6-14:
You can only program one transition directly above the double horizontal synchronisation line.
Example:
The transition from STEP_1 to STEP_2 and STEP_3 only takes place when STEP_1 has been executed and transition condition TRAN_1 evaluates true. Following simultaneous activation of STEP_2 and STEP_3 the two sequences are executed in parallel, independently of one another.
Convergence of parallel sequences
STEP_1
STEP_2
Fig. 6-15:
You can only program one common transition beneath the double horizontal synchronisation line.
TRAN_1
STEP_3
Example:
The transition from STEP_1 and STEP_2 to STEP_3 only takes place when both STEP_1 and STEP_2 have been executed and are connected by the double horizontal line above the transition. The transition condition TRAN_1 must also evaluate true.
Empty branches
STEP_1
STEP_2
TRAN_1
TRAN_2
TRAN_3
STEP_3
TRAN_4
STEP_4
6 – 22
MITSUBISHI ELECTRIC
Programming Programming in Sequential Function Chart Language
Exit and Entry Steps (Jumps)
STEP_1
STEP_3
TRAN_1
STEP_2
TRAN_2
TRAN_3
LABEL_1
쐇
TRAN_4
LABEL_2
쐃
Fig. 6-17:
A transition condition can be followed by an exit step instead of a step. The label of the exit step references the corresponding entry step , which can be placed anywhere in a sequence directly before an executable step. The exit and entry steps must have the same designators
(names). This structure can be used to program loop constructs.
Example:
The sequence is processed up to STEP_3. Then, if STEP_3 has been executed, TRAN_3 evaluates false and TRAN_4 evaluates true, execution performs a jump back to STEP_2 via LABEL_1.
STEP_4
쐇
쐃
쐊
쐎
쐋
쐏
쐄
쐂
Fig. 6-18:
Creating a Sample Program
Operations and Order of Procedure:
Step and Transition
Parallel Branch (Divergence)
Convergence
Step and Transition
Selective Branch (Divergence)
쐆
Step and Transition
Step and Transition
Step and Transition
Convergence
The illustration shows the creation of an example program in nine steps. The shaded areas show the position of the selection highlight for insertion of the corresponding element.
GX IEC Developer Reference Manual 6 – 23
Programming in Sequential Function Chart Language
6.5.3
6.5.4
6.5.5
Programming
Editing elements in the SFC language
You can edit all the elements in an SFC sequence. The commands for editing elements are accessed in the Edit menu under Modify. Here too, only the commands that can be performed for the current selection are active:
쎲 Initial step
쎲 Final step
쎲 Macro step
쎲 Entry step
쎲 Exit step
Content indication in SFC editor
The content of a body or transition in an SFC can be indicated by a filling in a user-definable color. The color can be defined in the menu View - Colors - SFC Raster Elements.
The filling indicates that
쎲 A step includes an assigned action
쎲 A transition includes an assigned condition
Zoom functions
Zoom functions for transitions
If you have not yet created a transition double-clicking on the transition symbol opens the New
Transition dialogue box for the definition of a new transition.
If the transition has already been defined double-clicking on the transition symbol opens the editor for the creation of the corresponding PLC program.
Zoom functions for steps
The Step Zoom Into option in Extras - Options - Zoom Header/Body enables you to define which dialogue box is to be opened when you double-click on a step symbol.
Step Action Association: Action Association dialogue box: Association of an action to a step
First Action If Any: If at least one action is already associated to the step the PLC program of the first action in the list is opened for editing.
Comment: Dialogue box Comment: Enables you to enter a comment text. If you want the comment text to be displayed on the screen in the step box you must activate the Extended
Information feature in the View menu. This will also display additional information in the Project
Navigator window (
6 – 24
MITSUBISHI ELECTRIC
Programming Programming in Sequential Function Chart Language
6.5.6
NOTE
NOTE
Assigning Actions to Steps
You can assign actions to every step. An action is a program that can be written in Instruction
List (IEC or MELSEC), Ladder Diagram, Function Block Diagram, or MELSEC ST language.
These programs are all listed in the Action Pool in the Project Navigator window.
How to associate actions to steps
햲 Select the step to which you wish to assign an action.
햳 Select Edit Action Association in the Tools menu to open the Action Association dialogue box.
햴 Press to open the Action Name List, which shows all the programs in the Action Pool.
The procedure for creating a new action is described in chapter 4 (‘How to create new
objects’).
햵 Select the required action and confirm with OK. The name is then displayed in the
Action Association field.
햶 Press ° to close the dialogue box.
The selection of actions from the Action Name List as described in step
햴 is for the association of programs already stored in the Action Pool. If no actions have yet been created a message is displayed when you press
.
The action associated with a step does not have to be a program; you can also associate steps with direct operands, effectively defining the operand as an action.
Steps that have already been associated with actions are shown shaded in the editor.
If the background colour and the SFC grid element colour are the same, which is set as the default, it is not visible!
GX IEC Developer Reference Manual 6 – 25
Programming in Sequential Function Chart Language
6.5.7
Programming
Assigning Transition Conditions
Each transition must be associated with a transition condition. A transition condition can be
쎲 a program written in the IL, ST, LD or FBD languages
쎲 a ST expression written in a transition condition window
쎲 a constant TRUE or FALSE
쎲 a Boolean variable with the value of FALSE or TRUE
How to assign transition conditions
햲 Open the body of the SFC POU.
햳 Select the transition symbol to which you wish to assign a condition.
햴 Enter the name of the condition.
햵 Select Zoom Body from the Tools menu. The New Transition dialogue box is displayed with the new transition name.
햶 Select the programming language you wish to use for the transition program.
햷 Confirm your selection with OK.
The editing window of the selected language editor is then opened, and the name of the new transition is displayed below the Body entry of the SFC POU in the Project Navigator window.
You can now write the program for the transition condition.
Transitions that have been assigned a name are shown shaded in the sequence chart, even if the associated program has not yet been created. This means that the identification feature that applies for steps does not apply for transitions; you can only check whether the associated program has been created by looking in the Project Navigator window. If the program has been created the name of the transition will appear under the Body entry in the Navigator.
Programming Transition Conditions
Programming a transition condition is the same as programming any other POU. However, the program must be written in a network. Also, you are only allowed to use one output variable, and this variable must have the name of the transition or the name TRAN.
6 – 26
MITSUBISHI ELECTRIC
Programming
6.5.8
Programming in Sequential Function Chart Language
Enhanced Display
If you need information about the actions contained in a step or programs contained in a transition you can automatically open and arrange the respective windows via the Enhanced
Display function. If an SFC body is monitored, the monitor mode is automatically activated for the opened bodies.
How to activate the enhanced display
햲 In an SFC body click on a step or transition to select it.
햳 To open the Enhanced Display context menu right-click on the SFC body or press [Shift]+[F10].
햴 From the context menu select Enhanced Display - Open action / transition.
햵 The action and the transition of the selected item are opened and arranged as shown below. The monitor mode is automatically activated.
Fig. 6-19:
Enhanced display
The body of the action is displayed in the upper right section of the SFC body.
The body of the transition is displayed in the lower right section of the SFC body.
If a step was selected, the first action of this step and the body of the following transition are opened.
If a transition was selected, the body of the first action of the previous step and the body of this transition are opened. If more than one previous step is available (parallel sequences) the leftmost located step is displayed.
Actions and transitions which were already opened will be closed before the Enhanced
Display.
The menu item Enhanced Display - Close windows closes all windows which were opened and arranged automatically.
GX IEC Developer Reference Manual 6 – 27
Programming in Sequential Function Chart Language
6.5.9
Programming
Comments in Sequential Function Chart Language
You can now enter an additional comment for each step in the SFC editor. Each comment can be up to 256 characters long.
Entering comments
햲 Optionally activate the Extended Information - SFC editor option in the View menu to increase the size of the step display in SFC language.
햳 Select the step in the sequence for which you wish to enter a comment. Take care to only mark the step itself and not its name.
햴 Activate the Edit Step Comment option in the Tools menu to display the comment entry dialogue box.
햵 Enter the text of your comment.
Fig. 6-20:
Entering comment text
햶 Press §« to insert the comment text into the box representing the step.
Fig. 6-21:
Inserted comment text
NOTE
햷 You can suppress the comment text display by deactivating the Extended Information -
SFC editor option in the View menu.
See also the Comment option in Extras - Options - Zoom Header/Body - Step Zoom Into
(
6 – 28
MITSUBISHI ELECTRIC
Programming
6.5.10
Programming in Sequential Function Chart Language
Manual SFC Control
Via the manual SFC control a machine can be controlled by manual operation of the SFC sequence.
By mouse or menu operation the selected steps can either be set or reset. Alternatively, all active steps are reset and all selected steps are set.
Before the corresponding command will be executed, a message box appears including one of the following warnings:
쎲 All selected steps are set.
쎲 All selected steps are reset.
쎲 All active steps are reset and all selected steps are set.
You can execute or cancel the selected command.
Step selection
It is possible to select a step either via the mouse or the keyboard. If you want to select more than one step, you can click on the corresponding steps while pressing the [CTRL] key.
Multiple selections via the keyboard are not possible.
Availability
If an SFC body is opened, the sub menu of Debug - SFC Control is enabled.
The submenu SFC Control is also available in a context menu which can be opened either via the key [SHIFT]+[F10] or a right-click on the SFC body.
The submenu SFC Control includes the following menu items:
Set selected steps...: All selected steps are set.
Reset selected steps...: All selected steps are reset.
Replace active by selected steps...: All active steps are reset and all selected steps are set.
The submenu SFC Control is available only if the monitor mode is enabled. If the monitor mode is disabled, the submenu is greyed, I. e. not available.
Limitations
If you select more than one step at time and then call the set or replace function, it will not be checked whether the SFC configuration is valid or executable.
The manual SFC control is not available for selected macro steps.
Code generation for manual SFC control
The step flags of every SFC block can be influenced by automatically generated code.
GX IEC Developer Reference Manual 6 – 29
Programming in Sequential Function Chart Language
6.5.11
Programming
Sequence errors
The following examples illustrate two typical errors in SFC programs.
An ‘unsafe’ sequence
S_1
T_1
S_2
S_3
S_6
T_4
T_6
S_4
T_2
S_5
T_3
S_7
T_5
T_7
Fig. 6-22:
Transition T_4 can only be polled when both S_2 and
S_4 have been executed. However, as soon as T_2 is false and T_3 is true, sequence execution continues with S_5. The result is that it is possible for the process to restart without S_4 being active and without it being possible to execute S_6.
This type of process is referred to as ‘unsafe’.
An ‘inaccessible’ sequence
S_1
T_1
S_2 S_3
S_4
T_2
S_5
T_3
S_6
T_4
T_6
S_7
T_5
Fig. 6-23:
This sequence suffers from a similar problem. In this case, T_6 is completely inaccessible when the sequence containing steps S_5 and S_7 is executed. T_6 can only be polled if both S_6 and
S_7 are active. S_6 can never be active, however, because T_4 can only be polled and execute its transition when S_2 and S_4 are active.
6 – 30
MITSUBISHI ELECTRIC
Programming Programming in Sequential Function Chart Language
6.5.12
NOTE
Start, stop, and initialise SFC for QnA and System Q CPUs
To control SFCs in a project from other program parts, GX IEC Developer provides the following functions: Start, stop, and initialise.
Additionally, a function including inverse logic is available.
SFC control functions
All SFC control functions are declared as manufacturer functions in the Manufacturer Library
(MLIB). These SFC control functions can be used for QnA and System Q CPUs. They are realised as functions which are not called, but directly expanded by the code generator at the locations where they are used.
Functions:
SFC_START
SFC_PAUSE, SFC_PAUSED
SFC_STOP, SFC_STOPPED
SFC_CTRL
The names used for SFC POUs and SFC steps must be valid. If they are invalid, an error message appears.
Additionally, the used SFC POUs must be assigned to a task. If they are not assigned to a task, an error message appears.
Never use SFC_START after SFC_STOP for the same POU. Always use SFC_START
before SFC_STOP or interlock the execution of SFC_START so that both functions can not be executed within the same program scan.
Otherwise, errors like multiple active steps might occur.
SFC_START
Fig. 6-24:
SFC_START
Via SFC_START a paused SFC POU is started again. The step name is not used for paused
SFC POUs.
Via SFC_START also a stopped SFC POU can be started again. If a Step_name is given, the
POU is started at the specified step. If several steps should be activated, several SFC_START functions have to be used.
If a paused SFC POU should continue with the last active step, the empty string must be used.
A stopped SFC POU will be started with its initial step.
Fig. 6-25:
SFC_START
GX IEC Developer Reference Manual 6 – 31
Programming in Sequential Function Chart Language
SFC_PAUSE
Programming
Fig. 6-26:
SFC_PAUSE
When the input EN is TRUE the SFC POU given with SFC_name is paused when it is not already paused.
When the input parameter OUT_mode is TRUE the output of all coils, which are used with an
OUT instruction at the step being executed when the SFC POU will be paused, are maintained.
When it is FALSE they are switched off.
The OUT_mode behaviour is realised with the special relay SM325. The SFC POU is paused when its according block is not executed. The value of SM325 is used to decide how to handle the coils.
To avoid the influence of other SFC_PAUSE functions with a different OUT_mode set, an additional “Pause-is-Currently-Executed-Flag” is used to pause in one scan all SFC POUs with the same OUT_mode set. At the next scan all SFC POUs will be effected where the
OUT_mode has the opposite setting. Therefore for the EN and OUT_mode inputs of the
SFC_PAUSE no pulsed devices should be used.
SFC_PAUSED
Fig. 6-27:
SFC_PAUSED
The status of the given SFC POU is assigned to the output parameter Paused. If the SFC POU is paused, the output parameter Paused is TRUE. If the SFC POU is not paused, the output parameter Paused is FALSE.
SFC_STOP
Fig. 6-28:
SFC_STOP
Via SFC_STOP the specified SFC POU is stopped. All steps are reset and the status of the output of all coils are switched off.
6 – 32
MITSUBISHI ELECTRIC
Programming
SFC_STOPPED
Programming in Sequential Function Chart Language
Fig. 6-29:
SFC_STOPPED
Via SFC_STOPPED the status of the given SFC POU is assigned to the output parameter
Stopped. The output parameter Stopped is TRUE when the SFC POU is stopped. The output parameter Stopped is FALSE when the SFC POU is not stopped.
SFC_CTRL
Fig. 6-30:
SFC_CTRL
The function SFC_CTRL is activated via the EN input. If EN is TRUE, the SFC POU is influenced.
If EN is FALSE, the SFC POU is not influenced.
As long as SFC_ON is TRUE the specified SFC POU will be executed.
If SFC_ON is FALSE, the SFC POU is paused. The output of all coils depends on the input parameter OUT_mode at the step being executed when the SFC POU will be paused.
If SFC_INI is TRUE, the specified SFC POU is stopped. All steps are reset and the output of all coils is switched off at the step being executed when the SFC POU will be stopped.
If SFC_INI is FALSE again and SFC_ON is TRUE, the SFC POU is started with the initial step.
If SFC_ON and SFC_INI are both active, the SFC POU is paused and reset.
The SFC_CTRL can be used within the SFC POU which is controlled by the SFC_CTRL. In this case the SFC_CTRL is executed only when the step containing the action including the
SFC_CTRL function is active. When the SFC POU is paused or reset the SFC_CTRL must be started outside of the SFC POU.
Conditions of using SFC control functions
The control functions SFC_PAUSE and SFC_CTRL, which include “OUT_Mode” influence the relay SM325. This special relay controls the OUT instruction behaviour of SFC POUs.
Since SFC POUs are also paused when they are assigned to a conditioned task, only one of both methods to control the OUT instruction behaviour is allowed to be active at the same time.
This is not checked or guaranteed by the code generator, but must be done by the user.
Therefore, you should use only one method at a time to avoid problems.
GX IEC Developer Reference Manual 6 – 33
Programming in Sequential Function Chart Language
NOTE
Programming
The SFC_STOP function resets a SFC POU to its initial step. The reset of all active steps of a
SFC POU is done by resetting the according block device of the SFC POU. The reset of the active steps is then done by the SFC program handler, when the SFC block should be executed.
This could lead to a problem, when after a SFC_STOP the SFC_START function is activated for the same SFC POU in the same scan. The SFC_START function sets the according block device again and continues or starts the SFC POU. It is also possible to parameterise a step name of the SFC POU, which is activated in addition.
While the block device is set again, the reset of the active steps is not done by the SFC program handler anymore, because the block device has not changed from ON to OFF.
Furthermore SFC_START could activate a step in addition to the currently active steps.
To avoid this problems, in MM+ 3.00 SP2.5 and GX IEC Developer 4.00 and up:
쎲 SFC_START should not be used after SFC_STOP for the same SFC POU.
쎲 Or the execution of SFC_START should be interlocked, so that both functions could not be executed in the same scan.
6 – 34
MITSUBISHI ELECTRIC
Programming
6.5.13
Programming in Sequential Function Chart Language
ST for Boolean transitions
The permanently visible direct variable name or transition name has been expanded by a window, which is shown below the conditions. In this window IEC 61131-3 ST Boolean arithmetic for the Transition Condition can be edited in textual form. These Boolean expressions meet the IEC 61131-3 standard. The transition is executed according to the Boolean expression.
Normally this window will show one line consisting of approx. 25 characters (depending on the selected font, scrollable). A line not completely visible can be indicated by dots. If the transition or the step before is selected (or if it is active in monitor mode), a window of appropriate size is displayed. If text is added into the window, slider bars might appear. The window is not shown when the transition or the step is selected in offline or monitoring mode.
Tools
The command Edit Transition Condition
The command Edit Transition Condition is included in the SFC toolbar and in the menu
Tools.
Edit Transition Condition is available if the SFC editor is active and a transition is selected.
The SFC editor is active if a transition rectangle is marked at the moment. Otherwise the SFC editor is disabled.
The function of this command depends on the current status of the transition or on the current content of the transition’s rectangle respectively.
a) Transition rectangle is empty (no transition defined yet)
쎲 Create a new transition: name="", language = ST.
쎲 Open the Transition Condition editor.
b) Transition rectangle contains a name which is no variable, no transition name, and not TRUE or FALSE
쎲 Create a new transition: name="", language = ST.
쎲 Set transition rectangle to “”.
쎲 Open the Transition Condition editor.
c) Transition is a Boolean variable whose direct address is TRUE or FALSE
쎲 You are asked whether you want to convert the direct variable into a Transition Condition:
“Do you really want to replace ‘varX’ by a Transition Condition?”
– NO: nothing is done, exit function
– YES: continues
쎲 Create a new transition: name=""; language = ST.
쎲 Clear the old transition’s rectangle name.
쎲 Transform the Boolean variable or direct address into the ST format.
쎲 Open the Transition Condition editor.
GX IEC Developer Reference Manual 6 – 35
Programming in Sequential Function Chart Language Programming
d) Transition is already a Transition Condition
Open the Transition Condition editor.
e) Transition is a standard transition including a body in any language
쎲 You are asked:
“There is a body defined for this transition! Do you want to delete this body?”
– NO: nothing is done, exit function
– YES: continues
쎲 Delete the existing transition body.
쎲 Create a new transition: name=""; language = ST.
쎲 Open the Transition Condition editor.
The command Zoom Body
The command Zoom Body opens the Transition Condition editor if the corresponding transition is already a Transition Condition. Otherwise the appropriate editor will be opened (as before).
쎲 If the current transition is a valid device or variable, nothing will happen.
쎲 If the transition is empty (new definition), it depends on settings of the Transition
Conditions (Extras - Options - General Options - Transition Condition).
The command Zoom Into
The command Zoom Out works also in the Transition Condition editor. Changes will be stored to the database.
The command Zoom Out
The command Zoom Out works also in the Transition Condition editor. Changes will be stored to the database.
The command End Edit
The command End Edit behaves like Zoom Out.
The command List Operands
The command List Operands opens the dialogue Variable Selection, which can be called by means of the menu command, the toolbar icon, or by pressing the key F2 within the TC editor.
The command List Operators
The command List Operators opens the dialogue Function Block Selection, which can be called by means of the menu command, the toolbar icon, or by pressing the key SHIFT+F2 within the TC editor.
The command New variable
The command New Variable opens the dialogue Variable Selection in the NewVar mode.
This dialogue can also be called by pressing ALT+N.
6 – 36
MITSUBISHI ELECTRIC
Programming Programming in Sequential Function Chart Language
Example
Transition rectangle
Display
The transition rectangle display contains the beginning (if there is not enough space to display the complete Transition Condition) of the Transition Condition in brackets with a leading ‘=’.
‘...’ shows that there is not enough space to display the complete condition.
TC:
Transition Display:
(X10 AND X11) OR (aBool1 OR aBool2)
=[(X10 AND X11) OR ((aBoo...]
In the display carriage returns, line feed, and tabs will be replaced by spaces.
쑶
Edit field of the Transition name
When leaving the edit field of the Transition name, additional checks will be performed. There are the following situations:
a) A Transition Condition exists and has been replaced by a Boolean variable or address.
쎲 You are asked whether you want to delete the existing Transition Condition.
Fig. 6-31:
Confirmation of
Transition Condition deletion
– Yes:
– No:
Delete the corresponding ST Transition
Set the given variable into the Transition’s rectangle
Nothing will be done, exit function
b) A Transition Condition exists and will be replaced by an identifier not yet defined
쎲 You are asked whether you want to delete the existing Transition Condition.
Fig. 6-32:
Confirmation of Transition
Condition deletion
– Yes:
– No:
Delete the corresponding ST Transition
Set the given identifier into the Transition’s rectangle
Nothing will be done, exit function
GX IEC Developer Reference Manual 6 – 37
Programming in Sequential Function Chart Language Programming
Double-click behaviour
A double click on the Transition’s rectangle has the same effect as using the commands Zoom
Into or Zoom Body.
The double click opens the Transition Condition editor if the corresponding Transition is already a Transition Condition. Otherwise the appropriate editor will be opened.
If the current transition is a valid device or variable, nothing will happen.
If the transition is empty (new definition), it depends on settings of the Transition Conditions
(Extras - Options - General Options - Transition Condition).
Edit window
Fig. 6-33:
Edit window for Transition Conditions
The left upper corner of the edit window is located at the right upper corner of the transition rectangle.
The edit window has a maximum and a minimum size. Within this range the window is adapted to the current size of its content.
Syntax
ST Boolean expressions can be entered. All types of IEC 61131-3 ST expressions resulting in a Boolean value can be entered.
The following table shows the IEC 61131-3 ST operators and to their priority level.
Comments
2
3
Priority level Operation
1 Brackets
Function call
Exponentiation
Negation
4
Complement
Multiplication
5 Division
6
7
8
9
10
11
Modulo
Addition
Subtraction
Comparison
Equality
Inequality
Logical AND
Logical Exclusive OR
Logical OR
Operator symbol
( )
Fun( )
**
-
/
NOT
*
MOD
+
-
<, >, <=, >=
=
< >
AND, &
XOR
OR
Unary minus
Remainder of integer division
Binary minus
Tab. 6-6:
IEC 61131-3 ST operators
6 – 38
MITSUBISHI ELECTRIC
Programming Programming in Sequential Function Chart Language
It is also possible to enter only the pure expression in the SFC transition (ST Boolean expressions):
X1 AND X2
ST Boolean expressions are nameless. Therefore they are not displayed in the project navigator.
Navigator
Cut, Copy, Paste
Since the TC bodies are not visible for the user, there is no possibility to cut, copy, paste these bodies explicitly.
Cut, copy, and paste the complete SFC POU also include the TC bodies.
SFC UNDO
The SFC UNDO function handles the Transition Conditions in a similar way as standard transitions.
Transition body a) Blank transition before defining a new TC
Take the following steps:
햲 Delete the created ST body.
햳 Delete the internal SFC transition body.
b) Direct transition before defining a new TC
A direct transition can be TRUE or FALSE, a direct Boolean variable, or a direct Boolean address.
Take the following steps:
햲 Delete the created ST body.
햳 Delete the internal SFC transition body.
햴 Restore the old direct transition name.
c) Standard transition before defining a new TC
Take the following steps:
햲 Delete the created ST body.
햳 Delete the internal SFC transition body.
햴 Restore the old transition name.
GX IEC Developer Reference Manual 6 – 39
Programming in Sequential Function Chart Language Programming
Replace an existing TC a) Direct transition
To replace an existing TC by a direct transition,
햲 clear the name of the direct transition.
Remark
Step 1 is not implemented because this feature is not available when replacing a standard transition body.
b) Transition name
To replace an existing TC by a transition name,
햲 clear the name of the transition body name.
Remark
Step 1 is not implemented because this feature is not available when replacing a standard transition body.
Unused transitions
When leaving the SFC editor without saving the changes problems may occur.
In the following situations unused ST bodies will be left:
쎲 Replace a direct transition by a Transition Condition
쎲 Leave the SFC editor and cancel the saving of the changes
쎲 Open the SFC editor. The direct transition is displayed again, but the corresponding transition body still exists in the database
The situations described above are also valid for standard transition bodies, but standard transition bodies are visible for the user. You can delete unused transitions by yourself.
Since Transition Conditions are hidden in the navigator, it is not allowed to create unused ST bodies.
6 – 40
MITSUBISHI ELECTRIC
Programming Programming in Sequential Function Chart Language
Monitoring
Example 1
Example 2
Example 3
Example 4
Example 5
Example 6
Example 7
Example 8
What is monitored?
GX IEC Developer provides a monitoring feature splitting the Transition Conditions into several
Boolean expression parts monitored separately. The splitting is done by the Boolean operators, except for NOT (see evaluate in the following table). If a Boolean operator is included in an expression, the expression is split into two expression parts (one part on the left and one part on the right of the operator). For all parts this algorithm is used recursively, until no more Boolean operators can be found in any part. Brackets will be handled according to the arithmetic rules.
The Boolean operator NOT will be handled uniformly. NOT will be evaluated with the inverted expression if this is a single monitoring expression (it will be monitored separately). If the inverted expression cannot be monitored because it includes ignored operators for example, the complete expression part including NOT will not be monitored neither.
All parts will be searched for comparison operators (see evaluate in the following table). If a comparison operator is found, it will be compared with a Boolean value and monitored.
If an expression part includes any other operator, this expression part will be ignored and not monitored (see ignored in the following table).
Priority level
1
2
3
4
5
6
7
8
9
10
11
Operation
Brackets
Function call
Exponentiation
Negation
Complement
Multiplication
Division
Modulo
Addition
Subtraction
Comparison
Equality
Inequality
Logical AND
Logical Exclusive OR
Logical OR
Operator symbol
( )
Fun( )
**
-
/
NOT
*
MOD
+
-
<, >, <=, >=
=
< >
AND, &
XOR
OR
When monitoring handled
ignored ignored ignored
evaluate
ignored ignored ignored ignored ignored
evaluate evaluate evaluate separator separator separator
Tab. 6-7:
Priority levels of monitored operations
The following examples show how transitions are monitored. The underlined parts will be monitored as one Boolean value.
X1 AND X2 OR X3
(D1 < 0) OR ((D2 > 0) AND (D3 > 0))
X1 AND (X2 OR X3) AND ((D0 0) OR X3)
NOT (D1 < D2)
NOT ((D5 > 0) AND (D3 < 0))
NOT (D1 < D2) AND (D3 > D4 + D5)
(M1 AND M2) OR (M3 AND M4)
NOT M1 AND M2 OR M3 XOR M4
GX IEC Developer Reference Manual 6 – 41
Programming in Sequential Function Chart Language Programming
Display
There are three possible display modes: the edit mode, the online mode, and the monitoring mode.
a) Edit mode
Edit control
The edit control opens when the online mode is not active. When the online mode is closed, the edit control opens automatically.
See sections above
Fig. 6-34:
Edit mode
b) Online mode
The edit mode is closed. The content of the Transition Conditions is displayed using the standard background colour of the editor.
Fig. 6-35:
Online mode
6 – 42
MITSUBISHI ELECTRIC
Programming Programming in Sequential Function Chart Language
c) Monitoring mode
The edit mode is closed. The content of the Transition Conditions is displayed using the standard background colour of the editor. The state of the Boolean variables and direct addresses is displayed additionally.
Values which cannot be indicated completely within the window will not be monitored.
Fig. 6-36:
Monitoring mode
Starting or stopping the Transition Condition monitor automatically
Starting the Transition Condition monitor
The Transition Condition monitor starts automatically when the SFC body is monitored.
Stopping the Transition Condition monitor
The Transition Condition monitor stops when
쎲 the Transition Condition editor has been closed.
쎲 the SFC body monitor has been stopped.
쎲 the online mode has been left.
Multiple monitors
Only one Transition Condition monitor can be active per SFC editor. However, it is possible that more TCs can be monitored at the same time if they are included in different SFCs.
GX IEC Developer Reference Manual 6 – 43
Programming in Sequential Function Chart Language Programming
Value modification in the SFC TC editor
When an address or variable is double-clicked in a transition condition editor during monitoring, then the Modify Variable Value dialogue is opened, and it initializes with the name under the cursor.
Fig. 6-37:
Modify Variable Value
6 – 44
MITSUBISHI ELECTRIC
Programming
6.5.14
Programming in Sequential Function Chart Language
SV instruction for QnA
Definitions
SV program
SV table
PLC program for supervision (SV)
Table containing inputs for the SV program
General concept
An array of help memories includes the information when to start an SV and where the information is located in an SV table. If a Help Memory Cell is set to ON, a supervised output is set to
ON and the SV starts. All necessary supervision parameters are included in a relative place of the memory cell in the array. The index indicates the reference to an element in an SV table
(see below).
If the acknowledge Stop input does not get its expected value within the supervision time, a
TimeOut memory cell is activated.
M-cell
0 M1000
1 M1001
2 M1002
3 M1003
.
.
.
ON
998
999
Time
0 100
1 80
2 140
3 160
4
5
.
.
.
Stop
X56
XE2
X10
X8F
.
.
.
Out
Y200
Y10F
Y100
Y135
.
.
.
TimeOut
F600
M1700
M1504
F601
.
.
.
Margin
12
25
25
50
.
.
.
Help Memory Cells SV table in the PLC
Example: If the Run input of an OUT_SV function block is active, the according Help Memory
Cell (here M1002) is switched to ON, i.e. that the SV program fetches all data from line 2 of the
SV table. If the SV times out, the TimeOut memory cell (here M1504), is switched to ON. The values in the SV table are not coded correctly.
Besides F devices the TimeOut column can contain also the device values of other M memory cells, which can be used as trigger for other user program parts.
The Margin fields are reserved for future use.
Each register of the SV table contains only a value, i.e. no memory cell or pointer can be included. The possibilities to code SV table elements are described in section “Coding of the
SV table elements” (see page 6-49).
GX IEC Developer Reference Manual 6 – 45
Programming in Sequential Function Chart Language Programming
SV library
GX IEC Developer includes an SV library containing all necessary items for supervising:
쎲 OUT_SV, OUT_SV2 – OUT_SV6
Function blocks to activate outputs and start supervising stop inputs
쎲 SV
Supervising program
To enable the SV functionality in GX IEC Developer, the new library must be specified in the file
MMP703.INI and loaded project into an existing GX IEC Developer via Project - Other -
Update Libraries.
When creating a new project, use pre-packed projects already containing the User and the
Standard libraries for the specified CPU type. After the menu command Project - New ... has been executed, the file MMP703.INI is scanned automatically in order to check whether additional libraries must be included into the new project. You have the possibility to update the libraries of your new project.
Code generation for OUT_SV
At each step where an OUT_SV is used, the code generator of GX IEC Developer sets the according Help Memory Cell to ON to enable the supervision.
The GX IEC Developer code generator maintains an internal code generator SV table including information about all used supervisions. This table collects all static SV parameters during compiling. From the code generator SV table the SV table of the PLC is created and downloaded to the PLC when the program is transferred to the PLC. During online changes the internal code generator SV table and the PLC SV table are updated.
For the OUT_SV a predefined function block instance must be used. This is necessary because OUT_SV has three outputs which cannot be used together with a function. The same predefined function block instances should be used for different TimeOuts. It is also possible to define only one global OUT_SV function block instance and to use it at several locations.
The following table shows the possible parameters.
Name
Run
Stop
_Time
Margin
Out
T_O (* TimeOut *)
Type
BOOL
BOOL
INT
INT (constant)
BOOL
BOOL
Input range
Any Boolean expression
X, M, B
0 – 32767 (0,0 – 3276,7 sec) or a VAR_INPUT if it is used in an FB
0 (to disable teach in) / 12/ 25/ 50/ 100 %
Y, M, B
Any M or F address
Tab. 6-8:
Possible parameters for OUT_SV
For all parameters except
The parameter
Run
only a direct connection to a constant or a variable is allowed.
Stop
can also be used negatively. The parameters
Out
or
TimeOut
cannot be used negatively.
For the parameter
_Time
only a direct constant or a VAR_INPUT of a function block can be used.
6 – 46
MITSUBISHI ELECTRIC
Programming Programming in Sequential Function Chart Language
VAR_CONSTANT or VAR_GLOBAL_CONSTANT are not allowed to be constants. For a
VAR_INPUT code is produced, which writes the value to the SV table. For each variable a new line is inserted into the SV table to be independent of other entries using constants for the parameter
_Time
.
For the parameter
Margin
only direct constants are allowed. To be able to use OUT_SV in a macro FB with VAR_INPUT for the parameter constant is used.
Margin
, the code generator checks whether a
The parameter of OUT_SV cannot be used directly in other instructions, e.g.
InstOUT_SV.Margin
is not allowed.
ST
For the parameters Stop and Out all local variables, global variables, or direct addresses can be used if they meet the address range restrictions described in the section “
Coding of the SV table elements
For the output parameter
TimeOut
only M or F devices can be used. In this case direct addresses, global variables, or local variables are allowed. If any other device type is used for the
TimeOut,
an error is generated during compiling.
The following figure shows a code which has been programmed manually in an editor.
Fig. 6-38:
Sample programs for
OUT_SV
The second network shows an example in which stop has been negated (set with a double click in the OUT_SV box near the stop parameter).
Codes generated for the first network:
LD
AND
OUT
ANI
OUT
X0
X1
Help Memory Cell
X100
Y200
No interlocking is made when the Help Memory Cell is already activated.
It is not necessary to set a Help Memory Cell, because the Help Memory Cell is activated by the SV program. After the activation the value of the Help Memory Cell can change without influencing the SV program.
Codes generated for the second network:
LD
AND
OUT
AND
OUT
X0
X1
Help Memory Cell
X300
Y300
GX IEC Developer Reference Manual 6 – 47
Programming in Sequential Function Chart Language Programming
The SV parameters in the code generation SV table are updated for all networks during compiling.
For each Stop/ Out/ TimeOut combination a new line is added to the internal code generation
SV table. If a Stop/ Out/ TimeOut combination is already included in this table,
Time
and
Margin
must be the same. Otherwise an error is generated during compiling.
To allow several Stop/ TimeOut combinations to be used with the same
Time
and
Margin
additional OUT_SV function blocks can be used. They must be defined as new function blocks
, including their own names, because GX IEC Developer does not support extended output parameters. OUT_SV2 allows two Stop/TimeOut combinations, OUT_SV3 allows three combinations, etc.
For each Stop/ TimeOut combination the code generator does the same as for OUT_SV, but it uses the same Time and Margin for the SV table.
Example for OUT_SV6
6 – 48
Fig. 6-39:
Example for OUT_SV6
Generated codes:
LD
AND
OUT
:
X0
X1
Help Memory Cell 1
:
OUT
LDI
ORI
ORI
ORI
ORI
ORI
ANB
OUT
Help Memory Cell 6
X100
X20
M10
B2F
MotorOff
M20
Y200
For the parameter TimeOut output M and F devices can be mixed.
MITSUBISHI ELECTRIC
Programming Programming in Sequential Function Chart Language
Example
F devices and User Error file
If F devices are used as TimeOut parameters for OUT_SV, the SV will activate the F devices if the Stop input does not get its specified value within the specified time. Via Debug - User
Errors a list box can be opened in GX IEC Developer displaying the active F devices.
If the project directory includes the file USER_ERR.TXT, the project directory is scanned for user defined error texts. For this, the text lines in the file must have the following format:
[F Device Value] [Space or ‘,’ or Tab]1-n [Error text]
1 Error text for user error 1
10 Go to Motor 12 and check whether it is running
11, Robot 10 did not reach the target B
A line can include 260 characters maximum and the error text 255 characters maximum.
쑶
Interface of the SV program
To enable the supervision, assign the SV program to an task always running. It is not possible to include a predefined task in a library in GX IEC Developer. If you program some OUT_SV without assigning the SV program to a task, a warning will be generated.
The SV program uses fixed addresses. The fixed addresses will be defined as global variables in the SV library as a reference for the user that these addresses are reserved. They cannot be changed by the user. Internally these addresses will be used directly due to some restrictions of the MELSEC networks concerning symbolic programming and in order to have a quick base for testing. In a second step the SV program will be changed to symbolic programming.
Coding of the SV table elements
Name
Stop
Supervision Time
Teach In Margin
Out
TimeOut Memory Cell
Y
M
B
M
F
M
B
X
K
K
M
B
X
Type Offset (hex)
0
3000
6000
8000
B000
E000
0
2000
A000
0
8000
Input range
0
3000
6000
2FFF
5FFF
7FFF
8000
B000
E000
AFFF
DFFF
FFFF
0 - 32767
0
12/ 25/ 50/ 100
0
2000
A000
1FFF
8FFF
FFFF
0 7FFF
8000 FFFF
Tab. 6-9:
Coding of the SV table elements
-
-
1
1
1
Expected status
0
0
0
1
1
1
no Teach In
-
Number
12288
12288
8192
12288
12288
8192
8192
32768
24576
32768
32768
GX IEC Developer Reference Manual 6 – 49
Programming in Sequential Function Chart Language Programming
Additional menu commands
The additional menu commands
Extras - SV - Update Time
Extras - SV - Options
are enabled only when the SV library is present, i.e. when the SV library is part of the project.
The values which can be edited by the user are set in the dialogue Option.
Fig. 6-40:
SV Options
If the number of the Help Memory Cells is not a multiple of 32, it is adjusted to the next lower value which can be divided by 32. If a value for the number of the SV Help Memory Cells is entered, which is too high, it is adjusted automatically. The maximum value will result from the length of the SV table. The default value will be 160 = 5 x 32 blocks.
When compiling the project, the addresses of the specified Help Memory Cells are allocated and reserved in the system address range of the project. By this, these addresses will not be used directly anywhere else in the project.
The values of the SV Options are exported or imported respectively together with the PLC configuration.
All necessary inputs for the SV program will be set by GX IEC Developer via symbolic
VAR_GLOBAL_CONSTANTs in the SV library. The user cannot change the values of the constants.
Symbolic name
SV_HELP_START
SV_HELP_BLOCKS
Content set by GX IEC Developer
Start of SV Help Memory Cells (e.g. 1234 to start at M1234) Automatically calculated by GX IEC Developer.
Number of 32 bit blocks of SV Help Memory Cells
Tab. 6-10: Contents of symbolic constants
The constants will be updated when the user has changed the value in the dialogue SV
Options or when new addresses have been allocated by the compiler.
When SV_HELP_START or SV_HELP_BLOCKS are changed, the SV program and all GX
IEC Developer objects, which use OUT_SV – OUT_SV6, are set to Must be compiled.
6 – 50
MITSUBISHI ELECTRIC
Programming Programming Functions
6.6
NOTE
6.6.1
Programming Functions
Programming the header and body of a function is not different from programming a program
POU. You can program functions in the following editors:
쎲 Instruction List (IL)
쎲 Ladder Diagram (LD)
쎲 Structured Text (ST)
쎲 Function Block Diagram (FBD)
The two main characteristics of functions are that they output exactly one data element when they are processed and that they always deliver the same output values in response to the same input values. Functions do not have any memory, and although they can contain more than one data element (arrays) they can only output one data element. Functions are thus independent program blocks; they have the same functionality as normal programming instructions, and can be replaced and used in other program sections at will.
Each user-defined function uses one system label, irrespective of how often the function is called (
Using timers in functions
If you are not careful, programming timers in subprograms, functions and function blocks can lead to problems. You should always remember that once a timer has been triggered it just goes on counting independently, irrespective of whether the condition that triggered the branch to the subprogram, function or function block is still true or not. It is thus better to avoid using timers in this way if possible, and if you can’t avoid it you should make allowances for this behaviour in the code of your program.
GX IEC Developer Reference Manual 6 – 51
Programming Functions Programming
6.6.2
NOTE
Declarations
The first step in creating a function is to declare it as a program organisation unit.
Header
In the header you must declare all the variables used in the function. Function variables can be either of the type VAR, VAR_INPUT or VAR_CONSTANT. The function itself can be one of the data types (BOOL, INT, DINT, WORD, DWORD, TIME, REAL).
The variables declared in the header are also referred to as formal parameters.
Body
The body contains the program code to be performed on the variables declared in the header.
The result of the function must be explicitly assigned to the function name.
The procedure for creating a new function is described in section 4.8, ‘How to create new
objects’.
Formal parameters
The result is assigned to the function name
Fig. 6-41:
User created function block
6 – 52
MITSUBISHI ELECTRIC
Programming Programming Functions
6.6.3
NOTE
Calling functions in the text editor
All variables must be assigned when a function is called; the parameter list must be complete.
When you call a function in Instruction List language you must first load the first parameter into the accumulator with the Load instruction (LD). The next program line then contains the references to the function’s name, as the operator, and to the other variables declared in the header. When this statement is executed actual parameters – i.e. specific values – are passed to the remaining formal parameters defined in the header. The result of the function is stored in the accumulator.
Fig. 6-42:
Function call in text editor
NOTE
The value 10 is loaded into the accumulator. This is then followed by the function call FUN_1.
The value in the accumulator is added to Factor_A and multiplied by Factor_B. The result is stored both in D100 and the accumulator.
Please note that you must always assign the values to the variables in the correct order as dictated by the syntax!
Using the editing support function
햲 Position the cursor in the first column and enter the name of the function.
INSERT
햳 Press § and . The parameters are inserted automatically, with dummy variable question marks and the data type in the actual parameter positions.
LD ?STRING
INSERT ?STRING,
?INT
ST ?STRING
햴 Overwrite the dummy variable names with a direct address or a variable name.
GX IEC Developer Reference Manual 6 – 53
Programming Functions
6.6.4
Programming
Calling functions in the graphical editors
The same procedure is used for calling functions in Ladder Diagram and Function Block
Diagram.
How to call functions in the graphical editors
햲 Open the POU body
햳 Select Function Block in the Tools menu. This opens the Function Block Selection dialogue box.
햴 Select the required function’s name.
햵 Confirm with OK.
햶 The mouse pointer changes to a function ‘block’ symbol. Position it at the required location in the editing area and press
«. The graphical block representing the function is inserted at the pointer location. The names of the variables are shown at the function, inside the block representing the function. The name of the function itself is shown at the output, which is also inside the function ‘block’ symbol.
햷 Allocate actual parameters (outside) to the formal parameters (inside).
Fig. 6-43:
Function call in graphical editor
Actual parameters Formal parameters
6 – 54
MITSUBISHI ELECTRIC
Programming Programming Function Blocks
6.7
Programming Function Blocks
Programming the headers and bodies of function blocks is no different from programming normal program POUs. You can program function blocks with the following languages:
쎲 Instruction List (IL)
쎲 Ladder Diagram (LD)
쎲 Structured Text (ST)
쎲 Function Block Diagram (FBD)
Function blocks can have one or more outputs and can produce one or more different output values for the same input values. The results are stored after the function block has been processed, and these values are used the next time the function block is called. Function blocks must be instantiated before they can be called in a POU.
6.7.1
NOTE
Using timers in function blocks
If you are not careful, programming timers in subprograms, functions and function blocks can lead to problems. You should always remember that once a timer has been triggered it just goes on counting independently, irrespective of whether the condition that triggered the branch to the subprogram, function or function block is still true or not. It is thus better to avoid using timers in this way if possible, and if you can’t avoid it you should make allowances for this behaviour in the code of your program.
The instruction Timer_FB_M uses one Timer for each instance.
GX IEC Developer Reference Manual 6 – 55
Programming Function Blocks Programming
6.7.2
Example
NOTE
Declaration
The first step in creating a function block is to declare it as a program organisation unit.
Header
All the variables used in the function block’s code must be declared in the header. Variables in function blocks can be of the types VAR, VAR_IN_OUT, VAR_INPUT, VAR_OUTPUT,
VAR_CONSTANT, VAR_GLOBAL or VAR_GLOBAL_CONSTANT. The result of the function can be one of the data types (BOOL, INT, DINT, WORD, DWORD, TIME, REAL).
Body
The body contains the program code to be performed on the variables declared in the header.
Direct programming of hardware addresses is not permitted.
The function block COUNTER stores the duration of a process. The header contains declarations of three output variables (Hours, Minutes, Seconds), one input variable (Process) and one global variable (SecClck) that addresses relay M9032, which switches once per second.
The procedure for creating a new function block is described in section 4.8, ‘How to create
new objects’.
Header of the function block
Fig. 6-44:
Function block header
6 – 56
MITSUBISHI ELECTRIC
Programming
Body of the function block
Programming Function Blocks
Fig. 6-45:
Function block body
As soon as an input signal is registered the variable ‘Seconds’ is incremented once per second.
When the value of ‘Seconds’reaches 60 ‘Minutes’is incremented by 1 and ‘Seconds’is reset to 0.
When the value of ‘Minutes’ reaches 60 ‘Hours’ is incremented by 1 and ‘Minutes’ is reset to 0.
쑶
6.7.3
NOTES
Example
Instantiation
Function blocks cannot be called directly, they must be called as ‘instances’. When a function block is ‘instantiated’, an instance or copy of it is created in the header declaration table of the
POU under consideration. The instance is declared as a variable VAR, for which any identifier can be used. The ‘Type’ is the name of the function block.
You can make multiple instances of one function block. However, remember that each instance you create uses up one system label (
When using the macro code no label is required.
In this example, the COUNTER function block programmed above is instantiated in the MAIN program POU as PROCESS_TIME.
Fig. 6-46:
Instantiation example
GX IEC Developer Reference Manual
쑶
6 – 57
Programming Function Blocks Programming
6.7.4
Example
Calling function blocks in the text editor
You do not have to assign all the variables in the parameter list when you call a function block.
The old register values are used for those parameters not assigned in the call.
Function blocks are called with the following instructions
CAL
CALC
CALCN
(Call)
(CallConditional: conditional call)
(CallConditionalNot: negated conditional call)
Calling with a list of input parameters:
Syntax:
CAL Instance Name ( Formal parameter := Actual parameter , ...)
The instance name of the function block is PROCESS_TIME. In this example, the actual parameters X0, D1, D2 and D3 are assigned to the formal parameters ‘Process’, ‘Seconds’,
‘Minutes’ and ‘Hours’.
CAL Process_Time(Process:=X0, Seconds:=D1, Minutes:=D2, Hours:=D3)
쑶
Call with input parameter load/store:
Syntax:
LD
ST
CAL
Actual parameter
Formal parameter
FBName()
6 – 58
MITSUBISHI ELECTRIC
Programming Programming Function Blocks
Example
The instance name of the function block is PROCESS_TIME. In this example, the actual parameters X0, D100, D200 and D300 are assigned to the formal parameters ‘Process’,
‘Seconds’, ‘Minutes’ and ‘Hours’.
LD
ST
LD
ST
LD
ST
LD
ST
CAL
X0
Process
D100
Seconds
D200
Minutes
D300
Hours
Process_Time()
쑶
Using the editing support function
햲 Position the cursor in the first column and enter the CAL instruction.
햳 Position the cursor in the second column and press .
햴 Select the function block instance (FB_INST in the example) from the Variable
Selection dialogue box.
CAL FB_INST
햵 Press § and . The parameters are inserted automatically. The names of the internal function block variables are entered as the formal parameters. Dummy variable question marks and the data type are displayed in the actual parameter positions.
CAL FB_INST(IN1:=?BOOL,
IN2:=?BOOL,
IN3:=?BOOL)
햶 Overwrite the dummy names with either a direct address or a variable name. Tip: If you select the dummy name (?BOOL) and press
you can select the variable directly from the list displayed. Select Apply to enter the variable.
CAL FB_INST(IN1:=X1,
IN2:=VAR_EIN1,
IN3:=VAR_EIN2)
GX IEC Developer Reference Manual 6 – 59
Programming Function Blocks Programming
6.7.5
Calling function blocks in the graphical editors
How to call function blocks in the graphical editors
햲 Open the body of the program POU in which you wish to call the function block.
햳 Select Function Block in the Tools menu. This opens the Function Block Selection dialogue box.
햴 Select the required function block’s name and confirm with OK.
햵 Move the mouse pointer to the desired position in the editing window and press the
Space Bar to insert the function block.
햶 Press for a list of the instance names declared in the header.
햷 Select the appropriate instance name and confirm with OK. The name is then used as the identifier for the function block instance.
햸 Terminate the procedure by pressing «.
Fig. 6-47:
The names of the formal parameters are shown in the function block.
The function block type is
COUNTER, the instance name is
‘Process_Time’ (
Þ
Header).
Formal parameters
Actual parameters
햹 Assign the actual parameters (outside) to the formal parameters (inside).
6.7.6
NOTE
6.7.7
Multiple use of a single instance
You can use the same instance of a function block in several different places within a POU, or, if it is defined globally, in several different places within the same PLC program.
If the EN of an FB or an FUN is zero, the output is not defined.
Combine several steps and transitions to create a macro
You can combine selected ranges in the SFC body and define them as macros.
This places all the steps and transitions within one Macro. In complex SFC programs, macros facilitate control and make it easier to keep track of the sequence structure.
Select the desired steps and transitions in the SFC body and call the menu command Edit
Macro. The selected area is then automatically redused to one macro. To return this step you call the menu command Edit Zoom Macro.
A macro is a “mini program” that is accessible for use in your project.
It is important to understand that macros are
not
subprograms – subprograms are routines that only exist once within your main program and are accessed and executed by performing a jump.
In contrast, macros are simply “reused code” that become part of the main program. They do not reduce the number of steps in a program, they just make programming easier.
6 – 60
MITSUBISHI ELECTRIC
Programming
6.7.8
Programming Function Blocks
Execution of Function Blocks
Function blocks can be executed in different ways:
쎲 Macrocode execution
쎲 MC-MCR execution
쎲 Use with EN/ENO
The execution mode is selected in the Function Information dialogue box.
Fig. 6-48:
Function block information
How to set the execution option
햲 Select the function block in the Project Navigator window.
햳 Display the Function Information dialogue box by pressing ¦«.
햴 Activate the check box. The Use MC-MCR option can only be activated when the other two options have already been activated.
This does not make any changes to instantiation and the programming of instances in the various programming languages.
GX IEC Developer Reference Manual 6 – 61
Programming Function Blocks Programming
Macrocode execution
쎲 Standard execution: The function block is called via a system label
쎲 Macrocode execution: The function block is expanded internally
With Macro Code
No internal system labels are needed to execute a function block instance.
Consequence
: The number of function blocks you can use is only limited by the size of the PLC memory as function blocks are independent of system labels.
User-oriented execution of the function block
No restrictions on the handling of timers and coils within the function block.
Without Macro Code (standard execution)
Each instance uses internal system labels (pointers).
햲
Consequence: Since the number of available system labels is limited (FX: 128, A: 256, Q: 1024) you cannot use more than a theoretical limited number of function blocks. In practice this number is even smaller as system labels are also required for other internal processes.
Implementation of the function block construct in conformity with the
IEC 61131-3 standard
Restrictions on the handling of timers and coils within the function block (subroutines).
Tab. 6-11: Macrocode execution
햲
To set the system labels parameter select Extras - Options and then click on System Vari-
ables (
Fig. 6-49:
System Variables
The maximum permitted number of system labels
(internal pointers) is limited by the used
PLC CPU.
Macrocode execution, MC-MCR execution, Use with EN/ENO
The function blocks FB_1 through FB_5 and the corresponding instances i_FB_1 through i_FB_5 show the different execution possibilities.
6 – 62
MITSUBISHI ELECTRIC
Programming
The function block
Use of the function block
Programming Function Blocks
Fig. 6-50:
Function block for macrocode execution
Fig. 6-51:
Function block instance
GX IEC Developer Reference Manual 6 – 63
Programming Function Blocks Programming
Macrocode execution options
Macro
MC-MCR
EN-ENO
Generated
Code
Instance
(no macro)
System labels
Behaviour of:
- Timers
- Counters
- Outputs
FB_1
NO
NO
NO
LD X10
OUT M4096
LD X11
OUT M4097
LD SM400
CALL P2048
LD SM400
MOV D6144
D10
LD M4096
AND M4097
INCP D6144
RET
1 System label
(no macro)
The function block is always executed. The timers, counters and outputs are thus controlled by the program.
FB_2
YES
FB_3
NO
NO
NO
LD X20
AND X21
INCP D20
No system labels
(macro)
NO
YES
LD M3
OUT M4098
AND X30
SET M4099
LD M4098
ANI X30
RST M4099
LD M4098
AND X31
SET M4100
LD M4098
ANI X31
RST M4100
LD M4098
OUT M4101
CALL P2049
LD M4101
OUT M31
LD SM400
MOV D6145 D30
LD M4099
AND M4100
INCP D6145
RET
1 System label
(no macro)
The function block is always executed. The timers, counters and outputs are thus controlled by the program.
FB_4
YES
NO
YES
LD M4
OUT M41
LDI M4
CJ P2050
LD X40
AND X41
INCP D40P2050
FB_5
YES
YES
YES
LD M5
OUT M51
MC N0
M4103
LD X50
AND X51
INCP D50
MCR N0
The function block is only executed if the EN input is set.
This means that the timers, counters and outputs retain their status from the last execution. Timers continue to run.
The status of counters, accumulator/retenti ve timers and outputs in OUT instructions is preserved.
1 System label
(EN/ENO and jump)
No system labels
(macro and
MC/MCR)
The function block is only executed if the
EN input is set.
This means that the timers, counters and outputs retain their status from the last execution. Timers continue to run.
The status of counters, accumulator/reten tive timers and outputs in OUT instructions is preserved.
The statuses of the devices are reset:
- Timer: Count value reset to 0, contacts remain off
- Retentive timers and counters: count value and input contact status preserved, output contact is reset
- Devices in OUT instructions: outputs are reset
- Devices in SET,
RST, SFT instructions: current status preserved
Tab. 6-12: Macrocode execution options
6 – 64
MITSUBISHI ELECTRIC
Programming
6.7.9
Programming Function Blocks
Global Function Blocks
Function blocks allow global instancing, so that the same instance can be used in different program organisation units.
How to create a global instance
햲 Create a program organisation unit as a function block (in our example: MAIN).
햳 Create an instance (Main_Instance1) of this function block (MAIN) in the Global
Variable List.
Fig. 6-52:
Created instance
햴 Call up the function block in the body, and allocate to it the name of the instance.
Fig. 6-53:
Function block allocated to instance
GX IEC Developer Reference Manual 6 – 65
Programming Data Unit Types Programming
6.8
NOTE
Programming Data Unit Types
Data unit types (DUT) are structured, derived data types containing a collection of variables which can be of different data types. Data unit types can be declared as global or as local variables.
Data unit types can only be used in the IEC editors. DUT components or arrays can not be used in MELSEC IL
6.8.1
Example
Declaration
Data unit types must be defined in the DUT_Pool.
All the variables in the DUT structure must be declared in a special declaration table. After this you must then create one or more instances of the data unit type in the global variables declaration table.
How to declare a data unit type
햲 In the Object menu select New, then select Data Unit Type.
햳 Enter a name for the new DUT (max. 32 characters) and confirm with OK. The name of the new DUT is displayed in the DUT_Pool of the Project Navigator window.
햴 Double-click on the name of the new DUT in the Project Navigator window to open its special declaration table.
햵 Enter a name (identifier) for the variable in the first field.
햶 Select the data type for this variable in the second field.
햷 The default initial value (Initial) is added automatically. If you wish, you can also enter an optional comment for the variable.
햸 Repeat steps 햲 – 햷 until all the variables of the data unit type are defined.
The following example shows the creation of a data unit type called SiloType. The variable collection of SiloType contains two variables of the type INT and one variable of the type
BOOL.
햲 Enter the following lines in the declaration table for the data unit type:
Fig. 6-54:
Declaring variables of a data unit type
햳 Save your entries.
쑶
6 – 66
MITSUBISHI ELECTRIC
Programming
6.8.2
Programming Data Unit Types
Use of the DUT as global variable
How to declare the DUT
햲 Double-click on Global_Vars in the Project Navigator window.
햳 Enter the following lines in the global variables declaration table:
Example
Fig. 6-55:
Declaring the data unit type as global variable
Silo1 and Silo2 are the names of the variable of data type Silo_Type. Since the elements in type SiloType can have different data types the address assignment is handled automatically by the PLC, and no default initial values are shown.
You have created a Data Unit type called SiloType. Two variables of the type SiloType,
Silo1 and Silo2, have now been declared in the global variables list. The structure of both is identical, so to reference the individual variables of each DUT you only needs to prefix their names with the name of the respective global variable.
In Silo1 the values for the temperature and volume variables are determined by the contents of registers D0 and D1, in Silo2 by D10 and D11. In Silo1 the Emergency Off (EmergOFF variable) switch is controlled by the status of input X0, in Silo2 by input X1.
The variables are stored in the Global Variable List. If you apply an element of an instance of a
DUT or FB (e. g. Motor.Status) from the Global Variable List to an editor via the Variable
Selection dialogue, the corresponding DUT or FB is automatically inserted in the header of the editor. Like for simple data types the library <Global Variables> must be selected in the
Variable Selection dialogue.
Instruction List:
SILO1
LD
ST
LD
ST
LD
ST
D0
Silo1.Temperature
D1
Silo1.Volume
X0
Silo1.EmergOff
SILO2
LD
ST
LD
ST
LD
ST
D10
Silo2.Temperature
D11
Silo2.Volume
X1
Silo2.EmergOff
GX IEC Developer Reference Manual 6 – 67
Programming Data Unit Types
Ladder Diagram and Function Block Diagram
:
Programming
Fig. 6-56:
Ladder Diagram and Function Block Diagram
In the Ladder Diagram version of the example a function block of the type ‘Monitoring’ has been programmed for assigning the register values and the Boolean input to the elements of the DUTs. Two separate instances
(Silo_1 and Silo_2) of this function block were then created for the two silos.
쑶
Define direct addresses for data unit variables
The GVL has been extended to define addresses for all elements of a data unit variable. Not defined addresses are handled by the system.
Appearance and handling
In the GVL data unit variables will display their IEC and Mitsubishi address fields in controls similar to push buttons. On these controls the elements for which an address is defined will be displayed in the form ‘element: address’.
Fig. 6-57:
Control elements of data unit types
6 – 68
MITSUBISHI ELECTRIC
Programming Programming Data Unit Types
To view all definitions at once (if more than one definition is available), DUT entries in the GVL can be expanded by double-clicking the row number field.
Fig. 6-58:
Expanded DUT entries in the GVL
Editing
It is not possible to edit the addresses directly in the GVL. To edit the EC and Mitsubishi addresses, click on a DUV’s IEC or Mitsubishi address field. Then a separate dialogue (application modal) will appear and you can edit the addresses for each DUV element.
Fig. 6-59:
Opened editing dialogue for data unit variables
After you have selected an element you can edit this element like in other address fields in the
GVL (e.g. by. double clicking or pressing the space key).
When the two edit fields are displayed, the focus can be moved between them by clicking on one of the fields or pressing the TAB key. By pressing ENTER or clicking outside of the edit fields the editing will be finished and the modifications accepted. By pressing ESC the editing will also be finished, but the modifications are cancelled.
If you activate the Automatic filling checkbox, when entering a address all variables of the same type that are not yet addressed will be addressed automatically.
MELSEC Q/QnA only:
If the function Automatic filling is activated the additional function All types is available.
If you activate the All types function, when entering an address all addresses of all variable types are filled automatically.
For timers and counters the All types function is not available, addresses of these types are not filled automatically neither.
GX IEC Developer Reference Manual 6 – 69
Programming Data Unit Types
6.8.3
Programming
Use of the DUT as local variable
Data unit types can also be passed directly as variables:
– As input and output parameters in function blocks
– As input parameters in functions
Create the Control function block
The function block processes the input variables and passes the results to the output variables. The input variables IN_Temperature, IN_Volume and IN_EmergOff are declared in the header, along with the output variable Silo_Output. Silo_Output is declared as the data unit type Silo_Type.
Fig. 6-60:
Declaring variables for the control function block
Calling the Control_Use function block and passing the data unit type directly as an output parameter
The function block Control is called in the program organisation unit Control_Use, creating the instance Silo_FB_1.
The input variables of the function block obtain their values from devices D0, D1 and X0
.
The output variables of Silo_Output are passed to the data unit type Silo_DUT_1.
Fig. 6-61:
Control function block
6 – 70
MITSUBISHI ELECTRIC
Programming Programming Arrays
6.9
Programming Arrays
An array is a collection of variables of the same data type. GX IEC Developer supports arrays with up to a maximum of three dimensions.
Arrays are only supported in the IEC editors.
NOTE
6.9.1
Example
Declaration
Arrays are declared in the header of the program POU. They can be declared as local or global variables.
This example shows the definition of a one-dimensional array called ArrSingle with three elements of the type INT, and a two-dimensional array called ArrDouble with three elements of the type INT in the first dimension and five elements of the type INT in the second dimension.
햲 Open the header of a POU.
햳 Add a new line to the table with the following entries:
Fig. 6-62:
Declaring arrays in the program header
VAR: Definition of the array as a local variable in the program organisation unit ‘P_12’.
ArrSingle/ArrayDouble: Names of the arrays.
ARRAY [0..2] OF INT: The one-dimensional array has three elements (0 – 2) of the type integer (INT)
ARRAY [0..2, 0..4] OF INT: This array is two-dimensional. The second dimension is separated by a comma between the braces. In this example the first dimension of ArrDouble has three elements (0 – 2) and the second dimension has five elements (0 – 4).
3(0): Number of elements (3) with the default value 0 (0)
15(0): Number of elements (3 x 5 = 15) with the default value 0 (0)
쑶
GX IEC Developer Reference Manual 6 – 71
Programming Arrays Programming
6.9.2
Example
Calling
Instruction List:
쎲 One-dimensional arrays
LD
ST
Actual parameter
Array Name [ Element ]
쎲 Two-dimensional arrays
LD
ST
Actual parameter
Array Name [ Element of 1st Dimension ,
Element of 2nd Dimension ]
1
0
2
3
4
A two-dimensional array called ArrDouble has been defined with three elements in the first dimension and five elements in the second dimension.
The data registers D0 and D1 are assigned to the following elements:
D0:
D1:
Position 1 in the first dimension I, position 2 in the second dimension
II
Position 2 in the first dimension I, position 3 in the second dimension
II
II
Fig. 6-63:
Two-dimensional array:
"ArrDouble"
D1
D0
I
0 1 2
Instruction List:
LD
ST
LD
ST
D0
ArrDouble[1,2]
D1
ArrDouble[2,3]
Ladder Diagram and Function Block Diagram:
Fig. 6-64:
Ladder and Function Block Diagram for arrays
쑶
6 – 72
MITSUBISHI ELECTRIC
Programming
6.9.3
Programming Arrays
Accessing an Array of BOOL as 16 or 32 bit Data Type
For a global or local Array of BOOL variable the first elements of the array could be accessed as WORD/ INT or as DWORD/ DINT by using a prefix before the name of the variable.
Fig. 6-65:
Example for declaring ArrBool ARRAY [1..32] OF BOOL
The prefix Kn can be used to access the array elements in groups of 4 bit.
n can be 1 - 8:
쎲 K1ArrBool
쎲 K2ArrBool accesses the array elements 1 - 4 as WORD or INT accesses the array elements 1 - 8 as WORD or INT
쎲 K3ArrBool
쎲 K4ArrBool
쎲 K5ArrBool
쎲 K6ArrBool
쎲 K7ArrBool
쎲 K8ArrBool accesses the array elements 1 - 12 as WORD or INT accesses the array elements 1 - 16 as WORD or INT accesses the array elements 1 - 20 as DORD or DINT accesses the array elements 1 - 24 as DORD or DINT accesses the array elements 1 - 28 as DORD or DINT accesses the array elements 1 - 32 as DORD or DINT
To access the first elements of an Array of BOOL in a DUT the prefix Kn must be used before the name of the array member, e.g. as MyDUTVar.K4ArrBool.
GX IEC Developer Reference Manual 6 – 73
Programming Timers and Counters
6.10
6.10.1
Programming Timers and Counters
Programming
TIMER and COUNTER Functions
The timer and counter functions are stored in the manufacturer library.
Timer Functions Counter Functions
TIMER_M
TIMER_VALUE_M
TIMER_START_M
COUNTER_M
COUNTER_VALUE_M
COUNTER_START_M
Operands
Normal timers/counters and extended timers/counters
Extended timers/ counters only
TIMER_H_M -
MELSEC Q/QnA series’ high-speed timer
Action
Pass set point value and call (start) timer/counter
Pass set point value
Call (start) timer/counter
Pass set point value and call (start) timer
Set timer intervals by parameters
Tab. 6-13: TIMER and COUNTER functions
Timers and counters always have the following four elements:
Set point value
Actual value
Output coil
Input contact (status)
Timer
TValue
TN
TC
TS
Counter
CValue
CN
CC
CS
Tab. 6-14: TIMER and COUNTER elements
NOTE
NOTE
The use of the various functions is illustrated below using a timer as an example. Counters are used in exactly the same way.
The TIMER_M function
A detailed example of the use of the TIMER_M function is provided in the Beginner’s
Manual.
Fig. 6-66:
TIMER_M
Use of the normal timer TC20
6 – 74
Use of the extended timer TC256
The TIMER_M function both passes the set point value and starts the timer TC (TCoil). The set point value is passed to TValue. With normal timers the set point value is passed directly. With extended timers the passed set point value is assigned to the timer and the set point value register (see below).
