Lithonia Lighting Contractor Select LBL4 LED Wrap offers energy-efficient lighting for commercial and industrial applications. Its durable construction and high-performance LEDs provide long-lasting, reliable illumination. With its versatile design, the LBL4 LED Wrap can be used for a variety of tasks, including general area lighting, task lighting, and accent lighting. It's ideal for use in warehouses, factories, gymnasiums, and other large spaces.
تبلیغات
تبلیغات
LBL4/LBL8 LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
•
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
•
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
•
Installation and service of luminaires should be performed by a qualified licensed electrician .
• Maintenance of the luminaires should be performed by person(s) familiar with the luminaires ’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
•
It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
•
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
•
Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov
.
• These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered su fficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
✓ Disconnect or turn off power before
RISK OF ELECTRIC SHOCK installation or servicing.
✓ Verify that supply voltage is correct by comparing it with the luminaire label information.
✓ Make all electrical and grounded connections in accordance with the National
Electrical Code (NEC) and any applicable local code requirements.
✓ All wiring connections should be capped with UL approved recognized wire connectors.
WARNING
RISK OF BURN
✓ Allow lamp/fixture to cool before handling.
Do not touch enclosure or light source.
✓ Do not exceed maximum wattage marked on luminaire label.
✓ Follow all manufacturer’s warni ngs, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION
RISK OF INJURY
✓ Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
✓ Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF FIRE
✓ Keep combustible and other materials that can burn, away from lamp/lens.
✓ Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
Page 1 of 7
UT459805 Rev. B
LBL4/LBL8 LED IMPORTANT SAFETY INSTRUCTIONS
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
CAUTION: RISK OF PRODUCT DAMAGE
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be powered directly off a switched circuit.
Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
Only use fixture in its intended location.
LED products are Polarity Sensitive. Ensure proper Polarity before installation.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
✓ Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and
Conditions, please visit www.acuitybrands.com.
Our Brands Daylighting
SunOptics
Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC
Light Concepts
Indoor Lighting
Gotham
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting
Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen
Controls
DARK TO LIGHT
LC&D
ROAM
Sensor Switch
Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
Page 2 of 7
UT459805 Rev. B
LBL4/LBL8 LED IMPORTANT SAFETY INSTRUCTIONS
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION
CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT
AND THE HAZARDS INVOLVED
Installation Instructions
**Caution: MAKE SURE LUMINAIRE IS MOUNTED TO A SECURE STRUCTURE. USE APPROPRIATE MOUNTING
HARDWARE TO INSTALL FIXTURE RATED FOR YOUR APPLICATION. FAILURE TO MOUNT FIXTURE CORRECTLY
COULD RESULT IN SERIOUS INJURY.
KEEP THESE INSTALLATION INSTRUCTIONS / CONSERVEZ CES INSTRUCTIONS D'INSTALLATION
❶
A: Remove diffuser from housing by sliding diffuser to one side, then lift up opposite side over flange as shown.
B: Remove wireway from housing by squeezing sideway to disengage from retaining slots.
Page 3 of 7
UT459805 Rev. B
❷
LBL4/LBL8 LED IMPORTANT SAFETY INSTRUCTIONS
A: Remove knockout from center of fixture housing as shown.
B: With power off, lift fixture housing to ceiling, centering knockout over outlet box and parallel to walls. Mark ceiling with pencil for mounting holes through (2) 1/4" x 3/8" slots. Drill 1/8" pilot hole at each location (if drill did not encounter ceiling joist, enlarge hole in ceiling to accommodate toggle bolt).
❸
A: With power off, hold fixture up to outlet box and pull wires into fixture housing through the knockout hole.
B: Secure fixture housing at each end to ceiling with #10 wood screws or toggle bolts, depending on structural conditions.
Page 4 of 7
UT459805 Rev. B
❹
LBL4/LBL8 LED IMPORTANT SAFETY INSTRUCTIONS
A. With power off, insert the black and white supply wires securely into the yellow plug-in driver connector (black to black, white to white). Attach ground wire to green ground screw.
B. Replace wireway cover tabs in fixture housing (make sure no wiring is pinched under cover).
Battery Wiring (option)
UT459805 Rev. B
Figure 1: PS1055LCP Wiring Diagram
Page 5 of 7
LBL4/LBL8 LED IMPORTANT SAFETY INSTRUCTIONS
Figure 2: EL7L/14L Wiring Diagram
Sensor Wiring (option)
UT459805 Rev. B
Figure 3: LSXR10 Wiring Diagram
Page 6 of 7
LBL4/LBL8 LED IMPORTANT SAFETY INSTRUCTIONS
Figure 4: LSXRHL Wiring Diagram
Step Level Device Wiring (option)
UT459805 Rev. B
Figure 5: SLD Wiring Diagram