Lithonia Lighting D-Series Surface Canopy is a versatile and durable outdoor lighting solution, suitable for various applications. It features a sturdy construction with a hinged design that allows for easy installation and maintenance. The canopy provides a wide range of light distribution options, making it ideal for illuminating pathways, entrances, and other outdoor areas. With its energy-efficient LED technology, the D-Series Surface Canopy offers long-lasting performance and significant energy savings compared to traditional lighting fixtures.
Reklama
Reklama
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
· To reduce the risk of death, personal injury or property damage from fi re, electric shock, falling parts, cuts/ abrasions, and other hazards please read all warnings and instructions included with and on the fi xture box and all fi xture labels.
· Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
· Installation and service of luminaires should be performed by a qualifi ed licensed electrician.
· Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fi xture maintenance programs are recommended.
· It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.
Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
· DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confi rm. Any part damaged or broken during or after assembly should be replaced.
· Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov
.
· These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered suffi ciently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
Disconnect or turn off power before installation or servicing.
Verify that supply voltage is correct by comparing it with the luminaire label information.
Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
All wiring connections should be capped with UL approved recognized wire connectors.
WARNING
RISK OF BURN
Allow lamp/fi xture to cool before handling. Do not touch enclosure or light source.
Do not exceed maximum wattage marked on luminaire label.
Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION
RISK OF INJURY
Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF FIRE
Keep combustible and other materials that can burn, away from lamp/lens.
Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
Never connect components under load.
Do not mount or support these fi xtures in a manner that can cut the outer jacket or damage wire insula on.
Unless individual product speci fi ca ons deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, ming devices, or other related control devices. LED fi xtures must be powered directly o ff a switched circuit.
Unless individual product speci fi ca ons deem otherwise: Do not restrict fi xture ven la on. Allow for some volume of airspace around fi xture. Avoid covering LED fi xtures with insula on, foam, or other material that will prevent convec on or conduc on cooling.
Unless individual product speci fi ca ons deem otherwise: Do not exceed fi xtures maximum ambient temperature.
Only use fi xture in its intended loca on.
LED products are Polarity Sensi ve. Ensure proper Polarity before installa on.
Electrosta c Discharge (ESD): ESD can damage LED fi xtures. Personal grounding equipment must be worn during all installa on or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
Some components inside the fi xture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representa ve for assistance.
Always read the fi xtures complete installa on instruc ons prior to installa on for any addi onal fi xture speci fi c warnings.
Please see product specifi c installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Our Brands
Lithonia Lighting Gotham American Electric Lighting
RELOC Renaissance Ligh ng Tersen
DARK TO LIGHT SunOptics
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
Installation Instructions
D-Series LED Surface Canopy
DELIVERY: Upon receipt of fi xture and accessories (packed separately), thoroughly inspect for any freight damage. All damage should be reported to the delivery carrier. Compare the catalog description listed on the packing slip with the fi xture label on the inside of the housing to be sure you have received the correct merchandise.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Tools Required: 5/16" nut driver or socket, 7/16" socket, electrical wiring tools
Over tightening will cause stripping and void all warranties.
5 year limited warranty
SURFACE MOUNTING INSTALLATION:
Note: do not set fi xture down on lens on unprotected surface.
1. Remove fi xture from packaging, review fi xture labels for warnings and electrical connection information. fi g a
FIXTURE HINGE SIDE
2. Back out captive screws on the top of the fi xture. Remove the j-box mounting plate (fi g b).
T5W/T5M/T5E
3. Orient the j-box plate according to the label (fi g a).
Housing side mounting plate (Factory Installed) J-box mounting plate fi g b
T5R ASY
LIGHT THROW DIRECTION
Captive screws
4. Use 25 in. Lb. Torque to properly secure the junction box plate to the j-box (fi g c) with (2) two 10-
24 screws (by others).
5. Align the tabs from the junction box plate with the slots in the mounting plate on the housing.
6. Hang the DSXSC fi xture on the junction box mounting plate (fi g d).
7. Connect fi xture wires to appropriate voltage supply wires using proper sized connectors. (Supply side ground wire to green fi xture lead--supply side neutral wire to white fi xture lead--supply side line voltage to black fi xture lead.)
8. Ensure that wires are not being pinched and tuck into junction box.
9. Lift the fi xture upwards mating the 2 plates and retighten the captive screws from step 2.
Junction box
(by others)
Junction box mounting plate fi g c fi g d
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 800-279-8041 • Fax: 770.918.1209 • www.lithonia.com
© 2011 Acuity Brands Lighting, Inc. All rights reserved.
Part Number: RJ521352 Rev C
Revision Date: 11-18-13
Installation Instructions
D-Series LED Surface Canopy
BIRD DETERRENT SHIELD (BDS option)--option ships seperately
Note: If motion sensor option is installed, you must remove knock out on the bird shield.
BDS w/Surface Mount
DSXSCBDSSJ (fi nish) U
Surface Mount
For use with surface mounted j-box.
Not for use with recessed j-box.
1. Install fi xture per supplied instructions.
2. Take BDS and wrap it around fi xture, use caution not to over-bend BDS wrap. Make sure to align the slots on the wrap with the hinges on the DSXSC housing.
3. Install the 10-24 screws provided.
Troubleshooting: If this fi xture fails to operate properly, check to make sure: • The fi xture is wired correctly. • The fi xture is grounded correctly. • The line voltage at the fi xture is correct. If all these variables have been checked and the fi xture still does not operate as specifi ed, contact your local Lithonia Lighting distributor.
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 800-279-8041 • Fax: 770.918.1209 • www.lithonia.com
© 2011 Acuity Brands Lighting, Inc. All rights reserved. Rev 9/12
Part Number: RJ521352 Rev C
Revision Date: 11-18-13
Stáhnout