MITSUBISHI ELECTRIC
Programming Programming Timers and Counters
The TIMER_VALUE_M and TIMER_START_M functions
Using TIMER_VALUE_M and TIMER_START_M together provides exactly the same functionality as TIMER_M. The only difference is that the parameter passing and timer start operations are handled separately, which makes it possible to use them at different points in the PLC program. TIMER_VALUE_M and TIMER_START_M can only be used with the extended timers, and you must define the set point values registers for the extended timers.
Fig. 6-67:
TIMER_VALUE_M
Passes the reference value to the extended timer
TC256
TIMER_START_M
Starts timer TC256
6.10.2
Defining the reference value registers for extended timers and counters
You must always define and set a number of parameters when you use timers or counters. See
Section 2.9.6 System Variables for the setting of Timer and Counter.
TIMER and COUNTER Function Blocks
A selection of new standard function blocks are provided for programming local timers and counters. The system automatically uses free timers and counters from the system range.
Advantages
: No direct timer and counter addresses are required. You can create any number of instances – depends on the number of system timers – with different timers from just one function block.
The following function blocks are provided:
Comment Function Blocks
TIMER_10_FB_M
TIMER_100_FB_M
TIMER_CONT_FB_M
TIMER_HIGH_FB_M
TIMER_LOW_FB_M
TIMER_CONTHFB_M
COUNTER_FB_M
Meaning
10-ms-Timer
100-ms-Timer retentive timer high-speed timer low-speed timer retentive high-speed timer counter
Tab. 6-15: TIMER and COUNTER Function Blocks
MELSEC Q/QnA series only
MELSEC Q/QnA series only
MELSEC Q/QnA series only
GX IEC Developer Reference Manual 6 – 75
Programming Timers and Counters Programming
MELSEC Q/QnA series’ timers
The timers will act as high-speed or low-speed timers when they are activated by the appropriate instructions in the PLC program.
The timer intervals for the high-speed and low-speed range can be set in the PLC Setup dialogue box
(Þ page 5-50). In order to be compatible to A series projects, the function blocks
TIMER_10_FB_M and TIMER_100_FB_M are available in the MELSEC Q/QnA series as well. In a MELSEC Q/QnA series project they are the same as the function blocks
TIMER_HIGH_FB_M and TIMER_LOW_FB_M. But in this case, they are no longer 10-ms and
100-ms timers. Instead the timer interval set by the parameters is valid.
MELSEC A/AnS
TIMER_10_FB_M
TIMER_100_FB_M
MELSEC Q/QnA
TIMER_HIGH_FB_M
TIMER_LOW_FB_M
Comment
For the MELSEC Q/QnA series, it is not the intervals 10 ms and 100 ms which are valid, but the timer interval set by the parameters.
Tab. 6-16: MELSEC Q/QnA timers
Defining the system range
You must define the system range before attempting to use local timers or counters. The system then automatically selects a free timer or counter from this range. A compile error will be displayed if you try to use these new function blocks without previously defining the corresponding system range.
햲 Open the System Variables dialogue box (Extras – Options – System Variables).
Fig. 6-68:
System timer
System counter
햳 Define the necessary system range in the System Timers or System Counters fields.
This disables access to these addresses by other applications using direct addressing.
6 – 76
MITSUBISHI ELECTRIC
Programming Programming Timers and Counters
Instantiation
The use of these new function blocks is illustrated below using a 10 ms timer as an example.
햲 Declare the following variables in the header:
Fig. 6-69:
TIMER_XYZ is the instance of function block TIMER_10_FB_M
Timer start address
햳 Select function block TIMER_10_FB_M in the body.
Fig. 6-70:
Selecting the timer function block
The timer function block has the following input and output variables:
Fig. 6-71:
The timer function block TIMER_10_FB_M for 10 msec timers
TIMER_10_FB_M for 10-ms-Timer
Designation in the Function
Coil
Preset
ValueIn
ValueOut
Status
Coil
Set point value
Initial value
Actual value
Output contact
Meaning
Activation condition for the timer process
(Normally: 0)
➜ Note
The output contact is set when execution of the function block is complete.
Tab. 6-17: Timer function block designations
GX IEC Developer Reference Manual 6 – 77
Programming Timers and Counters Programming
햴 Assign the instance names defined in the header to the function block and allocate the necessary input and output variables.
Fig. 6-72:
Instance TIMER_XYZ of function block
TIMER_10_FB_M
NOTES
If you do not need one of the parameters for your application, e.g. ValueIn in the example, you can simply leave the contact unassigned. In this case, no program code will be generated.
For MELSEC FX series controllers the ValueIn parameter must be left unassigned!
6 – 78
MITSUBISHI ELECTRIC
Programming
6.11
The EN input and ENO output
The EN input and ENO output
Some programming instructions have an EN input and an ENO output in addition to the normal input and output variables. These instructions are identified in the standard library by the suffix
_E, e.g. ABS_E, BCD_TO_DINT_E . The functions in the manufacturer library do not have this suffix as they are all automatically provided with an EN input and an ENO output.
Functionality
The EN input controls the execution of the instruction.
There are several different ways to connect the EN input:
쐃
쐄
쐇
쐄
쐋
쐄
쐏 쐏
Fig. 6-73:
Different EN input connections
Item
�
�
�
�
�
Description
Direct connection of the EN input to the power bar at the left (LD only). The EN input is then always on and the instruction is always executed. When ADD_E is used like this it will produce exactly the same result as ADD without the EN input.
Link the EN input to a Boolean input variable. The instruction is then only executed when Variable_1 is active.
Connect the Boolean result of a an operation to the EN input. The instruction is then only executed when the result of the operation is TRUE.
Connect the EN input to the ENO output of the preceding instruction. The three instructions are then only executed when Variable_1 is active.
The ENO output does not have to be connected; it can be left unconnected if it is not needed.
Tab. 6-18: EN input items
GX IEC Developer Reference Manual 6 – 79
The EN input and ENO output
6.11.1
Programming
Execution with and without EN and ENO
Fig. 6-74:
User-written function WITH_EN_ENO:
With EN input and ENO output
User-written function WITHOUT_EN_ENO:
Without EN input and ENO output
User function WITH_EN_ENO
Execution of the function is controlled by relay M4 (when the input EN is processed).
M4 = 1 (TRUE):
– The function is executed.
– The result of the operation is written to D56.
– A new value is always written to D56.
M4 = 0 (FALSE):
– The function is not executed.
– No new value is written to D56. The value stored in D56 remains unchanged, it is not reset.
User function WITHOUT_EN_ENO
– The function is executed continuously.
– The result of the operation is written to D57.
– A new value is always written to D57.
6 – 80
MITSUBISHI ELECTRIC
Guided Ladder Editor
7 Guided Ladder Editor
7.1
Main Features
The following are the main features of the Guided Ladder Editor:
Implementation of an additional programming mode, Guided Mode.
쎲 Guided ladder circuit editing
쎲 Character Mode programming
쎲 Auto Comment feature
쎲 Ladder Editing Settings
Enhancement for the ease of ladder programming
쎲 Additional functionalities
쎲 User-friendly hotkeys
쎲 Enhanced program component variable name display
Each item of the main features is explained in detail in the following sections.
Main Features
GX IEC Developer Reference Manual 7 – 1
Main Features
7.1.1
Guided Ladder Editor
Guided Mode
The Guided Mode is an additional ladder-programming mode considering the possibility of programming mainly using the keyboard, and to reduce the mouse operations.
Guided Editing (Guided ladder circuit editing), Character Mode (Character programming mode) and Auto comment functions are collectively known as Guided Mode and Guided
Mode is just a name for the new ladder circuit-editing mode.
Guided Mode can be accessed from the following menu:
�
Fig. 7-1:
Menu Guided mode
No.
�
�
�
�
�
�
Explanation
Guided Mode
Guided editing
Overwrite Mode
Insert Mode
Line Mode
Auto Comment
Tab. 7-1:
Explanation for Fig. 7-1
�
�
�
�
�
7 – 2
MITSUBISHI ELECTRIC
Guided Ladder Editor Main Features
NOTE
The circuits created in Select Mode or Inter connect Mode are not affected when the user changes the current editing mode to Guided Mode.
The circuit created in Select Mode or Inter connect Mode can be edited in Guided Mode.
Character Mode is an internal functionality of Guided Mode and it cannot be accessed directly from the menu. But, Guided Editing and Auto Comment can be accessed from the user menu items.
Guided Editing and Auto Comment can also be accessed using their hotkeys and menu short cuts.
The following are the menu items and hotkeys related to Guided Mode.
7
8
9
4
5
6
No.
1
2
3
Menu Item
[Tools]-[Guided Mode]- [Guided Editing]
[Tools]- [Guided Mode]- [Insert Mode]
[Tools]- [Guided Mode]-[Line Mode]
[Tools]-[Guided Mode]-[Auto Comment]
[View]-[Colors]-[Overwrite Mode Cursor]
[View]-[Colors]-[Insert Mode Cursor]
[View]-[Colors]-[Line Mode Cursor]
[View]-[Colors]-[Cursor Fill]
[Tools]-[Network Elements]-[Delete Line]
Hotkey
CTRL+G
INSERT
CTRL+L
CTRL+SHIFT+A
—
—
—
—
CTRL + SHIFT + DEL
Tab. 7- 2:
Menu items for Guided mode
7.1.2
Guided Editing Modes & Cursors
There are 3 types of Guided Editing Modes.
Insert Mode
Inserts a program component when Insert key is activated.
Overwrite Mode
Overwrites an existing program component when Insert key is not activated.
Line Mode
Draws connecting line between program components and handles the function block placement in a network.
GX IEC Developer Reference Manual 7 – 3
Main Features Guided Ladder Editor
The Guided Editing Modes and their associated cursors are as follows:
a) Normal cursor or Overwrite Mode cursor
The Normal cursor is a red (RGB = 255, 0, 0 by default) rectangle of 5 Grids of width and 4
Grids of height. The color of the cursor can be changed using the View - Colors - Overwrite
cursor menu. The View - Colors - Overwrite Cursor will display a color selection dialogue same as the dialogue for changing the color of the Grid or Background in the previous versions of GX IEC Developer.
�
�
�
Fig. 7-2:
Normal cursor
No.
Explanation
�
�
�
5 Grids
4 Grids
Thickness of the cursor line is 4 Pts.
Tab. 7-3:
Explanation for Fig. 7-2
b) Insertion cursor or Insert Mode cursor
The Insertion cursor is a blue (RGB = 0, 0, 255 by default) rectangle of 5 Grids of width and 4
Grids of height. The color of the cursor can be changed using the View - Colors - Insert
cursor menu. The View - Colors - Insert Cursor will display a color selection dialogue same as the dialogue for changing the color of the Grid or Background in the previous versions of GX
IEC Developer.
�
�
�
Fig. 7-3:
Insertion cursor
No.
Explanation
�
�
�
5 Grids
4 Grids
Thickness of the cursor line is 4 Pts.
Tab. 7-4:
Explanation for Fig. 7-3
7 – 4
MITSUBISHI ELECTRIC
Guided Ladder Editor Main Features
The Grid cursor is a minimized form of the Normal cursor or Overwrite cursor
.
When the Tools - Guided Mode - Line Mode menu item is selected, the Grid cursor will appear at the top left corner of the current cursor position of the Normal cursor
.
�
�
Fig. 7-4:
Grid cursor
�
No.
Explanation
�
�
1 Grid
Thickness of the cursor line is 2 Pts.
Tab. 7-5:
Explanation for Fig. 7-4
c) Grid cursor or Line Mode cursor
The Grid cursor is a green (RGB = 0, 255, 0 by default) square of 1 Grid size on each side. The color of the cursor can be changed using the View - Colors - Grid cursor menu. The View -
Colors - Grid Cursor will display a color selection dialogue same as the dialogue for changing the color of the Grid or Background in the previous versions of GX IEC Developer.
� �
Fig. 7-5:
Grid cursor in Normal cursor
No.
Explanation
Grid cursor
Normal cursor area
Tab. 7-6:
Explanation for Fig.7-5
NOTE
The Normal cursor or Overwrite cursor will appear on the screen but it cannot be used when Grid cursor is displayed.
In the following sections the word “Cursor” implies that the Normal or Insertion cursor is used. It is not applicable to Grid Cursor if not mentioned explicitly.
Clicking a different location in the network can also move the cursor and it is applicable to all kind of cursors used in Guided Mode.
Displaying and hiding the cursor raster is possible using the View - Grid Menu.
The Grid menu can enable or disable both the Grid and Cursor raster.
GX IEC Developer Reference Manual 7 – 5
Main Features Guided Ladder Editor
Behaviour of Grid Cursor
5
6
9
Key
Arrow keys
0
Delete
Operation
Moves the Grid cursor according to the Up, Down, Left, Right arrow key pressed.
Draws a vertical line at the left side of the Grid cursor.
Draws a horizontal line at the bottom of the Grid cursor.
Places an input variable of a FB at the left side of the Grid cursor.
Places an input variable of a FB at the right side of the Grid cursor.
Deletes horizontal or vertical line that exactly fits with the size of Grid cursor
Tab. 7-7:
Behaviour of Grid Cursor
Cursor movements & Keyboard shortcuts
The normal cursor or insertion cursor can be moved in 4 directions, left, right, top and bottom using the left, right, top and bottom arrow keys of the standard keyboard.
Left Right
Up
Down
Fig. 7-6:
Cursor movements
NOTE
After selecting a function block, if the user presses the Space key and an arrow key, it will move the Function block by 1 grid position respectively to the arrow key pressed.
The other key operations with the normal cursor or insertion cursor are as follows:
7 – 6
MITSUBISHI ELECTRIC
Guided Ladder Editor Main Features
Key
HOME
END
CTRL + HOME
CTRL + END
SHIFT+HOME
SHIFT+END
SHIFT + <Arrow key>
ENTER
CTRL + C or
CTRL + INSERT
CTRL + V or
SHIFT + INSERT
INSERT
CTRL+L
SPACE
SPACE + <Arrow key>
DELETE
CTRL+DOWN
CTRL+UP
Tab. 7-8:
Keyboard shortcuts
Operation
Move the cursor to the first element position of the row
Move the cursor to the last element position of the row, only if circuit wrapping is set
Move the cursor to the first element position of the first row
Move the cursor to the first element position of the last row
Select all grids from the current position to the first element position of the row.
Select all grids from the current position to the last element position of the row, only if circuit wrapping is set. This has no effect when circuit-wrapping position is not set.
Selects the consecutive program components from the current cursor location in the direction of cursor movement until the arrow key is released.
Displays the instruction and the device name/variable name in the Character
Mode Input dialogue.
Copies the program components in the cursor selected area
Pastes the copied program components at the current cursor location
Toggles between Overwrite Mode and Insert Mode
Activates Line Mode
Selects/deselects the function block, if the cursor is over FB.
Moves the function block by 1 grid position in arrow key direction.
Deletes the program component at the current cursor location, except function block or deletes the function block only if it is selected with SPACE key.
Adds a new row to the end of the current network
Deletes the last empty row of the current network
Selection of normal cursor or insertion cursor area
When some consecutive cursor areas are selected with SHIFT Key, the selected area will appear as shown below:
By default, solid fill with Blue color (RGB= 0,0,255),
Fig. 7-7:
Selected cursor area
The user can change the color of the cursor using the View - Colors - Cursor Fill menu. The
View - Colors - Cursor Fill will display a color selection dialogue same as the dialogue for changing the color of the Grid or Background in the previous version of GX IEC Developer.
GX IEC Developer Reference Manual 7 – 7
Main Features Guided Ladder Editor
Color Selection Dialogue
The Color selection dialogue same as the following will be displayed for all the cursor related color selection menu items. The user can change or set the color using this dialogue.
Fig. 7-8:
Color Selection Dialogue
Cursor and the program components
Contact:
Horizontal lines will be added left and right of the contact, to fit the size of the cursor.
Fig. 7-9:
Contact
NOTE
Coil:
Horizontal lines will be added only at the left of the coil, to fit the size of the cursor.
Current Size
Modified Size
Expanded to fit to the size of cursor
Fig. 7-10:
Coil
There is no horizontal line at the right of the coil to avoid compiler errors.
7 – 8
MITSUBISHI ELECTRIC
Guided Ladder Editor
Function block:
There is no change in the size of the function block.
Current Size
Modified Size
Main Features
No changes in size
Fig. 7-11:
Function block
Horizontal line:
A line with a width of a grid will be added at the right side of the horizontal line, to fit the size of the cursor.
Current Size
Modified Size
Expanded to fit to the size of cursor
Fig. 7-12:
Horizontal line
Vertical line:
A line of grid width will be added at the bottom of the vertical line, to fit the size of the cursor.
Current Size
Modified Size
Expanded to fit to the size of cursor
Fig. 7-13:
Vertical line
NOTES
The above mentioned changes in the size of the program components do not change the sizes of the program components of other modes.
The expansion of the size of program components should be made as the method of adding lines with the program components in Interconnect or moving the program components when Auto connect feature is enabled, so that there is no difference between the current sizes of the program components, internally.
GX IEC Developer Reference Manual 7 – 9
Main Features
7.1.3
Guided Ladder Editor
Guided editing
Guided Editing allows the user to edit a program using simple keyboard operations.
The main features of Guided Editing are:
쎲 Programming using keyboard
쎲 Automatic ladder circuit wrapping at the user defined location
쎲 Selection of program components with keyboard
쎲 Insertion and deletion of program components
쎲 Positioning of function blocks
Programming using keyboard
In Guided Mode, a ladder circuit can be created, simply by pressing the hotkeys of the program components in a sequence. The program component will be placed at the current cursor location and after placing the program component the cursor will be moved to the next position, horizontally. If the next position is exceeding the user defined wrapping location, the cursor will be shifted to the position where the next program component can be placed.
1 1 1
7
�
6
�
NOTE
1 1
Fig. 7-14:
Programming using keyboard
� Short cut key
� Current cursor position
The above circuit can be created in 3 steps as given below:
쎲 Step 1: Press the keys 1-1-1-7 and 1-1 in sequence.
쎲 Step 2: Move the cursor to the top of the vertical connecting line position.
쎲 Step 3: Press the key 6.
The above method is applicable when the user does not check the Do not allow “?” as a
variable name of Ladder Editing settings. If it is checked, the user has to set the variable name using the
V
ariable Selection dialogue.
7 – 10
MITSUBISHI ELECTRIC
Guided Ladder Editor Main Features
Automatic ladder circuit wrapping at the user defined location
The following operations will be carried out, if the ladder circuit wrapping is active.
쎲 Wrapping of circuit:
If the ladder circuit exceeds the user-defined location, it will be wrapped. Refer to Wrap after setting in the Ladder option window.
Fig. 7-15:
Wrapping of circuit
NOTES
The wrapping is adapted from the current Inter connect mode or moving the program components when auto connect feature be enabled.
The user-defined wrapping location is valid only for the program component that is going to be placed in the network and it will not have any effect on pre-created networks or already positioned program components.
In active wrapping mode it is possible to shift the elements beyond the wrapping position. In the following example, a new contact is inserted. The user will be prompted to disable the wrapping for this action.
Fig. 7-16:
A new contact is inserted in an already filled line
Fig. 7-17:
Displayed warning
GX IEC Developer Reference Manual 7 – 11
Main Features Guided Ladder Editor
If the ladder circuit wrapping is temporarily disabled, the contact will be inserted although it exceeds the user-defined location:
Fig. 7-18:
Insertion of a contact
쎲 Positioning of coil
If the ladder circuit does not exceed the user-defined location and it has a coil at the end, the coil will be positioned and placed according to the user-defined wrapping location.
7 – 12
Fig. 7-19:
Positioning of coil
Insertion and deletion of program components
A program component can be inserted or deleted after selecting it. Insertion and deletion of program components can be done as an Overwrite or as an Insertion according to the activation of the Insert key of the standard keyboard.
According to the activation of the Insert key, the menu item Insert Mode or Overwrite Mode of the Guided Mode menu will be checked or not checked.
� �
Fig. 7-20:
Guided Mode menu
No.
Explanation
No check mark on Insert Mode means that Overwrite Mode is selected (check mark on Overwrite Mode)
Insert Mode – Can be activated by Insert key.
Tab. 7-9:
Explanation for Fig. 7-20
MITSUBISHI ELECTRIC
Guided Ladder Editor
Insertion and deletion with no Insert key activation - Overwrite Mode
쎲 Insertion
The cursor is here and 1 key is pressed to insert new contact.
Main Features
The contact is overwritten.
The vertical line is not deleted.
Fig. 7-21:
Insertion
쎲 Deletion
The cursor is here and
Delete key is pressed to delete this contact.
The contact at this position is deleted.
Fig. 7-22:
Deletion
GX IEC Developer Reference Manual 7 – 13
Main Features
Insertion and deletion with Insert key activation - Insert Mode
쎲 Insertion
The cursor is here and 1 key is pressed to insert new contact.
Guided Ladder Editor
The contact is inserted and the cursor is moved along with the contact at the inserted position.
Fig. 7-23:
Insertion
쎲 Deletion
The cursor is here and
Delete key is pressed to delete this contact.
The contact and vertical line at this position are deleted and it replaced with a horizontal line.
Fig. 7-24:
Deletion
Deleting single selected elements
All elements inside the cursor rectangle (except FB) are selected automatically. Specific selection of single elements is possible by pressing the SPACE-key. With each SPACE, the selection changes to the next element which is completely or partially inside the grid.
SPACE
SPACE
Fig. 7-25:
Selection of a single element
7 – 14
MITSUBISHI ELECTRIC
Guided Ladder Editor Main Features
Deletion of connecting lines
Deletion of only connecting lines is also possible using the Delete Line menu item under the menu Tools - Network Elements.
Using Delete line, only these connecting lines can be deleted.
Fig. 7-26:
Deletion of connecting lines
After selecting the Delete Line menu item (not the delete key), if the cursor is moved over the network, the connecting lines will be deleted. Delete Line will not delete any program components.
Open Row and Open Column in Guided Mode
Open Row and Open Column menu items under the Tools menu can be used to add a new cursor row, cursor column respectively at the cursor position.
쎲 Open Row:
Fig. 7-27:
Open Row
If Open Row is executed at the above cursor position, the circuit will be changed as shown below.
Fig. 7-28:
Open Row
GX IEC Developer Reference Manual 7 – 15
Main Features
쎲 Open Column:
Guided Ladder Editor
Fig. 7-29:
Open Column
If Open column is executed at the above cursor position, the circuit will be changed as shown below.
Fig. 7-30:
Open Column
NOTES
During insertion and deletion with no Insert key activation, Normal cursor will be displayed.
(Ref. Cursor for Guided Mode)
During insertion and deletion with Insert key activation, Insertion cursor will be displayed.
(Ref. Cursor for Guided Mode)
The status of activation of the Insert key will be displayed on status bar. “OVR” will be displayed when Insert key is not pressed, “INS” will be displayed when Insert key is pressed and it will be empty for all other modes. User can add or delete the status panel of the OVR or
INS display from the status bar, using the View - Configure Status Bar menu.
Deleting of multiple program components is also possible, if they are selected with the cursor.
The insertion of program components at the last cursor position from the point of user defined wrapping location is not allowed. But the overwrite or the deletion of program component at the last cursor position from the point of user defined wrapping location is allowed.
Insertion & User-defined circuit wrapping :
In general, when a program component is inserted, the circuit will be expanded horizontally.
But, the circuit cannot be expanded or wrapped after the user-defined wrapping settings.
The insert key activation and deactivation is common to all ladder networks in the project.
7 – 16
MITSUBISHI ELECTRIC
Guided Ladder Editor
NOTES
Main Features
Wrapping is not possible when inserting a program component, if the circuit has some user-defined location and there is no more space to insert a new component. In that case, a dialogue will be displayed to choose if the wrapping should be temporarily disabled.
Open column is also not possible if the inserted column exceeds the circuit wrapping setting.
Refer to the Wrap after setting in the Ladder option window.
GX IEC Developer Reference Manual 7 – 17
Main Features Guided Ladder Editor
Positioning of function blocks
If the user tries to place a function block in the Guided Mode, the Function Block Selection dialogue will be displayed. The user has to select the function block from the operators list box and then press the Apply button to place a function block in the network.
Fig. 7-31:
Function Block Selection
7 – 18
Minimum cursor area needed for a function block
For placing a function block, a minimum cursor area is needed. It is calculated as follow:
�
�
�
Fig. 7-32:
Minimum cursor area needed for a function block
No.
�
�
�
Explanation
Current Cursor location
Required Width of FB (RWFB)
Required Height of FB (RHFB)
Tab. 7-10: Explanation for Fig. 7-32
MITSUBISHI ELECTRIC
Guided Ladder Editor Main Features
In general,
Required Height of Function Block = Actual Height of Funct ion Block
+ cursor area at the bottom of function Block
Required Width of Function Block = Actual Width of Function Block
+
1 cursor area on both left and right of the Function Block
More precise, it can be calculated as given below:
Calculating Required Height of FB (RHFB)
If (AHFB
Mod 5) not equal to 0
RHFB = (((AHFB
– (AHFB Mod 5)) /5)+ 2) * 5
NOTES
If (AHFB Mod 5) equal to 0
RHFB = ((AHFB /5)+ 1) * 5
Where,
AHFB = Actual Height of Function Block
RHFB = Required Height of Function Block
Calculating Required Width of FB (RWFB)
If (AWFB Mod 5) not equal to 0
RWFB = (((AWFB – (AWFB Mod 5)) /5)+ 3) * 5
If (AWFB Mod 5) equal to 0
RWFB = ((AWFB /5)+ 2) * 5
Where,
AWFB = Actual Width of Function Block
RWFB = Required Width of Function Block
If there is no minimum cursor area in the circuit, the function block cannot be placed in a network. An error message as shown below will be displayed if there is no minimum cursor area.
Consecutive placement of FB/FUN is possible, if the FB/FUN to be placed does not hide any element or exceeds the user defined network wrap settings.
GX IEC Developer Reference Manual 7 – 19
Main Features Guided Ladder Editor
Variable name of function block
The first 8 characters of the variable name of the function block will be displayed in the circuit.
While placing the function block, it will be positioned automatically to secure the space for a 8 characters length variable name. The variable name should be scrolled to view the characters after the 8 th position. The variable name will be displayed with “>”mark at the end (as shown below) if it exceeds 8 characters.
� �
�
�
�
�
�
Fig. 7-33:
Variable name of function block
No.
�
�
�
�
Explanation
Exceeding 8 characters
User has to create this part after placing FB
Space for 8 characters size variable name
A cursor row is deleted here to make FB in adjacent rows.
Tab. 7-11: Explanation for Fig. 7-33
NOTES
If there are no program components at the left or right side of a function block, the input variable or output variable will be added to the function block.
The input or output variable of a function block will be removed automatically, if the user places some connecting lines between the function block and other program component.
The horizontal connecting lines of circuit may get disconnected because of placing a function block in an existing circuit.
7 – 20
MITSUBISHI ELECTRIC
Guided Ladder Editor Main Features
Function block related operations
No.
1
2
3
4
Operation
Placement of FB
At the Top Left corner of a network
At the Top Right corner of a network
At the Bottom Left corner of a network
At the Bottom Right corner of a network
1
2
At the left end or the first cursor column of the network
1
1
Moving a function block
2
Inserting a function block or placing FB next to a contact
Deleting a function block
Implementation Details
1
1
2
1
1
1
2
It will be treated same as placing a function block by clicking at the Top Left grid of the network.
It will be treated same as placing a function block by clicking at the Top grid row of the network.
The current cursor location should be at 2 cursor locations prior to the Right end of the current cursor row.
It will be treated same as placing a function block by clicking at the Bottom Left grid of the network.
It will be treated same as placing a function block by clicking at the Bottom grid row of the network.
The current cursor location should be at 2 cursor locations prior to the Right end of the current cursor row.
It will be treated same as placing a function block by clicking at the Left most grid of the network.
The function block should be selected with Space Key.
After selecting the function block, it can be moved using arrow keys while Space key is pressed. Each pressing of the arrow key will move the function block by one grid position.
It will be treated same as placing a function block by clicking at the Left most grid of the network.
The function block should be selected with Space Key.
After selecting the function block, it can be deleted by pressing the Delete key.
Tab. 7-12: Function block related operations
Connecting Function block pins with some other program component
Connecting FB pins with the other part of a program component can be drawn using Grid cursor
Fig. 7-34:
Connecting Function block pins
Placing the input and output variables of a function block
In Line Mode, the user can place the input or output variable of a function block using menu items or the hotkeys. The input or output variables of a function block cannot be placed in
Insert and Overwrite modes.
GX IEC Developer Reference Manual 7 – 21
Main Features
Creating connected and unconnected crossing
Guided Ladder Editor
Fig. 7-35:
Start
To make an unconnected crossing after M2 and M11, the Vertical line key (Hotkey 5) should be pressed after selecting the cursor area of contact M3, cursor area next to contact M8 and the cursor area next to contact M11 using the Shift and Arrow keys or dragging the cursor using the mouse.
Unconnected crossing
Fig. 7-36:
Unconnected crossing
To make a connected crossing, the Vertical line key (Hotkey 5) should be pressed at two locations, at cursor area of contact M3 and cursor area next to contact M8.
Connected crossing
Fig. 7-37:
Connected crossing
7 – 22
MITSUBISHI ELECTRIC
Guided Ladder Editor
7.1.4
Main Features
Character mode
The Character Mode is a function implemented inside the Guided Mode. It can be accessed by typing the direct instructions for the placement of program components in the Guided Mode and it cannot be accessed directly from the menu.
The placement of program components in a network is possible by typing the direct instructions. The program component will be inserted at the current cursor position.
The following is the list of instructions that can be used to access Character Mode in Guided
Mode. (The items in bold letters in the following table are the instructions.)
No.
1
2
3
4
5
6
7
8
9
10
11
12
Instruction
LD Device/Variable name
DI Device/Variable name
OUT Device/Variable name
FB [Function block name]
HL Count
VL Count
LDL Device/Variable name
LDI L Device/Variable name
Program Component Remarks
Contact
Contact negation
Program component with valid device/variable name can be entered directly. In case of unknown variable name, the Variable Selection dialogue will be displayed.
Program component with valid device/variable name can be entered directly. In case of unknown variable name, the Variable Selection dialogue will be displayed.
Coil
Function Block
Horizontal Line
Vertical Line
L Connection Contact
L Connection Contact negation
Program component with valid device/variable name can be entered directly. In case of unknown variable name, the Variable Selection dialogue will be displayed.
If a valid ‘Function block name’ is entered, the function block will be placed. Otherwise, the
Function Block Selection dialogue will be displayed.
Draws horizontal lines according to the value set in Count.
Draws vertical lines according to the value set in
Count.
Program component with valid device/variable name can be entered directly. In case of unknown variable name, the Variable Selection dialogue will be displayed.
Program component with valid device/variable name can be entered directly. In case of unknown variable name, the Variable Selection dialogue will be displayed.
JMP
Label Jump
IV Device/Variable name
OV Device/Variable name
Input Variable
Output Variable
Program component with valid device/variable name can be entered directly. In case of unknown variable name, the Variable Selection dialogue will be displayed.
Program component with valid device/variable name can be entered directly. In case of unknown variable name, the Variable Selection dialogue will be displayed.
RET
Return
Tab. 7-13: Character mode
GX IEC Developer Reference Manual 7 – 23
Main Features Guided Ladder Editor
Character Mode input
In Guided Mode, if the user presses any of the alphabet keys or just the Enter key, the
Character Mode Input dialogue will be displayed.
�
�
�
Fig. 7-38:
Character Mode input
No.
�
�
�
�
�
Explanation
Combo box for selecting the instruction
Space for typing the instruction
Update the contents
Close the dialogue
Instruction help information
Tab. 7-14: Explanation for Fig. 7-38
� �
In the Character Mode the user can directly input instructions in any of the 2 methods:
쎲 Select the instruction from the combo box and type the device/variable name.
쎲 Type the instruction and device/variable name in the Edit box itself.
After inputting the direct instruction, the user has to press the Enter button or Enter key of the keyboard to update it to the network. To close the Character mode input dialogue, the Close button or ESC key of the keyboard should be pressed. Some help information to type the instruction will be displayed if the user presses the [?] button or F1 key of the keyboard.
The character mode input dialogue will be closed after every successful direct command input and it will appear again if the user presses any of the alphabet keys or just the Enter key.
If there is no instruction or ‘FB’ selected in the combo box and characters are typed into the edit field, a list opens automatically at the bottom of the edit field. This list selects the first function block, which matches the entered character combination. By pressing the cursor down key, the list can be entered as the proper function block and can be selected to the edit field by the
ENTER key.
7 – 24
Fig. 7-39:
Character mode input
MITSUBISHI ELECTRIC
Guided Ladder Editor Main Features
The function block name can be extended with all valid variable names, separated by SPACE.
These variables are automatically added to the function block. If there are more input/output pins left than variables and ‘Automatic Input/Output Variables’ is active, ‘?’ is selected as variable name. If the function block is placed next to a horizontal line, the corresponding input pin is connected to this line and an assigned variable is ignored.
As soon as a valid function is recognised by a following SPACE, a ToolTip window appears, showing the variable definition from the corresponding header. The current edited variable will be highlighted in the ToolTip window.
Fig. 7-40:
Function block name
Fig. 7-41:
Input of a variable
Fig. 7-42:
Inserted function block
GX IEC Developer Reference Manual 7 – 25
Main Features
NOTE
Guided Ladder Editor
If the variable name of the user typed instruction is not present in the Global, Local header settings, Variable Selection dialogue will be displayed automatically.
The user has to set the variable name using the Variable Selection dialogue before the program component is placed in the network.
Fig. 7-43:
Variable selection
NOTES
7.1.5
An error will be displayed if there is any error in the instruction, the device, the variable, or function block name typed in the Character Mode Input dialogue.
Variable selection dialogue will be displayed, if the user presses the F2 key after clicking the space for typing instructions of the Character Mode Input dialogue. The variable selected in the Variable Selection dialogue will appear in the Character Mode Input dialogue, if the user presses the Apply button of the Variable Selection dialogue.
If Enter key is pressed and there is some program component at the location of the Guided
mode cursor, the Character Mode Input dialogue will be opened and the direct instruction for the program component will be displayed. (IV & OV instructions are available only in Line
Mode.)
The user can overwrite or insert an element using Character Mode Input dialogue, but incase of FB it is possible only if there is a Minimum cursor area for a function block.
Auto comment
Auto Comment is an option available in Guided Mode. The purpose of Auto comment is to induce the user to insert a comment into the network that is created in Guided Mode.
The properties of Auto Comment are:
쎲 It will insert a comment block at the beginning of a new network created using Edit - New
Network menu item in Guided Mode.
쎲 It will also insert a comment block at the beginning of the network if the placement of the very first program component is made in Guided Mode
,
even if network is created newly in
Select Mode or Interconnect Mode.
쎲 Auto Comment option does not have any effect on the networks created by placing the very first program component in Select Mode or Interconnect Mode
.
The comment blocks will not be added for those networks.
쎲 The number of characters per Comment line depends on the Auto Comment block width value in the Ladder Option settings. The height of the comment block will be grown or expanded, if the number characters in a comment line exceed the Auto Comment block
width.
7 – 26
MITSUBISHI ELECTRIC
Guided Ladder Editor Main Features
�
�
�
Fig. 7-44:
Comment block
No.
�
�
�
Explanation
Comment block
Equal to the value set in the Comment block width settings
Grow with Comment
Tab. 7-15: Explanation for Fig. 7-44
쎲 Auto comment will be disabled if Esc key is pressed and no new auto comment blocks will be added for the new network created using Edit-New Network menu item or the placement of the very first program component is made in Guided Mode. It is effective only for the active project.
쎲 Auto Comment will be enabled when the user selects Guided Mode in a new project.
Second cursor row
Fig 7-45:
Second cursor row
쎲 When Auto Comment is enabled, the very first program component will be placed at the second Guided Mode cursor row from the top of the active network.
쎲 When the height of the Auto Comment block exceeds the height of the Guided Mode cursor, a new Guided Mode cursor row will be inserted at the bottom of the current comment block to make it grow further.
Fig. 7-46:
Height of the Auto Comment block
쎲 In Guided Mode, the user can edit an Auto Comment block by placing the Guided Mode cursor over it and pressing the Enter key.
GX IEC Developer Reference Manual 7 – 27
Main Features Guided Ladder Editor
Fig. 7-47:
Placing the Guided Mode cursor
쎲 The maximum number of characters in a comment block is that of Select Mode and there is no change in Guided Mode.
7 – 28
MITSUBISHI ELECTRIC
Guided Ladder Editor
7.1.6
Main Features
Characteristics of guided mode
Changing in & out of Guided Mode
Changing into Guided Mode or changing out of Guided Mode to some other mode can be done easily with the mouse click on toolbar buttons or using the menu or menu short cuts.
Toolbar Button:
�
�
Fig. 7-48:
Icons
�
No.
�
�
�
Explanation
Select mode
Interconnect Mode
Guided editing
Tab. 7-16: Explanation for Fig. 7-48
Menu:
Fig. 7-49:
Menu
Please refer to section 7.3 User-friendly hotkeys for the proper hotkeys of the above menu items.
Masked functions in Guided Mode
The functions available in other mode but not needed in Guided Mode will be masked and they cannot be used in Guided Mode.
The following functions will be masked in Guided Mode (in all Overwrite, Insert and Line
Mode):
쎲 [Tools]-[Auto Connect]
쎲 [Tools]-[Recalculate Line]
The following functions will be masked in Overwrite and Insert Mode but available in Line
Mode:
쎲 [Tools]-[Network Elements]-[Input Variable]
쎲 [Tools]-[Network Elements]-[Output Variable]
GX IEC Developer Reference Manual 7 – 29
Main Features Guided Ladder Editor
Functions specific to Guided Mode
The following menu items are specific to Guided Mode:
[Guided Mode]- [Insert Mode]
[Guided Mode]-[Line Mode]
[Guided Mode]-[Auto Comment]
[Tools]-[Network Elements]-[Delete Line]
Right Click Menu items
In Guided Mode, the user can access the following menu items using right click on the ladder editor window. The right click menu items are dependent of the current user selection Mode and will change accordingly.
Right click menu item
Select Mode
Interconnect Mode
Insert Mode
Line Mode
Auto Comment
———————————————-
Open Row
Open Column
Delete Line
Disable Circuit wrapping
Input Variable
Output Variable
Remarks
Changes to the Select Mode
Changes to the Interconnect Mode
Toggles Insert and Overwrite Mode
Changes to Line Mode
Toggles Auto Comment
A separator
Inserts a new cursor row at the current cursor location
Inserts a new cursor column at the current cursor location
Activate/deactivate the delete line function
Disables the circuit wrapping settings. (Displayed only when the user has made the circuit wrapping settings.)
Places an input variable of a function block.
(Displayed only in Line Mode.)
Places an output variable of a function block.
(Displayed only in Line Mode.)
Tab. 7-17: Right Click Menu items
NOTE
The menu item Guided Editing will be added with the current right click menu of the Select
Mode or Interconnect Mode. The user can activate the Guided Mode from Select or
Interconnect Mode, by clicking the Guided Editing right click menu item.
7 – 30
MITSUBISHI ELECTRIC
Guided Ladder Editor
7.1.7
Main Features
Editing a pre-created circuit in Guided Mode
The following circuit locations cannot be edited in Guided Mode. The Guided mode cursor can scroll over the location but does not have any effect on it.
A part of a multiline variable name
This portion can be scrolled but cannot edited
This portion can be scrolled and edited
Fig. 7-50:
Editing a pre-created circuit
The cursor can scroll over the variable name but the variable name can be edited only if the cursor is over a program component and not over a part of a variable name.
A part of a function block
Fig. 7-51:
Scrolled function block
NOTES
The following operations can be done at the part of a function block.
쎲 The function block can be deleted, if it is already selected.
쎲 Horizontal and vertical lines can be drawn using Grid cursor.
GX IEC Developer Reference Manual 7 – 31
Main Features
7.1.8
Guided Ladder Editor
Ladder option settings
Ladder Editing Option settings can be accessed using Extras - Options menu.
LD-Variable Name option
The options related to Ladder variable name can be changed using the LD-Variable Name option.
Fig. 7-52:
Options menu
No Multiline variable naming: No multilane variable naming.
Display the variable name in n Lines: Wrap or fold the variable name in n (n=1 to 4 lines
(maximum allowable variable length is 32 (4 x 8 characters)) lines in the network display.
Do not allow “?” as a variable name: Do not allow the user to give the “?” mark as variable name in Guided Mode. When this option is checked, the user must specify a proper variable name whenever a new program component is placed in the network.
7 – 32
MITSUBISHI ELECTRIC
Guided Ladder Editor Main Features
LD-Guided Mode Option
The options related to Ladder Guided Mode can be changed using LD-Guided Mode option.
Fig. 7-53:
Options menu
NOTE
Do not wrap: Do not wrap the ladder circuit. This setting is applicable for the circuit that is going to be edited after making this setting and not for the pre-created circuits.
Wrap after: Wrap if the ladder circuit exceeds the n th
(n=2 to 100) component position. This setting is applicable for the circuit that is going to be edited after making this setting and not for the pre-created circuits.
Auto comment block width: Set the auto comment block with a width of n (n=1 to 100) components in the network.
Set Guided Mode as a default-editing mode: The project should be always opened in
Guided Mode.
Allow Hotkey repeater: Hotkey repeater window will be displayed whenever the Horizontal or
Vertical Line hotkey is pressed or accessed through the menu.
The above mentioned setting information will be stored in the .ini file.
GX IEC Developer Reference Manual 7 – 33
Enhanced functionalities
7.2
7.2.1
Enhanced functionalities
Guided Ladder Editor
Additional functionalities
The following are the additional functionalities:
Contact Negation
To place a negated Contact, so far the user had to change the Signal Configuration of the contact after placing it in the network. This additional functionality allows the direct placement of a negated Contact in the network.
Contact Negation
Fig. 7-54:
Contact Negation
7 – 34
L-Connection Contact
To place a L-Connection Contact, so far the user had to draw the connections after placing the contact in the network. This additional functionality allows the direct placement of a
L-Connection Contact in the network. In case of Guided Mode, the size of the vertical line depends on the variable name wrapping settings.
�
�
Fig. 7-55:
L-Connection Contact
No.
�
�
Explanation
This height will change with the multiline var. settings
L-Connection Contact
Tab. 7-18: Explanation for Fig. 7-55
L-Connection Contact Negation
Similar to L-Connection Contact, this functionality is used to place a direct L-Connection
Contact Negation in the network. In case of Guided Mode, the size of the vertical line depends on the variable name wrapping settings.
�
�
Fig. 7-56:
L-Connection Contact Negation
No.
�
�
Explanation
This height will change with the multiline var. settings
L-Connection Contact
Tab. 7-19: Explanation for Fig. 7-56
MITSUBISHI ELECTRIC
Guided Ladder Editor
7.2.2
Enhanced functionalities
Modified functionalities
The following functionalities that had been available in GX IEC Developer before version 7.00
were modified as shown below.
Hotkey repeater for Horizontal line
When the user pressed the hotkey or menu item of a horizontal line, a horizontal line was placed at the mouse click location. Since version 7.00 the following dialogue is displayed before placing the horizontal line in a network.
� � � �
Fig. 7-57:
Hotkey repeater for Horizontal line
No.
�
�
�
�
Explanation
Count for Horizontal line
Enter Horizontal line
Close or cancel the dialogue
Display some help information
Tab. 7-20: Explanation for Fig. 7-57
By default the count for Horizontal line is 1. But the user can draw more than 1 horizontal line from a cursor location, just by increasing the count value.
Hotkey repeater for Vertical line
When the user pressed the hotkey or menu item of a vertical line, a vertical line was placed at the mouse click location. Since version 7.00 the following dialogue is displayed before placing the vertical line in a network.
� � � �
Fig. 7-58:
Hotkey repeater for Vertical line
No.
�
�
�
�
Explanation
Count for Vertical line
Enter Vertical line
Close or cancel the dialogue
Display some help information
Tab. 7-21: Explanation for Fig. 7-58
By default the count for Vertical line is 1. But the user can draw more than 1 vertical line from a cursor location, just by increasing the count value.
GX IEC Developer Reference Manual 7 – 35
User-friendly hotkeys
7.3
Guided Ladder Editor
User-friendly hotkeys
The following are the user-friendly hotkeys of GX IEC Developer.
� � �
Guided Editing
� 쐅
� � � � �
Fig. 7-59:
Hotkey icons
No.
�
�
�
�
�
�
�
�
�
쐅
Symbol
Contact (Hot Key = 1)
Contact Negation (Hot Key = 2)
L-Connection Contact (Hot Key = 3)
L-Connection Contact Negation (Hot Key = 4)
Vertical line (Hot Key = 5)
Horizontal line (Hot Key = 6)
Coil (Hot Key = 7)
Function Block (Hot Key = 8)
Input Variable (Hot Key = 9)
Output Variable (Hot Key = 0)
Tab. 7-22: Explanation for Fig. 7-59
The location of the following toolbar buttons for program components is shown in Fig. 7-59.
�
�
Fig. 7-60:
Icons
�
The above hotkeys for program components are revised or allocated according to the MEDOC standards.
No.
�
�
�
Description
Auto comment
Label of the network
Delete Line
Tab. 7-23: Explanation for Fig. 7-60
The Label/Title dialogue is displayed if the user presses the Label of the network button.
7 – 36
MITSUBISHI ELECTRIC
Guided Ladder Editor
Menu and the Hotkeys
Tools - Network Elements
Fig. 7-61:
Menu
User-friendly hotkeys
Tools - Guided Mode
Fig. 7-62:
Menu
GX IEC Developer Reference Manual 7 – 37
User-friendly hotkeys Guided Ladder Editor
Toolbar buttons and Mouse cursors
The following mouse cursors are displayed when the toolbar buttons or the menu items are accessed. But there is no mouse cursor displayed for the functions related to Guided Mode and for functions that do not need a specialized mouse cursor for their operations (e.g. Label of a network).
No.
Function Name Mouse cursor Remarks
1 Contact Negation
2 L-Connection Contact
3 L-Connection Contact Negation
4
5
6
7
8
9
Horizontal Line Segment
Vertical Line Segment
Guided Editing
Label of a network
Auto Comment
Delete Line
Same as GID Ver. 5
Same as GID Ver. 5
No mouse cursor needed
No mouse cursor needed
No mouse cursor needed
No mouse cursor needed
Tab. 7-24: Toolbar buttons and Mouse cursors
Only the tool button is added
Only the tool button is added
7 – 38
MITSUBISHI ELECTRIC
Guided Ladder Editor
7.3.1
User-friendly hotkeys
Enhanced program component variable name display
For a proper display the variable name of the program components in a network had to be adjusted manually. Now the variable names will be arranged automatically before they are displayed.
Multiline variable naming
The variable name displayed above a program component can be wrapped/folded according to the Display variable name in ** lines setting of the Ladder Editing settings.
A lengthy variable name,
Example:
[ABCDEFGHabcdefgh12345678XYZ] will be displayed like this, if it is made to be displayed in 3 lines
Fig. 7-63:
Multiline variable naming
The rules for variable name wrapping are:
쎲 Each line in the variable name can accept a maximum of 8 characters
쎲 The remaining part of the variable name that does not appear in the display can be viewed by scrolling the variable name. (In the above example the last 3 characters
[XYZ] of [ABCDEFGHabcdefgh12345678XYZ] can be viewed by scrolling it.)
Multiline variable naming and the Behaviour of Guided Mode cursor
Cursor row
Fig. 7-64:
Cursor row
NOTE
The cursor can scroll over the variable name but the variable name can be edited only if the cursor is over a program component and not over a part of a variable name. But the user can edit the part of a multiline variable name in Select or Inter connect mode.
If multiline variable name is allowed/selected and the variable name has more than 8 characters, a new cursor row will be added above the current cursor.
GX IEC Developer Reference Manual 7 – 39
User-friendly hotkeys Guided Ladder Editor
Alignment of variable name in Guided Mode
All variable name displays are centre aligned in each line and the variable name is bottom aligned in the variable name box. If the variable name is 27 characters long and the „Display variable name in n lines“ is set to 8, the variable name will be displayed as shown below.
Space for 4 lines of variable name and no program component is allowed to place over this row.
Fig. 7-65:
Alignment of variable name
NOTES
Regardless of the mode of ladder editing, the variable name display is centre aligned in each line and the variable name is bottom aligned in the variable name box.
The width of the variable name display changes with the type of the font set for the Body. So to implement the enhanced display of the variable name, the font for the Body must be set with a fixed size font like Courier new font always.
Example
The width of the variable name changes with the font.
Courier new font
Arial font
Width of the variable name display is same for all cases
Fig. 7-66:
Example
Width of the variable name display is not same for all cases
쑶
About scrolling a multiline variable name:
No scrollbars appear inside the Edit control. The user can scroll down until reaching the end of the variable name. Behind the end of scrolling region the cursor inside the edit box will not move down any further. Since the default settings for the variable name wrapping is 3 lines (3 x 8 characters), even if the user sets a variable name of 32 characters length, scrolling down only two lines is possible.
7 – 40
MITSUBISHI ELECTRIC
Guided Ladder Editor
7.3.2
User-friendly hotkeys
Ladder circuit printout
In general, there are no changes in the printing settings of the current GX IEC Developer.
Regarding the printing of a ladder circuit, the following point should be taken care of:
Since the Courier New font is used for creating the ladder circuit in Guided Mode, there is a necessity to maintain the same font in printing also. In Guided Mode, if the user changes the default font settings from Courier New font to some other font, the variable names in the ladder circuit may get overlapped on both the computer screen as well as in the printout.
GX IEC Developer Reference Manual 7 – 41
User-friendly hotkeys Guided Ladder Editor
7 – 42
MITSUBISHI ELECTRIC
Compiling and Downloading Programs
8 Compiling and Downloading
Programs
Error Check
8.1
NOTE
Error Check
Before compiling your project it is advisable to perform an error check on the project or individual objects. The following checks are carried out:
Header
Checks of all the variable declarations (unique descriptors, addressing etc).
Body
The following checks are performed in the editors:
Graphical editors
쎲 Validity of the data types
쎲 Variable names (declarations)
쎲 Validity of the IEC addresses
쎲 Validity of the MITSUBISHI addresses
쎲 Definition of the input variables
쎲 Recursions
쎲 Interconnects
쎲 Label syntax
Text editors
쎲 Syntax of the operators and operands
쎲 Number of operands
쎲 Recursions
쎲 Jumps
쎲 Comments
Errors and warnings are displayed in the Compiler/Check Messages status window with explanations.
When you double-click on an error message or warning in the status window GX IEC
Developer automatically opens the corresponding object, moves the point in the program where the error was found and highlights the error in a different colour. The jumped to position in for example an editor of IL, MELSEC IL or ST may not be the exact position of the error cause. Look for the error cause in the jumped to line or in the lines above.
GX IEC Developer Reference Manual 8 – 1
Error Check Compiling and Downloading Programs
NOTE
How to perform an error check on an object
햲 Select Check in the Object menu.
Or:
Click with the left mouse button on the Check tool:
You do not have to save your editing changes in open objects before selecting the Check option. If changes have been made the object is saved automatically before Check is executed.
How to specify the max. number of errors and warnings
햲 Select the option Stop Check By in the Extras - Options - General menu.
햳 Enter the maximum number of errors and warnings. The check operation will be stopped when the number of errors and warnings exceeds the limit specified here.
Range: 0 - 2,000.
8.1.1
Execution order
In some cases the execution order in a ladder or FBD network is not clear, for example if complex connections between different elements are established.
The scanner for ladder / FBD networks recognises these critical networks. In this case a warning is indicated in the dialogue Compile / Check Messages.
On demand the generated MELSEC IL code of the respective network will be displayed if the
POU has been compiled. To do so take the following steps:
햲 Select one or multiple networks.
햳 Select the menu item Tools → Show MELSEC Code Of Network.
8 – 2
MITSUBISHI ELECTRIC
Compiling and Downloading Programs
8.2
Compiling
Compiling
The compilation process translates the project written in GX IEC Developer into code that the
PLC CPU can execute. This translation process must be performed before downloading the program to the PLC system.
How to compile the complete project
Select Rebuild All in the Project menu.
GX IEC Developer first performs checks on all the objects in the project and displays any errors or warnings in the Compiler/Check Messages status window. If no errors are displayed this means that the program code has been compiled without errors.
Fig. 8-1:
Compiler/Check Messages
Once the project has been compiled, the Compiler/Check Messages status window can be opened any time via the menu item Window - Show Compile/Check Messages.
In the status window occurred errors and warnings can be browsed via the following Window menu items:
쎲 Show Next Error
Hotkey: [F4]
쎲 Show Previous Error Hotkey: [SHIFT] + [F4]
쎲 Show Next Warning
쎲 Show Previous Warning
GX IEC Developer Reference Manual 8 – 3
Compiling Compiling and Downloading Programs
NOTE
How to compile only modified objects
POUs that have not yet been compiled are identified in the Project Navigator with an asterisk.
POUs marked in this way were either created after the last compilation or are not part of a task.
Fig. 8-2:
Already compiled
Not yet compiled
햲 Select Build in the Project menu.
Only the new objects which have not yet been compiled and the project elements which depend on the changes will be compiled.
When you double-click on an error message or warning in the status window GX IEC
Developer automatically opens the corresponding object, moves the point in the program where the error was found and highlights the error in a different colour.
E
WARNING:
Please note that only those Program POUs that you have included in your tasks are checked and compiled!
Projects generated with program versions of MM+
You must completely recompile projects generated with program versions of MM+ (Compile
Project) before you can use the Build function on them to compile only changes made in the editing session.
8 – 4
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Downloading Projects to the CPU
8.3
8.3.1
NOTE
Downloading Projects to the CPU
Transfer Setup - Ports
You can only download compiled projects to the CPU. Before making your first download, check that the port and its parameters are configured correctly.
See chapter 2 and the manuals of your MELSEC hardware for details on connecting the
controller to your computer.
How to configure the communications port
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
The Transfer Setup menu has moved to the top of the Online menu.
Fig. 8-3:
Transfer Setup
GX IEC Developer Reference Manual 8 – 5
Downloading Projects to the CPU Compiling and Downloading Programs
A dialogue box will be opened with the following options:
쐃
�
�
�
�
쐈
쐉
씈
씉
�
쐅
�
쐊
�
Fig. 8-4:
Transfer Setup (1)
쐅
8 – 6
Fig. 8-4:
Transfer Setup for QnPRH CPU (2)
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Downloading Projects to the CPU
Fig. 8-4:
Transfer Setup for FX3U CPU (3)
쐉
쐇
Fig. 8-4:
Transfer Setup for Q Remote I/O (4)
GX IEC Developer Reference Manual 8 – 7
Downloading Projects to the CPU Compiling and Downloading Programs
Number Description
�
�
PC side I/F
Choose the I/F for the connection of the PC to the PLC.
PLC side I/F
Choose the unit to be connected with the personal computer.
�
�
Other station
Choose no network or one of the specified network types.
Network route
Choose the network type, network No., station number and first I/O No. to be accessed. The setting items depend on the network type that has been set.
�
�
�
�
�
Coexistence network route
Choose this when making access to the network different from the one where the personal computer is connected. Choose the network type, network No., station number and first I/O No. to be accessed.
The setting items depend on the network type that has been set.
Multiple PLC setting
Specify when the access target is multiple CPUs. You can connect up to four PLC CPUs. In this option you decide which CPU is to be connected.
Connection channel list…
Lists possible connection modes and their image. You can set the connection target while looking at the Connection channel list.
PLC direct coupled setting
By clicking this button you change from Other station to the own station.
Connection test
Tests whether proper access can be made to the PLC set as the access target on the Connection
Setup screen. If proper access can be made, the model name of the PLC as the access target appears in the CPU type field.
Target System
Specifies the connection destination for redundant PLC systems.
Choice
쐅
Not specified
Connection destination
When a PLC is directly connected:
The PLC directly connected to the personal computer.
Via network:
The PLC at the station where the network module of the specified station No.
is installed in the network communication path.
Control system
Standby system
System A
System B
The PLC whose system type is the control system.
The PLC whose system type is the standby system.
The PLC connected to the A side connector of the tracking cable.
The PLC connected to the B side connector of the tracking cable.
쐈
쐉
씈
씉
System image
Here you see an image of the setup system.
Line connected (Q/A6TEL, C24)... / TEL (FXCPU)...
Clicking on this button opens a dialogue to setup a modem connection.
OK
Closes the dialogue and saves the settings.
Cancel
Closes the dialogue without saving.
Tab. 8-1:
Description for Fig. 8-4
햲
For a redundant PLC system some functionalities are not available with all of these settings.
For the following functionalities it is necessary to select Not specified, System A or Sys-
tem B to function properly:
앫 In Cycle Monitoring (씮 9.13)
앫 Online Module Change (씮 9.8)
앫 Forced Input Output Registration / Cancellation (씮 9.11.1)
8 – 8
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Downloading Projects to the CPU
Setup of the connection to the PLC
To setup the connection follow the different setup option in Fig. 8-5. Therefore use the manuals
of the PLC CPU and the network type you are using.
GX IEC Developer provides the possibility to setup the PLC and network parameter by using graphical images.
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
The in Fig. 8-5 shown dialogue is opened.
햳 Click on the button Connection channel list. The following dialogue window is opened.
쐃
쐇
쐋 쐏
Fig. 8-5:
Dialogue Connection channel list
쐄
쐃 Graphical image of the in � selected network type.
쐇 Listing of the possible network configurations for the selected PLC .
쐋 Update
Click this button to confirm the selected network configuration without closing the dialogue.
쐏 OK
Confirm the set network configuration and close the dialogue.
쐄 Cancel
Closes the dialogue without saving. When the button Update was clicked the dialogue is closed but the network configuration is already saved.
GX IEC Developer Reference Manual 8 – 9
Downloading Projects to the CPU Compiling and Downloading Programs
햴 Use the scollingbar to scroll through the network configurations and select a network configuration corresponding to your network type by clicking in the list. Click on the button Update. Confirm the following security note with OK.
Fig. 8-6:
Security note
햵 Test the selected network configuration by clicking on the button Connection test. If the connection between the PC and the network is possible a positive note will be shown on the screen. If no connection is possible an error message is shown. In this case you have to check and correct the connection between the PC and the network.
햶 Close the dialogue by clicking on OK. The selected network configuration will be saved and shown in the Transfer Setup.
8 – 10
Fig. 8-7:
Dialogue Transfer Setup
햷 Now click on System image. An information window is opened in which an image of the setup system is shown.
In comparison to the Connection channel list dialogue in this dialogue the system parameter are also listed.
So you can change single settings and check the settings by the help of this dialogue.
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Downloading Projects to the CPU
Fig. 8-8:
Dialogue System image
NOTES
Example
The COM and USB status is saved to the INI file every time you close the Transfer Setup dialogue with the OK button. The saved values are then used as defaults when you create a new project.
The USB status is only saved for Q PLCs. The selected COM port is only saved if USB is not selected. For new projects, the USB status is used as default for Q PLCs, except the
Q00(J)/01 PLCs.
The following table shows the old Transfer Setup settings (Version 5.0 and before) and their equivalents in the new Transfer Setup (Version 6.0 and later).
Example for reading the table: If you selected the CPU-Port interface with MELSECNET/10 network in the old Transfer Setup, you will have to do the following in the new Transfer Setup to achieve the same result:
햲 Select the Serial / USB icon in the PC side I/F group.
햳 Double-click this icon to configure the settings such as port, baud rate, etc.
햴 Select the PLC module icon in the PLC side I/F group.
햵 Double-click this icon to configure the PLC mode (if the PLC supports this).
햶 Select the Other station (Single network) icon in the Other Station group.
햷 Double-click this icon to configure timeout and retries settings.
햸 Select the NET/10(H) icon from the Network Route group.
햹 Double-click this icon to configure the Network and Station numbers.
GX IEC Developer Reference Manual 8 – 11
Downloading Projects to the CPU
Old setting
CPU-Port
Host
CPU-Port
Net/NetII
CPU-Port
Net10
CPU-Port
CC-Link
Computer Link
Host
Computer Link
Net/NetII
Computer Link
Net10
Computer Link
CC-Link
Ethernet
Host
Ethernet
Net/NetII
Ethernet
Net10
Ethernet
CC-Link
USB Port
Host
USB Port
Net10
USB Port
CC-Link
New setting
Click to select…
PC side: Serial / USB
PLC side: PLC module
Other stat: No spec
PC side: Serial / USB
PLC side: PLC module
Other stat: Single network
Network: NET(II)
PC side: Serial / USB
PLC side: PLC module
Other stat: Single network
Network: NET/10(H)
PC side: Serial / USB
PLC side: PLC module
Other stat: Single network
Network: CC-Link
PC side: Serial / USB
PLC side: C24
Other stat: No spec
PC side: Serial / USB
PLC side: C24
Other stat: Single network
Network: NET(II)
PC side: Serial / USB
PLC side: C24
Other stat: Single network
Network: NET/10(H)
PC side: Serial / USB
PLC side: C24
Other stat: Single network
Network: CC-Link
PC side: Ethernet board
PLC side: Ethernet module
Other stat: Single network
Network: Ethernet
PC side: Ethernet board
PLC side: Ethernet module
Other stat: Co-existence
Network: Ethernet
Co-existence: NET(II)
PC side: Ethernet board
PLC side: Ethernet module
Other stat: Single network
Network: Ethernet
PC side: Ethernet board
PLC side: Ethernet module
Other stat: Co-existence
Network: Ethernet
Co-existence: CC-Link
PC side: Serial / USB
PLC side: PLC module
Other stat: No spec
PC side: Serial / USB
PLC side: PLC module
Other stat: Single network
Network: NET/10(H)
PC side: Serial / USB
PLC side: PLC module
Other stat: Single network
Network: CC-Link
Tab. 8-2:
Comparison of old and new setting
Compiling and Downloading Programs
Double-click to configure…
COM port, Baud rate
PLC mode
Timeout, retries
COM port, Baud rate
PLC mode
Timeout, retries
Station no.
COM port, Baud rate
PLC mode
Timeout, retries
Network no., station no.
COM port, Baud rate
PLC mode
Timeout, retries
Head I/O, station no.
COM port, Baud rate
PLC type, Station no., parity
Timeout, retries
COM port, Baud rate
PLC type, Station no., parity
Timeout, retries
Station no.
COM port, Baud rate
PLC type, Station no., parity
Timeout, retries
Network no., station no.
COM port, Baud rate
PLC type, Station no., parity
Timeout, retries
Head I/O, station no.
Network no., station no., protocol
PLC type, IP address, host name
Timeout, retries
Network no., station no.
Network no., station no., protocol
PLC type, IP address, host name
Timeout, retries
—
Station no.
Network no., station no., protocol
PLC type, IP address, host name
Timeout, retries
Network no., station no.
Network no., station no., protocol
PLC type, IP address, host name
Timeout, retries
Network no., station no.
Head I/O, station no.
Select USB
PLC mode
Timeout, retries
Select USB
PLC mode
Timeout, retries
Network no., station no.
Select USB
PLC mode
Timeout, retries
Head I/O, station no.
8 – 12
MITSUBISHI ELECTRIC
Compiling and Downloading Programs
8.4
Modem settings for analog Modems
Modem settings for analog Modems
When using an analog modem make the following settings.
햲 Set MAC transparent mode with CPU port or C24 in the menu Transfer Setup ->
Ports.
햳 Set the desired data transmission settings on the sending and receiving modems. You can use any terminal program (e.g. Windows Hyperterminal) to configure the modem settings.
햴 Click on the button Line connected in the menu Transfer Setup -> Ports.
Fig. 8-9:
Modem settings
GX IEC Developer Reference Manual 8 – 13
Modem settings for analog Modems Compiling and Downloading Programs
Connection: Enter the telephone number here. Or select one out of the Call book by clicking on the Browse button.
Fig. 8-10:
Call book
AT command: The modem settings are set here. Or select one out of the AT command regis-
tration by clicking on the Browse button.
8 – 14
Fig. 8-11:
AT command registration
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for analog Modems
Data transmission procedure
햲 Set data transmission settings in GX IEC Developer and on MAC.
햳 Receiving modem: set “Auto Answer On”.
햴 Set data transmission settings on receiving and sending modems.
햵 Start connection: dial receiving modem.
햶 Quit terminal software, though without hanging up.
햷 Take the necessary steps in GX IEC Developer.
NOTES
Close communications
When the PLC and other devices (e.g. the MAC terminal in transparent mode) are connected to the Personal Computer via the same communication port, the communications must be closed to release the COM port when switching between the two software applications GX IEC
Developer and MAC Programmer.
햲 Click on the command Close communications in the Online menu.
The communications can not be closed when GX IEC Developer is running in monitor mode.
Follow the following precautions for access to the other station in the following Q, QnA, and A
CPU mixed system are as follows:
Request source
Relay station
Request target
NET/10 NET/10
A CPU selected
Q/QnA
CPU
Fig. 8-12:
Hardware configuration for Q, QnA, and A CPU mixed systems.
AnA
CPU
햲 Change the peripheral device to the PLC type of the request target. Communication can not be performed, if the PLC type differs.
햳 The relay station used should be the Q CPU or QnA CPU.
햴 If GX IEC Developer is connected to the QnA CPU and the request target is the A CPU
GX IEC Developer can not communicate with the request target (A CPU).
햵 If GX IEC Developer is connected to the Q CPU and the request target is the Q CPU,
GX IEC Developer can not communicate with the request target (Q CPU) via the relay station (QnA/A CPU).
GX IEC Developer Reference Manual 8 – 15
Modem settings for GSM Modems
8.5
8.5.1
Compiling and Downloading Programs
Modem settings for GSM Modems
FX-Series – Communication via Programming port
Environment: Analogue Modem -> GSM Modem -> Programming port
Standard
RS232 cable (1:1)
Fig. 8-13:
Environment
MIM-A01
MIM-G01
PLC
FX-Series
Programming cable (SC09) with “Blue Adapter”
Analogue Modem settings:
AT E0
&S0
&D0
&K0
When the analogue modem is used at the PC side, the parity settings have to be modified:
Parity: Even
Data Bits: 7bits
Stop Bits: 1bit
AT +TFORMAT=”7E1”
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
+CPIN=____ (PIN No. of SIM card)
8 – 16
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-14:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-15:
Setting the communication details
GX IEC Developer Reference Manual 8 – 17
Modem settings for GSM Modems Compiling and Downloading Programs
햶 Select TEL (FXCPU), enter the Call number of the remote modem and click Connect.
8 – 18
Fig. 8-16:
Set up the connection
햷 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
← Call number of your remote modem
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
Environment: GSM Modem -> GSM Modem -> Programming port
Standard
RS232 cable (1:1)
Fig. 8-17:
Environment
MIM-G01 MIM-G01
PLC
FX-Series
Programming cable (SC09) with “Blue Adapter”
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
&W
+CPIN=____ (PIN No. of SIM card)
The modem which is used at the PC side has to be modified regarding the parity settings:
Parity: Even
Data Bits: 7bits
Stop Bits: 1bit
AT +ICF=5,1
GX IEC Developer Reference Manual 8 – 19
Modem settings for GSM Modems Compiling and Downloading Programs
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-18:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
8 – 20
Fig. 8-19:
Setting the communication details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
햶 Select TEL (FXCPU), enter the Call number of the remote modem and click Connect.
Fig. 8-20:
Set up the connection
햷 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
GX IEC Developer Reference Manual 8 – 21
Modem settings for GSM Modems Compiling and Downloading Programs
8.5.2
NOTE
FX-Series
– Communication with RS 232 BD
Environment: Analogue Modem -> GSM Modem -> RS 232 BD
A modification of the PLC settings for the RS 232 BD is not necessary.
Standard
RS232 cable (1:1)
Fig. 8-21:
Environment
MIM-A01 MIM-G01
Standard RS232 cable (1:1) with “Red Adapter”
PLC
FX-Series
Analogue Modem settings:
AT E0
&S0
&D0
&K0
When the analogue modem is used at the PC side, the parity settings have to be modified:
Parity: Even
Data Bits: 7bits
Stop Bits: 1bit
AT +TFORMAT=”7E1”
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
+CPIN=____ (PIN No. of SIM card)
8 – 22
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-22:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-23:
Setting the communication details
GX IEC Developer Reference Manual 8 – 23
Modem settings for GSM Modems Compiling and Downloading Programs
햶 Select TEL (FXCPU), enter the Call number of the remote modem and click Connect.
�
Fig. 8-24:
Set up the connection
햷 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
8 – 24
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
NOTE
Environment: GSM Modem -> GSM Modem -> RS 232 BD
A modification of the PLC settings for the RS 232 BD is not necessary.
Standard
RS232 cable (1:1)
Fig. 8-25:
Environment
MIM-G01 MIM-G01
Standard RS232 cable (1:1) with “Red Adapter”
PLC
FX-Series
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
+CPIN=____ (PIN No. of SIM card)
The modem which is used at the PC side has to be modified regarding the parity settings:
Parity: Even
Data Bits: 7bits
Stop Bits: 1bit
AT +ICF=5,1
GX IEC Developer Reference Manual 8 – 25
Modem settings for GSM Modems Compiling and Downloading Programs
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-26:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
8 – 26
Fig. 8-27:
Setting the communication details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
햶 Select TEL (FXCPU), enter the Call number of the remote modem and click Connect.
Fig. 8-28:
Set up the connection
햷 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
GX IEC Developer Reference Manual 8 – 27
Modem settings for GSM Modems
8.5.3
Compiling and Downloading Programs
FX-Series – Communication via MAC (Transparent Mode)
Settings for MAC Terminal:
8 – 28
Fig. 8-29:
Setting the peripheral configuration in the E-Designer
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
Environment: Analogue Modem -> GSM Modem -> MAC -> FX Programming Port
Standard
RS232 cable (1:1)
MIM-A01 MIM-G01
Crossed cable
1 --- 1
2 --- 3
3 --- 2
4 --- 6
5 --- 5
6 --- 4
7 --- 8
8 --- 7
MAC
Standard MAC cable
PLC
FX-Series
Fig. 8-30:
Environment
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
+CPIN=____ (PIN No. of SIM card)
Analogue Modem settings:
AT E0
&S0
&D0
&K0
When the analogue modem is used at the PC side, the parity settings have to be modified:
Parity: Even
Data Bits: 7bits
Stop Bits: 1bit
AT +TFORMAT=”7E1”
GX IEC Developer Reference Manual 8 – 29
Modem settings for GSM Modems Compiling and Downloading Programs
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-31:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
8 – 30
Fig. 8-32:
Setting the communication details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
햶 Double click on PLC side I/F - PLC Modul to open the dialogue box PLC side I/F
Detailed setting of PLC module and set the communication mode.
Fig. 8-33:
Setting the communication mode
햷 Select TEL (FXCPU), enter the Call number of the remote modem and click Connect.
Fig. 8-34:
Set up the connection
햸 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
GX IEC Developer Reference Manual 8 – 31
Modem settings for GSM Modems Compiling and Downloading Programs
Environment: GSM Modem -> GSM Modem -> MAC -> FX Progr. Port
Standard
RS232 cable (1:1)
MIM-G01 MIM-G01
Crossed cable
1 --- 1
2 --- 3
3 --- 2
4 --- 6
5 --- 5
6 --- 4
7 --- 8
8 --- 7
MAC
Standard MAC cable
PLC
FX-Series
Fig. 8-35:
Environment
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
&W
+CPIN=____ (PIN No. of SIM card)
The modem which is used at the PC side has to be modified regarding the parity settings:
Parity: Even
Data Bits: 7bits
Stop Bits: 1bit
AT +ICF=5,1
8 – 32
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-36:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-37:
Setting the communication details
GX IEC Developer Reference Manual 8 – 33
Modem settings for GSM Modems Compiling and Downloading Programs
햶 Double click on PLC side I/F - PLC Modul to open the dialogue box PLC side I/F
Detailed setting of PLC module and set the communication mode.
Fig. 8-38:
Setting the communication mode
햷 Select TEL (FXCPU), enter the Call number of the remote modem and click Connect.
8 – 34
Fig. 8-39:
Set up the connection
햸 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
Environment: GSM Modem -> GSM Alarm Modem -> FX Progr. Port
MIM-G01
Standard
RS232 cable (1:1)
Fig. 8-40:
Test environment
MAM-GM6
Standard RS232 cable (1:1) with “Red Adapter”
PLC
FX-Series
MIM-G01 settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
%C0
\N0
&W
+CPIN=____ (PIN No. of SIM card)
MAM-GM6 settings:
For the MAM-GM6 settings refer to MX Mitsubishi Alarm Editor
GX IEC Developer Reference Manual 8 – 35
Modem settings for GSM Modems Compiling and Downloading Programs
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-41:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
8 – 36
Fig. 8-42:
Setting the communication details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
햶 To connect the modems you have to use the MX Mitsubishi Alarm Editor.
The following screenshot shows the settings.
Fig. 8-43:
Settings in the MX Mitsubishi Alarm Editor
햷 To connect the modems click on the button Connect.
GX IEC Developer Reference Manual 8 – 37
Modem settings for GSM Modems Compiling and Downloading Programs
햸 After the connection has been established the following message is displayed.
Fig. 8-44:
Connection message
8 – 38
MITSUBISHI ELECTRIC
Modem settings for GSM Modems Compiling and Downloading Programs
8.5.4
A-Series – Communication with C24
Settings for AJ71C24
Mode switch: 1 = Protocol 1
SW11 … SW24
SW11
SW12
SW13
SW14
SW15
SW16
SW17
SW18
SW21
SW22
SW23
SW24
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
=
=
=
=
=
=
=
=
=
=
=
=
RS232
Data length = 8 bits
}
Baud rate = 9600
Parity check disabled
Not used
1 Stop bit
Sum check enabled
Write during RUN enabled
Not used
Not used
Settings for A1SJ71C24-R2
Mode switch: 1 = Protocol 1
SW03 … SW12
SW03
SW04
SW05
SW06
SW07
SW08
SW09
SW10
SW11
SW12
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
=
=
=
=
=
=
=
=
=
=
Not used
Write during RUN enabled
}
Baud rate = 9600
Data length = 8 bits
Parity check disabled
Not used
1 Stop bit
Sum check enabled
GX IEC Developer Reference Manual 8 – 39
Modem settings for GSM Modems Compiling and Downloading Programs
Environment: Analogue Modem -> GSM Modem -> A(1S)J71(U)C24
MIM-A01 MIM-G01
Standard
RS232 cable (1:1)
Fig. 8-45:
Environment
Standard
RS232 cable (1:1)
PLC
A-Series
Analogue Modem settings:
AT E0
&S0
&D0
&K0
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
+CPIN=____ (PIN No. of SIM card)
8 – 40
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-46:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-47:
Setting the communication details
GX IEC Developer Reference Manual 8 – 41
Modem settings for GSM Modems Compiling and Downloading Programs
햶 Double click on PLC side I/F - C24 to open the dialogue box PLC side I/F Detailed
setting of C24 and set the details.
Fig. 8-48:
Detailed setting for the C24
NOTE
To connect the modems, the WINDOWS Hyperterminal has to be used.
The GX IEC Developer function Connect Line does not work in this case.
8 – 42
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
Environment: GSM Modem -> GSM Modem -> A(1S)J71(U)C24
MIM-G01 MIM-G01
PLC
A-Series
Standard
RS232 cable (1:1)
Fig. 8-49:
Environment
Standard
RS232 cable (1:1)
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
+CPIN=____ (PIN No. of SIM card)
GX IEC Developer Reference Manual 8 – 43
Modem settings for GSM Modems Compiling and Downloading Programs
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
8 – 44
Fig. 8-50:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig: 8-51:
Setting the communication details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
햶 Double click on PLC side I/F - C24 to open the dialogue box PLC side I/F Detailed
setting of C24 and set the details.
Fig. 8-52:
Detailed setting for the C24
NOTE
To connect the modems, the WINDOWS Hyperterminal has to be used.
The GX IEC Developer function Connect Line does not work in this case.
GX IEC Developer Reference Manual 8 – 45
Modem settings for GSM Modems
8.5.5
Compiling and Downloading Programs
A-Series – Communication via MAC (Transparent Mode)
Settings for MAC Terminal:
Fig. 8-53:
Setting the peripheral configuration in the E-Designer
8 – 46
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
Environment: Analogue Modem -> GSM Modem -> MAC -> A-Series Progr. Port
Standard
RS232 cable (1:1)
MIM-A01 MIM-G01
Crossed cable
1 --- 1
2 --- 3
3 --- 2
4 --- 6
5 --- 5
6 --- 4
7 --- 8
8 --- 7
MAC
Standard MAC cable
PLC
A-Series
Fig. 8-54:
Environment
Analogue Modem settings:
AT E0
&S0
&D0
&K0
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
&W
+CPIN=____ (PIN No. of SIM card)
GX IEC Developer Reference Manual 8 – 47
Modem settings for GSM Modems Compiling and Downloading Programs
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
8 – 48
Fig. 8-55:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-56:
Setting the communication details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
햶 Double click on PLC side I/F - PLC Modul to open the dialogue box PLC side I/F
Detailed setting of PLC module and set the communication mode.
Fig. 8-57:
Setting the communication mode
햷 Select Line Connected, enter the Call number of the remote modem and click
Connect.
Fig. 8-58:
Set up the connection
햸 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
GX IEC Developer Reference Manual 8 – 49
Modem settings for GSM Modems Compiling and Downloading Programs
Environment: GSM Modem -> GSM Modem -> MAC -> A-Series Progr. Port
Standard
RS232 cable (1:1)
MIM-G01
MIM-G01
Crossed cable
1 --- 1
2 --- 3
3 --- 2
4 --- 6
5 --- 5
6 --- 4
7 --- 8
8 --- 7
MAC
Standard MAC cable
PLC
A-Series
Fig. 8-59:
Environment
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
&W
+CPIN=____ (PIN No. of SIM card)
8 – 50
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-60:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-61:
Setting the communication details
GX IEC Developer Reference Manual 8 – 51
Modem settings for GSM Modems Compiling and Downloading Programs
햶 Double click on PLC side I/F - PLC Modul to open the dialogue box PLC side I/F
Detailed setting of PLC module and set the communication mode.
Fig. 8-62:
Setting the communication mode
햷 Select Line Connected, enter the Call number of the remote modem and click
Connect.
8 – 52
Fig. 8-63:
Set up the connection
햸 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
MITSUBISHI ELECTRIC
Modem settings for GSM Modems Compiling and Downloading Programs
8.5.6
QnA-Series – Communication with C24
Settings for AJ71QC24N or A1SJ71QC24-R2
Mode switch: 5 = Binary mode Format 5
SW01 … SW12
SW01
SW02
SW03
SW04
SW05
SW06
SW07
SW08
SW09
SW10
SW11
SW12
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
=
=
=
=
=
=
=
=
=
=
=
= always OFF
Data length = 8 bits
Parity check disabled
Not used
1 Stop bit
Sum check enabled
Write during RUN enabled
Changes enabled (allow)
}
Baud rate = 9600
GX IEC Developer Reference Manual 8 – 53
Modem settings for GSM Modems Compiling and Downloading Programs
Environment: Analogue Modem -> GSM Modem -> A(1S)J71QC24
MIM-A01 MIM-G01
Standard
RS232 cable (1:1)
Fig. 8-64:
Environment
Standard
RS232 cable (1:1)
PLC
QnA-Series
Analogue Modem settings:
AT E0
&S0
&D0
&K0
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
+CPIN=____ (PIN No. of SIM card)
8 – 54
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-65:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-66:
Setting the communication details
GX IEC Developer Reference Manual 8 – 55
Modem settings for GSM Modems Compiling and Downloading Programs
햶 Double click on PLC side I/F - C24 to open the dialogue box PLC side I/F Detailed
setting of C24 and set the details.
Fig. 8-67:
Detailed setting for the C24
NOTE
To connect the modems, the WINDOWS Hyperterminal has to be used.
The GX IEC Developer function Connect Line does not work in this case.
8 – 56
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
Environment: GSM Modem -> GSM Modem -> A(1S)J71QC24
MIM-G01 MIM-G01
Standard
RS232 cable (1:1)
Fig. 8-68:
Environment
Standard
RS232 cable (1:1)
PLC
QnA-Series
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
+CPIN=____ (PIN No. of SIM card)
GX IEC Developer Reference Manual 8 – 57
Modem settings for GSM Modems Compiling and Downloading Programs
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
8 – 58
Fig. 8-69:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-70:
Setting the communication details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
햶 Double click on PLC side I/F - C24 to open the dialogue box PLC side I/F Detailed
setting of C24 and set the details.
Fig. 8-71:
Detailed setting for the C24
NOTE
To connect the modems, the WINDOWS Hyperterminal has to be used.
The GX IEC Developer function Connect Line does not work in this case.
GX IEC Developer Reference Manual 8 – 59
Modem settings for GSM Modems
8.5.7
Compiling and Downloading Programs
QnA-Series – Communication via MAC (Transparent Mode)
Settings for MAC Terminal:
Fig. 8-72:
Setting the peripheral configuration in the E-Designer
8 – 60
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
Environment: Analogue Modem -> GSM Modem -> MAC -> QnA-Series Progr. Port
Standard
RS232 cable (1:1)
MIM-A01 MIM-G01
Crossed cable
1 --- 1
2 --- 3
3 --- 2
4 --- 6
5 --- 5
6 --- 4
7 --- 8
8 --- 7
MAC
Standard MAC cable
PLC
QnA-Series
Fig. 8-73:
Environment
Analogue Modem settings:
AT E0
&S0
&D0
&K0
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
&W
+CPIN=____ (PIN No. of SIM card)
GX IEC Developer Reference Manual 8 – 61
Modem settings for GSM Modems Compiling and Downloading Programs
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
8 – 62
Fig. 8-74:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-75:
Setting the communication details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
햶 Double click on PLC side I/F - PLC Modul to open the dialogue box PLC side I/F
Detailed setting of PLC module and set the communication mode.
Fig. 8-76:
Setting the communication mode
햷 Select Line Connected, enter the Call number of the remote modem and click
Connect.
Fig. 8-77:
Set up the connection
햸 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
GX IEC Developer Reference Manual 8 – 63
Modem settings for GSM Modems Compiling and Downloading Programs
Environment: GSM -> GSM -> MAC -> QnA-Series Progr. Port
Standard
RS232 cable (1:1)
MIM-G01 MIM-G01
Crossed cable
1 --- 1
2 --- 3
3 --- 2
4 --- 6
5 --- 5
6 --- 4
7 --- 8
8 --- 7
MAC
Standard MAC cable
PLC
QnA-Series
Fig. 8-78:
Environment
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
&W
+CPIN=____ (PIN No. of SIM card)
8 – 64
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-79:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-80:
Setting the communication details
GX IEC Developer Reference Manual 8 – 65
Modem settings for GSM Modems Compiling and Downloading Programs
햶 Double click on PLC side I/F - PLC Modul to open the dialogue box PLC side I/F
Detailed setting of PLC module and set the communication mode.
Fig. 8-81:
Setting the communication mode
햷 Select Line Connected, enter the Call number of the remote modem and click
Connect.
8 – 66
Fig. 8-82:
Set up the connection
햸 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
MITSUBISHI ELECTRIC
Compiling and Downloading Programs
8.5.8
Modem settings for GSM Modems
Q-Series – Communication with C24
Settings for QJ71C24-R2
When using the QJ71C24-R2 you first have to do the following settings:
햲 Open the Parameter dialogue and select the tab I/O assignment.
Fig. 8-83:
Tab I/O assignment of the PLC Parameter dialogue
GX IEC Developer Reference Manual 8 – 67
Modem settings for GSM Modems Compiling and Downloading Programs
햳 Click on the button Switch setting to open the following dialogue.
8 – 68
Fig. 8-84:
Input the switch settings for the module
햴 Set the following switches:
Switch 1:
CH1 Communication and Transmission setting
Switch 2:
CH1 Communication protocol setting
Switch 3: CH2 Communication and Transmission setting
Switch 4: CH2 Communication protocol setting
Switch 5: Station number setting
햵 Click on the button End to save the settings.
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
Environment: Analogue Modem -> GSM Modem -> QJ71C24-R2
MIM-A01 MIM-G01
Standard
RS232 cable (1:1)
Fig. 8-85:
Environment
Standard
RS232 cable (1:1)
PLC
Q-Series
Analogue Modem settings:
AT E0
&S0
&D0
&K0
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
+CPIN=____ (PIN No. of SIM card)
GX IEC Developer Reference Manual 8 – 69
Modem settings for GSM Modems Compiling and Downloading Programs
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-86:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
8 – 70
Fig. 8-87:
Setting the communication details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
햶 Double click on PLC side I/F - C24 to open the dialogue box PLC side I/F Detailed
setting of C24 and set the details.
Fig. 8-88:
Detailed setting for the C24
햷 Select Line Connected, enter the Call number of the remote modem and click
Connect.
Fig. 8-89:
Set up the connection
햸 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
GX IEC Developer Reference Manual 8 – 71
Modem settings for GSM Modems Compiling and Downloading Programs
Environment: GSM Modem -> GSM Modem -> QJ71C24-R2
MIM-G01 MIM-G01
Standard
RS232 cable (1:1)
Fig. 8-90:
Environment
Standard
RS232 cable (1:1)
PLC
Q-Series
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
+CPIN=____ (PIN No. of SIM card)
8 – 72
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-91:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-92:
Setting the communication details
GX IEC Developer Reference Manual 8 – 73
Modem settings for GSM Modems Compiling and Downloading Programs
햶 Double click on PLC side I/F - C24 to open the dialogue box PLC side I/F Detailed
setting of C24 and set the details.
Fig. 8-93:
Detailed setting for the C24
햷 Select Line Connected, enter the Call number of the remote modem and click
Connect.
8 – 74
Fig. 8-94:
Set up the connection
햸 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
MITSUBISHI ELECTRIC
Compiling and Downloading Programs
8.5.9
Modem settings for GSM Modems
Q-Series – Communication via MAC (Transparent Mode)
Settings for MAC Terminal:
Fig. 8-95:
Setting the peripheral configuration in the E-Designer
GX IEC Developer Reference Manual 8 – 75
Modem settings for GSM Modems Compiling and Downloading Programs
Environment: Analogue Modem -> GSM Modem -> MAC -> Q-Series Progr. Port
MIM-A01
MIM-G01
MAC
PLC
Q-Series
Standard
RS232 cable (1:1)
Crossed cable
1 --- 1
2 --- 3
3 --- 2
4 --- 6
5 --- 5
6 --- 4
7 --- 8
8 --- 7
Standard MAC cable
Fig. 8-96:
Environment
Analogue Modem settings:
AT E0
&S0
&D0
&K0
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
&W
+CPIN=____ (PIN No. of SIM card)
8 – 76
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-97:
Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
Fig. 8-98:
Setting the communication details
GX IEC Developer Reference Manual 8 – 77
Modem settings for GSM Modems Compiling and Downloading Programs
햶 Double click on PLC side I/F - PLC Modul to open the dialogue box PLC side I/F
Detailed setting of PLC module and set the communication mode.
Fig. 8-99:
Setting the communication mode
햷 Select Line Connected, enter the Call number of the remote modem and click
Connect.
8 – 78
Fig. 8-100: Set up the connection
햸 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
Environment: GSM Modem -> GSM Modem -> MAC -> Q-Series Progr. Port
Standard
RS232 cable (1:1)
MIM-G01 MIM-G01
Crossed cable
1 --- 1
2 --- 3
3 --- 2
4 --- 6
5 --- 5
6 --- 4
7 --- 8
8 --- 7
MAC
Standard MAC cable
PLC
Q-Series
Fig. 8-101: Environment
GSM Modem settings:
AT E0
S0=2
&S0
&D0
+CICB=0
+IFC=0,0
+CMEE=1
+IPR=9600
&W
+CPIN=____ (PIN No. of SIM card)
GX IEC Developer Reference Manual 8 – 79
Modem settings for GSM Modems Compiling and Downloading Programs
GX IEC Developer settings:
햲 Select Transfer Setup in the Online menu, then select Ports from the submenu displayed.
햳 Set the value for the option Time out (� in the following dialogue window) to ≥ 15 sec.
�
Fig. 8-102: Setting in the menu Transfer Setup
햴 Double click on PC side I/F - Serial to open the dialogue box PC side I/F Serial setting and set the connection details.
햵 Select Setup to open the dialogue Transfer Setup: PC side I/F Serial Setting to set up further communication details.
8 – 80
Fig. 8-103: Setting the communication details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Modem settings for GSM Modems
햶 Double click on PLC side I/F - PLC Modul to open the dialogue box PLC side I/F
Detailed setting of PLC module and set the communication mode.
Fig. 8-104:
Setting the communication mode
햷 Select Line Connected, enter the Call number of the remote modem and click
Connect.
Fig. 8-105: Set up the connection
햸 If the connection was successful, a message box shows:
– Connect completed
– Destination – 0123456789
ß Call number of your remote modem
GX IEC Developer Reference Manual 8 – 81
Modem settings for GSM Modems
8.5.10
Compiling and Downloading Programs
Special Remarks on using GSM modems
GSM modem synchronisation
Some modems, mainly GSM modems, do not work with the standard communication settings.
In such cases the (GSM) modem often needs some time between retries while communicating. This time to wait between retries we call modem synchronisation time, which can be enabled and set in this functionality.
Fig. 8-106: Menu item under Online -> Transfer Setup
The menu item is available if a project is open and either MAC transparent mode with CPU port or C24 is selected in the Transfer Setup -> Ports.
Fig. 8-107:
Dialogue
8 – 82
Use GSM modem synchronization: If checked, the synchronization is used. Enter a value in the range of 1 to 60000 ms for synchronization.
Timeout setting for communication initialization
When initializing the connection with the PLC, the timeout setting entered in the Transfer
Setup does not apply to the communication. The timeout value set in the Transfer Setup is used only after the communication has been initialized.
The pre-defined timeout setting is not suitable for GSM communication under specific circumstances, which causes communication failures.
To avoid communication failures when using GSM or other connection types with occasional high delays, it is possible to increase the timeout value used at communication initialization.
When you set a timeout value of 15 seconds or more in the Transfer Setup, this value will be used also when initializing the communication with the PLC. If the timeout value is lower than
15 seconds, the original pre-defined value will be used for communication initialization.
쎲 If the timeout setting is less than 15 seconds, then the performance is not affected.
쎲 If the timeout setting is 15 seconds or greater, then:
– If the connected PLC can be accessed, the performance of the communication initialization is not affected.
– If there is no connected PLC, or the connected PLC cannot be accessed, then at least the time set for timeout must elapse until the communication initialization attempt can finish.
MITSUBISHI ELECTRIC
Compiling and Downloading Programs
8.6
Transfer Setup - Project
Transfer Setup - Project
You can specify precisely which objects and source information in your project you want to download.
Fig. 8-108:
Project transfer setup
NOTES
The option Init System Addresses is set as default when creating a new project. As this is a project specific option, it does not affect the setting in other projects opened, who were created without this option set.
Since the Q Remote I/O module has a Flash ROM drive only, the download function transfers only the parameter and (if selected) the intelligent parameter to drive 4 of the PLC.
Fig. 8-109:
Project transfer setup for a Q Remote I/O module
How to set the transfer settings
햲 In the Online menu select Transfer Setup, then select Project.
햳 Select the desired options in the Download Object and Source Information fields of the dialogue box.
PLC Parameter : Downloads only the PLC configuration data to the PLC CPU.
Program: Downloads only the compiled program code to the PLC.
GX IEC Developer Reference Manual 8 – 83
Transfer Setup - Project Compiling and Downloading Programs
PLC Parameter and Program: Downloads both the configuration data and the compiled program code to the PLC.
Download Intelligent Parameter File (only Q Remote I/O): Downloads the intelligent parameter file to the Remote I/O module.
Drive: Select the PLC CPU drive for the transfer.
Init System Addresses: Initialises all system variables during download. This is done by a direct memory write.
Download Boot (Autoexec) File: Controls the download of the boot file to the PLC. However, if this check box is unchecked, the boot file (if it already exists on the PLC) will be deleted from the PLC during download. For Q00(J)/Q01 PLCs this check box is disabled. To download the boot file to these PLCs, the corresponding check box Do boot from standard ROM in the PLC
Parameters option Boot File has to be checked.
Download Intelligent Parameter File: By checking this option the Intelligent Parameter File
(IPARAM) for Q projects will be downloaded to the PLC.
Symbolic: Downloads the project together with all information, including the POUs not defined in tasks. If a project, which includes the setting
structure
(used in lower MM+ versions), is downloaded the setting will be converted automatically to
symbolic
. This means that the information in the project database will not be changed, but when the information is queried,
structure
will be handled as
symbolic
.
The symbolic download may be encrypted with a password. In the password only alphanumeric characters (a..z, A..Z, 0..9) are accepted.
No Information: Downloads only the binary program code to the CPU.
Drive: Select the PLC CPU drive for the transfer.
MELSEC IL (always drive 0): Reads the binary code from the PLC CPU and creates a POU in
MELSEC IL language with the standard name PRG_MAIN and a task with the standard name
MELSEC_MAIN.
Source information: Reads all the graphical and structural information from the PLC CPU in addition to the binary code.
Drive: Select the PLC CPU drive for the transfer.
Upload Intelligent Parameter File: By checking this option the Intelligent Parameter File
(IPARAM) for Q projects will be uploaded from the PLC.
햴 Confirm your selections with OK.
E
WARNING:
The first time you download a new project it is important to ensure that the option PLC
Parameter and Program is selected.
8 – 84
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Transfer Setup - Project
Available drives
The following table lists all drives and their respective availability for the following functions in the menu Project - Transfer:
Upload from PLC, Download to PLC, Copy Program Memory to Flash ROM.
Drive
0
1
2
Type
Upload
Download
Type
Upload
Download
Copy destination
Type
Upload
Download
Copy destination
3
4
Type
Upload
Download
Copy destination
Type
Upload
Download
Copy destination
Q Q00(J)/Q01
Program memory
앬
앬
Memory card RAM not available
앬
앬
—
Program memory
앬
앬
Memory card ROM not available
앬
앬
앬
(flash ROM card only)
Standard RAM Standard RAM
(used for automatically defined file registers)
—
—
—
Standard ROM
앬
앬
앬
—
—
—
Standard ROM
앬
—
햲
앬
Tab. 8-3:
Available PLC CPU drives
QnA
Internal RAM
앬
앬
IC card A RAM
앬
앬
—
IC card A ROM
앬
앬
—
IC card B RAM
앬
앬
—
IC card B ROM
앬
앬
—
—
—
—
—
—
—
—
—
Q Remote I/O
—
—
—
—
—
—
—
Flash ROM
쎲
쎲
쎲
앬 Supported
— Not supported
햲
Direct download of the project to a flash ROM is not supported for the Q00(J)/Q01 CPUs. A project can be transferred to drive 4 by downloading it to the program memory and then copying the program memory to the flash ROM.
GX IEC Developer Reference Manual 8 – 85
Transfer Setup - Project
8.6.1
Compiling and Downloading Programs
Downloading the Intelligent Parameter file for Q projects
The download of the Intelligent Parameter (IPARAM) file for a Q project is handled by the dialogues PLC Parameter Boot Settings and Project Transfer Setup. The file IPARAM is part of the GX IEC Developer project. It is located in the subfolder Resource of the project folder.
PLC Parameter
NOTE
Fig. 8-110: Boot file setting
The Intelligent Parameter file is added to the Boot file setting list automatically. Additionally, editing the “Boot file setting” list is enabled. This causes the following behaviour:
쎲 The column Transfer from is editable for all entries, allowing you to select the drive where the PLC files are transferred from.
쎲 The buttons Insert and Delete are used to insert or delete an entry in the Boot file setting list.
However, in order to preserve consistency in the project, if CONSIST.MMP is removed from the Boot file setting list, it will be re-added automatically as soon as the dialogue is closed.
The Transfer from drive of CONSIST.MMP will be set to the same drive as for the MAIN program.
쎲 An entry for a SFC program will be added or removed automatically during compile, depending on the existence of a SFC program in the project. The Transfer from drive of the SFC program will be set to the same drive as for the MAIN program.
8 – 86
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Transfer Setup - Project
Checking the Boot File before download
If the Boot File is selected for download, its entries will be checked during the initialization of the Download process. The following warning will be displayed if either the Parameter, the
MAIN or (if it exists in the project) the SFC program is missing from the boot File:
Fig. 8-111:
Message
The following warning will be displayed if the Transfer from drive of all entries is not set to the same drive:
Fig. 8-112:
Warning
When the PLC Parameter dialogue is opened, it is automatically checked if the Intelligent
Parameter File exists in the project. If it does, the display of the Boot File setting is modified, so it includes an entry for the Intelligent Parameter File. The Transfer from drive of the Intelligent Parameter File is set to the same drive as for the PLC Parameter.
At the beginning of the Download process, it is checked if the Boot File and the Intelligent
Parameter File are selected to be transferred. If both files were selected, the Boot File will be modified before download to include an entry for the Intelligent Parameter File (if this entry does not exist already).
The Transfer from drive of the Intelligent Parameter File is set to the same drive as for the PLC
Parameter. The existence of the IPARAM file in the project will be checked before download.
If no IPARAM file exists in the project, no entry will be added to the Boot File of the Intelligent
Parameter File. If the entry already exists, it will be removed.
The message Download success will be shown, in order to inform you:
Fig. 8-113:
Download success
GX IEC Developer Reference Manual 8 – 87
Transfer Setup - Project Compiling and Downloading Programs
Download and Upload of the Intelligent Parameter
The dialogue showing the Download results also includes the status of the Intelligent Parameter. If the download of IPARAM was successful, but the download process fails or is aborted later, the following dialogue will be displayed:
Fig. 8-114:
Download results
NOTE
When downloading to both systems of a QnPRH PLC, the redundant version of this dialogue will be used. In this case, the same file is downloaded to both systems (as with all other files during a redundant download).
If the download of the Intelligent Parameter fails because the project does not contain the Intelligent Parameter (IPARAM.WPA) file, the download process will not be interrupted. In this case, the following dialogue will be shown:
Fig. 8-115:
Message
If the download of the Intelligent Parameter fails because of any other reason, the download process will be aborted and the dialogue showing the Download Results will be displayed:
Fig. 8-116:
Download results
8 – 88
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Transfer Setup - Project
If the upload of the Intelligent Parameter fails because the PLC drive does not contain the Intelligent Parameter (IPARAM.QPA) file, the upload process will not be interrupted. In this case, the following dialogue will be displayed:
Fig. 8-117:
Message
If the upload of the Intelligent Parameter fails because of any other reason, the upload process will be aborted and the same dialogue will be displayed as for any other error occurring during the upload:
Fig. 8-118:
Warning
8.6.2
Download symbolic information by menu command
The menu Project - Transfer includes a menu command to download symbolic information of the current project to the PLC. This is independent of the current settings concerning source information in the transfer setup.
This menu command will be shown only when the current PLC type is A/QnA/Q.
In a redundant PLC system in backup mode, the user will be asked (via a confirmation dialogue) if he wants to download symbolic information of the current project to both PLCs.
(Please refer to section 3.7.2 for details of the confirmation dialogue.)
GX IEC Developer Reference Manual 8 – 89
Transfer Setup - Project
8.6.3
Compiling and Downloading Programs
Ignore checks
If the project currently open in GX IEC Developer and the project on the connected PLC have different time stamps, there is the possibility to continue the current action, although the projects are not equal.
Fig. 8-119:
Different project generation times are notified.
This dialogue is used for the following actions:
쎲 Project online program change
쎲 Online change mode
쎲 Download symbolic information
During monitoring the button Ignore Checks is enabled. In this non-critical case the user is allowed to monitor the projects although the projects are not equal. In all other cases the button
Ignore Checks is disabled.
It is not possible to ignore checks when starting a the
online change mode
.
project online program change
or entering
8 – 90
MITSUBISHI ELECTRIC
Compiling and Downloading Programs
8.6.4
Transfer Setup - Project
The Q/QnA’s File Structure
How to format and defragment the Q/QnA series drive
Before you can use the memory in the MELSEC Q/QnA series CPUs you must first format the corresponding drive. This applies both for the internal RAM and the external memory cards.
For details on the available drives refer to the table on page 8-85.
햲 Select Format Drive in the Online menu. The Format / Defragment dialogue box is displayed.
In a redundant PLC system in backup mode, the user will be asked (via a confirmation dialogue) if he wants to format the specified drive of both PLCs. (Please refer to section
3.7.2 for details of the confirmation dialogue.)
Similarly, before defragmenting any of the drives in Backup mode, the user will be asked (via a confirmation dialogue) if he wants to defragment the specified drive of
both systems. (Please refer to section 3.7.2 for details of the confirmation dialogue.)
Fig. 8-120:
Format / Defragment dialogue
0 … 4: Drive to be formatted or defragmented.
Create system area to speed up monitoring...: If a Q/QnA is connected to GX IEC
Developer and a remote Q/QnA is to be monitored, both PLCs (host and remote) have to be formatted with at least 1-K steps system area available in the dialogue Format / Defragment.
If one of both PLCs is not formatted with this system area, the remote Q/QnA cannot be monitored.
Create system area to enable Multi Block Online Changes… : In the CPUs supporting the
MBOC function the number of steps which can be exchanged in the online mode has been expanded to 1024 steps. These 1024 steps do not have to be within one block. It is also possible to make changes in several small blocks. The maximum number of blocks is fixed to
64. However, the number of 1024 steps must not be exceeded (Q series only except Q00(J),
Q01, and QnU CPUs).
Format: Selecting this button starts the format procedure.
Defragment: Because of the file structure used in the Q/QnA series CPUs it is possible for the drives to become fragmented after data have been written to the CPU, just as with a normal hard drive. Selecting the Defragment button executes a procedure that defragments the contents of the drive for better performance.
GX IEC Developer Reference Manual 8 – 91
Transfer Setup - Project Compiling and Downloading Programs
How to get File Information
햲 Select File Info in the Online menu. The File Info dialogue box displays information on the memory and the files in the CPU.
Fig. 8-121:
File information
8 – 92
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Transfer Setup - Project
Fig. 8-122: File information for a redundant system (extended dialog for QnPRH only)
For details on the available drives refer to the table on page 8-85.
Memory usage -
drive
Used memory: Amount of downloaded data (unit: bytes)
Available memory: Amount of memory available for use (unit: bytes)
Largest free block: Largest free memory block available (unit: bytes)
In case this block is not large enough, use the Defrag option.
Execute operations on System ...: If one of the Execute operations check boxes of the extended dialog for the redundant system is unchecked, the corresponding file list will be disabled and any selections removed.
If both of the Execute operations check boxes are unchecked, the Delete, Read and Write buttons will become disabled.
GX IEC Developer Reference Manual 8 – 93
Transfer Setup - Project Compiling and Downloading Programs
MAIN program -
drive
Generated with version: Displays the version of GID that was used to generate the program
– Version string extracted from MAIN.QPG
– “n/a” if there’s no program, or it was not generated with GX IEC Developer
Generation time: Displays the generation time of the program
– Generation time extracted from the consistency information (CONSIST.MMP)
(*)
– “n/a” if there’s no program or no consistency information
NOTES
Files
0 … 4: Files stored in the program memory (Drive 0), in the RAM or ROM of the memory card
(Drives 1 and 2), and in the standard RAM or standard ROM (Drives 3 and 4).
Full details on the file structure used by the MELSEC Q/QnA series CPUs can be found in the CPU manuals.
The extended dialog for the redundant system is used in Backup and Separate mode if both systems are accessible. In Debug mode, or if the other system is not accessible, the standard version of this dialog is used.
Transfer files between personal computer and PLC
From the File Info dialogue selected PLC files can be transferred from the PLC drives to the hard disk of your personal computer and vice versa. They can also be deleted. Multiple files can be selected via mouse-click in combination with the [CTRL] or [SHIFT] key.
This function is for example useful for storing the documentation of the currently running process on a PLC drive to make it always available.
Delete file(s)
Deletes the selected files from the PLC. Multiple files can only be deleted from one single drive.
Only files can be deleted (not drives etc.).
Read from PLC
Reads the selected files from the PLC. A standard file dialogue is opened where you specify the destination folder for the selected PLC file(s) on your hard disk. Multiple files can only be read from one single drive.
Write to PLC
Writes the selected files to the selected PLC drive. A standard file dialogue is opened where you specify the source file(s) on your hard disk. Multiple files can only be written from one single directory. Writing to flash ROM drives is not supported.
8 – 94
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Transfer Setup - Project
Remarks on stopping and restarting the PLC during the "Write to PLC" operation
Some files (e.g. Program and Parameter files) cannot be written to Q and QnA PLCs via the
File Info dialogue when the PLC is in RUN mode. In previous versions of GX IEC Developer, attempting to write such files during RUN failed with an EasySocket error message.
The dialogues Stop PLC and Restart PLC (normaly used to stop and restart the PLC e.g.
during a Delete file operation) can also be used to stop and restart the PLC during a Write to
PLC operation if any system files (i.e. files used by the GX IEC Developer project) are selected.
The following files will be considered to be system files:
쎲 MAIN.QPG
쎲 SFC.QPG or MAIN-SFC.QPG
쎲 PARAM.QPA
쎲 IPARAM.QPA
쎲 SYMPARAM.MMP
쎲 CONSIST.MMP
쎲 SYMBOLIC.MMP
쎲 LIBRARY.MMP
쎲 AUTOEXEC.QBT
쎲 MBOC.QMB
When the first such file is encountered during Write to PLC, the following dialogue will be displayed if the PLC is in RUN mode:
Fig. 8-123:
Warning that PLC will be stopped
When the Write to PLC operation is finished, the following dialogue will be displayed:
Fig. 8-124:
Message about copying result
For QnPRH PLCs in Backup mode, or if both systems are selected in Separate mode, the redundant version of these dialogues will be used:
Fig. 8-125:
Warning that both PLCs of a redundant system will be stopped
Fig. 8-126:
Message about copying result for a redundant system
GX IEC Developer Reference Manual 8 – 95
Transfer Setup - Project
8.6.5
Compiling and Downloading Programs
Copy program memory to flash ROM (MELSEC Q only)
The complete PLC program memory content can be copied to the selected flash ROM drive.
The flash ROM drive can even be unformatted. All files stored on the flash ROM drive are overwritten.
Select the menu item Project - Transfer - Copy Program Memory to Flash ROM to open the following dialogue.
Fig. 8-127:
Copy Program Memory to Flash ROM dialogue
NOTE
Select the desired flash ROM drive and confirm with OK.
In a redundant PLC system in backup mode, the user will be asked (via a confirmation dialogue) if he wants to copy the program memory to the Flash ROMs of both PLCs. (Please
refer to section 3.7.2 for details of the confirmation dialogue.)
Supported flash ROM drives
Only the following drives are supported as copy destinations.
Drive
2
4
Q
Memory card ROM (only flash type supported)
Standard ROM
Q00(J), Q01
not available
Standard ROM
Tab. 8-4:
Available copy destination drives
In case of QnU(D)(E)(H)-series PLCs copying the whole content of Drive 0 (program memory) will be possible only to Drive 2 (memory card ROM), not to Drive 4 (standard
ROM).
8.6.6
Copy Program Cache to Program Memory
This function is only available for the series QnU(D)(E)(H) and is enabled when a project is open.
The QnU(D)(E)(H)-series has a different memory model compared to the Qn(H)-series.
Instead of a single program memory, a QnU(D)(E)(H) CPU has a program memory and a program cache memory.
쎲 The program memory is of Flash-ROM type to store its contents permanently without the need for battery backup.
쎲 The program cache memory is an SRAM that loses its contents when the power is cut.
The only purpose of the program memory is to store the data. When the PLC is switched on or reset, the contents of the program memory is copied to the program cache memory. All files
(parameter, program, symbolic information, etc.) are transferred. Afterwards the
QnU(D)(E)(H) PLC uses the program cache memory in the same sense as a Qn(H)-series
PLC uses the program memory. When switched to RUN mode, it executes the program in the program cache memory.
8 – 96
MITSUBISHI ELECTRIC
Compiling and Downloading Programs
8.6.7
Transfer Setup - Project
When changing the contents of the program cache memory, it is necessary to keep the program cache memory synchronised with the program memory, otherwise the changes would get lost if the power is cut from the CPU. Most of the time the changes in the program cache memory are automatically mirrored to the program memory. For example, when executing the download to PLC operation, data are first written into the program cache memory of the CPU module, and then transferred to the program memory automatically.
However, in case of online program change operations it is possible to disable the automatic mirroring in the Options (see section 2.9.3). The reason for this possibility is that since the program memory is of flash ROM type, its lifecycle is limited to about 100000 writing operations. When online program change is executed frequently, turning off automatic transfer will extend the lifetime of the flash ROM.
In order to give the chance to keep data up to date, the function Project
Transfer Copy
Program Cache to Program Memory… is available to start the transfer from the program cache memory to the program memory manually from GX IEC Developer. For example, it can be used if the last online program change operation was performed without mirroring.
Latch Data Backup
To prolong the life of the battery for the series QnU(D)(E)(H) when the system is stopped for a long period of time it is possible to keep latch data (such as device data or error history) in the standard ROM, which does not need the battery to hold them, as it is a flash memory.
Once the data is backed up, the power of the PLC can be switched off and the data will be held until the power is switched back on, when the data will be restored.
Backup
Calling Online
Latch Data Backup
Backup enables to copy (back up) latch data in the memory.
Fig. 8-128:
Confirmation for backing up data
After confirmation the status of the PLC will be checked. If it is in RUN mode, it has to be switched to STOP. This will be confirmed by the following dialog.
Fig. 8-129:
Confirmation for stopping the PLC
NOTES
Choosing not to stop the PLC will result in terminating the process, and data will not be backed up!
To avoid losing data on the PLC when turning off the PLC after the latch data backup operation, you will be warned if online program change was used while the project was open, and the program memory was not updated with the data in the program cache since then.
GX IEC Developer Reference Manual 8 – 97
Transfer Setup - Project Compiling and Downloading Programs
If the action is performed successfully, a dialog will inform you about finishing.
The BATTERY LED of the CPU will flash in green, signaling that the PLC can be turned off.
Fig. 8-130:
Confirmation message
NOTES
If the backup cannot be performed, a message box with the cause or the list of possible causes will be displayed.
If backup data from a former backup operation already exists in the Standard ROM, it will be automatically overwritten.
Delete
The backup data can be deleted by calling Online
Latch Data Backup Delete Backup
Data. The function can be used if the data will no longer be needed to be stored in the flash memory after restoring.
If the Standard ROM contains data to be deleted, the following confirmation message will be displayed.
Fig. 8-131:
Confirmation message
After confirmation the status of the PLC will be checked. If it is in RUN mode, it has to be switched to STOP. This will be confirmed by the following dialog.
Fig. 8-132:
Confirmation for stopping the PLC
NOTES
If the deletion cannot be performed, a message box with the cause or the list of possible causes will be displayed.
If the action is performed successfully, a dialog will inform you about the completion.
8 – 98
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Transfer Setup - Project
8.6.8
Downloading the Project
When you have checked the port settings and project parameters you can download your project to the controller.
NOTES
How to download the project to the PLC
햲 Select Transfer in the Project menu, then select Download to PLC.
In a redundant PLC system in backup mode, the user will be asked (via a confirmation
dialogue) if he wants to download the project to both PLCs. (Please refer to section 3.7.2 for
details of the confirmation dialogue.)
In case of a Q Remote I/O module the download function transfers only the parameter and (if selected) the intelligent parameter to drive 4 of the PLC.
The progress of the download process will be documented in a status window.
Fig. 8-133:
Status window of the download process
The successful transfer to the PLC is confirmed by a message box.
Check list before downloading
쎲 Has the project been compiled without errors?
쎲 Are the port parameters set properly for the transfer?
쎲 Are the project parameters set correctly?
GX IEC Developer Reference Manual 8 – 99
Comparison and Online Change of Project Data Compiling and Downloading Programs
8.7
8.7.1
NOTE
Comparison and Online Change of Project Data
Consistency
To verify the consistency between the data in the project and on the PLC, the necessary data must be uploaded from the PLC, which can take a long time with large projects.
To provide a quick way to check if the parameter and program data in the project and on the
PLC are identical, consistency information is maintained on the PLC for projects downloaded by GX IEC Developer. The project consistency check is based on the timestamp stored in the consistency information, which represents the time when the program codes were generated.
If there is no consistency information on the PLC, or if it is incorrect (not downloaded by GX IEC
Developer), consistency cannot be determined by this quick method.
Hereafter the exact verification of consistency will be referred to as
verification of consistency by the long method
. The quick consistency check, based on the consistency information downloaded to the PLC, will be referred to as
consistency check
.
checking consistency by the quick method
or
quick
Parameter and program data on the PLC are considered to be consistent with that in the project, if the following conditions are met:
For all PLC types:
쎲 The project is compiled without any error.
쎲 Code generation options and PLC parameter have not been changed in the project since last compilation.
Additionally for Q/QnA series PLC types:
쎲 The parameter in the project and the parameter on the PLC are identical, excluding the parts of the parameter which are modified by the PLC after switching it to RUN mode.
쎲 The main program in the project and the main program on the PLC are identical.
쎲 The SFC program in the project and the SFC program on the PLC are identical (if SFC program exists in the project), considering SFC program file headers as well.
When online verification is called to confirm consistency, the boot settings will not be compared. The reason is that differences in the boot settings do not affect the functionalities that require consistency.
Additionally for A series PLC types:
쎲 The parameter in the project and the parameter on the PLC are identical, excluding the parts of the parameter which are modified by the PLC after switching it to RUN mode.
쎲 The main program in the project and the main program on the PLC are identical.
쎲 The timer initial values of the main program are identical in the project and on the PLC.
쎲 The counter initial values of the main program are identical in the project and on the PLC.
쎲 The sub program in the project and the sub program on the PLC are identical (if sub program exists in the project).
쎲 The timer initial values of the sub program are identical in the project and on the PLC (if sub program exists in the project).
쎲 The counter initial values of the sub program are identical in the project and on the PLC (if sub program exists in the project).
쎲 The SFC program in the project and the SFC program on the PLC are identical (if SFC program exists in the project).
8 – 100
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Comparison and Online Change of Project Data
Additionally for FX series PLC types:
쎲 The parameter in the project and the parameter on the PLC are identical, excluding the parts of the parameter which are modified by the PLC after switching it to RUN mode.
쎲 The program in the project and the program on the PLC are identical.
There are situations when the consistency information is wrong, i.e. inconsistency is indicated although the parameter and the program codes are identical, or consistency is indicated although the parameter and/or the program codes are different.
The first case is inconvenient for the user, because he must then verify the consistency by the long method, which can take much longer than the quick consistency check.
The second case is dangerous, because functionalities assuming consistency from the quick check can cause erroneous operations when the data in the project and on the PLC are actually inconsistent.
Solutions for both of these issues are available.
False indication of inconsistency – due to missing or invalid consistency information
It is possible that the consistency information in the PLC’s memory is invalid, or there is no consistency information at all on the PLC. Invalid consistency information means that the data existing in the location of supposed GX IEC Developer consistency information is actually not
GX IEC Developer consistency information.
This can happen, because...
쎲 the project was not downloaded by GX IEC Developer.
쎲 the consistency information on the PLC has been (accidentally) overwritten or deleted by the user.
쎲 the data on the PLC has been changed in an unsupported way (i.e. not by GX IEC
Developer).
쎲 for FX and A PLCs: the PLC has not been switched to RUN mode since last download.
In this case, when a functionality that requires consistency is performed, the user will be presented a dialogue where he is noticed about inconsistency – based on the validity of the consistency information –, and he is offered to verify consistency by the long method. Verifying consistency can take long, so it is desirable to perform it as infrequently as possible.
Fig. 8-134:
Message box
The Online Verify functionality is extended, so that when Project
Transfer
Verify is called, it will determine if the consistency information on the PLC is valid. If the verification finds that all required data in the project is identical with that of the PLC, and there is no valid consistency information on the PLC, the user will be asked whether he wants to download valid consistency information to the PLC. The question will be shown after displaying all the verifica-
tion results in the Verify Result Messages window (please see Tab. 4-6 and Tab. 4-7 for
details on the messages).
GX IEC Developer Reference Manual 8 – 101
Comparison and Online Change of Project Data Compiling and Downloading Programs
Fig. 8-135: Message box
NOTE
(“Drive 0” in the question will be replaced by the drive set in the project transfer setup for Q- and
QnA series PLCs. It will be replaced by “the PLC” for FX- and A series PLCs.)
If the user clicks on Yes, consistency information will be generated and downloaded to the
PLC. As a result, next time when an operation requiring consistency is called, it will be able to detect consistency by the quick method.
This feature is not available when the drive selected for download in the project transfer setup (Online
Transfer Setup
Project) of a Q or QnA series PLC is Flash ROM type.
False indication of inconsistency – due to different program code generation times
When there is valid consistency information on the PLC, it is possible that the program code generation times differ even with identical parameters and program codes. For example if the project is changed and compiled, then changed back and compiled again. In this case, when a functionality that requires consistency is performed, the user will be presented a dialogue where he is noticed about inconsistency – based on code generation times –, and he is offered to verify consistency by the long method. Verifying consistency can take long, so it is desirable to perform it as infrequently as possible.
Fig. 8-136:
Message box
In the current version, when consistency verification is invoked from this dialogue, and it is proved that the parameters and the program codes are identical, the generation times in the consistency information of the project and the PLC will be synchronized, so that next time the quick consistency check will find consistency.
On the other hand, when Project
Transfer
Verify was called, it did not synchronize generation times in the same situation. So the user will be asked whether the consistency information should be updated. The question will be shown after displaying all the verification results in the Verify Result Messages window.
8 – 102
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Comparison and Online Change of Project Data
Fig. 8-137: Message box
If the user clicks on Yes, the generation time of the project will be updated to be the same as the generation time on the PLC. The project has to be saved to keep this change.
False indication of consistency
It is possible that the program code generation times are equal even with different parameters and/or program codes.
It is a rather rare situation, but it can happen if...
쎲 a software other than GX IEC Developer was used to download or change data on the PLC, when the PLC has project data downloaded by GX IEC Developer.
쎲 system files were directly manipulated on the PLC with GX IEC Developer or another software.
It is dangerous to have incorrect consistency information on the PLC, when the parameters and/or the program codes in the project and on the PLC are different. It can easily result in malfunction when an operation – e.g. online program change – falsely assumes consistency by the quick method.
The Online Verify functionality is extended, so that when the user calls Project
Transfer
Verify, such a false indication of consistency will be detected and the user will be asked if the incorrect consistency information should be deleted.
NOTES
Fig. 8-138: Message box
(“Drive 0” in the question will be replaced by the drive set in the project transfer setup for Q- and
QnA series PLCs. It will be replaced by “the PLC” for FX- and A series PLCs.)
If the user clicks on Yes, the consistency information will be removed from the PLC.
This feature is not available when the drive selected for download in the project transfer setup (Online
Transfer Setup
Project) of a Q or QnA series PLC is Flash ROM type.
The FX0 and FX0S PLCs have no consistency information, therefore this functionality is not applicable to FX0 and FX0S PLCs.
Downloading or deleting consistency information in Flash ROM type memories is not supported. This feature is not available when the drive selected for download in the project transfer setup (Online
Transfer Setup
Project) of a Q or QnA series PLC is Flash
ROM type.
GX IEC Developer Reference Manual 8 – 103
Comparison and Online Change of Project Data Compiling and Downloading Programs
8.7.2
NOTE
Comparing the programs in the PLC CPU and GX IEC Developer
The function Online verify in the menu Project - Transfer compares the program code stored in the PLC CPU with the code of the current project compiled by GX IEC Developer.
In a redundant PLC system in backup mode, the user will be asked (via a confirmation
dialogue) if he wants to verify both PLCs. (Please refer to section 3.7.2 for details of the
confirmation dialogue.)
Only sequence code differences are shown. Differences for SFC programs of A series CPUs which will be transferred to the main micro computer area will not be shown.
For a redundant PLC system in backup mode the verify process will display items for both
PLCs in the Verify Result Messages window.
Fig. 8-139:
Verify Result Messages
NOTES
Please see Tab. 4-6 and Tab. 4-7 for details on these messages.
For Online Verify the message Boot file not found is displayed, if there is no boot file in the project on the PLC compared with.
Detected differences in the program code can be shown in a Main or Sub Program Differ-
ence window via the Show button. The verify results are listed as recompiled MELSEC IL, the differences are highlighted in the error color. The left part of the window lists the project code, the right part of the window lists the uploaded PLC code.
8 – 104
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Comparison and Online Change of Project Data
When the Main or Sub Program Difference window is opened the following menu items are available in the Tools menu:
Next Difference: Next Difference or the tabulator key will position the text in the window so that the first line of the next difference is the top most line. The top most line will be selected.
The according calltree, number of network and for IL and ST the line in the network of the selected line are shown in the status bar. If no next difference exists, the menu item is greyed.
Previous Difference: Previous Difference or the shift tabulator key will position the text in the window so that the first line of the previous difference is the top most line. The top most line will be selected. The according calltree, number of network and for IL and ST the line in the network of the selected line are shown in the status bar. If no previous difference exists, the menu item is greyed.
Goto Editor: Goto Editor or a double click on a selected line will open the according POU body. In IL/ ST the according line and in LD/ FBD the according network is positioned to the visible area and marked with the browser colour in the network column.
If no POU body relates to the selected line a message window is opened to inform you of this circumstance. The message text will be “The selected line belongs to code generated for task or program handling. No editor could be opened.”
Show Step Number: This menu item is checked as default. If it is checked, the step number for each instruction for the code of the project and of the PLC are displayed.
If it is not checked, the step number are not displayed. If a line is selected and the step number are not displayed, the line is marked with a small box in front of the instruction.
GX IEC Developer Reference Manual 8 – 105
Comparison and Online Change of Project Data
8.7.3
Compiling and Downloading Programs
Online Changes
There are three different ways to make changes to programs when the controller is in RUN mode:
Project – Online Program Change and Online Program Exchange respectively:
These options compile the whole modified program and transfer it to the PLC.
Online – Online Change Mode:
Selecting this option compiles changes made in a program network and directly transfers them to the PLC.
Tool for the menu command Online - Online Change Mode
In general Online Change only works if the compiled program codes in the project and the PLC are identical. After the project is changed and compiled, online change cannot be performed, because the compiled program codes are different in the actual project and on the PLC. In this case the projects in GX IEC Developer and on the PLC are called inconsistent (
will be shown the following dialogue when an online change is attempted:
Fig. 8-140:
Message window
This result is based on the comparison of the generation times of the program codes in the project and on the PLC (
The generation times can differ even if the program codes are identical (e.g. when the project is changed, compiled and then changed back to its original state and compiled again). The
Verify button can be used to check if the program codes and the parameter are really different.
If the parameter and the program codes turn out to be identical, online change will be performed.
Online program change needs to compare the differences between the old and the new program codes. If the two projects are inconsistent, the old program code exists only on the
PLC, not in the project, so the new program code cannot be compared with the old one.
When the parameters in the actual project and on the PLC don’t differ, the program code on the
PLC can be uploaded and used as “old code” to be compared with the new code when online program change is prepared. This way it will be possible to perform an online change even if
(an accidental) Rebuild was called before.
8 – 106
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Comparison and Online Change of Project Data
After pressing the Verify button in the consistency dialogue shown above, if the inconsistency is confirmed, you will be warned and asked whether you still want to perform online program change.
Fig. 8-141: Dialogue box to inform about inconsistency
NOTES
If you click on Yes, online change will be performed by comparing the newly compiled code with the old code that is uploaded from the PLC before – provided that the other usual checks preceding an online change are passed (see below). Depending on the circumstances (e.g.
too big code parts to be changed), it is possible that online exchange will be applied – just like in the case of a consistent project. And in specific cases (e.g. when changing both SFC and
Main programs with step deletion in the SFC program or when the connected PLC does not support online exchange), it will be possible that online change will be denied – just like in the case of a consistent project.
In the case that online change (or online exchange) is executed, the actual project and the project on the PLC will be consistent after that. Consecutive online changes can be completed normally, without the above described handling.
You can set if online change should be available when inconsistency is found. Please see
section 2.9.3 for the related Options setting.
In Backup mode only the control system has to be in RUN mode for Online Change. The standby system may be in either RUN or STOP mode. However, if the standby system is in
FILE VERIFY ERROR (6000 or 6001), an error message will be displayed and Online
Change will be aborted.
In backup mode Online Program Change will only be executed if the registered keyword (if any) is the same on both PLCs. If there’s a mismatch, an error message will be displayed, and Online Change will be aborted.
In Backup mode Online Program Change will only be executed if the size of the additional program size area is the same on both PLCs. (For details on setting the additional program
size please refer to section 2.9.3.) If there’s a mismatch, an error message will be displayed,
and Online Change will be aborted.
If in a redundant system the current additional program size area is exceeded during online program change, the number of necessary additional steps will be calculated. If either of the
PLCs has not enough free space in Program Memory for the necessary additional steps, an error message will be displayed, and Online Change will be aborted.
GX IEC Developer Reference Manual 8 – 107
Comparison and Online Change of Project Data Compiling and Downloading Programs
NOTE
Project – Online Program Change/Online Program Exchange
This function enables you to make changes to the program while the system is in RUN mode.
The edited program is recompiled automatically and compared with the code in the PLC CPU.
Only the altered part of the program code is downloaded to the CPU.
Online changes are possible using the Single Block Online Change (SBOC) function or the Multiple Block Online Change (MBOC) function which is available for MELSEC Q/QnA series’ CPUs (from release date 03.1999 on). The MBOC function is not available in the
Q4ARCPU.
Limitations for FX CPUs
For the FX family, there are the following restrictions regarding the kind of changes you can apply on the program with Online Program Change:
쎲 No newly added, deleted or changed (replaced) pointer or interrupt labels (P and I) are allowed.
쎲 No used pointer or interrupt label (P and I) may be shifted up or down due to a change in the size of the program code.
쎲 No pointer or interrupt label (P and I) may be included in the changed part of a program.
쎲 No newly added or deleted start or reset of high speed counters is allowed.
쎲 No newly added start of 1 ms timers is allowed.
쎲 No newly added or deleted instructions MNET(P), ANRD(P), ANWR(P), RMST,
(D)RMWR(P), (D)RMRD(P), RMMN(P), BLK(P) or MCDE(P) are allowed.
Limitations for FX3U CPUs
For the FX3U there are fewer limitations than for other FX PLCs. The restrictions for FX3U are:
쎲 No newly added, deleted or changed (replaced) pointer or interrupt labels (P and I) are allowed.
쎲 No newly added or deleted start or reset of high speed counters is allowed.
쎲 No newly added start of 1 ms timers is allowed.
쎲 No newly added or deleted instructions DTBL, WBFM, RBFM or (D)SORT2 are allowed.
When online program change is not possible because one or more restricted changes have been made to the program, the reason(s) will be displayed in the following dialogue and online program change will be aborted.
Fig. 8-142:
Message window in case of a FX3U CPU
8 – 108
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Comparison and Online Change of Project Data
Online Program Exchange is an extension to Online Program Change and Online Change
Mode. If the difference between the old and the new main/SFC program exceeds the step-limit of normal online change (both SBOC and MBOC if available), you will be offered to use Online
Program Exchange to perform the change on the respective program type.
If you then chooses not to do so, online change will recover, as it does when the step-limit is exceeded. The Online Program Change will not be executed then.
Fig. 8-143: Dialogue box to inform about program exchange
(for a QnH CPU other than Q02H)
Fig. 8-144: Dialogue box to inform about program exchange
(for a Q02H CPU)
GX IEC Developer Reference Manual 8 – 109
Comparison and Online Change of Project Data Compiling and Downloading Programs
Fig. 8-145: Dialogue box to inform about program exchange
(for a Q25SS CPU)
Fig. 8-146: Dialogue box to inform about program exchange
(if the SFC structure has been changed)
Pressing the Details button shows the following dialogue box:
8 – 110
Fig. 8-147: Dialogue box Warning Details
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Comparison and Online Change of Project Data
NOTE
PLCs of the MELSEC Q series support Online Program Exchange. This means that while the
PLC is in RUN mode, the main program on drive 0 (program memory) of the PLC will completely be replaced with the one you are working on. The advantage of this functionality compared to the normal Online Program Change is that it allows a significantly larger number of steps to be changed at once than using the Online Program Change.
The advantage of the project download is that there is no need to stop the PLC.
Nevertheless it is recommended to use Online Program Change instead of Online Program
Exchange if the applicable differences can be handled by Online Program Change, as it needs less free memory and time.
Qn(H) CPUs from version B4 onward support Online Program Change of the SFC program. Online Program Exchange is supported as well. SFC online change with older
CPU versions will work just like before: if normal Online Program Change cannot be performed, the online change process will be aborted.
The following table shows the availability of main program and SFC program online exchange on specific CPUs of the Q-series:
CPU
Q02(H), Q06H, Q12H, Q25H
Q12PH, Q25PH
Q25SS
Q00(J), Q01
Support of main program exchange
✔
✔
✔
—
Tab. 8-5:
Support of Online Program Exchange
Support of
SFC program exchange
from version B4 on
—
—
—
So in the case of a SFC program when online change fails, online exchange can be performed.
If the structure of at least one SFC POU was modified, online exchange will be offered – provided that the version of the CPU is detected to be at least B4.
When executing Online Program Exchange first the compiled main/SFC program is downloaded to the PLC’s memory, then MAIN.QPG/SFC.QPG in the program memory is overwritten with the downloaded file. For this program exchange there must be enough free space for the new program code while the old MAIN.QPG/SFC.QPG is still in memory. This free space can be either in the program memory or in a SRAM or ATA memory card (provided that the size of the downloaded file is not greater than the size of the exchanged file and the free memory space in the program memory altogether).
If there is not enough free space on drive 0, an installed memory card is automatically used instead.
If both programs have to be exchanged, the main and the SFC program are exchanged separately, so there must be enough free space for the bigger program for a successful online exchange.
After Online Program Exchange a SFC program is not automatically restarted by the PLC
(except for block 0, if the “Autostart block 0” option is set in the SFC Parameters).
Therefore, for Q Series PLCs, the code generated when SFC POUs are used in a project, the last SFC block (BL319) is generated as an SFC control block, which is used to restart all SFC blocks after an Online Exchange.
If this control block could not be generated (because the project already used SFC block 319), a warning will be displayed during SFC Online Exchange.
GX IEC Developer Reference Manual 8 – 111
Comparison and Online Change of Project Data Compiling and Downloading Programs
E
CAUTION
- Performing an Online Program Exchange affects the behaviour of the PLC.
- Controls are stopped during the program exchange interval and outputs are not changed, which may be dangerous in some situations.
NOTES
The scan time of the first cycle after finishing the program exchange will be increased by approximately
- 1.2 ms/kSteps on QnH CPU and
- 2.9 ms/kSteps on Qn CPU if there is enough space in the program memory to perform the exchange.
If a SRAM card is needed for the operation, the scan time will be increased by approximately
- 2.3 ms/kSteps on QnH CPU and
- 4.8 ms/kSteps on Qn CPU.
If an ATA card is needed for the operation, the scan time will be increased by approximately
50 ms/kSteps.
While Online Program Exchange is in progress, an instruction to make access to a file is not executed.
The following conditions have to be fulfilled to start the Online Program Exchange:
쎲 Online Program Change must fail because of exceeding the step-limit of both SBOC and
MBOC (if available), or because of the SFC structure change.
쎲 There must be enough space on drive 0 for the new program(s) (with the old program(s) considered as free space, since they will be replaced)
쎲 There must be enough space on drive 0 or a memory card for the new program file (with the old program file still in memory). If both main and SFC programs get exchanged, there must be enough space for the bigger one of them.
Online Program Exchange is not available in the following situations:
쎲 Too many changed labels and/or interrupt labels
쎲 The CHK CHKST, CHKCIR or CHKEND instruction could not be changed, added or deleted.
Changes between the CHKST and CHK, or between the CHKCIR and CHKEND instructions are not allowed.
8 – 112
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Comparison and Online Change of Project Data
NOTES
Online – Online Change Mode
Online Change Mode is different to the options for compiling the project or Online Program
Change. In this mode, as soon as you make a change to a network a program verify is performed and the change is then written directly to the PLC. This ensures maximum program consistency and security.
After an online change has been made GX IEC Developer checks whether symbolic source information is selected in the transfer setup. If this is the case, you will be asked whether you want to download symbolic information. This dialogue can be disabled for the current GX IEC
Developer session.
If you do not want to download any symbolic information or the option selected in the transfer setup, symbolic information is deleted on the PLC.
no information
is
You should only ever make changes to
one
contiguous program range in the PLC at a time, and the range should not be too large. If you want to be absolutely sure that you are not modifying excessively large sections it is advisable to use
Online Change Mode
, as this mode only permits you to make changes to one network at a time. After every change made to a network the system automatically performs a program compare and transfers the modification directly to the PLC. This approach ensures maximum program consistency and security.
In FX0 CPUs you can only change counters and timers when the PLC is in RUN mode.
Add new network
In the Online Change Mode new networks can be added to programs of the type IL, LD, FBD, and MIL in the editors. To add a new network, in the Edit menu select New Network. From the opening submenu select where to insert the new network: Top, Before, After, Bottom.
In the ST editor (Structured Text) online changes can be performed in the network.
Creation or Update of a Variable
In Online Change Mode the Variable Selection Dialog can be opened and a new variable can be created or an existing one can be changed. The according POU or a GVL is saved in the database immediately.
But these changes can not be undone when the Online Change Mode is left. Because of this a confirmation message is displayed when you create a new variable or update an existing variable in the POU header or a GVL in Online Change Mode.
Fig. 8-148: Dialogue box to warn you
GX IEC Developer Reference Manual 8 – 113
Comparison and Online Change of Project Data Compiling and Downloading Programs
Recover Online Changes
If the online change fails or it is cancelled by the user, a message box appears giving three options. In case a variable was created or changed an Undo is not possible. The Undo button is grayed then.
Fig. 8-149:
Online Change failed
Undo
The changes recently made are rejected and the unmodified network saved at the beginning is recovered. GX IEC Developer remains in online change mode. Additional Undo/Redo in the menu Edit is not possible.
Continue
The changes recently made are kept and you have the possibility to correct the faulty network manually. Recent changes can be restored by means of the functions Edit - Undo and Edit -
Redo.
GX IEC Developer remains in online change mode.
Abort
The changes recently made are kept and the online change mode will be left. Recent changes can be restored by means of the functions Edit - Undo and Edit - Redo.
Via mouse clicks to the navigator area the online change mode will be left.
If you have made changes, you are asked whether you want to remain in the online change mode. Additionally you have the option to undo the changes which have already been done.
In case a variable was created or changed an Undo is not possible. The Undo button is grayed then.
8 – 114
Fig. 8-150: Changes notification
MITSUBISHI ELECTRIC
Compiling and Downloading Programs
8.7.4
Comparison and Online Change of Project Data
Code Generation Options
In the Extras - Options menu the Code Generation command is available (refer to 2.9.1).
The file structure used in the CPUs of the MELSEC Q series makes it necessary to define an additional program range (in units of steps) for online changes when you are using these controllers.
Transfer from Program Cache to Program Memory after Online
Program (Ex)Change
Normally the functionalities Online Program Change and Online Program Exchange apply the modifications to the program cache, then the changes are automatically transferred to the program memory. In case of the Series QnU(D)(E)(H) the program memory is of flash ROM type, so its lifecycle is limited to about 100000 writing operations.
When Online Program (Ex)Change is executed frequently, the automatic transfer to the program memory can be turned off in the Options (see Section 2.9.3), to extend the lifetime of the flash ROM.
When the automatic transfer to program memory is turned off, you will be asked after each online (ex)change operation whether the changes should be transferred.
Fig. 8-151:
Changes notification
NOTE
It is important that the Program Memory is updated when all changes are applied to the PLC.
Even if you forget to transfer the Program Cache to the Program Memory after the last online program (ex)change operation, it is possible to initiate the transfer explicitly via the menu item Project
Transfer
Copy Program Cache to Program Memory… (see Section
8.6.6).
GX IEC Developer Reference Manual 8 – 115
Exporting
8.8
8.8.1
8.8.2
Compiling and Downloading Programs
Exporting
When you perform an import/export both the PLC program data and all the parameter settings are now imported and exported.
Exporting an GX IEC Developer project into an ASCII file
You can export and save the contents of your projects in ASCII format for archiving or to provide the information to others. The ASCII file contains all the project data and has the added advantage that it takes up significantly less storage space than the contents of a complete project directory.
How to export the entire project
햲 Select the command Other in the Project menu, then select Export.
A dialogue box is displayed.
햳 Enter the name for the ASCII file.
햴 Click on the OK button.
The progress of the export process is documented in a status window.
How to export individual objects
햲 Select the objects in Project Navigator you wish to export.
햳 Select the command Export in the Object menu.
A dialogue box is displayed.
햴 Enter the name for the ASCII file.
햵 Click on the OK button.
The progress of the export process is documented in a status window.
Export to EPROM
This function stores an ASCII file in Motorola format which can then be used to program PLC
EPROMS with a standard EPROM programmer. Every line in the ASCII file contains the corresponding hardware address and values. The Export to EPROM command is in the
Other submenu of the Project menu.
8 – 116
MITSUBISHI ELECTRIC
Compiling and Downloading Programs
8.8.3
Exporting
CSV variable export
The menu item Extras - Export Variables exports all variables defined in the GVL and the
POU header of a project in the CSV (Comma Separated Variables) format into a text file. This file can be opened in external tools, e.g. process visualisation or Microsoft Excel.
Before the function is available, the project must be compiled. Besides the variable declarations (including class, identifier, address, type, initial value, comment), the exported file contains general project information (e.g. project name and GX IEC Developer version number).
The options for the CSV variable export can be set under Extras - Options - CSV-Export
GX IEC Developer Reference Manual 8 – 117
Importing Compiling and Downloading Programs
8.9
Importing
When you perform an import/export both the PLC program data and all the parameter settings are now imported and exported.
GX IEC Developer provides a number of data import functions, which are listed briefly below.
Importing Programs from Files
쎲 Import a GX IEC Developer ASCII file
(Project - Other - Import) (Object - Import)
쎲 Import a GX IEC Developer ASCII file
(Tools - Import - GX Developer Network)
쎲 Import a MELSEC print file
(Tools - Import MEDOC Network)
Importing Programs from the PLC CPU
쎲 Symbolic Upload: Upload the project from the PLC CPU, together with all graphical information (Project - Transfer - PLC to MEDOC (Symbolic))
쎲 MELSEC Upload: Upload the project from the PLC CPU in a MELSEC network
(Project - Transfer - PLC to MEDOC (MELSEC))
8.9.1
NOTES
Importing GX IEC Developer ASCII files
A project saved as an ASCII file can be imported selectively. If you do not create a new project before performing the import the selected objects are added to those in the current project.
This applies for all POUs, the tasks, DUTs and the global variables. The import function only works on ASCII files saved with the GX IEC Developer Export function!
You must first create an export file before you can perform an import.
Importing a large ASCII file may take a while without any indication.
The ASCII import functionality is restricted for the Q Remote I/O modules. Files exported from a non-Q Remote I/O project are not allowed to be imported into a Q Remote I/O project.
And files exported from a Q Remote I/O project are not allowed to be imported into a non-Q
Remote I/O project.
How to import the entire project
햲 Select the command Other in the Project menu, then select Import.
A dialogue box is displayed.
햳 Select the desired ASCII file.
햴 Click on the OK button.
The progress of the import process is documented in a status window.
8 – 118
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Importing
How to import individual objects
햲 Select the command Import in the Object menu.
A dialogue box is displayed in which you can select the objects that you wish to import into the new or existing project.
Fig. 8-152:
Import items selection
NOTE
NOTES
In case of a Q Remote I/O module the Import functionality will import only the PLC
Parameter, since Q Remote I/O projects have no other objects. Therefore in the object selection dialogue of the Import functionality all objects except the PLC Parameter will be disabled.
햳 Mark the check boxes of the objects you wish to import.
– Data Unit Types (DUTs)
– Data Units Variables
– POUs
– Global Variables
– Tasks
– PLC Parameter
– User Objects
– User Libraries
햴 Click on the OK button..
A dialogue box is displayed.
햵 Select the desired ASCII file.
햶 Click on the OK button.
The progress of the import process is documented in a status window.
When importing data from an ASCII export file that includes the Global Variable List (e.g. a complete project export), external variables will be automatically removed from POU headers (including POUs in user libraries).
When importing data from an ASCII export file that has no Global Variable List in it, each imported POU header will be checked for external variables. If one or more variables with the class VAR_EXTERNAL or VAR_EXTERNAL_CONSTANT are found, you will be warned that these variables will be skipped.
GX IEC Developer Reference Manual 8 – 119
Importing Compiling and Downloading Programs
8.9.2
NOTE
Importing GX Developer ASCII files
GX Developer (former GPP/WIN) ASCII files can be imported. The ASCII file must have been exported from GX Developer by the separate software package GX Converter.
Open any editor of the type IL or MELSEC IL and select a network. In the Tools menu select the item Import GX Developer Network. Select the required file from GX Developer (text or CSV) to be imported into the selected network.
Functions not supported by GX IEC Developer are ignored during the import (e. g. device comments, initial values, program execution types).
SFC programs can not be imported.
The data to be imported must comply with the following requirements:
Common
The maximum length of an import line is limited to 512 characters.
The width of the different data fields is limited to the following values:
쎲 Step number:
7
쎲 Line statement:
64
쎲 Instruction:
15
쎲 P/I-Statement:
64
쎲 Note:
32
쎲 Device:
15
Text files:
쎲 Text files have to start with a step number followed by a blank (‘ ‘); otherwise the text file is not recognized as a text file
쎲 Line statements have to start with a step number, followed by one or more blanks, followed by a ‘;’ and followed directly with the line statement.
Sample:
7 ;I am a line statement
쎲 Notes may not start with a step number and can be located wherever in the import line;they have to be enclosed by ‘<’ and ‘>’
Sample:
<I am a Note>
쎲 P/I-statements may not start with a step number and can be located wherever in the import line; they have to be enclosed by ‘[’ and ‘]’. Separate Statements must start with a ‘*’ before the ‘[‘.
Sample:
*[I am a separate Statement]
[I am an embedded Statement]
쎲 If a line only contains device data and no statement, the device information must start in column 25, columns 9 to 24 must be blank (‘ ‘)
8 – 120
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Importing
CSV-Files:
쎲 CSV-files have to start with a step number followed by a comma (‘,’), otherwise CSV-Files are not recognised as CSV-Files
쎲 Step numbers must be located in column 1
쎲 Line statements must be located in column 2
쎲 Instructions must be located in column 3
쎲 Devices must be located in column 4
쎲 Column 5 must be empty
쎲 P/I statements must be located in column 6
쎲 Notes must be located in column 7
쎲 Columns 8 and 9 must be empty
쎲 Each line must contain exactly 8 separators
쎲 Notes, line statements and P/I statements, which contain one or more ‘,’ must be enclosed with quotes ‘”’
쎲 Quotes within notes, line statements and P/I statements must be masked with another quote; the whole statements must be enclosed with quotes
쎲 Separate P/I-statements must start with ‘*’
GX IEC Developer Reference Manual 8 – 121
Importing
8.9.3
Compiling and Downloading Programs
Importing MELSEC MEDOC print files
Print files generated by MELSEC MEDOC (DOS version) can be loaded into IEC or MELSEC
Instruction Lists as MELSEC networks. The POU into which you wish to load the file must be open and the network must be selected. Please note that performing this import procedure automatically overwrites the contents of the selected network in the body!
How to import MELSEC MEDOC print files
In MELSEC MEDOC (DOS version):
햲 Select a file name as the printer port. The extension TMP is added to the file name automatically.
햳 Select only the Instruction List and Name List in the program listing. Make sure that the header is switched off!
햴 Start the print procedure.
In GX IEC Developer:
햵 Open the body of a MELSEC Instruction List or create a new MELSEC Instruction List
POU. This new POU must be a Program (PRG).
햶 Select New Network in the Edit menu, then select MELSEC Before from the submenu displayed.
햷 Select Import MELSEC Network in the Tools menu.
햸 In the dialogue box displayed specify the drive and directory where the import file is stored and select the import file (TMP). Confirm your selection with OK. An option box is opened.
GX IEC Developer checks whether the specified file is a valid import file, and whether it contains program code and symbolic names. The default settings displayed in the option box depend on the results of this check. For example, if no symbolic names are found this option will be displayed in light grey and is not selectable.
햹 Confirm the selections with OK.
The progress of the import process is documented in a status window.
MELSEC Program: Import only the program code lines of the Instruction List.
MELSEC Symbolic Names: Import only the Name List. The entries from the list are inserted both in the global variables declaration table and in the header of the POU. Comments after relays and data registers are converted into symbolic names and imported as comments.
When this conversion is performed spaces, quotes and periods are either deleted or replaced with underline characters in accordance with the IEC standard.
8 – 122
MITSUBISHI ELECTRIC
Compiling and Downloading Programs Importing
The translation of the symbolic names can result in duplicate names for some variables. If this happens the following dialogue box is displayed:
Fig. 8-153:
Duplicate variable names notification
8.9.4
The first two entries show the name of the existing variable and the name that the program proposes to use to overwrite this variable.
Replace: Replace the old variable name with the new one.
Repl. all: Replace all existing variable names with new names. If you select this button the program will replace all subsequent variables without prompting.
Skip: Skip this variable name without replacing it. The name is also not added to the Variable
List.
Skip all: Skip all variables with duplicate names and do not add any of them to the Variable
List. If you select this button the program will skip all subsequent duplicate variables without prompting.
Upload PLC to MEDOC
The upload function reads the binary code from the PLC CPU and creates a POU in MELSEC
IL language with the standard name PRG_MAIN and a task with the standard name
MELSEC_MAIN. In addition to the binary code all the graphical and structural information from the PLC CPU can be uploaded.
How to upload project code from the CPU
햲 In the Project menu select Transfer. Then select Upload from PLC.
햳 Select the PLC type and confirm with OK.
햴 The upload must be stored in a new project. Enter the name of the new project to be created in the dialogue box displayed.
햵 Confirm your entry with OK.
햶 A dialogue box is displayed showing a selection of ports for the transfer procedure:
– CPU Port
– Computer Link
– Ethernet
햷 Select the appropriate port for your configuration and confirm with OK.
GX IEC Developer Reference Manual 8 – 123
Importing Compiling and Downloading Programs
햸 A dialogue box is displayed showing a selection of UPLOAD modes:
– MELSEC IL
– Source Information
햹 Select the required UPLOAD mode and confirm with OK.
When you select symbolic source information to be uploaded from the PLC, GX IEC
Developer will check whether symbolic information is available on the PLC.
The progress of the import procedure is documented in a status window.
Absolute Label
Absolute labels are used as jump destinations when PLC programs are uploaded in GX IEC
Developer. Absolute labels are specific pointer addresses (e.g. P20). Every program section identified with a pointer in the original PLC program is loaded to a separate MELSEC network.
Fig. 8-154:
The absolute label is P_20
NOTE
Absolute labels can also be assigned by the user, but you must be very careful to use the correct syntax. Only addresses with the format P – underline – address are interpreted as absolute labels.
P_20
P20
Reference to pointer P20 (absolute label)
Reference to a free pointer P
** (not an absolute label)
The labels with the format LAB_20 generated when you import MELSEC MEDOC print files are not absolute labels!
8 – 124
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9 Diagnostics Functions and Online
Operation
Debugging
9.1
Debugging
The following sections describe the functions in the Debug menu, which allow to perform precise troubleshooting and error analysis on your progress.
GX IEC Developer Reference Manual 9 – 1
PLC diagnostics
9.2
9.2.1
Diagnostics Functions and Online Operation
PLC diagnostics
A CPU diagnostics
The status and the error codes of the CPU can be displayed. In the Debug menu select PLC
Diagnostics. The PLC will be checked and the dialogue below is opened.
� �
�
�
Fig. 9-1:
A CPU diagnostics
Item
�
�
�
�
Description
PLC Panel
Shows the operation status of the target PLC.
Monitor
The Start monitor button starts the communications with the PLC and the error display is updated.
The Stop monitor button stops the communication with the PLC and the error display.
Clicking on Error log or Clear Log automatically stops monitoring.
Error display (Present Error)
This section displays errors currently occurring in the connected CPU.
Error display (Error message)
This section lists the detected errors.
Click on the Error log button to display recent error messages from an error log.
The Clear Log button clears this error log.
Tab. 9-1:
A CPU diagnostics items
9 – 2
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.2.2
PLC diagnostics
QnA CPU diagnostics
The status and the error codes of the CPU can be displayed. In the Debug menu select PLC
Diagnostics. The PLC will be checked and the dialogue below is opened.
� �
�
�
Fig. 9-2:
QnA CPU diagnostics
�
Item
�
�
�
�
�
Description
PLC panel
Shows the PLC panel status of the target PLC.
PLC operation status
Shows the PLC operation status of the target PLC.
Monitor
The Start monitor button starts the communications with the PLC and the error display is updated.
The Stop monitor button stops the communication with the PLC and the error display. Clicking on
Error log or Clear Log automatically stops monitoring.
Swap module during run
Select the base number and the slot number for the module to be swapped and click on Detach
target.
Error display
Click on the Present Error button to display errors currently occurring in the connected CPU.
Click on the Error log button to display recent error messages from an error log. The Clear Log button clears this error log.
Tab. 9-2:
QnA CPU diagnostics items
GX IEC Developer Reference Manual 9 – 3
PLC diagnostics
NOTE
Diagnostics Functions and Online Operation
Double-click on a present/current error shown in the list to open the Error details dialogue.
The Error details dialogue shows the content of SD5 – SD15 (common error information) and SD16 – SD26 (individual error information).
Double-click
Fig. 9-3:
Double-click on error opens error details
Fig. 9-4:
Error details
9 – 4
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.2.3
PLC diagnostics
Q CPU/Q Remote I/O Module diagnostics
The status and the error codes of the CPU can be displayed. In the Debug menu select PLC
Diagnostics. The PLC will be checked and the dialogue below is opened.
� �
�
Fig. 9-5:
Q CPU diagnostics
�
Item
�
�
�
�
Description
PLC operation status
Shows the PLC operation status of the target PLC.
Monitor run/stop
The Start monitor button starts the communications with the PLC and the error display is updated.
The Stop monitor button stops the communication with the PLC and the error display. Clicking on
Error log or Clear Log automatically stops monitoring.
Error log
This section lists the detected errors.
Error status
This section shows whether the displayed error is a present error or an error from the error log.
Click on the Present Error button to display errors currently occurring in the connected CPU.
Click on the Error log button to display recent error messages from an error log. The Clear Log button clears this error log.
Tab. 9-3:
Q CPU diagnostics items
GX IEC Developer Reference Manual 9 – 5
PLC diagnostics
9.2.4
FX diagnostics
� � �
Diagnostics Functions and Online Operation
Fig. 9-6:
FX diagnostics
Item
�
�
�
Description
PLC panel
Shows the PLC panel status of the target PLC.
Error indication
Click on the Current Error button to display errors currently occurring in the connected CPU. The date and time values refer to the moment when the Current Error button was activated but not when the error occurred.
The currently occurring errors are listed including the error code and error message.
Monitor start/stop
The Start monitor button starts the communications with the PLC and the error display is updated.
The Stop monitor button stops the communication with the PLC and the error display.
Tab. 9-4:
FX diagnostics items
9 – 6
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.3
MELSECNET Diagnostics
MELSECNET Diagnostics
From a selectable target host station the status of a MELSECNET (II) or MELSECNET/10 network can be checked.
쐃 � � �
� �
Fig. 9-7:
Network diagnostics
�
Item
�
�
�
�
�
�
�
Description
Tabs for link modules
Select the tab for the link module for displaying the diagnostics results (AnN or AnA CPUs only support 2 modules).
Network information
Shows information on the network the selected target host station belongs to (for MELSECNET (II) the network number and group address are not displayed).
Link information
Shows the network status.
Monitoring
The Start monitor button starts monitoring. In RUN mode the display will be updated.
The Stop monitor button stops monitoring.
Communication information
Shows the communications status of the selected network (for MELSECNET/10 only the communications status is displayed).
Error History Monitor (see below)
Network Monitor Details (see below)
Other station information (see below)
Network diagnostics (see below)
Network test
Setup confirmation test
Station order check test
Communication test
Tab. 9-5:
Network diagnostics items
GX IEC Developer Reference Manual 9 – 7
MELSECNET Diagnostics Diagnostics Functions and Online Operation
NOTES
In a MELSECNET (II) network at maximum 2 link modules can be installed.
In a MELSECNET/10 network at maximum 4 link modules can be installed.
The network diagnostics check the network the connected host station belongs to. To change the network simply change the connection to the host station and select the connection to another host station.
For the connection to remote I/O modules the network diagnostics are not supported.
If the connection is established via a E71 unit the monitoring of an AnU CPU is performed like for an AnA CPU. MELSECNET (II) information can be monitored but no
MELSECNET/10 information.
Error history Monitor
This button in the Network diagnostics dialogue opens a dialogue that monitors and lists communication errors in an error history. Communication errors are listed separately for the forward and the reverse loop. Error history details can be monitored and the error history can be cleared.
Fig. 9-8:
Error history monitor
9 – 8
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation MELSECNET Diagnostics
Network Monitor Details
This button in the Network diagnostics dialogue opens a dialogue that displays network monitor details.
Fig. 9-9:
Network Monitor Details
GX IEC Developer Reference Manual 9 – 9
MELSECNET Diagnostics Diagnostics Functions and Online Operation
Other station information
This button in the Network diagnostics dialogue opens a dialogue that monitors other stations connected to the MELSECNET (II) or 10.
쎲 Network information: Shows information on the network of the selected target host station.
쎲 Other station information/Error information: If an error in a station, a stopped station, a reserved station, or a station with external power supply the error information field reads
ERR
. Click on the respective button to select an object for the error information to show detailed error information.
쎲 Display field for detailed error information: Shows the status of the relevant station for the selected item.
쎲 Start monitor: Starts monitoring.
쎲 Stop monitor: Stops monitoring.
Fig. 9-10:
Other station information
9 – 10
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation MELSECNET Diagnostics
The following information on other stations is available for the A series:
Information on each Station
1 Communications Status
2 Data Link Status
3 Parameter Status
4 CPU Operation Status
5 CPU RUN Status
6 Loop Status
7 Res. Station Designation
8 External Power Supply
9 Error Search Status
MELSECNET /10
MELSECNET /10 MELSECNET (II)
MELSECNET (II)
—
Master Station Master Local Control Station Normal Station
Loop Branch Loop Branch Loop Branch
앬
앬
앬
—
—
앬
앬
앬
앬
앬
앬
앬
앬
앬
—
앬
—
—
앬
앬
(—)
앬
앬
앬
앬
—
—
앬
앬
(—)
앬
앬
—
앬
—
—
앬
앬
앬
—
—
앬
앬
—
—
—
—
앬
—
—
앬
—
앬
앬
—
앬
앬
—
—
앬
앬
—
앬
—
—
앬
—
—
—
—
—
—
—
—
Tab. 9-6:
Information on other stations, A series
앬 = available, – = not available
The following information on other stations is available for the Q/QnA:
Information on each Station
1 Communications Status
2 Data Link Status
3 Parameter Status
4 CPU Operation Status
5 CPU RUN Status
6 Loop Status
7 Res, Station Designation
8 External Power Supply
9 Error Search Status
MELSECNET /10
MELSECNET /10 MELSECNET (II)
MELSECNET (II)
—
Control Station Normal Station Master Station Master Local
Loop Branch Loop Branch Loop Branch
앬
앬
앬
앬
앬
앬
앬
앬
—
앬
앬
앬
앬
앬
—
앬
(—)
—
앬
앬
(—)
앬
앬
앬
앬
앬
—
앬
앬
(—)
앬
앬
—
앬
(—)
—
앬
앬
앬
—
—
앬
앬
앬
—
앬
앬
앬
—
—
—
앬
(—)
—
—
앬
—
앬
—
앬
앬
—
—
앬
—
—
—
—
—
앬
—
—
—
—
Tab. 9-7:
Information on other stations, Q/QnA
앬 = available, – = not available
GX IEC Developer Reference Manual 9 – 11
MELSECNET Diagnostics Diagnostics Functions and Online Operation
Network diagnostics/Network test
This button in the Network diagnostics dialogue opens a dialogue where you can start or stop the link operation for the MELSECNET/10 host station, selected stations, or all stations.
The following items are available:
쎲 Network information: Shows information on the network of the selected target host station.
쎲 All stations operating status: Displays the operating status of the tested modules.
쎲 Link start/stop:
Link start: Stations that were stopped by the host station can be started. Stations that were stopped by another station can not be started.
Link stop: Stations can be stopped by the host station or another station.
Force link start: Stations can be started regardless of whether they have been stopped by a host station or another station.
However, the start can not be forced, if all stations were stopped. A start can not be forced neither, if for the link target another station is the target.
By monitoring SB and SW can be determined whether a forced start of a peripheral device can be performed. By monitoring SW0000 – SW0004 can be determined whether the execution was started or stopped by a host station.
A start can be forced, if the connection is established via C24, UC24, or QC24.
Via a MELSECNET (II) or 10 interface board the start can not be forced.
Via E71/QE71 the start can not be forced.
9 – 12
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation MELSECNET Diagnostics
NOTE
Network diagnostics/Setup confirmation test
This button in the Network diagnostics dialogue opens a dialogue where you can check the status of the station number, network address, and group address.
The following items are available:
쎲 Network information: Shows information on the network of the selected target host station.
쎲 Setting check test:
Parameter settings: All stations that are setup in the parameters except the reserved station are tested (If no network settings are setup, all stations are tested).
All stations: All stations are tested. No specified station is addressed.
Target module: The module by default selected for the for the line monitor is specified.
If no MELSECNET/10 module is connected, an error message is returned.
쎲 Execution results:
Station number: Shows the station number up to the specified station
(64 station numbers max.).
Loopback station: If the same loopback station was assigned to more than one station a “*” is displayed.
Network number: If the same network number was assigned to more than one station,
“*” is displayed.
Group number: Shows the group addresses of the stations for which the setup confirmation test is performed. For a remote I/O network faulty stations are indicated by a blank.
Reserved station: For stations specified as reserved stations “*” is displayed (if parameter confirmation was selected as test object).
Error: If a station is reserved in the parameter settings or if a module in all selected stations is faulty “*” is displayed.
Error network type (Q series only): Stations for which the parameter settings and current link do not match are indicated as “*”.
Double multiplex remote master station (Q series only): Stations with more than one sub master station within the same network are indicated by “*”.
Double parallel remote master stationXXX (Q series only): Stations with more than one sub master station within the same network are indicated by “*”.
The tests can not be performed for more than one station at one time.
During the test execution the scan execution is stopped.
GX IEC Developer Reference Manual 9 – 13
MELSECNET Diagnostics Diagnostics Functions and Online Operation
NOTE
Network diagnostics/Station order check test
This button in the Network diagnostics dialogue opens a dialogue where you can check the station order in the forward and reverse loops of a MELSECNET/10.
쎲 Network information: Shows the information on the network of the selected target host station.
The loop status is displayed for forward loops, reverse loops, forward/reverse loops, or loopback. The displayed total number of stations includes also the reserved-by station.
쎲 Loop test: All stations specified in the parameter settings except the reserved stations are tested (If no network settings were specified, all stations are tested).
All stations: All stations are tested. No specific station is addressed.
Target module: The module by default selected for the for the connection monitor is specified. If no MELSECNET/10 module is connected, an error message is returned.
쎲 Execution results: The station order is displayed in forward loop and reverse loop direction beginning from the host station.
For loopback only the station order in forward loop direction is displayed.
The tests can not be performed for more than one station at one time.
During the test execution the scan execution is stopped.
Network diagnostics/Communication test
This button in the Network diagnostics dialogue opens a dialogue that displays general communication test results.
9 – 14
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.4
Ethernet Diagnostics
Ethernet Diagnostics
The Ethernet diagnostics test several settings of the connected Ethernet modules.
For details on error messages and the buffer memory refer to the manuals of the corresponding modules:
쎲 Ethernet modules for the Q series (User's manual)
쎲 Ethernet modules for the QnA series (User's manual)
쎲 Ethernet modules AJ71E71-S3, A1SJ71E71-B2-S3, and A1SJ71E71-B5-S3
(User's Manual)
You can check the status of the following items:
쎲 Parameters
쎲 Errors
쎲 Individual connections
쎲 Individual protocols
쎲 LEDs
쎲 Received and sent e-mail information
GX IEC Developer Reference Manual 9 – 15
Ethernet Diagnostics
�
Diagnostics Functions and Online Operation
�
�
9 – 16
�
�
�
� � �
Fig. 9-11:
Ethernet diagnostics
Item
�
�
�
�
� �
Description
Target module setting
Here you select the Ethernet module to be checked. The Q series modules No. 1 – 4 can be selected.
A or QnA series modules are selected by their I/O address.
Change IP address display
Here the display of the IP address can be toggled between decimal or hexadecimal format.
Tabs for Ethernet information
Here different information types for the Ethernet modules are displayed.
PING test
Tests an Ethernet module that has completed its initialization or checks for any existing IP address.
The PING test can either be executed via an Ethernet board or via a direct connection to the PLC CPU.
Loop test
This function is intended for Ethernet modules that are compatible with the Q series function version B or higher. A loop instruction tests whether all modules under a specified network number or station number have completed their initialization.
If this test is executed for Ethernet modules that are compatible with the Q series function version
A the response can not be evaluated and is processed as not responding.
The loop test can either be executed via an Ethernet board or via a direct connection to the PLC
CPU.
COM. ERR. off
Turns off the communications error LED.
Start monitor
Starts the Ethernet diagnostics.
Tab. 9-8:
Ethernet diagnostics items
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation CC-Link(-LT) Diagnostics
9.5
NOTE
CC-Link(-LT) Diagnostics
The CC-Link(-LT) diagnostics monitor the network information of each station and test the network status.
The CC-Link(-LT) diagnostics can be started via the PLC CPU independently from the
CC-Link station running as master, stand-by master, or local station.
For the diagnostics via a Q CPU in Q mode the module QJ61BT11 is required.
For the diagnostics via a Q CPU in A mode the module AJ61BT11 or A1SJ61BT11 is required. If a program for the A series includes refresh parameters, the network test is disabled.
Monitoring a CC-Link line (host station)
The CC-Link(-LT) diagnostics monitor the CC-Link line connected to the PLC CPU via the host station.
�
�
�
�
� �
Fig. 9-12:
CC-Link(-LT) Diagnostics
�
GX IEC Developer Reference Manual 9 – 17
CC-Link(-LT) Diagnostics Diagnostics Functions and Online Operation
Item
�
�
�
�
�
�
�
Description
Line Monitor (Host station)
Lists all connection relevant CC-Link information.
For details on the indication of special relays (SB) and special registers (SW) refer to:
Loop test: See section below
Monitoring other station: See section below
Module setting (Q series only):
Specify the module the CC-Link diagnostics have to be executed for. Before executing make sure that your Q CPU and QJ61BT11 are of function version B or higher.
Network test
The data link is started or stopped for the specified CC-Link module.
Monitor start/stop
The monitoring of the host station is started or stopped.
Acquire the setting information
The setting information of the CC-Link module is acquired for the CC-Link status.
After execution the acquired setting information can be set as EEPROM parameters by turning ON the device YnA via the Device Test.
Loop test: See section below
Monitoring other station: See section below
Tab. 9-9:
CC-Link(-LT) Diagnostics items
9 – 18
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation CC-Link(-LT) Diagnostics
Monitoring other station
The CC-Link(-LT) diagnostics monitor the CC-Link line connected to the PLC CPU via other stations.
�
�
Fig. 9-13:
Line monitor (Other station)
Item
�
�
Description
Information on other station
Acquires and displays information on reserve stations, settings for invalid errors, station types, and occupied station numbers from the Q CPU.
Invalid station if temporary error
Modules that have been replaced without corresponding remote station are detected in online operation mode.
Tab. 9-10: Line monitor (Other station) items
Maker Code
Displays the manufacturer's name and identification of the modules connected via CC-Link.
The manufacturer identification is also displayed, in case the manufacturer name has not been entered.
The remote I/O modules are represented as blank entry because they do not provide a manufacturer name or identification.
The list of manufacturers is saved as file (PARTNER.DAT) in the GX IEC Developer installation directory. It can be edited with a text (ASCII) editor.
When editing the list the following formatting must be kept:
Description
Maximum number of characters
Allowed characters
햲
Remarks
Maker Code
5
0 – 9
Manufacturer identification not consisting of 5 digits is ignored.
Company name
255
Alphanumeric, symbols
Display varies depending on screen size.
More than 75 characters can not be displayed in one window.
Tab. 9-11: PARTNER.DAT formatting
햲
The maker's name should be completely entered in " ". Example: "##### Co., Ltd."
GX IEC Developer Reference Manual 9 – 19
CC-Link(-LT) Diagnostics Diagnostics Functions and Online Operation
Loop test
The loop test tests all stations or a selected station.
Fig. 9-14:
Loop test
�
�
Item
�
�
Description
Monitor all stations
Monitors all CC-Link stations
Illegal stations are indicated in red.
Loop test
Specify whether to test All stations or a Selected station. Click Execute Test to execute the loop test.
Tab. 9-12: Loop test items
9 – 20
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.6
System Monitor
System Monitor
The System Monitor displays comprehensive information on the entire connected PLC system. The System Monitor supports Q series PLCs only.
In the Debug menu select System Monitor to open the following dialogue:
Fig. 9-15:
Mode: System Monitor
Installed status
This section illustrates the selected base and shows the installed modules and vacant slots
(”not mounted”).
Base
This section lists the connected bases and displays the error status coded by colors (see section
“Status”). If several bases are connected, the base to be displayed can be selected via radio buttons.
Parameter status
This section gives additional information on the installed modules and their addresses.
Status
Indicates the color codes for the status displayed in the “Base” section.
GX IEC Developer Reference Manual 9 – 21
System Monitor Diagnostics Functions and Online Operation
Start monitor/Stop monitor
Starts or stops monitoring.
Diagnostics
Also available in the context menu as Diagnosis feature execution.
Opens appropriate diagnostics functions for the selected module:
쎲 For a CPU module the PLC diagnostics dialogue (see section 9.2) is opened.
쎲 For an Intelligent Function Module the Intelligent Function Module Utility (see section
쎲 For network modules the Networks Diagnostics dialogue (see section 9.3) is opened.
Module’s Detailed Information
Also available in the context menu as module’s detailed information or via double-click on a module.
Opens the following dialogue that displays detailed information on the selected module.
Fig. 9-16:
Module’s Detailed
Information
NOTE
It may take a few seconds until all details are displayed, especially those for the error display.
Error History: Displays the stored error history.
H/W Information: Opens a dialogue that displays more details on the LED and SW status.
Start monitor: Starts monitoring.
Stop monitor: Stops monitoring
9 – 22
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
Base Information
Opens the following dialogue that displays information on the selected base.
Fig. 9-17:
Base Information
System Monitor
Product Inf. List
Opens the Product Information List that gives an overview of the connected PLC system.
The Product Information List can be exported into a CSV file (comma separated value) via the CSV file creating button. The CSV format can be imported by many other applications.
Fig. 9-18:
Product Information List
GX IEC Developer Reference Manual 9 – 23
CC-Link IE Controller Network Diagnostics Diagnostics Functions and Online Operation
9.7
NOTE
CC-Link IE Controller Network Diagnostics
The CC-Link IE Controller Networ k is suppor ted only by Qn(H)-ser ies and
QnU(D)(E)(H)-series PLCs.
The CC-Link IE Controller Network diagnostics monitor the network status and the operating status of each station can be checked.
햲 Select the menu Diagnostics - CC IE Control diagnostics.
햳 When two or more CC-Link IE controller network modules are mounted, the dialog box
Select diagnostics destination appears. Select a network to be diagnosed and click
OK.
Fig. 9-19:
Select diagnostics destination
햴 The dialog box CC IE Control Network Diagnostics is displayed. For its operation, refer to the following explanation.
9 – 24
Fig. 9-20:
CC IE Control Network Diagnostics
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation CC-Link IE Controller Network Diagnostics
Change Module: When two or more CC-Link IE controller network modules are mounted,
Select diagnostics destination is displayed by clicking the button Change Module.
Select station: Specifies station No. of selected station.
Change select station: Enter a station No. to Select station and click Change select station to change the selected station.
Network information display: See section 9.7.1
Select station network device status display: See section 9.7.2
Button Communication test
햲
,
햳
: This button in the CC IE Control Network Diagnostics dialogue opens a dialogue that displays general communication test results.
Button Link start/stop
햲
,
햳
: Receiving data from other stations and sending data of its own station can be disabled in a case such as debugging. (Transient transmission is not stopped.)
Each station's cyclic transmission can be stopped or restarted from GX IEC Developer.
Note that this function is not available in circuit test mode.
Button Logging
햲
,
햳
: See section 9.7.3
Button System monitor: See section 9.7.4
Button Remote operation: See section 9.7.5
햲
Selectable when the selected station is connected to GX IEC Developer (the own station).
Not selectable when it is any other station.
햳
Not selectable in circuit test mode.
GX IEC Developer Reference Manual 9 – 25
CC-Link IE Controller Network Diagnostics
9.7.1
Network information display
Diagnostics Functions and Online Operation
The result of checking the line status and parameter setting status is displayed.
9 – 26
Fig. 9-21:
Network information display
Module
o: Displays the module No. of network which is being diagnosed.
Network No.: Displays the network No. of network which is being diagnosed.
Total No. of stations: Displays the total number of stations in a network.
I/O master station: Displays the station No. of I/O master station.
Link scan time: Displays the current link scan time.
Icon: Displays the status of each station and status between stations.
Button Prev: When the total number of stations is 61 or more, the screen prior to network information display is displayed by clicking Prev.
Button Next: When the total number of stations is 61 or more, the screen next to network information display is displayed by clicking Next.
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation CC-Link IE Controller Network Diagnostics
Description of icons
The status of each station and status between stations are displayed.
� � � �
Fig. 9-22:
Different icons
쐃 Station No.
1 to 120: Displays the station No. of the CC-Link IE controller network module.
Undef.: Displayed for the station for which parameters have not been set
햲 or station No. is not assigned.
햲
For display of the station for which parameters have not been set, there are restrictions on the CC-Link IE controller network module versions. Check the serial No. and software version for applicability.
쐇 Connected
This is displayed for the station connected to GX IEC Developer (own station).
쐋 Icon
When double-clicking the station icon, System Monitor is displayed, see section 9.1.5.
The icons that may be displayed are listed below.
GX IEC Developer Reference Manual 9 – 27
CC-Link IE Controller Network Diagnostics Diagnostics Functions and Online Operation
Icon Description
Normally operating station
Faulty station (a fault has occurred on a module, board, display, or cable while cyclic transmission is performed.)
Faulty station (Cyclic transmission is stopped.)
Station in a different shared group (no cyclic data are received.)
Disconnected station (black)
Reserved station (gray)
NOTE
쎲
쎲
Selected station (station icon edged with green)
쎲
This can be selected by clicking a station icon or moving a focus and holding down a space bar.
The detailed information is displayed at [Select station network device status display].
In addition, disconnected station and reserved station cannot be selected.
Focusing (station icon edged with dotted line)
쎲
쎲
Holding down a space bar makes a station to be selected station.
In addition, disconnected station and reserved station cannot be selected.
Communication error
쎲
When selecting the station next to the one where communication error is occurring, the detailed information is displayed at Select station network device status display.
Tab. 9-13: Description of icons
쐏 Present Control and Assign Control
Present Control: Displayed to the station actually operating as control station.
Assign Control: Displayed to the station set by network parameters.
When multiple stations on the same system (in a multiple CPU system configuration) have the same network No. If a station other than those on the system is selected while a station of the lowest start I/O No. has a baton pass error, a transient execution error (no baton passing on the own station) (E504H) will occur. Resolve the baton pass error, and then redo the operation.
9 – 28
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation CC-Link IE Controller Network Diagnostics
Display position of a disconnected station
There are two cases for positioning a disconnected station on the screen.
햲 When normal connection information has been obtained
햲
,
햳
The disconnected station (station No.4) is displayed in the position where it was connected when normal.
Fig. 9-23:
When normal connection information has been obtained
햳 When normal connection information has not been obtained
The disconnected station (station No.4) is displayed on the IN side of the GX IEC
Developer connected station.
NOTES
Fig. 9-24:
When normal connection information has not been obtained
햲
The normal connection information is network configuration data that the CC-Link IE controller network module on the GX IEC Developer connected station stores in its memory when all stations are normal. When all of the following conditions are met, the normal connection information can be obtained. Also, after any of the conditions became unsatisfied, if all of them are met again, the normal connection information will be updated.
- All stations are in data link status (Cyclic transmission status of each station (SB00B0) is OFF.)
- No loopback station (Loopback status (SB0065) is OFF.)
- No station has a parameter error. (Parameter status of each station (SB00E0) is OFF.)
- The number of actually connected stations is the same as the total of stations that is set for the control station (except reserved stations).
햳
For obtaining the normal connection information, there are restrictions on the version of the
CC-Link IE controller network module on the GX IEC Developer connected station. Check the serial No. and software version for applicability.
If the system was rewired after system activation, set Normal connection information refresh instruction (SB000C) to ON to update the normal connection information.
If station No. of a disconnected station (No.4) is set to an invalid value (station No.9) by mistake after acquisition of the normal connection information, the icon of the station will be displayed on the IN side of the GX IEC Developer connected station.
Fig. 9-25:
Display example
GX IEC Developer Reference Manual 9 – 29
CC-Link IE Controller Network Diagnostics
9.7.2
Diagnostics Functions and Online Operation
Select station network device status display
The detailed information of the selected station is displayed. A module is selected here. For selection of a board or terminal display, refer to the relevant manual.
9 – 30
Fig. 9-26:
Select station network device status display
Description of select station network device status display:
Item
Group No.
Shared group No.
Description
Displays a group number of the selected station.
Displays a shared group number of the selected station.
Mode
Displays the mode of the selected station.
Display content
0 to 32
0 to 120
Online
Offline
H/W test
Self-loopback test
Circuit test
Test between station
Operating status
Normal operation
Operation error (data link continued) (yellow)
Operation error (data link discontinued) (red)
Select station network device status display
See section Indicator LEDs in the
Hardware Manual of the relevant
CPU modul.
Data linking
Cable disconnection
Communication status
Error details button
Communication error (other than cable disconnection)
Module error (CC-Link IE controller network parameter setting error or transient transmission error)
Displayed at faulty parts.
See section "Error details".
Tab. 9-14: Description of select station network device status display
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
NOTES
CC-Link IE Controller Network Diagnostics
When a transient transmission error occurs, check the error description in error code and take corrective action.
When a transient transmission error log is cleared after taking a corrective action toward the error, the communication error display is cleared.
See section 9.7.3.
When multiple stations on the same system (in a multiple CPU system configuration) have the same network No.
If a station other than those on the system is selected while a station of the lowest start I/O
No. has a baton pass error, a transient execution error (no baton passing on the own station)
(E504H) will occur.
Resolve the baton pass error, and then redo the operation.
Error details
When clicking on the error showing button the dialog box Error details is displayed.
Take corrective action according to troubleshooting.
Fig. 9-27:
Error details
GX IEC Developer Reference Manual 9 – 31
CC-Link IE Controller Network Diagnostics
9.7.3
Diagnostics Functions and Online Operation
Logging
The history for the communication path switching and transient transmission error can be monitored and the error information can be cleared.
Note that these operations are not available in circuit test mode.
햲 The dialog box Logging is displayed by clicking on the button Logging in the dialogue box CC IE Control Network Diagnostics. For its operation, refer to the following explanation.
Fig. 9-28:
Tab Monitor detail
9 – 32
Fig. 9-29:
Tab Error clear
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation CC-Link IE Controller Network Diagnostics
Display Station: Displays the network No., group No., and station No. of the connected station.
Tab Monitor detail: The history for the communication path switching and transient transmission error is displayed.
Switch transmission path
햲
Loop Status: Displays the status of a loop.
Loopback station: Displays a station where loopback occurs at IN-side and OUT-side at loopback.
Date: Displays a time when a communication path is switched.
Transient transmission error
햲
Error Code: Displays error codes. For details concerning the error codes please see the
CC-Link IE Controller Network Reference Manual, section 10.2 Error Code List.
Target Net: Displays network No. of the station where an error was detected.
Target Station: Displays station No. of the station where an error was detected.
Date
햳
: Displays a time when a transient transmission error is detected.
Button Save error log: Saves the description of monitor detail in CSV file. You have to specify the drive/path and the file name for saving the CSV file.
Tab Error clear: The error information is cleared.
To clear error information select an item at Clear type. The error information then can be cleared by clicking the button Clear Error info.
햲
Up to 100 logs are displayed, and when the maximum is reached, they will be erased in sequence from the oldest one.
Note that when the screen is closed, logs numbered 17 or higher are deleted. To retain them, click on the Save error log.
햳
If a transient transmission error is detected during start-up of the CC-Link IE controller network module, the time of the error may be displayed as blank.
GX IEC Developer Reference Manual 9 – 33
CC-Link IE Controller Network Diagnostics
9.7.4
Diagnostics Functions and Online Operation
System monitor
The module status of the CC-Link IE controller network module can be checked.
햲 Perform any one of the following operations.
– Click in the CC IE Control Network Diagnostics dialog box.
– Double-click in the CC IE Control Network Diagnostics dialog box.
– Select Diagnostics - System Monitor menu.
햳 The System Monitor dialog box is displayed.
햴 Perform any one of the following operations.
– Click in the System Monitor dialog box.
– Double-click Installed status of the CC-Link IE controller network module in the
System Monitor dialog box.
햵 The Module's Detailed Information dialog box is displayed.
For its operation, refer to the following explanation.
9 – 34
Fig. 9-30:
Module's Detailed Information
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation CC-Link IE Controller Network Diagnostics
Module
Module Name: Displays the name of a module.
I/O Address: Displays the start I/O number of a module.
Implementation Position: Displays the slot position where a module is mounted.
Product information: Displays product information.
- The end of the product information indicates function version of the module.
- When the end is "B", it indicates the module of function version B.
Module Information
Module access: Displays Possible when no watchdog timer error occurs.
Status of I/O Address Verify: The parameter setting and the verification result of the mounted module are displayed.
Error Display
Present Error: Displays the latest error code. For details concerning the error codes please see the CC-Link IE Controller Network Reference Manual, section 10.2 Error Code List.
Button Error History: The history of error codes is displayed by clicking the button Error
History. For details concerning the error codes please see the CC-Link IE Controller Network
Reference Manual, section 10.2 Error Code List.
Error contents - Disposal: The description and corrective action of an error code selected by
Error Display.
Button H/W Information: The LED information and switch information of the module can be checked.
Fig. 9-31:
H/W Information
GX IEC Developer Reference Manual 9 – 35
CC-Link IE Controller Network Diagnostics Diagnostics Functions and Online Operation
Item
RUN
PLC
ONLINE
TEST
OFFLINE
M/S. ERR.
PARAM.ERR.
F LOOP ERR.
MANAGER
SUB MANAGER
NORMAL
TOKEN PASS
DATA LINK
R LOOP ERR.
EXT. POWER
Description
Displays the operating status of a module.
0001: Operating normally
0000: Hardware fault or watchdog timer error
Displays the network type.
0001: Controller network
Displays the operation mode of the CC-Link IE controller network module.
0001: Online mode
0000: Other than online mode
Displays the operation mode of the CC-Link IE controller network module.
0001: Test mode
0000: Other than test mode
Displays the operation mode of the CC-Link IE controller network module.
0001: Offline mode
0000: Other than offline mode
Displays the detection status of duplicated control station or station No.
Check the network status by CC IE Control Network Diagnostics.
0001: Duplicated control station or station No. detected
0000: Undetected
Displays the parameter error detection status.
Check the network status by CC IE Control Network Diagnostics.
0001: Parameter error detected
0000: Undetected
Displays the IN-side error detection of the CC-Link IE controller network module.
Check the network status by CC IE Control Network Diagnostics.
0001: IN-side error detected
0000: Undetected
Displays the station type of the CC-Link IE controller network module.
0001: Control station is operating
0000: Other than control station is operating
Displays the station type of the CC-Link IE controller network module.
0001: Sub-control station is operating
0000: Other than sub-control station is operating
Displays the station type of the CC-Link IE controller network module.
0001: Normal station is operating
0000: Other than normal station is operating
Displays the baton pass status of the CC-Link IE controller network module.
0001: Baton pass being executed
0000: Baton pass unexecuted
Displays the data link status of the CC-Link IE controller network module.
0001: Data link being executed
0000: Data link not executed
Displays the OUT-side error detection of the CC-Link IE controller network module.
Check the network status by CC IE Control Network Diagnostics.
0001: OUT-side error detected
0000: Undetected
Displays the external power supply status, of the CC-Link IE controller network module with external power supply function.
0001: External power supplied
0000: No external power supplied
Tab. 9-15: H/W LED Information
9 – 36
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
Item
NET WORK NO.
GROUP NO.
STATION NO.
MODE
CC-Link IE Controller Network Diagnostics
Description
Displays the network No. of the CC-Link IE controller network module.
(Range: 1 to 239)
Displays the group No. of the CC-Link IE controller network module.
(Range: 1 to 32)
Displays the station No. of the CC-Link IE controller network module.
(Range: 1 to 120)
Displays the operation mode of the CC-Link IE controller network module.
0: Online
2: Offline
5: Station-to-station test
6: Circuit test
7: Self-loopback test
9: Hardware test
Displays the configuration of the CC-Link IE controller network module.
CONFIG.
Tab. 9-16: H/W SW Information
GX IEC Developer Reference Manual 9 – 37
CC-Link IE Controller Network Diagnostics
9.7.5
Diagnostics Functions and Online Operation
Remote Operation
The operating status of the CPU module that is connected to a network can be changed.
햲 Perform any one of the following operations.
– Click the button Remote operation in the CC IE Control Network Diagnostics dialog box.
– Select On line - Remote operation menu.
햳 The Remote operation dialog box is displayed.
햴 Set the following item and click the button Execute.
9 – 38
Fig. 9-32:
Remote operation
Connection target information: The connection target information is displayed.
Operation: Select the radio button PLC to select the operating status to be changed.
Operation during RUN, STEP-RUN: Select the operation of the device memory and signal flow at RUN or STEP-RUN.
Specify execution destination: Set the target of executing Remote operation.
– Currently specified station: Remote operation is executed to the station which is specified as connection target.
– All stations: Remote operation is executed to all stations in the network specified by Specify execution unit.
– Specific group: Remote operation is executed to the specified group No. in the network specified by Specify execution unit.
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.8
Online Module Change
Online Module Change
The System Monitor display also provides the option of online module change (hot swapping) with the QnPH, QnPRH and Q Remote I/O PLCs.
In the Debug menu select Online Module Change to open the following dialogue or select the different mode, if it was opened via System Monitor already:
Fig. 9-33:
Mode: Online module change
GX IEC Developer Reference Manual 9 – 39
Online Module Change Diagnostics Functions and Online Operation
The following explains a sequence of operations for making online module change from
System monitor.
햲 Choose the module you want to change from Mounting status on the System monitor screen. (Module selection waiting status)
햳 After the Online module change dialogue box has appeared, click the Execution button. (Online module change execution confirmation)
Fig. 9-34:
Online module change – execution confirmation
NOTE
Depending on the faulty condition of the module to be changed, the type of the module may not be acquired. In that case, "Unknown" appears in the Target module name display field.
햴 The dialogue box indicating that online module change can be made appears. (Online module change completion confirmation)
Fig. 9-35:
Online module change – completion confirmation
9 – 40
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation Online Module Change
햵 After changing the module, click the Execution button.
햶 If online module change is completed properly, the following dialogue box appears.
(Module control resumption confirmation)
Fig. 9-36:
Online module change – resumption confirmation
If it is not completed properly, the following dialogue box appears.
Fig. 9-37:
Online module change – error
Click the OK button. As clicking that button the Online module change dialogue box is displayed again, and you can restart the procedure from step
햳.
GX IEC Developer Reference Manual 9 – 41
Online Module Change
NOTES
Diagnostics Functions and Online Operation
GX IEC Developer cannot perform the online module change of multiple modules simultaneously.
Note that if the Process CPU/redundant CPU is in either of the following statuses, online module change cannot be performed.
앫 PLC CPU's RESET/L.CLR is reset.
앫 PLC CPU is stopped due to stop error.
If online module change is performed from two personal computers to one PLC CPU, an error message appears on the personal computer where online module change was performed later.
If the PLC CPU is reset or powered off while the Online module change execution dialogue box is being displayed, online module change cannot be continued and an error message appears.
9 – 42
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.9
9.9.1
PLC System Error Check
PLC System Error Check
System errors
If a system error occurs, GX IEC Developer automatically outputs the corresponding error code in the System Errors dialogue.
The System Errors dialogue can be opened by Debug System errors.
Fig. 9-38:
System Errors dialogue
Fig. 9-39:
System Errors dialogue for QnPRH
NOTES
The button Show opens the editor window containing the error location of the selected error if it is possible to show it. You can obtain additional information on the error message by selecting the Help button
.
A system error can be cleared by selecting the button Clear.
Clearing the system error is only possible for errors that allow the PLC to continue operation.
If the cause of the error is still present, it will be re-registered in the failure history.
The Clear error functionality is available for all Q and QnA series PLCs only.
GX IEC Developer Reference Manual 9 – 43
PLC System Error Check
9.9.2
Diagnostics Functions and Online Operation
User-defined errors
These functions are not available for the FX series.
Error flags combined with an error location program make it possible to display errors that occur in the course of the process. If an error is encountered, an error flag (F) is set, together with a special relay (M/SM) to indicate the presence of an error condition. The error flags F0 –
F127 can be programmed for example in the MELSEC network with the OUT function.
The text for the error messages must be stored in the error file USER_ERR.TXT in the current project’s directory.
How to create an error messages file
햲 Open the Windows Notepad editor (you can also use any other editor that saves files in
ASCII format without formatting codes).
햳 Create a new file.
햴 Enter the error messages, one message per line.
Syntax:
0, Text1
1, Text2
…
You must enter a space between the comma and the text of the error message.
Meaning:
In the example above Text1 will be displayed, if F0is set and Text2 is displayed, if F1 is set.
햵 Store the file as USER_ERR.TXT in the current project’s directory.
9 – 44
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation PLC System Error Check
9.9.3
NOTE
9.9.4
Hardware Diagnostics
Selecting HW Diagnosis in the Debug menu shows all hardware errors registered
(not available for FX series).
M9000 (A) / SM60 (Q/QnA): Fuse blown. This relay is set as soon as a blown fuse is registered in one or more modules in the system. The relay will remain set even after you switch back to normal status. (Does not apply for A2C CPUs.)
M9002 (A) / SM61 (Q/QnA): I/O module verify error.
M9005 (A) / SM53 (Q/QnA): Mains power drop. The relay is set after a power drop of no more than 20 ms. You can reset the relay after switching the power supply off and on again.
M9006 (A) / SM52 (Q/QnA): Battery low. The voltage of the retentive memory battery has dropped below the minimum level. This flag is reset when the battery is replaced.
M9007 (A) / SM51 (Q/QnA): Battery low (latch relay). The voltage of the retentive memory battery has dropped below the minimum level. This flag is reset when the battery is replaced.
M9026 (A) / SM211 (Q/QnA): Clock data error. Set in the event of incorrect clock data (registers D9025 – D9028). (Only for AnN/AnS CPUs.)
Hardware errors are indicated by cross symbols instead of minus signs on the corresponding buttons. Clicking on a button with a cross displays context-sensitive help for that error.
You will find detailed descriptions and information on special relays and special registers in the controller manuals.
Scan
The Scan command in the Debug menu provides a statistical display of the scan time performance of the program in the PLC CPU.
The program execution cycle periods can vary depending on status conditions, e.g. whether inputs are polled during the cycle or not. The PLC CPU logs the following scan times:
Actual Scan Time: The current program cycle time (special register D9018 in the A series;
D8010 in the FX series)
Minimal Scan Time: The last minimum scan time saved (special register D9017 in the A series; D8011 in the FX series)
Maximal Scan Time: The last maximum scan time saved (special register D9019 in the A series; D8012 in the FX series)
GX IEC Developer Reference Manual 9 – 45
PLC System Error Check
9.9.5
Diagnostics Functions and Online Operation
Show Step
To show the location of a given PLC Main program step in the source code you use the Show
Step command in the Debug menu.
When you call the menu command Debug Show Step, a dialog will be displayed to enter the step number. The maximum number of characters in the Step number edit box of the
Show Step dialogue is limited to the number of characters in the highest step number of the current main program. E.g. if the main program has 7490 steps, then the edit box is limited to a maximum of 4 characters.
After pressing Show, the body where the selected step is located will be opened, and the line or object corresponding to that step will be marked.
9 – 46
Fig. 9-40:
Menu command Debug
Show Step
If the selected step number is valid, the location of the step will be marked:
Fig. 9-41:
The desired step is marked and displayed
If the selected step number is invalid, the following error message is shown:
Fig. 9-42:
Error message
In the message the actual step range of the program is shown.
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation PLC System Error Check
If the selected step number is valid, but the code does not belong to any of the editors, the following message is displayed:
Fig. 9-43:
Message
NOTES
This command is available, if a compiled project is open. It is disabled for Remote I/O projects.
This functionality can only show steps of the Main program. Showing step locations in the
Sub and SFC programs is not supported.
Since the SFC POUs of FX series projects are compiled into the Main program, it is possible that a step of a FX-series Main program is located in a SFC body. If you specify a step that originates from a SFC POU, the appropriate body will be opened, but no source code position will be marked.
GX IEC Developer Reference Manual 9 – 47
The Device Editor
9.10
Diagnostics Functions and Online Operation
The Device Editor
The device editor is a tool for displaying and editing the contents of the PLC CPU’s word and bit devices. The main element of the device editor is a table that is very similar to a Microsoft Excel worksheet, both in its appearance and in the way it is used.
You can read the values from the CPU to the table, and after editing them you can then write the new values back to the CPU. Additionally, you can also write the table contents to an external file and load external files for editing. These files are stored in Excel 4.0 format, which makes it possible to edit them with Microsoft’s Excel spreadsheet program as well.
Maximum table size is 16,383 lines and 255 columns, which means it can handle a total of
4,177,665 cells. Effectively, the number of bit and word devices you can load to the table is only restricted by the amount of available memory on your computer.
Warning prompts are displayed before all operations that alter table ranges, before critical operations (e.g. writing to CPU inputs) and before you close the device editor.
9 – 48
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.10.1
The Device Editor
The worksheet
The Device Editor option in the Debug menu opens the Device Edit window, which contains the worksheet table in which all editing actions are performed.
쐇
쐃
쐋
쐏
쐄
쐂
Fig. 9-44:
Device editor
Item
�
�
�
�
�
�
Description
The numbers of the devices following the first device are obtained by adding the values shown at the heads of the column.
The leftmost column of the table contains the first of a consecutive sequence of devices.
Each series of devices is displayed across a table line.
The values of the devices are contained in the individual table cells.
The current display mode of the selected cell is shown underlined. The display mode is set in the pop-up menu (see below).
Commands can be accessed by clicking on the buttons (see below)or with the pop-up menu (see below).
Tab. 9-17: Device editor items
GX IEC Developer Reference Manual 9 – 49
The Device Editor
9.10.2
Diagnostics Functions and Online Operation
Buttons
Read from PLC: Reads the values of word and bit devices (registers) from the PLC. You can choose to read either the entire table or a selected table range.
Write to PLC: Writes the table values to the PLC’s word and bit devices (registers). You can write either the entire table or a selected table range.
Fig. 9-45:
Selected Devices: Read/write only the devices selected in the table.
All Devices: Read/write all the registers in the table.
Fig. 9-46:
For QnPRH:
Selected Devices: Read/write only the devices selected in the table.
All Devices: Read/write all the registers in the table.
Read from File: Loads an external file stored in Excel 4.0 format.
Write to File: Writes the GX IEC Developer device table data to an external file in Excel 4.0
format.
E
WARNING:
The device table settings are
not
stored with the GX IEC Developer project. They are lost irrevocably when you close the
Device Edit
window. If you want to access the data again later you should always save the table to a file before closing the edit window.
9.10.3
The pop-up menu
To display the pop-up menu click with the right mouse button or press
¨
.
Fig. 9-47:
Device editor pop-up menu
9 – 50
Cut: Copies the contents of selected cells to the clipboard and deletes them from the table
(§x)
Copy: Copies the contents of selected cells to the clipboard
(§C)
Paste: Pastes the content of the clipboard to the table
(§V)
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Device Editor
Paste Text: Opens a dialogue box in which you can enter ASCII text to paste to the table.
ASCII characters are only displayed in the table in the ASC display mode. You cannot enter more characters than the selected device can store. A data register can only store two ASCII characters, for example. You can enter more characters by selecting several cells (i.e. a series of registers) and entering ASCII text.
Insert Devices: Displays this dialogue box:
Fig. 9-48:
Device
: List of the available devices for selection.
All
: Selects the entire range of devices for insertion in the table.
Addresses: Allows specification of a specific address range.
Display Mode
: Specifies the display mode for the new registers
Delete Devices: Deletes the selected device or device range. A prompt is displayed asking for confirmation before the delete operation is executed.
Find Device: Searches for specific devices. You can select the search direction.
Find Value: You can also search for a specific value in a device register. Again, you can specify the search direction.
Replace Value: Search and replace function for replacing device register values.
Display Mode: Displays this dialogue box:
Fig. 9-49:
Display Mode:
Mode for displaying the selected devices
Register
: Selects 16 or 32 bit register display.
Options: Displays the following dialogue box in which you can set the basic options for the table structure:
Fig. 9-50:
Device editor options
Number of Columns
Automatic: 8 rows for octal registers, 10 rows for decimal registers, 16 rows for hex registers
Input Number: You can enter a value between 1 an 255.
GX IEC Developer Reference Manual 9 – 51
The Device Editor Diagnostics Functions and Online Operation
Number of Rows
Maximum Number (16383): Sets the rows to the maximum of 16,383 rows.
Input Number: You can enter a value between 1 and 16,383.
Use Colors: When this check box is selected the table is displayed using different colors.
Additional Safety Inquiry: When this check box is selected the system displays an additional prompt asking for confirmation for some critical operations.
Inserting devices with the Insert Devices dialogue box
Open the Device Edit window and select the top left cell of the table.
햲 Click with the right mouse button to open the pop-up menu.
햳 Click on Insert Devices with the left mouse button to display the Insert Devices dialogue box.
햴 Select the device type, address range and display mode, then click on OK.
Fig. 9-51:
Data registers D
Address range: D12 – D16
Display mode: Decimal
The devices are inserted in the table. Initially, all the devices are given a default value of 0.
Fig. 9-52:
Devices D12 – D16 have been inserted in the table.
D12 D13 D14 D15 D16
NOTE
Inserting devices directly
Open the Device Edit window.
햲 Click in any cell in a free line. All the cells in the line must be empty!
햳 Enter the device. The system automatically switches to editing mode when you make an entry. GX IEC Developer only accepts valid entries. If you make an incorrect entry editing mode will remain active.
The inserted device is then displayed in the leftmost table column.
When you enter registers directly you can only store one register in a line; the remaining cells in the line are disabled and cannot be selected.
9 – 52
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Device Editor
NOTE
NOTE
Entering device values
햲 Select the cell where you want to enter the value.
햳 Enter the new value. The system switches to editing mode automatically when you make an entry. GX IEC Developer only accepts valid entries. If you make an incorrect entry editing mode will remain active.
Double-clicking on a bit device (or pressing
´) toggles the value of the device between 0 and 1. Double-clicking on a word device activates editing mode.
Entering 32-bit values
A 32-bit value is stored in two 16-bit registers.
햲 Select the first of the two table cells.
햳 Hold down the ¨ key and extend the selection to include the second cell using the mouse or cursor key. Both cells now have a bold outline and the second cell is shaded.
햴 Press §m to select the Display Mode dialogue box from the pop-up menu.
햵 Select the 32-bit option in the Registers field.
햶 Click on OK to link the two selected cells.
햷 Enter a 32-bit value in the cell. GX IEC Developer will only accept valid entries.
You can use the standard Windows mouse actions and key combinations in the device table.
Special key combinations are listed in the Appendix B of this manual.
GX IEC Developer Reference Manual 9 – 53
The Device Editor
9.10.4
Editing tables in Microsoft Excel
Diagnostics Functions and Online Operation
Fig. 9-53:
Entries in Excel
D12 – D16
X5 – X9
Changing device designations
햲 Overwrite the entry in D12 in leftmost column, e.g. by entering D24.
The line now contains the five data registers D24 – D28.
Adding devices to a line
햲 Select the cell in column +5 and enter the value to be contained by the new register
D17.
햳 Click with the right mouse button to open the pop-up menu and select the Number
Format option.
햴 Select the appropriate number format from the list in the dialogue box.
The number formats in Excel correspond to the display mode in GX IEC Developer.
These formats are represented by a fixed number of spaces and the @ character:
Fig. 9-54:
BIN: 1 space
HEX: 2 spaces
ASC: 3 spaces
DEC: No spaces
OCT: 4 spaces
NOTE
Setting the correct number format (i.e. the right display mode) is absolutely essential when you add new devices in an Excel table that you plan to reload in GX IEC Developer later!
9 – 54
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.11
9.11.1
Forced Settings
Forced Settings
Forced Input/Output
By using the function Forced Input Output Registration/Cancellation it is possible to forcefully set or reset an input (X device) and output (Y device) of a PLC. The user can easily debug a program that is under execution in the PLC by intentionally setting or resetting the X/Y devices. The function facilitates a detailed study of input and output changes.
Fig. 9-55:
Menu Debug
NOTES
Once a device X/Y is forced to turn ON/OFF, its status is not affected by the input (X) from an external device and the output (Y) of the program. The forced input/output status can be cancelled only through the Forced Input Output Registration/Cancellation function.
Since the exclusive control is not exercised on the PLC CPU side, forcefully setting or resetting a device may cause the registration to be changed from multiple GX IEC Developer programs or from the equipment which can register/cancel forced devices.
The Forced input/output function is available only in Q series PLCs (except Q00(J)/01) and Q Remote I/O modules, but is not supported by the A, QnA and FX series.
The Forced input/output function is not supported by a standby system of a QnPRH PLC.
GX IEC Developer Reference Manual 9 – 55
Forced Settings Diagnostics Functions and Online Operation
Select Forced Input Output Registration/Cancellation in the menu Debug to open the following dialogue box.
Fig. 9-56:
Dialogue box Forced Input
Output…
NOTE
The forced input output registration and cancellation can be executed from the Forced input
output registration/cancellation dialogue. The device name entered in the dialogue can be forced to turn ON/OFF using the respective command button.
Most recently used devices can be automatically added by using the selection list Device. The maximum number of devices that can be stored in the Device list is 5. When the 6 th device is entered in the device name list, the least recently used or the very first entry in the list is deleted from it.
By pressing the button Set forced ON, the X/Y device entered/selected in the Devices list is set to ON regardless of the current device status.
When the Set forced OFF button is pressed, the X/Y device entered/selected in the Devices list is set to OFF regardless of the current device status.
The devices that are currently under forced input/output are displayed in a list in the dialogue so that the status of forced registration/cancellation can easily be checked.
Up to 32 devices can be set to forced ON/OFF.
When the Cancel it button is pressed, the forced ON/OFF status of the X/Y device entered/selected from the devices list Device is cancelled and the device name is also removed from the forced I/O devices display list.
9 – 56
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation Forced Settings
NOTE
9.11.2
To export the listed devices under forced ON/OFF press the Export forced device list button.
This opens a file save dialogue to select the path for saving the file. The default path is the project path. The default file name is “ForcedDeviceList.xls”. The file format is the Excel format.
For importing a saved device list press the Import forced device list button. A file open dialogue is opened to select the list file to be loaded. The default path is the project path. The default file name is “ForcedDeviceList.xls”.
By clicking on the button Update status it is possible to update the current status of the forced input/output devices in the list. All forced I/Os registered to the PLC CPU can be cancelled by clicking on the button Clear all .
The status of forced input or output devices is not modified until it is modified through this dialogue by the user.
Starting/Stopping a PLC
This function toggles the PLC CPU's RUN/STOP mode. To control SFCs in a project from other program parts, GX IEC Developer provides the following functions for the System Q/QnA
CPUs: Start, stop, and initialise.
Fig. 9-57:
PLC status display options in case of a redundant PLC system
Status of redundant PLC system: Shows the status of the redundant PLC system.
System A: Shows the status information of System A.
System B: Shows the status information of System B.
Set Remote Mode
쎲 Select to set the operating state of the PLC:
Run, Stop, Pause, Reset
쎲 Select to choose the target PLC for the remote mode change:
Control, Standby, System A, System B, Both
Execute: Sets the operating state of the PLC
Refresh: Re-reads the operating state information from the PLCs.
Close: Closes the dialogue box.
GX IEC Developer Reference Manual 9 – 57
Forced Settings Diagnostics Functions and Online Operation
How to start/stop a PLC
햲 Select the Start/Stop PLC command in the Online menu.
햳 Click on the desired mode in the right hand section of the dialogue window displayed.
햴 In a redundant system click on the desired target PLC in the right hand section of the dialogue window displayed.
햵 Confirm your selection with Execute.
You will be prompted for a confirmation when you attempt to switch from RUN to STOP mode. The current status of the PLC is shown in the left hand section of the dialogue box.
Stop PLC and Restart PLC during RUN mode
A Stop PLC dialogue is displayed when you attempt an operation in RUN mode that is only possible in STOP mode (e.g. Download to PLC). For the QnPRH PLCs in Backup mode, when both PLCs are involved in the operation, a dialogue is shown to inform you that both PLC need to be stopped.
Fig. 9-58:
STOP PLC dialogue when downloading to PLC
Fig. 9-59:
STOP PLC dialogue for all other functions
A Restart PLC dialogue is displayed after the PLC was stopped because of an operation that was only possible in STOP mode (e.g. Download to PLC). For the QnPRH PLCs in Backup mode, when both PLCs were involved in the operation, a dialogue is shown to inform you that both PLC will be restarted.
Fig. 9-60:
Restart PLC dialogue after Download to PLC
Fig. 9-61:
Restart PLC dialogue after other function
9 – 58
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.11.3
Setting the PLC Time
This function sets the time on the connected PLC or on all PLCs in a network.
Forced Settings
Fig. 9-62:
Set time dialogue
Connection target information: Shows the actual connection.
Clock setup: Set date, time, and day.
Specify execution target: You can select between Currently specified station, Specify all
stations, and Specify group in connection with the Group no. as the target for setting the internal clocks.
Specify execution unit: Set the board no.
Setup: Sets up the set time information.
Close: Closes the dialogue box.
GX IEC Developer Reference Manual 9 – 59
The Monitor Function Diagnostics Functions and Online Operation
9.12
The Monitor Function
The monitor function enables you to follow program execution and to check the status of operands/devices in runtime. The data for monitor mode is read from the PLC itself.
GX IEC Developer supports different monitoring modes:
쎲 Program Monitor
쎲 Entry Data Monitor
쎲 Header Monitor
쎲 Link Monitor (see page 5-11)
When the monitoring mode is activated all GX IEC Developer editing functions are disabled.
NOTE
9.12.1
Inheritance
The monitor mode is inherited to objects that are opened by other objects they depend on.
Therefore, the monitor mode does not need to be enabled for depending objects manually.
For the following actions the monitor mode will be inherited:
Action
Change instance of a function block
Zoom function block
Zoom function
Open transition from SFC body
Open action from SFC body
Open new windows during tracking
Monitor mode inherited to
New instance
Body of function block
Body of function
Transition
쎲
Transition elements of the body, if the transition is a variable or address
쎲
Transition condition editor
Action
쎲
Action association list editor
New window
Tab. 9-18: Inheritance of monitor mode
9 – 60
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.12.2
Monitor Mode Options
The Monitor Function
In the Extras - Options menu you can specify options for the monitor mode.
Fig. 9-63:
Monitor mode options
NOTE
9.12.3
Displayed String Length: Displaying long strings significantly reduces performance in monitoring mode. It is thus advisable to limit the number of characters to be displayed.
Pollrate: Interval at which the monitor polls the CPU, expressed in ms.
While monitoring at a low poll rate and rapidly changing activation of actions/transitions the system may be slowed down.
System Switching during Monitoring a Redundant System
If the control and standby systems are switched during monitoring, the monitoring continues automatically with the system selected in Transfer Setup
Transfer Setup setting
Not specified
Control system
Standby system
System A
System B
Physically connected
System A (Control)
System B (Control)
System A (Standby)
System B (Standby) not relevant not relevant not relevant not relevant
Monitoring before switch Monitoring after switch
System A (Control)
System B (Control)
System A (Standby)
System A (Standby)
System B (Standby)
System A (Control)
System B (Standby)
System A (Control)
System B (Control)
System A (Standby)
System B (Standby)
System A (Control)
System A (Standby)
System B (Control)
System B (Standby)
System B (Control)
System B (Control)
System A (Control)
System B (Standby)
System A (Standby)
System A (Standby)
System A (Control)
System B (Standby)
System B (Control)
Tab. 9-19: Switching between control and standby system
GX IEC Developer Reference Manual 9 – 61
The Monitor Function Diagnostics Functions and Online Operation
If the switch was caused by a transmission error in the tracking cable, the following message will be displayed:
Fig. 9-64:
Switching notification
If the switch was caused by a request from a network module, the following message will be displayed:
Fig. 9-65:
Switching notification
9.12.4
The Program Monitor
In the text and graphical editors the values of all visible variables are displayed in the editing window, and they are updated after every program scan. The variables shown are always those lying within the current editing window pane. If you scroll the contents of the window or change its size the system automatically shows the values of all new variables that come into the window, and stops displaying the values of all variables that move out of the window.
Inputs and outputs that are set are displayed in the colours corresponding to the colour parameter settings.
When you start monitoring in the Sequential Function Chart editor the active Steps in the current window are shown in the colours set in the parameters. This enables you to follow which Step is currently active.
How to open the Program Monitor window
햲 Switch to Online mode by activating Monitor Mode in the Online menu or clicking on the monitor mode icon:
Tool for activating the monitor mode
햳 Open and select the body of the POU that you wish to switch to monitoring mode.
햴 Select Start Monitoring in the Online menu.
Fig. 9-66:
Active inputs and outputs are identified in colour.
Register D100 takes the value 255 of the base-8 literal.
9 – 62
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Monitor Function
In addition to Program POUs you can also use the Program Monitor for function blocks and functions. When you activate monitoring for the operand status of function blocks GX IEC
Developer first prompts you to specify the Instance of the function block for which you wish to activate the Program Monitor.
Fig. 9-67:
In the body of the program there is a signal on the inputs and outputs of
Log_Add_1, which is an instance of function block FB_1.
Log_Add_2 (an instance of function block FB_1) has no signals on its
I/Os …
... as a result, no signals are displayed for the devices of function block FB_1 in Monitor mode.
In Monitor mode, there would be signals in the devices In_1, In_2 and
Out_1 of FB_1.
How to start monitoring of an IL editor in a normal window
햲 Activate the command Start Monitoring
Body in the Online menu.
When Body Window monitoring is started, Boolean and all other types of variables will be monitored in the un-split body window. If more than one variable or device is used in one line, monitored values will be displayed at subsequent tab stops.
Fig. 9-68:
Monitoring in an unsplit window
GX IEC Developer Reference Manual 9 – 63
The Monitor Function Diagnostics Functions and Online Operation
How to start monitoring of an IL editor in a split window
햲 Activate the command Start Monitoring
Split Window in the Online menu.
When Split Window monitoring is started, the editor will be split into two vertical columns. Boolean values will be monitored as usual in the left split window. All other devices and variable types will be monitored in the right split window, as in the ST editor Split Window monitoring.
NOTE
Fig. 9-69:
Monitoring in a split window
When the monitoring of an IL body is not started by one of the above mentioned menu items
(but e.g. with Online Monitoring Mode, or via zooming into a FB body), Split Window
Monitoring will be used.
9 – 64
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
NOTE
How to stop the Program Monitor window
햲 Activate the command Stop Monitoring in the Online menu.
If you experience difficulties in distinguishing symbols that are closely spaced e. g. the “-” and the “#” symbols in the example below in the default Arial font setting, switch to another font such as Courier New or Fixedsys for better viewing.
Display in Arial font
Fig. 9-70:
Display in Arial font
Display in Courier New font
The Monitor Function
Fig. 9-71:
Display in Courier New font
Refer to section for details on the font selection.
GX IEC Developer Reference Manual 9 – 65
The Monitor Function
9.12.5
Diagnostics Functions and Online Operation
The Entry Data Monitor (EDM) and the Header Monitor
The Entry Data Monitor can be used to group objects from the open project in order to obtain a display of their current status. Several windows can be opened at once. The Header Monitor essentially offers all the functions available in the Entry Data Monitor. The only difference, although an important one, is that calling up the Header Monitor automatically displays the objects of the active POU.
The status of the following objects can be monitored in the Entry Data Monitor: Global and
Local Variables, POUs and Tasks.
The central element of the Data Entry Monitor is a table which the user can configure himself.
The values in the table can be read from the CPU and also written back to the CPU after editing. There is also the possibility of writing the table, i.e. the grouped objects, and the configuration of the table into an external file, or of reading the data from an external file.
The table is restricted to a maximum of 16,383 rows and 255 columns. This means that a total of 4,177,655 cells can be managed. The number of objects in the table is limited only by the available memory on your computer.
A security function is available to prevent data being written into the CPU.
The worksheet
In the Online menu, the Entry Data Monitor command calls up the EDM window.
Fig. 9-72:
Entry Data Monitor worksheet
If a direct address (in the IEC and Mitsubishi Editor) was entered in lower-case letters, these characters will automatically be converted into upper-case letters.
Rows including Boolean objects are highlighted if the respective object is active. The colour is defined in the project settings.
By means of this option it is possible to monitor an object in the Mitsubishi
Kn
notation.
9 – 66
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Monitor Function
Example
Example
NOTE
K1M10 will monitor the relays M10 to M13.
The result is displayed in the result columns offering a suitable style, e.g. Value (bin), Value
(dec), Value (hex). The objects will be displayed in their respective representations.
쑶
Bit pattern of M0 to M7 is displayed as 1000 1101.
In the column Value (bin) it will be displayed as 1000 1101.
In the column Value (dec) it will be displayed as 141.
In the column Value (hex) it will be displayed as 8D.
In the Mitsubishi
Kn
notation object values cannot be changed.
쑶
The commands in the Edit and Tools menus can also be called up via the pop-up menu. The pop-up menu appears if you press the right-hand mouse button or press the key combination
¨.
The Edit menu
The following commands are available in the Edit menu when the window of the Data Entry
Monitor is active:
Insert Object: The Object List window appears containing all the objects available in the current project. The objects can be selected via a group filter and a type ahead input field.
Fig. 9-73:
Inserting an object from the Object
List
If the checkbox Include objects from
user libraries is checked, global variables and POUs in any installed user libraries are shown in the object list.
Next Object: The object following the currently selected object is inserted. If the selection marker is positioned on an Array entry, the next element of this Array is inserted. If the selection marker is positioned on a numbered entry, the element with the next number is inserted. In all other cases, the object with the next consecutive address is inserted. This command is only available if the selected row contains an elementary object and the selected object is not a sub-object.
Insert Forced Inputs (not for FX family and Q00(J), Q01 CPUs): Inserts all user-forced input devices into the EDM. The “Status” column indicates that they are “Forced” (see below).
Forced inputs can be cleared via Online - PLC Clear - Forced Inputs.
Insert Set Inputs (FX family and Q00(J), Q01 CPUs only): Inserts all user-set input devices into the EDM. The “Status” column indicates that they are “Set” (see below).
GX IEC Developer Reference Manual 9 – 67
The Monitor Function Diagnostics Functions and Online Operation
Insert Set Outputs: Inserts all user-set outputs into the EDM. The “Status” column indicates that they are “Set” (see below).
9 – 68
Fig. 9-74:
Indication of the output status in the Entry Data Monitor
Clear Device File: All forced or set inputs and outputs are stored in the
DeviceFile.MON
in the project path. This file is cleared.
Insert Row: A new row is inserted in front of the selected row. As the EDM does not offer copy and paste operations, you cannot insert several rows at once.
Delete Rows: The selected row is deleted. You can also delete several rows at once. This command is only available if the first object selected and the object after the last object selected are not sub-objects.
Delete All: All entries in the table and the table configuration are deleted. You are asked to confirm the command before it is executed.
Close: The EDM window is closed. All information is automatically saved. The information concerning the current settings is stored in the MMP703.INI file and is loaded as the default when the EDM is next called up.
The Tools menu
The following commands are available in the Tools menu when the window of the Entry Data
Monitor is active:
Read from PLC: The data are read from the PLC and displayed in the EDM table. This command is only available in Offline mode.
Write to PLC: The data from the EDM table are written to the PLC. A dialogue window appears which allows you to choose whether only the selected objects or all objects are to be transmitted. This command is only available in Offline mode.
Read from File: The file previously created with the Write to File command is called up. This command is only available in Offline mode.
Write to File: Both the grouped objects and the configuration of the table can be saved in an external file. This file has the file extension EDM. This command is only available in Offline mode.
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Monitor Function
Setup: The Setup dialogue window is opened, in which the EDM table can be configured and the security function activated.
Fig. 9-75:
The columns for the EDM table are compiled in consecutive rows.
Disable automatic search
If you enter a direct address into the Entry Data Monitor, the system searches automatically for a corresponding variable in the GVL of the project. If a variable has been found, the variable name is added to the Entry Data Monitor.
This feature can cause long delays if the projects include many global variables. To increase the performance of GX IEC Developer, disable the automatic search in the setup of the Entry
Data Monitor.
Monitor only visible objects in window
In the monitor mode all objects entered in the Entry Data Monitor are monitored, even if they are not visible. This feature can cause long delays if the window contains many EDM elements.
To increase the performance of GX IEC Developer, it is possible to monitor only visible objects in the Entry Data Monitor. This option is realised in the setup of the Entry Data Monitor:
The disadvantage of this option is that short delays may be caused during scrolling in the Entry
Data Monitor. These delays are caused by the registration, which is changed every time when the visible part of the window has been changed.
Always on top: Keeps the Entry Data Monitor always on top of other windows. This option can be enabled or disabled in the menu Tools or Context. If this option is active, a check mark is placed next to the menu item. Only one Entry Data Monitor can be on top.
List global variables used in POU
This function in the EDM Setup is used to switch the listing of global variables used in a POU on and off. When the setting is off, only local variables (those declared in the POU header) will be listed under the POU. When the setting is on, the list will also contain all global variables used in the POU’s body, actions and transitions.
GX IEC Developer Reference Manual 9 – 69
The Monitor Function Diagnostics Functions and Online Operation
The pop-up menu for configuring the table
The Shortcut menu appears if you select the desired row and click on the right-hand mouse button or press the key combination
¨.
Field list: The Field List contains the possible column entries for the EDM table.
Fig. 9-76:
Field list
Insert row: A new row is inserted in front of the selected row.
Delete row: The selected row is deleted.
Delete All: All entries are deleted. You are asked to confirm your choice before the command is executed.
The buttons for configuring the table
Close: The dialogue window is closed. The settings are saved.
Cancel: The operation is aborted. The settings are not saved.
Read Setup: The file previously created with the Write Setup is called up.
Write Setup: The table configuration can be stored in an external file. This file is given the extension SED.
Password: The password for the security function is defined here.
Security on/off: A security function is available to prevent data being written into the CPU.
The security function can be switched on or off. You are prompted for the password
.
9 – 70
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Monitor Function
How to open the Entry Data Monitor or the Header Monitor
햲 Activate the Monitor Mode command in the Online menu.
햳 Select the POU to be switched to Monitor Mode.
햴 Select the Entry Data Monitor or Header Monitor command in the Online menu. The dialogue window containing the EDM table appears.
How to insert an object
햲 Select any cell in the desired row. A selected cell is indicated by the double border. (If the Name or Address column is selected, you can now enter the name or address directly.)
햳 Select the Insert Object command from the Edit menu or from the pop-up menu.
햴 Select the desired object and click on OK. You can also select several objects in the list consecutively or selectively. You also have the possibility of transferring the entire list of
Global Variables, as well as the entire POU and Task pool.
or
쎲 Copy global declarations from a GVL into an EDM window (Cut, Copy and Paste or Ctrl+X,
Ctrl+C and Ctrl+V).
쎲 Copy entries within an EDM window (Cut, Copy and Paste or Ctrl+X, Ctrl+C and Ctrl+V).
쎲 Copy entries between two EDM windows (Cut, Copy and Paste or Ctrl+X, Ctrl+C and
Ctrl+V).
How to insert a 32-bit register
햲 As an IEC address: Enter the corresponding address in the Address (IEC) column, e.g.
%MD0.0.
As a MITSUBISHI address: Enter the two contiguous MITSUBISHI addresses in the
Name column, e.g. D3+D4.
How to change the values of the objects
햲 Select the desired values column.
햳 In the case of bit operands: You can switch between the two possible entries (0 and 1) by double-clicking or pressing the SPACE key.
In the case of word operands: Activate the Edit Mode (mouse click or m). Enter the desired value. GX IEC Developer only accepts valid entries. Pay attention to the correct format (decimal, octal, etc.). The Edit Mode remains active in the event of an incorrect entry.
GX IEC Developer Reference Manual 9 – 71
The Monitor Function Diagnostics Functions and Online Operation
How to open and close a structure
The word Structure in the Type column indicates a tree structure. If a tree structure is open, all the associated variables of the POU are displayed.
햲 Select the Name cell in the row containing a structure.
햳 Closing an open structure: The open structure is indicated by a minus sign in front of the name. Double-click on the Name cell or press the
§- key combination. This closes the tree structure.
Opening a closed structure: The closed structure is indicated by a plus sign in front of the name. Double-click on the Name cell or press the
§+ key combination. This opens the tree structure.
Open structure
Closed structure
Fig. 9-77:
Open and closed structures in the Entry Data Monitor
Arrays in the Entry Data Monitor
You can enter arrays in the Entry Data Monitor. All elements of the array can be read, written and set.
If the array is large it may not be possible to display all its elements on the screen at the same time. You can set the default number of elements to display to a maximum of 50 with the option
Extras - Options - General - Array Elements To Show.
You can also change this value in the prompt dialogue that is displayed when you open an array in the Entry Data Monitor.
Fig. 9-78:
Array Elements Selection
9 – 72
The entry in the Lower Bound field specifies the first array element to be displayed.
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.12.6
The Monitor Function
Changing variable values
The value of a variable can be changed in the Entry Data Monitor (EDM). Additionally the variable value can be changed directly in an editor (IL, MELSEC IL, Ladder, FBD, and SFC).
This is realised by means of new dialogues for simple data types, which can be opened in the monitor mode. The restriction to simple data types means that it is not possible to change the values of structured data types (e.g. DUTs).
Dialogue layouts
Three different dialogue layouts are available for changing a variable value in an editor:
a) Dialogue to toggle Boolean variables or devices
This dialogue appears, if you want to change a Boolean variable or device. This dialogue can be switched off by selecting the correspondent option in the dialogue. This setting is valid until you leave the monitor mode.
Fig. 9-79:
Modifying boolean devices
b) Dialogue to change numerical variables or devices
This dialogue appears, if you want to change a numerical variable or device. It contains the type and the current value of the variable or device. The new value can be entered either as a decimal or as a hexadecimal value.
Fig. 9-80:
Modifying numerical variables
GX IEC Developer Reference Manual 9 – 73
The Monitor Function Diagnostics Functions and Online Operation
For a Q Remote I/O module the Modify variable value functionality can only be used to modify device values, since a Q Remote I/O project does not have symbolic names (there are neither
GVLs nor POU headers). Because of this, the dialogue is different for the Q Remote I/O module.
Fig. 9-81:
Modifying numerical variables for a Q
Remote I/O module
By clicking on Ranges you get shown a list of valid device ranges for the current PLC.
Fig. 9-82:
Modifying numerical variables - Ranges
NOTE
The devices LB, LW, LX, LY cannot be monitored in GX IEC Developer, therefore they will not be displayed in the Available device ranges list of the Modify Variable Value dialogue.
9 – 74
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Monitor Function
Dialogue operations
There are the following dialogue operations:
쎲 Changing the value of a variable or device
After you have entered the new value in the edit control, press Enter or OK to leave the dialogue. A message will appear asking whether the value should be written to the
PLC. If the new value has a wrong format, a message in the dialogue appears and the value in the edit control is selected. In this case the value is not written to the PLC. For numerical data types (INT, WORD, DWORD, DINT), the value can be entered in the hexadecimal format.
쎲 Changing the name of a variable or device
After you have entered a new variable or device and left the corresponding edit control, the dialogue will be updated. If the variable can be monitored, the new name and the current value are displayed. The cursor is set to the edit control New Value.
The following objects are valid:
– global variables
– local variables which are declared in the POU of the active body
– direct addresses
쎲 Changing the display type
For numerical data types it is possible to switch the display format of the current value and the new value between decimal or hexadecimal. This option is disabled for Boolean variables or devices.
쎲 Updating the current value
The current value of the variable or device will be updated according to the poll rate of the monitor mode.
c) Dialogue to change string variables
This dialogue appears, if you want to change a string variable. It contains the type and the current value (character string) of the variable or device. The new value (character string) can be entered in the field New Value.
Fig. 9-83:
Modifying numerical variables
GX IEC Developer Reference Manual 9 – 75
The Monitor Function Diagnostics Functions and Online Operation
Example
Opening the dialogues
The dialogues to change the variable or device values can be opened in the monitor mode in the following ways for the corresponding windows:
a) SFC Body
햲 Choose Modify variable in the menu Online or use the shortcut [CTRL] + [F9].
If a transition with a variable or device is selected in the POU body, the corresponding dialogue with this variable or device is opened. If no transition with a variable or device is selected, the dialogue is empty and you can enter a variable or device.
햳 Double-click with the left mouse button on a transition with a variable or device. The corresponding dialogue with this variable or device is opened.
For a selected transition with the variable
OperationDone
:
Fig. 9-84:
Opened dialogue indicating respective variable or device
쑶
9 – 76
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Monitor Function
Example b) MELSEC IL / IL Body
햲 Choose Modify variable in the menu Online or use the shortcut [CTRL] + [F9].
If a variable or device is selected in the POU body, the corresponding dialogue with this variable or device is opened. If no variable or device is selected, the dialogue is empty and you can enter a variable or device.
햳 Double-click with the left mouse button on a variable or device. The corresponding dialogue with this variable or device is opened.
In IL for the selected variable
MotorVal
:
Fig. 9-85:
Opened dialogue indicating respective variable or device
Example c) Ladder / FBD Body
햲 Choose Modify variable in the menu Online or use the shortcut [CTRL] + [F9].
If a variable or device is selected in the body of the POU, the corresponding dialogue with this variable or device is opened. If no variable or device is selected, the dialogue is empty and you can enter a variable or device.
햳 Double-click with the left mouse button on a variable or device. The corresponding dialogue is opened with this variable or device.
Example in Ladder for the selected variable
MotorVal
:
Fig. 9-86:
Opened dialogue indicating respective variable or device
쑶
d) Navigator
햲 To open the dialogue select Modify variable in the menu Online or press the shortcut
[CTRL] + [F9]. The dialogue is empty and you can enter a variable or device.
쑶
GX IEC Developer Reference Manual 9 – 77
The Monitor Function Diagnostics Functions and Online Operation
9.12.7
Example
Display direct address of a variable
In the monitor mode the direct address instead of the symbolic name of global variables can be displayed. This is possible for global variables of simple data types in Ladder and FBD.
Toggle direct address and symbolic name
In the monitor mode direct address and symbolic name of a variable can be toggled.
햲 Select the symbolic name or direct address of a global variable and choose Toggle
variable in the menu Online or press the shortcut [ALT] + [F9].
햳 Press [CTRL] and double-click with the left mouse button on the symbolic name or direct address of the global variable.
Example in Ladder
A) Global variable
MotorVal
before calling the toggle functionality:
Fig. 9-87:
Symbolic name is indicated
B) Global variable
MotorVal
after the toggle functionality has been called:
Fig. 9-88:
After toggling direct address is indicated
If the monitoring is stopped for a window, the direct addresses of the toggled global variables are still available. If the monitor mode is finished, the symbolic names of the toggled global variables are restored.
쑶
9 – 78
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Monitor Function
9.12.8
NOTE
Tracking variables
The write access to variables can be tracked during monitoring. The tracking of variables is available within the IL, MELSEC IL, ST, LD, and FBD editors for the following objects:
쎲 POU bodies
쎲 SFC transitions
쎲 SFC actions
The tracking functions are available from
쎲 the menu Tools - Tracking.
쎲 the declaration and language editors context menu in
(right-click on variable or keys [SHIFT]+[F12]).
edit mode
and
non-edit
mode
쎲 the declaration editor context menu by [CTRL] + Double-click, to directly go to the location, where the identifier of a given row is first referenced.
(The jump to the first reference is initiated by double-clicking on a row while pressing the
[CTRL] key.)
Edit mode
refers to the state of a language editor, when the source code is being edited (i.e.
there is a text edit cursor) and in the case of a declaration editor, when one of the fields is being edited.
Non-edit mode
on the contrary is the state of an editor, when its content is not edited.
If the tracking function is started, a dialogue to enter the variable name and the access type (to search only for variables with write access or for all variables) appears. The tracking function is started, when the dialogue is closed with the OK button.
Fig. 9-89:
Tracking
The tracking function can be started in the menu bar, if the monitor functionality is switched off or switched on (not context sensitive).
If the monitor mode is switched on, the tracking functionality is also available in the context menu. The name of the variable, where the right mouse click was done, is used as the default variable name in the appearing dialogue.
The Start Tracking function creates an internal list (from the browser information). This internal list indicates where the selected variable name is used for write access. If this list already exists, it will be overwritten. A window will be opened showing where the variable name is used for the first time. In this window the corresponding variable is highlighted. If the corresponding variable name can not be found or if the browser information is not available, an appropriate message box will appear.
GX IEC Developer Reference Manual 9 – 79
The Monitor Function Diagnostics Functions and Online Operation
If the variable name could be found, the next, previous, first, and last occurrence of the variable can be tracked via menu commands. Each occurrence is shown in a window where the variable is highlighted. If the corresponding variable name can not be found or if the browser information is not available, an appropriate message box will appear.
Tracking menu items and functions
Start Tracking:
쎲 Open the browser.
쎲 The code location selected is the first entry in the browser list box.
쎲 Open the code location of the occurrence.
쎲 Mark the code location of the variable occurrence.
쎲 Start monitoring of the newly opened editor.
쎲 If no ‚First‘ is found, the following message box is displayed: ‘Start Tracking:
No reference found’.
Next:
쎲 According to the browser information the selection is set to the next occurrence.
쎲 Open the code location of the occurrence.
쎲 Mark the code location of the variable occurrence.
쎲 Start monitoring of the newly opened editor.
쎲 If no
Next
is found, the following message box is displayed: “No reference found”.
Previous:
쎲 According to the browser information the selection is set to the previous occurrence.
쎲 Open the code location of the occurrence.
쎲 Mark the code location of the variable occurrence.
쎲 Start monitoring of the newly opened editor.
쎲 If no ‚Previous‘ is found, the following message box is displayed: “Previous:
No reference found”.
First:
쎲 According to the browser information the selection is set to the first occurrence within the browser.
쎲 Open the code location of the occurrence.
쎲 Mark the code location of the variable occurrence.
쎲 Start monitoring of the newly opened editor.
쎲 If no
First
location”.
is found, the following message box is displayed: “Already placed on desired
9 – 80
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Monitor Function
NOTES
Last:
쎲 According to the browser information the selection is set to the last occurrence within the browser.
쎲 Open the code location of the occurrence.
쎲 Mark the code location of the variable occurrence.
쎲 Start monitoring of the newly opened editor.
쎲 If no
Last
location”.
is found, the following message box is displayed: “Already placed on desired
If the .scx file is not available and the .sct files are also not available, a dialogue will appear with the information, that the project must be checked or compiled with activated cross reference options. A button to call the corresponding options dialogue is also available.
If the .sct files are not available, a dialogue will appear with the information, that the project must be checked or compiled with activated cross reference options. A button to call the corresponding options dialogue is also available.
If the .scx file is not available and the .sct files are available, a dialogue will appear with the information, that the cross reference must be generated.
Limitations
If a variable is used in the MELSEC IL, the variable can not be displayed by the tracking function.
GX IEC Developer Reference Manual 9 – 81
The Monitor Function
9.12.9
Diagnostics Functions and Online Operation
Tracking Variables in a Redundant System
If default tracking settings are used, most system variables will automatically be tracked. There is, however, a problem if the device R is selected as the Word range of system variables because File Registers are not automatically tracked.
It is possible to set tracking ranges manually in the Redundant PLC Parameter dialogue (also
see sec. 5.2). In this case only the devices set by the user are tracked. Therefore the system
variables will not be tracked if the user does not specifically set all system variable ranges to be tracked.
The following table describes the default tracking ranges and the possible tracking ranges that may be set in the Redundant PLC Parameter.
Device Default tracking range Possible tracking range
Can be used as system variable
쎻
쎻
쏹
쎻
쏹
Input
Output
Internal Relay
Latch Relay
Step Relay
Annunciator
Edge Relay
Link Relay
Link Special Relay
Timer
Retentive Timer
Counter
Data Register
Link Register
Link Special Register
Index Register
Special Relay
Special Register
File Register
—
—
X0 to X1FFF
Y0 to Y1FFF
M0 to M8191
햲
L0 to L8191
햲
S0 to S8191
F0 to F2047 or the range set in
PLC Parameter
Devices
V0 to V2047
햲
B0 to B1FFF
햲
T0 to T2047
햲
SB0 to SB7FF
—
C0 to C1023
햲
D0 to D12287
햲
W0 to W1FFF
햲
— SW0 to SW7FF
See QnPRH user manual chapter 5.5.3 (2) (c)
See QnPRH user manual chapter 5.5.3 (2) (d)
Z0 to Z15
Not necessary; default range is always tracked in backup mode
Not necessary; default range is always tracked in backup mode
—
The range set in
PLC Parameter
PLC File, if any
Tab. 9-20: Default tracking ranges
쎻
쏹
쏹
쎻
쎻
쏹
쏹
쏹
쎻
쎻
쎻
쎻
쎻
쏹
쏹: Can be used as a System Variable
쎻: Can not be used as a System Variable
햲
If the number of devices is modified in PLC Parameter Devices, both the default and the possible tracking ranges change accordingly.
9 – 82
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation The Monitor Function
The following checks will be carried out, depending on the settings of the Redundant Parameter and the System Variables options:
If default tracking settings are used, the whole range of the following devices that may be used in system variables are tracked by default: D, W, T, ST, C, M, S.
It is not necessary to track P devices.
쎲 A warning dialogue is displayed if R devices are used as system variables.
If tracking ranges are set manually, then it is necessary to check all used system variable ranges against the set tracking ranges.
쎲 A warning dialogue is displayed if not all devices used as system variables are tracked.
쎲 A warning dialogue is displayed if all devices used as system variables are tracked, but in several different tracking blocks.
쎲 A warning dialogue is displayed if all devices used as system variables are tracked in one tracking block, to inform the user how to make sure that the block is actually tracked.
These checks will be executed during project check. If a problem is found, a warning will be
displayed in the Compile/Check Messages window. Please refer to section 8.2 for details.
If the situation is not corrected, a warning dialogue will be displayed when attempting to download the project.
GX IEC Developer Reference Manual 9 – 83
The Monitor Function Diagnostics Functions and Online Operation
9.12.10
Monitoring Boolean I/Os of function blocks
Boolean inputs and outputs of function blocks are monitored even if they are connected to a network. The function block itself does not need to be opened and monitored individually.
All Boolean inputs and outputs of a function block are monitored in the function block box, if the monitor mode is active. The Boolean variables of the value FALSE are indicated by a highlighted frame and the Boolean variables of the value TRUE are indicated by a completely highlighted rectangle.
Fig. 9-90:
Monitored inputs and outputs
9 – 84
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.13
9.13.1
In Cycle Monitor
In Cycle Monitor
In GX IEC Developer monitoring can be done at any valid step of the sequence program.
When doing „normal“ monitoring, the monitor values reflect the status of the monitored devices at the end of the scan cycle. When doing in cycle monitoring, the monitor values reflect the status of the monitored devices previous of executing the designated step.
Running the In Cycle Monitor
Two entries in the Online-menu allow starting and stopping of the In Cycle Monitor.
Fig. 9-91:
Menu command for starting the In Cycle Monitor
NOTES
The following conditions must be fulfilled to start the In Cycle Monitor:
쎲 A project must be open
쎲 The project’s PLC type is Q or QnA series
쎲 The PLC must be in RUN mode
쎲 Transfer Setup designates PLC Module or Net/10(H) Module as the PLC side I/F, and in the
Network route there is no specification or Net/10(H) selected
쎲 The monitor mode is off
쎲 The online change mode is off
쎲 The GX Simulator is not running
In Cycle Monitor is not available for SFC POUs (only the main program file MAIN.QPG is supported).
In Cycle Monitor is not available for the standby system of a redundant system in Backup mode. A corresponding message will be shown if an attempt for monitoring is made.
The In Cycle Monitor is not available for the A and FX series.
It is not possible to use “normal” monitoring for one window and in cycle monitoring for another. Once monitoring is started in In Cycle Monitor mode all monitoring is done at the designated step and vice versa.
GX IEC Developer Reference Manual 9 – 85
In Cycle Monitor Diagnostics Functions and Online Operation
Fig. 9-92:
Menu command for stopping the In Cycle Monitor
The „Stop In Cycle Monitor“ menu command will also stop monitor mode and vice-versa, if the command „Stop Monitoring“ mode is issued during In Cycle Monitoring, In Cycle Monitoring is stopped automatically.
If you are in In Cycle Monitor mode, but would like to monitor at another step, then first you will have to stop monitoring and start In Cycle Monitor again.
After starting the In Cycle Monitor, a dialogue box for input of the step number will be displayed:
Fig. 9-93:
Entry of the desired step number
NOTE
The step number is pre-initialised, if the In Cycle Monitor is started from one of the IL, MELSEC
IL or ST body editors and from the current editor position a step can be calculated. If for the current line no step number can be calculated, the previous lines are tried, until a step number can be calculated or the beginning of the network is reached.
The step number is also pre-initialised, if the In Cycle Monitor is started from one of the IL,
MELSEC IL, LD or FBD body editors and a network is selected. In this case the first step after the network is used for pre-initialisation. This means that the status after the network is executed is monitored.
If a step number cannot be calculated the dialogue is opened with the Step No. field empty.
The Step No. field cannot be initialised if
쎲 the actual window is not an IL, MELSEC IL, LD, FBD or ST body editor
쎲 the body is not compiled
쎲 an empty network is selected
쎲 more than one network is selected
If the designated step is not executed (e.g. the step is jumped or the PLC is in STOP mode), no monitoring values can be read and a communication error will occur.
9 – 86
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation In Cycle Monitor
Example
How to calculate the step number to input?
With In Cycle Monitoring, the monitor values shows the status of the monitored devices previous of executing the designated step. This means, that the actions of the step set as the In
Cycle Monitoring step, do not effect the monitor values.
If you would like to monitor the results of a step, for In Cycle Monitoring you must set the result of the addition
„starting step number of the desired instruction“ + „length of the desired instruction“.
For convenience, the Tools -> Show MELSEC Code Of Networks functionality can be used, where the start step of each instruction is displayed (in brackets at the end of each line).
The following example shows 12 steps of code, generated for a Q06H PLC. The code snippet occupies step 14 through 26. After the code lines the start step number is written in brackets.
Every LD instruction for the Q06H PLC occupies 1 step each, whereas a MOV instruction occupies 2 steps.
LD
MOV
SM400
K1111
D1
(*
(*
15 *)
16 *)
Fig. 9-94:
Program sequence for the example
LD
MOV
(*
(*
18 *)
19 *)
LD
MOV
LD
MOV
SM400
K2222
D1
SM400
K3333
D1
SM400
K4444
D1
(*
(*
21 *)
22 *)
(*
(*
24 *)
25 *)
In these 12 steps of PLC program the value of the device D1 is changed four times, by four different MOV instructions.
The value of the device D1 is not changed elsewhere in the PLC program.
If you would monitor the device D1 in „normal“ monitor mode, the value would be 4444, as this is the last setting.
As an example, if you would like to monitor the result of the MOV instruction at step 22, you must add 2 (length of MOV instructions) to the start step (22). The result is 24, which is also the start step of the following instruction, of course.
GX IEC Developer Reference Manual 9 – 87
In Cycle Monitor Diagnostics Functions and Online Operation
For the in cycle monitoring mode the following table shows the monitored values corresponding to the set in cycle monitor step:
Step No.
… 14
15 or 16
18 or 19
21 or 22
24 or 25
27 …
Monitored value of D1
4444
4444
1111
2222
3333
4444
Tab. 9-21:
Monitored value for the example
쑶
Before in cycle monitoring is started the validity of the step is checked both in the project and on the PLC. If the step is found invalid or the program on the PLC does not have the same instruction at the same step, in cycle monitoring is aborted. A step is considered valid for in cycle monitoring, if it is in the range of the program and it is the start step of any instruction. In the above example, steps 17, 20, 23 and 26 would not be accepted.
During the operation of the In Cycle Monitor a dialogue box informs you about the selected step number:
Fig. 9-95:
Display of the monitored step no.
If the step selected for In Cycle Monitoring is invalid or not executed by the PLC, it can take longer than the communication time-out setting for the PLC to return an error, and afterwards to terminate In Cycle Monitoring.
A status dialogue is displayed when In Cycle Monitoring is started or terminated, until the process is finished. The estimated time depends on the communication time-out setting.
Fig. 9-96:
Status dialogue
9 – 88
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation Buffer Memory Monitoring
9.14
NOTES
Buffer Memory Monitoring
Using the function of Buffer Memory Batch in the menu Debug you can monitor the current values of the buffer memory of a special function module attached with the active PLC. The monitoring can be started and stopped from the buffer memory monitor window. For displaying the monitored values you can select different user defined monitor, display and value formats.
The formats can be changed by clicking the radio buttons in the function dialogue box.
The function of Buffer Memory Batch is not supported by the PLCs of the FX series.
GX Simulator (section 9.15) does not support buffer memory monitoring.
When using the function Buffer Memory Batch some menu items like Object, Edit and
Tools are not available.
When selecting Buffer Memory Batch in the Debug menu the following dialogue box will be displayed.
Fig. 9-97:
Dialogue box Buffer
memory batch monitor
Module start address: Enter here the I/O address (lowest digit not required) of the special function module whose buffer memory you want to be monitored. The module start address should be input in hexadecimal format.
Buffer memory address: Here the start address of the buffer memory block that is to be monitored has to be set. The address can be in either decimal or hexadecimal format according to
the value format option selected (see section 9.14.3).
Monitor format: Please see sections 9.14.1 to 9.14.3.
Start monitor: Click here to start the buffer monitor function.
Stop monitor: Click here to stop the buffer monitor function.
Option setup: Clicking on this button opens a dialogue box to select the bit order for displaying the buffer memory monitor values.
Fig. 9-98:
Dialogue box Option setup
GX IEC Developer Reference Manual 9 – 89
Buffer Memory Monitoring Diagnostics Functions and Online Operation
Device test: Clicking on this button opens a dialogue box for device test.
Fig. 9-99:
Dialogue box Device test
Module start I/O: In this pull-down list select the start I/O address of the module in which the buffer memory device for testing is available.
Address: Select a buffer memory address for testing from this pull-down list.
Close: Clicking on this button closes the dialogue.
Setting value: Here you can input the value to be set in the selected buffer memory address.
By clicking on the Set button the input value is set to the selected buffer memory address.
Hide history: Clicking on this button shows/hides the device test history panel in the Device test dialogue.
Execution history: This history list shows the device tests made using the Device test dialogue. Here the devices and their setting values are displayed.
Re-setting: Sets the selected device and its associated value from the history panel to the
Setting value box. To finally set the value in buffer memory you have to click on the Set button.
Clear: This button deletes all data of the history.
9 – 90
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.14.1
Buffer Memory Monitoring
Monitor Formats
You can select one of the following formats for buffer memory monitoring.
쎲 Bit & Word
The buffer memory can be monitored by having displayed both Bits and Words as shown below.
Fig. 9-100: Monitoring option Bit & Word
쎲 Bit only
The buffer memory can be monitored by having displayed only Bits as shown below.
Fig. 9-101: Monitoring option Bit only
쎲 Word only
The buffer memory can be monitored by having displayed only Words as shown below.
Fig. 9-102: Monitoring option Word only
GX IEC Developer Reference Manual 9 – 91
Buffer Memory Monitoring
9.14.2
Diagnostics Functions and Online Operation
Monitor Display
When you have chosen one of the monitor format options Bit & Word or Word only you can additionally select one of the following display options for the buffer memory monitoring value.
This option only applies to the monitoring values in Word format.
쎲 16-Bit-Integer
The monitoring values will be displayed in 16-Bit-Integer.
Fig. 9-103: Monitoring option 16bit integer
쎲 32-Bit-Integer
The monitoring values will be displayed in 32-Bit-Integer.
Fig. 9-104: Monitoring option 32bit integer
쎲 Real number
The monitoring values will be displayed as Real numbers.
Fig. 9-105: Monitoring option Real number
쎲 ASCII character
The monitoring values will be displayed as ASCII characters.
Fig. 9-106: Monitoring option ASCII character
9 – 92
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.14.3
Buffer Memory Monitoring
Monitor Value
When you have chosen one of the monitor format options Bit & Word or Word only you can additionally select one of the following value options for the buffer memory monitoring value.
This option only applies to the monitoring values in Word format.
쎲 Decimal
The monitoring values will be displayed in decimal format.
Fig. 9-107: Monitoring option DEC (10)
쎲 Hexadecimal
The monitoring values will be displayed in hexadecimal format.
Fig. 9-108: Monitoring option HEX (16)
GX IEC Developer Reference Manual 9 – 93
GX Simulator Diagnostics Functions and Online Operation
9.15
NOTE
GX Simulator
The GX Simulator is a utility for offline simulation and debugging of PLC programs. It provides the simulation of external devices, load and save buffer memory contents, timing charts and much more.
Step execution is also supported even for an FX CPU.
GX Simulator can only be started, if the tool is installed, the project is compiled, and GX IEC
Developer is not in online-mode.
In the Online menu select GX Simulator. The PLC parameters are transferred to GX Simulator and the main GX Simulator window appears. It shows the PLC CPU condition and allows to start different tools.
Fig. 9-109:
GX Simulator main window
The device memory monitor of the GX Simulator shows the values of the selected devices and allows to change them.
9 – 94
Fig. 9-110: Device Memory Monitor
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation GX Simulator
The timing chart shows the condition of the selected devices within a selected timing range.
Fig. 9-111: Timing Monitor
NOTE
It is not possible to perform online changes. Rounding errors may occur in the results of instructions using the floating decimal point.
After the error correction by the GX Simulator program module the program must be transferred to the specified PLC and checked again before it is executed.
The following functions are not supported:
쎲 Physical special function modules
쎲 Physical I/O modules
쎲 Networks
쎲 Interrupt programs
쎲 Read from PLC, Compare with PLC
쎲 Comments
쎲 SFC programs
There are other CPU related restrictions in device ranges, PLC memory format, etc. For more details refer to the manual for the GX Simulator.
GX IEC Developer Reference Manual 9 – 95
Intelligent Function Module Utility Diagnostics Functions and Online Operation
9.16
NOTES
Intelligent Function Module Utility
The included intelligent function module utility has to be installed separately. It supports an easy configuration of intelligent function modules by dialogue based input instead of PLC program code needed to access the module buffer memory setup area.
The utility is available only if a Q series project is active and the utility is installed. The utility supports the Q series only. For details refer to the documentation of the utility.
GX IEC Developer supports the call of the intelligent function module utility and a check for address collisions between refresh parameters for the modules and GX IEC Developer system addresses. The configuration file has to be written by the intelligent function utility to the PLC and to the hard disk. A corresponding message is displayed by GX IEC Developer if the utility is started.
If initial setting and automatic refresh setting are performed, the intelligent function module parameters require a maximum of 76 bytes per module.
If the project is saved with a different name, GX IEC Developer informs the utility about a closed project because the iparam.wpa file of the old project path is not saved with the new project! The iparam.wpa file is the configuration file, created by the utility. It can be found in the subdirectory
Resource
of the current project. You have to close the utility, and copy the iparam.wpa file from the old project to the new one.
After configuration of the intelligent function module, please save the parameters to hard disk!
The intelligent function module utility will be closed, if the current project is closed or changed. Please remember to save the configuration BEFORE closing or changing the project.
9 – 96
MITSUBISHI ELECTRIC
Diagnostics Functions and Online Operation
9.16.1
Intelligent Function Module Utility
Starting the utility
From the Extras menu select Intelligent Function Utility - Start to start the external utilities and navigate via the utility’s menus.
From the Extras menu select Intelligent Function Utility - Verify System Variables to start the external utilities and directly verify the system variables.
Address collisions between refresh addresses and GX IEC Developer system addresses.
Fig. 9-112:
Notified address collisions
Intelligent function module utility with configuration for three different modules.
Fig. 9-113:
Intelligent function module utility
GX IEC Developer Reference Manual 9 – 97
Intelligent Function Module Utility Diagnostics Functions and Online Operation
Example
Example for the auto refresh configuration of the A/D conversion Module Q64AD.
9.16.2
Fig. 9-114: Sample auto refresh settings
Troubleshooting
In very rare cases problems might occur which will be solved in future software versions.
햲 Problem: If GX IEC Developer 7.03 is already installed before installing GX Developer
(Version < 8.00)
, the Intelligent Function Utility can not be started anymore from
GX IEC Developer 7.03.
Solution: Install GX IEC Developer 7.03 again.
햳 Problem: If GX Developer
(Version < 8.00)
is already installed before installing
GX IEC Developer 7.03, GX Developer can not be started anymore.
Solution: Install GX Developer again in a newer version
(Version > 8.00)
.
햴 Problem: If GX Developer as well as GX IEC Developer 7.03 are installed and
GX Developer will be uninstalled afterwards, the Intelligent Function Utility can not be started anymore from GX IEC Developer 7.03.
Solution: Install GX IEC Developer 7.03 again.
쑶
9 – 98
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before
10
External Variables are no longer used
Working with Projects of Version 6.11
and before
This chapter describes major changes in the new version of the GX IEC Developer compared to earlier versions. So reading this chapter is important for users who want to use projects with the GX IEC Developer 7.03 that have been created by using the GX IEC Developer 6.11 or an
earlier version. Please also see section 10.4.
10.1
10.1.1
External Variables are no longer used
Instead of using external variables, every global variable can be directly accessed from any
POU since version 7.00 of GX IEC Developer.
This means that in a POU body, action or transition every variable will be accessible that is declared either global or local in the respective scope. A global variable declaration can either take place in the Global Variable List of the project or in any user library.
Using Global Variables in Bodies
Every global variable is now accessible from any POU body, action or transition, without declaring it as an external variable in the POU scope. Global variables will be usable the same way as any local variable.
When there is a local variable declared in a POU with the same name as a global variable, the global variable is hidden, i.e. it is not possible to read or write the value of that global variable – always the local variable is referenced instead.
GX IEC Developer Reference Manual 10 – 1
External Variables are no longer used Working with Projects of Version 6.11 and before
Example
In the example below there are both global and local variables used in a POU body.
There are three variables in the POU’s header whose names are identical with global variable names:
Count
,
MotorOff
and
Frequency
. These local variables hide the corresponding global variables, so when e.g.
Count
is used in the POU’s body, it means the local variable
Count
, not the global variable
Count
.
hidden global variables
Fig. 10-1:
Global and local variables with the same name
쑶
10 – 2
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before
10.1.2
External Variables are no longer used
Compiler Options
Two new options are introduced on the Compiler page of the Options. One is to allow you to choose if global variable hiding should be considered as a programming error or not, the other one is to allow you to choose if using lower case device/constant names used as variable names should be considered as a programming error or not.
Please refer to section 2.9.2 for additional information.
Fig. 10-2:
Options - Compiler
Hiding global variables
By default, if a local variable of a POU has the same name as a global variable, an error will be shown when the POU is checked. If you turn this option on, hiding of global variables will be allowed and the POU will be compiled.
POUs that have been already compiled without error and have not been changed since the compilation are not checked or built again when the corresponding menu command Object
Check or Project Build is called.
Consequently, for already compiled POUs changing the option “Allow local variable with the same name as a global variable” from checked to unchecked has no effect, unless the whole project is recompiled by calling the menu item Project Rebuild All.
GX IEC Developer Reference Manual 10 – 3
External Variables are no longer used Working with Projects of Version 6.11 and before
Using lower case device/constant names
The following programming is possible in GX IEC Developer:
쎲 Using X1 and X2 variables in a body (either typed with caps, or automatically converted by the editor) with no declarations in the header or GVL.
Result: Devices are used in the generated code.
Fig. 10-3:
Using X1 and X2 variables in a body with no declarations
쎲 Using X1 and X2 variables in a body (either typed with caps, or automatically converted by the editor) with x1 and x2 declarations in the header or GVL.
Result: Variables are used in the generated code.
10 – 4
Fig. 10-4:
Using X1 and X2 variables in a body with declarations
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before External Variables are no longer used
To give the user a hint, that a Mitsubishi device or constant could be hidden by a variable declaration with lower case letters the new option is added to the General Options\Compiler option.
If the option is checked, the following warning is shown when a Mitsubishi device/ constant name is used as variable name in a lower case format:
Warning: C9173 The variable ‘%s’ could hide a Mitsubishi device/ constant. Make sure you want to use the variable instead.
If the option is unchecked, the following error is shown when a Mitsubishi device/ constant name is used in a lower case format as variable name:
Error: C9172 The variable ‘%s’ has the same name in lower case format as a
Mitsubishi device/ constant. This error can be converted to a warning in General
Options\ Compiler.
In the LD/FBD and ST editor Mitsubishi devices are already converted to upper case when they are entered in lower case format. Since GX IEC Developer 7.00 this is extended to convert
Mitsubishi constants, too.
10.1.3
Example
Variable Declaration
Variable Declaration in the Declaration Editors
The global variable list and POU header editors were modified to comply with the new convention. In the GVL editor the Autoextern checkbox column was removed, because every global variable now is accessible from any POU.
In the POU header editor VAR_EXTERNAL and VAR_EXTERNAL_CONSTANT were removed from the list of available classes. Moreover, the button column on the right of the Identifier column also is removed, because it was used to access the dialogue to select the name of an external variable from the list of global variable names.
Example of the changed Global Variable List editor:
Fig. 10-5:
Sample of GVL
Example to the changed POU header editor:
Fig. 10-6:
Sample of POU Header
GX IEC Developer Reference Manual 10 – 5
External Variables are no longer used Working with Projects of Version 6.11 and before
Variable Declaration in the Variable Selection Dialogue
The variable declaration part of the Variable Selection dialogue has also been modified to comply with the changed variable scope convention.
The Autoextern checkbox was removed from the dialogue, and the external variable classes
(VAR_EXTERNAL and VAR_EXTERNAL_CONSTANT) are no longer available in the Class list when the scope of the Variable Selection dialogue is set to <Header>.
Fig. 10-7:
Variable Selection Dialogue
Declaration of a SFC Reset Variable
In each SFC POU of an FX project a Boolean variable can be specified to be used to trigger the reset of all steps and the set of the initial step. This variable can be either local or global
(external in previous versions).
Formerly a variable was specified to be such a SFC reset variable by setting its comment field in the POU header to “!RESET!” (the first variable in the POU header with the comment
“!RESET!” was used as SFC reset variable).
With the removal of external variables, this is not possible anymore, because a global variable can not be specified to be the reset variable for a POU, as it is not in the header of the POU.
The assignment of a SFC reset variable to a SFC POU of an FX project is introduced in the
POU information dialogue. When calling Object Information for a SFC POU in an FX project, the dialogue will provide the setting for the SFC reset variable.
Fig. 10-8:
Function Information
Dialogue
10 – 6
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before External Variables are no longer used
NOTES
The SFC reset variable can be a local or global variable with the type BOOL or ARRAY OF
BOOL. When an ARRAY OF BOOL variable is given, its first element will be used as the reset variable.
By pressing the function key F2 the dialogue Variable Selection can be called to select and apply a variable for SFC reset.
When pressing OK in the dialogue, the syntax of the entered name will be checked, but it will not be verified whether the entered name specifies an existing variable. When the POU or the project is checked (or built), and the SFC reset setting does not specify a valid variable, an error will be added to the list of errors and warnings in the Compile/Check Messages
dialogue. See section 8.1 for details.
10.1.4
Update Variables
The function of updating variables is enabled when at least one declaration is selected in an active GVL or POU header editor; is disabled in Monitoring mode. It is disabled in POU header editors if the POU does not have a write-accessible body and in GVL editors if the GVL is in the
Standard or the Manufacturer library, or if it is in a read-only user library.
Formerly when the functionality Extras Update Variables was called in a GVL, every reference in the project to the selected variable(s) – including all user libraries – was updated.
Variable update meant that in all POU headers the external variable(s) referring the selected global variable(s) were synchronized with the global variables, so that their type, address and other properties matched.
Furthermore, if the name of a global variable was changed, not only the corresponding external variables were updated in the POU headers, but also all occurrences of those external variables in the POU bodies.
With the removal of external variables, POU headers do not have to be updated when a global variable is updated. If the name of a global variable is changed, Update Variables will change all occurrences of that global variable in each POU.
When the Auto Update feature is switched on in the Editing page of the Options (
update of changed variables will be performed automatically each time the GVL is saved.
The behaviour of Extras Update Variables remains the same as in former versions when called in a POU header: all occurrences of selected local variables whose name has been changed will be updated in the POU.
GX IEC Developer Reference Manual 10 – 7
External Variables are no longer used
10.1.5
Working with Projects of Version 6.11 and before
Import from Excel
When importing a Microsoft Excel file into a POU header, the file is checked for external variables in it.
If one or more variables with the class VAR_EXTERNAL or VAR_EXTERNAL_CONSTANT are found, you will be warned that these variables will be skipped.
Fig. 10-9:
Warning message
Example
Fig. 10-10: External variables are skipped
쑶
10 – 8
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before
10.1.6
External Variables are no longer used
ASCII Import and Export
ASCII Import
When you import data from an ASCII export file that includes the Global Variable List (e.g. a complete project exported), the external variables will be automatically removed from the POU headers (including the POUs in user libraries).
When you import data from an ASCII export file that contains no Global Variable List, each imported POU header will be checked for external variables. If one or more variables with the class VAR_EXTERNAL or VAR_EXTERNAL_CONSTANT are found, you will be warned that the variable(s) will be skipped.
This message will not be displayed when you are importing an ASCII export file that was created by GX IEC Developer version 7.00 or newer.
Fig. 10-11:
Warning message
In FX projects before version 7.00, SFC reset variables were assigned to the POUs based on declaration comments, i.e. in each POU the first variable having the comment “!RESET!” was set to be the SFC reset variable of the POU. During ASCII import the SFC reset variable will be assigned to the POU information. When you call Object Information for the SFC POU of the FX project, you can check the setting of the SFC reset variable.
ASCII Export
To keep compliance with the IEC standard, when exporting the project or any part of the project that includes at least one POU, the global variables used in each POU will be automatically declared as external variables of those POUs in the exported ASCII file. If such an exported file is imported in a new GID version working without external variables, the external variables will be removed from the headers. If it is imported in a previous version of GID, external variables will be imported as usual.
For FX projects, to keep compliance with the IEC standard, the SFC reset variable of a POU will be exported by setting the variable declaration’s comment field to “!RESET!”. This is because the SFC reset variable is a special GX IEC Developer feature, for which there is no standard IEC definition. When a global variable is used as a reset variable for a POU, the automatically declared external variable (please see "Declaration of a SFC Reset Variable" in
section 10.1.3) will get the “!RESET!” comment.
When the comment field of a variable that is used as the SFC reset variable is not empty or is not equal to “!RESET!”, you will be warned that the comment field of that variable will be overwritten in the export file.
Fig. 10-12:
Warning message
GX IEC Developer Reference Manual 10 – 9
External Variables are no longer used Working with Projects of Version 6.11 and before
If there is already another variable in the POU header with the comment “!RESET!”, you will be offered to set the comment of the actual SFC reset variable to “!RESET!” and clear the comment field of other variables having the comment text “!RESET!”.
This change affects only the ASCII export file, not the project.
Fig. 10-13:
Warning message
10 – 10
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before
10.1.7
External Variables are no longer used
User Libraries
Installing Libraries
When installing user libraries, external variables will be removed from the header of each POU installed into the project from the user library. The removal affects only the POUs installed into the project, the user library file will be kept unchanged.
In FX projects, SFC reset variables will be assigned to the POUs based on declaration comments, i.e. in each POU the first variable having the comment “!RESET!” will be the SFC reset variable of the POU. Since version 7.00 the SFC reset variable is assigned to the POU information.
Saving Libraries
To keep compliance with the IEC standard, user libraries will be saved to the corresponding user library file, so that for each POU the global variables used in the POU will be automatically declared as external variables in the header of that POU.
This ensures that user libraries saved in GID 7.00 or later are compatible with former GID versions, starting from version 4.00.
If the user library is installed in a new GID version working without external variables, the external variables will be removed from the headers.
If a user library saved in the new GID version is installed in a former GID version, it will be able to use it without any problems because the necessary external variables will be declared.
For FX projects, to keep compliance with the IEC standard, the SFC reset variable of a POU will be saved so that it will work also when the user library is installed in a former GX IEC Developer version. Because of this the variable’s comment will be set to “!RESET!”.
When the comment field of a variable that is used as the SFC reset variable is not empty or is not equal to “!RESET!”, you will be warned that the comment field of that variable will be overwritten in the user library file.
Fig. 10-14:
Warning message
GX IEC Developer Reference Manual 10 – 11
External Variables are no longer used Working with Projects of Version 6.11 and before
If there is already another variable in the POU header with the comment “!RESET!”, you will be offered to set the comment of the actual SFC reset variable to “!RESET!” and clear the comment field of other variables having the comment text “!RESET!”.
This change affects only the user library file, not the project.
Fig. 10-15:
Warning message
10 – 12
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before
10.1.8
External Variables are no longer used
Browser
In the Browser window the VAR_EXTERNAL and VAR_EXTERNAL_CONSTANT classes are no longer available in the Scope list.
When a global variable is selected in the left hand side list, the location of its declaration (the
GVL of the project or a user library) will be shown on the right hand side list, together with the references to it.
Formerly there could be several items in the Declaration part of the right hand side list for a global variable, because external variable declarations were listed as well.
With the removal of external variables only the GVL declaration is listed for a global variable.
Fig. 10-16:
Browser dialogue
GX IEC Developer Reference Manual 10 – 13
External Variables are no longer used
10.1.9
Working with Projects of Version 6.11 and before
Entry Data Monitor
The setting List global variables used in a POU in the EDM Setup is used to switch the listing of global variables used in a POU on and off.
When the setting is off, only local variables (those declared in the POU header) will be listed under the POU.
When the setting is on, the list will also contain all global variables used in the POU’s body, actions and transitions.
Fig. 10-17:
Setup dialogue
10 – 14
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before
10.2
10.2.1
Opening Projects saved by former Versions
Opening Projects saved by former Versions
Opening older projects
When opening a projects saved by a former version of GX IEC Developer, the project will be converted according to the new variable scope convention:
쎲 External variables will be removed from each POU’s header (including POUs in user
libraries) (also see section 10.2.2).
쎲 SFC reset variables in FX projects will be assigned to the POUs based on declaration comments, i.e. the first variable having the comment “!RESET!” will be the SFC reset
variable of the POU (also see section 10.2.3).
쎲 The objects of an SFC POU (steps, actions and transitions) conflicting with global variable names will be offered to be automatically renamed.
The objects of an SFC POU (steps, actions and transitions) are not allowed to be named the same as any local or global variable accessible from the POU. Before GX IEC Developer
Version 7.00 a global variable could be used in a body only if it had been declared in the POU as an external variable, therefore an SFC object could have the same name as a global but non-external variable.
Since GID 7.00 each global variable is accessible in every POU, therefore the name of an SFC object may be the same as the name of any global variable. This leads to the problem that a project that could be compiled in a former version could cause an error in GID 7.00 or later when building the project, if it had one or more SFC objects sharing names with global but non-external variables.
If a project last saved with a GX IEC Developer version preceding 7.00 is opened, or a project is imported from an .ASC file using File
씮 Other 씮 Import, SFC objects conflicting with global variable names will be offered to be automatically renamed.
Fig. 10-18:
Auto-renaming SFC POU objects
Yes: This renames the mentioned SFC object.
Yes All: Renames the mentioned and following problematic SFC objects without showing this dialogue again.
No: Does not rename the mentioned SFC object.
No All: Does not rename the mentioned nor the following SFC objects.
Automatic renaming sets an index number at the end of the name, or increases it if there is one.
If the name is too long, the last character will be cut before numbering. If the new name would conflict with a device name, the index number will be separated with an underscore character
(e.g. X_1 instead of X1).
If the conflicting SFC object is not write-accessible, no renaming will be offered. Any unresolved conflict will cause an error during build, and can then be fixed manually by the user.
GX IEC Developer Reference Manual 10 – 15
Opening Projects saved by former Versions
10.2.2
Working with Projects of Version 6.11 and before
Copying and Moving Variables
When inserting variables into the POU header of GX IEC Developer 7.00 or later from a POU header editor of a for mer GX IEC Developer version via clipboard operations
(Copy/Cut/Paste) or Drag & Drop, variables with the class VAR_EXTERNAL or
VAR_EXTERNAL_CONSTANT will be skipped. This applies also to the case when variables are dropped from a declaration list of a former GX IEC Developer version onto a POU header in the project navigator window.
To easily create a local variable with the same properties as a global one, when a variable with the class VAR_GLOBAL or VAR_GLOBAL_CONSTANT is copied to a POU header, its class will be changed to VAR or VAR_CONSTANT, respectively. This is also possible in the opposite direction: VAR_CONSTANT converts to VAR_GLOBAL_CONSTANT, while all other classes convert to VAR_GLOBAL.
Fig. 10-19: Sample for copying and moving variables
10 – 16
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before
10.2.3
Opening Projects saved by former Versions
Clipboard Operations and Drag & Drop in the Project Navigator
When a selection including one or more POUs and the Global Variable List is copied or moved from a project opened in a former GID version to a project opened in the new GID version by clipboard operations (Copy/Cut/Paste) or Drag & Drop, external variables will be removed from POU headers.
If the copied or moved selection includes one or more POUs but no Global Variable List, the header of each selected POU will be checked for external variables. If one or more variables with the class VAR_EXTERNAL or VAR_EXTERNAL_CONSTANT are found, you will be warned that the variables will be skipped.
This message will be displayed only when copying or moving data from a project opened in a
GX IEC Developer version preceding version 7.00.
Fig. 10-20:
Warning message
In FX projects, SFC reset variables will be assigned to the POUs based on declaration comments, i.e. in each POU the first variable having the comment “!RESET!” will be the SFC reset variable of the POU.
To keep compliance with the IEC standard, when a selection including one or more POUs is copied or moved by clipboard operations (Copy/Cut/Paste) or Drag & Drop from a project opened in the new GID version to a project opened in a former GID version, the global variables used in each POU will be automatically declared as external variables in the POU’s header in the destination project. As a result, former GID versions – working with external variables – will be able to compile a copied POU without any problems.
For FX projects, to keep compliance with the IEC standard, the SFC reset variable of a POU will be copied by setting the variable declaration’s comment field to “!RESET!”. When a global variable is used as the reset variable of a POU, the automatically declared external variable
(see previous paragraph) will get the “!RESET!” comment.
When the comment field of a variable that is used as the SFC reset variable of the POU is not empty or is not equal to “!RESET!”, you will be warned that the comment field of that variable will be overwritten when copied. This warning will be displayed only for clipboard operations, not for drag & drop. For drag & drop “Yes All” is assumed as the user’s answer.
Fig. 10-21:
Warning message
GX IEC Developer Reference Manual 10 – 17
Opening Projects saved by former Versions Working with Projects of Version 6.11 and before
If there is already another variable in the POU header with the comment “!RESET!”, you will be offered to set the comment of the actual SFC reset variable to “!RESET!” and clear the comment field of other variables having the comment text “!RESET!”.
This change affects only the declaration copied to the clipboard, not the declaration in the project. This warning will be displayed only for clipboard operations, not for drag & drop. For drag & drop “Yes All” is assumed as the user’s answer.
Fig. 10-22:
Warning message
10 – 18
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before
10.3
Special characters for identifier
Special characters for identifier
In former versions of GX IEC Developer it was not possible to have identifier names which include special characters like e.g. ‘ä’, ‘ö’, ‘ü’. This was not possible due to the IEC naming convention.
GX IEC Developer does now support the usage of special characters.
When the option "Allow special characters for identifier names" in the Options-General dialogue is checked, you can use special characters for identifier names.
Fig. 10-23:
Options - General
The following list shows all newly supported valid characters:
Valid characters: ‘ä’, ‘Ä’, ‘ö’, ‘Ö’, ‘ü’, ‘Ü’, ‘ß’, ‘_’, ‘å’, ‘Å’
The usage of these characters is valid for the following identifier and all functionalities where these identifiers are used (e.g. Variable selection dialogue):
쎲 Library names
쎲 Task names
쎲 DUT names and DUT component names
쎲 Global and local variable names
쎲 POU names (PRG, FUN, FB)
쎲 Network label names
쎲 SFC Transition names
쎲 SFC Action names
쎲 SFC Step names
쎲 SFC Jump label names
The character ‘_’ (underscore) was already allowed in older versions of GX IEC Developer.
Due to the restrictions by the IEC naming convention it was not allowed to use a double underscore character at the beginning of an identifier (e.g. “__TestVar”). Additionally there was a restriction for the usage of the underscore character as the last character of an identifier (e.g.
“TestVar_”). These restrictions can now be disabled by the user.
GX IEC Developer Reference Manual 10 – 19
Special characters for identifier Working with Projects of Version 6.11 and before
NOTES
These identifiers can be used in every program editor:
쎲 LD
쎲 FBD
쎲 IL
쎲 MELSEC-IL
쎲 SFC
쎲 ST
The usage of numbers for the first character for identifier names is not possible.
Identifiers including special characters should only be used in the same way as they were listed in the local header or GVL (upper/lower case).
Otherwise the compiler will show an error message after compiling.
10 – 20
MITSUBISHI ELECTRIC
Working with Projects of Version 6.11 and before Compatibility
10.4
10.4.1
Compatibility
File based compatibility with former versions
쎲 GX IEC Developer 7.03 can open project databases (*.pro file) of MM+ 2.1, 2.30a, 2.31,
2.31a, 2.32, 2.40, 2.40a, 2.50, 3.00, GX IEC Developer 4.00, 5.00, 5.01, 5.02, 6.00, 6.01,
6.10, 6.11, 7.00, 7.01 and 7.02, but these versions can not open GX IEC Developer 7.03
project databases.
Exception: GX IEC Developer 7.03 can not open project databases (*.pro file) of MM+ 2.1,
2.30a, 2.31, 2.31a, 2.32, 2.40, 2.40a, 2.50 and 3.00 with Microsoft Windows
약
XP and
Microsoft Windows Vista
약
.
쎲 GX IEC Developer 7.03 can not open project databases (*.pro file) of MM+ 2.41 and vice versa.
쎲 GX IEC Developer 7.03 can import projects, which have been exported (*.asc file) by
MM+ 2.1, 2.30a, 2.31, 2.31a, 2.32, 2.40, 2.40a, 2.41, 2.50, 3.00, GX IEC Developer 4.00,
5.00, 5.01, 5.02, 6.00, 6.01, 6.10, 6.11, 7.00, 7.01 and 7.02, but these versions cannot import *.asc exports of GX IEC Developer 7.03.
쎲 GX IEC Developer 7.03 can open library files (*.lib file) of GX IEC Developer 4.00, 5.00,
6 . 0 0 , 6 . 1 0 , 6 . 1 1 , 7 . 0 0 , 7 . 0 1 a n d 7 . 0 2 , bu t t h e s e ve r s i o n s c a n n o t o p e n
GX IEC Developer 7.03 library files.
10.4.2
NOTE
PLC project based compatibility with former versions
It is possible, that the generated code of GX IEC Developer 7.03 is different to the generated code of a former version of GX IEC Developer. This could result in the following facts:
쎲 An online change can fail, if the project was not downloaded with GX IEC Developer 7.03.
쎲 The functionality to verify the generated code with the program on the PLC can show differences.
The reason for the differences are internal changes in the code generator which result from the implementation of new features in GX IEC Developer 7.03.
Please also see section 2.9.1, Code Generation.
GX IEC Developer Reference Manual 10 – 21
Compatibility
10.4.3
Working with Projects of Version 6.11 and before
Compatibility with other programming software for MELSEC PLCs:
쎲 GX IEC Developer 7.03 can import MELSEC MEDOC/DOS print files (*.tmp) of the versions 1.64b/c, 2.20 and 2.30.
쎲 GX IEC Developer 7.03 generally can not upload parameters and programs from Q and
QnA/S CPUs, which are generated by GX Developer or GPPQ.
쎲 GX IEC Developer 7.03 can upload only programs from Q and QnA/S CPUs which are generated according to the limitations of GX IEC Developer 7.03 compared to the Q and
QnA/S features (only one program file MAIN.QPG).
쎲 GX IEC Developer 7.03 can upload programs from A CPUs which are generated with
GX Developer or GPPA.
쎲 GX IEC Developer 7.03 can not open project databases from GX Developer, GPPQ or
GPPA.
There is currently no direct possibility to exchange projects between GX IEC Developer 7.03
and GX Developer, GPPQ or GPPA.
10 – 22
MITSUBISHI ELECTRIC
Support of other Applications
11
GX Configurator-DP Support
Support of other Applications
11.1
GX Configurator-DP Support
GX IEC Developer supports the configuration of Profibus Modules. A entry called Module
Configuration is implemented in the Parameters section of the Navigator.
Fig. 11-1:
Project Navigator
The module configuration invokes a dialogue with a list of all configured modules, which are currently available. This information is initially copied from the I/O settings in the PLC parameter configuration. Furthermore it is possible to change the module name. In this case, the I/O settings in the PLC parameter are updated.
For all intelligent function modules a configuration editor can be called by Configure module.
Fig. 11-2:
Module Configuration
Configure module: Opens the corresponding module configuration program (only for
Profibus and intelligent function modules).
GX IEC Developer Reference Manual 11 – 1
GX Configurator-DP Support Support of other Applications
NOTE
쎲 Profibus modules
Profibus modules are identified by the module name and the module type intelli.. Valid module names for Profibus modules are PB92D (for QJ71PB92D or A(1S)J71PB92D),
PB93D (for QJ71PB93D) and FX3U-64DP-M (for FX3U-64DP-M). In case of Profibus
Modules, each module can be assigned to a Profibus configuration by either selecting an existing configuration path or by creating a new configuration. By clicking on
Configure module, the optional application GX Configurator-DP will be called for a more comfortable configuration of the selected Profibus module.
쎲 Intelligent function modules:
If the module type is intelli. and the module name does not match the Profibus description, Configure module calls the intelligent function utilities.
For all other modules, the button Configure module is disabled.
At the first time GX Configurator-DP is called from the dialogue, the user will be prompted to specify the location of the application.
11 – 2
MITSUBISHI ELECTRIC
Support of other Applications
11.2
FX Configurator-EN Support
FX Configurator-EN Support
With the introduction of the new Ethernet unit (FX3U-ENET), GX IEC Developer is now able to communicate with the FX3U via Ethernet. The parameters of the new Ethernet unit are not be part of the PLC parameter, they are stored in the Ethernet unit.
An external application, FX Configurator-EN was introduced to set the parameters and diagnose the FX3U-ENET module.
Open the Module Configuration implemented in the Parameters section of the Navigator.
Fig. 11-3:
Project Navigator in case of a FX3U CPU
For the FX3U eight module positions are available. For each position the type and name of the module can be selected. If the selected module in a row is either a Profibus module or a
Ethernet module, for each of which a Configurator is available, the field to specify or browse for the path of the configuration file will be enabled.
Fig. 11-4:
Module Configuration for a FX3U CPU
The button Configure module… will be enabled, if ...
쎲 FX3U-ENET is selected in the active row and FX Configurator-EN (optional) is installed.
Clicking on Configure module will start the FX Configurator-EN.
쎲 FX3U-64DP-M is selected in the active row and GX Configurator-DP (optional) is installed.
Clicking on Configure module will start the GX Configurator-DP.
At the first time GX Configurator-DP is called from the GX IEC Developer, the user will be prompted to specify the location of this application’s executive file to be able to start the application.
GX IEC Developer Reference Manual 11 – 3
FX Configurator-EN Support Support of other Applications
11 – 4
MITSUBISHI ELECTRIC
Glossary
A Glossary
Absolute address
A variable’s absolute address references a fixed memory location in the CPU or a physical input or output. This absolute address can be assigned using either IEC syntax (IEC address) or MITSUBISHI syntax (MITSUBISHI address). The user must only assign absolute addresses for the global variables. The program assigns suitable memory locations for the local variables automatically.
Absolute Label
Absolute labels are the addresses of specific pointers in the PLC program (e.g. P20). When
PLC programs are uploaded to GX IEC Developer absolute labels are assigned as jump instruction destinations. Every program section identified by a pointer in the original PLC program is loaded in a separate MELSEC network. You can also use absolute labels
(Syntax: P_20) when you assign your own names to networks.
Accumulator
The accumulator is a result handling facility used in IEC Instruction List. You may be familiar with it from other high-level programming languages. The result of every operation performed is written to the accumulator directly after execution. The accumulator thus always contains the result of the last instruction programmed. This means that you do not have to program any input conditions (execution conditions) for the operations, as execution is always dependent on the contents of the accumulator.
Action
An action is allocated to every step in an SFC sequence. These actions can be Boolean output variables or PLC programs.
Action Pool
When you write a POU in Sequential Function Chart language the action pool is displayed in the Project Navigator window as an entry in that POU. The Action Pool contains all the actions belonging to the program organisation unit.
Actual parameters
Functions and function blocks have two kinds of parameters: Formal parameters and actual parameters. The formal parameters are the variables used when you create a function or a function block. The actual parameters are the variables or values passed to the function or function block instance when they are used in another program organisation unit.
’Adapted’ MELSEC instructions
‘Adapted’ MELSEC instructions are MITSUBISHI ELECTRIC instructions with a special modified nomenclature (e.g. BMULTI_M, PLUS_M, FLOAT_MD) for use in the IEC editor.
They always have the suffix _M for ‘MELSEC’ or _MD for ‘MELSEC Dedicated instruction’.
All the ‘adapted’ MELSEC instructions are stored in the Manufacturer Library. These instructions can only be used in the IEC editor
Array
Arrays are derived data types, consisting of fields of one kind of variable. You can define arrays with up to three dimensions.
AutoConnect mode
The Autoconnect mode is a special editing mode used in the graphical editors
Body
Program organisation units (POUs) always consist of a header and a body. The body contains the actual PLC program code.
GX IEC Developer Reference Manual A – 1
A – 2
Glossary
Class
The class is specified in the declaration table to define the way variables are to be used in the project. The following classes are supported: VAR, VAR_CONSTANT, VAR_INPUT,
VAR_OUTPUT, VAR_IN_OUT, VAR_GLOBAL and VAR_GLOBAL_CONSTANT.
Comment
You can enter and store explanatory comment texts for all objects used in GX IEC
Developer. National characters can be used.
Compiling
When you compile a project GX IEC Developer translates the program into code that can be read and executed directly by the PLC.
Computer link module
One of the several ways of connecting the PLC to your personal computer is with a
MITSUBISHI ELECTRIC computer link module. Computer link modules available from
MITSUBISHI ELECTRIC include the following models: AJ71C21, AJ71UC24, AJ71QC24,
A1SJ71QC24, QJ71C24.
Continue condition
Þ ‘Transition condition’
Controller instruction
PLC programs written in Instruction List language consist of a series of controller instructions. Each controller instruction contains an operator, i.e. the programming instruction, and an operand, i.e. the variable.
CPU interface
You can connect the PLC to your personal computer via the CPU interface, which is located on the PLC unit.
Data type
The data type of a variable defines the number of bits it contains, how they are processed and the variable’s value range. The following data types are available: BOOL, INT, DINT,
WORD, DWORD, TIME, REAL, ARRAY, STRING.
Data Unit Type
The Data Unit Type (DUT) is a structured data type. It contains a collection of variables.
Declaration table
Declaration tables are lists used for managing and declaring both global and local variables.
Device Editor
The device editor allows you to display and edit the contents of the PLC CPU’s bit and word devices (registers). The central element of the device editor is a table that is very similar to a Microsoft Excel worksheet, both in its appearance and in the way it is used.
Dialogue box
A dialogue box is a special kind of window used for handling dialogues with the user. They can contain a number of different elements, including fields for entering data, check boxes or radio buttons for selecting options and messages containing important warnings or information. Dialogue boxes are displayed at many different points in the program, for example when you select menu commands followed by three periods (e.g. Open...).
Download
Transfer process from GX IEC Developer to the PLC
MITSUBISHI ELECTRIC
Glossary
DUT Pool
The DUT Pool is one of the standard entries in the Project Navigator window (DUT_Pool). It contains all the Data Unit Types used in the project.
Edit mode
When you are editing the body of a POU you can choose between Select mode and Edit mode. In Edit mode you can perform actions on selected program elements (e.g. move, overwrite, delete etc).
Editing area
The editing window for working on the body of a POU is divided into two main areas, the network bar and the editing area. The editing area is where you enter the component elements of your program.
Editor
The GX IEC Developer editors are program modules used for writing and editing programs in the supported programming languages. The editors are displayed as separate windows on the screen. GX IEC Developer includes text, graphical, IEC and MELSEC editors.
EN input
In addition to their input and output variables, some function blocks also have a Boolean input (EN = ENable) and a Boolean output (ENO = ENable Out). The status of the ENO output always corresponds to the current status of the EN input.
ENO output
Þ ‘EN input’
Entry Data Monitor
GX IEC Developer supports a variety of different monitoring modes: Program Monitor, Entry
Data Monitor and Header Monitor. In the Entry Data Monitor mode the program displays the status of a user-defined list of variables. The variables in this list can be displayed in any order.
Ethernet card
One of the several ways of connecting the PLC to your personal computer is via an
Ethernet network. To do this, you must then have an Ethernet card in your PC and connect it to the MITSUBISHI ELECTRIC Ethernet module.
Final step
The final step is the last step in an SFC sequence.
Formal parameters
Þ ‘Actual parameters’
Function
The function is a program organisation unit (POU) with the class ‘Function’ (FUN). It can be used in the same way as a normal programming instruction. When they are executed, functions deliver precisely one output variable. Functions do not store any internal status data. This means that all a function’s internal variables are always set to 0. When a function is called with the same input parameters it thus always delivers the same output value.
Function block
The function block is a program organisation unit (POU) with the class ‘Function Block’
(FB). It can be used in the same way as a normal programming instruction. Function blocks deliver one or more output variables when they are executed. All the values of the output variables and the internal variables are stored in the function block following execution. This means that function blocks do not necessarily always deliver the same output values when they are called again with the same input parameters. Function blocks can only be called in the form of instances. Be careful not to confuse these function blocks with the graphical function blocks used in the Function Block and Ladder Diagram language!!
GX IEC Developer Reference Manual A – 3
A – 4
Glossary
Function Block Diagram
Function Block Diagram (FBD) is a programming language. Programming instructions are displayed as graphical blocks which are connected with horizontal and vertical interconnect lines. Be careful not to confuse these graphical function blocks with the Function Block (FB) program organisation units!!
Function blocks in the graphical editors
In the graphical editors most programming instructions are displayed as graphical blocks in the editing screen. These graphical blocks are sometimes referred to as ‘function blocks’.
Be very careful not to confuse these blocks with the Function Block program organisation units!!
Global variable
Global variables have fixed hardware addresses (absolute addresses). They are declared
‘globally’ for the entire project and can be referenced from all function block (FB) and program (PRG) program organisation units. They make it possible to exchange data between the individual program modules that make up the project. The global variables are also included as a standard entry in the Project Navigator window, Global_Vars.
Graphic macro
You can define any selected section of a PLC program as a graphic macro. Macros are a useful construct when you need to use the same piece of code several times at different points in your PLC program. Graphic macros are only supported in the graphical editors.
Graphical editor
The following programming languages use graphical editors, which are used in the same way as a standard graphics drawing program: Ladder Diagram (LD), Function Block
Diagram (FBD) and Sequential Function Chart (SFC).
Header
Program organisation units (POUs) always consist of a header and a body. The header contains the declarations of all the variables used in the POU, which are organised in a declaration table.
Header Monitor
GX IEC Developer supports a variety of different monitoring modes: Program Monitor, Entry
Data Monitor and Header Monitor. Header Monitor mode is fundamentally the same as Entry
Data Monitor mode. However, in addition to the user-defined list of variables the monitor also always displays the variables of the active program organisation unit.
Identifier
The identifier is the name allocated to a variable that serves as its symbolic address.
IEC address
The IEC address assigns a fixed memory location to a global variable. The syntax of IEC addressing is defined in the IEC 61131-3 standard. Examples: %IX0 (input X0) ,
%MW0.450 (data register D450)
.
IEC editor
The IEC editor is used for programming in the IEC 61131-3 programming languages.
IEC function
Þ ‘Programming instructions’
IEC function block
Þ ‘Programming instructions’
IEC Instruction List
GX IEC Developer supports both IEC Instruction List language and MELSEC Instruction List.
In IEC Instruction List the program is written according to the IEC 61131-3 standard, using only the instructions from the IEC standard library. However, if you need to do so you can insert MELSEC networks in programs written in IEC Instruction List.
MITSUBISHI ELECTRIC
Glossary
IEC operator
Þ ‘Programming instructions’
IEC programming instruction
Þ ‘Programming instructions’
Initial step
The initial step is the first step in an SFC sequence.
Initialisation file
MMP703.INI is the ‘initialisation file’ for GX IEC Developer. It is stored in the Windows directory and contains all the parameters necessary for initialising the GX IEC Developer program when it is started.
Input variable
Þ ‘Output variable’
Installation program
The installation program INSTALL.EXE copies the contents of the GX IEC Developer program distribution disks to your hard disk and sets the program up for your hardware configuration.
Instance
An instance is a copy of a function block. Function blocks can only be called in the form of instances. Instances are created by declaring them in the headers of program organisation units, and they are called in the body of the POU. Special programming instructions are provided for calling instances.
It is also possible to create global function block instances. These global instances can be used in different program organisation units.
Instructions
Þ ‘Programming instructions’, ‘Controller instructions’
Instruction List
Instruction List is a programming language. GX IEC Developer supports two Instruction List variants, IEC Instruction List and MELSEC Instruction List. An Instruction List program consists of a list of controller instructions.
Interconnect mode
Interconnect mode is a special editing mode in the Ladder Diagram editor, with functionality similar to a line-drawing tool in a graphics program. In Interconnect mode you connect programming elements by drawing horizontal and vertical lines between them.
Interface card
One of the several ways of connecting the PLC to your personal computer is with the
A7BDE interface card from MITSUBISHI ELECTRIC and a MITSUBISHI network. This is an expansion card which must be installed in your computer. (Not yet supported)
Jump entry point
The jump entry point is the point in an SFC sequence to which a jump is to be performed
(i.e. the jump label).
Jump exit point
The jump exit point is the point in an SFC sequence from which a jump is to be performed
(i.e. the position of the jump instruction).
Jump instruction
Jump instructions are used to execute a branch from the current POU to another network.
In the graphical editors the jump instruction is implemented as a tool. In IEC Instruction List jumps are programmed with the JMP operator.
GX IEC Developer Reference Manual A – 5
A – 6
Glossary
Label
The word ‘Label’ is automatically displayed as a dummy variable when you are programming jump instructions in the graphical editors. It must be overwritten with the designator of the actual jump entry point or destination
(Þ absolute label, network label, system label)
Ladder Diagram
Ladder Diagram is a programming language. The programming elements are contacts
(inputs), coils (outputs) and programming instructions which are displayed as graphical blocks. These elements are connected to make circuits using horizontal and vertical interconnect lines. The circuits always start at the power bar on the left.
Library
There are three types of libraries: Standard Library, Manufacturer Library and User Library.
Local variables
Local variables are only accessible within the program organisation units in which they are declared. They are declared in the POU header.
Macro step
In an SFC sequence a macro step is a step that in turn contains another complete SFC sequence.
Manufacturer Library
The Manufacturer Library (Manufacturer_Lib) contains the ‘adapted’ MELSEC programming instructions, with a special nomenclature for use in the IEC editor
(Þ ‘Programming
Instructions’ in the Appendix E).
MELSEC editor
The MELSEC editor is used for editing MELSEC Instruction Lists and MELSEC networks.
MELSEC Instruction List
GX IEC Developer supports both IEC Instruction List language and MELSEC Instruction
List language. MELSEC Instruction List programs only contain MELSEC networks.
MELSEC network
MELSEC networks are programmed according to the DIN 19239 standard, using only the
‘pure’ MELSEC instructions.
MELSEC programming instructions
Þ ‘Programming instructions’
MELSEC upload
The MELSEC upload procedure loads a program into GX IEC Developer from the PLC unit.
Only the binary data is read in when this process is carried out.
MITSUBISHI address
The MITSUBISHI address is used to assign a fixed memory location to a global variable.
Examples: X0, M1024.
Monitoring mode
GX IEC Developer supports a variety of different monitoring modes: Program Monitor, Entry
Data Monitor and Header Monitor
.
Network
A network is a logically continuous program section within a program organisation unit.
Network bar
The editing window in which you work on the body of a POU is divided into the network bar and the editing area. The network bar is used for making the network label and title assignments.
MITSUBISHI ELECTRIC
Glossary
Network label
The network label is the name assigned to a network. It can be used as the destination address for jump instructions in PLC programs.
Network list
The network list contains all the networks in a program organisation unit, along with their network labels and titles.
Network title
The network title is a brief description of the network. It is optional, and it is not displayed in the network bar.
Null modem cable
Þ ‘RS-232 cable’
Object
GX IEC Developer uses the following objects: The IEC Standard Library (Standard_Lib), the Manufacturer Library (Manufacturer_Lib), the PLC Parameter (PLC_Parameter), the
Task Pool (Task_Pool), the Data Unit Type Pool (DUT_Pool), the Global Variables
(Global_Vars) and the POU Pool (POU_Pool). These objects are all displayed as standard entries in the Project Navigator window.
Object window
Object windows contain the data of selected objects (e.g. the declaration table for the global variables or a task’s table).
Output variable
Function blocks have input and output variables. The input variables give the function block the values it uses to perform its programmed operations. The output variables pass the results of these operations out of the function block.
PLC Parameter
The PLC parameter (PLC_Parameter) is one of the standard entries in the Project
Navigator window. It contains the user-editable parameters of the connected PLC system.
POU Pool
The POU Pool is one of the standard entries displayed in the Project Navigator window
(POU_Pool). It contains all the program organisation units used in the project.
Power bar
In the Ladder Diagram graphical editor all circuits start at the vertical power bar on the left of the editing area. This bar is sometimes also referred to as the rail.
Program
1) Program = An application program (e.g. GX IEC Developer);
2) Program = A PLC program, consisting of a series of programming instructions;
3) Program = A program organisation unit classed as a ‘Program’ (PRG). Program POUs can only be executed in tasks.
Program class
The program class of a POU defines its functionality. You can declare POUs as Programs
(PRG), Function Blocks (FB) or Functions (FUN).
Program group
The Windows Program Manager organises programs in groups called ‘program groups’.
Each group can contain a large number of individual programs (i.e. application programs).
The GX IEC Developer installation program automatically creates a program group for GX
IEC Developer containing the GX IEC Developer program icon.
GX IEC Developer Reference Manual A – 7
A – 8
Glossary
Program Monitor
GX IEC Developer supports a variety of different monitoring modes: Program Monitor, Entry
Data Monitor and Header Monitor. You can activate the Program Monitor mode in all the editors. This monitor displays the values and switching statuses of the variables visible in the current editor window.
Program organisation unit
Program organisation units (POUs) can be regarded as subprograms or program modules.
There are three different POU classes, defined by their functionality: Programs (PRG),
Function Blocks (FB) and Functions (FUN). Every POU consists of a header and a body.
Programming elements
Examples of programming elements in the graphical editors include contacts, function blocks, interconnect lines and variable connections.
Programming instructions
GX IEC Developer supports the following groups of programming instructions: IEC programming instructions, MELSEC programming instructions and user programming instructions (
Þ ‘Programming Instructions’ in the Appendix E).
Programming language
GX IEC Developer supports the following programming languages for writing PLC programs: Instruction List (IL), Ladder Diagram (LD), Function Block Diagram (FBD),
Sequential Function Chart (SFC).
Project
The project is the element at the top of the GX IEC Developer object hierarchy. It is equivalent to a PLC system.
Project name
The project name is actually the name of a subdirectory. This subdirectory contains all the individual files that form the components of a project.
Project Navigator
The Project Navigator is the control centre of GX IEC Developer. It is used to administrate all the objects that go to make up a project. It is displayed on the screen as a separate window, the Project Navigator window.
Project Navigator tree
The entries in the Project Navigator window are arranged using a hierarchical tree structure. Some of the levels can be expanded and collapsed to display or hide further levels of the tree hierarchy.
Project Navigator window
All the objects contained in a project are listed in the Project Navigator window. This window is opened on the left hand side of the screen as soon as you create or open a project. It always contains the following standard entries: Standard_Lib, Manufacturer_Lib,
PLC_Parameter, Task_Pool, DUT_Pool, Global_Vars and POU_Pool.
’Pure’ MELSEC Instructions
The ‘pure’ MELSEC instructions are the original MITSUBISHI MELSEC instructions with the standard nomenclature (e.g. AND=, +, FLOAT). These instructions are only supported in the MELSEC editor (
Þ ‘Programming Instructions’ in the Appendix E).
Return instruction
The Return instruction effects a return from a function block to the point in the program from where the function block was called. In the graphical editors the Return instruction is implemented as a tool. In the IEC Instruction List editor returns are implemented with the
RET operator.
RS-232 cable
An RS-232 cable wired as a null modem cable is required for connecting the personal computer to a computer link module.
MITSUBISHI ELECTRIC
Glossary
Select mode
When you are working in the programming editors you can choose between Select mode and Edit mode. In Select mode the mouse pointer is displayed as an arrow with which you can select the various programming elements.
Sequence
Sequences are written with the Sequential Function Chart language (SFC). An SFC sequence consists of steps, actions, transitions and transition conditions. Both parallel and selective branching are supported in sequences.
Sequential Function Chart Language
Sequential Function Chart is a programming language in which steps are linked together with conditions referred to as continue conditions. The elements of the SFC language are steps, actions, transitions and transition conditions.
SFC sequence
Þ ‘Sequence’
Signal configuration
You can set the following signal configuration parameters for the input and output variables of a function block and the input contacts and output coils used in the Ladder Diagram language: Poll for signal status 0 or 1, set and reset.
Standard Library
The Standard Library (Standard_Lib) contains the standard IEC functions (e.g.
INT_TO_BOOL) and function blocks (e.g. R_TRIG).
Status bar
The status bar displayed at the bottom of the screen shows information on the current status of the project. You can configure the status bar to suit your personal requirements.
Step
Sequences in the SFC language always consist of several steps connected by transitions.
An action is assigned to each step in the sequence.
Step mode
Step mode execution is a debugging aid. In this mode, the program is executed one step at a time. Please note that the connected PLC system must be switched to step run mode when you use this option.
STRING
A STRING data type contains characters.
System Label
The system labels (pointers) are system variables that GX IEC Developer needs for internal management of the project. The number of available system labels depends on the PLC used. One system label is needed for each of the following elements: every instance of a function block, every user-defined function, every event-triggered task, every network label.
Task
A task contains one or more program organisation units of the class ‘Program’ (PRG). The task controls the execution of its component POUs. Tasks can be event-triggered, interval-triggered or priority-triggered.
Task Pool
The Task Pool (Task_Pool) is one of the standard entries in the Project Navigator window. It contains all the tasks defined in the project.
Text editor
The text editor is used for writing and editing Instruction List programs. Its functionality is similar to that of a standard word processor.
GX IEC Developer Reference Manual A – 9
A – 10
Glossary
Toolbar
The toolbar displays icons with which the most-used menu commands can be selected directly by clicking with the mouse.
Transition
Transitions connect steps in SFC language sequences. Each transition is allocated a transition condition, i.e. a continue condition that controls how and when control is passed to the next step in the sequence.
Transition condition
A transition condition is a PLC program. It is executed when the preceding SFC step is completed, and if the condition is satisfied control is passed to the next step in the sequence.
Upload
Transfer process from the PLC to GX IEC Developer
User library
A user library gives you the possibility of creating functions and program segments which can be used on a supra-project basis. The program segments are grouped in a library and can be used in any project. Following updating, changes made to the library can be applied to other projects. A user library can contain all the objects that are also available in a project: Global Variables List, Structured Data Types, Arrays and Program Organisation
Units. You can assign a password to protect the know-how in the library. The name of the user library file has the file extension SUL.
User programming instructions
Programming instructions written by the user.
Þ ‘Programming instructions’.
Variable
Variables can be compared with operands. They contain the values of inputs, outputs or internal memory locations in the PLC. GX IEC Developer makes a distinction between global and local variables. Variables are declared and administered in declaration tables; they are defined with a class, an identifier, an absolute address (global variables only) and a data type.
Wizard
The Wizard is a special aid that can be activated and deactivated by editing the initialisation file MMP703.INI. When the Wizard is activated the program can automatically generate a program organisation unit and a task for you when you create a new project.
MITSUBISHI ELECTRIC
Keyboard Commands
B Keyboard Commands
B.1
GX IEC Developer Menu Keys
GX IEC Developer Menu Keys
Key(s)
¦
¤
Functions
Activate/deactivate the Menu Bar
Activate/deactivate the Menu Bar
¥
A - z
Move through Menu Bar to the right (GX IEC Developer menus and Windows control menu)
Move through Menu Bar to the left (GX IEC Developer menus and Windows control menu)
When Menu Bar or menu activated: Select corresponding menu or menu option/command
(e.g. L for Online
)
Activate highlighted menu or menu option/command
«
£
¢
°
¦
¦©
§°
Move highlight up through menu options
Move highlight down through menu options
Exit menu/selection
Quit GX IEC Developer
(Project - Quit)
Activate Help system
Open Task List (list of all application programs currently running) and select program
Open Windows Start menu
Tab. B-1:
GX IEC Developer menu keys
GX IEC Developer Reference Manual B – 1
Common Keys
B.2
Keyboard Commands
Common Keys
Key(s) Function
¦
¦0
§¦w
¦S
¨¦B
¨¦c
¨¦d
¨¦e
¦u
§n
§n
§o
§o
Show next compile/check error (Window - Show Next Error)
Quit the application (Project - Quit)
Activate the navigator window (Window - Navigator)
Download the current project to the PLC (Project - Transfer - Download to PLC...)
Start, stop or reset the PLC or view the PLC operating status (Online - Start/Stop PLC)
Build the project (Project - Build)
Rebuild the project (Project - Rebuild All)
Setup modem for communication (Online - Modem)
View the system errors (Debug - System Errors)
View the user defined errors (Debug - User Errors)
Create a new project (not LD editor)
Insert a contact (Tools - Network Elements - Contact) (LD editor only)
Open a project (not LD and FBD editor)
Insert an output variable field (Tools - Network Elements - Output Variable) (LD and FBD editor only)
¨§
¨§d
¨°
¨
Open an Entry Data Monitor window (Online - Entry Data Monitor)
Change the program online without stopping the PLC (Project - Online Program Change)
Enable or disable the monitoring mode (Online - Monitoring Mode)
Show previous compile/check error (Window - Show Previous Error)
Tab. B-2:
Common keys
B – 2
MITSUBISHI ELECTRIC
Keyboard Commands
B.3
Project Navigator Keys
Project Navigator Keys
Key(s) Function
¨µ
§C
§v
¨±
µ
¦
¨
¦§
§
§¨
§±
§
¦
§
«
¦«
£
¥
³
¢
¤
·
§+
+
: num. keypad
§-
-
: num. keypad
¦
§Z
§x
Move highlight up through Project Navigator Window
Move highlight down through Project Navigator Window
Scroll window contents to the right
Scroll window contents to the left
Page window contents up one screen
Page window contents down one screen
Display lower tree levels of selected entry (Tools - Expand
)
Hide lower tree levels of selected entry (Tools - Collapse
)
Undo the last action (Edit - Undo)
Undo the last action
Cut selected entry and copy to the clipboard (not available for all entries!) (Edit - Cut
)
Cut selected entry and copy to the clipboard
Copy selected entry to clipboard (not available for all entries!) (Edit - Copy
)
Paste data from the clipboard to highlight position (Edit - Paste
)
Paste data from the clipboard to highlight position
Delete selected entry (not available for all entries!) (Edit - Delete
)
Find the specified text (Edit - Find)
Find the next occurrence of the specified text
Find the previous occurrence of the specified text
Replace specific text with different text (Edit - Replace)
Replace the next occurrence of the specified text
Replace all occurrences of the specified text
Insert copied contents
Start monitoring of the active body (Online - Start Monitoring)
Stop monitoring of the active body (Online - Stop Monitoring)
Modify the variable value (Online - Modify variable value)
Open object window or dialogue box of selected entry (Object - Open
)
Edit the properties of the current object (Object - Information...)
Tab. B-3:
Project Navigator keys
GX IEC Developer Reference Manual B – 3
Project Navigator Keys Keyboard Commands
Key(s)
¦C
¦K
¦N
¨¦A
§P
§Q
§S
§
Function
Check the selected object (Object - Check)
Create a new task (Object - New - Task)
Create a new Program Organisation Unit (Object - New - POU)
Create a new Sequential Function Chart action (Object - New - Action)
Print the active object (Object - Print)
Show the print preview of the active object (Object - Print Preview)
Save the selected object (Object - Save)
Close Project Navigator Window (i.e. close project) (Project- Close
)
Tab. B-3:
Project Navigator keys
B – 4
MITSUBISHI ELECTRIC
Keyboard Commands
B.4
Object Window Keys
Object Window Keys
Key (s)
§©
§
§¨
³
·
§³
§·
¦-
§
§¨t
£
Function
Step through all opened windows
Switch to next window
Switch to previous window
Page window contents one screen up
Page window contents one screen down
Scroll window contents to the left
Scroll window contents to the right
Open the Windows control menu of the active window
¢
¤
¥
«
Close the active window (Object - Close)
Arrange all opened windows side by side (Window - Tile)
1) Move pointer up in window
2) Following selection of Move (Size) in the control menu: Move window up (resize window)
1) Move pointer down in window
2) Following selection of Move (Size) in control menu: Move window down (resize window)
1) Move pointer right in window
2) Following selection of Move (Size) in control menu: Move window right
(resize window)
1) Move pointer left in window
2) Following selection of Move (Size) in control menu: Move window left
(resize window)
1) Storing the new window position or window size
2) In Project Navigator Window: Open the object window or dialogue box of the selected entry
Save object (Object - Save) §s
¦C
§P
¦«
Check object (Object - Check)
Print object (Object - Print)
View object information (Object - Information)
Tab. B-4:
Object window keys
GX IEC Developer Reference Manual B – 5
Dialogue Box Keys
B.5
Keyboard Commands
Dialogue Box Keys
¦
ø
¤¥
£¢
²
¶
´
Key(s)
¦
¦¨
¦
©
¨©
¦A - Z
«
Function
Move to next dialogue box
Move to previous dialogue box
Activate/deactivate control menu button
Activate/deactivate control menu button
Step through options from top to bottom / from left to right
Step through options from bottom to top / from right to left
Execute option (e.g. L for Latch Range)
1) Control menu button selected: Open control menu
2) Option selected: Execute option (often the same as clicking the OK! button)
3) List box: Activate selected element
Close dialogue box (often the same as selecting the Cancel! button)
Close dialogue box (often the same as selecting the Cancel! button)
Step through options
1) Step through options
2) List box: Page list up/down one screen at a time
1) List box: Move to first list element
2) Text box: Move to first character
1) List box: Move to last list element
2) Text box: Move to last character
1) List box: Activate/deactivate list element
2) Activate/deactivate check boxes
Tab. B-5:
Dialogue box keys
B – 6
MITSUBISHI ELECTRIC
Keyboard Commands
B.6
Declaration Table Keys
Declaration Table Keys
Key(s)
¤
¥
£
¢
³
·
²
Function
Move up one line at a time
Move down one line at a time
Move right one cell at a time
Move left one cell at a time
Page window contents up one screen at a time
Page window contents down one screen at a time
¶
1) Move to cell in the first column
2) Editing mode: Move to first character in the cell
1) Move to cell in the last column
2) Editing mode: Move to last character in the cell
Step through all cells from left to right
¦C
§P
§Q
§S
µ
¨§¶
¦¢
´
«
¦«
©
¨©
§²
§¶
¨£
¨¢
¨²
¨¶
¨§²
Step through all cells from right to left
Move highlight to beginning of table
Move highlight to end of table
Extend or reverse continuous selection up one line at a time
Extend or reverse continuous selection down one line at a time
Select current line
Select current line
Select all lines from the first line to the current line
Select all lines from the current line to the last line
Open dialogue box or list box of a selected cell containing an arrow symbol
Activate editing mode in the current cell
Deactivate editing mode in the current cell
Edit the properties of the current object (Object - Information...)
Check the selected object (Object - Check)
Print the active object (Object - Print)
Show the print preview of the active object (Object - Print Preview)
Save the selected object (Object - Save)
1) Delete selected range
2) Editing mode: Delete character to right of cursor (Edit - Delete)
1) Delete selected range
2) Editing mode: Delete character to left of cursor
§x
¨µ
Cut selected range and copy to clipboard (Edit - Cut)
Cut selected entry and copy to the clipboard
Tab. B-6:
Declaration table keys
GX IEC Developer Reference Manual B – 7
Declaration Table Keys Keyboard Commands
Key(s)
§C
§v
¨±
§Z
§±
¨«
Function
Copy selected range to clipboard (Edit - Copy)
Paste data from clipboard to current position (Edit - Paste)
Paste data from the clipboard to highlight position
Undo the last action
Insert copied contents
1) From any cell: Move to first column of the next line
2) From any cell in the last line: Insert a new line
¦
§
¦
¨
¦§
§
§¨
§
¦
¨¦
§+
+
: num. keypad
§-
-
: num. keypad
Undo the last command (not supported for all operations!) (Edit - Undo)
Undo the last Undo command (not supported for all operations!) (Edit - Redo)
Find (Edit - Find)
Find Next (Edit - Find Next)
Find the previous occurrence of the specified text
Replace specific text with different text (Edit - Replace)
Replace the next occurrence of the specified text
Replace all occurrences of the specified text
Start monitoring of the active body (Online - Start Monitoring)
Stop monitoring of the active body (Online - Stop Monitoring)
Monitor the header of the active body (Online - Monitor Header)
First cell in the line is marked by a - sign: Display all lines in the comment column
(Tools - Expand declaration)
First cell in the line is marked by a + sign: Display only one line in the comment column
(Tools - Collapse declaration)
Tab. B-6:
Declaration table keys
B – 8
MITSUBISHI ELECTRIC
Keyboard Commands
B.7
Entry Data Monitor Keys
Entry Data Monitor Keys
Key(s) Function
±
µ
¨
§
¦
§+
+
: num. keypad
§-
-
: num. keypad
Delete rows from the EDM (Edit - Delete Rows)
Insert objects into the EDM (Edit - Insert Objects)
Insert next object into the EDM (Edit - Next Object)
Insert empty row into the EDM (Edit - Insert Row)
Show context menu
Start monitoring of the active body (Online - Start Monitoring)
Stop monitoring of the active body (Online - Stop Monitoring)
First cell in the line is marked by a - sign: Display all lines in the comment column
(Tools - Expand declaration)
First cell in the line is marked by a + sign: Display only one line in the comment column
(Tools - Collapse declaration)
Tab. B-7:
Entry Data Monitor keys
B.8
Show Generated Code Keys
Key(s) Function
Copy the whole editor content to the clipboard (Edit - Copy All)
§±
§C Copy the whole editor content to the clipboard
Tab. B-8:
Show generated code keys
B.9
Show Verify Differences Keys
Key(s) Function
©
¨©
§+
§c
Go to the next difference (Tools - Next Difference)
Go to the previous difference (Tools - Previous Difference)
Open the according body and go to the related position (Tools - Go to Editor)
Copy the whole content of the window to the clipboard in plain text format (Edit - Copy All)
Tab. B-9:
Show verify differences keys
GX IEC Developer Reference Manual B – 9
Device Editor Keys
B.10
Device Editor Keys
Key(s) Function
¨¤
¨¥
§¨£
§¨¢
§¨¤
§¨¥
¨³
¨·
§²
§¶
©
¨©
«
¨«
¨£
¨¢
§¨³
§¨·
¨²
§¥
³
·
§³
§·
²
¶
£
¢
¤
¥
§£
§¢
§¤
Move up one cell
Move down one cell
Move right one cell
Move left one cell
Move to top of current data range
Move to bottom of current data range
Move to right edge of current data range
Move to left edge of current data range
Page up
Page down
Page left
Page right
Select cell in first column of current row
Select cell in last column of current row
Select cell in first column of first row (top left)
Select cell in last column of last row (bottom right)
Step through all cells from left to right
Step through all cells from right to left
Step down through all cells
Step up through all cells
Extend or cancel selection upwards one line at a time
Extend or cancel selection downwards one line at a time
Extend or cancel selection right one cell at a time
Extend or cancel selection left one cell at a time
Extend or cancel selection to top of current data range
Extend or cancel selection to bottom of current data range
Extend or cancel selection to right edge of current data range
Extend or cancel selection to left edge of current data range
Extend or cancel selection up one page
Extend or cancel selection down one page
Extend or cancel selection left one page
Extend or cancel selection right one page
Extend or cancel selection to beginning of current line
Tab. B-10: Device Editor keys
Keyboard Commands
B – 10
MITSUBISHI ELECTRIC
Keyboard Commands
Key(s)
¨¶
§¨²
§¨¶
¨´
§´
§¨´
§A
µ
§x
§C
§v
§±
¨±
¨µ
Function
Extend or cancel selection to end of current line
Extend or cancel selection to first column in first line (top left)
Extend or cancel selection to last column in last line (bottom right)
Select current line
Select current column
Select entire table
Select entire table
Delete selected range
Cut selected range to clipboard
Copy selected range to clipboard
Paste contents of clipboard
Copy selected range to clipboard
Paste contents of clipboard
Cut selected range to clipboard
Activate editing mode for selected cell
Clear contents of selected cell and activate editing mode
§«
ø
«
Terminate editing mode
Abort editing mode
Toggle value of selected bit device between 0 and 1
Tab. B-10: Device Editor keys
Device Editor Keys
GX IEC Developer Reference Manual B – 11
Text Editor Keys (IL, MIL, ST)
B.11
Keyboard Commands
Text Editor Keys (IL, MIL, ST)
Key(s)
¦tE
¦tD
¦N
¨
§
§
¨
£¢¤¥
Function
Activate editing mode (Tools - Edit Network)
Activate Select mode (Tools - End Edit)
Display the New Variable dialogue (Tools - New Variable)
Start the variable tracking (Tools - Tracking - Start Tracking)
Next variable occurrence (Tools - Tracking - Next)
Previous variable occurrence (Tools - Tracking - Previous)
Display a list of available operands (Tools - List Operands) (ST only)
Display a list of available operators (Tools - List Operators) (ST only)
«
´
´
(2x)
1) Select mode: Move cursor/pointer in window
2) Editing mode: Scroll through Instruction List
1) Select mode - Pointer on network bar: Open dialogue box for entry of network labels and titles
2) Editing mode: Select/enter new line
Select mode - pointer on network bar: Open dialogue box for assigning network label and title
1) Select mode - pointer on network bar: Activate network
2) Select mode - cursor/pointer in editing window: Activate editing mode
Pointer on bottom border line of network bar: Change size of network area
´£¢
´¤¥
©
Pointer on column dividing line: Change column width
1) Line without text: Select next column
2) Line with text: Move text to next column
1) Cursor/pointer in first column: Open programming instructions list
2) Cursor/pointer in second column: Open variables list
³
·
§³
§·
²
¶
§²
§¶
¨¤
¨¥
¨£
¨¢
¨§²
Page window contents up one screen
Page window contents down one screen
Scroll window contents to the right
Scroll window contents to the left
Move to first character in the line
Move to last character in the line
Move to beginning of Instruction List
Move to end of Instruction List
Extend or reverse selection to the right one character at a time
Extend or reverse selection to the left one character at a time
Extend or reverse selection up one line at a time
Extend or reverse selection down one line at a time
Select all lines from the first line to the current line
Tab. B-11: Text editor keys (IL, MIL, ST)
B – 12
MITSUBISHI ELECTRIC
Keyboard Commands Text Editor Keys (IL, MIL, ST)
Key(s)
¨§¶
¦«
¦c
§P
§Q
§S
µ
Function
Select all lines from the current line to the last line
Edit the properties of the current object (Object - Information...)
Check the selected object (Object - Check)
Print the active object (Object - Print)
Show the print preview of the active object (Object - Print Preview)
Save the selected object (Object - Save)
1) Delete selected range
2) Delete character to right of cursor (Edit - Delete)
1) Delete selected range
2) Delete character left of cursor
§
§¨
¦
§Z
§
¦A
¦B
§
¨
§
¦
¨¦
§
§x
¨µ
§C
§v
¨±
§±
¦
¨
¦§
§
¨
Cut selected range and copy to clipboard (Edit - Cut)
Cut selected entry and copy to the clipboard
Copy selected range to clipboard (Edit - Copy)
Paste data from clipboard to current position (Edit - Paste)
Paste data from the clipboard to highlight position
Insert copied contents
Find (Edit - Find)
Find Next (Edit - Find Next)
Find the previous occurrence of the specified text
Replace specific text with different text (Edit - Replace)
(Edit - Toggle Bookmark)
(Edit - (Next Bookmark)
(Edit - Previous Bookmark)
Replace the next occurrence of the specified text
Replace all occurrences of the specified text
Undo last command (not supported for all operations!) (Edit - Undo)
Undo the last action
Undo last Undo command (not supported for all operations!) (Edit - Redo)
Insert a new network after the current network (Edit - New Network - After)
Insert new network before the current network (Edit - New Network - Before)
Start monitoring of the active body (Online - Start Monitoring)
Start program monitoring (Online - Start Monitoring - Body) (ST only)
Start program monitoring (Online - Start Monitoring - Split Window) (ST only)
Stop monitoring of the active body (Online - Stop Monitoring)
Monitor the header of the active body (Online - Monitor Header)
Modify the variable value (Online - Modify variable value)
Tab. B-11: Text editor keys (IL, MIL, ST)
GX IEC Developer Reference Manual B – 13
Graphical Editor Keys (FBD, LD)
B.12
Keyboard Commands
Graphical Editor Keys (FBD, LD)
«
´£¢
³
·
§³
§·
´
Key(s)
§A
§t
§B
§M
¨
§
§
£¢¤¥
´
(2x)
´£¤¢¥
´£¤¢¥
¨£¤¢¥
¦«
¦c
§P
§Q
§S
µ
Function
Activate Select mode (Tools - Select Mode)
Activate Interconnect mode (draw lines) (Tools - Interconnect Mode)
Activate the auto connect mode (Tools - Auto Connect)
Select the comment placement mode (Tools - Network Elements - Comment)
Start the variable tracking (Tools - Tracking - Start Tracking)
Next variable occurrence (Tools - Tracking - Next)
Previous variable occurrence (Tools - Tracking - Previous)
Move pointer
1) Pointer on network bar: Open dialogue box for entering network labels and titles
2) Pointer on a contact: Open dialogue box for signal configuration F"Helvetica"P10
Pointer on network bar: Open dialogue box to assign network label and title
Pointer on lower border of network bar: Change size of network area
Page window contents up by one screen
Page window contents down by one screen
Scroll window contents to the right
Scroll window contents to the left
1) Select programming element
2) Select network bar
3) Activate editing mode to overwrite the dummy names Var and Label
1) Editing mode for overwriting dummy variable name Var: Open list of variables
2) Open list of programming instructions
1) Move selected programming element
2) Following selection of Tools - Open Row/Column: Increase row/column spacing
3) Following selection of Tools - Comment: Draw a comment box
4) Interconnect mode: Draw interconnect lines
Select a continuous group of program elements
Select several program elements individually
Edit the properties of the current object (Object - Information...)
Check the selected object (Object - Check)
Print the active object (Object - Print)
Show the print preview of the active object (Object - Print Preview)
Save the selected object (Object - Save)
1) Delete selected range
2) Delete character right of cursor (Edit - Delete)
Delete character left of cursor
§x
¨µ
Cut selected range and copy to clipboard (Edit - Cut)
Cut selected entry and copy to the clipboard
Tab. B-12: Graphical editor keys (FBD, LD)
B – 14
MITSUBISHI ELECTRIC
Keyboard Commands Graphical Editor Keys (FBD, LD)
Key(s) Function
0
6
§r
9
5
8
§w
§u
1
2
§Z
§
3
4
7
§J
§C
§v
¨±
§±
¦
¨
¦§
§
§¨
¦§C
¦
§¨l
§¨µ
¦1
¦2
¦3
¦4
Copy selected range to clipboard (Edit - Copy)
Paste data from clipboard to current position (Edit - Paste)
Paste data from the clipboard to highlight position
Insert copied contents
Find (Edit - Find)
Find Next (Edit - Find Next)
Find the previous occurrence of the specified text
Replace specific text with different text (Edit - Replace)
Replace the next occurrence of the specified text
Replace all occurrences of the specified text
Toggle the signal configuration (Edit - Toggle Signal Configuration)
Undo last command (not supported for all operations!) (Edit - Undo)
Undo the last action
Undo last Undo command (not supported for all operations!) (Edit - Redo)
Insert input contact (Tools - Contact) (LD only)
Insert input contact negation (Tools - Contact Negation) (LD only)
Insert input L-connect contact (Tools - L-Connect Contact) (LD only)
Insert input L-connect contact negation (Tools - L-Connect Contact Negation) (LD only)
Insert output coil (Tools - Network Elements - Coil) (LD only)
Insert jump instruction (Tools - Network Elements - Jump)
Insert return instruction (Tools - Network Elements - Return)
Insert input variable (Tools - Network Elements - Input Variable)
Insert output variable (Tools - Network Elements - Output Variable)
Draw horizontal line segment (Tools - Network Elements - Horizontal Line Segment)
Draw vertical line segment (Tools - Network Elements - Vertical Line Segment)
Insert programming instruction (Function Block) (Tools - Function Block)
Increase horizontal spacing (Tools - Open Row)
Increase vertical spacing (Tools - Open Column)
Insert network label (Tools - Network Elements - Label of the Network)
Delete line mode (Tools - Network Elements - Delete Line Mode)
Insert graphic macro 1 (Tools - Custom 1)
Insert graphic macro 2 (Tools - Custom 2)
Insert graphic macro 3 (Tools - Custom 3)
Insert graphic macro 4 (Tools - Custom 4)
Tab. B-12: Graphical editor keys (FBD, LD)
GX IEC Developer Reference Manual B – 15
Graphical Editor Keys (FBD, LD) Keyboard Commands
Key(s)
¦5
¦N
¦A
¦B
§
¦
¦
¨¦
§
©
Function
Insert graphic macro 5 (Tools - Custom 5)
Display the New Variable dialogue (Tools - New Variable)
Insert new network after the current network (Edit - New Network - After)
Insert new network before the current network (Edit - New Network - Before)
Start monitoring of the active body (Online - Start Monitoring)
Stop monitoring of the active body (Online - Stop Monitoring)
Toggle the selected variable (Online - Toggle variable)
Monitor the header of the active body (Online - Monitor Header)
Modify the variable value (Online - Modify variable value)
¨©
Step through all the variable objects in the current network forwards, selecting them one after another.
Step through all the variable objects in the current network backwards, selecting them one after another.
+
(+: num. keypad)
-
(–: num. keypad)
¨§m
Function block is activated: Increment number of input variables (pins)
(Edit - Increment Pins)
Function block is activated: Decrement number of input variables (pins)
(Edit - Decrement Pins)
Toggle the view mode for the addresses (View Mode - Toggle)
Tab. B-12: Graphical editor keys (FBD, LD)
B – 16
MITSUBISHI ELECTRIC
Keyboard Commands
B.13
Sequential Function Chart Editor Keys
Sequential Function Chart Editor Keys
Key(s)
£¢¤¥
§¥
§¤
§£
§¢
¨¥
¨¤
¨£
¨¢
¨§¥
¨§¤
¨§£
¨§¢
©
¨©
²
¶
§²
§¶
¨²
¨¶
¨§²
¨§¶
«
Function
Move highlight
Highlight on a connection line: Move highlight to the leftmost branch in the row
Highlight on a connection line: Move highlight to the rightmost branch in the row
Move highlight to the next branch above or to the Initial Step
Move highlight to next branch below or to the Final Step
Extend selection to the element to the left of the highlight
Extend the selection to the element to the right of the highlight
Extend the selection up one element
Extend the selection down one element
Highlight on a connection line: Extend the selection to the leftmost element in the row
Highlight on a connection line: Extend the selection to the rightmost element in the row
Extend the selection to the next element above or to the Initial Step
Extend the selection to the next element below or to the Final Step
Move the highlight to the next element
Extend the selection to the next element
Move the highlight to the first column
Move the highlight to the last column
Move the highlight to the beginning of the program
Move the highlight to the end of the program
Select all elements between the current highlight position and the left column
Select all elements between the current highlight position and the right column
Select all elements between the current highlight position and the beginning of the program
Select all elements between the current highlight position and the end of the program
1) Highlight on an unnamed Transition or an unnamed Step: Switch to Editing mode
2) Highlight on a named Step: Open window of associated POU
3) Highlight on a Macro Step: Open Macro Program window
1) Undo all selections
ú
µ
³
·
Delete selected elements
Page window contents up by one screen
Page window contents down by one screen
1) Cursor/pointer in first column: Open programming instructions list
2) Cursor/pointer in second column: Open variables list
§S
¦«
¦c
§P
§Q
¦
§Z
§
§x
Save the selected object (Object - Save)
Edit the properties of the current object (Object - Information...)
Check the selected object (Object - Check)
Print the active object (Object - Print)
Show the print preview of the active object (Object - Print Preview)
Undo last command (not supported for all operations!) (Edit - Undo)
Undo the last action
Undo last Undo command (not supported for all operations!) (Edit - Redo)
Cut selected range and copy to clipboard (Edit - Cut)
Tab. B-13: Sequential Function Chart editor keys
GX IEC Developer Reference Manual B – 17
Sequential Function Chart Editor Keys Keyboard Commands
Key(s)
¨µ
§C
§v
§±
¨±
¦
¨
¦§
§
§¨
§u
§F
§t
§l
§r
¨§l
¨§r
§¨J
§J
¦N
§I
§b
§
¨¦
§
Function
Cut selected entry and copy to the clipboard
Copy selected range to clipboard (Edit - Copy)
Paste data from clipboard to current position (Edit - Paste)
Insert copied contents
Paste data from the clipboard to highlight position
Find (Edit - Find)
Find Next (Edit - Find Next)
Find the previous occurrence of the specified text
Replace specific text with different text (Edit - Replace)
Replace the next occurrence of the specified text
Replace all occurrences of the specified text
Insert Step/Transition unit at the current position (Edit - Insert - Step/Trans Unit)
Insert Step at the current position (Edit - Insert - Step)
Insert Transition at the current position (Edit - Insert - Transition)
Insert left divergence from the current position (Edit - Insert - Left Divergence)
Insert right divergence from the current position (Edit - Insert - Right Divergence)
Insert left convergence to the current position (Edit - Insert - Left Convergence)
Insert right convergence to the current position (Edit - Insert - Right Convergence)
Insert Label (jump destination/entry step) (Edit - Insert - Label)
Insert Jump (jump/exit step) (Edit - Insert - Jump)
Display the New Variable dialogue (Tools - New Variable)
Open (zoom) Step, Transition or Macro Program window (Tools - Zoom Into)
Undo zoom operation (Tools - Zoom Back)
Start monitoring of the active body (Online - Start Monitoring)
Monitor the header of the active body (Online - Monitor Header)
Modify the variable value (Online - Modify variable value)
Tab. B-13: Sequential Function Chart editor keys
B – 18
MITSUBISHI ELECTRIC
Keyboard Commands
B.14
Keys for Checking and Downloading Programs
Keys for Checking and Downloading Programs
Key(s) Function
¨¦C
§¦w
¨§D
¦C
§
¦
¨¦
¨§
ùú
¦s
¨¦E
¦u
Compile project (Project - Rebuild All)
Download project to CPU (Project - Transfer - Medoc -> PLC)
Change program in Online mode operation (Project - Online Program Change)
Check object (Object - Check)
Start program monitoring (Online - Start Monitoring)
Stop program monitoring (Online - Stop Monitoring)
Open monitoring window for variable status of current Header (Online - Monitor Header)
Open Entry Data Monitor (Online - Entry Data Monitor)
Activate Monitoring mode (Online - Monitoring Mode)
Switch PLC CPU to Start or Stop mode (Online - Start/Stop PLC)
Execute program in stop mode, stopping after each step (Debug - Step)
Display contents of system error registers (Debug - System Errors)
Associate error messages to error flags (Debug - User Errors)
Tab. B-14: Keys for checking and downloading programs
GX IEC Developer Reference Manual B – 19
Online Help System Keys
B.15
Keyboard Commands
Online Help System Keys
Key(s)
r
<
>
I s z
¦
©
Function
Activate Help system
Contents button
Search button
Back button
History button
<< button (previous topic)
>> button (next topic)
Activate Menu Bar
¨©
Select one of the icons/buttons on the screen
Step through the icons/buttons clockwise
Select one of the icons/buttons on the screen
Step through the icons/buttons anticlockwise
Select all the icons/buttons on the screen
§©
§«
¨«
¦
Copy the current help topic text to the clipboard
Copy the clipboard contents to the Annotate dialogue box
Close the Help window
Tab. B-15: Online Help System Keys
For more details on using the online Help system select How to use help in the Help menu.
B – 20
MITSUBISHI ELECTRIC
Tools
C
C.1
General Tool Icons
Tools
General Tool Icons
Tool Function
Open an existing project
Menu command
Project - Open
Key(s)
Save an opened project
Print the active object
Shows a print preview of the active object
Cut the selected object to the clipboard
Copy the selected object to the clipboard
Paste object from the clipboard
Undo the last action
Redo the previously undone action
Edit the properties of current selection
Open the cross reference browser
Project - Save
Project - Print
Project - Print Preview
Edit - Cut
Edit - Copy
Edit - Paste
Edit - Undo
Edit - Redo
Object - Information
Project - Browse
Start the check routine for the currently selected object
Build the current project (compile changes)
Rebuild the current project (compile project)
Enable or disable the monitoring mode
Activate Online Change mode
Download the current project to the PLC
Upload the project from the PLC
Object - Check
Project - Build
¦C
¨¦B
Project - Rebuild All
Online - Online-Change
Mode
Project - Transfer -
Download to PLC
Project - Transfer -
Upload from PLC
¨¦C
Online - Monitoring Mode
¨ø
§¦w
Tab. C-1:
General tool icons
§x
§c
§V
¦¥
§¥
¦«
GX IEC Developer Reference Manual C – 1
Instruction List Editor Tool Icons
C.2
Instruction List Editor Tool Icons
Tool Function
Insert a new network before the current network
Insert a new network after the current network
Activate Select mode, End Editing mode
Menu command
Edit - New Network -
Before
Edit - New Network - After
Key(s)
¦B
¦A
Tools - End Edit
Activate Editing mode, End Select mode
Tools - Edit Network
Tab. C-2:
Instruction List Editor Tool Icons
Tools
C – 2
MITSUBISHI ELECTRIC
Tools
C.3
Ladder Diagram and Function Block Diagram Editor Tool Icons
Ladder Diagram and Function Block Diagram Editor
Tool Icons
Tool Function
Insert a new network before the current network
Insert a new network after the current network
Insert Return instruction
Increase vertical spacing
Menu command
Edit - New Network -
Before
Key(s)
¦b
Edit - New Network - After
¦a
Activate Select mode, End Editing mode (toggles with Interconnect mode)
Activate Interconnect mode, Line tool (toggles with Select mode)
Insert input contact
(Ladder Diagram only)
Insert input contact negation
(Ladder Diagram only)
Insert input L-contact
(Ladder Diagram only)
Insert input L-contact negation
(Ladder Diagram only)
Insert vertical line
(Ladder Diagram only)
Insert horizontal line
(Ladder Diagram only)
Insert output coil
(Ladder Diagram only)
Insert programming instruction
(Function Block)
Insert input variable
Insert output variable
Activate Auto Connect mode
Tools - Select Mode
Tools - Network Elements -
Interconnect Mode
Tools - Network Elements -
Contact
Tools - Network Elements -
Contact Negation
Tools - Network Elements -
L-Connection Contact
Tools - Network Elements -
L-Connection Contact
Negation
Tools - Network Elements -
Vertical Line Segment
§a
§T
1
2
3
4
5
Tools - Network Elements -
Horizontal Line Segment
6
Tools - Network Elements -
Coil
7
Tools - Network Elements -
Function block
8
Tools - Network Elements -
Input Variable
9
Tools - Network Elements -
Output Variable
0
Tool - Auto Connect
§b
Insert Jump instruction
Tools - Network Elements -
Jump
§J
Tools - Network Elements -
Return
§r
Tools - Open Row
§u
Increase horizontal spacing
Insert comment
Tools - Open Column
§w
Tools - Network Elements -
Comment
§m
Tab. C-3:
Ladder Diagram and Function Block Diagram editor tool icons
GX IEC Developer Reference Manual C – 3
Sequential Function Chart Editor Tool Icons
C.4
Tools
Sequential Function Chart Editor Tool Icons
Tool Function Menu command
Insert a Step/Transition unit at the current position
Edit - Insert - Step/Trans
Unit
Insert a Step at the current position
Edit - Insert - Step
Insert a Transition at the current position
Insert a left divergence from the current position
Insert a right divergence from the current position
Insert a left convergence to the current position
Insert a right convergence to the current position
Insert a Label (entry step/jump destination)
Edit - Insert - Left
Divergence
Edit - Insert - Right
Divergence
Edit - Insert - Left
Convergence
Edit - Insert - Right
Convergence
Edit - Insert - Label
Insert a Jump (exit step jump instruction)
Edit - Insert - Transition
Edit - Insert - Jump
Key(s)
§u
§F
§T
§l
§r
¨§l
¨§r
§¨j
§j
Open (zoom) a Macro Program window
Tools - Zoom Macro
Open (zoom) the Action Association window for the selected Step
Edit the Step Comment
Tools - Edit Action
Association
Tools - Edit Step Comment
Edit the Transition Condition
Open (zoom) the Body of a Step or Transition
Tools - Edit Transition
Condition
Tools - Zoom Body
Open (zoom) a Step, Transition, or Macro
Program window
Undo zoom operation (i.e. close window)
List all available variables or operands
Tools - Zoom Into
Tools - Zoom Back
Tools - List Operands…
§I
§B
Tab. C-4:
Sequential Function Chart Editor Tool Icons
C – 4
MITSUBISHI ELECTRIC
Tools
C.5
Project Navigator Window Tool Icons
Project Navigator Window Tool Icons
Tool Function
Display lower levels of the Project Navigator tree
Menu command
Tools - Expand
Hide displayed levels of the Project Navigator
Create a new Program Organisation Unit
Create a new Data Unit Type
Tools - Collapse
Object - New - POU
Object - New - DUT
Create a new Task Object - New - Task
Create a new Action (this icon is only enabled when a POU written in Sequential Function Chart language is selected)
Tab. C-5:
Project Navigator Window Tool Icons
Object - New - Action
Key(s)
¦+
¦-
¦n
¦k
¨¦A
GX IEC Developer Reference Manual C – 5
Project Navigator Window Tool Icons Tools
C – 6
MITSUBISHI ELECTRIC
Temporary Files
D Temporary Files
Temporary Files Created when Projects are Compiled
D.1
Temporary Files Created when Projects are Compiled
A number of temporary files are created during compilation. These files are normally deleted when the program is finished; if you don’t want them to be deleted you must start GX IEC
Developer with the
/debug
command line option. To do this, add this option to the GX IEC
Developer command line in the Program Item Properties dialogue box in the Windows
Program Manager:
E.g.:
c:\melsec\gx iec developer\sc.exe
/debug.
쎲 _tskmain.sic
_tskmain.out
_tskmain.bin
Data of all tasks allocated to the MAIN memory range
(stored in a special format)
Data of all tasks allocated to the MAIN memory range
(special MELSEC code)
Data of all tasks allocated to the MAIN memory range
(the compiled code that is downloaded to the controller)
쎲 _tsksub.sic
_tsksub.out
_tsksub.bin
Data of the Task
MELSEC_SUB
(stored in a special format)
, allocated to the SUB memory range
Data of the Task
MELSEC_SUB
(special MELSEC code)
, allocated to the SUB memory range
Data of the Task
MELSEC_SUB
, allocated to the SUB memory range
(the compiled code that is downloaded to the controller)
쎲 POUname.sic
Data of a specific Program Organisation Unit
(stored in a special format)
POU-Name.out
Data of a specific Program Organisation Unit
(special MELSEC code)
POU-Name.bin
Data of a specific Program Organisation Unit
(the compiled code that is downloaded to the controller)
쎲 _end.sic
_end.out
_end.bin
Data of the END instruction (stored in a special format)
Data of the END instruction (special MELSEC code)
Data of the END instruction (the compiled code that is downloaded to the controller)
쎲 main.map
All the data of the program allocated to the MAIN memory range
(compiled structural tree)
쎲 sub.map
All the data of the program allocated to the SUB memory range
(compiled structural tree)
쎲 sfc.map
All the data of the program written in Sequential Function Chart
Language (compiled structural tree)
쎲 sfccode.cod
Data of the Program Organisation Units that were written in Sequential
Function Chart Language (compiled code)
쎲 mmicro.bin
Data of the Program Organisation Units that were written in
Sequential Function Chart Language - MELSEC A-Series
(compiled code)
쎲 build.out, tab.out, rebuild.out, comp.out
Compiling data
GX IEC Developer Reference Manual D – 1
Temporary files Created During Downloads
D.2
Temporary files Created During Downloads
쎲 dwl_sym.asc
쎲 upl_sym.pac
쎲 upl_main.bin
쎲 upl_sub.bin
쎲 fnw_main.dis
쎲 fnw_sub.dis
쎲 fnw_imp.asc
쎲 task_imp.asc
Temporary Files
D – 2
MITSUBISHI ELECTRIC
Programming Instructions
E Programming Instructions
Programming Instructions
IEC Programming
Instructions
IEC Editors
MELSEC
Programming Instructions
User-programmed
Programming Instructions
in the form of
Program Organisation Units
(POUs)
IEC Editors
IEC Operators
(e.g. LD, ST, CAL)
‘Pure’
MELSEC Instructions
MELSEC Editor
(e.g. +, B*)
Functions
(Name of the Function POU)
IEC Functions
(e.g. INT_TO_BOOL, ROR)
‘Adapted’
MELSEC Instructions
IEC Editors
(e.g. PLUS_M, BMULTI_M,
FLOAT_K_P_MD)
Contents of the
Standard
Library
Contents of the
Manufacturer
Library
Function Blocks
(Name of the
Function Block POU)
IEC Function Blocks
(e.g. R_TRIG, F_TRIG)
Fig. E-1:
Programming instructions
Standard Library
The standard library contains all the IEC functions and function blocks. Every available function has a FUN (function) POU, the headers of which you can open and view on the screen.
Manufacturer Library
The Manufacturer Library contains the ‘adapted’ MELSEC instructions, with a nomenclature adapted for use in IEC. Every function has a FUN (function) POU, the headers and bodies of which you can open and view on the screen. With the help of a special tool you can also add your own POUs to the Manufacturer Library. These POUs can be declared as functions (FUN), function blocks (FB) or programs (PRG).
GX IEC Developer Reference Manual E – 1
E – 2
Programming Instructions
MELSEC Instructions
The functionality of the ‘adapted’ and ‘pure’ MELSEC functions is identical. The only difference between the two versions is the way they are written and how they are used in the various editors.
The ‘pure’ MELSEC instructions use the familiar MELSEC nomenclature (e.g. AND=, +,
FLOAT). These instructions can only be used in the MELSEC editor.
Fig. E-2:
This dialogue box is displayed when you are working in the
MELSEC editor. The list contains the ‘pure’ MELSEC instructions
.
The ‘adapted’ MELSEC instructions use a special nomenclature. Their names always end with
_M for MELSEC or _MD for MELSEC Dedicated Instr uctions (e.g. PLUS_M,
FLOAT_K_P_MD). You can use these instructions in the IEC editor.
Fig. E-3:
This dialogue box is displayed when you are working in the IEC editor.
The list of the Manufacturer Library contains the
‘adapted’ MELSEC instructions.
The suffixes _P_MD and _K_MD indicate that the instruction under consideration is executed on a rising edge or with a constant.
MITSUBISHI ELECTRIC
Programming Instructions
MELSEC Instructions
MELSEC Editor
LEDA
LEDC
LEDC
LEDR
FLOAT
(S)
(D)
LEDB
LEDC
LEDC
LEDR
FLOAT
(S)
(D)
LEDA
SUB
(S)
LEDC
LEDR
LEDB
SUB
(S)
LEDC
LEDR
LEDA
DFLOAT
LEDC
LEDC
LEDR
FLOAT
(D)
FLOAT
(D)
(S)
(D)
LEDB
DFLOAT
LEDC
LEDC
LEDR
LEDA
DFLOAT
DXNR
LEDC
LEDR
LEDB
DFLOAT
DXNR
LEDC
LEDR
(S)
(D)
(S)
(D)
(S)
(D)
IEC Editor
FLOAT_MD
FLOAT_P_MD
FLOAT_K_MD
FLOAT_K_P_MD
DFLOAT_MD
DFLOAT_P_MD
DFLOAT_K_MD
DFLOAT_K_P_MD
Tab. E-1:
MELSEC Instructions
Explanation
Normal execution (16 Bit)
Pulse-triggered execution (16 Bit)
Normal execution (16 Bit) Constant used in operand (S)
Pulse-triggered execution (16 Bit) Constant used in operand (S)
Normal execution (32 Bit)
Pulse-triggered execution (32 Bit)
Normal execution (32 Bit) Constant used in operand (S)
Pulse-triggered execution (32 Bit) Constant used in operand (S)
GX IEC Developer Reference Manual E – 3
E – 4
Programming Instructions
Meaning of extensions in the IEC editor
The following table lists the extensions of MELSEC instructions in the IEC editor. The nomenclature is as follows:
쎲 _instruction_
쎲 _instruction
Extension in IEC Editor
_M
_P_M
_MD
_P_MD
_K_MD
_K_P_MD
_E
_S, _STRING
S_, STRING_
_J_M,
_JP_M
_U_M,
_UP_M
Meaning
MELSEC instruction
Pulse triggered execution of MELSEC instruction
Dedicated MELSEC Instruction
Pulse triggered execution of dedicated MELSEC Instruction
Constant used in dedicated MELSEC Instruction
Constant used in and pulse triggered execution of dedicated MELSEC Instruction
Floating point number operands are used
String operands are used
Network number of HOST station is used in operand
Head I/O address of network in HOST station is used in operand
Tab. E-2:
Meaning of extensions in the IEC editor
EN input and ENO output
In the Standard Library, most of the programming instructions are displayed in two similar forms.
The only difference between these programming instructions is the suffix _E. This suffix specifies functions and function blocks which have an EN input and an ENO output (
The functions in the Manufacturer Library do not have this suffix although they all have an EN input and an ENO output.
MITSUBISHI ELECTRIC
Programming Instructions IEC Programming Instructions
E.1
IEC Programming Instructions
Instruction
)
ABS
ABS_E
ADD
ADD_E
ADD_TIME
ADD_TIME_E
AND
AND_E
BCD_TO_DINT
BCD_TO_DINT_E
BCD_TO_INT
BCD_TO_INT_E
BOOL_TO_DINT
BOOL_TO_DINT_E
BOOL_TO_DWORD
BOOL_TO_DWORD_E
BOOL_TO_INT
BOOL_TO_INT_E
BOOL_TO_TIME
BOOL_TO_TIME_E
BOOL_TO_WORD
BOOL_TO_WORD_E
CAL C, N
DINT_TO_BCD
DINT_TO_BCD_E
DINT_TO_BOOL
DINT_TO_BOOL_E
DINT_TO_DWORD
DINT_TO_DWORD_E
DINT_TO_INT
DINT_TO_INT_E
DINT_TO_REAL
DINT_TO_REAL_E
Modifier
(
N, (
Description
IEC Instruction List operator
Right parenthesis
The right parenthesis (close parenthesis) is used to evaluate a deferred operation. The beginning of the deferred operation is marked with a left parenthesis
Absolute value
Writes the input variable data to the output variable with a positive sign.
Addition
Addition
Logical AND operation
Converts BCD format to binary format (DINT)
Converts BCD format to binary format(INT)
Converts BOOL data type to DINT data type
Converts BOOL data type to DWORD data type
Converts BOOL data type to INT data type
Converts BOOL data type to TIME data type
Converts BOOL data type to WORD data type 1
IEC Instruction List operator
Calls a Function Block instance.
In the Instruction List language Function Block instances are called with the CAL operator. The operator must be followed by the instance name, which in turn must be followed by the argument list in parentheses, containing the actual parameters to be passed to the formal parameters.
Converts binary format (DINT) to BCD format
-
1
Converts DINT data type to BOOL data type
Converts DINT data type to DWORD data type
Converts DINT data type to INT data type
Converts DINT data type to REAL data type
Tab. E-3:
IEC programming instructions
1
1
No. of input variables
e.g.
AND(
Data types
Input variables
MUL(
1 INT, DINT
Output variables
NE(. The left parenthesis is added to the operator itself as a modifier.
INT, DINT n
(2 – 28)
2 n
(2 – 28)
1
1
1
(IN1) –
(INn):
INT, DINT,
Constant
(IN1), (IN2):
TIME
WORD,
DWORD,
BOOL,
Constant
BOOL,
WORD,
DWORD
BOOL,
WORD,
DWORD
BOOL
INT, DINT
TIME
WORD,
DWORD,
BOOL
DINT
INT
DINT
1 BOOL DWORD
1
1
1
1
BOOL
BOOL
BOOL
-
DINT,
Constant
DINT
DINT
DINT
DINT
INT
TIME
WORD
-
BOOL,
WORD,
DWORD
BOOL
DWORD
INT
REAL
GX IEC Developer Reference Manual E – 5
IEC Programming Instructions Programming Instructions
Instruction
DINT_TO_TIME
DINT_TO_TIME_E
DINT_TO_WORD
DINT_TO_WORD_E
DIV
DIV_E
(
DIV_TIME
DIV_TIME_E
DWORD_TO_BOOL
DWORD_TO_BOOL_E
DWORD_TO_DINT
DWORD_TO_DINT_E
DWORD_TO_INT
DWORD_TO_INT_E
DWORD_TO_TIME
DWORD_TO_TIME_E
DWORD_TO_WORD
DWORD_TO_WORD
_E
EQ
EQ_E
(
F_TRIG
F_TRIG_E
GE
GE_E
GT
GT_E
Modifier
Description
(
(
Converts DINT data type to TIME data type
Converts DINT data type to WORD data type
Division; (IN1) : (IN2)
Division; (IN1) : (IN2)
Converts DWORD data type to BOOL data type
Converts DWORD data type to DINT data type
Converts DWORD data type to INT data type
Converts DWORD data type to TIME data type
Converts DWORD data type to WORD data type
INT_TO_BCD
INT_TO_BCD_E
INT_TO_BOOL
INT_TO_BOOL_E
INT_TO_DINT
INT_TO_DINT_E
INT_TO_DWORD
INT_TO_DWORD_E
INT_TO_REAL
INT_TO_REAL_E
INT_TO_TIME
INT_TO_TIME_E
Converts INT data type to BOOL data type
Converts INT data type to DINT data type
Converts INT data type to DWORD data type
Converts INT data type to REAL data type
Converts INT data type to TIME data type
Tab. E-3:
IEC programming instructions
1
1
1
1
1
1
1
2
1
1
2
No. of input variables
1
Data types
Input variables
DINT
Output variables
TIME
DINT WORD
(IN1), (IN2):
INT, DINT,
Constant
(IN1), (IN2):
TIME
DWORD
INT, DINT
TIME
BOOL
DWORD
DWORD
DWORD
DWORD
DINT
INT
TIME
WORD
Equality (=);
[(IN1 = IN2)] & [(IN2) = (IN3)] & ... & [(INn-1) = (INn)];
If the comparison result is true, then 1 to output.
If the comparison result is false, then 0 to output.
n
(2 – 28)
1
(IN1) –
(INn): INT,
DINT,
WORD,
DWORD,
BOOL,
Constant
(CLK):
BOOL
Function Block;
Falling edge detector; the current signal status on the output variable (Q) changes in response to a falling edge on the input variable (CLK).
Greater than/equals sequential comparison (>=);
[(IN1) >= (IN2)] & [(IN2) >= (IN3)] & ... & [(INn-1) >=
(INn)];
If the comparison result is true, then 1 to output.
If the comparison result is false, then 0 to output.
Greater than sequential comparison (>)
[(IN1) > (IN2)] & [(IN2) > (IN3)] & ... & [(INn-1) > (INn)]
If the comparison result is true, then 1 to output.
If the comparison result is false, then 0 to output.
Converts binary format (INT) to BCD format n
(2 – 28) n
(2 – 28)
1
(IN1) –
(INn): INT,
DINT,
WORD,
DWORD,
BOOL,
Constant
(IN1) –
(INn): INT,
DINT,
WORD,
DWORD,
BOOL,
Constant
INT
INT
INT
INT
INT
INT
BOOL
Q: BOOL
BOOL
BOOL
BOOL,
WORD,
DWORD
BOOL
DINT
DWORD
REAL
TIME
E – 6
MITSUBISHI ELECTRIC
Programming Instructions IEC Programming Instructions
Instruction Modifier
Description
No. of input variables
1
Data types
Input variables
INT
Output variables
WORD INT_TO_WORD
INT_TO_WORD_E
JMP
Converts INT data type to WORD data type
LD
LE
LE_E
LIMIT
LIMIT_E
LT
LT_E
MAX
MAX_E
MIN
MIN_E
C, N
N
(
(
IEC Instruction List operator
Jump to network label
Performs a jump from one program section to a label in another network. You must specify the network label name after the operator.
IEC Instruction List operator
Load
Loads the value of the specified operand into the accumulator.
Less than/equals sequential comparison (<=)
[(IN1) <= (IN2)] & [(IN2) <= (IN3)] & ... & [(INn-1) <=
(Inn)]
If the comparison result is true, then 1 to output.
If the comparison result is false, then 0 to output.
Value limitation
If (IN) > (MX), then (MX) to output.
If (IN) < (MN), then (MN) to output.
If (MN) < (IN) > (MX), then (IN) to output
Less than sequential comparison (<)
[(IN1)< (IN2)] & [(IN2)< (IN3)] & ... & [(INn-1) < (INn)]
If the comparison result is true, then 1 to output.
If the comparison result is false, then 0 to output.
Select maximum value
The largest value in (IN1) – (INn) as written to the output.
Select minimum value
The smallest value in (IN1) – (INn) is written to the output.
-
1 n
(2 – 28)
3 n
(2 – 28) n
(2 - 28) n
(2 - 28)
2
1
BOOL,
WORD,
DWORD,
INT, DINT
(IN1) –
(INn): INT,
DINT,
WORD,
DWORD,
BOOL,
Constant
(MN), (IN),
(MX): INT,
DINT,
WORD,
DWORD,
BOOL
(IN1) –
(INn): INT,
DINT,
WORD,
DWORD,
BOOL
(IN1) –
(INn): INT,
DINT,
WORD,
DWORD,
BOOL
(IN1) –
(INn): INT,
DINT,
WORD,
DWORD,
BOOL
(IN1), (IN2):
INT, DINT
INT, DINT
-
BOOL
INT, DINT,
WORD,
DWORD,
BOOL
BOOL
INT, DINT,
WORD,
DWORD,
BOOL
INT, DINT,
WORD,
DWORD,
BOOL
INT
INT, DINT
MOD
MOD_E
MOVE
MOVE_E
MUL
MUL_E
Remainder (IN1) - [(IN1) : (IN2)] x (IN2)
Move
MUL_TIME
MUL_TIME_E
MUX
MUX_E
( Multiplication
Multiplication
Multiplexer
Writes the data of the input variable between (INO) and
(Inn) to the output. The input variable is specified in (K).
n
(2 – 28)
2 n
(2 – 28)
(IN1) –
(INn): INT,
DINT
(IN1), (IN2):
TIME
(K): INT,
DINT; (IN0)
– (INn):
INT, DINT,
WORD,
DWORD,
BOOL
INT, DINT
TIME
INT, DINT,
WORD,
DWORD,
BOOL
Tab. E-3:
IEC programming instructions
GX IEC Developer Reference Manual E – 7
IEC Programming Instructions Programming Instructions
Instruction
NE
NE_E
NOT
NOT_E
OR
OR_E
R
R_TRIG
R_TRIG_E
REAL_TO_DINT
REAL_TO_DINT_E
REAL_TO_INT
REAL_TO_INT_E
RET
ROL
ROL_E
ROR
ROR_E
S
SEL
SEL_E
SHL
SHL_E
SHR
SHR_E
Modifier
(
N, (
C, N
Description
Not equal (<>)
[(IN1) <> (IN2)]
If the comparison result is true, then 1 to output.
If the comparison result is false, then 0 to output.
Negation
Logical OR operation
IEC Instruction List operator
Reset
Resets the BOOL variable to 0. This operation is only performed if the value in the accumulator is 1.
Function Block
Rising edge detector
The status of the output variable (Q) is changed in accordance with the presence of a rising edge on the input variable (CLK).
Converts REAL data type to DINT data type
Converts REAL data type to INT data type
1
IEC Instruction List operator
Return from a Function Block
Executes a return from a Function Block to the program in which the Function Block instance was called.
Rotate left
Rotates the data of the input variable (IN) to the left by
(N) bits. No bits are lost in this process.
-
2
Rotate right
Rotates the data of the input variable (IN) to the right by (N) bits. No bits are lost in this process.
IEC Instruction List operator
Set
Sets the value of the BOOL variable to 1. This operation is only performed when the value in the accumulator is 1.
Binary selection
When (G) = 0 then (IN0) to output.
When (G) = 1 then (IN1) to output.
Left shift
Shifts the data of the input variable (IN) to the left by
(N) bits. The upper (N) bits of (IN) are lost in this process.
Right shift
Shifts the data of the input variable (IN) to the right by
(N) bits. The lower (N) bits of (IN) are lost in this process.
No. of input variables
2
1 n
(2 – 28)
1
Data types
Input variables
(IN1), (IN2):
INT, DINT,
WORD,
DWORD,
BOOL
WORD,
DWORD,
BOOL
WORD,
DWORD,
BOOL
BOOL
Output variables
BOOL
WORD,
DWORD,
BOOL
WORD,
DWORD,
BOOL
-
2
1
3
2
2
(CLK):
BOOL
REAL
REAL
-
(Q): BOOL
DINT
INT
-
(IN): BOOL,
WORD,
DWORD;
(N):
Constant
(IN): BOOL,
WORD,
DWORD;
(N):
Constant
BOOL
WORD,
DWORD,
BOOL
WORD,
DWORD,
BOOL
-
(G): BOOL;
(IN0), (IN1):
INT, DINT,
WORD,
DWORD,
BOOL
(IN): BOOL,
WORD,
DWORD;
(N):
Constant
(IN): BOOL,
WORD,
DWORD;
(N):
Constant
INT, DINT,
WORD,
DWORD,
BOOL
WORD,
DWORD,
BOOL
WORD,
DWORD,
BOOL
Tab. E-3:
IEC programming instructions
E – 8
MITSUBISHI ELECTRIC
Programming Instructions
Instruction
ST
SUB
SUB_E
SUB_TIME
SUB_TIME_E
TIME_TO_BOOL
TIME_TO_BOOL_E
TIME_TO_DINT
TIME_TO_DINT_E
TIME_TO_DWORD
TIME_TO_DWORD_E
TIME_TO_INT
TIME_TO_INT_E
TIME_TO_WORD
TIME_TO_WORD_E
WORD_TO_BOOL
WORD_TO_BOOL_E
WORD_TO_DINT
WORD_TO_DINT_E
WORD_TO_DWORD
WORD_TO_DWORD
_E
WORD_TO_INT
WORD_TO_INT_E
WORD_TO_TIME
WORD_TO_TIME_E
XOR
XOR_E
(
N, (
Modifier
Description
N IEC Instruction List operator
Store
Stores the value of the specified operand to the accumulator.
Subtraction; (IN1) - (IN2)
Subtraction; (IN1) - (IN2)
Converts TIME data type to BOOL data type
Converts TIME data type to DINT data type
Converts TIME data type to DWORD data type
Converts TIME data type to INT data type
Converts TIME data type to WORD data type
Converts WORD data type to BOOL data type
Converts WORD data type to DINT data type
Converts WORD data type to DWORD data type
Converts WORD data type to INT data type
Converts WORD data type to TIME data type
Logical exclusive OR operation
Tab. E-3:
IEC programming instructions
IEC Programming Instructions
1
1
1
1
1
1
No. of input variables
1
2
2
1
Data types
Input variables
BOOL,
WORD,
DWORD,
INT, DINT
(IN1), (IN2):
INT, DINT
(IN1), (IN2):
TIME
TIME
Output variables
-
INT, DINT
TIME
BOOL
1 TIME DINT
TIME
TIME
TIME
WORD
WORD
WORD
DWORD
INT
WORD
BOOL
DINT
DWORD
1
1
WORD
WORD n
(2 – 28)
WORD,
DWORD,
BOOL
INT
TIME
WORD,
DWORD,
BOOL
GX IEC Developer Reference Manual E – 9
IEC – MELSEC Programming Instructions
E.2
IEC – MELSEC
The following tables list the most common IEC programming instructions with their corresponding MELSEC programming instructions. For a complete overview of instructions refer to the programming manuals for the A/Q and FX series.
E.2.1
Addition
Programming instruction Description
IEC
IEC Editor
ADD
ADD_E
Modifier: (
MELSEC
IEC Editor
ADD_M
DADD_M
PLUS_M
DPLUS_M
PLUS_3_M
DPLUS_3_M
ADD_MD
MELSEC
MELSEC
Editor
ADD
DADD
+
D+
BPLUS_M
DBPLUS_M
BPLUS_3_M
DBPLUS_3_M
SADD_MD
ADD
(with LED* !)
햲
B+
DB+
SADD
(with LED* !)
햲
Addition of numerical data/with EN input and ENO output
Addition of numerical data (16/32 bit)
Addition of numerical data (16/32 bit)
Addition of numerical data (16/32 bit)
Addition of floating-point numbers
BCD addition (16/32 bit)
BCD addition (16/32 bit)
3
2
2
3
Concatenation of two ASCII strings 2
No. of input variables
Series
n
(2 – 28)
3
2
Notes
Q, QnA, A,
FX, FX0
The IEC functions with input variables of the INT (DINT) data type correspond to the MELSEC functions with 16 (32) bit data.
The number of input variables is fixed using the MELSEC functions and variable using the IEC functions (min. 2, max. 28).
Q, QnA, FX
All the MELSEC functions have an
EN input and an ENO output.
Q, QnA, A
Q, QnA, A
Q, QnA,
AnA
For floating-point numbers only
Q, QnA, A For BCD data only
Q, QnA, A
Q, QnA,
AnA
WARNING!
No addition!
Tab. E-4:
Addition
IEC
ADD_E with 3 input variables of data type INT
ADD_E with 2 input variables of data type
DINT
Advantage: Enables addition of up to 28 input variables.
Þ
Þ
햲
Dedicated instructions with LEDA/B
MELSEC in the IEC Editor
ADD_M for the FX series
PLUS_3_M for the A series
DPLUS_M for the A series
E – 10
MITSUBISHI ELECTRIC
Programming Instructions IEC – MELSEC
E.2.2
Subtraction
Programming instruction Description
IEC
IEC Editor
SUB
SUB_E
Modifier: (
MELSEC
IEC Editor
SUB_3_M
DSUB_3_M
MINUS_M
DMINUS_M
MINUS_3_M
DMINUS_3_M
SUB_MD
BMINUS_M
DBMINUS_M
BMINUS_3_M
DBMINUS_3_
M
햳
MELSEC
MELSEC
Editor
SUB
DSUB
-
D-
SUB
(with LED* !)
햲
B-
DB-
SUB
Subtraction of numerical data/with
EN input and ENO output
Subtraction of numerical data
(16/32 bit)
Subtraction of numerical data
(16/32 bit)
Subtraction of numerical data
(16/32 bit)
Subtraction of floating-point numbers
BCD subtraction
(16/32 bit)
BCD subtraction
(16/32 bit)
3
2
3
2
2
3
Execute a microcomputer program 1
No. of input variables
Series
2
Notes
Q, QnA, A,
FX, FX0
The IEC functions with input variables of the INT (DINT) data type correspond to the MELSEC functions with 16 (32) bit data.
All the MELSEC functions have an
EN input and an ENO output.
FX
Q, QnA, A
Q, QnA, A
Q, QnA,
AnA
For floating-point numbers only
Q, QnA, A For BCD data only
Q, QnA, A
Q, QnA, A
WARNING!
No subtraction!
Tab. E-5:
Subtraction
IEC
SUB_E with input variables of data type INT
SUB_E with input variables of data type DINT
Þ
Þ
MELSEC in the IEC Editor
MINUS_M for the A series
DMINUS_M for the A series
햲
Dedicated instructions with LEDA/B
햳
These instructions are not supported by the IEC editor.
GX IEC Developer Reference Manual E – 11
IEC – MELSEC Programming Instructions
E.2.3
Multiplication
Programming instruction
IEC
IEC Editor
MUL
MUL_E
Modifier: (
MELSEC
IEC Editor
MUL_M
DMUL_M
MULTI_M
DMULTI_M
MULTI_3_M
DMULTI_3_M
MUL_MD
BMULTI_M
DBMULTI_M
BMULTI_3_M
DBMULTI_3_M
MELSEC
MELSEC
Editor
MUL
DMUL
*
D*
MUL
(with LED* !)
햲
B*
DB*
Description
Multiplication of numerical data/with EN input and ENO output
Multiplication of numerical data
(16/32 bit)
Multiplication of numerical data
(16/32 bit)
Multiplication of numerical data
(16/32 bit)
Multiplication of floating-point numbers
BCD multiplication (16/32 bit)
BCD multiplication (16/32 bit)
No. of input variables
Series
n
(2 – 28)
Notes
Q, QnA, A,
FX, FX0
The IEC functions with input variables of the INT (DINT) data type correspond to the MELSEC functions with 16 (32) bit data.
The number of input variables is fixed using the MELSEC functions and variable using the IEC functions (min. 2, max. 28).
3 FX
All the MELSEC functions have an
EN input and an ENO output.
2 A
3
2
2
3
Q, QnA, A
Q, QnA,
AnA
For floating-point numbers only
Q, QnA, A For BCD data only
A
Tab. E-6:
Multiplication
IEC
MUL_E with 3 input variables of data type INT
MUL_E with 2 input variables of data type DINT
Advantage: Enables multiplication of up to
28 input variables.
Þ
Þ
햲
Dedicated instructions with LEDA/B
MELSEC in the IEC Editor
MUL_M for the FX series
MULTI_3_M for the A series
DMULTI_M for the A series
E – 12
MITSUBISHI ELECTRIC
Programming Instructions IEC – MELSEC
E.2.4
Division
Programming instruction Description
IEC
IEC Editor
DIV
DIV_E
Modifier: (
MELSEC
IEC Editor
DIV_M
DDIV_M
DIVID_M
DDIVID_M
DIVID_3_M
DDIVID_3_M
DIV_MD
MELSEC
MELSEC
Editor
DIV
DDIV
/
D/
BDIVID_M
DBDIVID_M
BDIVID_3_M
DBDIVID_3_M
DIV
(with LED* !)
햲
B/
DB/
Division of numerical data/with EN input and ENO output
Division of numerical data
(16/32 bit)
Division of numerical data
(16/32 bit)
Division of numerical data
(16/32 bit)
Division of floating-point numbers
BCD division (16/32 bit)
BCD division (16/32 bit)
Tab. E-7:
Division
No. of input variables
Series
2
Notes
Q, QnA, A,
FX, FX0
The IEC functions with input variables of the INT (DINT) data type correspond to the MELSEC functions with 16 (32) bit data.
All the MELSEC functions have an
EN input and an ENO output.
3
2
3
2
2
3
FX
A
Q, QnA, A
Q, QnA,
AnA
For floating-point numbers only
Q, QnA, A For BCD data only
A
IEC
DIV_E with input variables of data type INT
Þ
DIV_E with input variables of data type DINT
햲
Dedicated instructions with LEDA/B
Þ
MELSEC in the IEC Editor
DIVID_M for the A series
DDIVID_M for the A series
GX IEC Developer Reference Manual E – 13
IEC – MELSEC Programming Instructions
E.2.5
Move
Programming instruction
IEC
IEC Editor
MOVE
MOVE_E
MELSEC
IEC Editor
MOV_M
DMOV_M
BMOV_M
SMOV_M
SMOV_MD
MELSEC
MELSEC
Editor
MOV
DMOV
BMOV
SMOV
SMOV
(with LED* !)
햲
Shift move
Character string move
Tab. E-8:
Move
Description
Moves numerical data/ with EN input and ENO output
Moves numerical data (16/32 bit)
Block data move
BMOVR_MD BMOVR
(with LED* !)
햲
FMOV_M FMOV
Moves the data from one block to another block with the extension file registers
Fill move
2
2
No. of input variables
Series
1
Notes
Q, QnA, A,
FX, FX0
The IEC functions with input variables of the INT (DINT) data type correspond to the MELSEC functions with 16 (32) bit data.
All the MELSEC functions have an
EN input and an ENO output.
1
2
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
AnA
Special move operations
4
1
Q, QnA, A,
FX, FX0
FX
Q, QnA,
AnA
IEC
MOVE_E with 1 input variable of data type INT
Þ
MOVE_E with 1 input variable of data type DINT
햲
Dedicated instructions with LEDA/B
Þ
MELSEC in the IEC Editor
MOV_M for the A and FX series
DMOV_M for the A and FX series
E – 14
MITSUBISHI ELECTRIC
Programming Instructions IEC – MELSEC
E.2.6
BCD – BIN conversion
Programming instruction Description
IEC
IEC Editor
INT_TO_BCD
INT_TO_BCD_E
DINT_TO_BCD
DINT_TO_BCD_E
BCD_TO_INT
BCD_TO_INT_E
BCD_TO_DINT
BCD_TO_DINT_E
Conversion of binary format (INT) to
BCD format/with EN input and ENO output
Conversion of binary format (DINT) to
BCD format/with EN input and ENO output
Conversion of BCD format to binary format (INT)/with EN input and ENO output
Conversion of BCD format to binary format (DINT)/with EN input and ENO output
1
1
MELSEC
IEC Editor
BCD_M
DBCD_M
BIN_M
DBIN_M
BINDA_MD
DBINDA_MD
BINHA_MD
DBINHA_MD
DABIN_MD
DDABIN_MD
HABIN_MD
DHABIN_MD
BCDDA_MD
DBCDDA_MD
DABCD_MD
DDABCD_MD
MELSEC
MELSEC
Editor
BCD
DBCD
BIN
DBIN
BINDA
DBINDA
(with LED* !)
햲
BINHA
DBINHA
(with LED* !)
햲
DABIN
DDABIN
(with LED* !)
햲
HABIN
DHABIN
(with LED* !)
햲
BCDDA
DBCDDA
(with LED* !)
햲
DABCD
DDABCD
(with LED* !)
햲
Conversion of binary format to BCD format (16/32 bit)
Conversion of BCD format to binary format (16/32 bit)
Conversion of binary data (16/32 bit) to an ASCII string (decimal)
1
1
1
Conversion of binary data (16/32 bit) to an ASCII string (hexadecimal)
1
Conversion of an ASCII string (decimal) to binary data (16/32 bit)
1
Conversion of an ASCII string
(hexadecimal) to binary data (16/32 bit)
1
Conversion of BCD data (16/32 bit) to an ASCII string (decimal)
1
Conversion of an ASCII string (decimal) to BCD coded data (16/32 bit)
1
No. of input variables
Series
1
1
Notes
Q, QnA, A,
FX, FX0
The IEC functions with input variables of the INT (DINT) data type correspond to the MELSEC functions with 16 (32) bit data.
Q, QnA, A,
FX, FX0
All the MELSEC functions have an EN input and an ENO output.
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
Q, QnA,
AnA
For ASCII strings
Q, QnA,
AnA
Q, QnA,
AnA
Q, QnA,
AnA
Q, QnA,
AnA
Q, QnA,
AnA
Tab. E-9:
BCD – BIN conversion
IEC
INT_TO_BCD_E
BCD_TO_INT_E
햲
Dedicated instructions with LEDA/B
Þ
Þ
MELSEC in the IEC Editor
BCD_M for the A and FX series
BIN_M for the A and FX series
GX IEC Developer Reference Manual E – 15
IEC – MELSEC Programming Instructions
E.2.7
Logic Operations
Programming instruction Description No. of input variables
Series Notes
IEC
IEC Editor
AND
AND_E
Modifier: N, C
OR
OR_E
Modifier: N, C
XOR
XOR_E
Modifier: N, C
MELSEC
IEC Editor
WAND_M
DAND_M
WAND_3_M
DAND_3_M
MELSEC
MELSEC
Editor
WAND
DAND
WOR_M
DOR_M
WOR_3_M
DOR_3_M
WXOR_M
DXOR_M
WXOR_3_M
DXOR_3_M
WOR
DOR
WXOR
DXOR
Logical AND operation/with EN input and ENO output
Logical OR operation/with EN input and ENO output
Logical exclusive OR operation/with EN input and ENO output n
(2 – 28) n
(2 – 28) n
(2 – 28)
Q, QnA,
A, FX,
FX0
Q, QnA,
A, FX,
FX0
Q, QnA,
A, FX,
FX0
Logical AND operation (16/32 bit)
Logical AND operation (16/32 bit)
Logical OR operation (16/32 bit)
Logical OR operation (16/32 bit)
Logical exclusive OR operation (16/32 bit)
Logical exclusive OR operation (16/32 bit)
WXNR_M
DXNR_M
WXNR_3_M
DXNR_3_M
햳
WXNR
AND
Logical exclusive NOR operation
(16/32 bit)
Logical exclusive NOR operation
(16/32 bit)
AND operation with poll for signal status 1
2
3
1
햳
햳
ANI
OR
AND operation with poll for signal status 0
OR operation with poll for signal status 0
1
1
햳
햳
ORI
AND**
ANDD**
OR**
ORD**
OR operation with poll for signal status 0
AND comparison operations
(16/32 bit)
1
2
OR comparison operations (16/32 bit) 2
햳
Tab. E-10: Logic Operations
2
3
2
3
2
3
The IEC functions with input variables of the INT (DINT) data type correspond to the MELSEC functions with 16 (32) bit data.
The number of input variables is fixed using the MELSEC functions and variable using the IEC functions
(min. 2, max. 28).
All the MELSEC functions have an
EN input and an ENO output.
Q, QnA, A
Q, QnA,
A, FX,
FX0
Q, QnA, A
A, FX,
FX0
Q, QnA, A
Q, QnA,
A, FX,
FX0
Q, QnA, A Exclusive NOR is not available as an
IEC function.
Q, QnA, A
Q, QnA,
A, FX,
FX0
A, FX,
FX0
Input contacts
Q, QnA,
A, FX,
FX0
A, FX,
FX0
Q, QnA, A Comparison
(
Þ Comparisons table)
Q, QnA, A
IEC
AND_E with 3 input variables of data type WORD
AND_E with 2 input variables of data type DWORD
Advantage: Enables operation performance of up to 28 input variables.
Þ
Þ
MELSEC in the IEC Editor
WAND_3_M for the A and FX series
DAND_M for the A and FX series
햳
These instructions are not supported by the IEC editor.
E – 16
MITSUBISHI ELECTRIC
Programming Instructions IEC – MELSEC
E.2.8
Start of an Operation and Output of a Result
Programming instruction
IEC
IEC Editor
LD
Modifier: N
ST
Modifier: N
MELSEC
IEC Editor
햳
햳
햳
햳
MELSEC
MELSEC
Editor
LD
LDI
LD**
LDD**
OUT
Description
IEC Instruction List operator
Load specified value/variables into the accumulator
IEC Instruction List operator
Load specified value/variables into the accumulator
Start of a logic operation with poll for signal status 1 (input contact)
Start of a logic operation with poll for signal status 0 (input contact)
Start of comparison operations
(16/32 bit)
Output, Assignment of a logic operation result (output coil)
1
1
1
1
No. of input variables
Series
1
1
Notes
Q, QnA, A,
FX, FX0
The IEC function LD does not function as an input condition. This function loads a value into the accumulator.
Q, QnA, A,
FX, FX0
The MELSEC LD and LDI functions are used as the input condition for the subsequent operations.
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
Q, QnA, A
The IEC functions LD and ST are operators that are only used in the
IEC Instruction List language
(
Q, QnA, A,
FX, FX0
Tab. E-11: Start of an Operation and Output of a Result
햳
These instructions are not supported by the IEC editor.
GX IEC Developer Reference Manual E – 17
IEC – MELSEC Programming Instructions
E.2.9
Comparisons
Programming instruction Description
No. of input variables
IEC
IEC-Editor
GT
GT_E
GE
GT_E
EQ
EQ_E
LE
LE_E
LT
LT_E
NE
NE_E
MELSEC
IEC-Editor
햳
햳
햳
햳
햳
햳
햳
햳
햳
햳
햳
햳
햳
햳
햳
햳
햳
햳
MELSEC
MELSEC-
Editor
AND>=
ANDD>=
AND=
ANDD=
AND<=
ANDD<=
AND<
ANDD<
AND<>
ANDD<>
OR>
ORD>
OR>=
ORD>=
OR=
ORD=
OR<=
ORD<=
OR<
ORD<
OR<>
ORD<>
LD>
LDD>
LD>=
LDD>=
LD=
LDD=
LD<=
LDD<=
LD<
LDD<
LD<>
LDD<>
AND>
ANDD>
Decreasing sequence >/with EN input and ENO output
Monotonic sequence >=/with EN input and ENO output
Equality =/with EN input and ENO output
Monotonic sequence <=/with EN input and ENO output
Increasing sequence </with EN input and ENO output
Inequality <>/with EN input and ENO output n
(2 – 28) n
(2 – 28) n
(2 – 28) n
(2 – 28) n
(2 – 28)
2
Beginning of a comparison,
Sequential comparison > (16/32 bit)
Beginning of a comparison,
Sequential comparison >= (16/32 bit)
Beginning of a comparison,
Equality = (16/32 bit)
Beginning of a comparison,
Sequential comparison <= (16/32 bit)
Beginning of a comparison,
Sequential comparison < (16/32 bit)
Beginning of a comparison,
Inequality <> (16/32 bit)
AND comparison,
Sequential comparison > (16/32 bit)
AND comparison,
Sequential comparison >= (16/32 bit)
AND comparison,
Equality = (16/32 bit)
AND comparison,
Sequential comparison <= (16/32 bit)
AND comparison,
Sequential comparison < (16/32 bit)
AND comparison,
Inequality <> (16/32 bit)
OR comparison,
Sequential comparison > (16/32 bit)
OR comparison,
Sequential comparison >= (16/32 bit)
OR comparison,
Equality = (16/32 bit)
OR comparison,
Sequential comparison <= (16/32 bit)
OR comparison,
Sequential comparison < (16/32 bit)
OR comparison,
Inequality <> (16/32 bit)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Tab. E-12: Start of an Operation and Output of a Result
Series Notes
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
The number of input variables is fixed using the MELSEC functions and variable using the IEC functions
(min. 2, max. 28).
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
E – 18
MITSUBISHI ELECTRIC
Programming Instructions
IEC
GT_E with 2 input variables of data type INT
GT_E with 2 input variables of data type DINT
Advantage: Enables comparison of up to 28 input variables.
Þ
Þ
MELSEC in the IEC Editor
LD_GT_M for the A series
LDD_GT_M for the A series
햳
These instructions are not supported by the IEC editor
.
IEC – MELSEC
GX IEC Developer Reference Manual E – 19
IEC – MELSEC Programming Instructions
E.2.10
Shift
Programming instruction
IEC
IEC Editor
SHL
SHL_E
SHR
SHR_E
Description
Left shift
Shifts the data of the input variable (IN1) to the left by (N) bits. The upper (N) bits of (IN1) are lost in this process/with EN input and ENO output
Right shift
Shifts the data of the input variable (IN1) to the right by (N) bits. The upper (N) bits of (IN1) are lost in this process /with EN input and ENO output
2
No. of input variables
Series
2
Notes
The upper bits are lost in the IEC functions.
Q, QnA, A,
FX, FX0
With the MELSEC functions the upper bits are also lost
Q, QnA, A,
FX, FX0
MELSEC
IEC Editor
SFL_M
SFR_M
SFTL_M
SFTR_M
WSFL_M
WSFR_M
SFT_M
BSFL_M
BSFR_M
DSFL_M
DSFR_M
MELSEC
MELSEC
Editor
SFL
SFR
SFTL
SFTR
WSFL
WSFR
SFT
BSFL
BSFR
DSFL
DSFR
Shift a 16-bit data word to the left by (n) bits (Carry Flag)
Shift a 16-bit data word to the right by (n) bits (Carry Flag)
2
2
Shift bit devices (n) bits to the left 4
Shift bit devices (n) bits to the right
4
4 Shift word devices (n) places to the left
Shift word devices (n) places to the right
Shift bit devices by 1 bit
4
1
2 Shift bit devices one place to the left (Carry Flag)
Shift bit devices one place to the right (Carry Flag)
2
Shift word devices one place to the left
Shift word devices one place to the right
2
2
Q, QnA, A
Q, QnA, A
FX
FX
FX
FX
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Q, QnA, A
Tab. E-13: Shift
IEC
SHL_E with input variables of data type WORD
SHR_E with input variables of data type WORD
Þ
Þ
MELSEC in the IEC Editor
SFL_M for the A series (Difference: Carry
Flag)
SFR_M for the A series (Difference: Carry
Flag)
E – 20
MITSUBISHI ELECTRIC
Programming Instructions IEC – MELSEC
E.2.11
Rotation
Programming instruction Description
IEC
IEC Editor
ROL
ROL_E
ROR
ROR_E
Rotate left
The data in (IN) are rotated left by
(N) bits; no bits are lost/with EN input and ENO output
Rotate right
The data in (IN) are rotated right by
(N) bits; no bits are lost /with EN input and ENO output
2
2
MELSEC
IEC Editor
ROL_M
DROL_M
ROR_M
DROR_M
ROL_2_M
DROL_2_M
ROR_2_M
DROR_2_M
RCL_2_M
DRCL_2_M
RCR_2_M
DRCR_2_M
RCL_M
DRCL_M
RCR_M
DRCR_M
Tab. E-14: Rotation
MELSEC
MELSEC
Editor
RCL
DRCL
RCR
DRCR
RCL
DRCL
RCR
DRCR
ROL
DROL
ROR
DROR
ROL
DROL
ROR
DROR
Rotate left in A0 and A1 (16/32 bit) 1
Rotate right in A0 and A1 (16/32 bit) 1
Rotate left (16/32 bit) 2
Rotate right (16/32 bit) 2
Rotate left with Carry Flag
(16/32 bit)
Rotate right with Carry Flag
(16/32 bit)
Rotate left in A0 and A1 with Carry
Flag (16/32 bit)
Rotate right in A0 and A1 with Carry
Flag (16/32 bit)
2
2
1
1
No. of input variables
Series
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
Notes
None of the bits are lost.
Q, QnA, A
Q, QnA, A
FX
FX
Special rotation
FX
FX
Q, QnA, A
Q, QnA, A
IEC
ROL_E with input variables of data type WORD
ROR_E with input variables of data type DWORD
Þ
Þ
MELSEC in the IEC Editor
ROL_M for the A series
(Difference: Carry Flag,
Fixed device A0)
DROR_M for the A series
(Difference: Carry Flag,
Fixed devices A0 and A1)
GX IEC Developer Reference Manual E – 21
IEC – MELSEC Programming Instructions
E.2.12
Set and Reset Operations
Programming instruction
IEC
IEC Editor
S
R
Description
IEC Instruction List operator
Set
Sets the value of the BOOL variable to 1. This operation is only executed when the value in the accumulator is
1.
IEC Instruction List operator
Reset
Sets the value of the BOOL variable to 0. This operation is only executed when the value in the accumulator is
1.
1
1
No. of input variables
Series Notes
Q, QnA, A,
FX, FX0
In the IEC functions the contents of the accumulator have an effect on the execution of the functions
(
Q, QnA, A,
FX, FX0
MELSEC
IEC Editor
SET_M
MELSEC
MELSEC
Editor
SET Device set operation 1
RST_M RST Device reset operation 1
Q, QnA, A,
FX, FX0
Q, QnA, A,
FX, FX0
Q, QnA, A Special set and reset operations BSET_M
BRST_M
DSET_MD
DRST_MD
BSET
BRST
Used to set individual bits in word devices
Used to reset individual bits in word devices
Direct set DSET
(with LED!)
햲
DRST
(with LED!)
햲
ZRST
Direct reset
Reset device zones
2
2
1
1
2 ZRST_M
Tab. E-15: Set and Reset Operations
Q, QnA, A
Q, QnA,
AnA
Q, QnA,
AnA
FX
햲
Dedicated instructions with LEDA/B
E – 22
MITSUBISHI ELECTRIC
Programming Instructions IEC – MELSEC
E.2.13
Rising/Falling Edge
Programming instruction
IEC
IEC Editor
R_TRIG
R_TRIG_E
F_TRIG
F_TRIG_E
Description
Function block
Rising edge detect
The current signal status of the output variable (Q) changes on the rising edge on the input variable (CLK)/with
EN input and ENO output
Function block
Falling edge detect
The current signal status of the output variable (Q) changes on the falling edge on the input variable (CLK)/with
EN input and ENO output
1
1
No. of input variables
Series Notes
Q, QnA,
A, FX
R_TRIG/E_R_TRIG and
F_TRIG/E_F_TRIG are Function
Blocks. This means that you must create instances of them before you can use them in your program
(
Q, QnA,
A, FX
MELSEC
IEC Editor
MELSEC
MELSEC
Editor
PLS PLS_M
PLF_M PLF
Generates a single pulse on rising edge; the current signal status changes on a rising edge.
Generates a single pulse on a falling edge; the current signal status changes on a falling edge.
1
1
Tab. E-16: Rising/Falling Edge
Q, QnA,
A, FX,
FX0
Q, QnA,
A, FX,
FX0
IEC
R_TRIG_E
F_TRIG_E
Þ
Þ
MELSEC in the IEC Editor
PLS_M
PLF_M
GX IEC Developer Reference Manual E – 23
IEC – MELSEC
E.2.14
Negation
Programming instruction Description
IEC
IEC Editor
NOT
NOT_E
MELSEC
IEC Editor
CML_M
DCML_M
NEG_M
DNEG_M
MELSEC
MELSEC
Editor
CML
DCML
NEG
DNEG
Tab. E-17: Negation
Negation/with EN input and ENO output
1
Data negation (16/32 bit)
Negation of the individual bits
Data negation (16/32 bit)
Formation of the two’s complement
2
0
No. of input variables
Series Notes
Q, QnA,
A, FX,
FX0
Q, QnA,
A, FX,
FX0
Q, QnA,
A, FX,
FX0
IEC
NOT_E with an input variable of data type WORD
NOT_E with an input variable of data type DWORD
Þ
Þ
MELSEC in the IEC Editor
CML_M
DCML_M
Programming Instructions
E – 24
MITSUBISHI ELECTRIC
Programming Instructions IEC – MELSEC
E.2.15
Jumps/Program Branching
Programming instruction Description
IEC
IEC Editor
JMP
Modifiers: N, C
IEC Instruction List operator.
Jump to a network label.
You can execute a jump to another network within a program section.
Specify the name (label) of the network after the operator.
MELSEC
IEC Editor
햳
햳
햳
MELSEC
MELSEC
Editor
JMP
CJ
Unconditional jump within a program 1
Conditional jump within a program 1
SCJ Conditional jump within a program, executed in the next program cycle
Tab. E-18: Jumps/Program Branching
1
No. of input variables
Series
0
Notes
Q, QnA, A,
FX, FX0
The IEC JMP function is normally executed without any input condition.
You must use the modifier to program a conditional jump.
Network labels are used as jump destinations.
(
Q, QnA, A
Q, QnA, A,
FX
Q, QnA, A
Meaning of the modifiers for the jump function JMP:
JMP (Jump):
The jump is always executed unconditionally.
JMPC (Jump Conditional):
The jump is only executed when the value in the accumulator is 1
.
JMPCN (Jump Conditional Not):
The jump is only executed when the value in the accumulator is 0.
햳
These instructions are not supported by the IEC editor.
GX IEC Developer Reference Manual E – 25
IEC – MELSEC Programming Instructions
E.2.16
Calling Subprograms and Function Blocks
Programming instruction Description
IEC
IEC Editor
CAL
Modifiers: C, N
RET
Modifiers: C, N
IEC Instruction List operator
Call to a Function Block instance.
In Instruction List the instances of
Function Blocks can only be called via the CAL operator. Specify the instance name after the operator, then pass the actual parameters to the formal parameters.
IEC Instruction List operator
Return from a Function Block.
From a Function Block, you can return to the program from which the
Function Block instance was called.
0
0
MELSEC
IEC Editor
햳
햳
햳
MELSEC
MELSEC
Editor
CALL
SRET
RET
Call a subprogram
End/return from a subprogram
Terminate Step Ladder
Tab. E-19: Calling Subprograms and Function Blocks
1
0
0
0
No. of input variables
Series
A, FX
Q, QnA, A,
FX
Q, QnA, A,
FX
FX
Q, QnA, A
FX
Notes
The IEC functions are used for jumps to and returns from Function Blocks.
The MELSEC functions are used for jumps to and returns from the normal subroutines/subprograms in the PLC sequence program.
햳
These instructions are not supported by the IEC editor.
E – 26
MITSUBISHI ELECTRIC
Programming Instructions
E.2.17
Exclusive Q Series Instructions
Programming instruction Description
MELSEC
IEC Editor
MELSEC
MELSEC
Editor
UNIRD_M
UNIRDP_M
TRACE_M
TRACER_M
UNIRD
UNIRDP
TRACE
TRACER
Read the module information stored in the area starting from the designated I/O No. and store it in the area starting from the designated device.
Store trace data set at a peripheral device to trace file in IC memory card by the designated number when
SM800, SM801, and SM802 turn
ON.
Reset the data set by the TRACE instruction.
SP.FWRITE_M
SP.FWRITE
Write data to a designated file.
SP.FREAD_M
SP.FREAD
Read data from a designated file.
3
0
0
PLOADP_M PLOADP Transfer the program stored in a memory card or standard memory card (other than drive 0) to drive 0 and place the program in stand-by status.
PUNLOADP_M PUNLOADP Delete the stand-by program stored in standard memory (drive 0).
PSWAPP_M PSWAPP
RBMOV_M
RBMOVP_M
RBMOV
RBMOVP
2
Delete stand-by program stored in designated standard memory (drive
0). Then the program stored in a memory card or standard memory
(other than drive 0) is transferred to drive 0 and placed in stand-by status.
Block data move
3
3
6
6
2
No. of input variables
Series
Q
Q
Q
Q
Q
Q
Q
Q
Q
Tab. E-20: Exclusive Q Series Instructions
Notes
IEC – MELSEC
GX IEC Developer Reference Manual E – 27
IEC – MELSEC Programming Instructions
E – 28
MITSUBISHI ELECTRIC
Menu structure
F Menu structure
The following pages show the menu structure of GX IEC Developer. The menu structure and the available commands are context-sensitive, changing depending on which CPU series you are using and what you are currently doing in the program.
This is marked by the following footnotes:
햲 no Remote I/O
햳 no FX0 / FX0S
햴 no A- and FX-series
햵 no FX-series
햶 no Q00(J)/Q01
햷 only FX-series
햸 only Q00(J)/Q01
햹 only A- and FX-series
햺 only FX3U
햻 only Q- and QnA-series
햽 only Q-series
햾 only Q-series except Q25SS
햿 only QnPRH
헀 only with MXFastLinx PAK code
헁 only available in the IEC Instruction List (Body IL)
헂 only available in Ladder Diagram
헃 only available in Global Variable List
헄 only available in SFC
헅 only available in Ladder Diagram and Function Block Diagram
헆 only QnU
GX IEC Developer Reference Manual F – 1
F – 2
Project
all windows
New…
Open...
Close
Save
Save as…
Other
씰
Rename…
Copy…
Import…
Export…
Export to Eprom
햹
Update Libraries
햲
Verify
Change PLC Type…
햲
Build
햲
Rebuild All
햲
Transfer
Online Program Change
Browse…
햲 햾
햲 햳
Make Cross Reference
햲
FastLinx
씰
MXChange Database Actions
씰
씰
Upload from PLC…
Download to PLC…
Verify
Online verify
햿
Download Symbolic Information
햲 햻
Copy Program Memory to Flash ROM
햲 햽
Copy Program Cache to
Program Memory
헆
MXChange Project Actions
씰
FastLinx New
햲 헀
FastLinx Open
햲 헀
New
햲 헀
Open
햲 헀
Save as
햲 헀
Delete
햲 헀
Compact
햲 헀
Change Password
햲 헀
Close
햲 헀
Load from MXChange
햲 헀
Show Changes
햲 헀
Global Adjust
햲 헀
Delete
햲 헀
Printer Setup…
Print Options…
Print Preview…
Print…
Change Security Level…
Change Passwords…
Recent Files
Quit
Menu structure
MITSUBISHI ELECTRIC
Menu structure
Object
in Navigator
New
Open
햲
Close
햲
Save
햲
Rename…
햲
Comment…
Information…
Check
Print…
Print Preview…
Import…
Export…
씰
POU…
햲
Task…
햲
Action…
햲
Data Unit Type…
햲
Object
in Body IL, MELSEC IL, LD, FBD, ST, SFC
Close
Save
Comment…
Information…
Check
Print…
Print Preview…
Open Header
Object
in Declaration editors
Close
Save
Comment…
Information…
Check
Print…
Print Preview…
Open Body
GX IEC Developer Reference Manual F – 3
Menu structure
F – 4
Edit
in Navigator
Cut
햲
Copy
Paste
Delete
햲
Find…
햲
Replace…
햲
Update Library
햲
User Library
씰
Install/Create…
햲
Deinstall
햲
Modify…
Open…
햲
햲
Close
햲
Save
햲
Delete
햲
Change Password…
햲
Edit
in Body IL, MELSEC IL
Undo
Redo
Cut
Copy
Paste
Delete
Find…
Replace…
New Network
씰
Top
Before
After
Bottom
MELSEC Before
헁
Edit
in Body LD, FBD
Undo
Redo
Cut
Copy
Paste
Delete
Find…
Replace…
New Network
Increment Pins
Decrement Pins
Signal Configuration…
Toggle Signal Config…
씰
Top
Before
After
Bottom
MITSUBISHI ELECTRIC
Menu structure
Edit
in Body ST
Undo
Redo
Cut
Copy
Paste
Delete
Find…
Replace…
Toggle Bookmark
Next Bookmark
Previous Bookmark
Delete all Bookmarks
Edit
in Body SFC
Undo
Redo
Cut
Copy
Paste
Delete
Find…
Replace…
Mark
Macro
Expand Macro
Modify
Insert
씰
씰
Name
Initial Step
Final Step
Macro Step
Entry Step
Exit Step
Step/Transition Unit
Step
Transition
Left Divergence
Right Divergence
Left Convergence
Right Convergence
Label
Jump
GX IEC Developer Reference Manual F – 5
F – 6
Edit
in Declaration editors
Undo
Redo
Cut
Copy
Paste
Delete
Find…
Replace…
New Declaration
씰
Top
Before
After
Bottom
Edit
in Entry Data Monitor (EDM)
Insert Objects…
햲
Next Object
Insert Forced Inputs
햵 햶
Insert Set Inputs
햷 햸
Insert Set Outputs
Clear Device File
Cut
Copy
Paste
Insert Row
Delete
Delete All
Close
Edit
in Show Generated Code
Copy All
Menu structure
MITSUBISHI ELECTRIC
Menu structure
Tools
in Navigator
Expand
Collapse
Tools
in Body IL, MELSEC IL
Edit Network
End Edit
Network List…
Show MELSEC Code Of Networks
Import GX Developer Network
Import MEDOC Network
List Operators/Operands
Create Template
헁
Tracking
씰
New Variable…
Zoom
씰
Start Tracking
Next
Previous
First
Last
Header
Body
Tools
in Body ST
Show MELSEC Code Of Networks
Show MELSEC Code Of Selection
List Operands
List Operators
Create Template
Tracking
씰
New Variable…
Zoom
씰
Start Tracking
Next
Previous
First
Last
Header
Body
GX IEC Developer Reference Manual F – 7
F – 8
Tools
in Body LD
Network Elements
씰
Contact
헂
Contact Negation
Coil
헂
Jump
Return
Function Block
L-Connection Contact
L-Connection Contact Negation
Input Variable
Output Variable
Horizontal Line Segment
Vertical Line Segment
Comment
Lable of the Network
Delete Line
Open Row
Open Column
Define Graphic Macros…
Custom
씰
Custom 1
Custom 2
Custom 3
Custom 4
Custom 5
More Custom…
Select Mode
Interconnect Mode
Auto Connect
Guided Mode
씰
Guided Editing
Overwrite Mode
Insert Mode
Line Mode
Auto Comment
Recalculate Line
Network List…
Show MELSEC Code Of Networks
List Operators/Operands
Tracking
씰
New Variable…
Zoom
씰
Start Tracking
Next
Previous
First
Last
Header
Body
Menu structure
MITSUBISHI ELECTRIC
Menu structure
Tools
in FBD
Network Elements
씰
Jump
Return
Function Block
Input Variable
Output Variable
Horizontal Line Segment
Vertical Line Segment
Comment
Open Row
Open Column
Define Graphic Macros…
Custom
씰
Custom 1
Custom 2
Custom 3
Custom 4
Custom 5
More Custom…
Select Mode
Interconnect Mode
Auto Connect
Recalculate Line
Network List…
Show MELSEC Code Of Networks
List Operators/Operands
Tracking
씰
New Variable…
Zoom
씰
Start Tracking
Next
Previous
First
Last
Header
Body
Tools
in Body SFC
Edit Action Association
Edit Step Comment
Edit Transition Condition
End Edit
List Operands
List Operators
New Variable
Zoom Macro
Zoom Body
Zoom Into
Zoom Back
Find Error
GX IEC Developer Reference Manual F – 9
F – 10
Tools
in Declaration editors
Expand Declaration
Collapse Declaration
Sort
씰
Class
Identifier
Address
헃
Type
Find Overlapping Addresses
Address Batch Replace
햲
Export to Excel
Import from Excel
Tools
in the Entry Data Monitor (EDM)
Expand Declaration
Collapse Declaration
Read from PLC
Write to PLC
Read from File
Write to File
Setup…
Always on top
Tools
when no project is opened
Reorganize Database
Tools
in Show Verify Differences
Next Difference
Previous Difference
Goto Editor
Show Step Number
Menu structure
MITSUBISHI ELECTRIC
Menu structure
Online
Transfer Setup
Start Monitoring (*, see below)
Stop Monitoring
Monitor Header
햲
Entry Data Monitor
Modify Variable Value
Online-Change Mode
햲 햳
Monitoring Mode
Start In Cycle Monitor
햲 햴
Stop In Cycle Monitor
햲 햴
Change Instance…
햲
Start/Stop PLC
햲
PLC Redundancy Mode
햿
PLC Status
PLC Keyword
씰
씰
Ports
Modem
Project
Current
New
햲
햲
Delete
햲
Disable Protection
햺
Enable Protection
햺
Set PLC Time
햿
GX Simulator
햲
Latch Data Backup
PLC Clear
씰
Backup
헆
Delete Backup Data
헆
All
햲
Devices
햹
Latch
햲 햻
Forced Inputs
햵 햶
Format Drive
햲 햻
File Info
햻
Close communications
* for ST / IL see below
Online
specific items: ST / IL
Start Monitoring
씰
Body
Split Window
GX IEC Developer Reference Manual F – 11
Debug
SFC Control
헄
PLC Diagnostics
Ethernet Diagnostics
햵
CC IE Control Diagnostics
햿 헆
MELSECNET Diagnostics
햵
CC-Link(/LT) Diagnostics
햵
System Monitor
햽
Online Module Change
햿
Device Edit
Buffer memory batch
System Errors
User Errors
햲 햵
HW Diagnostics
햲 햵
Scan
햲
Show Step
Forced input output registration/cancellation…
Set selected steps
햻
Reset Selected steps
햻
Replace active by selected steps
햻
Menu structure
F – 12
MITSUBISHI ELECTRIC
Menu structure
View
Toolbar
Statusbar
Horizontal Scrollbar
Grid
Zoom
View mode
Font…
Colors
헅
씰
씰
씰
50%
75%
100%
150%
Standard
Mitsubishi Address
IEC Address
Toggle
Background…
Selection…
Text…
Selected Text…
Read Only Text…
Locked Text…
Foreground…
Monitoring…
Errors…
Shade Left Top…
Shade Right Bottom…
Grid…
Browser Items…
SFC Raster Elements…
Overwrite Mode Cursor
Insert Mode Cursor
Line Mode Cursor
Cursor Fill
ST Keywords…
ST Operators…
ST Comments…
ST Constant Numbers…
ST Constant Strings…
ST Variables…
Save Workspace
Load Workspace
Extended Information
헅
Environment
Configure Status Bar
System Defaults
씰
Navigator
SFC editor
GX IEC Developer Reference Manual F – 13
F – 14
Extras
Project Backup…
Project Restore…
Declare MXChange Tags
햲
Delete MXChange Tags
Update Variables
햲
햲
Export Variables
햲
Find Unused Variables
햲
Double Coil Check
햲
Intelligent Function Utility
씰 Start
햽
Verify System Variables
햲 햽
Options…
SV
씰 Export Alarm Info… 햻
Update Time
햻
Options…
Window
Tile Horizontally
Tile Vertically
Cascade
Arrange Icons
Close All
Navigator
Show Compile/Check Messages
Show Next Error
Show Previous Error
Show Next Warning
Show Previous Warning
1 Window 1
2 Window 2
3 Window 3
4 Window 4
Help
Index
Overview
Glossary
Error Messages
Search…
How to use Help
About…
Menu structure
MITSUBISHI ELECTRIC
Compliance List
G Compliance List
This list provides a description of all the features of the GX IEC Developer programming and documentation system that comply with the specifications of IEC standard 61131, Part 3.
The format of the list corresponds to the tables in IEC 61131-3. This makes it possible to obtain additional information quickly by referring to the corresponding tables and the accompanying texts in the IEC standard publication.
Character set features
4b
5a
5b
6a
6b
3a
3b
4a
No.
Description
1 ISO/IEC 646 character set “A-Z,_”
2 Lower case characters “a-z”
Number sign “#”
Pound sign “£”
Dollar sign “$”
Currency sign
Vertical bar “|”
Exclamation mark “!”
Left and right brackets “[]”
Left and right parentheses “()”
Tab. G-1:
Character set features
Note
Supported
Supported
Supported
Not supported
Supported
Not supported
Not supported
Not supported
Supported (Arrays)
Supported
Identifier features
No.
Description
1 Upper case and numbers
2 Upper and lower case, numbers, embedded underlines
3 Upper and lower case, numbers, leading or embedded underlines
Tab. G-2:
Identifier features
Comment feature
No.
Description
1 (*This is a comment*)
Tab. G-3:
Comment feature
Note
Supported
Supported
Supported
Note
Supported
GX IEC Developer Reference Manual G – 1
G – 2
Compliance List
Numeric literals
4
5
6
7
8
No.
Description
1
2
3
Integer literals
Real literals
Real literals with exponents
Base 2 literals
Base 8 literals
Base 16 literals
Boolean zero (0) and one (1)
Boolean FALSE and TRUE
Tab. G-4:
Numeric literals
Character string literals
No.
Description
1 ‘’, ‘A’, ‘ ‘, ‘$", ‘$R$L", ‘$0D$0A’, ‘$$1.00’
Tab. G-5:
Character string literals
Note
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Note
Supported
Two-character combinations in character strings
6
7
8
3
4
5
No.
Description
2 $$
$’
$L or $I
$N or $n
$P or $p
$R or $r
$T or $t
Tab. G-6:
Two-character combinations in character strings
Note
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Duration literal features
No.
Description
1a Duration literals without underlines:
Short prefix
1b
2a
2b
Long prefix
Duration literals with underlines:
Short prefix
Long prefix
Tab. G-7:
Duration literal features
Note
Supported
Supported
Supported
Supported
MITSUBISHI ELECTRIC
Compliance List
Date and time of day literals
4
5
6
No.
Description
1
2
3
Date literals (long prefix)
Date literals (long prefix)
Time of day literals (long prefix)
Time of day literals (short prefix)
Date and time literals (long prefix)
Date and time literals (short prefix)
Tab. G-8:
Date and time of day literals
Note
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Date and time of day literals notation
No.
Description
1 Time literals notation
Tab. G-9:
Date and time of day literals notation
Note
Not supported
Elementary data types
17
18
19
20
14
15
16
11
12
13
8
9
10
5
6
7
2
3
4
No.
Description
1 BOOL
SINT
INT
DINT
LINT
USINT
UINT
UDINT
ULINT
REAL
LREAL
TIME
DATE
TIME_OF_DAY or TOD
DATE_AND_TIME or DT
STRING
BYTE
WORD
DWORD
LWORD
Plus: EDGE, CHANGE, SGRAY, GRAY, DGRAY, BCD, WFIX, DFIX
Tab. G-10: Elementary data types
Note
Supported
Not supported
Supported
Supported
Not supported
Not supported
Not supported
Not supported
Not supported
Supported
Not supported
Supported
Not supported
Not supported
Not supported
Supported
Not supported
Supported
Supported
Not supported
GX IEC Developer Reference Manual G – 3
G – 4
Hierarchy of generic data types
No.
Description
ANY
ANY_NUM
ANY_REAL
REAL
ANY_INT
DINT
INT
ANY _BIT
DWORD
WORD
BOOL
TIME
Tab. G-11: Hierarchy of generic data types
Data type declaration feature
2
3
4
No.
Description
1 Direct derivation of elementary data types
5
Enumerated data types
Subrange data types
Array data types
Structured data types
Tab. G-12: Data type declaration feature
Default initial values
No.
Description
BOOL = FALSE
INT, DINT = 0
WORD, DWORD = 0
REAL = 0.0
TIME = T#0s
Tab. G-13: Default initial values
Note
Compliance List
Note
Not supported
Not supported
Not supported
Supported
Supported
Note
Supported
Supported
Supported
Supported
Supported
MITSUBISHI ELECTRIC
Compliance List
Data type initial value declaration features
4
5
6
No.
Description
1
2
3
Initialisation of directly derived types
Initialisation of enumerated data types
Initialisation of subrange data types
Initialisation of array data types
Initialisation of structured data type elements
Initialisation of derived structure data types
Tab. G-14: Data type initial value declaration features
Note
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Location and size prefix features for directly represented variables
7
8
9
4
5
6
No.
Description
1
2
3
I, Input location
Q, Output location
M, Memory location
X, Single bit size
None, Single bit size
B, Byte (8 bits) size
W, Word (16 bits) size
D, Double word (32 bits) size
L, Long (quad) word (64 bits) size
Note
Supported
Supported
Supported
Supported
Not supported
Not supported
Supported
Supported
Not supported
Tab. G-15: Location and size prefix features for directly represented variables
Variable declaration keywords
No.
Description
VAR / VAR_CONSTANT
VAR_INPUT
VAR_OUTPUT
VAR_IN_OUT
VAR_GLOBAL / VAR_GLOBAL_CONSTANT
VAR_ACCESS
RETAIN
CONSTANT
AT
Tab. G-16: Variable declaration keywords
Note
Supported
Supported
Supported
Supported
Supported
Not supported
Not supported
Not supported
Supported
GX IEC Developer Reference Manual G – 5
G – 6
Variable type assignment features
4
5
6
7
8
No.
Description
1
2
3
Declaration of directly represented, non-retentive variables
Declaration of directly represented retentive variables
Declaration of locations of symbolic variables
Array location assignment
Automatic memory allocation of symbolic variables
Array declaration
Retentive array declaration
Declaration of structured variables
Tab. G-17: Variable type assignment features
Variable initial value assignment features
7
8
9
5
6
3
4
No.
Description
1 Initialisation of directly represented, non-retentive variables
2 Initialisation of directly represented retentive variables
Location and initial value assignment to symbolic variables
Array location assignment and initialisation
Initialisation of symbolic variables
Array initialisation
Retentive array declaration and initialisation
Initialisation of structured variables
Initialisation of constants
Tab. G-18: Variable initial value assignment features
Graphical negation of Boolean signals
No.
Description
1
2
Negated input
Negated output
Tab. G-19: Graphical negation of Boolean signals
Note
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Note
Supported
Supported
Compliance List
Note
Supported
Not supported
Supported
Supported
Supported
Supported
Not supported
Supported
MITSUBISHI ELECTRIC
Compliance List
Use of EN input and ENO output
No.
Description
1 Use of EN and ENO
Required for Ladder Diagram (LD) language
2
3
Use of EN and ENO
Optional for Function Block Diagram (FBD) language
FBD without EN and ENO
Tab. G-20: Use of EN input and ENO output
Note
Supported
Supported
Supported
Typed and overloaded functions
No.
Description
1 Overloaded functions (untyped)
2 Typed functions
* Implicit typing through passing of the actual parameters
Tab. G-21: Typed and overloaded functions
Note
Supported*
Not supported
Type conversion function features
3
4
No.
Description
1 *_TO_**
2 TRUNC
BCD_TO_**
*_TO_BCD
Tab. G-22: Type conversion function features
Note
Supported
Not supported
Supported
Supported
Standard functions with one numeric variable
9
10
11
6
7
8
3
4
5
No.
Description
1 ABS
2 SQRT
LN
LOG
EXP
SIN
COS
TAN
ASIN
ACOS
ATAN
* Only for PLC systems that support floating point values: Q, QnA, AnA, AnU
Tab. G-23: Standard functions with one numeric variable
Note
Supported
Supported*
Supported*
Not supported
Supported*
Supported*
Supported*
Supported*
Supported*
Supported*
Supported*
GX IEC Developer Reference Manual G – 7
G – 8
Compliance List
Standard arithmetic functions
15
16
17
18
No.
Description
12
13
14
ADD
MUL
SUB
DIV
MOD
EXPT
Note
Supported
Supported
Supported
Supported
Supported
Supported
MOVE Supported*
* Only for PLC systems that support floating point values: Q, QnA, AnA, AnU Supported
Tab. G-24: Standard arithmetic functions
Standard bit-shift functions
3
4
No.
Description
1 SHL
2 SHR
ROR
ROL
Tab. G-25: Standard bit-shift functions
Note
Supported
Supported
Supported
Supported
Standard bitwise Boolean functions
7
8
No.
Description
5 AND
6 OR
XOR
NOT
Tab. G-26: Standard bitwise Boolean functions
Standard selection functions
No.
Description
1 SEL
2a
2b
3
4
MAX
MIN
LIMIT
MUX
Tab. G-27: Standard selection functions
Note
Supported
Supported
Supported
Supported
Note
Supported
Supported
Supported
Supported
Supported
MITSUBISHI ELECTRIC
Compliance List
Standard comparison functions
8
9
10
No.
Description
5
6
7
GT
GE
EQ
LE
LT
NE
Tab. G-28: Standard comparison functions
Standard character string functions
6
7
8
9
3
4
5
No.
Description
1 LEN
2 LEFT
RIGHT
MID
CONCAT
INSERT
DELETE
REPLACE
FIND
* Only for PLC systems that support character strings: Q, QnA
Tab. G-29: Standard character string functions
Note
Supported
Supported
Supported
Supported
Supported
Supported
Note
Supported *
Supported *
Supported *
Supported *
Supported *
Supported *
Supported *
Supported *
Supported *
GX IEC Developer Reference Manual G – 9
G – 10
Compliance List
Functions of time data types
10
11
12
13
14
7
8
9
4
5
6
No.
Description
1
2
3
ADD (TIME, TIME, TIME)
ADD (TOD, TIME, TOD)
ADD (DT, TIME, DT)
SUB (TIME, TIME, TIME)
SUB (DATE, DATE, TIME)
SUB (TOD, TIME, TOD)
SUB (TOD, TOD, TIME)
SUB (DT, TIME, DT)
SUB (DT, DT, TIME)
MUL (TIME, ANY_NUM, TIME)
DIV (TIME, ANY_NUM, TIME)
CONCAT (DATE, TOD, DT)
DT_TO_TOD
DT_TO_D
Tab. G-30: Functions of time data types
Functions of enumerated data types
3
4
No.
Description
1 SEL
2 VIUX
EQ
NE
Tab. G-31: Functions of enumerated data types
Function block I/O parameter usage features
No.
Description
3
4
1
2
Input read
Input write
Output read
Output write
Tab. G-32: Function block I/O parameter usage features
Note
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Note
Not supported
Not supported
Not supported
Not supported
Note
Supported
Supported
Supported
Supported
MITSUBISHI ELECTRIC
Compliance List
Function block declaration features
8a
8b
9a
9b
4a
4b
5a
5b
6a
No.
Description
1
2
3
RETAIN qualifier on internal variables
RETAIN qualifier on output variables
RETAIN qualifier on internal function blocks
6b
Input/output declaration (textual)
Input/output declaration (graphical)
Function block instance name as input (textual)
Function block instance name as input (graphical)
Function block instance name as input/output
(textual)
Function block instance name as input/output
(graphical)
Declaration of rising edge inputs (textual)
Declaration of falling edge inputs (textual)
Declaration of rising edge inputs (graphical)
Declaration of falling edge inputs (graphical)
Tab. G-33: Function block declaration features
Standard bistable function blocks
No.
Description
1 Bistable function block (set dominant)
2 Bistable function block (reset dominant)
3 Semaphore with non-interruptible “Test and Set”
Tab. G-34: Standard bistable function blocks
Standard edge detection function blocks
No.
Description
1 Rising edge detector
2 Falling edge detector
Tab. G-35: Standard edge detection function blocks
Note
Not supported
Not supported
Not supported
Supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Note
Supported
Supported
Not supported
Note
Supported
Supported
GX IEC Developer Reference Manual G – 11
G – 12
Compliance List
Standard counter function blocks
No.
Description
1
2
3
Up-counter
Down-counter
Up/Down-counter
Tab. G-36: Standard counter function blocks
Note
Supported
Supported
Supported
Standard timer function blocks
2b
3a
3b
No.
Description
1 TP
2a TON
T—-0
TOF
0—-T
Tab. G-37: Standard timer function blocks
Program declaration features
No.
1-9b
10
21
Description
Features 1 to 9b of table 23
Formal input and output parameters
11-14 Features 1-4 of table 17
15-18 Features 1-4 of table 18
19 Use of directly represented variables
20 VAR_GLOBAL...END_VAR
declaration within a program
VAR_ACCESS...END_VAR
declaration within a program
Tab. G-39: Program declaration features
Note
Supported
Supported
Not supported
Supported
Not supported
Standard timer function blocks — timing diagrams
No.
Description
1
2
3
TP
TON
TOF
Tab. G-38: Standard timer function blocks — timing diagrams
Note
Supported
Supported
Supported
Note
Not supported
Supported
Supported
Not supported
MITSUBISHI ELECTRIC
Compliance List
Step features
No.
1
2
3a
3b
4
Description
Step - graphical form with directed links
Initial step - graphical form with directed links
Step - textual form without directed links
Initial step - textual form without directed links
Step flag - general form: name.X = a variable of type BOOL
Step flag - direct connection of Boolean variable name.X to right side of step
Step elapsed time - general form name.T = a variable of type TIME
Tab. G-40: Step features
Note
Supported
Not supported
Not supported
Not supported
Not supported
Transitions and transition conditions
5
6
7
4
4a
4b
7a
7b
7c
7d
No.
1
2
3
Description
Transition condition using ST language
Transition condition using LD language
Transition condition using FBD language
Use of transition connector
Transition condition in LD language with transition connector
Transition condition in FBD language with transition connector
Transition condition in ST in textual form
Transition condition in IL in textual form
Transition with transition name
Transition condition using LD language
Transition condition using FBD language
Transition condition using IL language
Transition condition using ST language
* Supported through connectors
Tab. G-41: Transitions and transition conditions
Declaration of actions
No.
1
2l
2s
2f
3s
3i
Description
Any Boolean variable declared in a VAR or VAR_OUTPUT block, or their graphical equivalents, can be an action.
Graphical declaration of an action in LD language
Inclusion of SFC elements in an action
Graphical declaration of an action in FBD language
Textual declaration of an action in ST language
Textual declaration of an action in IL language
Tab. G-42: Declaration of actions
Note
Supported
Supported
Not supported
Supported
Supported
Supported
Note
Supported
*
*
Supported
Supported
Supported
Not supported
Not supported
Supported
Supported
Supported
Supported
Supported
GX IEC Developer Reference Manual G – 13
G – 14
Step/action association
No.
1
2
3
4
Description
Action block
Concatenated action blocks
Textual step body with action calls
Action block “d” field
* Implemented through the editors
Tab. G-43: Step/action association
Action block features
6
7
8
9
3
4
5
No.
1
2
Description
“a”: Qualifier
“b”: Action name
“c”: Boolean “indicator” variables
“d”: Action using IL language
“d”: Action using ST language
“d”: Action using LD language
“d”: Action using FBD language
Use of action blocks in ladder diagrams
Use of action blocks in function block diagrams
Tab. G-44: Action block features
Action qualifiers
8
9
10
5
6
7
2
3
4
No.
1
Description
None: Non-stored (mull qualifier)
N: Non-stored
R: overriding Reset
S: Set (stored)
L: time Limited
D: time Delayed
P: Pulse (edge)
SD: Stored and time Delayed
DS: Delayed and Stored
SL: Stored and time Limited
Tab. G-45: Action qualifiers
Compliance List
Note
*
*
Not supported
Not supported
Note
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Note
Supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
MITSUBISHI ELECTRIC
Compliance List
Sequence evolution
No.
1
2a
2b
2c
Description
Divergence of sequence selection with user-defined mutual exclusion of transition conditions as specified by IEC 848.
Note
Single sequence
Divergence of sequence selection, priority of evaluation from left to right
Supported
Supported
Divergence of sequence selection, user-defined priority of evaluation (numbers) Not supported
Not supported
Supported
Supported
3
4
Convergence of sequence selection
Simultaneous sequences — divergence Simultaneous sequences — convergence
5abc Sequence skip (corresponding to 2a, b, c)
6abc Sequence loop (corresponding to 2a, b, c)
7 Directional arrows in SFC charts
Supported (2a only)
Not supported
Not supported
Tab. G-46: Sequence evolution
Compatible SFC features (graphical only)
43
44
45
46
57
No.
40
41
42
Description
1, 3a, 3b, 4
1, 2, 3, 4, 4a, 4b, 7, 7a, 7b
1, 2l, 2s, 2f
1, 2, 4
1 to 9
1 to 10
1 to 7 all
Tab. G-47: Compatible SFC features (graphical only)
Note
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
SFC minimal compliance requirements (graphical only)
45
46
47
No.
40
41
42
43
Description
1
1 or 2 or 3 or (4 and (4a or 4b)) or (7 and (7a or 7b or 7c or 7d))
1 or 2l or 2f
1 or 2 or 4
1 or 2
1 and (2a or 2b or 2c) and 3 and 4
(1 or 2) and (3 or 4) and (5 or 6) and (7 or 8) and (9 or 10) and (11 or 12)
* Implemented through the editors
Tab. G-48: SFC minimal compliance requirements (graphical only)
Note
Supported
Supported
Supported
*
Supported
Supported
Not supported
GX IEC Developer Reference Manual G – 15
G – 16
Compliance List
Configuration and resource declaration features
10b
10c
10d
10e
10f
7
8a
8b
9a
9b
10a
6a
6b
6c
4
5a
5b
No.
1
2
3
Description
CONFIGURATION...END_CONFIGURATION construction
VAR_GLOBAL...END_VAR construction within CONFIGURATION
RESOURCE...ON...END_RESOURCE construction
VAR_GLOBAL...END_VAR construction within RESOURCE
Periodic TASK construction within RESOURCE
Non-periodic TASK construction within RESOURCE
PROGRAM declaration PROGRAM-to-TASK association
PROGRAM declaration with FUNCTION BLOCK-to-TASK association
PROGRAM declaration with no TASK association
Declaration of directly represented variables in VAR_GLOBAL
Connection of directly represented variables to PROGRAM inputs
Connection of GLOBAL variables to PROGRAM inputs
Connection of PROGRAM outputs to directly represented variables
Connection of PROGRAM outputs to GLOBAL variables
VAR_ACCESS...END_VAR construction
Access paths to directly represented variables
Access paths to PROGRAM inputs
Access paths to GLOBAL variables in RESOURCES
Access paths to GLOBAL variables in CONFIGURATIONS
Access paths to PROGRAM outputs
Tab. G-49: Configuration and resource declaration features
Note
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
Task features
3a
3b
4a
4b
No.
1a
1b
2a
2b
5a
5b
Description
Textual declaration of periodic TASKS according to feature 5a of table 49
Note
Not supported
Textual declaration of non-periodic TASKS according to feature 5b of table 49 Not supported
Graphical representation of periodic TASKS
Graphical representation of non-periodic TASKS
Textual association with PROGRAMS according to feature 6a of table 49
Supported
Supported
Not supported
Textual association with FUNCTION BLOCKS according to feature 6b of table 49 Not supported
Graphical association with PROGRAMS (within RESOURCES)
Supported
Graphical association with FUNCTION BLOCKS
(within PROGRAMS in RESOURCES)
Supported
Non-pre-emptive scheduling
Pre-emptive scheduling
Supported
Not supported
Tab. G-50: Task features
MITSUBISHI ELECTRIC
Compliance List
Examples of instruction fields
No.
1
Description
Label, Operator, Operand
Tab. G-51: Examples of instruction fields
Instruction List (IL) operators
GT, (
GE, (
EQ, (
NE, (
LE, (
LT, (
JMP, C, N
CAL, C, N
RET, C, N
)
Description
LD
ST
S, R
AND, N, (
&, N, (
OR, N, (
XOR, N, (
ADD, (
SUB, (
MUL, (
DIV, (
18
19
20
21
15
16
17
12
13
14
9
10
11
6
7
8
3
4
5
No.
1
2
Tab. G-52: Instruction List (IL) operators
Note
Supported
Function block invocation features for IL language
No.
1
2
3
Description
CALL with input parameter list
CALL with load/store of input parameters
Use of input operators
Tab. G-53: Function block invocation features for IL language
Note
Supported
Supported
Not supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Note
Supported
Supported
Supported
Supported
Not supported
Supported
Supported
Supported
Supported
Supported
Supported
GX IEC Developer Reference Manual G – 17
G – 18
Standard function block input operators for IL language
No.
Description
!!!Only relevant when supported in 53.3!!!
Tab. G-54: Standard function block input operators for IL language
Note
Compliance List
Operators of the ST language
9
10
11
6
7
8
3
4
5
No.
1
2
15
16
17
12
13
14
=
<>
&
AND
XOR
OR
Description
(Expression) parenthesisation
Function call (argument list)
**
- (Negation)
NOT
/
*
MOD
+
- (Subtraction)
<, >, <=, >=
Tab. G-55: Operators of the ST language
Note
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
ST language statements
8
9
10
5
6
7
2
3
4
No.
1
Description
Assignment :=
Function block invocation and FB output usage
RETURN
IF
CASE
FOR
WHILE
REPEAT
EXIT
Empty statement
Tab. G-56: ST language statements
Note
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
MITSUBISHI ELECTRIC
Compliance List
Representation of lines and blocks
7
8
9
4
5
6
No.
1
2
3
10
11
12
13
14
Description
Horizontal lines: ISO 646 “–” character, semigraphic
Horizontal lines, graphic
Vertical lines ISO 646 “+” character, semigraphic
Note
Not supported
Supported
Not supported
Vertical lines, graphic
Horizontal/vertical connection ISO 646 “+” character, semigraphic
Horizontal/vertical connection, graphic
Supported
Not supported
Supported
Line crossing without connection ISO 646 characters, semigraphic
Line crossing without connection, graphic
Not supported
Supported
Connected and non-connected corners ISO 646 “+” character, semigraphic Not supported
Connected and non-connected corners, graphic
Blocks with connecting lines, ISO 646 character, semigraphic
Blocks with connecting lines, graphic
Connectors using ISO 646 characters, semigraphic
Connectors, graphic
Supported
Not supported
Supported
Not supported
Supported
Tab. G-57: Representation of lines and blocks
Graphic execution control elements, examples
5
6
7
8
2
3
4
No.
1
Description
Unconditional jump in FBD language
Unconditional jump in LD language
Conditional jump in FBD language
Conditional jump in LD language
Conditional return in LD language
Conditional return in FBD language
Unconditional return from functions and function blocks
Alternative representation in LD language
Tab. G-58: Graphic execution control elements, examples
Note
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Power bar
No.
1
2
Description
Left power bar with attached horizontal link
Right power bar with attached horizontal link
Tab. G-59: Power bar
Note
Supported
Not supported
GX IEC Developer Reference Manual G – 19
G – 20
Link elements
No.
1
2
Description
Horizontal link
Vertical link (with attached horizontal links)
Tab. G-60: Link elements
Contacts
4
5
6
7
No.
1
2
3
Description
Normally open contact (make) —| |—
Normally open contact (make) —! !—
Normally closed contact (break) —| / |—
Normally closed contact (break) —! / !—
Positive transition-sensing contact —| P |—
Positive transition-sensing contact —! P !—
Negative transition-sensing contact —| N |—
Negative transition-sensing contact —! N !—
* Graphical
Tab. G-61: Contacts
Coils (terminating operations)
7
8
9
5
6
3
4
No.
1
2
Description
Coil —( )—
Negated coil —( / )—
SET (latch) coil —( S )—
RESET (unlatch) coil —( R )—
Retentive (memory) coil —( M )—
SET retentive (memory) coil —( SM )—
RESET retentive (memory) coil —( RM )—
Positive transition-sensing coil —( P )—
Negative transition-sensing coil —( N )—
* Graphical
Tab. G-62: Coils (terminating operations)
Compliance List
Note
Supported
Supported
Note
Supported *
Not supported *
Supported *
Not supported *
Not supported *
Not supported *
Not supported *
Not supported *
Note
Supported *
Supported *
Supported *
Supported *
Not supported
Not supported
Not supported
Not supported
Not supported
MITSUBISHI ELECTRIC
Index
Index
A
Absolute label · · · · · · · · · · · · · · · · · · 8-124
Accumulator · · · · · · · · · · · · · · · · · · · · 6-14
Action · · · · · · · · · · · · · · · · · · · · · · · · A-1
Creating · · · · · · · · · · · · · · · · · · · · 4-19
Pool · · · · · · · · · · · · · · · · · · · · · · · A-1
Actual parameter
Function block· · · · · · · · · · · · · · · · · 6-60
Glossary · · · · · · · · · · · · · · · · · · · · A-1
Address
Absolute address· · · · · · · · · · · · · · · · 6-6
MITSUBISHI address · · · · · · · · · · · · · 6-6
Array · · · · · · · · · · · · · · · · · · · · · · · · 6-71
Calling · · · · · · · · · · · · · · · · · · · · · 6-72
Declaration · · · · · · · · · · · · · · · · · · 6-71
Entry data monitor · · · · · · · · · · · · · · 9-72
Programming · · · · · · · · · · · · · · · · · 6-71
ASCII file
Export· · · · · · · · · · · · · · · · · · · · · 8-116
Auto comment · · · · · · · · · · · · · · · · · · 7-26
Auto Update · · · · · · · · · · · · · · · · · · · · 6-12
Autoconnect function · · · · · · · · · · · · · · 3-59
Autorouting function · · · · · · · · · · · · · · · 3-60
B
Body
Editing · · · · · · · · · · · · · · · · · · · · · 3-40
Error check · · · · · · · · · · · · · · · · · · · 8-1
Glossary · · · · · · · · · · · · · · · · · · · · A-1
Information · · · · · · · · · · · · · · · · · · 4-22
Opening · · · · · · · · · · · · · · · · · · · · 3-40
User interface · · · · · · · · · · · · · · · · · · 3-1
Boot setting · · · · · · · · · · · · · · · · · · · · 5-37
C
Call Tree · · · · · · · · · · · · · · · · · · · · · · 4-24
CC-Link
Interrupt settings · · · · · · · · · · · · · · · 5-67
Settings · · · · · · · · · · · · · · · · · · · · 5-62
Station information · · · · · · · · · · · · · · 5-64
Character mode · · · · · · · · · · · · · · · · · 7-23
Characters
special · · · · · · · · · · · · · · · · · · · · · 2-25
Class· · · · · · · · · · · · · · · · · · · · · · · · · 6-5
Closing
Dialogue box · · · · · · · · · · · · · · · · · 3-16
Object · · · · · · · · · · · · · · · · · · · · · 3-14
Window · · · · · · · · · · · · · · · · · · · · 3-14
Code Generation · · · · · · · · · · · · · · · · · 2-39
Collapsing· · · · · · · · · · · · · · · · · · · · · · 3-6
Colors · · · · · · · · · · · · · · · · · · · · · · · 3-24
Column widths · · · · · · · · · · · · · · · · · · 3-35
COM Port · · · · · · · · · · · · · · · · · · · · · 8-15
Comment
Editing · · · · · · · · · · · · · · · · · · · · · 3-53
Entering · · · · · · · · · · · · · · · · · · · · 3-58
Glossary · · · · · · · · · · · · · · · · · · · · A-2
Graphical editor · · · · · · · · · · · · · · · · 3-54
Object · · · · · · · · · · · · · · · · · · · · · 4-21
Sequential Function Chart· · · · · · · · · · 6-28
SFC step · · · · · · · · · · · · · · · · · · · · 3-7
Text editor · · · · · · · · · · · · · · · · · · · 3-46
Variable declaration · · · · · · · · · · · · · · 6-5
Common keys
Keyboard commands · · · · · · · · · · · · · B-2
Compatibility · · · · · · · · · · · · · · · · 2-2, 10-21
Compiling · · · · · · · · · · · · · · · · · · · · · · 8-3
Glossary · · · · · · · · · · · · · · · · · · · · A-2
Object · · · · · · · · · · · · · · · · · · · · · · 8-4
Project · · · · · · · · · · · · · · · · · · · · · · 8-3
Compiling status
Project · · · · · · · · · · · · · · · · · · · · · · 4-5
Compliance list · · · · · · · · · · · · · · · · · · G-1
Computer link module
Glossary · · · · · · · · · · · · · · · · · · · · A-2
Installation · · · · · · · · · · · · · · · · · · · 2-61
GX IEC Developer Reference Manual I
Index
Consistency · · · · · · · · · · · · · · · · · · · 8-100
Copyright · · · · · · · · · · · · · · · · · · · · · · 2-3
Counter
Counter function · · · · · · · · · · · · · · · 6-74
Counter function block · · · · · · · · · · · · 6-75
Extended counter · · · · · · · · · · · · · · · 5-32
Latch range · · · · · · · · · · · · · · · · · · 5-32
Local counter · · · · · · · · · · · · · · · · · 6-75
Programming · · · · · · · · · · · · · · · · · 6-74
CPU type · · · · · · · · · · · · · · · · · · · · · 5-72
Cross Reference· · · · · · · · · · · · · · 2-20, 4-38
Creating · · · · · · · · · · · · · · · · · · · · 4-38
MMP700.INI· · · · · · · · · · · · · · · · · · · 2-8
Options· · · · · · · · · · · · · · · · · · · · · 2-20
Query criteria · · · · · · · · · · · · · · · · · 4-39
CSV variable export · · · · · · · · · · · · · · 8-117
CSV-Export · · · · · · · · · · · · · · · · · · · · 2-21
Device editor · · · · · · · · · · · · · · · · · · · 9-48
32-bit value · · · · · · · · · · · · · · · · · · 9-53
Copy · · · · · · · · · · · · · · · · · · · · · · 9-50
Cut · · · · · · · · · · · · · · · · · · · · · · · 9-50
Deleting devices · · · · · · · · · · · · · · · 9-51
Display mode · · · · · · · · · · · · · · · · · 9-51
Excel file · · · · · · · · · · · · · · · · · · · · 9-50
Excel file extension · · · · · · · · · · · · · · 4-2
Glossary · · · · · · · · · · · · · · · · · · · · A-2
Inserting devices · · · · · · · · · · · · · · · 9-51
Keyboard commands · · · · · · · · · · · · B-10
MMP700.INI· · · · · · · · · · · · · · · · · · · 2-9
Paste · · · · · · · · · · · · · · · · · · · · · · 9-50
Pop-up menu · · · · · · · · · · · · · · · · · 9-50
Table in Microsoft Excel · · · · · · · · · · · 9-54
Worksheet · · · · · · · · · · · · · · · · · · · 9-49
Device Setting · · · · · · · · · · · · · · · · · · 5-33
Dialog box
Closing · · · · · · · · · · · · · · · · · · · · · 3-16
Keyboard commands · · · · · · · · · · · · · B-6
Selecting · · · · · · · · · · · · · · · · · · · · 3-16
System image · · · · · · · · · · · · · · · · · 8-11
Dialogue box · · · · · · · · · · · · · · · · · · · 3-16
Double Coil Check · · · · · · · · · · · · · · · · 4-41
D
Data type
Default · · · · · · · · · · · · · · · · · · · · · 3-39
Glossary · · · · · · · · · · · · · · · · · · · · A-2
Hierarchy · · · · · · · · · · · · · · · · · · · 6-11
Selection · · · · · · · · · · · · · · · · · · · · 3-38
Variable declaration · · · · · · · · · · · · · · 6-5
Data unit type · · · · · · · · · · · · · · · · · · · 6-66
Creating · · · · · · · · · · · · · · · · · · · · 4-19
Declaration · · · · · · · · · · · · · · · · · · 6-66
Glossary · · · · · · · · · · · · · · · · · · · · A-2
Pool · · · · · · · · · · · · · · · · · · · · · · · 4-4
Programming · · · · · · · · · · · · · · · · · 6-66
Debugging · · · · · · · · · · · · · · · · · · · · · 9-1
Scan · · · · · · · · · · · · · · · · · · · · · · 9-45
Default setting
Screen display · · · · · · · · · · · · · · · · 3-25
Status bar · · · · · · · · · · · · · · · · · · · 3-12
E
Editing
Body · · · · · · · · · · · · · · · · · · · · · · 3-40
Editor · · · · · · · · · · · · · · · · · · · · · · 3-40
General · · · · · · · · · · · · · · · · · · · · 3-26
Graphical editor · · · · · · · · · · · · · · · · 3-54
Object · · · · · · · · · · · · · · · · · · · · · 3-10
Table · · · · · · · · · · · · · · · · · · · · · · 3-34
Text editor · · · · · · · · · · · · · · · · · · · 3-53
Editor · · · · · · · · · · · · · · · · · · · · · · · · A-3
Editing · · · · · · · · · · · · · · · · · · · · · 3-40
Text editor · · · · · · · · · · · · · · · · · · · 3-45
EN/ENO · · · · · · · · · · · · · · · · · · · · · · 4-23
Function block· · · · · · · · · · · · · · · · · 3-65
Programming · · · · · · · · · · · · · · · · · · E-4
II
MITSUBISHI ELECTRIC
Index
Entry Data Monitor · · · · · · · · · · · · · · · · 9-66
32-bit register · · · · · · · · · · · · · · · · · 9-71
Array · · · · · · · · · · · · · · · · · · · · · · 9-72
Changing values · · · · · · · · · · · · · · · 9-71
Deleting objects· · · · · · · · · · · · · · · · 9-68
File extension · · · · · · · · · · · · · · · · · · 4-2
Glossary · · · · · · · · · · · · · · · · · · · · A-3
Inserting objects · · · · · · · · · · · · · · · 9-67
Keyboard commands · · · · · · · · · · · · · B-9
MMP703.INI· · · · · · · · · · · · · · · · · · · 2-9
Opening · · · · · · · · · · · · · · · · · · · · 9-71
Pop-up menu · · · · · · · · · · · · · · · · · 9-70
Read from file · · · · · · · · · · · · · · · · · 9-68
Structures · · · · · · · · · · · · · · · · · · · 9-72
Worksheet · · · · · · · · · · · · · · · · · · · 9-66
Environment· · · · · · · · · · · · · · · · · · · · 3-22
Error check
Error message file · · · · · · · · · · · · · · 9-44
Hardware diagnosis · · · · · · · · · · · · · 9-45
Scan · · · · · · · · · · · · · · · · · · · · · · 9-45
System errors · · · · · · · · · · · · · · · · · 9-43
User-defined errors· · · · · · · · · · · · · · 9-44
Ethernet
Installation A/QnA · · · · · · · · · · · · · · 2-64
Installation System Q · · · · · · · · · · · · 2-67
PLC parameters · · · · · · · · · · · · · · · 5-46
Expanding· · · · · · · · · · · · · · · · · · · · · · 3-5
Export · · · · · · · · · · · · · · · · · · · 2-28, 8-116
ASCII files · · · · · · · · · · · · · · · · · · 8-116
File · · · · · · · · · · · · · · · · · · · · · · · · 4-2
Object· · · · · · · · · · · · · · · · · · · · · 8-116
Project · · · · · · · · · · · · · · · · · · · · 8-116
To Eprom · · · · · · · · · · · · · · · · · · · 8-116
External variables · · · · · · · · · · · · · · · · 10-1
Function· · · · · · · · · · · · · · · · · · · · · · · A-3
Declaration · · · · · · · · · · · · · · · · · · 6-52
Editing support in text editor · · · · · · · · 6-53
Programming · · · · · · · · · · · · · · · · · 6-51
Using timer · · · · · · · · · · · · · · · · · · 6-51
Function block · · · · · · · · · · · · · · · · · · 6-55
Calling · · · · · · · · · · · · · · · · · · · · · 6-58
Declaration · · · · · · · · · · · · · · · · · · 6-56
Editing support in text editor · · · · · · · · 6-59
Global FB · · · · · · · · · · · · · · · · · · · 6-65
Glossary · · · · · · · · · · · · · · · · · · · · A-3
Instantiation · · · · · · · · · · · · · · · · · · 6-57
Macrocode execution · · · · · · · · · · · · 6-61
Macrocode execution option · · · · · · · · 4-23
MC-MCR execution· · · · · · · · · · · · · · 6-61
MC-MCR option· · · · · · · · · · · · · · · · 4-23
Using timer · · · · · · · · · · · · · · · · · · 6-55
Function Block Diagram · · · · · · · · · · · · · A-4
See also Graphical editor
FX Configurator-EN · · · · · · · · · · · · · · · 11-3
G
General · · · · · · · · · · · · · · · · · · · · · · 2-25
Generated code
Keyboard commands · · · · · · · · · · · · · B-9
Global DUT · · · · · · · · · · · · · · · · · · · · 6-67
Global Function Block · · · · · · · · · · · · · · 6-65
Global variable · · · · · · · · · · · · · · · · · · · 6-5
Glossary · · · · · · · · · · · · · · · · · · · · A-4
Project Navigator · · · · · · · · · · · · · · · · 4-4
Graphic · · · · · · · · · · · · · · · · · · · · · · 2-27
F
File structure
MELSEC Q series · · · · · · · · · · · · · · 8-91
Files · · · · · · · · · · · · · · · · · · · · · · · · · 4-1
Fonts · · · · · · · · · · · · · · · · · · · · · · · · 3-23
Formal parameter · · · · · · · · · · · · · · · · 6-60
Glossary · · · · · · · · · · · · · · · · · · · · A-3
GX IEC Developer Reference Manual III
Index
Graphical editor· · · · · · · · · · · · · · · · · · 6-15
Anchor point · · · · · · · · · · · · · · · · · · 3-62
Autoconnect · · · · · · · · · · · · · · · · · · 3-59
Autorouting · · · · · · · · · · · · · · · · · · 3-60
Changing editing area spacing · · · · · · · 3-58
Comment · · · · · · · · · · · · · · · · · · · 3-54
Configuring input signals · · · · · · · · · · 3-63
Configuring output coils · · · · · · · · · · · 3-64
Context menu · · · · · · · · · · · · · · · · · 3-56
Error check · · · · · · · · · · · · · · · · · · · 8-1
Function Block Diagram · · · · · · · · · · · 6-15
Glossary · · · · · · · · · · · · · · · · · · · · A-4
Inserting elements · · · · · · · · · · · · · · 3-57
Inserting lines · · · · · · · · · · · · · · · · · 3-60
Jump instruction · · · · · · · · · · · · · · · 3-67
Keyboard commands · · · · · · · · · · · · B-14
Ladder Diagram· · · · · · · · · · · · · · · · 6-15
Macro· · · · · · · · · · · · · · · · · · · · · · 3-68
Moving elements · · · · · · · · · · · · · · · 3-59
Options· · · · · · · · · · · · · · · · · · · · · 3-55
Power bar · · · · · · · · · · · · · · · · · · · 3-54
Program elements · · · · · · · · · · · · · · 3-57
Recalculate lines · · · · · · · · · · · · · · · 3-61
Rubber banding · · · · · · · · · · · · · · · · 3-59
Selecting an element · · · · · · · · · · · · · 3-57
Selecting several elements · · · · · · · · · 3-58
Tools · · · · · · · · · · · · · · · · · · · · · · · C-3
User interface · · · · · · · · · · · · · · · · · 3-54
Variable configuration · · · · · · · · · · · · 3-63
Variable in user interface · · · · · · · · · · 3-54
Variables · · · · · · · · · · · · · · · · · · · · 3-71
Grid · · · · · · · · · · · · · · · · · · · · · · · · · 3-22
GSM modem settings
A-series · · · · · · · · · · · · · · · · · · · · 8-39
FX-series · · · · · · · · · · · · · · · · · · · 8-16
QnA-series · · · · · · · · · · · · · · · · · · 8-60
Q-series · · · · · · · · · · · · · · · · · · · · 8-67
Special remarks· · · · · · · · · · · · · · · · 8-82
Guided editing · · · · · · · · · · · · · · · · · · 7-10
Guided Ladder Editor
Auto Comment · · · · · · · · · · · · · · · · 7-26
Character Mode· · · · · · · · · · · · · · · · 7-23
Guided Editing · · · · · · · · · · · · · · · · 7-10
Guided Mode · · · · · · · · · · · · · · · · · · 7-2
Hotkeys · · · · · · · · · · · · · · · · · · · · 7-36
Ladder circuit printout · · · · · · · · · · · · 7-41
Ladder options · · · · · · · · · · · · · · · · 7-32
Variable name display · · · · · · · · · · · · 7-39
Guided Mode · · · · · · · · · · · · · · · · · · · · 7-2
GX Configurator-DP · · · · · · · · · · · · · · · 11-1
GX Developer ASCII file
Import · · · · · · · · · · · · · · · · · · · · · 8-120
GX IEC Developer ASCII file
Import · · · · · · · · · · · · · · · · · · · · · 8-118
GX Simulator · · · · · · · · · · · · · · · · · · · 9-94
H
Hardware requirements · · · · · · · · · · · · · · 2-1
Header · · · · · · · · · · · · · · · · · · · · · · · A-4
Error check · · · · · · · · · · · · · · · · · · · 8-1
Opening · · · · · · · · · · · · · · · · · · · · 3-33
Header monitor · · · · · · · · · · · · · · · · · · 9-66
I
I/O configuration · · · · · · · · · · · · · · · · · 5-40
Icon · · · · · · · · · · · · · · · · · · · · · · · · · 3-14
Identifier
Glossary · · · · · · · · · · · · · · · · · · · · A-4
Programming · · · · · · · · · · · · · · · · · · 6-6
Variable declaration · · · · · · · · · · · · · · 6-5
IEC address· · · · · · · · · · · · · · · · · · · · · 6-6
Ignore checks · · · · · · · · · · · · · · · · · · · 8-90
Import · · · · · · · · · · · · · · · · · · · 2-28, 8-118
File · · · · · · · · · · · · · · · · · · · · · · · · 4-2
GX Developer ASCII files · · · · · · · · · 8-120
GX IEC Developer ASCII files · · · · · · · 8-118
MELSEC Upload · · · · · · · · · · · · · · 8-123
Object· · · · · · · · · · · · · · · · · · · · · 8-119
Options· · · · · · · · · · · · · · · · · · · · · 2-28
Print files · · · · · · · · · · · · · · · · · · · 8-122
Project · · · · · · · · · · · · · · · · · · · · 8-118
IV
MITSUBISHI ELECTRIC
Index
In Cycle Monitor · · · · · · · · · · · · · · · · · 9-85
INI file · · · · · · · · · · · · · · · · · · · · · · · · 2-5
Initial value · · · · · · · · · · · · · · · · · · · · · 6-5
Initial Value · · · · · · · · · · · · · · · · · · · · · 6-9
Input
Graphical editor · · · · · · · · · · · · · · · · 3-63
Negation · · · · · · · · · · · · · · · · · · · · 3-63
Installation · · · · · · · · · · · · · · · · · · · · · 2-1
Instance · · · · · · · · · · · · · · · · · · · · · · 6-57
Glossary · · · · · · · · · · · · · · · · · · · · A-5
Multiple use · · · · · · · · · · · · · · · · · · 6-60
Instruction List · · · · · · · · · · · · · · · · · · · A-5
See Text editor
Intelligent Function Module Utility · · · · · · · 9-96
Interconnect mode · · · · · · · · · · · · · · · · 3-56
Interrupt settings · · · · · · · · · · · · · · · · · 5-67
Library · · · · · · · · · · · · · · · · · · · · · · · · 4-8
Glossary · · · · · · · · · · · · · · · · · · · · A-6
See also Manufacturer library
Pool · · · · · · · · · · · · · · · · · · · · · · · 4-3
See also Standard library
See also User library
Local DUT · · · · · · · · · · · · · · · · · · · · · 6-70
Local variable· · · · · · · · · · · · · · · · · · · · 6-5
Glossary · · · · · · · · · · · · · · · · · · · · A-6
J
Jump
Graphical editor · · · · · · · · · · · · · · · · 3-67
Sequential Function Chart· · · · · · · · · · 6-17
K
Keyboard
Selecting menu commands · · · · · · · · · · 3-3
Working in tables and editors · · · · · · · · 3-26
Keyboard commands · · · · · · · · · · · · · · · B-1
L
Label · · · · · · · · · · · · · · · · · · · · · · · · A-6
Absolute label · · · · · · · · · · · · · · · · 8-124
Network label · · · · · · · · · · · · · · · · · 3-42
System label limitation · · · · · · · · · · · · 3-42
Ladder Diagram
See also Graphical editor
Latch range · · · · · · · · · · · · · · · · · · · · 5-32
Latch Range· · · · · · · · · · · · · · · · · · · · 5-32
LD-Guided Mode · · · · · · · · · · · · · · · · · 2-29
LD-Variable Name · · · · · · · · · · · · · · · · 2-30
M
Macrocode execution · · · · · · · · · · · · · · 6-61
Option · · · · · · · · · · · · · · · · · · · · · 4-23
Manual SFC Control · · · · · · · · · · · · · · · 6-29
Manufacturer library · · · · · · · · · · · · · · · · 4-8
Glossary · · · · · · · · · · · · · · · · · · · · A-6
Programming instructions · · · · · · · · · · E-1
MC-MCR execution
Function block execution · · · · · · · · · · 6-61
Function block option· · · · · · · · · · · · · 4-23
Task · · · · · · · · · · · · · · · · · · · · · · · 6-2
MELSEC instructions · · · · · · · · · · · · · · · E-2
MELSECNET · · · · · · · · · · · · · · · · · · · 5-46
Memory parameters · · · · · · · · · · · · · · · 5-29
Menu bar · · · · · · · · · · · · · · · · · · · · · · 3-2
Menu commands · · · · · · · · · · · · · · · · · F-1
Keyboard commands · · · · · · · · · · · · · B-1
Menu Conventions · · · · · · · · · · · · · · · · · 3-2
MiniNet· · · · · · · · · · · · · · · · · · · · · · · 5-68
MITSUBISHI address · · · · · · · · · · · · · · · 6-6
Glossary · · · · · · · · · · · · · · · · · · · · A-6
MMP703.INI · · · · · · · · · · · · · · · · · · · · 2-5
Modem settings
analog modem · · · · · · · · · · · · · · · · 8-13
GSM modem · · · · · · · · · · · · · · · · · 8-16
Monitor Indication · · · · · · · · · · · · · · · · 2-31
Monitor Mode · · · · · · · · · · · · · · · · · · · 2-32
Monitoring · · · · · · · · · · · · · · · · · · · · · 9-60
Entry data monitor · · · · · · · · · · · · · · 9-66
Glossary · · · · · · · · · · · · · · · · · · · · A-6
Header monitor · · · · · · · · · · · · · · · · 9-66
In Cycle Monitor· · · · · · · · · · · · · · · · 9-85
Program monitor · · · · · · · · · · · · · · · 9-62
GX IEC Developer Reference Manual V
Index
Mouse
Selecting menu commands · · · · · · · · · · 3-3
Working in tables and editors · · · · · · · · 3-26
Multiple PLC settings · · · · · · · · · · · · · · 5-70
N
Navigator · · · · · · · · · · · · · · · · · · · · · · 3-4
Collapsing · · · · · · · · · · · · · · · · · · · · 3-6
Display levels · · · · · · · · · · · · · · · · · · 3-5
Displaying objects · · · · · · · · · · · · · · · 3-5
Editing objects · · · · · · · · · · · · · · · · 3-10
Expanding · · · · · · · · · · · · · · · · · · · · 3-5
Extended information · · · · · · · · · · · · · 3-6
Glossary · · · · · · · · · · · · · · · · · · · · A-8
Hide levels · · · · · · · · · · · · · · · · · · · 3-6
Keyboard commands · · · · · · · · · · · · · B-3
Levels · · · · · · · · · · · · · · · · · · · · · · 3-5
Project components · · · · · · · · · · · · · · 4-2
Tools · · · · · · · · · · · · · · · · · · · · · · · C-5
User interface · · · · · · · · · · · · · · · · · · 3-1
Network · · · · · · · · · · · · · · · · · · · · · · 6-13
Changing size · · · · · · · · · · · · · · · · · 3-42
Entering a new network · · · · · · · · · · · 3-41
Glossary · · · · · · · · · · · · · · · · · · · · A-6
MELSEC network in IEC IL · · · · · · · · · 6-14
MELSEC network in text editor · · · · · · · 3-46
Network label · · · · · · · · · · · · · · · · · 3-42
Network list · · · · · · · · · · · · · · · · · · 6-13
Network list insertion · · · · · · · · · · · · · 3-41
Network list managing · · · · · · · · · · · · 3-43
Network parameter · · · · · · · · · · · · · · 5-19
Network Diagnostics· · · · · · · · · · · · · · · · 9-7
Network Parameter · · · · · · · · · · · · · · · 5-19
Item List · · · · · · · · · · · · · · · · · · · · 5-23
O
Object · · · · · · · · · · · · · · · · · · · · · · · · 4-1
Call Tree · · · · · · · · · · · · · · · · · · · · 4-24
Close window · · · · · · · · · · · · · · · · · 3-14
Closing · · · · · · · · · · · · · · · · · · · · · 4-19
Comment · · · · · · · · · · · · · · · · · · · 4-21
Compiling · · · · · · · · · · · · · · · · · · · · 8-4
Copying · · · · · · · · · · · · · · · · · · · · 4-20
Creating · · · · · · · · · · · · · · · · · · · · 4-19
Cutting · · · · · · · · · · · · · · · · · · · · · 4-20
Deleting · · · · · · · · · · · · · · · · · · · · 4-20
Displaying in the navigator · · · · · · · · · · 3-5
Editing · · · · · · · · · · · · · · · · · · · · · 3-10
Error check · · · · · · · · · · · · · · · · · · · 8-1
Export· · · · · · · · · · · · · · · · · · · · · 8-116
Glossary · · · · · · · · · · · · · · · · · · · · A-7
Import · · · · · · · · · · · · · · · · · · · · · 8-119
Information · · · · · · · · · · · · · · · · · · 4-22
Open window · · · · · · · · · · · · · · · · · 3-13
Opening · · · · · · · · · · · · · · · · · · · · 4-19
Pasting · · · · · · · · · · · · · · · · · · · · · 4-20
Printing · · · · · · · · · · · · · · · · · · · · · 4-33
Reference List· · · · · · · · · · · · · · · · · 4-24
Renaming · · · · · · · · · · · · · · · · · · · 4-20
Saving · · · · · · · · · · · · · · · · · · · · · 4-19
Security level · · · · · · · · · · · · · · · · · 4-26
Subordinated objects · · · · · · · · · · · · 4-24
Superordinated objects · · · · · · · · · · · 4-24
User interface · · · · · · · · · · · · · · · · · · 3-5
Object window
Keyboard commands · · · · · · · · · · · · · B-5
Online
Changes in online mode · · · · · · · · · · 8-106
See also Monitoring
Opening
Body · · · · · · · · · · · · · · · · · · · · · · 3-40
Header · · · · · · · · · · · · · · · · · · · · · 3-33
Object · · · · · · · · · · · · · · · · · · · · · 3-13
Projects· · · · · · · · · · · · · · · · · · · · 10-15
Table · · · · · · · · · · · · · · · · · · · · · · 3-33
Window · · · · · · · · · · · · · · · · · · · · 3-13
VI
MITSUBISHI ELECTRIC
Index
Options· · · · · · · · · · · · · · · · · · · · · · · 2-20
Code Generation · · · · · · · · · · · · · · · 2-39
Compiler · · · · · · · · · · · · · · · · 2-44, 10-3
Cross Reference · · · · · · · · · · · · · · · 2-20
CSV-Export · · · · · · · · · · · · · · · · · · 2-21
Editing · · · · · · · · · · · · · · · · · · · · · 2-23
Export · · · · · · · · · · · · · · · · · · · · · 2-28
General · · · · · · · · · · · · · · · · · · · · 2-25
Graphic· · · · · · · · · · · · · · · · · · · · · 2-27
Import · · · · · · · · · · · · · · · · · · · · · 2-28
LD-Guided Mode · · · · · · · · · · · · · · · 2-29
Monitor Indication· · · · · · · · · · · · · · · 2-31
Monitor Mode · · · · · · · · · · · · · · · · · 2-32
Redundancy · · · · · · · · · · · · · · · · · · 2-48
Reset Devices· · · · · · · · · · · · · · · · · 2-50
ST Editor · · · · · · · · · · · · · · · · · · · · 2-33
System Variables · · · · · · · · · · · · · · · 2-51
Tooltips · · · · · · · · · · · · · · · · · · · · · 2-34
Transition Condition · · · · · · · · · · · · · 2-35
Variable Selection · · · · · · · · · · · · · · 2-36
Zoom Header/Body· · · · · · · · · · · · · · 2-37
Output
Graphical editor · · · · · · · · · · · · · · · · 3-64
Negation · · · · · · · · · · · · · · · · · · · · 3-64
Set/Reset · · · · · · · · · · · · · · · · · · · 3-64
P
Parameters · · · · · · · · · · · · · · · · · 5-1, 5-18
A · · · · · · · · · · · · · · · · · · · · · · · · 5-15
FX· · · · · · · · · · · · · · · · · · · · · · · · 5-16
Memory · · · · · · · · · · · · · · · · · · · · 5-29
Network · · · · · · · · · · · · · · · · · · · · 5-19
Q00J/Q00/Q01 · · · · · · · · · · · · · · · · 5-13
QnA· · · · · · · · · · · · · · · · · · · · · · · 5-14
QnH · · · · · · · · · · · · · · · · · · · · · · · 5-6
QnPH · · · · · · · · · · · · · · · · · · · · · · 5-8
QnPRH · · · · · · · · · · · · · · · · · · · · · 5-10
Redundant PLC · · · · · · · · · · · · · · · · 5-18
Remote I/O stations · · · · · · · · · · · · · 5-12
Transfer · · · · · · · · · · · · · · · · · · · · 8-83
PLC
Changing PLC type · · · · · · · · · · · 5-1, 5-18
Connecting PLC to PC · · · · · · · · · · · · 2-53
Redundancy Mode · · · · · · · · · · · · · · 3-20
Set time · · · · · · · · · · · · · · · · · · · · 9-59
Start/Stop function · · · · · · · · · · · · · · 9-57
Stop/Restart function· · · · · · · · · · · · · 9-58
PLC diagnostics · · · · · · · · · · · · · · · · · · 9-2
PLC keyword · · · · · · · · · · · · · · · · · · · 4-27
PLC Parameter
Item List · · · · · · · · · · · · · · · · · · · · · 5-6
Reading · · · · · · · · · · · · · · · · · · · · 5-17
PLC Setup · · · · · · · · · · · · · · · · · · · · · 5-58
PLC System · · · · · · · · · · · · · · · · · · · · 5-38
PLC Time · · · · · · · · · · · · · · · · · · · · · 9-59
Pointer · · · · · · · · · · · · · · · · · · · · · · 8-124
Printer
Configuration · · · · · · · · · · · · · · · · · 4-33
Connection · · · · · · · · · · · · · · · · · · 2-69
Printing· · · · · · · · · · · · · · · · · · · · · · · 4-33
File · · · · · · · · · · · · · · · · · · · · · · · · 4-2
Options· · · · · · · · · · · · · · · · · · · · · 4-34
Program· · · · · · · · · · · · · · · · · · · · · · · A-7
Program monitor · · · · · · · · · · · · · · · · · 9-62
Program organisation unit · · · · · · · · · · · · 4-6
Creating · · · · · · · · · · · · · · · · · · · · 4-19
Glossary · · · · · · · · · · · · · · · · · · · · A-8
Information · · · · · · · · · · · · · · · · · · 4-23
Pool · · · · · · · · · · · · · · · · · · · · · · · 4-5
Programming instruction
Assigning variables· · · · · · · · · · · · · · 3-71
EN/ENO · · · · · · · · · · · · · · · · · · · · · E-4
EN/ENO connection · · · · · · · · · · · · · 3-65
Glossary · · · · · · · · · · · · · · · · · · · · A-8
Library · · · · · · · · · · · · · · · · · · · · · · E-1
MELSEC · · · · · · · · · · · · · · · · · · · · E-2
Selection · · · · · · · · · · · · · · · · · · · · 3-69
Programming language · · · · · · · · · · · · · 6-13
See also Editors
GX IEC Developer Reference Manual VII
Index
Project · · · · · · · · · · · · · · · · · · · · · · · · 4-1
Backup · · · · · · · · · · · · · · · · · · · · · 4-17
Closing · · · · · · · · · · · · · · · · · · · · · 4-15
Compiling · · · · · · · · · · · · · · · · · · · · 8-3
Compiling status · · · · · · · · · · · · · · · · 4-5
Copying · · · · · · · · · · · · · · · · · · · · 4-16
Creating · · · · · · · · · · · · · · · · · · · · 4-12
Deleting · · · · · · · · · · · · · · · · · · · · 4-16
Error check · · · · · · · · · · · · · · · · · · · 8-1
Export· · · · · · · · · · · · · · · · · · · · · 8-116
Glossary · · · · · · · · · · · · · · · · · · · · A-8
Import · · · · · · · · · · · · · · · · · · · · · 8-118
Opening · · · · · · · · · · · · · · · · · · · · 4-14
Password · · · · · · · · · · · · · · · · · · · 4-25
Printing · · · · · · · · · · · · · · · · · · · · · 4-33
Recovering · · · · · · · · · · · · · · · · · · 4-14
Renaming · · · · · · · · · · · · · · · · · · · 4-16
Reorganizing · · · · · · · · · · · · · · · · · 4-18
Restore Backup · · · · · · · · · · · · · · · · 4-18
Saving · · · · · · · · · · · · · · · · · · · · · 4-15
Security level · · · · · · · · · · · · · · · · · 4-25
Transfer · · · · · · · · · · · · · · · · · · · · 8-99
Transfer setup· · · · · · · · · · · · · · · · · · 8-5
Using Backup · · · · · · · · · · · · · · · · · 4-14
Verify · · · · · · · · · · · · · · · · · · · · · · 4-49
Project specific options · · · · · · · · · · · · · 2-38
Projects of older versions · · · · · · · · · · · · 10-1
Protection · · · · · · · · · · · · · · · · · · · · · 4-25
Disable · · · · · · · · · · · · · · · · · · · · · 4-28
Enable · · · · · · · · · · · · · · · · · · · · · 4-28
Object · · · · · · · · · · · · · · · · · · · · · 4-26
PLC program · · · · · · · · · · · · · · · · · 4-27
Project · · · · · · · · · · · · · · · · · · · · · 4-25
User library · · · · · · · · · · · · · · · · · · 4-10
Q
Quitting GX IEC Developer · · · · · · · · · · · · 2-4
R
Redo · · · · · · · · · · · · · · · · · · · · · · · · 3-27
Redundancy· · · · · · · · · · · · · · · · · · · · 2-48
information · · · · · · · · · · · · · · · 2-48, 3-11
Redundancy Mode · · · · · · · · · · · · · · · · 3-20
Redundant Systems
Backup Mode · · · · · · · · · · · · · · · · · 3-17
System Switching· · · · · · · · · · · · · · · 9-61
Tracking Variables · · · · · · · · · · · · · · 9-82
Reference List · · · · · · · · · · · · · · · · · · 4-24
Remark · · · · · · · · · · · · · · · · · · · · · · · 6-9
Variable declaration · · · · · · · · · · · · · · 6-5
Replacing data · · · · · · · · · · · · · · · · · · 3-27
Reset Devices · · · · · · · · · · · · · · · · · · 2-50
Resource · · · · · · · · · · · · · · · · · · · · · · 4-1
Resume start · · · · · · · · · · · · · · · · · · · 6-19
Return instruction
Graphical editor · · · · · · · · · · · · · · · · 3-67
S
Scope · · · · · · · · · · · · · · · · · · · · · · · 3-71
Screen display
Customizing · · · · · · · · · · · · · · · · · · 3-22
Fonts · · · · · · · · · · · · · · · · · · · · · · 3-23
Saving · · · · · · · · · · · · · · · · · · · · · 3-24
Zoom factor · · · · · · · · · · · · · · · · · · 3-22
Scrollbar · · · · · · · · · · · · · · · · · · · · · · 3-22
Searching data · · · · · · · · · · · · · · · · · · 3-27
Select mode · · · · · · · · · · · · · · · · · · · · 3-56
Sequential Function Chart · · · · · · · · · · · 6-16
Action· · · · · · · · · · · · · · · · · · · · · · 6-16
Assigning action to step · · · · · · · · · · · 6-25
Assigning transition condition · · · · · · · · 6-26
Branching · · · · · · · · · · · · · · · · · · · 6-17
Comment · · · · · · · · · · · · · · · · · · · · 3-7
Glossary · · · · · · · · · · · · · · · · · · · · A-9
Initial step · · · · · · · · · · · · · · · · · · · 6-16
Jump · · · · · · · · · · · · · · · · · · · · · · 6-17
Jump exit/entry · · · · · · · · · · · · · · · · 6-23
Keyboard commands · · · · · · · · · · · · B-17
Macro step· · · · · · · · · · · · · · · · · · · 6-16
Programming · · · · · · · · · · · · · · · · · 6-19
Sequence errors · · · · · · · · · · · · · · · 6-30
Sequence rules · · · · · · · · · · · · · · · · 6-21
Step· · · · · · · · · · · · · · · · · · · · · · · 6-16
Tools · · · · · · · · · · · · · · · · · · · · · · · C-4
Transition · · · · · · · · · · · · · · · · · · · 6-16
Zooming · · · · · · · · · · · · · · · · · · · · 6-24
VIII
MITSUBISHI ELECTRIC
Index
Serial · · · · · · · · · · · · · · · · · · · · · · · · 5-71
SFC
Active information table · · · · · · · · · · · 6-19
Programming · · · · · · · · · · · · · · · · · 6-19
Resume start · · · · · · · · · · · · · · · · · 6-19
SFC Raster Elements · · · · · · · · · · · · · · 6-24
Show MELSEC code · · · · · · · · · · · · · · · 8-2
Software Requirements · · · · · · · · · · · · · · 2-1
ST Editor· · · · · · · · · · · · · · · · · · · · · · 2-33
Standard library · · · · · · · · · · · · · · · · · · 4-8
Glossary · · · · · · · · · · · · · · · · · · · · A-9
Programming instructions · · · · · · · · · · E-1
Starting GX IEC Developer · · · · · · · · · · · · 2-4
Menu bar · · · · · · · · · · · · · · · · · · · · 3-2
Status bar · · · · · · · · · · · · · · · · · · · · · 3-11
Configuration · · · · · · · · · · · · · · · · · 3-11
Customising · · · · · · · · · · · · · · · · · · 3-22
Default setting · · · · · · · · · · · · · · · · · 3-12
Glossary · · · · · · · · · · · · · · · · · · · · A-9
MMP703.INI· · · · · · · · · · · · · · · · · · · 2-7
User interface · · · · · · · · · · · · · · · · · · 3-1
Symbolic information
Download · · · · · · · · · · · · · · · · · · · 8-89
Import/Export · · · · · · · · · · · · · · · · · 4-31
Protection · · · · · · · · · · · · · · · · · · · 4-29
System label
Glossary · · · · · · · · · · · · · · · · · · · · A-9
Limitation · · · · · · · · · · · · · · · · · · · 3-42
T
Table · · · · · · · · · · · · · · · · · · · · · · · · 3-33
Column width · · · · · · · · · · · · · · · · · 3-35
Dialogue box · · · · · · · · · · · · · · · · · 3-35
Editing · · · · · · · · · · · · · · · · · · · · · 3-34
Inserting a new line · · · · · · · · · · · · · · 3-35
Keyboard commands · · · · · · · · · · · · · B-7
List box · · · · · · · · · · · · · · · · · · · · · 3-35
Opening · · · · · · · · · · · · · · · · · · · · 3-33
Selecting a line · · · · · · · · · · · · · · · · 3-34
Selecting cells· · · · · · · · · · · · · · · · · 3-34
Selecting several lines · · · · · · · · · · · · 3-34
Sorting entries · · · · · · · · · · · · · · · · 3-36
Task · · · · · · · · · · · · · · · · · · · · · · · · · 6-1
Creating · · · · · · · · · · · · · · · · · · · · 4-19
Glossary · · · · · · · · · · · · · · · · · · · · A-9
Information · · · · · · · · · · · · · · · · · · 4-24
MC-MCR · · · · · · · · · · · · · · · · · · · · 6-2
Pool · · · · · · · · · · · · · · · · · · · · · · · 4-4
Text editor · · · · · · · · · · · · · · · · · · · · · 3-45
Accumulator · · · · · · · · · · · · · · · · · · 6-14
Column width · · · · · · · · · · · · · · · · · 3-53
Comment · · · · · · · · · · · · · · · · · · · 3-46
Comment entering · · · · · · · · · · · · · · 3-53
Editing mode · · · · · · · · · · · · · · · · · 3-53
Error check · · · · · · · · · · · · · · · · · · · 8-1
Glossary · · · · · · · · · · · · · · · · · · · · A-9
Instruction List · · · · · · · · · · · · · · · · 6-14
Keyboard commands · · · · · · · · · · · · B-12
MELSEC Instruction List· · · · · · · · · · · 6-14
Programming instruction· · · · · · · · · · · 3-69
Programming languages · · · · · · · · · · 6-14
Structured Text · · · · · · · · · · · · · · · · 6-14
Tools · · · · · · · · · · · · · · · · · · · · · · · C-2
Variable · · · · · · · · · · · · · · · · · · · · 3-71
Timer
Extended timer · · · · · · · · · · · · · · · · 5-32
In function · · · · · · · · · · · · · · · · · · · 6-51
In function block· · · · · · · · · · · · · · · · 6-55
Latch range · · · · · · · · · · · · · · · · · · 5-32
Local timer · · · · · · · · · · · · · · · · · · · 6-75
Programming · · · · · · · · · · · · · · · · · 6-74
Timer function · · · · · · · · · · · · · · · · · 6-74
Timer function block · · · · · · · · · · · · · 6-75
Toggle · · · · · · · · · · · · · · · · · · · · · · · · 3-7
Toolbar · · · · · · · · · · · · · · · · · · · · · · · 3-4
Customising · · · · · · · · · · · · · · · · · · 3-22
User interface · · · · · · · · · · · · · · · · · · 3-1
Tools · · · · · · · · · · · · · · · · · · · · · · · · C-1
Graphical editor · · · · · · · · · · · · · · · · 3-57
Transfer · · · · · · · · · · · · · · · · · · · · · · · 8-5
Comparing projects · · · · · · · · · · · · · 8-104
Configuring communications port · · · · · · 8-5
Import · · · · · · · · · · · · · · · · · · · · · 8-118
Keyboard commands · · · · · · · · · · · · B-19
Online changes · · · · · · · · · · · · · · · 8-106
Ports (MMP703.INI) · · · · · · · · · · · · · · 2-8
Setup · · · · · · · · · · · · · · · · · · · · · · 8-83
Transition Condition · · · · · · · · · · · · · · · 2-35
GX IEC Developer Reference Manual IX
Index
U
Undo · · · · · · · · · · · · · · · · · · · · · · · · 3-27
USB
Installation · · · · · · · · · · · · · · · · · · · 2-68
USB driver · · · · · · · · · · · · · · · · · · · · · 2-71
User library · · · · · · · · · · · · · · · · · · · · · 4-8
Browsing · · · · · · · · · · · · · · · · · · · · 4-11
Creating · · · · · · · · · · · · · · · · · · · · · 4-9
Deleting · · · · · · · · · · · · · · · · · · · · 4-10
File · · · · · · · · · · · · · · · · · · · · · · · · 4-2
Glossary · · · · · · · · · · · · · · · · · · · · A-10
MMP703.INI· · · · · · · · · · · · · · · · · · · 2-7
Password · · · · · · · · · · · · · · · · · · · 4-10
Removing · · · · · · · · · · · · · · · · · · · 4-10
Updating · · · · · · · · · · · · · · · · · · · · 4-10
W
Window · · · · · · · · · · · · · · · · · · · · · · 3-13
Arranging · · · · · · · · · · · · · · · · · · · 3-14
Changing display size · · · · · · · · · · · · 3-14
Closing · · · · · · · · · · · · · · · · · · · · · 3-14
Icons · · · · · · · · · · · · · · · · · · · · · · 3-14
Opening · · · · · · · · · · · · · · · · · · · · 3-13
Selecting · · · · · · · · · · · · · · · · · · · · 3-13
Wizard · · · · · · · · · · · · · · · · · · · · · · · 4-13
Glossary · · · · · · · · · · · · · · · · · · · · A-10
MMP703.INI· · · · · · · · · · · · · · · · · · · 2-9
Workspace
Loading · · · · · · · · · · · · · · · · · · · · 3-24
Saving · · · · · · · · · · · · · · · · · · · · · 3-24
V
Variable · · · · · · · · · · · · · · · · · · · · · · · 6-5
Declaration · · · · · · · · · · · · · · · · · · · 6-5
Export · · · · · · · · · · · · · · · · · · · · · 2-21
Global variable · · · · · · · · · · · · · · · · · 4-4
Glossary · · · · · · · · · · · · · · · · · · · · A-10
Graphical editor · · · · · · · · · · · · · · · · 3-63
Local variable · · · · · · · · · · · · · · · · · 2-45
Names· · · · · · · · · · · · · · · · · · 2-45, 10-4
Text editor · · · · · · · · · · · · · · · · · · · 3-45
User interface · · · · · · · · · · · · · · · · · 3-71
Verify · · · · · · · · · · · · · · · · · · · · · · · · 4-49
Verify differences
Keyboard commands · · · · · · · · · · · · · B-9
Z
Zooming · · · · · · · · · · · · · · · · · · · · · · 2-37
X
MITSUBISHI ELECTRIC